The advance facilities like, MOODY

INTERNATIONAL
014

Hot Oil Spraying System for gradual cooling of transformer coils. ISO 9001 : 2008

Hot Air Vacuum (HAV) Drying Plant / Vacuum Drying Plant


ISO Static pressing for transformer coils.

Transformer Oil Purification Plant

Vacuum Impregnation Plant


Casting Resin

Features: Resin Casting Plant


1. Useful Volume- 20 m3 upto 300 m3
2. Fully automatic Plant, equipped with PLC, SCADA, Data Logger & Trends. Electrostatic oil cleaner
3. Available in Manual Mode also. (CDOC)
4. Oil Filling / Oil Impregnation System inside Autoclave under Vacuum
5. Facilities like Oil Spray Cooling & Isostatic Pressing. Drying Ovens
6. Trolley Loading by Electrical Winch, Chain Conveyor, Manual
Vacuum Ovens
Applications:
1. Vacuum Drying of Transformer Coils. Uni - Vac Oil Dehydration Unit
2. Dehydration of Capacitors, Winding & Electrical Components.
3. Drying of Transformer Tanks & Oil Filling. Capacitor Impregnation Plant

Sf6 Gas Purification Plant

Authorised Representative
* In view of continuous development, we reserve the right modify the design & / or dimension without notice

REGD. OFFICE & WORKS :


PLOT NO. 81-B/16,
GENERAL BLOCK,
M.I.D.C., BHOSARI,
PUNE 411 026
MAHARASHTRA
(INDIA).

TEL.:
+91 (020) 2712 6253 ( Hunting 4Lines)
FAX :
+91(020) 2712 2399.
E-mail :
ceedeevacuum@vsnl.com
WEB :
www.ceedeevacuum.net

IN COLLABORATION

Mica ac MOODY
Vacuum Technology INTERNATIONAL
014
AN ISO 9001:2008 CERTIFIED COMPANY

w w w . c e e d e e v a c u u m . n e t
INTERNAL HOT AIR CIRCULATION
DRYING PLANT FOR ELECTRICAL PART:
The Internal hot air circulation for Drying plant chamber is calculated
More and more, today's electrical and electronic industries are looking toward 100% on internal volume of the system. This is achieved by utilizing a
performance of instrument. Although much has been done over the years to improve tailored fan(blower) and scroll arrangement which directs the air into
vacuum drying technology for electrical parts. the heating ducts and over the heating tubes to ensure to efficient heat
transfer. The airflow is deflected around the internal wall face. To flow
WHY VDP? over the component to the center of the vessel into the eye of the fan.
The vacuum drying chamber will be useful for drying the active chamber part of In a continuous cycle giving a repeatedly moving 3D controlled air flow.
transformers. During drying, the moisture absorbed by the transformer winding & insulation
paper will be extracted by the vacuum pumping system. It will be possible that the
transformer coils are dried completely and condensation will be reduced to negligible level

Vacuum by the end of the drying cycle.

INSULATION VOIDS are eliminated through the use of the VDP process. Voids may
contain moisture, dust or other contaminants, which lead to shortened insulation life. Voids
are common place for corona to occur in high voltage applications. The VDP process is

Drying best means of the obtaining a void free system.

PREMATURE THERMAL AGING is greatly reduced by the excellent heat transfer


properties offered VDP system. Small air pockets in coils, or between coils and core iron,
reduce heat transfer. Heat that cannot escape from the coil to the iron will greatly decrease
OIL STORAGE TANKS
Oil storage tank are divided in two parts.

Plant the life of the transformer winding.

VIBRATION is practically eliminated with VDP. An energized coil will move and cause
abrasion of insulation unless securely anchored. It is therefore, logical and proven fact
that the best VDP improved performance life expectancy to electric motors, generator,
1. R.O.S.T (Raw Oil Storage Tank)
R.O.S.T is provided with oil indicator, level indicator, centrifugal pump, ball valve.
The raw oil to the shop floor is stored before processing. The interconnection pipeline is
made in between filter plant and R.O.S.T.
transformer etc.
Loading & Handling System: 2. P.O.S.T. (Process Oil Storage Tank)
Vacuum drying plant can be provided with rails fitting accommodate loading trolleys for P.O.S.T is provided with heating arrangement controlled by thyristor thermostat. The
movement of job. Trolley can be moved automatically/manually depending on the load and electric heating is wired equally on three group with continuity to secure to phase failure.
the customer demand. Heating systems help the process oil to maintain at particular temperature. Before use, The
P.O.S.T is also connected vacuum system with condenser in between, the degassing
MAJOR COMPONENTS OF
v column provided on the P.O.S.T helps to store oil free of gas. The pump provided with the
VACUUM (VDP) SYSTEM P.O.S.T help to circulate oil through the degassing column on the P.O.S.T

The Vacuum system is normally provided


with roots rotary combination. Cascading
with condenser oil chilling system, water OIL FILTER MACHINE
reserve tank and condenser in-between.
Fully programmable variable vacuum The oil treatment stations work on the principle of high vacuum low temperature. The system
system can be added as an option to is provided with the roots rotary combination. The raw oil from the R.O.S.T (Raw Oil Storage
enable the vacuum system to increase and Tank) is treated purified through the system and store in P.O.S.T (Process Oil Storage Tank)
decrease the vacuum level at different point
during drying process. The water reserve
tank is constructed in stainless steel. The
temperature of the same is controlled by
thermostat providing the chilling system. On demand, chilling system can be provided with
stand by compressor unit.
OIL FILLING SYSTEM
The most essential equipment HEATING SYSTEM
v
The oil filling in instrument transformer, distribution transformer, power transformer can
be achieved under vacuum. Various sensors, oil totaliser can be provided as an
for every transformer industry. The electric heating can also be offered by
accessories to fill oil under vacuum with majored quantity. The sight glass provided on
way of thermostat/thyristor control
elements arranged. The total heating the system help to monitor the status inside the chamber during process.
Being highly essential process banks are connected through three
independent bus bars to ensure uniformity
Vacuum drying is the largest investment and continued operation in case of phase Control Panel
failure. The heater banks are mounted “CEE DEE” Provides dedicated control panel systems with an option of independent programmer and
and is required to be done precisely. around inside of the vessel placed controller interface to a computer based monitoring package (SCADA). For ease of data input curve
between the air duct and the internal profile generation (Graph), data analysis of curve profiles. Data logger, password protection on
as improper activity may lead to cladding and insulation. Heating system optionally provided as oil fired/ gas fired oil different levels (Manager Level, Supervisor level, Worker level etc) Controller can also be provided
heating systems. The tubes are circulated inside the Drying plant equally through which with web connectivity which help to transmit data to long distance PC,R pt. temperature recorder,
insulation failure. the hot oil is passed. The temperature of hot oil is controlled 120°-150° C. vacuum recorder, process recorder etc. with colour inkjet print can also be provided on customer
demand.

You might also like