You are on page 1of 2

Counter Current

FT01 FT02 Hot Water Hot Water Cold Water Cold Water
(LPM) (LPM) Inlet TT03 Outlet TT04 Inlet TT05 Outlet TT06
(C) (C) (C) (C)
1 0.7 50 46 24 29.8
1 1 49.8 45.4 24 27.8
1 1.3 49.3 44.9 24.1 27
1.5 0.7 49.8 46.7 24.1 30.4
1.5 1 49.87 46.2 24.2 28.7
1.5 1.3 49.8 46 24.2 27.8

Data Shell and Tube Heat Exchanger

Diameter luar tube : 6 mm = 6 x 10-3 m

Panjang tube : 163 mm = 163 x 10-3m

Jumlah tube : 7

Sifat Fisik Air

Massa jenis air dingin = 995,85 kg/m3

Massa jenis air panas = 988,05 kg/m3

Panas spesifik air = 4200 j/kg C

3.1 Menghitung Efisiensi Perpindahan Panas

Qc
Efisiensi = = mc x C p x¿ ¿ ¿
Qh

a. Laju Alir Massa


- Laju Alir Massa Air Panas (mh)
mh = 𝜌×𝑉
kg Liter 1 m3 1menit
mh = 988,05 x1 x x
m3 menit 1000 Liter 60 detik
mh = 0.0165 kg/s
- Laju Alir Massa Air Dingin (mc)
mc = 𝜌×𝑉
kg Liter 1 m3 1menit
mc = 995,85 x1 x x
m3 menit 1000 Liter 60 detik
mc = 0.0216 kg/s
b. Laju Perpindahan Panas
- Laju Perpindahan Panas Air Panas (Qh)
Qh = mh x C p x ¿¿
Qh = 0,0165 kg/s x 4200 J/kg°C x (50 – 24) °C
Qh = 277,2 J/s = 277,2 W
- Laju Perpindahan Panas Air Dingin (Qc)
Q c = mc x C p x¿ ¿
Q c = 0,0216 kg/s x 4200 J/kg°C x (29,8 – 24) °C
Q c = 526,176 J/s = 526,176 W

c. Efisiensi
Qc
= mc x C p x¿ ¿ ¿
Qh
Q c 526,176
= = 1,89 = 189%
Qh 277,2