You are on page 1of 3

Product: TRACK-TYPE TRACTOR

Model: D6R TRACK-TYPE TRACTOR 2YN


Configuration: D6R Track-Type Tractor 2YN00001-UP (MACHINE) POWERED
BY 3306 Engine

Troubleshooting
561N, 572R and 572R Series II Pipelayers and D10R, D11R, D5M, D5N, D6M, D6N, D6R, D6R
Series II, D7R, D7R Series II and D8R Series II Track-Type Tractors Power Train Electronic
Control System
Media Number -SENR8367-17 Publication Date -01/03/2009 Date Updated -13/03/2009

i01786294

MID 113 - CID 0689 - FMI 03


SMCS - 5479-038-ZH

Conditions Which Generate This Code:

Illustration 1 g00630905

Schematic of the Solenoid for the Left Steering Brake

This diagnostic code is recorded when the ECM reads the voltage of the solenoid circuit as above normal
(short to +battery).

Note: Ensure that the diagnostic code for the solenoid is on hold and that the diagnostic code indicator shows
"SERV CODE".

Test Step 1. CHECK THE SIGNAL CIRCUIT FOR A SHORT TO +BATTERY.

A. Turn the key start switch to the OFF position.

1 of 3 8/21/2020, 11:47 AM
B. Disconnect the machine harness from the solenoid.

C. Disconnect the machine harness connectors J1 and J2 from the ECM.

D. At machine harness connector J2, measure the resistance from the solenoid signal contact to all possible
sources of +battery. The possible sources of positive voltage are contacts J1-1, J1-4, J1-6, J1-8, J1-10,
J1-11, J1-12, J1-17, J1-18, J1-40, J2-1, J2-2, J2-7, J2-8, J2-13, J2-19, and J2-37.

Expected Result:

Each resistance should be greater than 5000 ohms.

Results:

OK - Each resistance is greater than 5000 ohms. Proceed to Test Step 2.

NOT OK - Each resistance is not greater than 5000 ohms.

Repair: There is a short in the machine harness. The short is between the contact for the solenoid signal
and the circuit with a low resistance measurement. Repair the machine harness or replace the machine
harness.

Stop.

Test Step 2. DETERMINE IF THE DIAGNOSTIC CODE IS STILL ACTIVE.

A. Inspect the contacts and clean the contacts of the harness connectors.

B. Reconnect all harness connectors.

C. Turn the key start switch to the ON position.

D. Enter service mode of the Caterpillar Monitoring System and clear all inactive diagnostic codes.

E. Operate the machine.

F. Stop the machine and place the parking brake switch in the OFF position.

G. Determine if CID 0689 FMI 03 for the solenoid is present.

Expected Result:

CID 0689 FMI 03 for the solenoid is present. "SERV CODE" is showing.

Results:

YES - CID 0689 FMI 03 for the solenoid is present. "SERV CODE" is showing.

Repair: Exit this procedure and perform the diagnostic code procedure again. If the problem persists,
the ECM may have failed. Prior to replacing an ECM, always contact your dealership's Technical
Communicator for possible consultation with Caterpillar. This consultation may greatly reduce repair
time. See the Testing and Adjusting, "Electronic Control Module (ECM) - Replace".

Stop.

2 of 3 8/21/2020, 11:47 AM
NO - CID 0689 FMI 03 for the solenoid is not present. "SERV CODE" is not showing.

Repair: The problem does not exist at this time. The initial problem was probably caused by a poor
electrical connection or a short at one of the harness connectors that was disconnected and reconnected.
Resume normal machine operation.

Stop.

Copyright 1993 - 2020 Caterpillar Inc. Fri Aug 21 2020 11:47:36 GMT-0700 (Pacific Daylight Time)