You are on page 1of 457

Indoor unit

(R410A)
0CVP0-03& (Replaces 0CVP0-03%)

P/No. : MFL61741620
Indoor unit

• Introduction
• General Information
• Indoor Units
• Dip Switch & Group Control Setting
Introduction
1. Preface

General information
R410A Model

Indoor unit
is the most favored choice when there is a need for precise air conditioning of relatively big pro-
jects extending from Multi-Room structure to big commercial places. We have a big line up, that offers wider
flexibility of model selection.

Equipped with inverter technology and long piping installation, the product matches well if one talk about opti-
mum power consumption in high rise buildings. Add on capacity feature makes it easy to upgrade the existing
capacity at any time.

With the growing concern about environment preservation, comes with R410A refrigerant which
is environment friendly and thus our system is a high technology and environment friendly prod-
uct.

Unique refrigerant flow and electronic circuit control gives this system an unique capability to work in
extreme/abnormal working conditions making our customer feel great about their decision of selecting
LG as their first choice.

This publication provides a detailed and in depth information about the design and installation of
.

We hope that with this information you would become an expert of your system.

Air Conditioning & Energy Solution Company


2. Step by Step System Selection Process
General Information

(1) Calculate or obtain the maximum heat load for the area(s) to be air conditioned

(2) Decide the indoor unit specifications

Decide the outdoor unit specifications

Capacity coefficient factor

Decide the air velocity and temperature distributions

(3)
Selection of refrigerant pipe joints and headers

(4)
Selection of the control system

Control wiring method

Description of devices

(5) Electrical wiring

Electric characteristics

Field wiring

! Caution
1. Air conditioners should not be installed in areas where corrosive gas such as acid gas
or alkaline gas is produced.

2. If the outdoor unit is installed close to the sea shore, direct exposure to the sea breeze
should be avoided and choose an outdoor unit with anti-corrosion treatment.
Indoor unit
General Information
1. Model Names

2. External Appearance

3. Nomenclature

4. Indoor Unit Capacity Index


1. Model Names
Capacity(Btu/h(kW))
Chassis
Category
General information

Name 5k 7k 9k 12k 15k 18k 21k 24k 28k 36k 42k 48k 54k 76k 96k
(1.6) (2.2) (2.8) (3.6) (4.5) (5.6) (6.2) (7.1) (8.2) (10.6) (12.3) (14.1) (15.8) (22.4) (28.0)
● ● ● ●
Indoor unit

SB O
Wall Mounted Libero
SC ● ●
SE ● ● ● ●
Mirror
ART COOL S8 ● ●
Gallery SF O O O
TU ● ● ●
1 Way
TT ● ●
2 Way TL ● ●
Ceiling TR O ● ● ●
Cassette TQ ● ●
4 Way TP ● ●
TN ●
TM ● ●
BH ● ● ● ● ● ●
BG O O O O ● ● ●
High Static
BR O O O ● ●
B8 ● ●
Ceiling B1 ● ● ● ●
Concealed B2 ● ●
Duct Low Static L1 O ● ●
L2 ● ● ●
L3 O ●
Built In B3 ● ● ● ●
(Low Static) B4 ● ●
Ceiling & Floor VE ● ●
VJ ● ●
Ceiling Suspended VK ●
VL ●
CE O ● ● ●
With Case
Floor CF ● ●
Standing Without CE O ● ● ●
Case CF ● ●
Console QA O O O O
BR O
Fresh Air Intake Unit
B8 O O

h In matters of combination with Outdoor unit system, refer the PDB of that outdoor units.
h : can not be combined with Multi V III Solo system.
h O : can be combined with EHP(Multi V series) only.
h ●: can be combined with EHP(Multi V series) or GHP.

1 _ General Information
2. External Appearance

Ceiling Cassette- 1Way Ceiling Concealed Duct - High Static

General information
ARNU07GTU*2 ARNU07GBHA2 ARNU36GBGA2
ARNU09GTU*2 ARNU09GBHA2 ARNU42GBGA2

Indoor unit
ARNU12GBHA2 ARNU48GBRA2
ARNU12GTU*2
ARNU15GBHA2 ARNU54GBRA2
ARNU18GBHA2 ARNU76GB8A2
ARNU24GBHA2 ARNU96GB8A2
ARNU18GTT*2 ARNU28GBGA2
ARNU24GTT*2 * A:Basic, C:Plasma ARNU12GBGA2 ARNU28GBRA2
ARNU15GBGA2 ARNU36GBRA2
Ceiling Cassette- 4Way ARNU18GBGA2
ARNU24GBGA2
ARNU42GBRA2
ARNU05GTR*2 ARNU24GTP*2
ARNU07GTR*2 ARNU28GTP*2
ARNU09GTR*2 ARNU36GTN*2 Wall mounted (Libero)
ARNU12GTR*2 ARNU42GTM*2
ARNU15GTQ*2 ARNU48GTM*2 ARNU05GSB*2 ARNU15GSB*2
ARNU18GTQ*2 ARNU07GSB*2 ARNU18GSC*2
* A:Basic, C:Plasma ARNU09GSB*2 ARNU24GSC*2
ARNU12GSB*2 * A:Basic, L:Plasma
Ceiling Concealed Duct - Low Static
ARNU07GB1G2 ARNU15GB1G2
ARNU09GB1G2 ARNU18GB2G2
ARNU12GB1G2 ARNU24GB2G2
ART COOL Gallery
ARNU07GSF*2
ARNU05GL1G2 ARNU15GL2G2 ARNU09GSF*2
ARNU07GL1G2 ARNU18GL2G2 ARNU12GSF*2
ARNU09GL1G2 ARNU21GL3G2 * E:Red V:Silver
ARNU12GL2G2 ARNU24GL3G2 G:Gold 1: Kiss (Photo changeable)

Ceiling Concealed Duct – Built-in (Low Static)


ARNU07GB3G2 ARNU15GB3G2
Floor Standing
ARNU09GB3G2 ARNU18GB4G2 With case
ARNU12GB3G2 ARNU24GB4G2 ARNU07GCEA2 ARNU15GCEA2
ARNU09GCEA2 ARNU18GCFA2
ARNU12GCEA2 ARNU24GCFA2
ART COOL Mirror Without case
ARNU07GSE*2 ARNU15GSE*2
ARNU09GSE*2 ARNU18GS8*2 ARNU07GCEU2 ARNU15GCEU2
ARNU12GSE*2 ARNU24GS8*2 ARNU09GCEU2 ARNU18GCFU2
ARNU12GCEU2 ARNU24GCFU2
* R:Mirror, V:Silver

Ceiling & Floor


ARNU09GVEA2 Console
ARNU12GVEA2 ARNU07GQAA2
ARNU09GQAA2
Ceiling Suspended ARNU12GQAA2
URNU18GVJA2 URNU36GVKA2 ARNU15GQAA2
URNU24GVJA2 URNU48GVLA2

Ceiling Cassette -2Way Fresh Air Intake Unit


ARNU18GTL*2 ARNU48GBRZ2
ARNU24GTL*2 ARNU76GB8Z2
ARNU96GB8Z2

* A:Basic, C:Plasma
h In matters of combination with Outdoor unit system, refer the PDB of that outdoor units.
h Indoor Units bigger than 54k and Fresh Air Intake Units can not be combined with Multi V III Solo system.

General Information _ 2
3. Nomenclature

ARN U 07 G TU A 2
General information

Serial Number
Indoor unit

Combinations of functions
A:Basic function
L:Neo Plasma(Wall Mounted)
C:Plasma(Ceiling Cassette)
G: Low Static
U : Floor Standing without Case
ART COOL Type Panel Color
SE/S8 - R:Mirror V:Silver
SF - E:Red V:Silver G:Gold 1: Kiss (Photo changeable)
Q : Console
Z : Fresh Air Intake Unit

Chassis Name

Electrical Ratings
2:1Ø, 220V, 60Hz
6:1Ø, 220 - 240V, 50Hz
G:1Ø, 220 - 240V, 50Hz / 1Ø, 220V, 60Hz

Total Cooling Capacity in Btu/h


EX) 5,000 Btu/h Class ➝ '05' 18,000 Btu/h Class ➝ '18'

Combination of Inverter Type and


Cooling Only or Heat Pump
N: AC Inverter and H/P V: AC Inverter and C/O
U: DC Inverter and H/P and C/O

System with
Indoor Unit using R410A

3 _ General Information
4. Indoor Unit Capacity Index
Indoor unit capacity index

General information
Unit Capacity
5k 7k 9k 12k 15k 18k 21k 24k 28k 36k 42k 48k 54k 76k 96k
(Btu/h)

Indoor unit
Capacity
1.6 2.2 2.8 3.6 4.5 5.6 6.2 7.1 8.2 10.6 12.3 14.1 15.8 22.4 28.0
Index

h Capacity Index is same as the capacity(kW).


h In matters of combination with Outdoor unit system, refer the PDB of that outdoor units.
h Indoor Units bigger than 54k and Fresh Air Intake Units can not be combined with Multi V III Solo system.

General Information _ 4
Indoor unit
Ceiling Cassette 1-Way
Ceiling Cassette 2-Way
Ceiling Cassette 4-way
Ceiling Concealed Duct(High Static)
Ceiling Concealed Duct(High Static)(2)
Ceiling Concealed Duct(Low Static)
Ceiling Concealed Duct(Built in (Low Static))
Wall Mounted (Libero)
ART COOL Mirror
ART COOL Gallery
Ceiling & Floor/Ceiling Suspended
Floor Standing
Console
Fresh Air Intake Unit
Indoor unit
Ceiling Cassette 1-Way
1. List of functions

2. Specifications

3. Dimensions

4. Piping Diagrams

5. Wiring Diagrams

6. Capacity Tables

7. Air Velocity and Temperature Distribution

8. Electric Characteristics

9. Sound Levels

10. Installation

11. Accessories
1. List of functions
ARNU07GTU*2, ARNU09GTU*2, ARNU12GTU*2
Category Function
ARNU18GTT*2, ARNU24GTT*2
Air supply outlet 1
Airflow direction control(left & right) -
Airflow direction control(up & down) Auto
Auto swing(left & right) -
Auto swing(up & down) O
Air flow
Airflow steps(fan/cool/heat) 4/5/4
Chaos swing X
Chaos wind(auto wind) O
Jet cool(Power wind) O
Swirl wind -
Deodorizing filter X
Air purifying Plasma air purifier Option
Prefilter(washable / anti-fungus) O
Drain pump O
E.S.P. control X
Installation
Electric heater(operation) X

Indoor Units
High ceiling operation O
Hot start O
Reliability Self diagnosis O
Soft dry operation O
Auto changeover O(Heat recovery)
Auto cleaning X
Auto operation(artificial intelligence) O(Heat pump or Cooling only)
Auto restart operation O
Child lock O
Convenience Forced operation O
Group control O
Sleep mode O
Timer(on/off) O
Timer(weekly) O
Two thermistor control O
Wide wired remote controller PQRCVSL0/PQRCVSL0QW
Deluxe wired remote controller X
Individual
Simple wired remote controller PQRCVCL0Q(W)
control
Wired remote controller(for hotel use) PQRCHCA0Q(W)
Wireless LCD remote control PQWRH(C)Q0FDB
Zone control -
CTIE -
Special Electro thermostat -
function kit Remote temperature sensor PQRSTA0
Group control wire PZCWRCG3
Dry contact PQDSA(1)/PQDSB(1)/PQDSBC/PQDSBNGCM1/PQDSBCGCD0

O : Applied X : Not applied – : No relation


Option : Model name & price are different according to options, and assembled in factory with main unit.
Accessory : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate
package.
* Some functions can be limited by remote controller.

Ceiling Cassette 1-Way _ 1


2. Specifications
* Model Name
A:Basic, C:Plasma
Type 1Way Ceiling Cassette
Model Unit ARNU07GTU*2 ARNU09GTU*2 ARNU12GTU*2
kW 2.2 2.8 3.6
Cooling Capacity kcal/h 1,900 2,400 3,100
Btu/h 7,500 9,600 12,300
kW 2.5 3.2 4.0
Heating Capacity kcal/h 2,200 2,800 3,400
Btu/h 8,500 10,900 13,600
Casing Galvanized Steel Plate Galvanized Steel Plate Galvanized Steel Plate
mm 860 x 132 x 450 860 x 132 x 450 860 x 132 x 450
Body
inch 33-27/32 x 5-3/16 x 17-23/32 33-27/32 x 5-3/16 x 17-23/32 33-27/32 x 5-3/16 x 17-23/32
Dimensions (WxHxD)
mm 1,100 x 34 x 500 1,100 x 34 x 500 1,100 x 34 x 500
Front Panel
inch 43-5/16 x 1-11/32 x 19-11/16 43-5/16 x 1-11/32 x 19-11/16 43-5/16 x 1-11/32 x 19-11/16
Coil Rows x Columns x FPI 2 x 12 x 18 2 x 12 x 18 2 x 12 x 18
Face Area m2 0.16 0.16 0.16
Type Cross Flow Fan Cross Flow Fan Cross Flow Fan
Indoor Units

Motor Output x Number W 30 30 30


Running Current A 0.18 0.18 0.18
Fan Air Flow Rate(H / M / L) CMM 8.2 / 7.3 / 6.4 9.2 / 8.6 / 8.2 10 / 9.2 / 8.2
cfm 289.5 / 257.7 / 225.9 324.7 / 303.6 / 289.5 353 / 324.8 / 289.5
Drive Direct Direct Direct
Motor type BLDC BLDC BLDC
Temperature Control Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating
Sound Absorbing Thermal Insulation Material Foamed polystrene Foamed polystrene Foamed polystrene
Safety Device Fuse Fuse Fuse
Liquid Side mm(inch) Ø6.35(1/4) Ø6.35(1/4) Ø6.35(1/4)
Pipe Connections Gas Side mm(inch) Ø12.7(1/2) Ø12.7(1/2) Ø12.7(1/2)
Drain Pipe(Internal Dia.) mm(inch) 25(1) 25(1) 25(1)
Net Weight Body kg(lbs) 14.7(32.4) 14.7(32.4) 14.7(32.4)
Noise Level(Sound Press, 1.5m, H / M / L) dB(A) 32 / 29 / 25 35 / 34 / 32 38 / 35 / 32
Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50
1, 220, 60 1, 220, 60 1, 220, 60
Refrigerant Control EEV EEV EEV
Power cable CV1.5 x 3C CV1.5 x 3C CV1.5 x 3C
Transmission cable CVV-SB 1.0~1.5 x 2C CVV-SB 1.0~1.5 x 2C CVV-SB 1.0~1.5 x 2C
Panel Color White White White
Panel Name(Accessory) PT-UUC(Grill), PT-UUD(Panel)

Notes:- Conversion Formula


1. Capacities are based on the following conditions:
Cooling • Indoor temp. 27°C[80.6°F]DB/ 19°C[66.2°F]WB kcal/h= kW x 860
• Outdoor temp. 35°C[95°F]DB/ 24°C[75.2°F]WB Btu/h = kW x 3412
• Interconnecting Piping Length 7.5m cfm = m3/min x 35.3
• Level Difference of Zero l/s = CMM x 1000/60
Heating • Indoor temp. 20°C[68°F]DB/ 15°C[59°F]WB
• Outdoor temp. 7°C[44.6°F]DB/ 6°C[42.8°F]WB
• Interconnecting Piping Length 7.5m
• Level Difference of Zero
2. Capacities are Net Capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve
6. Anechoic chamber conversion value is measured at 1.5 m downward from unit centre.
The values depends on the ambient conditions and values are normally higher in actual operation.

2 _ Ceiling Cassette 1-Way


2. Specifications
* Model Name
A:Basic, C:Plasma
Type 1Way Ceiling Cassette
Model Unit ARNU18GTT*2 ARNU24GTT*2
kW 5.6 7.1
Cooling Capacity kcal/h 4,800 6,100
Btu/h 19,100 24,200
kW 6.3 7.1
Heating Capacity kcal/h 5,400 6,100
Btu/h 21,500 24,200
Casing Galvanized Steel Plate Galvanized Steel Plate
mm 1,180 x 132 x 450 1,180 x 132 x 450
Body
inch 46-15/32 x 5-3/16 x 17-23/32 46-15/32 x 5-3/16 x 17-23/32
Dimensions (WxHxD)
mm 1,420 x 34 x 500 1,420 x 34 x 500
Front Panel
inch 55-29/32 x 1-11/32 x 19-11/16 55-29/32 x 1-11/32 x 19-11/16
Coil Rows x Columns x FPI 2 x 12 x 18 2 x 12 x 18
Face Area m2 0.24 0.24
Type Cross Flow Fan Cross Flow Fan

Indoor Units
Motor Output x Number W 30 30
Running Current A 0.30 0.30
Fan Air Flow Rate(H / M / L) CMM 13.3 / 12.1 / 10.9 14.6 / 13.3 / 11.5
cfm 515.4 / 427.1 / 384.8 575.4 / 469.5 / 406
Drive Direct Direct
Motor type BLDC BLDC
Temperature Control Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating
Sound Absorbing Thermal Insulation Material Foamed polystrene Foamed polystrene
Safety Device Fuse Fuse
Liquid Side mm(inch) Ø6.35(1/4) Ø9.52(3/8)
Pipe Connections Gas Side mm(inch) Ø12.7(1/2) Ø15.88(5/8)
Drain Pipe(Internal Dia.) mm(inch) 25(1) 25(1)
Net Weight Body kg(lbs) 18.7(41.23) 18.7(41.23)
Noise Level(Sound Press, 1.5m, H / M / L) dB(A) 40 / 37 / 35 43 / 40 / 36
Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50
1, 220, 60 1, 220, 60
Refrigerant Control EEV EEV
Power cable CV1.5 x 3C CV1.5 x 3C
Transmission cable CVV-SB 1.0~1.5 x 2C CVV-SB 1.0~1.5 x 2C
Panel Color White White
Panel Name(Accessory) PT-UTC(Grill), PT-UTD(Panel)

Notes:- Conversion Formula


1. Capacities are based on the following conditions:
Cooling • Indoor temp. 27°C[80.6°F]DB/ 19°C[66.2°F]WB kcal/h= kW x 860
• Outdoor temp. 35°C[95°F]DB/ 24°C[75.2°F]WB Btu/h = kW x 3412
• Interconnecting Piping Length 7.5m cfm = m3/min x 35.3
• Level Difference of Zero l/s = CMM x 1000/60
Heating • Indoor temp. 20°C[68°F]DB/ 15°C[59°F]WB
• Outdoor temp. 7°C[44.6°F]DB/ 6°C[42.8°F]WB
• Interconnecting Piping Length 7.5m
• Level Difference of Zero
2. Capacities are Net Capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve
6. Anechoic chamber conversion value is measured at 1.5 m downward from unit centre.
The values depends on the ambient conditions and values are normally higher in actual operation.

Ceiling Cassette 1-Way _ 3


Indoor Units

Ceiling Cassette 1-way

ARNU07GTU*2
ARNU09GTU*2
1 ARNU12GTU*2
2
3. Dimensions

(unit : mm)

275.8
206.6
Number Name Descripition

4 _ Ceiling Cassette 1-Way


106.8
860 88 1 Liquid pipe connection Unit size(7k, 9k, 12k):ø6.35
1012 2 Gas pipe connection Unit size(7k, 9k, 12k):ø12.7
450
320.5 27
3 Air suction grill
4 Air discharge grill

Note

132
168.3

96.5
1. Unit should be installed in compliance with the installation manual

57.4
in the product box.
2. Unit shall be grounded in accordance with the local regulations or
1,100 applicable national codes.
(Panel Name: PT-UUC)
881(Air outlet Hole)

500
3

34

76, Seongsan-dong, Changwon City, Gyeongnam,


641-713, Korea CHASSIS CODE: TU
Ceiling Cassette 1-way
ARNU07GTU*2
1 ARNU09GTU*2
2 ARNU12GTU*2

354.3
275.8
206.3
106.8
3. Dimensions

(unit : mm)
860 88
Number Name Descripition
1012
1 Liquid pipe connection Unit size(7k, 9k, 12k):ø6.35
450 2 Gas pipe connection Unit size(7k, 9k, 12k):ø12.7
320.5 27
3 Air suction grill
4 Air discharge grill

168.3
132
96.5
Note

57.4
1. Unit should be installed in compliance with the installation manual
in the product box.

1100
2. Unit shall be grounded in accordance with the local regulations or
applicable national codes.
109.5 (Panel Name: PT-UUD)

46.5
4

500
3

34
117

76, Seongsan-dong, Changwon City, Gyeongnam,


641-713, Korea CHASSIS CODE: TU

Ceiling Cassette 1-Way _ 5


Indoor Units
Indoor Units

Ceiling Cassette 1-way

ARNU18GTT*2
ARNU24GTT*2
2

1
3. Dimensions

(unit : mm)

247.5
Number Name Descripition

6 _ Ceiling Cassette 1-Way


180.6
1 Liquid pipe connection Unit size(18k):ø6.35, (24k):ø9.52

65.3
2 Gas pipe connection Unit size(18k):ø12.7, (24k):ø15.88
1180 65.1
1332 450 3 Air suction grill
4 Air discharge grill

Note
1. Unit should be installed in compliance with the installation manual

173.8
132

91
96.1
in the product box.
2. Unit shall be grounded in accordance with the local regulations or

31.7
20.6 57.4
applicable national codes.

1,420 (Panel Name: PT-UTC)


1,201(Air Outlet Hole)

500
3

34

76, Seongsan-dong, Changwon City, Gyeongnam,


641-713, Korea CHASSIS CODE: TT
Ceiling Cassette 1-way
ARNU18GTT*2
ARNU24GTT*2
2
1

247.5
180.6
3. Dimensions

(unit : mm)
1180 65.1
Number Name Descripition

65.3
1332 1 Liquid pipe connection Unit size(18k):ø6.35, (24k):ø9.52
2 Gas pipe connection Unit size(18k):ø12.7, (24k):ø15.88
3 Air suction grill
450
4 Air discharge grill
22.3 335 96.5

Note
1. Unit should be installed in compliance with the installation manual

173.8
132

91
97.1
57
in the product box.
Ø14
2. Unit shall be grounded in accordance with the local regulations or

57.4
31.7
15.2

20.6
applicable national codes.

1420 (Panel Name: PT-UTD)


109.5

46.5
4

500
3
44

34
76, Seongsan-dong, Changwon City, Gyeongnam,
641-713, Korea CHASSIS CODE: TT

Ceiling Cassette 1-Way _ 7


Indoor Units
4. Piping Diagrams

:Cooling
Heat Exchanger EEV :Heating
Filter
Th3 Th2
C.F.F.
Filter

Th1 lndoor unit


Indoor Units

Refrigerant pipe connection port diameter

[Unit: mm(inch)]

Model Gas Liquid

ARNU07GTU*2

ARNU09GTU*2
Ø12.7(1/2) Ø6.35(1/4)
ARNU12GTU*2

ARNU18GTT*2

ARNU24GTT*2 Ø15.88(5/8) Ø9.52(3/8)

LOC. Description
Th1 Room thermistor
Th2 Pipe in thermistor
Th3 Pipe out thermistor

8 _ Ceiling Cassette 1-Way


5. Wiring Diagrams
TU, TT Chassis

Indoor Units
CONNECTOR NUMBER LOCATION POINT FUNCTION
CN-MOTOR1 Fan motor output Motor output of BLDC
CN-D/PUMP Drain pump output AC output for drain pump
CN-485 Communication Connection between indoor and outdoor
CN-DISP Display Display of indoor status
CN-EEV EEV Output EEV Control output
CN-VANE2 Step motor Step motor output
CN-FLOAT Float switch input Float switch sensing
CN-PIPE/IN Suction pipe sensor Pipe in thermistor
CN-PIPE/OUT Discharge pipe sensor Pipe out thermistor
CN-ROOM Room sensor Room air thermistor
CN-REMO Remote controller Remote control line
CN-CC Dry contact Dry contact line
CN-OPTION Option pwb. Communication between main and option
CN-COM Communication Communication between indoor and outdoor
CN-VANE1 Step motor Step motor output

Dip Switch Setting Off On Remarks


SW3 GROUP Master Slave Group Control setting using Wired Remote Controller
Old Dry Contact Mode Setting
1. Variable : Auto/Manual Mode can be chosen by Wide wired
SW4 DRY CONTACT Variable Auto remote controller or Wireless remote controller
(When shipped from Factory → Manual Mode)
2. Auto : For Dry Contact, it is always Auto mode.
1. Duct model
-. OFF : Default(not operate continuosly )
-. ON : Fan operate continuosly
SW5 EXTRA 1 Off On 2. Cassette Model : No Function
3. Ceiling Suspended Model
-. OFF : Ceiling(default)
-. ON : Floor

CAUTION
For Multi V Model, Dip Switch 1,2,6,7,8 must be set OFF
That dip switch is used for the other model.

Ceiling Cassette 1-Way _ 9


6. Capacity Tables
6.1 Cooling Capacity Cooling capacity

Indoor air temp. (DB/WB, °C)


Indoor Units

Capacity Outdoor 20 23 26 27 28 30 32
Index air temp. 14 16 18 19 20 22 24
(DB, °C) TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10 1.5 1.3 1.8 1.4 2.0 1.6 2.2 1.6 2.4 1.7 2.6 1.7 2.9 1.7
12 1.5 1.3 1.8 1.4 2.0 1.6 2.2 1.6 2.4 1.7 2.6 1.7 2.9 1.7
14 1.5 1.3 1.8 1.4 2.0 1.6 2.2 1.6 2.4 1.7 2.6 1.7 2.8 1.7
16 1.5 1.3 1.8 1.4 2.0 1.6 2.2 1.6 2.4 1.7 2.6 1.7 2.8 1.6
18 1.5 1.3 1.8 1.4 2.0 1.6 2.2 1.6 2.4 1.7 2.6 1.7 2.7 1.6
20 1.5 1.3 1.8 1.4 2.0 1.6 2.2 1.6 2.4 1.7 2.6 1.7 2.7 1.6
21 1.5 1.3 1.8 1.4 2.0 1.6 2.2 1.6 2.4 1.7 2.6 1.7 2.7 1.6
23 1.5 1.3 1.8 1.4 2.0 1.6 2.2 1.6 2.4 1.7 2.6 1.7 2.6 1.6
2.2 25 1.5 1.3 1.8 1.4 2.0 1.6 2.2 1.6 2.4 1.7 2.6 1.7 2.6 1.5
27 1.5 1.3 1.8 1.4 2.0 1.6 2.2 1.6 2.4 1.7 2.5 1.7 2.6 1.5
Indoor Units

29 1.5 1.3 1.8 1.4 2.0 1.6 2.2 1.6 2.4 1.7 2.5 1.6 2.5 1.5
31 1.5 1.3 1.8 1.4 2.0 1.6 2.2 1.6 2.4 1.7 2.5 1.6 2.5 1.5
33 1.5 1.3 1.8 1.4 2.0 1.6 2.2 1.6 2.4 1.7 2.4 1.6 2.4 1.4
35 1.5 1.3 1.8 1.4 2.0 1.6 2.2 1.6 2.4 1.7 2.4 1.6 2.4 1.4
37 1.5 1.3 1.8 1.4 2.0 1.6 2.2 1.6 2.3 1.6 2.3 1.5 2.4 1.4
39 1.5 1.3 1.8 1.4 2.0 1.6 2.2 1.6 2.2 1.6 2.3 1.5 2.4 1.4
10 1.9 1.6 2.2 1.8 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.7 2.1
12 1.9 1.6 2.2 1.8 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.6 2.1
14 1.9 1.6 2.2 1.8 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.6 2.1
16 1.9 1.6 2.2 1.8 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.5 2.0
18 1.9 1.6 2.2 1.8 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.5 2.0
20 1.9 1.6 2.2 1.8 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.4 2.0
21 1.9 1.6 2.2 1.8 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.4 2.0
23 1.9 1.6 2.2 1.8 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.4 2.0
2.8 25 1.9 1.6 2.2 1.8 2.6 2.0 2.8 2.0 3.0 2.1 3.3 2.1 3.3 1.9
27 1.9 1.6 2.2 1.8 2.6 2.0 2.8 2.0 3.0 2.1 3.2 2.1 3.3 1.9
29 1.9 1.6 2.2 1.8 2.6 2.0 2.8 2.0 3.0 2.1 3.2 2.0 3.2 1.9
31 1.9 1.6 2.2 1.8 2.6 2.0 2.8 2.0 3.0 2.1 3.2 2.0 3.2 1.8
33 1.9 1.6 2.2 1.8 2.6 2.0 2.8 2.0 3.0 2.1 3.1 2.0 3.1 1.8
35 1.9 1.6 2.2 1.8 2.6 2.0 2.8 2.0 3.0 2.1 3.0 2.0 3.1 1.8
37 1.9 1.6 2.2 1.8 2.6 2.0 2.8 2.0 2.9 2.0 3.0 1.9 3.0 1.8
39 1.9 1.6 2.2 1.8 2.6 2.0 2.8 2.0 2.8 2.0 2.9 1.9 3.0 1.7
10 2.4 2.1 2.9 2.3 3.3 2.5 3.6 2.6 3.9 2.7 4.3 2.8 4.7 2.8
12 2.4 2.1 2.9 2.3 3.3 2.5 3.6 2.6 3.9 2.7 4.3 2.8 4.7 2.8
14 2.4 2.1 2.9 2.3 3.3 2.5 3.6 2.6 3.9 2.7 4.3 2.8 4.6 2.7
16 2.4 2.1 2.9 2.3 3.3 2.5 3.6 2.6 3.9 2.7 4.3 2.8 4.6 2.7
18 2.4 2.1 2.9 2.3 3.3 2.5 3.6 2.6 3.9 2.7 4.3 2.8 4.5 2.7
20 2.4 2.1 2.9 2.3 3.3 2.5 3.6 2.6 3.9 2.7 4.3 2.8 4.4 2.6
21 2.4 2.1 2.9 2.3 3.3 2.5 3.6 2.6 3.9 2.7 4.3 2.8 4.4 2.6
23 2.4 2.1 2.9 2.3 3.3 2.5 3.6 2.6 3.9 2.7 4.3 2.8 4.3 2.5
3.6 25 2.4 2.1 2.9 2.3 3.3 2.5 3.6 2.6 3.9 2.7 4.3 2.8 4.3 2.5
27 2.4 2.1 2.9 2.3 3.3 2.5 3.6 2.6 3.9 2.7 4.2 2.7 4.2 2.5
29 2.4 2.1 2.9 2.3 3.3 2.5 3.6 2.6 3.9 2.7 4.1 2.7 4.2 2.4
31 2.4 2.1 2.9 2.3 3.3 2.5 3.6 2.6 3.9 2.7 4.1 2.6 4.1 2.4
33 2.4 2.1 2.9 2.3 3.3 2.5 3.6 2.6 3.9 2.7 4.0 2.6 4.0 2.3
35 2.4 2.1 2.9 2.3 3.3 2.5 3.6 2.6 3.9 2.7 3.9 2.5 4.0 2.3
37 2.4 2.1 2.9 2.3 3.3 2.5 3.6 2.6 3.8 2.6 3.8 2.5 3.9 2.3
39 2.4 2.1 2.9 2.3 3.3 2.5 3.6 2.6 3.7 2.5 3.8 2.4 3.9 2.2

10 _ Ceiling Cassette 1-Way


6. Capacity Tables

Cooling capacity

Indoor air temp. (DB/WB, °C)

Indoor Unit
Capacity Outdoor 20 23 26 27 28 30 32
Index air temp. 14 16 18 19 20 22 24
(DB, °C) TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10 3.8 3.2 4.5 3.5 5.2 3.8 5.6 3.9 6.0 4.1 6.7 4.2 7.3 4.1
12 3.8 3.2 4.5 3.5 5.2 3.8 5.6 3.9 6.0 4.1 6.7 4.2 7.3 4.1
14 3.8 3.2 4.5 3.5 5.2 3.8 5.6 3.9 6.0 4.1 6.7 4.2 7.2 4.1
16 3.8 3.2 4.5 3.5 5.2 3.8 5.6 3.9 6.0 4.1 6.7 4.2 7.1 4.0
18 3.8 3.2 4.5 3.5 5.2 3.8 5.6 3.9 6.0 4.1 6.7 4.2 6.9 4.0
20 3.8 3.2 4.5 3.5 5.2 3.8 5.6 3.9 6.0 4.1 6.7 4.2 6.9 3.9
21 3.8 3.2 4.5 3.5 5.2 3.8 5.6 3.9 6.0 4.1 6.7 4.2 6.9 3.9
23 3.8 3.2 4.5 3.5 5.2 3.8 5.6 3.9 6.0 4.1 6.7 4.2 6.7 3.8
5.6 25 3.8 3.2 4.5 3.5 5.2 3.8 5.6 3.9 6.0 4.1 6.6 4.1 6.6 3.7
27 3.8 3.2 4.5 3.5 5.2 3.8 5.6 3.9 6.0 4.1 6.5 4.1 6.5 3.7

Indoor Units
29 3.8 3.2 4.5 3.5 5.2 3.8 5.6 3.9 6.0 4.1 6.4 4.0 6.5 3.7
31 3.8 3.2 4.5 3.5 5.2 3.8 5.6 3.9 6.0 4.1 6.3 3.9 6.4 3.6
33 3.8 3.2 4.5 3.5 5.2 3.8 5.6 3.9 6.0 4.1 6.2 3.9 6.2 3.5
35 3.8 3.2 4.5 3.5 5.2 3.8 5.6 3.9 6.0 4.1 6.1 3.8 6.2 3.5
37 3.8 3.2 4.5 3.5 5.2 3.8 5.6 3.9 5.8 3.9 5.9 3.7 6.1 3.4
39 3.8 3.2 4.5 3.5 5.2 3.8 5.6 3.9 5.7 3.8 5.8 3.7 6.0 3.4
10 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.6 5.2 8.5 5.4 9.3 5.3
12 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.6 5.2 8.5 5.4 9.2 5.3
14 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.6 5.2 8.5 5.4 9.1 5.2
16 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.6 5.2 8.5 5.4 9.0 5.1
18 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.6 5.2 8.5 5.4 8.8 5.1
20 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.6 5.2 8.5 5.4 8.7 5.0
21 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.6 5.2 8.5 5.4 8.7 5.0
23 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.6 5.2 8.5 5.4 8.5 4.9
7.1 25 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.6 5.2 8.4 5.3 8.4 4.8
27 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.6 5.2 8.2 5.2 8.3 4.8
29 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.6 5.2 8.1 5.1 8.2 4.7
31 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.6 5.2 8.0 5.0 8.1 4.6
33 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.6 5.2 7.8 5.0 7.9 4.5
35 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.6 5.2 7.7 4.9 7.8 4.5
37 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.4 5.0 7.5 4.8 7.7 4.4
39 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.2 4.9 7.4 4.7 7.6 4.3

Notes:
TC: Total Capacity(kW), SHC: Sensible Heat Capacity(kW) 2. Refer to Capacity Correction Factor in the outdoor unit PDB for
1. Capacity tables show the representative value of conditions the actual performance data of each indoor unit and outdoor unit
which may occur. combination.

Ceiling Cassette 1-Way _ 11


6. Capacity Tables

6.2 Heating Capacity Heating capacity

Outdoor air Indoor air temp. (DB, °C)


Indoor Units

Capacity temp. 16 18 20 21 22 24
Index TC TC TC TC TC TC
DB(°C) WB(°C)
kW kW kW kW kW kW
-24.8 -25.0 1.4 1.4 1.4 1.4 1.4 1.4
-21.8 -22.0 1.7 1.7 1.7 1.7 1.7 1.7
-19.8 -20.0 1.8 1.8 1.8 1.8 1.8 1.8
-18.8 -19.0 1.9 1.9 1.9 1.9 1.9 1.9
-16.7 -17.0 2.0 2.0 2.0 2.0 2.0 2.0
-14.7 -15.0 2.1 2.1 2.1 2.1 2.1 2.0
-12.6 -13.0 2.2 2.2 2.2 2.2 2.1 2.1
-10.5 -11.0 2.3 2.3 2.2 2.2 2.2 2.2
-9.5 -10.0 2.3 2.3 2.3 2.3 2.3 2.2
-8.5 -9.1 2.3 2.3 2.3 2.3 2.3 2.2
-7.0 -7.6 2.4 2.4 2.4 2.4 2.3 2.2
2.2 -5.0 -5.6 2.5 2.5 2.5 2.4 2.3 2.2
-3.0 -3.7 2.6 2.6 2.5 2.4 2.3 2.2
0.0 -0.7 2.7 2.6 2.5 2.4 2.3 2.2
Indoor Units

3.0 2.2 2.7 2.7 2.5 2.4 2.3 2.2


5.0 4.1 2.8 2.7 2.5 2.4 2.3 2.2
7.0 6.0 2.8 2.7 2.5 2.4 2.3 2.2
9.0 7.9 2.8 2.7 2.5 2.4 2.3 2.2
11.0 9.8 2.8 2.7 2.5 2.4 2.3 2.2
13.0 11.8 2.8 2.7 2.5 2.4 2.3 2.2
15.0 13.7 2.8 2.7 2.5 2.4 2.3 2.2
-24.8 -25.0 1.9 1.9 1.8 1.8 1.8 1.8
-21.8 -22.0 2.2 2.2 2.2 2.2 2.2 2.2
-19.8 -20.0 2.4 2.4 2.3 2.3 2.3 2.3
-18.8 -19.0 2.4 2.4 2.4 2.4 2.4 2.4
-16.7 -17.0 2.5 2.5 2.5 2.5 2.5 2.5
-14.7 -15.0 2.7 2.7 2.6 2.6 2.6 2.6
-12.6 -13.0 2.8 2.8 2.8 2.8 2.7 2.7
-10.5 -11.0 2.9 2.9 2.9 2.9 2.9 2.8
-9.5 -10.0 3.0 3.0 2.9 2.9 2.9 2.8
-8.5 -9.1 3.0 3.0 3.0 3.0 3.0 2.8
2.8 -7.0 -7.6 3.1 3.1 3.1 3.1 3.0 2.8
-5.0 -5.6 3.2 3.2 3.2 3.1 3.0 2.8
-3.0 -3.7 3.4 3.3 3.2 3.1 3.0 2.8
0.0 -0.7 3.4 3.3 3.2 3.1 3.0 2.8
3.0 2.2 3.5 3.4 3.2 3.1 3.0 2.8
5.0 4.1 3.6 3.4 3.2 3.1 3.0 2.8
7.0 6.0 3.6 3.4 3.2 3.1 3.0 2.8
9.0 7.9 3.6 3.4 3.2 3.1 3.0 2.8
11.0 9.8 3.6 3.4 3.2 3.1 3.0 2.8
13.0 11.8 3.6 3.4 3.2 3.1 3.0 2.8
15.0 13.7 3.6 3.4 3.2 3.1 3.0 2.8
-24.8 -25.0 2.3 2.3 2.3 2.3 2.3 2.3
-21.8 -22.0 2.8 2.8 2.8 2.8 2.8 2.8
-19.8 -20.0 2.9 2.9 2.9 2.9 2.9 2.9
-18.8 -19.0 3.0 3.0 3.0 3.0 3.0 3.0
-16.7 -17.0 3.1 3.1 3.1 3.1 3.1 3.1
-14.7 -15.0 3.3 3.3 3.3 3.3 3.3 3.3
-12.6 -13.0 3.5 3.4 3.4 3.4 3.4 3.4
-10.5 -11.0 3.6 3.6 3.6 3.6 3.6 3.5
-9.5 -10.0 3.7 3.7 3.7 3.7 3.7 3.5
-8.5 -9.1 3.8 3.8 3.7 3.7 3.7 3.5
3.6 -7.0 -7.6 3.9 3.9 3.9 3.8 3.7 3.5
-5.0 -5.6 4.0 4.0 4.0 3.9 3.7 3.5
-3.0 -3.7 4.2 4.1 4.0 3.9 3.7 3.5
0.0 -0.7 4.3 4.1 4.0 3.9 3.7 3.5
3.0 2.2 4.4 4.3 4.0 3.9 3.7 3.5
5.0 4.1 4.5 4.3 4.0 3.9 3.7 3.5
7.0 6.0 4.5 4.3 4.0 3.9 3.7 3.5
9.0 7.9 4.5 4.3 4.0 3.9 3.7 3.5
11.0 9.8 4.5 4.3 4.0 3.9 3.7 3.5
13.0 11.8 4.5 4.3 4.0 3.9 3.7 3.5
15.0 13.7 4.5 4.3 4.0 3.9 3.7 3.5

12 _ Ceiling Cassette 1-Way


6. Capacity Tables

Heating capacity

Outdoor air Indoor air temp. (DB, °C)

Indoor Unit
Capacity temp. 16 18 20 21 22 24
Index TC TC TC TC TC TC
DB(°C) WB(°C)
kW kW kW kW kW kW
-24.8 -25.0 3.6 3.6 3.6 3.6 3.6 3.6
-21.8 -22.0 4.4 4.4 4.4 4.4 4.4 4.4
-19.8 -20.0 4.6 4.6 4.6 4.6 4.6 4.6
-18.8 -19.0 4.8 4.7 4.7 4.7 4.7 4.7
-16.7 -17.0 5.0 5.0 5.0 4.9 4.9 4.9
-14.7 -15.0 5.2 5.2 5.2 5.2 5.2 5.2
-12.6 -13.0 5.5 5.4 5.4 5.4 5.4 5.4
-10.5 -11.0 5.7 5.7 5.7 5.7 5.7 5.5
-9.5 -10.0 5.8 5.8 5.8 5.8 5.8 5.5
-8.5 -9.1 5.9 5.9 5.9 5.9 5.9 5.5
-7.0 -7.6 6.1 6.1 6.1 6.0 5.9 5.5
5.6 -5.0 -5.6 6.3 6.3 6.3 6.1 5.9 5.5
-3.0 -3.7 6.6 6.5 6.3 6.1 5.9 5.5
0.0 -0.7 6.7 6.5 6.3 6.1 5.9 5.5

Indoor Units
3.0 2.2 6.9 6.7 6.3 6.1 5.9 5.5
5.0 4.1 7.0 6.7 6.3 6.1 5.9 5.5
7.0 6.0 7.1 6.7 6.3 6.1 5.9 5.5
9.0 7.9 7.1 6.7 6.3 6.1 5.9 5.5
11.0 9.8 7.1 6.7 6.3 6.1 5.9 5.5
13.0 11.8 7.1 6.7 6.3 6.1 5.9 5.5
15.0 13.7 7.1 6.7 6.3 6.1 5.9 5.5
-24.8 -25.0 4.1 4.1 4.1 4.1 4.1 4.1
-21.8 -22.0 5.0 5.0 4.9 4.9 4.9 4.9
-19.8 -20.0 5.2 5.2 5.2 5.2 5.2 5.2
-18.8 -19.0 5.4 5.3 5.3 5.3 5.3 5.3
-16.7 -17.0 5.6 5.6 5.6 5.6 5.6 5.6
-14.7 -15.0 5.9 5.9 5.9 5.9 5.9 5.8
-12.6 -13.0 6.2 6.1 6.1 6.1 6.1 6.1
-10.5 -11.0 6.4 6.4 6.4 6.4 6.4 6.2
-9.5 -10.0 6.5 6.5 6.5 6.5 6.5 6.2
-8.5 -9.1 6.7 6.7 6.6 6.6 6.6 6.2
7.1 -7.0 -7.6 6.9 6.8 6.8 6.8 6.6 6.2
-5.0 -5.6 7.1 7.1 7.1 6.9 6.6 6.2
-3.0 -3.7 7.5 7.3 7.1 6.9 6.6 6.2
0.0 -0.7 7.6 7.3 7.1 6.9 6.6 6.2
3.0 2.2 7.8 7.6 7.1 6.9 6.6 6.2
5.0 4.1 7.9 7.6 7.1 6.9 6.6 6.2
7.0 6.0 8.0 7.6 7.1 6.9 6.6 6.2
9.0 7.9 8.0 7.6 7.1 6.9 6.6 6.2
11.0 9.8 8.0 7.6 7.1 6.9 6.6 6.2
13.0 11.8 8.0 7.6 7.1 6.9 6.6 6.2
15.0 13.7 8.0 7.6 7.1 6.9 6.6 6.2

Notes:
TC: Total Capacity(kW) 3. In accordance with operation limits of outdoor unit, applicable range of
1. Capacity tables show the representative value of conditions which may occur. capacity tables is different.
2. is shown as reference. When selecting the outdoor units, avoid the 4. Refer to Capacity Correction Factor in the outdoor unit PDB for the actual
outdoor air temperature range shown by . performance data of each indoor unit and outdoor unit combination.

Ceiling Cassette 1-Way _ 13


7. Air Velocity and Temperature Distribution(Reference Data)
ARNU07GTU*2
Cooling Heating
Discharge angle: 50° Discharge angle: 60°

Air velocity [m/s] Air velocity [m/s]


1.5
0.1

0.5
.0
0.1
0.5

5
3.5.
43
1.0
1

1
0.5

0.

5
.5

2.
0.1

22

0.5
0.1
2m 2.0 2m

0.5
5
0.

1.0
1.5
1.5

0.
1
0.5

0.5
0.1
0.5

0.5

1.0
0.1
1.5
1m

5
1m

0.
0.5

1.0
0.5
1

05
1.0
0.1

0.5
0.5
1
0.5
0.5

0.5
0.5 0.1 0.5
0 01 0
5m 4m 3m 2m 1m 0 5m 4m 3m 2m 1m 0

Temperature [°C] Temperature [°C]


32 32 32

4327
30
14

24
26

396
30
16

41 3
30

35

31
28 34
20
30
Indoor Units

33 2m

32
2m

34
28
28

31
36

31

36
32
22

37 8
3
24

34

35
31
32

26

1m 1m

37
24

35 36
28

33
30
26
28

34
36

32
24
28
30

26
26 31 35
28

28 35 36
30 34
0 0
5m 4m 3m 2m 1m 0 5m 4m 3m 2m 1m 0

ARNU09GTU*2
Cooling Heating
Discharge angle: 50° Discharge angle: 60°

Air velocity [m/s] Air velocity [m/s]


2.5

3 0.1 0.1
0.5
1
.5

3.0
5
1.
5 3
0.5

1.5 1.5
2.

0.1
0.1
5
0.
2m 2m
0
2.
1.5
0.5

0.1

2
1

0.5
0.5

0.5

0.5
5
1

0.
1.0
1.0
1

1.0
0.5

1.5 1.0

1m 1m
1.5

0.5
0.5

1.5

0.5
1
0.5

01

0.5
0.1

1
0.5 0.5 1.0
0.5
0 01
0
5m 4m 3m 2m 1m 0 5m 4m 3m 2m 1m 0

Temperature [°C] Temperature [°C]


32 32 31 32 32
38326354
9
22

32
43

30 2284
30 20
35
18

38

36
2m
33

2m
31

28
37
36

36
26 28

33
22
26

32
30

34
3231

37
35
34
33
24

1m 1m
36
28

24
30

28
28

35

34 36
24

31

26
32

35 36
33

28 26 26 32 34
30 30 28 0 0
5m 4m 3m 2m 1m 0 5m 4m 3m 2m 1m 0

Note:
The standard setup height is 2.7m. Shown here is the measurement distribution at the ceiling height of 2.7m

14 _ Ceiling Cassette 1-Way


7. Air Velocity and Temperature Distribution(Reference Data)
ARNU12GTU*2
Cooling Heating
Discharge angle: 50° Discharge angle: 60°

Air velocity [m/s] Air velocity [m/s]


1.0

.5
1.5 0.1 0.1

2 11

.0
420.5
.0 2.

05
0.5
0.5

11.5
1
0.

5
5

0
1.

2.

2.
5
2m 2m
0.5

0.
0.5

05
1

1. 0.

1.0
1
5
0.

1.5

1.50.5
2

1.5
0.1
5
0.1

0.
1.5

0.5

0.1
0.5
0.1
1
0.5

1m 1m
0.5

1.5
1.0

05
1.0
1
0.5 0.5

0.
5
1.0

0.5
0.5 0.5 1.0
0 01 0
5m 4m 3m 2m 1m 0 5m 4m 3m 2m 1m 0

Temperature [°C] Temperature [°C]


32 32 32 32

4064
28

31 32

3
30

41
37
30

26 33

Indoor Units
2m 33
2m
39

34
22
28

37
26

31
24

32
28

3635
30

32

35
31

36
28

24

38
34
36
30

26 1m 1m

37
28

36
34
28
26

33

37

28 26 24 31 35
30 28 26 32 34 3536
0 0
5m 4m 3m 2m 1m 0 5m 4m 3m 2m 1m 0

ARNU18GTT*2
Cooling Heating
Discharge angle: 50° Discharge angle: 60°

Air velocity [m/s] Air velocity [m/s]


5
.5

1
0.53

.5

43.5
01.5
1 4
0.5

5
0.
5
2 2.
2

5 0.5
0.
1 0.5

2m

0.5
2m
5
2.

1.5
2
1

0.5
1

0.5
0.5

0.5

1
1.5

1.5
2

1.5
0.5

0.5

1
1.5

1m 1m
1.5
1

0.5
0.5
1
0.5

0.5
1
0.5
.5

0.5
0 0
5m 4m 3m 2m 1m 0 5m 4m 3m 2m 1m 0

Temperature [°C] Temperature [°C]


32 32 31 32 32
34
8
202

30
35
3364

30
32 32 1
4
30

40

18
39
22

38

28 2m 2m
22
26

30

35 33
31
2628

33
31
24
24

32
28

36
32

37

36

1m 1m
34
36

34
28

24

35
30

28

33
36
33

26
34
2826 24 31
0 0
5m 4m 3m 2m 1m 0 5m 4m 3m 2m 1m 0

Note:
The standard setup height is 2.7m. Shown here is the measurement distribution at the ceiling height of 2.7m

Ceiling Cassette 1-Way _ 15


7. Air Velocity and Temperature Distribution(Reference Data)
ARNU24GTT*2
Cooling Heating
Discharge angle: 50° Discharge angle: 60°

Air velocity [m/s] Air velocity [m/s]


3.5

1
0.5
4.5
0.5

32
5
0.

.5
52

5
2.
1 0.

1 1.
5
1

2
5
2m 0. 2m
0.5

1.55

1
0.

1
1.5
1.5 0.5
0 .5

2
1.5

0.5
0.5
2

1.5
0.5

05
0.5

1.5
1m 1m
0.5

1.5
1

1.5

0.5
1

1
1
1
0.5 1
1

0.5 1 1
0.5
0 0
5m 4m 3m 2m 1m 0 5m 4m 3m 2m 1m 0

Temperature [°C] Temperature [°C]


32 32 32 32
2

36

35
161

30
30 24

31
30

32 4

39
28 32333

40
20
30

31
Indoor Units

28
22

2m
26

2m
28
22

38

36
33
24

36
37
37

34
35
26

33

36
1m 32 1m

36
24
28

31

34

35
28

33
30
24
30

34
31
26

28
28

28
0 0
5m 4m 3m 2m 1m 0 5m 4m 3m 2m 1m 0

Note:
The standard setup height is 2.7m. Shown here is the measurement distribution at the ceiling height of 2.7m

16 _ Ceiling Cassette 1-Way


8. Electric Characteristics
Units Power Supply IFM Input(W)
Model Type Hz Volts Voltage Range MCA MFA kW FLA Cooling Heating
ARNU07GTU*2 TU 1.23 15 0.03 0.18 40 40
ARNU09GTU*2 TU 1.23 15 0.03 0.18 40 40
Max:264
ARNU12GTU*2 TU 50 220-240 1.23 15 0.03 0.18 40 40
Min:198
ARNU18GTT*2 TT 1.38 15 0.03 0.30 70 70
ARNU24GTT*2 TT 1.38 15 0.03 0.30 70 70
ARNU07GTU*2 TU 1.23 15 0.03 0.18 40 40
ARNU09GTU*2 TU 1.23 15 0.03 0.18 40 40
Max:242
ARNU12GTU*2 TU 60 220 1.23 15 0.03 0.18 40 40
Min:198
ARNU18GTT*2 TT 1.38 15 0.03 0.30 70 70
ARNU24GTT*2 TT 1.38 15 0.03 0.30 70 70

Symbols:

Indoor Units
MCA : Minimum Circuit Amperes (A)
MFA : Maximum Fuse Amperes(see note 5)
kW : Fan Motor Rated Output(kW)
FLA : Full Load Amperes(A)
IFM : Indoor Fan Motor

Note :
1. Voltage Range
Units are suitable for use on electrical system where voltage supplied to unit terminals is not below or above the
listed range limits.
2. Maximum allowable voltage unbalance between phase is 2%.
3. MCA/MFA
MCA = 1.25 x FLA
MFA ≤ 4 x FLA
( Next lower standard fuse rating. Minimum 15A)
4. Select wire size based on the larger value on the MCA.
5. Instead of fuse, use Circuit Breaker.

Ceiling Cassette 1-Way _ 17


9. Sound Levels
Overall
Notes:
1. Sound measured at 1.5m away from the center of the unit
2. Operating condition
- Power source : 220-240V 50Hz / 220V 60Hz
- Cooling : Indoor temperature (27°C DB, 19°C WB),
Outdoor temperature (35°C DB, 24°C WB)
- Heating : Indoor temperature (20°C DB, 15°C WB),
1.5m Outdoor temperature (7°C DB, 6°C WB)
3. Reference accoustic pressure 0dB = 20μPa
4. Sound level will vary depending on a range of factors such as
Microphone the construction(acoustic absorption coefficient) of particular
room in which the equipment in installed.
❈ Measuring place : Anechoic chamber

Sound Levels dB(A)


Model
H M L
Indoor Units

ARNU07GTU*2 32 29 25
ARNU09GTU*2 35 34 32
ARNU12GTU*2 38 35 32
ARNU18GTT*2 40 37 35
ARNU24GTT*2 43 40 36

Sound Pressure Level

ARNU07GTU*2 ARNU09GTU*2 ARNU12GTU*2


XP XP XP

WP WP WP
Octave Band Sound Pressure Level (0dB = 20μPa)
Octave Band Sound Pressure Level (0dB = 20μPa)

Octave Band Sound Pressure Level (0dB = 20μPa)

nc MVU ncMVU NC-65


VP VP VP

nc MVP ncMVP NC-60

nc MUU ncMUU NC-55


UP UP UP

nc MUP ncMUP NC-50

nc MTU ncMTU NC-45


TP TP TP

nc MTP ncMTP NC-40

nc MSU ncMSU NC-35


SP SP SP

nc MSP ncMSP NC-30

RP nc MRU RP ncMRU RP NC-25

a’˜‰”… a’˜‰”… ncMRP


Approximate NC-20
nc MRP
h…’‰Ž‡@ h…’‰Ž‡ Hearing
tˆ’…“ˆŒ„ tˆ’…“ˆŒ„ ncMQU Threshold NC-15
nc MQU QP QP
QP
VS QRU RUP UPP QPPP RPPP TPPP XPPP VS QRU RUP UPP QPPP RPPP TPPP XPPP VS QRU RUP UPP QPPP RPPP TPPP XPPP
oƒ”–…@bŽ„@c…Ž”…’@f’…‘•…Žƒ™@HhšI oƒ”–…@bŽ„@c…Ž”…’@f’…‘•…Žƒ™@HhšI oƒ”–…@bŽ„@c…Ž”…’@f’…‘•…Žƒ™@HhšI

18 _ Ceiling Cassette 1-Way


9. Sound Levels
ARNU18GTT*2 ARNU24GTT*2
80 80

70 70

Octave Band Sound Pressure Level (0dB = 20μPa)


Octave Band Sound Pressure Level (0dB = 20μPa)

NC-65 NC-65
60 60
NC-60 NC-60

NC-55 NC-55
50 50

NC-50 NC-50

NC-45 NC-45
40 40

NC-40 NC-40

NC-35 NC-35
30 30

NC-30 NC-30

20 NC-25 20 NC-25

Approximate Approximate
NC-20 NC-20
Hearing Hearing
Threshold Threshold
NC-15 10 NC-15
10

Indoor Units
63 125 250 500 1000 2000 4000 8000
63 125 250 500 1000 2000 4000 8000
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

Ceiling Cassette 1-Way _ 19


10. Installation
• Please read this instruction sheet completely before installing the product.
• When the power cord is damaged, replacement work shall be performed by authorized personnel only.
• Installation work must be performed in accordance with the national wiring standards by authorized personnel only.

Outlet

TEM
Remote
Controlle
P
r
Indoor Units

Inlet
Wired remote
controller

Required Parts Required Tools


• Connecting cable • Level
• Pipes: Gas side • Screw driver
Liquid side • Electric drill
• Hanging Bolt • Hole core drill
(W 3/8 or M10 length 650mm)
• Flaring Tool set
• Insulated drain hose
• Torque Wrenches
• Additional Drain hose
• Hexagonal Wrench
• Gas-leak detector
• Thermometer

10.1 Selection of the best location


• There should not be any heat source or steam near the
unit.
• There should not be any obstacles to the air circulation.
10(13/32)
or more

Ceiling
• A place where air circulation in the room will be good. Ceiling board
300(11-13/16) or less

• A place where drainage can be easily obtained. Ceiling board

• A place where noise prevention is taken into considera-


1000(39-3/8)

3300(129-15/16) or less

tion.
or more

500(19-11/16)
At lesst 1800(70-7/8)

or more 500(19-11/16)
• Do not install the unit near the door way. or more
• Ensure the spaces indicated by arrows from the wall, 17(21/32)
±3(1/8)
ceiling, or other obstacles. Unit:mm(inch)

• The indoor unit must have the maintenance space.


Floor

20 _ Ceiling Cassette 1-Way


10. Installation
10.2 Ceiling opening dimensions and hanging bolt location
• The dimensions of the paper model for installation 1,385
are the same as those of the ceiling opening dimen- 600 50 1,285 50
sions.

40

448
400

306

354
466
1,180
Ceiling

40
250 TT Chassis
Level gauge 1,065
600 50 965 50

40
CAUTION

448
400

306

354
466
860
• This air-conditioner uses a drain pump.

Indoor Units
• Install the unit horizontally using a level gauge.

40
250
• During the installation, care should be taken not to TU Chassis
damage electric wires. (unit: mm)

• Select and mark the position for fixing bolts and pip-
ing hole.
• Decide the position for fixing bolts slightly tilted to
the drain direction after considering the direction of Ceiling board
drain hose.
• Drill the hole for anchor bolt on the wall.

NOTE:
• Avoid the following installation location.
1. Such places as restaurants and kitchen where considerable amount of oil steam and flour is generated.
These may cause heat exchange efficiency reduction, or water drops, drain pump mal-function.
In these cases, take the following actions;
• Make sure that ventilation fan is enough to cover all noxious gases from this place.
• Ensure enough distance from the cooking room to install the air conditioner in such a place where it may
not suck oily steam.

Air conditioner

Take enough
distance
Use the ventilation fan
for smoke-collecting
hood with sufficient
capacity.
Cooking table

2. Avoid installing air conditioner in such places where cooking oil or iron powder is generated.
3. Avoid places where inflammable gas is generated.
4. Avoid place where noxious gas is generated.
5. Avoid places near high frequency generators.

Ceiling Cassette 1-Way _ 21


10. Installation
Ceiling
Hanging bolt Keep the length of the bolt
from the bracket to 40mm

70mm
(W3/8 or M10)
Nut
Flat washer for M10
(W3/8 or M10)
(accessory) Ceiling board Air conditioner body Ceiling board
Spring washer
(M10)

Flat washer for M10


(accessory) Paper model Set screw of
Nut for installation paper model (4 pieces)
(W3/8 or M10)

Adjust the same height Open the ceiling board


along the outer edge of the
paper model

• The following parts are local purchasing. CAUTION


① Hanging bolt - W 3/8 or M10
② Nut - W 3/8 or M10 • Tighten the nut and bolt to prevent the unit
Indoor Units

③ Spring washer - M10 from falling.


④ Plate washer - M10

10.3 Wiring Connection


• Connect the wires to the terminals on the control board individually according to the outdoor unit connection.
• Ensure that the color of the wires of outdoor unit and the terminal No. are the same as those of indoor unit respectively.
[Indoor Unit side] [Outdoor Unit side]

[Type 1]

Terminal block of indoor unit SODU B SODU A IDU B IDU A INT B INT A
1(L) 2(N) 3 4

Indoor power input


[Type 2]
Terminal block of outdoor unit
Terminal block of indoor unit Outdoor unit Indoor unit Central controller
1(L) 2(N) 3 4 SODU SODU IDU IDU INTERNET DRY1 DRY2 GND 12V

Indoor power input


[Type 3]
Terminal block of outdoor unit
Terminal block of indoor unit Central controller Indoor unit Outdoor unit
1(L) 2(N) 3 4 12V GND DRY2 DRY1 CEN CEN IDU IDU SODU SODU

Indoor power input

WARNING
Make sure that the screws of the terminal are not loose.

22 _ Ceiling Cassette 1-Way


10. Installation
10.4 Installation of Decoration Panel (Panel Type)
The decoration panel has its installation Before installing the decoration panel,
direction. always remove the paper template.

1. Open the air outlet vane, and extract side covers.


2. Remove the air inlet panel from the decoration panel.
3. Hook decoration panel to indoor unit, using hooks attached at the backside of both side of decoration
panel.
4. Arrange wires not to get caught between decoration panel and indoor unit.
5. Screw 7 fixing screws. (7,9,12kBtu : 6 screws)
6. Connect the vane motor connector ,display connector and air inlet panel connector.
7. Install the air inlet panel (including the air filter) and side covers.

Air conditioner unit

Indoor Units
Mesh
Control box cover

Side cover
Robot kit

Decorative panel
fixing screws
(hexagon M6 screws)
(tightening about 20mm)

Air inlet panel

Decorative panel
Air outlet vane

CAUTION
Good example Bad example
Install certainly the
decoration panel. Air conditioner Air conditioner
unit Cool air leakage unit
Cool air leakage caus- (no good)
Ceiling Ceiling
es sweating. board board
⇨ Waterdrops fall.
Decorative panel Decorative panel

Fit the insulator (this part) and


be careful for cool air leakage

Ceiling Cassette 1-Way _ 23


10. Installation
10.5 Installation of Decoration Panel(Grille Type)
The decoration panel has its installation Before installing the decoration panel,
direction. always remove the paper template.

1. Open the air outlet vane, and extract side covers.


2. Remove the air inlet grille from the decoration panel.
3. Hook decoration panel to indoor unit, using hooks attached at the backside of both side of decoration
panel.
4. Arrange wires not to get caught between decoration panel and indoor unit.
5. Screw 7 fixing screws. (7,9,12kBtu : 6 screws)
6. Connect the vane motor connector and display connector. (Plasma connector for plasma model)
7. Install the air inlet grille (including the air filter) and side covers.

Air conditioner unit


Indoor Units

Mesh

Control box cover

Side cover

Plasma filter
(applied only to plasma model)
Decorative panel
fixing screws
(hexagon M6 screws)
(tightening about 20mm)

Air inlet grille

Decorative panel

Air inlet grille

CAUTION
Install certainly the Good example Bad example
decoration panel.
Air conditioner Air conditioner
Cool air leakage caus- unit Cool air leakage unit
es sweating. (no good)
Ceiling Ceiling
board board
⇨ Waterdrops fall.
Decorative panel Decorative panel

Fit the insulator (this part) and


be careful for cool air leakage

24 _ Ceiling Cassette 1-Way


10. Installation
10.6 Indoor Unit Drain Piping Upward
Pipe clamp
• Drain piping must have down-slope (1/50 to 1/100): be sure routing
not to provide up-and-down slope to prevent reversal flow. not allowed
• During drain piping connection, be careful not to exert extra Indoor unit
force on the drain port on the indoor unit.
• The outside diameter of the drain connection on the indoor
unit is 32mm.
Maintenance
Piping material: Polyvinyl chloride pipe 25mm drain port
and pipe fittings
• Be sure to install heat insulation on the drain piping.
1/50~1/100
Heat insulation material: Polyethylene foam with
thickness more than 8 mm. Max 700mm

Drain test

Indoor Units
The air conditioner uses a drain pump to drain water.
Use the following procedure to test the drain pump operation:

• Connect the main drain pipe to the exterior


Feed water Flexible drain hose
and leave it provisionally until the test comes
(accessory)
to an end.
Main
• Feed water to the flexible drain hose and
drain pipe
check the piping for leakage.
• Be sure to check the drain pump for normal
Drain
port Glue the joint operating and noise when electrical wiring is
Drain pump
complete.
Drain hose connection
Use the clip (accessory) • When the test is complete, connect the flexi-
ble drain hose to the drain port on the indoor
unit.

Drain pan

CAUTION
Hanger
Max 300mm distance Hanger bracket
The supplied flexible drain hose should not be curved, 1~15m 1/50~1/100 slope
neither screwed. The curved or screwed hose may Metal
Max 700mm

cause a leakage of water. clamp

Flexible drain hose


Insulation

Ceiling Cassette 1-Way _ 25


10. Installation
CAUTION
After the confirmation of the above conditions, prepare the wiring as follows:
1) Never fail to have separate power specially for the air conditioner. As for the method of wiring, follow the circuit
diagram pasted on the inside of control box cover.
2) Provide a circuit breaker switch between power source and the unit.
3) The screw which fasten the wiring in the casing of electrical fittings are liable to come loose from vibrations to
which the unit is subjected during the course of transportation. Check them and make sure that they are all
tightly fastened. (If they are loose, it could give rise to burn-out of the wires.)
4) Confirm the Specification of power source
5) Confirm that electrical capacity is sufficient.
6) Be sure that the starting voltage is maintained at more than 90 percent of the rated voltage marked on the name
plate.
7) Confirm that the cable thickness is as specified in the power sources specification.
(Particularly note the relation between cable length and thickness.)
8) Do not install the leakage breaker in a place which is wet or moist.
Water or moist may cause short circuit.
9) The following troubles would be caused by voltage drop-down.
Indoor Units

• Vibration of a magnetic switch, damage on the contact point there of, fuse breaking, disturbance to the normal function of
a overload protection device.
• Proper starting power is not given to the compressor.

WIRED REMOTE CONTROLLER INSTALLATION


• Since the room temperature sensor is in the remote controller, the remote controller box should be installed in a place away
from direct sunlight, high humidity and direct supply of cold air to maintain proper space temperature.
Install the remote controller about 5ft(1.5m) above the floor in an area with good air circulation at an average temperature.
Do not install the remote controller where it can be affected by:
- Drafts, or dead spots behind doors and in corners.
- Hot or cold air from ducts.
- Radiant heat from sun or appliances.
- Concealed pipes and chimneys.
- Uncontrolled areas such as an outside wall behind the remote controller.
- This remote controller is equipped with a seven segment LED. display. For proper display of the remote controller LED's,
the remote controller should be installed properly as shown in Fig.1.
(The standard height is 1.2~1.5 m from floor level.)

Remote Controller
TEMP
yes

no
TEMP

Remote Controller

no
TEMP
5feet
Remote
Controller

(1.5meters)

no

Fig.1 Typical locations for remote controller

26 _ Ceiling Cassette 1-Way


11. Accessories
Washer for Insulation for
Name Drain hose Clamp metal hanging bracket Plastic band
fitting

Quantity 1 EA 2 EA 8 EA 4 EA 1 SET

Shape for gas pipe

for liquid pipe

Name Paper pattern for installation Installation and Owner's manual

Indoor Units
Quantity 1EA 1EA

Shape

CAUTION
• Use only those accessories (Standard or optional) which have designated specifications.

Ceiling Cassette 1-Way _ 27


Indoor unit
Ceiling Cassette 2-Way
1. List of functions

2. Specifications

3. Dimensions

4. Piping Diagrams

5. Wiring Diagrams

6. Capacity Tables

7. Air Velocity and Temperature Distribution

8. Electric Characteristics

9. Sound Levels

10. Installation

11. Accessories
1. List of functions
Category Function ARNU18GTL*2, ARNU24GTL*2

Air supply outlet 2


Airflow direction control(left & right) -
Airflow direction control(up & down) Auto
Auto swing(left & right) -
Auto swing(up & down) O
Air flow
Airflow steps(fan/cool/heat) 4/5/4
Chaos swing X
Chaos wind(auto wind) O
Jet cool(Power wind) O
Swirl wind -
Deodorizing filter X
Air purifying Plasma air purifier Option
Prefilter(washable / anti-fungus) O
Drain pump O
E.S.P. control X
Installation
Electric heater(operation) X

Indoor Units
High ceiling operation O
Hot start O
Reliability Self diagnosis O
Soft dry operation O
Auto changeover O(Heat recovery)
Auto cleaning X
Auto operation(artificial intelligence) O(Heat pump or Cooling only)
Auto restart operation O
Child lock O
Convenience Forced operation O
Group control O
Sleep mode O
Timer(on/off) O
Timer(weekly) O
Two thermistor control O
Wide wired remote controller PQRCVSL0/PQRCVSL0QW
Deluxe wired remote controller X
Individual
Simple wired remote controller PQRCVCL0Q(W)
control
Wired remote controller(for hotel use) PQRCHCA0Q(W)
Wireless LCD remote control PQWRH(C)Q0FDB
Zone control -
CTIE -
Special Electro thermostat -
function kit Remote temperature sensor PQRSTA0
Group control wire PZCWRCG3
Dry contact PQDSA(1)/PQDSB(1)/PQDSBC/PQDSBNGCM1/PQDSBCGCD0

O : Applied X : Not applied – : No relation


Option : Model name & price are different according to options, and assembled in factory with main unit.
Accessory : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate
package.

Ceiling Cassette 2-way _ 1


2. Specifications
* Model Name
A:Basic, C:Plasma
Type 2Way Ceiling Cassette
Model Unit ARNU18GTL*2
kW 5.6
Cooling Capacity kcal/h 4,800
Btu/h 19,100
kW 6.3
Heating Capacity kcal/h 5,400
Btu/h 21,500
Casing Galvanized Steel Plate
mm 830 x 225 x 550
Body
inch 32-11/16 x 8-27/32 x 21-21/32
Dimensions (WxHxD)
mm 1,050 x 28 x 640
Front Panel
inch 41-11/32 x 1-3/32 x 25-3/16
Coil Rows x Columns x FPI 2 x 11 x 20
Face Area m2 0.13
Indoor Units

Type Cross Flow Fan


Motor Output x Number W 20 x 2
Running Current A 0.18 x 2
Fan Air Flow Rate(H / M / L) CMM 13 / 12 / 10
cfm 459 / 424 / 353
Drive Direct
Motor type BLDC
Temperature Control Microprocessor, Thermostat for cooling and heating
Sound Absorbing Thermal Insulation Material Foamed polystrene
Safety Device Fuse
Liquid Side mm(inch) Ø6.35(1/4)
Pipe Connections Gas Side mm(inch) Ø12.7(1/2)
Drain Pipe(Internal Dia.) mm(inch) 25(1)
Net Weight Body kg(lbs) 22(48.5)
Noise Level(Sound Press, 1.5m, H / M / L) dB(A) 40 / 36 / 32
Power Supply Ø, V, Hz 1, 220-240, 50
1, 220, 60
Refrigerant Control EEV
Power cable CV1.5 x 3C
Transmission cable CVV-SB 1.0~1.5 x 2C
Panel Color Morning fog
Panel Name(Accessory) PT-HL*
Notes:-
1. Capacities are based on the following conditions: Conversion Formula
Cooling • Indoor temp. 27°C[80.6°F]DB/ 19°C[66.2°F]WB kcal/h= kW x 860
• Outdoor temp. 35°C[95°F]DB/ 24°C[75.2°F]WB Btu/h = kW x 3412
• Interconnecting Piping Length 7.5m cfm = m3/min x 35.3
• Level Difference of Zero l/s = CMM x 1000/60
Heating • Indoor temp. 20°C[68°F]DB/ 15°C[59°F]WB
• Outdoor temp. 7°C[44.6°F]DB/ 6°C[42.8°F]WB
• Interconnecting Piping Length 7.5m
• Level Difference of Zero
2. Capacities are Net Capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve
6. Anechoic chamber conversion value is measured at 1.5 m downward from unit centre.
The values depends on the ambient conditions and values are normally higher in actual operation.

2 _ Ceiling Cassette 2-way


2. Specifications
* Model Name
A:Basic, C:Plasma
Type 2Way Ceiling Cassette
Model Unit ARNU24GTL*2
kW 7.1
Cooling Capacity kcal/h 6,100
Btu/h 24,200
kW 8.0
Heating Capacity kcal/h 6,900
Btu/h 27,300
Casing Galvanized Steel Plate
mm 830 x 225 x 550
Body
inch 32-11/16 x 8-27/32 x 21-21/32
Dimensions (WxHxD)
mm 1,050 x 28 x 640
Front Panel
inch 41-11/32 x 1-3/32 x 25-3/16
Coil Rows x Columns x FPI 2 x 11 x 20
Face Area m2 0.13

Indoor Units
Type Cross Flow Fan
Motor Output x Number W 20 x 2
Running Current A 0.18 x 2
Fan Air Flow Rate(H / M / L) CMM 17 / 15 / 13
cfm 601 / 530 / 459
Drive Direct
Motor type BLDC
Temperature Control Microprocessor, Thermostat for cooling and heating
Sound Absorbing Thermal Insulation Material Foamed polystrene
Safety Device Fuse
Liquid Side mm(inch) Ø9.52(3/8)
Pipe Connections Gas Side mm(inch) Ø15.88(5/8)
Drain Pipe(Internal Dia.) mm(inch) 25(1)
Net Weight Body kg(lbs) 22(48.5)
Noise Level(Sound Press, 1.5m, H / M / L) dB(A) 42 / 38 / 34
Power Supply Ø, V, Hz 1, 220-240, 50
1, 220, 60
Refrigerant Control EEV
Power cable CV1.5 x 3C
Transmission cable CVV-SB 1.0~1.5 x 2C
Panel Color Morning fog
Panel Name(Accessory) PT-HL*
Notes:-
1. Capacities are based on the following conditions: Conversion Formula
Cooling • Indoor temp. 27°C[80.6°F]DB/ 19°C[66.2°F]WB kcal/h= kW x 860
• Outdoor temp. 35°C[95°F]DB/ 24°C[75.2°F]WB Btu/h = kW x 3412
• Interconnecting Piping Length 7.5m cfm = m3/min x 35.3
• Level Difference of Zero l/s = CMM x 1000/60
Heating • Indoor temp. 20°C[68°F]DB/ 15°C[59°F]WB
• Outdoor temp. 7°C[44.6°F]DB/ 6°C[42.8°F]WB
• Interconnecting Piping Length 7.5m
• Level Difference of Zero
2. Capacities are Net Capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve
6. Anechoic chamber conversion value is measured at 1.5 m downward from unit centre.
The values depends on the ambient conditions and values are normally higher in actual operation.

Ceiling Cassette 2-way _ 3


Indoor Units

Ceiling Cassette 2-way

ARNU18GTL*2
ARNU24GTL*2

931.2
35.6 830 2 92

34
3. Dimensions

(unit : mm)
Number Name Descripition

205.5
206.5

4 _ Ceiling Cassette 2-way


1 Liquid pipe connection Unit size(18k):ø6.35

482
550
6.5 Unit size(24k):ø9.52

69.2

69.2
2 Gas pipe connection Unit size(18k):ø12.7
Unit size(24k):ø15.88

162.4
3 Air suction grill
893 1 177.1 4 Air discharge grill
225

Note

144.2
1. Unit should be installed in compliance with the installation manual
in the product box.

4-R15 2. Unit shall be grounded in accordance with the local regulations or


applicable national codes.

640
3 921(Air Outlet Hole)
1,050
28

76, Seongsan-dong, Changwon City, Gyeongnam,


641-713, Korea CHASSIS CODE: TL
4. Piping Diagrams

:Cooling
Heat Exchanger EEV :Heating
Filter
Th3 Th2
C.F.F.
Filter

Th1 lndoor unit

Indoor Units
Refrigerant pipe connection port diameter

[Unit: mm(inch)]

Model Gas Liquid

ARNU18GTL*2 Ø12.7(1/2) Ø6.35(1/4)

ARNU24GTL*2 Ø15.88(5/8) Ø9.52(3/8)

LOC. Description
Th1 Room thermistor
Th2 Pipe in thermistor
Th3 Pipe out thermistor

Ceiling Cassette 2-way _ 5


5. Wiring Diagrams
TL Chassis
Indoor Units

CONNECTOR NUMBER SPEC DESCRIPTION


CN-POWER AC Power supply AC Power line input for indoor controller
CN-MOTOR1 Fan motor output Motor output of BLDC
CN-MOTOR2 Fan motor output Motor output of BLDC
CN-D/PUMP Drain pump output AC output for drain pump
CN-485 Communication Connection between indoor and outdoor
CN-DISP Display Display of indoor status
CN-EEV EEV Output EEV Control output
CN-VANE2 Step motor Step motor output
CN-FLOAT Float switch input Float switch sensing
CN-PIPE/IN Suction pipe sensor Pipe in thermistor
CN-PIPE/OUT Discharge pipe sensor Pipe out thermistor
CN-ROOM Room sensor Room air thermistor
CN-REMO Remote controller Remote control line
Dip Switch Setting Off On Remarks
SW3 GROUP Master Slave Group Control setting using Wired Remote Controller
Old Dry Contact Mode Setting
1. Variable : Auto/Manual Mode can be chosen by Wide wired
SW4 DRY CONTACT Variable Auto remote controller or Wireless remote controller
(When shipped from Factory → Manual Mode)
2. Auto : For Dry Contact, it is always Auto mode.
1. Duct model
-. OFF : Default(not operate continuosly )
-. ON : Fan operate continuosly
SW5 EXTRA 1 Off On 2. Cassette Model : No Function
3. Ceiling Suspended Model
-. OFF : Ceiling(default)
-. ON : Floor

CAUTION
For Multi V Model, Dip Switch 1,2,6,7,8 must be set OFF
That dip switch is used for the other model.

6 _ Ceiling Cassette 2-way


6. Capacity Tables
6.1 Cooling Capacity Cooling capacity

Indoor air temp. (DB/WB, °C)


Capacity Outdoor 20 23 26 27 28 30 32
Index air temp. 14 16 18 19 20 22 24
(DB, °C) TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 6.0 4.0 6.7 4.2 7.4 4.2

12 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 6.0 4.0 6.7 4.2 7.3 4.1

14 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 6.0 4.0 6.7 4.2 7.2 4.1

16 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 6.0 4.0 6.7 4.2 7.1 4.0

18 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 6.0 4.0 6.7 4.2 7.0 4.0

Indoor Units
20 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 6.0 4.0 6.7 4.2 6.9 3.9

21 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 6.0 4.0 6.7 4.2 6.8 3.9

23 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 6.0 4.0 6.7 4.2 6.7 3.8
5.6
25 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 6.0 4.0 6.6 4.2 6.6 3.8

27 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 6.0 4.0 6.4 4.1 6.6 3.7

29 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 6.0 4.0 6.4 4.0 6.5 3.7

31 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 6.0 4.0 6.3 3.9 6.4 3.6

33 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 6.0 4.0 6.2 3.9 6.3 3.6

35 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 6.0 4.0 6.0 3.8 6.2 3.5

37 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 5.8 3.9 5.9 3.7 6.1 3.5

39 3.8 3.2 4.5 3.6 5.2 3.9 5.6 3.9 5.7 3.9 5.8 3.7 6.0 3.4

Ceiling Cassette 2-way _ 7


6. Capacity Tables
Cooling capacity

Indoor air temp. (DB/WB, °C)


Capacity Outdoor 20 23 26 27 28 30 32
Index air temp. 14 16 18 19 20 22 24
(DB, °C) TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.6 5.1 8.5 5.3 9.3 5.3

12 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.6 5.1 8.5 5.3 9.2 5.2

14 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.6 5.1 8.5 5.3 9.1 5.2

16 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.6 5.1 8.5 5.3 9.0 5.1

18 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.6 5.1 8.5 5.3 8.8 5.0
Indoor Units

20 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.6 5.1 8.5 5.3 8.7 5.0

21 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.6 5.1 8.5 5.3 8.7 4.9

23 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.6 5.1 8.5 5.3 8.5 4.9
7.1
25 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.6 5.1 8.4 5.3 8.4 4.8

27 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.6 5.1 8.2 5.1 8.3 4.7

29 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.6 5.1 8.1 5.1 8.2 4.7

31 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.6 5.1 8.0 5.0 8.1 4.6

33 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.6 5.1 7.8 4.9 7.9 4.5

35 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.6 5.1 7.7 4.8 7.8 4.4

37 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.4 5.0 7.5 4.7 7.7 4.4

39 4.8 4.1 5.7 4.5 6.6 4.9 7.1 5.0 7.2 4.9 7.4 4.6 7.6 4.3

Notes:
TC: Total Capacity(kW), SHC: Sensible Heat Capacity(kW) 2. Refer to Capacity Correction Factor in the outdoor unit PDB for
1. Capacity tables show the representative value of conditions the actual performance data of each indoor unit and outdoor unit
which may occur. combination.

8 _ Ceiling Cassette 2-way


6. Capacity Tables
6.2 Heating Capacity Heating capacity

Outdoor air Indoor air temp. (DB, °C)


Capacity temp. 16 18 20 21 22 24
Index TC TC TC TC TC TC
DB(°C) WB(°C)
kW kW kW kW kW kW
-24.8 -25.0 3.6 3.6 3.6 3.6 3.6 3.6
-21.8 -22.0 4.4 4.4 4.4 4.4 4.4 4.4
-19.8 -20.0 4.6 4.6 4.6 4.6 4.6 4.6
-18.8 -19.0 4.8 4.7 4.7 4.7 4.7 4.7
-16.7 -17.0 5.0 5.0 5.0 4.9 4.9 4.9
-14.7 -15.0 5.2 5.2 5.2 5.2 5.2 5.2

Indoor Units
-12.6 -13.0 5.5 5.4 5.4 5.4 5.4 5.4
-10.5 -11.0 5.7 5.7 5.7 5.7 5.7 5.5
-9.5 -10.0 5.8 5.8 5.8 5.8 5.8 5.5
-8.5 -9.1 5.9 5.9 5.9 5.9 5.9 5.5
-7.0 -7.6 6.1 6.1 6.1 6.0 5.9 5.5
5.6
-5.0 -5.6 6.3 6.3 6.3 6.1 5.9 5.5
-3.0 -3.7 6.6 6.5 6.3 6.1 5.9 5.5
0.0 -0.7 6.7 6.5 6.3 6.1 5.9 5.5
3.0 2.2 6.9 6.7 6.3 6.1 5.9 5.5
5.0 4.1 7.0 6.7 6.3 6.1 5.9 5.5
7.0 6.0 7.1 6.7 6.3 6.1 5.9 5.5
9.0 7.9 7.1 6.7 6.3 6.1 5.9 5.5
11.0 9.8 7.1 6.7 6.3 6.1 5.9 5.5
13.0 11.8 7.1 6.7 6.3 6.1 5.9 5.5
15.0 13.7 7.1 6.7 6.3 6.1 5.9 5.5

Ceiling Cassette 2-way _ 9


6. Capacity Tables
Heating capacity

Outdoor air Indoor air temp. (DB, °C)


Capacity temp. 16 18 20 21 22 24
Index TC TC TC TC TC TC
DB(°C) WB(°C)
kW kW kW kW kW kW
-24.8 -25.0 4.6 4.6 4.6 4.6 4.6 4.6
-21.8 -22.0 5.6 5.6 5.6 5.6 5.6 5.5
-19.8 -20.0 5.9 5.9 5.9 5.9 5.9 5.8
-18.8 -19.0 6.0 6.0 6.0 6.0 6.0 6.0
-16.7 -17.0 6.3 6.3 6.3 6.3 6.3 6.3
-14.7 -15.0 6.6 6.6 6.6 6.6 6.6 6.6
-12.6 -13.0 6.9 6.9 6.9 6.9 6.9 6.9
Indoor Units

-10.5 -11.0 7.2 7.2 7.2 7.2 7.2 7.0


-9.5 -10.0 7.4 7.4 7.3 7.3 7.3 7.0
-8.5 -9.1 7.5 7.5 7.5 7.5 7.5 7.0
7.1 -7.0 -7.6 7.7 7.7 7.7 7.7 7.5 7.0
-5.0 -5.6 8.0 8.0 8.0 7.7 7.5 7.0
-3.0 -3.7 8.4 8.2 8.0 7.7 7.5 7.0
0.0 -0.7 8.6 8.3 8.0 7.7 7.5 7.0
3.0 2.2 8.8 8.5 8.0 7.7 7.5 7.0
5.0 4.1 8.9 8.5 8.0 7.7 7.5 7.0
7.0 6.0 9.0 8.5 8.0 7.7 7.5 7.0
9.0 7.9 9.0 8.5 8.0 7.7 7.5 7.0
11.0 9.8 9.0 8.5 8.0 7.7 7.5 7.0
13.0 11.8 9.0 8.5 8.0 7.7 7.5 7.0
15.0 13.7 9.0 8.5 8.0 7.7 7.5 7.0

Notes:
TC: Total Capacity(kW) 3. In accordance with operation limits of outdoor unit, applicable range of
1. Capacity tables show the representative value of conditions which may occur. capacity tables is different.
2. is shown as reference. When selecting the outdoor units, avoid the 4. Refer to Capacity Correction Factor in the outdoor unit PDB for the actual
outdoor air temperature range shown by . performance data of each indoor unit and outdoor unit combination.

10 _ Ceiling Cassette 2-way


7. Air Velocity and Temperature Distribution(Reference Data)
ARNU24GTL*2
Cooling Heating
Discharge angle: 40° Discharge angle: 60°

Air velocity [m/s] Air velocity [m/s]

2.7m 2.7m
3.0 3.0
2.5 2.5 2.5 2.5
2.0 2.0 2m 2m
1.5 1.5 2.0 2.0

1.0 1.0 1.5 1.5


1m 1m
0.5 0.5 1.0 1.0
0.5 0.5
0m 0m
4m 3m 2m 1m 0m 1m 2m 3m 4m 4m 3m 2m 1m 0m 1m 2m 3m 4m

Temperature [°C] Temperature [°C]

Indoor Units
2.7m 2.7m
20 20 32 32
21 21
22 22 31 31
2m 2m
23 23 30 30

24 24 1m 29 27 29 1m
28 28
28 28
26 27 27 26
0m 0m
4m 3m 2m 1m 0m 1m 2m 3m 4m 4m 3m 2m 1m 0m 1m 2m 3m 4m

Ceiling Cassette 2-way _ 11


8. Electric Characteristics
Units Power Supply IFM Input(W)
Model Type Hz Volts Voltage Range MCA MFA kW FLA Cooling Heating
ARNU18GTL*2 TL Max:264 0.52 15 0.04 0.41 70 70
50 220-240
ARNU24GTL*2 TL Min:198 0.52 15 0.04 0.41 70 70
ARNU18GTL*2 TL Max:242 0.52 15 0.04 0.41 70 70
60 220
ARNU24GTL*2 TL Min:198 0.52 15 0.04 0.41 70 70

Symbols:
MCA : Minimum Circuit Amperes (A)
MFA : Maximum Fuse Amperes(see note 5)
kW : Fan Motor Rated Output(kW)
FLA : Full Load Amperes(A)
IFM : Indoor Fan Motor

Note :
Indoor Units

1. Voltage Range
Units are suitable for use on electrical system where voltage supplied to unit terminals is not below or above the
listed range limits.
2. Maximum allowable voltage unbalance between phase is 2%.
3. MCA/MFA
MCA = 1.25 x FLA
MFA ≤ 4 x FLA
( Next lower standard fuse rating. Minimum 15A)
4. Select wire size based on the larger value on the MCA.
5. Instead of fuse, use Circuit Breaker.

12 _ Ceiling Cassette 2-way


9. Sound Levels
Overall
Notes:
1. Sound measured at 1.5m away from the center of the unit
2. Operating condition
- Power source : 220-240V 50Hz / 220V 60Hz
- Cooling : Indoor temperature (27°C DB, 19°C WB),
1.5m Outdoor temperature (35°C DB, 24°C WB)
- Heating : Indoor temperature (20°C DB, 15°C WB),
Outdoor temperature (7°C DB, 6°C WB)
Microphone 3. Reference accoustic pressure 0dB = 20μPa
4. Sound level will vary depending on a range of factors such as
❈ Measuring place : Anechoic chamber the construction(acoustic absorption coefficient) of particular
room in which the equipment in installed.

Sound Levels dB(A)


Model
H M L
ARNU18GTL*2 40 36 32
ARNU24GTL*2 42 38 34

Indoor Units
Sound Pressure Level
ARNU18GTL*2 ARNU24GTL*2
80 80

70 70
Octave Band Sound Pressure Level (0dB = 20μPa)

Octave Band Sound Pressure Level (0dB = 20μPa)

NC-65 NC-65
60 60

NC-60 NC-60

NC-55 NC-55
50 50

NC-50 NC-50

NC-45 NC-45
40 40

NC-40 NC-40

NC-35 NC-35
30 30

NC-30 NC-30

20 NC-25 20 NC-25

Approximate Approximate
NC-20 NC-20
Hearing Hearing
Threshold Threshold NC-15
10 NC-15 10
63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000

Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

Ceiling Cassette 2-way _ 13


10. Installation
• Please read the instruction sheets completely before installing the product.
• When the power cord is damaged, replacement work shall be performed by authorized personnel only.
• Installation work must be performed in accordance with the national wiring standards by authorized personnel only.

Anti-bacteria filter
Indoor Units

TEMP

Remote Controller

Air Intake
Air Outlet

Required Parts Required Tools


• Connecting cable • Level
• Pipes: Gas side • Screw driver
Liquid side • Electric drill
• Hanging Bolt • Hole core drill
(W 3/8 or M10 length 650mm)
• Flaring Tool set
• Insulated drain hose
• Torque Wrenches
• Additional Drain hose
• Hexagonal Wrench
• Gas-leak detector
• Thermometer

10.1 Selection of the best location


• There should not be any heat source or steam near the
unit.
• There should not be any obstacles to the air circula-
20 or more

Ceiling Ceiling Board


tion. Ceiling Board
• A place where air circulation in the room will be good.
30 or less

• A place where drainage can be easily obtained.


or more

50 or 50 or
• A place where noise prevention is taken into consider- more more
300 or less
Above 200
100

ation.
• Do not install the unit near the door way.
Unit:cm
• Ensure the spaces indicated by arrows from the wall,
ceiling, or other obstacles.
Floor
• The indoor unit must have sufficient maintenance
space.

14 _ Ceiling Cassette 2-way


10. Installation
10.2 Ceiling opening dimensions and hanging bolt location
• The dimensions of the paper pattern for installation
are the same as those of the ceiling opening
dimensions.

Ceiling board

Ceiling

Level gauge • Select and mark the position for fixing bolts and
piping hole.
• Decide the position for fixing bolts slightly tilted
to the drain direction after considering the direc-
CAUTION
tion of drain hose.
• This air-conditioner uses a drain pump. • Drill the hole for anchor bolt on the wall.

Indoor Units
• Install the unit horizontally using a level gauge.
• During the installation, care should be taken not to
damage electric wires.

NOTE:
• Avoid the following installation location.
1. Such places as restaurants and kitchen where considerable amount of oil steam and flour is generated.
These may cause heat exchange efficiency reduction, or water drops, drain pump mal-function.
In these cases, take the following actions;
• Make sure that ventilation fan is enough to cover all noxious gases from this place.
• Ensure enough distance from the cooking room to install the air conditioner in such a place where it may
not suck oily steam.

Air conditioner

Take enough
distance
Use the ventilation fan
for smoke-collecting
hood with sufficient
capacity.
Cooking table

2. Avoid installng air conditioner in such places where cooking oil or iron powder is generated.
3. Avoid places where inflammable gas is generated.
4. Avoid place where noxious gas is generated.
5. Avoid places near high frequency generators.

Ceiling Cassette 2-way _ 15


10. Installation
Ceiling
Hanging bolt Keep the length of the bolt
from the bracket to 40mm

90mm
(W3/8 or M10)
Nut
Flat washer for M10
(W3/8 or M10) False
(accessory) Air Conditioner body False ceiling board
ceiling board

Flat washer for M10


(accessory) Paper pattern Set screw of
Nut for installation paper pattern (4 pieces)
(W3/8 or M10)

Adjust the same height Open the ceiling board


along the outer edge of the
paper pattern

• The following parts are locally purchased. CAUTION


① Hanging Bolt - W 3/8 or M10
② Nut - W 3/8 or M10 • Tighten the nut and bolt to prevent the unit
Indoor Units

③ Spring Washer - M10 from falling.


④ Plate Washer - M10

10.3 Wiring Connection


Connect the wires to the terminals on the control board individually according to the outdoor unit connection.
• Ensure that the color of the wires of outdoor unit and the terminal No. are the same as those of indoor unit respectively.

[Indoor Unit side] [Outdoor Unit side]

[Type 1]

Terminal Block Indoor SODU B SODU A IDU B IDU A INT B INT A


1(L) 2(N) 3 4

INDOOR POWER INPUT


[Type 2]
Terminal Block Indoor SODU IDU INTERNET DRY1 DRY2 GND 12V
1(L) 2(N) 3 4 B A - - B A - - - -

INDOOR POWER INPUT


[Type 3]
Terminal block of outdoor unit
Terminal Block Indoor Central controller Indoor unit Outdoor unit
1(L) 2(N) 3 4 12V GND DRY2 DRY1 CEN CEN IDU IDU SODU SODU

INDOOR POWER INPUT

WARNING
Make sure that the screws of the terminal are not loose.

16 _ Ceiling Cassette 2-way


10. Installation
10.4 Installation of Decoration Panel
The decoration panel has its installation Before installing the decoration panel,
direction. always remove the paper template.

1. Temporarily fix two decoration panel fixing screws (hexagon M5 screw) on the unit body. (Tighten by amount 10mm in
length.)
The fixing screws (hexagon M5 screw) are included in the indoor unit box.
2. Remove the air inlet grille from the decoration panel. (Remove the hook for the air inlet grille cord.)
3. Hook the decoration panel key hole ( ) on the screws fixed in step above, and slide the panel so that the screws
reach the key hole edge.
4. Retighten completely two temporarily fixed screws and other two screws. (Total 4 screws)
5. Connect the louver motor connector and display connector.
6. After tightening these screws, install the air inlet grille
(including the air filter).
Air conditioner unit

Indoor Units
Decorative panel
fixing screws
(hexagon M6 screws)
Temporary fitting
Piping side at 2 poles
(Tightening about 10mm)
Control box cover
Cover
Plasma filter

Louver motor Key holes

Decorative panel Decorative panel


fixing screws
Push (Hexagon M6 screw)

Ratch
pull

Inlet Grille
CAUTION
Install the decoration panel Correct method Wrong method
otherwise cool air leakage
causes condensation. Air conditioner Air conditioner
unit unit
⇨ Water drops fall. Cool air leakage
(no good)
Ceiling Ceiling
board board

Decoration panel Decoration panel

Fit the insulator (this part) and


be careful for cool air leakage

Ceiling Cassette 2-way _ 17


10. Installation
10.5 Indoor Unit Drain Piping Pipe clamp
Upward
• Drain piping must have down-slope (1/50 to 1/100): Make sure routing
not allowed
not to provide up-and-down slope to prevent reversal flow.
Indoor unit
• During drain piping connection, be careful not to exert extra
force on the drain port on the indoor unit.
• The outside diameter of the drain connection on the indoor
unit is 32mm. Maintenance
drain port
Piping material: Polyvinyl chloride pipe inner
diameter Ø 25mm and pipe fittings
• Make sure to install heat insulation on the drain piping. 1/50~1/100

MAX 700mm
Heat insulation material: Polyethylene foam with
thickness more than 8 mm.

Drain test
Indoor Units

The air conditioner uses a drain pump to drain water.


Use the following procedure to test the drain pump operation:

Feed water Flexible drain hose • Connect the main drain pipe to the exterior and leave it
(accessory) provisionally until the test comes to an end.
Main • Feed water to the flexible drain hose and check the pip-
drain pipe ing for leakage.
• Make sure to check the drain pump for normal operating
Drain
port Glue the joint
and noise when electrical wiring is complete.
Drain Pump
• When the test is complete, connect the flexible drain
Drain hose connection
Use the clip (accessory) hose to the drain port on the indoor unit.

Drain pan

CAUTION Hanger
Max 300mm distance Hanger Bracket
The supplied flexible drain hose should not be strained. 1~15m 1/50~1/100 slope
A strained hose may cause leakage of water. Metal
Max 700mm

clamp

Flexible drain hose


Insulation

18 _ Ceiling Cassette 2-way


10. Installation
CAUTION

After the confirmation of the above conditions, prepare the wiring as follows:
1) Never fail to have separate power specially for the air conditioner. As for the method of wiring, follow the circuit diagram
pasted on the inside of control box cover.
2) Provide a circuit breaker switch between power source and the unit.
3) The screw which fasten the wiring in the casing of electrical fittings are liable to come loose from vibrations to which the
unit is subjected during the course of transportation. Check them and make sure that they are all tightly fastened. (If they are
loose, it could give rise to burn-out of the wires.)
4) Confirm the specification of power source
5) Confirm that electrical capacity is sufficient.
6) Be sure that the starting voltage is maintained at more than 90 percent of the rated voltage marked on the name plate.
7) Confirm that the cable thickness is as specified in the power sources specification.
(Particularly note the relation between cable length and thickness.)
8) Do not install the leakage breaker in a place which is wet or moist.
Water or moist may cause short circuit.
9) The following troubles would be caused by voltage drop-down.

Indoor Units
• Vibration of a magnetic switch, damage on the contact point there of, fuse breaking, disturbance to the normal function of a over-
load protection device.
• Proper starting power is not given to the compressor.
HAND OVER
Teach the customer the operation and maintenance procedures, using the operation manual.
(air filter cleaning, temperature control, etc.)

WIRED REMOTE CONTROLLER INSTALLATION


• Since the room temperature sensor is in the remote controller, the remote controller box should be installed in a place away
from direct sunlight, high humidity and direct supply of cold air to maintain proper space temperature.
Install the remote controller about 5ft(1.5m) above the floor in an area with good air circulation at an average temperature.
Do not install the remote controller where it can be affected by:
- Drafts, or dead spots behind doors and in corners.
- Hot or cold air from ducts.
- Radiant heat from sun or appliances.
- Concealed pipes and chimneys.
- Uncontrolled areas such as an outside wall behind the remote controller.
- This remote controller is equipped with a seven segment LED. display. For proper display of the remote controller
LED's, the remote controller should be installed properly as shown in Fig.1.
(The standard height is 1.2~1.5 m from floor level.)

Remote Controller
TEMP
yes

no
TEMP

Remote Controller

no
TEMP
5feet
Remote
Controller

(1.5meters)

no

Fig.1 Typical locations for remote controller

Ceiling Cassette 2-way _ 19


11. Accessories
Standard Accessories
Insulation for Washer for Clamp (Other)
Name Clamp metal Drain hose hanging bracket Bolt
fitting (Tie Wrap)

Quantity 2 EA 1 EA 1 set 8 EA 4 EA 4 EA
• Paper pattern for
installation
• Owner's manual
• Installation manual
Shape for gas pipe

for liquid pipe

• Screws for fixing panels are attached to decoration panel.


Indoor Units

CAUTION
• Use only those accessories (Standard or optional) which have designated specifications.

20 _ Ceiling Cassette 2-way


Indoor unit

Ceiling Cassette 4-way


1. List of functions

2. Specifications

3. Dimensions

4. Piping Diagrams

5. Wiring Diagrams

6. Capacity Tables

7. Air Velocity and Temperature Distribution

8. Electric Characteristics

9. Sound Levels

10. Installation

11. Accessories
1. List of functions
ARNU05GTR*2, ARNU07GTR*2, ARNU09GTR*2, ARNU12GTR*2
Category Function ARNU15GTQ*2, ARNU18GTQ*2, ARNU24GTP*2, ARNU28GTP*2
ARNU36GTN*2, ARNU42GTM*2, ARNU48GTM*2
Air supply outlet 4
Airflow direction control(left & right) -
Airflow direction control(up & down) Auto
Auto swing(left & right) -
Auto swing(up & down) O
Air flow
Airflow steps(fan/cool/heat) 4/5/4
Chaos swing X
Chaos wind(auto wind) O
Jet cool(Power wind) O
Swirl wind O
Deodorizing filter X
Air purifying Plasma air purifier Option
Prefilter(washable / anti-fungus) O
Drain pump O
E.S.P. control X
Installation
Electric heater(operation) X

Indoor Units
High ceiling operation O
Hot start O
Reliability Self diagnosis O
Soft dry operation O
Auto changeover O(Heat recovery)
Auto cleaning X
Auto operation(artificial intelligence) O(Heat pump or Cooling only)
Auto restart operation O
Child lock O
Convenience Forced operation O
Group control O
Sleep mode O
Timer(on/off) O
Timer(weekly) O
Two thermistor control O
Elevation Grill PTEGM0 (TM,TN,TP only)
Wide wired remote controller PQRCVSL0/PQRCVSL0QW
Deluxe wired remote controller X
Individual Simple wired remote controller PQRCVCL0Q(W)
control Wired remote controller(for hotel use) PQRCHCA0Q(W)
Wireless LCD remote control PQWRH(C)Q0FDB
Zone control -
CTIE -
Special Electro thermostat -
function kit Remote temperature sensor PQRSTA0
Group control wire PZCWRCG3
Dry contact PQDSA(1)/PQDSB(1)/PQDSBC/PQDSBNGCM1/PQDSBCGCD0

O : Applied X : Not applied – : No relation


Option : Model name & price are different according to options, and assembled in factory with main unit.
Accessory : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate
package.
* Plasma kit and Elevation Grille are not applicable at the same time

Ceiling Cassette 4-way _ 1


2. Specifications
* Model Name
A:Basic, C:Plasma
Type 4 Way Ceiling Cassette
Model Unit ARNU05GTR*2 ARNU07GTR*2 ARNU09GTR*2
kW 1.6 2.2 2.8
Cooling Capacity kcal/h 1,400 1,900 2,400
Btu/h 5,500 7,500 9,600
kW 1.8 2.5 3.2
Heating Capacity kcal/h 1,500 2,200 2,800
Btu/h 6,100 8,500 10,900
Casing Galvanized Steel Plate Galvanized Steel Plate Galvanized Steel Plate
mm 570 x 214 x 570 570 x 214 x 570 570 x 214 x 570
Body
inch 22-7/16 x 8-7/16 x 22-7/16 22-7/16 x 8-7/16 x 22-7/16 22-7/16 x 8-7/16 x 22-7/16
Dimensions(WxHxD)
mm 700 x 22 x 700 700 x 22 x 700 700 x 22 x 700
Front Panel
inch 27-9/16 x 7/8 x 27-9/16 27-9/16 x 7/8 x 27-9/16 27-9/16 x 7/8 x 27-9/16
Coil Rows x Columns x FPI 1 x 8 x 18 1 x 8 x 18 2 x 8 x 18
Face Area m2 0.21 0.21 0.21
Type Turbo Fan Turbo Fan Turbo Fan
Indoor Units

Motor Output x Number W 43 x 1 43 x 1 43 x 1


Running Current A 0.2 0.2 0.2
Fan Air Flow Rate(H / M / L) CMM 7.5 / 7.0 / 6.6 7.5 / 7.0 / 6.6 8.0 / 7.5 / 7.1
cfm 265 / 247 / 212 265 / 247 / 212 283 / 265 / 251
Drive Direct Direct Direct
Motor type BLDC BLDC BLDC
Temperature Control Microprocessor, Microprocessor, Microprocessor,
Thermostat for cooling Thermostat for cooling Thermostat for cooling
and heating and heating and heating
Sound Absorbing Thermal Insulation Material Foamed polystrene Foamed polystrene Foamed polystrene
Safety Device Fuse Fuse Fuse
Liquid Side mm(inch) Ø6.35(1/4) Ø6.35(1/4) Ø6.35(1/4)
Pipe Connections Gas Side mm(inch) Ø12.7(1/2) Ø12.7(1/2) Ø12.7(1/2)
Drain Pipe(Internal Dia.) mm(inch) 25(1) 25(1) 25(1)
Net Weight Body kg(lbs) 13.1(28.9) 13.1(28.9) 14.2(31.3)
Packaged kg(lbs) 15.4(33.9) 15.4(33.9) 16.5(36.3)
Noise Level(Sound Press, 1.5m, H / M / L) dB(A) 29 / 27 / 26 29 / 27 / 26 30 / 29 / 27
Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50
1, 220, 60 1, 220, 60 1, 220, 60
Refrigerant Control EEV EEV EEV
Power cable mm2 CV1.5 x 3C CV1.5 x 3C CV1.5 x 3C
Transmission cable mm2 CVV-SB 1.0~1.5 x 2C CVV-SB 1.0~1.5 x 2C CVV-SB 1.0~1.5 x 2C
Panel Color Morning fog Morning fog Morning fog
Panel Name(Accessory) PT-UQC
Notes:-
1. Capacities are based on the following conditions: Conversion Formula
Cooling • Indoor temp. 27°C[80.6°F]DB/ 19°C[66.2°F]WB
• Outdoor temp. 35°C[95°F]DB/ 24°C[75.2°F]WB kcal/h= kW x 860
• Interconnecting Piping Length 7.5m Btu/h = kW x 3412
• Level Difference of Zero cfm = m3/min x 35.3
Heating • Indoor temp. 20°C[68°F]DB/ 15°C[59°F]WB l/s = CMM x 1000/60
• Outdoor temp. 7°C[44.6°F]DB/ 6°C[42.8°F]WB
• Interconnecting Piping Length 7.5m
• Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve
6. Anechoic chamber conversion value is measured at 1.5 m downward from unit centre.
The values depends on the ambient conditions and values are normally higher in actual operation.

2 _ Ceiling Cassette 4-way


2. Specifications
* Model Name
A:Basic, C:Plasma

Type 4 Way Ceiling Cassette


Model Unit ARNU12GTR*2 ARNU15GTQ*2 ARNU18GTQ*2
kW 3.6 4.5 5.6
Cooling Capacity kcal/h 3,100 3,900 4,800
Btu/h 12,300 15,400 19,100
kW 4.0 5.0 6.3
Heating Capacity kcal/h 3,400 4,300 5,400
Btu/h 13,600 17,100 21,500
Casing Galvanized Steel Plate Galvanized Steel Plate Galvanized Steel Plate
mm 570 x 214 x 570 570 x 256 x 570 570 x 256 x 570
Body
inch 22-7/16 x 8-7/16 x 22-7/16 22-7/16 x 10-3/32 x 22-7/16 22-7/16 x 10-3/32 x 22-7/16
Dimensions(WxHxD)
mm 700 x 22 x 700 700 x 22 x 700 700 x 22 x 700
Front Panel
inch 27-9/16 x 7/8 x 27-9/16 27-9/16 x 7/8 x 27-9/16 27-9/16 x 7/8 x 27-9/16
Coil Rows x Columns x FPI 2 x 8 x 18 2 x 10 x 18 2 x 10 x 18
Face Area m2 0.21 0.27 0.27
Type Turbo Fan Turbo Fan Turbo Fan

Indoor Units
Motor Output x Number W 43 x 1 43 x 1 43 x 1
Running Current A 0.2 0.2 0.2
Fan Air Flow Rate(H / M / L) CMM 8.7 / 8.0 / 7.0 11.0 / 10.0 / 9.3 11.2 / 11.0 / 10.0
cfm 307 / 283 / 247 388 / 353 / 328 396 / 388 / 353
Drive Direct Direct Direct
Motor type BLDC BLDC BLDC
Temperature Control Microprocessor, Microprocessor, Microprocessor,
Thermostat for cooling Thermostat for cooling Thermostat for cooling
and heating and heating and heating
Sound Absorbing Thermal Insulation Material Foamed polystrene Foamed polystrene Foamed polystrene
Safety Device Fuse Fuse Fuse
Liquid Side mm(inch) Ø6.35(1/4) Ø6.35(1/4) Ø6.35(1/4)
Pipe Connections Gas Side mm(inch) Ø12.7(1/2) Ø12.7(1/2) Ø12.7(1/2)
Drain Pipe(Internal Dia.) mm(inch) 25(1) 25(1) 25(1)
Net Weight Body kg(lbs) 14.2(31.3) 15.5(34.2) 15.5(34.2)
Packaged kg(lbs) 16.5(36.3) 18.0(39.7) 18.0(39.7)
Noise Level(Sound Press, 1.5m, H / M / L) dB(A) 32 / 30 / 27 36 / 34 / 32 37 / 35 / 34
Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50
1, 220, 60 1, 220, 60 1, 220, 60
Refrigerant Control EEV EEV EEV
Power cable mm2 CV1.5 x 3C CV1.5 x 3C CV1.5 x 3C
Transmission cable mm2 CVV-SB 1.0~1.5 x 2C CVV-SB 1.0~1.5 x 2C CVV-SB 1.0~1.5 x 2C
Panel Color Morning fog Morning fog Morning fog
Panel Name(Accessory) PT-UQC
Notes:-
1. Capacities are based on the following conditions: Conversion Formula
Cooling • Indoor temp. 27°C[80.6°F]DB/ 19°C[66.2°F]WB kcal/h= kW x 860
• Outdoor temp. 35°C[95°F]DB/ 24°C[75.2°F]WB
Btu/h = kW x 3412
• Interconnecting Piping Length 7.5m
cfm = m3/min x 35.3
• Level Difference of Zero
l/s = CMM x 1000/60
Heating • Indoor temp. 20°C[68°F]DB/ 15°C[59°F]WB
• Outdoor temp. 7°C[44.6°F]DB/ 6°C[42.8°F]WB
• Interconnecting Piping Length 7.5m
• Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve
6. Anechoic chamber conversion value is measured at 1.5 m downward from unit centre.
The values depends on the ambient conditions and values are normally higher in actual operation.

Ceiling Cassette 4-way _ 3


2. Specifications
* Model Name
A:Basic, C:Plasma

Type 4 Way Ceiling Cassette


Model Unit
ARNU24GTP*2 ARNU28GTP*2 ARNU36GTN*2
Cooling Capacity kW 7.1 8.2 10.6
kcal/h
6,100 7,100 9,100
Btu/h
24,200 28,000 36,200
Heating Capacity kW 8.0 9.2 11.9
kcal/h
6,900 8,000 10,200
Btu/h
27,300 31,500 40,600
Casing Galvanized Steel Plate Galvanized Steel Plate Galvanized Steel Plate
Dimensions Body mm 840 x 204 x 840 840 x 204 x 840 840 x 246 x 840
(WxHxD) inch 33-1/16 x 8-1/32 x 33-1/16 33-1/16 x 8-1/32 x 33-1/16 33-1/16 x 9-11/16 x 33-1/16
Front Panel mm 950 x 25 x 950 950 x 25 x 950 950 x 25 x 950
inch 37-13/32 x 31/32 x 37-13/32 37-13/32 x 31/32 x 37-13/32 37-13/32 x 31/32 x 37-13/32
Coil Rows x Columns x FPI 2 x 8 x 19 2 x 8 x 19 2x10x19
Face Area m2 0.40 0.40 0.57
Fan Type Turbo Fan Turbo Fan Turbo Fan
Indoor Units

Motor Outputx Number W 30 30 135


Running Current A 0.15 0.15 0.56
Air Flow Rate(H / M / L) CMM 17 / 15 / 13 19 / 16 / 14 25 / 21 / 19
cfm 600 / 529 / 459 671 / 565 / 494 883 / 742 / 671
Drive Direct Direct Direct
Motor type BLDC BLDC BLDC
Temperature Control Microprocessor, Thermostat for cooling and heating
Sound Absorbing Thermal Insulation Material Foamed polystrene Foamed polystrene Foamed polystrene
Safety Device Fuse Fuse Fuse
Pipe Liquid Side mm(inch) Ø9.52(3/8) Ø9.52(3/8) Ø9.52(3/8)
Connections Gas Side mm(inch) Ø15.88(5/8) Ø15.88(5/8) Ø15.88(5/8)
Drain Pipe(Internal Dia.) mm(inch) 25(1) 25(1) 25(1)
Net Weight Body kg(lbs) 20.8(45.8) 20.8(45.8) 23.5(51.8)
Noise Level (Sound Press, 1.5m, H / M / L) dB(A) 36 / 34 / 31 39 / 35 / 33 43 / 40 / 37
Power Supply 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50
Ø, V, Hz
1, 220, 60 1, 220, 60 1, 220, 60
Refrigerant Control EEV EEV EEV
Power cord CV2.0 X 3C CV2.0 X 3C CV2.0 X 3C
Transmission cable CVV-SB 1.0~1.5 X 2C CVV-SB 1.0~1.5 X 2C CVV-SB 1.0~1.5 X 2C
Panel Color Morning fog Morning fog Morning fog
Panel Name(Accessory) PT-UMC(1)
Elevation Grill(Accessory) PTEGM0

Notes:-
1. Capacities are based on the following conditions: Conversion Formula
Cooling • Indoor temp. 27°C[80.6°F]DB/ 19°C[66.2°F]WB kcal/h= kW x 860
• Outdoor temp. 35°C[95°F]DB/ 24°C[75.2°F]WB Btu/h = kW x 3412
• Interconnecting Piping Length 7.5m cfm = m3/min x 35.3
• Level Difference of Zero l/s = CMM x 1000/60
Heating • Indoor temp. 20°C[68°F]DB/ 15°C[59°F]WB
• Outdoor temp. 7°C[44.6°F]DB/ 6°C[42.8°F]WB
• Interconnecting Piping Length 7.5m
• Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve
6. Anechoic chamber conversion value is measured at 1.5 m downward from unit centre.
The values depends on the ambient conditions and values are normally higher in actual operation.

4 _ Ceiling Cassette 4-way


2. Specifications
* Model Name
A:Basic, C:Plasma
Type 4 Way Ceiling Cassette
Model Unit ARNU42GTM*2 ARNU48GTM*2
Cooling Capacity kW 12.3 14.1
kcal/h 10,600 12,100
Btu/h 42,000 48,100
Heating Capacity kW 13.8 15.9
kcal/h 11,000 13,200
Btu/h 43,800 51,200
Casing Galvanized Steel Plate Galvanized Steel Plate
Dimensions Body mm 840 x 288 x 840 840 x 288 x 840
(WxHxD) inch 33-1/16 x 11-11/32 x 33-1/16 33-1/16 x 11-11/32 x 33-1/16
Front Panel mm 950 x 25 x 950 950 x 25 x 950
inch 37-13/32 x 31/32 x 37-13/32 37-13/32 x 31/32 x 37-13/32
Coil Rows x Columns x FPI 2 x 12 x 19 2 x 12 x 19
Face Area m2 0.57 0.57

Indoor Units
Fan Type Turbo Fan Turbo Fan
Motor Outputx Number W 135 135
Running Current A 0.56 0.56
Air Flow Rate(H / M / L) CMM 30 / 27 / 24 31 / 29 / 27
cfm 1,059 / 954 / 848 1,095 / 1,024 / 954
Drive Direct Direct
Motor type BLDC BLDC
Temperature Control Microprocessor, Thermostat for cooling and heating
Sound Absorbing Thermal Insulation Material Foamed polystrene Foamed polystrene
Safety Device Fuse Fuse
Pipe Liquid Side mm(inch) Ø9.52(3/8) Ø9.52(3/8)
Connections Gas Side mm(inch) Ø15.88(5/8) Ø15.88(5/8)
Drain Pipe(Internal Dia.) mm(inch) 25(1) 25(1)
Net Weight Body kg(lbs) 25.6(56.4) 25.6(56.4)
Noise Level (Sound Press, 1.5m, H / M / L) dB(A) 44 / 41 / 38 46 / 43 / 41
Power Supply 1, 220-240, 50 1, 220-240, 50
Ø, V, Hz
1, 220, 60 1, 220, 60
Refrigerant Control EEV EEV
Power cord CV2.0 X 3C CV2.0 X 3C
Transmission cable CVV-SB 1.0~1.5 X 2C CVV-SB 1.0~1.5 X 2C
Panel Color Morning fog Morning fog
Panel Name(Accessory) PT-UMC(1)
Elevation Grill(Accessory) PTEGM0
Notes:-
1. Capacities are based on the following conditions:
Cooling • Indoor temp. 27°C[80.6°F]DB/ 19°C[66.2°F]WB
• Outdoor temp. 35°C[95°F]DB/ 24°C[75.2°F]WB Conversion Formula
• Interconnecting Piping Length 7.5m kcal/h= kW x 860
• Level Difference of Zero Btu/h = kW x 3412
Heating • Indoor temp. 20°C[68°F]DB/ 15°C[59°F]WB cfm = m3/min x 35.3
• Outdoor temp. 7°C[44.6°F]DB/ 6°C[42.8°F]WB l/s = CMM x 1000/60
• Interconnecting Piping Length 7.5m
• Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve
6. Anechoic chamber conversion value is measured at 1.5 m downward from unit centre.
The values depends on the ambient conditions and values are normally higher in actual operation.

Ceiling Cassette 4-way _ 5


Indoor Units

R3
Ceiling Cassette 4-way
5

ARNU05GTR*2

128
4R20 ARNU07GTR*2
69
517
ARNU09GTR*2
4
5 ARNU12GTR*2
3. Dimensions

(unit : mm)
6

700
Number Name Descripition

6 _ Ceiling Cassette 4-way


517
570

523
1 Liquid pipe connection Unit size(5k, 7k, 9k, 12k):ø6.35

376(Inlet Grille)
2 Gas pipe connection Unit size(5k, 7k, 9k, 12k):ø12.7
3 Drain pipe connection VP25(Φ32)
4 Power supply connection

461
5 Air discharge grill
380(Air outlet hole) 570
473 6 Air suction grill
2 1
700
165
Note
1. Unit should be installed in compliance with the installation manual

59.5
214

22
79
in the product box.

84.5
48
53
2. Unit shall be grounded in accordance with the local regulations or

34.5
30 19 63 applicable national codes.
142.5
570
3
Branch Duct Connection

• REQUIRED SPACE

B
CEILING OPENING
500mm or more*

500mm or more*
500mm or more*

500mm or more*

A ARROW VIEW B ARROW VIEW


A

76, Seongsan-dong, Changwon City, Gyeongnam,


641-713, Korea CHASSIS CODE: TR
R3
5
Ceiling Cassette 4-way
ARNU15GTQ*2

174
4R20
ARNU18GTQ*2
68

517
4
5
3. Dimensions

(unit : mm)
Number Name Descripition
6

700
517
570

523
1 Liquid pipe connection Unit size(15k, 18k):Ø6.35

376(Inlet Grille)
2 Gas pipe connection Unit size(15k, 18k):Ø12.7
3 Drain pipe connection VP25(Φ32)
4 Power supply connection
461 5 Air discharge grill
570

2 1
6 Air suction grill
380(Air outlet hole)
473
Note
700
165
1. Unit should be installed in compliance with the installation manual

59.5
in the product box.

256

22
79

125
2. Unit shall be grounded in accordance with the local regulations or

95.5
94
76

48
applicable national codes.
30 19 63
142.5
570

3 Branch Duct Connection

• REQUIRED SPACE 500mm or more*

CEILING OPENING

B
500mm or more*
500mm or more*

500mm or more*

A
A ARROW VIEW B ARROW VIEW

76, Seongsan-dong, Changwon City, Gyeongnam,


641-713, Korea CHASSIS CODE: TQ

Ceiling Cassette 4-way _ 7


Indoor Units
Indoor Units

4-R20 Ceiling Cassette 4-way


5
804 ARNU24GTP*2
ARNU28GTP*2

154
204
6

950
614(Inlet Grille)
787 (unit : mm)
3. Dimensions

Number Name Descripition

8 _ Ceiling Cassette 4-way


500(Air outlet Hole)
1 Liquid pipe connection Unit size(24k, 28k):ø9.52
737 2 Gas pipe connection Unit size(24k, 28k):ø15.88
950

25
3 Drain pipe connection VP25(Φ32)
4 Power supply connection

671
684
840
5 Air discharge grill
870-920(CEILING OPENING SPACE)
786(SUSPENSION POSITION) 6 Air suction grill

300
OR LESS
Note

420
393
420
1. Unit should be installed in compliance with the installation manual
Ceiling opening A in the product box.
2. Unit shall be grounded in accordance with the local regulations or
787
applicable national codes.

682(SUSPENSION POSITION)

669(SUSPENSION POSITION)
840

870-920(CEILING OPENING SPACE)


475
B

71 OUTDOOR AIR INTAKE BRANCH DUCT


1 92 92 92 92 CONNECTION • REQUIRED SPACE
(DIRECT CONNECTION) 4 BRANCH DUCT
31 35 CONNECTION 50
350 500mm or more*
165

79
32

26
50

62
79

500mm or more*
50

204

500mm or more*

71
82
99
60

65 40
ø70 13-ø 3, 3 Hole
108 60 80

41.5
840 53.5
2 3 500mm or more*
13-ø 3, 3 Hole 165 165
10
Branch Duct Connection 350

A ARROW VIEW

B ARROW VIEW

76, Seongsan-dong, Changwon City, Gyeongnam,


641-713, Korea CHASSIS CODE: TP
4-R20
Ceiling Cassette 4-way
840
5

195
ARNU36GTN*2

246
6

950
614(Inlet Grille)
3. Dimensions

(unit : mm)
Number Name Descripition

500(Air outlet Hole) 1 Liquid pipe connection Unit size(36k):ø9.52


737
950 2 Gas pipe connection Unit size(36k):ø15.88
3 Drain pipe connection

25
VP25(Φ32)
4 Power supply connection
870-920(CEILING OPENING SPACE) 5 Air discharge grill
786(SUSPENSION POSITION)

300
OR LESS
6 Air suction grill
Note

420
393
420
1. Unit should be installed in compliance with the installation manual
Ceiling opening A in the product box.
2. Unit shall be grounded in accordance with the local regulations or
applicable national codes.

682(SUSPENSION POSITION)

669(SUSPENSION POSITION)
870-920(CEILING OPENING SPACE)
475
B

71 OUTDOOR AIR INTAKE


31 35 (DIRECT CONNECTION)
4 BRANCH DUCT
1 350 CONNECTION 92 92 92 92 • REQUIRED SPACE
165 BRANCH DUCT

44
CONNECTION

80
43

500mm or more*
ø70

71
60

40
246
100

100
500mm or more*
60

141
500mm or more*

107
103
78

52
13-ø 3, 3 Hole
2 110 60 80 3
840 53.5 13-ø 3, 3 Hole

165 10 165 500mm or more*


Branch Duct Connection
350

A ARROW VIEW

B ARROW VIEW

76, Seongsan-dong, Changwon City, Gyeongnam,


641-713, Korea CHASSIS CODE: TN

Ceiling Cassette 4-way _ 9


Indoor Units
Indoor Units

4-R20
Ceiling Cassette 4-way
5

ARNU42GTM*2
ARNU48GTM*2
840

950
237

288

614(Inlet Grille)
(unit : mm)
3. Dimensions

Number Name Descripition


1 Liquid pipe connection Unit size(42k, 48k):ø9.52

10 _ Ceiling Cassette 4-way


500(Air outlet Hole)
737
2 Gas pipe connection Unit size(42k, 48k):ø15.88
950
3 Drain pipe connection VP25(Φ32)

25
4 Power supply connection
5 Air discharge grill
870-920(CEILING OPENING SPACE)
786(SUSPENSION POSITION)
6 Air suction grill

300
OR LESS
Note

420
393
420
1. Unit should be installed in compliance with the installation manual
Ceiling opening in the product box.
A
2. Unit shall be grounded in accordance with the local regulations or
applicable national codes.

682(SUSPENSION POSITION)

669(SUSPENSION POSITION)
870-920(CEILING OPENING SPACE)
475
B
71
OUTDOOR AIR INTAKE 92 92 92 92
31 35
4
(DIRECT CONNECTION) 350 • REQUIRED SPACE
1
165
BRANCH DUCT

100
76

CONNECTION 500mm or more*


136

75
110
60

ø70
100

500mm or more*
60

500mm or more*

71
BRANCH DUCTCONNECTION

84
53.5
13-ø 3, 3 Hole 3 13-ø 3, 3 Hole

2 500mm or more*
165 10 165
Branch Duct Connection
350

A ARROW VIEW

B ARROW VIEW

76, Seongsan-dong, Changwon City, Gyeongnam,


641-713, Korea CHASSIS CODE: TM
4. Piping Diagrams

:Cooling
Heat Exchanger EEV :Heating
Filter
Th3 Th2
Turbo Fan Filter

Th1 lndoor unit

Indoor Units
Refrigerant pipe connection port diameter

[Unit: mm(inch)]

Model Gas Liquid

ARNU05GTR*2 Ø12.7(1/2) Ø6.35(1/4)

ARNU07GTR*2 Ø12.7(1/2) Ø6.35(1/4)

ARNU09GTR*2 Ø12.7(1/2) Ø6.35(1/4)

ARNU12GTR*2 Ø12.7(1/2) Ø6.35(1/4)

ARNU15GTQ*2 Ø12.7(1/2) Ø6.35(1/4)

ARNU18GTQ*2 Ø12.7(1/2) Ø6.35(1/4)

ARNU24GTP*2 Ø15.88(5/8) Ø9.52(3/8)

ARNU28GTP*2 Ø15.88(5/8) Ø9.52(3/8)

ARNU36GTN*2 Ø15.88(5/8) Ø9.52(3/8)

ARNU42GTM*2 Ø15.88(5/8) Ø9.52(3/8)

ARNU48GTM*2 Ø15.88(5/8) Ø9.52(3/8)

LOC. Description
Th1 Room thermistor
Th2 Pipe in thermistor
Th3 Pipe out thermistor

Ceiling Cassette 4-way _ 11


5. Wiring Diagrams
TR/TQ Chassis
Indoor Units

CONNECTOR NUMBER LOCATION POINT FUNCTION


CN-POWER AC Power supply AC Power line input for indoor controller
CN-MOTOR1 Fan motor output Motor output of BLDC
CN-D/PUMP Drain pump output AC output for drain pump
CN-485 Communication Connection between indoor and outdoor
CN-DISP Display Display of indoor status
CN-EEV EEV Output EEV Control output
CN-VANE2 Step motor Step motor output
CN-FLOAT Float switch input Float switch sensing
CN-PIPE/IN Suction pipe sensor Pipe in thermistor
CN-PIPE/OUT Discharge pipe sensor Pipe out thermistor
CN-ROOM Room sensor Room air thermistor
CN-REMO Remote controller Remote control line
CN-CC Dry contact Dry contact line
CN-AIRC Air clean Air cleaner control

Dip Switch Setting Off On Remarks


SW3 GROUP Master Slave Group Control setting using Wired Remote Controller
Old Dry Contact Mode Setting
1. Variable : Auto/Manual Mode can be chosen by Wide wired
SW4 DRY CONTACT Variable Auto remote controller or Wireless remote controller
(When shipped from Factory ’ Manual Mode)
2. Auto : For Dry Contact, it is always Auto mode.
1. Duct model
-. OFF : Default(not operate continuosly )
-. ON : Fan operate continuosly
SW5 EXTRA 1 Off On 2. Cassette Model : No Function
3. Ceiling Suspended Model
-. OFF : Ceiling(default)
-. ON : Floor

CAUTION
For Multi V Model, Dip Switch 1,2,6,7,8 must be set OFF
That dip switch is used for the other model.

12 _ Ceiling Cassette 4-way


5. Wiring Diagrams
TM/TN/TP Chassis

Indoor Units
CONNECTOR NUMBER LOCATION POINT FUNCTION
CN-POWER AC Power supply AC Power line input for indoor controller
CN-MOTOR1 Fan motor output Motor output of BLDC
CN-D/PUMP Drain pump output AC output for drain pump
CN-485 Communication Connection between indoor and outdoor
CN-DISP Display Display of indoor status
CN-EEV EEV Output EEV Control output
CN-VANE1 / VANE2 Step motor Step motor output
CN-FLOAT Float switch input Float switch sensing
CN-PIPE/IN Suction pipe sensor Pipe in thermistor
CN-PIPE/OUT Discharge pipe sensor Pipe out thermistor
CN-ROOM Room sensor Room air thermistor
CN-REMO Remote controller Remote control line
CN-CC Dry contact Dry contact line
CN-AIRC Air clean Air cleaner control
Dip Switch Setting Off On Remarks
SW3 GROUP Master Slave Group Control setting using Wired Remote Controller
Old Dry Contact Mode Setting
1. Variable : Auto/Manual Mode can be chosen by Wide wired
SW4 DRY CONTACT Variable Auto remote controller or Wireless remote controller
(When shipped from Factory ’ Manual Mode)
2. Auto : For Dry Contact, it is always Auto mode.
1. Duct model
-. OFF : Default(not operate continuosly )
-. ON : Fan operate continuosly
SW5 EXTRA 1 Off On 2. Cassette Model : No Function
3. Ceiling Suspended Model
-. OFF : Ceiling(default)
-. ON : Floor

CAUTION
For Multi V Model, Dip Switch 1,2,6,7,8 must be set OFF
That dip switch is used for the other model.

Ceiling Cassette 4-way _ 13


6. Capacity Tables
6.1 Cooling Capacity Cooling capacity

Indoor air temp. (DB/WB, °C)


Capacity Outdoor 20 23 26 27 28 30 32
Index air temp. 14 16 18 19 20 22 24
(DB, °C) TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10 1.1 1.0 1.3 1.1 1.5 1.2 1.6 1.2 1.7 1.2 1.9 1.3 2.1 1.3
12 1.1 1.0 1.3 1.1 1.5 1.2 1.6 1.2 1.7 1.2 1.9 1.3 2.1 1.3
14 1.1 1.0 1.3 1.1 1.5 1.2 1.6 1.2 1.7 1.2 1.9 1.3 2.1 1.2
16 1.1 1.0 1.3 1.1 1.5 1.2 1.6 1.2 1.7 1.2 1.9 1.3 2.0 1.2
18 1.1 1.0 1.3 1.1 1.5 1.2 1.6 1.2 1.7 1.2 1.9 1.3 2.0 1.2
20 1.1 1.0 1.3 1.1 1.5 1.2 1.6 1.2 1.7 1.2 1.9 1.3 2.0 1.2
21 1.1 1.0 1.3 1.1 1.5 1.2 1.6 1.2 1.7 1.2 1.9 1.3 2.0 1.2
23 1.1 1.0 1.3 1.1 1.5 1.2 1.6 1.2 1.7 1.2 1.9 1.3 1.9 1.2
1.6 25 1.1 1.0 1.3 1.1 1.5 1.2 1.6 1.2 1.7 1.2 1.9 1.3 1.9 1.2
27 1.1 1.0 1.3 1.1 1.5 1.2 1.6 1.2 1.7 1.2 1.8 1.2 1.9 1.2
29 1.1 1.0 1.3 1.1 1.5 1.2 1.6 1.2 1.7 1.2 1.8 1.2 1.8 1.1
Indoor Units

31 1.1 1.0 1.3 1.1 1.5 1.2 1.6 1.2 1.7 1.2 1.8 1.2 1.8 1.1
33 1.1 1.0 1.3 1.1 1.5 1.2 1.6 1.2 1.7 1.2 1.8 1.2 1.8 1.1
35 1.1 1.0 1.3 1.1 1.5 1.2 1.6 1.2 1.7 1.2 1.7 1.2 1.8 1.1
37 1.1 1.0 1.3 1.1 1.5 1.2 1.6 1.2 1.7 1.2 1.7 1.2 1.7 1.1
39 1.1 1.0 1.3 1.1 1.5 1.2 1.6 1.2 1.6 1.2 1.7 1.1 1.7 1.0
10 1.5 1.4 1.8 1.5 2.0 1.7 2.2 1.7 2.4 1.8 2.6 1.8 2.9 1.8
12 1.5 1.4 1.8 1.5 2.0 1.7 2.2 1.7 2.4 1.8 2.6 1.8 2.9 1.8
14 1.5 1.4 1.8 1.5 2.0 1.7 2.2 1.7 2.4 1.8 2.6 1.8 2.8 1.8
16 1.5 1.4 1.8 1.5 2.0 1.7 2.2 1.7 2.4 1.8 2.6 1.8 2.8 1.7
18 1.5 1.4 1.8 1.5 2.0 1.7 2.2 1.7 2.4 1.8 2.6 1.8 2.7 1.7
20 1.5 1.4 1.8 1.5 2.0 1.7 2.2 1.7 2.4 1.8 2.6 1.8 2.7 1.7
21 1.5 1.4 1.8 1.5 2.0 1.7 2.2 1.7 2.4 1.8 2.6 1.8 2.7 1.7
23 1.5 1.4 1.8 1.5 2.0 1.7 2.2 1.7 2.4 1.8 2.6 1.8 2.6 1.7
2.2 25 1.5 1.4 1.8 1.5 2.0 1.7 2.2 1.7 2.4 1.8 2.6 1.8 2.6 1.6
27 1.5 1.4 1.8 1.5 2.0 1.7 2.2 1.7 2.4 1.8 2.5 1.8 2.6 1.6
29 1.5 1.4 1.8 1.5 2.0 1.7 2.2 1.7 2.4 1.8 2.5 1.7 2.5 1.6
31 1.5 1.4 1.8 1.5 2.0 1.7 2.2 1.7 2.4 1.8 2.5 1.7 2.5 1.6
33 1.5 1.4 1.8 1.5 2.0 1.7 2.2 1.7 2.4 1.8 2.4 1.7 2.4 1.5
35 1.5 1.4 1.8 1.5 2.0 1.7 2.2 1.7 2.4 1.8 2.4 1.7 2.4 1.5
37 1.5 1.4 1.8 1.5 2.0 1.7 2.2 1.7 2.3 1.7 2.3 1.6 2.4 1.5
39 1.5 1.4 1.8 1.5 2.0 1.7 2.2 1.7 2.2 1.7 2.3 1.6 2.4 1.5
10 1.9 1.6 2.2 1.8 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.7 2.1
12 1.9 1.6 2.2 1.8 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.6 2.1
14 1.9 1.6 2.2 1.8 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.6 2.1
16 1.9 1.6 2.2 1.8 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.5 2.0
18 1.9 1.6 2.2 1.8 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.5 2.0
20 1.9 1.6 2.2 1.8 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.4 2.0
21 1.9 1.6 2.2 1.8 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.4 2.0
23 1.9 1.6 2.2 1.8 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.4 2.0
2.8 25 1.9 1.6 2.2 1.8 2.6 2.0 2.8 2.0 3.0 2.1 3.3 2.1 3.3 1.9
27 1.9 1.6 2.2 1.8 2.6 2.0 2.8 2.0 3.0 2.1 3.2 2.1 3.3 1.9
29 1.9 1.6 2.2 1.8 2.6 2.0 2.8 2.0 3.0 2.1 3.2 2.0 3.2 1.9
31 1.9 1.6 2.2 1.8 2.6 2.0 2.8 2.0 3.0 2.1 3.2 2.0 3.2 1.8
33 1.9 1.6 2.2 1.8 2.6 2.0 2.8 2.0 3.0 2.1 3.1 2.0 3.1 1.8
35 1.9 1.6 2.2 1.8 2.6 2.0 2.8 2.0 3.0 2.1 3.0 2.0 3.1 1.8
37 1.9 1.6 2.2 1.8 2.6 2.0 2.8 2.0 2.9 2.0 3.0 1.9 3.0 1.8
39 1.9 1.6 2.2 1.8 2.6 2.0 2.8 2.0 2.8 2.0 2.9 1.9 3.0 1.7

14 _ Ceiling Cassette 4-way


6. Capacity Tables
Cooling capacity

Indoor air temp. (DB/WB, °C)


Capacity Outdoor 20 23 26 27 28 30 32
Index air temp. 14 16 18 19 20 22 24
(DB, °C) TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10 2.4 2.1 2.9 2.3 3.3 2.5 3.6 2.5 3.9 2.6 4.3 2.7 4.7 2.6
12 2.4 2.1 2.9 2.3 3.3 2.5 3.6 2.5 3.9 2.6 4.3 2.7 4.7 2.6
14 2.4 2.1 2.9 2.3 3.3 2.5 3.6 2.5 3.9 2.6 4.3 2.7 4.6 2.6
16 2.4 2.1 2.9 2.3 3.3 2.5 3.6 2.5 3.9 2.6 4.3 2.7 4.6 2.5
18 2.4 2.1 2.9 2.3 3.3 2.5 3.6 2.5 3.9 2.6 4.3 2.7 4.5 2.5
20 2.4 2.1 2.9 2.3 3.3 2.5 3.6 2.5 3.9 2.6 4.3 2.7 4.4 2.5
21 2.4 2.1 2.9 2.3 3.3 2.5 3.6 2.5 3.9 2.6 4.3 2.7 4.4 2.5
23 2.4 2.1 2.9 2.3 3.3 2.5 3.6 2.5 3.9 2.6 4.3 2.7 4.3 2.5
3.6 25 2.4 2.1 2.9 2.3 3.3 2.5 3.6 2.5 3.9 2.6 4.3 2.6 4.3 2.4
27 2.4 2.1 2.9 2.3 3.3 2.5 3.6 2.5 3.9 2.6 4.2 2.6 4.2 2.4
29 2.4 2.1 2.9 2.3 3.3 2.5 3.6 2.5 3.9 2.6 4.1 2.5 4.2 2.4

Indoor Units
31 2.4 2.1 2.9 2.3 3.3 2.5 3.6 2.5 3.9 2.6 4.1 2.5 4.1 2.3
33 2.4 2.1 2.9 2.3 3.3 2.5 3.6 2.5 3.9 2.6 4.0 2.5 4.0 2.3
35 2.4 2.1 2.9 2.3 3.3 2.5 3.6 2.5 3.9 2.6 3.9 2.5 4.0 2.3
37 2.4 2.1 2.9 2.3 3.3 2.5 3.6 2.5 3.8 2.5 3.8 2.4 3.9 2.2
39 2.4 2.1 2.9 2.3 3.3 2.5 3.6 2.5 3.7 2.5 3.8 2.4 3.9 2.2
10 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.6 5.9 3.5
12 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.6 5.8 3.5
14 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.6 5.8 3.4
16 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.6 5.7 3.4
18 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.6 5.6 3.4
20 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.6 5.5 3.3
21 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.6 5.5 3.3
23 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.6 5.4 3.2
4.5 25 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.3 3.5 5.3 3.2
27 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.2 3.4 5.3 3.2
29 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.1 3.4 5.2 3.1
31 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.1 3.3 5.1 3.0
33 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 4.9 3.3 5.0 3.0
35 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 4.9 3.2 4.9 3.0
37 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.7 3.3 4.8 3.2 4.9 2.9
39 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.6 3.2 4.7 3.1 4.8 2.8
10 3.8 3.2 4.5 3.5 5.2 3.8 5.6 3.9 6.0 4.1 6.7 4.2 7.3 4.1
12 3.8 3.2 4.5 3.5 5.2 3.8 5.6 3.9 6.0 4.1 6.7 4.2 7.3 4.1
14 3.8 3.2 4.5 3.5 5.2 3.8 5.6 3.9 6.0 4.1 6.7 4.2 7.2 4.1
16 3.8 3.2 4.5 3.5 5.2 3.8 5.6 3.9 6.0 4.1 6.7 4.2 7.1 4.0
18 3.8 3.2 4.5 3.5 5.2 3.8 5.6 3.9 6.0 4.1 6.7 4.2 6.9 4.0
20 3.8 3.2 4.5 3.5 5.2 3.8 5.6 3.9 6.0 4.1 6.7 4.2 6.9 3.9
21 3.8 3.2 4.5 3.5 5.2 3.8 5.6 3.9 6.0 4.1 6.7 4.2 6.9 3.9
23 3.8 3.2 4.5 3.5 5.2 3.8 5.6 3.9 6.0 4.1 6.7 4.2 6.7 3.8
5.6 25 3.8 3.2 4.5 3.5 5.2 3.8 5.6 3.9 6.0 4.1 6.6 4.1 6.6 3.7
27 3.8 3.2 4.5 3.5 5.2 3.8 5.6 3.9 6.0 4.1 6.5 4.1 6.5 3.7
29 3.8 3.2 4.5 3.5 5.2 3.8 5.6 3.9 6.0 4.1 6.4 4.0 6.5 3.7
31 3.8 3.2 4.5 3.5 5.2 3.8 5.6 3.9 6.0 4.1 6.3 3.9 6.4 3.6
33 3.8 3.2 4.5 3.5 5.2 3.8 5.6 3.9 6.0 4.1 6.2 3.9 6.2 3.5
35 3.8 3.2 4.5 3.5 5.2 3.8 5.6 3.9 6.0 4.1 6.1 3.8 6.2 3.5
37 3.8 3.2 4.5 3.5 5.2 3.8 5.6 3.9 5.8 3.9 5.9 3.7 6.1 3.4
39 3.8 3.2 4.5 3.5 5.2 3.8 5.6 3.9 5.7 3.8 5.8 3.7 6.0 3.4

Ceiling Cassette 4-way _ 15


6. Capacity Tables
Cooling capacity

Indoor air temp. (DB/WB, °C)


Capacity Outdoor 20 23 26 27 28 30 32
Index air temp. 14 16 18 19 20 22 24
(DB, °C) TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 8.5 5.5 9.3 5.4
12 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 8.5 5.5 9.2 5.4
14 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 8.5 5.5 9.1 5.3
16 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 8.5 5.5 9.0 5.2
18 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 8.5 5.5 8.8 5.2
20 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 8.5 5.5 8.7 5.1
21 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 8.5 5.5 8.7 5.1
23 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 8.5 5.5 8.5 5.0
7.1 25 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 8.4 5.4 8.4 4.9
27 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 8.2 5.3 8.3 4.9
29 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 8.1 5.2 8.2 4.8
Indoor Units

31 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 8.0 5.1 8.1 4.7
33 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 7.8 5.1 7.9 4.6
35 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 7.7 5.0 7.8 4.6
37 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.4 5.1 7.5 4.9 7.7 4.5
39 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.2 5.0 7.4 4.8 7.6 4.4
10 5.5 4.9 6.6 5.4 7.7 5.8 8.2 5.9 8.7 6.1 9.8 6.4 10.8 6.3
12 5.5 4.9 6.6 5.4 7.7 5.8 8.2 5.9 8.7 6.1 9.8 6.4 10.6 6.2
14 5.5 4.9 6.6 5.4 7.7 5.8 8.2 5.9 8.7 6.1 9.8 6.4 10.5 6.1
16 5.5 4.9 6.6 5.4 7.7 5.8 8.2 5.9 8.7 6.1 9.8 6.4 10.4 6.1
18 5.5 4.9 6.6 5.4 7.7 5.8 8.2 5.9 8.7 6.1 9.8 6.4 10.2 6.0
20 5.5 4.9 6.6 5.4 7.7 5.8 8.2 5.9 8.7 6.1 9.8 6.4 10.1 5.9
21 5.5 4.9 6.6 5.4 7.7 5.8 8.2 5.9 8.7 6.1 9.8 6.4 10.0 5.8
23 5.5 4.9 6.6 5.4 7.7 5.8 8.2 5.9 8.7 6.1 9.8 6.4 9.9 5.8
8.2 25 5.5 4.9 6.6 5.4 7.7 5.8 8.2 5.9 8.7 6.1 9.7 6.3 9.7 5.7
27 5.5 4.9 6.6 5.4 7.7 5.8 8.2 5.9 8.7 6.1 9.4 6.1 9.6 5.6
29 5.5 4.9 6.6 5.4 7.7 5.8 8.2 5.9 8.7 6.1 9.3 6.1 9.5 5.5
31 5.5 4.9 6.6 5.4 7.7 5.8 8.2 5.9 8.7 6.1 9.2 5.9 9.3 5.4
33 5.5 4.9 6.6 5.4 7.7 5.8 8.2 5.9 8.7 6.1 9.0 5.8 9.2 5.4
35 5.5 4.9 6.6 5.4 7.7 5.8 8.2 5.9 8.7 6.1 8.9 5.7 9.0 5.3
37 5.5 4.9 6.6 5.4 7.7 5.8 8.2 5.9 8.5 5.9 8.7 5.6 8.9 5.2
39 5.5 4.9 6.6 5.4 7.7 5.8 8.2 5.9 8.4 5.8 8.5 5.5 8.8 5.1
10 7.2 6.3 8.5 6.9 9.9 7.5 10.6 7.6 11.3 7.9 12.7 8.2 13.9 8.1
12 7.2 6.3 8.5 6.9 9.9 7.5 10.6 7.6 11.3 7.9 12.7 8.2 13.7 8.0
14 7.2 6.3 8.5 6.9 9.9 7.5 10.6 7.6 11.3 7.9 12.7 8.2 13.6 7.9
16 7.2 6.3 8.5 6.9 9.9 7.5 10.6 7.6 11.3 7.9 12.7 8.2 13.4 7.8
18 7.2 6.3 8.5 6.9 9.9 7.5 10.6 7.6 11.3 7.9 12.7 8.2 13.2 7.7
20 7.2 6.3 8.5 6.9 9.9 7.5 10.6 7.6 11.3 7.9 12.7 8.2 13.0 7.6
21 7.2 6.3 8.5 6.9 9.9 7.5 10.6 7.6 11.3 7.9 12.7 8.2 12.9 7.6
23 7.2 6.3 8.5 6.9 9.9 7.5 10.6 7.6 11.3 7.9 12.7 8.2 12.8 7.5
10.6 25 7.2 6.3 8.5 6.9 9.9 7.5 10.6 7.6 11.3 7.9 12.5 8.1 12.6 7.3
27 7.2 6.3 8.5 6.9 9.9 7.5 10.6 7.6 11.3 7.9 12.2 7.9 12.4 7.3
29 7.2 6.3 8.5 6.9 9.9 7.5 10.6 7.6 11.3 7.9 12.1 7.8 12.2 7.1
31 7.2 6.3 8.5 6.9 9.9 7.5 10.6 7.6 11.3 7.9 11.9 7.7 12.0 7.0
33 7.2 6.3 8.5 6.9 9.9 7.5 10.6 7.6 11.3 7.9 11.7 7.6 11.8 6.9
35 7.2 6.3 8.5 6.9 9.9 7.5 10.6 7.6 11.3 7.9 11.4 7.4 11.7 6.8
37 7.2 6.3 8.5 6.9 9.9 7.5 10.6 7.6 11.0 7.7 11.2 7.3 11.5 6.7
39 7.2 6.3 8.5 6.9 9.9 7.5 10.6 7.6 10.8 7.5 11.0 7.1 11.3 6.6

16 _ Ceiling Cassette 4-way


6. Capacity Tables
Cooling capacity

Indoor air temp. (DB/WB, °C)


Capacity Outdoor 20 23 26 27 28 30 32
Index air temp. 14 16 18 19 20 22 24
(DB, °C) TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10 8.3 7.3 9.9 8.0 11.5 8.7 12.3 8.9 13.1 9.1 14.7 9.5 16.2 9.4
12 8.3 7.3 9.9 8.0 11.5 8.7 12.3 8.9 13.1 9.1 14.7 9.5 15.9 9.3
14 8.3 7.3 9.9 8.0 11.5 8.7 12.3 8.9 13.1 9.1 14.7 9.5 15.8 9.2
16 8.3 7.3 9.9 8.0 11.5 8.7 12.3 8.9 13.1 9.1 14.7 9.5 15.6 9.1
18 8.3 7.3 9.9 8.0 11.5 8.7 12.3 8.9 13.1 9.1 14.7 9.5 15.3 9.0
20 8.3 7.3 9.9 8.0 11.5 8.7 12.3 8.9 13.1 9.1 14.7 9.5 15.1 8.8
21 8.3 7.3 9.9 8.0 11.5 8.7 12.3 8.9 13.1 9.1 14.7 9.5 15.0 8.8
23 8.3 7.3 9.9 8.0 11.5 8.7 12.3 8.9 13.1 9.1 14.7 9.5 14.8 8.6
12.3 25 8.3 7.3 9.9 8.0 11.5 8.7 12.3 8.9 13.1 9.1 14.5 9.4 14.6 8.5
27 8.3 7.3 9.9 8.0 11.5 8.7 12.3 8.9 13.1 9.1 14.1 9.2 14.4 8.4
29 8.3 7.3 9.9 8.0 11.5 8.7 12.3 8.9 13.1 9.1 14.0 9.1 14.2 8.3

Indoor Units
31 8.3 7.3 9.9 8.0 11.5 8.7 12.3 8.9 13.1 9.1 13.8 8.9 14.0 8.2
33 8.3 7.3 9.9 8.0 11.5 8.7 12.3 8.9 13.1 9.1 13.5 8.8 13.7 8.0
35 8.3 7.3 9.9 8.0 11.5 8.7 12.3 8.9 13.1 9.1 13.3 8.6 13.5 7.9
37 8.3 7.3 9.9 8.0 11.5 8.7 12.3 8.9 12.8 8.9 13.0 8.4 13.4 7.8
39 8.3 7.3 9.9 8.0 11.5 8.7 12.3 8.9 12.5 8.7 12.8 8.3 13.1 7.7
10 9.5 8.3 11.3 9.2 13.2 10.0 14.1 10.2 15.0 10.5 16.9 10.9 18.5 10.8
12 9.5 8.3 11.3 9.2 13.2 10.0 14.1 10.2 15.0 10.5 16.9 10.9 18.3 10.7
14 9.5 8.3 11.3 9.2 13.2 10.0 14.1 10.2 15.0 10.5 16.9 10.9 18.1 10.6
16 9.5 8.3 11.3 9.2 13.2 10.0 14.1 10.2 15.0 10.5 16.9 10.9 17.8 10.4
18 9.5 8.3 11.3 9.2 13.2 10.0 14.1 10.2 15.0 10.5 16.9 10.9 17.6 10.3
20 9.5 8.3 11.3 9.2 13.2 10.0 14.1 10.2 15.0 10.5 16.9 10.9 17.3 10.1
21 9.5 8.3 11.3 9.2 13.2 10.0 14.1 10.2 15.0 10.5 16.9 10.9 17.2 10.1
23 9.5 8.3 11.3 9.2 13.2 10.0 14.1 10.2 15.0 10.5 16.9 10.9 17.0 9.9
14.1 25 9.5 8.3 11.3 9.2 13.2 10.0 14.1 10.2 15.0 10.5 16.6 10.8 16.7 9.8
27 9.5 8.3 11.3 9.2 13.2 10.0 14.1 10.2 15.0 10.5 16.2 10.5 16.5 9.6
29 9.5 8.3 11.3 9.2 13.2 10.0 14.1 10.2 15.0 10.5 16.1 10.4 16.3 9.5
31 9.5 8.3 11.3 9.2 13.2 10.0 14.1 10.2 15.0 10.5 15.8 10.2 16.0 9.4
33 9.5 8.3 11.3 9.2 13.2 10.0 14.1 10.2 15.0 10.5 15.5 10.0 15.8 9.2
35 9.5 8.3 11.3 9.2 13.2 10.0 14.1 10.2 15.0 10.5 15.2 9.9 15.5 9.1
37 9.5 8.3 11.3 9.2 13.2 10.0 14.1 10.2 14.7 10.2 14.9 9.7 15.3 8.9
39 9.5 8.3 11.3 9.2 13.2 10.0 14.1 10.2 14.4 10.0 14.7 9.5 15.1 8.8

Notes:
TC: Total Capacity(kW), SHC: Sensible Heat Capacity(kW) 2. Refer to Capacity Correction Factor in the outdoor unit PDB for
1. Capacity tables show the representative value of conditions the actual performance data of each indoor unit and outdoor unit
which may occur. combination.

Ceiling Cassette 4-way _ 17


6. Capacity Tables
6.2 Heating Capacity Heating capacity

Outdoor air Indoor air temp. (DB, °C)


Capacity temp. 16 18 20 21 22 24
Index TC TC TC TC TC TC
DB(°C) WB(°C)
kW kW kW kW kW kW
-24.8 -25.0 1.0 1.0 1.0 1.0 1.0 1.0
-21.8 -22.0 1.3 1.3 1.3 1.3 1.3 1.2
-19.8 -20.0 1.3 1.3 1.3 1.3 1.3 1.3
-18.8 -19.0 1.4 1.3 1.3 1.3 1.3 1.3
-16.7 -17.0 1.4 1.4 1.4 1.4 1.4 1.4
-14.7 -15.0 1.5 1.5 1.5 1.5 1.5 1.5
-12.6 -13.0 1.6 1.6 1.6 1.6 1.5 1.5
-10.5 -11.0 1.6 1.6 1.6 1.6 1.6 1.6
-9.5 -10.0 1.7 1.7 1.7 1.7 1.7 1.6
-8.5 -9.1 1.7 1.7 1.7 1.7 1.7 1.6
-7.0 -7.6 1.7 1.7 1.7 1.7 1.7 1.6
1.6 -5.0 -5.6 1.8 1.8 1.8 1.7 1.7 1.6
-3.0 -3.7 1.9 1.8 1.8 1.7 1.7 1.6
0.0 -0.7 1.9 1.9 1.8 1.7 1.7 1.6
3.0 2.2 2.0 1.9 1.8 1.7 1.7 1.6
Indoor Units

5.0 4.1 2.0 1.9 1.8 1.7 1.7 1.6


7.0 6.0 2.0 1.9 1.8 1.7 1.7 1.6
9.0 7.9 2.0 1.9 1.8 1.7 1.7 1.6
11.0 9.8 2.0 1.9 1.8 1.7 1.7 1.6
13.0 11.8 2.0 1.9 1.8 1.7 1.7 1.6
15.0 13.7 2.0 1.9 1.8 1.7 1.7 1.6
-24.8 -25.0 1.4 1.4 1.4 1.4 1.4 1.4
-21.8 -22.0 1.7 1.7 1.7 1.7 1.7 1.7
-19.8 -20.0 1.8 1.8 1.8 1.8 1.8 1.8
-18.8 -19.0 1.9 1.9 1.9 1.9 1.9 1.9
-16.7 -17.0 2.0 2.0 2.0 2.0 2.0 2.0
-14.7 -15.0 2.1 2.1 2.1 2.1 2.1 2.0
-12.6 -13.0 2.2 2.2 2.2 2.2 2.1 2.1
-10.5 -11.0 2.3 2.3 2.2 2.2 2.2 2.2
-9.5 -10.0 2.3 2.3 2.3 2.3 2.3 2.2
-8.5 -9.1 2.3 2.3 2.3 2.3 2.3 2.2
2.2 -7.0 -7.6 2.4 2.4 2.4 2.4 2.3 2.2
-5.0 -5.6 2.5 2.5 2.5 2.4 2.3 2.2
-3.0 -3.7 2.6 2.6 2.5 2.4 2.3 2.2
0.0 -0.7 2.7 2.6 2.5 2.4 2.3 2.2
3.0 2.2 2.7 2.7 2.5 2.4 2.3 2.2
5.0 4.1 2.8 2.7 2.5 2.4 2.3 2.2
7.0 6.0 2.8 2.7 2.5 2.4 2.3 2.2
9.0 7.9 2.8 2.7 2.5 2.4 2.3 2.2
11.0 9.8 2.8 2.7 2.5 2.4 2.3 2.2
13.0 11.8 2.8 2.7 2.5 2.4 2.3 2.2
15.0 13.7 2.8 2.7 2.5 2.4 2.3 2.2
-24.8 -25.0 1.9 1.9 1.8 1.8 1.8 1.8
-21.8 -22.0 2.2 2.2 2.2 2.2 2.2 2.2
-19.8 -20.0 2.4 2.4 2.3 2.3 2.3 2.3
-18.8 -19.0 2.4 2.4 2.4 2.4 2.4 2.4
-16.7 -17.0 2.5 2.5 2.5 2.5 2.5 2.5
-14.7 -15.0 2.7 2.7 2.6 2.6 2.6 2.6
-12.6 -13.0 2.8 2.8 2.8 2.8 2.7 2.7
-10.5 -11.0 2.9 2.9 2.9 2.9 2.9 2.8
-9.5 -10.0 3.0 3.0 2.9 2.9 2.9 2.8
-8.5 -9.1 3.0 3.0 3.0 3.0 3.0 2.8
-7.0 -7.6 3.1 3.1 3.1 3.1 3.0 2.8
2.8 -5.0 -5.6 3.2 3.2 3.2 3.1 3.0 2.8
-3.0 -3.7 3.4 3.3 3.2 3.1 3.0 2.8
0.0 -0.7 3.4 3.3 3.2 3.1 3.0 2.8
3.0 2.2 3.5 3.4 3.2 3.1 3.0 2.8
5.0 4.1 3.6 3.4 3.2 3.1 3.0 2.8
7.0 6.0 3.6 3.4 3.2 3.1 3.0 2.8
9.0 7.9 3.6 3.4 3.2 3.1 3.0 2.8
11.0 9.8 3.6 3.4 3.2 3.1 3.0 2.8
13.0 11.8 3.6 3.4 3.2 3.1 3.0 2.8
15.0 13.7 3.6 3.4 3.2 3.1 3.0 2.8

18 _ Ceiling Cassette 4-way


6. Capacity Tables
Heating capacity

Outdoor air Indoor air temp. (DB, °C)


Capacity temp. 16 18 20 21 22 24
Index TC TC TC TC TC TC
DB(°C) WB(°C)
kW kW kW kW kW kW
-24.8 -25.0 2.3 2.3 2.3 2.3 2.3 2.3
-21.8 -22.0 2.8 2.8 2.8 2.8 2.8 2.8
-19.8 -20.0 2.9 2.9 2.9 2.9 2.9 2.9
-18.8 -19.0 3.0 3.0 3.0 3.0 3.0 3.0
-16.7 -17.0 3.1 3.1 3.1 3.1 3.1 3.1
-14.7 -15.0 3.3 3.3 3.3 3.3 3.3 3.3
-12.6 -13.0 3.5 3.4 3.4 3.4 3.4 3.4
-10.5 -11.0 3.6 3.6 3.6 3.6 3.6 3.5
-9.5 -10.0 3.7 3.7 3.7 3.7 3.7 3.5
-8.5 -9.1 3.8 3.8 3.7 3.7 3.7 3.5
3.6 -7.0 -7.6 3.9 3.9 3.9 3.8 3.7 3.5
-5.0 -5.6 4.0 4.0 4.0 3.9 3.7 3.5
-3.0 -3.7 4.2 4.1 4.0 3.9 3.7 3.5
0.0 -0.7 4.3 4.1 4.0 3.9 3.7 3.5
3.0 2.2 4.4 4.3 4.0 3.9 3.7 3.5

Indoor Units
5.0 4.1 4.5 4.3 4.0 3.9 3.7 3.5
7.0 6.0 4.5 4.3 4.0 3.9 3.7 3.5
9.0 7.9 4.5 4.3 4.0 3.9 3.7 3.5
11.0 9.8 4.5 4.3 4.0 3.9 3.7 3.5
13.0 11.8 4.5 4.3 4.0 3.9 3.7 3.5
15.0 13.7 4.5 4.3 4.0 3.9 3.7 3.5
-24.8 -25.0 2.9 2.9 2.9 2.9 2.9 2.9
-21.8 -22.0 3.5 3.5 3.5 3.5 3.5 3.5
-19.8 -20.0 3.7 3.7 3.7 3.7 3.7 3.6
-18.8 -19.0 3.8 3.7 3.7 3.7 3.7 3.7
-16.7 -17.0 3.9 3.9 3.9 3.9 3.9 3.9
-14.7 -15.0 4.1 4.1 4.1 4.1 4.1 4.1
-12.6 -13.0 4.3 4.3 4.3 4.3 4.3 4.3
-10.5 -11.0 4.5 4.5 4.5 4.5 4.5 4.4
-9.5 -10.0 4.6 4.6 4.6 4.6 4.6 4.4
-8.5 -9.1 4.7 4.7 4.7 4.7 4.7 4.4
4.5 -7.0
-5.0
-7.6
-5.6
4.8
5.0
4.8
5.0
4.8
5.0
4.8
4.8
4.7
4.7
4.4
4.4
-3.0 -3.7 5.3 5.1 5.0 4.8 4.7 4.4
0.0 -0.7 5.3 5.2 5.0 4.8 4.7 4.4
3.0 2.2 5.5 5.3 5.0 4.8 4.7 4.4
5.0 4.1 5.6 5.3 5.0 4.8 4.7 4.4
7.0 6.0 5.6 5.3 5.0 4.8 4.7 4.4
9.0 7.9 5.6 5.3 5.0 4.8 4.7 4.4
11.0 9.8 5.6 5.3 5.0 4.8 4.7 4.4
13.0 11.8 5.6 5.3 5.0 4.8 4.7 4.4
15.0 13.7 5.6 5.3 5.0 4.8 4.7 4.4
-24.8 -25.0 3.6 3.6 3.6 3.6 3.6 3.6
-21.8 -22.0 4.4 4.4 4.4 4.4 4.4 4.4
-19.8 -20.0 4.6 4.6 4.6 4.6 4.6 4.6
-18.8 -19.0 4.8 4.7 4.7 4.7 4.7 4.7
-16.7 -17.0 5.0 5.0 5.0 4.9 4.9 4.9
-14.7 -15.0 5.2 5.2 5.2 5.2 5.2 5.2
-12.6 -13.0 5.5 5.4 5.4 5.4 5.4 5.4
-10.5 -11.0 5.7 5.7 5.7 5.7 5.7 5.5
-9.5 -10.0 5.8 5.8 5.8 5.8 5.8 5.5
-8.5 -9.1 5.9 5.9 5.9 5.9 5.9 5.5
5.6 -7.0 -7.6 6.1 6.1 6.1 6.0 5.9 5.5
-5.0 -5.6 6.3 6.3 6.3 6.1 5.9 5.5
-3.0 -3.7 6.6 6.5 6.3 6.1 5.9 5.5
0.0 -0.7 6.7 6.5 6.3 6.1 5.9 5.5
3.0 2.2 6.9 6.7 6.3 6.1 5.9 5.5
5.0 4.1 7.0 6.7 6.3 6.1 5.9 5.5
7.0 6.0 7.1 6.7 6.3 6.1 5.9 5.5
9.0 7.9 7.1 6.7 6.3 6.1 5.9 5.5
11.0 9.8 7.1 6.7 6.3 6.1 5.9 5.5
13.0 11.8 7.1 6.7 6.3 6.1 5.9 5.5
15.0 13.7 7.1 6.7 6.3 6.1 5.9 5.5

Ceiling Cassette 4-way _ 19


6. Capacity Tables
Heating capacity

Outdoor air Indoor air temp. (DB, °C)


Capacity temp. 16 18 20 21 22 24
Index TC TC TC TC TC TC
DB(°C) WB(°C)
kW kW kW kW kW kW
-24.8 -25.0 4.6 4.6 4.6 4.6 4.6 4.6
-21.8 -22.0 5.6 5.6 5.6 5.6 5.6 5.5
-19.8 -20.0 5.9 5.9 5.9 5.9 5.9 5.8
-18.8 -19.0 6.0 6.0 6.0 6.0 6.0 6.0
-16.7 -17.0 6.3 6.3 6.3 6.3 6.3 6.3
-14.7 -15.0 6.6 6.6 6.6 6.6 6.6 6.6
-12.6 -13.0 6.9 6.9 6.9 6.9 6.9 6.9
-10.5 -11.0 7.2 7.2 7.2 7.2 7.2 7.0
-9.5 -10.0 7.4 7.4 7.3 7.3 7.3 7.0
-8.5 -9.1 7.5 7.5 7.5 7.5 7.5 7.0
7.1 -7.0 -7.6 7.7 7.7 7.7 7.7 7.5 7.0
-5.0 -5.6 8.0 8.0 8.0 7.7 7.5 7.0
-3.0 -3.7 8.4 8.2 8.0 7.7 7.5 7.0
0.0 -0.7 8.6 8.3 8.0 7.7 7.5 7.0
3.0 2.2 8.8 8.5 8.0 7.7 7.5 7.0
Indoor Units

5.0 4.1 8.9 8.5 8.0 7.7 7.5 7.0


7.0 6.0 9.0 8.5 8.0 7.7 7.5 7.0
9.0 7.9 9.0 8.5 8.0 7.7 7.5 7.0
11.0 9.8 9.0 8.5 8.0 7.7 7.5 7.0
13.0 11.8 9.0 8.5 8.0 7.7 7.5 7.0
15.0 13.7 9.0 8.5 8.0 7.7 7.5 7.0
-24.8 -25.0 5.3 5.3 5.3 5.3 5.3 5.3
-21.8 -22.0 6.4 6.4 6.4 6.4 6.4 6.4
-19.8 -20.0 6.8 6.8 6.7 6.7 6.7 6.7
-18.8 -19.0 6.9 6.9 6.9 6.9 6.9 6.9
-16.7 -17.0 7.2 6.9 7.2 7.2 7.2 7.2
-14.7 -15.0 7.6 6.9 7.6 7.6 7.6 7.5
-12.6 -13.0 8.0 6.9 7.9 7.9 7.9 7.9
-10.5 -11.0 8.3 6.9 8.3 8.3 8.3 8.0
-9.5 -10.0 8.5 6.9 8.4 8.4 8.4 8.0
-8.5 -9.1 8.6 6.9 8.6 8.6 8.6 8.0
8.2 -7.0 -7.6 8.9 6.9 8.9 8.8 8.6 8.0
-5.0 -5.6 9.2 6.9 9.2 8.9 8.6 8.0
-3.0 -3.7 9.7 6.9 9.2 8.9 8.6 8.0
0.0 -0.7 9.8 6.9 9.2 8.9 8.6 8.0
3.0 2.2 10.1 6.9 9.2 8.9 8.6 8.0
5.0 4.1 10.3 6.9 9.2 8.9 8.6 8.0
7.0 6.0 10.4 6.9 9.2 8.9 8.6 8.0
9.0 7.9 10.4 6.9 9.2 8.9 8.6 8.0
11.0 9.8 10.4 6.9 9.2 8.9 8.6 8.0
13.0 11.8 10.4 6.9 9.2 8.9 8.6 8.0
15.0 13.7 10.4 6.9 9.2 8.9 8.6 8.0
-24.8 -25.0 6.9 6.9 6.8 6.8 6.8 6.8
-21.8 -22.0 8.3 8.3 8.3 8.3 8.3 8.2
-19.8 -20.0 8.8 8.8 8.7 8.7 8.7 8.6
-18.8 -19.0 9.0 8.9 8.9 8.9 8.9 8.9
-16.7 -17.0 9.4 9.4 9.4 9.3 9.3 9.3
-14.7 -15.0 9.9 9.9 9.8 9.8 9.8 9.8
-12.6 -13.0 10.3 10.3 10.3 10.3 10.2 10.2
-10.5 -11.0 10.8 10.8 10.7 10.7 10.7 10.4
-9.5 -10.0 11.0 11.0 10.9 10.9 10.9 10.4
-8.5 -9.1 11.2 11.2 11.1 11.1 11.1 10.4
-7.0 -7.6 11.5 11.5 11.5 11.4 11.1 10.4
10.6 -5.0 -5.6 12.0 11.9 11.9 11.5 11.1 10.4
-3.0 -3.7 12.5 12.2 11.9 11.5 11.1 10.4
0.0 -0.7 12.7 12.3 11.9 11.5 11.1 10.4
3.0 2.2 13.1 12.7 11.9 11.5 11.1 10.4
5.0 4.1 13.3 12.7 11.9 11.5 11.1 10.4
7.0 6.0 13.4 12.7 11.9 11.5 11.1 10.4
9.0 7.9 13.4 12.7 11.9 11.5 11.1 10.4
11.0 9.8 13.4 12.7 11.9 11.5 11.1 10.4
13.0 11.8 13.4 12.7 11.9 11.5 11.1 10.4
15.0 13.7 13.4 12.7 11.9 11.5 11.1 10.4

20 _ Ceiling Cassette 4-way


6. Capacity Tables
Heating capacity

Outdoor air Indoor air temp. (DB, °C)


Capacity temp. 16 18 20 21 22 24
Index TC TC TC TC TC TC
DB(°C) WB(°C)
kW kW kW kW kW kW
-24.8 -25.0 8.0 8.0 7.9 7.9 7.9 7.9
-21.8 -22.0 9.7 9.7 9.6 9.6 9.6 9.5
-19.8 -20.0 10.2 10.2 10.1 10.1 10.1 10.0
-18.8 -19.0 10.4 10.3 10.3 10.3 10.3 10.3
-16.7 -17.0 10.9 10.9 10.9 10.8 10.8 10.8
-14.7 -15.0 11.4 11.4 11.4 11.4 11.4 11.3
-12.6 -13.0 12.0 11.9 11.9 11.9 11.8 11.8
-10.5 -11.0 12.5 12.5 12.4 12.4 12.4 12.0
-9.5 -10.0 12.7 12.7 12.7 12.7 12.7 12.0
-8.5 -9.1 13.0 13.0 12.9 12.9 12.9 12.0
-7.0 -7.6 13.3 13.3 13.3 13.2 12.9 12.0
12.3 -5.0 -5.6 13.9 13.8 13.8 13.4 12.9 12.0
-3.0 -3.7 14.5 14.2 13.8 13.4 12.9 12.0
0.0 -0.7 14.8 14.3 13.8 13.4 12.9 12.0

Indoor Units
3.0 2.2 15.2 14.7 13.8 13.4 12.9 12.0
5.0 4.1 15.4 14.7 13.8 13.4 12.9 12.0
7.0 6.0 15.6 14.7 13.8 13.4 12.9 12.0
9.0 7.9 15.6 14.7 13.8 13.4 12.9 12.0
11.0 9.8 15.6 14.7 13.8 13.4 12.9 12.0
13.0 11.8 15.6 14.7 13.8 13.4 12.9 12.0
15.0 13.7 15.6 14.7 13.8 13.4 12.9 12.0
-24.8 -25.0 9.2 9.2 9.1 9.1 9.1 9.1
-21.8 -22.0 11.1 11.1 11.1 11.1 11.1 11.0
-19.8 -20.0 11.7 11.7 11.6 11.6 11.6 11.6
-18.8 -19.0 12.0 11.9 11.9 11.9 11.9 11.9
-16.7 -17.0 12.5 12.5 12.5 12.4 12.4 12.4
-14.7 -15.0 13.2 13.2 13.1 13.1 13.1 13.0
-12.6 -13.0 13.8 13.7 13.7 13.7 13.6 13.6
-10.5 -11.0 14.4 14.4 14.3 14.3 14.3 13.9
-9.5 -10.0 14.7 14.7 14.6 14.6 14.6 13.9
-8.5 -9.1 14.9 14.9 14.9 14.9 14.9 13.9
14.1 -7.0 -7.6 15.4 15.3 15.3 15.2 14.9 13.9
-5.0 -5.6 16.0 15.9 15.9 15.4 14.9 13.9
-3.0 -3.7 16.7 16.3 15.9 15.4 14.9 13.9
0.0 -0.7 17.0 16.5 15.9 15.4 14.9 13.9
3.0 2.2 17.5 16.9 15.9 15.4 14.9 13.9
5.0 4.1 17.7 16.9 15.9 15.4 14.9 13.9
7.0 6.0 17.9 16.9 15.9 15.4 14.9 13.9
9.0 7.9 17.9 16.9 15.9 15.4 14.9 13.9
11.0 9.8 17.9 16.9 15.9 15.4 14.9 13.9
13.0 11.8 17.9 16.9 15.9 15.4 14.9 13.9
15.0 13.7 17.9 16.9 15.9 15.4 14.9 13.9

Notes:
TC: Total Capacity(kW) 3. In accordance with operation limits of outdoor unit, applicable range of
1. Capacity tables show the representative value of conditions which may occur. capacity tables is different.
2. is shown as reference. When selecting the outdoor units, avoid the 4. Refer to Capacity Correction Factor in the outdoor unit PDB for the actual
outdoor air temperature range shown by . performance data of each indoor unit and outdoor unit combination.

Ceiling Cassette 4-way _ 21


7. Air Velocity and Temperature Distribution(Reference Data)
ARNU05GTR*2, ARNU07GTR*2, ARNU09GTR*2
Cooling Heating
Discharge angle: 40° Discharge angle: 50°

Air velocity [m/s] Air velocity [m/s]

2.7m 2.7m
2.0 2.0 2.0 2.0

1.5 1.5 2m 1.5 2m


1.5
1.0 1.0
1.0 1.0
0.5 0.5
1m 1m
0.5 0.5

0m 0m
2.5m 1.5m 0m 1.5m 2.5m 2.5m 1.5m 0m 1.5m 2.5m

Temperature [°C] Temperature [°C]

2.7m 2.7m
Indoor Units

33 33
2m 21 21 2m
18 18
20 20 27 27
18 18
24 24 1m
22 1m
22

24 24
0m 0m
2.5m 1.5m 0m 1.5m 2.5m 2.5m 1.5m 0m 1.5m 2.5m

ARNU12GTR*2
Cooling Heating
Discharge angle: 40° Discharge angle: 50°

Air velocity [m/s] Air velocity [m/s]

2.7m 2.7m
2.0 2.0
2.0 2.0
1.5 1.5
2m 2m
1.5 1.5
1.0 1.0
1.0 1.0
1m 0.5 0.5 1m

0.5 0.5

0m 0m
2.5m 1.5m 0m 1.5m 2.5m 2.5m 1.5m 0m 1.5m 2.5m

Temperature [°C] Temperature [°C]

2.7m 2.7m
18 18 33 33
2m 30 30 2m
20 20
27 27
24 24
22 22 21 21
1m 1m

24 24
0m 0m
2.5m 1.5m 0m 1.5m 2.5m 2.5m 1.5m 0m 1.5m 2.5m

22 _ Ceiling Cassette 4-way


7. Air Velocity and Temperature Distribution(Reference Data)
ARNU15GTQ*2
Cooling Heating
Discharge angle: 40° Discharge angle: 50°

Air velocity [m/s] Air velocity [m/s]

2.7m 2.7m
2.0 2.0
2.0 2.0 2m 2m
1.5 1.5 1.5
1.5
1.0 1m 1m
1.0 1.0 1.0
0.5 0.5 0.5 0.5
0m 0m
4m 3m 2m 1m 0m 1m 2m 3m 4m 4m 3m 2m 1m 0m 1m 2m 3m 4m

Temperature [°C] Temperature [°C]

2.7m 2.7m

Indoor Units
18 18 33 33
20 20 2m 2m

22 22 24
21 24 21
1m 1m
27 27
24 24
0m 0m
4m 3m 2m 1m 0m 1m 2m 3m 4m 4m 3m 2m 1m 0m 1m 2m 3m 4m

ARNU18GTQ*2
Cooling Heating
Discharge angle: 40° Discharge angle: 50°

Air velocity [m/s] Air velocity [m/s]

2.7m 2.7m
2.0 2.0 2.0 2.0
2m 2m
1.5 1.5
1.5 1.5

1m 1.0 1.0 1m
1.0 1.0
0.5 0.5 0.5 0.5
0m 0m
4m 3m 2m 1m 0m 1m 2m 3m 4m 4m 3m 2m 1m 0m 1m 2m 3m 4m

Temperature [°C] Temperature [°C]

2.7m 2.7m
18 18 33 33
20 20 2m 2m
30 30
22 22 21 21
1m 27 27 1m
24 24

24 24
0m 0m
4m 3m 2m 1m 0m 1m 2m 3m 4m 4m 3m 2m 1m 0m 1m 2m 3m 4m

Ceiling Cassette 4-way _ 23


7. Air Velocity and Temperature Distribution(Reference Data)
ARNU24GTP*2
Cooling Heating
Discharge angle: 40° Discharge angle: 50°

Air velocity [m/s] Air velocity [m/s]

2.7m 2.7m
2.0 2.0
2m 2m

2.0 2.0
1m 1m
1.5 1.5 1.0 1.0

1.0 1.0 0.5 0.5


0m 0m
4m 3m 2m 1m 0m 1m 2m 3m 4m 4m 3m 2m 1m 0m 1m 2m 3m 4m

Temperature [°C] Temperature [°C]

2.7m 2.7m
Indoor Units

18 18 33 33
20 20 30 30 2m
2m
22 22

22
1m 22 1m
24 24
23 23 27 27
24 24
0m 0m
4m 3m 2m 1m 0m 1m 2m 3m 4m 4m 3m 2m 1m 0m 1m 2m 3m 4m

ARNU28GTP*2
Cooling Heating
Discharge angle: 40° Discharge angle: 50°

Air velocity [m/s] Air velocity [m/s]

2.7m 2.7m
2.5 2.5 3.0 3.0
2.0 2.0
2.0 2m 2m
2.0 1.5
1.5

1.0 1.0
1m 1m
1.5 1.5
1.0 1.0 0.5 0.5
0m 0m
4m 3m 2m 1m 0m 1m 2m 3m 4m 4m 3m 2m 1m 0m 1m 2m 3m 4m

Temperature [°C] Temperature [°C]

2.7m 2.7m
18 18 33 33
2m 2m

21 30 30 24 21
22 24
22 1m 1m

23 23 27 27
0m 0m
4m 3m 2m 1m 0m 1m 2m 3m 4m 4m 3m 2m 1m 0m 1m 2m 3m 4m

24 _ Ceiling Cassette 4-way


7. Air Velocity and Temperature Distribution(Reference Data)
ARNU36GTN*2
Cooling Heating
Discharge angle: 40° Discharge angle: 50°

Air velocity [m/s] Air velocity [m/s]

2.7m 2.7m
3.0 3.0 3.5 3.5
2.5 2.5 3.0 3.0
2.0 2m 2m
2.0 2.5 2.5

1.5 1.5 1m 1m
2.0 2.0

1.0 1.0 1.0 1.0


0m 0m
5m 4m 3m 2m 1m 0m 1m 2m 3m 4m 5m 5m 4m 3m 2m 1m 0m 1m 2m 3m 4m 5m

Temperature [°C] Temperature [°C]

2.7m 2.7m

Indoor Units
18 18 33 33

20 2m 2m
20
30 30 24
24
22 22 1m 22 22 1m

23 23 27 27
0m 0m
5m 4m 3m 2m 1m 0m 1m 2m 3m 4m 5m 5m 4m 3m 2m 1m 0m 1m 2m 3m 4m 5m

ARNU42GTM*2
Cooling Heating
Discharge angle: 40° Discharge angle: 50°

Air velocity [m/s] Air velocity [m/s]

3.2m 3.2m
4.0 4.0 4.0
4.0

3.0 2m 3.0 3.0 2m


3.0

1m 1m
2.0 2.0 2.0 2.0
1.0 1.0 1.0 1.0
0m 0m
5m 4m 3m 2m 1m 0m 1m 2m 3m 4m 5m 5m 4m 3m 2m 1m 0m 1m 2m 3m 4m 5m

Temperature [°C] Temperature [°C]

3.2m 3.2m
18 18 33 33

2m 2m
20 20 24 24
30 30
1m 22 22 1m

22 22 27 27
24 24
0m 0m
5m 4m 3m 2m 1m 0m 1m 2m 3m 4m 5m 5m 4m 3m 2m 1m 0m 1m 2m 3m 4m 5m

Ceiling Cassette 4-way _ 25


7. Air Velocity and Temperature Distribution(Reference Data)
ARNU48GTM*2
Cooling Heating
Discharge angle: 40° Discharge angle: 50°

Air velocity [m/s] Air velocity [m/s]

3.2m 3.2m
4.0 4.0
4.0 4.0

2m 2m
3.0 3.0 3.0 3.0

1m 1m
2.0 2.0
2.0 2.0
1.0 1.0
1.0 1.0
0m 0m
5m 4m 3m 2m 1m 0m 1m 2m 3m 4m 5m 5m 4m 3m 2m 1m 0m 1m 2m 3m 4m 5m

Temperature [°C] Temperature [°C]


Indoor Units

3.2m 3.2m
18 18 33 33

20 2m 2m
20
22 22
24 24
1m 1m
30 30
22 22
27 27
24 24
0m 0m
5m 4m 3m 2m 1m 0m 1m 2m 3m 4m 5m 5m 4m 3m 2m 1m 0m 1m 2m 3m 4m 5m

26 _ Ceiling Cassette 4-way


8. Electric Characteristicss
Units Power Supply IFM Input(W)
Model Type Hz Volts Voltage Range MCA MFA kW FLA Cooling Heating
ARNU05GTR*2 TR 0.25 15 0.043 0.2 30 30
ARNU07GTR*2 TR 0.25 15 0.043 0.2 30 30
ARNU09GTR*2 TR 0.25 15 0.043 0.2 30 30
ARNU12GTR*2 TR 0.25 15 0.043 0.2 30 30
ARNU15GTQ*2 TQ 0.25 15 0.043 0.2 30 30
MAX : 264
ARNU18GTQ*2 TQ 50 220-240 0.25 15 0.043 0.2 30 30
MIN:198
ARNU24GTP*2 TP 0.22 15 0.03 0.17 33 33
ARNU28GTP*2 TP 0.22 15 0.03 0.17 33 33
ARNU36GTN*2 TN 0.81 15 0.135 0.64 144 144
ARNU42GTM*2 TM 0.81 15 0.135 0.64 144 144
ARNU48GTM*2 TM 0.81 15 0.135 0.64 144 144
ARNU05GTR*2 TR 0.25 15 0.043 0.2 30 30

Indoor Units
ARNU07GTR*2 TR 0.25 15 0.043 0.2 30 30
ARNU09GTR*2 TR 0.25 15 0.043 0.2 30 30
ARNU12GTR*2 TR 0.25 15 0.043 0.2 30 30
ARNU15GTQ*2 TQ 0.25 15 0.043 0.2 30 30
MAX : 242
ARNU18GTQ*2 TQ 60 220 0.25 15 0.043 0.2 30 30
MIN:198
ARNU24GTP*2 TP 0.22 15 0.03 0.17 33 33
ARNU28GTP*2 TP 0.22 15 0.03 0.17 33 33
ARNU36GTN*2 TN 0.81 15 0.135 0.64 144 144
ARNU42GTM*2 TM 0.81 15 0.135 0.64 144 144
ARNU48GTM*2 TM 0.81 15 0.135 0.64 144 144

Symbols:
MCA : Minimum Circuit Amperes (A)
MFA : Maximum Fuse Amperes(see note 5)
kW : Fan Motor Rated Output(kW)
FLA : Full Load Amperes(A)
IFM : Indoor Fan Motor

Note :
1. Voltage Range
Units are suitable for use on electrical system where voltage supplied to unit terminals is not below or above the
listed range limits.
2. Maximum allowable voltage unbalance between phase is 2%.
3. MCA/MFA
MCA = 1.25 x FLA
MFA ≤ 4 x FLA
( Next lower standard fuse rating. Minimum 15A)
4. Select wire size based on the larger value on the MCA.
5. Instead of fuse, use Circuit Breaker.

Ceiling Cassette 4-way _ 27


9. Sound Levels
Overall
Notes:
1. Sound measured at 1.5m away from the center of the unit
2. Operating condition
- Power source : 220-240V 50Hz / 220V 60Hz
- Cooling : Indoor temperature (27°C DB, 19°C WB),
Outdoor temperature (35°C DB, 24°C WB)
Ceiling - Heating : Indoor temperature (20°C DB, 15°C WB),
Outdoor temperature (7°C DB, 6°C WB)
1.5m
3. Reference accoustic pressure 0dB = 20μPa
4. Sound level will vary depending on a range of factors such as
the construction(acoustic absorption coefficient) of particular
room in which the equipment in installed.
❈ Measuring place : Anechoic chamber

Model Sound Level dB(A) Model Sound Level dB(A)


H M L H M L
ARNU05GTR*2 29 27 26 ARNU24GTP*2 36 34 31
ARNU07GTR*2 29 27 26 ARNU28GTP*2 39 35 33
Indoor Units

ARNU09GTR*2 30 29 27 ARNU36GTN*2 43 40 37
ARNU12GTR*2 32 30 27 ARNU42GTM*2 44 41 38
ARNU15GTQ*2 36 34 32 ARNU48GTM*2 46 43 41
ARNU18GTQ*2 37 35 34

Sound Pressure Level


ARNU05GTR*2 ARNU07GTR*2 ARNU09GTR*2
80 80 80

70 70 70
Octave Band Sound Pressure Level (0dB = 20μPa)

Octave Band Sound Pressure Level (0dB = 20μPa)

Octave Band Sound Pressure Level (0dB = 20μPa)

NC-65 NC-65 NC-65


60 60 60

NC-60 NC-60 NC-60

NC-55 NC-55 NC-55


50 50 50

NC-50 NC-50 NC-50

NC-45 NC-45 NC-45


40 40 40

NC-40 NC-40 NC-40

NC-35 NC-35 30 NC-35


30 30

NC-30 NC-30 NC-30

20 NC-25 20 NC-25 20 NC-25

Approximate Approximate Approximate


NC-20 NC-20 NC-20
Hearing Hearing Hearing
Threshold NC-15 Threshold NC-15 Threshold NC-15
10 10 10
63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

28 _ Ceiling Cassette 4-way


9. Sound Levels
80
ARNU12GTR*2 ARNU15GTQ*2 ARNU18GTQ*2
80 80

Octave Band Sound Pressure Level (0dB = 20μPa)


70 70 70
Octave Band Sound Pressure Level (0dB = 20μPa)

Octave Band Sound Pressure Level (0dB = 20μPa)


NC-65 NC-65 NC-65
60 60 60
NC-60 NC-60 NC-60

NC-55 NC-55 NC-55


50 50 50
NC-50 NC-50 NC-50

NC-45 NC-45 NC-45


40 40 40
NC-40 NC-40 NC-40

NC-35 NC-35 NC-35


30 30 30
NC-30 NC-30 NC-30

20 NC-25 20 NC-25 20 NC-25


Approximate Approximate Approximate
NC-20 NC-20 NC-20
Hearing Hearing Hearing
Threshold Threshold NC-15 Threshold
10 NC-15 10 10 NC-15
63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

ARNU24GTP*2 ARNU28GTP*2

Indoor Units
ARNU36GTN*2
80 80 80
Octave Band Sound Pressure Level (0dB = 20μPa)

Octave Band Sound Pressure Level (0dB = 20μPa)

Octave Band Sound Pressure Level (0dB = 20μPa)


70 70 70

NC-65 NC-65 NC-65


60 60 60

NC-60 NC-60 NC-60

NC-55 NC-55 NC-55


50 50 50

NC-50 NC-50
NC-50

NC-45 NC-45 NC-45


40 40
40
NC-40 NC-40
NC-40

NC-35 NC-35 30 NC-35


30 30

NC-30 NC-30
NC-30

20 NC-25 20 NC-25
20 NC-25
Approximate Approximate Approximate
NC-20 NC-20
NC-20 Hearing Hearing
Hearing
Threshold Threshold NC-15
Threshold NC-15 NC-15 10
10 10
63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000
63 125 250 500 1000 2000 4000 8000
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

ARNU42GTM*2 ARNU48GTM*2
80 80
Octave Band Sound Pressure Level (0dB = 20μPa)

Octave Band Sound Pressure Level (0dB = 20μPa)

70 70

NC-65 NC-65
60 60
NC-60 NC-60

NC-55 NC-55
50 50
NC-50 NC-50
NC-45 NC-45
40 40
NC-40 NC-40

NC-35 NC-35
30 30
NC-30 NC-30

20 NC-25 20 NC-25
Approximate Approximate
NC-20 NC-20
Hearing Hearing
Threshold NC-15 Threshold
10 10 NC-15
63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

Ceiling Cassette 4-way _ 29


10. Installation
• Please read this instruction sheet completely before installing the product.
• When the power cord is damaged, replacement work shall be performed by authorized personnel only.
• Installation work must be performed in accordance with the national wiring standards by authorized personnel only.

Anti-bacteria filter
Indoor Units

Air
Intake Remote
Controll
er
TEM
P

Air Outlet
Wired Remote Controller(Optional)

Required Parts Required Tools


• Connecting cable • Level
• Pipes: Gas side • Screw driver
Liquid side • Electric drill
• Hanging Bolt • Hole core drill
(W 3/8 or M10 length 650mm) • Flaring Tool set
• Insulated drain hose • Torque Wrenches
• Additional Drain hose • Hexagonal Wrench
• Gas-leak detector
• Thermometer

10.1 Selection of the best location


• If the temperature might rise above 30℃ or the humidity might rise above RH 80%, attach the Dew-Protective kit
or use another insulation to the indoor body.
h Dew Protective kit is sold separately.
Use glass wool material or polyethylene foam and make sure at least 10mm thick.
• There should not be any heat source or steam near the unit.
• There should not be any obstacles to the air circulation.
• A place where air circulation in the room will be good.
• A place where drainage can be easily obtained.
• A place where noise prevention is taken into consideration.
• Do not install the unit near the door way.
• Ensure the spaces indicated by arrows from the wall, ceiling, or other obstacles.
• The indoor unit must have sufficient maintenance space.

30 _ Ceiling Cassette 4-way


10. Installation
n TQ/TR Chassis

10(13/32)
or more
Ceiling Ceiling Board
Ceiling Board

300(11-13/16) or less
3600(141-23/32) or less
1000(39-3/8)
500(19-11/16)

At least 1800(70-7/8)
or more
30(1-3/16) 500(19-11/16) or more
or more
±3(1/8)

Unit:mm(inch)

Floor

Indoor Units
n TP Chassis

10(13/32)
or more
Ceiling Ceiling Board
Ceiling Board

300(11-13/16) or less
1000(39-3/8)

3600(141-23/32) or less

500(19-11/16)
At least 1800(70-7/8)
or more

15(19/32) 500(19-11/16) or more


or more
±3(1/8)

Unit:mm(inch)

Floor

n TM/TN Chassis

10(13/32)
or more
Ceiling Ceiling Board
Ceiling Board
300(11-13/16) or less
4200(165-11/32) or less
1000(39-3/8)

500(19-11/16)
At least 1800(70-7/8)
or more

15(19/32) 500(19-11/16) or more


or more
±3(1/8)

Unit:mm(inch)

Floor

Ceiling Cassette 4-way _ 31


10. Installation
10.2 Ceiling opening dimensions and hanging bolt location
• The dimensions of the paper pattern for installation are the same as those of the ceiling opening dimensions.

Ceiling
Ceiling board

Level gauge

TQ/TR Chassis TM/TN/TP Chassis


585~660(Ceiling opening)
875(Ceiling opening)
517 787(Hanging bolt)
585~660(Ceiling opening)
Indoor Units

570

875(Ceiling opening)
684(Hanging bolt)
523

517

570
319

840 Unit size


671

840 Unit size


461
Unit:mm Unit:mm

CAUTION • Select and mark the position for fixing bolts and pip-
ing hole.
• This air-conditioner uses a drain pump.
• Decide the position for fixing bolts slightly tilted to
• Install the unit horizontally using a level gauge.
the drain direction after considering the direction of
• During the installation, care should be taken not to
drain hose.
damage electric wires.
• Drill the hole for anchor bolt on the wall.

32 _ Ceiling Cassette 4-way


10. Installation
NOTE:
• Avoid the following installation location.
1. Such places as restaurants and kitchen where considerable amount of oil steam and flour is generated.
These may cause heat exchange efficiency reduction, or water drops, drain pump mal-function.
In these cases, take the following actions;
• Make sure that ventilation fan is enough to cover all noxious gases from this place.
• Ensure enough distance from the cooking room to install the air conditioner in such a place where it may not suck oily steam.

Air conditioner

Take enough
distance
Use the ventilation fan
for smoke-collecting
hood with sufficient
capacity.
Cooking table

2. Avoid installng air conditioner in such places where cooking oil or iron powder is generated.

Indoor Units
3. Avoid places where inflammable gas is generated.
4. Avoid place where noxious gas is generated.
5. Avoid places near high frequency generators.

Ceiling

Hanging bolt Keep the length of the bolt

150mm
(W3/8 or M10) from the bracket to 40mm
Nut
Flat washer for M10 Air Conditioner body
(W3/8 or M10)
(accessory) Ceiling board Ceiling board

Keep the length of 15~18mm


between the air conditioner bottom
surface and the ceiling surface
Flat washer for M10
(accessory) Set screw of
Nut paper model (4 pieces)
(W3/8 or M10) Open the ceiling board
Paper model
for installation along the outer edge of the
paper model

• The following parts are locally purchased. CAUTION


① Hanging Bolt - W 3/8 or M10
② Nut - W 3/8 or M10 • Tighten the nut and bolt to prevent the unit
③ Spring Washer - M10 from falling.
④ Plate Washer - M10

Ceiling Cassette 4-way _ 33


10. Installation
10.3 Wiring Connection
Connect the wires to the terminals on the control board individually according to the outdoor unit connection.
• Ensure that the color of the wires of outdoor unit and the terminal No. are the same as those of indoor unit
respectively.

Indoor cord
Remote
control cord

power cord

• TR/TQ Chassis
[Indoor Unit side] [Outdoor Unit side]

[Type 1]

Terminal Block Indoor SODU B SODU A IDU B IDU A INT B INT A


1(L) 2(N) 3 4
Indoor Units

INDOOR POWER INPUT

[Type 2]
Terminal Block Indoor SODU IDU INTERNET DRY1 DRY2 GND 12V
1(L) 2(N) 3 4 B A - - B A - - - -

INDOOR POWER INPUT


[Type 3]
Terminal block of outdoor unit
Terminal Block Indoor Central controller Indoor unit Outdoor unit
1(L) 2(N) 3 4 12V GND DRY2 DRY1 CEN CEN IDU IDU SODU SODU

INDOOR POWER INPUT

• TM/TN/TP Chassis
[Indoor Unit side] [Outdoor Unit side]
[Type 1]

Terminal Block Indoor Terminal Block Indoor SODU B SODU A IDU B IDU A INT B INT A
1(L) 2(N) 3(L) 4(N) 5(A) 5(B) RD YL BK

POWER TO AIR
INPUT FRESH KIT
[Type 2]
Terminal Block Indoor Terminal Block Indoor SODU IDU INTERNET DRY1 DRY2 GND 12V
1(L) 2(N) 3(L) 4(N) 5(A) 5(B) RD YL BK B A B A B A - - - -

POWER TO AIR
INPUT FRESH KIT [Type 3]
Terminal block of outdoor unit
Terminal Block Indoor Terminal Block Indoor Central controller Indoor unit Outdoor unit
1(L) 2(N) 3(L) 4(N) 5(A) 5(B) RD YL BK 12V GND DRY2 DRY1 CEN CEN IDU IDU SODU SODU

POWER TO AIR
INPUT FRESH KIT

WARNING
Make sure that the screws of the terminal are not loose.

34 _ Ceiling Cassette 4-way


10. Installation
10.4 Installation of Decoration Panel
The decoration panel has its installation Before installing the decoration panel,
direction. always remove the paper template.

1. Temporarily fix two decoration panel fixing screws (hexagon M5 screw) on the unit body. (Tighten by
amount 10mm in length.)
The fixing screws (hexagon M5 screw) are included in the indoor unit box.
2. Remove the air inlet grille from the decoration panel. (Remove the hook for the air inlet grille cord.)
3. Hook the decoration panel key hole ( ) on the screws fixed in step above, and slide the panel so
that the screws reach the key hole edge.
4. Retighten completely two temporarily fixed screws and other two screws. (Total 4 screws)
5. Connect the louver motor connector and display connector.
6. After tightening these screws, install the air inlet grille (including the air filter).
Piping side

Air conditioner unit

Indoor Units
Control box cover
Decoration panel fixing screws
(hexagon M5 screws)
Temporally fitting at 2 places
(Tightening about 10mm) Louver motor

Decoration panel

Display
Lead wire for
louver motor and
display

Decoration panel fixing screws


(Hexagon M5 screw)

CAUTION
Inlet Grille
Install certainly the decoration
Good example Bad example
panel. Air conditioner unit
Cool air leakage causes Air conditioner Air Cool air leakage
sweating. unit
(no good)
⇨ Water drops fall.
Ceiling Ceiling
board board
Decoration panel Decoration
Fit the insulator (this part) and panel
be careful for cool air leakage

Ceiling Cassette 4-way _ 35


10. Installation
10.5 Indoor Unit Drain Piping Upward
Pipe clamp
• Drain piping must have down-slope (1/50 to 1/100): be sure not to pro- routing
not allowed
vide up-and-down slope to prevent reversal flow.
• During drain piping connection, be careful not to exert extra force on the Indoor unit
drain port on the indoor unit.
• The outside diameter of the drain connection on the indoor unit is 32mm.
Maintenance
Piping material: Polyvinyl chloride pipe inner drain port
diometes Ø 25mm and pipe fittings
• Be sure to install heat insulation on the drain piping.
1/50~1/100
Heat insulation material: Polyethylene foam with
thickness more than 8 mm. MAX 700mm

Drain test
The air conditioner uses a drain pump to drain water.
Use the following procedure to test the drain pump operation:
Indoor Units

Feed water Flexible drain hose


(accessory) • Connect the main drain pipe to the exterior and leave it pro-
Main visionally until the test comes to an end.
drain pipe
• Feed water to the flexible drain hose and check the piping
Drain for leakage.
Drain Pump port Glue the joint
• Be sure to check the drain pump for normal operating and
Drain hose connection
Use the clip (accessory) noise when electrical wiring is complete.
• When the test is complete, connect the flexible drain hose to
the drain port on the indoor unit.
Drain pan

Hanger
CAUTION Max 300mm distance
1~15m
Hanger Bracket
1/50~1/100 slope
Metal

Max 700mm
The supplied flexible drain hose should not be strained. clamp
A strained hose may cause leakage of water.
Flexible drain hose
Insulation

CAUTION
After the confirmation of the above conditions, prepare the wiring as follows:
1) Never fail to have separate power specially for the air conditioner. As for the method of wiring, follow the circuit diagram pasted on the
inside of control box cover.
2) Provide a circuit breaker switch between power source and the unit.
3) The screw which fasten the wiring in the casing of electrical fittings are liable to come loose from vibrations to which the unit is sub-
jected during the course of transportation. Check them and make sure that they are all tightly fastened. (If they are loose, it could give
rise to burn-out of the wires.)
4) Confirm the specification of power source
5) Confirm that electrical capacity is sufficient.
6) Be sure that the starting voltage is maintained at more than 90 percent of the rated voltage marked on the name plate.
7) Confirm that the cable thickness is as specified in the power sources specification.
(Particularly note the relation between cable length and thickness.)
8) Do not install the leakage breaker in a place which is wet or moist.
Water or moist may cause short circuit.
9) The following troubles would be caused by voltage drop-down.
• Vibration of a magnetic switch, damage on the contact point there of, fuse breaking, disturbance to the normal function of a overload protec-
tion device.
• Proper starting power is not given to the compressor.

HAND OVER
Teach the customer the operation and maintenance procedures, using the operation manual (air filter cleaning, temperature control, etc.).

36 _ Ceiling Cassette 4-way


10. Installation
WIRED REMOTE CONTROLLER INSTALLATION
• Since the room temperature sensor is in the remote controller, the remote controller box should be installed in a place
away from direct sunlight, high humidity and direct supply of cold air to maintain proper space temperature.
Install the remote controller about 5ft(1.5m) above the floor in an area with good air circulation at an average tempera-
ture.
Do not install the remote controller where it can be affected by:
- Drafts, or dead spots behind doors and in corners.
- Hot or cold air from ducts.
- Radiant heat from sun or appliances.
- Concealed pipes and chimneys.
- Uncontrolled areas such as an outside wall behind the remote controller.
- This remote controller is equipped with a seven segment LED. display. For proper display of the remote controller LED's,
the remote controller should be installed properly as shown in Fig.1.
(The standard height is 1.2~1.5 m from floor level.)

Indoor Units
Remote Controller
TEMP
yes

no
TEMP

Remote Controller

no
TEMP
5feet
Remote
Controller

(1.5meters)

no

Fig.1 Typical locations for remote controller

Ceiling Cassette 4-way _ 37


11. Accessories
Standard Accessories
Washer for Clamp Insulation for
Name Drain hose Clamp metal Bolt (Other)
hanging backet (Tie Wrap) fitting

Quantity 1 EA 2 EA 8 EA 4 EA 1 SET 4 EA

• Paper pattern for


installation
• Owner's manual
• Installation manual
Shape for gas pipe

for liquid pipe


Indoor Units

CAUTION
• Use only those accessories (Standard or optional) which have designated specifications.

38 _ Ceiling Cassette 4-way


Indoor unit

Ceiling Concealed Duct (High Static)


1. List of functions

2. Specifications

3. Dimensions & Gravity point

4. Piping Diagrams

5. Wiring Diagrams

6. Capacity Tables

7. External Static Pressure(E.S.P) & Air Flow

8. Electric Characteristics

9. Sound Levels

10. Installation

11. Accessories
1. List of functions
ARNU07GBHA2, ARNU09GBHA2, ARNU12GBHA2, ARNU15GBHA2, ARNU18GBHA2,
Category Function ARNU24GBHA2, ARNU28GBGA2 , ARNU36GBGA2, ARNU42GBGA2, ARNU48GBRA2,
ARNU54GBRA2, ARNU76GB8A2, ARNU96GB8A2
Air supply outlet 1
Airflow direction control(left & right) -
Airflow direction control(up & down) -
Auto swing(left & right) -
Auto swing(up & down) -
Air flow
Airflow steps(fan/cool/heat) 3/3/3
Chaos swing -
Chaos wind(auto wind) -
Jet cool(Power wind) -
Swirl wind -
Deodorizing filter X
Air purifying Plasma air purifier X
Prefilter(washable / anti-fungus) O
Drain pump O
E.S.P. control O
Installation

Indoor Units
Electric heater(operation) X
High ceiling operation -
Hot start O
Reliability Self diagnosis O
Soft dry operation O
Auto changeover O(Heat recovery)
Auto cleaning X
Auto operation(artificial intelligence) O(Heat pump or Cooling only)
Auto restart operation O
Child lock O
Convenience Forced operation -
Group control O
Sleep mode O
Timer(on/off) O
Timer(weekly) O
Two thermistor control O
Wide wired remote controller PQRCVSL0/PQRCVSL0QW
Deluxe wired remote controller PQRCUDS0(B/S)
Individual Simple wired remote controller PQRCVCL0Q(W)
control Wired remote controller(for hotel use) PQRCHCA0Q(W)
Wireless LCD remote control PQWRH(C)Q0FDB
Zone control X
CTIE -
Special Electro thermostat -
function kit Remote temperature sensor PQRSTA0
Group control wire PZCWRCG3
Dry contact PQDSA(1)/PQDSB(1)/PQDSBC/PQDSBNGCM1/PQDSBCGCD0

O : Applied X : Not applied – : No relation


Option : Model name & price are different according to options, and assembled in factory with main unit.
Accessory : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate
package.

Ceiling Concealed Duct(High Static) _ 1


2. Specifications
Type Ceiling Concealed Duct -High Static
Model Unit ARNU07GBHA2 ARNU09GBHA2 ARNU12GBHA2 ARNU15GBHA2
kW 2.2 2.8 3.6 4.5
Cooling Capacity kcal/h 1,900 2,400 3,100 3,900
Btu/h 7,500 9,600 12,300 15,400
kW 2.5 3.2 4.0 5.0
Heating Capacity kcal/h 2,200 2,800 3,400 4,300
Btu/h 8,500 10,900 13,600 17,100
Casing Galvanized Steel Plate Galvanized Steel Plate Galvanized Steel Plate Galvanized Steel Plate
mm 882 x 260 x 450 882 x 260 x 450 882 x 260 x 450 882 x 260 x 450
Dimensions(WxHxD) Body
inch 34-23/32 x 10-1/4 x 17-23/32 34-23/32 x 10-1/4 x 17-23/32 34-23/32 x 10-1/4 x 17-23/32 34-23/32 x 10-1/4 x 17-23/32
Coil Rows x Columns x FPI 2 x 10 x 21 2 x 10 x 21 2 x 10 x 21 2 x 10 x 21
Face Area m2 0.15 0.15 0.15 0.15
Type Sirocco Fan Sirocco Fan Sirocco Fan Sirocco Fan
Motor Output x Number W 118 118 118 118
Running Current A 0.92 0.92 0.92 0.92
Air Flow Rate(H / M / L) CMM 6.5 / 5.8 / 5.4 8.1 / 6.5 / 5.8 9.6 / 8.1 / 6.5 11.3 / 9.6 / 6.5
(High Mode-factory set) cfm 230 / 205 / 191 286 / 230 / 205 339 / 286 / 230 399 / 339 / 230
Indoor Units

Fan External Static Pressure mmAq(Pa) 8(78) 8(78) 8(78) 8(78)


Air Flow Rate(H / M / L) CMM 7.3 / 6.3 / 5.6 7.3 / 6.3 / 5.6 8.7 / 7.3 / 5.6 11.0 / 10.1 / 8.7
(Standard Mode) cfm 258 / 222 / 198 258 / 222 / 198 307 / 258 / 198 388 / 357 / 307
External Static Pressure mmAq(Pa) 6(59) 6(59) 6(59) 6(59)
Drive Direct Direct Direct Direct
Motor type BLDC BLDC BLDC BLDC
Temperature Control Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating
Sound Absorbing Thermal Insulation Material Foamed polystrene Foamed polystrene Foamed polystrene Foamed polystrene
Air Filter - - - -
Safety Device Fuse Fuse Fuse Fuse
Liquid Side mm(inch) Ø6.35(1/4) Ø6.35(1/4) Ø6.35(1/4) Ø6.35(1/4)
Pipe Connections Gas Side mm(inch) Ø12.7(1/2) Ø12.7(1/2) Ø12.7(1/2) Ø12.7(1/2)
Drain Pipe(Internal Dia.) mm(inch) 25(1) 25(1) 25(1) 25(1)
Net Weight kg(lbs) 26(57.4) 26(57.4) 26(57.4) 26(57.4)
Noise Level(Sound Pressure, 1.5m, H / M / L) dB(A) 26 / 25 / 23 26 / 25 / 23 27 / 26 / 23 28 / 27 / 25
Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50
1, 220, 60 1, 220, 60 1, 220, 60 1, 220, 60
Refrigerant Control EEV EEV EEV EEV
Power cable mm2 CV1.5 x 3C CV1.5 x 3C CV1.5 x 3C CV1.5 x 3C
Transmission cable mm2 CVV-SB 1.0~1.5 x 2C CVV-SB 1.0~1.5 x 2C CVV-SB 1.0~1.5 x 2C CVV-SB 1.0~1.5 x 2C

Notes:
Conversion Formula
1. Capacities are based on the following conditions:
Cooling • Indoor temp. 27°C[80.6°F]DB/ 19°C[66.2°F]WB kcal/h= kW x 860
• Outdoor temp. 35°C[95°F]DB/ 24°C[75.2°F]WB Btu/h = kW x 3412
• Interconnecting Piping Length 7.5m cfm = m3/min x 35.3
• Level Difference of Zero l/s = CMM x 1000/60
Heating • Indoor temp. 20°C[68°F]DB/ 15°C[59°F]WB
• Outdoor temp. 7°C[44.6°F]DB/ 6°C[42.8°F]WB
• Interconnecting Piping Length 7.5m
• Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. EEV : Electronic Expansion Valve
5. Sound pressure levels are measured at 50Pa External Static Pressure condition.
6. Anechoic chamber conversion value is measured at 1.5 m downward from unit centre.
The values depends on the ambient conditions and values are normally higher in actual operation.

2 _ Ceiling Concealed Duct(High Static)


2. Specifications
Type Ceiling Concealed Duct(High Static)
Model Unit ARNU18GBHA2 ARNU24GBHA2 ARNU28GBGA2
kW 5.6 7.1 8.2
Cooling Capacity kcal/h 4,800 6,100 7,100
Btu/h 19,100 24,200 28,000
kW 6.3 8.0 9.2
Heating Capacity kcal/h 5,400 6,900 8,000
Btu/h 21,500 27,300 31,500
Casing Galvanized Steel Plate Galvanized Steel Plate Galvanized Steel Plate
mm 882 x 260 x 450 882 x 260 x 450 1,182 x 298 x 450
Dimensions(WxHxD) Body
inch 34-23/32 x 10-1/4 x 17-23/32 34-23/32 x 10-1/4 x 17-23/32 46-17/32 x 11-23/32 x 17-23/32
Coil Rows x Columns x FPI 3 x 10 x 21 3 x 10 x 21 3 x 12 x 21
Face Area m2 0.15 0.15 0.26
Type Sirocco Fan Sirocco Fan Sirocco Fan
Motor Output x Number W 118 118 350
Running Current A 0.92 0.92 2.30
Air Flow Rate(H / M / L) CMM 13.0 / 11.3 / 9.6 16.0 / 14.4 / 13.0 25.9 / 24.1 / 21.8

Indoor Units
(High Mode-factory set) cfm 459 / 399 / 339 565 / 509 / 459 915 / 851 / 770
Fan External Static Pressure mmAq(Pa) 8(78) 8(78) 10(98)
Air Flow Rate(H / M / L) CMM 13.2 / 11.7 / 7.3 17.5 / 14.7 / 12.6 25.3 / 21.8 / 17.6
(Standard Mode) cfm 466 / 413 / 258 618 / 519 / 445 893 / 770 / 622
External Static Pressure mmAq(Pa) 6(59) 6(59) 8(78)
Drive Direct Direct Direct
Motor type BLDC BLDC BLDC
Temperature Control Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating
Sound Absorbing Thermal Insulation Material Foamed polystrene Foamed polystrene Foamed polystrene
Air Filter - - -
Safety Device Fuse Fuse Fuse
Liquid Side mm(inch) Ø6.35(1/4) Ø9.52(3/8) Ø9.52(3/8)
Pipe Connections Gas Side mm(inch) Ø12.7(1/2) Ø15.88(5/8) Ø15.88(5/8)
Drain Pipe(Internal Dia.) mm(inch) 25(1) 25(1) 25(1)
Net Weight kg(lbs) 26.5(58.4) 26.5(58.4) 38.0(83.8)
Noise Level(Sound Pressure, 1.5m, H / M / L) dB(A) 30 / 29 / 26 33 / 31 / 28 29 / 25 / 23
Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50
1, 220, 60 1, 220, 60 1, 220, 60
Refrigerant Control EEV EEV EEV
Power cable mm2 CV1.5 x 3C CV1.5 x 3C CV1.5 x 3C
Transmission cable mm2 CVV-SB 1.0~1.5 x 2C CVV-SB 1.0~1.5 x 2C CVV-SB 1.0~1.5 x 2C
Notes:
Conversion Formula
1. Capacities are based on the following conditions:
Cooling • Indoor temp. 27°C[80.6°F]DB/ 19°C[66.2°F]WB kcal/h= kW x 860
• Outdoor temp. 35°C[95°F]DB/ 24°C[75.2°F]WB Btu/h = kW x 3412
• Interconnecting Piping Length 7.5m cfm = m3/min x 35.3
• Level Difference of Zero l/s = CMM x 1000/60
Heating • Indoor temp. 20°C[68°F]DB/ 15°C[59°F]WB
• Outdoor temp. 7°C[44.6°F]DB/ 6°C[42.8°F]WB
• Interconnecting Piping Length 7.5m
• Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. EEV : Electronic Expansion Valve
5. Sound pressure levels are measured at 50Pa External Static Pressure condition.
6. Anechoic chamber conversion value is measured at 1.5 m downward from unit centre.
The values depends on the ambient conditions and values are normally higher in actual operation.

Ceiling Concealed Duct(High Static) _ 3


2. Specifications
Type Ceiling Concealed Duct(High Static)
Model Unit ARNU36GBGA2 ARNU42GBGA2 ARNU48GBRA2
kW 10.6 12.3 14.1
Cooling Capacity kcal/h 9,100 10,600 12,100
Btu/h 36,200 42,000 48,100
kW 11.9 13.8 15.9
Heating Capacity kcal/h 10,200 11,000 13,200
Btu/h 40,600 43,800 51,200
Casing Galvanized Steel Plate Galvanized Steel Plate Galvanized Steel Plate
mm 1,182 x 298 x 450 1,182 x 298 x 450 1,230 x 380 x 590
Dimensions(WxHxD) Body
inch 46-17/32 x 11-23/32 x 17-23/32 46-17/32 x 11-23/32 x 17-23/32 48-7/16 x 14-31/32 x 23-7/32
Rows x Columns x FPI 3 x 12 x 21 3 x 12 x 21 3 x 13 x 19
Coil
Face Area m2 0.26 0.26 0.38
Type Sirocco Fan Sirocco Fan Sirocco Fan
Motor Output x Number W 350 350 185 x 2
Running Current A 2.30 2.30 2.40
Air Flow Rate(H / M / L) CMM 32.3 / 29.0 / 25.3 34.5 / 32.3 / 30.7 44.8 / 40.6 / 33.3
Indoor Units

(High Mode-factory set) cfm 1,141 / 1,024 / 894 1,218 / 1,141 / 1,084 1,582 / 1,434 / 1,176
Fan External Static Pressure mmAq(Pa) 10(98) 10(98) 14(137)
Air Flow Rate(H / M / L) CMM 28.4 / 25.3 / 21.8 32.0 / 28.4 / 27.2 44.4 / 39.5 / 33.5
(Standard Mode) cfm 1,003 / 894 / 770 1,130 / 1,003 / 961 1,568 / 1,395 / 1,183
External Static Pressure mmAq(Pa) 8(78) 8(78) 10(98)
Drive Direct Direct Direct
Motor type BLDC BLDC BLDC
Temperature Control Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating
Sound Absorbing Thermal Insulation Material Foamed polystrene Foamed polystrene Foamed polystrene
Air Filter - - -
Safety Device Fuse Fuse Fuse
Liquid Side mm(inch) Ø9.52(3/8) Ø9.52(3/8) Ø9.52(3/8)
Pipe Connections Gas Side mm(inch) Ø15.88(5/8) Ø15.88(5/8) Ø15.88(5/8)
Drain Pipe(Internal Dia.) mm(inch) 25(1) 25(1) 25(1)
Net Weight kg(lbs) 38(83.8) 38(83.8) 53(117)
Noise Level(Sound Pressure, 1.5m, H / M / L) dB(A) 33 / 31 / 28 36 / 33 / 30 38 / 36 / 34
1, 220-240, 50 1, 220-240, 50 1, 220-240, 50
Power Supply Ø, V, Hz
1, 220, 60 1, 220, 60 1, 220, 60
Refrigerant Control EEV EEV EEV
Power cable mm2 CV1.5 x 3C CV1.5 x 3C CV1.5 x 3C
Transmission cable mm2 CVV-SB 1.0~1.5 x 2C CVV-SB 1.0~1.5 x 2C CVV-SB 1.0~1.5 x 2C

Notes: Conversion Formula


1. Capacities are based on the following conditions:
kcal/h= kW x 860
Cooling • Indoor temp. 27°C[80.6°F]DB/ 19°C[66.2°F]WB
Btu/h = kW x 3412
• Outdoor temp. 35°C[95°F]DB/ 24°C[75.2°F]WB
cfm = m3/min x 35.3
• Interconnecting Piping Length 7.5m
l/s = CMM x 1000/60
• Level Difference of Zero
Heating • Indoor temp. 20°C[68°F]DB/ 15°C[59°F]WB
• Outdoor temp. 7°C[44.6°F]DB/ 6°C[42.8°F]WB
• Interconnecting Piping Length 7.5m
• Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. EEV : Electronic Expansion Valve
5. Sound pressure levels are measured at 50Pa External Static Pressure condition.
6. Anechoic chamber conversion value is measured at 1.5 m downward from unit centre.
The values depends on the ambient conditions and values are normally higher in actual operation.

4 _ Ceiling Concealed Duct(High Static)


2. Specifications
Type Ceiling Concealed Duct(High Static)
Model Unit ARNU54GBRA2 ARNU76GB8A2 ARNU96GB8A2
kW 15.8 22.4 28.0
Cooling Capacity kcal/h 13,600 19,300 24,100
Btu/h 54,000 76,400 95,900
kW 18.0 25.2 31.5
Heating Capacity kcal/h 15,500 21,700 27,100
Btu/h 61,400 86,000 107,500
Casing Galvanized Steel Plate Galvanized Steel Plate Galvanized Steel Plate
mm 1,230 x 380 x 590 1,562 x 460 x 688 1,562 x 460 x 688
Dimensions(WxHxD) Body
inch 48-7/16 x 14-31/32 x 23-7/32 61-1/2 x 18-1/8 x 27-3/32 61-1/2 x 18-1/8 x 27-3/32
Coil Rows x Columns x FPI 3 x 13 x 19 3 x 21 x 19 3 x 21 x 19
Face Area m2 0.38 0.59 0.59
Type Sirocco Fan Sirocco Fan Sirocco Fan
Motor Output x Number W 185 x 2 375 x 2 375 x 2
Running Current A 3.00 5.12 5.12
Air Flow Rate(H / M / L) CMM 51.0 / 44.8 / 40.6 60.0 / 50.0 / 50.0 72.0 / 64.0 / 64.0

Indoor Units
(High Mode-factory set) cfm 1,801 / 1,582 / 1,434 2,119 / 1,766 / 1,766 2542 / 2,260 / 2,260
Fan External Static Pressure mmAq(Pa) 14(137) 22(216) 22(216)
Air Flow Rate(H / M / L) CMM 51.5 / 47.5 / 39.5 64.0 / 50.0 / 50.0 76.0 / 64.0 / 64.0
(Standard Mode) cfm 1,819 / 1,678 / 1,395 2,260 / 1,766 / 1,766 2,684 / 2,260 / 2,260
External Static Pressure mmAq(Pa) 10(98) 15(147) 15(147)
Drive Direct Direct Direct
Motor type BLDC BLDC BLDC
Temperature Control Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating
Sound Absorbing Thermal Insulation Material Foamed polystrene Foamed polystrene Foamed polystrene
Air Filter - - -
Safety Device Fuse Fuse Fuse
Liquid Side mm(inch) Ø9.52(3/8) Ø9.52(3/8) Ø9.52(3/8)
Pipe Connections Gas Side mm(inch) Ø15.88(5/8) Ø19.05(3/4) Ø22.2(7/8)
Drain Pipe(Internal Dia.) mm(inch) 25(1) 25(1) 25(1)
Net Weight kg(lbs) 53(117) 87(192) 87(192)
Noise Level(Sound Pressure, 1.5m, H / M / L) dB(A) 39 / 37 / 35 45 / 41 / 40 47 / 42 / 41
1, 220-240, 50 1, 220-240, 50 1, 220-240, 50
Power Supply Ø, V, Hz
1, 220, 60 1, 220, 60 1, 220, 60
Refrigerant Control EEV EEV EEV
Power cable mm2 CV1.5 x 3C CV1.5 x 3C CV1.5 x 3C
Transmission cable mm2 CVV-SB 1.0 ~ 1.5 × 2C CVV-SB 1.0~1.5 x 2C CVV-SB 1.0~1.5 x 2C
Notes:
Conversion Formula
1. Capacities are based on the following conditions:
Cooling • Indoor temp. 27°C[80.6°F]DB/ 19°C[66.2°F]WB kcal/h= kW x 860
• Outdoor temp. 35°C[95°F]DB/ 24°C[75.2°F]WB Btu/h = kW x 3412
• Interconnecting Piping Length 7.5m cfm = m3/min x 35.3
• Level Difference of Zero l/s = CMM x 1000/60
Heating • Indoor temp. 20°C[68°F]DB/ 15°C[59°F]WB
• Outdoor temp. 7°C[44.6°F]DB/ 6°C[42.8°F]WB
• Interconnecting Piping Length 7.5m
• Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. EEV : Electronic Expansion Valve
5. Sound pressure levels are measured at External Static Pressure condition like below.
- ARNU54GBRA2 : 50 Pa
- ARNU76GB8A2 / ARNU96GB8A2 (H/M/L) : 220 / 150 / 120 Pa
6. Anechoic chamber conversion value is measured at 1.5 m downward from unit centre.
The values depends on the ambient conditions and values are normally higher in actual operation.

Ceiling Concealed Duct(High Static) _ 5


Indoor Units

745 115 4 Ceiling Concealed Duct (High Static)

20
ARNU07GBHA2

175
ARNU09GBHA2
ARNU12GBHA2
ARNU15GBHA2
6 ARNU18GBHA2
49 101
ARNU24GBHA2
932 51 31
70
24
29
48
50
114 52 165 (unit : mm)

224
R3
7.
5
100 Number Name Descripition

355
60

450

355

450
Unit size(7k,9k,12k,18k):ø6.35
123 140
1 Liquid pipe connection Unit size(24k):ø9.52

219
1

133
Unit size(7k,9k,12k,18k):ø12.7
47 47 2
2 Gas pipe connection Unit size(24k):ø15.88
21

6 _ Ceiling Concealed Duct(High Static)


428
3 3 Drain pipe connection
30 260
87 4 Power supply connection
750
5 5 Air discharge
3. Dimensions & Gravity point

882 108
6 Air suction
65

75

127

158
Note

260
106
119
1. Unit should be installed in compliance with the installation manual
in the product box.
64 243 212 243 119 2. Unit shall be grounded in accordance with the local regulations or
applicable national codes.

450
Gravity point

882

76, Seongsan-dong, Changwon City, Gyeongnam,


641-713, Korea CHASSIS CODE: BH
4 Ceiling Concealed Duct (High Static)
1,043 115
ARNU28GBGA2

20
ARNU36GBGA2
ARNU42GBGA2

220
(unit : mm)
6
1,232 Number Name Descripition
102
51 32 1 Liquid pipe connection Unit size(28k,36k,42k):ø9.52
23

47 2 Gas pipe connection Unit size(28k,36k,42k):ø15.88


50
152 53 165
ø1

224
00 3 Drain pipe connection
100

450
60

355
4 Power supply connection
122 140 5 Air discharge

219
87 1
6 Air suction
2
49
565 3
30 77 261
87
830
5
3. Dimensions & Gravity point

1,182 108

Note

158

186
1. Unit should be installed in compliance with the installation manual

298
in the product box.

113
136
2. Unit shall be grounded in accordance with the local regulations or
232 243 232 243 232 applicable national codes.

Gravity point

450
1,182

76, Seongsan-dong, Changwon City, Gyeongnam,


641-713, Korea CHASSIS CODE: BG

Ceiling Concealed Duct(High Static) _ 7


Indoor Units
Indoor Units

Ceiling Concealed Duct (High Static)


1,092 120 4
ARNU48GBRA2

25
ARNU54GBRA2

303
(unit : mm)
6 101
1,282 Number Name Descripition
83
1,230 115 26 1 Liquid pipe connection Unit size(48k):ø9.52

72
2 Gas pipe connection Unit size(48k):ø15.88

123
221
198
3 Drain pipe connection

312
R6
0

90
60 4 Power supply connection

477
590
5 Air discharge

122
144
1

302
2 6 Air suction

56
50 3

8 _ Ceiling Concealed Duct(High Static)


114

32
621 135
118 190
1,006 260
5
Note
3. Dimensions & Gravity point

1. Unit should be installed in compliance with the installation manual


in the product box.

178

140
2. Unit shall be grounded in accordance with the local regulations or

294

380
applicable national codes.

177
174
215 279 241 279 215
1,004 Gravity point

590
1,230

76, Seongsan-dong, Changwon City, Gyeongnam,


641-713, Korea CHASSIS CODE: BR
4 Ceiling Concealed Duct (High Static)
1,400 115
ARNU76GB8A2

20
ARNU96GB8A2

440
2

70
6 120
460 1,622
1,565 3
40
99 1

58 1
18
(unit : mm)

122 60 70 64
Number Name Descripition
109

688
580
68 1 Liquid pipe connection Unit size(76k,96k):ø9.52
358

397
Unit size(76k):ø19.05
2 Gas pipe connection Unit size(96k):ø22.2

64
819 3 Drain pipe connection

30
1,122
3. Dimensions & Gravity point

4 Power supply connection


5 5 Air discharge
6 Air suction

292

318
Note

460
1. Unit should be installed in compliance with the installation manual

222
161
in the product box.

293 329 320 329 118 2. Unit shall be grounded in accordance with the local regulations or
applicable national codes.

Gravity point

695
1,562

76, Seongsan-dong, Changwon City, Gyeongnam,


641-713, Korea CHASSIS CODE: B8

Ceiling Concealed Duct(High Static) _ 9


Indoor Units
4. Piping Diagrams
BH, BG, BR Chassis
:Cooling
Heat Exchanger EEV :Heating
Filter

Th3 Th2
Sirocco Fan Filter

Th1 lndoor unit


Indoor Units

Refrigerant pipe connection port diameter


[Unit: mm(inch)]

MODEL GAS LIQUID


ARNU07GBHA2 Ø12.7(1/2) Ø6.35(1/4)
ARNU09GBHA2 Ø12.7(1/2) Ø6.35(1/4)
ARNU12GBHA2 Ø12.7(1/2) Ø6.35(1/4)
ARNU15GBHA2 Ø12.7(1/2) Ø6.35(1/4)
ARNU18GBHA2 Ø12.7(1/2) Ø6.35(1/4)
ARNU24GBHA2 Ø15.88(5/8) Ø9.52(3/8)
ARNU28GBGA2 Ø15.88(5/8) Ø9.52(3/8)
ARNU36GBGA2 Ø15.88(5/8) Ø9.52(3/8)
ARNU42GBGA2 Ø15.88(5/8) Ø9.52(3/8)
ARNU48GBRA2 Ø15.88(5/8) Ø9.52(3/8)
ARNU54GBRA2 Ø15.88(5/8) Ø9.52(3/8)

LOC. Description
Th1 Room thermistor
Th2 Pipe in thermistor
Th3 Pipe out thermistor

10 _ Ceiling Concealed Duct(High Static)


4. Piping Diagrams
B8 Chassis

General information
:Cooling
Heat Exchanger EEV :Heating

Indoor unit
Filter

Th3 Th2 Check


Sirocco Fan Valve

Filter

Th1 lndoor unit

Refrigerant pipe connection port diameter


[Unit: mm(inch)]

MODEL GAS LIQUID

ARNU76GB8A2 Ø19.05(3/4) Ø9.52(3/8)

ARNU96GB8A2 Ø22.2(7/8) Ø9.52(3/8)

LOC. Description
Th1 Room thermistor
Th2 Pipe in thermistor
Th3 Pipe out thermistor

Ceiling Concealed Duct(High Static) _ 11


5. Wiring Diagrams
BH Chassis
Indoor Units

CONNECTOR NUMBER LOCATION POINT FUNCTION


CN-POWER AC Power supply AC Power line input for indoor controller
CN-MOTOR1 Fan motor output Motor output of BLDC
CN-D/PUMP Drain pump output AC output for drain pump
CN-COM Communication Connection between indoor and outdoor
CN-EEV EEV Output EEV Control output
CN-FLOAT Float switch input Float switch sensing
CN-PIPE/IN Suction pipe sensor Pipe in thermistor
CN-PIPE/OUT Discharge pipe sensor Pipe out thermistor
CN-ROOM Room sensor Room air thermistor
CN-REMO Remote controller Remote control line
CN-ZONE Zontroller Zone control line
CN-DISPLAY RF Remote controller RF Remote control line
CN-CC Dry contact Dry contact line

Dip Switch Setting Off On Remarks


SW3 GROUP Master Slave Group Control setting using Wired Remote Controller
Old Dry Contact Mode Setting
1. Variable : Auto/Manual Mode can be chosen by Wide wired
SW4 DRY CONTACT Variable Auto remote controller or Wireless remote controller
(When shipped from Factory ’ Manual Mode)
2. Auto : For Dry Contact, it is always Auto mode.
1. Duct model
-. OFF : Default(not operate continuosly )
-. ON : Fan operate continuosly
SW5 EXTRA 1 Off On 2. Cassette Model : No Function
3. Ceiling Suspended Model
-. OFF : Ceiling(default)
-. ON : Floor

CAUTION
For Multi V Model, Dip Switch 1,2,6,7,8 must be set OFF
That dip switch is used for the other model.

12 _ Ceiling Concealed Duct(High Static)


5. Wiring Diagrams
BG Chassis

Indoor Units
CONNECTOR NUMBER LOCATION POINT FUNCTION
CN-POWER AC Power supply AC Power line input for indoor controller
CN-MOTOR1 Fan motor output Motor output of BLDC
CN-MOTOR2 Fan motor output Motor output of BLDC
CN-D/PUMP Drain pump output AC output for drain pump
CN-COM Communication Connection between indoor and outdoor
CN-EEV EEV Output EEV Control output
CN-FLOAT Float switch input Float switch sensing
CN-PIPE/IN Suction pipe sensor Pipe in thermistor
CN-PIPE/OUT Discharge pipe sensor Pipe out thermistor
CN-ROOM Room sensor Room air thermistor
CN-REMO Remote controller Remote control line
CN-ZONE Zontroller Zone control line
CN-DISPLAY RF Remote controller RF Remote control line
CN-CC Dry contact Dry contact line
Dip Switch Setting Off On Remarks
SW3 GROUP Master Slave Group Control setting using Wired Remote Controller
Old Dry Contact Mode Setting
1. Variable : Auto/Manual Mode can be chosen by Wide wired
SW4 DRY CONTACT Variable Auto remote controller or Wireless remote controller
(When shipped from Factory ’ Manual Mode)
2. Auto : For Dry Contact, it is always Auto mode.
1. Duct model
-. OFF : Default(not operate continuosly )
-. ON : Fan operate continuosly
SW5 EXTRA 1 Off On 2. Cassette Model : No Function
3. Ceiling Suspended Model
-. OFF : Ceiling(default)
-. ON : Floor

CAUTION
For Multi V Model, Dip Switch 1,2,6,7,8 must be set OFF
That dip switch is used for the other model.

Ceiling Concealed Duct(High Static) _ 13


5. Wiring Diagrams
BR Chassis
Indoor Units

CONNECTOR NUMBER LOCATION POINT FUNCTION


CN-POWER AC Power supply AC Power line input for indoor controller
CN-MOTOR1 Fan motor output Motor output of BLDC
CN-MOTOR2 Fan motor output Motor output of BLDC
CN-D/PUMP Drain pump output AC output for drain pump
CN-COM Communication Connection between indoor and outdoor
CN-EEV EEV Output EEV Control output
CN-FLOAT Float switch input Float switch sensing
CN-PIPE/IN Suction pipe sensor Pipe in thermistor
CN-PIPE/OUT Discharge pipe sensor Pipe out thermistor
CN-ROOM Room sensor Room air thermistor
CN-REMO Remote controller Remote control line
CN-ZONE Zontroller Zone control line
CN-DISPLAY RF Remote controller RF Remote control line
CN-CC Dry contact Dry contact line
Dip Switch Setting Off On Remarks
SW3 GROUP Master Slave Group Control setting using Wired Remote Controller
Old Dry Contact Mode Setting
1. Variable : Auto/Manual Mode can be chosen by Wide wired
SW4 DRY CONTACT Variable Auto remote controller or Wireless remote controller
(When shipped from Factory ’ Manual Mode)
2. Auto : For Dry Contact, it is always Auto mode.
1. Duct model
-. OFF : Default(not operate continuosly )
-. ON : Fan operate continuosly
SW5 EXTRA 1 Off On 2. Cassette Model : No Function
3. Ceiling Suspended Model
-. OFF : Ceiling(default)
-. ON : Floor

CAUTION
For Multi V Model, Dip Switch 1,2,6,7,8 must be set OFF
That dip switch is used for the other model.

14 _ Ceiling Concealed Duct(High Static)


5. Wiring Diagrams
B8 Chassis

Indoor Units
CONNECTOR NUMBER LOCATION POINT FUNCTION
CN-POWER AC Power supply AC Power line input for indoor controller
CN-MOTOR1, CN-MOTOR2 Fan motor output Motor output of BLDC
CN-D/PUMP Drain pump output AC Output for drain pump
CN-COM Communication Connection between indoor and outdoor
CN-EEV EEV Output EEV Control output
CN-FLOAT Float switch input Float switch sensing
CN-PIPE/IN Suction pipe sensor Pipe in thermistor
CN-PIPE/OUT Discharge pipe sensor Pipe out thermistor
CN-ROOM Room sensor Room thermistor
CN-REMO Remote controller Remote control line
CN-CC Dry contact Dry contact line
CN-DISPLAY RF Remocon RF Remocon receiver
CN-OPTION Option PCB Option PCB connector
CN-ZONE Zone controller Zone controller line
Dip Switch Setting Off On Remarks
SW3 GROUP Master Slave Group Control setting using Wired Remote Controller
Old Dry Contact Mode Setting
1. Variable : Auto/Manual Mode can be chosen by Wide wired
SW4 DRY CONTACT Variable Auto remote controller or Wireless remote controller
(When shipped from Factory ’ Manual Mode)
2. Auto : For Dry Contact, it is always Auto mode.
1. Duct model
-. OFF : Default(not operate continuosly )
-. ON : Fan operate continuosly
SW5 EXTRA 1 Off On 2. Cassette Model : No Function
3. Ceiling Suspended Model
-. OFF : Ceiling(default)
-. ON : Floor

CAUTION
For Multi V Model, Dip Switch 1,2,6,7,8 must be set OFF
That dip switch is used for the other model.

Ceiling Concealed Duct(High Static) _ 15


6. Capacity Tables
6.1 Cooling Capacity Cooling capacity

Indoor air temp. (DB/WB, °C)


Capacity Outdoor 20 23 26 27 28 30 32
Index air temp. 14 16 18 19 20 22 24
(DB, °C) TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10 1.5 1.4 1.8 1.5 2.0 1.7 2.2 1.7 2.4 1.8 2.6 1.8 2.9 1.8
12 1.5 1.4 1.8 1.5 2.0 1.7 2.2 1.7 2.4 1.8 2.6 1.8 2.9 1.8
14 1.5 1.4 1.8 1.5 2.0 1.7 2.2 1.7 2.4 1.8 2.6 1.8 2.8 1.8
16 1.5 1.4 1.8 1.5 2.0 1.7 2.2 1.7 2.4 1.8 2.6 1.8 2.8 1.7
18 1.5 1.4 1.8 1.5 2.0 1.7 2.2 1.7 2.4 1.8 2.6 1.8 2.7 1.7
20 1.5 1.4 1.8 1.5 2.0 1.7 2.2 1.7 2.4 1.8 2.6 1.8 2.7 1.7
21 1.5 1.4 1.8 1.5 2.0 1.7 2.2 1.7 2.4 1.8 2.6 1.8 2.7 1.7
23 1.5 1.4 1.8 1.5 2.0 1.7 2.2 1.7 2.4 1.8 2.6 1.8 2.6 1.7
2.2 25 1.5 1.4 1.8 1.5 2.0 1.7 2.2 1.7 2.4 1.8 2.6 1.8 2.6 1.6
27 1.5 1.4 1.8 1.5 2.0 1.7 2.2 1.7 2.4 1.8 2.5 1.8 2.6 1.6
29 1.5 1.4 1.8 1.5 2.0 1.7 2.2 1.7 2.4 1.8 2.5 1.7 2.5 1.6
31 1.5 1.4 1.8 1.5 2.0 1.7 2.2 1.7 2.4 1.8 2.5 1.7 2.5 1.6
Indoor Units

33 1.5 1.4 1.8 1.5 2.0 1.7 2.2 1.7 2.4 1.8 2.4 1.7 2.4 1.5
35 1.5 1.4 1.8 1.5 2.0 1.7 2.2 1.7 2.4 1.8 2.4 1.7 2.4 1.5
37 1.5 1.4 1.8 1.5 2.0 1.7 2.2 1.7 2.3 1.7 2.3 1.6 2.4 1.5
39 1.5 1.4 1.8 1.5 2.0 1.7 2.2 1.7 2.2 1.7 2.3 1.6 2.4 1.5
10 1.9 1.8 2.2 2.0 2.6 2.2 2.8 2.2 3.0 2.3 3.4 2.4 3.7 2.3
12 1.9 1.8 2.2 2.0 2.6 2.2 2.8 2.2 3.0 2.3 3.4 2.4 3.6 2.3
14 1.9 1.8 2.2 2.0 2.6 2.2 2.8 2.2 3.0 2.3 3.4 2.4 3.6 2.3
16 1.9 1.8 2.2 2.0 2.6 2.2 2.8 2.2 3.0 2.3 3.4 2.4 3.5 2.2
18 1.9 1.8 2.2 2.0 2.6 2.2 2.8 2.2 3.0 2.3 3.4 2.4 3.5 2.2
20 1.9 1.8 2.2 2.0 2.6 2.2 2.8 2.2 3.0 2.3 3.4 2.4 3.4 2.2
21 1.9 1.8 2.2 2.0 2.6 2.2 2.8 2.2 3.0 2.3 3.4 2.4 3.4 2.2
23 1.9 1.8 2.2 2.0 2.6 2.2 2.8 2.2 3.0 2.3 3.4 2.4 3.4 2.2
2.8 25 1.9 1.8 2.2 2.0 2.6 2.2 2.8 2.2 3.0 2.3 3.3 2.3 3.3 2.1
27 1.9 1.8 2.2 2.0 2.6 2.2 2.8 2.2 3.0 2.3 3.2 2.3 3.3 2.1
29 1.9 1.8 2.2 2.0 2.6 2.2 2.8 2.2 3.0 2.3 3.2 2.2 3.2 2.1
31 1.9 1.8 2.2 2.0 2.6 2.2 2.8 2.2 3.0 2.3 3.2 2.2 3.2 2.0
33 1.9 1.8 2.2 2.0 2.6 2.2 2.8 2.2 3.0 2.3 3.1 2.2 3.1 2.0
35 1.9 1.8 2.2 2.0 2.6 2.2 2.8 2.2 3.0 2.3 3.0 2.2 3.1 2.0
37 1.9 1.8 2.2 2.0 2.6 2.2 2.8 2.2 2.9 2.2 3.0 2.1 3.0 1.9
39 1.9 1.8 2.2 2.0 2.6 2.2 2.8 2.2 2.8 2.2 2.9 2.1 3.0 1.9
10 2.4 2.3 2.9 2.5 3.3 2.7 3.6 2.8 3.9 2.9 4.3 3.0 4.7 3.0
12 2.4 2.3 2.9 2.5 3.3 2.7 3.6 2.8 3.9 2.9 4.3 3.0 4.7 3.0
14 2.4 2.3 2.9 2.5 3.3 2.7 3.6 2.8 3.9 2.9 4.3 3.0 4.6 2.9
16 2.4 2.3 2.9 2.5 3.3 2.7 3.6 2.8 3.9 2.9 4.3 3.0 4.6 2.9
18 2.4 2.3 2.9 2.5 3.3 2.7 3.6 2.8 3.9 2.9 4.3 3.0 4.5 2.9
20 2.4 2.3 2.9 2.5 3.3 2.7 3.6 2.8 3.9 2.9 4.3 3.0 4.4 2.8
21 2.4 2.3 2.9 2.5 3.3 2.7 3.6 2.8 3.9 2.9 4.3 3.0 4.4 2.8
23 2.4 2.3 2.9 2.5 3.3 2.7 3.6 2.8 3.9 2.9 4.3 3.0 4.3 2.7
3.6 25 2.4 2.3 2.9 2.5 3.3 2.7 3.6 2.8 3.9 2.9 4.3 3.0 4.3 2.7
27 2.4 2.3 2.9 2.5 3.3 2.7 3.6 2.8 3.9 2.9 4.2 2.9 4.2 2.7
29 2.4 2.3 2.9 2.5 3.3 2.7 3.6 2.8 3.9 2.9 4.1 2.9 4.2 2.6
31 2.4 2.3 2.9 2.5 3.3 2.7 3.6 2.8 3.9 2.9 4.1 2.8 4.1 2.6
33 2.4 2.3 2.9 2.5 3.3 2.7 3.6 2.8 3.9 2.9 4.0 2.8 4.0 2.5
35 2.4 2.3 2.9 2.5 3.3 2.7 3.6 2.8 3.9 2.9 3.9 2.7 4.0 2.5
37 2.4 2.3 2.9 2.5 3.3 2.7 3.6 2.8 3.8 2.8 3.8 2.7 3.9 2.5
39 2.4 2.3 2.9 2.5 3.3 2.7 3.6 2.8 3.7 2.7 3.8 2.6 3.9 2.4

16 _ Ceiling Concealed Duct(High Static)


6. Capacity Tables
Cooling capacity

Indoor air temp. (DB/WB, °C)


Capacity Outdoor 20 23 26 27 28 30 32
Index air temp. 14 16 18 19 20 22 24
(DB, °C) TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10 3.0 2.9 3.6 3.2 4.2 3.4 4.5 3.5 4.8 3.6 5.4 3.8 5.9 3.7
12 3.0 2.9 3.6 3.2 4.2 3.4 4.5 3.5 4.8 3.6 5.4 3.8 5.8 3.7
14 3.0 2.9 3.6 3.2 4.2 3.4 4.5 3.5 4.8 3.6 5.4 3.8 5.8 3.6
16 3.0 2.9 3.6 3.2 4.2 3.4 4.5 3.5 4.8 3.6 5.4 3.8 5.7 3.6
18 3.0 2.9 3.6 3.2 4.2 3.4 4.5 3.5 4.8 3.6 5.4 3.8 5.6 3.6
20 3.0 2.9 3.6 3.2 4.2 3.4 4.5 3.5 4.8 3.6 5.4 3.8 5.5 3.5
21 3.0 2.9 3.6 3.2 4.2 3.4 4.5 3.5 4.8 3.6 5.4 3.8 5.5 3.5
23 3.0 2.9 3.6 3.2 4.2 3.4 4.5 3.5 4.8 3.6 5.4 3.8 5.4 3.4
4.5 25 3.0 2.9 3.6 3.2 4.2 3.4 4.5 3.5 4.8 3.6 5.3 3.7 5.3 3.4
27 3.0 2.9 3.6 3.2 4.2 3.4 4.5 3.5 4.8 3.6 5.2 3.6 5.3 3.4
29 3.0 2.9 3.6 3.2 4.2 3.4 4.5 3.5 4.8 3.6 5.1 3.6 5.2 3.3

Indoor Units
31 3.0 2.9 3.6 3.2 4.2 3.4 4.5 3.5 4.8 3.6 5.1 3.5 5.1 3.2
33 3.0 2.9 3.6 3.2 4.2 3.4 4.5 3.5 4.8 3.6 4.9 3.5 5.0 3.2
35 3.0 2.9 3.6 3.2 4.2 3.4 4.5 3.5 4.8 3.6 4.9 3.4 4.9 3.2
37 3.0 2.9 3.6 3.2 4.2 3.4 4.5 3.5 4.7 3.5 4.8 3.4 4.9 3.1
39 3.0 2.9 3.6 3.2 4.2 3.4 4.5 3.5 4.6 3.4 4.7 3.3 4.8 3.0
10 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 6.0 4.2 6.7 4.4 7.4 4.4
12 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 6.0 4.2 6.7 4.4 7.3 4.3
14 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 6.0 4.2 6.7 4.4 7.2 4.3
16 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 6.0 4.2 6.7 4.4 7.1 4.2
18 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 6.0 4.2 6.7 4.4 7.0 4.1
20 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 6.0 4.2 6.7 4.4 6.9 4.1
21 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 6.0 4.2 6.7 4.4 6.8 4.1
23 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 6.0 4.2 6.7 4.4 6.7 4.0
5.6 25 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 6.0 4.2 6.6 4.3 6.6 3.9
27 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 6.0 4.2 6.4 4.2 6.6 3.9
29 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 6.0 4.2 6.4 4.2 6.5 3.8
31 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 6.0 4.2 6.3 4.1 6.4 3.8
33 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 6.0 4.2 6.2 4.0 6.3 3.7
35 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 6.0 4.2 6.0 4.0 6.2 3.6
37 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 5.8 4.1 5.9 3.9 6.1 3.6
39 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 5.7 4.0 5.8 3.8 6.0 3.5
10 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 8.5 5.6 9.3 5.5
12 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 8.5 5.6 9.2 5.5
14 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 8.5 5.6 9.1 5.4
16 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 8.5 5.6 9.0 5.3
18 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 8.5 5.6 8.8 5.2
20 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 8.5 5.6 8.7 5.2
21 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 8.5 5.6 8.7 5.1
23 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 8.5 5.6 8.5 5.1
7.1 25 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 8.4 5.5 8.4 5.0
27 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 8.2 5.4 8.3 4.9
29 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 8.1 5.3 8.2 4.8
31 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 8.0 5.2 8.1 4.8
33 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 7.8 5.1 7.9 4.7
35 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 7.7 5.0 7.8 4.6
37 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.4 5.2 7.5 4.9 7.7 4.6
39 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.2 5.1 7.4 4.8 7.6 4.5

Ceiling Concealed Duct(High Static) _ 17


6. Capacity Tables
Cooling capacity

Indoor air temp. (DB/WB, °C)


Capacity Outdoor 20 23 26 27 28 30 32
Index air temp. 14 16 18 19 20 22 24
(DB, °C) TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10 5.5 5.0 6.6 5.5 7.7 6.0 8.2 6.1 8.7 6.2 9.8 6.5 10.8 6.5
12 5.5 5.0 6.6 5.5 7.7 6.0 8.2 6.1 8.7 6.2 9.8 6.5 10.6 6.4
14 5.5 5.0 6.6 5.5 7.7 6.0 8.2 6.1 8.7 6.2 9.8 6.5 10.5 6.3
16 5.5 5.0 6.6 5.5 7.7 6.0 8.2 6.1 8.7 6.2 9.8 6.5 10.4 6.2
18 5.5 5.0 6.6 5.5 7.7 6.0 8.2 6.1 8.7 6.2 9.8 6.5 10.2 6.1
20 5.5 5.0 6.6 5.5 7.7 6.0 8.2 6.1 8.7 6.2 9.8 6.5 10.1 6.0
21 5.5 5.0 6.6 5.5 7.7 6.0 8.2 6.1 8.7 6.2 9.8 6.5 10.0 6.0
23 5.5 5.0 6.6 5.5 7.7 6.0 8.2 6.1 8.7 6.2 9.8 6.5 9.9 5.9
8.2 25 5.5 5.0 6.6 5.5 7.7 6.0 8.2 6.1 8.7 6.2 9.7 6.4 9.7 5.8
27 5.5 5.0 6.6 5.5 7.7 6.0 8.2 6.1 8.7 6.2 9.4 6.3 9.6 5.8
29 5.5 5.0 6.6 5.5 7.7 6.0 8.2 6.1 8.7 6.2 9.3 6.2 9.5 5.7
Indoor Units

31 5.5 5.0 6.6 5.5 7.7 6.0 8.2 6.1 8.7 6.2 9.2 6.1 9.3 5.6
33 5.5 5.0 6.6 5.5 7.7 6.0 8.2 6.1 8.7 6.2 9.0 6.0 9.2 5.5
35 5.5 5.0 6.6 5.5 7.7 6.0 8.2 6.1 8.7 6.2 8.9 5.9 9.0 5.4
37 5.5 5.0 6.6 5.5 7.7 6.0 8.2 6.1 8.5 6.1 8.7 5.8 8.9 5.3
39 5.5 5.0 6.6 5.5 7.7 6.0 8.2 6.1 8.4 6.0 8.5 5.7 8.8 5.3
10 7.2 6.4 8.5 7.1 9.9 7.7 10.6 7.8 11.3 8.1 12.7 8.4 13.9 8.4
12 7.2 6.4 8.5 7.1 9.9 7.7 10.6 7.8 11.3 8.1 12.7 8.4 13.7 8.2
14 7.2 6.4 8.5 7.1 9.9 7.7 10.6 7.8 11.3 8.1 12.7 8.4 13.6 8.2
16 7.2 6.4 8.5 7.1 9.9 7.7 10.6 7.8 11.3 8.1 12.7 8.4 13.4 8.0
18 7.2 6.4 8.5 7.1 9.9 7.7 10.6 7.8 11.3 8.1 12.7 8.4 13.2 7.9
20 7.2 6.4 8.5 7.1 9.9 7.7 10.6 7.8 11.3 8.1 12.7 8.4 13.0 7.8
21 7.2 6.4 8.5 7.1 9.9 7.7 10.6 7.8 11.3 8.1 12.7 8.4 12.9 7.8
23 7.2 6.4 8.5 7.1 9.9 7.7 10.6 7.8 11.3 8.1 12.7 8.4 12.8 7.7
10.6 25 7.2 6.4 8.5 7.1 9.9 7.7 10.6 7.8 11.3 8.1 12.5 8.3 12.6 7.5
27 7.2 6.4 8.5 7.1 9.9 7.7 10.6 7.8 11.3 8.1 12.2 8.1 12.4 7.5
29 7.2 6.4 8.5 7.1 9.9 7.7 10.6 7.8 11.3 8.1 12.1 8.0 12.2 7.3
31 7.2 6.4 8.5 7.1 9.9 7.7 10.6 7.8 11.3 8.1 11.9 7.9 12.0 7.2
33 7.2 6.4 8.5 7.1 9.9 7.7 10.6 7.8 11.3 8.1 11.7 7.8 11.8 7.1
35 7.2 6.4 8.5 7.1 9.9 7.7 10.6 7.8 11.3 8.1 11.4 7.6 11.7 7.0
37 7.2 6.4 8.5 7.1 9.9 7.7 10.6 7.8 11.0 7.9 11.2 7.5 11.5 6.9
39 7.2 6.4 8.5 7.1 9.9 7.7 10.6 7.8 10.8 7.7 11.0 7.3 11.3 6.8
10 8.3 7.5 9.9 8.3 11.5 9.0 12.3 9.1 13.1 9.4 14.7 9.8 16.2 9.7
12 8.3 7.5 9.9 8.3 11.5 9.0 12.3 9.1 13.1 9.4 14.7 9.8 15.9 9.6
14 8.3 7.5 9.9 8.3 11.5 9.0 12.3 9.1 13.1 9.4 14.7 9.8 15.8 9.5
16 8.3 7.5 9.9 8.3 11.5 9.0 12.3 9.1 13.1 9.4 14.7 9.8 15.6 9.3
18 8.3 7.5 9.9 8.3 11.5 9.0 12.3 9.1 13.1 9.4 14.7 9.8 15.3 9.2
20 8.3 7.5 9.9 8.3 11.5 9.0 12.3 9.1 13.1 9.4 14.7 9.8 15.1 9.1
21 8.3 7.5 9.9 8.3 11.5 9.0 12.3 9.1 13.1 9.4 14.7 9.8 15.0 9.0
23 8.3 7.5 9.9 8.3 11.5 9.0 12.3 9.1 13.1 9.4 14.7 9.8 14.8 8.9
12.3 25 8.3 7.5 9.9 8.3 11.5 9.0 12.3 9.1 13.1 9.4 14.5 9.7 14.6 8.8
27 8.3 7.5 9.9 8.3 11.5 9.0 12.3 9.1 13.1 9.4 14.1 9.4 14.4 8.6
29 8.3 7.5 9.9 8.3 11.5 9.0 12.3 9.1 13.1 9.4 14.0 9.3 14.2 8.5
31 8.3 7.5 9.9 8.3 11.5 9.0 12.3 9.1 13.1 9.4 13.8 9.2 14.0 8.4
33 8.3 7.5 9.9 8.3 11.5 9.0 12.3 9.1 13.1 9.4 13.5 9.0 13.7 8.3
35 8.3 7.5 9.9 8.3 11.5 9.0 12.3 9.1 13.1 9.4 13.3 8.8 13.5 8.1
37 8.3 7.5 9.9 8.3 11.5 9.0 12.3 9.1 12.8 9.2 13.0 8.7 13.4 8.0
39 8.3 7.5 9.9 8.3 11.5 9.0 12.3 9.1 12.5 9.0 12.8 8.5 13.1 7.9

18 _ Ceiling Concealed Duct(High Static)


6. Capacity Tables
Cooling capacity

Indoor air temp. (DB/WB, °C)


Capacity Outdoor 20 23 26 27 28 30 32
Index air temp. 14 16 18 19 20 22 24
(DB, °C) TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10 9.5 8.7 11.3 9.6 13.2 10.4 14.1 10.6 15.0 10.9 16.9 11.4 18.5 11.3
12 9.5 8.7 11.3 9.6 13.2 10.4 14.1 10.6 15.0 10.9 16.9 11.4 18.3 11.1
14 9.5 8.7 11.3 9.6 13.2 10.4 14.1 10.6 15.0 10.9 16.9 11.4 18.1 11.0
16 9.5 8.7 11.3 9.6 13.2 10.4 14.1 10.6 15.0 10.9 16.9 11.4 17.8 10.8
18 9.5 8.7 11.3 9.6 13.2 10.4 14.1 10.6 15.0 10.9 16.9 11.4 17.6 10.7
20 9.5 8.7 11.3 9.6 13.2 10.4 14.1 10.6 15.0 10.9 16.9 11.4 17.3 10.5
21 9.5 8.7 11.3 9.6 13.2 10.4 14.1 10.6 15.0 10.9 16.9 11.4 17.2 10.5
23 9.5 8.7 11.3 9.6 13.2 10.4 14.1 10.6 15.0 10.9 16.9 11.4 17.0 10.3
14.1 25 9.5 8.7 11.3 9.6 13.2 10.4 14.1 10.6 15.0 10.9 16.6 11.2 16.7 10.2
27 9.5 8.7 11.3 9.6 13.2 10.4 14.1 10.6 15.0 10.9 16.2 10.9 16.5 10.0
29 9.5 8.7 11.3 9.6 13.2 10.4 14.1 10.6 15.0 10.9 16.1 10.8 16.3 9.9

Indoor Units
31 9.5 8.7 11.3 9.6 13.2 10.4 14.1 10.6 15.0 10.9 15.8 10.7 16.0 9.7
33 9.5 8.7 11.3 9.6 13.2 10.4 14.1 10.6 15.0 10.9 15.5 10.5 15.8 9.6
35 9.5 8.7 11.3 9.6 13.2 10.4 14.1 10.6 15.0 10.9 15.2 10.3 15.5 9.4
37 9.5 8.7 11.3 9.6 13.2 10.4 14.1 10.6 14.7 10.6 14.9 10.1 15.3 9.3
39 9.5 8.7 11.3 9.6 13.2 10.4 14.1 10.6 14.4 10.4 14.7 9.9 15.1 9.2
10 10.7 10.1 12.7 11.1 14.7 12.1 15.8 12.3 16.9 12.8 18.9 13.3 20.7 13.0
12 10.7 10.1 12.7 11.1 14.7 12.1 15.8 12.3 16.9 12.8 18.9 13.3 20.5 13.0
14 10.7 10.1 12.7 11.1 14.7 12.1 15.8 12.3 16.9 12.8 18.9 13.3 20.3 12.8
16 10.7 10.1 12.7 11.1 14.7 12.1 15.8 12.3 16.9 12.8 18.9 13.3 20.0 12.6
18 10.7 10.1 12.7 11.1 14.7 12.1 15.8 12.3 16.9 12.8 18.9 13.3 19.6 12.6
20 10.7 10.1 12.7 11.1 14.7 12.1 15.8 12.3 16.9 12.8 18.9 13.3 19.4 12.3
21 10.7 10.1 12.7 11.1 14.7 12.1 15.8 12.3 16.9 12.8 18.9 13.3 19.4 12.3
23 10.7 10.1 12.7 11.1 14.7 12.1 15.8 12.3 16.9 12.8 18.9 13.3 18.9 12.1
15.8 25 10.7 10.1 12.7 11.1 14.7 12.1 15.8 12.3 16.9 12.8 18.7 13.0 18.7 11.8
27 10.7 10.1 12.7 11.1 14.7 12.1 15.8 12.3 16.9 12.8 18.2 12.8 18.5 11.8
29 10.7 10.1 12.7 11.1 14.7 12.1 15.8 12.3 16.9 12.8 18.0 12.6 18.2 11.6
31 10.7 10.1 12.7 11.1 14.7 12.1 15.8 12.3 16.9 12.8 17.8 12.3 18.0 11.4
33 10.7 10.1 12.7 11.1 14.7 12.1 15.8 12.3 16.9 12.8 17.4 12.3 17.6 11.1
35 10.7 10.1 12.7 11.1 14.7 12.1 15.8 12.3 16.9 12.8 17.1 12.1 17.4 11.1
37 10.7 10.1 12.7 11.1 14.7 12.1 15.8 12.3 16.5 12.3 16.7 11.8 17.1 10.9
39 10.7 10.1 12.7 11.1 14.7 12.1 15.8 12.3 16.0 12.1 16.5 11.6 16.9 10.6
10 15.1 12.9 18.0 14.2 20.8 15.4 22.4 15.7 24.0 16.3 26.8 16.9 29.3 16.6
12 15.1 12.9 18.0 14.2 20.8 15.4 22.4 15.7 24.0 16.3 26.8 16.9 29.0 16.6
14 15.1 12.9 18.0 14.2 20.8 15.4 22.4 15.7 24.0 16.3 26.8 16.9 28.7 16.3
16 15.1 12.9 18.0 14.2 20.8 15.4 22.4 15.7 24.0 16.3 26.8 16.9 28.4 16.0
18 15.1 12.9 18.0 14.2 20.8 15.4 22.4 15.7 24.0 16.3 26.8 16.9 27.8 16.0
20 15.1 12.9 18.0 14.2 20.8 15.4 22.4 15.7 24.0 16.3 26.8 16.9 27.4 15.7
21 15.1 12.9 18.0 14.2 20.8 15.4 22.4 15.7 24.0 16.3 26.8 16.9 27.4 15.7
23 15.1 12.9 18.0 14.2 20.8 15.4 22.4 15.7 24.0 16.3 26.8 16.9 26.8 15.4
22.4 25 15.1 12.9 18.0 14.2 20.8 15.4 22.4 15.7 24.0 16.3 26.5 16.6 26.5 15.1
27 15.1 12.9 18.0 14.2 20.8 15.4 22.4 15.7 24.0 16.3 25.9 16.3 26.2 15.1
29 15.1 12.9 18.0 14.2 20.8 15.4 22.4 15.7 24.0 16.3 25.6 16.0 25.9 14.8
31 15.1 12.9 18.0 14.2 20.8 15.4 22.4 15.7 24.0 16.3 25.2 15.7 25.6 14.5
33 15.1 12.9 18.0 14.2 20.8 15.4 22.4 15.7 24.0 16.3 24.6 15.7 24.9 14.2
35 15.1 12.9 18.0 14.2 20.8 15.4 22.4 15.7 24.0 16.3 24.3 15.4 24.6 14.2
37 15.1 12.9 18.0 14.2 20.8 15.4 22.4 15.7 23.3 15.7 23.7 15.1 24.3 13.9
39 15.1 12.9 18.0 14.2 20.8 15.4 22.4 15.7 22.7 15.4 23.3 14.8 24.0 13.5

Ceiling Concealed Duct(High Static) _ 19


6. Capacity Tables
Cooling capacity

Indoor air temp. (DB/WB, °C)


Capacity Outdoor 20 23 26 27 28 30 32
Index air temp. 14 16 18 19 20 22 24
(DB, °C) TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10 18.9 16.1 22.5 17.7 26.0 19.2 28.0 19.6 30.0 20.4 33.5 21.1 36.7 20.8
12 18.9 16.1 22.5 17.7 26.0 19.2 28.0 19.6 30.0 20.4 33.5 21.1 36.3 20.8
14 18.9 16.1 22.5 17.7 26.0 19.2 28.0 19.6 30.0 20.4 33.5 21.1 35.9 20.4
16 18.9 16.1 22.5 17.7 26.0 19.2 28.0 19.6 30.0 20.4 33.5 21.1 35.5 20.0
18 18.9 16.1 22.5 17.7 26.0 19.2 28.0 19.6 30.0 20.4 33.5 21.1 34.7 20.0
20 18.9 16.1 22.5 17.7 26.0 19.2 28.0 19.6 30.0 20.4 33.5 21.1 34.3 19.6
21 18.9 16.1 22.5 17.7 26.0 19.2 28.0 19.6 30.0 20.4 33.5 21.1 34.3 19.6
23 18.9 16.1 22.5 17.7 26.0 19.2 28.0 19.6 30.0 20.4 33.5 21.1 33.5 19.2
28.0 25 18.9 16.1 22.5 17.7 26.0 19.2 28.0 19.6 30.0 20.4 33.1 20.8 33.1 18.8
27 18.9 16.1 22.5 17.7 26.0 19.2 28.0 19.6 30.0 20.4 32.3 20.4 32.7 18.8
29 18.9 16.1 22.5 17.7 26.0 19.2 28.0 19.6 30.0 20.4 31.9 20.0 32.3 18.4
Indoor Units

31 18.9 16.1 22.5 17.7 26.0 19.2 28.0 19.6 30.0 20.4 31.5 19.6 31.9 18.1
33 18.9 16.1 22.5 17.7 26.0 19.2 28.0 19.6 30.0 20.4 30.8 19.6 31.2 17.7
35 18.9 16.1 22.5 17.7 26.0 19.2 28.0 19.6 30.0 20.4 30.4 19.2 30.8 17.7
37 18.9 16.1 22.5 17.7 26.0 19.2 28.0 19.6 29.2 19.6 29.6 18.8 30.4 17.3
39 18.9 16.1 22.5 17.7 26.0 19.2 28.0 19.6 28.4 19.2 29.2 18.4 30.0 16.9

Notes:
TC: Total Capacity(kW), SHC: Sensible Heat Capacity(kW) 2. Refer to Capacity Correction Factor in the outdoor unit PDB for
1. Capacity tables show the representative value of conditions the actual performance data of each indoor unit and outdoor unit
which may occur. combination.

20 _ Ceiling Concealed Duct(High Static)


6. Capacity Tables
6.2 Heating Capacity Heating capacity

Outdoor air Indoor air temp. (DB, °C)


Capacity temp. 16 18 20 21 22 24
Index TC TC TC TC TC TC
DB(°C) WB(°C)
kW kW kW kW kW kW
-24.8 -25.0 1.4 1.4 1.4 1.4 1.4 1.4
-21.8 -22.0 1.7 1.7 1.7 1.7 1.7 1.7
-19.8 -20.0 1.8 1.8 1.8 1.8 1.8 1.8
-18.8 -19.0 1.9 1.9 1.9 1.9 1.9 1.9
-16.7 -17.0 2.0 2.0 2.0 2.0 2.0 2.0
-14.7 -15.0 2.1 2.1 2.1 2.1 2.1 2.0
-12.6 -13.0 2.2 2.2 2.2 2.2 2.1 2.1
-10.5 -11.0 2.3 2.3 2.2 2.2 2.2 2.2
-9.5 -10.0 2.3 2.3 2.3 2.3 2.3 2.2
-8.5 -9.1 2.3 2.3 2.3 2.3 2.3 2.2
2.2 -7.0 -7.6 2.4 2.4 2.4 2.4 2.3 2.2
-5.0 -5.6 2.5 2.5 2.5 2.4 2.3 2.2
-3.0 -3.7 2.6 2.6 2.5 2.4 2.3 2.2
0.0 -0.7 2.7 2.6 2.5 2.4 2.3 2.2
3.0 2.2 2.7 2.7 2.5 2.4 2.3 2.2

Indoor Units
5.0 4.1 2.8 2.7 2.5 2.4 2.3 2.2
7.0 6.0 2.8 2.7 2.5 2.4 2.3 2.2
9.0 7.9 2.8 2.7 2.5 2.4 2.3 2.2
11.0 9.8 2.8 2.7 2.5 2.4 2.3 2.2
13.0 11.8 2.8 2.7 2.5 2.4 2.3 2.2
15.0 13.7 2.8 2.7 2.5 2.4 2.3 2.2
-24.8 -25.0 1.9 1.9 1.8 1.8 1.8 1.8
-21.8 -22.0 2.2 2.2 2.2 2.2 2.2 2.2
-19.8 -20.0 2.4 2.4 2.3 2.3 2.3 2.3
-18.8 -19.0 2.4 2.4 2.4 2.4 2.4 2.4
-16.7 -17.0 2.5 2.5 2.5 2.5 2.5 2.5
-14.7 -15.0 2.7 2.7 2.6 2.6 2.6 2.6
-12.6 -13.0 2.8 2.8 2.8 2.8 2.7 2.7
-10.5 -11.0 2.9 2.9 2.9 2.9 2.9 2.8
-9.5 -10.0 3.0 3.0 2.9 2.9 2.9 2.8
-8.5 -9.1 3.0 3.0 3.0 3.0 3.0 2.8
2.8 -7.0 -7.6 3.1 3.1 3.1 3.1 3.0 2.8
-5.0 -5.6 3.2 3.2 3.2 3.1 3.0 2.8
-3.0 -3.7 3.4 3.3 3.2 3.1 3.0 2.8
0.0 -0.7 3.4 3.3 3.2 3.1 3.0 2.8
3.0 2.2 3.5 3.4 3.2 3.1 3.0 2.8
5.0 4.1 3.6 3.4 3.2 3.1 3.0 2.8
7.0 6.0 3.6 3.4 3.2 3.1 3.0 2.8
9.0 7.9 3.6 3.4 3.2 3.1 3.0 2.8
11.0 9.8 3.6 3.4 3.2 3.1 3.0 2.8
13.0 11.8 3.6 3.4 3.2 3.1 3.0 2.8
15.0 13.7 3.6 3.4 3.2 3.1 3.0 2.8
-24.8 -25.0 2.3 2.3 2.3 2.3 2.3 2.3
-21.8 -22.0 2.8 2.8 2.8 2.8 2.8 2.8
-19.8 -20.0 2.9 2.9 2.9 2.9 2.9 2.9
-18.8 -19.0 3.0 3.0 3.0 3.0 3.0 3.0
-16.7 -17.0 3.1 3.1 3.1 3.1 3.1 3.1
-14.7 -15.0 3.3 3.3 3.3 3.3 3.3 3.3
-12.6 -13.0 3.5 3.4 3.4 3.4 3.4 3.4
-10.5 -11.0 3.6 3.6 3.6 3.6 3.6 3.5
-9.5 -10.0 3.7 3.7 3.7 3.7 3.7 3.5
-8.5 -9.1 3.8 3.8 3.7 3.7 3.7 3.5
-7.0 -7.6 3.9 3.9 3.9 3.8 3.7 3.5
3.6 -5.0 -5.6 4.0 4.0 4.0 3.9 3.7 3.5
-3.0 -3.7 4.2 4.1 4.0 3.9 3.7 3.5
0.0 -0.7 4.3 4.1 4.0 3.9 3.7 3.5
3.0 2.2 4.4 4.3 4.0 3.9 3.7 3.5
5.0 4.1 4.5 4.3 4.0 3.9 3.7 3.5
7.0 6.0 4.5 4.3 4.0 3.9 3.7 3.5
9.0 7.9 4.5 4.3 4.0 3.9 3.7 3.5
11.0 9.8 4.5 4.3 4.0 3.9 3.7 3.5
13.0 11.8 4.5 4.3 4.0 3.9 3.7 3.5
15.0 13.7 4.5 4.3 4.0 3.9 3.7 3.5

Ceiling Concealed Duct(High Static) _ 21


6. Capacity Tables
Heating capacity

Outdoor air Indoor air temp. (DB, °C)


Capacity temp. 16 18 20 21 22 24
Index TC TC TC TC TC TC
DB(°C) WB(°C)
kW kW kW kW kW kW
-24.8 -25.0 2.9 2.9 2.9 2.9 2.9 2.9
-21.8 -22.0 3.5 3.5 3.5 3.5 3.5 3.5
-19.8 -20.0 3.7 3.7 3.7 3.7 3.7 3.6
-18.8 -19.0 3.8 3.7 3.7 3.7 3.7 3.7
-16.7 -17.0 3.9 3.9 3.9 3.9 3.9 3.9
-14.7 -15.0 4.1 4.1 4.1 4.1 4.1 4.1
-12.6 -13.0 4.3 4.3 4.3 4.3 4.3 4.3
-10.5 -11.0 4.5 4.5 4.5 4.5 4.5 4.4
-9.5 -10.0 4.6 4.6 4.6 4.6 4.6 4.4
-8.5 -9.1 4.7 4.7 4.7 4.7 4.7 4.4
-7.0 -7.6 4.8 4.8 4.8 4.8 4.7 4.4
4.5 -5.0 -5.6 5.0 5.0 5.0 4.8 4.7 4.4
-3.0 -3.7 5.3 5.1 5.0 4.8 4.7 4.4
0.0 -0.7 5.3 5.2 5.0 4.8 4.7 4.4
3.0 2.2 5.5 5.3 5.0 4.8 4.7 4.4
Indoor Units

5.0 4.1 5.6 5.3 5.0 4.8 4.7 4.4


7.0 6.0 5.6 5.3 5.0 4.8 4.7 4.4
9.0 7.9 5.6 5.3 5.0 4.8 4.7 4.4
11.0 9.8 5.6 5.3 5.0 4.8 4.7 4.4
13.0 11.8 5.6 5.3 5.0 4.8 4.7 4.4
15.0 13.7 5.6 5.3 5.0 4.8 4.7 4.4
-24.8 -25.0 3.6 3.6 3.6 3.6 3.6 3.6
-21.8 -22.0 4.4 4.4 4.4 4.4 4.4 4.4
-19.8 -20.0 4.6 4.6 4.6 4.6 4.6 4.6
-18.8 -19.0 4.8 4.7 4.7 4.7 4.7 4.7
-16.7 -17.0 5.0 5.0 5.0 4.9 4.9 4.9
-14.7 -15.0 5.2 5.2 5.2 5.2 5.2 5.2
-12.6 -13.0 5.5 5.4 5.4 5.4 5.4 5.4
-10.5 -11.0 5.7 5.7 5.7 5.7 5.7 5.5
-9.5 -10.0 5.8 5.8 5.8 5.8 5.8 5.5
-8.5 -9.1 5.9 5.9 5.9 5.9 5.9 5.5
5.6 -7.0 -7.6 6.1 6.1 6.1 6.0 5.9 5.5
-5.0 -5.6 6.3 6.3 6.3 6.1 5.9 5.5
-3.0 -3.7 6.6 6.5 6.3 6.1 5.9 5.5
0.0 -0.7 6.7 6.5 6.3 6.1 5.9 5.5
3.0 2.2 6.9 6.7 6.3 6.1 5.9 5.5
5.0 4.1 7.0 6.7 6.3 6.1 5.9 5.5
7.0 6.0 7.1 6.7 6.3 6.1 5.9 5.5
9.0 7.9 7.1 6.7 6.3 6.1 5.9 5.5
11.0 9.8 7.1 6.7 6.3 6.1 5.9 5.5
13.0 11.8 7.1 6.7 6.3 6.1 5.9 5.5
15.0 13.7 7.1 6.7 6.3 6.1 5.9 5.5
-24.8 -25.0 4.6 4.6 4.6 4.6 4.6 4.6
-21.8 -22.0 5.6 5.6 5.6 5.6 5.6 5.5
-19.8 -20.0 5.9 5.9 5.9 5.9 5.9 5.8
-18.8 -19.0 6.0 6.0 6.0 6.0 6.0 6.0
-16.7 -17.0 6.3 6.3 6.3 6.3 6.3 6.3
-14.7 -15.0 6.6 6.6 6.6 6.6 6.6 6.6
-12.6 -13.0 6.9 6.9 6.9 6.9 6.9 6.9
-10.5 -11.0 7.2 7.2 7.2 7.2 7.2 7.0
-9.5 -10.0 7.4 7.4 7.3 7.3 7.3 7.0
-8.5 -9.1 7.5 7.5 7.5 7.5 7.5 7.0
-7.0 -7.6 7.7 7.7 7.7 7.7 7.5 7.0
7.1 -5.0 -5.6 8.0 8.0 8.0 7.7 7.5 7.0
-3.0 -3.7 8.4 8.2 8.0 7.7 7.5 7.0
0.0 -0.7 8.6 8.3 8.0 7.7 7.5 7.0
3.0 2.2 8.8 8.5 8.0 7.7 7.5 7.0
5.0 4.1 8.9 8.5 8.0 7.7 7.5 7.0
7.0 6.0 9.0 8.5 8.0 7.7 7.5 7.0
9.0 7.9 9.0 8.5 8.0 7.7 7.5 7.0
11.0 9.8 9.0 8.5 8.0 7.7 7.5 7.0
13.0 11.8 9.0 8.5 8.0 7.7 7.5 7.0
15.0 13.7 9.0 8.5 8.0 7.7 7.5 7.0

22 _ Ceiling Concealed Duct(High Static)


6. Capacity Tables
Heating capacity

Outdoor air Indoor air temp. (DB, °C)


Capacity temp. 16 18 20 21 22 24
Index TC TC TC TC TC TC
DB(°C) WB(°C)
kW kW kW kW kW kW
-24.8 -25.0 5.3 5.3 5.3 5.3 5.3 5.3
-21.8 -22.0 6.4 6.4 6.4 6.4 6.4 6.4
-19.8 -20.0 6.8 6.8 6.7 6.7 6.7 6.7
-18.8 -19.0 6.9 6.9 6.9 6.9 6.9 6.9
-16.7 -17.0 7.2 6.9 7.2 7.2 7.2 7.2
-14.7 -15.0 7.6 6.9 7.6 7.6 7.6 7.5
-12.6 -13.0 8.0 6.9 7.9 7.9 7.9 7.9
-10.5 -11.0 8.3 6.9 8.3 8.3 8.3 8.0
-9.5 -10.0 8.5 6.9 8.4 8.4 8.4 8.0
-8.5 -9.1 8.6 6.9 8.6 8.6 8.6 8.0
-7.0 -7.6 8.9 6.9 8.9 8.8 8.6 8.0
8.2 -5.0 -5.6 9.2 6.9 9.2 8.9 8.6 8.0
-3.0 -3.7 9.7 6.9 9.2 8.9 8.6 8.0
0.0 -0.7 9.8 6.9 9.2 8.9 8.6 8.0
3.0 2.2 10.1 6.9 9.2 8.9 8.6 8.0

Indoor Units
5.0 4.1 10.3 6.9 9.2 8.9 8.6 8.0
7.0 6.0 10.4 6.9 9.2 8.9 8.6 8.0
9.0 7.9 10.4 6.9 9.2 8.9 8.6 8.0
11.0 9.8 10.4 6.9 9.2 8.9 8.6 8.0
13.0 11.8 10.4 6.9 9.2 8.9 8.6 8.0
15.0 13.7 10.4 6.9 9.2 8.9 8.6 8.0
-24.8 -25.0 6.9 6.9 6.8 6.8 6.8 6.8
-21.8 -22.0 8.3 8.3 8.3 8.3 8.3 8.2
-19.8 -20.0 8.8 8.8 8.7 8.7 8.7 8.6
-18.8 -19.0 9.0 8.9 8.9 8.9 8.9 8.9
-16.7 -17.0 9.4 9.4 9.4 9.3 9.3 9.3
-14.7 -15.0 9.9 9.9 9.8 9.8 9.8 9.8
-12.6 -13.0 10.3 10.3 10.3 10.3 10.2 10.2
-10.5 -11.0 10.8 10.8 10.7 10.7 10.7 10.4
-9.5 -10.0 11.0 11.0 10.9 10.9 10.9 10.4
-8.5 -9.1 11.2 11.2 11.1 11.1 11.1 10.4
10.6 -7.0 -7.6 11.5 11.5 11.5 11.4 11.1 10.4
-5.0 -5.6 12.0 11.9 11.9 11.5 11.1 10.4
-3.0 -3.7 12.5 12.2 11.9 11.5 11.1 10.4
0.0 -0.7 12.7 12.3 11.9 11.5 11.1 10.4
3.0 2.2 13.1 12.7 11.9 11.5 11.1 10.4
5.0 4.1 13.3 12.7 11.9 11.5 11.1 10.4
7.0 6.0 13.4 12.7 11.9 11.5 11.1 10.4
9.0 7.9 13.4 12.7 11.9 11.5 11.1 10.4
11.0 9.8 13.4 12.7 11.9 11.5 11.1 10.4
13.0 11.8 13.4 12.7 11.9 11.5 11.1 10.4
15.0 13.7 13.4 12.7 11.9 11.5 11.1 10.4
-24.8 -25.0 8.0 8.0 7.9 7.9 7.9 7.9
-21.8 -22.0 9.7 9.7 9.6 9.6 9.6 9.5
-19.8 -20.0 10.2 10.2 10.1 10.1 10.1 10.0
-18.8 -19.0 10.4 10.3 10.3 10.3 10.3 10.3
-16.7 -17.0 10.9 10.9 10.9 10.8 10.8 10.8
-14.7 -15.0 11.4 11.4 11.4 11.4 11.4 11.3
-12.6 -13.0 12.0 11.9 11.9 11.9 11.8 11.8
-10.5 -11.0 12.5 12.5 12.4 12.4 12.4 12.0
-9.5 -10.0 12.7 12.7 12.7 12.7 12.7 12.0
-8.5 -9.1 13.0 13.0 12.9 12.9 12.9 12.0
-7.0 -7.6 13.3 13.3 13.3 13.2 12.9 12.0
12.3 -5.0 -5.6 13.9 13.8 13.8 13.4 12.9 12.0
-3.0 -3.7 14.5 14.2 13.8 13.4 12.9 12.0
0.0 -0.7 14.8 14.3 13.8 13.4 12.9 12.0
3.0 2.2 15.2 14.7 13.8 13.4 12.9 12.0
5.0 4.1 15.4 14.7 13.8 13.4 12.9 12.0
7.0 6.0 15.6 14.7 13.8 13.4 12.9 12.0
9.0 7.9 15.6 14.7 13.8 13.4 12.9 12.0
11.0 9.8 15.6 14.7 13.8 13.4 12.9 12.0
13.0 11.8 15.6 14.7 13.8 13.4 12.9 12.0
15.0 13.7 15.6 14.7 13.8 13.4 12.9 12.0

Ceiling Concealed Duct(High Static) _ 23


6. Capacity Tables
Heating capacity

Outdoor air Indoor air temp. (DB, °C)


Capacity temp. 16 18 20 21 22 24
Index TC TC TC TC TC TC
DB(°C) WB(°C)
kW kW kW kW kW kW
-24.8 -25.0 9.2 9.2 9.1 9.1 9.1 9.1
-21.8 -22.0 11.1 11.1 11.1 11.1 11.1 11.0
-19.8 -20.0 11.7 11.7 11.6 11.6 11.6 11.6
-18.8 -19.0 12.0 11.9 11.9 11.9 11.9 11.9
-16.7 -17.0 12.5 12.5 12.5 12.4 12.4 12.4
-14.7 -15.0 13.2 13.2 13.1 13.1 13.1 13.0
-12.6 -13.0 13.8 13.7 13.7 13.7 13.6 13.6
-10.5 -11.0 14.4 14.4 14.3 14.3 14.3 13.9
-9.5 -10.0 14.7 14.7 14.6 14.6 14.6 13.9
-8.5 -9.1 14.9 14.9 14.9 14.9 14.9 13.9
-7.0 -7.6 15.4 15.3 15.3 15.2 14.9 13.9
14.1 -5.0 -5.6 16.0 15.9 15.9 15.4 14.9 13.9
-3.0 -3.7 16.7 16.3 15.9 15.4 14.9 13.9
0.0 -0.7 17.0 16.5 15.9 15.4 14.9 13.9
3.0 2.2 17.5 16.9 15.9 15.4 14.9 13.9
Indoor Units

5.0 4.1 17.7 16.9 15.9 15.4 14.9 13.9


7.0 6.0 17.9 16.9 15.9 15.4 14.9 13.9
9.0 7.9 17.9 16.9 15.9 15.4 14.9 13.9
11.0 9.8 17.9 16.9 15.9 15.4 14.9 13.9
13.0 11.8 17.9 16.9 15.9 15.4 14.9 13.9
15.0 13.7 17.9 16.9 15.9 15.4 14.9 13.9
-24.8 -25.0 10.4 10.4 10.4 10.4 10.4 10.3
-21.8 -22.0 12.6 12.6 12.5 12.5 12.5 12.4
-19.8 -20.0 13.2 13.2 13.2 13.2 13.2 13.1
-18.8 -19.0 13.6 13.5 13.5 13.5 13.4 13.4
-16.7 -17.0 14.2 14.2 14.2 14.1 14.1 14.1
-14.7 -15.0 14.9 14.9 14.8 14.8 14.8 14.8
-12.6 -13.0 15.6 15.5 15.5 15.5 15.4 15.4
-10.5 -11.0 16.3 16.3 16.2 16.2 16.2 15.7
-9.5 -10.0 16.6 16.6 16.5 16.5 16.5 15.7
-8.5 -9.1 16.9 16.9 16.8 16.8 16.8 15.7
15.8 -7.0 -7.6 17.4 17.3 17.3 17.3 16.8 15.7
-5.0 -5.6 18.1 18.0 18.0 17.4 16.8 15.7
-3.0 -3.7 18.9 18.5 18.0 17.4 16.8 15.7
0.0 -0.7 19.3 18.6 18.0 17.4 16.8 15.7
3.0 2.2 19.8 19.2 18.0 17.4 16.8 15.7
5.0 4.1 20.1 19.2 18.0 17.4 16.8 15.7
7.0 6.0 20.3 19.2 18.0 17.4 16.8 15.7
9.0 7.9 20.3 19.2 18.0 17.4 16.8 15.7
11.0 9.8 20.3 19.2 18.0 17.4 16.8 15.7
13.0 11.8 20.3 19.2 18.0 17.4 16.8 15.7
15.0 13.7 20.3 19.2 18.0 17.4 16.8 15.7
-24.8 -25.0 14.6 14.6 14.5 14.5 14.5 14.4
-21.8 -22.0 17.6 17.6 17.5 17.5 17.5 17.4
-19.8 -20.0 18.5 18.5 18.4 18.4 18.4 18.3
-18.8 -19.0 19.0 18.9 18.9 18.9 18.8 18.8
-16.7 -17.0 19.8 19.8 19.8 19.7 19.7 19.7
-14.7 -15.0 20.9 20.9 20.8 20.8 20.8 20.7
-12.6 -13.0 21.8 21.7 21.7 21.7 21.6 21.6
-10.5 -11.0 22.8 22.8 22.7 22.7 22.7 22.0
-9.5 -10.0 23.2 23.2 23.1 23.1 23.1 22.0
-8.5 -9.1 23.7 23.7 23.6 23.6 23.6 22.0
-7.0 -7.6 24.4 24.3 24.3 24.2 23.6 22.0
22.4 -5.0 -5.6 25.3 25.3 25.2 24.4 23.6 22.0
-3.0 -3.7 26.5 25.8 25.2 24.4 23.6 22.0
0.0 -0.7 27.0 26.1 25.2 24.4 23.6 22.0
3.0 2.2 27.7 26.8 25.2 24.4 23.6 22.0
5.0 4.1 28.1 26.8 25.2 24.4 23.6 22.0
7.0 6.0 28.4 26.8 25.2 24.4 23.6 22.0
9.0 7.9 28.4 26.8 25.2 24.4 23.6 22.0
11.0 9.8 28.4 26.8 25.2 24.4 23.6 22.0
13.0 11.8 28.4 26.8 25.2 24.4 23.6 22.0
15.0 13.7 28.4 26.8 25.2 24.4 23.6 22.0

24 _ Ceiling Concealed Duct(High Static)


6. Capacity Tables
Heating capacity

Outdoor air Indoor air temp. (DB, °C)


Capacity temp. 16 18 20 21 22 24
Index TC TC TC TC TC TC
DB(°C) WB(°C)
kW kW kW kW kW kW
-24.8 -25.0 18.2 18.2 18.1 18.1 18.1 18.0
-21.8 -22.0 22.0 22.0 21.9 21.9 21.9 21.8
-19.8 -20.0 23.2 23.2 23.0 23.0 23.0 22.9
-18.8 -19.0 23.8 23.6 23.6 23.6 23.5 23.5
-16.7 -17.0 24.8 24.8 24.8 24.7 24.7 24.7
-14.7 -15.0 26.1 26.1 26.0 26.0 26.0 25.8
-12.6 -13.0 27.3 27.1 27.1 27.1 27.0 27.0
-10.5 -11.0 28.5 28.5 28.3 28.3 28.3 27.5
-9.5 -10.0 29.1 29.1 28.9 28.9 28.9 27.5
-8.5 -9.1 29.6 29.6 29.4 29.4 29.4 27.5
-7.0 -7.6 30.5 30.3 30.3 30.2 29.5 27.5
28.0 -5.0 -5.6 31.6 31.6 31.5 30.5 29.5 27.5
-3.0 -3.7 33.1 32.3 31.5 30.5 29.5 27.5
0.0 -0.7 33.7 32.6 31.5 30.5 29.5 27.5
3.0 2.2 34.6 33.5 31.5 30.5 29.5 27.5

Indoor Units
5.0 4.1 35.2 33.5 31.5 30.5 29.5 27.5
7.0 6.0 35.5 33.5 31.5 30.5 29.5 27.5
9.0 7.9 35.5 33.5 31.5 30.5 29.5 27.5
11.0 9.8 35.5 33.5 31.5 30.5 29.5 27.5
13.0 11.8 35.5 33.5 31.5 30.5 29.5 27.5
15.0 13.7 35.5 33.5 31.5 30.5 29.5 27.5

Notes:
TC: Total Capacity(kW) 3. In accordance with operation limits of outdoor unit, applicable range of
1. Capacity tables show the representative value of conditions which may occur. capacity tables is different.
2. is shown as reference. When selecting the outdoor units, avoid the 4. Refer to Capacity Correction Factor in the outdoor unit PDB for the actual
outdoor air temperature range shown by . performance data of each indoor unit and outdoor unit combination.

Ceiling Concealed Duct(High Static) _ 25


7. External Static Pressure (E.S.P) & Air Flow
ARNU07GBHA2, ARNU09GBHA2, ARNU12GBHA2
ARNU15GBHA2, ARNU18GBHA2, ARNU24GBHA2 (Unit: CMM)

Static Pressure(mmAq(Pa))
Setting Value
3(29) 4(39) 5(49) 6(59) 7(69) 8(78) 9(88) 10(98) 12(118)
70 2.7 - - - - - - - -
80 5.3 - - - - - - - -
90 7.8 6.1 3.6 2.9 - - - - -
100 10.2 8.1 6.0 3.8 3.3 - - - -
110 12.6 11.6 8.8 7.3 5.9 4.2 - - -
120 15.7 14.2 11.9 10.1 8.4 6.5 5.0 4.4 -
130 17.9 16.5 15.5 13.2 11.8 9.6 7.6 6.1 4.3
140 20.5 19.0 17.6 16.1 15.3 13.0 12.1 10.3 5.8
145 21.4 19.9 19.3 17.5 16.1 14.4 13.6 11.1 7.9
150 22.5 21.3 19.9 18.9 17.6 16.0 14.3 13.9 10.3
Indoor Units

ARNU28GBGA2, ARNU36GBGA2, ARNU42GBGA2 (Unit: CMM)


Static Pressure(mmAq(Pa))
Setting Value
5(49) 6(59) 7(69) 8(78) 9(88) 10(98) 12(118) 14(137) 16(157)
70 - - - - - - - - -
80 4.0 - - - - - - - -
90 12.1 9.3 4.1 - - - - - -
100 17.0 13.5 11.0 6.2 4.2 - - - -
110 21.4 18.6 17.5 14.0 11.6 6.6 - - -
120 25.6 24.0 21.8 19.8 17.9 14.6 12.1 - -
130 30.0 28.5 26.9 25.3 23.4 21.8 18.1 14.6 11.3
140 35.0 32.1 30.4 29.0 27.4 25.9 21.6 17.8 14.5
143 36.1 33.9 32.1 30.7 28.8 27.2 23.0 20.1 16.8
150 38.5 38.0 36.0 34.5 32.1 30.1 26.3 22.4 18.2
160 - - 38.2 36.1 35.0 34.6 31.1 26.8 23.3

ARNU48GBRA2, ARNU54GBRA2 (Unit: CMM)


Static Pressure(mmAq(Pa))
Setting Value
5(49) 6(59) 8(78) 10(98) 12(118) 14(137) 15(147) 16(157) 17(168) 18(176) 20(196)
91 46.5 43.7 38.2 31.3 23.2 14.0 9.0 3.7 - - -
96 49.9 46.1 43.0 33.5 31.1 18.4 13.7 9.0 2.6 - -
101 52.1 50.2 47.9 39.5 37.4 27.3 25.2 17.8 8.9 6.1 -
106 51.4 51.2 50.4 44.4 43.1 33.3 32.1 28.9 21.0 17.9 8.3
111 53.6 53.7 52.9 49.9 48.3 40.6 40.2 32.8 31.5 27.2 17.5
116 - - - 55.7 50.8 44.8 42.6 40.1 37.6 32.5 27.6
121 - - - - 52.2 50.8 50.3 45.7 44.6 38.8 32.2
126 - - - - - - 54.4 51.2 50.4 46.0 43.5

Note: 1. The above table shows the correlation between the air rates and E.S.P.
2. The above table shows the available E.S.P. range.
3. If the E.S.P. of the installed indoor is less than the lowest value(as mention in the table), indoor components
can be failed.

26 _ Ceiling Concealed Duct(High Static)


7. External Static Pressure (E.S.P) & Air Flow
ARNU76GB8A2, ARNU96GB8A2
(Unit: CMM)

Static Pressure(mmAq(Pa))
Setting Value
6(59) 9(88) 12(118) 15(147) 18(177) 20(196) 22(216) 23(226) 25(245)
60 40.5 - - - - - - - -
65 52.7 - - - - - - - -
70 63.7 47.1 - - - - - - -
75 71.1 56.9 44.7 - - - - - -
80 76.3 69.7 55.2 - - - - - -
85 83.3 78.6 67.4 55.9 - - - - -
91 89.7 87.1 78.9 67.6 54.2 - - - -
95 - - 86.1 77.0 66.4 50.6 30.0 - -

Indoor Units
100 - - 88.3 84.9 75.9 69.5 60.8 43.1 -
105 - - 88.3 84.9 81.1 77.4 69.2 67.9 51.3

Note:
1. The above table shows the correlation between the air rates and E.S.P.
2. The above table shows the available E.S.P. range.
3. If the E.S.P. of the installed indoor is less than the lowest value(as mention in the table), indoor components
can be failed.

Ceiling Concealed Duct(High Static) _ 27


7. External Static Pressure (E.S.P) & Air Flow
ARNU07GBHA2, ARNU09GBHA2, ARNU12GBHA2
ARNU15GBHA2, ARNU18GBHA2, ARNU24GBHA2
Standard Lower Limit of External Upper Limit of External
Capacity Mode Set value ESP(mmAq(Pa)) CMM Static Pressure(mmAq(Pa)) Static Pressure(mmAq(Pa))
High Hl 120 6.5
Mid 117 8(78) 5.8 6(59) 12(118)
(factory set) Low 115 5.4
7k 7.3
Hl 110
Standard Mid 107 6(59) 6.3 4(39) 8(78)
Low 105 5.6
High Hl 125 8.1
Mid 120 8(78) 6.5 6(59) 12(118)
(factory set) Low 117 5.8
9k Hl 110 7.3
Standard Mid 107 6(59) 6.3 4(39) 8(78)
Low 105 5.6
Hl 130 9.6
High Mid 125 8(78) 8.1 6(59) 12(118)
(factory set) Low 120 6.5
Indoor Units

12k Hl 115 8.7


Standard Mid 110 6(59) 7.3 4(39) 8(78)
Low 105 5.6
High Hl 135 11.3
Mid 130 8(78) 9.6 6(59) 12(118)
(factory set)
Low 120 6.5
15k 11.0
Hl 123
Standard Mid 120 6(59) 10.1 4(39) 8(78)
Low 115 8.7
High HI 140 13.0
Mid 135 8(78) 11.3 6(59) 12(118)
(factory set)
Low 130 9.6
18k
HI 130 13.2
Standard Mid 125 6(59) 11.7 4(39) 8(78)
Low 110 7.3
High HI 150 16.0
Mid 145 8(78) 14.4 6(59) 12(118)
(factory set) Low 140 13.0
24k
HI 145 17.5
Standard Mid 135 6(59) 14.7 4(39) 8(78)
Low 128 12.6

Note:
The above table shows the available E.S.P. range.

28 _ Ceiling Concealed Duct(High Static)


7. External Static Pressure (E.S.P) & Air Flow
ARNU28GBGA2, ARNU36GBGA2, ARNU42GBGA2
Standard Lower Limit of External Upper Limit of External
Capacity Mode Set value ESP(mmAq(Pa)) CMM Static Pressure(mmAq(Pa)) Static Pressure(mmAq(Pa))

High HI 127 18.7


Mid 120 10(98) 14.6 8(78) 16(157)
(factory set) Low 113 9.1
28k
HI 113 15.9
Standard Mid 102 8(78) 8.6 5(49) 10(98)
Low 97 5.1
High HI 151 30.7
Mid 145 10(98) 29.0 8(78) 14(137)
(factory set) Low 139 25.3
36k
HI 138 28.4
Standard Mid 130 8(78) 25.3 5(49) 10(98)
Low 124 21.8
High HI 157 34.5
Mid 154 10(98) 32.3 8(78) 12(118)
(factory set) Low 151 30.7
42k HI 145 32.0
Standard Mid 138 8(78) 28.4 5(49) 10(98)

Indoor Units
Low 134 27.2

ARNU48GBRA2, ARNU54GBRA2
Capacity Mode Standard
Set value ESP(mmAq(Pa)) Lower Limit of External Upper Limit of External
CMM Static Pressure(mmAq(Pa)) Static Pressure(mmAq(Pa))
High HI 116 44.8
Mid 111 14(137) 40.6 10(98) 20(196)
(factory set) 33.3
Low 106
48k 44.4
HI 106
Standard Mid 102 10(98) 39.5 5(49) 14(137)
Low 95 33.5
High HI 121 51.0
Mid 116 14(137) 44.8 10(98) 20(196)
(factory set) 40.6
Low 111
54k 51.5
HI 112
Standard Mid 108 10(98) 47.5 5(49) 14(137)
Low 102 39.5

ARNU76GB8A2, ARNU96GB8A2
Standard Lower Limit of External Upper Limit of External
Capacity Mode Set value ESP(mmAq(Pa)) CMM
Static Pressure(mmAq(Pa)) Static Pressure(mmAq(Pa))
High HI 102 60.0
Mid 98 22(216) 50.0 12(118) 25(245)
(factory set)
76k Low 98 50.0
HI 86 64.0
Standard Mid 83 15(147) 50.0 12(118) 25(245)
Low 83 50.0
High HI 105 72.0
Mid 102 22(216) 64.0 12(118) 25(245)
(factory set) Low 102 64.0
96k
HI 94 76.0
Standard Mid 89 15(147) 64.0 12(118) 25(245)
Low 89 64.0
Note:
The above table shows the available E.S.P. range.

Ceiling Concealed Duct(High Static) _ 29


8. Electric Characteristics
Units Power Supply IFM Input(W)
Model Type Hz Volts Voltage Range MCA MFA kW FLA Cooling Heating
ARNU07GBHA2 BH 1.32 15 0.118 1.06 150 150
ARNU09GBHA2 BH 1.32 15 0.118 1.06 150 150
ARNU12GBHA2 BH 1.32 15 0.118 1.06 150 150
ARNU15GBHA2 BH 1.32 15 0.118 1.06 150 150
ARNU18GBHA2 BH 1.32 15 0.118 1.06 150 150
ARNU24GBHA2 BH Max:264 1.32 15 0.118 1.06 150 150
50 220-240
ARNU28GBGA2 BG Min:198 3.31 15 0.35 2.65 450 450
ARNU36GBGA2 BG 3.31 15 0.35 2.65 450 450
ARNU42GBGA2 BG 3.31 15 0.35 2.65 450 450
ARNU48GBRA2 BR 3.45 15 0.37 2.76 450 450
Indoor Units

ARNU54GBRA2 BR 3.45 15 0.37 2.76 450 450


ARNU76GB8A2 B8 6.47 15 0.75 5.18 800 800
ARNU96GB8A2 B8 6.47 15 0.75 5.18 800 800
ARNU07GBHA2 BH 1.32 15 0.118 1.06 150 150
ARNU09GBHA2 BH 1.32 15 0.118 1.06 150 150
ARNU12GBHA2 BH 1.32 15 0.118 1.06 150 150
ARNU15GBHA2 BH 1.32 15 0.118 1.06 150 150
ARNU18GBHA2 BH 1.32 15 0.118 1.06 150 150
ARNU24GBHA2 BH Max:242 1.32 15 0.118 1.06 150 150
60 220
ARNU28GBGA2 BG Min:198 3.31 15 0.35 2.65 450 450
ARNU36GBGA2 BG 3.31 15 0.35 2.65 450 450
ARNU42GBGA2 BG 3.31 15 0.35 2.65 450 450
ARNU48GBRA2 BR 3.45 15 0.37 2.76 450 450
ARNU54GBRA2 BR 3.45 15 0.37 2.76 450 450
ARNU76GB8A2 B8 6.47 15 0.75 5.18 800 800
ARNU96GB8A2 B8 6.47 15 0.75 5.18 800 800
Symbols: Note :
MCA : Min, Circuit Amps(A) 1. Voltage range
MFA : Max. Fuse Amps(see note 5) Units are suitable for use on electrical systems where voltage sup-
kW : Fan Motor Rated Output(kW) plied to unit terminals is not below or above the listed range limits,
FLA : Full Load Amps(A) 2. Maximum allowable voltage unbalance between phases is 2%
IFM : Indoor Fan Motor 3. MCA/MFA
MCA=1.25 x FLA
MFA≤ 4 x FLA
(Next lower standard fuse rating. Min. 15A)
4. Select wire size based on the MCA
5. Instead of fuse, use Circuit Breaker.

30 _ Ceiling Concealed Duct(High Static)


9. Sound Levels
Overall
Notes:
DISCHARGE SUCTION 1. Sound measured at 1.5m away from the center of the unit
2. Operating condition
DUCT - Power source : 220-240V 50Hz / 220V 60Hz
DUCT
- Cooling : Indoor temperature (27°C DB, 19°C WB),
Outdoor temperature (35°C DB, 24°C WB)
- Heating : Indoor temperature (20°C DB, 15°C WB),
2m 1.5m
2m Outdoor temperature (7°C DB, 6°C WB)
3. Reference accoustic pressure 0dB = 20μPa
4. Sound level will vary depending on a range of factors such as
the construction(acoustic absorption coefficient) of particular
room in which the equipment in installed.
❈ Measuring place : Anechoic chamber

Sound Pressure Levels (dB(A),H-M-L)


Model External Static Pressure (Pa)
35 50 70 100 120

Indoor Units
ARNU07GBHA2 23 (High) 26-25-23 28-27-27 32-30-30 34-33-33
ARNU09GBHA2 23 (High) 26-25-23 28-27-27 32-30-30 34-33-33
ARNU12GBHA2 24-23-22 27-26-23 30-28-27 34-31-30 35-34-33
ARNU15GBHA2 27-26-24 28-27-25 32-31-28 34-33-31 36-35-34
ARNU18GBHA2 29-28-23 30-29-26 32-32-28 35-34-31 37-36-34
ARNU24GBHA2 32-30-27 33-31-28 34-33-31 36-35-33 38-36-34

Sound Pressure Level (35Pa)


ARNU07GBHA2 ARNU09GBHA2 ARNU12GBHA2 ARNU15GBHA2
80 80 80

n High n High n High


▲ Mid ▲ Mid
70 70 l Low 70 l Low
Octave Band Sound Pressure Level (0 dB = 20 μPa)

Octave Band Sound Pressure Level (0 dB = 20 μPa)

Octave Band Sound Pressure Level (0 dB = 20 μPa)

NC-65 NC-65 NC-65


60 60 60
NC-60 NC-60 NC-60

NC-55 NC-55 NC-55


50 50 50
NC-50 NC-50 NC-50

NC-45 NC-45 NC-45


40 40 40
NC-40 NC-40 NC-40

NC-35 NC-35 NC-35


30 30 30
NC-30 NC-30 NC-30

NC-25 NC-25 NC-25


20 20 20
Approximate Approximate Approximate
NC-20 NC-20 NC-20
Hearing Hearing Hearing
Threshold Threshold Threshold
NC-15 NC-15 NC-15
10 10 10
63 125 250 500 1 000 2 000 4 000 8 000 63 125 250 500 1 000 2 000 4 000 8 000 63 125 250 500 1 000 2 000 4 000 8 000
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

Ceiling Concealed Duct(High Static) _ 31


9. Sound Levels
ARNU18GBHA2 ARNU24GBHA2
80 80

n High n High
▲ Mid ▲ Mid
70
l Low 70
l Low
Octave Band Sound Pressure Level (0 dB = 20 μPa)

Octave Band Sound Pressure Level (0 dB = 20 μPa)


NC-65 NC-65
60 60
NC-60 NC-60

NC-55 NC-55
50 50
NC-50 NC-50

NC-45 NC-45
40 40
NC-40 NC-40

NC-35 NC-35
30 30
NC-30 NC-30

NC-25 NC-25
20 20
Approximate Approximate
NC-20 NC-20
Hearing Hearing
Threshold Threshold
NC-15 NC-15
10 10
63 125 250 500 1 000 2 000 4 000 8 000 63 125 250 500 1 000 2 000 4 000 8 000
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)
Indoor Units

Sound Pressure Level (50Pa)


ARNU07GBHA2 ARNU09GBHA2 ARNU12GBHA2 ARNU15GBHA2
80 80 80

n High n High n High


▲ Mid ▲ Mid ▲ Mid
70 l Low 70 l Low 70 l Low
Octave Band Sound Pressure Level (0 dB = 20 μPa)

Octave Band Sound Pressure Level (0 dB = 20 μPa)

Octave Band Sound Pressure Level (0 dB = 20 μPa)


NC-65 NC-65 NC-65
60 60 60
NC-60 NC-60 NC-60

NC-55 NC-55 NC-55


50 50 50
NC-50 NC-50 NC-50

NC-45 NC-45 NC-45


40 40 40
NC-40 NC-40 NC-40

NC-35 NC-35 NC-35


30 30 30
NC-30 NC-30 NC-30

NC-25 NC-25 NC-25


20 20 20
Approximate Approximate Approximate
NC-20 NC-20 NC-20
Hearing Hearing Hearing
Threshold Threshold Threshold
NC-15 NC-15 NC-15
10 10 10
63 125 250 500 1 000 2 000 4 000 8 000 63 125 250 500 1 000 2 000 4 000 8 000 63 125 250 500 1 000 2 000 4 000 8 000
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

ARNU18GBHA2 ARNU24GBHA2
80 80

n High n High
▲ Mid ▲ Mid
70 l Low 70 l Low
Octave Band Sound Pressure Level (0 dB = 20 μPa)

Octave Band Sound Pressure Level (0 dB = 20 μPa)

NC-65 NC-65
60 60
NC-60 NC-60

NC-55 NC-55
50 50
NC-50 NC-50

NC-45 NC-45
40 40
NC-40 NC-40

NC-35 NC-35
30 30
NC-30 NC-30

NC-25 NC-25
20 20
Approximate Approximate
NC-20 NC-20
Hearing Hearing
Threshold Threshold
NC-15 NC-15
10 10
63 125 250 500 1 000 2 000 4 000 8 000 63 125 250 500 1 000 2 000 4 000 8 000
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

32 _ Ceiling Concealed Duct(High Static)


9. Sound Levels
Sound Pressure Level (70Pa)
ARNU07GBHA2 ARNU09GBHA2 ARNU12GBHA2 ARNU15GBHA2
80 80 80

n High n High n High


▲ Mid ▲ Mid ▲ Mid
70 l Low 70 l Low 70 l Low
Octave Band Sound Pressure Level (0 dB = 20 μPa)

Octave Band Sound Pressure Level (0 dB = 20 μPa)

Octave Band Sound Pressure Level (0 dB = 20 μPa)


NC-65 NC-65 NC-65
60 60 60
NC-60 NC-60 NC-60

NC-55 NC-55 NC-55


50 50 50
NC-50 NC-50 NC-50

NC-45 NC-45 NC-45


40 40 40
NC-40 NC-40 NC-40

NC-35 NC-35 NC-35


30 30 30
NC-30 NC-30 NC-30

NC-25 NC-25 NC-25


20 20 20
Approximate Approximate Approximate
NC-20 NC-20 NC-20
Hearing Hearing Hearing
Threshold Threshold Threshold
NC-15 NC-15 NC-15
10 10 10
63 125 250 500 1 000 2 000 4 000 8 000 63 125 250 500 1 000 2 000 4 000 8 000 63 125 250 500 1 000 2 000 4 000 8 000
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

Indoor Units
ARNU18GBHA2 ARNU24GBHA2
80 80

n High n High
▲ Mid ▲ Mid
70 l Low 70 l Low
Octave Band Sound Pressure Level (0 dB = 20 μPa)

Octave Band Sound Pressure Level (0 dB = 20 μPa)

NC-65 NC-65
60 60
NC-60 NC-60

NC-55 NC-55
50 50
NC-50 NC-50

NC-45 NC-45
40 40
NC-40 NC-40

NC-35 NC-35
30 30
NC-30 NC-30

NC-25 NC-25
20 20
Approximate Approximate
NC-20 NC-20
Hearing Hearing
Threshold Threshold
NC-15 NC-15
10 10
63 125 250 500 1 000 2 000 4 000 8 000 63 125 250 500 1 000 2 000 4 000 8 000
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

Sound Pressure Level (100Pa)


ARNU07GBHA2 ARNU09GBHA2 ARNU12GBHA2 ARNU15GBHA2
80 80 80

n High n High n High


▲ Mid ▲ Mid ▲ Mid
70 l Low 70 l Low 70 l Low
Octave Band Sound Pressure Level (0 dB = 20 μPa)

Octave Band Sound Pressure Level (0 dB = 20 μPa)

Octave Band Sound Pressure Level (0 dB = 20 μPa)

NC-65 NC-65 NC-65


60 60 60
NC-60 NC-60 NC-60

NC-55 NC-55 NC-55


50 50 50
NC-50 NC-50 NC-50

NC-45 NC-45 NC-45


40 40 40
NC-40 NC-40 NC-40

NC-35 NC-35 NC-35


30 30 30
NC-30 NC-30 NC-30

NC-25 NC-25 NC-25


20 20 20
Approximate Approximate Approximate
NC-20 NC-20 NC-20
Hearing Hearing Hearing
Threshold Threshold Threshold
NC-15 NC-15 NC-15
10 10 10
63 125 250 500 1 000 2 000 4 000 8 000 63 125 250 500 1 000 2 000 4 000 8 000 63 125 250 500 1 000 2 000 4 000 8 000
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

Ceiling Concealed Duct(High Static) _ 33


9. Sound Levels
ARNU18GBHA2 ARNU24GBHA2
80 80

n High n High
▲ Mid ▲ Mid
70 l Low 70 l Low
Octave Band Sound Pressure Level (0 dB = 20 μPa)

Octave Band Sound Pressure Level (0 dB = 20 μPa)


NC-65 NC-65
60 60
NC-60 NC-60

NC-55 NC-55
50 50
NC-50 NC-50

NC-45 NC-45
40 40
NC-40 NC-40

NC-35 NC-35
30 30
NC-30 NC-30

NC-25 NC-25
20 20
Approximate Approximate
NC-20 NC-20
Hearing Hearing
Threshold Threshold
NC-15 NC-15
10 10
63 125 250 500 1 000 2 000 4 000 8 000 63 125 250 500 1 000 2 000 4 000 8 000
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)
Indoor Units

Sound Pressure Level (120Pa)


ARNU07GBHA2 ARNU09GBHA2 ARNU12GBHA2 ARNU15GBHA2
80 80 80

n High n High n High


▲ Mid ▲ Mid ▲ Mid
70 l Low 70 l Low 70 l Low
Octave Band Sound Pressure Level (0 dB = 20 μPa)

Octave Band Sound Pressure Level (0 dB = 20 μPa)

Octave Band Sound Pressure Level (0 dB = 20 μPa)


NC-65 NC-65 NC-65
60 60 60
NC-60 NC-60 NC-60

NC-55 NC-55 NC-55


50 50 50
NC-50 NC-50 NC-50

NC-45 NC-45 NC-45


40 40 40
NC-40 NC-40 NC-40

NC-35 NC-35 NC-35


30 30 30
NC-30 NC-30 NC-30

NC-25 NC-25 NC-25


20 20 20
Approximate Approximate Approximate
NC-20 NC-20 NC-20
Hearing Hearing Hearing
Threshold Threshold Threshold
NC-15 NC-15 NC-15
10 10 10
63 125 250 500 1 000 2 000 4 000 8 000 63 125 250 500 1 000 2 000 4 000 8 000 63 125 250 500 1 000 2 000 4 000 8 000
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

ARNU18GBHA2 ARNU24GBHA2
80 80
n High n High
▲ Mid ▲ Mid
70 l Low 70 l Low
Octave Band Sound Pressure Level (0 dB = 20 μPa)

Octave Band Sound Pressure Level (0 dB = 20 μPa)

NC-65 NC-65
60 60
NC-60 NC-60

NC-55 NC-55
50 50
NC-50 NC-50

NC-45 NC-45
40 40
NC-40 NC-40

NC-35 NC-35
30 30
NC-30 NC-30

NC-25 NC-25
20 20
Approximate Approximate
NC-20 NC-20
Hearing Hearing
Threshold Threshold
NC-15 NC-15
10 10
63 125 250 500 1 000 2 000 4 000 8 000 63 125 250 500 1 000 2 000 4 000 8 000
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

34 _ Ceiling Concealed Duct(High Static)


9. Sound Levels
Sound Pressure Levels (dB(A),H-M-L)
Model External Static Pressure (Pa)
50 80 100 120 140 160
ARNU28GBGA2 29-25-23 33-29-26 34-33-30 35-34-31 36-35-32 37-36-33
ARNU36GBGA2 33-31-28 36-34-31 37-35-32 39-37-34 40-38-35 41-39-36
ARNU42GBGA2 36-33-30 39-36-33 40-38-35 42-39-36 43-40-37 44-41-38

Sound Pressure Level (50Pa)


ARNU28GBGA2 ARNU36GBGA2 ARNU42GBGA2
80 80 80

n High n High n High


▲ Mid ▲ Mid ▲ Mid
70 l Low 70 l Low 70 l Low
Octave Band Sound Pressure Level (0 dB = 20 μPa)

Octave Band Sound Pressure Level (0 dB = 20 μPa)

Octave Band Sound Pressure Level (0 dB = 20 μPa)


NC-65 NC-65 NC-65
60 60 60
NC-60 NC-60 NC-60

Indoor Units
NC-55 NC-55 NC-55
50 50 50
NC-50 NC-50 NC-50

NC-45 NC-45 NC-45


40 40 40
NC-40 NC-40 NC-40

NC-35 NC-35 NC-35


30 30 30
NC-30 NC-30 NC-30

NC-25 NC-25 NC-25


20 20 20
Approximate Approximate Approximate
NC-20 NC-20 NC-20
Hearing Hearing Hearing
Threshold Threshold Threshold
NC-15 NC-15 NC-15
10 10 10
63 125 250 500 1 000 2 000 4 000 8 000 63 125 250 500 1 000 2 000 4 000 8 000 63 125 250 500 1 000 2 000 4 000 8 000
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

Sound Pressure Level (80Pa)


ARNU28GBGA2 ARNU36GBGA2 ARNU42GBGA2
80 80 80

n High n High n High


▲ Mid ▲ Mid ▲ Mid
70 l Low 70 l Low 70 l Low
Octave Band Sound Pressure Level (0 dB = 20 μPa)
Octave Band Sound Pressure Level (0 dB = 20 μPa)

Octave Band Sound Pressure Level (0 dB = 20 μPa)

NC-65 NC-65 NC-65


60 60 60
NC-60 NC-60 NC-60

NC-55 NC-55 NC-55


50 50 50
NC-50 NC-50 NC-50

NC-45 NC-45 NC-45


40 40 40
NC-40 NC-40 NC-40

NC-35 NC-35 NC-35


30 30 30
NC-30 NC-30 NC-30

NC-25 NC-25 NC-25


20 20 20
Approximate Approximate Approximate
NC-20 NC-20 NC-20
Hearing Hearing Hearing
Threshold Threshold Threshold
NC-15 NC-15 NC-15
10 10 10
63 125 250 500 1 000 2 000 4 000 8 000 63 125 250 500 1 000 2 000 4 000 8 000 63 125 250 500 1 000 2 000 4 000 8 000
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

Ceiling Concealed Duct(High Static) _ 35


9. Sound Levels
Sound Pressure Level (100Pa)
ARNU28GBGA2 ARNU36GBGA2 ARNU42GBGA2
80 80 80
n High n High n High
▲ Mid ▲ Mid ▲ Mid
70 l Low 70 l Low 70 l Low

Octave Band Sound Pressure Level (0 dB = 20 μPa)


Octave Band Sound Pressure Level (0 dB = 20 μPa)

Octave Band Sound Pressure Level (0 dB = 20 μPa)


NC-65 NC-65 NC-65
60 60 60
NC-60 NC-60 NC-60

NC-55 NC-55 NC-55


50 50 50
NC-50 NC-50 NC-50

NC-45 NC-45 NC-45


40 40 40
NC-40 NC-40 NC-40

NC-35 NC-35 NC-35


30 30 30
NC-30 NC-30 NC-30

NC-25 NC-25 NC-25


20 20 20
Approximate Approximate Approximate
NC-20 NC-20 NC-20
Hearing Hearing Hearing
Threshold Threshold Threshold
NC-15 NC-15 NC-15
10 10 10
63 125 250 500 1 000 2 000 4 000 8 000 63 125 250 500 1 000 2 000 4 000 8 000 63 125 250 500 1 000 2 000 4 000 8 000
Indoor Units

Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

Sound Pressure Level (120Pa)


ARNU28GBGA2 ARNU36GBGA2 ARNU42GBGA2
80 80 80

n High n High n High


▲ Mid ▲ Mid ▲ Mid
70 l Low 70 l Low 70 l Low
Octave Band Sound Pressure Level (0 dB = 20 μPa)
Octave Band Sound Pressure Level (0 dB = 20 μPa)

Octave Band Sound Pressure Level (0 dB = 20 μPa)

NC-65 NC-65 NC-65


60 60 60
NC-60 NC-60 NC-60

NC-55 NC-55 NC-55


50 50 50
NC-50 NC-50 NC-50

NC-45 NC-45 NC-45


40 40 40
NC-40 NC-40 NC-40

NC-35 NC-35 NC-35


30 30 30
NC-30 NC-30 NC-30

NC-25 NC-25 NC-25


20 20 20
Approximate Approximate Approximate
NC-20 NC-20 NC-20
Hearing Hearing Hearing
Threshold Threshold Threshold
NC-15 NC-15 NC-15
10 10 10
63 125 250 500 1 000 2 000 4 000 8 000 63 125 250 500 1 000 2 000 4 000 8 000 63 125 250 500 1 000 2 000 4 000 8 000
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

36 _ Ceiling Concealed Duct(High Static)


9. Sound Levels
Sound Pressure Level (140Pa)
ARNU28GBGA2 ARNU36GBGA2 ARNU42GBGA2
80 80 80

n High n High n High


▲ Mid ▲ Mid ▲ Mid
70 l Low 70 l Low 70 l Low

Octave Band Sound Pressure Level (0 dB = 20 μPa)


Octave Band Sound Pressure Level (0 dB = 20 μPa)

Octave Band Sound Pressure Level (0 dB = 20 μPa)


NC-65 NC-65 NC-65
60 60 60
NC-60 NC-60 NC-60

NC-55 NC-55 NC-55


50 50 50
NC-50 NC-50 NC-50

NC-45 NC-45 NC-45


40 40 40
NC-40 NC-40 NC-40

NC-35 NC-35 NC-35


30 30 30
NC-30 NC-30 NC-30

NC-25 NC-25 NC-25


20 20 20
Approximate Approximate Approximate
NC-20 NC-20 NC-20
Hearing Hearing Hearing
Threshold Threshold Threshold
NC-15 NC-15 NC-15
10 10 10

Indoor Units
63 125 250 500 1 000 2 000 4 000 8 000 63 125 250 500 1 000 2 000 4 000 8 000 63 125 250 500 1 000 2 000 4 000 8 000
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

Sound Pressure Level (160Pa)


ARNU28GBGA2 ARNU36GBGA2 ARNU42GBGA2
80 80 80

n High n High n High


▲ Mid ▲ Mid ▲ Mid
70 l Low 70 l Low 70 l Low
Octave Band Sound Pressure Level (0 dB = 20 μPa)
Octave Band Sound Pressure Level (0 dB = 20 μPa)

Octave Band Sound Pressure Level (0 dB = 20 μPa)

NC-65 NC-65 NC-65


60 60 60
NC-60 NC-60 NC-60

NC-55 NC-55 NC-55


50 50 50
NC-50 NC-50 NC-50

NC-45 NC-45 NC-45


40 40 40
NC-40 NC-40 NC-40

NC-35 NC-35 NC-35


30 30 30
NC-30 NC-30 NC-30

NC-25 NC-25 NC-25


20 20 20
Approximate Approximate Approximate
NC-20 NC-20 NC-20
Hearing Hearing Hearing
Threshold Threshold Threshold
NC-15 NC-15 NC-15
10 10 10
63 125 250 500 1 000 2 000 4 000 8 000 63 125 250 500 1 000 2 000 4 000 8 000 63 125 250 500 1 000 2 000 4 000 8 000
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

Ceiling Concealed Duct(High Static) _ 37


9. Sound Levels
Sound Pressure Levels (dB(A),H-M-L)
Model External Static Pressure (Pa)
50 70 100 140 170
ARNU48GBRA2 38-36-34 39-37-35 40-39-37 41-40-38 42-41-39
ARNU54GBRA2 39-37-35 40-38-36 41-39-38 - -

Sound Pressure Level (50Pa)


ARNU48GBRA2 ARNU54GBRA2
80 80

n High n High
▲ Mid ▲ Mid
70 l Low 70 l Low
Octave Band Sound Pressure Level (0 dB = 20 μPa)

Octave Band Sound Pressure Level (0 dB = 20 μPa)

NC-65 NC-65
60 60
NC-60 NC-60

NC-55 NC-55
50 50
NC-50 NC-50
Indoor Units

NC-45 NC-45
40 40
NC-40 NC-40

NC-35 NC-35
30 30
NC-30 NC-30

NC-25 NC-25
20 20
Approximate Approximate
NC-20 NC-20
Hearing Hearing
Threshold Threshold
NC-15 NC-15
10 10
63 125 250 500 1 000 2 000 4 000 8 000 63 125 250 500 1 000 2 000 4 000 8 000
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

Sound Pressure Level (70Pa)


ARNU48GBRA2 ARNU54GBRA2
80 80
n High n High
▲ Mid ▲ Mid
70 l Low 70 l Low
Octave Band Sound Pressure Level (0 dB = 20 μPa)

Octave Band Sound Pressure Level (0 dB = 20 μPa)

NC-65 NC-65
60 60
NC-60 NC-60

NC-55 NC-55
50 50
NC-50 NC-50

NC-45 NC-45
40 40
NC-40 NC-40

NC-35 NC-35
30 30
NC-30 NC-30

NC-25 NC-25
20 20
Approximate Approximate
NC-20 NC-20
Hearing Hearing
Threshold Threshold
NC-15 NC-15
10 10
63 125 250 500 1 000 2 000 4 000 8 000 63 125 250 500 1 000 2 000 4 000 8 000
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

38 _ Ceiling Concealed Duct(High Static)


9. Sound Levels
Sound Pressure Level (100Pa)
ARNU48GBRA2 ARNU54GBRA2
80 80

n High n High
▲ Mid ▲ Mid
70 l Low 70 l Low
Octave Band Sound Pressure Level (0 dB = 20 μPa)

Octave Band Sound Pressure Level (0 dB = 20 μPa)


NC-65 NC-65
60 60
NC-60 NC-60

NC-55 NC-55
50 50
NC-50 NC-50

NC-45 NC-45
40 40
NC-40 NC-40

NC-35 NC-35
30 30
NC-30 NC-30

NC-25 NC-25
20 20
Approximate Approximate
NC-20 NC-20
Hearing Hearing
Threshold Threshold
NC-15 NC-15
10 10
63 125 250 500 1 000 2 000 4 000 8 000 63 125 250 500 1 000 2 000 4 000 8 000

Indoor Units
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

Sound Pressure Level (140Pa) Sound Pressure Level (170Pa)


ARNU48GBRA2 ARNU48GBRA2
80 80

n High n High
▲ Mid ▲ Mid
l Low 70 l Low
Octave Band Sound Pressure Level (0 dB = 20 μPa)

70
Octave Band Sound Pressure Level (0 dB = 20 μPa)

NC-65 NC-65
60 60

NC-60 NC-60

NC-55 NC-55
50 50

NC-50 NC-50

NC-45 NC-45
40 40

NC-40 NC-40

NC-35 NC-35
30 30

NC-30 NC-30

NC-25 NC-25
20 20
Approximate Approximate
NC-20 NC-20
Hearing Hearing
Threshold Threshold
NC-15 NC-15
10 10
63 125 250 500 1 000 2 000 4 000 8 000 63 125 250 500 1 000 2 000 4 000 8 000
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

Ceiling Concealed Duct(High Static) _ 39


9. Sound Levels
Sound Pressure Levels (dB(A),H-M-L)
Model External Static Pressure (Pa)
120 150 220
ARNU76GB8A2 41-40-40 42-41-41 45-43-43
ARNU96GB8A2 43-41-41 44-42-42 47-45-45

Sound Pressure Level (120Pa)


ARNU76GB8A2 ARNU96GB8A2
80 80

n High n High
▲ Mid ▲ Mid
70 l Low 70 l Low
Octave Band Sound Pressure Level (0 dB = 20 μPa)

Octave Band Sound Pressure Level (0 dB = 20 μPa)

NC-65 NC-65
60 60
NC-60 NC-60

NC-55 NC-55
50 50
Indoor Units

NC-50 NC-50

NC-45 NC-45
40 40
NC-40 NC-40

NC-35 NC-35
30 30
NC-30 NC-30

NC-25 NC-25
20 20
Approximate Approximate
NC-20 NC-20
Hearing Hearing
Threshold Threshold
NC-15 NC-15
10 10
63 125 250 500 1 000 2 000 4 000 8 000 63 125 250 500 1 000 2 000 4 000 8 000
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

Sound Pressure Level (150Pa)


ARNU76GB8A2 ARNU96GB8A2
80 80

n High n High
▲ Mid ▲ Mid
70
l Low 70
l Low
Octave Band Sound Pressure Level (0 dB = 20 μPa)

Octave Band Sound Pressure Level (0 dB = 20 μPa)

NC-65 NC-65
60 60
NC-60 NC-60

NC-55 NC-55
50 50
NC-50 NC-50

NC-45 NC-45
40 40
NC-40 NC-40

NC-35 NC-35
30 30
NC-30 NC-30

NC-25 NC-25
20 20
Approximate Approximate
NC-20 NC-20
Hearing Hearing
Threshold Threshold
NC-15 NC-15
10 10
63 125 250 500 1 000 2 000 4 000 8 000 63 125 250 500 1 000 2 000 4 000 8 000
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

40 _ Ceiling Concealed Duct(High Static)


9. Sound Levels
Sound Pressure Level (220Pa)
ARNU76GB8A2 ARNU96GB8A2
80 80

n High n High
▲ Mid ▲ Mid
70 l Low 70 l Low
Octave Band Sound Pressure Level (0 dB = 20 μPa)

Octave Band Sound Pressure Level (0 dB = 20 μPa)


NC-65 NC-65
60 60
NC-60 NC-60

NC-55 NC-55
50 50
NC-50 NC-50

NC-45 NC-45
40 40
NC-40 NC-40

NC-35 NC-35
30 30
NC-30 NC-30

NC-25 NC-25
20 20
Approximate Approximate
NC-20 NC-20
Hearing Hearing
Threshold Threshold
NC-15 NC-15
10 10
63 125 250 500 1 000 2 000 4 000 8 000 63 125 250 500 1 000 2 000 4 000 8 000

Indoor Units
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

Ceiling Concealed Duct(High Static) _ 41


10. Installation
• Please read this instruction sheet completely before installing the product.
• When the power cord is damaged, replacement work shall be performed by authorized personnel only.
• Installation work must be performed in accordance with the national wiring standards by authorized personnel only.

Air outlet vents Air filters

Air intake vents


TEMP

Wired LCD Remote Control


Remote Controller

Required Parts Required Tools


Indoor Units

• Connecting cable • Level


• Pipes: Gas side • Screw driver
Liquid side • Electric drill
• Hanging Bolt • Hole core drill
(W 3/8 or M10 length 650mm)
• Flaring Tool set
• Insulated drain hose
• Torque Wrenches
• Additional Drain hose
• Hexagonal Wrench
• Gas-leak detector
• Thermometer

10.1 Selection of the best location


Install the air conditioner in the location that satisfies the
[600(23-5/8) x 600(23-5/8)]
following conditions.
• The place shall easily bear a load exceeding four times
the indoor unitʼs weight.
• The place shall be able to inspect the unit as the figure.
• The place where the unit shall be leveled.
• The place shall allow easy water drainage.
(Suitable dimension “H” is necessary to get a slope to
(39-3/8)
1000

drain as figure.) 600 600


[Unit: mm(inch)] (23-5/8) (23-5/8)
• The place shall easily connect with the outdoor unit.
• The place where the unit is not affected by an electrical
noise.
• The place where air circulation in the room will be good .
• There should not be any heat source or steam near the
unit.
• The servicing inspection hole in the ceiling should be as
large as the product H = 20(25/32) or more
• The selection of the servicing hole should be approved [Unit: mm(inch)]
by the customer

42 _ Ceiling Concealed Duct(High Static)


10. Installation
10.2 Ceiling dimension and hanging BH/BG/BR Chassis
A
bolt location B
n Installation of Unit
Install the unit above the ceiling correctly.

C
CASE 1

E
POSITION OF SUSPENSION BOLT

D
• Apply a joint-canvas between the unit and duct to absorb (G)

F
unnecessary vibration.
• Apply a filter Accessory at air return hole.
• Refer to the Dimensions.
(Unit:mm)

I
Dimension
A B C D E F (G) H I H
Chassis
Drainage hole

Indoor Units
BH 932 882 355 47 450 30 87 750 158
BG 1232 1182 355 47 450 30 87 830 186
BR 1282 1230 477 56 590 30 120 1006 294 B8 Chassis
A
(Unit:mm) K L
B
Dimension F J
A B C D E F G H I J K L
Chassis
B8 1622 1565 580 292 695 1400 460 1122 1680 390 445 15
EC
• Install the unit leaning to a drainage hole side as a figure
for easy water drainage.

GD

H
I
CASE 2

POSITION OF CONSOLE BOLT M10 Nut X4


• A place where the unit will be leveled and that can sup-
port the weight of the unit. M10 washer X4
• A place where the unit can withstand its vibration.
• A place where service can be easily performed.

M10 washer X4
M10 Nut X8

Ceiling Concealed Duct(High Static) _ 43


10. Installation
NOTE:• Throughly study the following installation locations:
1. In such places as restaurants and kitchens, considerable amount of oil steam and flour adhere to the fan, the fin of the heat
exchanger, resulting in heat exchange reduction, spraying, dispersing of water drops, etc.
In these cases, take the following actions:
• Make sure that the ventilation fan for smoke-collecting hood on a cooking table has sufficient capacity so that it draws oily
steam which should not flow into the suction of the air conditioner.
• Make enough distance from a cooking room to install the air conditioner in such a place where it may not suck in oil steam.
2. Avoid installing air conditioner in such circumstances where cutting oil mist or iron powder is in suspension in factories, etc.
3. Avoid places where inflammable gas is generated, flows in, is stored or vented.
4. Avoid places where sulfurous acid gas or corrosive gas is generated.
5. Avoid places near high frequency generators.
• Select and mark the position for fixing bolts. • Insert the set anchor and washer onto the suspension
• Drill the hole for set anchor on the face of ceiling. bolts for locking the suspension bolts on the ceiling.
• Mount the suspension bolts to the set anchor firmly.
• Secure the installation plates onto the suspension bolts (adjust
level roughly) using nuts, washers and spring washers.
Old building New building
Indoor Units

1 Set anchor
2 Plate washer
3 Spring washer
4 Nut
CAUTION 5 Suspension
Tighten the nut and bolt to prevent unit falling. bolts

10.3 Connecting Cables between Indoor Unit and Outdoor Unit


Connect the wires to the terminals on the control board individually according to the outdoor unit connection.
• Ensure that the color of the wires of outdoor unit and the terminal No. are the same as those of indoor unit respectively
[Indoor Unit side] [Outdoor Unit side]
[Type 1]

Terminal Block Indoor Terminal Block Indoor SODU B SODU A IDU B IDU A INT B INT A
1(L1) N(L2) 3 4

INDOOR POWER INPUT

[Type 2]
Terminal Block Indoor Terminal Block Indoor SODU IDU INTERNET DRY1 DRY2 GND 12V
1(L1) N(L2) 3 4 B A - - B A - - - -

INDOOR POWER INPUT


[Type 3]
Terminal block of outdoor unit
Terminal Block Indoor Terminal Block Indoor Central controller Indoor unit Outdoor unit
1(L1) N(L2) 3 4 12V GND DRY2 DRY1 CEN CEN IDU IDU SODU SODU

INDOOR POWER INPUT

WARNING
Make sure that the screws of the terminal are not loose.

Clamping of cables
1) Arrange 2 power cables on the control panel.
2) First, fasten the steel clamp with a screw to the inner boss of control panel.
3) For the cooling model, fix the other side of the clamp with a screw strongly. For the heat pump model, put the
0.75mm2 cable(thinner cable) on the clamp and tighten it with a plastic clamp to the other boss of the control panel.

44 _ Ceiling Concealed Duct(High Static)


10. Installation
THERMAL INSULATION All thermal insulation must comply with local requirement.

INDOOR UNIT
BH/BG/BR Chassis

Union for liquid pipe Thermal insulator for refrigerant pipe


(Local supply) Thermal insulator for
Refrigerant pipe and thermal
piping(Local supply)
insulator(Local supply)

Hose clamp for thermal insulator


(Local supply)
Overlap with thermal
Thermal insulator for refrigerant pipe insulator for piping.
B8 (Local supply) Hose clamp for thermal insulator(Local supply)
Union for gas pipe
Make sure that there is no clearance here.
Union for gas pipe

Indoor Units
Thermal insulator for refrigerant pipe
(Local supply)
Hose crip for thermal insulator
(Local supply)
Refrigerant pipe and therma
insulator(Local supply)

Union for liquid pipe

10.4 Checking the Drainage


BH/BG/BR Chassis
1) Checking the Drainage

1. Remove the Air Filter.

B8

2. Check the drainage.


• Spray one or two glasses of water on the evapo-
rator.
• Ensure that water flows through drain hose of
indoor unit without any leakage.

Ceiling Concealed Duct(High Static) _ 45


10. Installation
10.5 Indoor Unit Drain Piping Pipe clamp
Upward
routing
• Drain piping must have down-slope (1/50 to 1/100): be sure not to pro- not allowed
vide up-and-down slope to prevent reversal flow. Indoor unit
• During drain piping connection, be careful not to exert extra force on the
drain port on the indoor unit.
• The outside diameter of the drain connection on the indoor unit is 32mm. Maintenance
drain port
Piping material: Polyvinyl chloride pipe inner
diometes Ø 25mm and pipe fittings
• Be sure to install heat insulation on the drain piping. 1/50~1/100

Heat insulation material: Polyethylene foam with MAX 700mm

thickness more than 8 mm.

Drain test
Indoor Units

The air conditioner uses a drain pump to drain water.


Use the following procedure to test the drain pump operation:

Feed water Flexible drain hose


(accessory) • Connect the main drain pipe to the exterior and leave it pro-
Main visionally until the test comes to an end.
drain pipe • Feed water to the flexible drain hose and check the piping
for leakage.
Drain
Drain Pump port Glue the joint • Be sure to check the drain pump for normal operation and
noise when electrical wiring is complete.
Drain hose connection
Use the clip (accessory) • When the test is complete, connect the flexible drain hose to
the drain port on the indoor unit.

Drain pan

Hanger
Max 300mm distance Hanger Bracket
CAUTION 1~15m 1/50~1/100 slope
Metal Max 700mm
The supplied flexible drain hose should not be strained. clamp
A strained hose may cause leakage of water.
Flexible drain hose
Insulation

Flexible drain hose


Flexible drain hose
Flexible drain hose

46 _ Ceiling Concealed Duct(High Static)


10. Installation
10.6 Ground drain piping
a) It is standard work practice to make connections to the main pipe from above. The pipe down from the
combination should be as large as possible.

Face the vent pipe opening facing downward to


keep foreign matter from penetrating the system

Face piping
downward

Indoor Units
Vent pipe

b) The pipe work should be kept as short as possible and the number of indoor units per group kept to a
minimum.

10.7 Use of an auxiliary drain hose(flexible)


a) To connect drain pipe to the drain socket on the indoor unit, an auxiliary flexible drain hose should be
used. auxiliary flexible drain hose allows that the drain pipe can be connected to the socket without break-
ing by excessive strain.

Auxiliary drain hose


Thermal insulation (drain pipe area)

Metal clamp

Metal clamp
Thermal insulation(bend area)

Drain pan

h Important points
- The drain pipe should be at least equal in size to that of the indoor unit.
- The drain pipe is thermally insulated to prevent the formation of condensation inside the pipe.
- The drain up mechanism should be fitted before the indoor unit is installed and when the electricity has
been connected some water should be added to the drain pan and the drain pump to check and see if it is
functioning correctly.
- All connections should be secure. (Special care is needed with PVC pipe)
- Insulate auxiliary drain hose with thermal insulation band.

Ceiling Concealed Duct(High Static) _ 47


10. Installation
WIRED REMOTE CONTROLLER INSTALLATION
• Since the room temperature sensor is in the remote controller, the remote controller box should be installed in a place
away from direct sunlight, high humidity and direct supply of cold air to maintain proper space temperature.
Install the remote controller about 5ft(1.5m) above the floor in an area with good air circulation at an average tempera-
ture.
Do not install the remote controller where it can be affected by:
- Drafts, or dead spots behind doors and in corners.
- Hot or cold air from ducts.
- Radiant heat from sun or appliances.
- Concealed pipes and chimneys.
- Uncontrolled areas such as an outside wall behind the remote controller.
- This remote controller is equipped with a seven segment LED. display. For proper display of the remote controller
LED's, the remote controller should be installed properly as shown in Fig.1.
(The standard height is 1.2~1.5 m from floor level.)
Indoor Units

Remote Controller
TEMP
yes

no
TEMP

Remote Controller

no
TEMP
5feet
Remote
Controller

(1.5meters)

no

Fig.1 Typical locations for remote controller

48 _ Ceiling Concealed Duct(High Static)


11. Accessories
Standard Accessories
Washer for Clamp Insulation for
Name Drain hose Clamp metal (Other)
hanging backet (Tie Wrap) fitting

Quantity 1 EA 1 EA 8 EA 4 EA 1 SET

• Owner's manual
• Installation manual

Shape for gas pipe

for liquid pipe

Indoor Units
CAUTION
• Use only those accessories (Standard or optional) which have designated specifications.

Ceiling Concealed Duct(High Static) _ 49


Indoor unit

Ceiling Concealed Duct(High Static)(2)


1. List of functions

2. Specifications

3. Dimensions & Gravity point

4. Piping Diagrams

5. Wiring Diagrams

6. Capacity Tables

7. External Static Pressure(E.S.P) & Air Flow

8. Electric Characteristics

9. Sound Levels

10. Installation

11. Accessories
1. List of functions
ARNU12GBGA2, ARNU15GBGA2, ARNU18GBGA2, ARNU24GBGA2,
Category Function
ARNU28GBRA2, ARNU36GBRA2 ARNU42GBRA2

Air supply outlet 1


Airflow direction control(left & right) -
Airflow direction control(up & down) -
Auto swing(left & right) -
Auto swing(up & down) -
Air flow
Airflow steps(fan/cool/heat) 3/3/3
Chaos swing -
Chaos wind(auto wind) -
Jet cool(Power wind) -
Swirl wind -
Deodorizing filter X
Air purifying Plasma air purifier X
Prefilter(washable / anti-fungus) O
Drain pump O
E.S.P. control O
Installation

Indoor Units
Electric heater(operation) X
High ceiling operation -
Hot start O
Reliability Self diagnosis O
Soft dry operation O
Auto changeover O(Heat recovery)
Auto cleaning X
Auto operation(artificial intelligence) O(Heat pump or Cooling only)
Auto restart operation O
Child lock O
Convenience Forced operation -
Group control O
Sleep mode O
Timer(on/off) O
Timer(weekly) O
Two thermistor control O
Wide wired remote controller PQRCVSL0/PQRCVSL0QW
Deluxe wired remote controller PQRCUDS0(B/S)
Individual Simple wired remote controller PQRCVCL0Q(W)
control Wired remote controller(for hotel use) PQRCHCA0Q(W)
Wireless LCD remote control PQWRH(C)Q0FDB
Zone control X
CTIE -
Special Electro thermostat -
function kit Remote temperature sensor PQRSTA0
Group control wire PZCWRCG3
Dry contact PQDSA(1)/PQDSB(1)/PQDSBC/PQDSBNGCM1/PQDSBCGCD0

O : Applied X : Not applied – : No relation


Option : Model name & price are different according to options, and assembled in factory with main unit.
Accessory : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate
package.

Ceiling Concealed Duct(High Static)(2) _ 1


2. Specifications
Type Ceiling Concealed Duct (High Static)(2)
Model Unit ARNU12GBGA2 ARNU15GBGA2 ARNU18GBGA2
kW 3.6 4.5 5.6
Cooling Capacity kcal/h 3,100 3,900 4,800
Btu/h 12,300 15,400 19,100
kW 4.0 5.0 6.3
Heating Capacity kcal/h 3,400 4,300 5,400
Btu/h 13,600 17,100 21,500
Casing Galvanized Steel Plate Galvanized Steel Plate Galvanized Steel Plate
Dimensions mm 1,182 x 298 x 450 1,182 x 298 x 450 1,182 x 298 x 450
Body
(W x H x D) inch 46-17/32 x 11-23/32 x 17-23/32 46-17/32 x 11-23/32 x 17-23/32 46-17/32 x 11-23/32 x 17-23/32
Rows x Columns x FPI 3 x 12 x 21 3 x 12 x 21 3 x 12 x 21
Coil
Face Area m2 0.26 0.26 0.26
Type Sirocco Fan Sirocco Fan Sirocco Fan
Motor Output x Number W 350 350 350
Running Current A 2.3 2.3 2.3
Air Flow Rate(H/M/L) CMM 13.5/12.1/9.4 13.8/11.8/9.5 15.2/13.8/11.8
Indoor Units

(High Mode-factory set) cfm 477/427/332 487/417/336 537/487/417


Fan External Static Pressure mmAq(Pa) 6(60) 8(80) 8(80)
Air Flow Rate(H/M/L) CMM 16.6/15.1/13.7 13.5/12.1/9.0 15.5/13.3/12.1
(Standard Mode) cfm 586/533/483 477/427/318 547/470/427
External Static Pressure mmAq(Pa) 4(40) 6(60) 6(60)
Drive Direct Direct Direct
Motor type BLDC BLDC BLDC
Temperature Control Microprocessor, Thermostat for cooling and heating
Sound Absorbing Material Control Foamed polystrene Foamed polystrene Foamed polystrene
Air Filter - - -
Safety Device Fuse Fuse Fuse
Liquid Side mm(inch) Ø9.52(3/8) Ø9.52(3/8) Ø9.52(3/8)
Pipe
Gas Side mm(inch) Ø15.88(5/8) Ø15.88(5/8) Ø15.88(5/8)
Connections
Drain Pipe(Internal Dia.) mm(inch) 25(1) 25(1) 25(1)
Net Weight kg(lbs) 38(83.8) 38(83.8) 38(83.8)
Noise Level(SoundPress, 1.5m, H/M/L) dB(A) 32/31/30 33/32/31 33/32/31
1, 220-240, 50 1, 220-240, 50 1, 220-240, 50
Power Supply Ø, V, Hz
1, 220, 60 1, 220, 60 1, 220, 60
Refrigerant Control EEV EEV EEV
Power cable mm2 CV1.5 x 3C CV1.5 x 3C CV1.5 x 3C
Transmission Cable mm2 CVV-SB 1.0~1.5 x 2C CVV-SB 1.0~1.5 x 2C CVV-SB 1.0~1.5 x 2C
Notes:
Conversion Formula
1. Capacities are based on the following conditions:
Cooling • Indoor temp. 27°C[80.6°F]DB/ 19°C[66.2°F]WB kcal/h= kW x 860
• Outdoor temp. 35°C[95°F]DB/ 24°C[75.2°F]WB Btu/h = kW x 3412
• Interconnecting Piping Length 7.5m cfm = m3/min x 35.3
• Level Difference of Zero l/s = CMM x 1000/60
Heating • Indoor temp. 20°C[68°F]DB/ 15°C[59°F]WB
• Outdoor temp. 7°C[44.6°F]DB/ 6°C[42.8°F]WB
• Interconnecting Piping Length 7.5m
• Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve
6. Noise Level is High Mode
7. Anechoic chamber conversion value is measured at 1.5 m downward from unit centre at standard mode.
The values depends on the ambient conditions and values are normally higher in actual operation.

2 _ Ceiling Concealed Duct(High Static)(2)


2. Specifications
Type Ceiling Concealed Duct (High Static)(2)
Model Unit ARNU24GBGA2 ARNU28GBRA2
kW 7.1 8.2
Cooling Capacity kcal/h 6,100 7,100
Btu/h 24,200 28,000
kW 8.0 9.2
Heating Capacity kcal/h 6,900 8,000
Btu/h 27,300 31,500
Casing Galvanized Steel Plate Galvanized Steel Plate
Dimensions mm 1,182 x 298 x 450 1,230 x 380 x 590
Body
(W x H x D) inch 46-17/32 x 11-23/32 x 17-23/32 48-7/16 x 14-31/32 x 23-7/32
Rows x Columns x FPI 3 x 12 x 21 3 x 13 x 19
Coil
Face Area m2 0.26 0.38
Type Sirocco Fan Sirocco Fan
Motor Output x Number W 350 185 x 2
Running Current A 2.3 2.4
Air Flow Rate(H/M/L) CMM 19.0/15.2/13.8 36.2/32.1/28.5

Indoor Units
(High Mode-factory set) cfm 671/537/487 1,278/1,134/1,007
Fan External Static Pressure mmAq(Pa) 8(80) 14(140)
Air Flow Rate(H/M/L) CMM 19.0/16.3/15.5 32.6/31.3/30.4
(Standard Mode) cfm 671/576/547 1,151/1,105/1,074
External Static Pressure mmAq(Pa) 6(60) 10(100)
Drive Direct Direct
Motor type BLDC BLDC
Temperature Control Microprocessor, Thermostat for cooling and heating
Sound Absorbing Material Control Foamed polystrene Foamed polystrene
Air Filter - -
Safety Device Fuse Fuse
Liquid Side mm(inch) Ø9.52(3/8) Ø9.52(3/8)
Pipe
Gas Side mm(inch) Ø15.88(5/8) Ø15.88(5/8)
Connections
Drain Pipe(Internal Dia.) mm(inch) 25(1) 25(1)
Net Weight kg(lbs) 38(83.8) 53(116.8)
Noise Level(SoundPress, 1.5m, H/M/L) dB(A) 36/35/33 41/40/39
1, 220-240, 50 1, 220-240, 50
Power Supply Ø, V, Hz
1, 220, 60 1, 220, 60
Refrigerant Control EEV EEV
Power cable mm2 CV1.5 x 3C CV1.5 x 3C
Transmission Cable mm2 CVV-SB 1.0~1.5 x 2C CVV-SB 1.0-1.5 x 2C
Notes:
Conversion Formula
1. Capacities are based on the following conditions:
Cooling • Indoor temp. 27°C[80.6°F]DB/ 19°C[66.2°F]WB kcal/h= kW x 860
• Outdoor temp. 35°C[95°F]DB/ 24°C[75.2°F]WB Btu/h = kW x 3412
• Interconnecting Piping Length 7.5m cfm = m3/min x 35.3
• Level Difference of Zero l/s = CMM x 1000/60
Heating • Indoor temp. 20°C[68°F]DB/ 15°C[59°F]WB
• Outdoor temp. 7°C[44.6°F]DB/ 6°C[42.8°F]WB
• Interconnecting Piping Length 7.5m
• Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve
6. Noise Level is High Mode
7. Anechoic chamber conversion value is measured at 1.5 m downward from unit centre at standard mode.
The values depends on the ambient conditions and values are normally higher in actual operation.

Ceiling Concealed Duct(High Static)(2) _ 3


2. Specifications
Type Ceiling Concealed Duct (High Static)(2)
Model Unit ARNU36GBRA2 ARNU42GBRA2
kW 10.6 12.3
Cooling Capacity kcal/h 9,100 10,600
Btu/h 36,200 42,000
kW 11.9 13.8
Heating Capacity kcal/h 10,200 11,000
Btu/h 40,600 43,800
Casing Galvanized Steel Plate Galvanized Steel Plate
Dimensions mm 1,230 x 380 x 590 1,230 x 380 x 590
Body
(W x H x D) inch 48-7/16 x 14-31/32 x 23-7/32 48-7/16 x 14-31/32 x 23-7/32
Rows x Columns x FPI 3 x 13 x 19 3 x 13 x 19
Coil
Face Area m2 0.38 0.38
Type Sirocco Fan Sirocco Fan
Motor Output x Number W 185 x 2 185 x 2
Running Current A 2.4 2.4
Air Flow Rate(H/M/L) CMM 39.1/33.3/29.7 42.2/39.1/33.3
Indoor Units

(High Mode-factory set) cfm 1,381/1,176/1,049 1,490/1,381/1,176


Fan External Static Pressure mmAq(Pa) 14(140) 14(140)
Air Flow Rate(H/M/L) CMM 40.5/32.6/31.3 42.4/40.5/32.6
(Standard Mode) cfm 1,430/1,151/1,105 1,497/1,430/1,151
External Static Pressure mmAq(Pa) 10(100) 10(100)
Drive Direct Direct
Motor type BLDC BLDC
Temperature Control Microprocessor, Thermostat for cooling and heating
Sound Absorbing Material Control Foamed polystrene Foamed polystrene
Air Filter - -
Safety Device Fuse Fuse
Liquid Side mm(inch) Ø9.52(3/8) Ø9.52(3/8)
Pipe
Gas Side mm(inch) Ø15.88(5/8) Ø15.88(5/8)
Connections
Drain Pipe(Internal Dia.) mm(inch) 25(1) 25(1)
Net Weight kg(lbs) 53(116.8) 53(116.8)
Noise Level(SoundPress, 1.5m, H/M/L) dB(A) 42/41/40 43/42/41
1, 220-240, 50 1, 220-240, 50
Power Supply Ø, V, Hz
1, 220, 60 1, 220, 60
Refrigerant Control EEV EEV
Power cable mm2 CV1.5 x 3C CV1.5 x 3C
Transmission Cable mm2 CVV-SB 1.0-1.5 x 2C CVV-SB 1.0-1.5 x 2C
Notes:
Conversion Formula
1. Capacities are based on the following conditions:
Cooling • Indoor temp. 27°C[80.6°F]DB/ 19°C[66.2°F]WB kcal/h= kW x 860
• Outdoor temp. 35°C[95°F]DB/ 24°C[75.2°F]WB Btu/h = kW x 3412
• Interconnecting Piping Length 7.5m cfm = m3/min x 35.3
• Level Difference of Zero l/s = CMM x 1000/60
Heating • Indoor temp. 20°C[68°F]DB/ 15°C[59°F]WB
• Outdoor temp. 7°C[44.6°F]DB/ 6°C[42.8°F]WB
• Interconnecting Piping Length 7.5m
• Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve
6. Noise Level is High Mode
7. Anechoic chamber conversion value is measured at 1.5 m downward from unit centre at standard mode.
The values depends on the ambient conditions and values are normally higher in actual operation.

4 _ Ceiling Concealed Duct(High Static)(2)


4 Ceiling Concealed Duct (High Static)(2)
1,043 115
ARNU12GBGA2

20
ARNU15GBGA2
ARNU18GBGA2

220
ARNU24GBGA2

(unit : mm)
6
1,232 Number Name Descripition
102
51 32 1 Liquid pipe connection Unit size(12k,15k,18k,24k):Ø9.52
23

47 2 Gas pipe connection Unit size(12k,15k,18k,24k):Ø15.88


50
152 53 165
ø1

224
00 3 Drain pipe connection
100

450
60

355
4 Power supply connection
122 140 5 Air discharge

219
87 1
6 Air suction
2
49
565 3
30 77 261
87
830
5
3. Dimensions & Gravity point

1,182 108

Note

158

186
1. Unit should be installed in compliance with the installation manual

298
in the product box.

113
136
2. Unit shall be grounded in accordance with the local regulations or
232 243 232 243 232 applicable national codes.

Gravity point

450
1,182

76, Seongsan-dong, Changwon City, Gyeongnam,


641-713, Korea CHASSIS CODE: BG

Ceiling Concealed Duct(High Static)(2) _ 5


Indoor Units
Indoor Units

Ceiling Concealed Duct (High Static)(2)


1,092 120 4

25
ARNU28GBRA2
ARNU36GBRA2

303
ARNU42GBRA2

(unit : mm)
6 101
1,282 Number Name Descripition
83
1,230 115 26 1 Liquid pipe connection Unit size(28k,32k,36k,42k):Ø9.52

72
2 Gas pipe connection Unit size(28k,32k,36k,42k):Ø15.88

123
221
198
3 Drain pipe connection

312
R6
0

90
60 4 Power supply connection

477
590
5 Air discharge

122
144
1

302
2 6 Air suction

56
50 3
114

32
621 135
118 190

6 _ Ceiling Concealed Duct(High Static)(2)


1,006 260
5
Note
3. Dimensions & Gravity point

1. Unit should be installed in compliance with the installation manual


in the product box.

178

140
2. Unit shall be grounded in accordance with the local regulations or

294

380
applicable national codes.

177
174
215 279 241 279 215
1,004 Gravity point

590
1,230

76, Seongsan-dong, Changwon City, Gyeongnam,


641-713, Korea CHASSIS CODE: BR
4. Piping Diagrams
BG, BR Chassis
:Cooling
Heat Exchanger EEV :Heating
Filter

Th3 Th2
Sirocco Fan Filter

Th1 lndoor unit

Indoor Units
Refrigerant pipe connection port diameter
[Unit: mm(inch)]

MODEL GAS LIQUID


ARNU12GBGA2 Ø15.88(5/8) Ø9.52(3/8)
ARNU15GBGA2 Ø15.88(5/8) Ø9.52(3/8)
ARNU18GBGA2 Ø15.88(5/8) Ø9.52(3/8)
ARNU24GBGA2 Ø15.88(5/8) Ø9.52(3/8)
ARNU28GBRA2 Ø15.88(5/8) Ø9.52(3/8)
ARNU36GBRA2 Ø15.88(5/8) Ø9.52(3/8)
ARNU42GBRA2 Ø15.88(5/8) Ø9.52(3/8)

LOC. Description
Th1 Room thermistor
Th2 Pipe in thermistor
Th3 Pipe out thermistor

Ceiling Concealed Duct(High Static)(2) _ 7


5. Wiring Diagrams
BG Chassis
Indoor Units

CONNECTOR NUMBER LOCATION POINT FUNCTION


CN-POWER AC Power supply AC Power line input for indoor controller
CN-MOTOR1 Fan motor output Motor output of BLDC
CN-MOTOR2 Fan motor output Motor output of BLDC
CN-D/PUMP Drain pump output AC output for drain pump
CN-COM Communication Connection between indoor and outdoor
CN-EEV EEV Output EEV Control output
CN-FLOAT Float switch input Float switch sensing
CN-PIPE/IN Suction pipe sensor Pipe in thermistor
CN-PIPE/OUT Discharge pipe sensor Pipe out thermistor
CN-ROOM Room sensor Room air thermistor
CN-REMO Remote controller Remote control line
CN-ZONE Zontroller Zone control line
CN-DISPLAY RF Remote controller RF Remote control line
CN-CC Dry contact Dry contact line
Dip Switch Setting Off On Remarks
SW3 GROUP Master Slave Group Control setting using Wired Remote Controller
Old Dry Contact Mode Setting
1. Variable : Auto/Manual Mode can be chosen by Wide wired
SW4 DRY CONTACT Variable Auto remote controller or Wireless remote controller
(When shipped from Factory ’ Manual Mode)
2. Auto : For Dry Contact, it is always Auto mode.
1. Duct model
-. OFF : Default(not operate continuosly )
-. ON : Fan operate continuosly
SW5 EXTRA 1 Off On 2. Cassette Model : No Function
3. Ceiling Suspended Model
-. OFF : Ceiling(default)
-. ON : Floor

CAUTION
For Multi V Model, Dip Switch 1,2,6,7,8 must be set OFF
That dip switch is used for the other model.

8 _ Ceiling Concealed Duct(High Static)(2)


5. Wiring Diagrams
BR Chassis

Indoor Units
CONNECTOR NUMBER LOCATION POINT FUNCTION
CN-POWER AC Power supply AC Power line input for indoor controller
CN-MOTOR1 Fan motor output Motor output of BLDC
CN-MOTOR2 Fan motor output Motor output of BLDC
CN-D/PUMP Drain pump output AC output for drain pump
CN-COM Communication Connection between indoor and outdoor
CN-EEV EEV Output EEV Control output
CN-FLOAT Float switch input Float switch sensing
CN-PIPE/IN Suction pipe sensor Pipe in thermistor
CN-PIPE/OUT Discharge pipe sensor Pipe out thermistor
CN-ROOM Room sensor Room air thermistor
CN-REMO Remote controller Remote control line
CN-ZONE Zontroller Zone control line
CN-DISPLAY RF Remote controller RF Remote control line
CN-CC Dry contact Dry contact line
Dip Switch Setting Off On Remarks
SW3 GROUP Master Slave Group Control setting using Wired Remote Controller
Old Dry Contact Mode Setting
1. Variable : Auto/Manual Mode can be chosen by Wide wired
SW4 DRY CONTACT Variable Auto remote controller or Wireless remote controller
(When shipped from Factory ’ Manual Mode)
2. Auto : For Dry Contact, it is always Auto mode.
1. Duct model
-. OFF : Default(not operate continuosly )
-. ON : Fan operate continuosly
SW5 EXTRA 1 Off On 2. Cassette Model : No Function
3. Ceiling Suspended Model
-. OFF : Ceiling(default)
-. ON : Floor

CAUTION
For Multi V Model, Dip Switch 1,2,6,7,8 must be set OFF
That dip switch is used for the other model.

Ceiling Concealed Duct(High Static)(2) _ 9


6. Capacity Tables
6.1 Cooling Capacity Cooling capacity

Indoor air temp. (DB/WB, °C)


Capacity Outdoor 20 23 26 27 28 30 32
Index air temp. 14 16 18 19 20 22 24
(DB, °C) TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10 2.4 2.3 2.9 2.5 3.3 2.7 3.6 2.8 3.9 2.9 4.3 3.0 4.7 3.0
12 2.4 2.3 2.9 2.5 3.3 2.7 3.6 2.8 3.9 2.9 4.3 3.0 4.7 3.0
14 2.4 2.3 2.9 2.5 3.3 2.7 3.6 2.8 3.9 2.9 4.3 3.0 4.6 2.9
16 2.4 2.3 2.9 2.5 3.3 2.7 3.6 2.8 3.9 2.9 4.3 3.0 4.6 2.9
18 2.4 2.3 2.9 2.5 3.3 2.7 3.6 2.8 3.9 2.9 4.3 3.0 4.5 2.9
20 2.4 2.3 2.9 2.5 3.3 2.7 3.6 2.8 3.9 2.9 4.3 3.0 4.4 2.8
21 2.4 2.3 2.9 2.5 3.3 2.7 3.6 2.8 3.9 2.9 4.3 3.0 4.4 2.8
23 2.4 2.3 2.9 2.5 3.3 2.7 3.6 2.8 3.9 2.9 4.3 3.0 4.3 2.7
3.6 25 2.4 2.3 2.9 2.5 3.3 2.7 3.6 2.8 3.9 2.9 4.3 3.0 4.3 2.7
27 2.4 2.3 2.9 2.5 3.3 2.7 3.6 2.8 3.9 2.9 4.2 2.9 4.2 2.7
29 2.4 2.3 2.9 2.5 3.3 2.7 3.6 2.8 3.9 2.9 4.1 2.9 4.2 2.6
31 2.4 2.3 2.9 2.5 3.3 2.7 3.6 2.8 3.9 2.9 4.1 2.8 4.1 2.6
Indoor Units

33 2.4 2.3 2.9 2.5 3.3 2.7 3.6 2.8 3.9 2.9 4.0 2.8 4.0 2.5
35 2.4 2.3 2.9 2.5 3.3 2.7 3.6 2.8 3.9 2.9 3.9 2.7 4.0 2.5
37 2.4 2.3 2.9 2.5 3.3 2.7 3.6 2.8 3.8 2.8 3.8 2.7 3.9 2.5
39 2.4 2.3 2.9 2.5 3.3 2.7 3.6 2.8 3.7 2.7 3.8 2.6 3.9 2.4
10 3.0 2.9 3.6 3.2 4.2 3.4 4.5 3.5 4.8 3.6 5.4 3.8 5.9 3.7
12 3.0 2.9 3.6 3.2 4.2 3.4 4.5 3.5 4.8 3.6 5.4 3.8 5.8 3.7
14 3.0 2.9 3.6 3.2 4.2 3.4 4.5 3.5 4.8 3.6 5.4 3.8 5.8 3.6
16 3.0 2.9 3.6 3.2 4.2 3.4 4.5 3.5 4.8 3.6 5.4 3.8 5.7 3.6
18 3.0 2.9 3.6 3.2 4.2 3.4 4.5 3.5 4.8 3.6 5.4 3.8 5.6 3.6
20 3.0 2.9 3.6 3.2 4.2 3.4 4.5 3.5 4.8 3.6 5.4 3.8 5.5 3.5
21 3.0 2.9 3.6 3.2 4.2 3.4 4.5 3.5 4.8 3.6 5.4 3.8 5.5 3.5
23 3.0 2.9 3.6 3.2 4.2 3.4 4.5 3.5 4.8 3.6 5.4 3.8 5.4 3.4
4.5 25 3.0 2.9 3.6 3.2 4.2 3.4 4.5 3.5 4.8 3.6 5.3 3.7 5.3 3.4
27 3.0 2.9 3.6 3.2 4.2 3.4 4.5 3.5 4.8 3.6 5.2 3.6 5.3 3.4
29 3.0 2.9 3.6 3.2 4.2 3.4 4.5 3.5 4.8 3.6 5.1 3.6 5.2 3.3
31 3.0 2.9 3.6 3.2 4.2 3.4 4.5 3.5 4.8 3.6 5.1 3.5 5.1 3.2
33 3.0 2.9 3.6 3.2 4.2 3.4 4.5 3.5 4.8 3.6 4.9 3.5 5.0 3.2
35 3.0 2.9 3.6 3.2 4.2 3.4 4.5 3.5 4.8 3.6 4.9 3.4 4.9 3.2
37 3.0 2.9 3.6 3.2 4.2 3.4 4.5 3.5 4.7 3.5 4.8 3.4 4.9 3.1
39 3.0 2.9 3.6 3.2 4.2 3.4 4.5 3.5 4.6 3.4 4.7 3.3 4.8 3.0
10 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 6.0 4.2 6.7 4.4 7.4 4.4
12 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 6.0 4.2 6.7 4.4 7.3 4.3
14 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 6.0 4.2 6.7 4.4 7.2 4.3
16 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 6.0 4.2 6.7 4.4 7.1 4.2
18 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 6.0 4.2 6.7 4.4 7.0 4.1
20 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 6.0 4.2 6.7 4.4 6.9 4.1
21 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 6.0 4.2 6.7 4.4 6.8 4.1
23 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 6.0 4.2 6.7 4.4 6.7 4.0
5.6 25 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 6.0 4.2 6.6 4.3 6.6 3.9
27 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 6.0 4.2 6.4 4.2 6.6 3.9
29 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 6.0 4.2 6.4 4.2 6.5 3.8
31 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 6.0 4.2 6.3 4.1 6.4 3.8
33 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 6.0 4.2 6.2 4.0 6.3 3.7
35 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 6.0 4.2 6.0 4.0 6.2 3.6
37 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 5.8 4.1 5.9 3.9 6.1 3.6
39 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 5.7 4.0 5.8 3.8 6.0 3.5

10 _ Ceiling Concealed Duct(High Static) (2)


6. Capacity Tables
Cooling capacity

Indoor air temp. (DB/WB, °C)


Capacity Outdoor 20 23 26 27 28 30 32
Index air temp. 14 16 18 19 20 22 24
(DB, °C) TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 8.5 5.6 9.3 5.5
12 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 8.5 5.6 9.2 5.5
14 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 8.5 5.6 9.1 5.4
16 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 8.5 5.6 9.0 5.3
18 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 8.5 5.6 8.8 5.2
20 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 8.5 5.6 8.7 5.2
21 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 8.5 5.6 8.7 5.1
23 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 8.5 5.6 8.5 5.1
7.1 25 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 8.4 5.5 8.4 5.0
27 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 8.2 5.4 8.3 4.9
29 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 8.1 5.3 8.2 4.8
31 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 8.0 5.2 8.1 4.8

Indoor Units
33 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 7.8 5.1 7.9 4.7
35 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 7.7 5.0 7.8 4.6
37 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.4 5.2 7.5 4.9 7.7 4.6
39 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.2 5.1 7.4 4.8 7.6 4.5
10 5.5 5.0 6.6 5.5 7.7 6.0 8.2 6.1 8.7 6.2 9.8 6.5 10.8 6.5
12 5.5 5.0 6.6 5.5 7.7 6.0 8.2 6.1 8.7 6.2 9.8 6.5 10.6 6.4
14 5.5 5.0 6.6 5.5 7.7 6.0 8.2 6.1 8.7 6.2 9.8 6.5 10.5 6.3
16 5.5 5.0 6.6 5.5 7.7 6.0 8.2 6.1 8.7 6.2 9.8 6.5 10.4 6.2
18 5.5 5.0 6.6 5.5 7.7 6.0 8.2 6.1 8.7 6.2 9.8 6.5 10.2 6.1
20 5.5 5.0 6.6 5.5 7.7 6.0 8.2 6.1 8.7 6.2 9.8 6.5 10.1 6.0
21 5.5 5.0 6.6 5.5 7.7 6.0 8.2 6.1 8.7 6.2 9.8 6.5 10.0 6.0
23 5.5 5.0 6.6 5.5 7.7 6.0 8.2 6.1 8.7 6.2 9.8 6.5 9.9 5.9
8.2 25 5.5 5.0 6.6 5.5 7.7 6.0 8.2 6.1 8.7 6.2 9.7 6.4 9.7 5.8
27 5.5 5.0 6.6 5.5 7.7 6.0 8.2 6.1 8.7 6.2 9.4 6.3 9.6 5.8
29 5.5 5.0 6.6 5.5 7.7 6.0 8.2 6.1 8.7 6.2 9.3 6.2 9.5 5.7
31 5.5 5.0 6.6 5.5 7.7 6.0 8.2 6.1 8.7 6.2 9.2 6.1 9.3 5.6
33 5.5 5.0 6.6 5.5 7.7 6.0 8.2 6.1 8.7 6.2 9.0 6.0 9.2 5.5
35 5.5 5.0 6.6 5.5 7.7 6.0 8.2 6.1 8.7 6.2 8.9 5.9 9.0 5.4
37 5.5 5.0 6.6 5.5 7.7 6.0 8.2 6.1 8.5 6.1 8.7 5.8 8.9 5.3
39 5.5 5.0 6.6 5.5 7.7 6.0 8.2 6.1 8.4 6.0 8.5 5.7 8.8 5.3
10 7.2 6.4 8.5 7.1 9.9 7.7 10.6 7.8 11.3 8.1 12.7 8.4 13.9 8.4
12 7.2 6.4 8.5 7.1 9.9 7.7 10.6 7.8 11.3 8.1 12.7 8.4 13.7 8.2
14 7.2 6.4 8.5 7.1 9.9 7.7 10.6 7.8 11.3 8.1 12.7 8.4 13.6 8.2
16 7.2 6.4 8.5 7.1 9.9 7.7 10.6 7.8 11.3 8.1 12.7 8.4 13.4 8.0
18 7.2 6.4 8.5 7.1 9.9 7.7 10.6 7.8 11.3 8.1 12.7 8.4 13.2 7.9
20 7.2 6.4 8.5 7.1 9.9 7.7 10.6 7.8 11.3 8.1 12.7 8.4 13.0 7.8
21 7.2 6.4 8.5 7.1 9.9 7.7 10.6 7.8 11.3 8.1 12.7 8.4 12.9 7.8
23 7.2 6.4 8.5 7.1 9.9 7.7 10.6 7.8 11.3 8.1 12.7 8.4 12.8 7.7
10.6 25 7.2 6.4 8.5 7.1 9.9 7.7 10.6 7.8 11.3 8.1 12.5 8.3 12.6 7.5
27 7.2 6.4 8.5 7.1 9.9 7.7 10.6 7.8 11.3 8.1 12.2 8.1 12.4 7.5
29 7.2 6.4 8.5 7.1 9.9 7.7 10.6 7.8 11.3 8.1 12.1 8.0 12.2 7.3
31 7.2 6.4 8.5 7.1 9.9 7.7 10.6 7.8 11.3 8.1 11.9 7.9 12.0 7.2
33 7.2 6.4 8.5 7.1 9.9 7.7 10.6 7.8 11.3 8.1 11.7 7.8 11.8 7.1
35 7.2 6.4 8.5 7.1 9.9 7.7 10.6 7.8 11.3 8.1 11.4 7.6 11.7 7.0
37 7.2 6.4 8.5 7.1 9.9 7.7 10.6 7.8 11.0 7.9 11.2 7.5 11.5 6.9
39 7.2 6.4 8.5 7.1 9.9 7.7 10.6 7.8 10.8 7.7 11.0 7.3 11.3 6.8

Ceiling Concealed Duct(High Static) (2) _ 11


6. Capacity Tables

Cooling capacity

Indoor air temp. (DB/WB, °C)


Capacity Outdoor 20 23 26 27 28 30 32
Index air temp. 14 16 18 19 20 22 24
(DB, °C) TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10 8.3 7.5 9.9 8.3 11.5 9.0 12.3 9.1 13.1 9.4 14.7 9.8 16.2 9.7
12 8.3 7.5 9.9 8.3 11.5 9.0 12.3 9.1 13.1 9.4 14.7 9.8 15.9 9.6
14 8.3 7.5 9.9 8.3 11.5 9.0 12.3 9.1 13.1 9.4 14.7 9.8 15.8 9.5
16 8.3 7.5 9.9 8.3 11.5 9.0 12.3 9.1 13.1 9.4 14.7 9.8 15.6 9.3
18 8.3 7.5 9.9 8.3 11.5 9.0 12.3 9.1 13.1 9.4 14.7 9.8 15.3 9.2
20 8.3 7.5 9.9 8.3 11.5 9.0 12.3 9.1 13.1 9.4 14.7 9.8 15.1 9.1
21 8.3 7.5 9.9 8.3 11.5 9.0 12.3 9.1 13.1 9.4 14.7 9.8 15.0 9.0
23 8.3 7.5 9.9 8.3 11.5 9.0 12.3 9.1 13.1 9.4 14.7 9.8 14.8 8.9
12.3 25 8.3 7.5 9.9 8.3 11.5 9.0 12.3 9.1 13.1 9.4 14.5 9.7 14.6 8.8
27 8.3 7.5 9.9 8.3 11.5 9.0 12.3 9.1 13.1 9.4 14.1 9.4 14.4 8.6
Indoor Units

29 8.3 7.5 9.9 8.3 11.5 9.0 12.3 9.1 13.1 9.4 14.0 9.3 14.2 8.5
31 8.3 7.5 9.9 8.3 11.5 9.0 12.3 9.1 13.1 9.4 13.8 9.2 14.0 8.4
33 8.3 7.5 9.9 8.3 11.5 9.0 12.3 9.1 13.1 9.4 13.5 9.0 13.7 8.3
35 8.3 7.5 9.9 8.3 11.5 9.0 12.3 9.1 13.1 9.4 13.3 8.8 13.5 8.1
37 8.3 7.5 9.9 8.3 11.5 9.0 12.3 9.1 12.8 9.2 13.0 8.7 13.4 8.0
39 8.3 7.5 9.9 8.3 11.5 9.0 12.3 9.1 12.5 9.0 12.8 8.5 13.1 7.9

Notes:
TC: Total Capacity(kW), SHC: Sensible Heat Capacity(kW) 2. Refer to Capacity Correction Factor in the outdoor unit PDB for
1. Capacity tables show the representative value of conditions the actual performance data of each indoor unit and outdoor unit
which may occur. combination.

12 _ Ceiling Concealed Duct(High Static) (2)


6. Capacity Tables
6.2 Heating Capacity Heating capacity

Outdoor air Indoor air temp. (DB, °C)


Capacity temp. 16 18 20 21 22 24
Index TC TC TC TC TC TC
DB(°C) WB(°C)
kW kW kW kW kW kW
-24.8 -25.0 2.3 2.3 2.3 2.3 2.3 2.3
-21.8 -22.0 2.8 2.8 2.8 2.8 2.8 2.8
-19.8 -20.0 2.9 2.9 2.9 2.9 2.9 2.9
-18.8 -19.0 3.0 3.0 3.0 3.0 3.0 3.0
-16.7 -17.0 3.1 3.1 3.1 3.1 3.1 3.1
-14.7 -15.0 3.3 3.3 3.3 3.3 3.3 3.3
-12.6 -13.0 3.5 3.4 3.4 3.4 3.4 3.4
-10.5 -11.0 3.6 3.6 3.6 3.6 3.6 3.5
-9.5 -10.0 3.7 3.7 3.7 3.7 3.7 3.5
-8.5 -9.1 3.8 3.8 3.7 3.7 3.7 3.5
3.6 -7.0 -7.6 3.9 3.9 3.9 3.8 3.7 3.5
-5.0 -5.6 4.0 4.0 4.0 3.9 3.7 3.5
-3.0 -3.7 4.2 4.1 4.0 3.9 3.7 3.5
0.0 -0.7 4.3 4.1 4.0 3.9 3.7 3.5
3.0 2.2 4.4 4.3 4.0 3.9 3.7 3.5

Indoor Units
5.0 4.1 4.5 4.3 4.0 3.9 3.7 3.5
7.0 6.0 4.5 4.3 4.0 3.9 3.7 3.5
9.0 7.9 4.5 4.3 4.0 3.9 3.7 3.5
11.0 9.8 4.5 4.3 4.0 3.9 3.7 3.5
13.0 11.8 4.5 4.3 4.0 3.9 3.7 3.5
15.0 13.7 4.5 4.3 4.0 3.9 3.7 3.5
-24.8 -25.0 2.9 2.9 2.9 2.9 2.9 2.9
-21.8 -22.0 3.5 3.5 3.5 3.5 3.5 3.5
-19.8 -20.0 3.7 3.7 3.7 3.7 3.7 3.6
-18.8 -19.0 3.8 3.7 3.7 3.7 3.7 3.7
-16.7 -17.0 3.9 3.9 3.9 3.9 3.9 3.9
-14.7 -15.0 4.1 4.1 4.1 4.1 4.1 4.1
-12.6 -13.0 4.3 4.3 4.3 4.3 4.3 4.3
-10.5 -11.0 4.5 4.5 4.5 4.5 4.5 4.4
-9.5 -10.0 4.6 4.6 4.6 4.6 4.6 4.4
-8.5 -9.1 4.7 4.7 4.7 4.7 4.7 4.4
4.5 -7.0 -7.6 4.8 4.8 4.8 4.8 4.7 4.4
-5.0 -5.6 5.0 5.0 5.0 4.8 4.7 4.4
-3.0 -3.7 5.3 5.1 5.0 4.8 4.7 4.4
0.0 -0.7 5.3 5.2 5.0 4.8 4.7 4.4
3.0 2.2 5.5 5.3 5.0 4.8 4.7 4.4
5.0 4.1 5.6 5.3 5.0 4.8 4.7 4.4
7.0 6.0 5.6 5.3 5.0 4.8 4.7 4.4
9.0 7.9 5.6 5.3 5.0 4.8 4.7 4.4
11.0 9.8 5.6 5.3 5.0 4.8 4.7 4.4
13.0 11.8 5.6 5.3 5.0 4.8 4.7 4.4
15.0 13.7 5.6 5.3 5.0 4.8 4.7 4.4
-24.8 -25.0 3.6 3.6 3.6 3.6 3.6 3.6
-21.8 -22.0 4.4 4.4 4.4 4.4 4.4 4.4
-19.8 -20.0 4.6 4.6 4.6 4.6 4.6 4.6
-18.8 -19.0 4.8 4.7 4.7 4.7 4.7 4.7
-16.7 -17.0 5.0 5.0 5.0 4.9 4.9 4.9
-14.7 -15.0 5.2 5.2 5.2 5.2 5.2 5.2
-12.6 -13.0 5.5 5.4 5.4 5.4 5.4 5.4
-10.5 -11.0 5.7 5.7 5.7 5.7 5.7 5.5
-9.5 -10.0 5.8 5.8 5.8 5.8 5.8 5.5
-8.5 -9.1 5.9 5.9 5.9 5.9 5.9 5.5
-7.0 -7.6 6.1 6.1 6.1 6.0 5.9 5.5
5.6 -5.0 -5.6 6.3 6.3 6.3 6.1 5.9 5.5
-3.0 -3.7 6.6 6.5 6.3 6.1 5.9 5.5
0.0 -0.7 6.7 6.5 6.3 6.1 5.9 5.5
3.0 2.2 6.9 6.7 6.3 6.1 5.9 5.5
5.0 4.1 7.0 6.7 6.3 6.1 5.9 5.5
7.0 6.0 7.1 6.7 6.3 6.1 5.9 5.5
9.0 7.9 7.1 6.7 6.3 6.1 5.9 5.5
11.0 9.8 7.1 6.7 6.3 6.1 5.9 5.5
13.0 11.8 7.1 6.7 6.3 6.1 5.9 5.5
15.0 13.7 7.1 6.7 6.3 6.1 5.9 5.5

Ceiling Concealed Duct(High Static) (2) _ 13


6. Capacity Tables
Heating capacity

Outdoor air Indoor air temp. (DB, °C)


Capacity temp. 16 18 20 21 22 24
Index TC TC TC TC TC TC
DB(°C) WB(°C)
kW kW kW kW kW kW
-24.8 -25.0 4.6 4.6 4.6 4.6 4.6 4.6
-21.8 -22.0 5.6 5.6 5.6 5.6 5.6 5.5
-19.8 -20.0 5.9 5.9 5.9 5.9 5.9 5.8
-18.8 -19.0 6.0 6.0 6.0 6.0 6.0 6.0
-16.7 -17.0 6.3 6.3 6.3 6.3 6.3 6.3
-14.7 -15.0 6.6 6.6 6.6 6.6 6.6 6.6
-12.6 -13.0 6.9 6.9 6.9 6.9 6.9 6.9
-10.5 -11.0 7.2 7.2 7.2 7.2 7.2 7.0
-9.5 -10.0 7.4 7.4 7.3 7.3 7.3 7.0
-8.5 -9.1 7.5 7.5 7.5 7.5 7.5 7.0
-7.0 -7.6 7.7 7.7 7.7 7.7 7.5 7.0
7.1 -5.0 -5.6 8.0 8.0 8.0 7.7 7.5 7.0
-3.0 -3.7 8.4 8.2 8.0 7.7 7.5 7.0
0.0 -0.7 8.6 8.3 8.0 7.7 7.5 7.0
3.0 2.2 8.8 8.5 8.0 7.7 7.5 7.0
Indoor Units

5.0 4.1 8.9 8.5 8.0 7.7 7.5 7.0


7.0 6.0 9.0 8.5 8.0 7.7 7.5 7.0
9.0 7.9 9.0 8.5 8.0 7.7 7.5 7.0
11.0 9.8 9.0 8.5 8.0 7.7 7.5 7.0
13.0 11.8 9.0 8.5 8.0 7.7 7.5 7.0
15.0 13.7 9.0 8.5 8.0 7.7 7.5 7.0
-24.8 -25.0 5.3 5.3 5.3 5.3 5.3 5.3
-21.8 -22.0 6.4 6.4 6.4 6.4 6.4 6.4
-19.8 -20.0 6.8 6.8 6.7 6.7 6.7 6.7
-18.8 -19.0 6.9 6.9 6.9 6.9 6.9 6.9
-16.7 -17.0 7.2 6.9 7.2 7.2 7.2 7.2
-14.7 -15.0 7.6 6.9 7.6 7.6 7.6 7.5
-12.6 -13.0 8.0 6.9 7.9 7.9 7.9 7.9
-10.5 -11.0 8.3 6.9 8.3 8.3 8.3 8.0
-9.5 -10.0 8.5 6.9 8.4 8.4 8.4 8.0
-8.5 -9.1 8.6 6.9 8.6 8.6 8.6 8.0
8.2 -7.0 -7.6 8.9 6.9 8.9 8.8 8.6 8.0
-5.0 -5.6 9.2 6.9 9.2 8.9 8.6 8.0
-3.0 -3.7 9.7 6.9 9.2 8.9 8.6 8.0
0.0 -0.7 9.8 6.9 9.2 8.9 8.6 8.0
3.0 2.2 10.1 6.9 9.2 8.9 8.6 8.0
5.0 4.1 10.3 6.9 9.2 8.9 8.6 8.0
7.0 6.0 10.4 6.9 9.2 8.9 8.6 8.0
9.0 7.9 10.4 6.9 9.2 8.9 8.6 8.0
11.0 9.8 10.4 6.9 9.2 8.9 8.6 8.0
13.0 11.8 10.4 6.9 9.2 8.9 8.6 8.0
15.0 13.7 10.4 6.9 9.2 8.9 8.6 8.0
-24.8 -25.0 6.9 6.9 6.8 6.8 6.8 6.8
-21.8 -22.0 8.3 8.3 8.3 8.3 8.3 8.2
-19.8 -20.0 8.8 8.8 8.7 8.7 8.7 8.6
-18.8 -19.0 9.0 8.9 8.9 8.9 8.9 8.9
-16.7 -17.0 9.4 9.4 9.4 9.3 9.3 9.3
-14.7 -15.0 9.9 9.9 9.8 9.8 9.8 9.8
-12.6 -13.0 10.3 10.3 10.3 10.3 10.2 10.2
-10.5 -11.0 10.8 10.8 10.7 10.7 10.7 10.4
-9.5 -10.0 11.0 11.0 10.9 10.9 10.9 10.4
-8.5 -9.1 11.2 11.2 11.1 11.1 11.1 10.4
-7.0 -7.6 11.5 11.5 11.5 11.4 11.1 10.4
10.6 -5.0 -5.6 12.0 11.9 11.9 11.5 11.1 10.4
-3.0 -3.7 12.5 12.2 11.9 11.5 11.1 10.4
0.0 -0.7 12.7 12.3 11.9 11.5 11.1 10.4
3.0 2.2 13.1 12.7 11.9 11.5 11.1 10.4
5.0 4.1 13.3 12.7 11.9 11.5 11.1 10.4
7.0 6.0 13.4 12.7 11.9 11.5 11.1 10.4
9.0 7.9 13.4 12.7 11.9 11.5 11.1 10.4
11.0 9.8 13.4 12.7 11.9 11.5 11.1 10.4
13.0 11.8 13.4 12.7 11.9 11.5 11.1 10.4
15.0 13.7 13.4 12.7 11.9 11.5 11.1 10.4

14 _ Ceiling Concealed Duct(High Static) (2)


6. Capacity Tables
Heating capacity

Outdoor air Indoor air temp. (DB, °C)


Capacity temp. 16 18 20 21 22 24
Index TC TC TC TC TC TC
DB(°C) WB(°C)
kW kW kW kW kW kW
-24.8 -25.0 8.0 8.0 7.9 7.9 7.9 7.9
-21.8 -22.0 9.7 9.7 9.6 9.6 9.6 9.5
-19.8 -20.0 10.2 10.2 10.1 10.1 10.1 10.0
-18.8 -19.0 10.4 10.3 10.3 10.3 10.3 10.3
-16.7 -17.0 10.9 10.9 10.9 10.8 10.8 10.8
-14.7 -15.0 11.4 11.4 11.4 11.4 11.4 11.3
-12.6 -13.0 12.0 11.9 11.9 11.9 11.8 11.8
-10.5 -11.0 12.5 12.5 12.4 12.4 12.4 12.0
-9.5 -10.0 12.7 12.7 12.7 12.7 12.7 12.0
-8.5 -9.1 13.0 13.0 12.9 12.9 12.9 12.0
-7.0 -7.6 13.3 13.3 13.3 13.2 12.9 12.0
12.3 -5.0 -5.6 13.9 13.8 13.8 13.4 12.9 12.0
-3.0 -3.7 14.5 14.2 13.8 13.4 12.9 12.0
0.0 -0.7 14.8 14.3 13.8 13.4 12.9 12.0
3.0 2.2 15.2 14.7 13.8 13.4 12.9 12.0

Indoor Units
5.0 4.1 15.4 14.7 13.8 13.4 12.9 12.0
7.0 6.0 15.6 14.7 13.8 13.4 12.9 12.0
9.0 7.9 15.6 14.7 13.8 13.4 12.9 12.0
11.0 9.8 15.6 14.7 13.8 13.4 12.9 12.0
13.0 11.8 15.6 14.7 13.8 13.4 12.9 12.0
15.0 13.7 15.6 14.7 13.8 13.4 12.9 12.0

Notes:
TC: Total Capacity(kW) 3. In accordance with operation limits of outdoor unit, applicable range of
1. Capacity tables show the representative value of conditions which may occur. capacity tables is different.
2. is shown as reference. When selecting the outdoor units, avoid the 4. Refer to Capacity Correction Factor in the outdoor unit PDB for the actual
outdoor air temperature range shown by . performance data of each indoor unit and outdoor unit combination.

Ceiling Concealed Duct(High Static) (2) _ 15


7. External Static Pressure (E.S.P) & Air Flow
ARNU12GBGA2, ARNU15GBGA2, ARNU18GBGA2, ARNU24GBGA2
(Unit: CMM)
Setting Static Pressure(mmAq(Pa))
Value 3(29) 4(39) 5(49) 6(59) 7(69) 8(78) 9(88) 10(98) 12(118) 14(137) 16(157) 18(177)
70 9.6 5.2 - - - - - - - - - -
80 14.4 10.6 4.0 - - - - - - - - -
90 18.6 14.2 12.1 9.3 4.1 - - - - - - -
100 22.3 20.3 17.0 13.5 11.0 6.2 4.2 - - - - -
110 26.3 24.2 21.4 18.6 17.5 13.8 11.6 6.6 - - - -
120 29.7 27.5 25.6 24.0 21.8 19.0 17.9 14.6 12.1 - - -
130 33.4 31.2 30.0 28.5 26.9 25.3 23.4 21.8 18.1 14.6 11.3 -
140 37.3 36.0 35.0 32.1 30.4 29.0 27.4 25.9 21.6 17.8 14.5 9.4
143 38.2 37.5 36.1 33.9 32.1 30.7 28.8 27.2 23.0 20.1 16.8 12.5
150 41.0 40.7 38.5 38.0 36.0 34.5 32.1 30.1 26.3 22.4 18.2 15.8
160 - - - - 38.2 36.1 35.0 34.6 31.1 26.8 23.3 19.3
Indoor Units

ARNU28GBRA2, ARNU36GBRA2, ARNU42GBRA2


(Unit: CMM)
Static Pressure(mmAq(Pa))
Setting Value
5(49) 6(59) 8(78) 10(98) 12(118) 14(137) 15(147) 16(157) 17(168) 18(176) 20(196)
91 46.5 43.7 38.2 31.3 23.2 14.0 9.0 3.7 - - -
96 49.9 46.1 43.0 33.5 31.1 18.4 13.7 9.0 2.6 - -
101 52.1 50.2 47.9 39.5 37.4 27.3 25.2 17.8 8.9 6.1 -
106 51.4 51.2 50.4 44.4 43.1 33.3 32.1 28.9 21.0 17.9 8.3
111 53.6 53.7 52.9 49.9 48.3 40.6 40.2 32.8 31.5 27.2 17.5
116 - - - 55.7 50.8 44.8 42.6 40.1 37.6 32.5 27.6
121 - - - - 52.2 50.8 50.3 45.7 44.6 38.8 32.2
126 - - - - - - 54.4 51.2 50.4 46.0 43.5

Note: 1. The above table shows the correlation between the air rates and E.S.P.
2. The above table shows the available E.S.P. range.
3. If the E.S.P. of the installed indoor is less than the lowest value(as mention in the table), indoor components
can be failed.

16 _ Ceiling Concealed Duct(High Static)(2)


7. External Static Pressure (E.S.P) & Air Flow
ARNU12GBGA2, ARNU15GBGA2, ARNU18GBGA2, ARNU24GBGA2
Capacity Mode Set value Standard CMM Lower Limit of External Upper Limit of External
ESP(mmAq(Pa)) Static Pressure(mmAq(Pa)) Static Pressure(mmAq(Pa))
HI 100 13.5(477)
High
Mid 96 6(59) 12.1(427) 6(59) 12(118)
(factory set)
Low 93 9.4(332)
12k
HI 95 16.6(586)
Standard Mid 92 4(39) 15.1(533) 4(39) 8(78)
Low 89 13.7(483)
HI 110 13.8(487)
High
Mid 106 8(78) 11.8(417) 8(78) 18(177)
(factory set)
Low 103 9.5(336)
15k
HI 100 13.5(477)
Standard Mid 94 6(59) 12.1(427) 6(59) 10(98)
Low 89 9.0(318)
HI 113 15.2(537)
High
Mid 110 8(78) 13.8(487) 8(78) 18(177)
(factory set)
Low 106 11.8(417)

Indoor Units
18k
HI 102 15.5(547)
Standard Mid 98 6(59) 13.3(470) 6(59) 10(98)
Low 94 12.1(427)
HI 120 19.0(671)
High
Mid 113 8(78) 15.2(537) 8(78) 18(177)
(factory set)
Low 110 13.8(487)
24k
HI 112 19.0(671)
Standard Mid 104 6(59) 16.3(576) 6(59) 10(98)
Low 102 15.5(547)

ARNU28GBRA2, ARNU36GBRA2, ARNU42GBRA2


Capacity Mode Set value Standard CMM Lower Limit of External Upper Limit of External
ESP(mmAq(Pa)) Static Pressure(mmAq(Pa)) Static Pressure(mmAq(Pa))
HI 108 36.2(1,278)
High
Mid 105 14(137) 32.1(1,134) 10(98) 20(196)
(factory set)
Low 102 28.5(1,007)
28k
HI 94 32.6(1,151)
Standard Mid 91 10(98) 31.3(1,105) 7(67) 14(137)
Low 89 30.4(1,074)
HI 110 39.1(1,381)
High
Mid 106 14(137) 33.3(1,176) 10(98) 20(196)
(factory set)
Low 103 29.7(1,049)
36k
HI 102 40.5(1,430)
Standard Mid 94 10(98) 32.6(1,151) 7(67) 14(137)
Low 91 31.3(1,105)
HI 113 42.2(1,490)
High
Mid 110 14(137) 39.1(1,381) 10(98) 20(196)
(factory set)
Low 106 33.3(1,176)
42k
HI 104 42.4(1,497)
Standard Mid 102 10(98) 40.5(1,430) 7(67) 14(137)
Low 94 32.6(1,151)
Note:
1.The above table shows the available E.S.P. range.
2. The air flow of above model is increased by 20% depending on the Mode setting.
3. Above models are developed for high efficiency and high sensible heat.
If you want to use Zone control, you have to set ESP Value.

Ceiling Concealed Duct(High Static)(2) _ 17


8. Electric Characteristics

Unit Power Supply IFM Input(W)


Voltage
Model Type Hz Volts MCA MFA kW FLA cooling Heating
Range
ARNU12GBGA2 BG 3.31 15 0.35 2.65 450 450
ARNU15GBGA2 BG 3.31 15 0.35 2.65 450 450
ARNU18GBGA2 BG 3.31 15 0.35 2.65 450 450
Max:264
ARNU24GBGA2 BG 50 220-240 3.31 15 0.35 2.65 450 450
Min:198
ARNU28GBRA2 BR 3.45 15 0.37 2.76 450 450
ARNU36GBRA2 BR 3.45 15 0.37 2.76 450 450
ARNU42GBRA2 BR 3.45 15 0.37 2.76 450 450
ARNU12GBGA2 BG 3.31 15 0.35 2.65 450 450
ARNU15GBGA2 BG 3.31 15 0.35 2.65 450 450
ARNU18GBGA2 BG 3.31 15 0.35 2.65 450 450
Max:242
ARNU24GBGA2 BG 60 220 3.31 15 0.35 2.65 450 450
Min:198
ARNU28GBRA2 BR 3.45 15 0.37 2.76 450 450
Indoor Units

ARNU36GBRA2 BR 3.45 15 0.37 2.76 450 450


ARNU42GBRA2 BR 3.45 15 0.37 2.76 450 450

Symbols: Note :
MCA : Min, Circuit Amps(A) 1. Voltage range
MFA : Max. Fuse Amps(see note 5) Units are suitable for use on electrical systems where voltage
kW : Fan Motor Rated Output(kW) supplied to unit terminals is not below or above the listed range
FLA : Full Load Amps(A) limits,
IFM : Indoor Fan Motor 2. Maximum allowable voltage unbalance between phases is 2%
3. MCA/MFA
MCA=1.25 x FLA
MFA≤ 4 x FLA
(Next lower standard fuse rating. Min. 15A)
4. Select wire size based on the MCA
5. Instead of fuse, use Circuit Breaker.

18 _ Ceiling Concealed Duct(High Static)(2)


9. Sound Levels
Overall
Notes:
1. Sound measured at 1.5m away from the center of the unit
DISCHARGE SUCTION 2. Operating condition
- Power source : 220-240V 50Hz / 220V 60Hz
DUCT DUCT
- Cooling : Indoor temperature (27°C DB, 19°C WB),
Outdoor temperature (35°C DB, 24°C WB)
1.5m - Heating : Indoor temperature (20°C DB, 15°C WB),
2m 2m Outdoor temperature (7°C DB, 6°C WB)
- External static pressure is according to “Standard mode”
value. Refer the specifications.
3. Reference accoustic pressure 0dB = 20μPa
❈ Measuring place : Anechoic chamber 4. Sound level will vary depending on a range of factors such as
the construction(acoustic absorption coefficient) of particular
room in which the equipment in installed.

Sound Level dB(A) Sound Level dB(A)

Indoor Units
Model Model
H M L H M L
ARNU12GBGA2 32 31 30 ARNU28GBRA2 41 40 39
ARNU15GBGA2 33 32 31 ARNU36GBRA2 42 41 40
ARNU18GBGA2 33 32 31 ARNU42GBRA2 43 42 41
ARNU24GBGA2 36 35 33

Sound Pressure Level


ARNU15GBGA2
ARNU12GBGA2 ARNU18GBGA2 ARNU24GBGA2
80 80 80

n High n High n High


▲ Mid ▲ Mid ▲ Mid
70 ● Low 70 ● Low 70 ● Low
Octave Band Sound Pressure Level (0dB = 20μPa)

Octave Band Sound Pressure Level (0dB = 20μPa)

Octave Band Sound Pressure Level (0dB = 20μPa)

NC-65 NC-65 NC-65


60 60 60
NC-60 NC-60 NC-60

NC-55 NC-55 NC-55


50 50 50
NC-50 NC-50 NC-50

NC-45 NC-45 NC-45


40 40 40
NC-40 NC-40 NC-40

NC-35 NC-35 NC-35


30 30 30
NC-30 NC-30 NC-30

NC-25 NC-25 NC-25


20 20 20
Approximate Approximate Approximate
NC-20 NC-20 NC-20
Hearing Hearing Hearing
Threshold Threshold Threshold
NC-15 NC-15 NC-15
10 10 10
63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

Ceiling Concealed Duct(High Static)(2) _ 19


9. Sound Levels
ARNU28GBRA2 ARNU36GBRA2 ARNU42GBRA2
80 80 80

▲ High ▲ High ▲ High


n Mid n Mid n Mid
70
● Low 70
● Low 70
● Low
Octave Band Sound Pressure Level (0dB = 20μPa)

Octave Band Sound Pressure Level (0dB = 20μPa)

Octave Band Sound Pressure Level (0dB = 20μPa)


NC-65 NC-65 NC-65
60 60 60
NC-60 NC-60 NC-60

NC-55 NC-55 NC-55


50 50 50
NC-50 NC-50 NC-50

NC-45 NC-45 NC-45


40 40 40
NC-40 NC-40 NC-40

NC-35 NC-35 NC-35


30 30 30
NC-30 NC-30 NC-30

NC-25 NC-25 NC-25


20 20 20
Approximate Approximate Approximate
NC-20 NC-20 NC-20
Hearing Hearing Hearing
Threshold Threshold Threshold
NC-15 NC-15 NC-15
10 10 10
63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)
Indoor Units

20 _ Ceiling Concealed Duct(High Static)(2)


10. Installation
• Please read this instruction sheet completely before installing the product.
• When the power cord is damaged, replacement work shall be performed by authorized personnel only.
• Installation work must be performed in accordance with the national wiring standards by authorized personnel only.

Air outlet vents Air filters

Air intake vents


TEMP

Wired LCD Remote Control


Remote Controller

Required Parts Required Tools

Indoor Units
• Connecting cable • Level
• Pipes: Gas side • Screw driver
Liquid side • Electric drill
• Hanging Bolt • Hole core drill
(W 3/8 or M10 length 650mm)
• Flaring Tool set
• Insulated drain hose
• Torque Wrenches
• Additional Drain hose
• Hexagonal Wrench
• Gas-leak detector
• Thermometer

10.1 Selection of the best location


Install the air conditioner in the location that satisfies the
[600(23-5/8) x 600(23-5/8)]
following conditions.
• The place shall easily bear a load exceeding four times
the indoor unitʼs weight.
• The place shall be able to inspect the unit as the figure.
• The place where the unit shall be leveled.
• The place shall allow easy water drainage.
(Suitable dimension “H” is necessary to get a slope to
(39-3/8)
1000

drain as figure.) 600 600


[Unit: mm(inch)] (23-5/8) (23-5/8)
• The place shall easily connect with the outdoor unit.
• The place where the unit is not affected by an electrical
noise.
• The place where air circulation in the room will be good .
• There should not be any heat source or steam near the
unit.
• The servicing inspection hole in the ceiling should be as
large as the product H = 20(25/32) or more
• The selection of the servicing hole should be approved [Unit: mm(inch)]
by the customer

Ceiling Concealed Duct(High Static)(2) _ 21


10. Installation
10.2 Ceiling dimension and hanging BG/BR Chassis
A
bolt location B
n Installation of Unit
Install the unit above the ceiling correctly.

C
CASE 1

E
POSITION OF SUSPENSION BOLT

D
• Apply a joint-canvas between the unit and duct to absorb (G)

F
unnecessary vibration.
• Apply a filter Accessory at air return hole.
• Refer to the Dimensions.
(Unit:mm)

I
Dimension
A B C D E F (G) H I H
Chassis
Drainage hole
Indoor Units

BG 1232 1182 355 47 450 30 87 830 186


BR 1282 1230 477 56 590 30 120 1006 294

• Install the unit leaning to a drainage hole side as a figure


M10 Nut X4
for easy water drainage.
M10 washer X4

CASE 2 M10 washer X4


M10 Nut X8
POSITION OF CONSOLE BOLT

• A place where the unit will be leveled and that can sup-
port the weight of the unit.
• A place where the unit can withstand its vibration.
• A place where service can be easily performed.

NOTE:
• Throughly study the following installation locations:
1. In such places as restaurants and kitchens, considerable amount of oil steam and flour adhere to the fan, the fin of
the heat exchanger, resulting in heat exchange reduction, spraying, dispersing of water drops, etc.
In these cases, take the following actions:
• Make sure that the ventilation fan for smoke-collecting hood on a cooking table has sufficient capacity so that it
draws oily steam which should not flow into the suction of the air conditioner.
• Make enough distance from a cooking room to install the air conditioner in such a place where it may not suck in
oil steam.
2. Avoid installing air conditioner in such circumstances where cutting oil mist or iron powder is in suspension in facto-
ries, etc.
3. Avoid places where inflammable gas is generated, flows in, is stored or vented.
4. Avoid places where sulfurous acid gas or corrosive gas is generated.
5. Avoid places near high frequency generators.

22 _ Ceiling Concealed Duct(High Static)(2)


10. Installation
• Select and mark the position for fixing bolts. • Insert the set anchor and washer onto the suspen-
• Drill the hole for set anchor on the face of ceiling. sion bolts for locking the suspension bolts on the ceil-
ing.
• Mount the suspension bolts to the set anchor firmly.
• Secure the installation plates onto the suspension bolts (adjust
level roughly) using nuts, washers and spring washers.

Old building New building

1 Set anchor
2 Plate washer
3 Spring washer
CAUTION 4 Nut
5 Suspension
Tighten the nut and bolt to prevent unit falling. bolts

Indoor Units
10.3 Connecting Cables between Indoor Unit and Outdoor Unit
Connect the wires to the terminals on the control board individually according to the outdoor unit connection.
• Ensure that the color of the wires of outdoor unit and the terminal No. are the same as those of indoor unit respectively

[Type 1]

Terminal Block Indoor Terminal Block Indoor SODU B SODU A IDU B IDU A INT B INT A
1(L1) N(L2) 3 4

INDOOR POWER INPUT

[Type 2]
Terminal Block Indoor Terminal Block Indoor SODU IDU INTERNET DRY1 DRY2 GND 12V Outdoor
1(L1) N(L2) 3 4 Unit
B A - - B A - - - -

INDOOR POWER INPUT

WARNING
Make sure that the screws of the terminal are not loose.

Clamping of cables
1) Arrange 2 power cables on the control panel.
2) First, fasten the steel clamp with a screw to the inner boss of control panel.
3) For the cooling model, fix the other side of the clamp with a screw strongly. For the heat pump model, put the 0.75mm2
cable(thinner cable) on the clamp and tighten it with a plastic clamp to the other boss of the control panel.

Ceiling Concealed Duct(High Static)(2) _ 23


10. Installation
THERMAL INSULATION All thermal insulation must comply with local requirement.

INDOOR UNIT
BG/BR Chassis

Union for liquid pipe Thermal insulator for refrigerant pipe


(Local supply) Thermal insulator for
Refrigerant pipe and thermal
piping(Local supply)
insulator(Local supply)

Hose clamp for thermal insulator


(Local supply)
Overlap with thermal
Thermal insulator for refrigerant pipe insulator for piping.
(Local supply) Hose clamp for thermal insulator(Local supply)
Union for gas pipe
Make sure that there is no clearance here.
Indoor Units

10.4 Checking the Drainage


BG/BR Chassis
1) Checking the Drainage

1. Remove the Air Filter.

2. Check the drainage.


• Spray one or two glasses of water on the evapo-
rator.
• Ensure that water flows through drain hose of
indoor unit without any leakage.

24 _ Ceiling Concealed Duct(High Static)(2)


10. Installation
10.5 Indoor Unit Drain Piping Pipe clamp
Upward
routing
• Drain piping must have down-slope (1/50 to 1/100): be sure not to pro- not allowed
vide up-and-down slope to prevent reversal flow. Indoor unit
• During drain piping connection, be careful not to exert extra force on the
drain port on the indoor unit.
• The outside diameter of the drain connection on the indoor unit is 32mm. Maintenance
drain port
Piping material: Polyvinyl chloride pipe inner
diometes Ø 25mm and pipe fittings
• Be sure to install heat insulation on the drain piping. 1/50~1/100

Heat insulation material: Polyethylene foam with MAX 700mm

thickness more than 8 mm.

Drain test

Indoor Units
The air conditioner uses a drain pump to drain water.
Use the following procedure to test the drain pump operation:

Feed water Flexible drain hose


(accessory) • Connect the main drain pipe to the exterior and leave it pro-
Main visionally until the test comes to an end.
drain pipe • Feed water to the flexible drain hose and check the piping
for leakage.
Drain
Drain Pump port Glue the joint • Be sure to check the drain pump for normal operation and
noise when electrical wiring is complete.
Drain hose connection
Use the clip (accessory) • When the test is complete, connect the flexible drain hose to
the drain port on the indoor unit.

Drain pan

Hanger
Max 300mm distance Hanger Bracket
CAUTION 1~15m 1/50~1/100 slope
Metal
Max 700mm

The supplied flexible drain hose should not be strained. clamp


A strained hose may cause leakage of water.
Flexible drain hose
Insulation

Ceiling Concealed Duct(High Static)(2) _ 25


10. Installation
10.6 Ground drain piping
a) It is standard work practice to make connections to the main pipe from above. The pipe down from the
combination should be as large as possible.

Face the vent pipe opening facing downward to


keep foreign matter from penetrating the system

Face piping
downward
Indoor Units

Vent pipe

b) The pipe work should be kept as short as possible and the number of indoor units per group kept to a
minimum.

10.7 Use of an auxiliary drain hose(flexible)


a) To connect drain pipe to the drain socket on the indoor unit, an auxiliary flexible drain hose should be
used. auxiliary flexible drain hose allows that the drain pipe can be connected to the socket without break-
ing by excessive strain.

Auxiliary drain hose


Thermal insulation (drain pipe area)

Metal clamp

Metal clamp
Thermal insulation(bend area)

Drain pan

h Important points
- The drain pipe should be at least equal in size to that of the indoor unit.
- The drain pipe is thermally insulated to prevent the formation of condensation inside the pipe.
- The drain up mechanism should be fitted before the indoor unit is installed and when the electricity has
been connected some water should be added to the drain pan and the drain pump to check and see if it is
functioning correctly.
- All connections should be secure. (Special care is needed with PVC pipe)
- Insulate auxiliary drain hose with thermal insulation band.

26 _ Ceiling Concealed Duct(High Static)(2)


10. Installation

WIRED REMOTE CONTROLLER INSTALLATION


• Since the room temperature sensor is in the remote controller, the remote controller box should be installed in a place
away from direct sunlight, high humidity and direct supply of cold air to maintain proper space temperature.
Install the remote controller about 5ft(1.5m) above the floor in an area with good air circulation at an average tempera-
ture.
Do not install the remote controller where it can be affected by:
- Drafts, or dead spots behind doors and in corners.
- Hot or cold air from ducts.
- Radiant heat from sun or appliances.
- Concealed pipes and chimneys.
- Uncontrolled areas such as an outside wall behind the remote controller.
- This remote controller is equipped with a seven segment LED. display. For proper display of the remote controller
LED's, the remote controller should be installed properly as shown in Fig.1.
(The standard height is 1.2~1.5 m from floor level.)

Indoor Units
Remote Controller
TEMP
yes

no
TEMP

Remote Controller

no
TEMP
5feet
Remote
Controller

(1.5meters)

no

Fig.1 Typical locations for remote controller

Ceiling Concealed Duct(High Static)(2) _ 27


10. Installation
Standard Accessories
Washer for Clamp Insulation for
Name Drain hose Clamp metal (Other)
hanging backet (Tie Wrap) fitting

Quantity 1 EA 1 EA 8 EA 4 EA 1 SET

• Owner's manual
• Installation manual

Shape for gas pipe

for liquid pipe


Indoor Units

CAUTION
• Use only those accessories (Standard or optional) which have designated specifications.

28 _ Ceiling Concealed Duct(High Static)(2)


Indoor unit

Ceiling Concealed Duct(Low Static)


1. List of functions

2. Specifications

3. Dimensions & Gravity point

4. Piping Diagrams

5. Wiring Diagrams

6. Capacity Tables

7. External Static Pressure (E.S.P) & Air Flow

8. Electric Characteristics

9. Sound Levels

10. Installation

11. Accessories
1. List of functions
ARNU07GB1G2, ARNU09GB1G2, ARNU12GB1G2, ARNU15GB1G2,
ARNU18GB2G2, ARNU24GB2G2, ARNU05GL1G2, ARNU07GL1G2,
Category Function
ARNU09GL1G2, ARNU12GL2G2, ARNU15GL2G2, ARNU18GL2G2,
ARNU21GL3G2, ARNU24GL3G2
Air supply outlet 1
Airflow direction control(left & right) -
Airflow direction control(up & down) -
Auto swing(left & right) -
Auto swing(up & down) -
Air flow
Airflow steps(fan/cool/heat) 3/3/3
Chaos swing -
Chaos wind(auto wind) -
Jet cool(Power wind) -
Swirl wind -
Deodorizing filter X
Air purifying Plasma air purifier X
Prefilter(washable / anti-fungus) O
Drain pump O

Indoor Units
E.S.P. control O
Installation
Electric heater(operation) X
High ceiling operation -
Hot start O
Reliability Self diagnosis O
Soft dry operation O
Auto changeover O(Heat recovery)
Auto cleaning X
Auto operation(artificial intelligence) O(Heat pump or Cooling only)
Auto restart operation O
Child lock O
Convenience Forced operation -
Group control O
Sleep mode O
Timer(on/off) O
Timer(weekly) O
Two thermistor control O
Wide wired remote controller PQRCVSL0/PQRCVSL0QW
Deluxe wired remote controller PQRCUDS0(B/S)
Individual Simple wired remote controller PQRCVCL0Q(W)
control Wired remote controller(for hotel use) PQRCHCA0Q(W)
Wireless LCD remote control PQWRH(C)Q0FDB
Zone control -
CTIE -
Special Electro thermostat -
function kit Remote temperature sensor PQRSTA0
Group control wire PZCWRCG3
Dry contact PQDSA(1)/PQDSB(1)/PQDSBC/PQDSBNGCM1/PQDSBCGCD0

O : Applied X : Not applied – : No relation


Option : Model name & price are different according to options, and assembled in factory with main unit.
Accessory : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate
package.

Ceiling Concealed Duct(Low Static) _ 1


2. Specifications
Type Ceiling Concealed Duct (Low Static)
Model Unit ARNU07GB1G2 ARNU09GB1G2 ARNU12GB1G2
kW 2.2 2.8 3.6
Cooling Capacity kcal/h 1,900 2,400 3,100
Btu/h 7,500 9,600 12,300
kW 2.5 3.2 4.0
Heating Capacity kcal/h 2,200 2,800 3,400
Btu/h 8,500 10,900 13,600
Casing Galvanized Steel Plate Galvanized Steel Plate Galvanized Steel Plate
mm 820 x 190 x 575 820 x 190 x 575 820 x 190 x 575
Dimensions(WxHxD) Body
inch 32-9/32 x 7-15/32 x 22-5/8 32-9/32 x 7-15/32 x 22-5/8 32-9/32 x 7-15/32 x 22-5/8
Coil Rows x Columns x FPI 2 x 11 x 21 2 x 11 x 21 2 x 11 x 21
Face Area m2 0.16 0.16 0.16
Type Sirocco Fan Sirocco Fan Sirocco Fan
Motor Output x Number W 28 28 28
Running Current A 0.15 0.15 0.15
Air Flow Rate(H / M / L) CMM 8.5 / 7.5 / 6.5 9.5 / 8.5 / 7.5 10.5 / 9.5 / 8.5
Indoor Units

(High Mode-factory set) cfm 300 / 265 / 229 335 / 300 / 265 371 / 335 / 300
Fan External Static Pressure mmAq(Pa) 2(20) 2(20) 2(20)
Air Flow Rate(H / M / L) CMM 8.5 / 7.5 / 6.5 9.5 / 8.5 / 7.5 10.5 / 9.5 / 8.5
(Standard Mode) cfm 300 / 265 / 229 335 / 300 / 265 371 / 335 / 300
External Static Pressure mmAq(Pa) 0(0) 0(0) 0(0)
Drive Direct Direct Direct
Motor type BLDC BLDC BLDC
Temperature Control Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating
Sound Absorbing Thermal Insulation Material Foamed polystrene Foamed polystrene Foamed polystrene
Air Filter - - -
Safety Device Fuse Fuse Fuser
Liquid Side mm(inch) Ø6.35(1/4) Ø6.35(1/4) Ø6.35(1/4)
Pipe Connections Gas Side mm(inch) Ø12.7(1/2) Ø12.7(1/2) Ø12.7(1/2)
Drain Pipe(Internal Dia.) mm(inch) 25.4(1) 25.4(1) 25.4(1)
Net Weight kg(lbs) 21(46.3) 21(46.3) 21(46.3)
Noise Level(Sound Press, 1.5m, H / M / L) dB(A) 29 / 26 / 24 31 / 29 / 26 33 / 30 / 29
Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50
1, 220, 60 1, 220, 60 1, 220, 60
Refrigerant Control EEV EEV EEV
Power cable mm2 CV1.5 x 3C CV1.5 x 3C CV1.5 x 3C
Transmission cable mm2 CVV-SB 1.0~1.5 x 2C CVV-SB 1.0~1.5 x 2C CVV-SB 1.0~1.5 x 2C

Notes:-
Conversion Formula
1. Capacities are based on the following conditions:
Cooling • Indoor temp. 27°C[80.6°F]DB/ 19°C[66.2°F]WB kcal/h= kW x 860
• Outdoor temp. 35°C[95°F]DB/ 24°C[75.2°F]WB Btu/h = kW x 3412
• Interconnecting Piping Length 7.5m cfm = m3/min x 35.3
• Level Difference of Zero l/s = CMM x 1000/60
Heating • Indoor temp. 20°C[68°F]DB/ 15°C[59°F]WB
• Outdoor temp. 7°C[44.6°F]DB/ 6°C[42.8°F]WB
• Interconnecting Piping Length 7.5m
• Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve
6. Noise Level is High Mode
7. Anechoic chamber conversion value is measured at 1.5 m downward from unit centre.
The values depends on the ambient conditions and values are normally higher in actual operation.

2 _ Ceiling Concealed Duct(Low Static)


2. Specifications
Type Ceiling Concealed Duct (Low Static)
Model Unit
ARNU15GB1G2 ARNU18GB2G2 ARNU24GB2G2
kW 4.5 5.6 7.1
Cooling Capacity kcal/h
3,900 4,800 6,100
Btu/h
15,400 19,100 24,200
kW 5.0 6.3 8.0
Heating Capacity kcal/h
4,300 5,400 6,900
Btu/h
17,100 21,500 27,300
Casing Galvanized Steel Plate Galvanized Steel Plate Galvanized Steel Plate
mm 820 x 190 x 575 1,100 x 190 x 575 1,100 x 190 x 575
Dimensions(WxHxD) Body
inch 32-9/32 x 7-15/32 x 22-5/8 43-5/16 x 7-15/32 x 22-5/8 43-5/16 x 7-15/32 x 22-5/8
Coil Rows x Columns x FPI 2 x 11 x 21 3 x 10 x 18 3 x 10 x 18
Face Area m2 0.16 0.23 0.23
Type Sirocco Fan Sirocco Fan Sirocco Fan
Motor Output x Number W 28 76 76
Running Current A 0.15 0.38 0.38
Air Flow Rate(H / M / L) CMM 11.5 / 10.5 / 9.5 16.0 / 14.0 / 12.0 19.0 / 17.0 / 15.0
(High Mode-factory set) cfm 406 / 371 / 335 565 / 494 / 424 671 / 600 / 530

Indoor Units
Fan External Static Pressure mmAq(Pa) 2(20) 2(20) 2(20)
Air Flow Rate(H / M / L) CMM 11.5 / 10.5 / 9.5 16.0 / 14.0 / 12.0 19.0 / 17.0 / 15.0
(Standard Mode) cfm 406 / 371 / 335 565 / 494 / 424 671 / 600 / 530
External Static Pressure mmAq(Pa) 0(0) 0(0) 0(0)
Drive Direct Direct Direct
Motor type BLDC BLDC BLDC
Temperature Control Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating
Sound Absorbing Thermal Insulation Material Foamed polystrene Foamed polystrene Foamed polystrene
Air Filter - - -
Safety Device Fuse Fuse Fuse
Liquid Side mm(inch) Ø6.35(1/4) Ø6.35(1/4) Ø9.52(3/8)
Pipe Connections Gas Side mm(inch) Ø12.7(1/2) Ø12.7(1/2) Ø15.88(5/8)
Drain Pipe(Internal Dia.) mm(inch) 25.4(1) 25.4(1) 25.4(1)
Net Weight kg(lbs) 21(46.3) 26(57.3) 26(57.3)
Noise Level(Sound Press, 1.5m, H / M / L) dB(A) 34 / 33 / 31 40 / 37 / 34 43 / 40 / 37
Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50
1, 220, 60 1, 220, 60 1, 220, 60
Refrigerant Control EEV EEV EEV
Power cable mm2 CV1.5 x 3C CV1.5 x 3C CV1.5 x 3C
Transmission cable mm2 CVV-SB 1.0~1.5 x 2C CVV-SB 1.0~1.5 x 2C CVV-SB 1.0~1.5 x 2C

Notes:-
Conversion Formula
1. Capacities are based on the following conditions:
Cooling • Indoor temp. 27°C[80.6°F]DB/ 19°C[66.2°F]WB kcal/h= kW x 860
• Outdoor temp. 35°C[95°F]DB/ 24°C[75.2°F]WB Btu/h = kW x 3412
• Interconnecting Piping Length 7.5m cfm = m3/min x 35.3
• Level Difference of Zero l/s = CMM x 1000/60
Heating • Indoor temp. 20°C[68°F]DB/ 15°C[59°F]WB
• Outdoor temp. 7°C[44.6°F]DB/ 6°C[42.8°F]WB
• Interconnecting Piping Length 7.5m
• Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve
6. Noise Level is High Mode
7. Anechoic chamber conversion value is measured at 1.5 m downward from unit centre.
The values depends on the ambient conditions and values are normally higher in actual operation.

Ceiling Concealed Duct(Low Static) _ 3


2. Specifications
Type Ceiling Concealed Duct (Low Static)
Model Unit ARNU05GL1G2 ARNU07GL1G2 ARNU09GL1G2
kW 1.7 2.2 2.8
Cooling Capacity kcal/h 1,500 1,900 2,400
Btu/h 5,800 7,500 9,600
kW 1.9 2.5 3.2
Heating Capacity kcal/h 1,600 2,200 2,800
Btu/h 6,500 8,500 10,900
Casing Galvanized Steel Plate Galvanized Steel Plate Galvanized Steel Plate
mm 700 x 190 x 700 700 x 190 x 700 700 x 190 x 700
Dimensions(WxHxD) Body
inch 27-9/16 × 7-15/32 × 27-9/16 27-9/16 × 7-15/32 × 27-9/16 27-9/16 × 7-15/32 × 27-9/16
Coil Rows x Columns x FPI 2 x 11 x 14 2 x 11 x 14 2 x 11 x 14
Face Area m2 0.12 0.12 0.12
Type Sirocco Fan Sirocco Fan Sirocco Fan
Motor Output x Number W 19 x 1 19 x 1 19 x 1
Running Current A 0.4 0.4 0.4
Air Flow Rate(H / M / L) CMM 6.7 / 6.2 / 5.5 7.5 / 6.5 / 5.5 9.0 / 7.0 / 5.5
(High Mode-factory set) cfm 240 / 220 / 200 270 / 230 / 200 320 / 250 / 200
Indoor Units

Fan External Static Pressure mmAq(Pa) 2.54 (25) 2.54 (25) 2.54 (25)
Air Flow Rate(H / M / L) CMM 6.7 / 6.2 / 5.5 7.5 / 6.5 / 5.5 9.0 / 7.0 / 5.5
(Standard Mode) cfm 240 / 220 / 200 270 / 230 / 200 320 / 250 / 200
External Static Pressure mmAq(Pa) 0 (0) 0 (0) 0 (0)
Drive Direct Direct Direct
Motor type BLDC BLDC BLDC
Temperature Control Microprocessor, Thermostat for cooling and heating
Sound Absorbing Thermal Insulation Material Foamed polystrene Foamed polystrene Foamed polystrene
Air Filter - - -
Safety Device Fuse Fuse Fuse
Liquid Side mm(inch) Ø6.35(1/4) Ø6.35(1/4) Ø6.35(1/4)
Pipe Connections Gas Side mm(inch) Ø12.7(1/2) Ø12.7(1/2) Ø12.7(1/2)
Drain Pipe(Internal Dia.) mm(inch) 25.4(1) 25.4(1) 25.4(1)
Net Weight kg(lbs) 17.5 (38.6) 17.5 (38.6) 17.5 (38.6)
Noise Level (Sound Pressure, 1.5m, H/M/L) dB(A) 25 / 24 / 22 26 / 24 / 22 28 / 25 / 22
1, 220 - 240, 50 1, 220 - 240, 50 1, 220 - 240, 50
Power Supply Ø, V, Hz
1, 220, 60 1, 220, 60 1, 220, 60
Refrigerant Control EEV EEV EEV
Power cable mm2 CV2.5 x 3C CV2.5 x 3C CV2.5 x 3C
Transmission cable mm2 1.0~1.5 x 2C 1.0~1.5 x 2C 1.0~1.5 x 2C
Notes:-
Conversion Formula
1. Capacities are based on the following conditions:
Cooling • Indoor temp. 27°C[80.6°F]DB/ 19°C[66.2°F]WB kcal/h= kW x 860
• Outdoor temp. 35°C[95°F]DB/ 24°C[75.2°F]WB Btu/h = kW x 3412
• Interconnecting Piping Length 7.5m cfm = m3/min x 35.3
• Level Difference of Zero l/s = CMM x 1000/60
Heating • Indoor temp. 20°C[68°F]DB/ 15°C[59°F]WB
• Outdoor temp. 7°C[44.6°F]DB/ 6°C[42.8°F]WB
• Interconnecting Piping Length 7.5m
• Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. EEV : Electronic Expansion Valve
5. Sound pressure levels are measured at 20Pa External Static Pressure condition.
6. Anechoic chamber conversion value is measured at 1.5 m downward from unit centre.
The values depends on the ambient conditions and values are normally higher in actual operation.

4 _ Ceiling Concealed Duct(Low Static)


2. Specifications
Type Ceiling Concealed Duct (Low Static)
Model Unit ARNU12GL2G2 ARNU15GL2G2 ARNU18GL2G2
kW 3.6 4.5 5.6
Cooling Capacity kcal/h 3,100 3,900 4,800
Btu/h 12,300 15,400 19,100
kW 4.0 5.0 6.3
Heating Capacity kcal/h 3,400 4,300 5,400
Btu/h 13,600 17,100 21,500
Casing Galvanized Steel Plate Galvanized Steel Plate Galvanized Steel Plate
mm 900 x 190 x 700 900 x 190 x 700 900 x 190 x 700
Dimensions(WxHxD) Body
inch 35-7/16 × 7-15/32 × 27-9/16 35-7/16 × 7-15/32 × 27-9/16 35-7/16 × 7-15/32 × 27-9/16
Coil Rows x Columns x FPI 2 x 11 x 18 2 x 11 x 18 2 x 11 x 18
Face Area m2 0.17 0.17 0.17
Type Sirocco Fan Sirocco Fan Sirocco Fan
Motor Output x Number W 19 x 1, 5 x 1 19 x 1, 5 x 1 19 x 1, 5 x 1
Running Current A 0.76 0.76 0.76
Air Flow Rate(H / M / L) CMM 10.0 / 8.5 / 7.0 12.5 / 10.0 / 8.5 15.0 / 12.5 / 10.0
(High Mode-factory set) cfm 360 / 310 / 250 450 / 360 / 310 530 / 450 / 360

Indoor Units
Fan External Static Pressure mmAq(Pa) 2.54 (25) 2.54 (25) 2.54 (25)
Air Flow Rate(H / M / L) CMM 10.0 / 8.5 / 7.0 12.5 / 10.0 / 8.5 15.0 / 12.5 / 10.0
(Standard Mode) cfm 360 / 310 / 250 450 / 360 / 310 530 / 450 / 360
External Static Pressure mmAq(Pa) 0 (0) 0 (0) 0 (0)
Drive Direct Direct Direct
Motor type BLDC BLDC BLDC
Temperature Control Microprocessor, Thermostat for cooling and heating
Sound Absorbing Thermal Insulation Material Foamed polystrene Foamed polystrene Foamed polystrene
Air Filter - - -
Safety Device Fuse Fuse Fuse
Liquid Side mm(inch) Ø6.35(1/4) Ø6.35(1/4) Ø6.35(1/4)
Pipe Connections Gas Side mm(inch) Ø12.7(1/2) Ø12.7(1/2) Ø12.7(1/2)
Drain Pipe(Internal Dia.) mm(inch) 25.4(1) 25.4(1) 25.4(1)
Net Weight kg(lbs) 23 (50.7) 23 (50.7) 23 (50.7)
Noise Level (Sound Pressure, 1.5m, H/M/L) dB(A) 30 / 27 / 25 33 / 30 / 28 35 / 32 / 29
1, 220 - 240, 50 1, 220 - 240, 50 1, 220 - 240, 50
Power Supply Ø, V, Hz
1, 220, 60 1, 220, 60 1, 220, 60
Refrigerant Control EEV EEV EEV
Power cable mm2 CV2.5 x 3C CV2.5 x 3C CV2.5 x 3C
Transmission cable mm2 1.0~1.5 x 2C 1.0~1.5 x 2C 1.0~1.5 x 2C
Notes:-
Conversion Formula
1. Capacities are based on the following conditions:
Cooling • Indoor temp. 27°C[80.6°F]DB/ 19°C[66.2°F]WB kcal/h= kW x 860
• Outdoor temp. 35°C[95°F]DB/ 24°C[75.2°F]WB Btu/h = kW x 3412
• Interconnecting Piping Length 7.5m cfm = m3/min x 35.3
• Level Difference of Zero l/s = CMM x 1000/60
Heating • Indoor temp. 20°C[68°F]DB/ 15°C[59°F]WB
• Outdoor temp. 7°C[44.6°F]DB/ 6°C[42.8°F]WB
• Interconnecting Piping Length 7.5m
• Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. EEV : Electronic Expansion Valve
5. Sound pressure levels are measured at 20Pa External Static Pressure condition.
6. Anechoic chamber conversion value is measured at 1.5 m downward from unit centre.
The values depends on the ambient conditions and values are normally higher in actual operation.

Ceiling Concealed Duct(Low Static) _ 5


2. Specifications
Type Ceiling Concealed Duct (Low Static)
Model Unit ARNU21GL3G2 ARNU24GL3G2
kW 6.2 7.1
Cooling Capacity kcal/h 5,300 6,100
Btu/h 21,000 24,000
kW 7.0 8.0
Heating Capacity kcal/h 6,000 6,900
Btu/h 23,900 27,300
Casing Galvanized Steel Plate Galvanized Steel Plate
mm 1,100 × 190 × 700 1,100 × 190 × 700
Dimensions(WxHxD) Body
inch 43-5/16 × 7-15/32 × 27-9/16 43-5/16 × 7-15/32 × 27-9/16
Coil Rows x Columns x FPI 2 x 11 x 18 2 x 11 x 18
Face Area m2 0.21 0.21
Type Sirocco Fan Sirocco Fan
Motor Output x Number W 19 x 2 19 x 2
Running Current A 0.97 0.97
Air Flow Rate(H / M / L) CMM 17.5 / 14.0 / 12.0 20.0 / 16.0 / 12.0
(High Mode-factory set) cfm 620 / 500 / 430 710 / 570 / 430
Indoor Units

Fan External Static Pressure mmAq(Pa) 2.54 (25) 2.54 (25)


Air Flow Rate(H / M / L) CMM 17.5 / 14.0 / 12.0 20.0 / 16.0 / 12.0
(Standard Mode) cfm 620 / 500 / 430 710 / 570 / 430
External Static Pressure mmAq(Pa) 0 (0) 0 (0)
Drive Direct Direct
Motor type BLDC BLDC
Temperature Control Microprocessor, Thermostat for cooling and heating
Sound Absorbing Thermal Insulation Material Foamed polystrene Foamed polystrene
Air Filter - -
Safety Device Fuse Fuse
Liquid Side mm(inch) Ø9.52(3/8) Ø9.52(3/8)
Pipe Connections Gas Side mm(inch) Ø15.88(5/8) Ø15.88(5/8)
Drain Pipe(Internal Dia.) mm(inch) 25.4(1) 25.4(1)
Net Weight kg(lbs) 27 (59.5) 27 (59.5)
Noise Level (Sound Pressure, 1.5m, H/M/L) dB(A) 35 / 29 / 28 36 / 33 / 28
1, 220 - 240, 50 1, 220 - 240, 50
Power Supply Ø, V, Hz
1, 220, 60 1, 220, 60
Refrigerant Control EEV EEV
Power cable mm2 CV2.5 x 3C CV2.5 x 3C
Transmission cable mm2 1.0~1.5 x 2C 1.0~1.5 x 2C
Notes:-
Conversion Formula
1. Capacities are based on the following conditions:
Cooling • Indoor temp. 27°C[80.6°F]DB/ 19°C[66.2°F]WB kcal/h= kW x 860
• Outdoor temp. 35°C[95°F]DB/ 24°C[75.2°F]WB Btu/h = kW x 3412
• Interconnecting Piping Length 7.5m cfm = m3/min x 35.3
• Level Difference of Zero l/s = CMM x 1000/60
Heating • Indoor temp. 20°C[68°F]DB/ 15°C[59°F]WB
• Outdoor temp. 7°C[44.6°F]DB/ 6°C[42.8°F]WB
• Interconnecting Piping Length 7.5m
• Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. EEV : Electronic Expansion Valve
5. Sound pressure levels are measured at 20Pa External Static Pressure condition.
6. Anechoic chamber conversion value is measured at 1.5 m downward from unit centre.
The values depends on the ambient conditions and values are normally higher in actual operation.

6 _ Ceiling Concealed Duct(Low Static)


Ceiling Concealed Duct (Low Static)

ARNU07GB1G2 ARNU15GB1G2
ARNU09GB1G2 ARNU18GB2G2
ARNU12GB1G2 ARNU24GB2G2

D 5 13

(unit: mm)

161
A B C D
190
ARNU07GB1G2
65 60

14
ARNU09GB1G2
820 728 856 794
ARNU12GB1G2
1
ARNU15GB1G2

216
2 ARNU18GB2G2

277
ARNU24GB2G2 1100 1008 1131 1072

24

575
383
(unit : mm)
3. Dimensions & Gravity point

Number Name Descripition


3
Unit size(7k,9k,12k,18k):ø6.35

B1 : 186
B2 : 175
1 Liquid pipe connection Unit size(24k):ø9.52
Unit size(7k,9k,12k,18k):ø12.7
2 Gas pipe connection Unit size(24k):ø15.88
B1 : 448
B2 : 573 3 Drain pipe connection
C 4
4 Power supply connection

18
6
5 Air discharge
6 Air suction

190
154
Note

B1 : 73
B2 : 81
1. Unit should be installed in compliance with the installation manual
18 B in the product box.
A 2. Unit shall be grounded in accordance with the local regulations or
applicable national codes.

Gravity point

76, Seongsan-dong, Changwon City, Gyeongnam,


641-713, Korea CHASSIS CODE: B1/B2

Ceiling Concealed Duct(Low Static) _ 7


Indoor Units
Indoor Units

Ceiling Concealed Duct (Low Static)

ARNU05GL1G2 ARNU15GL2G2
ARNU07GL1G2 ARNU18GL2G2
ARNU09GL1G2 ARNU21GL3G2
ARNU12GL2G2 ARNU24GL3G2

5
20 D

(unit: mm)

135
A B C D

34
ARNU05GL1G2
190
100 ARNU07GL1G2 774 700 733 660
94 ARNU09GL1G2

8 _ Ceiling Concealed Duct(Low Static)


ARNU12GL2G2
2 ARNU15GL2G2 974 900 933 860
ARNU18GL2G2

292
67 119
1
ARNU21GL3G2
1,174 1,100 1,133 1,060
3. Dimensions & Gravity point

3 ARNU24GL3G2
(unit : mm)

700
628
Number Name Descripition
Unit size(5k,7k,9k,12k,18k) : 6.35

220
1 Liquid pipe connection Unit size(21k, 24k) : 9.52
4
Unit size(5k,7k,9k,12k,18k) : 12.7
2 Gas pipe connection Unit size(21k, 24k) : 15.88
L1 : 366 3 Drain pipe connection
L2 : 561
L3 : 755 C 4 Power supply connection
6
5 Air discharge

20
6 Air suction
Note

190
155
L1 : 75
L2 : 78
L3 : 81

1. Unit should be installed in compliance with the installation manual


B in the product box.
A
Gravity point 2. Unit shall be grounded in accordance with the local regulations or
applicable national codes.

76, Seongsan-dong, Changwon City, Gyeongnam,


641-713, Korea CHASSIS CODE: L1/L2/L3
4. Piping Diagrams

:Cooling
Heat Exchanger EEV :Heating
Filter

Th3 Th2
Sirocco Fan Filter

Th1 lndoor unit

Indoor Units
Refrigerant pipe connection port diameter

[Unit: mm(inch)]

MODEL GAS LIQUID


ARNU05GL1G2 Ø12.7(1/2) Ø6.35(1/4)
ARNU07GB1G2
Ø12.7(1/2) Ø6.35(1/4)
ARNU07GL1G2
ARNU09GB1G2
Ø12.7(1/2) Ø6.35(1/4)
ARNU09GL1G2
ARNU12GB1G2
Ø12.7(1/2) Ø6.35(1/4)
ARNU12GL2G2
ARNU15GB1G2
Ø12.7(1/2) Ø6.35(1/4)
ARNU15GL2G2
ARNU18GB2G2
Ø12.7(1/2) Ø6.35(1/4)
ARNU18GL2G2
ARNU21GL3G2 Ø15.88(5/8) Ø9.52(3/8)
ARNU24GB2G2
Ø15.88(5/8) Ø9.52(3/8)
ARNU24GL3G2

LOC. Description
Th1 Room thermistor
Th2 Pipe in thermistor
Th3 Pipe out thermistor

Ceiling Concealed Duct(Low Static) _ 9


5. Wiring Diagrams
B1/B2 Chassis
Indoor Units

CONNECTOR NUMBER SPEC. DESCRIPTION


CN-MOTOR1 Fan motor output Motor output of BLDC
CN-MOTOR2 Fan motor output Motor output of BLDC
CN-PIPE/OUT Discharge pipe sensor Pipe out thermistor
CN-PIPE/IN Suction pipe sensor Pipe in thermistor
CN-ROOM Room sensor Room thermistor
CN-REMO Remote controller Remote control line
CN-FLOAT Float switch input Float switch sensing
CN-EEV EEV output EEV control output
CN-D/PUMP Drain pump output AC output for drain pump
CN-OPTION Option PWB. Communication between main and option
CN-COM Communication Communication between indoor and outdoor
CN-POWER AC power supply AC power line input for indoor controller
CN-ZONE Zone Controller Zone control line
CN-DISPLAY RF Remote controller RF remote control line
CN-CC Dry contact Dry contact line

Dip Switch Setting Off On Remarks


SW3 GROUP Master Slave Group Control setting using Wired Remote Controller
Old Dry Contact Mode Setting
1. Variable : Auto/Manual Mode can be chosen by Wide wired
SW4 DRY CONTACT Variable Auto remote controller or Wireless remote controller
(When shipped from Factory ’ Manual Mode)
2. Auto : For Dry Contact, it is always Auto mode.
1. Duct model
-. OFF : Default(not operate continuosly )
-. ON : Fan operate continuosly
SW5 EXTRA 1 Off On 2. Cassette Model : No Function
3. Ceiling Suspended Model
-. OFF : Ceiling(default)
-. ON : Floor

CAUTION
For Multi V Model, Dip Switch 1,2,6,7,8 must be set OFF
That dip switch is used for the other model.

10 _ Ceiling Concealed Duct(Low Static)


5. Wiring Diagrams
L1 Chassis

Indoor Units
CONNECTOR NUMBER SPEC. DESCRIPTION
CN-MOTOR1 Fan motor output Motor output of BLDC
CN-MOTOR2 Fan motor output Motor output of BLDC
CN-PIPE/OUT Discharge pipe sensor Pipe out thermistor
CN-PIPE/IN Suction pipe sensor Pipe in thermistor
CN-ROOM Room sensor Room thermistor
CN-REMO Remote controller Remote control line
CN-FLOAT Float switch input Float switch sensing
CN-EEV EEV output EEV control output
CN-D/PUMP Drain pump output AC output for drain pump
CN-OPTION Option PWB. Communication between main and option
CN-COM Communication Communication between indoor and outdoor
CN-POWER AC power supply AC power line input for indoor controller
CN-ZONE Zone Controller Zone control line
CN-DISPLAY RF Remote controller RF remote control line
CN-CC Dry contact Dry contact line

Dip Switch Setting Off On Remarks


SW3 GROUP Master Slave Group Control setting using Wired Remote Controller
Old Dry Contact Mode Setting
1. Variable : Auto/Manual Mode can be chosen by Wide wired
SW4 DRY CONTACT Variable Auto remote controller or Wireless remote controller
(When shipped from Factory ’ Manual Mode)
2. Auto : For Dry Contact, it is always Auto mode.
1. Duct model
-. OFF : Default(not operate continuosly )
-. ON : Fan operate continuosly
SW5 EXTRA 1 Off On 2. Cassette Model : No Function
3. Ceiling Suspended Model
-. OFF : Ceiling(default)
-. ON : Floor

CAUTION
For Multi V Model, Dip Switch 1,2,6,7,8 must be set OFF
That dip switch is used for the other model.

Ceiling Concealed Duct(Low Static) _ 11


5. Wiring Diagrams
L2/L3 Chassis
Indoor Units

CONNECTOR NUMBER SPEC. DESCRIPTION


CN-MOTOR1 Fan motor output Motor output of BLDC
CN-MOTOR2 Fan motor output Motor output of BLDC
CN-PIPE/OUT Discharge pipe sensor Pipe out thermistor
CN-PIPE/IN Suction pipe sensor Pipe in thermistor
CN-ROOM Room sensor Room thermistor
CN-REMO Remote controller Remote control line
CN-FLOAT Float switch input Float switch sensing
CN-EEV EEV output EEV control output
CN-D/PUMP Drain pump output AC output for drain pump
CN-OPTION Option PWB. Communication between main and option
CN-COM Communication Communication between indoor and outdoor
CN-POWER AC power supply AC power line input for indoor controller
CN-ZONE Zone Controller Zone control line
CN-DISPLAY RF Remote controller RF remote control line
CN-CC Dry contact Dry contact line

Dip Switch Setting Off On Remarks


SW3 GROUP Master Slave Group Control setting using Wired Remote Controller
Old Dry Contact Mode Setting
1. Variable : Auto/Manual Mode can be chosen by Wide wired
SW4 DRY CONTACT Variable Auto remote controller or Wireless remote controller
(When shipped from Factory ’ Manual Mode)
2. Auto : For Dry Contact, it is always Auto mode.
1. Duct model
-. OFF : Default(not operate continuosly )
-. ON : Fan operate continuosly
SW5 EXTRA 1 Off On 2. Cassette Model : No Function
3. Ceiling Suspended Model
-. OFF : Ceiling(default)
-. ON : Floor

CAUTION
For Multi V Model, Dip Switch 1,2,6,7,8 must be set OFF
That dip switch is used for the other model.

12 _ Ceiling Concealed Duct(Low Static)


6. Capacity Tables
6.1 Cooling Capacity
Cooling capacity
6.1.1 B1/B2 Chassis

Indoor air temp. (DB/WB, °C)


Capacity Outdoor 20 23 26 27 28 30 32
Index air temp. 14 16 18 19 20 22 24
(DB, °C) TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.6 1.7 2.9 1.7
12 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.6 1.7 2.9 1.7
14 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.6 1.7 2.8 1.7
16 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.6 1.7 2.8 1.6
18 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.6 1.7 2.7 1.6
20 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.6 1.7 2.7 1.6
21 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.6 1.7 2.7 1.6
23 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.6 1.7 2.6 1.6
2.2 25 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.6 1.7 2.6 1.5

Indoor Units
27 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.5 1.7 2.6 1.5
29 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.5 1.6 2.5 1.5
31 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.5 1.6 2.5 1.5
33 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.4 1.6 2.5 1.5
35 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.4 1.6 2.4 1.4
37 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.6 2.3 1.5 2.4 1.4
39 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.2 1.6 2.3 1.5 2.3 1.4
10 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.7 2.2
12 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.6 2.1
14 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.6 2.1
16 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.5 2.1
18 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.5 2.1
20 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.4 2.0
21 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.4 2.0
23 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.4 2.0
2.8 25 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.3 2.2 3.3 2.0
27 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.2 2.1 3.3 1.9
29 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.2 2.1 3.2 1.9
31 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.1 2.1 3.2 1.9
33 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.1 2.0 3.1 1.9
35 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.0 2.0 3.1 1.8
37 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 2.9 2.1 3.0 1.9 3.0 1.8
39 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 2.9 2.0 2.9 1.9 3.0 1.8
10 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.7 2.8
12 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.7 2.8
14 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.6 2.7
16 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.6 2.7
18 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.5 2.7
20 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.4 2.6
21 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.4 2.6
23 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.3 2.6
3.6 25 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.2 2.8 4.3 2.5
27 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.1 2.7 4.2 2.5
29 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.1 2.7 4.2 2.5
31 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.0 2.6 4.1 2.4
33 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.0 2.6 4.0 2.4
35 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 3.9 2.6 4.0 2.3
37 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.7 2.6 3.8 2.5 3.9 2.3
39 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.7 2.6 3.7 2.5 3.8 2.3

Ceiling Concealed Duct(Low Static) _ 13


6. Capacity Tables

Cooling capacity

Indoor air temp. (DB/WB, °C)


Capacity Outdoor 20 23 26 27 28 30 32
Index air temp. 14 16 18 19 20 22 24
(DB, °C) TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.6 5.9 3.5
12 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.6 5.8 3.5
14 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.6 5.8 3.4
16 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.6 5.7 3.4
18 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.6 5.6 3.4
20 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.6 5.5 3.3
21 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.6 5.5 3.3
23 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.6 5.4 3.2
4.5 25 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.3 3.5 5.3 3.2
27 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.2 3.4 5.3 3.2
29 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.1 3.4 5.2 3.1
Indoor Units

31 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.1 3.3 5.1 3.0
33 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 4.9 3.3 5.0 3.0
35 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 4.9 3.2 4.9 3.0
37 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.7 3.3 4.8 3.2 4.9 2.9
39 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.6 3.2 4.7 3.1 4.8 2.8
10 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 6.0 4.1 6.7 4.3 7.4 4.2
12 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 6.0 4.1 6.7 4.3 7.3 4.2
14 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 6.0 4.1 6.7 4.3 7.2 4.1
16 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 6.0 4.1 6.7 4.3 7.1 4.1
18 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 6.0 4.1 6.7 4.3 7.0 4.0
20 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 6.0 4.1 6.7 4.3 6.9 4.0
21 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 6.0 4.1 6.7 4.3 6.8 3.9
23 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 6.0 4.1 6.7 4.3 6.7 3.9
5.6 25 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 6.0 4.1 6.6 4.2 6.6 3.8
27 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 6.0 4.1 6.4 4.1 6.6 3.8
29 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 6.0 4.1 6.4 4.1 6.5 3.7
31 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 6.0 4.1 6.3 4.0 6.4 3.7
33 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 6.0 4.1 6.2 3.9 6.3 3.6
35 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 6.0 4.1 6.0 3.9 6.2 3.5
37 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 5.8 4.0 5.9 3.8 6.1 3.5
39 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 5.7 3.9 5.8 3.7 6.0 3.4
10 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.5 5.4 9.3 5.4
12 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.5 5.4 9.2 5.3
14 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.5 5.4 9.1 5.2
16 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.5 5.4 9.0 5.2
18 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.5 5.4 8.8 5.1
20 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.5 5.4 8.7 5.0
21 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.5 5.4 8.7 5.0
23 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.5 5.4 8.5 4.9
7.1 25 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.4 5.4 8.4 4.8
27 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.2 5.2 8.3 4.8
29 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.1 5.2 8.2 4.7
31 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.0 5.1 8.1 4.6
33 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 7.8 5.0 7.9 4.6
35 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 7.7 4.9 7.8 4.5
37 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.4 5.1 7.5 4.8 7.7 4.4
39 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.2 5.0 7.4 4.7 7.6 4.4

14 _ Ceiling Concealed Duct(Low Static)


6. Capacity Tables
Cooling capacity
6.1.2 L1/L2/L3 Chassis
Indoor air temp. (DB/WB, °C)
Capacity Outdoor 20 23 26 27 28 30 32
Index air temp. 14 16 18 19 20 22 24
(DB, °C) TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10 1.1 1.1 1.4 1.3 1.6 1.4 1.7 1.4 1.8 1.5 2.0 1.5 2.2 1.5
12 1.1 1.1 1.4 1.3 1.6 1.4 1.7 1.4 1.8 1.5 2.0 1.5 2.2 1.5
14 1.1 1.1 1.4 1.3 1.6 1.4 1.7 1.4 1.8 1.5 2.0 1.5 2.2 1.5
16 1.1 1.1 1.4 1.3 1.6 1.4 1.7 1.4 1.8 1.5 2.0 1.5 2.2 1.4
18 1.1 1.1 1.4 1.3 1.6 1.4 1.7 1.4 1.8 1.5 2.0 1.5 2.1 1.4
20 1.1 1.1 1.4 1.3 1.6 1.4 1.7 1.4 1.8 1.5 2.0 1.5 2.1 1.4
21 1.1 1.1 1.4 1.3 1.6 1.4 1.7 1.4 1.8 1.5 2.0 1.5 2.1 1.4
23 1.1 1.1 1.4 1.3 1.6 1.4 1.7 1.4 1.8 1.5 2.0 1.5 2.0 1.4
1.6 25 1.1 1.1 1.4 1.3 1.6 1.4 1.7 1.4 1.8 1.5 2.0 1.5 2.0 1.4
27 1.1 1.1 1.4 1.3 1.6 1.4 1.7 1.4 1.8 1.5 2.0 1.5 2.0 1.4
29 1.1 1.1 1.4 1.3 1.6 1.4 1.7 1.4 1.8 1.5 1.9 1.4 2.0 1.3

Indoor Units
31 1.1 1.1 1.4 1.3 1.6 1.4 1.7 1.4 1.8 1.5 1.9 1.4 1.9 1.3
33 1.1 1.1 1.4 1.3 1.6 1.4 1.7 1.4 1.8 1.5 1.9 1.4 1.9 1.3
35 1.1 1.1 1.4 1.3 1.6 1.4 1.7 1.4 1.8 1.5 1.8 1.4 1.9 1.3
37 1.1 1.1 1.4 1.3 1.6 1.4 1.7 1.4 1.8 1.4 1.8 1.4 1.8 1.2
39 1.1 1.1 1.4 1.3 1.6 1.4 1.7 1.4 1.7 1.4 1.8 1.3 1.8 1.2
10 1.5 1.4 1.8 1.5 2.0 1.6 2.2 1.7 2.4 1.7 2.6 1.8 2.9 1.8
12 1.5 1.4 1.8 1.5 2.0 1.6 2.2 1.7 2.4 1.7 2.6 1.8 2.9 1.8
14 1.5 1.4 1.8 1.5 2.0 1.6 2.2 1.7 2.4 1.7 2.6 1.8 2.8 1.7
16 1.5 1.4 1.8 1.5 2.0 1.6 2.2 1.7 2.4 1.7 2.6 1.8 2.8 1.7
18 1.5 1.4 1.8 1.5 2.0 1.6 2.2 1.7 2.4 1.7 2.6 1.8 2.7 1.7
20 1.5 1.4 1.8 1.5 2.0 1.6 2.2 1.7 2.4 1.7 2.6 1.8 2.7 1.7
21 1.5 1.4 1.8 1.5 2.0 1.6 2.2 1.7 2.4 1.7 2.6 1.8 2.7 1.7
23 1.5 1.4 1.8 1.5 2.0 1.6 2.2 1.7 2.4 1.7 2.6 1.8 2.6 1.6
2.2 25 1.5 1.4 1.8 1.5 2.0 1.6 2.2 1.7 2.4 1.7 2.6 1.8 2.6 1.6
27 1.5 1.4 1.8 1.5 2.0 1.6 2.2 1.7 2.4 1.7 2.5 1.7 2.6 1.6
29 1.5 1.4 1.8 1.5 2.0 1.6 2.2 1.7 2.4 1.7 2.5 1.7 2.5 1.6
31 1.5 1.4 1.8 1.5 2.0 1.6 2.2 1.7 2.4 1.7 2.5 1.7 2.5 1.5
33 1.5 1.4 1.8 1.5 2.0 1.6 2.2 1.7 2.4 1.7 2.4 1.7 2.4 1.5
35 1.5 1.4 1.8 1.5 2.0 1.6 2.2 1.7 2.4 1.7 2.4 1.6 2.4 1.5
37 1.5 1.4 1.8 1.5 2.0 1.6 2.2 1.7 2.3 1.7 2.3 1.6 2.4 1.5
39 1.5 1.4 1.8 1.5 2.0 1.6 2.2 1.7 2.2 1.6 2.3 1.6 2.4 1.4
10 1.9 1.8 2.2 1.9 2.6 2.1 2.8 2.1 3.0 2.2 3.4 2.3 3.7 2.3
12 1.9 1.8 2.2 1.9 2.6 2.1 2.8 2.1 3.0 2.2 3.4 2.3 3.6 2.3
14 1.9 1.8 2.2 1.9 2.6 2.1 2.8 2.1 3.0 2.2 3.4 2.3 3.6 2.2
16 1.9 1.8 2.2 1.9 2.6 2.1 2.8 2.1 3.0 2.2 3.4 2.3 3.5 2.2
18 1.9 1.8 2.2 1.9 2.6 2.1 2.8 2.1 3.0 2.2 3.4 2.3 3.5 2.2
20 1.9 1.8 2.2 1.9 2.6 2.1 2.8 2.1 3.0 2.2 3.4 2.3 3.4 2.1
21 1.9 1.8 2.2 1.9 2.6 2.1 2.8 2.1 3.0 2.2 3.4 2.3 3.4 2.1
23 1.9 1.8 2.2 1.9 2.6 2.1 2.8 2.1 3.0 2.2 3.4 2.3 3.4 2.1
2.8 25 1.9 1.8 2.2 1.9 2.6 2.1 2.8 2.1 3.0 2.2 3.3 2.3 3.3 2.0
27 1.9 1.8 2.2 1.9 2.6 2.1 2.8 2.1 3.0 2.2 3.2 2.2 3.3 2.0
29 1.9 1.8 2.2 1.9 2.6 2.1 2.8 2.1 3.0 2.2 3.2 2.2 3.2 2.0
31 1.9 1.8 2.2 1.9 2.6 2.1 2.8 2.1 3.0 2.2 3.2 2.1 3.2 2.0
33 1.9 1.8 2.2 1.9 2.6 2.1 2.8 2.1 3.0 2.2 3.1 2.1 3.1 1.9
35 1.9 1.8 2.2 1.9 2.6 2.1 2.8 2.1 3.0 2.2 3.0 2.1 3.1 1.9
37 1.9 1.8 2.2 1.9 2.6 2.1 2.8 2.1 2.9 2.1 3.0 2.0 3.0 1.9
39 1.9 1.8 2.2 1.9 2.6 2.1 2.8 2.1 2.8 2.1 2.9 2.0 3.0 1.8

Ceiling Concealed Duct(Low Static) _ 15


6. Capacity Tables
Cooling capacity

Indoor air temp. (DB/WB, °C)


Capacity Outdoor 20 23 26 27 28 30 32
Index air temp. 14 16 18 19 20 22 24
(DB, °C) TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10 2.4 2.2 2.9 2.4 3.3 2.6 3.6 2.6 3.9 2.7 4.3 2.8 4.7 2.8
12 2.4 2.2 2.9 2.4 3.3 2.6 3.6 2.6 3.9 2.7 4.3 2.8 4.7 2.8
14 2.4 2.2 2.9 2.4 3.3 2.6 3.6 2.6 3.9 2.7 4.3 2.8 4.6 2.7
16 2.4 2.2 2.9 2.4 3.3 2.6 3.6 2.6 3.9 2.7 4.3 2.8 4.6 2.7
18 2.4 2.2 2.9 2.4 3.3 2.6 3.6 2.6 3.9 2.7 4.3 2.8 4.5 2.7
20 2.4 2.2 2.9 2.4 3.3 2.6 3.6 2.6 3.9 2.7 4.3 2.8 4.4 2.6
21 2.4 2.2 2.9 2.4 3.3 2.6 3.6 2.6 3.9 2.7 4.3 2.8 4.4 2.6
23 2.4 2.2 2.9 2.4 3.3 2.6 3.6 2.6 3.9 2.7 4.3 2.8 4.3 2.6
3.6 25 2.4 2.2 2.9 2.4 3.3 2.6 3.6 2.6 3.9 2.7 4.3 2.8 4.3 2.5
27 2.4 2.2 2.9 2.4 3.3 2.6 3.6 2.6 3.9 2.7 4.2 2.7 4.2 2.5
29 2.4 2.2 2.9 2.4 3.3 2.6 3.6 2.6 3.9 2.7 4.1 2.7 4.2 2.5
Indoor Units

31 2.4 2.2 2.9 2.4 3.3 2.6 3.6 2.6 3.9 2.7 4.1 2.6 4.1 2.4
33 2.4 2.2 2.9 2.4 3.3 2.6 3.6 2.6 3.9 2.7 4.0 2.6 4.0 2.4
35 2.4 2.2 2.9 2.4 3.3 2.6 3.6 2.6 3.9 2.7 3.9 2.6 4.0 2.4
37 2.4 2.2 2.9 2.4 3.3 2.6 3.6 2.6 3.8 2.6 3.8 2.5 3.9 2.3
39 2.4 2.2 2.9 2.4 3.3 2.6 3.6 2.6 3.7 2.6 3.8 2.5 3.9 2.3
10 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.5 5.9 3.5
12 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.5 5.8 3.5
14 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.5 5.8 3.4
16 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.5 5.7 3.3
18 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.5 5.6 3.3
20 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.5 5.5 3.3
21 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.5 5.5 3.3
23 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.5 5.4 3.2
4.5 25 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.3 3.5 5.3 3.2
27 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.2 3.4 5.3 3.2
29 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.1 3.3 5.2 3.1
31 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.1 3.3 5.1 3.0
33 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 4.9 3.3 5.0 3.0
35 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 4.9 3.2 4.9 3.0
37 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.7 3.3 4.8 3.2 4.9 2.9
39 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.6 3.2 4.7 3.1 4.8 2.8
10 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 6.0 4.2 6.7 4.4 7.3 4.3
12 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 6.0 4.2 6.7 4.4 7.3 4.3
14 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 6.0 4.2 6.7 4.4 7.2 4.2
16 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 6.0 4.2 6.7 4.4 7.1 4.2
18 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 6.0 4.2 6.7 4.4 6.9 4.2
20 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 6.0 4.2 6.7 4.4 6.9 4.1
21 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 6.0 4.2 6.7 4.4 6.9 4.1
23 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 6.0 4.2 6.7 4.4 6.7 4.0
5.6 25 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 6.0 4.2 6.6 4.3 6.6 3.9
27 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 6.0 4.2 6.5 4.2 6.5 3.9
29 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 6.0 4.2 6.4 4.2 6.5 3.8
31 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 6.0 4.2 6.3 4.1 6.4 3.8
33 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 6.0 4.2 6.2 4.1 6.2 3.7
35 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 6.0 4.2 6.1 4.0 6.2 3.7
37 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 5.8 4.1 5.9 3.9 6.1 3.6
39 3.8 3.4 4.5 3.7 5.2 4.0 5.6 4.1 5.7 4.0 5.8 3.8 6.0 3.5

16 _ Ceiling Concealed Duct(Low Static)


6. Capacity Tables

Cooling capacity

Indoor air temp. (DB/WB, °C)


Capacity Outdoor 20 23 26 27 28 30 32
Index air temp. 14 16 18 19 20 22 24
(DB, °C) TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10 4.2 3.9 5.0 4.3 5.8 4.6 6.2 4.7 6.6 4.9 7.4 5.1 8.1 5.0
12 4.2 3.9 5.0 4.3 5.8 4.6 6.2 4.7 6.6 4.9 7.4 5.1 8.0 5.0
14 4.2 3.9 5.0 4.3 5.8 4.6 6.2 4.7 6.6 4.9 7.4 5.1 7.9 4.9
16 4.2 3.9 5.0 4.3 5.8 4.6 6.2 4.7 6.6 4.9 7.4 5.1 7.9 4.8
18 4.2 3.9 5.0 4.3 5.8 4.6 6.2 4.7 6.6 4.9 7.4 5.1 7.7 4.8
20 4.2 3.9 5.0 4.3 5.8 4.6 6.2 4.7 6.6 4.9 7.4 5.1 7.6 4.7
21 4.2 3.9 5.0 4.3 5.8 4.6 6.2 4.7 6.6 4.9 7.4 5.1 7.6 4.7
23 4.2 3.9 5.0 4.3 5.8 4.6 6.2 4.7 6.6 4.9 7.4 5.1 7.4 4.6
6.2 25 4.2 3.9 5.0 4.3 5.8 4.6 6.2 4.7 6.6 4.9 7.3 5.0 7.3 4.5
27 4.2 3.9 5.0 4.3 5.8 4.6 6.2 4.7 6.6 4.9 7.2 4.9 7.2 4.5

Indoor Units
29 4.2 3.9 5.0 4.3 5.8 4.6 6.2 4.7 6.6 4.9 7.1 4.8 7.2 4.4
31 4.2 3.9 5.0 4.3 5.8 4.6 6.2 4.7 6.6 4.9 7.0 4.7 7.1 4.3
33 4.2 3.9 5.0 4.3 5.8 4.6 6.2 4.7 6.6 4.9 6.8 4.7 6.9 4.3
35 4.2 3.9 5.0 4.3 5.8 4.6 6.2 4.7 6.6 4.9 6.7 4.6 6.8 4.3
37 4.2 3.9 5.0 4.3 5.8 4.6 6.2 4.7 6.5 4.7 6.5 4.5 6.7 4.2
39 4.2 3.9 5.0 4.3 5.8 4.6 6.2 4.7 6.3 4.6 6.5 4.4 6.6 4.1
10 4.8 4.4 5.7 4.9 6.6 5.3 7.1 5.4 7.6 5.6 8.5 5.8 9.3 5.7
12 4.8 4.4 5.7 4.9 6.6 5.3 7.1 5.4 7.6 5.6 8.5 5.8 9.2 5.7
14 4.8 4.4 5.7 4.9 6.6 5.3 7.1 5.4 7.6 5.6 8.5 5.8 9.1 5.6
16 4.8 4.4 5.7 4.9 6.6 5.3 7.1 5.4 7.6 5.6 8.5 5.8 9.0 5.5
18 4.8 4.4 5.7 4.9 6.6 5.3 7.1 5.4 7.6 5.6 8.5 5.8 8.8 5.5
20 4.8 4.4 5.7 4.9 6.6 5.3 7.1 5.4 7.6 5.6 8.5 5.8 8.7 5.4
21 4.8 4.4 5.7 4.9 6.6 5.3 7.1 5.4 7.6 5.6 8.5 5.8 8.7 5.4
23 4.8 4.4 5.7 4.9 6.6 5.3 7.1 5.4 7.6 5.6 8.5 5.8 8.5 5.3
7.1 25 4.8 4.4 5.7 4.9 6.6 5.3 7.1 5.4 7.6 5.6 8.4 5.7 8.4 5.2
27 4.8 4.4 5.7 4.9 6.6 5.3 7.1 5.4 7.6 5.6 8.2 5.6 8.3 5.2
29 4.8 4.4 5.7 4.9 6.6 5.3 7.1 5.4 7.6 5.6 8.1 5.5 8.2 5.1
31 4.8 4.4 5.7 4.9 6.6 5.3 7.1 5.4 7.6 5.6 8.0 5.4 8.1 5.0
33 4.8 4.4 5.7 4.9 6.6 5.3 7.1 5.4 7.6 5.6 7.8 5.4 7.9 4.9
35 4.8 4.4 5.7 4.9 6.6 5.3 7.1 5.4 7.6 5.6 7.7 5.3 7.8 4.9
37 4.8 4.4 5.7 4.9 6.6 5.3 7.1 5.4 7.4 5.4 7.5 5.2 7.7 4.8
39 4.8 4.4 5.7 4.9 6.6 5.3 7.1 5.4 7.2 5.3 7.4 5.1 7.6 4.7

Notes:
TC: Total Capacity(kW), SHC: Sensible Heat Capacity(kW) 2. Refer to Capacity Correction Factor in the outdoor unit PDB for
1. Capacity tables show the representative value of conditions the actual performance data of each indoor unit and outdoor unit
which may occur. combination.

Ceiling Concealed Duct(Low Static) _ 17


6. Capacity Tables
6.2 Heating Capacity Heating capacity

Outdoor air Indoor air temp. (DB, °C)


Capacity temp. 16 18 20 21 22 24
Index TC TC TC TC TC TC
DB(°C) WB(°C)
kW kW kW kW kW kW
-24.8 -25.0 1.1 1.1 1.1 1.1 1.1 1.1
-21.8 -22.0 1.3 1.3 1.3 1.3 1.3 1.3
-19.8 -20.0 1.4 1.4 1.4 1.4 1.4 1.4
-18.8 -19.0 1.4 1.4 1.4 1.4 1.4 1.4
-16.7 -17.0 1.5 1.5 1.5 1.5 1.5 1.5
-14.7 -15.0 1.6 1.6 1.6 1.6 1.6 1.6
-12.6 -13.0 1.6 1.6 1.6 1.6 1.6 1.6
-10.5 -11.0 1.7 1.7 1.7 1.7 1.7 1.7
-9.5 -10.0 1.8 1.8 1.7 1.7 1.7 1.7
-8.5 -9.1 1.8 1.8 1.8 1.8 1.8 1.7
-7.0 -7.6 1.8 1.8 1.8 1.8 1.8 1.7
1.6 -5.0 -5.6 1.9 1.9 1.9 1.8 1.8 1.7
-3.0 -3.7 2.0 1.9 1.9 1.8 1.8 1.7
0.0 -0.7 2.0 2.0 1.9 1.8 1.8 1.7
3.0 2.2 2.1 2.0 1.9 1.8 1.8 1.7
Indoor Units

5.0 4.1 2.1 2.0 1.9 1.8 1.8 1.7


7.0 6.0 2.1 2.0 1.9 1.8 1.8 1.7
9.0 7.9 2.1 2.0 1.9 1.8 1.8 1.7
11.0 9.8 2.1 2.0 1.9 1.8 1.8 1.7
13.0 11.8 2.1 2.0 1.9 1.8 1.8 1.7
15.0 13.7 2.1 2.0 1.9 1.8 1.8 1.7
-24.8 -25.0 1.4 1.4 1.4 1.4 1.4 1.4
-21.8 -22.0 1.7 1.7 1.7 1.7 1.7 1.7
-19.8 -20.0 1.8 1.8 1.8 1.8 1.8 1.8
-18.8 -19.0 1.9 1.9 1.9 1.9 1.9 1.9
-16.7 -17.0 2.0 2.0 2.0 2.0 2.0 2.0
-14.7 -15.0 2.1 2.1 2.1 2.1 2.1 2.0
-12.6 -13.0 2.2 2.2 2.2 2.2 2.1 2.1
-10.5 -11.0 2.3 2.3 2.2 2.2 2.2 2.2
-9.5 -10.0 2.3 2.3 2.3 2.3 2.3 2.2
-8.5 -9.1 2.3 2.3 2.3 2.3 2.3 2.2
2.2 -7.0 -7.6 2.4 2.4 2.4 2.4 2.3 2.2
-5.0 -5.6 2.5 2.5 2.5 2.4 2.3 2.2
-3.0 -3.7 2.6 2.6 2.5 2.4 2.3 2.2
0.0 -0.7 2.7 2.6 2.5 2.4 2.3 2.2
3.0 2.2 2.7 2.7 2.5 2.4 2.3 2.2
5.0 4.1 2.8 2.7 2.5 2.4 2.3 2.2
7.0 6.0 2.8 2.7 2.5 2.4 2.3 2.2
9.0 7.9 2.8 2.7 2.5 2.4 2.3 2.2
11.0 9.8 2.8 2.7 2.5 2.4 2.3 2.2
13.0 11.8 2.8 2.7 2.5 2.4 2.3 2.2
15.0 13.7 2.8 2.7 2.5 2.4 2.3 2.2
-24.8 -25.0 1.9 1.9 1.8 1.8 1.8 1.8
-21.8 -22.0 2.2 2.2 2.2 2.2 2.2 2.2
-19.8 -20.0 2.4 2.4 2.3 2.3 2.3 2.3
-18.8 -19.0 2.4 2.4 2.4 2.4 2.4 2.4
-16.7 -17.0 2.5 2.5 2.5 2.5 2.5 2.5
-14.7 -15.0 2.7 2.7 2.6 2.6 2.6 2.6
-12.6 -13.0 2.8 2.8 2.8 2.8 2.7 2.7
-10.5 -11.0 2.9 2.9 2.9 2.9 2.9 2.8
-9.5 -10.0 3.0 3.0 2.9 2.9 2.9 2.8
-8.5 -9.1 3.0 3.0 3.0 3.0 3.0 2.8
-7.0 -7.6 3.1 3.1 3.1 3.1 3.0 2.8
2.8 -5.0 -5.6 3.2 3.2 3.2 3.1 3.0 2.8
-3.0 -3.7 3.4 3.3 3.2 3.1 3.0 2.8
0.0 -0.7 3.4 3.3 3.2 3.1 3.0 2.8
3.0 2.2 3.5 3.4 3.2 3.1 3.0 2.8
5.0 4.1 3.6 3.4 3.2 3.1 3.0 2.8
7.0 6.0 3.6 3.4 3.2 3.1 3.0 2.8
9.0 7.9 3.6 3.4 3.2 3.1 3.0 2.8
11.0 9.8 3.6 3.4 3.2 3.1 3.0 2.8
13.0 11.8 3.6 3.4 3.2 3.1 3.0 2.8
15.0 13.7 3.6 3.4 3.2 3.1 3.0 2.8

18 _ Ceiling Concealed Duct(Low Static)


6. Capacity Tables
Heating capacity

Outdoor air Indoor air temp. (DB, °C)


Capacity temp. 16 18 20 21 22 24
Index TC TC TC TC TC TC
DB(°C) WB(°C)
kW kW kW kW kW kW
-24.8 -25.0 2.3 2.3 2.3 2.3 2.3 2.3
-21.8 -22.0 2.8 2.8 2.8 2.8 2.8 2.8
-19.8 -20.0 2.9 2.9 2.9 2.9 2.9 2.9
-18.8 -19.0 3.0 3.0 3.0 3.0 3.0 3.0
-16.7 -17.0 3.1 3.1 3.1 3.1 3.1 3.1
-14.7 -15.0 3.3 3.3 3.3 3.3 3.3 3.3
-12.6 -13.0 3.5 3.4 3.4 3.4 3.4 3.4
-10.5 -11.0 3.6 3.6 3.6 3.6 3.6 3.5
-9.5 -10.0 3.7 3.7 3.7 3.7 3.7 3.5
-8.5 -9.1 3.8 3.8 3.7 3.7 3.7 3.5
3.6 -7.0 -7.6 3.9 3.9 3.9 3.8 3.7 3.5
-5.0 -5.6 4.0 4.0 4.0 3.9 3.7 3.5
-3.0 -3.7 4.2 4.1 4.0 3.9 3.7 3.5
0.0 -0.7 4.3 4.1 4.0 3.9 3.7 3.5
3.0 2.2 4.4 4.3 4.0 3.9 3.7 3.5

Indoor Units
5.0 4.1 4.5 4.3 4.0 3.9 3.7 3.5
7.0 6.0 4.5 4.3 4.0 3.9 3.7 3.5
9.0 7.9 4.5 4.3 4.0 3.9 3.7 3.5
11.0 9.8 4.5 4.3 4.0 3.9 3.7 3.5
13.0 11.8 4.5 4.3 4.0 3.9 3.7 3.5
15.0 13.7 4.5 4.3 4.0 3.9 3.7 3.5
-24.8 -25.0 2.9 2.9 2.9 2.9 2.9 2.9
-21.8 -22.0 3.5 3.5 3.5 3.5 3.5 3.5
-19.8 -20.0 3.7 3.7 3.7 3.7 3.7 3.6
-18.8 -19.0 3.8 3.7 3.7 3.7 3.7 3.7
-16.7 -17.0 3.9 3.9 3.9 3.9 3.9 3.9
-14.7 -15.0 4.1 4.1 4.1 4.1 4.1 4.1
-12.6 -13.0 4.3 4.3 4.3 4.3 4.3 4.3
-10.5 -11.0 4.5 4.5 4.5 4.5 4.5 4.4
-9.5 -10.0 4.6 4.6 4.6 4.6 4.6 4.4
-8.5 -9.1 4.7 4.7 4.7 4.7 4.7 4.4
4.5 -7.0 -7.6 4.8 4.8 4.8 4.8 4.7 4.4
-5.0 -5.6 5.0 5.0 5.0 4.8 4.7 4.4
-3.0 -3.7 5.3 5.1 5.0 4.8 4.7 4.4
0.0 -0.7 5.3 5.2 5.0 4.8 4.7 4.4
3.0 2.2 5.5 5.3 5.0 4.8 4.7 4.4
5.0 4.1 5.6 5.3 5.0 4.8 4.7 4.4
7.0 6.0 5.6 5.3 5.0 4.8 4.7 4.4
9.0 7.9 5.6 5.3 5.0 4.8 4.7 4.4
11.0 9.8 5.6 5.3 5.0 4.8 4.7 4.4
13.0 11.8 5.6 5.3 5.0 4.8 4.7 4.4
15.0 13.7 5.6 5.3 5.0 4.8 4.7 4.4
-24.8 -25.0 3.6 3.6 3.6 3.6 3.6 3.6
-21.8 -22.0 4.4 4.4 4.4 4.4 4.4 4.4
-19.8 -20.0 4.6 4.6 4.6 4.6 4.6 4.6
-18.8 -19.0 4.8 4.7 4.7 4.7 4.7 4.7
-16.7 -17.0 5.0 5.0 5.0 4.9 4.9 4.9
-14.7 -15.0 5.2 5.2 5.2 5.2 5.2 5.2
-12.6 -13.0 5.5 5.4 5.4 5.4 5.4 5.4
-10.5 -11.0 5.7 5.7 5.7 5.7 5.7 5.5
-9.5 -10.0 5.8 5.8 5.8 5.8 5.8 5.5
-8.5 -9.1 5.9 5.9 5.9 5.9 5.9 5.5
5.6 -7.0 -7.6 6.1 6.1 6.1 6.0 5.9 5.5
-5.0 -5.6 6.3 6.3 6.3 6.1 5.9 5.5
-3.0 -3.7 6.6 6.5 6.3 6.1 5.9 5.5
0.0 -0.7 6.7 6.5 6.3 6.1 5.9 5.5
3.0 2.2 6.9 6.7 6.3 6.1 5.9 5.5
5.0 4.1 7.0 6.7 6.3 6.1 5.9 5.5
7.0 6.0 7.1 6.7 6.3 6.1 5.9 5.5
9.0 7.9 7.1 6.7 6.3 6.1 5.9 5.5
11.0 9.8 7.1 6.7 6.3 6.1 5.9 5.5
13.0 11.8 7.1 6.7 6.3 6.1 5.9 5.5
15.0 13.7 7.1 6.7 6.3 6.1 5.9 5.5

Ceiling Concealed Duct(Low Static) _ 19


6. Capacity Tables
Heating capacity

Outdoor air Indoor air temp. (DB, °C)


Capacity temp. 16 18 20 21 22 24
Index TC TC TC TC TC TC
DB(°C) WB(°C)
kW kW kW kW kW kW
-24.8 -25.0 4.1 4.1 4.0 4.0 4.0 4.0
-21.8 -22.0 4.9 4.9 4.9 4.9 4.9 4.8
-19.8 -20.0 5.2 5.2 5.1 5.1 5.1 5.1
-18.8 -19.0 5.3 5.2 5.2 5.2 5.2 5.2
-16.7 -17.0 5.5 5.5 5.5 5.5 5.5 5.5
-14.7 -15.0 5.8 5.8 5.8 5.8 5.8 5.7
-12.6 -13.0 6.1 6.0 6.0 6.0 6.0 6.0
-10.5 -11.0 6.3 6.3 6.3 6.3 6.3 6.1
-9.5 -10.0 6.5 6.5 6.4 6.4 6.4 6.1
-8.5 -9.1 6.6 6.6 6.5 6.5 6.5 6.1
-7.0 -7.6 6.8 6.7 6.7 6.7 6.6 6.1
6.2 -5.0 -5.6 7.0 7.0 7.0 6.8 6.6 6.1
-3.0 -3.7 7.4 7.2 7.0 6.8 6.6 6.1
0.0 -0.7 7.5 7.2 7.0 6.8 6.6 6.1
3.0 2.2 7.7 7.4 7.0 6.8 6.6 6.1
Indoor Units

5.0 4.1 7.8 7.4 7.0 6.8 6.6 6.1


7.0 6.0 7.9 7.4 7.0 6.8 6.6 6.1
9.0 7.9 7.9 7.4 7.0 6.8 6.6 6.1
11.0 9.8 7.9 7.4 7.0 6.8 6.6 6.1
13.0 11.8 7.9 7.4 7.0 6.8 6.6 6.1
15.0 13.7 7.9 7.4 7.0 6.8 6.6 6.1
-24.8 -25.0 4.6 4.6 4.6 4.6 4.6 4.6
-21.8 -22.0 5.6 5.6 5.6 5.6 5.6 5.5
-19.8 -20.0 5.9 5.9 5.9 5.9 5.9 5.8
-18.8 -19.0 6.0 6.0 6.0 6.0 6.0 6.0
-16.7 -17.0 6.3 6.3 6.3 6.3 6.3 6.3
-14.7 -15.0 6.6 6.6 6.6 6.6 6.6 6.6
-12.6 -13.0 6.9 6.9 6.9 6.9 6.9 6.9
-10.5 -11.0 7.2 7.2 7.2 7.2 7.2 7.0
-9.5 -10.0 7.4 7.4 7.3 7.3 7.3 7.0
-8.5 -9.1 7.5 7.5 7.5 7.5 7.5 7.0
7.1 -7.0 -7.6 7.7 7.7 7.7 7.7 7.5 7.0
-5.0 -5.6 8.0 8.0 8.0 7.7 7.5 7.0
-3.0 -3.7 8.4 8.2 8.0 7.7 7.5 7.0
0.0 -0.7 8.6 8.3 8.0 7.7 7.5 7.0
3.0 2.2 8.8 8.5 8.0 7.7 7.5 7.0
5.0 4.1 8.9 8.5 8.0 7.7 7.5 7.0
7.0 6.0 9.0 8.5 8.0 7.7 7.5 7.0
9.0 7.9 9.0 8.5 8.0 7.7 7.5 7.0
11.0 9.8 9.0 8.5 8.0 7.7 7.5 7.0
13.0 11.8 9.0 8.5 8.0 7.7 7.5 7.0
15.0 13.7 9.0 8.5 8.0 7.7 7.5 7.0

Notes:
TC: Total Capacity(kW) 3. In accordance with operation limits of outdoor unit, applicable range of
1. Capacity tables show the representative value of conditions which may occur. capacity tables is different.
2. is shown as reference. When selecting the outdoor units, avoid the 4. Refer to Capacity Correction Factor in the outdoor unit PDB for the actual
outdoor air temperature range shown by . performance data of each indoor unit and outdoor unit combination.

20 _ Ceiling Concealed Duct(Low Static)


7. External Static Pressure (E.S.P) & Air Flow
ARNU07GB1G2, ARNU09GB1G2, ARNU12GB1G2, ARNU15GB1G2 (Unit: CMM)

Static Pressure(mmAq(Pa))
Setting Value
0(0) 1(10) 2(20) 3(29) 4(39)
60 6.02 2.25 0.61 - -
65 6.95 3.32 0.73 0.54 0.48
70 7.69 5.16 1.19 0.65 0.56
75 8.46 6.93 2.42 0.77 0.63
80 9.5 7.37 3.4 0.87 0.72
85 10.35 8.72 5.33 1.35 0.88
90 10.81 9.66 6.75 3.15 0.98
95 11.57 10.31 8.56 4.73 1.03
100 12.58 11.22 9.75 7.46 2.31
105 13.31 12.27 10.89 8.64 5.01
110 14.2 13.24 12.15 10.49 7.7
115 14.82 13.92 12.64 11.16 9.48

Indoor Units
ARNU18GB2G2, ARNU24GB2G2 (Unit: CMM)
Static Pressure(mmAq(Pa))
Setting Value
0(0) 1(10) 2(20) 3(29) 4(39)
65 10.07 6.9 0.82 - -
70 11.39 8.49 2.2 - -
75 12.01 9.79 4.2 - -
80 13.21 11.03 5.92 0.92 -
85 14.24 12.36 9.41 2.1 -
90 15.04 13.34 10.8 5.29 1.01
95 16.02 14.63 12.5 7.59 1.34
100 17.11 15.56 13.66 11.53 5.35
105 17.99 16.53 15.17 12.35 7.67
110 19.04 17.71 16.22 14.23 10.45
115 19.77 18.62 17.1 15.23 13.25
120 20.94 19.92 18.56 16.98 14.66
125 21.97 20.56 19.25 17.68 16.06
130 22.83 21.98 20.75 19.32 17.73

Note :
1. The above table shows the correlation between the air rates and E.S.P.

Ceiling Concealed Duct(Low Static) _ 21


7. External Static Pressure (E.S.P) & Air Flow
(Unit : CMM)
ARNU05GL1G2, ARNU07GL1G2, ARNU09GL1G2
Static Pressure(mmAq(Pa))
Setting Value
0 (0) 1 (10) 2 (20) 3 (29) 4 (39) 5 (49)
60 - - - - - -
65 5.03 - - - - -
70 5.60 4.85 - - - -
75 6.19 5.44 4.57 - - -
80 6.79 6.05 5.17 - - -
85 7.41 6.67 5.80 4.80 - -
90 8.05 7.31 6.43 5.44 - -
95 8.71 7.96 7.09 6.09 4.97 -
100 9.38 8.63 7.76 6.76 5.64 -
105 10.07 9.32 8.45 7.45 6.33 5.08
110 - 10.03 9.16 8.16 7.04 5.79
115 - - 9.88 8.88 7.76 6.51
120 - - - 9.62 8.50 7.25
125 - - - 10.38 9.26 8.01
Indoor Units

130 - - - - 10.03 8.78

ARNU12GL2G2, ARNU15GL2G2, ARNU18GL2G2 (Unit : CMM)

Static Pressure(mmAq(Pa))
Setting Value
0 (0) 1 (10) 2 (20) 3 (29) 4 (39) 5 (49)
75 6.50 - - - - -
80 7.34 6.70 - - - -
85 8.20 7.55 6.69 - - -
90 9.07 8.43 7.56 6.47 - -
95 9.96 9.32 8.45 7.36 - -
100 10.87 10.22 9.36 8.27 6.96 -
105 11.79 11.15 10.28 9.19 7.89 6.35
110 12.73 12.09 11.22 10.14 8.83 7.30
115 13.69 13.05 12.18 11.09 9.78 8.25
120 14.67 14.02 13.16 12.07 10.76 9.23
125 15.66 15.01 14.15 13.06 11.75 10.22
130 16.67 16.02 15.16 14.07 12.76 11.23
135 - - 16.18 15.10 13.79 12.26
Note :
1. The above table shows the correlation between the air rates and E.S.P.

22 _ Ceiling Concealed Duct(Low Static)


7. External Static Pressure (E.S.P) & Air Flow
ARNU21GL3G2, ARNU24GL3G2 (Unit : CMM)

Static Pressure(mmAq(Pa))
Setting Value
0 (0) 1 (10) 2 (20) 3 (29) 4 (39) 5 (49)
85 10.19 - - - - -
90 12.18 10.71 11.09 - - -
95 13.81 12.34 12.19 - - -
100 15.16 13.69 13.38 10.71 - -
105 16.30 14.83 14.36 11.85 - -
110 17.31 15.85 15.23 12.86 10.97 -
115 18.27 16.80 16.07 13.82 11.93 -
120 19.26 17.79 16.93 14.80 12.91 10.49
125 20.34 18.87 17.89 15.88 13.99 11.57
130 21.60 20.13 19.01 17.14 15.25 12.83
135 - 21.64 20.36 18.66 16.76 14.35
139 - - 21.08 19.05 17.34 15.29

Indoor Units
Note :
1. The above table shows the correlation between the air rates and E.S.P.

Ceiling Concealed Duct(Low Static) _ 23


7. External Static Pressure (E.S.P) & Air Flow
ARNU07GB1G2, ARNU09GB1G2, ARNU12GB1G2, ARNU15GB1G2
Standard Lower Limit of External Upper Limit of External
Capacity Mode Set value ESP(mmAq(Pa)) CMM Static Pressure(mmAq(Pa)) Static Pressure(mmAq(Pa))

High HI 94 8.5
Mid 92 2(20) 7.5 - 4(39)
(factory set) Low 86 6.5
7k
HI 75 8.5
Standard Mid 69 0(0) 7.5 - 4(39)
Low 62 6.5
High HI 99 9.5
Mid 94 2(20) 8.5 - 4(39)
(factory set) Low 92 7.5
9k
HI 82 9.5
Standard Mid 75 0(0) 8.5 - 4(39)
Low 69 7.5
High HI 103 10.5
Mid 99 2(20) 9.5 - 4(39)
(factory set) Low 94 8.5
12k HI 89 10.5
Standard Mid 80 0(0) 9.5 - 4(39)
Indoor Units

Low 75 8.5
High HI 107 11.5
Mid 105 2(20) 10.5 - 4(39)
(factory set) Low 99 9.5
15k HI 95 11.5
Standard Mid 89 0(0) 10.5 - 4(39)
Low 82 9.5

ARNU18GB2G2, ARNU24GB2G2
Standard Lower Limit of External Upper Limit of External
Capacity Mode Set value ESP(mmAq(Pa)) CMM Static Pressure(mmAq(Pa)) Static Pressure(mmAq(Pa))

High HI 110 16.0


Mid 101 2(20) 14.0 - 4(39)
(factory set)
18k Low 93 12.0
HI 95 16.0
Standard Mid 84 0(0) 14.0 - 4(39)
Low 75 12.0
High HI 125 19.0
Mid 115 2(20) 17.0 - 4(39)
(factory set) Low 105 15.0
24k
HI 110 19.0
Standard Mid 100 0(0) 17.0 - 4(39)
Low 90 15.0

24 _ Ceiling Concealed Duct(Low Static)


7. External Static Pressure (E.S.P) & Air Flow
ARNU05GL1G2, ARNU07GL1G2, ARNU09GL1G2
Lower Limit of Upper Limit of
Standard
Capacity Mode Set value CMM External Static External Static
ESP(mmAq(Pa))
Pressure(mmAq(Pa)) Pressure(mmAq(Pa))
HI 96 6.7
High
Mid 91 2.54 (25) 6.2 - 5(49)
(factory set)
Low 86 5.5
5k
HI 79 6.7
Standard Mid 74 0 (0) 6.2 - 5(49)
Low 69 5.5
HI 100 7.5
High
Mid 93 2.54 (25) 6.5 - 5(49)
(factory set)
Low 86 5.5
7k
HI 86 7.5
Standard Mid 78 0 (0) 6.5 - 5(49)
Low 69 5.5
HI 113 9.0
High
Mid 97 2.54 (25) 7.0 - 5(49)
(factory set)

Indoor Units
Low 86 5.5
9k
HI 97 9.0
Standard Mid 81 0 (0) 7.0 - 5(49)
Low 69 5.5

ARNU12GL2G2, ARNU15GL2G2, ARNU18GL2G2


Lower Limit of Upper Limit of
Standard
Capacity Mode Set value CMM External Static External Static
ESP(mmAq(Pa))
Pressure(mmAq(Pa)) Pressure(mmAq(Pa))
HI 105 10.0
High
Mid 96 2.54 (25) 8.5 - 5(49)
(factory set)
Low 89 7.0
12k
HI 96 10.0
Standard Mid 87 0 (0) 8.5 - 5(49)
Low 78 7.0
HI 119 12.5
High
Mid 105 2.54 (25) 10.0 - 5(49)
(factory set)
Low 96 8.5
15k
HI 109 12.5
Standard Mid 96 0 (0) 10.0 - 5(49)
Low 87 8.5
HI 131 15.0
High
Mid 119 2.54 (25) 12.5 - 5(49)
(factory set)
Low 105 10.0
18k
HI 120 15.0
Standard Mid 109 0 (0) 12.5 - 5(49)
Low 96 10.0

Ceiling Concealed Duct(Low Static) _ 25


7. External Static Pressure (E.S.P) & Air Flow
ARNU21GL3G2, ARNU24GL3G2
Lower Limit of Upper Limit of
Standard
Capacity Mode Set value CMM External Static External Static
ESP(mmAq(Pa))
Pressure(mmAq(Pa)) Pressure(mmAq(Pa))
HI 125 17.5
High
Mid 110 2.54 (25) 14.0 - 5(49)
(factory set)
Low 105 12.0
21k
HI 113 17.5
Standard Mid 95 0 (0) 14.0 - 5(49)
Low 89 12.0
HI 139 20.0
High
Mid 118 2.54 (25) 16.0 - 5(49)
(factory set)
Low 105 12.0
24k
HI 125 20.0
Standard Mid 102 0 (0) 16.0 - 5(49)
Low 89 12.0
Indoor Units

26 _ Ceiling Concealed Duct(Low Static)


8. Electric Characteristics
Units Power Supply IFM Input(W)
Model Type Hz Volts Voltage Range MCA MFA kW FLA Cooling Heating
ARNU07GB1G2 B1 0.22 15 0.028 0.17 30 30
ARNU09GB1G2 B1 0.22 15 0.028 0.17 30 30
ARNU12GB1G2 B1 0.22 15 0.028 0.17 30 30
ARNU15GB1G2 B1 0.22 15 0.028 0.17 30 30
ARNU18GB2G2 B2 0.55 15 0.076 0.44 80 80
ARNU24GB2G2 B2 0.55 15 0.076 0.44 80 80
ARNU05GL1G2 L1 Max:264 0.50 15 0.019 0.40 40 40
50 220-240
ARNU07GL1G2 L1 Min:198 0.50 15 0.019 0.40 40 40
ARNU09GL1G2 L1 0.50 15 0.019 0.40 40 40
ARNU12GL2G2 L2 0.85 15 0.024 0.70 85 85
ARNU15GL2G2 L2 0.85 15 0.024 0.70 85 85
ARNU18GL2G2 L2 0.85 15 0.024 0.70 85 85
ARNU21GL3G2 L3 1.15 15 0.038 0.90 115 115

Indoor Units
ARNU24GL3G2 L3 1.15 15 0.038 0.90 115 115
ARNU07GB1G2 B1 0.22 15 0.028 0.17 30 30
ARNU09GB1G2 B1 0.22 15 0.028 0.17 30 30
ARNU12GB1G2 B1 0.22 15 0.028 0.17 30 30
ARNU15GB1G2 B1 0.22 15 0.028 0.17 30 30
ARNU18GB2G2 B2 0.55 15 0.076 0.44 80 80
ARNU24GB2G2 B2 0.55 15 0.076 0.44 80 80
ARNU05GL1G2 L1 Max:242 0.50 15 0.019 0.40 40 40
60 220
ARNU07GL1G2 L1 Min:198 0.50 15 0.019 0.40 40 40
ARNU09GL1G2 L1 0.50 15 0.019 0.40 40 40
ARNU12GL2G2 L2 0.85 15 0.024 0.70 85 85
ARNU15GL2G2 L2 0.85 15 0.024 0.70 85 85
ARNU18GL2G2 L2 0.85 15 0.024 0.70 85 85
ARNU21GL3G2 L3 1.15 15 0.038 0.90 115 115
ARNU24GL3G2 L3 1.15 15 0.038 0.90 115 115

Symbols: Note :
MCA : Min, Circuit Amps(A) 1. Voltage range
MFA : Max. Fuse Amps(see note 5) Units are suitable for use on electrical systems
kW : Fan Motor Rated Output(kW) where voltage supplied to unit terminals is not below
FLA : Full Load Amps(A) or above the listed range limits,
IFM : Indoor Fan Motor 2. Maximum allowable voltage unbalance between
phases is 2%
3. MCA/MFA
MCA=1.25 x FLA
MFA≤ 4 x FLA
(Next lower standard fuse rating. Min. 15A)
4. Select wire size based on the MCA
5. Instead of fuse, use Circuit Breaker.

Ceiling Concealed Duct(Low Static) _ 27


9. Sound Levels
9.1 B1/B2 Chassis
Overall
Notes:
DISCHARGE SUCTION 1. Sound measured at 1.5m away from the center of the unit
2. Operating condition
DUCT DUCT - Power source : 220-240V 50Hz / 220V 60Hz
- Cooling : Indoor temperature (27°C DB, 19°C WB),
1.5m Outdoor temperature (35°C DB, 24°C WB)
2m 1m - Heating : Indoor temperature (20°C DB, 15°C WB),
Outdoor temperature (7°C DB, 6°C WB)
3. Reference accoustic pressure 0dB = 20μPa
4. Sound level will vary depending on a range of factors such as the
❈ Measuring place : Anechoic chamber construction(acoustic absorption coefficient) of particular room in
which the equipment in installed.
5. The operating condition is external static pressure 20Pa.
Sound Levels dB(A)
Model Name
H M L
ARNU07GB1G2 29 26 24
ARNU09GB1G2 31 29 26
ARNU12GB1G2 33 30 29
ARNU15GB1G2 34 33 31
Indoor Units

ARNU18GB2G2 40 37 34
ARNU24GB2G2 43 40 37

Sound Pressure Level


ARNU07GB1G2 ARNU09GB1G2 ARNU12GB1G2
80 80 80

70 70 70
Octave Band Sound Pressure Level (0 dB = 20 μPa)

Octave Band Sound Pressure Level (0 dB = 20 μPa)

Octave Band Sound Pressure Level (0 dB = 20 μPa)


NC-65 NC-65 NC-65
60 60 60
NC-60 NC-60 NC-60

NC-55 NC-55 NC-55


50 50 50
NC-50 NC-50 NC-50

NC-45 NC-45 NC-45


40 40 40
NC-40 NC-40 NC-40

NC-35 NC-35 NC-35


30 30 30
NC-30 NC-30 NC-30

NC-25 NC-25 NC-25


20 20 20
Approximate
Approximate
NC-20
Approximate
Approximate NC-20
Approximate
Approximate NC-20
Hearing
Hearing Hearing
Hearing Hearing
Hearing
Threshold
Threshold Threshold Threshold
NC-15 Threshold NC-15 Threshold NC-15
10 10 10
63 125 250 500 1 000 2 000 4 000 8 000 63 125 250 500 1 000 2 000 4 000 8 000 63 125 250 500 1 000 2 000 4 000 8 000
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

ARNU15GB1G2 ARNU18GB2G2 ARNU24GB2G2


80 80 80

70 70 70
Octave Band Sound Pressure Level (0 dB = 20 μPa)
Octave Band Sound Pressure Level (0 dB = 20 μPa)

Octave Band Sound Pressure Level (0 dB = 20 μPa)

NC-65 NC-65 NC-65


60 60 60
NC-60 NC-60 NC-60

NC-55 NC-55 NC-55


50 50 50
NC-50 NC-50 NC-50

NC-45 NC-45 NC-45


40 40 40
NC-40 NC-40 NC-40

NC-35 NC-35 NC-35


30 30 30
NC-30 NC-30 NC-30

NC-25 NC-25 NC-25


20 20 20
Approximate Approximate
Approximate Approximate
Approximate
Approximate NC-20 NC-20 NC-20
Hearing Hearing
Hearing Hearing
Hearing
Hearing
Threshold Threshold
Threshold Threshold
Threshold
Threshold NC-15 NC-15 NC-15
10 10 10
63 125 250 500 1 000 2 000 4 000 8 000 63 125 250 500 1 000 2 000 4 000 8 000 63 125 250 500 1 000 2 000 4 000 8 000
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

28 _ Ceiling Concealed Duct(Low Static)


9. Sound Levels
9.2 L1/L2/L3 Chassis
Overall
Notes:
DISCHARGE SUCTION 1. Sound measured at 1.5m away from the center of the unit
2. Operating condition
DUCT DUCT - Power source : 220-240V 50Hz / 220V 60Hz
- Cooling : Indoor temperature (27°C DB, 19°C WB),
Outdoor temperature (35°C DB, 24°C WB)
1.5m - Heating : Indoor temperature (20°C DB, 15°C WB),
2m 2m Outdoor temperature (7°C DB, 6°C WB)
3. Reference accoustic pressure 0dB = 20μPa
4. Sound level will vary depending on a range of factors such as the
construction(acoustic absorption coefficient) of particular room in
which the equipment in installed.
❈ Measuring place : Anechoic chamber
5. The operating condition is external static pressure 20Pa.

Sound Pressure Levels (dB(A),H-M-L)


Model External Static Pressure (Pa)
10 20 50

Indoor Units
ARNU05GL1G2 24-22-21 25-24-22 29-28-27
ARNU07GL1G2 25-22-21 26-24-22 31-29-27
ARNU09GL1G2 27-24-21 28-25-22 32-30-27
ARNU12GL2G2 28-26-24 30-27-25 34-32-30
ARNU15GL2G2 32-28-26 33-30-28 36-34-32
ARNU18GL2G2 34-31-28 35-32-29 38-36-34
ARNU21GL3G2 33-28-27 35-29-28 38-36-34
ARNU24GL3G2 35-32-27 36-33-28 39-36-34

Sound Pressure Level (10Pa)


ARNU05GL1G2 ARNU07GL1G2 ARNU09GL1G2
80 80 80

n High n High n High


▲ Mid ▲ Mid ▲ Mid
70 l Low 70 l Low 70 l Low
Octave Band Sound Pressure Level (0 dB = 20 μPa)

Octave Band Sound Pressure Level (0 dB = 20 μPa)

Octave Band Sound Pressure Level (0 dB = 20 μPa)

NC-65 NC-65 NC-65


60 60 60
NC-60 NC-60 NC-60

NC-55 NC-55 NC-55


50 50 50
NC-50 NC-50 NC-50

NC-45 NC-45 NC-45


40 40 40
NC-40 NC-40 NC-40

NC-35 NC-35 NC-35


30 30 30
NC-30 NC-30 NC-30

NC-25 NC-25 NC-25


20 20 20
Approximate Approximate Approximate
NC-20 NC-20 NC-20
Hearing Hearing Hearing
Threshold Threshold Threshold
NC-15 NC-15 NC-15
10 10 10
63 125 250 500 1 000 2 000 4 000 8 000 63 125 250 500 1 000 2 000 4 000 8 000 63 125 250 500 1 000 2 000 4 000 8 000
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

Ceiling Concealed Duct(Low Static) _ 29


9. Sound Levels
ARNU12GL2G2 ARNU15GL2G2 ARNU18GL2G2
80 80 80

n High n High n High


▲ Mid ▲ Mid ▲ Mid
70 l Low 70 l Low 70 l Low

Octave Band Sound Pressure Level (0 dB = 20 μPa)


Octave Band Sound Pressure Level (0 dB = 20 μPa)

Octave Band Sound Pressure Level (0 dB = 20 μPa)


NC-65 NC-65 NC-65
60 60 60
NC-60 NC-60 NC-60

NC-55 NC-55 NC-55


50 50 50
NC-50 NC-50 NC-50

NC-45 NC-45 NC-45


40 40 40
NC-40 NC-40 NC-40

NC-35 NC-35 NC-35


30 30 30
NC-30 NC-30 NC-30

NC-25 NC-25 NC-25


20 20 20
Approximate Approximate Approximate
NC-20 NC-20 NC-20
Hearing Hearing Hearing
Threshold Threshold Threshold
NC-15 NC-15 NC-15
10 10 10
63 125 250 500 1 000 2 000 4 000 8 000 63 125 250 500 1 000 2 000 4 000 8 000 63 125 250 500 1 000 2 000 4 000 8 000
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

ARNU21GL3G2 ARNU24GL3G2
Indoor Units

80 80
n High n High
▲ Mid ▲ Mid
70 l Low 70 l Low
Octave Band Sound Pressure Level (0 dB = 20 μPa)

Octave Band Sound Pressure Level (0 dB = 20 μPa)

NC-65 NC-65
60 60
NC-60 NC-60

NC-55 NC-55
50 50
NC-50 NC-50

NC-45 NC-45
40 40
NC-40 NC-40

NC-35 NC-35
30 30
NC-30 NC-30

NC-25 NC-25
20 20
Approximate Approximate
NC-20 NC-20
Hearing Hearing
Threshold Threshold
NC-15 NC-15
10 10
63 125 250 500 1 000 2 000 4 000 8 000 63 125 250 500 1 000 2 000 4 000 8 000
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

Sound Pressure Level (20Pa)


ARNU05GL1G2 ARNU07GL1G2 ARNU09GL1G2
80 80 80

n High n High n High


▲ Mid ▲ Mid ▲ Mid
70 l Low 70 l Low 70 l Low
Octave Band Sound Pressure Level (0 dB = 20 μPa)

Octave Band Sound Pressure Level (0 dB = 20 μPa)

Octave Band Sound Pressure Level (0 dB = 20 μPa)

NC-65 NC-65 NC-65


60 60 60
NC-60 NC-60 NC-60

NC-55 NC-55 NC-55


50 50 50
NC-50 NC-50 NC-50

NC-45 NC-45 NC-45


40 40 40
NC-40 NC-40 NC-40

NC-35 NC-35 NC-35


30 30 30
NC-30 NC-30 NC-30

NC-25 NC-25 NC-25


20 20 20
Approximate Approximate Approximate
NC-20 NC-20 NC-20
Hearing Hearing Hearing
Threshold Threshold Threshold
NC-15 NC-15 NC-15
10 10 10
63 125 250 500 1 000 2 000 4 000 8 000 63 125 250 500 1 000 2 000 4 000 8 000 63 125 250 500 1 000 2 000 4 000 8 000
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

30 _ Ceiling Concealed Duct(Low Static)


9. Sound Levels
ARNU12GL2G2 ARNU15GL2G2 ARNU18GL2G2
80 80 80

n High n High n High


▲ Mid ▲ Mid ▲ Mid
70 l Low 70 l Low 70 l Low

Octave Band Sound Pressure Level (0 dB = 20 μPa)


Octave Band Sound Pressure Level (0 dB = 20 μPa)

Octave Band Sound Pressure Level (0 dB = 20 μPa)


NC-65 NC-65 NC-65
60 60 60
NC-60 NC-60 NC-60

NC-55 NC-55 NC-55


50 50 50
NC-50 NC-50 NC-50

NC-45 NC-45 NC-45


40 40 40
NC-40 NC-40 NC-40

NC-35 NC-35 NC-35


30 30 30
NC-30 NC-30 NC-30

NC-25 NC-25 NC-25


20 20 20
Approximate Approximate Approximate
NC-20 NC-20 NC-20
Hearing Hearing Hearing
Threshold Threshold Threshold
NC-15 NC-15 NC-15
10 10 10
63 125 250 500 1 000 2 000 4 000 8 000 63 125 250 500 1 000 2 000 4 000 8 000 63 125 250 500 1 000 2 000 4 000 8 000
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

ARNU21GL3G2 ARNU24GL3G2

Indoor Units
80 80
n High n High
▲ Mid ▲ Mid
70 l Low 70 l Low
Octave Band Sound Pressure Level (0 dB = 20 μPa)

Octave Band Sound Pressure Level (0 dB = 20 μPa)

NC-65 NC-65
60 60
NC-60 NC-60

NC-55 NC-55
50 50
NC-50 NC-50

NC-45 NC-45
40 40
NC-40 NC-40

NC-35 NC-35
30 30
NC-30 NC-30

NC-25 NC-25
20 20
Approximate Approximate
NC-20 NC-20
Hearing Hearing
Threshold Threshold
NC-15 NC-15
10 10
63 125 250 500 1 000 2 000 4 000 8 000 63 125 250 500 1 000 2 000 4 000 8 000
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

Sound Pressure Level (50Pa)


ARNU05GL1G2 ARNU07GL1G2 ARNU09GL1G2
80 80 80

n High n High n High


▲ Mid ▲ Mid ▲ Mid
70 l Low 70 l Low 70 l Low
Octave Band Sound Pressure Level (0 dB = 20 μPa)

Octave Band Sound Pressure Level (0 dB = 20 μPa)

Octave Band Sound Pressure Level (0 dB = 20 μPa)

NC-65 NC-65 NC-65


60 60 60
NC-60 NC-60 NC-60

NC-55 NC-55 NC-55


50 50 50
NC-50 NC-50 NC-50

NC-45 NC-45 NC-45


40 40 40
NC-40 NC-40 NC-40

NC-35 NC-35 NC-35


30 30 30
NC-30 NC-30 NC-30

NC-25 NC-25 NC-25


20 20 20
Approximate Approximate Approximate
NC-20 NC-20 NC-20
Hearing Hearing Hearing
Threshold Threshold Threshold
NC-15 NC-15 NC-15
10 10 10
63 125 250 500 1 000 2 000 4 000 8 000 63 125 250 500 1 000 2 000 4 000 8 000 63 125 250 500 1 000 2 000 4 000 8 000
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

Ceiling Concealed Duct(Low Static) _ 31


9. Sound Levels
ARNU12GL2G2 ARNU15GL2G2 ARNU18GL2G2
80 80 80

n High n High n High


▲ Mid ▲ Mid ▲ Mid
70 l Low 70 l Low 70 l Low

Octave Band Sound Pressure Level (0 dB = 20 μPa)


Octave Band Sound Pressure Level (0 dB = 20 μPa)

Octave Band Sound Pressure Level (0 dB = 20 μPa)


NC-65 NC-65 NC-65
60 60 60
NC-60 NC-60 NC-60

NC-55 NC-55 NC-55


50 50 50
NC-50 NC-50 NC-50

NC-45 NC-45 NC-45


40 40 40
NC-40 NC-40 NC-40

NC-35 NC-35 NC-35


30 30 30
NC-30 NC-30 NC-30

NC-25 NC-25 NC-25


20 20 20
Approximate Approximate Approximate
NC-20 NC-20 NC-20
Hearing Hearing Hearing
Threshold Threshold Threshold
NC-15 NC-15 NC-15
10 10 10
63 125 250 500 1 000 2 000 4 000 8 000 63 125 250 500 1 000 2 000 4 000 8 000 63 125 250 500 1 000 2 000 4 000 8 000
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

ARNU21GL3G2 ARNU24GL3G2
Indoor Units

80 80
n High n High
▲ Mid ▲ Mid
70 l Low 70 l Low
Octave Band Sound Pressure Level (0 dB = 20 μPa)

Octave Band Sound Pressure Level (0 dB = 20 μPa)

NC-65 NC-65
60 60
NC-60 NC-60

NC-55 NC-55
50 50
NC-50 NC-50

NC-45 NC-45
40 40
NC-40 NC-40

NC-35 NC-35
30 30
NC-30 NC-30

NC-25 NC-25
20 20
Approximate Approximate
NC-20 NC-20
Hearing Hearing
Threshold Threshold
NC-15 NC-15
10 10
63 125 250 500 1 000 2 000 4 000 8 000 63 125 250 500 1 000 2 000 4 000 8 000
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

32 _ Ceiling Concealed Duct(Low Static)


10. Installation
• Please read the instruction sheets completely before installing the product.
• When the power cord is damaged, replacement work shall be performed by authorized personnel only.
• Installation work must be performed in accordance with the national wiring standards by authorized personnel only.

B1/B2 Chassis

L1/L2/L3 Chassis

Indoor Units
Required Parts Required Tools
• Connecting cable • Level
• Pipes: Gas side • Screw driver
Liquid side • Electric drill
• Hanging Bolt • Hole core drill
(W 3/8 or M10 length 650mm)
• Flaring Tool set
• Insulated drain hose
• Torque Wrenches
• Additional Drain hose
• Hexagonal Wrench
• Gas-leak detector
• Thermometer

Ceiling Concealed Duct(Low Static) _ 33


10. Installation
10.1 Selection of the best location Top view (Unit: mm)
Install the air conditioner in the location that satisfies the
following conditions.
• The place shall easily bear a load exceeding four times
the indoor unitʼs weight.
• The place shall be able to inspect the unit as given in
the
figure.
Control box
• The place where the unit shall be leveled. 600
Inspection hole 600
• The place shall allow easy water drainage.(Suitable (600 x 600)
dimension “H” is necessary to get a slope to drain as
figure.)
• The place shall easily connect with the outdoor unit. Side view (unit: mm)
• The place where the unit is not affected by an electrical
noise.
• The place where air circulation in the room will be good
Indoor Units

.
• There should not be any heat source or steam near the
unit.
H=20 or more
• The servicing inspection hole in the ceiling should be as
large as the product. • Suitable dimension "H" is necessary to get a slope
• The selection of the servicing hole should be approved to drain as shown in the figure
by the customer.

[B1 / B2 Chassis]
(Unit: mm)
Capacity (kBtu/h) A B
7/9/12/15 600 900
18/24 600 1100 B(Min)
A(Min)

[L1 / L2 / L3 Chassis] (Unit: mm)


Capacity (kBtu/h) A B
5/7/9 800 800
12/15/18 800 1000 Ceiling
21/24 800 1200 Service Space

34 _ Ceiling Concealed Duct(Low Static)


10. Installation
10.2 Ceiling dimension and hanging bolt location
n Installation of Unit
Install the unit above the ceiling correctly.

CASE 1
POSITION OF SUSPENSION BOLT
• Apply a joint-canvas between the unit and duct to
absorb unnecessary vibration.
• Install the unit leaning to a drainage hole side as E
a figure for easy water drainage. G

CASE 2 D C

POSITION OF CONSOLE BOLT

Indoor Units
• A place where the unit will be leveled and that can sup-
J
port the weight of the unit. A
• A place where the unit can withstand its vibration. B
• A place where service can be easily performed.
(Unit:mm)
Dimension
F
I

A B C D E F G H I J
Capacity(kBtu/h)
H
5/7/9 733 772 628 700 36 190 20 660 155 700
12/15/18 933 972 628 700 36 190 20 860 155 900
21/24 1133 1172 628 700 36 190 20 1060 155 1100 Drainage hole

M10 Nut X4 M10 Nut X4


M10 washer X4 M10 washer X4

M10 washer X4 M10 washer X4


M10 Nut X8 M10 Nut X8

Ceiling Concealed Duct(Low Static) _ 35


10. Installation
Note:
• Throughly study the following installation locations:
1. In such places as restaurants and kitchens, considerable amount of oil steam and flour adhere to the fan, the fin of
the heat exchanger, resulting in heat exchange reduction, spraying, dispersing of water drops, etc.
In these cases, take the following actions:
• Make sure that the ventilation fan for smoke-collecting hood on a cooking table has sufficient capacity so that it
draws oily steam which should not flow into the suction of the air conditioner.
• Make enough distance from a cooking room to install the air conditioner in such a place where it may not suck in
oil steam.
2. Avoid installing air conditioner in such circumstances where cutting oil mist or iron powder is in suspension in fac-
tories, etc.
3. Avoid places where inflammable gas is generated, flows in, is stored or vented.
4. Avoid places where sulfurous acid gas or corrosive gas is generated.
5. Avoid places near high frequency generators.
Indoor Units

10.3 Indoor Unit Installation


• Select and mark the position for fixing bolts. • Insert the set anchor and washer onto the suspen-
• Drill the hole for set anchor on the face of ceiling. sion bolts for locking the suspension bolts on the
ceiling.
• Mount the suspension bolts to the set anchor firmly.
• Secure the installation plates onto the suspension
bolts (adjust level roughly) using nuts, washers
and spring washers.
Old building New building

1 Set anchor
2 Plate washer
3 Spring washer
CAUTION : Tighten the nut and bolt 4 Nut
to prevent unit falling. 5 Suspension
bolts

36 _ Ceiling Concealed Duct(Low Static)


10. Installation
10.4 Connecting Cables
Connect the wires to the terminals on the control board individually according to the outdoor unit connection.
• Ensure that the color of the wires of outdoor unit and the terminal No. are the same as those of indoor unit respectively

B1/B2 Chassis
[Type 1]
Terminal Block Indoor SODU B SODU A IDU B IDU A INT B INT A
1(L) 2(N) 3 4

INDOOR POWER INPUT

[Type 2]
Terminal Block Indoor SODU IDU INTERNET DRY1 DRY2 GND 12V Outdoor
1(L) 2(N) 3 4 Unit
B A - - B A - - - -

Indoor Units
INDOOR POWER INPUT

L1/L2/L3 Chassis
Indoor unit Outdoor unit
[Type 1]
Terminal Block Indoor Terminal Block Indoor Outdoor unit Indoor unit Central controller
1(L) 2(N) 3(A) 4(B) SODU SODU IDU IDU INTERNET DRY1 DRY2 GND 12V

INDOOR POWER INPUT [Type 2]


Terminal block of outdoor unit
POWER Comm.
AC 220 V DC 12 V Central controller Indoor unit Outdoor unit
12V GND DRY2 DRY1 CEN CEN IDU IDU SODU SODU

Clamping of cables
1) Arrange 2 power cables on the control panel.
2) First, fasten the steel clamp with a screw to the inner boss of control panel.
3) For the cooling model, fix the other side of the clamp with a screw strongly. For the heat pump model, put the
0.75mm2 cable(thinner cable) on the clamp and tighten it with a plastic clamp to the other boss of the control panel.

10.5 Checking the Drainage


• Spray one or two glasses of water on the evaporator.
• Ensure that water flows drain hose of indoor unit without any leakage.

Ceiling Concealed Duct(Low Static) _ 37


10. Installation
10.6 Indoor Unit Drain Piping
Upward
• Drain piping must have down-slope (1/50 to 1/100): be sure Pipe clamp
routing
not to provide up-and-down slope to prevent reversal flow. not allowed
• During drain piping connection, be careful not to exert extra Indoor unit
force on the drain port on the indoor unit.
• The outside diameter of the drain connection on the indoor
unit is 32mm. Maintenance
drain port
Piping material: Polyvinyl chloride pipe inner
diometes Ø 25mm and pipe fittings

• Be sure to install heat insulation on the drain piping. 1/50~1/100


MAX 700mm
Heat insulation material: Polyethylene foam with
thickness more than 8 mm.
Indoor Units

Drain test

The air conditioner uses a drain pump to drain water.


Use the following procedure to test the drain pump operation:

Feed water Flexible drain hose • Connect the main drain pipe to the exterior and leave it pro-
(accessory) visionally until the test comes to an end.
Main • Feed water to the flexible drain hose and check the piping
drain pipe
for leakage.
Drain • Be sure to check the drain pump for normal operating and
Drain Pump port Glue the joint noise when electrical wiring is complete.
Drain hose connection • When the test is complete, connect the flexible drain hose to
Use the clip (accessory) the drain port on the indoor unit.

Drain pan
Hanger
Max 300mm distance Hanger Bracket
CAUTION 1~15m 1/50~1/100 slope
Metal
Max 700mm

The supplied flexible drain hose should not be strained. clamp


A strained hose may cause leakage of water.
Flexible drain hose
Insulation

Flexible
Flexible drain
drain hose
hose

Flexible drain hose

38 _ Ceiling Concealed Duct(Low Static)


10. Installation
10.7 Ground drain piping
a) It is standard work practice to make connections to the main pipe from above. The pipe down from the
combination should be as large as possible.

Face the vent pipe mouth downward to keep


foreign matter from penetrating the system

Face piping
downward

Indoor Units
Vent pipe

b) The pipe work should be kept as short as possible and the number of indoor units per group kept to a
minimum.

10.8 Use of an auxiliary drain hose(flexible)


a) To connect drain pipe to the drain socket on the indoor unit, an auxiliary flexible drain hose should be
used. auxiliary flexible drain hose allows that the drain pipe can be connected to the socket without break-
ing by excessive strain.

Auxiliary drain hose


Thermal insulation (drain pipe area)

Metal clamp

Metal clamp
Thermal insulation(bend area)

Drain pan

h Important points
- The drain pipe should be at least equal in size to that of the indoor unit.
- The drain pipe is thermally insulated to prevent the formation of condensation inside the pipe.
- The drain up mechanism should be fitted before the indoor unit is installed and when the electricity has
been connected some water should be added to the drain pan and the drain pump to check and see if it
is functioning correctly.
- All connections should be secure. (Special care is needed with PVC pipe)
- Insulate auxiliary drain hose with thermal insulation band.

Ceiling Concealed Duct(Low Static) _ 39


10. Installation
WIRED REMOTE CONTROLLER INSTALLATION
• Since the room temperature sensor is in the remote controller, the remote controller box should be installed in a place
away from direct sunlight, high humidity and direct supply of cold air to maintain proper space temperature.
Install the remote controller about 5ft(1.5m) above the floor in an area with good air circulation at an average temperature.
Do not install the remote controller where it can be affected by:
- Drafts, or dead spots behind doors and in corners.
- Hot or cold air from ducts.
- Radiant heat from sun or appliances.
- Concealed pipes and chimneys.
- Uncontrolled areas such as an outside wall behind the remote controller.
- This remote controller is equipped with a seven segment LED. display. For proper display of the remote controller
LED's, the remote controller should be installed properly as shown in Fig.1.
(The standard height is 1.2~1.5 m from floor level.)
Indoor Units

Remote Controller
TEMP
yes

no
TEMP

Remote Controller

no
TEMP
5feet
Remote
Controller

(1.5meters)

no

Fig.1 Typical locations for remote controller

40 _ Ceiling Concealed Duct(Low Static)


11. Accessories
Standard Accessories
Washer for Clamp Insulation for
Name Drain hose Clamp metal (Other)
hanging backet (Tie Wrap) fitting

Quantity 1 EA 2 EA 8 EA 4 EA 1 SET

• Owner's manual
• Installation manual

Shape for gas pipe

for liquid pipe

Indoor Units
CAUTION
• Use only those accessories (Standard or optional) which have designated specifications.

Ceiling Concealed Duct(Low Static) _ 41


Indoor unit
Ceiling Concealed Duct_Built in (Low Static)
1. List of functions

2. Specifications

3. Dimensions

4. Piping Diagrams

5. Wiring Diagrams

6. Capacity Tables

7. External Static Pressure (E.S.P) & Air Flow

8. Electric Characteristics

9. Sound Levels

10. Installation

11. Accessories
1. List of Functions
ARNU07GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y)
ARNU09GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y)
Category Function ARNU12GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y)
ARNU15GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y)
ARNU18GB4G2+PBSGB40(Acc'y), PBSC40(Acc'y)
ARNU24GB4G2+PBSGB40(Acc'y), PBSC40(Acc'y)
Air supply outlet 1
Airflow direction control(left & right) -
Airflow direction control(up & down) -
Auto swing(left & right) -
Auto swing(up & down) -
Air flow
Airflow steps(fan/cool/heat) 3/3/3
Chaos swing -
Chaos wind(auto wind) -
Jet cool(Power wind) -
Swirl wind -
Deodorizing filter X
Air purifying Plasma air purifier X
Prefilter(washable / anti-fungus) O
Drain pump O

Indoor Units
E.S.P. control O
Installation
Electric heater(operation) X
High ceiling operation -
Hot start O
Reliability Self diagnosis O
Soft dry operation O
Auto changeover O(Heat recovery)
Auto cleaning X
Auto operation(artificial intelligence) O(Heat pump or Cooling only)
Auto restart operation O
Child lock O
Convenience Forced operation -
Group control O
Sleep mode O
Timer(on/off) O
Timer(weekly) O
Two thermistor control O
Wide wired remote controller PQRCVSL0/PQRCVSL0QW
Deluxe wired remote controller PQRCUDS0(B/S)
Individual Simple wired remote controller PQRCVCL0Q(W)
control Wired remote controller(for hotel use) PQRCHCA0Q(W)
Wireless LCD remote control PQWRH(C)Q0FDB
Zone control -
CTIE -
Special Electro thermostat -
function kit Remote temperature sensor PQRSTA0
Group control wire PZCWRCG3
Dry contact PQDSA(1)/PQDSB(1)/PQDSBC/PQDSBNGCM1/PQDSBCGCD0

O : Applied X : Not applied – : No relation


Option : Model name & price are different according to options, and assembled in factory with main unit.
Accessory : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate
package.

Ceiling Concealed Duct_Built in (Low Static) _ 1


2. Specification

Type Ceiling Concealed Duct (Built-in (Low Static))


Accessory PBSGB30/PBSC30 PBSGB30/PBSC30 PBSGB30/PBSC30
Model Unit ARNU07GB3G2 ARNU09GB3G2 ARNU12GB3G2
kW 2.2 2.8 3.6
Cooling Capacity kcal/h 1,900 2,400 3,100
Btu/h 7,500 9,600 12,300
kW 2.5 3.2 4.0
Heating Capacity kcal/h 2,200 2,800 3,400
Btu/h 8,500 10,900 13,600
Casing Galvanized Steel Plate Galvanized Steel Plate Galvanized Steel Plate
mm 820 x 190 x 575 820 x 190 x 575 820 x 190 x 575
Dimensions(WxHxD) Body
inch 32-9/32 x 7-15/32 x 22-5/8 32-9/32 x 7-15/32 x 22-5/8 32-9/32 x 7-15/32 x 22-5/8
Coil Rows x Columns x FPI 2 x 11 x 21 2 x 11 x 21 2 x 11 x 21
Face Area m2 0.16 0.16 0.16
Type Sirocco Fan Sirocco Fan Sirocco Fan
Motor Output x Number W 30 30 30
Running Current A 0.15 0.15 0.15
Indoor Units

Air Flow Rate(H / M / L) CMM 8.0 / 6.5 / 5.5 9.0 / 7.0 / 6.0 10.0 / 8.0 / 6.5
(High Mode-factor set) cfm 283 / 229 / 194 318 / 247 / 212 353 / 283 / 229
Fan External Static Pressure mmAq(Pa) 2(20) 2(20) 2(20)
Air Flow Rate(H / M / L) CMM 8.0 / 6.5 / 5.5 9.0 / 7.0 / 6.0 10.0 / 8.0 / 6.5
(Standard Mode) cfm 283 / 229 / 194 318 / 247 / 212 353 / 283 / 229
External Static Pressure mmAq(Pa) 0(0) 0(0) 0(0)
Drive Direct Direct Direct
Motor type BLDC BLDC BLDC
Temperature Control Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating
Sound Absorbing Thermal Insulation Material Foamed polystrene Foamed polystrene Foamed polystrene
Air Filter - - -
Safety Device Fuse, Thermal Fuse for Fan Motor Fuse, Thermal Fuse for Fan Motor Fuse, Thermal Fuse for Fan Motor
Liquid Side mm(inch) Ø6.35(1/4) Ø6.35(1/4) Ø6.35(1/4)
Pipe Connections Gas Side mm(inch) Ø12.7(1/2) Ø12.7(1/2) Ø12.7(1/2)
Drain Pipe(Internal Dia.) mm(inch) 25.4(1) 25.4(1) 25.4(1)
Net Weight kg(lbs) 21(46.3) 21(46.3) 21(46.3)
Noise Level(Sound Press, 1m, H / M / L) dB(A) 33 / 32 / 29 34 / 33 / 32 35 / 34 / 33
Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50
1, 220, 60 1, 220, 60 1, 220, 60
Refrigerant Control EEV EEV EEV
Power cable mm2 CV1.5 x 3C CV1.5 x 3C CV1.5 x 3C
Transmission cable mm2 CVV-SB 1.0~1.5 x 2C CVV-SB 1.0~1.5 x 2C CVV-SB 1.0~1.5 x 2C
Notes:-
Conversion Formula
1. Capacities are based on the following conditions:
Cooling • Indoor temp. 27°C[80.6°F]DB/ 19°C[66.2°F]WB kcal/h= kW x 860
• Outdoor temp. 35°C[95°F]DB/ 24°C[75.2°F]WB Btu/h = kW x 3412
• Interconnecting Piping Length 7.5m cfm = m3/min x 35.3
• Level Difference of Zero l/s = CMM x 1000/60
Heating • Indoor temp. 20°C[68°F]DB/ 15°C[59°F]WB
• Outdoor temp. 7°C[44.6°F]DB/ 6°C[42.8°F]WB
• Interconnecting Piping Length 7.5m
• Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without notification
4. EEV: Electronic Expansion Valve
5. To be added for more available Models
6. Anechoic chamber conversion value is measured at 1.5 m downward from unit centre.
The values depends on the ambient conditions and values are normally higher in actual operation.

2 _ Ceiling Concealed Duct_Built in (Low Static)


2. Specification

Type Ceiling Concealed Duct (Built-in (Low Static))


Accessory PBSGB30/PBSC30 PBSGB40/PBSC40 PBSGB40/PBSC40
Model Unit ARNU15GB3G2 ARNU18GB4G2 ARNU24GB4G2
kW 4.5 5.6 7.1
Cooling Capacity kcal/h 3,900 4,800 6,100
Btu/h 15,400 19,100 24,200
kW 5.0 6.3 8.0
Heating Capacity kcal/h 4,300 5,400 6,900
Btu/h 17,100 21,500 27,300
Casing Galvanized Steel Plate Galvanized Steel Plate Galvanized Steel Plate
Dimensions(WxHxD) Body mm 820 x 190 x 575 1,100 x 190 x 575 1,100 x 190 x 575
inch 32-9/32 x 7-15/32 x 22-5/8 43-5/16 x 7-15/32 x 22-5/8 43-5/16 x 7-15/32 x 22-5/8
Coil Rows x Columns x FPI 2 x 11 x 21 3 x 10 x 18 3 x 10 x 18
Face Area m2 0.16 0.23 0.23
Type Sirocco Fan Sirocco Fan Sirocco Fan
Motor Output x Number W 30 80 80
Running Current A 0.15 0.38 0.38

Indoor Units
Air Flow Rate(H / M / L) CMM 11.0 / 10.0 / 8.0 14.0 / 12.0 / 10.0 17.0 / 15.0 / 10.0
(High Mode-factor set) cfm 388 / 353 / 283 494 / 424 / 353 600 / 530 / 353
Fan External Static Pressure mmAq(Pa) 2(20) 2(20) 2(20)
Air Flow Rate(H / M / L) CMM 11.0 / 10.0 / 8.0 14.0 / 12.0 / 10.0 17.0 / 15.0 / 10.0
(Standard Mode) cfm 388 / 353 / 283 494 / 424 / 353 600 / 530 / 353
External Static Pressure mmAq(Pa) 0(0) 0(0) 0(0)
Drive Direct Direct Direct
Motor type BLDC BLDC BLDC
Temperature Control Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating
Sound Absorbing Thermal Insulation Material Foamed polystrene Foamed polystrene Foamed polystrene
Air Filter - - -
Safety Device Fuse, Thermal Fuse for Fan Motor Fuse, Thermal Fuse for Fan Motor Fuse, Thermal Fuse for Fan Motor
Liquid Side mm(inch) Ø6.35(1/4) Ø6.35(1/4) Ø9.52(3/8)
Pipe Connections Gas Side mm(inch) Ø12.7(1/2) Ø12.7(1/2) Ø15.88(5/8)
Drain Pipe(Internal Dia.) mm(inch) 25.4(1) 25.4(1) 25.4(1)
Net Weight kg(lbs) 21(46.3) 26(57.3) 26(57.3)
Noise Level(Sound Press, 1m, H / M / L) dB(A) 41 / 40 / 37 43 / 40 / 37 46 / 43 / 37
Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50
1, 220, 60 1, 220, 60 1, 220, 60
Refrigerant Control EEV EEV EEV
Power cable mm2 CV1.5 x 3C CV1.5 x 3C CV1.5 x 3C
Transmission cable mm2 CVV-SB 1.0~1.5 x 2C CVV-SB 1.0~1.5 x 2C CVV-SB 1.0~1.5 x 2C

Notes:-
Conversion Formula
1. Capacities are based on the following conditions:
Cooling • Indoor temp. 27°C[80.6°F]DB/ 19°C[66.2°F]WB kcal/h= kW x 860
• Outdoor temp. 35°C[95°F]DB/ 24°C[75.2°F]WB Btu/h = kW x 3412
• Interconnecting Piping Length 7.5m cfm = m3/min x 35.3
• Level Difference of Zero l/s = CMM x 1000/60
Heating • Indoor temp. 20°C[68°F]DB/ 15°C[59°F]WB
• Outdoor temp. 7°C[44.6°F]DB/ 6°C[42.8°F]WB
• Interconnecting Piping Length 7.5m
• Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without notification
4. EEV: Electronic Expansion Valve
5. To be added for more available Models
6. Anechoic chamber conversion value is measured at 1.5 m downward from unit centre.
The values depends on the ambient conditions and values are normally higher in actual operation.

Ceiling Concealed Duct_Built in (Low Static) _ 3


Indoor Units

Ceiling Concealed Duct (Built-in (Low Static))


B3/B4
ARNU07GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y)
ARNU09GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y)
With Suction Grille ARNU12GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y)
With Suction Grille & Suction Canvas
ARNU15GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y)
ARNU18GB4G2+PBSGB40(Acc'y), PBSC40(Acc'y)
ARNU24GB4G2+PBSGB40(Acc'y), PBSC40(Acc'y)
3. Dimensions

190
6
65 60

216

277
2

24

575
383
388
618
1

3
5

A
With Suction Grille 4

4 _ Ceiling Concealed Duct_Built in (Low Static)


Btu/h A

190
(unit : mm)

250
7,9,12,15k 820
B 18,24k 1100 Number Name Descripition
D Unit size(7k,9k,12k,15k,18k):ø6.35
With Suction Grille & Suction Canvas 1 Liquid pipe connection Unit size(24k):ø9.52
B C D
PBSGB30 910 359 56
Unit size(7k,9k,12k,15k,18k):ø12.7
2 Gas pipe connection Unit size(24k):ø15.88
PBSGB40 1188 359 56

190
3 Drain pipe connection
E F G 4 Power supply connection
PBSC30 821 274 42~250

500(Max)
PBSC40 1100 274 42~250
5 Air suction
6 Air discharge

G
Note
E F 1. Unit should be installed in compliance with the installation manual
in the product box.
2. Unit shall be grounded in accordance with the local regulations or
applicable national codes.

76, Seongsan-dong, Changwon City, Gyeongnam,


641-713, Korea CHASSIS CODE: B3/B4
4. Piping Diagrams

:Cooling
Heat Exchanger EEV :Heating
Filter

Th3 Th2
Sirocco Fan Filter

Th1 lndoor unit

Indoor Units
Refrigerant pipe connection port diameter

[Unit: mm(inch)]

MODEL GAS LIQUID

ARNU07GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y) Ø12.7(1/2) Ø6.35(1/4)

ARNU09GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y) Ø12.7(1/2) Ø6.35(1/4)

ARNU12GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y) Ø12.7(1/2) Ø6.35(1/4)

ARNU15GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y) Ø12.7(1/2) Ø6.35(1/4)

ARNU18GB4G2+PBSGB40(Acc'y), PBSC40(Acc'y) Ø12.7(1/2) Ø6.35(1/4)

ARNU24GB4G2+PBSGB40(Acc'y), PBSC40(Acc'y) Ø15.88(5/8) Ø9.52(3/8)

LOC. Description
Th1 Room thermistor
Th2 Pipe in thermistor
Th3 Pipe out thermistor

Ceiling Concealed Duct_Built in (Low Static) _ 5


5. Wiring Diagrams
B3/B4 Chassis
Indoor Units

CONNECTOR NUMBER SPEC. DESCRIPTION


CN-MOTOR1 Fan motor output Motor output of BLDC
CN-MOTOR2 Fan motor output Motor output of BLDC
CN-PIPE/OUT Discharge pipe sensor Pipe out thermistor
CN-PIPE/IN Suction pipe sensor Pipe in thermistor
CN-ROOM Room sensor Room thermistor
CN-REMO Remote controller Remote control line
CN-FLOAT Float switch input Float switch sensing
CN-EEV EEV output EEV control output
CN-D/PUMP Drain pump output AC output for drain pump
CN-OPTION Option PWB. Communication between main and option
CN-COM Communication Communication between indoor and outdoor
CN-D/PUMP Drain pump output AC output for drain pump
CN-POWER AC power supply AC power line input for indoor controller
CN-ZONE Zone Controller Zone control line
CN-DISPLAY RF Remote controller RF remote control line
CN-CC Dry contact Dry contact line
Dip Switch Setting Off On Remarks
SW3 GROUP Master Slave Group Control setting using Wired Remote Controller
Old Dry Contact Mode Setting
1. Variable : Auto/Manual Mode can be chosen by Wide wired
SW4 DRY CONTACT Variable Auto remote controller or Wireless remote controller
(When shipped from Factory ’ Manual Mode)
2. Auto : For Dry Contact, it is always Auto mode.
1. Duct model
-. OFF : Default(not operate continuosly )
-. ON : Fan operate continuosly
SW5 EXTRA 1 Off On 2. Cassette Model : No Function
3. Ceiling Suspended Model
-. OFF : Ceiling(default)
-. ON : Floor

CAUTION
For Multi V Model, Dip Switch 1,2,6,7,8 must be set OFF
That dip switch is used for the other model.

6 _ Ceiling Concealed Duct_Built in (Low Static)


6. Capacity Tables
6.1 Cooling Capacity
Cooling capacity

Indoor air temp. (DB/WB, °C)


Capacity Outdoor 20 23 26 27 28 30 32
Index air temp. 14 16 18 19 20 22 24
(DB, °C) TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.6 1.7 2.9 1.7
12 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.6 1.7 2.9 1.7
14 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.6 1.7 2.8 1.7
16 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.6 1.7 2.8 1.6
18 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.6 1.7 2.7 1.6
20 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.6 1.7 2.7 1.6
21 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.6 1.7 2.7 1.6
23 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.6 1.7 2.6 1.6
2.2 25 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.6 1.7 2.6 1.5
27 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.5 1.7 2.6 1.5

Indoor Units
29 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.5 1.6 2.5 1.5
31 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.5 1.6 2.5 1.5
33 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.4 1.6 2.5 1.5
35 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.7 2.4 1.6 2.4 1.4
37 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.3 1.6 2.3 1.5 2.4 1.4
39 1.5 1.3 1.8 1.5 2.1 1.6 2.2 1.6 2.2 1.6 2.3 1.5 2.3 1.4
10 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.7 2.2
12 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.6 2.1
14 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.6 2.1
16 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.5 2.1
18 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.5 2.1
20 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.4 2.0
21 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.4 2.0
23 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.4 2.0
2.8 25 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.3 2.2 3.3 2.0
27 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.2 2.1 3.3 1.9
29 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.2 2.1 3.2 1.9
31 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.1 2.1 3.2 1.9
33 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.1 2.0 3.1 1.9
35 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.0 2.0 3.1 1.8
37 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 2.9 2.1 3.0 1.9 3.0 1.8
39 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 2.9 2.0 2.9 1.9 3.0 1.8
10 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.7 2.8
12 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.7 2.8
14 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.6 2.7
16 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.6 2.7
18 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.5 2.7
20 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.4 2.6
21 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.4 2.6
23 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.3 2.6
3.6 25 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.2 2.8 4.3 2.5
27 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.1 2.7 4.2 2.5
29 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.1 2.7 4.2 2.5
31 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.0 2.6 4.1 2.4
33 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.0 2.6 4.0 2.4
35 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 3.9 2.6 4.0 2.3
37 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.7 2.6 3.8 2.5 3.9 2.3
39 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.6 3.7 2.6 3.7 2.5 3.8 2.3

Ceiling Concealed Duct_Built in (Low Static) _ 7


6. Capacity Tables

Cooling capacity

Indoor air temp. (DB/WB, °C)


Capacity Outdoor 20 23 26 27 28 30 32
Index air temp. 14 16 18 19 20 22 24
(DB, °C) TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10 3.0 2.6 3.6 2.9 4.2 3.1 4.5 3.2 4.8 3.3 5.4 3.5 5.9 3.4
12 3.0 2.6 3.6 2.9 4.2 3.1 4.5 3.2 4.8 3.3 5.4 3.5 5.8 3.4
14 3.0 2.6 3.6 2.9 4.2 3.1 4.5 3.2 4.8 3.3 5.4 3.5 5.8 3.3
16 3.0 2.6 3.6 2.9 4.2 3.1 4.5 3.2 4.8 3.3 5.4 3.5 5.7 3.3
18 3.0 2.6 3.6 2.9 4.2 3.1 4.5 3.2 4.8 3.3 5.4 3.5 5.6 3.3
20 3.0 2.6 3.6 2.9 4.2 3.1 4.5 3.2 4.8 3.3 5.4 3.5 5.5 3.2
21 3.0 2.6 3.6 2.9 4.2 3.1 4.5 3.2 4.8 3.3 5.4 3.5 5.5 3.2
23 3.0 2.6 3.6 2.9 4.2 3.1 4.5 3.2 4.8 3.3 5.4 3.5 5.4 3.1
4.5 25 3.0 2.6 3.6 2.9 4.2 3.1 4.5 3.2 4.8 3.3 5.3 3.4 5.3 3.1
27 3.0 2.6 3.6 2.9 4.2 3.1 4.5 3.2 4.8 3.3 5.2 3.3 5.3 3.1
29 3.0 2.6 3.6 2.9 4.2 3.1 4.5 3.2 4.8 3.3 5.1 3.3 5.2 3.0
Indoor Units

31 3.0 2.6 3.6 2.9 4.2 3.1 4.5 3.2 4.8 3.3 5.1 3.2 5.1 2.9
33 3.0 2.6 3.6 2.9 4.2 3.1 4.5 3.2 4.8 3.3 4.9 3.2 5.0 2.9
35 3.0 2.6 3.6 2.9 4.2 3.1 4.5 3.2 4.8 3.3 4.9 3.1 4.9 2.9
37 3.0 2.6 3.6 2.9 4.2 3.1 4.5 3.2 4.7 3.2 4.8 3.1 4.9 2.8
39 3.0 2.6 3.6 2.9 4.2 3.1 4.5 3.2 4.6 3.1 4.7 3.0 4.8 2.8
10 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 6.0 4.1 6.7 4.3 7.4 4.2
12 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 6.0 4.1 6.7 4.3 7.3 4.2
14 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 6.0 4.1 6.7 4.3 7.2 4.1
16 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 6.0 4.1 6.7 4.3 7.1 4.1
18 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 6.0 4.1 6.7 4.3 7.0 4.0
20 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 6.0 4.1 6.7 4.3 6.9 4.0
21 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 6.0 4.1 6.7 4.3 6.8 3.9
23 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 6.0 4.1 6.7 4.3 6.7 3.9
5.6 25 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 6.0 4.1 6.6 4.2 6.6 3.8
27 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 6.0 4.1 6.4 4.1 6.6 3.8
29 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 6.0 4.1 6.4 4.1 6.5 3.7
31 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 6.0 4.1 6.3 4.0 6.4 3.7
33 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 6.0 4.1 6.2 3.9 6.3 3.6
35 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 6.0 4.1 6.0 3.9 6.2 3.5
37 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 5.8 4.0 5.9 3.8 6.1 3.5
39 3.8 3.3 4.5 3.6 5.2 3.9 5.6 4.0 5.7 3.9 5.8 3.7 6.0 3.4
10 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.5 5.4 9.3 5.4
12 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.5 5.4 9.2 5.3
14 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.5 5.4 9.1 5.2
16 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.5 5.4 9.0 5.2
18 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.5 5.4 8.8 5.1
20 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.5 5.4 8.7 5.0
21 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.5 5.4 8.7 5.0
23 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.5 5.4 8.5 4.9
7.1 25 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.4 5.4 8.4 4.8
27 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.2 5.2 8.3 4.8
29 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.1 5.2 8.2 4.7
31 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.0 5.1 8.1 4.6
33 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 7.8 5.0 7.9 4.6
35 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 7.7 4.9 7.8 4.5
37 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.4 5.1 7.5 4.8 7.7 4.4
39 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.2 5.0 7.4 4.7 7.6 4.4
Notes:
TC: Total Capacity(kW), SHC: Sensible Heat Capacity(kW) 2. Refer to Capacity Correction Factor in the outdoor unit PDB for
1. Capacity tables show the representative value of conditions the actual performance data of each indoor unit and outdoor unit
which may occur. combination.

8 _ Ceiling Concealed Duct_Built in (Low Static)


6. Capacity Tables
6.2 Heating Capacity Heating capacity

Outdoor air Indoor air temp. (DB, °C)


Capacity temp. 16 18 20 21 22 24
Index TC TC TC TC TC TC
DB(°C) WB(°C)
kW kW kW kW kW kW
-24.8 -25.0 1.4 1.4 1.4 1.4 1.4 1.4
-21.8 -22.0 1.7 1.7 1.7 1.7 1.7 1.7
-19.8 -20.0 1.8 1.8 1.8 1.8 1.8 1.8
-18.8 -19.0 1.9 1.9 1.9 1.9 1.9 1.9
-16.7 -17.0 2.0 2.0 2.0 2.0 2.0 2.0
-14.7 -15.0 2.1 2.1 2.1 2.1 2.1 2.0
-12.6 -13.0 2.2 2.2 2.2 2.2 2.1 2.1
-10.5 -11.0 2.3 2.3 2.2 2.2 2.2 2.2
-9.5 -10.0 2.3 2.3 2.3 2.3 2.3 2.2
-8.5 -9.1 2.3 2.3 2.3 2.3 2.3 2.2
-7.0 -7.6 2.4 2.4 2.4 2.4 2.3 2.2
2.2 -5.0 -5.6 2.5 2.5 2.5 2.4 2.3 2.2
-3.0 -3.7 2.6 2.6 2.5 2.4 2.3 2.2
0.0 -0.7 2.7 2.6 2.5 2.4 2.3 2.2
3.0 2.2 2.7 2.7 2.5 2.4 2.3 2.2

Indoor Units
5.0 4.1 2.8 2.7 2.5 2.4 2.3 2.2
7.0 6.0 2.8 2.7 2.5 2.4 2.3 2.2
9.0 7.9 2.8 2.7 2.5 2.4 2.3 2.2
11.0 9.8 2.8 2.7 2.5 2.4 2.3 2.2
13.0 11.8 2.8 2.7 2.5 2.4 2.3 2.2
15.0 13.7 2.8 2.7 2.5 2.4 2.3 2.2
-24.8 -25.0 1.9 1.9 1.8 1.8 1.8 1.8
-21.8 -22.0 2.2 2.2 2.2 2.2 2.2 2.2
-19.8 -20.0 2.4 2.4 2.3 2.3 2.3 2.3
-18.8 -19.0 2.4 2.4 2.4 2.4 2.4 2.4
-16.7 -17.0 2.5 2.5 2.5 2.5 2.5 2.5
-14.7 -15.0 2.7 2.7 2.6 2.6 2.6 2.6
-12.6 -13.0 2.8 2.8 2.8 2.8 2.7 2.7
-10.5 -11.0 2.9 2.9 2.9 2.9 2.9 2.8
-9.5 -10.0 3.0 3.0 2.9 2.9 2.9 2.8
-8.5 -9.1 3.0 3.0 3.0 3.0 3.0 2.8
2.8 -7.0 -7.6 3.1 3.1 3.1 3.1 3.0 2.8
-5.0 -5.6 3.2 3.2 3.2 3.1 3.0 2.8
-3.0 -3.7 3.4 3.3 3.2 3.1 3.0 2.8
0.0 -0.7 3.4 3.3 3.2 3.1 3.0 2.8
3.0 2.2 3.5 3.4 3.2 3.1 3.0 2.8
5.0 4.1 3.6 3.4 3.2 3.1 3.0 2.8
7.0 6.0 3.6 3.4 3.2 3.1 3.0 2.8
9.0 7.9 3.6 3.4 3.2 3.1 3.0 2.8
11.0 9.8 3.6 3.4 3.2 3.1 3.0 2.8
13.0 11.8 3.6 3.4 3.2 3.1 3.0 2.8
15.0 13.7 3.6 3.4 3.2 3.1 3.0 2.8
-24.8 -25.0 2.3 2.3 2.3 2.3 2.3 2.3
-21.8 -22.0 2.8 2.8 2.8 2.8 2.8 2.8
-19.8 -20.0 2.9 2.9 2.9 2.9 2.9 2.9
-18.8 -19.0 3.0 3.0 3.0 3.0 3.0 3.0
-16.7 -17.0 3.1 3.1 3.1 3.1 3.1 3.1
-14.7 -15.0 3.3 3.3 3.3 3.3 3.3 3.3
-12.6 -13.0 3.5 3.4 3.4 3.4 3.4 3.4
-10.5 -11.0 3.6 3.6 3.6 3.6 3.6 3.5
-9.5 -10.0 3.7 3.7 3.7 3.7 3.7 3.5
-8.5 -9.1 3.8 3.8 3.7 3.7 3.7 3.5
-7.0 -7.6 3.9 3.9 3.9 3.8 3.7 3.5
3.6 -5.0 -5.6 4.0 4.0 4.0 3.9 3.7 3.5
-3.0 -3.7 4.2 4.1 4.0 3.9 3.7 3.5
0.0 -0.7 4.3 4.1 4.0 3.9 3.7 3.5
3.0 2.2 4.4 4.3 4.0 3.9 3.7 3.5
5.0 4.1 4.5 4.3 4.0 3.9 3.7 3.5
7.0 6.0 4.5 4.3 4.0 3.9 3.7 3.5
9.0 7.9 4.5 4.3 4.0 3.9 3.7 3.5
11.0 9.8 4.5 4.3 4.0 3.9 3.7 3.5
13.0 11.8 4.5 4.3 4.0 3.9 3.7 3.5
15.0 13.7 4.5 4.3 4.0 3.9 3.7 3.5

Ceiling Concealed Duct_Built in (Low Static) _ 9


6. Capacity Tables
Heating capacity

Outdoor air Indoor air temp. (DB, °C)


Capacity temp. 16 18 20 21 22 24
Index TC TC TC TC TC TC
DB(°C) WB(°C)
kW kW kW kW kW kW
-24.8 -25.0 2.9 2.9 2.9 2.9 2.9 2.9
-21.8 -22.0 3.5 3.5 3.5 3.5 3.5 3.5
-19.8 -20.0 3.7 3.7 3.7 3.7 3.7 3.6
-18.8 -19.0 3.8 3.7 3.7 3.7 3.7 3.7
-16.7 -17.0 3.9 3.9 3.9 3.9 3.9 3.9
-14.7 -15.0 4.1 4.1 4.1 4.1 4.1 4.1
-12.6 -13.0 4.3 4.3 4.3 4.3 4.3 4.3
-10.5 -11.0 4.5 4.5 4.5 4.5 4.5 4.4
-9.5 -10.0 4.6 4.6 4.6 4.6 4.6 4.4
-8.5 -9.1 4.7 4.7 4.7 4.7 4.7 4.4
-7.0 -7.6 4.8 4.8 4.8 4.8 4.7 4.4
4.5 -5.0 -5.6 5.0 5.0 5.0 4.8 4.7 4.4
-3.0 -3.7 5.3 5.1 5.0 4.8 4.7 4.4
0.0 -0.7 5.3 5.2 5.0 4.8 4.7 4.4
3.0 2.2 5.5 5.3 5.0 4.8 4.7 4.4
Indoor Units

5.0 4.1 5.6 5.3 5.0 4.8 4.7 4.4


7.0 6.0 5.6 5.3 5.0 4.8 4.7 4.4
9.0 7.9 5.6 5.3 5.0 4.8 4.7 4.4
11.0 9.8 5.6 5.3 5.0 4.8 4.7 4.4
13.0 11.8 5.6 5.3 5.0 4.8 4.7 4.4
15.0 13.7 5.6 5.3 5.0 4.8 4.7 4.4
-24.8 -25.0 3.6 3.6 3.6 3.6 3.6 3.6
-21.8 -22.0 4.4 4.4 4.4 4.4 4.4 4.4
-19.8 -20.0 4.6 4.6 4.6 4.6 4.6 4.6
-18.8 -19.0 4.8 4.7 4.7 4.7 4.7 4.7
-16.7 -17.0 5.0 5.0 5.0 4.9 4.9 4.9
-14.7 -15.0 5.2 5.2 5.2 5.2 5.2 5.2
-12.6 -13.0 5.5 5.4 5.4 5.4 5.4 5.4
-10.5 -11.0 5.7 5.7 5.7 5.7 5.7 5.5
-9.5 -10.0 5.8 5.8 5.8 5.8 5.8 5.5
-8.5 -9.1 5.9 5.9 5.9 5.9 5.9 5.5
5.6 -7.0 -7.6 6.1 6.1 6.1 6.0 5.9 5.5
-5.0 -5.6 6.3 6.3 6.3 6.1 5.9 5.5
-3.0 -3.7 6.6 6.5 6.3 6.1 5.9 5.5
0.0 -0.7 6.7 6.5 6.3 6.1 5.9 5.5
3.0 2.2 6.9 6.7 6.3 6.1 5.9 5.5
5.0 4.1 7.0 6.7 6.3 6.1 5.9 5.5
7.0 6.0 7.1 6.7 6.3 6.1 5.9 5.5
9.0 7.9 7.1 6.7 6.3 6.1 5.9 5.5
11.0 9.8 7.1 6.7 6.3 6.1 5.9 5.5
13.0 11.8 7.1 6.7 6.3 6.1 5.9 5.5
15.0 13.7 7.1 6.7 6.3 6.1 5.9 5.5
-24.8 -25.0 4.6 4.6 4.6 4.6 4.6 4.6
-21.8 -22.0 5.6 5.6 5.6 5.6 5.6 5.5
-19.8 -20.0 5.9 5.9 5.9 5.9 5.9 5.8
-18.8 -19.0 6.0 6.0 6.0 6.0 6.0 6.0
-16.7 -17.0 6.3 6.3 6.3 6.3 6.3 6.3
-14.7 -15.0 6.6 6.6 6.6 6.6 6.6 6.6
-12.6 -13.0 6.9 6.9 6.9 6.9 6.9 6.9
-10.5 -11.0 7.2 7.2 7.2 7.2 7.2 7.0
-9.5 -10.0 7.4 7.4 7.3 7.3 7.3 7.0
-8.5 -9.1 7.5 7.5 7.5 7.5 7.5 7.0
-7.0 -7.6 7.7 7.7 7.7 7.7 7.5 7.0
7.1 -5.0 -5.6 8.0 8.0 8.0 7.7 7.5 7.0
-3.0 -3.7 8.4 8.2 8.0 7.7 7.5 7.0
0.0 -0.7 8.6 8.3 8.0 7.7 7.5 7.0
3.0 2.2 8.8 8.5 8.0 7.7 7.5 7.0
5.0 4.1 8.9 8.5 8.0 7.7 7.5 7.0
7.0 6.0 9.0 8.5 8.0 7.7 7.5 7.0
9.0 7.9 9.0 8.5 8.0 7.7 7.5 7.0
11.0 9.8 9.0 8.5 8.0 7.7 7.5 7.0
13.0 11.8 9.0 8.5 8.0 7.7 7.5 7.0
15.0 13.7 9.0 8.5 8.0 7.7 7.5 7.0
Notes:
TC: Total Capacity(kW) 3. In accordance with operation limits of outdoor unit, applicable range of
1. Capacity tables show the representative value of conditions which may occur. capacity tables is different.
2. is shown as reference. When selecting the outdoor units, avoid the 4. Refer to Capacity Correction Factor in the outdoor unit PDB for the actual
outdoor air temperature range shown by . performance data of each indoor unit and outdoor unit combination.

10 _ Ceiling Concealed Duct_Built in (Low Static)


7. External Static Pressure (E.S.P) & Air Flow
ARNU07GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y)
ARNU09GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y)
ARNU12GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y)
ARNU15GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y) (Unit: CMM)

Static Pressure(mmAq(Pa))
Setting Value
0(0) 1(10) 2(20) 3(29) 4(39)
60 6.29 3.03 0.93 - -
65 6.61 4.84 1.52 - -
70 7.69 5.64 2.18 0.79 -
75 8.19 6.28 2.81 0.85 -
80 8.91 7.43 4.96 1.58 -
85 9.51 8.14 5.91 2.75 0.95

Indoor Units
90 10.21 8.76 6.79 3.41 1.36
95 10.83 9.62 8.11 5.48 2.61
100 11.31 10.55 9.02 6.12 3.31
105 11.84 11.19 9.99 8.28 5.32
110 12.68 11.88 10.38 9.16 6.92
115 13.19 12.22 11.55 10.21 8.23

ARNU18GB4G2+PBSGB40(Acc'y), PBSC40(Acc'y)
ARNU24GB4G2+PBSGB40(Acc'y), PBSC40(Acc'y) (Unit: CMM)

Static Pressure(mmAq(Pa))
Setting Value
0(0) 1(10) 2(20) 3(29) 4(39)
75 10.32 7.68 3.55 - -
80 11.06 8.77 4.71 1.38 -
85 11.84 10.02 6.95 2.16 -
90 12.73 10.74 8.26 4.73 1.25
95 13.47 12.13 9.93 6.74 2.73
100 14.16 13.25 10.51 8.41 3.65
105 15.29 14.11 12.31 9.83 6.21
110 16.09 14.77 13.49 10.39 8.32
115 16.91 15.88 14.48 12.77 9.92
120 17.81 16.88 15.15 13.98 10.85
125 18.55 17.84 16.12 15.13 12.97
130 19.01 18.55 17.33 16.28 14.59

Note :
1. The above table shows the correlation between the air rates and E.S.P.
2. E.S.P. is given after subtracting coil losses motor step factory installed
3. E.S.P. can be higher than the maximum given in the table, but the unit faces the problem of freezing the coil.

Ceiling Concealed Duct_Built in (Low Static) _ 11


7. External Static Pressure (E.S.P) & Air Flow
ARNU07GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y)
ARNU09GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y)
ARNU12GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y)
ARNU15GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y)
Standard Lower Limit of External Upper Limit of External
Capacity Mode Set value ESP(mmAq(Pa)) CMM Static Pressure(mmAq(Pa)) Static Pressure(mmAq(Pa))

High HI 94 8
Mid 88 2(20) 6.5 - 4(39)
(factory set) 5.5
7k Low 83
HI 74 8
Standard Mid 62 0(0) 6.5 - 4(39)
Low 56 5.5
High HI 99 9
Mid 89 2(20) 7 - 4(39)
(factory set) Low 85 6
9k
HI 82 9
Standard Mid 66 0(0) 7 - 4(39)
Indoor Units

Low 58 6
High HI 105 10
Mid 94 2(20) 8 - 4(39)
(factory set) Low 88 6.5
12k HI 90 10
Standard Mid 74 0(0) 8 - 4(39)
Low 62 6.5
HI 110 11
High Mid 105 2(20) 10 - 4(39)
(factory set) Low 94 8
15k HI 96 11
Standard Mid 90 0(0) 10 - 4(39))
Low 74 8

ARNU18GB4G2+PBSGB40(Acc'y), PBSC40(Acc'y)
ARNU24GB4G2+PBSGB40(Acc'y), PBSC40(Acc'y)
Standard Lower Limit of External Upper Limit of External
Capacity Mode Set value ESP(mmAq(Pa)) CMM Static Pressure(mmAq(Pa)) Static Pressure(mmAq(Pa))

High HI 115 14
Mid 103 2(20) 12 - 4(39)
(factory set)
18k Low 93 10
HI 100 14
Standard Mid 86 0(0) 12 - 4(39)
Low 74 10
High HI 128 17
Mid 118 2(20) 15 - 4(39)
(factory set) Low 93 10
24k
HI 116 17
Standard Mid 104 0(0) 15 - 4(39)
Low 74 10

12 _ Ceiling Concealed Duct_Built in (Low Static)


8. Electric Characteristics
Units Power Supply IFM Input(W)
Model Type Hz Volts Voltage Range MCA MFA kW FLA Cooling Heating
ARNU07GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y) B3 0.22 15 0.028 0.17 30 30
ARNU09GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y) B3 0.22 15 0.028 0.17 30 30
ARNU12GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y) B3 Max:264 0.22 15 0.028 0.17 30 30
50 220-240
ARNU15GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y) B3 Min:198 0.22 15 0.028 0.17 30 30
ARNU18GB4G2+PBSGB40(Acc'y), PBSC40(Acc'y) B4 0.55 15 0.076 0.44 80 80
ARNU24GB4G2+PBSGB40(Acc'y), PBSC40(Acc'y) B4 0.55 15 0.076 0.44 80 80
ARNU07GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y) B3 0.22 15 0.028 0.17 30 30
ARNU09GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y) B3 0.22 15 0.028 0.17 30 30
ARNU12GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y) B3 Max:242 0.22 15 0.028 0.17 30 30
60 220
ARNU15GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y) B3 Min:198 0.22 15 0.028 0.17 30 30
ARNU18GB4G2+PBSGB40(Acc'y), PBSC40(Acc'y) B4 0.55 15 0.076 0.44 80 80
ARNU24GB4G2+PBSGB40(Acc'y), PBSC40(Acc'y) B4 0.55 15 0.076 0.44 80 80

Indoor Units
Symbols:
MCA : Min, Circuit Amps(A)
MFA : Max. Fuse Amps(see note 5)
kW : Fan Motor Rated Output(kW)
FLA : Full Load Amps(A)
IFA : Indoor Fan Motor
Note :
1. Voltage range
Units are suitable for use on electrical systems where voltage supplied to unit terminals is not below or above
listed range limits,
2. Maximum allowable voltage unbalance between phases is 2%
3. MCA/MFA
MCA=1.25 x FLA
MFA≤ 4 x FLA
(Next lower standard fuse rating. Min. 15A)
4. Select wire size based on the MCA
5. Instead of fuse, use Circuit Breaker.

Ceiling Concealed Duct_Built in (Low Static) _ 13


9. Sound Levels
Overall
Notes:
1. Sound measured at 1.5m away from the center of the unit
2. Operating condition
- Power source : 220-240V 50Hz / 220V 60Hz
Ceiling - Cooling : Indoor temperature (27°C DB, 19°C WB),
Outdoor temperature (35°C DB, 24°C WB)

1.5m
- Heating : Indoor temperature (20°C DB, 15°C WB),
2.0m
Outdoor temperature (7°C DB, 6°C WB)
3. Reference accoustic pressure 0dB = 20μPa
Microphone 4. Sound level will vary depending on a range of factors such as
the construction(acoustic absorption coefficient) of particular
❈ Measuring place : Anechoic chamber room in which the equipment in installed.

Sound Levels dB(A)


Model Name
H M L
ARNU07GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y) 33 32 29
ARNU09GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y) 34 33 32
ARNU12GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y) 35 34 33
ARNU15GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y) 41 40 37
ARNU18GB4G2+PBSGB40(Acc'y), PBSC40(Acc'y) 43 40 37
Indoor Units

ARNU24GB4G2+PBSGB40(Acc'y), PBSC40(Acc'y) 46 43 37

Sound Pressure Level


ARNU07GB3G2+ ARNU09GB3G2+ ARNU12GB3G2+
PBSGB30(Acc'y), PBSC30(Acc'y) PBSGB30(Acc'y), PBSC30(Acc'y) PBSGB30(Acc'y), PBSC30(Acc'y)
80 80 80

70 70
Octave Band Sound Pressure Level (0dB = 20μPa)

70
Octave Band Sound Pressure Level (0dB = 20μPa)

Octave Band Sound Pressure Level (0dB = 20μPa)

NC-65 NC-65 NC-65


60 60 60
NC-60 NC-60
NC-60

NC-55 NC-55 NC-55


50 50 50
NC-50 NC-50
NC-50

NC-45 NC-45
NC-45 40
40 40
NC-40 NC-40
NC-40

NC-35 NC-35
NC-35 30
30 30
NC-30 NC-30
NC-30

20 NC-25 20 NC-25
20 NC-25
Approximate
Approximate NC-20 Approximate
NC-20 Hearing NC-20
Hearing Threshold Hearing
Threshold NC-15 Threshold
NC-15 10 NC-15
10 10
63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000
63 125 250 500 1000 2000 4000 8000
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

ARNU15GB3G2+ ARNU18GB4G2+ ARNU24GB4G2+


PBSGB30(Acc'y), PBSC30(Acc'y) PBSGB40(Acc'y), PBSC40(Acc'y) PBSGB40(Acc'y), PBSC40(Acc'y)
80 80
80

70 70
Octave Band Sound Pressure Level (0dB = 20μPa)

70
Octave Band Sound Pressure Level (0dB = 20μPa)

Octave Band Sound Pressure Level (0dB = 20μPa)

NC-65 NC-65
60 NC-65
60 60
NC-60 NC-60
NC-60

NC-55 NC-55
50 50 NC-55
50
NC-50 NC-50
NC-50

NC-45 NC-45
40 40 NC-45
40
NC-40 NC-40
NC-40

NC-35 NC-35
30 30 NC-35
30
NC-30 NC-30
NC-30

20 NC-25 20 NC-25
20 NC-25
Approximate
Approximate NC-20 Approximate
NC-20 Hearing NC-20
Hearing Hearing
Threshold NC-15
Threshold NC-15 10 Threshold NC-15
10 10
63 125 250 500 1000 2000 4000 8000
63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000
Octave Band Center Frequency (Hz)
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

14 _ Ceiling Concealed Duct_Built in (Low Static)


10. Installation
• Please read this instruction sheet completely before installing the product.
• When the power cord is damaged, replacement work shall be performed by authorized personnel only.
• Installation work must be performed in accordance with the national wiring standards by authorized personnel only.

Suction Grille

TEMP

Remote Controller

Suction Grille +
Suction Canvas

Indoor Units
TEMP

Remote Controller

Required Parts Required Tools


• Connecting cable • Level
• Pipes: Gas side • Screw driver
Liquid side • Electric drill
• Hanging Bolt • Hole core drill (ø70mm)
(W 3/8 or M10 length 650mm)
• Flaring Tools set
• Insulated drain hose
• Torque Wrenches
• Additional Drain hose
• Hexagonal Wrench (4mm, 5mm)
(Inner Dia ....................................25mm)
• Gas-leak detector
• Ownerʼs Manual
• Thermometer

Ceiling Concealed Duct_Built in (Low Static) _ 15


10. Installation
10.1 Selection of the best location Top view
Install the air conditioner in the location that satisfies the (unit:mm)
following conditions. Airflow

• The place shall easily bear a load exceeding four times Inspection hole
the indoor unitʼs weight. (600 x 600)
• The place shall be able to inspect the unit as the figure. Control box
• The place where the unit shall be leveled.
• The place shall easily connect with the outdoor unit.
600 600
• The place where the unit is not affected by an electrical
noise.
• The place where air circulation in the room will be good .

270 or more
• There should not be any heat source or steam near the
unit
Confirm the positional relationship between the unit and
suspension bolts.
Indoor Units

• Installation the ceiling opening to clean the filter or ser-


vice under the product.

(Unit : mm)
520 or more

Chassis A B
B3 600 900
B4 600 1100

• Refer to Suction grille and Suction canvas installation


manual for detail installation of Built-in duct type

B3/B4 Series : Built-in Duct type


B(Min)
A(Min)

Ceiling

Service Space

16 _ Ceiling Concealed Duct_Built in (Low Static)


10. Installation
10.2 Ceiling dimension and hanging bolt location
Installation of Unit
Install the unit above the ceiling correctly. B
A
J
CASE 1
POSITION OF SUSPENSION BOLT

D
C
• Apply a joint-canvas between the unit and duct to absorb
unnecessary vibration.

E
• Apply a filter Accessory at air return hole.

G
(Unit:mm)
Dimension

F
I
A B C D E F G H I J
Chassis
H

Indoor Units
B3 850 900 383 575 93 190 21 795 163 820 Drain Pump use
B4 1130 1180 383 575 93 190 21 1065 163 1100 Drainage hole

M10 Nut X4

M10 washer X4

CASE 2

• Install the unit leaning to a drainage hole side as a figure M10 washer X4
for easy water drainage. M10 Nut X8

POSITION OF CONSOLE BOLT

• A place where the unit will be leveled and that can support
the weight of the unit.
• A place where the unit can withstand its vibration.
• A place where service can be easily performed.

Ceiling Concealed Duct_Built in (Low Static) _ 17


10. Installation
• Select and mark the position for fixing bolts. • Insert the set anchor and washer onto the suspension
• Drill the hole for set anchor on the face of ceiling. bolts for locking the suspension bolts on the ceiling.
• Mount the suspension bolts to the set anchor firmly.
• Secure the installation plates onto the suspension
bolts (adjust level roughly) using nuts, washers and
spring washers.

Old building New building

1 Set anchor
2 Plate washer
3 Spring washer
4 Nut
CAUTION
5 Suspension
Tighten the nut and bolt to prevent unit falling. bolts
Indoor Units

10.3 Connecting Cables


Connect the wires to the terminals on the control board individually according to the outdoor unit connection.
• Ensure that the color of the wires of outdoor unit and the terminal No. are the same as those of indoor unit respectively
[Indoor Unit side] [Outdoor Unit side]
[Type 1]

Terminal Block Indoor SODU B SODU A IDU B IDU A INT B INT A


1(L) 2(N) 3 4

INDOOR POWER INPUT


[Type 2]
Terminal Block Indoor SODU IDU INTERNET DRY1 DRY2 GND 12V
1(L) 2(N) 3 4 B A - - B A - - - -

INDOOR POWER INPUT


[Type 3]
Terminal block of outdoor unit
Terminal Block Indoor Central controller Indoor unit Outdoor unit
1(L) 2(N) 3 4 12V GND DRY2 DRY1 CEN CEN IDU IDU SODU SODU

INDOOR POWER INPUT

WARNING
Make sure that the screws of the terminal are not from loose.

Clamping of cables
1) Arrange 2 power cables on the control panel.
2) First, fasten the steel clamp with a screw to the inner boss of control panel.
3) For the cooling model, fix the other side of the clamp with a screw strongly. For the heat pump model, put the
0.75mm2 cable(thinner cable) on the clamp and tighten it with a plastic clamp to the other boss of the control panel.

18 _ Ceiling Concealed Duct_Built in (Low Static)


10. Installation
10.4 Part name and functions

Air outlet Air outlet

Suction Grille
Suction Grille
Suction Canvas

• Buit-in duct type with Suction Grille • Buit-in duct type with Suction Grille and Suction
Canvas

Indoor Units
n B3/B4 Series : Built-in Duct type Control Box service

Ceiling Concealed Duct_Built in (Low Static) _ 19


10. Installation
INSULATION, OTHERS Insulate the joint and tubes completely.

THERMAL INSULATION All thermal insulation must comply with local requirement.
INDOOR UNIT
Refrigerant pipe and thermal Union for gas pipe Thermal insulator for refrigerant pipe
insulator(Local supply) (Local supply) Thermal insulator for
piping(Local supply)

Hose clip for thermal insulator


(Local supply)
Thermal insulator for refrigerant pipe Overlap with thermal
(Local supply) insulator for piping.
Hose clip for thermal insulator(Local supply)
Make sure that there is no clearance here.
Union for liquid pipe

Felt Cabinet
Rubber
Indoor Units

Insulation

No clearance

TEST AND CHECK

n After all workings are finished, check the working and operation.
• Air distribution ............... Is the air circulation good?
• Drain ............................. Is the drainage smoothly and no sweating?
• Gas leakage ................. Is the piping connection correctly?
• Wiring ........................... Is the wiring connection correctly?
• Lock-bolt ....................... Is the lock-bolt of compressor loosened?
• Insulation Is the unit fully insulated?
• Ground Is the unit safely grounded?

10.5 Checking the Drainage


1. Remove the Air Filter. 2. Check the drainage.
• Spray one or two glasses of water upon the
evaporator.
• Ensure that water flows drain hose of indoor unit
without any leakage.

20 _ Ceiling Concealed Duct_Built in (Low Static)


10. Installation
CAUTION
1. Install declination of the indoor unit is very important for the drain of the duct type air condition-
er.
2. Minimum thickness of the insulation for the connecting pipe shall be 19mm.

Front of view
• The unit must be horizontal or declined to the drain hose connected when finished
installation.
Ceiling

Drainage hole

Indoor Units
Drain Pump use

10.6 Drain Piping


• Drain piping must have down-slope (1/50 to 1/100): be sure not to Upward
Pipe clamp
provide up-and-down slope to prevent reversal flow. routing
• During drain piping connection, be careful not to exert extra force not allowed
Indoor unit
on the drain port on the indoor unit.
• The outside diameter of the drain connection on the indoor unit is
32mm.
Piping material: Polyvinyl chloride pipe VP-25 and
pipe fittings Maintenance
drain port
• Be sure to install heat insulation on the drain piping.
Heat insulation material: Polyethylene foam with thick-
1/50~1/100
ness more than 8 mm.
MAX 700mm
Drain test
The air conditioner uses a drain pump to drain water.
Use the following procedure to test the drain pump operation:

Feed water Flexible drain hose


• Connect the main drain pipe to the exterior and
leave it provisionally until the test comes to an
Main
drain pipe end.
• Feed water to the flexible drain hose and check
Drain the piping for leakage.
Drain Pump port Glue the joint • Be sure to check the drain pump for normal oper-
ating and noise when electrical wiring is complete.
Drain hose connection
Use the clip • When the test is complete, connect the flexible
drain hose to the drain port on the indoor unit.

Drain pan

Ceiling Concealed Duct_Built in (Low Static) _ 21


10. Installation
CAUTION : The supplied flexible drain Hanger
Max 300mm distance Hanger Bracket
hose should not be curved, neither 1~15m 1/50~1/100 slope
screwed. The curved or screwed hose Metal

Max 700mm
may cause a leakage of water. clamp

Flexible drain hose


Insulation

CAUTION:
After the confirmation of the above conditions, prepare the wiring as follows:
1) Never fail to have an individual power specialized for the air conditioner. As for the method of
wiring, be guided by the circuit diagram posted on the inside of control box cover.
2) Provide a circuit breaker switch between power source and the unit.
3) The screws which fasten the wiring in the casing of electrical fittings are liable to come loose
Indoor Units

from vibrations to which the unit is subjected during the course of transportation. Check them
and make sure that they are all tightly fastened. (If they are loose, it could give rise to burn-out
of the wires.) Flexible drain hose

4) Specification of power source


5) Confirm that electrical capacity is sufficient.
6) Be sure that the starting voltage is maintained at more than 90 percent of the rated voltage
marked on the name plate.
7) Confirm that the cable thickness is as specified in the power sources specification.
(Particularly note the relation between cable length and thickness.)
8) Never fail to equip a leakage breaker where it is wet or moist.
9) The following troubles would be caused by voltage drop-down.
• Vibration of a magnetic switch, damage on the contact point, fuse breaking, disturbance by the nor-
mal function of an overload protection device.
• Proper starting power is not given to the compressor.

HAND OVER
Teach the customer the operation and maintenance procedures, using the operation manual.
(air filter cleaning, temperature control, etc.)

22 _ Ceiling Concealed Duct_Built in (Low Static)


10. Installation

WIRED REMOTE CONTROLLER INSTALLATION


• Since the room temperature sensor is in the remote controller, the remote controller box should be installed in a place
away from direct sunlight, high humidity and direct supply of cold air to maintain proper space temperature.
Install the remote controller about 5ft(1.5m) above the floor in an area with good air circulation at an average tempera-
ture.
Do not install the remote controller where it can be affected by:
- Drafts, or dead spots behind doors and in corners.
- Hot or cold air from ducts.
- Radiant heat from sun or appliances.
- Concealed pipes and chimneys.
- Uncontrolled areas such as an outside wall behind the remote controller.
- This remote controller is equipped with a seven segment LED. display. For proper display of the remote controller
LED's, the remote controller should be installed properly as shown in Fig.1.
(The standard height is 1.2~1.5 m from floor level.)

Indoor Units
Remote Controller
TEMP
yes

no
TEMP

Remote Controller

no
TEMP
5feet
Remote
Controller

(1.5meters)
no

Fig.1 Typical locations for remote controller

Ceiling Concealed Duct_Built in (Low Static) _ 23


11. Accessories
Standard Accessories
Washer for Clamp Insulation for
Name Drain hose Clamp metal (Other)
hanging backet (Tie Wrap) fitting

Quantity 1 EA 2 EA 8 EA 4 EA 1 SET

• Owner's manual
• Installation manual

Shape for gas pipe

for liquid pipe


Indoor Units

CAUTION
• Use only those accessories (Standard or optional) which have designated specilications.

24 _ Ceiling Concealed Duct_Built in (Low Static)


Indoor unit

Wall Mounted (Libero)


1. List of functions

2. Specifications

3. Dimensions

4. Piping Diagrams

5. Wiring Diagrams

6. Capacity Tables

7. Air Velocity and Temperature Distribution

8. Electric Characteristics

9. Sound Levels

10. Installation

11. Accessories
1. List of functions

ARNU05GSB*2, ARNU07GSB*2, ARNU09GSB*2,


Category Function ARNU12GSB*2, ARNU15GSB*2, ARNU18GSC*2,
ARNU24GSC*2
Air supply outlet 1
Airflow direction control(left & right) Manual
Airflow direction control(up & down) Auto
Auto swing(left & right) -
Auto swing(up & down) Auto
Air flow
Airflow steps(fan/cool/heat) 3/4/3
Chaos swing O
Chaos wind(auto wind) -
Jet cool(Power wind) -
Swirl wind -
Deodorizing filter O
Air purifying Plasma air purifier Option
Prefilter(washable / anti-fungus) O
Drain pump -

Indoor Units
E.S.P. control -
Installation
Electric heater(operation) -
High ceiling operation -
Hot start O
Reliability Self diagnosis O
Soft dry operation O
Auto changeover O(Heat recovery)
Auto cleaning O
Auto operation(artificial intelligence) O(Heat pump or Cooling only)
Auto restart operation -
Child lock O
Convenience Forced operation O
Group control O
Sleep mode O
Timer(on/off) O
Timer(weekly) O
Two thermistor control O
Wide wired remote controller PQRCVSL0/PQRCVSL0QW
Deluxe wired remote controller X
Individual
Simple wired remote controller PQRCVCL0Q(W)
control
Wired remote controller(for hotel use) PQRCHCA0Q(W)
Wireless LCD remote control PQWRH(C)Q0FDB
Zone control -
CTIE -
Special Electro thermostat -
function kit Remote temperature sensor -
Group control wire PZCWRCG3
Dry contact PQDSA(1)/PQDSB(1)/PQDSBC/PQDSBNGCM1/PQDSBCGCD0

O : Applied X : Not applied – : No relation


Option : Model name & price are different according to options, and assembled in factory with main unit.
Accessory : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate
package.

Wall Mounted (Libero) _ 1


2. Specifications

Type Wall Mounted


Model Unit
ARNU05GSB*2 ARNU07GSB*2 ARNU09GSB*2
kW 1.6 2.2 2.8
Cooling Capacity kcal/h
1,400 1,900 2,400
Btu/h
5,500 7,500 9,600
kW 1.8 2.5 3.2
Heating Capacity kcal/h
1,500 2,200 2,800
Btu/h
6,100 8,500 10,900
895 mm
× 289 × 215 895 × 289 × 215 895 × 289 × 215
Dimensions(WxHxD) Body
inch
35-1/4 × 11-3/8 × 8-15/32 35-1/4 × 11-3/8 × 8-15/32 35-1/4 × 11-3/8 × 8-15/32
Coil Rows x Columns x FPI 2 x 12 x 23 2 x 16 x 23 2 x 16 x 23
Face Area m2 0.16 0.21 0.21
Type Cross Flow Fan Cross Flow Fan Cross Flow Fan
Motor Output x Number W 20 x 1 20 x 1 20 x 1
Running Current A 0.16 0.16 0.16
Fan Air Flow Rate(H / M / L) CMM 6.5 / 6.0 / 5.5 7.0 / 6.5 / 5.5 8.2 / 7.0 / 5.5
Indoor Units

CFM 230 / 212 / 194 247 / 230 / 194 290 / 247 / 194
Drive Direct Direct Direct
Motor type BLDC BLDC BLDC
Temperature Control Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating
Sound Absorbing Thermal Insulation Material Foamed polystrene Foamed polystrene Foamed polystrene
Air Filter Resin Net(washable) Resin Net(washable) Resin Net(washable)
Safety Device Fuse Fuse Fuse
Liquid Side mm(inch) Ø 6.35(1/4) Ø6.35(1/4) Ø6.35(1/4)
Pipe Connections Gas Side mm(inch) Ø 12.7(1/2) Ø12.7(1/2) Ø12.7(1/2)
Drain Pipe(ID) mm 16(5/8) 16 (5/8) 16 (5/8)
Net Weight kg(lbs) 10.0 (22.0) 10.0 (22.0) 10.0 (22.0)
Noise Level(Sound Press, 1m, H / M / L) dB(A) 30 / 29 / 28 32 / 30 / 28 34 / 32 / 28
Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50
1, 220, 60 1, 220, 60 1, 220, 60
Refrigerant Control EEV EEV EEV
Power cable mm2 CV2.5 x 3C CV2.5 x 3C CV2.5 x 3C
Transmission cable mm2 1.0 ~ 1.5 × 2C 1.0 ~ 1.5 × 2C 1.0 ~ 1.5 × 2C
Color White White White

Notes:- Conversion Formula


1. Capacities are based on the following conditions:
Cooling • Indoor temp. 27°C[80.6°F]DB/ 19°C[66.2°F]WB kcal/h= kW x 860
• Outdoor temp. 35°C[95°F]DB/ 24°C[75.2°F]WB Btu/h = kW x 3412
• Interconnecting Piping Length 7.5m cfm = m3/min x 35.3
• Level Difference of Zero l/s = CMM x 1000/60
Heating • Indoor temp. 20°C[68°F]DB/ 15°C[59°F]WB
• Outdoor temp. 7°C[44.6°F]DB/ 6°C[42.8°F]WB
• Interconnecting Piping Length 7.5m
• Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve
6. Anechoic chamber conversion value is measured at 1 m downward from unit centre.
The values depends on the ambient conditions and values are normally higher in actual operation.

2 _ Wall Mounted (Libero)


2. Specifications

Type Wall Mounted


Model Unit ARNU12GSB*2 ARNU15GSB*2
kW 3.6 4.5
Cooling Capacity kcal/h 3,100 3,900
Btu/h 12,300 15,400
kW 4.0 5.0
Heating Capacity kcal/h 3,400 4,300
Btu/h 13,600 17,100
mm 895 × 289 × 215 895 × 289 × 215
Dimensions(WxHxD) Body
inch 35-1/4 × 11-3/8 × 8-15/32 35-1/4 × 11-3/8 × 8-15/32
Coil Rows x Columns x FPI 2 x 16 x 23 2 x 16 x 23
Face Area m2 0.21 0.21
Type Cross Flow Fan Cross Flow Fan
Motor Output x Number W 20 x 1 20 x 1
Running Current A 0.16 0.16
Fan Air Flow Rate(H / M / L) CMM 9.5 / 8.2 / 6.5 10.5 / 9.0 / 7.0

Indoor Units
CFM 336 / 290 / 230 371 / 318 / 247
Drive Direct Direct
Motor type BLDC BLDC
Temperature Control Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating
Sound Absorbing Thermal Insulation Material Foamed polystrene Foamed polystrene
Air Filter Resin Net(washable) Resin Net(washable)
Safety Device Fuse Fuse
Liquid Side mm(inch) Ø6.35(1/4) Ø6.35(1/4)
Pipe Connections Gas Side mm(inch) Ø12.7(1/2) Ø12.7(1/2)
Drain Pipe(ID) mm 16 (5/8) 16 (5/8)
Net Weight kg(lbs) 10.0 (22.0) 10.0 (22.0)
Noise Level(Sound Press, 1m, H / M / L) dB(A) 37 / 34 / 30 40 / 36 / 32
Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50
1, 220, 60 1, 220, 60
Refrigerant Control EEV EEV
Power cable mm2 CV2.5 x 3C CV2.5 x 3C
Transmission cable mm2 1.0 ~ 1.5 × 2C 1.0 ~ 1.5 × 2C
Color White White

Notes:- Conversion Formula


1. Capacities are based on the following conditions:
Cooling • Indoor temp. 27°C[80.6°F]DB/ 19°C[66.2°F]WB kcal/h= kW x 860
• Outdoor temp. 35°C[95°F]DB/ 24°C[75.2°F]WB Btu/h = kW x 3412
• Interconnecting Piping Length 7.5m cfm = m3/min x 35.3
• Level Difference of Zero l/s = CMM x 1000/60
Heating • Indoor temp. 20°C[68°F]DB/ 15°C[59°F]WB
• Outdoor temp. 7°C[44.6°F]DB/ 6°C[42.8°F]WB
• Interconnecting Piping Length 7.5m
• Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve
6. Anechoic chamber conversion value is measured at 1 m downward from unit centre.
The values depends on the ambient conditions and values are normally higher in actual operation.

Wall Mounted (Libero) _ 3


3. Dimensions

Type Wall Mounted


Model Unit ARNU18GSC*2 ARNU24GSC*2
kW 5.6 7.1
Cooling Capacity kcal/h 4,800 6,100
Btu/h 19,100 24,200
kW 6.3 8.0
Heating Capacity kcal/h 5,400 6,900
Btu/h 21,500 27,300
mm 1,030 × 325 × 255 1,030 × 325 × 255
Dimensions(WxHxD) Body
inch 40-9/16 × 12-25/32 × 10-1/32 40-9/16 × 12-25/32 × 10-1/32
Coil Rows x Columns x FPI 2 x 18 x 22 + 1 x 4 x 21 2 x 18 x 22 + 1 x 4 x 21
Face Area m2 0.28 0.28
Type Cross Flow Fan Cross Flow Fan
Motor Output x Number W 76 x 1 76 x 1
Running Current A 0.29 0.29
Fan Air Flow Rate(H / M / L) CMM 12.5 / 12.0 / 11.3 14.0 / 12.7 / 11.5
Indoor Units

CFM 441 / 424 / 399 494 / 449 / 406


Drive Direct Direct
Motor type BLDC BLDC
Temperature Control Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating
Sound Absorbing Thermal Insulation Material Foamed polystrene Foamed polystrene
Air Filter Resin Net(washable) Resin Net(washable)
Safety Device Fuse Fuse
Liquid Side mm(inch) Ø6.35(1/4) Ø9.52(3/8)
Pipe Connections Gas Side mm(inch) Ø12.7(1/2) Ø15.88(5/8)
Drain Pipe(ID) mm 16 (5/8) 16 (5/8)
Net Weight kg(lbs) 14.0 (30.9) 14.0 (30.9)
Noise Level(Sound Press, 1m, H / M / L) dB(A) 38 / 35 / 33 43 / 39 / 35
Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50
1, 220, 60 1, 220, 60
Refrigerant Control EEV EEV
Power cable mm2 CV2.5 x 3C CV2.5 x 3C
Transmission cable mm2 1.0 ~ 1.5 × 2C 1.0 ~ 1.5 × 2C
Color White White

Notes:- Conversion Formula


1. Capacities are based on the following conditions:
Cooling • Indoor temp. 27°C[80.6°F]DB/ 19°C[66.2°F]WB kcal/h= kW x 860
• Outdoor temp. 35°C[95°F]DB/ 24°C[75.2°F]WB Btu/h = kW x 3412
• Interconnecting Piping Length 7.5m cfm = m3/min x 35.3
• Level Difference of Zero l/s = CMM x 1000/60
Heating • Indoor temp. 20°C[68°F]DB/ 15°C[59°F]WB
• Outdoor temp. 7°C[44.6°F]DB/ 6°C[42.8°F]WB
• Interconnecting Piping Length 7.5m
• Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve
6. Anechoic chamber conversion value is measured at 1 m downward from unit centre.
The values depends on the ambient conditions and values are normally higher in actual operation.

4 _ Wall Mounted (Libero)


Wall Mounted

ARNU05GSB*2 ARNU12GSB*2
341 323 128
ARNU07GSB*2 ARNU15GSB*2
ARNU09GSB*2
3. Dimensions

No. Part Name Remark


895 1 Front panel
205
2 Display & signal receiver
3 Air suction grille
4 Knockout hole
5 Installation plate

289
50

37
45
790 210

Note
1. Unit should be installed in compliance with the installation manual
in the product box.
675 2. Unit shall be grounded in accordance with the local regulations or
327 applicable national codes.

264
422 70

76, Seongsan-dong, Changwon City, Gyeongnam,


641-713, Korea CHASSIS CODE: SB

Wall Mounted (Libero) _ 5


Indoor Units
Indoor Units

Wall Mounted

ARNU18GSC*2
[Unit : mm] ARNU24GSC*2

210
1030
250
3. Dimensions

No. Part Name Remark

6 _ Wall Mounted (Libero)


1 Front panel
2 Display & signal receiver

325
3 Air suction grille
4 Knockout hole
5 Installation plate

Place a level on raised tab


Unit Outline
460 570 Note
1. Unit should be installed in compliance with the installation manual
in the product box.
2. Unit shall be grounded in accordance with the local regulations or
applicable national codes.

ÿ 70
ÿ 70 Installation Plate
Left rear Measuring Tape Right rear
piping piping
69 56

105 Measuring Tape 207


Hanger

76, Seongsan-dong, Changwon City, Gyeongnam,


641-713, Korea CHASSIS CODE: SC
4. Piping Diagrams

:Cooling
Heat Exchanger EEV :Heating
Filter

Th3 Th2
C.F.F Filter

Th1 lndoor unit

Indoor Units
Refrigerant pipe connection port diameter

[Unit: mm(inch)]

MODEL GAS LIQUID


ARNU05GSB*2 Ø12.7(1/2) Ø6.35(1/4)
ARNU07GSB*2 Ø12.7(1/2) Ø6.35(1/4)
ARNU09GSB*2 Ø12.7(1/2) Ø6.35(1/4)
ARNU12GSB*2 Ø12.7(1/2) Ø6.35(1/4)
ARNU15GSB*2 Ø12.7(1/2) Ø6.35(1/4)
ARNU18GSC*2 Ø12.7(1/2) Ø6.35(1/4)
ARNU24GSC*2 Ø15.88(5/8) Ø9.52(3/8)

LOC. Description
Th1 Room thermistor
Th2 Pipe in thermistor
Th3 Pipe out thermistor

Wall Mounted (Libero) _ 7


5. Wiring Diagrams
SB/SC Chassis
Indoor Units

CONNECTOR NUMBER LOCATION POINT FUNCTION


CN-POWER AC Power supply AC Power line input for indoor
CN-MOTOR Fan motor output Motor output of BLDC
CN-485 Communication Connection between indoor
CN-DISP1 Display Display of indoor status
CN-DISP2 Display Display of indoor status
CN-LEV EEV output EEV control output
CN-U/D Step motor Step motor output
CN-TH1 Room/inlet pipe sensor Room and inlet pipe thermistor
CN-TH2 Outlet pipe sensor Outlet pipe thermistor
CN-REMO Remote controller Remote control line
CN-CC Dry contact Dry contact line
CN-HVB Air clean Air clean control

8 _ Wall Mounted (Libero)


6. Capacity Tables
6.1 Cooling Capacity
Cooling Capacity

Indoor air temp. (DB/WB, °C)


Capacity Outdoor 20 23 26 27 28 30 32
Index air temp. 14 16 18 19 20 22 24
(DB, °C) TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10 1.1 1.0 1.3 1.0 1.5 1.1 1.6 1.2 1.7 1.2 1.9 1.3 2.1 1.2
12 1.1 1.0 1.3 1.0 1.5 1.1 1.6 1.2 1.7 1.2 1.9 1.3 2.1 1.2
14 1.1 1.0 1.3 1.0 1.5 1.1 1.6 1.2 1.7 1.2 1.9 1.3 2.1 1.2
16 1.1 1.0 1.3 1.0 1.5 1.1 1.6 1.2 1.7 1.2 1.9 1.3 2.0 1.2
18 1.1 1.0 1.3 1.0 1.5 1.1 1.6 1.2 1.7 1.2 1.9 1.3 2.0 1.2
20 1.1 1.0 1.3 1.0 1.5 1.1 1.6 1.2 1.7 1.2 1.9 1.3 2.0 1.2
21 1.1 1.0 1.3 1.0 1.5 1.1 1.6 1.2 1.7 1.2 1.9 1.3 2.0 1.2
23 1.1 1.0 1.3 1.0 1.5 1.1 1.6 1.2 1.7 1.2 1.9 1.3 1.9 1.1
1.6 25 1.1 1.0 1.3 1.0 1.5 1.1 1.6 1.2 1.7 1.2 1.9 1.2 1.9 1.1
27 1.1 1.0 1.3 1.0 1.5 1.1 1.6 1.2 1.7 1.2 1.8 1.2 1.9 1.1
29 1.1 1.0 1.3 1.0 1.5 1.1 1.6 1.2 1.7 1.2 1.8 1.2 1.8 1.1

Indoor Units
31 1.1 1.0 1.3 1.0 1.5 1.1 1.6 1.2 1.7 1.2 1.8 1.2 1.8 1.1
33 1.1 1.0 1.3 1.0 1.5 1.1 1.6 1.2 1.7 1.2 1.8 1.2 1.8 1.0
35 1.1 1.0 1.3 1.0 1.5 1.1 1.6 1.2 1.7 1.2 1.7 1.1 1.8 1.0
37 1.1 1.0 1.3 1.0 1.5 1.1 1.6 1.2 1.7 1.2 1.7 1.1 1.7 1.0
39 1.1 1.0 1.3 1.0 1.5 1.1 1.6 1.2 1.6 1.1 1.7 1.1 1.7 1.0
10 1.5 1.3 1.8 1.4 2.0 1.6 2.2 1.6 2.4 1.7 2.6 1.7 2.9 1.7
12 1.5 1.3 1.8 1.4 2.0 1.6 2.2 1.6 2.4 1.7 2.6 1.7 2.9 1.7
14 1.5 1.3 1.8 1.4 2.0 1.6 2.2 1.6 2.4 1.7 2.6 1.7 2.8 1.7
16 1.5 1.3 1.8 1.4 2.0 1.6 2.2 1.6 2.4 1.7 2.6 1.7 2.8 1.6
18 1.5 1.3 1.8 1.4 2.0 1.6 2.2 1.6 2.4 1.7 2.6 1.7 2.7 1.6
20 1.5 1.3 1.8 1.4 2.0 1.6 2.2 1.6 2.4 1.7 2.6 1.7 2.7 1.6
21 1.5 1.3 1.8 1.4 2.0 1.6 2.2 1.6 2.4 1.7 2.6 1.7 2.7 1.6
23 1.5 1.3 1.8 1.4 2.0 1.6 2.2 1.6 2.4 1.7 2.6 1.7 2.6 1.6
2.2 25 1.5 1.3 1.8 1.4 2.0 1.6 2.2 1.6 2.4 1.7 2.6 1.7 2.6 1.5
27 1.5 1.3 1.8 1.4 2.0 1.6 2.2 1.6 2.4 1.7 2.5 1.7 2.6 1.5
29 1.5 1.3 1.8 1.4 2.0 1.6 2.2 1.6 2.4 1.7 2.5 1.6 2.5 1.5
31 1.5 1.3 1.8 1.4 2.0 1.6 2.2 1.6 2.4 1.7 2.5 1.6 2.5 1.5
33 1.5 1.3 1.8 1.4 2.0 1.6 2.2 1.6 2.4 1.7 2.4 1.6 2.4 1.4
35 1.5 1.3 1.8 1.4 2.0 1.6 2.2 1.6 2.4 1.7 2.4 1.6 2.4 1.4
37 1.5 1.3 1.8 1.4 2.0 1.6 2.2 1.6 2.3 1.6 2.3 1.5 2.4 1.4
39 1.5 1.3 1.8 1.4 2.0 1.6 2.2 1.6 2.2 1.6 2.3 1.5 2.4 1.4
10 1.9 1.6 2.2 1.7 2.6 1.9 2.8 1.9 3.0 2.0 3.4 2.1 3.7 2.0
12 1.9 1.6 2.2 1.7 2.6 1.9 2.8 1.9 3.0 2.0 3.4 2.1 3.6 2.0
14 1.9 1.6 2.2 1.7 2.6 1.9 2.8 1.9 3.0 2.0 3.4 2.1 3.6 2.0
16 1.9 1.6 2.2 1.7 2.6 1.9 2.8 1.9 3.0 2.0 3.4 2.1 3.5 2.0
18 1.9 1.6 2.2 1.7 2.6 1.9 2.8 1.9 3.0 2.0 3.4 2.1 3.5 2.0
20 1.9 1.6 2.2 1.7 2.6 1.9 2.8 1.9 3.0 2.0 3.4 2.1 3.4 1.9
21 1.9 1.6 2.2 1.7 2.6 1.9 2.8 1.9 3.0 2.0 3.4 2.1 3.4 1.9
23 1.9 1.6 2.2 1.7 2.6 1.9 2.8 1.9 3.0 2.0 3.4 2.1 3.4 1.9
2.8 25 1.9 1.6 2.2 1.7 2.6 1.9 2.8 1.9 3.0 2.0 3.3 2.0 3.3 1.9
27 1.9 1.6 2.2 1.7 2.6 1.9 2.8 1.9 3.0 2.0 3.2 2.0 3.3 1.9
29 1.9 1.6 2.2 1.7 2.6 1.9 2.8 1.9 3.0 2.0 3.2 2.0 3.2 1.8
31 1.9 1.6 2.2 1.7 2.6 1.9 2.8 1.9 3.0 2.0 3.2 1.9 3.2 1.8
33 1.9 1.6 2.2 1.7 2.6 1.9 2.8 1.9 3.0 2.0 3.1 1.9 3.1 1.7
35 1.9 1.6 2.2 1.7 2.6 1.9 2.8 1.9 3.0 2.0 3.0 1.9 3.1 1.7
37 1.9 1.6 2.2 1.7 2.6 1.9 2.8 1.9 2.9 1.9 3.0 1.9 3.0 1.7
39 1.9 1.6 2.2 1.7 2.6 1.9 2.8 1.9 2.8 1.9 2.9 1.8 3.0 1.7

Wall Mounted (Libero) _ 9


6. Capacity Tables
Cooling Capacity

Indoor air temp. (DB/WB, °C)


Capacity Outdoor 20 23 26 27 28 30 32
Index air temp. 14 16 18 19 20 22 24
(DB, °C) TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10 2.4 2.0 2.9 2.2 3.3 2.4 3.6 2.4 3.9 2.5 4.3 2.6 4.7 2.6
12 2.4 2.0 2.9 2.2 3.3 2.4 3.6 2.4 3.9 2.5 4.3 2.6 4.7 2.6
14 2.4 2.0 2.9 2.2 3.3 2.4 3.6 2.4 3.9 2.5 4.3 2.6 4.6 2.5
16 2.4 2.0 2.9 2.2 3.3 2.4 3.6 2.4 3.9 2.5 4.3 2.6 4.6 2.5
18 2.4 2.0 2.9 2.2 3.3 2.4 3.6 2.4 3.9 2.5 4.3 2.6 4.5 2.5
20 2.4 2.0 2.9 2.2 3.3 2.4 3.6 2.4 3.9 2.5 4.3 2.6 4.4 2.4
21 2.4 2.0 2.9 2.2 3.3 2.4 3.6 2.4 3.9 2.5 4.3 2.6 4.4 2.4
23 2.4 2.0 2.9 2.2 3.3 2.4 3.6 2.4 3.9 2.5 4.3 2.6 4.3 2.4
3.6 25 2.4 2.0 2.9 2.2 3.3 2.4 3.6 2.4 3.9 2.5 4.3 2.6 4.3 2.4
27 2.4 2.0 2.9 2.2 3.3 2.4 3.6 2.4 3.9 2.5 4.2 2.5 4.2 2.4
29 2.4 2.0 2.9 2.2 3.3 2.4 3.6 2.4 3.9 2.5 4.1 2.5 4.2 2.3
Indoor Units

31 2.4 2.0 2.9 2.2 3.3 2.4 3.6 2.4 3.9 2.5 4.1 2.4 4.1 2.3
33 2.4 2.0 2.9 2.2 3.3 2.4 3.6 2.4 3.9 2.5 4.0 2.4 4.0 2.2
35 2.4 2.0 2.9 2.2 3.3 2.4 3.6 2.4 3.9 2.5 3.9 2.4 4.0 2.2
37 2.4 2.0 2.9 2.2 3.3 2.4 3.6 2.4 3.8 2.4 3.8 2.4 3.9 2.2
39 2.4 2.0 2.9 2.2 3.3 2.4 3.6 2.4 3.7 2.4 3.8 2.3 3.9 2.1
10 3.0 2.6 3.6 2.8 4.2 3.0 4.5 3.1 4.8 3.2 5.4 3.3 5.9 3.3
12 3.0 2.6 3.6 2.8 4.2 3.0 4.5 3.1 4.8 3.2 5.4 3.3 5.8 3.3
14 3.0 2.6 3.6 2.8 4.2 3.0 4.5 3.1 4.8 3.2 5.4 3.3 5.8 3.2
16 3.0 2.6 3.6 2.8 4.2 3.0 4.5 3.1 4.8 3.2 5.4 3.3 5.7 3.2
18 3.0 2.6 3.6 2.8 4.2 3.0 4.5 3.1 4.8 3.2 5.4 3.3 5.6 3.2
20 3.0 2.6 3.6 2.8 4.2 3.0 4.5 3.1 4.8 3.2 5.4 3.3 5.5 3.1
21 3.0 2.6 3.6 2.8 4.2 3.0 4.5 3.1 4.8 3.2 5.4 3.3 5.5 3.1
23 3.0 2.6 3.6 2.8 4.2 3.0 4.5 3.1 4.8 3.2 5.4 3.3 5.4 3.0
4.5 25 3.0 2.6 3.6 2.8 4.2 3.0 4.5 3.1 4.8 3.2 5.3 3.3 5.3 3.0
27 3.0 2.6 3.6 2.8 4.2 3.0 4.5 3.1 4.8 3.2 5.2 3.2 5.3 3.0
29 3.0 2.6 3.6 2.8 4.2 3.0 4.5 3.1 4.8 3.2 5.1 3.2 5.2 2.9
31 3.0 2.6 3.6 2.8 4.2 3.0 4.5 3.1 4.8 3.2 5.1 3.1 5.1 2.9
33 3.0 2.6 3.6 2.8 4.2 3.0 4.5 3.1 4.8 3.2 4.9 3.1 5.0 2.8
35 3.0 2.6 3.6 2.8 4.2 3.0 4.5 3.1 4.8 3.2 4.9 3.0 4.9 2.8
37 3.0 2.6 3.6 2.8 4.2 3.0 4.5 3.1 4.7 3.1 4.8 3.0 4.9 2.7
39 3.0 2.6 3.6 2.8 4.2 3.0 4.5 3.1 4.6 3.0 4.7 2.9 4.8 2.7
10 3.8 3.1 4.5 3.4 5.2 3.7 5.6 3.8 6.0 3.9 6.7 4.0 7.3 4.0
12 3.8 3.1 4.5 3.4 5.2 3.7 5.6 3.8 6.0 3.9 6.7 4.0 7.3 4.0
14 3.8 3.1 4.5 3.4 5.2 3.7 5.6 3.8 6.0 3.9 6.7 4.0 7.2 3.9
16 3.8 3.1 4.5 3.4 5.2 3.7 5.6 3.8 6.0 3.9 6.7 4.0 7.1 3.8
18 3.8 3.1 4.5 3.4 5.2 3.7 5.6 3.8 6.0 3.9 6.7 4.0 6.9 3.8
20 3.8 3.1 4.5 3.4 5.2 3.7 5.6 3.8 6.0 3.9 6.7 4.0 6.9 3.8
21 3.8 3.1 4.5 3.4 5.2 3.7 5.6 3.8 6.0 3.9 6.7 4.0 6.9 3.8
23 3.8 3.1 4.5 3.4 5.2 3.7 5.6 3.8 6.0 3.9 6.7 4.0 6.7 3.7
5.6 25 3.8 3.1 4.5 3.4 5.2 3.7 5.6 3.8 6.0 3.9 6.6 4.0 6.6 3.6
27 3.8 3.1 4.5 3.4 5.2 3.7 5.6 3.8 6.0 3.9 6.5 3.9 6.5 3.6
29 3.8 3.1 4.5 3.4 5.2 3.7 5.6 3.8 6.0 3.9 6.4 3.8 6.5 3.5
31 3.8 3.1 4.5 3.4 5.2 3.7 5.6 3.8 6.0 3.9 6.3 3.8 6.4 3.5
33 3.8 3.1 4.5 3.4 5.2 3.7 5.6 3.8 6.0 3.9 6.2 3.8 6.2 3.4
35 3.8 3.1 4.5 3.4 5.2 3.7 5.6 3.8 6.0 3.9 6.1 3.7 6.2 3.4
37 3.8 3.1 4.5 3.4 5.2 3.7 5.6 3.8 5.8 3.8 5.9 3.6 6.1 3.3
39 3.8 3.1 4.5 3.4 5.2 3.7 5.6 3.8 5.7 3.7 5.8 3.5 6.0 3.2

10 _ Wall Mounted (Libero)


6. Capacity Tables
Cooling Capacity

Indoor air temp. (DB/WB, °C)


Capacity Outdoor 20 23 26 27 28 30 32
Index air temp. 14 16 18 19 20 22 24
(DB, °C) TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10 4.8 4.0 5.7 4.4 6.6 4.7 7.1 4.8 7.6 5.0 8.5 5.2 9.3 5.1
12 4.8 4.0 5.7 4.4 6.6 4.7 7.1 4.8 7.6 5.0 8.5 5.2 9.2 5.1
14 4.8 4.0 5.7 4.4 6.6 4.7 7.1 4.8 7.6 5.0 8.5 5.2 9.1 5.0
16 4.8 4.0 5.7 4.4 6.6 4.7 7.1 4.8 7.6 5.0 8.5 5.2 9.0 4.9
18 4.8 4.0 5.7 4.4 6.6 4.7 7.1 4.8 7.6 5.0 8.5 5.2 8.8 4.9
20 4.8 4.0 5.7 4.4 6.6 4.7 7.1 4.8 7.6 5.0 8.5 5.2 8.7 4.8
21 4.8 4.0 5.7 4.4 6.6 4.7 7.1 4.8 7.6 5.0 8.5 5.2 8.7 4.8
23 4.8 4.0 5.7 4.4 6.6 4.7 7.1 4.8 7.6 5.0 8.5 5.2 8.5 4.7
7.1 25 4.8 4.0 5.7 4.4 6.6 4.7 7.1 4.8 7.6 5.0 8.4 5.1 8.4 4.6
27 4.8 4.0 5.7 4.4 6.6 4.7 7.1 4.8 7.6 5.0 8.2 5.0 8.3 4.6
29 4.8 4.0 5.7 4.4 6.6 4.7 7.1 4.8 7.6 5.0 8.1 4.9 8.2 4.5

Indoor Units
31 4.8 4.0 5.7 4.4 6.6 4.7 7.1 4.8 7.6 5.0 8.0 4.8 8.1 4.4
33 4.8 4.0 5.7 4.4 6.6 4.7 7.1 4.8 7.6 5.0 7.8 4.8 7.9 4.4
35 4.8 4.0 5.7 4.4 6.6 4.7 7.1 4.8 7.6 5.0 7.7 4.7 7.8 4.4
37 4.8 4.0 5.7 4.4 6.6 4.7 7.1 4.8 7.4 4.8 7.5 4.6 7.7 4.3
39 4.8 4.0 5.7 4.4 6.6 4.7 7.1 4.8 7.2 4.7 7.4 4.5 7.6 4.2

Notes:
TC: Total Capacity(kW), SHC: Sensible Heat Capacity(kW) 2. Refer to Capacity Correction Factor in the outdoor unit PDB for
1. Capacity tables show the representative value of conditions the actual performance data of each indoor unit and outdoor unit
which may occur. combination.

Wall Mounted (Libero) _ 11


6. Capacity Tables
6.2 Heating Capacity Heating Capacity

Outdoor air Indoor air temp. (DB, °C)


Capacity temp. 16 18 20 21 22 24
Index TC TC TC TC TC TC
DB(°C) WB(°C)
kW kW kW kW kW kW
-24.8 -25.0 1.0 1.0 1.0 1.0 1.0 1.0
-21.8 -22.0 1.3 1.3 1.3 1.3 1.3 1.2
-19.8 -20.0 1.3 1.3 1.3 1.3 1.3 1.3
-18.8 -19.0 1.4 1.3 1.3 1.3 1.3 1.3
-16.7 -17.0 1.4 1.4 1.4 1.4 1.4 1.4
-14.7 -15.0 1.5 1.5 1.5 1.5 1.5 1.5
-12.6 -13.0 1.6 1.6 1.6 1.6 1.5 1.5
-10.5 -11.0 1.6 1.6 1.6 1.6 1.6 1.6
-9.5 -10.0 1.7 1.7 1.7 1.7 1.7 1.6
-8.5 -9.1 1.7 1.7 1.7 1.7 1.7 1.6
-7.0 -7.6 1.7 1.7 1.7 1.7 1.7 1.6
1.6 -5.0 -5.6 1.8 1.8 1.8 1.7 1.7 1.6
-3.0 -3.7 1.9 1.8 1.8 1.7 1.7 1.6
0.0 -0.7 1.9 1.9 1.8 1.7 1.7 1.6
Indoor Units

3.0 2.2 2.0 1.9 1.8 1.7 1.7 1.6


5.0 4.1 2.0 1.9 1.8 1.7 1.7 1.6
7.0 6.0 2.0 1.9 1.8 1.7 1.7 1.6
9.0 7.9 2.0 1.9 1.8 1.7 1.7 1.6
11.0 9.8 2.0 1.9 1.8 1.7 1.7 1.6
13.0 11.8 2.0 1.9 1.8 1.7 1.7 1.6
15.0 13.7 2.0 1.9 1.8 1.7 1.7 1.6
-24.8 -25.0 1.4 1.4 1.4 1.4 1.4 1.4
-21.8 -22.0 1.7 1.7 1.7 1.7 1.7 1.7
-19.8 -20.0 1.8 1.8 1.8 1.8 1.8 1.8
-18.8 -19.0 1.9 1.9 1.9 1.9 1.9 1.9
-16.7 -17.0 2.0 2.0 2.0 2.0 2.0 2.0
-14.7 -15.0 2.1 2.1 2.1 2.1 2.1 2.0
-12.6 -13.0 2.2 2.2 2.2 2.2 2.1 2.1
-10.5 -11.0 2.3 2.3 2.2 2.2 2.2 2.2
-9.5 -10.0 2.3 2.3 2.3 2.3 2.3 2.2
-8.5 -9.1 2.3 2.3 2.3 2.3 2.3 2.2
2.2 -7.0 -7.6 2.4 2.4 2.4 2.4 2.3 2.2
-5.0 -5.6 2.5 2.5 2.5 2.4 2.3 2.2
-3.0 -3.7 2.6 2.6 2.5 2.4 2.3 2.2
0.0 -0.7 2.7 2.6 2.5 2.4 2.3 2.2
3.0 2.2 2.7 2.7 2.5 2.4 2.3 2.2
5.0 4.1 2.8 2.7 2.5 2.4 2.3 2.2
7.0 6.0 2.8 2.7 2.5 2.4 2.3 2.2
9.0 7.9 2.8 2.7 2.5 2.4 2.3 2.2
11.0 9.8 2.8 2.7 2.5 2.4 2.3 2.2
13.0 11.8 2.8 2.7 2.5 2.4 2.3 2.2
15.0 13.7 2.8 2.7 2.5 2.4 2.3 2.2
-24.8 -25.0 1.9 1.9 1.8 1.8 1.8 1.8
-21.8 -22.0 2.2 2.2 2.2 2.2 2.2 2.2
-19.8 -20.0 2.4 2.4 2.3 2.3 2.3 2.3
-18.8 -19.0 2.4 2.4 2.4 2.4 2.4 2.4
-16.7 -17.0 2.5 2.5 2.5 2.5 2.5 2.5
-14.7 -15.0 2.7 2.7 2.6 2.6 2.6 2.6
-12.6 -13.0 2.8 2.8 2.8 2.8 2.7 2.7
-10.5 -11.0 2.9 2.9 2.9 2.9 2.9 2.8
-9.5 -10.0 3.0 3.0 2.9 2.9 2.9 2.8
-8.5 -9.1 3.0 3.0 3.0 3.0 3.0 2.8
-7.0 -7.6 3.1 3.1 3.1 3.1 3.0 2.8
2.8 -5.0 -5.6 3.2 3.2 3.2 3.1 3.0 2.8
-3.0 -3.7 3.4 3.3 3.2 3.1 3.0 2.8
0.0 -0.7 3.4 3.3 3.2 3.1 3.0 2.8
3.0 2.2 3.5 3.4 3.2 3.1 3.0 2.8
5.0 4.1 3.6 3.4 3.2 3.1 3.0 2.8
7.0 6.0 3.6 3.4 3.2 3.1 3.0 2.8
9.0 7.9 3.6 3.4 3.2 3.1 3.0 2.8
11.0 9.8 3.6 3.4 3.2 3.1 3.0 2.8
13.0 11.8 3.6 3.4 3.2 3.1 3.0 2.8
15.0 13.7 3.6 3.4 3.2 3.1 3.0 2.8

12 _ Wall Mounted (Libero)


6. Capacity Tables
Heating capacity

Outdoor air Indoor air temp. (DB, °C)


Capacity temp. 16 18 20 21 22 24
Index TC TC TC TC TC TC
DB(°C) WB(°C)
kW kW kW kW kW kW
-24.8 -25.0 2.3 2.3 2.3 2.3 2.3 2.3
-21.8 -22.0 2.8 2.8 2.8 2.8 2.8 2.8
-19.8 -20.0 2.9 2.9 2.9 2.9 2.9 2.9
-18.8 -19.0 3.0 3.0 3.0 3.0 3.0 3.0
-16.7 -17.0 3.1 3.1 3.1 3.1 3.1 3.1
-14.7 -15.0 3.3 3.3 3.3 3.3 3.3 3.3
-12.6 -13.0 3.5 3.4 3.4 3.4 3.4 3.4
-10.5 -11.0 3.6 3.6 3.6 3.6 3.6 3.5
-9.5 -10.0 3.7 3.7 3.7 3.7 3.7 3.5
-8.5 -9.1 3.8 3.8 3.7 3.7 3.7 3.5
-7.0 -7.6 3.9 3.9 3.9 3.8 3.7 3.5
3.6 -5.0 -5.6 4.0 4.0 4.0 3.9 3.7 3.5
-3.0 -3.7 4.2 4.1 4.0 3.9 3.7 3.5
0.0 -0.7 4.3 4.1 4.0 3.9 3.7 3.5
3.0 2.2 4.4 4.3 4.0 3.9 3.7 3.5

Indoor Units
5.0 4.1 4.5 4.3 4.0 3.9 3.7 3.5
7.0 6.0 4.5 4.3 4.0 3.9 3.7 3.5
9.0 7.9 4.5 4.3 4.0 3.9 3.7 3.5
11.0 9.8 4.5 4.3 4.0 3.9 3.7 3.5
13.0 11.8 4.5 4.3 4.0 3.9 3.7 3.5
15.0 13.7 4.5 4.3 4.0 3.9 3.7 3.5
-24.8 -25.0 2.9 2.9 2.9 2.9 2.9 2.9
-21.8 -22.0 3.5 3.5 3.5 3.5 3.5 3.5
-19.8 -20.0 3.7 3.7 3.7 3.7 3.7 3.6
-18.8 -19.0 3.8 3.7 3.7 3.7 3.7 3.7
-16.7 -17.0 3.9 3.9 3.9 3.9 3.9 3.9
-14.7 -15.0 4.1 4.1 4.1 4.1 4.1 4.1
-12.6 -13.0 4.3 4.3 4.3 4.3 4.3 4.3
-10.5 -11.0 4.5 4.5 4.5 4.5 4.5 4.4
-9.5 -10.0 4.6 4.6 4.6 4.6 4.6 4.4
-8.5 -9.1 4.7 4.7 4.7 4.7 4.7 4.4
4.5 -7.0 -7.6 4.8 4.8 4.8 4.8 4.7 4.4
-5.0 -5.6 5.0 5.0 5.0 4.8 4.7 4.4
-3.0 -3.7 5.3 5.1 5.0 4.8 4.7 4.4
0.0 -0.7 5.3 5.2 5.0 4.8 4.7 4.4
3.0 2.2 5.5 5.3 5.0 4.8 4.7 4.4
5.0 4.1 5.6 5.3 5.0 4.8 4.7 4.4
7.0 6.0 5.6 5.3 5.0 4.8 4.7 4.4
9.0 7.9 5.6 5.3 5.0 4.8 4.7 4.4
11.0 9.8 5.6 5.3 5.0 4.8 4.7 4.4
13.0 11.8 5.6 5.3 5.0 4.8 4.7 4.4
15.0 13.7 5.6 5.3 5.0 4.8 4.7 4.4
-24.8 -25.0 3.6 3.6 3.6 3.6 3.6 3.6
-21.8 -22.0 4.4 4.4 4.4 4.4 4.4 4.4
-19.8 -20.0 4.6 4.6 4.6 4.6 4.6 4.6
-18.8 -19.0 4.8 4.7 4.7 4.7 4.7 4.7
-16.7 -17.0 5.0 5.0 5.0 4.9 4.9 4.9
-14.7 -15.0 5.2 5.2 5.2 5.2 5.2 5.2
-12.6 -13.0 5.5 5.4 5.4 5.4 5.4 5.4
-10.5 -11.0 5.7 5.7 5.7 5.7 5.7 5.5
-9.5 -10.0 5.8 5.8 5.8 5.8 5.8 5.5
-8.5 -9.1 5.9 5.9 5.9 5.9 5.9 5.5
-7.0 -7.6 6.1 6.1 6.1 6.0 5.9 5.5
5.6 -5.0 -5.6 6.3 6.3 6.3 6.1 5.9 5.5
-3.0 -3.7 6.6 6.5 6.3 6.1 5.9 5.5
0.0 -0.7 6.7 6.5 6.3 6.1 5.9 5.5
3.0 2.2 6.9 6.7 6.3 6.1 5.9 5.5
5.0 4.1 7.0 6.7 6.3 6.1 5.9 5.5
7.0 6.0 7.1 6.7 6.3 6.1 5.9 5.5
9.0 7.9 7.1 6.7 6.3 6.1 5.9 5.5
11.0 9.8 7.1 6.7 6.3 6.1 5.9 5.5
13.0 11.8 7.1 6.7 6.3 6.1 5.9 5.5
15.0 13.7 7.1 6.7 6.3 6.1 5.9 5.5

Wall Mounted (Libero) _ 13


6. Capacity Tables
Heating capacity

Outdoor air Indoor air temp. (DB, °C)


Capacity temp. 16 18 20 21 22 24
Index TC TC TC TC TC TC
DB(°C) WB(°C)
kW kW kW kW kW kW
-24.8 -25.0 4.6 4.6 4.6 4.6 4.6 4.6
-21.8 -22.0 5.6 5.6 5.6 5.6 5.6 5.5
-19.8 -20.0 5.9 5.9 5.9 5.9 5.9 5.8
-18.8 -19.0 6.0 6.0 6.0 6.0 6.0 6.0
-16.7 -17.0 6.3 6.3 6.3 6.3 6.3 6.3
-14.7 -15.0 6.6 6.6 6.6 6.6 6.6 6.6
-12.6 -13.0 6.9 6.9 6.9 6.9 6.9 6.9
-10.5 -11.0 7.2 7.2 7.2 7.2 7.2 7.0
-9.5 -10.0 7.4 7.4 7.3 7.3 7.3 7.0
-8.5 -9.1 7.5 7.5 7.5 7.5 7.5 7.0
-7.0 -7.6 7.7 7.7 7.7 7.7 7.5 7.0
7.1 -5.0 -5.6 8.0 8.0 8.0 7.7 7.5 7.0
-3.0 -3.7 8.4 8.2 8.0 7.7 7.5 7.0
0.0 -0.7 8.6 8.3 8.0 7.7 7.5 7.0
3.0 2.2 8.8 8.5 8.0 7.7 7.5 7.0
Indoor Units

5.0 4.1 8.9 8.5 8.0 7.7 7.5 7.0


7.0 6.0 9.0 8.5 8.0 7.7 7.5 7.0
9.0 7.9 9.0 8.5 8.0 7.7 7.5 7.0
11.0 9.8 9.0 8.5 8.0 7.7 7.5 7.0
13.0 11.8 9.0 8.5 8.0 7.7 7.5 7.0
15.0 13.7 9.0 8.5 8.0 7.7 7.5 7.0
Notes:
TC: Total Capacity(kW) 3. In accordance with operation limits of outdoor unit, applicable range of
1. Capacity tables show the representative value of conditions which may occur. capacity tables is different.
2. is shown as reference. When selecting the outdoor units, avoid the 4. Refer to Capacity Correction Factor in the outdoor unit PDB for the actual
outdoor air temperature range shown by . performance data of each indoor unit and outdoor unit combination.

14 _ Wall Mounted (Libero)


7. Air Velocity and Temperature Distribution(Reference Data)
ARNU05GSB*2, ARNU07GSB*2
Cooling Heating
Discharge angle : 15° Discharge angle : 40°

Air velocity [m/s] Air velocity [m/s]


2.7m 2.7m

2m 2m
2.5
2.5
2.0
2.0 1m 1m

1.5 1.5
1.0 1.0
0m 0m
5m 4m 3m 2m 1m 0m 5m 4m 3m 2m 1m 0m

Temperature [°C] Temperature [°C]


2.7m 2.7m

Indoor Units
2m 2m

17
28

1m 1m
19

21 30
28 34 32
0m 0m
5m 4m 3m 2m 1m 0m 5m 4m 3m 2m 1m 0m

ARNU09GSB*2
Cooling Heating
Discharge angle : 15° Discharge angle : 40°

Air velocity [m/s] Air velocity [m/s]


2.7m 2.7m

2m 2m
3.0

2.0 2.5 1m
1m

1.5 2.0
1.5
1.0 1.0 1.5
0m 0m
5m 4m 3m 2m 1m 0m 5m 4m 3m 2m 1m 0m

Temperature [°C] Temperature [°C]


2.7m 2.7m

2m 2m

1m 1m

19 30
21 28 34 32
30
0m 0m
5m 4m 3m 2m 1m 0m 5m 4m 3m 2m 1m 0m

Wall Mounted (Libero) _ 15


7. Air Velocity and Temperature Distribution(Reference Data)
ARNU12GSB*2
Cooling Heating
Discharge angle : 15° Discharge angle : 40°

Air velocity [m/s] Air velocity [m/s]


2.7m 2.7m

2m 2m
3.5

3.0 2.0
1m 1m
2.5

2.0
1.5 1.5
1.0 1.0
0m 0m
5m 4m 3m 2m 1m 0m 5m 4m 3m 2m 1m 0m

Temperature [°C] Temperature [°C]


2.7m 2.7m
Indoor Units

2m 2m
17

1m 1m
19 32
30
21 34
28 32
30
0m 0m
5m 4m 3m 2m 1m 0m 5m 4m 3m 2m 1m 0m

ARNU15GSB*2
Cooling Heating
DDischarge angle : 15° Discharge angle : 40°

Air velocity [m/s] Air velocity [m/s]


2.7m 2.7m

2m 2m
3.0 2.5

2.5
1m 1m
2.0
0.5 2.0
1.5 0.5 1.5
0.5 1.0 1.0
0m 0m
5m 4m 3m 2m 1m 0m 5m 4m 3m 2m 1m 0m

Temperature [°C] Temperature [°C]


2.7m 2.7m

2m 2m
21

1m 1m
28
18
30 34
20 32
0m 0m
5m 4m 3m 2m 1m 0m 5m 4m 3m 2m 1m 0m

16 _ Wall Mounted (Libero)


7. Air Velocity and Temperature Distribution(Reference Data)
ARNU18GSC*2
Cooling Heating
Discharge angle : 10° Discharge angle : 30°

Air velocity [m/s] Air velocity [m/s]


2.7m 2.7m

2m 2m
2.0 2.0
1.5
1.5
1.0 1m
1m
1.0
0.5
0.5

0m 0m
5m 4m 3m 2m 1m 0m 5m 4m 3m 2m 1m 0m

Temperature [°C] Temperature [°C]


2.7m 2.7m

Indoor Units
10 2m 2m
44
12
42
14
40
1m 1m
32
18 16 38

34 36
0m 0m
5m 4m 3m 2m 1m 0m 5m 4m 3m 2m 1m 0m

ARNU24GSC*2
Cooling Heating
Discharge angle : 10° Discharge angle : 30°

Air velocity [m/s] Air velocity [m/s]


2.7m 2.7m

2m 2.5 2m

2.0 2.0
1.5
1.5
1m 1m
1.0
0.5 1.0
0.5
0.5

0m 0m
5m 4m 3m 2m 1m 0m 5m 4m 3m 2m 1m 0m

Temperature [°C] Temperature [°C]


2.7m 2.7m
32

2m 2m
10
18 12
34
14 44
1m 1m
35 42
16 36
36 38 34 32
38 40
0m 0m
5m 4m 3m 2m 1m 0m 5m 4m 3m 2m 1m 0m

Wall Mounted (Libero) _ 17


8. Electric Characteristics

Units Power supply IFM Input


Model Type Hz Volts Voltage range MCA MFA kW FLA Cooling Heating
ARNU05GSB*2 SB 0.20 15 0.02 0.16 21.0 21.0
ARNU07GSB*2 SB 0.20 15 0.02 0.16 21.0 21.0
ARNU09GSB*2 SB 0.20 15 0.02 0.16 21.0 21.0
Max: 264
ARNU12GSB*2 SB 50 220-240 0.20 15 0.02 0.16 21.0 21.0
Min:198
ARNU15GSB*2 SB 0.20 15 0.02 0.16 21.0 21.0
ARNU18GSC*2 SC 0.36 15 0.08 0.29 39.5 39.5
ARNU24GSC*2 SC 0.36 15 0.08 0.29 39.5 39.5
ARNU05GSB*2 SB 0.20 15 0.02 0.16 21.0 21.0
ARNU07GSB*2 SB 0.20 15 0.02 0.16 21.0 21.0
ARNU09GSB*2 SB 0.20 15 0.02 0.16 21.0 21.0
Max: 264
ARNU12GSB*2 SB 60 220 0.20 15 0.02 0.16 21.0 21.0
Min:198
ARNU15GSB*2 SB 0.20 15 0.02 0.16 21.0 21.0
ARNU18GSC*2 SC 0.36 15 0.08 0.29 39.5 39.5
Indoor Units

ARNU24GSC*2 SC 0.36 15 0.08 0.29 39.5 39.5

Symbols: Note :
MCA :Min, Circuit Amps(A) 1. Voltage range
Units are suitable for use on electrical systems
MFA:Max. Fuse Amps(see note 5)
where voltage supplied to unit terminals is not below
kW:Fan Motor Rated Output(kW) or above the listed range limits.
2. Maximum allowable voltage unbalance between
FLA:Full Load Amps(A)
phases is 2%
IFM:Indoor Fan Motor 3. MCA/MFA
MCA=1.25 x FLA
MFA≤ 4 x FLA
(Next lower standard fuse rating. Min. 15A)
4. Select wire size based on the MCA
5. Instead of fuse, use Circuit Breaker.

18 _ Wall Mounted (Libero)


9. Sound Levels
Overall
Notes:
1. Sound measured at each 1m away from the front and bottom of the unit
2. Operating condition
- Power source : 220-240V 50Hz / 220V 60Hz
- Cooling : Indoor temperature (27°C DB, 19°C WB),
1m Outdoor temperature (35°C DB, 24°C WB)
- Heating : Indoor temperature (20°C DB, 15°C WB),
1m Outdoor temperature (7°C DB, 6°C WB)
3. Reference accoustic pressure 0dB = 20μPa
4. Sound level will vary depending on a range of factors such as
Microphone the construction(acoustic absorption coefficient) of particular
❈ Measuring place : Anechoic chamber room in which the equipment in installed.
Sound Levels dB(A)
Model
H M L
ARNU05GSB*2 30 29 28
ARNU07GSB*2 32 30 28
ARNU09GSB*2 34 31 30
ARNU12GSB*2 40 34 31
ARNU15GSB*2 42 40 34

Indoor Units
ARNU18GSC*2 40 35 31
ARNU24GSC*2 45 40 35

Sound Pressure Level

ARNU05GSB*2 ARNU07GSB*2 ARNU09GSB*2


80 80 80
Octave Band Sound Pressure Level (0dB = 20μPa)

Octave Band Sound Pressure Level (0dB = 20μPa)

Octave Band Sound Pressure Level (0dB = 20μPa)

70 70 70

NC-65 NC-65 NC-65


60 60 60
NC-60 NC-60 NC-60

NC-55 NC-55 NC-55


50 50 50
NC-50 NC-50 NC-50

NC-45 NC-45 NC-45


40 40 40
NC-40 NC-40 NC-40

NC-35 NC-35 NC-35


30 30 30
NC-30 NC-30 NC-30

NC-25 NC-25 NC-25


20 20 20

Approximate NC-20 Approximate NC-20 Approximate NC-20


Hearing Hearing Hearing
Threshold NC-15 Threshold NC-15 Threshold
10 10 10
63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000

Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

Wall Mounted (Libero) _ 19


9. Sound Levels
ARNU12GSB*2 ARNU15GSB*2 ARNU18GSC*2
80 80 80
Octave Band Sound Pressure Level (0dB = 20μPa)

70

Octave Band Sound Pressure Level (0dB = 20μPa)

Octave Band Sound Pressure Level (0dB = 20μPa)


70 70

NC-65 NC-65 NC-65


60 60 60
NC-60 NC-60 NC-60

NC-55 NC-55 NC-55


50 50 50
NC-50 NC-50 NC-50

NC-45 NC-45 NC-45


40 40 40
NC-40 NC-40 NC-40

NC-35 NC-35 NC-35


30 30 30
NC-30 NC-30 NC-30

NC-25 NC-25 NC-25


20 20 20
Approximate NC-20 Approximate NC-20 Approximate NC-20
Hearing Hearing Hearing
Threshold Threshold NC-15 Threshold
10 10 10
63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)
Indoor Units

ARNU24GSC*2
80
Octave Band Sound Pressure Level (0dB = 20μPa)

70

NC-65
60
NC-60

NC-55
50
NC-50

NC-45
40
NC-40

NC-35
30
NC-30

NC-25
20
Approximate NC-20
Hearing
Threshold
10
63 125 250 500 1000 2000 4000 8000

Octave Band Center Frequency (Hz)

20 _ Wall Mounted (Libero)


10. Installation
• Please read this instruction sheet completely before installing the product.
• When the power cord is damaged, replacement work shall be performed by authorized personnel only.
• Installation work must be performed in accordance with the national wiring standards by authorized personnel only.

Installation Parts Provided

1. Installation Plate

2. Type “A” screws

Indoor Units
3. Type “B” screws

Required Parts Required Tools


o Installation plate o Level gauge
o Five type "A" screws o Screw driver
o Two type “B” screws o Electric drill
o Connecting cable o Hole core drill

o Pipes: Gas side


Liquid side
o Insulation materials
o Additional drain pipe o Flaring tool set
o Specified torque wrenches
o Spanner......................................................Half union

o A glass of water
o Screw driver

o Thermometer

Wall Mounted (Libero) _ 21


10. Installation
10.1 Selection of the best location
• There should not be any heat or steam near the unit.
More than
• Select a place where there are no obstacles around of the 100
unit. More than 200
• Make sure that condensation drainage can be conveniently
routed away.
• Do not install near a doorway. More than
• Ensure that the interval between a wall and the left (or right) of 100
the unit is more than 100mm. The unit should be installed as More than 2300
high as possible on the wall, allowing a minimum of 200mm
from ceiling.
• Use a metal detector to locate studs to prevent unnecessary
damage to the wall.

Fixing Installation Plate


The wall you select should be strong and solid enough to
Indoor Units

prevent vibration Installation Plate


• Mount the installation plate on the wall with type "A"
screws. If mounting the unit on a concrete wall, use
anchor bolts.
- Mount the installation plate horizontally by aligning the
centerline using Horizontal meter . Type "A" Screws

• Measure the wall and mark the centerline. It is also


important to use caution concerning the location of the
installation plate. Routing of the wiring to power outlets Chassis
is through the walls typically. Drilling the hole through Hook
the wall for piping connections must be done safely.

The lower left and the right side of Installation Plate

SB chassis SC chassis
Place a level on raised tab Place a level on raised tab
Unit Outline Unit Outline
442 442 460 570
Right rear piping
Left rear piping

Right rear piping

Ø65 Installation Plate


Ø65 Ø65
Installation Plate Ø65
Left rear piping

Measuring Tape
Ø65 Installation Plate
133 95 Ø65 69 56
175 217 105 207
Measuring Tape
Installation
Ø65 Hanger Plate
Ø65

CAUTION : In case that the unit is installed near the sea, the installation parts
may be corroded by salt. The installation parts (and the unit) should be taken
appropriate anti-corrosion measures.

22 _ Wall Mounted (Libero)


10. Installation
10.2 Connection of pipes and cables

10.2.1 Preparing work for installation


n Pull the screw cap at the bottom of the indoor unit
n Remove the chassis cover from the unit by loosing 2
screws

Indoor Units
Chassis cover
Bad case
n Pull back the tubing holder. 1. Following bending case from right to left direct-
n Remove pipe port cover and positioning the tubing ly may cause damage to the tubing.

Indoor unit back side view Tubing holder

Right Left
Downwards Backwards

h The feature can be changed according to type of


model.

Good case
h The feature can be changed according to type of model.
1. Press on the tubing cover and unfold the tub-
ing to downward slowly. And then bend to CAUTION
the left side slowly.
Installation Information. For right piping. Follow the
instruction above.

Wall Mounted (Libero) _ 23


10. Installation
10.2.2 Installation of Indoor Unit Open-end wrench
(fixed)
1. Hook the indoor unit onto the upper portion of
the installation plate.( engage the three hooks at Flare nut
the top of the indoor unit with the upper edge of
the installation plate) Ensure that the hooks are Wrench Connection
pipe
properly seated on the installation plate by mov-
ing it left and right Indoor unit tubing

1 3. When needed to extend the drain hose of indoor


unit, assembly the drain pipe as shown on the
drawing

2 Installation plate

Drain pipe
2. Unlock the tubing holder from the chassis and
Indoor Units

mount between the chassis and installation


plate in order to separate the bottom side of the
indoor unit from the wall. Indoor unit drain hose

Adhesive Vinyl tape(narrow)

Connecting the cables


Tubing Holder

1. Insert the connecting cable through the bottom


* The feature can be changed according to type of
side of indoor unit and connect the cable (You
model.
can see detail contents in 'Connecting the
cables' section)

Connecting the installation pipe


and drain hose to the indoor unit.

1. Align the center of the pipes and sufficiently View


tighten the flare nut by hand

Terminal block of indoor unit


1(L) 2(N) 3(A) 4(B)

Indoor unit tubing Flare nut Pipes


Indoor power input Outdoor unit

2. Tighten the flare nut with a wrench


2. Secure the cable onto the control board with the
cable retainer.

24 _ Wall Mounted (Libero)


10. Installation
Wrap the insulation material
Wrap with vinyl tape
around the connecting portion.
Pipe
1. Overlap the connection pipe insulation material
and the indoor unit pipe insulation material.
Bind them together with vinyl tape so that there Vinyl tape(wide)
may be no gap. Drain hose

Insulation material
CAUTION
If the drain hose is routed inside the room insulate
the hose with an insulation material* so that dripping
from sweating condensation) will not damage furni-
ture or floors.
2. Set the tubing cutting line upward. * Foamed polyethylene or equivalent is

Indoor Units
Wrap the area which accommodates the rear recommended.
piping housing section with vinyl tape.

Cutting Line

Cutting Line
Gas Pipe Liquid Pipe
Good Case Bad Case
* Tubing cutting line have to be upward.

Connection pipe Indoor unit pipe


Vinyl tape (wide) Wrap with vinyl tape

Connecting cable

Pipe
Vinyl tape(narrow)

3. Bundle the piping and drain hose together by


wrapping them with vinyl tape sufficient enough
to cover where they fit into the rear piping hous-
ing section. Be sure that the drain hose is locat-
ed at the lowest side of the bundle. Locating at
the upper side can cause overflow from the
drain pan through the inside of the unit.

Wall Mounted (Libero) _ 25


10. Installation
10.2.3 Finishing the indoor unit instal- Drain piping
lation
1. The drain hose should point downward for easy
1. Mount the tubing holder in the original positon. drain flow.
2. Ensure that the hooks are properly seated on
the installation plate by moving it left and right. Downward slope
3. Press the lower left and right sides of the unit
against the installation plate until the hooks
engage into their slots (clicking sound).
4. Finish the assembly by screwing the unit to the
installation plate by using two pieces of type
"C" screws. And assemble a chassis cover.
2. Do not make drain piping like the following.

Do not raise
Indoor Units

Water
leakage
Accumulated
drain water
Air

Type 'C' screw Water


Waving
leakage

10.2.4 Checking the Drainage Tip of drain hose


dipped in water

To check the drainage.


Water
leakage Ditch
1. Pour a glass of water on the evaporator.
2. Ensure the water flows through the drain hose
of the indoor unit without any leakage and goes Less than
out the drain exit. 50mm gap

Connecting area
drain hose

* The feature can be changed according to type of


Leakage model.
checking

Drain pan

Drain
hose
Leakage
checking

26 _ Wall Mounted (Libero)


10. Installation
10.3 Wiring the cable to the indoor units
[Indoor Unit side] [Outdoor Unit side]
[Type 1]

Terminal Block Indoor SODU B SODU A IDU B IDU A INT B INT A


1(L) 2(N) 3 4

INDOOR POWER INPUT


[Type 2]
Terminal Block Indoor SODU IDU INTERNET DRY1 DRY2 GND 12V
1(L) 2(N) 3 4 B A - - B A - - - -

INDOOR POWER INPUT


[Type 3]
Terminal block of outdoor unit

Indoor Units
Terminal Block Indoor Central controller Indoor unit Outdoor unit
1(L) 2(N) 3 4 12V GND DRY2 DRY1 CEN CEN IDU IDU SODU SODU

INDOOR POWER INPUT

WARNING
Make sure that the screws of the terminal are free from looseness.

CAUTION
The Power cord connected to the unit should be selected according to the following specifications.

CAUTION
After the confirmation of the above conditions, prepare the wiring as follows:
1) Never fail to have separate power specially for the air conditioner. As for the method of wiring, follow the
circuit diagram pasted on the inside of control box cover.
2) Provide a circuit breaker switch between power source and the unit.
3) The screw which fasten the wiring in the casing of electrical fittings are liable to come loose from vibra-
tions to which the unit is subjected during the course of transportation. Check them and make sure that
they are all tightly fastened. (If they are loose, it could give rise to burn-out of the wires.)
4) Confirm the Specification of power source
5) Confirm that electrical capacity is sufficient.
6) Be sure that the starting voltage is maintained at more than 90 percent of the rated voltage marked on
the name plate.
7) Confirm that the cable thickness is as specified in the power sources specification.
(Particularly note the relation between cable length and thickness.)
8) Do not install the leakage breaker in a place which is wet or moist.
Water or moist may cause short circuit.
9) The following troubles would be caused by voltage drop-down.
- Vibration of a magnetic switch, damage on the contact point there of, fuse breaking, disturbance to the
normal function of a overload protection device.
- Proper starting power is not given to the compressor.

Wall Mounted (Libero) _ 27


10. Installation

WIRED REMOTE CONTROLLER INSTALLATION


• Since the room temperature sensor is in the remote controller, the remote controller box should be installed in a place away
from direct sunlight, high humidity and direct supply of cold air to maintain proper space temperature.
Install the remote controller about 5ft(1.5m) above the floor in an area with good air circulation at an average temperature.
Do not install the remote controller where it can be affected by:
- Drafts, or dead spots behind doors and in corners.
- Hot or cold air from ducts.
- Radiant heat from sun or appliances.
- Concealed pipes and chimneys.
- Uncontrolled areas such as an outside wall behind the remote controller.
- This remote controller is equipped with a seven segment LED. display. For proper display of the remote controller
LED's, the remote controller should be installed properly as shown in Fig.1.
(The standard height is 1.2~1.5 m from floor level.)
Indoor Units

Remote Controller
TEMP
yes

no
TEMP

Remote Controller

no
TEMP
5feet
Remote
Controller

(1.5meters)

no

Fig.1 Typical locations for remote controller

28 _ Wall Mounted (Libero)


11. Accessories
Standard Accessories

Type "A" screws and


Name Installation panel Type “C” screws (Other)
plastic anchors

Quantity 1 set 5 set 2 set

SB/SC

• Owner's manual
Shape • Installation manual

Indoor Units

Wall Mounted (Libero) _ 29


Indoor unit

ART COOL Mirror


1. List of functions

2. Specifications

3. Dimensions

4. Piping Diagrams

5. Wiring Diagrams

6. Capacity Tables

7. Air Velocity and Temperature Distribution

8. Electric Characteristics

9. Sound Levels

10. Installation

11. Accessories
1. List of functions

ARNU07GSE*2, ARNU09GSE*2, ARNU12GSE*2


Category Function
ARNU15GSE*2, ARNU18GS8*2, ARNU24GS8*2
Air supply outlet 1
Airflow direction control(left & right) Auto
Airflow direction control(up & down) Auto
Auto swing(left & right) Auto
Auto swing(up & down) X
Air flow
Airflow steps(fan/cool/heat) 3/4/3
Chaos swing O
Chaos wind(auto wind) O
Jet cool(Power wind) O
Swirl wind -
Deodorizing filter X
Air purifying Plasma air purifier O
Prefilter(washable / anti-fungus) O
Drain pump -
E.S.P. control -
Installation

Indoor Units
Electric heater(operation) -
High ceiling operation -
Hot start O
Reliability Self diagnosis O
Soft dry operation O
Auto changeover O(Heat recovery)
Auto cleaning O
Auto operation(artificial intelligence) O(Heat pump or Cooling only)
Auto restart operation O
Child lock O
Convenience Forced operation O
Group control O
Sleep mode O
Timer(on/off) O
Timer(weekly) O
Two thermistor control O
Wide wired remote controller PQRCVSL0/PQRCVSL0QW
Deluxe wired remote controller X
Individual
Simple wired remote controller PQRCVCL0Q(W)
control
Wired remote controller(for hotel use) PQRCHCA0Q(W)
Wireless LCD remote control PQWRH(C)Q0FDB
Zone control -
CTIE -
Special Electro thermostat -
function kit Remote temperature sensor -
Group control wire PZCWRCG3
Dry contact PQDSA(1)/PQDSB(1)/PQDSBC/PQDSBNGCM1/PQDSBCGCD0

O : Applied X : Not applied – : No relation


Option : Model name & price are different according to options, and assembled in factory with main unit.
Accessory : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate
package.

ART COOL Mirror _ 1


2. Specifications
Type ART COOL Mirror
Model Unit
ARNU07GSE*2 ARNU09GSE*2 ARNU12GSE*2
kW 2.2 2.8 3.6
Cooling Capacity kcal/h 1,900 2,400 3,100
Btu/h 7,500 9,600 12,300
kW 2.5 3.2 4.0
Heating Capacity kcal/h 2,200 2,800 3,400
Btu/h 8,500 10,900 13,600
915 mm x 282 x 165 915 x 282 x 165 915 x 282 x 165
Dimensions(WxHxD) Body
inch
36-1/32 x 11-3/32 x 6-1/2 36-1/32 x 11-3/32 x 6-1/2 36-1/32 x 11-3/32 x 6-1/2
Coil Rows x Columns x FPI 2 x 15 x 18 2 x 15 x 18 2 x 15 x 18
Face Area m2 0.21 0.21 0.21
Type Cross Flow Fan Cross Flow Fan Cross Flow Fan
Motor Output x Number W 20 20 20
Running Current A 0.2 0.2 0.2
Fan Air Flow Rate(H / M / L) CMM 7.0 / 6.0 / 4.0 8.0 / 7.0 / 5.0 10.0 / 8.0 / 6.0
cfm 247 / 212 / 141 282 / 247 / 177 353 / 283 / 212
Indoor Units

Drive Direct Direct Direct


Motor type BLDC BLDC BLDC
Temperature Control Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating
Sound Absorbing Thermal Insulation Material Foamed polystrene Foamed polystrene Foamed polystrene
Air Filter Resin Net(washable) Resin Net(washable) Resin Net(washable)
Safety Device Fuse Fuse Fuse
Liquid Side mm(inch) Ø6.35(1/4) Ø6.35(1/4) Ø6.35(1/4)
Pipe Connections Gas Side mm(inch) Ø12.7(1/2) Ø12.7(1/2) Ø12.7(1/2)
Drain Pipe(Internal Dia.) mm(inch) 16(5/8) 16(5/8) 16(5/8)
Net Weight kg(lbs) 11.2(24.7) 11.2(24.7) 11.2(24.7)
Noise Level(Sound Press, 1m, H / M / L) dB(A) 37 / 33 / 23 39 / 35 / 25 41 / 36 / 27
Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50
1, 220, 60 1, 220, 60 1, 220, 60
Refrigerant Control EEV EEV EEV
Power cable mm2 CV1.5 x 3C CV1.5 x 3C CV1.5 x 3C
Transmission cable mm2 CVV-SB 1.0~1.5 x 2C CVV-SB 1.0~1.5 x 2C CVV-SB 1.0~1.5 x 2C
Front Panel('*' Position) R:Mirror V:Silver

Notes:-
Conversion Formula
1. Capacities are based on the following conditions:
Cooling • Indoor temp. 27°C[80.6°F]DB/ 19°C[66.2°F]WB kcal/h= kW x 860
• Outdoor temp. 35°C[95°F]DB/ 24°C[75.2°F]WB Btu/h = kW x 3412
• Interconnecting Piping Length 7.5m cfm = m3/min x 35.3
• Level Difference of Zero l/s = CMM x 1000/60
Heating • Indoor temp. 20°C[68°F]DB/ 15°C[59°F]WB
• Outdoor temp. 7°C[44.6°F]DB/ 6°C[42.8°F]WB
• Interconnecting Piping Length 7.5m
• Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve
6. Anechoic chamber conversion value is measured at 1 m downward from unit centre.
The values depends on the ambient conditions and values are normally higher in actual operation.

2 _ ART COOL Mirror


2. Specifications

Type ART COOL Mirror


Model Unit
ARNU15GSE*2 ARNU18GS8*2 ARNU24GS8*2
kW 4.5 5.6 7.1
Cooling Capacity kcal/h 3,900 4,800 6,100
Btu/h 15,400 19,100 24,200
kW 5.0 6.3 8.0
Heating Capacity kcal/h 4,300 5,400 6,900
Btu/h 17,100 21,500 27,300
915 mm x 282 x 165 1,107 x 299 x 200 1,107 x 299 x 200
Dimensions(WxHxD) Body
inch
36-1/32 x 11-3/32 x 6-1/2 43-19/32 x 11-25/32 x 7-7/8 43-19/32 x 11-25/32 x 7-7/8
Coil Rows x Columns x FPI 2 x 15 x 18 2 x 15 x 20 2 x 15 x 20
Face Area m2 0.21 0.26 0.26
Type Cross Flow Fan Cross Flow Fan Cross Flow Fan
Motor Output x Number W 20 20 20
Running Current A 0.2 0.2 0.2
Fan Air Flow Rate(H / M / L) CMM 10.5 / 8.0 / 6.0 14.4 / 13.0 / 11.0 17.9 / 14.4 / 12.0

Indoor Units
cfm 371 / 283 / 212 508 / 459 / 388 632 / 508 / 424
Drive Direct Direct Direct
Motor type BLDC BLDC BLDC
Temperature Control Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating
Sound Absorbing Thermal Insulation Material Foamed polystrene Foamed polystrene Foamed polystrene
Air Filter Resin Net(washable) Resin Net(washable) Resin Net(washable)
Safety Device Fuse Fuse Fuse
Liquid Side mm(inch) Ø6.35(1/4) Ø6.35(1/4) Ø9.52(3/8)
Pipe Connections Gas Side mm(inch) Ø12.7(1/2) Ø12.7(1/2) Ø15.88(5/8)
Drain Pipe(Internal Dia.) mm(inch) 16(5/8) 16(5/8) 16(5/8)
Net Weight kg(lbs) 11.2(24.7) 15(33.1) 15(33.1)
Noise Level(Sound Press, 1m, H / M / L) dB(A) 42 / 36 / 27 37 / 34 / 31 43 / 37 / 32
Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50
1, 220, 60 1, 220, 60 1, 220, 60
Refrigerant Control EEV EEV EEV
Power cable mm2 CV1.5 x 3C CV1.5 x 3C CV1.5 x 3C
Transmission cable mm2 CVV-SB 1.0~1.5 x 2C CVV-SB 1.0~1.5 x 2C CVV-SB 1.0~1.5 x 2C
Front Panel('*' Position) R:Mirror V:Silver

Notes:- Conversion Formula


1. Capacities are based on the following conditions:
kcal/h= kW x 860
Cooling • Indoor temp. 27°C[80.6°F]DB/ 19°C[66.2°F]WB
Btu/h = kW x 3412
• Outdoor temp. 35°C[95°F]DB/ 24°C[75.2°F]WB
cfm = m3/min x 35.3
• Interconnecting Piping Length 7.5m
l/s = CMM x 1000/60
• Level Difference of Zero
Heating • Indoor temp. 20°C[68°F]DB/ 15°C[59°F]WB
• Outdoor temp. 7°C[44.6°F]DB/ 6°C[42.8°F]WB
• Interconnecting Piping Length 7.5m
• Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve
6. Anechoic chamber conversion value is measured at 1 m downward from unit centre.
The values depends on the ambient conditions and values are normally higher in actual operation.

ART COOL Mirror _ 3


Indoor Units

ART COOL Mirror


H
ARNU07GSE*2
2 ARNU09GSE*2
ARNU12GSE*2
ARNU15GSE*2

4 _ ART COOL Mirror


D
3. Dimensions

W
(unit : mm)
Model W H D

165
1
ARNU07GSE*2
165 ARNU09GSE*2 915 282 165
ARNU12GSE*2
ARNU15GSE*2

(unit : mm)
Number Name Descripition

282

282
1 Air discharge grill

53
2 Air suction grill
915 51

567
Note
1. Unit should be installed in compliance with the installation manual
in the product box.
2. Unit shall be grounded in accordance with the local regulations or
applicable national codes.
265

76, Seongsan-dong, Changwon City, Gyeongnam,


641-713, Korea CHASSIS CODE: SE
ART COOL Mirror
3 ARNU18GS8*2
ARNU24GS8*2

1
3. Dimensions

(unit : mm)
No. Part Name Remark

299
4 1 Front panel

10
63
2 2 Display & signal receiver
53 Air suction grille
1107 3
200
4 Knockout hole
5 Installation plate

93

48
72
58 122

804

Note
1. Unit should be installed in compliance with the installation manual

281
in the product box.
2. Unit shall be grounded in accordance with the local regulations or
applicable national codes.

76, Seongsan-dong, Changwon City, Gyeongnam,


641-713, Korea CHASSIS CODE: S8

ART COOL Mirror _ 5


Indoor Units
4. Piping Diagrams

:Cooling
Heat Exchanger EEV :Heating
Filter

Th3 Th2
C.F.F Filter

Th1 lndoor unit


Indoor Units

Refrigerant pipe connection port diameter

[Unit: mm(inch)]
MODEL GAS LIQUID

ARNU07GSE*2 Ø12.7(1/2) Ø6.35(1/4)

ARNU09GSE*2 Ø12.7(1/2) Ø6.35(1/4)

ARNU12GSE*2 Ø12.7(1/2) Ø6.35(1/4)

ARNU15GSE*2 Ø12.7(1/2) Ø6.35(1/4)

ARNU18GS8*2 Ø12.7(1/2) Ø6.35(1/4)

ARNU24GS8*2 Ø15.88(5/8) Ø9.52(3/8)

*Panel Color (SE/S8 chassis) : R(Mirror),V(Silver)

LOC. Description PCB Connector


Th1 Room thermistor
CN-TH1
Th2 Pipe in thermistor
Th3 Pipe out thermistor CN-TH2

6 _ ART COOL Mirror


5. Wiring Diagrams
SE/S8 Chassis

Indoor Units
CONNECTOR NUMBER LOCATION POINT FUNCTION
CN-MOTOR1 Fan motor output Motor output of BLDC
CN-COM Communication Communication between indoor and outdoor
CN-EEV EEV output EEV control output
CN-L/R Step motor Step motor output for left/right
CN-U/D Step motor Step motor output
CN-TH1 Room/pipe sensor Room & pipe thermistor
CN-TH2 Discharge pipe sensor Discharge pipe thermistor
CN-SUC Step motor(front) Front panel step motor
CN-HVB Air purifier Air purifier output
CN-VFD Display Display of indoor status
CN-12V Safety connection Safety of indoor status
CN-REMO Remote controller Remote control line
CN-CC Dry contact Dry contact line
CN-HVB Air clean Air clean control

ART COOL Mirror _ 7


6. Capacity Tables
6.1 Cooling Capacity
Cooling Capacity

Indoor air temp. (DB/WB, °C)


Capacity Outdoor 20 23 26 27 28 30 32
Index air temp. 14 16 18 19 20 22 24
(DB, °C) TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.9 1.7
12 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.9 1.6
14 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.8 1.6
16 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.8 1.6
18 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.7 1.6
20 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.7 1.6
21 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.7 1.5
23 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.6 1.5
2.2 25 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.6 1.5
27 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.5 1.6 2.6 1.5
29 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.5 1.6 2.5 1.5
Indoor Units

31 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.5 1.6 2.5 1.4
33 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.4 1.5 2.5 1.4
35 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.4 1.5 2.4 1.4
37 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.3 1.5 2.4 1.4
39 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.2 1.5 2.3 1.5 2.3 1.4
10 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.7 2.1
12 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.6 2.1
14 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.6 2.1
16 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.5 2.0
18 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.5 2.0
20 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.4 2.0
21 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.4 2.0
23 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.4 1.9
2.8 25 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.3 2.1 3.3 1.9
27 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.2 2.1 3.3 1.9
29 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.2 2.0 3.2 1.9
31 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.1 2.0 3.2 1.8
33 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.1 2.0 3.1 1.8
35 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.0 1.9 3.1 1.8
37 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 2.9 2.0 3.0 1.9 3.0 1.8
39 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 2.9 2.0 2.9 1.9 3.0 1.7
10 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.7 2.8
12 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.7 2.7
14 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.6 2.7
16 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.6 2.7
18 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.5 2.6
20 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.4 2.6
21 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.4 2.6
23 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.3 2.5
3.6 25 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.2 2.8 4.3 2.5
27 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.1 2.7 4.2 2.5
29 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.1 2.7 4.2 2.4
31 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.0 2.6 4.1 2.4
33 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.0 2.6 4.0 2.4
35 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 3.9 2.5 4.0 2.3
37 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.7 2.6 3.8 2.5 3.9 2.3
39 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.7 2.6 3.7 2.4 3.8 2.2

8 _ ART COOL Mirror


6. Capacity Tables
Cooling Capacity

Indoor air temp. (DB/WB, °C)


Capacity Outdoor 20 23 26 27 28 30 32
Index air temp. 14 16 18 19 20 22 24
(DB, °C) TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10 3.0 2.6 3.6 2.9 4.2 3.1 4.5 3.2 4.8 3.3 5.4 3.5 5.9 3.4
12 3.0 2.6 3.6 2.9 4.2 3.1 4.5 3.2 4.8 3.3 5.4 3.5 5.8 3.4
14 3.0 2.6 3.6 2.9 4.2 3.1 4.5 3.2 4.8 3.3 5.4 3.5 5.8 3.3
16 3.0 2.6 3.6 2.9 4.2 3.1 4.5 3.2 4.8 3.3 5.4 3.5 5.7 3.3
18 3.0 2.6 3.6 2.9 4.2 3.1 4.5 3.2 4.8 3.3 5.4 3.5 5.6 3.3
20 3.0 2.6 3.6 2.9 4.2 3.1 4.5 3.2 4.8 3.3 5.4 3.5 5.5 3.2
21 3.0 2.6 3.6 2.9 4.2 3.1 4.5 3.2 4.8 3.3 5.4 3.5 5.5 3.2
23 3.0 2.6 3.6 2.9 4.2 3.1 4.5 3.2 4.8 3.3 5.4 3.5 5.4 3.1
4.5 25 3.0 2.6 3.6 2.9 4.2 3.1 4.5 3.2 4.8 3.3 5.3 3.4 5.3 3.1
27 3.0 2.6 3.6 2.9 4.2 3.1 4.5 3.2 4.8 3.3 5.2 3.3 5.3 3.1
29 3.0 2.6 3.6 2.9 4.2 3.1 4.5 3.2 4.8 3.3 5.1 3.3 5.2 3.0

Indoor Units
31 3.0 2.6 3.6 2.9 4.2 3.1 4.5 3.2 4.8 3.3 5.1 3.2 5.1 2.9
33 3.0 2.6 3.6 2.9 4.2 3.1 4.5 3.2 4.8 3.3 4.9 3.2 5.0 2.9
35 3.0 2.6 3.6 2.9 4.2 3.1 4.5 3.2 4.8 3.3 4.9 3.1 4.9 2.9
37 3.0 2.6 3.6 2.9 4.2 3.1 4.5 3.2 4.7 3.2 4.8 3.1 4.9 2.8
39 3.0 2.6 3.6 2.9 4.2 3.1 4.5 3.2 4.6 3.1 4.7 3.0 4.8 2.8
10 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.7 4.3 7.4 4.3
12 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.7 4.3 7.3 4.2
14 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.7 4.3 7.2 4.2
16 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.7 4.3 7.1 4.1
18 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.7 4.3 7.0 4.1
20 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.7 4.3 6.9 4.0
21 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.7 4.3 6.8 4.0
23 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.7 4.3 6.7 3.9
5.6 25 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.6 4.3 6.6 3.9
27 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.4 4.2 6.6 3.8
29 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.4 4.1 6.5 3.8
31 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.3 4.1 6.4 3.7
33 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.2 4.0 6.3 3.7
35 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.0 3.9 6.2 3.6
37 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 5.8 4.1 5.9 3.8 6.1 3.6
39 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 5.7 4.0 5.8 3.8 6.0 3.5
10 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 8.5 5.6 9.3 5.5
12 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 8.5 5.6 9.2 5.5
14 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 8.5 5.6 9.1 5.4
16 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 8.5 5.6 9.0 5.3
18 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 8.5 5.6 8.8 5.2
20 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 8.5 5.6 8.7 5.2
21 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 8.5 5.6 8.7 5.1
23 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 8.5 5.6 8.5 5.1
7.1 25 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 8.4 5.5 8.4 5.0
27 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 8.2 5.4 8.3 4.9
29 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 8.1 5.3 8.2 4.8
31 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 8.0 5.2 8.1 4.8
33 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 7.8 5.1 7.9 4.7
35 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.6 5.3 7.7 5.0 7.8 4.6
37 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.4 5.2 7.5 4.9 7.7 4.6
39 4.8 4.3 5.7 4.7 6.6 5.1 7.1 5.2 7.2 5.1 7.4 4.8 7.6 4.5

Notes:
TC: Total Capacity(kW), SHC: Sensible Heat Capacity(kW) 2. Refer to Capacity Correction Factor in the outdoor unit PDB for
1. Capacity tables show the representative value of conditions the actual performance data of each indoor unit and outdoor unit
which may occur. combination.

ART COOL Mirror _ 9


6. Capacity Tables
6.2 Heating Capacity Heating Capacity

Outdoor air Indoor air temp. (DB, °C)


Capacity temp. 16 18 20 21 22 24
Index TC TC TC TC TC TC
DB(°C) WB(°C)
kW kW kW kW kW kW
-24.8 -25.0 1.4 1.4 1.4 1.4 1.4 1.4
-21.8 -22.0 1.7 1.7 1.7 1.7 1.7 1.7
-19.8 -20.0 1.8 1.8 1.8 1.8 1.8 1.8
-18.8 -19.0 1.9 1.9 1.9 1.9 1.9 1.9
-16.7 -17.0 2.0 2.0 2.0 2.0 2.0 2.0
-14.7 -15.0 2.1 2.1 2.1 2.1 2.1 2.0
-12.6 -13.0 2.2 2.2 2.2 2.2 2.1 2.1
-10.5 -11.0 2.3 2.3 2.2 2.2 2.2 2.2
-9.5 -10.0 2.3 2.3 2.3 2.3 2.3 2.2
-8.5 -9.1 2.3 2.3 2.3 2.3 2.3 2.2
-7.0 -7.6 2.4 2.4 2.4 2.4 2.3 2.2
2.2 -5.0 -5.6 2.5 2.5 2.5 2.4 2.3 2.2
-3.0 -3.7 2.6 2.6 2.5 2.4 2.3 2.2
0.0 -0.7 2.7 2.6 2.5 2.4 2.3 2.2
Indoor Units

3.0 2.2 2.7 2.7 2.5 2.4 2.3 2.2


5.0 4.1 2.8 2.7 2.5 2.4 2.3 2.2
7.0 6.0 2.8 2.7 2.5 2.4 2.3 2.2
9.0 7.9 2.8 2.7 2.5 2.4 2.3 2.2
11.0 9.8 2.8 2.7 2.5 2.4 2.3 2.2
13.0 11.8 2.8 2.7 2.5 2.4 2.3 2.2
15.0 13.7 2.8 2.7 2.5 2.4 2.3 2.2
-24.8 -25.0 1.9 1.9 1.8 1.8 1.8 1.8
-21.8 -22.0 2.2 2.2 2.2 2.2 2.2 2.2
-19.8 -20.0 2.4 2.4 2.3 2.3 2.3 2.3
-18.8 -19.0 2.4 2.4 2.4 2.4 2.4 2.4
-16.7 -17.0 2.5 2.5 2.5 2.5 2.5 2.5
-14.7 -15.0 2.7 2.7 2.6 2.6 2.6 2.6
-12.6 -13.0 2.8 2.8 2.8 2.8 2.7 2.7
-10.5 -11.0 2.9 2.9 2.9 2.9 2.9 2.8
-9.5 -10.0 3.0 3.0 2.9 2.9 2.9 2.8
-8.5 -9.1 3.0 3.0 3.0 3.0 3.0 2.8
2.8 -7.0 -7.6 3.1 3.1 3.1 3.1 3.0 2.8
-5.0 -5.6 3.2 3.2 3.2 3.1 3.0 2.8
-3.0 -3.7 3.4 3.3 3.2 3.1 3.0 2.8
0.0 -0.7 3.4 3.3 3.2 3.1 3.0 2.8
3.0 2.2 3.5 3.4 3.2 3.1 3.0 2.8
5.0 4.1 3.6 3.4 3.2 3.1 3.0 2.8
7.0 6.0 3.6 3.4 3.2 3.1 3.0 2.8
9.0 7.9 3.6 3.4 3.2 3.1 3.0 2.8
11.0 9.8 3.6 3.4 3.2 3.1 3.0 2.8
13.0 11.8 3.6 3.4 3.2 3.1 3.0 2.8
15.0 13.7 3.6 3.4 3.2 3.1 3.0 2.8
-24.8 -25.0 2.3 2.3 2.3 2.3 2.3 2.3
-21.8 -22.0 2.8 2.8 2.8 2.8 2.8 2.8
-19.8 -20.0 2.9 2.9 2.9 2.9 2.9 2.9
-18.8 -19.0 3.0 3.0 3.0 3.0 3.0 3.0
-16.7 -17.0 3.1 3.1 3.1 3.1 3.1 3.1
-14.7 -15.0 3.3 3.3 3.3 3.3 3.3 3.3
-12.6 -13.0 3.5 3.4 3.4 3.4 3.4 3.4
-10.5 -11.0 3.6 3.6 3.6 3.6 3.6 3.5
-9.5 -10.0 3.7 3.7 3.7 3.7 3.7 3.5
-8.5 -9.1 3.8 3.8 3.7 3.7 3.7 3.5
-7.0 -7.6 3.9 3.9 3.9 3.8 3.7 3.5
3.6 -5.0 -5.6 4.0 4.0 4.0 3.9 3.7 3.5
-3.0 -3.7 4.2 4.1 4.0 3.9 3.7 3.5
0.0 -0.7 4.3 4.1 4.0 3.9 3.7 3.5
3.0 2.2 4.4 4.3 4.0 3.9 3.7 3.5
5.0 4.1 4.5 4.3 4.0 3.9 3.7 3.5
7.0 6.0 4.5 4.3 4.0 3.9 3.7 3.5
9.0 7.9 4.5 4.3 4.0 3.9 3.7 3.5
11.0 9.8 4.5 4.3 4.0 3.9 3.7 3.5
13.0 11.8 4.5 4.3 4.0 3.9 3.7 3.5
15.0 13.7 4.5 4.3 4.0 3.9 3.7 3.5

10 _ ART COOL Mirror


6. Capacity Tables
Heating capacity

Outdoor air Indoor air temp. (DB, °C)


Capacity temp. 16 18 20 21 22 24
Index TC TC TC TC TC TC
DB(°C) WB(°C)
kW kW kW kW kW kW
-24.8 -25.0 2.9 2.9 2.9 2.9 2.9 2.9
-21.8 -22.0 3.5 3.5 3.5 3.5 3.5 3.5
-19.8 -20.0 3.7 3.7 3.7 3.7 3.7 3.6
-18.8 -19.0 3.8 3.7 3.7 3.7 3.7 3.7
-16.7 -17.0 3.9 3.9 3.9 3.9 3.9 3.9
-14.7 -15.0 4.1 4.1 4.1 4.1 4.1 4.1
-12.6 -13.0 4.3 4.3 4.3 4.3 4.3 4.3
-10.5 -11.0 4.5 4.5 4.5 4.5 4.5 4.4
-9.5 -10.0 4.6 4.6 4.6 4.6 4.6 4.4
-8.5 -9.1 4.7 4.7 4.7 4.7 4.7 4.4
-7.0 -7.6 4.8 4.8 4.8 4.8 4.7 4.4
4.5 -5.0 -5.6 5.0 5.0 5.0 4.8 4.7 4.4
-3.0 -3.7 5.3 5.1 5.0 4.8 4.7 4.4
0.0 -0.7 5.3 5.2 5.0 4.8 4.7 4.4
3.0 2.2 5.5 5.3 5.0 4.8 4.7 4.4
5.0 4.1 5.6 5.3 5.0 4.8 4.7 4.4

Indoor Units
7.0 6.0 5.6 5.3 5.0 4.8 4.7 4.4
9.0 7.9 5.6 5.3 5.0 4.8 4.7 4.4
11.0 9.8 5.6 5.3 5.0 4.8 4.7 4.4
13.0 11.8 5.6 5.3 5.0 4.8 4.7 4.4
15.0 13.7 5.6 5.3 5.0 4.8 4.7 4.4
-24.8 -25.0 3.6 3.6 3.6 3.6 3.6 3.6
-21.8 -22.0 4.4 4.4 4.4 4.4 4.4 4.4
-19.8 -20.0 4.6 4.6 4.6 4.6 4.6 4.6
-18.8 -19.0 4.8 4.7 4.7 4.7 4.7 4.7
-16.7 -17.0 5.0 5.0 5.0 4.9 4.9 4.9
-14.7 -15.0 5.2 5.2 5.2 5.2 5.2 5.2
-12.6 -13.0 5.5 5.4 5.4 5.4 5.4 5.4
-10.5 -11.0 5.7 5.7 5.7 5.7 5.7 5.5
-9.5 -10.0 5.8 5.8 5.8 5.8 5.8 5.5
-8.5 -9.1 5.9 5.9 5.9 5.9 5.9 5.5
5.6 -7.0 -7.6 6.1 6.1 6.1 6.0 5.9 5.5
-5.0 -5.6 6.3 6.3 6.3 6.1 5.9 5.5
-3.0 -3.7 6.6 6.5 6.3 6.1 5.9 5.5
0.0 -0.7 6.7 6.5 6.3 6.1 5.9 5.5
3.0 2.2 6.9 6.7 6.3 6.1 5.9 5.5
5.0 4.1 7.0 6.7 6.3 6.1 5.9 5.5
7.0 6.0 7.1 6.7 6.3 6.1 5.9 5.5
9.0 7.9 7.1 6.7 6.3 6.1 5.9 5.5
11.0 9.8 7.1 6.7 6.3 6.1 5.9 5.5
13.0 11.8 7.1 6.7 6.3 6.1 5.9 5.5
15.0 13.7 7.1 6.7 6.3 6.1 5.9 5.5
-24.8 -25.0 4.6 4.6 4.6 4.6 4.6 4.6
-21.8 -22.0 5.6 5.6 5.6 5.6 5.6 5.5
-19.8 -20.0 5.9 5.9 5.9 5.9 5.9 5.8
-18.8 -19.0 6.0 6.0 6.0 6.0 6.0 6.0
-16.7 -17.0 6.3 6.3 6.3 6.3 6.3 6.3
-14.7 -15.0 6.6 6.6 6.6 6.6 6.6 6.6
-12.6 -13.0 6.9 6.9 6.9 6.9 6.9 6.9
-10.5 -11.0 7.2 7.2 7.2 7.2 7.2 7.0
-9.5 -10.0 7.4 7.4 7.3 7.3 7.3 7.0
-8.5 -9.1 7.5 7.5 7.5 7.5 7.5 7.0
-7.0 -7.6 7.7 7.7 7.7 7.7 7.5 7.0
7.1 -5.0 -5.6 8.0 8.0 8.0 7.7 7.5 7.0
-3.0 -3.7 8.4 8.2 8.0 7.7 7.5 7.0
0.0 -0.7 8.6 8.3 8.0 7.7 7.5 7.0
3.0 2.2 8.8 8.5 8.0 7.7 7.5 7.0
5.0 4.1 8.9 8.5 8.0 7.7 7.5 7.0
7.0 6.0 9.0 8.5 8.0 7.7 7.5 7.0
9.0 7.9 9.0 8.5 8.0 7.7 7.5 7.0
11.0 9.8 9.0 8.5 8.0 7.7 7.5 7.0
13.0 11.8 9.0 8.5 8.0 7.7 7.5 7.0
15.0 13.7 9.0 8.5 8.0 7.7 7.5 7.0
Notes:
TC: Total Capacity(kW) 3. In accordance with operation limits of outdoor unit, applicable range of
1. Capacity tables show the representative value of conditions which may occur. capacity tables is different.
2. is shown as reference. When selecting the outdoor units, avoid the 4. Refer to Capacity Correction Factor in the outdoor unit PDB for the actual
outdoor air temperature range shown by . performance data of each indoor unit and outdoor unit combination.

ART COOL Mirror _ 11


7. Air Velocity and Temperature Distribution
ARNU07GSE*2
Cooling Heating
Discharge angle:45° Discharge angle:60°

Air velocity [m/s] Air velocity [m/s]


2.7m 2.7m

2m 2m

2.0 2.0
1.5
1m 1m
1.5
1.0 0.5 1.0
0.5
0m 0m
5m 4m 3m 2m 1m 0m 5m 4m 3m 2m 1m 0m

Temperature [°C] Temperature [°C]


2.7m 2.7m
Indoor Units

2m 2m
33
18
30
20 1m
1m
24
22
24 21 27

0m 0m
5m 4m 3m 2m 1m 0m 5m 4m 3m 2m 1m 0m

ARNU12GSE*2

Cooling Heating
Discharge angle:45° Discharge angle:60°

Air velocity [m/s] Air velocity [m/s]


2.7m 2.7m

2m 2m

2.0
2.0

1m 1.5 1m
1.5
0.5
1.0
1.0
0.5
0m 0m
5m 4m 3m 2m 1m 0m 5m 4m 3m 2m 1m 0m

Temperature [°C] Temperature [°C]

2.7m 2.7m

2m 2m

33
18
30
1m 21 1m
20
24
27
22
24
0m 0m
5m 4m 3m 2m 1m 0m 5m 4m 3m 2m 1m 0m

12 _ ART COOL Mirror


8. Electric Characteristics
Units Power Supply IFM Input(W)
Model Type Hz Volts Voltage Range MCA MFA kW FLA Cooling Heating
ARNU07GSE*2 SE 0.29 15 0.02 0.23 40 40
ARNU09GSE*2 SE 0.29 15 0.02 0.23 40 40
ARNU12GSE*2 SE Max:264 0.29 15 0.02 0.23 40 40
50 220 - 240
ARNU15GSE*2 SE Min:198 0.29 15 0.02 0.23 40 40
ARNU18GS8*2 S8 0.29 15 0.02 0.23 35 35
ARNU24GS8*2 S8 0.29 15 0.02 0.23 35 35
ARNU07GSE*2 SE 0.29 15 0.02 0.23 40 40
ARNU09GSE*2 SE 0.29 15 0.02 0.23 40 40
ARNU12GSE*2 SE Max:242 0.29 15 0.02 0.23 40 40
60 220
ARNU15GSE*2 SE Min:198 0.29 15 0.02 0.23 40 40
ARNU18GS8*2 S8 0.29 15 0.02 0.23 35 35
ARNU24GS8*2 S8 0.29 15 0.02 0.23 35 35

Indoor Units
Symbols:
MCA : Minimum Circuit Amperes (A)
MFA : Maximum Fuse Amperes(see note 5)
kW : Fan Motor Rated Output(kW)
FLA : Full Load Amperes(A)
IFM : Indoor Fan Motor

Note :
1. Voltage Range
Units are suitable for use on electrical system where voltage supplied to unit terminals is not below or above the
listed range limits.
2. Maximum allowable voltage unbalance between phase is 2%.
3. MCA/MFA
MCA = 1.25 x FLA
MFA ≤ 4 x FLA
( Next lower standard fuse rating. Minimum 15A)
4. Select wire size based on the MCA.

ART COOL Mirror _ 13


9. Sound Levels
Overall
Notes:
1. Sound measured at each 1m away from the front and bottom of the unit
2. Operating condition
- Power source : 220-240V 50Hz / 220V 60Hz
- Cooling : Indoor temperature (27°C DB, 19°C WB),
1m Outdoor temperature (35°C DB, 24°C WB)
- Heating : Indoor temperature (20°C DB, 15°C WB),
Outdoor temperature (7°C DB, 6°C WB)
1m 3. Reference accoustic pressure 0dB = 20μPa
4. Sound level will vary depending on a range of factors such as
Microphone the construction(acoustic absorption coefficient) of particular
❈ Measuring place : Anechoic chamber room in which the equipment in installed.

Sound Levels dB(A)


Model
H M L
ARNU07GSE*2 37 33 23
ARNU09GSE*2 39 35 25
ARNU12GSE*2 41 36 27
ARNU15GSE*2 42 36 27
ARNU18GS8*2 37 34 31
Indoor Units

ARNU24GS8*2 43 37 32

Sound Pressure Level


80
ARNU07GSE*2 80
ARNU09GSE*2 ARNU12GSE*2
80
Octave Band Sound Pressure Level (0dB = 20μPa)

70 70 70
Octave Band Sound Pressure Level (0dB = 20μPa)

Octave Band Sound Pressure Level (0dB = 20μPa)


NC-65 NC-65 NC-65
60 60 60
NC-60 NC-60 NC-60

NC-55 NC-55 NC-55


50 50 50
NC-50 NC-50 NC-50

NC-45 NC-45 NC-45


40 40 40
NC-40 NC-40 NC-40

NC-35 30 NC-35 NC-35


30 30
NC-30 NC-30 NC-30

20 NC-25 20 NC-25 20 NC-25


Approximate Approximate Approximate
NC-20 NC-20 NC-20
Hearing Hearing Hearing
Threshold Threshold NC-15 Threshold
10 NC-15 10 10 NC-15
63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

ARNU15GSE*2 ARNU18GS8*2 ARNU24GS8*2


80 80 80

70
Octave Band Sound Pressure Level (0dB = 20μPa)

70 70
Octave Band Sound Pressure Level (0dB = 20μPa)

Octave Band Sound Pressure Level (0dB = 20μPa)

NC-65 NC-65 NC-65


60 60 60
NC-60 NC-60 NC-60

NC-55 NC-55 NC-55


50 50 50

NC-50 NC-50 NC-50

NC-45 NC-45 NC-45


40 40 40

NC-40 NC-40 NC-40

NC-35 NC-35 NC-35


30 30 30
NC-30 NC-30 NC-30

20 NC-25 20 NC-25 20 NC-25


Approximate Approximate Approximate
NC-20 NC-20 NC-20
Hearing Hearing Hearing
Threshold NC-15 Threshold NC-15 Threshold NC-15
10 10 10
63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

14 _ ART COOL Mirror


10. Installation

• Please read this instruction sheet completely before installing the product.
• When the power cord is damaged, replacement work shall be performed by authorized personnel only.
• Installation work must be performed in accordance with the national wiring standards by authorized personnel only.

Installation Parts Provided

1. Type "A" screw

2. Installation Plate

Indoor Units
Required Parts Required Tools
❏ Installation plate ❏ Level gauge
❏ Four type "A" screws ❏ Screw driver
❏ Connecting cable ❏ Electric drill
❏ Hole core drill

❏ Pipes: Gas side


Liquid side
❏ Insulation materials
❏ Additional drain pipe ❏ Flaring tool set
❏ Specified torque wrenches
❏ Spanner......................................................Half union

❏ A glass of water
❏ Screw driver
❏ Thermometer

ART COOL Mirror _ 15


10. Installation
10.1 Selection of the best location
More than 100mm
• There should not be any heat source or steam near the More than 200mm
unit.
• There should not be any obstacles to prevent the air cir-
culation.
More than 100mm
• A place where air circulation in the room will be good.
• A place where drainage can be easily obtained. More than 2300mm
• A place where noise prevention is taken into considera-
tion.
• Do not install the unit near the door way.
S8 chassis
• Ensure the spaces indicated by arrows from the wall, ceil- Installation Plate
ing, fence, or other obstacles.

The mounting wall should be strong and solid enough to Chassis


protect it from the vibration. Hook
Indoor Units

Mount the installation plate on the wall with four Type Type “A”
"A" screws.
(If mounting the unit on the concrete wall, consider using
SE chassis
anchor bolts.)
• Always mount the Installation plate horizontally by Installation Plate
aligning the marking-off line by means of the thread
and a level.

Chassis
Hook

Type “A”

The lower left and the right side of Installation Plate

S8 chassis SE chassis

Ø70mm Ø70mm
110mm
110mm

Installation plate
Installation plate
133mm 100mm Ø70mm Ø70mm
85mm 65mm
Left rear piping Right rear piping Left rear piping Right rear piping

CAUTION : In case that the unit is installed near the sea, the installation parts
may be corroded by salt. The installation parts (and the unit) should be taken
appropriate anti-corrosion measures.

16 _ ART COOL Mirror


10. Installation
Preparing work for installation
■ Preparing the indoor unit's piping and drain hose for 3. Tape the tubing, drain hose and the connect-
installation through the wall. ing cable. Be sure that the drain hose is locat-
■ Remove the plastic tubing retainer(see illustration ed at the lowest side of the bundle. Locating
below) and pull the tubing and drain hose away from at the upper side can cause drain pan to over-
chassis. flow inside the unit.
■ Replace the plastic tubing holder in the original position.

Tape
Connecting
pipe

Drain hose
Connecting cable

Indoor Units
NOTICE : If the drain hose is routed inside the room,
insulate the hose with an insulation material* so that drip-
ping from "sweating"(condensation) will not damage furni-
ture or floors.

For right rear piping *Foamed polyethylene or equivalent is recommended.

1. Route the indoor tubing and the drain hose in 4. Indoor unit installation
the direction of rear left. ■ Hook the indoor unit onto the upper portion of the
installation plate.(Engage the two hooks of the rear
top of the indoor unit with the upper edge of the
installation plate.) Ensure that the hooks are properly
seated on the installation plate by moving it left and
Drain hose
right.

Connecting

Drain hose

2. Insert the connecting cable into the indoor Press the lower left and right sides of the unit against
unit from the outdoor unit through the piping the installation plate until the hooks engage into their
hole. slots(clicking sound).
■ Do not connect the cable to the indoor unit.
■ Make a small loop with the cable for easy connection
later.

ART COOL Mirror _ 17


10. Installation
5. Connecting the pipings to the indoor unit and ■ Wrap the area which accommodates the rear pip-
drain hose to drain pipe. ing housing section with vinyl tape.
■ Align the center of the pipings and sufficiently tighten
Connection Indoor
the flare nut by hand. pipe unit pipe
Vinyl tape Wrap with vinyl tape
(wide)
Connecting cable

Indoor unit tubing Flare nut Pipings


Pipe

Vinyl tape(narrow)
■ Tighten the flare nut with a wrench.

■ Bundle the piping and drain hose together by


Spanner (fixed) wrapping them with vinyl tape over the range with-
Flare nut in which they fit into the rear piping housing sec-
Connection tion.
Torque Wrap with vinyl tape
wrench pipe
Indoor Units

Indoor Pipe
unit tubing

■ Mount the clamp on the boss with a type "B" Vinyl tape(wide)
Drain hose
screw.(optional)

Type "B" screw Drain hose


Clamp For left rear piping
Boss

1. Route the indoor tubing and the drain hose to


the required piping hole position.

■ When extending the drain hose at the indoor


unit, install the drain pipe.

Drain pipe

Indoor unit
drain hose
Vinyl tape(narrow)
Adhesive 2. Insert the piping, drain hose and the connect-
ing cable into the piping hole.
6. Wrap the insulation material around the con-
necting portion.
■ Overlap the connection pipe insulation material Connecting cable

and the indoor unit pipe insulation material. Bind Drain pipe
them together with vinyl tape so that there is no
gap.
Plastic bands
Insulation material

18 _ ART COOL Mirror


10. Installation
3. Insert the connecting cable into the indoor ■ When extending the drain hose at the indoor unit,
unit. install the drain pipe.
■ Don't connect the cable to the indoor unit.
■ Make a small loop with the cable for easy connec-
tion later. Drain hose

4. Tape the drain hose and the connecting cable.


Indoor unit drain hose
• Connecting cable
Vinyl tape(narrow)
Adhesive

7. Wrap the insulation material around the con-


necting portion.
■ Overlap the connection pipe heat insulation and
the indoor unit pipe heat insulation material. Bind
them together with vinyl tape so that there is no
gap.
5. Indoor unit installation

Indoor Units
Plastic bands
Insulation material
■ Hang the indoor unit from the hooks at the top of
the installation plate.
■ Insert the spacer etc. between the indoor unit and
the installation plate and separate the bottom of
the indoor unit from the wall.
■ Wrap the area which accommodates the rear pip-
ing housing section with vinyl tape.
Indoor unit
Spacer
Connection Indoor
pipe unit piping
Installation plate Vinyl tape
(wide) Wrap with vinyl tape
80mm
Pipe
6. Connecting the pipings to the indoor unit and
Vinyl tape
the drain hose to drain pipe. (narrow)
Connecting
■ Align the center of the pipings and sufficiently cable
tighten the flare nut by hand.

Indoor unit tubing Flare nut Pipings

■ Tighten the flare nut with a wrench.

Spanner (fixed)

Flare nut
Torque Connection
wrench pipe

Indoor
unit tubing

ART COOL Mirror _ 19


10. Installation
■ Bundle the piping and drain hose together by 9. Set the pipings and the drain hose to the back
wrapping them with cloth tape over the range of the chassis with the tubing holder.
within which they fit into the rear piping housing ■ Hook the edge of tubing holder to tap on chassis
section. and push the bottom of tubing holder to be
engaged at the bottom of chassis.
Pipe
Drain hose
Vinyl tape
(narrow)

Wrap with
vinyl tape(wide)
Tubing holder

10. Indoor unit installation


Indoor Units

8. Reroute the pipings and the drain hose across


■ Remove the spacer.
the back of the chassis.
■ Ensure that the hooks are properly seated on the
installation plate by moving it left and right.

Connecting

Piping for Drain hose


passage through
piping hole

Press the lower left and right sides of the unit


against the installation plate until the hooks engage
into their slots(clicking sound).

20 _ ART COOL Mirror


10. Installation
10.2 Connection of Pipings

1. To remove the front panel from the indoor unit, 2. To check the drainage.
remove the front panel from the indoor unit ■ Pour a glass of water on the evaporator.
cabinet. ■ Ensure the water flows through the drain hose of the indoor
■ Set the air direction louvers up-and-down to the unit without any leakage and goes out the drain exit.
position(horizontally) by hand.
■ Remove the securing screws that retain the front
Connecting area
panel. Pull the lower left and right sides of the grille drain hose
toward you and lift it off.
Leakage
checking

Drain pan

Drain

Indoor Units
hose
Leakage
checking
Front panel
■ The drain hose should point downward for easy drain flow.

Downward slope

■ Do not make drain piping.

Accumulated
Do not raise
drain water
Air Tip of drain hose
Less than
dipped in water
50mm gap

Water Water Water


Waving
leakage leakage leakage Ditch

10.3 Connect the cable to the


indoor unit
1. Connect the wires to the terminals on the
control board individually according to the
outdoor unit connection.
• Ensure that the color of the wires of outdoor
unit and the terminal No. are the same as
those of indoor unit respectively. Remote control
co cord

Connecting cable

ART COOL Mirror _ 21


10. Installation
[Indoor Unit side] [Outdoor Unit side]

[Type 1]

Terminal Block Indoor SODU B SODU A IDU B IDU A INT B INT A


1(L1) 2(L2) 3 4

INDOOR POWER INPUT


[Type 2]

Terminal Block Indoor SODU IDU INTERNET DRY1 DRY2 GND 12V
1(L1) 2(L2) 3 4 B A - - B A - - - -

INDOOR POWER INPUT


[Type 3]
Terminal block of outdoor unit
Indoor Units

Terminal Block Indoor Central controller Indoor unit Outdoor unit


1(L1) 2(L2) 3 4 12V GND DRY2 DRY1 CEN CEN IDU IDU SODU SODU

INDOOR POWER INPUT

2. Attach the Grille onto the cabinet.


• Grasp lower the left and right side of the Grille and engage four
tabs on the top inside edge of the chassis.
• Press the Grille toward the chassis until it is back into its original
place.

CAUTION
After the confirmation of the above conditions, prepare the wiring as follows:
1) As for the method of wiring, follow the circuit diagram posted on the inside of control cover.
2) The screw which fasten the wiring in the casing of electrical fittings are liable to come loose from
vibrations to which the unit is subjected during the course of transportation. Check them and make
sure that they are all tightly fastened. (If they are loose, it could cause burn-out of the wires.)
3) Specification of power source.
4) Confirm that electrical capacity is sufficient.
5) See to that the starting voltage is maintained at more than 90 percent of the rated voltage marked
on the name plate.
6) Confirm that the cable thickness is as specified in the power source specification.
(Particularly note the relation between cable length and thickness.)
7) Always install an earth leakage circuit breaker in a wet or moist area.
8) The following would be caused by voltage drop.
• Vibration of a magnetic switch, which will damage the contact point, fuse breaking, disturbance of the
normal function of the overload.
9) The means for disconnection from a power supply shall be incorporated in the fixed wiring and
have an air gap contact separation of at least 3mm in each active(phase) conductor.

22 _ ART COOL Mirror


10. Installation
WIRED REMOTE CONTROLLER INSTALLATION
• Since the room temperature sensor is in the remote controller, the remote controller box should be installed in a place away
from direct sunlight, high humidity and direct supply of cold air to maintain proper space temperature.
Install the remote controller about 5ft(1.5m) above the floor in an area with good air circulation at an average temperature.
Do not install the remote controller where it can be affected by:
- Drafts, or dead spots behind doors and in corners.
- Hot or cold air from ducts.
- Radiant heat from sun or appliances.
- Concealed pipes and chimneys.
- Uncontrolled areas such as an outside wall behind the remote controller.
- This remote controller is equipped with a seven segment LED. display. For proper display of the remote controller
LED's, the remote controller should be installed properly as shown in Fig.1.
(The standard height is 1.2~1.5 m from floor level.)

Indoor Units
Remote Controller
TEMP
yes

no
TEMP

Remote Controller

no
TEMP
5feet
Remote
Controller

(1.5meters)
no

Fig.1 Typical locations for remote controller

ART COOL Mirror _ 23


11. Accessories
Standard Accessories
Type "A" screws and
Name Installation panel plastic anchors (Other)

Quantity 1 set 4 set

SE

• Owner's manual
• Installation manual
Shape
S8
Indoor Units

CAUTION
• Use only those accessories (Standard or optional) which have designated specifications.

24 _ ART COOL Mirror


Indoor unit
ART COOL Gallery
1. List of functions

2. Specifications

3. Dimensions

4. Piping Diagrams

5. Wiring Diagrams

6. Capacity Tables

7. Air Velocity and Temperature Distribution

8. Electric Characteristics

9. Sound Levels

10. Installation

11. Accessories
1. List of functions

Category Function ARNU07GSF*2, ARNU09GSF*2, ARNU12GSF*2

Air supply outlet 3


Airflow direction control(left & right) X
Airflow direction control(up & down) Auto
Auto swing(left & right) X
Auto swing(up & down) O
Air flow
Airflow steps(fan/cool/heat) 3/4/3
Chaos swing X
Chaos wind(auto wind) O
Jet cool(Power wind) O
Swirl wind -
Deodorizing filter X
Air purifying Plasma air purifier O
Prefilter(washable / anti-fungus) O
Drain pump -
E.S.P. control -
Installation
Electric heater(operation) -

Indoor Units
High ceiling operation -
Hot start O
Reliability Self diagnosis O
Soft dry operation O
Auto changeover O(Heat recovery)
Auto cleaning O
Auto operation(artificial intelligence) O(Heat pump or Cooling only)
Auto restart operation O
Child lock O
Convenience Forced operation O
Group control O
Sleep mode O
Timer(on/off) O
Timer(weekly) O
Two thermistor control O
Wide wired remote controller PQRCVSL0/PQRCVSL0QW
Deluxe wired remote controller X
Individual
Simple wired remote controller PQRCVCL0Q(W)
control
Wired remote controller(for hotel use) PQRCHCA0Q(W)
Wireless LCD remote control PQWRH(C)Q0FDB
Zone control -
CTIE -
Special Electro thermostat -
function kit Remote temperature sensor -
Group control wire PZCWRCG3
Dry contact PQDSA(1)/PQDSB(1)/PQDSBC/PQDSBNGCM1/PQDSBCGCD0

O : Applied X : Not applied – : No relation


Option : Model name & price are different according to options, and assembled in factory with main unit.
Accessory : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate
package.

ART COOL Gallery _ 1


2. Specifications

Type ART COOL Gallery


Model Unit ARNU07GSF*2 ARNU09GSF*2 ARNU12GSF*2
kW 2.2 2.8 3.6
Cooling Capacity kcal/h 1,900 2,400 3,100
Btu/h 7,500 9,600 12,300
kW 2.5 3.2 4.0
Heating Capacity kcal/h 2,200 2,800 3,400
Btu/h 8,500 10,900 13,600
mm 600 x 600 x 146 600 x 600 x 146 600 x 600 x 146
Dimensions(WxHxD) Body
inch 23-5/8 x 23-5/8 x 5-25/32 23-5/8 x 23-5/8 x 5-25/32 23-5/8 x 23-5/8 x 5-25/32
Coil Rows x Columns x FPI 2x20x21 2x20x21 2x20x21
Face Area m2 0.18 0.18 0.18
Type Turbo Fan Turbo Fan Turbo Fan
Motor Output x Number W 30 30 30
Running Current A 0.16 0.16 0.16
Fan Air Flow Rate(H / M / L) CMM 8.1 / 6.3 / 4.2 8.1 / 6.3 / 4.2 9.3 / 7.7 / 6.0
cfm 286 / 222 / 148 286 / 222 / 148 328 / 272 / 212
Indoor Units

Drive Direct Direct Direct


Motor type BLDC BLDC BLDC
Temperature Control Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating
Sound Absorbing Thermal Insulation Material Foamed polystrene Foamed polystrene Foamed polystrene
Air Filter Resin Net(washable) Resin Net(washable) Resin Net(washable)
Safety Device Fuse Fuse Fuse
Liquid Side mm(inch) Ø6.35(1/4) Ø6.35(1/4) Ø6.35(1/4)
Pipe Connections Gas Side mm(inch) Ø12.7(1/2) Ø12.7(1/2) Ø12.7(1/2)
Drain Pipe(Internal Dia.) mm(inch) 12.2(15/32) 12.2(15/32) 12.2(15/32)
Net Weight kg(lbs) 15(33.1) 15(33.1) 15(33.1)
Noise Level(Sound Press, 1m, H / M / L) dB(A) 38 / 32 / 27 38 / 32 / 27 44 / 38 / 32
Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50
1, 220, 60 1, 220, 60 1, 220, 60
Refrigerant Control EEV EEV EEV
Power cable mm2 CV1.5 x 3C CV1.5 x 3C CV1.5 x 3C
Transmission cable mm2 CVV-SB 1.0~1.5 x 2C CVV-SB 1.0~1.5 x 2C CVV-SB 1.0~1.5 x 2C
Front Panel('*' Position) E:Red, V:Silver, G:Gold, 1: Kiss (Photo changeable)

Notes:-
Conversion Formula
1. Capacities are based on the following conditions:
Cooling • Indoor temp. 27°C[80.6°F]DB/ 19°C[66.2°F]WB kcal/h= kW x 860
• Outdoor temp. 35°C[95°F]DB/ 24°C[75.2°F]WB Btu/h = kW x 3412
• Interconnecting Piping Length 7.5m cfm = m3/min x 35.3
• Level Difference of Zero l/s = CMM x 1000/60
Heating • Indoor temp. 20°C[68°F]DB/ 15°C[59°F]WB
• Outdoor temp. 7°C[44.6°F]DB/ 6°C[42.8°F]WB
• Interconnecting Piping Length 7.5m
• Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve
6. Anechoic chamber conversion value is measured at 1 m downward from unit centre.
The values depends on the ambient conditions and values are normally higher in actual operation.

• Panel color: E(Red), V(Silver), G(Gold) ’ Panel type


1: Kiss (Photo changeable) ’ Gallery type

2 _ ART COOL Gallery


2 ART COOL Gallery
W D
ARNU07GSF*2
ARNU09GSF*2
ARNU12GSF*2

H (unit : mm)
3. Dimensions

Model W H D
1
ARNU07GSF*2
1 ARNU09GSF*2 600 600 146
ARNU12GSF*2

(unit : mm)
Pipe Hole
Number Name Descripition
1 Air discharge grill
2 Air suction grill
1
Hanger Hole
500
Note
1. Unit should be installed in compliance with the installation manual
in the product box.
2. Unit shall be grounded in accordance with the local regulations or
applicable national codes.

525
Fix Hole

76, Seongsan-dong, Changwon City, Gyeongnam,


641-713, Korea CHASSIS CODE: SF

ART COOL Gallery _ 3


Indoor Units
4. Piping Diagrams

:Cooling
Heat Exchanger EEV :Heating
Filter
Th3 Th2
Turbo Fan Filter

Th1 lndoor unit


Indoor Units

Refrigerant pipe connection port diameter


[Unit: mm(inch)]
Model Gas Liquid
ARNU07GSF*2 Ø12.7(1/2) Ø6.35(1/4)

ARNU09GSF*2 Ø12.7(1/2) Ø6.35(1/4)

ARNU12GSF*2 Ø12.7(1/2) Ø6.35(1/4)

*Panel color :E(Red), V(Silver), G(Gold), 1(Kiss (Photo changeable))

LOC. Description PCB Connector


Th1 Room thermistor
CN-TH1
Th2 Pipe in thermistor
Th3 Pipe out thermistor CN-TH1

4 _ ART COOL Gallery


5. Wiring Diagrams
SF Chassis

Indoor Units
CONNECTOR NUMBER LOCATION POINT FUNCTION
CN-MOTOR1 Fan motor output Motor output of BLDC
CN-COM Communication Communication between indoor and outdoor
CN-EEV EEV output EEV control output
CN-D1 Display Display of indoor status
CN-LR1 Step motor Step motor output for left/right
CN-LR2 Step motor Step motor output for left/right
CN-UD Step motor Step motor output
CN-TH1 Room/pipe sensor Room and pipe thermistor
CN-TH2 Discharge pipe sensor Discharge pipe thermistor
CN-REMO Remote controller Remote control line
CN-CC Dry contact Dry contact line
CN-HVB Air clean Air clean control

ART COOL Gallery _ 5


6. Capacity Tables
6.1 Cooling Capacity
Cooling Capacity

Indoor air temp. (DB/WB, °C)


Capacity Outdoor 20 23 26 27 28 30 32
Index air temp. 14 16 18 19 20 22 24
(DB, °C) TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.9 1.7
12 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.9 1.6
14 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.8 1.6
16 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.8 1.6
18 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.7 1.6
20 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.7 1.6
21 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.7 1.5
23 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.6 1.5
2.2 25 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.6 1.5
27 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.5 1.6 2.6 1.5
Indoor Units

29 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.5 1.6 2.5 1.5
31 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.5 1.6 2.5 1.4
33 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.4 1.5 2.5 1.4
35 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.4 1.5 2.4 1.4
37 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.3 1.5 2.4 1.4
39 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.2 1.5 2.3 1.5 2.3 1.4
10 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.7 2.1
12 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.6 2.1
14 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.6 2.1
16 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.5 2.0
18 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.5 2.0
20 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.4 2.0
21 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.4 2.0
23 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.4 1.9
2.8 25 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.3 2.1 3.3 1.9
27 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.2 2.1 3.3 1.9
29 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.2 2.0 3.2 1.9
31 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.1 2.0 3.2 1.8
33 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.1 2.0 3.1 1.8
35 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.0 1.9 3.1 1.8
37 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 2.9 2.0 3.0 1.9 3.0 1.8
39 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 2.9 2.0 2.9 1.9 3.0 1.7
10 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.7 2.8
12 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.7 2.7
14 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.6 2.7
16 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.6 2.7
18 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.5 2.6
20 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.4 2.6
21 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.4 2.6
23 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.8 4.3 2.5
3.6 25 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.2 2.8 4.3 2.5
27 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.1 2.7 4.2 2.5
29 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.1 2.7 4.2 2.4
31 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.0 2.6 4.1 2.4
33 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.0 2.6 4.0 2.4
35 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 3.9 2.5 4.0 2.3
37 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.7 2.6 3.8 2.5 3.9 2.3
39 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.7 2.6 3.7 2.4 3.8 2.2
Notes:
TC: Total Capacity(kW), SHC: Sensible Heat Capacity(kW) 2. Refer to Capacity Correction Factor in the outdoor unit PDB for
1. Capacity tables show the representative value of conditions the actual performance data of each indoor unit and outdoor unit
which may occur. combination.

6 _ ART COOL Gallery


6. Capacity Tables
6.2 Heating Capacity Heating Capacity

Outdoor air Indoor air temp. (DB, °C)


Capacity temp. 16 18 20 21 22 24
Index TC TC TC TC TC TC
DB(°C) WB(°C)
kW kW kW kW kW kW
-24.8 -25.0 1.4 1.4 1.4 1.4 1.4 1.4
-21.8 -22.0 1.7 1.7 1.7 1.7 1.7 1.7
-19.8 -20.0 1.8 1.8 1.8 1.8 1.8 1.8
-18.8 -19.0 1.9 1.9 1.9 1.9 1.9 1.9
-16.7 -17.0 2.0 2.0 2.0 2.0 2.0 2.0
-14.7 -15.0 2.1 2.1 2.1 2.1 2.1 2.0
-12.6 -13.0 2.2 2.2 2.2 2.2 2.1 2.1
-10.5 -11.0 2.3 2.3 2.2 2.2 2.2 2.2
-9.5 -10.0 2.3 2.3 2.3 2.3 2.3 2.2
-8.5 -9.1 2.3 2.3 2.3 2.3 2.3 2.2
-7.0 -7.6 2.4 2.4 2.4 2.4 2.3 2.2
2.2 -5.0 -5.6 2.5 2.5 2.5 2.4 2.3 2.2
-3.0 -3.7 2.6 2.6 2.5 2.4 2.3 2.2
0.0 -0.7 2.7 2.6 2.5 2.4 2.3 2.2
3.0 2.2 2.7 2.7 2.5 2.4 2.3 2.2
5.0 4.1 2.8 2.7 2.5 2.4 2.3 2.2

Indoor Units
7.0 6.0 2.8 2.7 2.5 2.4 2.3 2.2
9.0 7.9 2.8 2.7 2.5 2.4 2.3 2.2
11.0 9.8 2.8 2.7 2.5 2.4 2.3 2.2
13.0 11.8 2.8 2.7 2.5 2.4 2.3 2.2
15.0 13.7 2.8 2.7 2.5 2.4 2.3 2.2
-24.8 -25.0 1.9 1.9 1.8 1.8 1.8 1.8
-21.8 -22.0 2.2 2.2 2.2 2.2 2.2 2.2
-19.8 -20.0 2.4 2.4 2.3 2.3 2.3 2.3
-18.8 -19.0 2.4 2.4 2.4 2.4 2.4 2.4
-16.7 -17.0 2.5 2.5 2.5 2.5 2.5 2.5
-14.7 -15.0 2.7 2.7 2.6 2.6 2.6 2.6
-12.6 -13.0 2.8 2.8 2.8 2.8 2.7 2.7
-10.5 -11.0 2.9 2.9 2.9 2.9 2.9 2.8
-9.5 -10.0 3.0 3.0 2.9 2.9 2.9 2.8
-8.5 -9.1 3.0 3.0 3.0 3.0 3.0 2.8
-7.0 -7.6 3.1 3.1 3.1 3.1 3.0 2.8
2.8 -5.0 -5.6 3.2 3.2 3.2 3.1 3.0 2.8
-3.0 -3.7 3.4 3.3 3.2 3.1 3.0 2.8
0.0 -0.7 3.4 3.3 3.2 3.1 3.0 2.8
3.0 2.2 3.5 3.4 3.2 3.1 3.0 2.8
5.0 4.1 3.6 3.4 3.2 3.1 3.0 2.8
7.0 6.0 3.6 3.4 3.2 3.1 3.0 2.8
9.0 7.9 3.6 3.4 3.2 3.1 3.0 2.8
11.0 9.8 3.6 3.4 3.2 3.1 3.0 2.8
13.0 11.8 3.6 3.4 3.2 3.1 3.0 2.8
15.0 13.7 3.6 3.4 3.2 3.1 3.0 2.8
-24.8 -25.0 2.3 2.3 2.3 2.3 2.3 2.3
-21.8 -22.0 2.8 2.8 2.8 2.8 2.8 2.8
-19.8 -20.0 2.9 2.9 2.9 2.9 2.9 2.9
-18.8 -19.0 3.0 3.0 3.0 3.0 3.0 3.0
-16.7 -17.0 3.1 3.1 3.1 3.1 3.1 3.1
-14.7 -15.0 3.3 3.3 3.3 3.3 3.3 3.3
-12.6 -13.0 3.5 3.4 3.4 3.4 3.4 3.4
-10.5 -11.0 3.6 3.6 3.6 3.6 3.6 3.5
-9.5 -10.0 3.7 3.7 3.7 3.7 3.7 3.5
-8.5 -9.1 3.8 3.8 3.7 3.7 3.7 3.5
-7.0 -7.6 3.9 3.9 3.9 3.8 3.7 3.5
3.6 -5.0 -5.6 4.0 4.0 4.0 3.9 3.7 3.5
-3.0 -3.7 4.2 4.1 4.0 3.9 3.7 3.5
0.0 -0.7 4.3 4.1 4.0 3.9 3.7 3.5
3.0 2.2 4.4 4.3 4.0 3.9 3.7 3.5
5.0 4.1 4.5 4.3 4.0 3.9 3.7 3.5
7.0 6.0 4.5 4.3 4.0 3.9 3.7 3.5
9.0 7.9 4.5 4.3 4.0 3.9 3.7 3.5
11.0 9.8 4.5 4.3 4.0 3.9 3.7 3.5
13.0 11.8 4.5 4.3 4.0 3.9 3.7 3.5
15.0 13.7 4.5 4.3 4.0 3.9 3.7 3.5
Notes:
TC: Total Capacity(kW) 3. In accordance with operation limits of outdoor unit, applicable range of
1. Capacity tables show the representative value of conditions which may occur. capacity tables is different.
2. is shown as reference. When selecting the outdoor units, avoid the 4. Refer to Capacity Correction Factor in the outdoor unit PDB for the actual
outdoor air temperature range shown by . performance data of each indoor unit and outdoor unit combination.

ART COOL Gallery _ 7


7. Air Velocity and Temperature Distribution
ARNU07GSF*2
Cooling Heating
Discharge angle:40° Discharge angle:50°

Air velocity [m/s] Air velocity [m/s]


2.7m 2.7m

2m 2m
2.5
2.0 2.0
1.5
1m 1m

1.5
1.0
1.0
0.5 0.5
0m 0m
5m 4m 3m 2m 1m 0m 5m 4m 3m 2m 1m 0m

Temperature [°C] Temperature [°C]


2.7m 2.7m
Indoor Units

2m 2m
11 45
13 43

1m 1m
15 41

39
19 17 35 37
33
0m 0m
5m 4m 3m 2m 1m 0m 5m 4m 3m 2m 1m 0m

ARNU09GSF*2
Cooling Heating
Discharge angle:40° Discharge angle:50°

Air velocity [m/s] Air velocity [m/s]


2.7m 2.7m

2m 2m

2.0 2.0

1m 1m
1.5
1.5

1.0 0.5 1.0


0.5 0m
0m
5m 4m 3m 2m 1m 0m 5m 4m 3m 2m 1m 0m

Temperature [°C] Temperature [°C]


2.7m 2.7m

2m 2m

11 43
13
1m 1m
41
15 39
19 17 33 35 37
0m 0m
5m 4m 3m 2m 1m 0m 5m 4m 3m 2m 1m 0m

8 _ ART COOL Gallery


7. Air Velocity and Temperature Distribution
ARNU12GSF*2
Cooling Heating
Discharge angle:40° Discharge angle:50°

Air velocity [m/s] Air velocity [m/s]


2.7m 2.7m

2m 2m
2.5
2.0 2.0
1m 1m
1.5
1.5
0.5 1.0 0.5 1.0
0m 0m
5m 4m 3m 2m 1m 0m 5m 4m 3m 2m 1m 0m

Temperature [°C] Temperature [°C]


2.7m 2.7m

Indoor Units
2m 2m

11 45
13 43
1m 1m
15
41
37 39
19 17 33 35
0m 0m
5m 4m 3m 2m 1m 0m 5m 4m 3m 2m 1m 0m

ART COOL Gallery _ 9


8. Electric Characteristics
Units Power Supply IFM Input(W)
Model Type Hz Volts Voltage Range MCA MFA kW FLA Cooling Heating
ARNU07GSF*2 SF 0.23 15 0.024 0.18 35 35
Max:264
ARNU09GSF*2 SF 50 220 - 240 0.23 15 0.024 0.18 35 35
Min:198
ARNU12GSF*2 SF 0.23 15 0.024 0.18 35 35
ARNU07GSF*2 SF 0.23 15 0.024 0.18 35 35
Max:242
ARNU09GSF*2 SF 60 220 0.23 15 0.024 0.18 35 35
Min:198
ARNU12GSF*2 SF 0.23 15 0.024 0.18 35 35

Symbols:
MCA: Minimum Circuit Amperes (A)
MFA : Maximum Fuse Amperes(see note 5)
kW : Fan Motor Rated Output(kW)
FLA : Full Load Amperes(A)
Indoor Units

IFM : Indoor Fan Motor

Note :
1. Voltage Range
Units are suitable for use on electrical system where voltage supplied to unit terminals is not below or above the
listed range limits.
2. Maximum allowable voltage unbalance between phase is 2%.
3. MCA/MFA
MCA = 1.25 x FLA
MFA ≤ 4 x FLA
( Next lower standard fuse rating. Minimum 15A)
4. Select wire size based on the MCA.
5. Instead of fuse, use Circuit Breaker.

10 _ ART COOL Gallery


9. Sound Levels
Overall
Notes:
1. Sound measured at 1m away from the front and 0.8m away
from the bottom of the unit
2. Operating condition
- Power source : 220-240V 50Hz / 220V 60Hz
- Cooling : Indoor temperature (27°C DB, 19°C WB),
Outdoor temperature (35°C DB, 24°C WB)
1m - Heating : Indoor temperature (20°C DB, 15°C WB),
Outdoor temperature (7°C DB, 6°C WB)
0.8m 3. Reference accoustic pressure 0dB = 20μPa
4. Sound level will vary depending on a range of factors such as
the construction(acoustic absorption coefficient) of particular
Microphone room in which the equipment in installed.
❈ Measuring place : Anechoic chamber

Sound Levels dB(A)


Model
H M L
ARNU07GSF*2 38 32 27

Indoor Units
ARNU09GSF*2 38 32 27

ARNU12GSF*2 44 38 32

Sound Pressure Level


ARNU07GSF*2 ARNU12GSF*2
ARNU09GSF*2
80 80

70 70
Octave Band Sound Pressure Level (0dB = 20μPa)

Octave Band Sound Pressure Level (0dB = 20μPa)

NC-65 NC-65
60 60
NC-60 NC-60

NC-55 NC-55
50 50
NC-50 NC-50
NC-45 NC-45
40
40
NC-40
NC-40
NC-35
30 NC-35
30
NC-30
NC-30

20 NC-25
20 NC-25
Approximate
NC-20 Approximate
Hearing NC-20
Threshold Hearing
NC-15
10 Threshold NC-15
63 125 250 500 1000 2000 4000 8000 10
Octave Band Center Frequency (Hz) 63 125 250 500 1000 2000 4000 8000
Octave Band Center Frequency (Hz)

ART COOL Gallery _ 11


10. Installation
• Please read the instruction sheets completely before installing the product.
• When the power cord is damaged, replacement work shall be performed by authorized personnel only.
• Installation work must be performed in accordance with the national wiring standards by authorized personnel only.

Installation Parts Provided

1. Installation guide map

2. Type "A" screw and plastic anchors


Indoor Units

Required Parts Required Tools


o Four type "A" screws o Level gauge
o Connecting cable o Screw driver
o Pipes: Gas side o Electric drill
Liquid side o Hole core drill
o Flaring tool set
o Insulation materials o Specified torque wrenches
o Additional drain pipe o Spanner......................................................Half union
o A glass of water
o Screw driver
o Thermometer

10.1 Selection of the best location


• Do not have any heat or steam near the unit. More than
• Select a place where there are no obstacles in front of the unit. 200mm
More than
• Make sure that condensation drainage can be conveniently
500mm
routed away.
Do not install near a doorway.
• Ensure that the space around the left and right of the unit is
more than 500mm. The unit should be installed as high on the More than
wall as possible, allowing a minimum of 200mm from ceiling. 500mm
• Use a stud finder to locate studs to prevent unnecessary dam- More than 1500mm
age to the wall.

12 _ ART COOL Gallery


10. Installation
10.2 Preparing Work for Installation
Open panel front
1. Pull the upper part of the front panel.
2. Lift up the panel.
3. To detach the front panel, remove the two screws at the lower part.
4. Detach the front panel from the body.
5. To detach the panel, disconnect the connector at the upper part.

Indoor Units
Panel Front
Connector

Cover pipe and cover side remove


1. Please remove the screw of the center tuning cover.
2. Pull up the side cover of desired connecting direction, then
cover side is separated.
3. Pick the pipe hole of the side cover.
CAUTION: After removing the pipe hole,
cut the burr for safety. Pipe hole

Side cover
NOTICE When making pipe path through rear
wall, you donʼt need to pick the pipe hole.

Drain hose junction


1. Remove the rubber stopple in the desired drain
direction.
2. Insert drain hose into the handle of drain pan, and
join drain hose and connecting hose according to
the figure by.
Adhesive Onlythe
Only the
desired
desireddirection
direction

Connecting
part
Drain
hose rubber cap

ART COOL Gallery _ 13


10. Installation
10.3 Fixing Indoor Unit
1. Attach an Installation guide map on the 2. Look at suited horizon by horizontal
desired surface. meter on the horizontal setting line, and
INSTALLATION GUIDE MAP fix lightly the map by adhesive tape.
IN
ST
AL
LA
Horizontality TIO
N
GU
ID
EM
AP

3. Make a hole with a diameter of 6mm and 4. Drill the pierted part as a diameter of 50mm
depth of 30-35mm by piercing a screw for connecting piping. (In case of piercing
point. IN
ST
AII
rear surface)
AT
IO
N
GU
ID
EM
AP
Indoor Units

5. Drive the fore plastic anchors into drilled 6. First, Drive the two points of the upper
points. IN
ST
AL
parts by screws. (Leave 10mm for hanging
LA
TIO
N
GU
the product)
ID
EM
IN
AP

10
mm ST
AL
LA
TIO
Plastic anchors
N
GU

7. Hang the hole of product at the upper 8. Drive the lower parts after facing the hole
screws, and remove the map. (Falling of product with plastic anchors, and fix
attention) INS
TAL
LAT
ION
completely the upper screws.
GUID
EM
AP

Plastic anchors
Hanger hole
(Rear side of
the product)

9. Check the fixed product with light power. 10. In case of nothing wrong, connect the
pipe and the wire. (Refer to installation
manual)

14 _ ART COOL Gallery


10. Installation
10.4 Connecting the Piping
Preparing the indoor unit's piping and drain hose for 3. Connecting the pipings to the in door unit and
installation through the wall. drain hose to drain pipe
o Align the center of the pipings and sufficiently
1. Route the indoor tubing and the drain hose in
tighten the flare nut by hand.
the direction of rear left or right

Indoor unit tubing Flare nut Pipings

o Tighten the flare nut with a wrench.

Drain hose
Spanner (fixed)

Flare nut

Torque wrench

Indoor Units
2. Tape the tubing, drain hose and the connecting Connection pipe
cable. Be sure that the drain hose is located at
Indoor unit tubing
the lowest side of the bundle. Locating at the
upper side can cause drain pan to overflow o When extending the drain hose at the indoor
inside the unit. unit, install the drain pipe.

Drain pipe

Loop Indoor unit drain hose

Vinyl tape(narrow)
Gas side piping Adhesive
Connecting
cable
4. Wrap the insulation material around the con-
Liquid side piping
Drain hose necting portion.
o Overlap the connecting pipe insulation material
and the indoor unit pipe insulation material. Bind
CAUTION: If the drain hose is routed them together with vinyl tape so that there is no
inside the room, insulate the hose with gap.
an insulation material* so that dripping
from "sweating"(condensation) will not
damage furniture or floors. Plastic bands Insulation material
*Foamed polyethylene or equivalent is
recommended.

ART COOL Gallery _ 15


10. Installation
CAUTION: Installation Information
For right piping. Follow the instruction below.

Good case
• Press on the upper side of clamp and unfold the tubing to downward slowly.
Indoor Units

Bad case
• Following bending type from left to right may cause damage to the turbing.

10.5 Drain Piping


1) To check the drainage. 2) Drain piping
• Pour a glass of water on the evaporator. • The drain hose should point downward for easy
• Ensure the water flows through the drain hose of drain flow. Downward slope
the indoor unit without any leakage and goes out
the drain exit.

• Do not make drain piping.

Accumulated Tip of drain hose


Do not raise dipped in water
drain water
Less than
Air 50mm gap

Water
Water Water leakage
Waving Ditch
leakage leakage

16 _ ART COOL Gallery


10. Installation
10.6 Panel Front Assembly
1. First, Check the side cover assembly
exactly, and fix the power cord in the
bottom groove of cover side left.

2. Assemble connecting lead wire with


controller, fix the upper part of panel

Indoor Units
front, and match the lower part of panel
front.

Panel Front
Connector

3. Screw up panel front, and suspend the


hook of panel front in the groove.

ART COOL Gallery _ 17


10. Installation
10.7 Connect the cable to the Indoor unit.
• Connect the cable to the indoor unit by connecting the wires to the terminals on the control board in-
dividually according to the outdoor unit connection. (Ensure that the color of the wires of the outdoor unit
and the terminal No. are the same as those of the indoor unit.)
The earth wire should be longer than the common wires.

[Type 1]

Terminal Block Indoor SODU B SODU A IDU B IDU A INT B INT A


1(L) 2(N) 3 4

INDOOR POWER INPUT

[Type 2]
Terminal Block Indoor SODU IDU INTERNET DRY1 DRY2 GND 12V Outdoor
1(L) 2(N) 3 4 Unit
B A - - B A - - - -
Indoor Units

INDOOR POWER INPUT


CAUTION
After the confirmation of the above conditions,
• When installing, refer to the circuit diagram on the prepare the wiring as follows:
Control Box of Indoor Unit. 1) Never fail to have separate power circuit specif-
• When installing, refer to the wiring diagram on the ically for the air conditioner. As for the method
Control Cover Inside Outdoor Unit. of wiring, follow the circuit
diagram posted on the inside of control cover.
2) The screw which fasten the wiring in the casing of
electrical fittings are liable to come loose from
CAUTION vibrations to which the unit is subjected during
• The above circuit diagram is subject to change with- the course of transportation. Check them and
make sure that they are all tightly fastened. (If they
out notice.
are loose, it could cause burn-out of the wires.)
• Be sure to connect wires according to the wiring dia-
3) Confirm the specification of power source.
gram.
4) Confirm that electrical capacity is sufficient.
• Connect the wires firmly, so that not to be pulled out
5) See to that the starting voltage is maintained at
easily.
more than 90 percent of the rated voltage
• Connect the wires according to color codes by refer- marked on the name plate.
ring the wiring diagram.
6) Confirm that the cable thickness is as specified
in the power source specification.
(Particularly note the relation between cable
length and thickness.
7) Always install an earth leakage circuit breaker
in a wet or moist area.
8) The following would be caused by voltage drop.
• Vibration of a magnetic switch, which will damage
the contact point, fuse breaking, disturbance of
the normal function of the overload.
9) The means for disconnection from a power
supply shall be incorporated in the fixed wiring
and have an air gap contact separation of at
least 3mm in each active(phase) conductor.

18 _ ART COOL Gallery


10. Installation

WIRED REMOTE CONTROLLER INSTALLATION


• Since the room temperature sensor is in the remote controller, the remote controller box should be installed in a place
away from direct sunlight, high humidity and direct supply of cold air to maintain proper space temperature.
Install the remote controller about 5ft(1.5m) above the floor in an area with good air circulation at an average tempera-
ture.
Do not install the remote controller where it can be affected by:
- Drafts, or dead spots behind doors and in corners.
- Hot or cold air from ducts.
- Radiant heat from sun or appliances.
- Concealed pipes and chimneys.
- Uncontrolled areas such as an outside wall behind the remote controller.
- This remote controller is equipped with a seven segment LED. display. For proper display of the remote controller
LED's, the remote controller should be installed properly as shown in Fig.1.
(The standard height is 1.2~1.5 m from floor level.)

Indoor Units
Remote Controller
TEMP
yes

no
TEMP

Remote Controller

no
TEMP
5feet
Remote
Controller

(1.5meters)
no

Fig.1 Typical locations for remote controller

ART COOL Gallery _ 19


11. Accessories

Standard Accessories
Installation guide map Type "A" screws and
Name plastic anchors (Other)

Quantity 1 EA 4 SET
• Owner's manual
• Installation manual

Shape
Indoor Units

CAUTION
• Use only those accessories (Standard or optional) which have designated specifications.

20 _ ART COOL Gallery


Indoor unit
Ceiling & Floor / Ceiling Suspended
1. List of functions

2. Specifications

3. Dimensions

4. Piping Diagrams

5. Wiring Diagrams

6. Capacity Tables

7. Air Velocity and Temperature Distribution

8. Electric Characteristics

9. Sound Levels

10. Installation

11. Accessories
1. List of functions

ARNU09GVEA2, ARNU12GVEA2, URNU18GVJA2


Category Function
URNU24GVJA2, URNU36GVKA2, URNU48GVLA2
Air supply outlet 1
Airflow direction control(left & right) Manual
Airflow direction control(up & down) Auto
Auto swing(left & right) X
Auto swing(up & down) O
Air flow
Airflow steps(fan/cool/heat) 3/4/3
Chaos swing X
Chaos wind(auto wind) O
Jet cool(Power wind) O
Swirl wind -
Deodorizing filter X
Air purifying Plasma air purifier X
Prefilter(washable / anti-fungus) O
Drain pump X
E.S.P. control X
Installation

Indoor Units
Electric heater(operation) X
High ceiling operation O
Hot start O
Reliability Self diagnosis O
Soft dry operation O
Auto changeover O(Heat recovery)
Auto cleaning X
Auto operation(artificial intelligence) O(Heat pump or Cooling only)
Auto restart operation O
Child lock O
Convenience Forced operation O
Group control O
Sleep mode O
Timer(on/off) O
Timer(weekly) O
Two thermistor control O
Wide wired remote controller PQRCVSL0/PQRCVSL0QW
Deluxe wired remote controller PQRCUDS0(B/S)
Individual
Simple wired remote controller PQRCVCL0Q(W)
control
Wired remote controller(for hotel use) PQRCHCA0Q(W)
Wireless LCD remote control PQWRH(C)Q0FDB
Zone control -
CTIE -
Special Electro thermostat -
function kit Remote temperature sensor -
Group control wire PZCWRCG3
Dry contact PQDSA(1)/PQDSB(1)/PQDSBC/PQDSBNGCM1/PQDSBCGCD0

O : Applied X : Not applied – : No relation


Option : Model name & price are different according to options, and assembled in factory with main unit.
Accessory : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate
package.

Ceiling & Floor / Ceiling Suspended _ 1


2. Specifications

Type Ceiling & Floor


Model Unit ARNU09GVEA2 ARNU12GVEA2
kW 2.8 3.6
Cooling Capacity kcal/h 2,400 3,100
Btu/h 9,600 12,300
kW 3.2 4.0
Heating Capacity kcal/h 2,800 3,400
Btu/h 10,900 13,600
Casing - -
mm 900 x 490 x 200 900 x 490 x 200
Dimensions(WxHxD) Body
inch 35-7/16 x 19-9/32 x 7-7/8 35-7/16 x 19-9/32 x 7-7/8
Coil Rows x Columns x FPI 2 x 12 x 20 2 x 12 x 20
Face Area m2 0.10 0.10
Type Cross Flow Fan Cross Flow Fan
Motor Output x Number W 27 27
Running Current A 0.15 0.15
Fan Air Flow Rate(H / M / L) CMM 7.6 / 6.9 / 6.2 9.2 / 7.6 / 6.9
Indoor Units

cfm 268 / 243 / 219 325 / 268 / 244


Drive Direct Direct
Motor type BLDC BLDC
Temperature Control Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating
Sound Absorbing Thermal Insulation Material Foamed polystrene Foamed polystrene
Safety Device Fuse Fuse
Liquid Side mm(inch) Ø6.35(1/4) Ø6.35(1/4)
Pipe Connections Gas Side mm(inch) Ø12.7(1/2) Ø12.7(1/2)
Drain Pipe(Internal Dia.) mm(inch) 16(5/8) 16(5/8)
Net Weight kg(lbs) 13.7(30.2) 13.7(30.2)
Noise Level(Sound Press, 1m, H / M / L) dB(A) 36 / 32 / 28 38 / 36 / 30
1, 220-240, 50 1, 220-240, 50
Power Supply Ø, V, Hz
1, 220, 60 1, 220, 60
Refrigerant Control EEV EEV
Power cable mm2 CV1.5 x 3C CV1.5 x 3C
Transmission cable mm2 CVV-SB 1.0~1.5 x 2C CVV-SB 1.0~1.5 x 2C
Color Morning fog Morning fog
Notes:-
1. Capacities are based on the following conditions: Conversion Formula
Cooling • Indoor temp. 27°C[80.6°F]DB/ 19°C[66.2°F]WB kcal/h= kW x 860
• Outdoor temp. 35°C[95°F]DB/ 24°C[75.2°F]WB Btu/h = kW x 3412
• Interconnecting Piping Length 7.5m cfm = m3/min x 35.3
• Level Difference of Zero l/s = CMM x 1000/60
Heating • Indoor temp. 20°C[68°F]DB/ 15°C[59°F]WB
• Outdoor temp. 7°C[44.6°F]DB/ 6°C[42.8°F]WB
• Interconnecting Piping Length 7.5m
• Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve
6. Anechoic chamber conversion value is measured at 1 m downward from unit centre.
The values depends on the ambient conditions and values are normally higher in actual operation.

2 _ Ceiling & Floor / Ceiling Suspended


2. Specifications

Type Ceiling Suspended


Model Unit URNU18GVJA2 URNU24GVJA2
kW 5.6 7.1
Cooling Capacity kcal/h 4,800 6,100
Btu/h 19,100 24,200
kW 6.3 8.0
Heating Capacity kcal/h 5,400 6,900
Btu/h 21,500 27,300
Casing Galvanized Steel Plate+Painting Galvanized Steel Plate+Painting
mm 950 x 650 x 220 950 x 650 x 220
Dimensions(WxHxD) Body
inch 37-13/32 x 25-19/32 x 8-21/32 37-13/32 x 25-19/32 x 8-21/32
Coil Rows x Columns x FPI 3 x 14 x 19 3 x 14 x 19
Face Area m2 0.23 0.23
Type Sirocco Fan Sirocco Fan
Motor Output x Number W 60 60
Running Current A 0.30 0.30
Fan Air Flow Rate(H / M / L) CMM 16.0 / 14.0 /12.0 18.0 / 16.0 / 14.0

Indoor Units
cfm 565 / 495 / 424 636 / 565 / 495
Drive Direct Direct
Motor type BLDC BLDC
Temperature Control Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating
Sound Absorbing Thermal Insulation Material Foamed polystrene Foamed polystrene
Safety Device Fuse Fuse
Liquid Side mm(inch) Ø6.35(1/4) Ø9.52(3/8)
Pipe Connections Gas Side mm(inch) Ø12.7(1/2) Ø15.88(5/8)
Drain Pipe(Internal Dia.) mm(inch) 16(5/8) 16(5/8)
Net Weight kg(lbs) 24.6(54.2) 24.6(54.2)
Noise Level(Sound Press, 1m, H / M / L) dB(A) 42 / 40 / 37 43 / 41 / 39
1, 220-240, 50 1, 220-240, 50
Power Supply Ø, V, Hz
1, 220, 60 1, 220, 60
Refrigerant Control EEV EEV
Power cable mm2 CV1.5 x 3C CV1.5 x 3C
Transmission cable mm2 CVV-SB 1.0~1.5 x 2C CVV-SB 1.0~1.5 x 2C
Color Morning fog Morning fog

Notes:- Conversion Formula


1. Capacities are based on the following conditions:
Cooling • Indoor temp. 27°C[80.6°F]DB/ 19°C[66.2°F]WB kcal/h= kW x 860
• Outdoor temp. 35°C[95°F]DB/ 24°C[75.2°F]WB Btu/h = kW x 3412
• Interconnecting Piping Length 7.5m cfm = m3/min x 35.3
• Level Difference of Zero l/s = CMM x 1000/60
Heating • Indoor temp. 20°C[68°F]DB/ 15°C[59°F]WB
• Outdoor temp. 7°C[44.6°F]DB/ 6°C[42.8°F]WB
• Interconnecting Piping Length 7.5m
• Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve
6. Anechoic chamber conversion value is measured at 1 m downward from unit centre.
The values depends on the ambient conditions and values are normally higher in actual operation.

Ceiling & Floor / Ceiling Suspended _ 3


2. Specifications

Type Ceiling Suspended


Model Unit URNU36GVKA2 URNU48GVLA2
kW 10.6 14.1
Cooling Capacity kcal/h 9,100 12,100
Btu/h 36,200 48,100
kW 11.9 15.9
Heating Capacity kcal/h 10,200 13,200
Btu/h 40,600 51,200
Casing Galvanized Steel Plate Galvanized Steel Plate
mm 1350 x 650 x 220 1750 x 650 x 220
Dimensions(WxHxD) Body
inch 53-5/32 x 8-21/32 x 25-19/32 68-29/32 × 25-19/32 × 8-21/32
Coil Rows x Columns x FPI 3 x 14 x 17 3 x 14 x 17
Face Area m2 0.42 0.42
Type Sirocco Fan Sirocco Fan
Motor Output x Number W 43.1 x 2 81*2
Running Current A 0.7 0.88
Fan Air Flow Rate(H / M / L) CMM 24.6 / 23 / 21.4 35 / 32 / 30
Indoor Units

cfm 869 / 812 / 756 1236 / 1130 / 1060


Drive Direct Direct
Motor type BLDC BLDC
Temperature Control Microprocessor, Thermostat for cooling and heating Microprocessor, Thermostat for cooling and heating
Sound Absorbing Thermal Insulation Material Foamed polystrene Foamed polystrene
Safety Device Fuse Fuse
Liquid Side mm(inch) Ø9.52(3/8) Ø9.52(3/8)
Pipe Connections Gas Side mm(inch) Ø15.88(5/8) Ø15.88(5/8)
Drain Pipe(Internal Dia.) mm(inch) 16(5/8) 16(5/8)
Net Weight kg(lbs) 35(77.2) 45(99.2)
Noise Level(Sound Press, 1m, H / M / L) dB(A) 48 / 46 / 44 49 / 48 / 47
1, 220 ~ 240, 50 1, 220 ~ 240, 50
Power Supply Ø, V, Hz
1, 220, 60 1, 220, 60
Refrigerant Control EEV EEV
Power cable mm2 CV1.5 x 3C CV1.5 x 3C
Transmission cable mm2 VCTF-SB 1.0 ~ 1.5 × 2C VCTF-SB 1.0 ~ 1.5 × 2C
Color Morning fog Morning fog

Notes:- Conversion Formula


1. Capacities are based on the following conditions:
Cooling • Indoor temp. 27°C[80.6°F]DB/ 19°C[66.2°F]WB kcal/h= kW x 860
• Outdoor temp. 35°C[95°F]DB/ 24°C[75.2°F]WB Btu/h = kW x 3412
• Interconnecting Piping Length 7.5m cfm = m3/min x 35.3
• Level Difference of Zero l/s = CMM x 1000/60
Heating • Indoor temp. 20°C[68°F]DB/ 15°C[59°F]WB
• Outdoor temp. 7°C[44.6°F]DB/ 6°C[42.8°F]WB
• Interconnecting Piping Length 7.5m
• Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve
6. Anechoic chamber conversion value is measured at 1 m downward from unit centre.
The values depends on the ambient conditions and values are normally higher in actual operation.

4 _ Ceiling & Floor / Ceiling Suspended


Ceiling & Floor

ARNU09GVEA2
ARNU12GVEA2
(unit : mm)
Model W H D

ARNU09GVEA2
3. Dimensions

900 490 200


ARNU12GVEA2

(unit : mm)
Number Name Descripition
1 Liquid pipe ø6.35 Flare connection
2 Gas pipe ø12.7 Flare connection
3 Suction gille
4 Discharge grille
5 Suspension bracket
6 Right side drain hose hole
7 Left side drain hose hole
8 Wiring connection Slit hole
9 Piping connection Slit hole
10 Signal receiver & Operation indicator

Note
1. Unit should be installed in compliance with the installation manual
in the product box.
2. Unit shall be grounded in accordance with the local regulations or
applicable national codes.

※ Required space(unit:mm)
587 More than 200mm
More than 200mm

More than 200mm


273

More than 50mm More than 50mm


More than 200mm

76, Seongsan-dong, Changwon City, Gyeongnam,


641-713, Korea CHASSIS CODE: VE

Ceiling & Floor / Ceiling Suspended _ 5


Indoor Units
Indoor Units

Ceiling Suspended
URNU18GVJA2
URNU24GVJA2

(unit : mm)
Model W H D
3. Dimensions

URNU18GVJA2 950 650 220


URNU24GVJA2

(unit : mm)
Number Name Descripition
1 Liquid pipe ø6.35 Flare connection
2 Gas pipe ø12.7 Flare connection
3 Suction gille

6 _ Ceiling & Floor / Ceiling Suspended


4 Discharge grille
5 Suspension bracket
6 Right side drain hose hole
7 Left side drain hose hole
8 Wiring connection Slit hole
9 Piping connection Slit hole
10 Right side drain pipe connection Slit hole
11 Left side drain pipe connection Slit hole
Note
1. Unit should be installed in compliance with the installation manual
in the product box.
2. Unit shall be grounded in accordance with the local regulations or
applicable national codes.

More than 700lm


※ Required space(unit:mm)

More than 700mm More than 300mm

76, Seongsan-dong, Changwon City, Gyeongnam,


641-713, Korea CHASSIS CODE: VJ
Ceiling Suspended

URNU36GVKA2
URNU48GVLA2
(unit : mm)
Model W H D
URNU36GVKA2 1350 650 220
3. Dimensions

URNU48GVLA2 1750 650 220


B
(unit : mm)
A Number Name Descripition
1 Liquid pipe ø9.52 Flare connection
2 Gas pipe ø15.88 Flare connection
3 Suction gille
4 Discharge grille
5 Suspension bracket
6 Right side drain hose hole
7 Left side drain hose hole
8 Wiring connection Slit hole
9 Piping connection Slit hole
10 Right side drain pipe connection Slit hole
11 Left side drain pipe connection Slit hole
Note
1. Unit should be installed in compliance with the installation manual
in the product box.
2. Unit shall be grounded in accordance with the local regulations or
applicable national codes.

※ Required space(unit:mm) More than 700lm

Model unit (mm) A B


URNU36GVKA2 1350 1255
More than 300mm
URNU48GVLA2 1750 1655
More than 700mm

76, Seongsan-dong, Changwon City, Gyeongnam,


641-713, Korea CHASSIS CODE: VK/VL

Ceiling & Floor / Ceiling Suspended _ 7


Indoor Units
4. Piping Diagrams
VE Chassis
:Cooling
Heat Exchanger EEV :Heating
Filter
Th3 Th2
C.F.F. Filter

Th1 lndoor unit


Indoor Units

VJ Chassis
:Cooling
Heat Exchanger EEV :Heating
Filter
Th3 Th2
Sirocco Fan Filter

Th1 lndoor unit

Refrigerant pipe connection port diameter


[Unit: mm(inch)]
Model Gas Liquid
ARNU09GVEA2 Ø12.7(1/2) Ø6.35(1/4)
ARNU12GVEA2 Ø12.7(1/2) Ø6.35(1/4)
URNU18GVJA2 Ø12.7(1/2) Ø6.35(1/4)
URNU24GVJA2 Ø15.88(5/8) Ø9.52(3/8)

LOC. Description
Th1 Room thermistor
Th2 Pipe in thermistor
Th3 Pipe out thermistor

8 _ Ceiling & Floor / Ceiling Suspended


4. Piping Diagrams
VK/VL Chassis
:Cooling
Heat Exchanger EEV :Heating
Filter
Th3 Th2
Sirocco Fan Filter

Th1 lndoor unit

Indoor Units
Refrigerant pipe connection port diameter

Model Gas Liquid


URNU36GVKA2 Ø15.88(5/8) Ø9.52(3/8)

URNU48GVLA2 Ø15.88(5/8) Ø9.52(3/8)

LOC. Description
Th1 Room thermistor
Th2 Pipe in thermistor
Th3 Pipe out thermistor

Ceiling & Floor / Ceiling Suspended _ 9


5. Wiring Diagrams
VE Chassis
Indoor Units

CONNECTOR
SPEC. DESCRIPTION
NUMBER
CN-POWER AC power supply AC power line input for indoor controller
CN-MOTOR1 Fan motor output Motor output of BLDC
CN-MOTOR2 Fan motor output Motor output of BLDC
CN-PIPE/OUT Discharge pipe sensor Pipe out thermistor
CN-PIPE/IN Suction pipe sensor Pipe in thermistor
CN-ROOM Room sensor Room thermistor
CN-REMO Remote controller Remote control line
CN-FLOAT Float switch input Float switch sensing
CN-EEV EEV output EEV Control output
CN-OPTION Option pwb. Communication between main and option
CN-COM Communication Communication between indoor and outdoor
CN-D/PUMP Drain pump output AC Output for drain pump
CN-POWER AC power supply AC Power line input for indoor controller
CN-DISPLAY Display wire Display wire line
CN-DOOR Door lock switch Door lock switch line
CN-CC Dry contact Dry contact line

Dip Switch Setting Off On Remarks


SW3 GROUP Master Slave Group Control setting using Wired Remote Controller
Old Dry Contact Mode Setting
1. Variable : Auto/Manual Mode can be chosen by Wide wired
SW4 DRY CONTACT Variable Auto remote controller or Wireless remote controller
(When shipped from Factory → Manual Mode)
2. Auto : For Dry Contact, it is always Auto mode.
1. Duct model
-. OFF : Default(not operate continuosly )
-. ON : Fan operate continuosly
SW5 EXTRA 1 Off On 2. Cassette Model : No Function
3. Ceiling Suspended Model
-. OFF : Ceiling(default)
-. ON : Floor

CAUTION
For Multi V Model, Dip Switch 1,2,6,7,8 must be set OFF
That dip switch is used for the other model.

10 _ Ceiling & Floor / Ceiling Suspended


5. Wiring Diagrams
VJ Chassis

Indoor Units
CONNECTOR
SPEC. DESCRIPTION
NUMBER
CN-POWER AC power supply AC power line input for indoor controller
CN-MOTOR1 Fan motor output Motor output of BLDC
CN-MOTOR2 Fan motor output Motor output of BLDC
CN-PIPE/OUT Discharge pipe sensor Pipe out thermistor
CN-PIPE/IN Suction pipe sensor Pipe in thermistor
CN-ROOM Room sensor Room thermistor
CN-REMO Remote controller Remote control line
CN-FLOAT Float switch input Float switch sensing
CN-EEV EEV output EEV Control output
CN-OPTION Option pwb. Communication between main and option
CN-COM Communication Communication between indoor and outdoor
CN-D/PUMP Drain pump output AC Output for drain pump
CN-POWER AC power supply AC Power line input for indoor controller
CN-DISPLAY Display wire Display wire line
CN-DOOR Door lock switch Door lock switch line
CN-CC Dry contact Dry contact line
Dip Switch Setting Off On Remarks
SW3 GROUP Master Slave Group Control setting using Wired Remote Controller
Old Dry Contact Mode Setting
1. Variable : Auto/Manual Mode can be chosen by Wide wired
SW4 DRY CONTACT Variable Auto remote controller or Wireless remote controller
(When shipped from Factory → Manual Mode)
2. Auto : For Dry Contact, it is always Auto mode.
1. Duct model
-. OFF : Default(not operate continuosly )
-. ON : Fan operate continuosly
SW5 EXTRA 1 Off On 2. Cassette Model : No Function
3. Ceiling Suspended Model
-. OFF : Ceiling(default)
-. ON : Floor

CAUTION
For Multi V Model, Dip Switch 1,2,6,7,8 must be set OFF
That dip switch is used for the other model.

Ceiling & Floor / Ceiling Suspended _ 11


5. Wiring Diagrams
VK Chassis
Indoor Units

CONNECTOR
SPEC. DESCRIPTION
NUMBER
CN-POWER AC power supply AC power line input for indoor controller
CN-MOTOR1 Fan motor output Motor output of BLDC
CN-MOTOR2 Fan motor output Motor output of BLDC
CN-PIPE/OUT Discharge pipe sensor Pipe out thermistor
CN-PIPE/IN Suction pipe sensor Pipe in thermistor
CN-ROOM Room sensor Room thermistor
CN-REMO Remote controller Remote control line
CN-EEV EEV output EEV Control output
CN-OPTION Option pwb. Communication between main and option
CN-COM Communication Communication between indoor and outdoor
CN-POWER AC power supply AC Power line input for indoor controller
CN-DISPLAY Display wire Display wire line
CN-DOOR Door lock switch Door lock switch line
CN-CC Dry contact Dry contact line

Dip Switch Setting Off On Remarks


SW3 GROUP Master Slave Group Control setting using Wired Remote Controller
Old Dry Contact Mode Setting
1. Variable : Auto/Manual Mode can be chosen by Wide wired
SW4 DRY CONTACT Variable Auto remote controller or Wireless remote controller
(When shipped from Factory → Manual Mode)
2. Auto : For Dry Contact, it is always Auto mode.
1. Duct model
-. OFF : Default(not operate continuosly )
-. ON : Fan operate continuosly
SW5 EXTRA 1 Off On 2. Cassette Model : No Function
3. Ceiling Suspended Model
-. OFF : Ceiling(default)
-. ON : Floor

CAUTION
For Multi V Model, Dip Switch 1,2,6,7,8 must be set OFF
That dip switch is used for the other model.

12 _ Ceiling & Floor / Ceiling Suspended


5. Wiring Diagrams
VL Chassis

CN-PIPE/IN CN-PIPE/OUT CN-ROOM

PIPE IN PIPE OUT ROOM


THERMISTOR THERMISTOR THERMISTOR

Indoor Units
CONNECTOR
SPEC. DESCRIPTION
NUMBER
CN-POWER AC power supply AC power line input for indoor controller
CN-MOTOR1 Fan motor output Motor output of BLDC
CN-MOTOR2 Fan motor output Motor output of BLDC
CN-PIPE/OUT Discharge pipe sensor Pipe out thermistor
CN-PIPE/IN Suction pipe sensor Pipe in thermistor
CN-ROOM Room sensor Room thermistor
CN-REMO Remote controller Remote control line
CN-EEV EEV output EEV Control output
CN-OPTION Option pwb. Communication between main and option
CN-COM Communication Communication between indoor and outdoor
CN-POWER AC power supply AC Power line input for indoor controller
CN-DISPLAY Display wire Display wire line
CN-DOOR Door lock switch Door lock switch line
CN-CC Dry contact Dry contact line

Dip Switch Setting Off On Remarks


SW3 GROUP Master Slave Group Control setting using Wired Remote Controller
Old Dry Contact Mode Setting
1. Variable : Auto/Manual Mode can be chosen by Wide wired
SW4 DRY CONTACT Variable Auto remote controller or Wireless remote controller
(When shipped from Factory → Manual Mode)
2. Auto : For Dry Contact, it is always Auto mode.
1. Duct model
-. OFF : Default(not operate continuosly )
-. ON : Fan operate continuosly
SW5 EXTRA 1 Off On 2. Cassette Model : No Function
3. Ceiling Suspended Model
-. OFF : Ceiling(default)
-. ON : Floor

CAUTION
For Multi V Model, Dip Switch 1,2,6,7,8 must be set OFF
That dip switch is used for the other model.

Ceiling & Floor / Ceiling Suspended _ 13


6. Capacity Tables
6.1 Cooling Capacity
Cooling capacity

Indoor air temp. (DB/WB, °C)


Capacity Outdoor 20 23 26 27 28 30 32
Index air temp. 14 16 18 19 20 22 24
(DB, °C) TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.7 2.1
12 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.6 2.1
14 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.6 2.1
16 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.5 2.0
18 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.5 2.0
20 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.4 2.0
21 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.4 2.0
23 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.4 2.1 3.4 1.9
2.8 25 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.3 2.1 3.3 1.9
27 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.2 2.1 3.3 1.9
29 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.2 2.0 3.2 1.9
Indoor Units

31 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.1 2.0 3.2 1.8
33 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.1 2.0 3.1 1.8
35 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.0 1.9 3.1 1.8
37 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 2.9 2.0 3.0 1.9 3.0 1.8
39 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 2.9 2.0 2.9 1.9 3.0 1.7
10 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.8 2.6 4.3 2.8 4.7 2.7
12 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.8 2.6 4.3 2.8 4.7 2.7
14 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.8 2.6 4.3 2.8 4.6 2.7
16 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.8 2.6 4.3 2.8 4.6 2.6
18 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.8 2.6 4.3 2.8 4.5 2.6
20 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.8 2.6 4.3 2.8 4.4 2.5
21 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.8 2.6 4.3 2.8 4.4 2.5
23 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.8 2.6 4.3 2.8 4.3 2.5
3.6 25 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.8 2.6 4.2 2.7 4.3 2.5
27 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.8 2.6 4.1 2.6 4.2 2.4
29 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.8 2.6 4.1 2.6 4.2 2.4
31 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.8 2.6 4.0 2.6 4.1 2.4
33 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.8 2.6 4.0 2.5 4.0 2.3
35 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.8 2.6 3.9 2.5 4.0 2.3
37 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.7 2.6 3.8 2.4 3.9 2.3
39 2.4 2.1 2.9 2.3 3.4 2.5 3.6 2.6 3.7 2.5 3.7 2.4 3.8 2.2
10 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.7 4.3 7.4 4.3
12 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.7 4.3 7.3 4.2
14 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.7 4.3 7.2 4.2
16 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.7 4.3 7.1 4.1
18 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.7 4.3 7.0 4.1
20 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.7 4.3 6.9 4.0
21 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.7 4.3 6.8 4.0
23 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.7 4.3 6.7 3.9
5.6 25 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.6 4.3 6.6 3.9
27 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.4 4.2 6.6 3.8
29 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.4 4.1 6.5 3.8
31 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.3 4.1 6.4 3.7
33 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.2 4.0 6.3 3.7
35 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.0 3.9 6.2 3.6
37 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 5.8 4.1 5.9 3.8 6.1 3.6
39 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 5.7 4.0 5.8 3.8 6.0 3.5

14 _ Ceiling & Floor / Ceiling Suspended


6. Capacity Tables
Cooling capacity

Indoor air temp. (DB/WB, °C)


Capacity Outdoor 20 23 26 27 28 30 32
Index air temp. 14 16 18 19 20 22 24
(DB, °C) TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 8.5 5.5 9.3 5.4
12 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 8.5 5.5 9.2 5.4
14 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 8.5 5.5 9.1 5.3
16 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 8.5 5.5 9.0 5.2
18 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 8.5 5.5 8.8 5.2
20 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 8.5 5.5 8.7 5.1
21 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 8.5 5.5 8.7 5.1
23 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 8.5 5.5 8.5 5.0
7.1 25 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 8.4 5.4 8.4 4.9
27 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 8.2 5.3 8.3 4.9
29 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 8.1 5.2 8.2 4.8

Indoor Units
31 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 8.0 5.1 8.1 4.7
33 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 7.8 5.1 7.9 4.6
35 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.6 5.3 7.7 5.0 7.8 4.6
37 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.4 5.1 7.5 4.9 7.7 4.5
39 4.8 4.2 5.7 4.6 6.6 5.0 7.1 5.1 7.2 5.0 7.4 4.8 7.6 4.4
10 7.2 6.2 8.5 6.8 9.9 7.4 10.6 7.5 11.3 7.8 12.7 8.1 13.9 8.0
12 7.2 6.2 8.5 6.8 9.9 7.4 10.6 7.5 11.3 7.8 12.7 8.1 13.7 8.0
14 7.2 6.2 8.5 6.8 9.9 7.4 10.6 7.5 11.3 7.8 12.7 8.1 13.6 7.8
16 7.2 6.2 8.5 6.8 9.9 7.4 10.6 7.5 11.3 7.8 12.7 8.1 13.4 7.7
18 7.2 6.2 8.5 6.8 9.9 7.4 10.6 7.5 11.3 7.8 12.7 8.1 13.1 7.7
20 7.2 6.2 8.5 6.8 9.9 7.4 10.6 7.5 11.3 7.8 12.7 8.1 13.0 7.5
21 7.2 6.2 8.5 6.8 9.9 7.4 10.6 7.5 11.3 7.8 12.7 8.1 13.0 7.5
23 7.2 6.2 8.5 6.8 9.9 7.4 10.6 7.5 11.3 7.8 12.7 8.1 12.7 7.4
10.6 25 7.2 6.2 8.5 6.8 9.9 7.4 10.6 7.5 11.3 7.8 12.5 8.0 12.5 7.2
27 7.2 6.2 8.5 6.8 9.9 7.4 10.6 7.5 11.3 7.8 12.2 7.8 12.4 7.2
29 7.2 6.2 8.5 6.8 9.9 7.4 10.6 7.5 11.3 7.8 12.1 7.7 12.2 7.1
31 7.2 6.2 8.5 6.8 9.9 7.4 10.6 7.5 11.3 7.8 11.9 7.5 12.1 6.9
33 7.2 6.2 8.5 6.8 9.9 7.4 10.6 7.5 11.3 7.8 11.6 7.5 11.8 6.8
35 7.2 6.2 8.5 6.8 9.9 7.4 10.6 7.5 11.3 7.8 11.5 7.4 11.6 6.8
37 7.2 6.2 8.5 6.8 9.9 7.4 10.6 7.5 11.0 7.5 11.2 7.2 11.5 6.6
39 7.2 6.2 8.5 6.8 9.9 7.4 10.6 7.5 10.7 7.4 11.0 7.1 11.3 6.5
10 9.5 8.4 11.3 9.2 13.1 10.0 14.1 10.2 15.1 10.6 16.9 10.9 18.5 10.7
12 9.5 8.4 11.3 9.2 13.1 10.0 14.1 10.2 15.1 10.6 16.9 10.9 18.3 10.7
14 9.5 8.4 11.3 9.2 13.1 10.0 14.1 10.2 15.1 10.6 16.9 10.9 18.1 10.6
16 9.5 8.4 11.3 9.2 13.1 10.0 14.1 10.2 15.1 10.6 16.9 10.9 17.9 10.4
18 9.5 8.4 11.3 9.2 13.1 10.0 14.1 10.2 15.1 10.6 16.9 10.9 17.5 10.4
20 9.5 8.4 11.3 9.2 13.1 10.0 14.1 10.2 15.1 10.6 16.9 10.9 17.3 10.2
21 9.5 8.4 11.3 9.2 13.1 10.0 14.1 10.2 15.1 10.6 16.9 10.9 17.3 10.2
23 9.5 8.4 11.3 9.2 13.1 10.0 14.1 10.2 15.1 10.6 16.9 10.9 16.9 10.0
14.1 25 9.5 8.4 11.3 9.2 13.1 10.0 14.1 10.2 15.1 10.6 16.7 10.7 16.7 9.8
27 9.5 8.4 11.3 9.2 13.1 10.0 14.1 10.2 15.1 10.6 16.3 10.6 16.5 9.8
29 9.5 8.4 11.3 9.2 13.1 10.0 14.1 10.2 15.1 10.6 16.1 10.4 16.3 9.6
31 9.5 8.4 11.3 9.2 13.1 10.0 14.1 10.2 15.1 10.6 15.9 10.2 16.1 9.4
33 9.5 8.4 11.3 9.2 13.1 10.0 14.1 10.2 15.1 10.6 15.5 10.2 15.7 9.2
35 9.5 8.4 11.3 9.2 13.1 10.0 14.1 10.2 15.1 10.6 15.3 10.0 15.5 9.2
37 9.5 8.4 11.3 9.2 13.1 10.0 14.1 10.2 14.7 10.2 14.9 9.8 15.3 9.0
39 9.5 8.4 11.3 9.2 13.1 10.0 14.1 10.2 14.3 10.0 14.7 9.6 15.1 8.8
Notes:
TC: Total Capacity(kW), SHC: Sensible Heat Capacity(kW) 2. Refer to Capacity Correction Factor in the outdoor unit PDB for
1. Capacity tables show the representative value of conditions the actual performance data of each indoor unit and outdoor unit
which may occur. combination.

Ceiling & Floor / Ceiling Suspended _ 15


6. Capacity Tables
6.2 Heating Capacity Heating capacity

Outdoor air Indoor air temp. (DB, °C)


Capacity temp. 16 18 20 21 22 24
Index TC TC TC TC TC TC
DB(°C) WB(°C)
kW kW kW kW kW kW
-24.8 -25.0 1.9 1.9 1.8 1.8 1.8 1.8
-21.8 -22.0 2.2 2.2 2.2 2.2 2.2 2.2
-19.8 -20.0 2.4 2.4 2.3 2.3 2.3 2.3
-18.8 -19.0 2.4 2.4 2.4 2.4 2.4 2.4
-16.7 -17.0 2.5 2.5 2.5 2.5 2.5 2.5
-14.7 -15.0 2.7 2.7 2.6 2.6 2.6 2.6
-12.6 -13.0 2.8 2.8 2.8 2.8 2.7 2.7
-10.5 -11.0 2.9 2.9 2.9 2.9 2.9 2.8
-9.5 -10.0 3.0 3.0 2.9 2.9 2.9 2.8
-8.5 -9.1 3.0 3.0 3.0 3.0 3.0 2.8
-7.0 -7.6 3.1 3.1 3.1 3.1 3.0 2.8
2.8 -5.0 -5.6 3.2 3.2 3.2 3.1 3.0 2.8
-3.0 -3.7 3.4 3.3 3.2 3.1 3.0 2.8
0.0 -0.7 3.4 3.3 3.2 3.1 3.0 2.8
3.0 2.2 3.5 3.4 3.2 3.1 3.0 2.8
Indoor Units

5.0 4.1 3.6 3.4 3.2 3.1 3.0 2.8


7.0 6.0 3.6 3.4 3.2 3.1 3.0 2.8
9.0 7.9 3.6 3.4 3.2 3.1 3.0 2.8
11.0 9.8 3.6 3.4 3.2 3.1 3.0 2.8
13.0 11.8 3.6 3.4 3.2 3.1 3.0 2.8
15.0 13.7 3.6 3.4 3.2 3.1 3.0 2.8
-24.8 -25.0 2.3 2.3 2.3 2.3 2.3 2.3
-21.8 -22.0 2.8 2.8 2.8 2.8 2.8 2.8
-19.8 -20.0 2.9 2.9 2.9 2.9 2.9 2.9
-18.8 -19.0 3.0 3.0 3.0 3.0 3.0 3.0
-16.7 -17.0 3.1 3.1 3.1 3.1 3.1 3.1
-14.7 -15.0 3.3 3.3 3.3 3.3 3.3 3.3
-12.6 -13.0 3.5 3.4 3.4 3.4 3.4 3.4
-10.5 -11.0 3.6 3.6 3.6 3.6 3.6 3.5
-9.5 -10.0 3.7 3.7 3.7 3.7 3.7 3.5
-8.5 -9.1 3.8 3.8 3.7 3.7 3.7 3.5
3.6 -7.0 -7.6 3.9 3.9 3.9 3.8 3.7 3.5
-5.0 -5.6 4.0 4.0 4.0 3.9 3.7 3.5
-3.0 -3.7 4.2 4.1 4.0 3.9 3.7 3.5
0.0 -0.7 4.3 4.1 4.0 3.9 3.7 3.5
3.0 2.2 4.4 4.3 4.0 3.9 3.7 3.5
5.0 4.1 4.5 4.3 4.0 3.9 3.7 3.5
7.0 6.0 4.5 4.3 4.0 3.9 3.7 3.5
9.0 7.9 4.5 4.3 4.0 3.9 3.7 3.5
11.0 9.8 4.5 4.3 4.0 3.9 3.7 3.5
13.0 11.8 4.5 4.3 4.0 3.9 3.7 3.5
15.0 13.7 4.5 4.3 4.0 3.9 3.7 3.5
-24.8 -25.0 3.6 3.6 3.6 3.6 3.6 3.6
-21.8 -22.0 4.4 4.4 4.4 4.4 4.4 4.4
-19.8 -20.0 4.6 4.6 4.6 4.6 4.6 4.6
-18.8 -19.0 4.8 4.7 4.7 4.7 4.7 4.7
-16.7 -17.0 5.0 5.0 5.0 4.9 4.9 4.9
-14.7 -15.0 5.2 5.2 5.2 5.2 5.2 5.2
-12.6 -13.0 5.5 5.4 5.4 5.4 5.4 5.4
-10.5 -11.0 5.7 5.7 5.7 5.7 5.7 5.5
-9.5 -10.0 5.8 5.8 5.8 5.8 5.8 5.5
-8.5 -9.1 5.9 5.9 5.9 5.9 5.9 5.5
-7.0 -7.6 6.1 6.1 6.1 6.0 5.9 5.5
5.6 -5.0 -5.6 6.3 6.3 6.3 6.1 5.9 5.5
-3.0 -3.7 6.6 6.5 6.3 6.1 5.9 5.5
0.0 -0.7 6.7 6.5 6.3 6.1 5.9 5.5
3.0 2.2 6.9 6.7 6.3 6.1 5.9 5.5
5.0 4.1 7.0 6.7 6.3 6.1 5.9 5.5
7.0 6.0 7.1 6.7 6.3 6.1 5.9 5.5
9.0 7.9 7.1 6.7 6.3 6.1 5.9 5.5
11.0 9.8 7.1 6.7 6.3 6.1 5.9 5.5
13.0 11.8 7.1 6.7 6.3 6.1 5.9 5.5
15.0 13.7 7.1 6.7 6.3 6.1 5.9 5.5

16 _ Ceiling & Floor / Ceiling Suspended


6. Capacity Tables
Heating capacity

Outdoor air Indoor air temp. (DB, °C)


Capacity temp. 16 18 20 21 22 24
Index TC TC TC TC TC TC
DB(°C) WB(°C)
kW kW kW kW kW kW
-24.8 -25.0 4.6 4.6 4.6 4.6 4.6 4.6
-21.8 -22.0 5.6 5.6 5.6 5.6 5.6 5.5
-19.8 -20.0 5.9 5.9 5.9 5.9 5.9 5.8
-18.8 -19.0 6.0 6.0 6.0 6.0 6.0 6.0
-16.7 -17.0 6.3 6.3 6.3 6.3 6.3 6.3
-14.7 -15.0 6.6 6.6 6.6 6.6 6.6 6.6
-12.6 -13.0 6.9 6.9 6.9 6.9 6.9 6.9
-10.5 -11.0 7.2 7.2 7.2 7.2 7.2 7.0
-9.5 -10.0 7.4 7.4 7.3 7.3 7.3 7.0
-8.5 -9.1 7.5 7.5 7.5 7.5 7.5 7.0
7.1 -7.0 -7.6 7.7 7.7 7.7 7.7 7.5 7.0
-5.0 -5.6 8.0 8.0 8.0 7.7 7.5 7.0
-3.0 -3.7 8.4 8.2 8.0 7.7 7.5 7.0
0.0 -0.7 8.6 8.3 8.0 7.7 7.5 7.0
3.0 2.2 8.8 8.5 8.0 7.7 7.5 7.0
5.0 4.1 8.9 8.5 8.0 7.7 7.5 7.0

Indoor Units
7.0 6.0 9.0 8.5 8.0 7.7 7.5 7.0
9.0 7.9 9.0 8.5 8.0 7.7 7.5 7.0
11.0 9.8 9.0 8.5 8.0 7.7 7.5 7.0
13.0 11.8 9.0 8.5 8.0 7.7 7.5 7.0
15.0 13.7 9.0 8.5 8.0 7.7 7.5 7.0
-24.8 -25.0 6.9 6.9 6.8 6.8 6.8 6.8
-21.8 -22.0 8.3 8.3 8.3 8.3 8.3 8.2
-19.8 -20.0 8.8 8.8 8.7 8.7 8.7 8.6
-18.8 -19.0 9.0 8.9 8.9 8.9 8.9 8.9
-16.7 -17.0 9.4 9.4 9.4 9.3 9.3 9.3
-14.7 -15.0 9.9 9.9 9.8 9.8 9.8 9.8
-12.6 -13.0 10.3 10.3 10.3 10.3 10.2 10.2
-10.5 -11.0 10.8 10.8 10.7 10.7 10.7 10.4
-9.5 -10.0 11.0 11.0 10.9 10.9 10.9 10.4
-8.5 -9.1 11.2 11.2 11.1 11.1 11.1 10.4
10.6 -7.0 -7.6 11.5 11.5 11.5 11.4 11.1 10.4
-5.0 -5.6 12.0 11.9 11.9 11.5 11.1 10.4
-3.0 -3.7 12.5 12.2 11.9 11.5 11.1 10.4
0.0 -0.7 12.7 12.3 11.9 11.5 11.1 10.4
3.0 2.2 13.1 12.7 11.9 11.5 11.1 10.4
5.0 4.1 13.3 12.7 11.9 11.5 11.1 10.4
7.0 6.0 13.4 12.7 11.9 11.5 11.1 10.4
9.0 7.9 13.4 12.7 11.9 11.5 11.1 10.4
11.0 9.8 13.4 12.7 11.9 11.5 11.1 10.4
13.0 11.8 13.4 12.7 11.9 11.5 11.1 10.4
15.0 13.7 13.4 12.7 11.9 11.5 11.1 10.4
-24.8 -25.0 9.2 9.2 9.1 9.1 9.1 9.1
-21.8 -22.0 11.1 11.1 11.1 11.1 11.1 11.0
-19.8 -20.0 11.7 11.7 11.6 11.6 11.6 11.6
-18.8 -19.0 12.0 11.9 11.9 11.9 11.9 11.9
-16.7 -17.0 12.5 12.5 12.5 12.4 12.4 12.4
-14.7 -15.0 13.2 13.2 13.1 13.1 13.1 13.0
-12.6 -13.0 13.8 13.7 13.7 13.7 13.6 13.6
-10.5 -11.0 14.4 14.4 14.3 14.3 14.3 13.9
-9.5 -10.0 14.7 14.7 14.6 14.6 14.6 13.9
-8.5 -9.1 14.9 14.9 14.9 14.9 14.9 13.9
14.1 -7.0
-5.0
-7.6
-5.6
15.4
16.0
15.3
15.9
15.3
15.9
15.2
15.4
14.9
14.9
13.9
13.9
-3.0 -3.7 16.7 16.3 15.9 15.4 14.9 13.9
0.0 -0.7 17.0 16.5 15.9 15.4 14.9 13.9
3.0 2.2 17.5 16.9 15.9 15.4 14.9 13.9
5.0 4.1 17.7 16.9 15.9 15.4 14.9 13.9
7.0 6.0 17.9 16.9 15.9 15.4 14.9 13.9
9.0 7.9 17.9 16.9 15.9 15.4 14.9 13.9
11.0 9.8 17.9 16.9 15.9 15.4 14.9 13.9
13.0 11.8 17.9 16.9 15.9 15.4 14.9 13.9
15.0 13.7 17.9 16.9 15.9 15.4 14.9 13.9
Notes:
TC: Total Capacity(kW) 3. In accordance with operation limits of outdoor unit, applicable range of
1. Capacity tables show the representative value of conditions which may occur. capacity tables is different.
2. is shown as reference. When selecting the outdoor units, avoid the 4. Refer to Capacity Correction Factor in the outdoor unit PDB for the actual
outdoor air temperature range shown by . performance data of each indoor unit and outdoor unit combination.

Ceiling & Floor / Ceiling Suspended _ 17


7. Air Velocity and Temperature Distribution
ARNU09GVEA2
■ Ceiling
Cooling Heating
Discharge angle:50° Discharge angle:60°

Air velocity [m/s] Air velocity [m/s]


1.5 1.0
2.7m 2.7m
0.5 0.5
1.0

0.5
0.5
1.0 1.0
0.5
1.0
0.5 2m 1.0 2m
0.5
1.0

1.0
0.5 0.5

1m 1m

0.5
0.5
1.0 0.5
1.0 0.5
0m 0m
5m 4m 3m 2m 1m 0m 5m 4m 3m 2m 1m 0m

Temperature [°C] Temperature [°C]


15.0 14.0 2.7m 2.7m
Indoor Units

17.0 28.0 32.0 30.0


17.0 30.0

32.0
16.0

.0
13.0 13.0

32

42
44.0
17.0
18.0

15.0

.0
17.0 42.0
17.0

32
15.0

.5
2m

34
38.0 2m

.0
32.5
18.0

17.0

32.0
18.0

1m 1m

30.0
18.0 18.0 30.0 .0
28.0 3434.0
0m 0m
5m 4m 3m 2m 1m 0m 5m 4m 3m 2m 1m 0m

ARNU09GVEA2
■ Floor
Cooling Heating
Discharge angle:45° Discharge angle:50°

Air velocity [m/s] Air velocity [m/s]


0.5 2.7m 0.5 2.7m
0.5

1.0
0.5
0.5

0.5

0.5 2m 2m
0.5
0.5

1.0
1.0

0.5
1.5
1.0

0.5 2.0
0.5

1m 1m
1.5

1.0
0.4

0.4
0.5

0.2 0.4

0.5 0.5
0.
0.4 5 0.5
1.0
0.5
0m 0m
5m 4m 3m 2m 1m 0m 5m 4m 3m 2m 1m 0m

Temperature [°C] Temperature [°C]


2.7m 2.7m
0
36.0

.0
18. 32 35
.0 38.0

35.1
14.8
2m 2m
14.8

38.0

0
16.
38.0

1m 1m
14.8
42.0
18.0

.0

35.1
40
35
36.0

0
18.
.1

18.0 34.0
35.1
35.1
34.0
34.0
0m 0m
5m 4m 3m 2m 1m 0m 5m 4m 3m 2m 1m 0m

18 _ Ceiling & Floor / Ceiling Suspended


7. Air Velocity and Temperature Distribution
ARNU12GVEA2
■ Ceiling
Cooling Heating
Discharge angle:50° Discharge angle:60°

Air velocity [m/s] Air velocity [m/s]


1.0 2.7m 2.7m
0.5 26.0 28.0
1.5
1.0 2.5 1.0 30.0 30.0
0.5 1.0 1.0
1.5 44.0
1.0 0.5
0.5 2m 26.0 38.0 2m
28.0 30.0
1.0

1m 1m
0.5
26.0
28.0
30.0
1.0
1.0 0.5
0.5 1.5 24.0 32.0
0m 0m
5m 4m 3m 2m 1m 0m 5m 4m 3m 2m 1m 0m

Temperature [°C] Temperature [°C]


2.7m

Indoor Units
14.0 14.0 2.7m
15.0 26.0 28.0
17.0 16.0 15.0 13.0 13.0
30.0 30.0
18.0
17.0 17.0 44.0
2m 26.0 38.0 2m
17.0 28.0 30.0

1m 1m
26.0
17.0 17.0 28.0
30.0
16.0
17.0 16.0 18.0 24.0 32.0
0m 0m
5m 4m 3m 2m 1m 0m 5m 4m 3m 2m 1m 0m

ARNU12GVEA2
■ Floor
Cooling Heating
Discharge angle:50° Discharge angle:60°

Air velocity [m/s] Air velocity [m/s]


2.7m 2.7m
1.5 1.
5

1.0
0.

0.4 1.0 0
0.5

2.0 0.5
0.5
1.5 2m 1.5 2m
0.4
0.5
1.0
1.0

1.0
1.0
0.5

0.5
0.5

1.5
1.5
0.5

2.5

1m
0.5

1.0 1m
0.4
0.5

1.5 1.5

1.5
0.4
0.5 0.5
0.5 1.0 0.5
1.0
1.0

0m 0m
5m 4m 3m 2m 1m 0m 5m 4m 3m 2m 1m 0m

Temperature [°C] Temperature [°C]

16.0 2.7m 36.0 2.7m


38.0

.0
18.0 16.0 34.0 38 38
36.0 .0
15.0

35.4
16.8
2m 2m
38.0
36.0 35.4
35.4
36.0

14.0
42.0

1m 1m
16
.0

40.0
42.035.4

13.0 15.0
35

42

16
.4

.0
.0

16.8 17.0
36
.0
.0
20 19.0 16.8
18.0
35.4 34.0
34.0
0m 0m
5m 4m 3m 2m 1m 0m 5m 4m 3m 2m 1m 0m

Ceiling & Floor / Ceiling Suspended _ 19


7. Air Velocity and Temperature Distribution
URNU18GVJA2
■ Ceiling
Cooling Heating
Discharge angle:50° Discharge angle:60°

Air velocity [m/s] Air velocity [m/s]


1.0 2.7m 3.0 1.5 2.7m
3.0 3.0

3.0
4.0 4.0 1.5 3.0
1.5

1.5
1.5 3.0 3.5 1.5

1.5
1.5
1.0 1.5
2m 2m

1.5 1.5

1m 1m

1.5
1.0

1.5 1.5
1.5
1.0

1.5
0m 0m
5m 4m 3m 2m 1m 0m 5m 4m 3m 2m 1m 0m

Temperature [°C] Temperature [°C]


15 14.0 2.7m
13.0 14.0 13.0 2.7m
Indoor Units

.0 40.0

40.0
16.0 34.0 38.0 40.0
.0

18.0

14.0 17.0 42.0


16

17.0 42.0
17.0

34.0

.0
36.0

32
2m 2m

36.0
36.0
16.0

30.0
38.0

18.0
1m 1m

36.0
.0

36

.0
17

19
.0
19

28.0
.0

0m 0m
5m 4m 3m 2m 1m 0m 0m
5m 4m 3m 2m 1m

URNU24GVJA2
■ Ceiling
Cooling Heating
Discharge angle:50° Discharge angle:60°
g g

Air velocity [m/s] Air velocity [m/s]


2.0 2.0 2.7m
3.0 1.0 0.5 2.7m
2.0

3.0 3.5 3.0 1.0 1.0 1.0


6.0

1.0 3.0 4
2.0 .5 5.0 1.0 1.0
1.0
1.0

1.0 2m
2m
0.5
2.0 1.0
1.0

1m
1m

2.0
1.0

1.0
1.0
1.0

0m
0m
5m 4m 3m 2m 1m 0m
5m 4m 3m 2m 1m 0m

Temperature [°C] Temperature [°C]


40.0 40.0 2.7m
.0 14.0 2.7m 34.0 38.0 40.0
13.0

15.0 38.0
18 17.0 .0
13.0 36.0 42.0 42
.0

34.0
38.0
18.0

36

17.0 15.0 17.0 36.0 38.0

2m
2m
36.0

16.0
18.0
1m
1m

16 17.0
36 2.0

.0 .0 36.0
.0

19 18 32.0
3

.0 0m
0m
5m 4m 3m 2m 1m 0m
5m 4m 3m 2m 1m 0m

20 _ Ceiling & Floor / Ceiling Suspended


7. Air Velocity and Temperature Distribution
URNU36GVKA2
■ Ceiling
Cooling Heating
Discharge angle:10° Discharge angle:45°

Air velocity [m/s] Air velocity [m/s]

2.7m 2.7m
3 0.25
2.5 2
1 1.5 1 4
0.5
2m 0.5 0.25 2m 3.5
3
0.25 1
2.5
1 2 0.5
1m 1m 1.5
0.5

0.25 0.25
0m 0m
0m 1m 2m 3m 4m 5m 6m 7m 8m 0m 1m 2m 3m 4m 5m 6m 7m 8m

Temperature [°C] Temperature [°C]

Indoor Units
2.7m 15 17 2.7m
19
21 16
23 25
32
2m 2m 30
27 18 16
28
26

1m 24 20 14
1m 22
12
31
29
0m 12
0m
0m 1m 2m 3m 4m 5m 6m 7m 8m 0m 1m 2m 3m 4m 5m 6m 7m 8m

URNU48GVLA2
■ Ceiling
Cooling Heating
Discharge angle:10° Discharge angle:45°

Air velocity [m/s] Air velocity [m/s]


2 .7 m
2.7m 3 0.25 2.7m
2.5 0.5
2 1
0.5 3.5 1
2m 0.5 3 2m 0.5
2m
1.5 2.5
0.25 0.25
2 1.5
1m
1m
1m

0.5
0.25
0.25 0m
0m 0m 1m 2m 3m 4m 5m 6m
0m
0m 1m 2m 3m 4m 5m 6m 7m 8m 0m 1m 2m 3m 4m 5m 6m 7m 8m

Temperature [°C] Temperature [°C]


2.7m
2 . 7m 2 .7 m
14 16 18 20 18
22 2m 20
32 18
24 30
2m 2m
28
26 22
26 1m 14
24
1m 1m 12 16

0m
30 28 0m 1m 2m 3m 4m 5m 6m
0m 0m
0m 1m 2m 3m 4m 5m 6m 7m 8m
0m 1m 2m 3m 4m 5m 6m 7m 8m

Ceiling & Floor / Ceiling Suspended _ 21


8. Electric Characteristics
Units Power Supply IFM Input(W)
Model Type Hz Volts Voltage Range MCA MFA kW FLA Cooling Heating
ARNU09GVEA2 VE 0.22 15 0.027 0.17 30 30
ARNU12GVEA2 VE 0.22 15 0.027 0.17 30 30
Max:264
URNU18GVJA2 VJ 50 220 - 240 0.43 15 0.060 0.35 63 63
Min:198
URNU24GVJA2 VJ 0.43 15 0.060 0.35 63 63
URNU36GVKA2 VK 0.88 15 0.086 0.71 140 140
URNU48GVLA2 VL 1.10 15 0.162 0.88 190 190
ARNU09GVEA2 VE 0.22 15 0.027 0.17 30 30
ARNU12GVEA2 VE 0.22 15 0.027 0.17 30 30
URNU18GVJA2 VJ Max:242 0.43 15 0.060 0.35 63 63
60 220
Min:198
URNU24GVJA2 VJ 0.43 15 0.060 0.35 63 63
URNU36GVKA2 VK 0.88 15 0.086 0.71 140 140
URNU48GVLA2 VL 1.10 15 0.162 0.88 190 190
Indoor Units

Symbols:
MCA: Minimum Circuit Amperes (A)
MFA : Maximum Fuse Amperes(see note 5)
kW : Fan Motor Rated Output(kW)
FLA : Full Load Amperes(A)
IFM : Indoor Fan Motor

Note :
1. Voltage Range
Units are suitable for use on electrical system where voltage supplied to unit terminals is not below or above the
listed range limits.
2. Maximum allowable voltage unbalance between phase is 2%.
3. MCA/MFA
MCA = 1.25 x FLA
MFA ≤ 4 x FLA
( Next lower standard fuse rating. Minimum 15A)
4. Select wire size based on the MCA.
5. Instead of fuse, use Circuit Breaker.

22 _ Ceiling & Floor / Ceiling Suspended


9. Sound Levels
Overall
Notes:
1. Sound measured at each 1m away from the front and bottom of the unit
2. Operating condition
1m - Power source : 220-240V 50Hz / 220V 60Hz
- Cooling : Indoor temperature (27°C DB, 19°C WB),
Outdoor temperature (35°C DB, 24°C WB)

1m
- Heating : Indoor temperature (20°C DB, 15°C WB),
Microphone Outdoor temperature (7°C DB, 6°C WB)
3. Reference accoustic pressure 0dB = 20μPa
4. Sound level will vary depending on a range of factors such as
❈ Measuring place : Anechoic chamber the construction(acoustic absorption coefficient) of particular
room in which the equipment in installed.

Sound Levels dB(A) Sound Levels dB(A)


Model Model
H M L
H M L
URNU18GVJA2 42 40 37
ARNU09GVEA2 36 32 28
URNU24GVJA2 43 41 39
ARNU12GVEA2 38 36 30
URNU36GVKA2 48 46 44

Sound Pressure Level URNU48GVLA2 49 48 47

Indoor Units
ARNU09GVEA2 ARNU12GVEA2 URNU18GVJA2
80 80
80

70 70 70

Octave Band Sound Pressure Level (0dB = 20μPa)


Octave Band Sound Pressure Level (0dB = 20μPa)

Octave Band Sound Pressure Level (0dB = 20μPa)

NC-65 NC-65 NC-65


60 60 60

NC-60 NC-60 NC-60

NC-55 NC-55 NC-55


50 50 50

NC-50 NC-50 NC-50

NC-45 NC-45 NC-45


40 40 40

NC-40 NC-40 NC-40

NC-35 NC-35 NC-35


30 30 30
NC-30 NC-30 NC-30

20 NC-25 NC-25 20 NC-25


20
Approximate Approximate Approximate
NC-20 NC-20 NC-20
Hearing Hearing Hearing
Threshold NC-15 Threshold Threshold
NC-15 NC-15
10 10 10
63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

URNU24GVJA2 URNU36GVKA2 URNU48GVLA2


80 80 80

70 70 70
Octave Band Sound Pressure Level (0dB = 20μPa)

Octave Band Sound Pressure Level (0dB = 20μPa)

Octave Band Sound Pressure Level (0dB = 20μPa)

NC-65 NC-65 NC-65


60 60 60

NC-60 NC-60 NC-60

NC-55 NC-55 NC-55


50 50 50

NC-50 NC-50 NC-50

NC-45 NC-45 NC-45


40 40 40

NC-40 NC-40 NC-40

NC-35 NC-35 NC-35


30 30 30

NC-30 NC-30 NC-30

20 NC-25 20 NC-25 20 NC-25

Approximate Approximate Approximate


NC-20 NC-20 NC-20
Hearing Hearing Hearing
Threshold NC-15 Threshold NC-15 Threshold NC-15
10 10 10
63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000

Ceiling & Floor / Ceiling Suspended _ 23


10. Installation
• Please read this instruction sheet completely before installing the product.
• When the power cord is damaged, replacement work shall be performed by authorized personnel only.
• Installation work must be performed in accordance with the national wiring standards by authorized personnel only.

10.1 Features
10.1.1 VE Chassis

Vertical louver Horizontal louver

Air outlet vent


Indoor Units

Air filters
(behind front panel)
Air inlet vent

24 _ Ceiling & Floor / Ceiling Suspended


10. Installation
10.1.2 VJ Chassis

Air Discharge

Signal Receptor
Right Side Cover

Air Filter

Indoor Units
Left Side Cover

Inlet Grill

Drain hose

Ceiling & Floor / Ceiling Suspended _ 25


10. Installation
10.1.3 VK/VL Chassis

Air Discharge

Right
Side Cover

Air Filter Signal Receptor


Indoor Units

Inlet Grill Left


Side Cover

Drain hose

26 _ Ceiling & Floor / Ceiling Suspended


10. Installation
VE Chassis
10.2 Installation Map

NOTICE Installation parts you should purchase.

There should be no gap between


Ceiling Mounting the ceiling and the unit.

Sleeve

Indoor Units
Bushing-Sleeve
Putty(Gum Type Sealer)
Bend the pipe as closely
More than
on the wall as possible,
200mm
More than 50mm but be careful that it
(Left and right doesn't break.
are identical)

Wall Mounting

More than
200mm
(Left and right
are identical) Vinyl tape (Wide)
• To carry out the drainage
test, remove the air filters
and pour water into the heat
More than 50mm exchanger.
• Apply after carrying out a
drainage test.

Saddle

Ceiling & Floor / Ceiling Suspended _ 27


10. Installation
10.3 Select the best Location
Indoor unit
More than 200mm
1. Do not have any heat or steam near the unit.
2. Select a place where there are no obstacles in front More than 200mm
of the unit.
3. Make sure that condensation drainage can be conve-
niently routed away.
More than 50mm
4. Do not install near a doorway.
5. Ensure that the interval between a wall and the left
(or right) of the unit is more than 200mm. The unit More than 200mm
should be installed as low as possible on the wall,
allowing a minimum of 500mm from floor.
6. Use a stud finder to locate studs to prevent unneces-
sary damage to the wall.
Indoor Units

More than 50mm


More than 200mm

9.4 Preparing Work for Installation


Open panel front
1. Remove the five screws. 2 Claw
2. Release the claws in the 3 places indicated.
3. Pull up the Front Panel.
Cover pipe and cover side remove
1. Pull up the side cover of desired connecting direction,
then cover side is separated.
2. Pick the pipe hole of the side cover. 1 3

CAUTION: After removing the pipe


hole, cut the burr for safety.
NOTICE When making pipe path through rear
wall, you donʼt need to pick the pipe hole.
Drain hose junction
1. Remove the rubber stopple in the desired drain direc-
tion.
2. Insert drain hose into the handle of drain pan, and
join drain hose and connecting hose according to the
figure as shown on the right.

28 _ Ceiling & Floor / Ceiling Suspended


10. Installation
10.5 Mounting the installation plate(Wall Mounting)
The wall you select should be strong and solid
Installation Plate
enough to prevent vibration
1. Mount the installation plate on the wall with
type "A" screws. While mounting the unit on a con-
crete wall, use anchor bolts.
• Mount the installation plate horizontally by aligning
the centerline using a level. Type "A" screw

2. Measure the wall and mark the centerline. It is also


important to use caution concerning the location of
the installation plate-routing of the wiring to power 70 70
Installation plate
outlets is through the walls typically. Drilling the

Indoor Units
hole through the wall for piping connections must
be done safely. Ø70mm 120 Ø70mm

more than 2000

Left rear piping Right rear piping

Floor

Ceiling & Floor / Ceiling Suspended _ 29


10. Installation
10.6 Mounting the anchor Nut & Bolt(Ceiling Mounting)
• Prepare 4 suspension bolts. (Each bolts length
should be same.) Anchor nut

• Measure and mark the position for the Suspension Ceiling

bolts and the piping hole. Nut Washer


235
Suspension
820
• Drill the hole for anchor nut on the ceiling. bolts

• Insert the nuts and washer onto the suspension bolts 40 Suspension bolt 50
for locking the suspension bolts on the ceiling.
100
• Mount the suspension bolts to the anchor-nuts firmly.
Reference
• Secure the hangers onto the Suspension bolts piping hole of piping
(Ø45) hole (Ø45)
(adjust level roughly.) using nuts, washers and
spring washers.
• Adjust a level with a level gauge on the direction of
left-right, back-forth by adjusting suspension bolts.
Indoor Units

Suspension
• Adjust a level on the direction of top-bottom by bolts

Spring
adjusting supension bolts. Then the unit will be washer
Hangen
Nut

inclined to the bottomside so as to drain well. Max.


12mm Washer
(Unit : mm)

Hanging bolt
: Tighten the nut and bolt to prevent unit falling. (W3/8 or M10)
Nut
Flat washer for M10
(W3/8 or M10)
(accessory)

Flat washer for M10


(accessory)
Nut
(W3/8 or M10)

30 _ Ceiling & Floor / Ceiling Suspended


10. Installation

: Installation Information For right piping. Follow the instruction below.

Good case Bad case


For left piping. Follow the instruction below. 1. Following bending type from right to
1. Press on the upper side of clamp. (Ⓐ) left could cause problem of pipe damage.

2. Unfold the tubing downward slowly. (Ⓑ)


3. Bend the tubing to the left side of chassis.

Indoor Units

Ceiling & Floor / Ceiling Suspended _ 31


10. Installation
10.7 Checking the Drainage
1. Set the air direction louvers up-and-down to the posi-
tion(horizontally) by hand.
To check the drainage.
1. Pour a glass of water on the evaporator using a ket-
tle.
2. Ensure the water flows through the drain hose of the
indoor unit without any leakage and goes out the
drain exit.
■ Checking the Drainage
1. Remove the Air Filter.
• To remove air filter, take hold of tab and pull slightly
upwards.
Indoor Units

2. Check the drainage.


• Spray one or two glasses of water upon the evapo-
rator.
• Ensure that water flows drain hose of indoor unit
without any leakage.

Drain piping Downward slope


1. The drain hose should point downward for easy drain
flow.
2. Do not make drain piping like the following.

Accumulated
Do not raise
drain water Less than
Air Tip of drain hose
50mm gap
dipped in water

Water Water Water


Waving leakage
leakage leakage Ditch

10.8 Panel Front Assembly


1. Suspend the hook of panel front in the groove.
2. Press the panel front. 1
3. Screw up panel front.
3
2

32 _ Ceiling & Floor / Ceiling Suspended


10. Installation
VJ/VK/VL Chassis
10.9 Select the best Location
Indoor unit
1. Do not have any heat or steam near the unit. More than
700mm
2. Select a place where there are no obstacles in
front of the unit.
3. Make sure that condensation drainage can be
conveniently routed away.
4. Do not install near a doorway.
5. Ensure that the interval between a wall and the More than
left (or right) of the unit is more than 700mm. 300mm
More than
6. Use a stud finder to locate studs to prevent

Indoor Units
unnecessary damage to the wall.
700mm

: In case that the unit is installed near the sea, the installation parts may be cor-
roded by salt. The installation parts (and the unit) should be treated with appropriate anti-corro-
sion measures.

Ceiling & Floor / Ceiling Suspended _ 33


10. Installation
10.10 Preparing Work for Installation
Open side cover
1. Remove two screws from side-cover as shown
in fig.
2. Unlock side-cover from side panel by slightly
pulling the edge of side cover. 2
Edge part
3. Tap the side-cover with your palm on the back-
side.(Inlet grill side.)
4. Hold the side-cover with other hand while tap- 1
ping to prevent it to fall down.
5. Remove the rubber stopple in the desired drain
direction.
6. Knock out the pipe hole from the left side-cover
Indoor Units

with the help or nipper/plier.


7. Knock hole on right side-cover only if right side
is selected for water drain.

34 _ Ceiling & Floor / Ceiling Suspended


10. Installation
MOUNTING THE ANCHOR NUT AND (Unit: mm)
BOLT DIM.
A B
MODEL
• Prepare 4 suspension bolts. (Each bolts length
VJ 855 320
should be same.)
VK 1255 320
• Measure and mark the position for the
Suspension bolts and the piping hole. VL 1655 320

• Drill the hole for anchor nut on the ceiling.


• Insert the nuts and washer onto the suspension Anchor nut
bolts for locking the suspension bolts on the ceil- A B
Ceiling
ing.
Suspension bolt
• Mount the suspension bolts to the anchor-nuts Nut Washer

Suspension
firmly. bolts

• Secure the hangers onto the Suspension bolts


(adjust level roughly.) using nuts, washers and
spring washers.

Indoor Units
• Adjust a level with a level gauge on the direction
of left-right, back-forth by adjusting suspension
bolts.
• Adjust a level on the direction of top-bottom by Suspension
adjusting supension bolts. Then the unit will be bolts

Spring
inclined to the bottomside so as to drain well. washer
Hangen
Nut

Max.
12mm Washer

Hanging bolt
: Tighten the nut and bolt to prevent unit falling. (W3/8 or M10)
Nut
Flat washer for M10
(W3/8 or M10)
(accessory)

Flat washer for M10


(accessory)
Nut
(W3/8 or M10)

DRILL A HOLE IN THE WALL. WALL


• Drill the piping hole with a ø70mm hole core drill. Indoor Outdoor
Drill the piping hole at either the right or the left
with the hole slightly slanted to the outdoor side.
(3/16"~5/16")
5-7mm

Ceiling & Floor / Ceiling Suspended _ 35


10. Installation
10.11 Indoor unit installation
Hang the Indoor unit on suspension bolt as per following guidelines:
1. Lift the indoor unit to sufficient height.
2. Insert the suspended part of four suspension bolt in the four hangers provided on the side of main body one by one.
3. Lower the indoor unit till the hangers rest on their respective flat washer.
4. Adjust the level in the top down direction by adjusting the suspension bolts.
Inclined the indoor unit as per direction provided in the fig

: Installation Information For Declination

1. Inclination of the indoor unit is very important for drain purposes in the convertible
type air conditioner.
2. Minimum thickness of the insulation for the connecting pipe shall be 10mm.
3. If the Installation Plates are fixed to horizontal line, the indoor unit after installing will be
Indoor Units

declined to the bottomside.

Front of view

• The unit must be horizontal or inclined at angle.


• The inclination should be less than or equal to 1° or in between 10 to 20mm inclined in drain direction as
shown in fig.
Ceiling

10~20mm

Side of view

• The unit must be inclined to the bottomside of the unit when finished installation.
Ceiling

10~20mm

36 _ Ceiling & Floor / Ceiling Suspended


10. Installation
10.12 Checking the Drainage
1. Set the air direction louvers up-and-down to the posi-
tion(horizontally) by hand.

To check the drainage.


1. Pour a glass of water on the evaporator using a ket-
tle.
2. Ensure the water flows through the drain hose of the
indoor unit without any leakage and goes out the
drain exit.

Indoor Units
Drain piping
Downward slope
1. The drain hose should point downward for easy drain
flow.

2. Do not make drain piping like the following.

Accumulated
Do not raise drain water
Tip of drain hose Less than
Air
dipped in water 50mm gap

Water Water Water


Waving
leakage leakage leakage Ditch

3. While merging numerous drain pipes, follow the procedure mentioned below.

Drain piping must have down-slope (1/50 to 1/100): be sure not to provide
up-and-down slope to prevent reversal flow.

Down-slope : 1/50~1/100

Ceiling & Floor / Ceiling Suspended _ 37


10. Installation
10.13 Wiring Connection
Connect the wires to the terminals on the control board individually according to the outdoor unit con-
nection.
• Ensure that the color of the wires of outdoor unit and the terminal No. are the same as those of
indoor unit respectively.

[Indoor Unit side] [Outdoor Unit side]

[Type 1]

Terminal Block Indoor SODU B SODU A IDU B IDU A INT B INT A


1(L) 2(N) 3 4

INDOOR POWER INPUT


[Type 2]
Indoor Units

Terminal Block Indoor SODU IDU INTERNET DRY1 DRY2 GND 12V
1(L) 2(N) 3 4 B A - - B A - - - -

INDOOR POWER INPUT

[Type 3]
Terminal block of outdoor unit
Terminal Block Indoor Central controller Indoor unit Outdoor unit
1(L) 2(N) 3 4 12V GND DRY2 DRY1 CEN CEN IDU IDU SODU SODU

INDOOR POWER INPUT

WARNING : Make sure that the screws of the terminal are free from looseness.

38 _ Ceiling & Floor / Ceiling Suspended


10. Installation
CAUTION:
After the confirmation of the above conditions, prepare the wiring as follows:

1) Never fail to have a separate power circuit specially for the air conditioner. As for the method of
wiring, follow the circuit diagram posted on the inside of control box cover.
2) Provide a circuit breaker switch between power source and the unit.
3) The screws which fasten the wiring in the casing of electrical fittings are liable to come loose
from vibrations to which the unit is subjected during the course of transportation. Check them
and make sure that they are all tightly fastened. (If they are loose, it could give rise to burn-out of
the wires.)
4) Specification of power source
5) Confirm that electrical capacity is sufficient.
6) Be sure that the starting voltage is maintained at more than 90 percent of the rated voltage
marked on the name plate.
7) Confirm that the cable thickness is as specified in the power sources specification. (Particularly

Indoor Units
note the relation between cable length and thickness.)
8) Never fail to equip a leakage breaker where it is wet or moist.
9) The following troubles would be caused by voltage drop-down.
• Vibration of a magnetic switch, damage on the contact point, fuse breaking, disturbance by the normal
function of an overload protection device.
• Proper starting power is not given to the compressor.

Ceiling & Floor / Ceiling Suspended _ 39


10. Installation

WIRED REMOTE CONTROLLER INSTALLATION


• Since the room temperature sensor is in the remote controller, the remote controller box should be installed in a place
away from direct sunlight, high humidity and direct supply of cold air to maintain proper space temperature.
Install the remote controller about 5ft(1.5m) above the floor in an area with good air circulation at an average tempera-
ture.
Do not install the remote controller where it can be affected by:
- Drafts, or dead spots behind doors and in corners.
- Hot or cold air from ducts.
- Radiant heat from sun or appliances.
- Concealed pipes and chimneys.
- Uncontrolled areas such as an outside wall behind the remote controller.
- This remote controller is equipped with a seven segment LED. display. For proper display of the remote controller
LED's, the remote controller should be installed properly as shown in Fig.1.
(The standard height is 1.2~1.5 m from floor level.)
Indoor Units

Remote Controller
TEMP
yes

no
TEMP

Remote Controller

no
TEMP
5feet
Remote
Controller

(1.5meters)
no

Fig.1 Typical locations for remote controller

40 _ Ceiling & Floor / Ceiling Suspended


11. Accessories
Standard Accessories(VE)

Type "A" screw and


Name Installation plate (Other)
plastic anchor

Quantity 1EA 4EA


• Owner's manual
• Installation manual

Shape

Indoor Units

CAUTION
• Use only those accessories (Standard or optional) which have designated specifications.

Ceiling & Floor / Ceiling Suspended _ 41


Indoor unit

Floor Standing
1. List of functions

2. Specifications

3. Dimensions

4. Piping Diagrams

5. Wiring Diagrams

6. Capacity Tables

7. Air Velocity and Temperature Distribution

8. Electric Characteristics

9. Sound Levels

10. Installation

11. Accessories
1. List of functions
ARNU07GCEA2, ARNU09GCEA2, ARNU12GCEA2
Category Function ARNU15GCEA2, ARNU18GCFA2, ARNU24GCFA2
ARNU07GCEU2, ARNU09GCEU2, ARNU12GCEU2
ARNU15GCEU2, ARNU18GCFU2, ARNU24GCFU2
Air supply outlet 1
Airflow direction control(left & right) -
Airflow direction control(up & down) -
Auto swing(left & right) -
Auto swing(up & down) -
Air flow
Airflow steps(fan/cool/heat) 3/3/3
Chaos swing -
Chaos wind(auto wind) -
Jet cool(Power wind) -
Swirl wind -
Deodorizing filter X
Air purifying Plasma air purifier X
Prefilter(washable / anti-fungus) O
Drain pump X

Indoor Units
E.S.P. control O
Installation
Electric heater(operation) X
High ceiling operation -
Hot start O
Reliability Self diagnosis O
Soft dry operation O
Auto changeover O(Heat recovery)
Auto cleaning X
Auto operation(artificial intelligence) O(Heat pump or Cooling only)
Auto restart operation O
Child lock O
Convenience Forced operation -
Group control O
Sleep mode X
Timer(on/off) O
Timer(weekly) O
Two thermistor control O
Wide wired remote controller PQRCVSL0/PQRCVSL0QW
Deluxe wired remote controller PQRCUDS0(B/S)
Individual Simple wired remote controller PQRCVCL0Q(W)
control Wired remote controller(for hotel use) PQRCHCA0Q(W)
Wireless LCD remote control PQWRH(C)Q0FDB
Zone control -
CTIE -
Special Electro thermostat -
function kit Remote temperature sensor -
Group control wire PZCWRCG3
Dry contact PQDSA(1)/PQDSB(1)/PQDSBC/PQDSBNGCM1/PQDSBCGCD0

O : Applied X : Not applied – : No relation


Option : Model name & price are different according to options, and assembled in factory with main unit.
Accessory : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate
package.

Floor Standing _ 1
2. Specification

Type Floor Standing


Model Unit ARNU07GCEA2 ARNU09GCEA2 ARNU12GCEA2
kW 2.2 2.8 3.6
Cooling Capacity kcal/h 1,900 2,400 3,100
Btu/h 7,500 9,600 12,300
kW 2.5 3.2 4.0
Heating Capacity kcal/h 2,200 2,800 3,400
Btu/h 8,500 10,900 13,600
Casing Galvanized Galvanized Galvanized
Steel Plate Steel Plate Steel Plate
mm 1,067 x 635 x 203 1,067 x 635 x 203 1,067 x 635 x 203
Dimensions(WxHxD) Body
inch 42 x 25 x 8 42 x 25 x 8 42 x 25 x 8
Coil Rows x Columns x FPI 2 x 12 x 19 2 x 12 x 19 2 x 12 x 19
Face Area m2 0.16 0.16 0.16
Type Sirocco Fan Sirocco Fan Sirocco Fan
Motor Output x Number W 28 28 28
Running Current A 0.15 0.15 0.15
Indoor Units

Fan Air Flow Rate(H / M / L) CMM 8.5 / 7.5 / 6.5 9.5 / 8.5 / 7.5 10.5 / 9.5 / 8.5
cfm 300 / 265 / 229 335 / 300 / 265 371 / 335 / 300
Drive Direct Direct Direct
Motor type BLDC BLDC BLDC
Temperature Control Microprocessor, Microprocessor, Microprocessor,
Thermostat for Thermostat for Thermostat for
cooling and heating cooling and heating cooling and heating
Sound Absorbing Thermal Insulation Material Foamed polystrene Foamed polystrene Foamed polystrene
Air Filter Resin Net(washable) Resin Net(washable) Resin Net(washable)
Safety Device Fuse Fuse Fuse
Liquid Side mm(inch) Ø6.35(1/4) Ø6.35(1/4) Ø6.35(1/4)
Pipe Connections Gas Side mm(inch) Ø12.7(1/2) Ø12.7(1/2) Ø12.7(1/2)
Drain Pipe(Internal Dia.) mm(inch) 12(15/32) 12(15/32) 12(15/32)
Net Weight kg(lbs) 27(59.5) 27(59.5) 27(59.5)
Noise Level(Sound Press, 1.5m, H / M / L) dB(A) 35 / 33 / 31 36 / 34 / 32 37 / 35 / 33
Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50
1, 220, 60 1, 220, 60 1, 220, 60
Refrigerant Control EEV EEV EEV
Power cable mm2 CV1.5 x 3C CV1.5 x 3C CV1.5 x 3C
Transmission cable mm2 CVV-SB 1.0~1.5 x 2C CVV-SB 1.0~1.5 x 2C CVV-SB 1.0~1.5 x 2C

Notes:-
1. Capacities are based on the following conditions: Conversion Formula
Cooling • Indoor temp. 27°C[80.6°F]DB/ 19°C[66.2°F]WB kcal/h= kW x 860
• Outdoor temp. 35°C[95°F]DB/ 24°C[75.2°F]WB Btu/h = kW x 3412
• Interconnecting Piping Length 7.5m cfm = m3/min x 35.3
• Level Difference of Zero l/s = CMM x 1000/60
Heating • Indoor temp. 20°C[68°F]DB/ 15°C[59°F]WB
• Outdoor temp. 7°C[44.6°F]DB/ 6°C[42.8°F]WB
• Interconnecting Piping Length 7.5m
• Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve
6. Anechoic chamber conversion value is measured at 1.5 m downward from unit centre.
The values depends on the ambient conditions and values are normally higher in actual operation.

2 _ Floor Standing
2. Specification

Type Floor Standing


Model Unit ARNU07GCEU2 ARNU09GCEU2 ARNU12GCEU2
kW 2.2 2.8 3.6
Cooling Capacity kcal/h 1,900 2,400 3,100
Btu/h 7,500 9,600 12,300
kW 2.5 3.2 4.0
Heating Capacity kcal/h 2,200 2,800 3,400
Btu/h 8,500 10,900 13,600
Casing Galvanized Galvanized Galvanized
Steel Plate Steel Plate Steel Plate
mm 978 x 639 x 190 978 x 639 x 190 978 x 639 x 190
Dimensions(WxHxD) Body
inch 38-1/2 x 25-5/32 x 7-15/32 38-1/2 x 25-5/32 x 7-15/32 38-1/2 x 25-5/32 x 7-15/32
Coil Rows x Columns x FPI 2 x 12 x 19 2 x 12 x 19 2 x 12 x 19
Face Area m2 0.16 0.16 0.16
Type Sirocco Fan Sirocco Fan Sirocco Fan
Motor Output x Number W 28 28 28
Running Current A 0.15 0.15 0.15

Indoor Units
Fan Air Flow Rate(H / M / L) CMM 8.5 / 7.5 / 6.5 9.5 / 8.5 / 7.5 10.5 / 9.5 / 8.5
cfm 300 / 265 / 229 335 / 300 / 265 371 / 335 / 300
Drive Direct Direct Direct
Motor type BLDC BLDC BLDC
Temperature Control Microprocessor, Microprocessor, Microprocessor,
Thermostat for Thermostat for Thermostat for
cooling and heating cooling and heating cooling and heating
Sound Absorbing Thermal Insulation Material Foamed polystrene Foamed polystrene Foamed polystrene
Air Filter Resin Net(washable) Resin Net(washable) Resin Net(washable)
Safety Device Fuse Fuse Fuse
Liquid Side mm(inch) Ø6.35(1/4) Ø6.35(1/4) Ø6.35(1/4)
Pipe Connections Gas Side mm(inch) Ø12.7(1/2) Ø12.7(1/2) Ø12.7(1/2)
Drain Pipe(Internal Dia.) mm(inch) 12(15/32) 12(15/32) 12(15/32)
Net Weight kg(lbs) 20(44.1) 20(44.1) 20(44.1)
Noise Level(Sound Press, 1.5m, H / M / L) dB(A) 35 / 33 / 31 36 / 34 / 32 37 / 35 / 33
Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50
1, 220, 60 1, 220, 60 1, 220, 60
Refrigerant Control EEV EEV EEV
Power cable mm2 CV1.5 x 3C CV1.5 x 3C CV1.5 x 3C
Transmission cable mm2 CVV-SB 1.0~1.5 x 2C CVV-SB 1.0~1.5 x 2C CVV-SB 1.0~1.5 x 2C

Notes:-
1. Capacities are based on the following conditions: Conversion Formula
Cooling • Indoor temp. 27°C[80.6°F]DB/ 19°C[66.2°F]WB kcal/h= kW x 860
• Outdoor temp. 35°C[95°F]DB/ 24°C[75.2°F]WB Btu/h = kW x 3412
• Interconnecting Piping Length 7.5m cfm = m3/min x 35.3
• Level Difference of Zero l/s = CMM x 1000/60
Heating • Indoor temp. 20°C[68°F]DB/ 15°C[59°F]WB
• Outdoor temp. 7°C[44.6°F]DB/ 6°C[42.8°F]WB
• Interconnecting Piping Length 7.5m
• Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve
6. Anechoic chamber conversion value is measured at 1.5 m downward from unit centre.
The values depends on the ambient conditions and values are normally higher in actual operation.

Floor Standing _ 3
2. Specification

Type Floor Standing


Model Unit ARNU15GCEA2 ARNU18GCFA2 ARNU24GCFA2
kW 4.5 5.6 7.1
Cooling Capacity kcal/h 3,900 4,800 6,100
Btu/h 15,400 19,100 24,200
kW 5.0 6.3 8.0
Heating Capacity kcal/h 4,300 5,400 6,900
Btu/h 17,100 21,500 27,300
Casing Galvanized Steel Plate Galvanized Steel Plate Galvanized Steel Plate
mm 1,067 x 635 x 203 1,345 x 635 x 203 1,345 x 635 x 203
Dimensions(WxHxD) Body
inch 42 x 25 x 8 52-15/16 x 25 x 8 52-15/16 x 25 x 8
Coil Rows x Columns x FPI 2 x 12 x 19 3 x 11 x 19 3 x 11 x 19
Face Area m2 0.16 0.23 0.23
Type Sirocco Fan Sirocco Fan Sirocco Fan
Motor Output x Number W 28 76 76
Running Current A 0.15 0.38 0.38
Fan Air Flow Rate(H / M / L) CMM 11.5 / 10.0 / 9.5 16.0 / 14.0 / 12.0 18.0 / 16.0 / 14.0
Indoor Units

cfm 406 / 353 / 335 565 / 494 / 424 635 / 565 / 494
Drive Direct Direct Direct
Motor type BLDC BLDC BLDC
Temperature Control Microprocessor, Thermostat Microprocessor, Thermostat Microprocessor, Thermostat
for cooling and heating for cooling and heating for cooling and heating
Sound Absorbing Thermal Insulation Material Foamed polystrene Foamed polystrene Foamed polystrene
Air Filter Resin Net(washable) Resin Net(washable) Resin Net(washable)
Safety Device Fuse Fuse Fuse
Liquid Side mm(inch) Ø6.35(1/4) Ø6.35(1/4) Ø9.52(3/8)
Pipe Connections Gas Side mm(inch) Ø12.7(1/2) Ø12.7(1/2) Ø15.88(5/8)
Drain Pipe(Internal Dia.) mm(inch) 12(15/32) 12(15/32) 12(15/32)
Net Weight kg(lbs) 27(59.5) 34(75.0) 34(75.0)
Noise Level(Sound Press, 1.5m, H / M / L) dB(A) 38 / 37 / 35 40 / 37 / 34 43 / 40 / 37
Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50
1, 220, 60 1, 220, 60 1, 220, 60
Refrigerant Control EEV EEV EEV
Power cable mm2 CV1.5 x 3C CV1.5 x 3C CV1.5 x 3C
Transmission cable mm2 CVV-SB 1.0~1.5 x 2C CVV-SB 1.0~1.5 x 2C CVV-SB 1.0~1.5 x 2C

Notes:-
1. Capacities are based on the following conditions: Conversion Formula
Cooling • Indoor temp. 27°C[80.6°F]DB/ 19°C[66.2°F]WB kcal/h= kW x 860
• Outdoor temp. 35°C[95°F]DB/ 24°C[75.2°F]WB Btu/h = kW x 3412
• Interconnecting Piping Length 7.5m cfm = m3/min x 35.3
• Level Difference of Zero l/s = CMM x 1000/60
Heating • Indoor temp. 20°C[68°F]DB/ 15°C[59°F]WB
• Outdoor temp. 7°C[44.6°F]DB/ 6°C[42.8°F]WB
• Interconnecting Piping Length 7.5m
• Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve
6. Anechoic chamber conversion value is measured at 1.5m downward from unit centre.
The values depends on the ambient conditions and values are normally higher in actual operation.

4 _ Floor Standing
2. Specification

Type Floor Standing


Model Unit ARNU15GCEU2 ARNU18GCFU2 ARNU24GCFU2
kW 4.5 5.6 7.1
Cooling Capacity kcal/h 3,900 4,800 6,100
Btu/h 15,400 19,100 24,200
kW 5.0 6.3 8.0
Heating Capacity kcal/h 4,300 5,400 6,900
Btu/h 17,100 21,500 27,300
Casing Galvanized Steel Plate Galvanized Steel Plate Galvanized Steel Plate
mm 978 x 639 x 190 1,256 x 639 x 190 1,256 x 639 x 190
Dimensions(WxHxD) Body
inch 38-1/2 x 25-5/32 x 7-15/32 49-7/16 x 25-5/32 x 7-15/32 49-7/16 x 25-5/32 x 7-15/32
Coil Rows x Columns x FPI 2 x 12 x 19 3 x 11 x 19 3 x 11 x 19
Face Area m2 0.16 0.23 0.23
Type Sirocco Fan Sirocco Fan Sirocco Fan
Motor Output x Number W 28 76 76
Running Current A 0.15 0.38 0.38
Fan Air Flow Rate(H / M / L) CMM 11.5 / 10.0 / 9.5 16.0 / 14.0 / 12.0 18.0 / 16.0 / 14.0

Indoor Units
cfm 406 / 353 / 335 565 / 494 / 424 635 / 565 / 494
Drive Direct Direct Direct
Motor type BLDC BLDC BLDC
Temperature Control Microprocessor, Thermostat Microprocessor, Thermostat Microprocessor, Thermostat
for cooling and heating for cooling and heating for cooling and heating
Sound Absorbing Thermal Insulation Material Foamed polystrene Foamed polystrene Foamed polystrene
Air Filter Resin Net(washable) Resin Net(washable) Resin Net(washable)
Safety Device Fuse Fuse Fuse
Liquid Side mm(inch) Ø6.35(1/4) Ø6.35(1/4) Ø9.52(3/8)
Pipe Connections Gas Side mm(inch) Ø12.7(1/2) Ø12.7(1/2) Ø15.88(5/8)
Drain Pipe(Internal Dia.) mm(inch) 12(15/32) 12(15/32) 12(15/32)
Net Weight kg(lbs) 20(44.1) 27(59.5) 27(59.5)
Noise Level(Sound Press, 1.5m, H / M / L) dB(A) 38 / 37 / 35 40 / 37 / 34 43 / 40 / 37
Power Supply Ø, V, Hz 1, 220-240, 50 1, 220-240, 50 1, 220-240, 50
1, 220, 60 1, 220, 60 1, 220, 60
Refrigerant Control EEV EEV EEV
Power cable mm2 CV1.5 x 3C CV1.5 x 3C CV1.5 x 3C
Transmission cable mm2 CVV-SB 1.0~1.5 x 2C CVV-SB 1.0~1.5 x 2C CVV-SB 1.0~1.5 x 2C

Notes:-
1. Capacities are based on the following conditions: Conversion Formula
Cooling • Indoor temp. 27°C[80.6°F]DB/ 19°C[66.2°F]WB kcal/h= kW x 860
• Outdoor temp. 35°C[95°F]DB/ 24°C[75.2°F]WB Btu/h = kW x 3412
• Interconnecting Piping Length 7.5m cfm = m3/min x 35.3
• Level Difference of Zero l/s = CMM x 1000/60
Heating • Indoor temp. 20°C[68°F]DB/ 15°C[59°F]WB
• Outdoor temp. 7°C[44.6°F]DB/ 6°C[42.8°F]WB
• Interconnecting Piping Length 7.5m
• Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve
6. Anechoic chamber conversion value is measured at 1.5m downward from unit centre.
The values depends on the ambient conditions and values are normally higher in actual operation.

Floor Standing _ 5
Indoor Units

1067 Floor Standing


ARNU07GCEA2 ARNU07GCEU2
1
ARNU09GCEA2 ARNU09GCEU2
ARNU12GCEA2 ARNU12GCEU2
1067 203

6 _ Floor Standing
ARNU15GCEA2 ARNU15GCEU2
3. Dimensions

(unit : mm)
Model W H D

635
ARNU07GCEA2
ARNU09GCEA2 1067 635 203
ARNU12GCEA2
ARNU15GCEA2
ARNU07GCEU2

70

49
ARNU09GCEU2 978 639 190
148.3 148.3
<With Case> 2 ARNU12GCEU2
ARNU15GCEU2

(unit : mm)
Number Name Descripition
1 Air discharge grill
978 190
2 Air suction grill
794 13 161 14

20.4
Note
1. Unit should be installed in compliance with the installation manual
in the product box.
2. Unit shall be grounded in accordance with the local regulations or

639
applicable national codes.

62.8
<Without Case>

76, Seongsan-dong, Changwon City, Gyeongnam,


641-713, Korea CHASSIS CODE: CE
Floor Standing

203
ARNU18GCFA2 ARNU18GCFU2
1
ARNU24GCFA2 ARNU24GCFU2
203
1345
3. Dimensions

(unit : mm)

635
Model W H D
ARNU18GCFA2
ARNU24GCFA2 1345 635 203

70

49.4
ARNU18GCFU2
148.3 1048.4 148.3 1256 639 190
ARNU24GCFU2
2
<With Case> (unit : mm)
Number Name Descripition
1 Air discharge grill
2 Air suction grill

1256 Note
1098 109.8 190
1072 30

21.4
161 14 1. Unit should be installed in compliance with the installation manual
in the product box.

81.4
2. Unit shall be grounded in accordance with the local regulations or
applicable national codes.

639
145

70
<Without Case>

76, Seongsan-dong, Changwon City, Gyeongnam,


641-713, Korea CHASSIS CODE: CF

Floor Standing _ 7
Indoor Units
4. Piping Diagrams

:Cooling
Heat Exchanger EEV :Heating
Filter
Th3 Th2
Sirroco Fan Filter

Th1 lndoor unit


Indoor Units

Refrigerant pipe connection port diameter


[Unit: mm(inch)]

Model Gas Liquid


ARNU07GCEA2
Ø12.7(1/2) Ø6.35(1/4)
ARNU07GCEU2
ARNU09GCEA2
Ø12.7(1/2) Ø6.35(1/4)
ARNU09GCEU2
ARNU12GCEA2
Ø12.7(1/2) Ø6.35(1/4)
ARNU12GCEU2
ARNU15GCEA2
Ø12.7(1/2) Ø6.35(1/4)
ARNU15GCEU2
ARNU18GCFA2
Ø12.7(1/2) Ø6.35(1/4)
ARNU18GCFU2
ARNU24GCFA2
Ø15.88(5/8) Ø9.52(3/8)
ARNU24GCFU2

LOC. Description
Th1 Room thermistor
Th2 Pipe in thermistor
Th3 Pipe out thermistor

8 _ Floor Standing
5. Wiring Diagrams
CE/CF Chassis

Indoor Units
CONNECTOR
NUMBER LOCATION POINT FUNCTION
CN-POWER AC power supply AC Power line input for indoor controller
CN-MOTOR1 Fan motor output Motor output of BLDC
CN-MOTOR2 Fan motor output Motor output of BLDC
CN-COMM Communication Communication between indoor and outdoor
CN-EEV Float switch input EEV Control output
CN-PIPE/IN Suction pipe sensor Pipe in thermistor
CN-PIPE/OUT Discharge pipe sensor Pipe out thermistor
CN-ROOM Room sensor Room thermistor
CN-REMO Remote controller Remote control line
CN-OPTION Option PCB Communication between main and option
CN-ZONE Zone controller Zone control line
CN-DISPLAY RF Remote controller RF Remote control line
CN-CC Dry contact Dry contact line

Dip Switch Setting Off On Remarks


SW3 GROUP Master Slave Group Control setting using Wired Remote Controller
Old Dry Contact Mode Setting
1. Variable : Auto/Manual Mode can be chosen by Wide wired
SW4 DRY CONTACT Variable Auto remote controller or Wireless remote controller
(When shipped from Factory → Manual Mode)
2. Auto : For Dry Contact, it is always Auto mode.
1. Duct model
-. OFF : Default(not operate continuosly )
-. ON : Fan operate continuosly
SW5 EXTRA 1 Off On 2. Cassette Model : No Function
3. Ceiling Suspended Model
-. OFF : Ceiling(default)
-. ON : Floor

CAUTION
For Multi V Model, Dip Switch 1,2,6,7,8 must be set OFF
That dip switch is used for the other model.

Floor Standing _ 9
6. Capacity Tables
6.1 Cooling Capacity Cooling capacity

Indoor air temp. (DB/WB, °C)


Capacity Outdoor 20 23 26 27 28 30 32
Index air temp. 14 16 18 19 20 22 24
(DB, °C) TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.9 1.7
12 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.9 1.6
14 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.8 1.6
16 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.8 1.6
18 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.7 1.6
20 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.7 1.6
21 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.7 1.5
23 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.6 1.5
2.2 25 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.6 1.7 2.6 1.5
27 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.5 1.6 2.6 1.5
29 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.5 1.6 2.5 1.5
Indoor Units

31 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.5 1.6 2.5 1.4
33 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.4 1.5 2.5 1.4
35 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.4 1.5 2.4 1.4
37 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.3 1.6 2.3 1.5 2.4 1.4
39 1.5 1.3 1.8 1.4 2.1 1.5 2.2 1.6 2.2 1.5 2.3 1.5 2.3 1.4
10 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.7 2.2
12 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.6 2.1
14 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.6 2.1
16 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.5 2.1
18 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.5 2.1
20 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.4 2.0
21 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.4 2.0
23 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.4 2.2 3.4 2.0
2.8 25 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.3 2.2 3.3 2.0
27 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.2 2.1 3.3 1.9
29 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.2 2.1 3.2 1.9
31 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.1 2.1 3.2 1.9
33 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.1 2.0 3.1 1.9
35 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 3.0 2.1 3.0 2.0 3.1 1.8
37 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 2.9 2.1 3.0 1.9 3.0 1.8
39 1.9 1.7 2.3 1.9 2.6 2.0 2.8 2.0 2.9 2.0 2.9 1.9 3.0 1.8
10 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.7 3.8 2.7 4.3 2.9 4.7 2.8
12 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.7 3.8 2.7 4.3 2.9 4.7 2.8
14 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.7 3.8 2.7 4.3 2.9 4.6 2.8
16 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.7 3.8 2.7 4.3 2.9 4.6 2.7
18 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.7 3.8 2.7 4.3 2.9 4.5 2.7
20 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.7 3.8 2.7 4.3 2.9 4.4 2.7
21 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.7 3.8 2.7 4.3 2.9 4.4 2.6
23 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.7 3.8 2.7 4.3 2.9 4.3 2.6
3.6 25 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.7 3.8 2.7 4.2 2.8 4.3 2.6
27 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.7 3.8 2.7 4.1 2.8 4.2 2.5
29 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.7 3.8 2.7 4.1 2.7 4.2 2.5
31 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.7 3.8 2.7 4.0 2.7 4.1 2.5
33 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.7 3.8 2.7 4.0 2.6 4.0 2.4
35 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.7 3.8 2.7 3.9 2.6 4.0 2.4
37 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.7 3.7 2.7 3.8 2.5 3.9 2.3
39 2.4 2.2 2.9 2.4 3.4 2.6 3.6 2.7 3.7 2.6 3.7 2.5 3.8 2.3

10 _ Floor Standing
6. Capacity Tables
Cooling capacity

Indoor air temp. (DB/WB, °C)


Capacity Outdoor 20 23 26 27 28 30 32
Index air temp. 14 16 18 19 20 22 24
(DB, °C) TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.6 5.9 3.5
12 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.6 5.8 3.5
14 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.6 5.8 3.4
16 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.6 5.7 3.4
18 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.6 5.6 3.4
20 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.6 5.5 3.3
21 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.6 5.5 3.3
23 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.4 3.6 5.4 3.2
4.5 25 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.3 3.5 5.3 3.2
27 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.2 3.4 5.3 3.2
29 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.1 3.4 5.2 3.1

Indoor Units
31 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 5.1 3.3 5.1 3.0
33 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 4.9 3.3 5.0 3.0
35 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.8 3.4 4.9 3.2 4.9 3.0
37 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.7 3.3 4.8 3.2 4.9 2.9
39 3.0 2.7 3.6 3.0 4.2 3.2 4.5 3.3 4.6 3.2 4.7 3.1 4.8 2.8
10 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.7 4.3 7.4 4.3
12 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.7 4.3 7.3 4.2
14 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.7 4.3 7.2 4.2
16 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.7 4.3 7.1 4.1
18 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.7 4.3 7.0 4.1
20 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.7 4.3 6.9 4.0
21 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.7 4.3 6.8 4.0
23 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.7 4.3 6.7 3.9
5.6 25 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.6 4.3 6.6 3.9
27 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.4 4.2 6.6 3.8
29 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.4 4.1 6.5 3.8
31 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.3 4.1 6.4 3.7
33 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.2 4.0 6.3 3.7
35 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 6.0 4.2 6.0 3.9 6.2 3.6
37 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 5.8 4.1 5.9 3.8 6.1 3.6
39 3.8 3.3 4.5 3.7 5.2 4.0 5.6 4.0 5.7 4.0 5.8 3.8 6.0 3.5
10 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.5 5.4 9.3 5.4
12 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.5 5.4 9.2 5.3
14 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.5 5.4 9.1 5.2
16 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.5 5.4 9.0 5.2
18 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.5 5.4 8.8 5.1
20 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.5 5.4 8.7 5.0
21 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.5 5.4 8.7 5.0
23 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.5 5.4 8.5 4.9
7.1 25 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.4 5.4 8.4 4.8
27 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.2 5.2 8.3 4.8
29 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.1 5.2 8.2 4.7
31 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 8.0 5.1 8.1 4.6
33 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 7.8 5.0 7.9 4.6
35 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.6 5.2 7.7 4.9 7.8 4.5
37 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.4 5.1 7.5 4.8 7.7 4.4
39 4.8 4.1 5.7 4.6 6.6 5.0 7.1 5.0 7.2 5.0 7.4 4.7 7.6 4.4
Notes:
TC: Total Capacity(kW), SHC: Sensible Heat Capacity(kW) 2. Refer to Capacity Correction Factor in the outdoor unit PDB for
1. Capacity tables show the representative value of conditions the actual performance data of each indoor unit and outdoor unit
which may occur. combination.

Floor Standing _ 11
6. Capacity Tables

6.2 Heating Capacity Heating capacity

Outdoor air Indoor air temp. (DB, °C)


Capacity temp. 16 18 20 21 22 24
Index TC TC TC TC TC TC
DB(°C) WB(°C)
kW kW kW kW kW kW
-24.8 -25.0 1.4 1.4 1.4 1.4 1.4 1.4
-21.8 -22.0 1.7 1.7 1.7 1.7 1.7 1.7
-19.8 -20.0 1.8 1.8 1.8 1.8 1.8 1.8
-18.8 -19.0 1.9 1.9 1.9 1.9 1.9 1.9
-16.7 -17.0 2.0 2.0 2.0 2.0 2.0 2.0
-14.7 -15.0 2.1 2.1 2.1 2.1 2.1 2.0
-12.6 -13.0 2.2 2.2 2.2 2.2 2.1 2.1
-10.5 -11.0 2.3 2.3 2.2 2.2 2.2 2.2
-9.5 -10.0 2.3 2.3 2.3 2.3 2.3 2.2
-8.5 -9.1 2.3 2.3 2.3 2.3 2.3 2.2
-7.0 -7.6 2.4 2.4 2.4 2.4 2.3 2.2
2.2 -5.0 -5.6 2.5 2.5 2.5 2.4 2.3 2.2
-3.0 -3.7 2.6 2.6 2.5 2.4 2.3 2.2
0.0 -0.7 2.7 2.6 2.5 2.4 2.3 2.2
3.0 2.2 2.7 2.7 2.5 2.4 2.3 2.2
Indoor Units

5.0 4.1 2.8 2.7 2.5 2.4 2.3 2.2


7.0 6.0 2.8 2.7 2.5 2.4 2.3 2.2
9.0 7.9 2.8 2.7 2.5 2.4 2.3 2.2
11.0 9.8 2.8 2.7 2.5 2.4 2.3 2.2
13.0 11.8 2.8 2.7 2.5 2.4 2.3 2.2
15.0 13.7 2.8 2.7 2.5 2.4 2.3 2.2
-24.8 -25.0 1.9 1.9 1.8 1.8 1.8 1.8
-21.8 -22.0 2.2 2.2 2.2 2.2 2.2 2.2
-19.8 -20.0 2.4 2.4 2.3 2.3 2.3 2.3
-18.8 -19.0 2.4 2.4 2.4 2.4 2.4 2.4
-16.7 -17.0 2.5 2.5 2.5 2.5 2.5 2.5
-14.7 -15.0 2.7 2.7 2.6 2.6 2.6 2.6
-12.6 -13.0 2.8 2.8 2.8 2.8 2.7 2.7
-10.5 -11.0 2.9 2.9 2.9 2.9 2.9 2.8
-9.5 -10.0 3.0 3.0 2.9 2.9 2.9 2.8
-8.5 -9.1 3.0 3.0 3.0 3.0 3.0 2.8
2.8 -7.0 -7.6 3.1 3.1 3.1 3.1 3.0 2.8
-5.0 -5.6 3.2 3.2 3.2 3.1 3.0 2.8
-3.0 -3.7 3.4 3.3 3.2 3.1 3.0 2.8
0.0 -0.7 3.4 3.3 3.2 3.1 3.0 2.8
3.0 2.2 3.5 3.4 3.2 3.1 3.0 2.8
5.0 4.1 3.6 3.4 3.2 3.1 3.0 2.8
7.0 6.0 3.6 3.4 3.2 3.1 3.0 2.8
9.0 7.9 3.6 3.4 3.2 3.1 3.0 2.8
11.0 9.8 3.6 3.4 3.2 3.1 3.0 2.8
13.0 11.8 3.6 3.4 3.2 3.1 3.0 2.8
15.0 13.7 3.6 3.4 3.2 3.1 3.0 2.8
-24.8 -25.0 2.3 2.3 2.3 2.3 2.3 2.3
-21.8 -22.0 2.8 2.8 2.8 2.8 2.8 2.8
-19.8 -20.0 2.9 2.9 2.9 2.9 2.9 2.9
-18.8 -19.0 3.0 3.0 3.0 3.0 3.0 3.0
-16.7 -17.0 3.1 3.1 3.1 3.1 3.1 3.1
-14.7 -15.0 3.3 3.3 3.3 3.3 3.3 3.3
-12.6 -13.0 3.5 3.4 3.4 3.4 3.4 3.4
-10.5 -11.0 3.6 3.6 3.6 3.6 3.6 3.5
-9.5 -10.0 3.7 3.7 3.7 3.7 3.7 3.5
-8.5 -9.1 3.8 3.8 3.7 3.7 3.7 3.5
-7.0 -7.6 3.9 3.9 3.9 3.8 3.7 3.5
3.6 -5.0 -5.6 4.0 4.0 4.0 3.9 3.7 3.5
-3.0 -3.7 4.2 4.1 4.0 3.9 3.7 3.5
0.0 -0.7 4.3 4.1 4.0 3.9 3.7 3.5
3.0 2.2 4.4 4.3 4.0 3.9 3.7 3.5
5.0 4.1 4.5 4.3 4.0 3.9 3.7 3.5
7.0 6.0 4.5 4.3 4.0 3.9 3.7 3.5
9.0 7.9 4.5 4.3 4.0 3.9 3.7 3.5
11.0 9.8 4.5 4.3 4.0 3.9 3.7 3.5
13.0 11.8 4.5 4.3 4.0 3.9 3.7 3.5
15.0 13.7 4.5 4.3 4.0 3.9 3.7 3.5

12 _ Floor Standing
6. Capacity Tables
Heating capacity

Outdoor air Indoor air temp. (DB, °C)


Capacity temp. 16 18 20 21 22 24
Index TC TC TC TC TC TC
DB(°C) WB(°C)
kW kW kW kW kW kW
-24.8 -25.0 2.9 2.9 2.9 2.9 2.9 2.9
-21.8 -22.0 3.5 3.5 3.5 3.5 3.5 3.5
-19.8 -20.0 3.7 3.7 3.7 3.7 3.7 3.6
-18.8 -19.0 3.8 3.7 3.7 3.7 3.7 3.7
-16.7 -17.0 3.9 3.9 3.9 3.9 3.9 3.9
-14.7 -15.0 4.1 4.1 4.1 4.1 4.1 4.1
-12.6 -13.0 4.3 4.3 4.3 4.3 4.3 4.3
-10.5 -11.0 4.5 4.5 4.5 4.5 4.5 4.4
-9.5 -10.0 4.6 4.6 4.6 4.6 4.6 4.4
-8.5 -9.1 4.7 4.7 4.7 4.7 4.7 4.4
4.5 -7.0 -7.6 4.8 4.8 4.8 4.8 4.7 4.4
-5.0 -5.6 5.0 5.0 5.0 4.8 4.7 4.4
-3.0 -3.7 5.3 5.1 5.0 4.8 4.7 4.4
0.0 -0.7 5.3 5.2 5.0 4.8 4.7 4.4
3.0 2.2 5.5 5.3 5.0 4.8 4.7 4.4
5.0 4.1 5.6 5.3 5.0 4.8 4.7 4.4

Indoor Units
7.0 6.0 5.6 5.3 5.0 4.8 4.7 4.4
9.0 7.9 5.6 5.3 5.0 4.8 4.7 4.4
11.0 9.8 5.6 5.3 5.0 4.8 4.7 4.4
13.0 11.8 5.6 5.3 5.0 4.8 4.7 4.4
15.0 13.7 5.6 5.3 5.0 4.8 4.7 4.4
-24.8 -25.0 3.6 3.6 3.6 3.6 3.6 3.6
-21.8 -22.0 4.4 4.4 4.4 4.4 4.4 4.4
-19.8 -20.0 4.6 4.6 4.6 4.6 4.6 4.6
-18.8 -19.0 4.8 4.7 4.7 4.7 4.7 4.7
-16.7 -17.0 5.0 5.0 5.0 4.9 4.9 4.9
-14.7 -15.0 5.2 5.2 5.2 5.2 5.2 5.2
-12.6 -13.0 5.5 5.4 5.4 5.4 5.4 5.4
-10.5 -11.0 5.7 5.7 5.7 5.7 5.7 5.5
-9.5 -10.0 5.8 5.8 5.8 5.8 5.8 5.5
-8.5 -9.1 5.9 5.9 5.9 5.9 5.9 5.5
5.6 -7.0
-5.0
-7.6
-5.6
6.1
6.3
6.1
6.3
6.1
6.3
6.0
6.1
5.9
5.9
5.5
5.5
-3.0 -3.7 6.6 6.5 6.3 6.1 5.9 5.5
0.0 -0.7 6.7 6.5 6.3 6.1 5.9 5.5
3.0 2.2 6.9 6.7 6.3 6.1 5.9 5.5
5.0 4.1 7.0 6.7 6.3 6.1 5.9 5.5
7.0 6.0 7.1 6.7 6.3 6.1 5.9 5.5
9.0 7.9 7.1 6.7 6.3 6.1 5.9 5.5
11.0 9.8 7.1 6.7 6.3 6.1 5.9 5.5
13.0 11.8 7.1 6.7 6.3 6.1 5.9 5.5
15.0 13.7 7.1 6.7 6.3 6.1 5.9 5.5
-24.8 -25.0 4.6 4.6 4.6 4.6 4.6 4.6
-21.8 -22.0 5.6 5.6 5.6 5.6 5.6 5.5
-19.8 -20.0 5.9 5.9 5.9 5.9 5.9 5.8
-18.8 -19.0 6.0 6.0 6.0 6.0 6.0 6.0
-16.7 -17.0 6.3 6.3 6.3 6.3 6.3 6.3
-14.7 -15.0 6.6 6.6 6.6 6.6 6.6 6.6
-12.6 -13.0 6.9 6.9 6.9 6.9 6.9 6.9
-10.5 -11.0 7.2 7.2 7.2 7.2 7.2 7.0
-9.5 -10.0 7.4 7.4 7.3 7.3 7.3 7.0
-8.5 -9.1 7.5 7.5 7.5 7.5 7.5 7.0
7.1 -7.0 -7.6 7.7 7.7 7.7 7.7 7.5 7.0
-5.0 -5.6 8.0 8.0 8.0 7.7 7.5 7.0
-3.0 -3.7 8.4 8.2 8.0 7.7 7.5 7.0
0.0 -0.7 8.6 8.3 8.0 7.7 7.5 7.0
3.0 2.2 8.8 8.5 8.0 7.7 7.5 7.0
5.0 4.1 8.9 8.5 8.0 7.7 7.5 7.0
7.0 6.0 9.0 8.5 8.0 7.7 7.5 7.0
9.0 7.9 9.0 8.5 8.0 7.7 7.5 7.0
11.0 9.8 9.0 8.5 8.0 7.7 7.5 7.0
13.0 11.8 9.0 8.5 8.0 7.7 7.5 7.0
15.0 13.7 9.0 8.5 8.0 7.7 7.5 7.0
Notes:
TC: Total Capacity(kW) 3. In accordance with operation limits of outdoor unit, applicable range of
1. Capacity tables show the representative value of conditions which may occur. capacity tables is different.
2. is shown as reference. When selecting the outdoor units, avoid the 4. Refer to Capacity Correction Factor in the outdoor unit PDB for the actual
outdoor air temperature range shown by . performance data of each indoor unit and outdoor unit combination.

Floor Standing _ 13
7. Air velocity and Temperature Distribution(Reference Data)
ARNU07GCEA2 /ARNU07GCEU2
Cooling Heating
Discharge angle:45° Discharge angle:60°

Air velocity [m/s] Air velocity [m/s]

2248
23 23 2.7m 24 26 24
3028 26 30 32 2.7m
21 22

34
22
21
32
20
21 23
2m

20
22

2m 30

36
38

26
19

19

34
36
22 18
1m 1m
18 28
21

1156
23

26
22 24 26 28
23 23 24 24
0 0
8m 7m 6m 5m 4m 3m 2m 1m 0 8m 7m 6m 5m 4m 3m 2m 1m 0

Temperature [°C] Temperature [°C]

0.5 2.7m 0.5 2.7m


Indoor Units

0.5
1

2m 2m
1.5

1
0.
5
1
0.5 1m

1.5
0.

1m
5

1
0 .2
2

5
3

0.5
2 141.5 0
0
8m 7m 6m 5m 4m 3m 2m 1m 0 8m 7m 6m 5m 4m 3m 2m 1m 0

ARNU09GCEA2 /ARNU09GCEU2
Cooling Heating
Discharge angle:45° Discharge angle:60°

Air velocity [m/s] Air velocity [m/s]


22
21 22
21
20 19 2.7m 2624 83 2624 83
80 2.7m

82
82
21
83
86
2m

84
2m
24
20
22

03
18
21
22 1

1m 26
84

17 1m
02 0
24
19 21
22

16
20

26
83

22 24 26
24
0 0
8m 7m 6m 5m 4m 3m 2m 1m 0 8m 7m 6m 5m 4m 3m 2m 1m 0

Temperature [°C] Temperature [°C]


0.5 1 2.7m 3.5 2.7m
3.5 1
0.5

2m 2m
1.5
0.5
1.
5

0.5
2

1 1m 1m
2.5

3.5

2
1.5

3.5 0 0
8m 7m 6m 5m 4m 3m 2m 1m 0 8m 7m 6m 5m 4m 3m 2m 1m 0

14 _ Floor Standing
7. Air velocity and Temperature Distribution(Reference Data)
ARNU12GCEA2 /ARNU12GCEU2
Cooling Heating
Discharge angle:45° Discharge angle:60°

Air velocity [m/s] Air velocity [m/s]


22 21 20 19 22 2.7m 24 2.7m

26
21 24 83 26 82 83

26
24

80
84

80
21 20

82
86
2m 2m

18
83
22

21
17 83

03
21 16
19

22 1
1m 1m

02
82
20 5

84
22 22
26 26
24 24
0 0
8m 7m 6m 5m 4m 3m 2m 1m 0 8m 7m 6m 5m 4m 3m 2m 1m 0

Temperature [°C] Temperature [°C]

Indoor Units
0.5 1
0.5 2.7m 3.5 2.7m

3.5
0.5
1. 2m
5 2m

1
2

1 .5
3
1

1.5 .5
1m 1m

1
0.

2.5
0.5 5
1.5
2.5

5
3.
1.5 0
0
8m 7m 6m 5m 4m 3m 2m 1m 0 8m 7m 6m 5m 4m 3m 2m 1m 0

ARNU15GCEA2 /ARNU15GCEU2
Cooling Heating
Discharge angle:45° Discharge angle:60°

Air velocity [m/s] Air velocity [m/s]

21 21 2.7m 32 2.7m
20 28 3230 3436
19
20

30

30

28
30
21
2m 38
2m
17
19

18
40

21
21 1

34

20
1m
8 15

16 1m
32

21 28
34

28
0 28
0
8m 7m 6m 5m 4m 3m 2m 1m 0 8m 7m 6m 5m 4m 3m 2m 1m 0

Temperature [°C] Temperature [°C]

1 0.5 2.7m 0.5 2.7m


0.5
1.0

0.5
0.5
0.5

1. 2m 2m
1

5
0.
5

1.0

1
1.
2

5
2 1m 1m
2.0

3.
2.

5
5

4
3

1.0
0.5

11.5
2 0 0
8m 7m 6m 5m 4m 3m 2m 1m 0 8m 7m 6m 5m 4m 3m 2m 1m 0

Floor Standing _ 15
7. Air velocity and Temperature Distribution(Reference Data)
ARNU18GCFA2 /ARNU18GCFU2
Cooling Heating
Discharge angle:45° Discharge angle:60°

Air velocity [m/s] Air velocity [m/s]

20
22 20 18 22 2.7m 30 32 30 34 2.7m

36
32 34
32

30
20 20 2m 2m

38
22

36
20

32
16

40
22

38 4 2
1m 1m

30
18
30

30
22 22
0 0
8m 7m 6m 5m 4m 3m 2m 1m 0 8m 7m 6m 5m 4m 3m 2m 1m 0

Temperature [°C] Temperature [°C]


Indoor Units

1.0 2.7m 0.5 1.0 0.5 2.7m


1.0
0.
5
2.0

2m 2m

2.
1.0

0.5
1.0
1m 1m

1.0
3.
0

2.
0 0
8m 7m 6m 5m 4m 3m 2m 1m 0 8m 7m 6m 5m 4m 3m 2m 1m 0

ARNU24GCFA2/ARNU24GCFU2
Cooling Heating
Discharge angle:45° Discharge angle:60°

Air velocity [m/s] Air velocity [m/s]

20 20 2.7m 30 32 34 30 38
32 2.7m

36
18

32 32
2m 2m
30

20
34
36

20 34
40

18
20

30

1m 1m
32
20

30 30
0 0
8m 7m 6m 5m 4m 3m 2m 1m 0 8m 7m 6m 5m 4m 3m 2m 1m 0

Temperature [°C] Temperature [°C]

1.0 2.7m 0.5 1.0 0.5 2.7m


1.0
0.5

2. 2m
0 2m
1.0
0.
5
1.

1.0
0

3.0
2.0
3.
0

1m 1m
1.0

2.
0
0.
2.
0
2.0

0 40 0
8m 7m 6m 5m 4m 3m 2m 1m 0 8m 7m 6m 5m 4m 3m 2m 1m 0

16 _ Floor Standing
8. Electric Characteristics
Units Power Supply IFM Input(W)
Model Type Hz Volts Voltage Range MCA MFA kW FLA Cooling Heating
ARNU07GCEA2 0.22 15 0.028 0.17 30 30
CE
ARNU07GCEU2 0.22 15 0.028 0.17 30 30
ARNU09GCEA2 0.22 15 0.028 0.17 30 30
CE
ARNU09GCEU2 0.22 15 0.028 0.17 30 30
ARNU12GCEA2 MAX.264 0.22 15 0.028 0.17 30 30
CE
ARNU12GCEU2 50 220-240 0.22 15 0.028 0.17 30 30
MIN.198
ARNU15GCEA2 0.22 15 0.028 0.17 30 30
CE
ARNU15GCEU2 0.22 15 0.028 0.17 30 30
ARNU18GCFA2 CF 0.55 15 0.076 0.44 80 80
ARNU18GCFU2 0.55 15 0.076 0.44 80 80
ARNU24GCFA2 0.55 15 0.076 0.44 80 80
CF
ARNU24GCFU2 0.55 15 0.076 0.44 80 80
ARNU07GCEA2 0.22 15 0.028 0.17 30 30

Indoor Units
CE
ARNU07GCEU2 0.22 15 0.028 0.17 30 30
ARNU09GCEA2 0.22 15 0.028 0.17 30 30
CE
ARNU09GCEU2 0.22 15 0.028 0.17 30 30
ARNU12GCEA2 0.22 15 0.028 0.17 30 30
CE MAX.242
ARNU12GCEU2 60 220 0.22 15 0.028 0.17 30 30
MIN.198 0.22 15 0.028 0.17 30 30
ARNU15GCEA2
CE
ARNU15GCEU2 0.22 15 0.028 0.17 30 30
ARNU18GCFA2 0.55 15 0.076 0.44 80 80
CF
ARNU18GCFU2 0.55 15 0.076 0.44 80 80
ARNU24GCFA2 0.55 15 0.076 0.44 80 80
CF
ARNU24GCFU2 0.55 15 0.076 0.44 80 80

Symbols:
MCA: Minimum Circuit Amperes (A)
MFA : Maximum Fuse Amperes(see note 5)
kW : Fan Motor Rated Output(kW)
FLA : Full Load Amperes(A)
IFM : Indoor Fan Motor

Note :
1. Voltage Range
Units are suitable for use on electrical system where voltage supplied to unit terminals is not below or above the
listed range limits.
2. Maximum allowable voltage unbalance between phase is 2%.
3. MCA/MFA
MCA = 1.25 x FLA
MFA ≤ 4 x FLA
( Next lower standard fuse rating. Minimum 15A)
4. Select wire size based on the MCA.
5. Instead of fuse, use Circuit Breaker.

Floor Standing _ 17
9. Sound Levels
Overall
Notes:
With Case Microphone 1. Sound measured at each 1.5m away from the front and bottom of the unit
2. Operating condition
- Power source : 220-240V 50Hz / 220V 60Hz E
- Cooling : Indoor temperature (27°C DB, 19°C WB),
1.5m Outdoor temperature (35°C DB, 24°C WB)
- Heating : Indoor temperature (20°C DB, 15°C WB),
Outdoor temperature (7°C DB, 6°C WB)
3. Reference accoustic pressure 0dB = 20μPa Du
4. Sound level will vary depending on a range of factors such as
1.5m (Fie
the construction(acoustic absorption coefficient) of particular
❈ Measuring place : Anechoic chamber room in which the equipment in installed.

Sound Levels dB(A)


Model
H M L
ARNU07GCEA2 ARNU07GCEU2 35 33 31
ARNU09GCEA2 ARNU09GCEU2 36 34 32
ARNU12GCEA2 ARNU12GCEU2 37 35 33
ARNU15GCEA2 ARNU15GCEU2 38 37 35
ARNU18GCFA2 ARNU18GCFU2 40 37 34
ARNU24GCFA2 ARNU24GCFU2 43 40 37
Indoor Units

Sound Pressure Level


ARNU07GCEA2 ARNU09GCEA2 ARNU12GCEA2
ARNU07GCEU2 ARNU09GCEU2 80
ARNU12GCEU2
80 80

70 70
70
Octave Band Sound Pressure Level (0dB = 20μPa)

Octave Band Sound Pressure Level (0dB = 20μPa)

Octave Band Sound Pressure Level (0dB = 20μPa)

NC-65 NC-65
NC-65 60
60 60
NC-60 NC-60
NC-60

NC-55 NC-55
50 NC-55 50
50
NC-50 NC-50
NC-50

NC-45 NC-45 NC-45


40 40 40

NC-40 NC-40 NC-40

NC-35 NC-35
30 30 NC-35 30

NC-30 NC-30 NC-30

20 NC-25 20 NC-25 20 NC-25

Approximate Approximate Approximate


NC-20 NC-20 NC-20
Hearing Hearing Hearing
Threshold Threshold Threshold NC-15
10 NC-15 NC-15 10
10
63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

ARNU15GCEA2 ARNU18GCFA2 ARNU24GCFA2


ARNU15GCEU2 ARNU18GCFU2 ARNU24GCFU2
80 80
80

70 70 70
Octave Band Sound Pressure Level (0dB = 20μPa)
Octave Band Sound Pressure Level (0dB = 20μPa)

Octave Band Sound Pressure Level (0dB = 20μPa)

NC-65 NC-65 NC-65


60 60 60

NC-60 NC-60 NC-60

NC-55 NC-55 NC-55


50 50 50

NC-50 NC-50 NC-50

NC-45 NC-45 NC-45


40 40 40

NC-40 NC-40 NC-40

30 NC-35 NC-35 30 NC-35


30
NC-30 NC-30 NC-30

20 NC-25 20 NC-25 20 NC-25


Approximate Approximate Approximate
NC-20 NC-20 NC-20
Hearing Hearing
Hearing
Threshold NC-15 Threshold
10 Threshold NC-15 10 NC-15
63 125 250 500 1000 2000 4000 8000 10
63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

18 _ Floor Standing
10. Installation
• Please read this instruction sheet completely before installing the product.
• When the power cord is damaged, replacement work shall be performed by authorized personnel only.
• Installation work must be performed in accordance with the national wiring standards by authorized personnel only.

10.1 Features

[CEA/CFA Type] Control panel

Air Outlet
Remote Controller

Control panel
TEMP

Remote Controller

Indoor Units
Air Filter

Air Inlet

[CEU/CFU Type]

Air Inlet

Air filter
(At Air Inlet)

Floor Standing _ 19
10. Installation
10.2 Selection of the best location
Indoor unit
Install the air conditioner in the location that satisfies the fol-
lowing conditions.
• The place shall easily bear a load exceeding four times the
indoor unitʼs weight.
• Sufficient space should be available to inspect the unit as in
the figure shown on the right. Window

• The place where the unit is installed shall be leveled.


• The place shall be suitable for easy connection of the indoor
unit with the outdoor unit.
• The place where the unit is installed should not be affected
by electrical noise.
• The place where air circulation in the room will be good .
Indoor Units

• There should not be any heat source or steam near the unit
Service space
Select an installation site where the following conditions are
20 or
more

satisfied and that meets your customer's approval.


Air flow
• Where the floor is strong enough to bear the indoor unit direction 175 or
weight. 100 or Front side 100 or more
more more 1500 or
• Where the floor is not significantly inclined. more
• Where nothing blocks the air passage. 1000 or Air inlet
more direction
• Where condensate can be properly drained.
• Where sufficient clearance for installation and maintenance Base
can be ensured.
• Where there is no possibility of flammable gas leakage.
• Where optimum air distribution can be ensured.
• Where piping between indoor and outdoor units is possible
within the allowable limit (Refer to the installation manual of
Window
the outdoor unit.)
• Keep the indoor and outdoor unit, power cable and transmis-
80 or more
654

sion wiring, at least 1m from TVs and radios, to prevent dis-


Ma
torted pictures and static.(Depending on the type and source inte
nan
of the electrical waves, static may be heard even when more ce
are
a
than 1 m away.)
Ao
(Unit: mm) rm
ore
Bo
Type A B rm
ore
[IMPORTANT]
CEU Type 788 1080
Leave sufficient clearance
CFU Type 1066 1358 for air inlet and maintenance.

20 _ Floor Standing
10. Installation

Bolt pitch
A
• Positioning of holes for fastening to the wall
(Unit:mm)

Type A

198
CEA, CEU 858
CFA, CFU 1136

270
1. Use the Installation mount for installation. Check
whether the wall is strong enough to bear the
weight of the unit or not. if there is a risk, reinforce
the wall before installing the unit.
2. The unit requires a minimum 100 mm clearance
below the unit for air intake. Also, ensure the unit is
leveled when installed so that drainage flows

Indoor Units
smoothly. If inclined, water can leak.
3. Depending upon the shape and nature of the wall
surface, operating sound may become bigger.

How to open/close front panel


(1)
• How to open/close the front panel
(2)
(1) Open the lid of control panel(Both left and right)
(2) Remove screws(Both left and right)
(2) (1)
(3) Lift the front panel of the unit (3)
• To close, perform the procedure in opposite
order.

Floor Standing _ 21
10. Installation
10.3 Drain piping work
• Drain piping must have downward slope(1/50 to 1/100): be sure not to provide up-and-down slope to prevent
reverse flow.
• During drain piping connection, be careful not to exert extra force on the drain port on the indoor unit.
• The outside diameter of the drain connection to the indoor unit is 21mm.

Piping material: Polyvinyl chloride pipe 25mm and


pipe fittings

• Be sure to install heat insulation on the drain piping

Heat insulation material: Polyethylene foam with


thickness more than 10 mm.

• If converging multiple drain pipes, install according to the procedure shown below.
Indoor Units

Slope downwards at a gradient


of at least 1/100
• After piping work is finished, check for drainage.
• Be sure to insulate all indoor units.

10.4 How to connect wirings


Remove the electric parts Box cover and connect the wiring

Fasten with clamp

Power Supply wiring Power supply wiring


ground wiring ground wiring
Fasten with (Field wiring) Transmission wiring
Transmission wiring
accessory clamp (Field wiring)

22 _ Floor Standing
10. Installation
10.5 Wiring Connection
Connect the wires to the terminals on the control board individually according to the outdoor unit connection.
• Ensure that the color of the wires of outdoor unit and the terminal No. are the same as those of indoor unit respectively.
[Indoor Unit side] [Outdoor Unit side]

[Type 1]

Terminal Block Indoor SODU B SODU A IDU B IDU A INT B INT A


1(L) 2(N) 3 4

INDOOR POWER INPUT


[Type 2]
Terminal Block Indoor SODU IDU INTERNET DRY1 DRY2 GND 12V
1(L) 2(N) 3 4 B A - - B A - - - -

Indoor Units
INDOOR POWER INPUT
[Type 3]
Terminal block of outdoor unit
Terminal Block Indoor Central controller Indoor unit Outdoor unit
1(L) 2(N) 3 4 12V GND DRY2 DRY1 CEN CEN IDU IDU SODU SODU

INDOOR POWER INPUT

WARNING : Make sure that the screws of the terminal are free from looseness.

CAUTION:

After the confirmation of the above conditions, prepare the wiring as follows:
1) Never fail to have a separate power circuit specifically for the air conditioner. As for the method of
wiring, follow the circuit diagram posted on the inside of control cover.
2) The screw which fasten the wiring in the casing of electrical fittings are liable to come loose from
vibrations to which the unit is subjected during the course of transportation. Check them and make
sure that they are all tightly fastened. (If they are loose, it could cause burn-out of the wires.)
3) Specification of power source.
4) Confirm that electrical capacity is sufficient.
5) See to that the starting voltage is maintained at more than 90 percent of the rated voltage marked on
the name plate.
6) Confirm that the cable thickness is as specified in the power source specification.
(Particularly note the relation between cable length and thickness.)
7) In a wet or moist area, always install an earth leakage circuit breaker.
8) The following would be caused by voltage drop.
• Vibration of a magnetic switch, which will damage the contact point, fuse breaking, disturbance of the nor-
mal function of the overload.
9) The means for disconnection from a power supply shall be incorporated in the fixed wiring and
have an air gap contact separation of at least 3mm in each active(phase) conductor.

Floor Standing _ 23
10. Installations

WIRED REMOTE CONTROLLER INSTALLATION


• Since the room temperature sensor is in the remote controller, the remote controller box should be installed in a place
away from direct sunlight, high humidity and direct supply of cold air to maintain proper space temperature.
Install the remote controller about 5ft(1.5m) above the floor in an area with good air circulation at an average tempera-
ture.
Do not install the remote controller where it can be affected by:
- Drafts, or dead spots behind doors and in corners.
- Hot or cold air from ducts.
- Radiant heat from sun or appliances.
- Concealed pipes and chimneys.
- Uncontrolled areas such as an outside wall behind the remote controller.
- This remote controller is equipped with a seven segment LED. display. For proper display of the remote controller
LED's, the remote controller should be installed properly as shown in Fig.1.
Indoor Units

(The standard height is 1.2~1.5 m from floor level.)

Remote Controller
TEMP
yes

no
TEMP

Remote Controller

no
TEMP
5feet
Remote
Controller

(1.5meters)
no

Fig.1 Typical locations for remote controller

24 _ Floor Standing
11. Accessories
Standard Accessories
Dran Level adjustment Insulation for Clamp
Name hose screw [Other]
fitting (Tie Wrap)

Quantity 1 EA 4 1 each. 8 pcs.


• Operation
(1) For gas pipe manual
• Installation
manual
Shape
(2) For liquid pipe

Indoor Units

CAUTION
• Use only those accessories (Standard or optional) which have designated specifications.

Floor Standing _ 25
Indoor unit

Console
1. List of functions

2. Specifications

3. Dimensions

4. Piping Diagrams

5. Wiring Diagrams

6. Capacity Tables

7. Air Velocity and Temperature Distribution

8. Electric Characteristics

9. Sound Levels

10. Installation

11. Accessories
1. List of functions

Category Function ARNU07GQAA2, ARNU09GQAA2, ARNU12GQAA2


ARNU15GQAA2

Air supply outlet 2


Airflow direction control(left & right) Manual
Airflow direction control(up & down) Auto
Auto swing(left & right) X
Auto swing(up & down) O
Air flow
Airflow steps(fan/cool/heat) 4/5/4
Chaos swing X
Chaos wind(auto wind) O
Jet cool(Power wind) O
Swirl wind X
Deodorizing filter X
Air purifying Ion Generator O
Prefilter(washable / anti-fungus) O
Drain pump X

Indoor Units
E.S.P. control X
Installation
Electric heater(operation) X
High ceiling operation X
Hot start O
Reliability Self diagnosis O
Soft dry operation O
Auto changeover O
Auto cleaning X
Auto operation(artificial intelligence) O
Auto restart operation O
Child lock O
Convenience Forced operation O
Group control O
Sleep mode O
Timer(on/off) O
Timer(weekly) O
Two thermistor control O
Wide wired remote controller PQRCVSL0/PQRCVSL0QW
Deluxe wired remote controller X
Individual
Simple wired remote controller PQRCVCL0Q(W)
control
Wired remote controller(for hotel use) PQRCHCA0Q(W)
Wireless LCD remote control PQWRH(C)Q0FDB
Zone control -
CTIE -
Special Electro thermostat -
function kit Remote temperature sensor -
Group control wire PZCWRCG3
Dry contact PQDSA(1)/PQDSB(1)/PQDSBC/PQDSBNGCM1/PQDSBCGCD0

O : Applied X : Not applied – : No relation


Option : Model name & price are different according to options, and assembled in factory with main unit.
Accessory : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate
package.

Console _ 1
2. Specification
Type Console
Model Unit ARNU07GQAA2 ARNU09GQAA2
Cooling Capacity kW 2.2 2.8
kcal/h 1,900 2,400
Btu/h 7,500 9,600
Heating Capacity kW 2.5 3.2
kcal/h 2,200 2,800
Btu/h 8,500 10,900
Casing Galvanized Steel Plate Galvanized Steel Plate
Dimensions Body mm 700 x 600 x 210 700 x 600 x 210
(W x H x D) inch 27-9/16 x 23-5/8 x 8-1/4 27-9/16 x 23-5/8 x 8-1/4
Coil Rows x Columns x FPI 19 x 2 x 19 19 x 2 x 19
Face Area m2 - -
Fan Type Turbo fan Turbo fan
Motor Output x Number W 48 x 1 48 x 1
Running Current A 0.3 0.3
Air Flow Rate(H/M/L) CMM 6.7 / 5.9 / 4.8 6.7 / 5.9 / 4.8
cfm 236 / 209 / 170 236 / 209 / 170
Indoor Units

Drive Direct Direct


Motor type BLDC BLDC
Temperature Control Microprocessor, Microprocessor,
Thermostat for Thermostat for
cooling and heating cooling and heating
Sound Absorbing Thermal Insulation Material Foamed polystrene Foamed polystrene
Safety Device Fuse Fuse
Pipe Liquid Side mm(inch) Ø6.35(1/4) Ø6.35(1/4)
Connections Gas Side mm(inch) Ø12.7(1/2) Ø12.7(1/2)
Drain(OD/ID) mm 17/12.2 17/12.2
Net Weight Body kg(lbs) 14.0(30.9) 14.0(30.9)
Noise Level(Sound Press, 1.5m, H/M/L) dB(A) 37 / 34 / 28 37 / 34 / 28
Power Supply Ø, V, Hz 1, 220 - 240, 50 1, 220 - 240, 50
Refrigerant Control EEV EEV
Power cable mm2(CV) 1.5 x 3C 1.5 x 3C
Transmission Cable mm2(VCTF-SB) 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C

Notes:-
1. Capacities are based on the following conditions: Conversion Formula
Cooling • Indoor temp. 27°C[80.6°F]DB/ 19°C[66.2°F]WB kcal/h= kW x 860
• Outdoor temp. 35°C[95°F]DB/ 24°C[75.2°F]WB Btu/h = kW x 3412
• Interconnecting Piping Length 7.5m cfm = m3/min x 35.3
• Level Difference of Zero l/s = CMM x 1000/60
Heating • Indoor temp. 20°C[68°F]DB/ 15°C[59°F]WB
• Outdoor temp. 7°C[44.6°F]DB/ 6°C[42.8°F]WB
• Interconnecting Piping Length 7.5m
• Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve
6. Anechoic chamber conversion value is measured at 1.5 m downward from unit centre.
The values depends on the ambient conditions and values are normally higher in actual operation.

2 _ Console
2. Specification
Type Console
Model Unit ARNU12GQAA2 ARNU15GQAA2
Cooling Capacity kW 3.6 4.5
kcal/h 3,100 3,900
Btu/h 12,300 15,400
Heating Capacity kW 4.0 5.0
kcal/h 3,400 4,300
Btu/h 13,600 17,100
Casing Galvanized Steel Plate Galvanized Steel Plate
Dimensions Body mm 700 x 600 x 210 700 x 600 x 210
(W x H x D) inch 27-9/16 x 23-5/8 x 8-1/4 27-9/16 x 23-5/8 x 8-1/4
Coil Rows x Columns x FPI 19 x 2 x 19 19 x 2 x 19
Face Area m2 - -
Fan Type Turbo fan Turbo fan
Motor Output x Number W 48 x 1 48 x 1
Running Current A 0.3 0.3
Air Flow Rate(H/M/L) CMM 7.5 / 5.9 / 4.8 8.7 / 6.7 / 5.9
cfm 265 / 209 / 170 307 / 236 / 209

Indoor Units
Drive Direct Direct
Motor type BLDC BLDC
Temperature Control Microprocessor, Microprocessor,
Thermostat for Thermostat for
cooling and heating cooling and heating
Sound Absorbing Thermal Insulation Material Foamed polystrene Foamed polystrene
Safety Device Fuse Fuse
Pipe Liquid Side mm(inch) Ø6.35(1/4) Ø6.35(1/4)
Connections Gas Side mm(inch) Ø12.7(1/2) Ø12.7(1/2)
Drain(OD/ID) mm 17/12.2 17/12.2
Net Weight Body kg(lbs) 14.0(30.9) 14.0(30.9)
Noise Level(Sound Press, 1.5m, H/M/L) dB(A) 39 / 34 / 28 42 / 37 / 31
Power Supply Ø, V, Hz 1, 220 - 240, 50 1, 220 - 240, 50
Refrigerant Control EEV EEV
Power cable mm2(CV) 1.5 x 3C 1.5 x 3C
Transmission Cable mm2(VCTF-SB) 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C
Notes:-
1. Capacities are based on the following conditions: Conversion Formula
Cooling • Indoor temp. 27°C[80.6°F]DB/ 19°C[66.2°F]WB kcal/h= kW x 860
• Outdoor temp. 35°C[95°F]DB/ 24°C[75.2°F]WB Btu/h = kW x 3412
• Interconnecting Piping Length 7.5m cfm = m3/min x 35.3
• Level Difference of Zero l/s = CMM x 1000/60
Heating • Indoor temp. 20°C[68°F]DB/ 15°C[59°F]WB
• Outdoor temp. 7°C[44.6°F]DB/ 6°C[42.8°F]WB
• Interconnecting Piping Length 7.5m
• Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. EEV : Electronic Expansion Valve
6. Anechoic chamber conversion value is measured at 1.5 m downward from unit centre.
The values depends on the ambient conditions and values are normally higher in actual operation.

Console _ 3
Indoor Units

Console

4 _ Console
ARNU07GQAA2
ARNU09GQAA2
666
ARNU12GQAA2
ARNU15GQAA2

45

95
3. Dimensions

210
4
No. Part Name Remark
1 Liquid pipe connection Ø6.35
700
2 Gas pipe connection Ø12.7
5 3 Drain pipe connection
4 Display & signal receiver
5 Air discharge grill
6 Air suction grill

600

584
6

125
6

90
80
18
639 1
82.5

160
140
150

120

80
37 68.5
100 3 37
2

CHASSIS CODE: QA
4. Piping Diagrams

:Cooling
Heat Exchanger EEV :Heating
Filter
Th3 Th2
Turbo Fan Filter

Th1 lndoor unit

Indoor Units
Refrigerant pipe connection port diameter

[Unit: mm(inch)]

Model Gas Liquid

ARNU07GQAA2 Ø12.7(1/2) Ø6.35(1/4)

ARNU09GQAA2 Ø12.7(1/2) Ø6.35(1/4)

ARNU12GQAA2 Ø12.7(1/2) Ø6.35(1/4)

ARNU15GQAA2 Ø12.7(1/2) Ø6.35(1/4)

LOC. Description
Th1 Room thermistor
Th2 Pipe in thermistor
Th3 Pipe out thermistor

Console _ 5
5. Wiring Diagrams
QA Chassis
Indoor Units

CONNECTOR NUMBER LOCATION POINT FUNCTION


CN-POWER AC Power supply AC Power line input for indoor controller
CN-MOTOR1 Fan motor output Motor output of BLDC
CN-D/PUMP Drain pump output AC output for drain pump
CN-485 Communication Connection between indoor and outdoor
CN-DISP Display Display of indoor status
CN-EEV EEV Output EEV Control output
CN-VANE2 Step motor Step motor output
CN-FLOAT Float switch input Float switch sensing
CN-PIPE/IN Suction pipe sensor Pipe in thermistor
CN-PIPE/OUT Discharge pipe sensor Pipe out thermistor
CN-ROOM Room sensor Room air thermistor
CN-REMO Remote controller Remote control line
CN-CC Dry contact Dry contact line
CN-AIRC Air clean Air cleaner control

Dip Switch Setting Off On Remarks


SW3 GROUP Master Slave Group Control setting using Wired Remote Controller
Old Dry Contact Mode Setting
1. Variable : Auto/Manual Mode can be chosen by Wide wired
SW4 DRY CONTACT Variable Auto remote controller or Wireless remote controller
(When shipped from Factory → Manual Mode)
2. Auto : For Dry Contact, it is always Auto mode.
1. Duct model
-. OFF : Default(not operate continuosly )
-. ON : Fan operate continuosly
SW5 EXTRA 1 Off On 2. Cassette Model : No Function
3. Ceiling Suspended Model
-. OFF : Ceiling(default)
-. ON : Floor

CAUTION
For Multi V Model, Dip Switch 1,2,6,7,8 must be set OFF
That dip switch is used for the other model.

6 _ Console
6. Capacity Tables
6.1 Cooling Capacity Cooling capacity

Indoor air temp. (DB/WB, °C)


Capacity Outdoor 20 23 26 27 28 30 32
Index air temp. 14 16 18 19 20 22 24
(DB, °C) TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10 1.5 1.3 1.8 1.4 2.1 1.6 2.2 1.6 2.3 1.6 2.6 1.5 2.8 1.6
12 1.5 1.3 1.8 1.4 2.1 1.6 2.2 1.6 2.3 1.6 2.6 1.5 2.8 1.6
14 1.5 1.3 1.8 1.4 2.1 1.6 2.2 1.6 2.3 1.6 2.6 1.5 2.8 1.6
16 1.5 1.3 1.8 1.4 2.1 1.6 2.2 1.6 2.3 1.6 2.6 1.5 2.7 1.6
18 1.5 1.3 1.8 1.4 2.1 1.6 2.2 1.6 2.3 1.6 2.6 1.5 2.7 1.6
20 1.5 1.3 1.8 1.4 2.1 1.6 2.2 1.6 2.3 1.6 2.6 1.5 2.7 1.6
21 1.5 1.3 1.8 1.4 2.1 1.6 2.2 1.6 2.3 1.6 2.6 1.5 2.7 1.6
23 1.5 1.3 1.8 1.4 2.1 1.6 2.2 1.6 2.3 1.6 2.5 1.5 2.6 1.5

Indoor Units
25 1.5 1.3 1.8 1.4 2.1 1.6 2.2 1.6 2.3 1.6 2.5 1.5 2.6 1.5
2.2 27 1.5 1.3 1.8 1.4 2.1 1.6 2.2 1.6 2.3 1.6 2.5 1.5 2.6 1.5
29 1.5 1.3 1.8 1.4 2.1 1.6 2.2 1.6 2.3 1.6 2.5 1.4 2.5 1.5
31 1.5 1.3 1.8 1.4 2.1 1.6 2.2 1.6 2.3 1.6 2.4 1.4 2.5 1.4
33 1.5 1.3 1.8 1.4 2.1 1.6 2.2 1.6 2.3 1.6 2.4 1.4 2.4 1.4
35 1.5 1.3 1.8 1.4 2.1 1.6 2.2 1.6 2.3 1.6 2.4 1.4 2.4 1.4
37 1.5 1.3 1.8 1.4 2.1 1.6 2.2 1.6 2.2 1.6 2.3 1.4 2.4 1.4
39 1.5 1.3 1.8 1.4 2.1 1.6 2.1 1.5 2.2 1.5 2.3 1.3 2.3 1.4
42 1.5 1.3 1.8 1.4 2.1 1.6 2.1 1.5 2.2 1.5 2.2 1.3 2.3 1.3
44 1.5 1.3 1.8 1.4 2.0 1.5 2.1 1.5 2.1 1.5 2.2 1.3 2.2 1.3
46 1.5 1.3 1.8 1.4 1.9 1.5 2.0 1.4 2.0 1.4 2.0 1.2 2.0 1.2
10 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.3 1.9 3.6 2.1
12 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.3 1.9 3.6 2.0
14 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.3 1.9 3.5 2.0
16 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.3 1.9 3.5 2.0
18 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.3 1.9 3.5 2.0
20 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.3 1.9 3.4 2.0
21 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.3 1.9 3.4 2.0
23 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.2 1.9 3.3 1.9
25 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.2 1.8 3.3 1.9
2.8 27 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.2 1.8 3.3 1.9
29 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 3.0 2.0 3.1 1.8 3.2 1.8
31 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 2.9 2.0 3.1 1.8 3.2 1.8
33 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 2.9 2.0 3.0 1.8 3.1 1.8
35 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 2.9 2.0 3.0 1.7 3.1 1.8
37 1.9 1.6 2.3 1.8 2.6 2.0 2.8 2.0 2.8 2.0 2.9 1.7 3.0 1.7
39 1.9 1.6 2.3 1.8 2.6 2.0 2.7 1.9 2.8 1.9 2.9 1.7 3.0 1.7
42 1.9 1.6 2.3 1.8 2.6 2.0 2.7 1.9 2.8 1.9 2.8 1.6 2.9 1.7
44 1.9 1.6 2.3 1.8 2.6 1.9 2.7 1.9 2.7 1.9 2.8 1.6 2.9 1.6
46 1.9 1.6 2.3 1.8 2.5 1.8 2.5 1.8 2.5 1.7 2.6 1.5 2.6 1.5

Console _ 7
6. Capacity Tables
Cooling capacity

Indoor air temp. (DB/WB, °C)


Capacity Outdoor 20 23 26 27 28 30 32
Index air temp. 14 16 18 19 20 22 24
(DB, °C) TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
kW kW kW kW kW kW kW kW kW kW kW kW kW kW
10 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.5 4.6 2.7
12 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.5 4.6 2.7
14 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.5 4.5 2.6
16 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.5 4.5 2.6
18 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.3 2.5 4.4 2.6
20 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.2 2.5 4.4 2.6
21 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.2 2.4 4.4 2.5
23 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.1 2.4 4.3 2.5
Indoor Units

25 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.1 2.4 4.2 2.5
3.6 27 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.1 2.4 4.2 2.4
29 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.7 4.0 2.3 4.1 2.4
31 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.8 2.6 4.0 2.3 4.1 2.4
33 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.7 2.6 3.9 2.3 4.0 2.3
35 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.7 2.6 3.9 2.2 3.9 2.3
37 2.4 2.1 2.9 2.4 3.4 2.6 3.6 2.6 3.7 2.5 3.8 2.2 3.9 2.3
39 2.4 2.1 2.9 2.4 3.4 2.6 3.5 2.5 3.6 2.5 3.7 2.2 3.8 2.2
42 2.4 2.1 2.9 2.4 3.4 2.5 3.5 2.5 3.5 2.5 3.6 2.1 3.7 2.2
44 2.4 2.1 2.9 2.4 3.3 2.5 3.4 2.5 3.5 2.4 3.6 2.1 3.7 2.1
46 2.4 2.1 2.9 2.4 3.2 2.4 3.2 2.3 3.3 2.3 3.3 1.9 3.3 1.9
10 3.0 2.7 3.6 2.9 4.2 3.2 4.5 3.2 4.8 3.3 5.4 3.1 5.8 3.4
12 3.0 2.7 3.6 2.9 4.2 3.2 4.5 3.2 4.8 3.3 5.4 3.1 5.7 3.3
14 3.0 2.7 3.6 2.9 4.2 3.2 4.5 3.2 4.8 3.3 5.4 3.1 5.7 3.3
16 3.0 2.7 3.6 2.9 4.2 3.2 4.5 3.2 4.8 3.3 5.4 3.1 5.6 3.3
18 3.0 2.7 3.6 2.9 4.2 3.2 4.5 3.2 4.8 3.3 5.3 3.1 5.6 3.2
20 3.0 2.7 3.6 2.9 4.2 3.2 4.5 3.2 4.8 3.3 5.3 3.1 5.5 3.2
21 3.0 2.7 3.6 2.9 4.2 3.2 4.5 3.2 4.8 3.3 5.2 3.1 5.5 3.2
23 3.0 2.7 3.6 2.9 4.2 3.2 4.5 3.2 4.8 3.3 5.2 3.0 5.4 3.1
25 3.0 2.7 3.6 2.9 4.2 3.2 4.5 3.2 4.8 3.3 5.1 3.0 5.3 3.1
4.5 27 3.0 2.7 3.6 2.9 4.2 3.2 4.5 3.2 4.8 3.3 5.1 3.0 5.2 3.1
29 3.0 2.7 3.6 2.9 4.2 3.2 4.5 3.2 4.8 3.3 5.0 2.9 5.2 3.0
31 3.0 2.7 3.6 2.9 4.2 3.2 4.5 3.2 4.7 3.3 5.0 2.9 5.1 3.0
33 3.0 2.7 3.6 2.9 4.2 3.2 4.5 3.2 4.7 3.3 4.9 2.9 5.0 2.9
35 3.0 2.7 3.6 2.9 4.2 3.2 4.5 3.2 4.6 3.2 4.8 2.8 4.9 2.9
37 3.0 2.7 3.6 2.9 4.2 3.2 4.4 3.2 4.6 3.2 4.7 2.8 4.8 2.8
39 3.0 2.7 3.6 2.9 4.2 3.2 4.4 3.2 4.5 3.1 4.7 2.7 4.8 2.8
42 3.0 2.7 3.6 2.9 4.2 3.2 4.3 3.1 4.4 3.1 4.5 2.7 4.7 2.7
44 3.0 2.7 3.6 2.9 4.1 3.1 4.3 3.1 4.4 3.0 4.5 2.6 4.6 2.7
46 3.0 2.7 3.6 2.9 4.0 3.0 4.0 2.9 4.1 2.8 4.1 2.4 4.2 2.4
Notes:
TC: Total Capacity(kW), SHC: Sensible Heat Capacity(kW) 2. Refer to Capacity Correction Factor in the outdoor unit PDB for
1. Capacity tables show the representative value of conditions the actual performance data of each indoor unit and outdoor unit
which may occur. combination.

8 _ Console
6. Capacity Tables
6.2 Heating Capacity Heating capacity

Outdoor air Indoor air temp. (DB, °C)


Capacity temp. 16 18 20 21 22 24
Index TC TC TC TC TC TC
DB(°C) WB(°C)
kW kW kW kW kW kW
-24.8 -25.0 1.4 1.4 1.4 1.4 1.4 1.4
-21.8 -22.0 1.7 1.7 1.7 1.7 1.7 1.7
-19.8 -20.0 1.8 1.8 1.8 1.8 1.8 1.8
-18.8 -19.0 1.9 1.9 1.9 1.9 1.9 1.9
-16.7 -17.0 2.0 2.0 2.0 2.0 2.0 2.0
-14.7 -15.0 2.1 2.1 2.1 2.1 2.1 2.0
-12.6 -13.0 2.2 2.2 2.2 2.2 2.1 2.1
-10.5 -11.0 2.3 2.3 2.2 2.2 2.2 2.2
-9.5 -10.0 2.3 2.3 2.3 2.3 2.3 2.2
-8.5 -9.1 2.3 2.3 2.3 2.3 2.3 2.2
2.2 -7.0 -7.6 2.4 2.4 2.4 2.4 2.3 2.2
-5.0 -5.6 2.5 2.5 2.5 2.4 2.3 2.2
-3.0 -3.7 2.6 2.6 2.5 2.4 2.3 2.2
0.0 -0.7 2.7 2.6 2.5 2.4 2.3 2.2

Indoor Units
3.0 2.2 2.7 2.7 2.5 2.4 2.3 2.2
5.0 4.1 2.8 2.7 2.5 2.4 2.3 2.2
7.0 6.0 2.8 2.7 2.5 2.4 2.3 2.2
9.0 7.9 2.8 2.7 2.5 2.4 2.3 2.2
11.0 9.8 2.8 2.7 2.5 2.4 2.3 2.2
13.0 11.8 2.8 2.7 2.5 2.4 2.3 2.2
15.0 13.7 2.8 2.7 2.5 2.4 2.3 2.2
-24.8 -25.0 1.9 1.9 1.8 1.8 1.8 1.8
-21.8 -22.0 2.2 2.2 2.2 2.2 2.2 2.2
-19.8 -20.0 2.4 2.4 2.3 2.3 2.3 2.3
-18.8 -19.0 2.4 2.4 2.4 2.4 2.4 2.4
-16.7 -17.0 2.5 2.5 2.5 2.5 2.5 2.5
-14.7 -15.0 2.7 2.7 2.6 2.6 2.6 2.6
-12.6 -13.0 2.8 2.8 2.8 2.8 2.7 2.7
-10.5 -11.0 2.9 2.9 2.9 2.9 2.9 2.8
2.8 -9.5 -10.0 3.0 3.0 2.9 2.9 2.9 2.8
-8.5 -9.1 3.0 3.0 3.0 3.0 3.0 2.8
-7.0 -7.6 3.1 3.1 3.1 3.1 3.0 2.8
-5.0 -5.6 3.2 3.2 3.2 3.1 3.0 2.8
-3.0 -3.7 3.4 3.3 3.2 3.1 3.0 2.8
0.0 -0.7 3.4 3.3 3.2 3.1 3.0 2.8
3.0 2.2 3.5 3.4 3.2 3.1 3.0 2.8
5.0 4.1 3.6 3.4 3.2 3.1 3.0 2.8
7.0 6.0 3.6 3.4 3.2 3.1 3.0 2.8
9.0 7.9 3.6 3.4 3.2 3.1 3.0 2.8
11.0 9.8 3.6 3.4 3.2 3.1 3.0 2.8
13.0 11.8 3.6 3.4 3.2 3.1 3.0 2.8
15.0 13.7 3.6 3.4 3.2 3.1 3.0 2.8
-24.8 -25.0 2.3 2.3 2.3 2.3 2.3 2.3
-21.8 -22.0 2.8 2.8 2.8 2.8 2.8 2.8
-19.8 -20.0 2.9 2.9 2.9 2.9 2.9 2.9
-18.8 -19.0 3.0 3.0 3.0 3.0 3.0 3.0
-16.7 -17.0 3.1 3.1 3.1 3.1 3.1 3.1
-14.7 -15.0 3.3 3.3 3.3 3.3 3.3 3.3
-12.6 -13.0 3.5 3.4 3.4 3.4 3.4 3.4
-10.5 -11.0 3.6 3.6 3.6 3.6 3.6 3.5
3.6 -9.5 -10.0 3.7 3.7 3.7 3.7 3.7 3.5
-8.5 -9.1 3.8 3.8 3.7 3.7 3.7 3.5
-7.0 -7.6 3.9 3.9 3.9 3.8 3.7 3.5
-5.0 -5.6 4.0 4.0 4.0 3.9 3.7 3.5
-3.0 -3.7 4.2 4.1 4.0 3.9 3.7 3.5
0.0 -0.7 4.3 4.1 4.0 3.9 3.7 3.5
3.0 2.2 4.4 4.3 4.0 3.9 3.7 3.5
5.0 4.1 4.5 4.3 4.0 3.9 3.7 3.5
7.0 6.0 4.5 4.3 4.0 3.9 3.7 3.5
9.0 7.9 4.5 4.3 4.0 3.9 3.7 3.5
11.0 9.8 4.5 4.3 4.0 3.9 3.7 3.5
13.0 11.8 4.5 4.3 4.0 3.9 3.7 3.5
15.0 13.7 4.5 4.3 4.0 3.9 3.7 3.5

Console _ 9
6. Capacity Tables
Heating capacity

Outdoor air Indoor air temp. (DB, °C)


Capacity temp. 16 18 20 21 22 24
Index TC TC TC TC TC TC
DB(°C) WB(°C)
kW kW kW kW kW kW
-24.8 -25.0 2.9 2.9 2.9 2.9 2.9 2.9
-21.8 -22.0 3.5 3.5 3.5 3.5 3.5 3.5
-19.8 -20.0 3.7 3.7 3.7 3.7 3.7 3.6
-18.8 -19.0 3.8 3.7 3.7 3.7 3.7 3.7
-16.7 -17.0 3.9 3.9 3.9 3.9 3.9 3.9
-14.7 -15.0 4.1 4.1 4.1 4.1 4.1 4.1
-12.6 -13.0 4.3 4.3 4.3 4.3 4.3 4.3
-10.5 -11.0 4.5 4.5 4.5 4.5 4.5 4.4
-9.5 -10.0 4.6 4.6 4.6 4.6 4.6 4.4
-8.5 -9.1 4.7 4.7 4.7 4.7 4.7 4.4
4.5 -7.0 -7.6 4.8 4.8 4.8 4.8 4.7 4.4
-5.0 -5.6 5.0 5.0 5.0 4.8 4.7 4.4
-3.0 -3.7 5.3 5.1 5.0 4.8 4.7 4.4
0.0 -0.7 5.3 5.2 5.0 4.8 4.7 4.4
Indoor Units

3.0 2.2 5.5 5.3 5.0 4.8 4.7 4.4


5.0 4.1 5.6 5.3 5.0 4.8 4.7 4.4
7.0 6.0 5.6 5.3 5.0 4.8 4.7 4.4
9.0 7.9 5.6 5.3 5.0 4.8 4.7 4.4
11.0 9.8 5.6 5.3 5.0 4.8 4.7 4.4
13.0 11.8 5.6 5.3 5.0 4.8 4.7 4.4
15.0 13.7 5.6 5.3 5.0 4.8 4.7 4.4

Notes:
TC: Total Capacity(kW) 3. In accordance with operation limits of outdoor unit, applicable range of
1. Capacity tables show the representative value of conditions which may occur. capacity tables is different.
2. is shown as reference. When selecting the outdoor units, avoid the 4. Refer to Capacity Correction Factor in the outdoor unit PDB for the actual
outdoor air temperature range shown by . performance data of each indoor unit and outdoor unit combination.

10 _ Console
7. Air Velocity and Temperature Distribution(Reference Data)
ARNU07GQAA2
Cooling Heating
Discharge angle:40° Discharge angle:50°

Air velocity [m/s] 2.7m


Air velocity [m/s]
0.2 2.7m
0.1 1.0

0.4

0.2
2 0.5
0.3

0.4 0. 0.5
0.3
0.2

1.0
2m

0.1
0.1
2m
0.1

0.2

1.0
0.4

0.3
0. 0.5
3
0.3

0.2
1.5 0.2 1.0

0.2
0.4
1m 1m

0.1
0.1

1.0
0.2
0.
0.2

0.5
0.1

3
0.1 0.2
0.3 0.2
0.1 0.2 0.2
0.3 0.2 0.2
0.4 0.3 0.5 0.2
0.2
1.5
0 2.0
0
5m 4m 3m 2m 1m 0 5m 4m 3m 2m 1m 0

Temperature [°C] Temperature [°C]


2.7m 36.7
2.7m
36.6
13.4

36.7
.7
13.4

36

Indoor Units
13.4
13.8

2m 2m
36.7
13.4

36.6
13.8 36.7

13.8 36.6 .6 36.6


36
12.2 36.6
36.6
1m 1m

39.0 6.6 36.6


36.7
.8 13.9
13
11.5

13.9 13.8

39.0
13.8

3
13 .7 36
.4 36 .6
13
.8

13 13.4 36
13.4 36.7
.8
.6
11.3 39.0
0 0
5m 4m 3m 2m 1m 0 5m 4m 3m 2m 1m 0

ARNU09GQAA2
Cooling Heating
Discharge angle:40° Discharge angle:50°

Air velocity [m/s] 2.7m


Air velocity [m/s]
0.3 0.3 0.2 0.3 2.7m
2

0.3
0.

0.5
0.2
0.3 0.5
0.3
0.2
0.2

0.3
0.3

2m

0.5
2m
0.2
0.2
0.3

0.2
0.3
0.

0.3
0.3

0.2
2

03

0.2
0.2

0.3

0.5
0.2
0.3

1m 0.3
1m
0.2

2.5
0.
2

0.2
0.2

0.2

0.2 0.3
0.2
0.

0.2
0.2
2

0.3
0.

0.2 0.2 0.2


2

0.2

0.2
0.2 0.2
0.3 0. 0.2
2
2

0.2

0.2
0.

0.2 0.3 1.5 0.3 0.5


0 02 0
5m 4m 3m 2m 1m 0 5m 4m 3m 2m 1m 0

Temperature [°C] Temperature [°C]


13.9 13.5 13.5
2.7m 39.2 39.9 2.7m
.2 40.6
39
.5
14

13.5 40.6
13.9

40.6

2m 2m
14.5

14.5
40.0
39.9

0.0
39.2

4
40.6

13.9

39.9
43.0
12.0

13.9 13.9 1m 39.9


1m
13.9 39.9
43.0
.5

13.912.0 9
9.
14

39

3
.9

14.5
.9
13

39.9

13.9 13.9
13.5 40.6
40

13 40 40.0
.5 .6
.0

13.5 39.2 40.0


12.0 43.0
0 0
5m 4m 3m 2m 1m 0 5m 4m 3m 2m 1m 0

Console _ 11
7. Air Velocity and Temperature Distribution(Reference Data)
ARNU12GQAA2
Cooling Heating
Discharge angle:40° Discharge angle:50°

Air velocity [m/s] 2.7m


Air velocity [m/s]
0.2 0.5 0.4 0.4 2.7m
0.5

0.4
2
2

0.
0.

0.5 0.4

0.5
0.2
0.3

0.2
2m 2m
0.3 0.2 0.2
0.2

0.4
0.3

0.4
0.5
0.2 0.2
0.2

0.2
0.4

0.4
0.2
0.5

0.5
0.2
0.3

1.3
1m 2.2
1m
0.2

0.2
0.3 0.4

0.
0.2

0.2
0.2 0.2

0.
2
0.

0.2 0.2 0.2 0.2


2

0.2
0.3 0.2
0.5 0.2 0.2
0.5 0.4 0.2
0.2 0.2 1.3 0.2
0.4 0.4
0 0
5m 4m 3m 2m 1m 0 5m 4m 3m 2m 1m 0

Temperature [°C] Temperature [°C]


13.6 12.1
13.5
2.7m 42.5 42.6 43.3
2.7m
13.6
.5

42.5
13

43.3

42.5
.8
Indoor Units

42
2m 42.8 2m
13.5

13.6
42 42.5
13.5

.8

43.3
13
.5 42.5
13

43.3
11.5
.5

42.6
42.5 46.3
13.5

13.6 11.5
1m 1m
13.5
11.5 42.6
46.3
42.5
13

.5
13
.6

42.5
13

43.3
13 13
.6

.5 .5
43.3
42.8
.3
13.6 13.5 42.5 43
0 0
5m 4m 3m 2m 1m 0 5m 4m 3m 2m 1m 0

ARNU15GQAA2
Cooling Heating
Discharge angle:40° Discharge angle:50°

Air velocity [m/s] 2.7m


Air velocity [m/s]
0.2
0.4 0.2 0.2 0.3 0.6 2.7m
0.4

0.3

0.2 1.0
2
0.

1.0
0.4 0.4 0.6
0.2
0.2

1.0
0.6
2m 2m

0.2
0.2

0.3
0.2
0.3
0.2
0.4

0.2

1.0
0.4

0.4

0.4 0.3
0.6
0.2 0.3 0.3
0.2

1.9
0.2

1.0
1.0
0.2
0.2 1m 0.6 1m
0.3

0.4 0.3
0.4
0.3 0.3 2
3.6
1.9

0.
0.
0.2

0.3
2
0.

0.3
2

0.2 0 0.3 0.2


0.2 .2 0.3
0.3
0.4 0.2 0.3 0.2
0.2 1.9 0.6
0 0.6 03 0.6 0.2
0
5m 4m 3m 2m 1m 0 5m 4m 3m 2m 1m 0

Temperature [°C] Temperature [°C]


14.3 14.1 2.7m 2.7m
41

14.1 41.0 41.0 41.0


14.3
.0
.8
40
14.3

41.0
41.0

14.1 2m 2m
41.0
14
14.1

41.0

.1
40

14.2 .0 40.8
41
.9

.2
14
.3
14 14.3 12.4
40.9
.8

.8
40
43

14.3
14.1

1m 40.8 41.0 1m
41.0
12.4

40.8 43.8
14

14.2 14.3 40
.3

.8
41.0 40.8
.0
.1

41
14

14.3
40

40.9
14.3

.8

14.1 14.3
41.0
12.4
0 0
5m 4m 3m 2m 1m 0 5m 4m 3m 2m 1m 0

12 _ Console
8. Electric Characteristicss
Units Power Supply IFM Input(W)
Model Type Hz Volts Voltage Range MCA MFA kW FLA Cooling Heating
ARNU07GQAA2 QA 0.13 15 0.048 0.10 30 30
ARNU09GQAA2 QA Min.:198, 0.13 15 0.048 0.10 30 30
50 220-240
ARNU12GQAA2 QA Max.:264 0.13 15 0.048 0.10 30 30
ARNU15GQAA2 QA 0.13 15 0.048 0.10 30 30
ARNU07GQAA2 QA 0.13 15 0.048 0.10 30 30
ARNU09GQAA2 QA Min.:198, 0.13 15 0.048 0.10 30 30
60 220
ARNU12GQAA2 QA Max.:264 0.13 15 0.048 0.10 30 30
ARNU15GQAA2 QA 0.13 15 0.048 0.10 30 30

Symbols:
MCA : Minimum Circuit Amperes (A)

Indoor Units
MFA : Maximum Fuse Amperes(see note 5)
kW : Fan Motor Rated Output(kW)
FLA : Full Load Amperes(A)
IFM : Indoor Fan Motor

Note :
1. Voltage Range
Units are suitable for use on electrical system where voltage supplied to unit terminals is not below or above the
listed range limits.
2. Maximum allowable voltage unbalance between phase is 2%.
3. MCA/MFA
MCA = 1.25 x FLA
MFA ≤ 4 x FLA
( Next lower standard fuse rating. Minimum 15A)
4. Select wire size based on the larger value on the MCA.
5. Instead of fuse, use Circuit Breaker.

Console _ 13
9. Sound Levels
Overall
Notes:
1. Sound measured at each 1m away from the front and bottom of the unit
2. Operating condition
1m - Power source : 220-240V 50Hz / 220V 60Hz
Microphone - Cooling : Indoor temperature (27°C DB, 19°C WB),
Outdoor temperature (35°C DB, 24°C WB)

1m
- Heating : Indoor temperature (20°C DB, 15°C WB),
Outdoor temperature (7°C DB, 6°C WB)
3. Reference accoustic pressure 0dB = 20μPa
❈ Measuring place : Anechoic chamber 4. Sound level will vary depending on a range of factors such as
the construction(acoustic absorption coefficient) of particular
room in which the equipment in installed.

Sound Pressure Level


Sound Levels dB(A)
Model
H M L
ARNU07GQAA2 37 34 28
Indoor Units

ARNU09GQAA2 37 34 28
ARNU12GQAA2 39 34 28
ARNU15GQAA2 42 37 31

ARNU07GQAA2 ARNU09GQAA2 ARNU12GQAA2


80 80 80

70 70
Octave Band Sound Pressure Level (0dB = 20μPa)

70
Octave Band Sound Pressure Level (0dB = 20μPa)
Octave Band Sound Pressure Level (0dB = 20μPa)

NC-65 NC-65 NC-65


60 60 60

NC-60 NC-60 NC-60

NC-55 NC-55 NC-55


50 50 50

NC-50 NC-50 NC-50

NC-45 NC-45 NC-45


40 40 40

NC-40 NC-40 NC-40

NC-35 NC-35 NC-35


30 30 30

NC-30 NC-30 NC-30

20 NC-25 20 NC-25 20 NC-25


Approximate Approximate Approximate
NC-20 NC-20 NC-20
Hearing Hearing Hearing
Threshold Threshold Threshold
10 NC-15 10 NC-15 10 NC-15
63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

ARNU15GQAA2
80 80

70 70
Octave Band Sound Pressure Level (0dB = 20μPa)

Octave Band Sound Pressure Level (dB re 20Pa )

NC-65 NC-65
60 60
NC-60 NC-60

NC-55 NC-55
50 50

NC-50 NC-50

NC-45 NC-45
40 40

NC-40 NC-40

NC-35 NC-35
30 30

NC-30 NC-30

20 NC-25 20 NC-25
Approximate Approximate
NC-20 NC-20
Hearing Hearing
Threshold Threshold
10 NC-15 10 NC-15
63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

14 _ Console
10. Installation
• Please read this instruction sheet completely before installing the product.
• When the power cord is damaged, replacement work shall be performed by authorized personnel only.
• Installation work must be performed in accordance with the national wiring standards by authorized personnel only.

10.1 Selection of the Best Location


• There should not be any heat source or steam near the unit.
• There should not be any obstacles to the air circulation.
• A place where air circulation in the room will be good.
• A place where drainage can be easily obtained.
• A place where noise prevention is taken into consideration.
• Do not install the unit near the door way.
• Ensure the spaces indicated by arrows from the wall, ceiling, or other obstacles.
• The indoor unit must have the maintenance space.

Indoor Units
More than 300

More than
300

More than
300

250 or below
from the Floor
(Unit : mm)

In case that the unit is installed near the sea, the installation parts may be corroded
by salt. The installation parts (and the unit) should be taken appropriate anti-corro-
sion measures.

Console _ 15
10. Installation
10.2 Indoor unit installation
1. Preparation / Removing front panel
1. Open the front grille by pulling forward
2. Then pull out the link of grille from groove in front panel.
3. Then pull out 2 hinges of grille from grooves in front panel.
4. Then remove 4 screws, dismount the front panel while pulling it forward.
Indoor Units

2. Preparation / For Moldings , Side Piping, and Concealed Installation


2-1 For Moldings
1. Remove the slit portions on the Rear Panel.

Remove

Upper Deco cover

Side Deco cover


2-2 For Concealed Installation
1. Remove the 6 screws.
2. Remove the Upper Deco cover.
3. Remove the Side Deco covers.

2-3 For Side Piping (Reference 2-2.)


1. Remove the Deco Covers.
2. Remove the slit portions
3. Assemble the Deco Covers.

16 _ Console
10. Installation
3. Refrigerant Piping
1. The location of hole is different depending on which side of the pipe is taken out.
2. Drill a hole(Ø70mm) in the point indicated by symbol in the illustration as below

Wall
45

60
Left bottom piping 90 75 Right bottom piping

40

Left back piping 90 75 Right back piping Right back piping

Indoor Units
45

45

50
Left/right piping
(Unit : mm)

NOTICE
- The suggested shortest pipe length is 5m,in order to avoid noise from the outdoor unit and vibration.

4. Installing Indoor unit


4-1 Installation on the Floor.
1. Fix up using 6 screws for floor installation.

64 (700)
26

159
180

647
140

140

(600)
574
170

0
21
170

30.5
0
16
6 screw (M4*25L)
30.5

(Unit : mm)

Console _ 17
10. Installation
4-2 Installation on the Wall
1. Fix up the installation plate using 5 screws and the indoor unit using 4 screws.
2. The installation plate should be fixed on a wall which can support the weight of the indoor unit.

Installation Plate
Indoor Units

4 screw (M4*25L) Molding

4-3 Half concealed installation.


1. Make a wall hole of the size shown Fig-1.

Wall 45 Supplemental plate 95 Supplemental plate


670 (Field supply) (Field supply)

Hole

200 200

585

150 150

(Unit : mm)
<Fig - 1>
1) Normal concealed 2) Deep concealed

18 _ Console
10. Installation
2. Installation of supplemental plate for attaching main unit
• The rear of the unit can be fixed with screws at the points shown in the Fig-2.Be sure to install the
supplemental plate in accordance with the depth of the inner wall.

647

140 140

170 170

(Unit : mm)

Indoor Units
<Fig - 2>

3.Piping Hole
Wall
Left bottom Piping Right bottom Piping
50

35

Left Piping
Wall

45
75 75 50
(Unit : mm)
4. Remove the Deco Covers and Fixing Indoor
Unit
1) Remove the Deco Covers.
2) Insert the Indoor Unit to the Wall hole.
3) Secure using 6 screws. (shown in the illus-
tration)

Console _ 19
10. Installation
NOTICE

- Check the horizon of Indoor unit with the wall. Please use the Leveler on the drain pan guide.

Leveler
Drain pan
Less than 5mm
Indoor Units

Less than 5mm Less than 5mm

20 _ Console
10. Installation
10.3 Connecting the Piping
When you connect the refrigerant pipe, it is easier that you connect the gas pipe first.
1. Hold up the Sensor Link.
2. Separate the Pipe Bracket (2 screws)
3. Connect the refrigerant pipe. (Refer to next page)
4. Assemble the Pipe Bracket (2 screws)
5. Put down the Sensor Link

1 2 3

Indoor Units
4 5

6. After connecting, check the pipe arrangement as per illustration.


7. The piping can be arranged in six ways as shown in the illustration below.

6 7 8

Pipe Guide
3
Connecting
Pipe

2
1
Pipe Guide 6
4
Connecting Pipe must be placed inner
than the pipe guide.
5

In case of ➂ ~ ➅ , The pipe bending can be used in hand-operated bending machine.


Make a pipe of the shape shown pic 8.
Console _ 21
10. Installation

If the drain hose is routed inside the room insu-


late the hose with an insulation material* so
that dripping from sweating (condensation) will
not damage furniture or floors.
Tape
* Foamed polyethylene or equivalent is recom-
Connecting
mended. cable
Drain hose
Connecting pipe

Connecting the installation pipe and


drain hose to the indoor unit.
1. Align the center of the pipes and sufficiently
tighten the flare nut by hand. Indoor unit tubing Flare nut Pipes
Indoor Units

2. Tighten the flare nut with a wrench


Open-end wrench (fixed)

Flare nut

Wrench Connection pipe

Indoor unit tubing

3. When needed to extend the drain hose of


Drain pipe
indoor unit, assembly the drain pipe as shown
on the drawing
Indoor unit drain hose

Vinyl tape(narrow)
Adhesive

Wrap the insulation material around Insulation material


the connecting portion.
1. Overlap the connection pipe insulation material
and the indoor unit pipe insulation material.
Bind them together with vinyl tape so that there
may be no gap. Connection pipe Indoor unit pipe

2. Wrap the area which accommodates the rear Vinyl tape (wide) Wrap with vinyl tape
piping housing section with vinyl tape. Connecting cable

Pipe
3. Bundle the piping and drain hose together by Vinyl tape(narrow)
wrapping them with vinyl tape sufficient enough Wrap with vinyl tape
to cover where they fit into the rear piping
Pipe
housing section.

Vinyl tape(wide)
Drain hose

22 _ Console
10. Installation
10.4 Wiring Connection
• Connect the wires to the terminals on the control board individually according to the outdoor unit connection.
• Ensure that the color of the wires of outdoor unit and the terminal No. are the same as those of indoor unit respectively.

[Type 1]
Terminal block of indoor unit SODU B SODU A IDU B IDU A INT B INT A
1(L) 2(N) 3(A) 4(B)

Indoor power input


220V 60Hz

[Type 2] Terminal block of outdoor unit


Terminal block of indoor unit Outdoor unit Indoor unit Central controller

Indoor Units
1(L) 2(N) 3(A) 4(B) SODU SODU IDU IDU INTERNET DRY1 DRY2 GND 12V

Indoor power input


220V 60Hz

Make sure that the screws of the terminal are free from looseness.

After the confirmation of the above conditions, prepare the wiring as follows:
1) Never fail to have separate power specially for the air conditioner. As for the method of wiring, follow the cir-
cuit diagram pasted on the inside of control box cover.
2) Provide a circuit breaker switch between power source and the unit.
3) The screw which fasten the wiring in the casing of electrical fittings are liable to come loose from vibrations to
which the unit is subjected during the course of transportation. Check them and make sure that they are all
tightly fastened. (If they are loose, it could give rise to burn-out of the wires.)
4) Confirm the Specification of power source
5) Confirm that electrical capacity is sufficient.
6) Be sure that the starting voltage is maintained at more than 90 percent of the rated voltage marked on the
name plate.
7) Confirm that the cable thickness is as specified in the power sources specification.
(Particularly note the relation between cable length and thickness.)
8) Do not install the leakage breaker in a place which is wet or moist.
Water or moist may cause short circuit.
9) The following troubles would be caused by voltage drop-down.
• Vibration of a magnetic switch, damage on the contact point there of, fuse breaking, disturbance to the normal function
of a overload protection device.
• Proper starting power is not given to the compressor.

Console _ 23
10. Installation
WIRED REMOTE CONTROLLER INSTALLATION
• Since the room temperature sensor is in the remote controller, the remote controller box should be installed in a place
away from direct sunlight, high humidity and direct supply of cold air to maintain proper space temperature.
Install the remote controller about 5ft(1.5m) above the floor in an area with good air circulation at an average tempera-
ture.
Do not install the remote controller where it can be affected by:
- Drafts, or dead spots behind doors and in corners.
- Hot or cold air from ducts.
- Radiant heat from sun or appliances.
- Concealed pipes and chimneys.
- Uncontrolled areas such as an outside wall behind the remote controller.
- This remote controller is equipped with a seven segment LED. display. For proper display of the remote controller
LED's, the remote controller should be installed properly as shown in Fig.1.
(The standard height is 1.2~1.5 m from floor level.)
Indoor Units

Remote Controller
TEMP
yes

no
TEMP

Remote Controller

no
TEMP
5feet
Remote
Controller

(1.5meters)
no

Fig.1 Typical locations for remote controller

24 _ Console
11. Accessories
Standard Accessories

Clamp
Name Drain Hose Install Plate Other
(Tie wrap)

Quantity 1 EA 1 EA 4 EA
- Allergy Filter
- Fixing screw for installation
Plate 4*25 mm-5EA
- Wood screw for indoor
fixation -6EA
Shape - Owner's Manual
- Installation Manual

Indoor Units

Console _ 25
Indoor unit

Fresh Air Intake Unit


1. List of functions

2. Specifications

3. Dimensions & Gravity point

4. Piping Diagrams

5. Wiring Diagrams

6. Capacity tables and air flow

7. External Static Pressure(E.S.P) & Air Flow

8. Electric Characteristics

9. Sound Levels

10. Operation range

11. Installation

12. Accessories
1. List of functions
Category Function ARNU48GBRZ2, ARNU76GB8Z2, ARNU96GB8Z2

Air supply outlet 1


Airflow direction control(left & right) -
Airflow direction control(up & down) -
Auto swing(left & right) -
Auto swing(up & down) -
Air flow
Airflow steps(fan/cool/heat) 2/2/2
Chaos swing -
Chaos wind(auto wind) -
Jet cool(Power wind) -
Swirl wind -
Deodorizing filter X
Air purifying Plasma air purifier X
Prefilter(washable / anti-fungus) O
Drain pump O
E.S.P. control O
Installation
Electric heater(operation) X
Indoor Units

High ceiling operation -


Hot start O
Reliability Self diagnosis O
Soft dry operation O
Auto changeover -
Auto cleaning X
Auto operation(artificial intelligence) O(only heat pump or cooling only)
Auto restart operation O
Child lock O
Convenience Forced operation -
Group control O
Sleep mode X
Timer(on/off) O
Timer(weekly) O
Two thermistor control X
Wide wired remote controller PQRCVSL0/PQRCVSL0QW
Deluxe wired remote controller X
Individual
Simple wired remote controller PQRCVCL0Q(W)
control
Wired remote controller(for hotel use) PQRCHCA0Q(W)
Wireless LCD remote control PQWRH(C)Q0FDB
Zone control -
CTIE -
Special Electro thermostat -
function kit Remote temperature sensor PQRSTA0
Group control wire PZCWRCG3
Dry contact PQDSA(1)/PQDSB(1)/PQDSBC/PQDSBNGCM1/PQDSBCGCD0

O : Applied X : Not applied – : No relation


Option : Model name & price are different according to options, and assembled in factory with main unit.
Accessory : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate
package.

1 _ Fresh Air Intake Unit


2. Specifications
Type Fresh Air Intake Unit
Model Unit ARNU48GBRZ2 ARNU76GB8Z2 ARNU96GB8Z2
kW 14.1 22.4 28
Cooling Capacity kcal/h 12,100 19,300 24,100
Btu/h 48,100 76,400 95,900
kW 13.5 21.4 26.7
Heating Capacity kcal/h 11,620 18,410 23,000
Btu/h 46,115 73,080 91,360
Casing Galvanized Steel Plate Galvanized Steel Plate Galvanized Steel Plate
mm 1,230 x 380 x 590 1,562 x 460 x 688 1,562 x 460 x 688
Dimensions(WxHxD) Body
inch 48-7/16 x 14-31/32 x 23-7/32 61-1/2 x 18-1/8 x 27-3/32 61-1/2 x 18-1/8 x 27-3/32
Coil Rows x Columns x FPI 3 x 13 x 19 3 x 20 x 19 3 x 20 x 19
Face Area m2 0.38 0.59 0.59
Type Sirocco Fan Sirocco Fan Sirocco Fan
Motor Output x Number W 195 x 1 375 x 1 375 x 1
Running Current A 0.78 1.36 2.15
Air Flow Rate(H/M/L) CMM 18.8/14.7/14.7 23.7/13.2/13.2 35.7/23.7/23.7
Fan
(High Mode-factory set) cfm 664/519/519 837/446/446 1261/837/837

Indoor Units
External Static Pressure mmAq(Pa) 18 22 22
Drive Direct Direct Direct
Motor type BLDC BLDC BLDC
Microprocessor, Microprocessor, Microprocessor,
Temperature Control Thermostat for cooling Thermostat for cooling Thermostat for cooling
and heating and heating and heating
Sound Absorbing Thermal Insulation Material Foamed polystrene Foamed polystrene Foamed polystrene
Air Filter Long Life Filter Long Life Filter Long Life Filter
Safety Device Fuse Fuse Fuse
Liquid Side mm(inch) Ø9.52(3/8) Ø9.52(3/8) Ø9.52(3/8)
Pipe Connections Gas Side mm(inch) Ø15.88(5/8) Ø19.05(3/4) Ø22.2(7/8)
Drain Pipe(Internal Dia.) mm 25 25 25
Net Weight kg(lbs) 45(99) 73(161) 73(161)
Noise Level(Sound Press, 1.5m, H/M/L) dB(A) 44/42/42 49/47/47 50/48/48
Power Supply Ø, V, Hz 1, 220 - 240, 50 1, 220 - 240, 50 1, 220 - 240, 50
1, 220, 60 1, 220, 60 1, 220, 60
Refrigerant Control EEV EEV EEV
Power cable mm2 CV1.5 x 3C CV1.5 x 3C CV1.5 x 3C
Transmission cable mm2 VCTF-SB1.0 ~ 1.5 x 2C VCTF-SB 1.0 ~ 1.5 x 2C VCTF-SB 1.0 ~ 1.5 x 2C
Notes:-
1. Capacities are based on the following conditions:
Cooling • Outdoor temp. 33°C[91.4°F]DB/ 28°C[82.4°F]WB
• Interconnecting Piping Length 7.5m Conversion Formula
• Level Difference of Zero kcal/h= kW x 860
Heating • Outdoor temp. 0°C[32°F]DB/ -2.9°C[26.78°F]WB Btu/h = kW x 3412
• Interconnecting Piping Length 7.5m
cfm = m3/min x 35.3
• Level Difference of Zero
2. Capacities are net capacities l/s = CMM x 1000/60
3. Due to our policy of innovation some specifications may be changed without prior notification
4. To be added for more available Models
5. Indoor Unit Connection
No Connection Condition Combination
Fresh Air Intake Units only are connected with 1) The total capacity of Fresh Air Intake Unit should be 50~100% of outdoor unit.
1 2) The max quantity of Fresh Air Intake unit is 2 Units.
outdoor units
1) The total capacity of indoor units (standard Indoor Unit + Fresh Air Intake Unit) should be 50~100% of out-
2 Mixture connection with general Indoor unit and door unit.
Fresh Intake Unit 2) The total capacity of Fresh Air Intake Unit should be less than 30% of the total capacity of indoor units.
6. EEV : Electronic Expansion Valve
7. Noise Level is Standard Mode
(for actual High Mode(factory set) condition, Noise Level may exceed the standard level by 1.5dBA)

Fresh Air Intake Unit _ 2


Indoor Units

Fresh Air Intake Unit


1,092 120 4

25
ARNU48GBRZ2

303
(unit : mm)
6 101
1,282 Number Name Descripition

3 _ Fresh Air Intake Unit


83
1,230 115 26 1 Liquid pipe connection Unit size(48k):ø9.52

72
2 Gas pipe connection Unit size(48k):ø15.88

123
221
198
3 Drain pipe connection Unit size(48k):ø25

312
R6
0

90
60 4 Power supply connection

477
590
5 Air discharge

122
144
1

298
2 6 Air suction

56
50 3
114

32
135
585 118 190
1,006 260
5
Note
3. Dimensions & Gravity point

1. Unit should be installed in compliance with the installation manual


in the product box.

178

140
2. Unit shall be grounded in accordance with the local regulations or

294
380
applicable national codes.

177
192
241 279

Gravity point

590
1,230

76, Seongsan-dong, Changwon City, Gyeongnam,


641-713, Korea CHASSIS CODE: BR
4 Fresh Air Intake Unit
1,400 115
ARNU76GB8Z2

20
ARNU96GB8Z2

440
2

70
6 120
460 1,622
1,565 3
0
99 14

58 1
18
(unit : mm)

122 60 70 64
Number Name Descripition
109

688
580
68 1 Liquid pipe connection Unit size(76k, 96k):ø19.05
358

407
Unit size(76k):ø19.05
2 Gas pipe connection Unit size(96k):ø22.2

64
728 3 Drain pipe connection Unit size(76k, 96k): ø22.2

30
1,122
3. Dimensions & Gravity point

4 Power supply connection


5 5 Air discharge
6 Air suction

318
292
Note

460
1. Unit should be installed in compliance with the installation manual

225
161
in the product box.
118 2. Unit shall be grounded in accordance with the local regulations or
293 329
applicable national codes.

Gravity point

695
1,562

76, Seongsan-dong, Changwon City, Gyeongnam,


641-713, Korea CHASSIS CODE: B8

Fresh Air Intake Unit _ 4


Indoor Units
4. Piping Diagrams

Th4 EEV
Filter
Cooling
Heating
Th3 Th2
Heat Exchanger
Distributor Filter

Th1
S

Filter Capillary Tube Solenoid Valve Check Valve

Fresh Air Intake Unit


Indoor Units

Refrigerant pipe connection port diameter


[Unit: mm(inch)]

MODEL GAS LIQUID

ARNU48GBRZ2 Ø15.88(5/8) Ø9.52(3/8)

ARNU76GB8Z2 Ø19.05(6/8) Ø9.52(3/8)

ARNU96GB8Z2 Ø22.2(7/8) Ø9.52(3/8)

LOC. Description
Th1 Inlet Air Thermistor
Th2 Pipe In Thermistor
Th3 Pipe Out Thermistor
Th4 Outlet Air Thermistor

5 _ Fresh Air Intake Unit


5. Wiring Diagrams
BR Chassis

Indoor Units
Accessory

B8 Chassis

Accessory

Fresh Air Intake Unit _ 6


6. Capacity tables and air flow
6.1 Capacity tables
ARNU48GBRZ2
Cooling
59℉WB
Outdoor air 63℉WB 69℉WB 73℉WB 79℉WB 82℉WB 86℉WB 90℉WB 95℉WB 100℉WB
temperature
15℃WB 17℃WB 20℃WB 23℃WB 26℃WB 28℃WB 30℃WB 32℃WB 35℃WB 38℃WB
℉DB ℃DB TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
70 21 5.1 3.6 5.4 3.2 8.5 3.2 - - - - - - - - - - - - - -
73 23 5.1 4.3 5.2 3.9 8.2 3.7 - - - - - - - - - - - - - -
77 25 5.1 5.0 5.2 4.6 8.0 4.4 11.0 4.6 - - - - - - - - - - - -
81 27 5.0 5.0 5.1 5.1 7.3 5.1 10.9 4.8 14.0 4.5 - - - - - - - - - -
84 29 4.9 4.9 5.0 5.0 7.0 5.8 10.5 6.5 13.7 4.8 15.5 5.0 - - - - - - - -
88 31 4.9 4.9 5.0 5.0 6.7 6.5 9.5 6.0 13.3 5.5 15.1 5.3 16.3 4.6 - - - - - -
91 33 4.8 4.8 4.9 4.9 6.5 6.3 9.4 6.7 13.0 6.1 14.1 5.6 16.1 4.8 17.7 5.0 - - - -
96 35 4.8 4.8 4.9 4.9 6.4 6.4 9.2 7.4 12.7 6.8 14.0 6.2 15.9 5.5 17.5 5.2 - - - -
Indoor Units

99 37 4.7 4.7 4.8 4.8 6.3 6.3 9.1 8.5 11.8 7.4 13.7 6.9 15.3 6.2 17.3 5.6 18.9 5.4 - -
104 40 4.7 4.7 4.8 4.8 6.2 6.2 9.0 8.8 11.4 8.5 13.4 7.0 15.0 7.2 17.1 6.7 18.7 5.7 21.7 4.6
109 43 - - 4.7 4.7 6.1 6.1 8.9 8.9 11.0 9.0 13.0 7.5 14.5 8.5 16.5 7.7 18.4 6.7 20.9 5.5
113 45 - - 4.1 4.1 5.7 5.7 8.4 8.4 10.2 9.5 12.2 8.2 13.9 9.2 16.0 8.2 17.1 7.1 19.5 6.0
118 48 - - - - 5.2 5.2 8.1 8.1 10.5 9.8 11.3 9.2 13.0 9.9 15.2 9.3 16.6 6.9 18.5 6.9

Heating
Outdoor 19℉WB 23℉WB 27℉WB 32℉WB 36℉WB 39℉WB 43℉WB 50℉WB 57℉WB
air temperature -7℃WB -5℃WB -2.9℃WB 0℃WB 2℃WB 4℃WB 6℃WB 10℃WB 14℃WB
℉DB ℃DB TC TC TC TC TC TC TC TC TC
23 -5 14.7 - - - - - - - -
27 -3 14.2 14.4 - - - - - - -
32 0 - 14.0 14.2 - - - - - -
37 3 - - 13.6 13.8 14.0 - - - -
45 7 - - - 12.3 12.5 12.7 12.6 - -
52 11 - - - - 10.8 11.0 11.2 11.3 -
59 15 - - - - - 9.5 9.7 9.9 10.1
64 18 - - - - - - 8.7 8.9 9.0
68 20 - - - - - - 7.8 8.0 8.1

Note)
TC: Total Capacity (kW), SHC: Sensible Heat Capacity (kW)
WB: Wet Bulb, DB: Dry Bulb
1. The data shown in the graph illustrates the supported operating ranges underthe following conditions:
- Indoor and Outdoor Unit
- Effective piping length: 7.5 m
- Height differential: 0 m
2. The actual temperature may not match the temperature setting under some circumstances due to
the outdoor-air processing load or mechanical protection controls.
3. The system will not operate in fan mode when the outdoor air temperature is -5°C or below.
4. Tropical region only.

7 _ Fresh Air Intake Unit


6. Capacity tables and air flow
ARNU76GB8Z2
Cooling
59℉WB
Outdoor air 63℉WB 69℉WB 73℉WB 79℉WB 82℉WB 86℉WB 90℉WB 95℉WB 100℉WB
temperature
15℃WB 17℃WB 20℃WB 23℃WB 26℃WB 28℃WB 30℃WB 32℃WB 35℃WB 38℃WB
℉DB ℃DB TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
70 21 8.0 5.2 9.5 5.2 12.6 5.3 - - - - - - - - - - - - - -
73 23 7.9 6.1 9.0 6.1 12.4 5.7 - - - - - - - - - - - - - -
77 25 7.8 7.0 8.7 7.0 12.0 6.7 16.0 6.4 - - - - - - - - - - - -
81 27 7.7 7.2 8.8 7.9 11.8 7.5 15.7 6.9 19.6 6.9 - - - - - - - - - -
84 29 7.6 7.4 8.6 8.0 11.5 8.4 15.3 7.7 19.4 7.3 23.5 7.2 - - - - - - - -
88 31 7.5 7.5 8.5 8.1 11.4 9.4 15.0 8.6 19.2 8.2 23.0 7.7 24.2 7.2 - - - - - -
91 33 7.5 7.5 8.4 8.3 11.1 9.7 14.7 9.5 18.9 9.1 22.4 8.5 23.8 7.6 27.0 7.5 - - - -
96 35 7.4 7.4 8.4 8.4 10.9 10.1 14.4 10.4 18.7 9.9 21.5 9.3 23.1 8.3 26.7 8.1 - - - -
99 37 7.4 7.4 8.3 8.3 10.5 10.4 14.0 11.0 18.4 10.8 20.9 10.1 22.9 9.2 26.4 8.7 31.9 8.7 - -
104 40 7.3 7.3 8.3 8.3 10.5 10.5 13.5 12.1 17.6 12.0 20.8 11.5 22.5 10.5 26.2 10.1 31.2 9.3 34.4 7.2

Indoor Units
109 43 - - 8.1 8.1 10.4 10.4 12.9 12.8 17.0 12.9 20.1 11.9 22.4 11.5 25.2 11.0 30.0 10.3 33.5 8.7
113 45 - - 7.7 7.7 10.1 10.1 12.5 12.5 16.2 13.7 19.5 12.8 21.6 12.1 24.3 11.9 25.2 9.9 30.3 8.9
118 48 - - - - 9.5 9.5 12.1 12.1 15.7 14.2 18.7 13.4 20.9 12.9 23.6 12.5 21.3 10.4 25.3 9.1

Heating

Outdoor 19℉WB 23℉WB 27℉WB 32℉WB 36℉WB 39℉WB 43℉WB 50℉WB 57℉WB
air temperature -7℃WB -5℃WB -2.9℃WB 0℃WB 2℃WB 4℃WB 6℃WB 10℃WB 14℃WB
℉DB ℃DB TC TC TC TC TC TC TC TC TC
23 -5 23.8 - - - - - - - -
27 -3 22.4 22.6 - - - - - - -
32 0 - 21.2 21.4 - - - - - -
37 3 - - 17.9 18.1 18.2 - - - -
45 7 - - - 16.1 16.3 16.5 16.7 - -
52 11 - - - - 14.3 14.5 14.7 14.9 -
59 15 - - - - - 12.6 12.8 13.0 13.2
64 18 - - - - - - 11.4 11.6 11.8
68 20 - - - - - - 10.7 10.9 11.1

Note)
TC: Total Capacity (kW), SHC: Sensible Heat Capacity (kW)
WB: Wet Bulb, DB: Dry Bulb
1. The data shown in the graph illustrates the supported operating ranges underthe following conditions:
- Indoor and Outdoor Unit
- Effective piping length: 7.5 m
- Height differential: 0 m
2. The actual temperature may not match the temperature setting under some circumstances due to
the outdoor-air processing load or mechanical protection controls.
3. The system will not operate in fan mode when the outdoor air temperature is -5°C or below.
4. Tropical region only.

Fresh Air Intake Unit _ 8


6. Capacity tables and air flow
ARNU96GB8Z2
Cooling
59℉WB
Outdoor air 63℉WB 69℉WB 73℉WB 79℉WB 82℉WB 86℉WB 90℉WB 95℉WB 100℉WB
temperature
15℃WB 17℃WB 20℃WB 23℃WB 26℃WB 28℃WB 30℃WB 32℃WB 35℃WB 38℃WB
℉DB ℃DB TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
70 21 10.2 6.9 13.2 6.9 17.1 7.2 - - - - - - - - - - - - - -
73 23 10.0 8.3 12.8 8.0 16.7 7.8 - - - - - - - - - - - - - -
77 25 9.8 9.0 12.1 9.0 16.1 9.2 22.3 9.0 - - - - - - - - - - - -
81 27 9.7 9.2 11.4 10.3 15.6 10.5 21.5 9.5 27.4 9.7 - - - - - - - - - -
84 29 9.5 9.3 11.2 10.6 15.2 11.8 20.9 10.8 26.9 10.1 30.2 9.3 - - - - - - - -
88 31 9.4 9.4 11.1 10.7 15.2 13.3 20.4 12.1 26.6 11.5 29.8 10.0 33.8 10.1 - - - - - -
91 33 9.4 9.4 11.0 10.8 14.8 13.7 20.0 13.5 26.1 12.8 28.0 10.6 33.2 10.6 38.0 11.2 - - - -
96 35 9.3 9.3 11.0 11.0 14.6 14.1 19.5 14.8 25.8 14.1 27.6 11.9 32.1 11.7 37.6 11.7 - - - -
99 37 9.3 9.3 10.9 10.9 14.5 14.3 19.0 15.7 25.4 15.4 26.6 13.1 31.8 13.0 37.0 12.2 44.2 12.9 - -
104 40 9.2 9.2 10.9 10.9 14.4 14.4 18.7 17.2 24.2 16.8 25.8 15.2 31.2 15.0 36.6 14.3 43.9 13.2 52.3 12.4
Indoor Units

109 43 - - 10.8 10.8 14.3 14.3 18.5 18.0 23.8 17.4 25.0 16.4 29.7 16.0 34.4 15.6 42.4 14.7 50.5 13.1
113 45 - - 10.3 10.3 13.9 13.9 18.0 18.0 22.9 18.2 24.2 17.2 28.8 16.7 33.4 16.2 37.9 14.9 45.6 13.4
118 48 - - - - 13.4 13.4 17.2 17.2 22.0 19.0 23.4 18.0 27.9 17.8 32.7 17.2 32.3 15.6 38.0 13.7

Heating
Outdoor 19℉WB 23℉WB 27℉WB 32℉WB 36℉WB 39℉WB 43℉WB 50℉WB 57℉WB
air temperature -7℃WB -5℃WB -2.9℃WB 0℃WB 2℃WB 4℃WB 6℃WB 10℃WB 14℃WB
℉DB ℃DB TC TC TC TC TC TC TC TC TC
23 -5 28.6 - - - - - - - -
27 -3 28.2 28.4 - - - - - - -
32 0 - 26.5 26.7 - - - - - -
37 3 - - 25.8 26.0 27.7 - - - -
45 7 - - - 25.1 25.3 25.0 24.4 - -
52 11 - - - - 21.7 21.9 22.1 22.5 -
59 15 - - - - - 19.4 19.6 19.8 19.6
64 18 - - - - - - 17.4 17.6 17.9
68 20 - - - - - - 16.0 16.2 16.4

Note)
TC: Total Capacity (kW), SHC: Sensible Heat Capacity (kW)
WB: Wet Bulb, DB: Dry Bulb
1. The data shown in the graph illustrates the supported operating ranges underthe following conditions:
- Indoor and Outdoor Unit
- Effective piping length: 7.5 m
- Height differential: 0 m
2. The actual temperature may not match the temperature setting under some circumstances due to
the outdoor-air processing load or mechanical protection controls.
3. The system will not operate in fan mode when the outdoor air temperature is -5°C or below.
4. Tropical region only.

9 _ Fresh Air Intake Unit


6. Outlet temperature, expected capacity and air flow
6.2 Air flow
ARNU48GBRZ2
Setting ESP (mmAq)
Value 5 6 8 10 12 14 15 16 17 18 20
70 15.8 - - - - - - - - - -
75 18.7 16 - - - - - - - - -
80 22.2 19.9 13.6 - - - - - - - -
85 24.2 23.4 17.8 - - - - - - - -
87 25.2 24.1 19.6 - - - - - - - -
90 26.8 25.5 21.9 15.9 - - - - - - -
92 28.1 27 22.8 18.2 10.6 - - - - - -
94 29 27 24 19.8 13.8 - - - - - -
96 30.3 28.5 25 22.5 15.8 - - - - - -
98 - 29.8 26.5 22.8 17.4 10.7 - - - - -
101 - 31.8 28 24.2 20.5 16 - - - - -
103 - 32.7 29.17 25.9 22 16.5 11.8 - - - -
106 - - 30.9 28.2 24.6 19.9 15.2 11.9 - - -

Indoor Units
111 - - - 30.8 28.3 24.2 20.7 17.7 15.8 14.7
116 - - - - 30.7 27.6 25.2 24.2 22.4 18.8 13.4
121 - - - - - 30.4 29.7 27.2 26.3 25.6 18.7
126 - - - - - - - 28.6 27.6 27.4 25.9
130 - - - - - - - - - 26.5
135 - - - - - - - - - - -
140 - - - - - - - - - - -

ARNU76GB8Z2, ARNU96GB8Z2
Setting ESP (mmAq)
Value 6 9 12 15 18 20 22 23 25
55 25.39 - - - - - - - -
60 33.65 - - - - - - - -
65 40.01 30.29 - - - - - - -
70 46.43 35.81 17.31 - - - - - -
75 50.93 45.35 35.57 - - - - - -
80 55.77 51.91 42.86 26.57 - - - - -
85 - 54.22 49.74 42.67 20.9 - - - -
88 - - 52.72 46.44 33.72 - - - -
90 - - 52.54 48.82 40.09 23.07 - - -
92 - - - 50.91 44.3 23.46 - - -
94 - - - 50.9 46.73 39.65 13.87 - -
96 - - - - 49.84 44.04 24.17 23.63 -
98 - - - - 49.66 48.09 39.72 25.28 14.49
100 - - - - - 48.23 42.56 40.34 15.47
102 - - - - - - 46.41 45.92 38.6
105 - - - - - - - 46.51 45.44

Note) Setting Value : ESP value


The above table shows the correlation between the air rates and E.S.P.
The above table shows the available E.S.P. range.
If the E.S.P. of the installed indoor is less than the lowest value(as mention in the table), indoor components can be failed.

Fresh Air Intake Unit _ 10


7. External Static Pressure (E.S.P) & Air Flow
ARNU48GBRZ2
Capacity Mode Set value Standard Lower Limit of External Upper Limit of External
(Btu/h) ESP(mmAq(Pa)) CMM Static Pressure(mmAq(Pa)) Static Pressure(mmAq(Pa))

High High 116 18.8


48k 18 10(98) 20(196)
(factory set) Mid 110 14.7

ARNU76GB8Z2, ARNU96GB8Z2
Capacity Mode Set value Standard Lower Limit of External Upper Limit of External
(Btu/h) ESP(mmAq(Pa)) CMM
Static Pressure(mmAq(Pa)) Static Pressure(mmAq(Pa))
High High 95 23.7
76k 22 12(118) 25(245)
(factory set) Mid 93 13.2
High High 97 35.7
96k 22 12(118) 25(245)
(factory set) Mid 95 23.7
Indoor Units

Note) The above table shows the available E.S.P. range.

11 _ Fresh Air Intake Unit


8. Electric Characteristics
Units Power Supply IFM Input(W)
Model Type Hz volts Voltage Range MCA MFA kW FLA Cooling Heating
ARNU48GBRZ2 BR 1.5 15 0.20 0.78 169 169
ARNU76GB8Z2 B8 50 220-240 2.7 15 0.38 1.36 230 230
ARNU96GB8Z2 B8 Max: 264 3.7 15 0.38 2.15 360 360
ARNU48GBRZ2 BR Min: 198 1.5 15 0.20 0.78 169 169
ARNU76GB8Z2 B8 60 220 2.7 15 0.38 1.36 230 230
ARNU96GB8Z2 B8 3.7 15 0.38 2.15 360 360

Symbols: Note :
MCA : Min, Circuit Amps(A) 1. Voltage range
MFA : Max. Fuse Amps(see note 5) Units are suitable for use on electrical systems where voltage
supplied to unit terminals is not below or above the listed range
kW : Fan Motor Rated Output(kW)

Indoor Units
limits,
FLA : Full Load Amps(A)
2. Maximum allowable voltage unbalance between phases is 2%
IFM : Indoor Fan Motor
3. MCA/MFA
MCA=1.25 x FLA
MFA≤ 4 x FLA
(Next lower standard fuse rating. Min. 15A)
4. Select wire size based on the MCA
5. Instead of fuse, use Circuit Breaker.

Fresh Air Intake Unit _ 12


9. Sound Levels
Overall
Notes:
1. Sound measured at 1.5m away from the center of the unit
DISCHARGE SUCTION 2. Operating condition
- Cooling : Outdoor temp. (33°C DB, 28°C WB)
- Heating : Outdoor temp. (0°C DB, -2.9°C WB)
DUCT DUCT
3. Reference accoustic pressure 0dB = 20μPa
4. Sound level will vary depending on a range of factors such as
the construction(acoustic absorption coefficient) of particular
2m 1.5m room in which the equipment in installed.
1m

❈ Measuring place : Anechoic chamber

[dB(A)]
Sound Level
Model
H M L
Indoor Units

ARNU48GBRZ2 44 42 42
ARNU76GB8Z2 49 47 47
ARNU96GB8Z2 50 48 48

Sound Pressure Level


ARNU48GBRZ2 ARNU76GB8Z2 ARNU96GB8Z2
80 80 80

70 70 70
Octave Band Sound Pressure Level (0dB = 20μPa)
Octave Band Sound Pressure Level (0dB = 20μPa)

Octave Band Sound Pressure Level (0dB = 20μPa)

NC-65 NC-65 NC-65


60 60 60
NC-60 NC-60 NC-60

NC-55 NC-55 NC-55


50 50 50
NC-50 NC-50 NC-50

NC-45 NC-45 NC-45


40 40 40
NC-40 NC-40 NC-40

30 NC-35 NC-35 NC-35


30 30
NC-30 NC-30 NC-30

20 NC-25 20 NC-25 20 NC-25


Approximate Approximate Approximate
NC-20 NC-20 NC-20
Hearing Hearing Hearing
Threshold NC-15 Threshold Threshold
10 10 NC-15 NC-15
10
63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000
Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz) Octave Band Center Frequency (Hz)

13 _ Fresh Air Intake Unit


10. Operation Details
Operation range
FAU will operate in the below range. Hot outdoor temperature (over 43℃) or cold outdoor temperature (under -
5℃) will make customer feel uncomfortable because FAU outlet discharge temperature might be not enough con-
trolled in that region.
* FAU : Fresh Air Intake Unit
Outdoor Air Temperature (Toa) ℃
-5°C 5°C 15°C 19°C 43℃ (1)

Cooling mode Fan operation (thermo off) Cooling

Cooling
Fan operation
Fan stop
6°C 18°C

Heating mode Heating Fan operation (thermo off)

Fan operation
Heating

16°C

Indoor Units
Automatic mode Heating Cooling

Fan operation
(thermo off) Cooling

Heating 18°C
16°C

(1)Normal model : 43°C


Tropical model : 48°C

Usage Limitations

-5°C 15°C 19°C (33.5°) 43℃ (2)

(2)Normal model : 43°C


Tropical model : 48°C

Fresh Air Intake Unit _ 14


11. Installation

Air outlet vents Air filters

Air intake vents

Wired Remote Controller


Indoor Units

Standard Accessories
Washer for Clamp Insulation for
Name Drain hose Clamp metal hanging backet (Tie Wrap) fitting
Others
Quantity 1 EA 2 EA 8 EA 4 EA 1 SET

• Owner's manual
• Installation manual

Shape for gas pipe

for liquid pipe

15 _ Fresh Air Intake Unit


11. Installation
11.1 Installation Limit
Read completely, then follow step by step.
1. Fresh Air Intake Unit Combination
No Connection Condition Combination
Only Fresh Air Intake Unit installation 1) The total capacity of Fresh Air Intake Unit should be 50~100% of outdoor unit.
1 2) The max quantity of Fresh Air Intake unit is 2 Units.
1) The total capacity of indoor units (standard Indoor Unit + Fresh Air Intake Unit)
2 Mixture Installation with standard should be 50~100% of outdoor unit.
indoor units and Fresh Intake Units 2) The total capacity of Fresh Air Intake Units should be less than 30% the total
capacity of indoor units.

Failure to comply with the above connection conditions for installation, it can cause cooling &
heating capacity down.

2. Connection of the Outdoor Unit

Indoor Units
It is possible to connect Heat Pump Models.
It is not possible to connect Heat Recovery Models.
<Only Fresh Air Intake Unit install> <Mixture Install>
Outdoor : 10HP Outdoor : 20HP

FAU FAU FAU Standard Standard Standard

5HP 5HP 5HP 5HP 5HP 5HP

<Wrong Install>
Outdoor : 20HP

FAU Standard Standard Standard Standard

5HP 5HP 5HP 5HP 5HP


* FAU : Fresh Air Intake Unit
Standard: Standard Indoor Unit

ᶀ The total capacity of indoor units exceed 100% of outdoor unit

Fresh Air Intake Unit _ 16


11. Installation
3. Installation of intake air duct

Min. 2m

Inlet Hood
1/30 Slope
Intake Air Duct
Outlet Air Fresh Air Intake Unit
Exhaust Fan
Door
Exhaust air

Inlet Hood
Inlet Hood should be installed such that no water enter inside the unit
Intake Air Duct
The Intake Air Duct must have down-slope about 1/30.
The length of Intake Air Duct should be longer than 2m.
Fresh Air Intake Unit
Indoor Units

If wired remote controller is not connected, it will display strange value to the room temperature
Exhaust Fan
Fresh Air Intake Unit will make room the positive pressure.
Exhaust fan should be installed to maintain the room pressure.
Door
It would be possible to raise in the room air pressure because of Fresh Air Intake Unit.
In that case, the door could hurt someone in front of door.
So be careful of the positive pressure to design the door.

17 _ Fresh Air Intake Unit


11. Installation
4. The Control System
1) In case of connecting with Standard indoor units, Standard indoor unit should be a master unit.
Separate Fresh Air Intake Unit with Standard indoor units
.Set only one Standard indoor units to Master,

FAU Standard Standard Standard

Slave
Set one of the IDU to Master * FAU : Fresh Air Intake Unit
Standard: Standard Indoor Unit

Indoor Units
2) In case of using central remote controller, mixture of indoor units and Fresh Air Intake Unit in
same zone is not possible.
Separate Fresh Air Intake Unit zone with Standard indoor units zone.

FAU FAU Standard Standard FAU FAU Standard Standard


48 kBtu/h 48 kBtu/h 48 kBtu/h 48 kBtu/h 48 kBtu/h 48 kBtu/h 48 kBtu/h 48 kBtu/h

ZONE 1 ZONE 2 ZONE 1 ZONE 2

5. Cycle check and SVC


For Fresh Intake Unit cycle check and SVC, LG MV 5.8 or later version should be used.

Fresh Air Intake Unit _ 18


11. Installation
11.2 Selection of the best location
Install the air conditioner in the location that satisfies the following conditions.
• The place shall easily bear a load exceeding four times the indoor unitʼs weight.
• The place shall be able to inspect the unit as the figure.
• The place where the unit shall be leveled.
• The place shall allow easy water drainage.(Suitable dimension “H” is necessary to get a slope to drain as
figure.)
• The place shall easily connect with the outdoor unit.
• The place where the unit is not affected by an electrical noise.
• The place where air circulation in the room will be good .
• There should not be any heat source or steam near the unit.

Top view Inspection hole


(unit: mm) (600X600)
Control box
Indoor Units

1000

600 600

Front
Front view
(unit: mm)

H = 20 or more

CAUTION : In case that the unit is installed near the sea, the installation parts
may be corroded by salt, The installation parts (and the unit) should be taken
appropriate anti-corrosion measures.

19 _ Fresh Air Intake Unit


11. Installation
11.3 Ceiling dimension and hanging bolt location
Installation of Unit BR Chassis (48k)
A
Install the unit above the ceiling correctly.
B

CASE 1
POSITION OF SUSPENSION BOLT

C
E
• Apply a joint-canvas between the unit and duct to

D
absorb unnecessary vibration.
(G)

F
(Unit:mm)
Dimension
A B C D E F (G) H I

I
Capacity(Btu/h)
BR Chassis 1282 1230 477 56 590 30 120 1006 294
(48k) H
Drainage hole

Indoor Units
(Unit:mm) B8 Chassis (76/96k)

Dimension A
A B C D E F G H I J K L B K L
Capacity(Btu/h) F J
B8 Chassis
(76/96k) 1622 1565 580 292 695 1400 460 1122 1680 390 445 15
EC

CASE 2
• Install the unit leaning to a drainage hole side as a fig- GD
ure for easy water drainage.
H
POSITION OF CONSOLE BOLT I
• A place where the unit will be leveled and that can
support the weight of the unit.
• A place where the unit can withstand its vibration.
• A place where service can be easily performed. M10 Nut X4

M10 washer X4

M10 washer X4
M10 Nut X8

Fresh Air Intake Unit _ 20


11. Installation
NOTICE
• Throughly study the following installation locations:
1. In such places as restaurants and kitchens, considerable amount of oil steam and flour adhere to the fan, the
fin of the heat exchanger, resulting in heat exchange reduction, spraying, dispersing of water drops, etc.
In these cases, take the following actions:
• Make sure that the ventilation fan for smoke-collecting hood on a cooking table has sufficient capacity so that
it draws oily steam which should not flow into the suction of the air conditioner.
• Make enough distance from a cooking room to install the air conditioner in such a place where it may not suck
in oil steam.
2. Avoid installing air conditioner in such circumstances where cutting oil mist or iron powder is in suspension in
factories, etc.
3. Avoid places where inflammable gas is generated, flows in, is stored or vented.
4. Avoid places where sulfurous acid gas or corrosive gas is generated.
5. Avoid places near high frequency generators.
Indoor Units

11.4 Indoor Unit Installation


• Select and mark the position for fixing bolts. • Insert the set anchor and washer onto the suspen-
• Drill the hole for set anchor on the face of ceiling. sion bolts for locking the suspension bolts on the
ceiling.
• Mount the suspension bolts to the set anchor firmly.
• Secure the installation plates onto the suspension
bolts (adjust level roughly) using nuts, washers
and spring washers.

Old building New building

1 Set anchor
2 Plate washer
3 Spring washer
4 Nut
CAUTION : Tighten the nut and bolt 5 Suspension
to prevent unit falling. bolts

21 _ Fresh Air Intake Unit


11. Installation
11.5 Wiring Connection
Connect the wires to the terminals on the control board individually according to the outdoor unit connection.
• Ensure that the color of the wires of outdoor unit and the terminal No. are the same as those of indoor unit respectively.

• BR Chassis (48k)

[Type 1] [Type 2]

Terminal Block Indoor SODU B SODU A IDU B IDU A INT B INT A Terminal Block Indoor Outdoor unit Indoor unit Central controller
Outdoor unit
1(L) 2(N) 3(A) 4(B) 1(L) 2(N) 3(A) 4(B) SODU SODU IDU IDU INTERNET DRY1 DRY2 GND 12V

INDOOR POWER INPUT INDOOR POWER INPUT

• B8 Chassis (76/96k)

[Type 1] [Type 2]
Terminal Block Indoor Terminal Block SODU B SODU A IDU B IDU A INT B INT A Terminal Block Indoor Terminal Block Outdoor unit Indoor unit Central controller
Outdoor
1(L) 2(N) 3(A) 4(B) SODU SODU IDU IDU INTERNET DRY1 DRY2 GND 12V unit
1(L) 2(N) 3(A) 4(B)

Indoor Power Input Indoor Power Input

Indoor Units
WARNING : Make sure that the screws of the terminal are free from looseness.

Clamping of cables
1) Arrange 2 power cables on the control panel.
2) First, fasten the steel clamp with a screw to the inner boss of control panel.
3) For the cooling model, fix the other side of the clamp with a screw strongly. For the heat pump model, put the
0.75mm2 cable(thinner cable) on the clamp and tighten it with a plastic clamp to the other boss of the control panel.

INSULATION, OTHERS Insulate the joint and tubes completely.

THERMAL INSULATION All thermal insulation must comply with local requirement.

Union for liquid pipe Thermal insulator for refrigerant pipe


(Local supply) Thermal insulator for
Refrigerant pipe and thermal
piping(Local supply)
insulator(Local supply)

Hose crip for thermal insulator


(Local supply)
Overlap with thermal
Thermal insulator for refrigerant pipe insulator for piping.
(Local supply) Hose crip for thermal insulator(Local supply)
Union for gas pipe Make sure that there is no clearance here.

Fresh Air Intake Unit _ 22


11. Installation
11.6 Check the Drainage

2. Check the drainage.


• Spray one or two glasses of water upon the
evaporator.
• Ensure that water flows drain hose of indoor
unit without any leakage.
Indoor Units

CAUTION
1. Install declination of the indoor unit is very important for the drain of the duct type air conditioner.
2. Minimum thickness of the insulation for the connecting pipe shall be 5mm.

Front of view
• The unit must be horizontal or declined to the drain hose connected when finished installation.
Ceiling
1~3mm

Drain Pump unuse Drainage hole Drain Pump use Drainage hole

23 _ Fresh Air Intake Unit


11. Installation
11.7 Indoor Unit Drain Piping Upward
Pipe clamp
• Drain piping must have down-slope (1/50 to 1/100): be sure not to pro- routing
vide up-and-down slope to prevent reversal flow. not allowed

• During drain piping connection, be careful not to exert extra force on the Indoor unit
drain port on the indoor unit.
• The outside diameter of the drain connection on the indoor unit is 32mm.
Maintenance
drain port
Piping material: Polyvinyl chloride pipe inner
diameter Ø 25mm and pipe fittings
• Be sure to install heat insulation on the drain piping.
1/50~1/100

Heat insulation material: Polyethylene foam with MAX 700mm


thickness more than 8 mm.

Drain test

Indoor Units
The air conditioner uses a drain pump to drain water.
Use the following procedure to test the drain pump operation:
Feed water Flexible drain hose
(accessory) • Connect the main drain pipe to the exterior and leave it pro-
Main visionally until the test comes to an end.
drain pipe
• Feed water to the flexible drain hose and check the piping
Drain for leakage.
Drain Pump port Glue the joint
• Be sure to check the drain pump for normal operation and
Drain hose connection
Use the clip (accessory) noise when electrical wiring is complete.
• When the test is complete, connect the flexible drain hose to
the drain port on the indoor unit.
Drain pan

Hanger
Max 300mm distance Hanger Bracket
1~15m 1/50~1/100 slope
The supplied flexible drain hose should not be strained. Metal

Max 700mm
A strained hose may cause leakage of water. clamp

Flexible drain hose


Insulation

Flexible drain hose


Flexible drain hose

Flexible drain hose

Fresh Air Intake Unit _ 24


11. Installation

CAUTION:
After the confirmation of the above conditions, prepare the wiring as follows:
1) Never fail to have an individual power specialized for the air conditioner. As for the method of
wiring, be guided by the circuit diagram posted on the inside of control box cover.
2) Provide a circuit breaker switch between power source and the unit.
3) The screws which fasten the wiring in the casing of electrical fittings are liable to come loose
from vibrations to which the unit is subjected during the course of transportation. Check them
and make sure that they are all tightly fastened. (If they are loose, it could give rise to burn-out
of the wires.)
4) Specification of power source
5) Confirm that electrical capacity is sufficient.
6) Be sure that the starting voltage is maintained at more than 90 percent of the rated voltage
marked on the name plate.
7) Confirm that the cable thickness is as specified in the power sources specification.
(Particularly note the relation between cable length and thickness.)
8) Never fail to equip a leakage breaker where it is wet or moist.
Indoor Units

9) The following troubles would be caused by voltage drop-down.


• Vibration of a magnetic switch, damage on the contact point, fuse breaking, disturbance by the nor-
mal function of an overload protection device.
• Proper starting power is not given to the compressor.

HAND OVER
Teach the customer the operation and maintenance procedures, using the operation manual.
(air filter cleaning, temperature control, etc.)

25 _ Fresh Air Intake Unit


12. Accessories
Standard Accessories
Washer for Clamp Insulation for
Name Drain hose Clamp metal (Other)
hanging backet (Tie Wrap) fitting

Quantity 1 EA 2 EA 8 EA 4 EA 1 SET

• Owner's manual
• Installation manual

Shape for gas pipe

for liquid pipe

Indoor Units

CAUTION
• Use only those accessories (Standard or optional) which have designated specifications.

Fresh Air Intake Unit _ 26


Indoor unit
Dip Switch & Group Control Setting

1. Cassette, Duct, Ceiling & Floor, Ceiling Suspended, Floor


Standing, Console, Fresh Air Intake Unit
1.1 Dip Switch Setting
1.2 Group Control Setting
1.3 2 Remote Control
1.4 Accessories for group control setting

2. Wall Mounted, ART COOL Gallery, ART COOL Mirror


2.1 Master/Slave Setting
2.2 Group Control Setting
2.3 2 Remote Control
2.4 Accessories for group control setting
1. Cassette, Duct, Ceiling & Floor, Ceiling Suspended, Floor Standing, Console, Fresh Air Intake Unit
1.1 Dip Switch Setting
Dip Switch Setting of Indoor unit PCB

Function Description Setting Off Setting On Default


SW1 Communication N/A (Default) - - Off
SW2 Cycle N/A (Default) - - Off
Selection of Master or
SW3 Group Control Master Slave Off
Slave

Wired/Wireless remote
Selection of Dry Contact controller
SW4 Dry Contact Mode Auto Off
Mode selection of Manual or Auto
operation Mode
SW5 Installation Fan continuous operation Continuous operation Removal - Off
SW6 Heater linkage N/A - - Off
Selection of Ventilator
Ventilator linkage Linkage Removal Working
linkage
SW7 Vane selection Selection of up/down Up side Vane Off
Up side + Down side Vane
(Console) side Vane Only
Region selection Selection tropical region General model Tropical model
SW8 Etc. Spare - - Off

Group Control Setting


CAUTION

Dip Switch &


For Multi V Models, Dip switch 1, 2, 6, 8 must be set OFF.

Dip Switch & Group Control Setting _ 1


1. Cassette, Duct, Ceiling & Floor, Ceiling Suspended, Floor Standing, Console, Fresh Air Intake Unit
1.2 Group Control 1
(1) Group Control 1
n Wired remote controller 1 + Standard Indoor Units

LGAP Network System

GND
Master Slave Slave Slave Signal
12 V

Display Error Message Only connect serial signal and GND lines
between slave indoor unit

Master

n Dip Switch in PCB (Cassette and Duct Type indoor units)


Group Control Setting

¿ Master Setting ¡ Slave Setting


- No. 3 Off - No. 3 On
Dip Switch &

1. It is possible to 16 indoor units(Max) by one wired remote controller.


Set only one indoor unit to Master, set the others to Slave.
2. You can connect all the types of 2nd generation indoor units .
3. It is possible to use wireless remote controller at the same time.
4. It is possible to connect with Dry Contact and Central controller at the same time.
- The Master indoor unit is possible to recognize Dry Contact and Central Controller only.
- In case of Central controller and Group controller at the same time, it is possible to connect standard 2series indoor
units or later since Feb. 2009.
- In case of Central controller setting, the Central controller can control indoor units after setting only the address of
master indoor unit.
- Slave indoor unit will be operated like master indoor unit.
- Slave indoor unit can not be individually controlled by Central controller.
- Some remote controller canʼt perform with Dry Contact and Central controller at the same time. So contact us further
information about it.

2 _ Dip Switch & Group Control Setting


1. Cassette, Duct, Ceiling & Floor, Ceiling Suspended, Floor Standing, Console, Fresh Air Intake Unit
5. In case that the indoor unit has an abnormal problem an error code will be displayed on the wired remote
controller.
With the exception of the indoor unit with the error, you can control each indoor unit individually.

6. In case of Group Control, it is possible to use following functions.


- Selection of operation options (operation/stop/mode/set temperature)
- Control of flow rate (High/Middle/Low)
- It is not possible at some functions.

h Master/Slave setting of indoor units be set possible using a PCB Dip Switch.
h It is possible to connect indoor units since Feb. 2009.
In the other cases, please contact LGE.
hIt can be the cause of malfuctions when there is no setting of master and slave.

(2) Group Control 2


n Wired remote controllers + Standard Indoor Units

LGAP Network System

Group Control Setting


GND

Dip Switch &


Master Slave Slave Slave Signal
12 V

Donʼt connect serial 12V line

Display Error Message

Master Slave

h It is possible to control N indoor units by wired remote controller M units. (M+N≤17 Units)
Set only one indoor unit to Master, set the others to Slave.
Set only one wired remote controller to Master, set the others to Slave.
Other than those, it is same with the Group Control 1.

Dip Switch & Group Control Setting _ 3


1. Cassette, Duct, Ceiling & Floor, Ceiling Suspended, Floor Standing, Console, Fresh Air Intake Unit
(3) Group Control 3
n Mixture connection with indoor units and Fresh Air Intake Unit

LGAP Network System

GND
FAU FAU Master Slave Signal
Master
Master Slave 12 V

Display Error Message

Master Master

h In the case that you connect standard indoor units and Fresh Air Intake Units together, control them separately from
each other with different wired remote controllers.
h Other than those, it is same with Group Control 1.
Group Control Setting
Dip Switch &

FAU FAU Standard Standard FAU FAU Standard Standard

* FAU : Fresh Air Intake Unit


Standard: Standard Indoor Unit

4 _ Dip Switch & Group Control Setting


1. Cassette, Duct, Ceiling & Floor, Ceiling Suspended, Floor Standing, Console, Fresh Air Intake Unit
1.3 2 Remote Control
n Wired remote controller 2 + Indoor unit 1

LGAP Network System

Master

Display Error Message

Master Slave

1. It is possible to connect two wired remote controllers with one indoor unit.
2. You can connect any of the types of 2nd generation indoor units to two wired remote controllers.

Group Control Setting


3. It is possible to use wireless remote controller at the same time.
4. It is possible to connect with Dry Contact and Central controller at the same time.

Dip Switch &


5. In case that the indoor unit has an abnormal problem an error code will be displayed on the wired remote
controller.
With the exception of the indoor unit with the error, you can control each indoor unit individually.
6. There isn’t limits of indoor unit function
❈ Maximum 2wired remote controllers can be connected with 1 indoor unit.

Dip Switch & Group Control Setting _ 5


1. Cassette, Duct, Ceiling & Floor, Ceiling Suspended, Floor Standing, Console, Fresh Air Intake Unit
1.4 Accessories for group control setting
It is possible to set group control by using below accessories.

Indoor unit 2 EA +Wired remote controller Indoor unit 1 EA +Wired remote controller 2EA

h PZCWRCG3 cable used for connection h PZCWRC2 cable used for connection

Mas te r S lave

PZC WRC 2

PZC WRC G3

Maste r S lave
Maste r
Group Control Setting
Dip Switch &

6 _ Dip Switch & Group Control Setting


2. Wall Mounted, ART COOL Gallery, ART COOL Mirror
2.1 Master/Slave Setting
CAUTION
Installer setting mode is to set the detail function of the remote controller.
If the installer setting mode is not set correctly, it can cause problems to the product, user injury or property damage.
This must be set by an certificated installer, and any installation or change that is carried out by a non-certificated per-
son should be responsible for the results. In this case, free service cannot be provided.

When JET COOL button pressed, press RESET button


1

By using the TEMPERATURE SETTING button, set function code and


2 setting value. (Please refer the Installer Setting Code Table.)

Function Code

Setting Code

Press the ON/OFF button toward the indoor unit 1 time.


3

Group Control Setting


Dip Switch &
Reset the remote controller to use the general operation mode.
4

Dip Switch & Group Control Setting _ 7


2. Wall Mounted, ART COOL Gallery, ART COOL Mirror
Installer Setting Code Table

No. Function Function Code Setting Value Remote Controller LCD


0 : Set to Master 00
0 Mode Override 0
1 : Set to Slave 01
1 : Standard 11
Ceiling Height 1 2 : Low 12
1
Selection 3 : High 13
4 : Super High 14
0 : Set to Master 20
Group Control 2 1 : Set to Slave 21
2 : Check Master/Slave 22
2
3 : Set to Auxiliary heater 23
Auxiliary
2 4 : Cancel Auxiliary heater 24
heater
2 : Check Auxiliary heater Installation 25

Group Control Setting


- This function is only for group control.
- Please donʼt set this function in case of non-group control.
- This function is the Master or Slave setting function of indoor unit
- Set only one indoor unit to Master, set the others to slave.
Group Control Setting

- After setting Group Control of the product, turn off the power then turn it back on after 1 minute.
- Master checking whether the buzzer sounds, such as indoor rings below.
Dip Switch &

► Master: “Beep” (Buzzer sound 1 time)


► Slave: “Beep, Beep, Beep, Beep, Beep ” (Buzzer sounds 5 times)

8 _ Dip Switch & Group Control Setting


2. Wall Mounted, ART COOL Gallery, ART COOL Mirror
Group Control Setting
- This function is only for group control.
- Please donʼt set this function in case of non-group control.
- This function is the Master or Slave setting function of indoor unit
- Set only one indoor unit to Master, set the others to slave.
- After setting Group Control of the product, turn off the power then turn it back on after 1 minute.
- Master checking whether the buzzer sounds, such as indoor rings below.
► Master: “Beep” (Buzzer sound 1 time)
► Slave: “Beep, Beep, Beep, Beep, Beep ” (Buzzer sounds 5 times)

2.2 Group Control 1


(1) Group Control 1
n Wired remote controller 1 + Standard Indoor Units

LGAP Network System

Group Control Setting


GND
Master Slave Slave Slave Signal

Dip Switch &


12 V

Display Error Message Only connect serial signal and GND lines
between slave indoor unit

Master

1. It is possible to 16 indoor units(Max) by one wired remote controller.


Set only one indoor unit to Master, set the others to Slave.
2. You can connect all the types of 2nd generation indoor units .
3. It is possible to use wireless remote controller at the same time.

Dip Switch & Group Control Setting _ 9


2. Wall Mounted, ART COOL Gallery, ART COOL Mirror
4. It is possible to connect with Dry Contact and Central controller at the same time.
- The Master indoor unit is possible to recognize Dry Contact and Central Controller only.
- In case of Central controller and Group controller at the same time, it is possible to connect standard 2series indoor
units or later since Feb. 2009.
- In case of Central controller setting, the Central controller can control indoor units after setting only the address of
master indoor unit.
- Slave indoor unit will be operated like master indoor unit.
- Slave indoor unit can not be individually controlled by Central controller.
- Some remote controller canʼt perform with Dry Contact and Central controller at the same time. So contact us further
information about it.

5. In case that the indoor unit has an abnormal problem an error code will be displayed on the wired remote
controller.
With the exception of the indoor unit with the error, you can control each indoor unit individually.

6. In case of Group Control, it is possible to use following functions.


- Selection of operation options (operation/stop/mode/set temperature)
- Control of flow rate (High/Middle/Low)
- It is not possible at some functions.

❈ Indoor units be set possible using a wireless remote controller.


This indoor unit be set possible using a wireless remote controller for setting group control.
(type : Wall Mounted, ART COOL Gallery, ART COOL Mirror)
❈ It is possible to connect indoor units since Feb. 2009.
In the other cases, please contact LGE.
❈ It can be the cause of malfuctions when there is no setting of master and slave.
Group Control Setting
Dip Switch &

10 _ Dip Switch & Group Control Setting


2. Wall Mounted, ART COOL Gallery, ART COOL Mirror
(2) Group Control 2
n Wired remote controllers + Standard Indoor Units

LGAP Network System

GND
Master Slave Slave Slave Signal
12 V

Donʼt connect serial 12V line

Display Error Message

Master Slave

h It is possible to control N indoor units by wired remote controller M units. (M+N≤17 Units)
Set only one indoor unit to Master, set the others to Slave.

Group Control Setting


Set only one wired remote controller to Master, set the others to Slave.
Other than those, it is same with the Group Control 1.

Dip Switch &

Dip Switch & Group Control Setting _ 11


2. Wall Mounted, ART COOL Gallery, ART COOL Mirror
(3) Group Control 3
n Mixture connection with indoor units and Fresh Air Intake Unit

LGAP Network System

GND
FAU FAU Master Slave Signal
Master
Master Slave 12 V

Display Error Message

Master Master

h In the case that you connect standard indoor units and Fresh Air Intake Units together, control them separately from
each other with different wired remote controllers.
h Other than those, it is same with Group Control 1.
Group Control Setting
Dip Switch &

FAU FAU Standard Standard FAU FAU Standard Standard

* FAU : Fresh Air Intake Unit


Standard: Standard Indoor Unit

12 _ Dip Switch & Group Control Setting


2. Wall Mounted, ART COOL Gallery, ART COOL Mirror
2.3 2 Remote Control
n Wired remote controller 2 + Indoor unit 1

LGAP Network System

Master

Display Error Message

Master Slave

1. It is possible to connect two wired remote controllers with one indoor unit.
2. You can connect any of the types of 2nd generation indoor units to two wired remote controllers.

Group Control Setting


3. It is possible to use wireless remote controller at the same time.
4. It is possible to connect with Dry Contact and Central controller at the same time.

Dip Switch &


5. In case that the indoor unit has an abnormal problem an error code will be displayed on the wired remote
controller.
With the exception of the indoor unit with the error, you can control each indoor unit individually.
6. There isn’t limits of indoor unit function.
❈ Maximum 2wired remote controllers can be connected with 1 indoor unit.

Dip Switch & Group Control Setting _ 13


2. Wall Mounted, ART COOL Gallery, ART COOL Mirror
2.4 Accessories for group control setting
It is possible to set group control by using below accessories.

Indoor unit 2 EA +Wired remote controller Indoor unit 1 EA +Wired remote controller 2EA

h PZCWRCG3 cable used for connection h PZCWRC2 cable used for connection

Mas te r S lave

PZC WRC 2

PZC WRC G3

Maste r Maste r S lave


Group Control Setting
Dip Switch &

14 _ Dip Switch & Group Control Setting


P/No.: MFL61741620

Air Conditioner
20 Yeouido-dong, Yeongdeungpo-gu,
Yeouido P.O.Box 335 Seoul,
150-721, Korea.
http://www.lgeaircon.com

All rights reserved


Printed in Korea Ma\ / 2014 The air conditioners manufactured by LG have received ISO9001 certificate for
The specifications, designs, and quality assurance and ISO14001 certificate for environmental management system.
information in this brochure are subject to
change without notice.

You might also like