Professional Documents
Culture Documents
Common Problems and Solutions
Common Problems and Solutions
The tester uses a 4- wire connection method, where A + A- is the current loop (with thick lines)
and V + V- is the voltage measurement (with thin lines).
Check if V + V- is connected.
Check A + A- is connected.
Check whether the termination voltage is set correctly. When the detected voltage is lower than
the termination voltage, the tester will stop or not start.
Whether the use of a matching online cable, the port is selected correctly (in the computer's
Device Manager to view the port to be less than 10 ), the tester is stopped (if you have activated
by the button, the ban on the line).
1.2V NiMH: charging current <= 0.25C , discharge current <= 0.5C , discharge voltage 1.0V .
1.2V NiCr: charging current <= 0.25C , discharge current <= 0.5C , discharge voltage 0.8V .
3.7V lithium: charging current <= 0.5C , charging voltage = 4.2V , discharge current <= 0.5C ,
discharge voltage 2.8V .
3.2V lithium iron: charging current <= 1C , charging voltage = 3.65V , discharge current <= 1C ,
discharge voltage 2.5V .
2V lead-acid: charge current <= 0.25C , charge voltage = 2.4V , discharge current <= 0.5C ,
discharge voltage 1.75V .
The battery test voltage in series is calculated as the number of knots per x section. Current has
nothing to do with the series. Tester measured in series when the capacity of a single capacity.
(C is the discharge rate, the value equal to the capacity, such as 2000mAh battery, 0.5C = 1A ).
The current is generally set by the current of the output that can be supported. The voltage is set
to 4V . After the voltage is discharged less than 4V automatically stop. If you stop after the start,
check whether to set the current is too large, resulting in charging treasure output protection.
Capacity through constant current discharge test, after the test shows . First, the battery is full, and
then set the test current and the corresponding termination voltage discharge, when the discharge
is displayed after the capacity is the current actual capacity.
Tester connected to the computer to support multiple cycles, stand-alone operation generally only
once, specific reference manual .
According to the charging voltage demand, the charging voltage should be set lower than the
power voltage.
A series of test instrument online when the software can test the internal resistance of a single cell,
the specific reference to the software manual.
15. Battery connected to the four-wire test stand can not be normal test
Check whether the copper pin in the center of the battery and the outer metal shell are in good
contact with each other.