You are on page 1of 3

TITLE: : LTE TIMING ADVANCE COUNTERS FAILING TO COLLECT

DATA

INCIDENT DATE: 29/06/2016

TT REFERENCE: EWZINT2016062900001847

PROBLEM DESCRIPTION
In order to measure timing advance in the LTE RAN the feature Enhanced Cell ID and the associated counters
pmRaSuccTa & pmUeCtxtTa on all eNode B’s was activated.

The problem is that when these counters are queried they are not collecting any data as shown below.

The counters are shown below:

1. pmRaSuccTa
2. pmUeCtxtTa

PROBLEM SYMPTOMS

 No Data collected
Econet Wireless Zimbabwe
REMEDY CONDITIONS

We need to use the complete_mom to change the Systemconstants

Note:

1.Before Systemconstants we need activate the feature on the EnodeB.


2. INTERNAL_PER_RADIO_UE_MEASUREMENT_TA this event need to activate on the PMS CTR.

SOLUTION(S)

0043ML> uv use_complete_mom=1

use_complete_mom=1

0043ML> lt all
0043ML> get Systemconstants

160711-09:43:51 10.106.0.101 11.0f ERBS_NODE_MODEL_E_1_63_COMPLETE


stopfile=/tmp/23848
==============================================================================
===================================
1808 NodeManagementFunction=1,SystemConstants=1
==============================================================================
===================================
SystemConstantsId 1
systConstants
==============================================================================
===================================
Total: 1 MOs

0043ML> acl 1808

160630-18:34:29 10.106.xx.xx 10.0s ERBS_NODE_MODEL_E_1_63_COMPLETE


stopfile=/tmp/21049

==============================================================================
===================================
Proxy MO Action Nr of Params
==============================================================================
===================================
1808 SystemConstants=1 resetSystConst 1
1808 SystemConstants=1 writeSystConst 2
Econet Wireless Zimbabwe
==============================================================================
===================================

0043ML> actc 1808 writeSystConst

160630-18:34:39 10.106.xx.xx 10.0s ERBS_NODE_MODEL_E_1_63_COMPLETE


stopfile=/tmp/21049
Call Action writesystconst on following 1 MOs ?
==============================================================================
=====
1808 NodeManagementFunction=1,SystemConstants=1
==============================================================================
=====
Call action writesystconst on 1 MOs. Are you Sure [y/n] ? y

==============================================================================
===================================
Proxy MO Action Nr of Params
==============================================================================
===================================
1808 SystemConstants=1 writeSystConst 2

Parameter 1 of 2, name (string): 503

Parameter 2 of 2, value (string): 1


>>> Return value = null

==============================================================================
===================================
Total: 1 MOs attempted, 1 MOs actioned

0043ML> get 1808

160630-18:35:04 10.106.xx.xx 10.0s ERBS_NODE_MODEL_E_1_63_COMPLETE


stopfile=/tmp/21049
==============================================================================
===================================
1808 NodeManagementFunction=1,SystemConstants=1
==============================================================================
===================================
SystemConstantsId 1
systConstants 503:1
==============================================================================
===================================

CAUSE

Incorrect System Constants configurations.