Note: This Cert is used for Lay-up Checklists SAIC-A-2018 (Plant Piping & Equipment) & SAIC-L-2124 (Pipelines)
Certificate No. Date:
Equipment: Service Fluid:
System Lay-up Duration: Start - End Date:
Hydro Test Medium: Type of Lay-up:
S.NO METHOD OF LAY-UP Actual Pass Fail Remarks
A Wet Lay-Up
Minimum residual oxygen scavenger concetration in water shall
A1 be 20 ppm & maximum O2 concentration of 10 ppb
Maintain the system under a positive pressure between 30 to 50
A2 psig using nitrogen, sweet hydrocarbon gas or hydraulic
pressure of the treated water
Use gauges to monitor the positive pressure in the system
A3 during lay-up with a scale range not exceeding three times the
target pressure. (Gauges must withstand MAOP)
B Dry Lay-Up
Remove the hydrotest water from the system. For facilities other
B1 than pipelines, drain the system completely, sweep and mop as
required to ensure that no visible traces of water remain.
When the bulk of the water has been removed, blow vapor
Volume of System: _______
E1 phase corrosion inhibitor Cortec VpCI 309 or equivalent with
Amount of VCI Applied: _______
nitrogen until it is visibly discharged at the bottom of the valve.