You are on page 1of 16

PRODUCT

C A T A L O G
HUMIDITY AND TEMPERATURE CALIBRATORS
KAMAL MAHAJAN

CEO
Kamal has been de-
signing humidity and
temperature calibration
products for 15 years.

GEO Calibration
Born in 2010, GEO GEO Calibration is a premiere manufacturer and designer of humidity and temperature calibration products.
has changed the face Originally a rapid prototyping laboratory, GEO products are made from the silicon up. We have full PCB as-
of the Humidity and sembly on site. The products are proudly manufactured in the USA, out of Ronkonkoma, NY. For this reason,
Temperature Calibra- we are able to rapidly innovate within the Humidity and Temperature marketplace, creating solutions
tion market. within months, or sometimes weeks of receiving customer feedback.
Company History
Located in Ronkonkoma, ity generator. GEO (then
NY, GEO Calibration has AMP Design Solutions)
consistently pushed the designed and manufac-
boundries of humid- tured the Model 2000
ity and temperature humidity generator. This
control. was the first unit to use
a high density plastic
THE FIRST UNIT. design, a reverse vortex
Back in 2004, it was chamber insert, and the
difficult to find anyone timed flow / heating
using a single pressure element humidity gen-
humidity calibration eration method.
device. The current lineup of
The industry was awash GEO Calibration humid-
in salt solutions, plexi- ity generators are all
glass “fish-tanks” and improvements on that
two pressure generators. original design, with
At the time, the highest variants for specific
accuracy capacative calibration use cases.
sensor was clocking in As a company, we con-
at around +-2.0% RH tinue to innovate and
accuracy, and there were change the face of the
few good alternatives to Humidity and Tempera-
the chilled mirror as an ture calibration with
accurate reference. each new unit release.
Improvements to
capacative sensors led
to the innovation of the The line assembly of 10 Model 2000 SPs. Marina (pictured above) has been
single pressure humid- with the company for 18 years.

Customer Support
At GEO we strive for the highest quality of customer support and education. We offer a one year warranty
on all of our products (excluding physical damage). Customer’s also have access to direct, GEO technical
support by calling the business phone number.
If a customer happens to have a specialized application that they would like engineered for them, we are
fully equipped and capable to deliver.
2016 in Numbers
+ New Calibrators

10
2016 has been a fantastic year for GEO Calibra-
GEO Calibration offers customers the greatest tion Inc. We saw the introduction of our chamber
choice when it comes to buying a humidity and line-up, and fully injected ourselves into market
temperature calibrator. attending as many NCSLi regional shows as pos-
sible. As we continue to network and learn about
industry demands, we will innovate and develop
our product line so that you the consumer con-
tinue to choose GEO for our versatility.
+
Distributors The NCSLi has been instrumental in our develop-

10
ment as a company, and we are proud to serve on
the steering commity for the Northeast Region. In
We have seen a rapid growth in our sales network. 2016 and beyond, we are directing a significant
Interested? Email sales@GeoCalibration.com amount of internal resources towards education and
training in Humidity and Temperature calibration.
We will open these resources to all NCSLi members.

+ Rapid Growth
Accessories

7
We are beginning to turn our R&D efforts. We are
GEO now offers the largest array of doors and probe currently innovating a number of new product lines
ports, allowing calibration technicians great calibra- for future release within the humidity and tempera-
tion versatility. ture marketplace.

GEO has partnered with Military or rugged field New Live Demo System What Lies Ahead?
Brookhaven National applications?
Laboratory to develop a Contact us today to
humidity and tempera- No problem. schedule a real-time
live demo. No software Geo Calibration is ac-
ture control solution The Model 2000 SHR tively looking into other
for the BNL Particle installation needed.
comes with a hardened Humidity and Tempera-
Accelerator. outer shell, sturdy han- www.geocalibration. ture related markets. As
dles and clamp covers. com/live-demo our calibrators rely on
the current calibration
standards, we are working
on improving the current
standard with our own
unique solution.
Our Units
+ Humidity and Temperature Calibrators
+ Calibration Software
+ Rapid Prototyping
+ Unparalleled Customer Support
+ Modular Design
+ Challenge Standards
+ Customer Education
+ Remote Calibration
GEO Calibration HQ is The Modular design of is calibrating a chart + Scientific R&D
a fully equipped rapid GEO’s humidity calibra- recorder, we have an XL
prototyping and PCB tion chambers allow for door extension that al- + Customization
Assembly facility. versatility in the work lows them to fit the en- + Industry Innovation
environemnt (Calibra- tire chart recorder and
Our Engineering staff tion labs). The four sensor into the chamber
takes direct feedback screws on the front of for verification andc
from the customer, and the unit, along with our alibration purposes.
turns it into real prod- rapid-seal system allow
ucts with unrivaled for the technitian to Similarly, for datalog-
speed. choose the proper door gers we have an expan-
for their workload. sion door that supports
three porous racks on
For instance, if someone which the dataloggers

Modular Design can rest and be exposed


to the controlled
conditions within the
from 6 - 32 mm, and
now, with our slim line
probe ports, you can
chamber. calibrate short probes
as well.
The use of expansion
doors on GEO Calibra- The sample ports on
tion Chambers de- the front of the instru-
pends entirely on your ment allow you to use
accuracy tolerance. If a chilled mirror as an
you have an accuracy external secondary
requirement of +- 2 %, reference. Keep in mind
these units are ideal for that these ports are an
your application. optional extra, and do
not come standard with
We also have quick the purchase of a GEO
release probe ports for Calibration unit.
fast changing. These
are ideal for the field
technitian, as you will
frequently encounter
various probe sizes at
customer locations.
Our versatile line up of
probe port configura-
tions allows you to
calibrate any probe size
The New Hygro Mini
Portable, battery powered humidity & temperature generator / calibrator.

Features:
2 Hour Battery Spill Resistant
3 kg Operates in Various Orientations
± 1.0% RH or better 26.5cm (D) x 27cm (W) x 11cm (H)

CONTROL STANDARD FEATURES


Range RH 10% to 80% @ 23°C Reservoir Capacity20 ml
Temperature 10°C to 40°C Spill Proof
Yes
Dew Point 10°C to 45°C Water Quality Distilled
Uniformity RH ±0.3% @ 10% to 50% Est Refill Period
1 Week *Typical
±0.4% @ 50% to 80% Fill Indicator
On Screen Low Warning
Temperature ±0.2°C @ 50%RH Desiccant Type Molecular Sieve
Stability at RH ± 0.3% @ 23°C External Interface USB Cable and Software Included
Equilibrium Temperature ± 0.2°C MECHANICAL / ELECTRICAL
Controller Type Embedded multi input PID controller, LCD Generator Dimensions 26.5 cm (D) x 27 cm (W) x 11 cm (H)
Resolution RH 0.1% Enclosure Material Powder Coated Aluminum
Temperature 0.1°C Power Supply Universal 100 - 260 VAC - 50/60 Hz
Generation Mixed flow with desiccant dryer cell and Chamber Dimensions 19 cm (D) x 19.5 cm (W) x 7.5 cm (H)
Method Heating element humidifier Capacity 1 rH Probe from 6 - 32 mm
PERFORMANCE Material Insulated Plastic
Response Time RH 7 Minutes Weight 4 kg
Temperature Cooling 1.5°C / Minute Probe Power Supply Power Supply 12 Volt DC @ 1A
Heating 5°C / Minute Probe Ports Port Total 1 Port
Calibration RH ± 1.0% @ 10 - 60% Probe Port Sizes Standard 12.5 mm, 19 mm and 25 mm
Uncertainties ± 1.25% @ 60 - 80% Custom 6 mm to 32 mm
Temperature ± 0.4°C
Control Probe RH Uncertainty ± 0.5% @ 23°C
Calibration Certificate Traceable to NIST
Battery Life Ideal Conditions 5 Hours

CONTACT US:

Sales@GeoCalibration.com 2190 Smithtown Ave,


www.GeoCalibration.com Ronkonkoma NY 11779
(631) 471 - 6157 USA
6
The Model 1500
The original compact humidity generator from GEO.
Lightweight, accurate, efficient.

Features:
Portable Design 8.4 kg
Spill Resistant ± 1.0% RH or better
Custom Probe Ports 37cm (D) x 46cm (W) x 16cm (H)

CONTROL STANDARD FEATURES


Range RH 10% to 95% @ 23°C Water Reservoir
50 ml
Temperature 10 to 55°C Spill ResistantYes
Dew Point - 25°C to 45°C Water Quality Distilled
Uniformity RH ±0.3% @ 10% to 50% Est Refill Period
1 Month *Typical
±0.4% @ 50% to 90% Fill Indicator
Front Panel
±0.5% @ 90% to 95% Desiccant Type Molecular Sieve
Temperature ±0.2°C @ 50%RH External Interface USB Cable and Software Included
Stability at RH ± 0.3% @ 23°C OPTIONAL FEATURES
Equilibrium Temperature ± 0.2°C External Reference Outlet and Inlet Plastic fittings to prevent condensation
Controller Type Embedded multiple input PID controller, LCD Size 1/4" turn quick connectors
Resolution RH 0.1% Analog Outputs Temperature / RH Analog 0 - 1 Volt
Temperature 0.1°C MECHANICAL / ELECTRICAL
Generation Mixed flow with desiccant dryer cell and heating Generator Dimensions 37 cm (D) x 46 cm (W) x 16 cm (H)
Method element humidifier Enclosure Material Powder Coated Aluminum
PERFORMANCE Power Supply Universal 100 - 260 VAC - 50/60 Hz
Response Time RH 3 - 5 Minutes Chamber Dimensions 19 cm (D) x 19.5 cm (W) x 7.5 cm (H)
Temperature Cooling 1.5°C / Minute Volume 1 Liter Effective Working Volume
Heating 5°C / Minute Material Insulated Plastic
Calibration RH ± 1.0% @ 10 - 80% Weight 8.4 kg
Uncertainties ± 1.25% @ 80 - 95% Probe Power Supply Power Supply 12 Volt DC @ 1A
Temperature ± 0.2°C Probe Ports Port Total 3 Ports
Control Probe RH Uncertainty ± 0.5% @ 23°C Probe Port Sizes Standard 12.5 mm, 19 mm and 25 mm
Calibration Certificate Traceable to NIST Custom 6 mm to 32 mm
CONTACT US:

Sales@GeoCalibration.com 2190 Smithtown Ave,


www.GeoCalibration.com Ronkonkoma NY 11779
(631) 471 - 6157 USA
7
The New Model 1000
Compact, light weight humidity generator featuring quick-change desiccant and
improved air flow.
Features:
Quick Change Desiccant 8.4 kg
Spill Resistant ± 1.0% RH or better
Custom Probe Ports 30cm (D) x 46cm (W) x 16cm (H)

CONTROL STANDARD FEATURES


Range RH 5% to 95% @ 23°C Water Reservoir
50 ml
Temperature 10 to 55°C Spill ResistantYes
Dew Point - 25°C to 45°C Water Quality Distilled
Uniformity RH ±0.3% @ 5% to 50% Est Refill Period
1 Month *Typical
±0.4% @ 50% to 90% Fill Indicator
Front Panel
±0.5% @ 90% to 95% Desiccant Type Molecular Sieve
Temperature ±0.2°C @ 50%RH External Interface USB Cable and Software Included
Stability at RH ± 0.3% @ 23°C OPTIONAL FEATURES
Equilibrium Temperature ± 0.2°C External Reference Outlet and Inlet Plastic fittings to prevent condensation
Controller Type Embedded multi input PID controller, LCD Size 1/4" turn quick connectors
Resolution RH 0.1% Analog Outputs Temperature / RH Analog 0 - 1 Volt
Temperature 0.1°C MECHANICAL / ELECTRICAL
Generation Mixed flow with desiccant dryer cell and Generator Dimensions 30 cm (D) x 46 cm (W) x 16 cm (H)
Method Heating element humidifier Enclosure Material Powder Coated Aluminum
PERFORMANCE Power Supply Universal 100 - 260 VAC - 50/60 Hz
Response Time RH 3 - 5 Minutes Chamber Dimensions 19 cm (D) x 19.5 cm (W) x 7.5 cm (H)
Temperature Cooling 1.5°C / Minute Volume 1 Liter Effective Working Volume
Heating 5°C / Minute Material Insulated Plastic
Calibration RH ± 1.0% @ 10 - 80% Weight 8.4 kg
Uncertainties ± 1.25% @ 80 - 95% Probe Power Supply Power Supply 12 Volt DC @ 1A
Temperature ± 0.2°C Probe Ports Port Total 3 Ports
Control Probe RH Uncertainty ± 0.5% @ 23°C Probe Port Sizes Standard 12.5 mm, 19 mm and 25 mm
Calibration Certificate Traceable to NIST Custom 6 mm to 32 mm

CONTACT US:

Sales@GeoCalibration.com 2190 Smithtown Ave,


www.GeoCalibration.com Ronkonkoma NY 11779
(631) 471 - 6157 USA
8
The Model 2000 SP
The 2000 line of humidity generators have the highest capacity, and uniformity of
all our Humidity Generators.
Features:
Chart Recorder Door 2 Liter Chamber Capacity
Quick Release Door Stability Insert
High Capacity Door Best Uniformity

CONTROL STANDARD FEATURES


Range RH 5% to 95% @ 23°C Water Reservoir
150 mL
Temperature 5 to 55°C Spill ResistantYes
Dew Point - 25°C to 45°C Water Quality Distilled
Uniformity RH ±0.2% @ 5% to 50% Est Refill Period
1 Month *Typical
±0.3% @ 50% to 90% Fill Indicator
Front Panel
±0.4% @ 90% to 95% Desiccant Type Molecular Sieve
Temperature ±0.2°C @ 50%RH External Interface USB Cable and Software Included
Stability at RH ± 0.3% @ 23°C OPTIONAL FEATURES
Equilibrium Temperature ± 0.1°C External Reference Outlet and Inlet Plastic fittings to prevent condensation
Controller Type Embedded multiple input PID controller, LCD Size 1/4" turn quick connectors
Resolution RH 0.1% Analog Outputs Temperature / RH Analog 0 - 1 Volt
Temperature 0.1°C MECHANICAL / ELECTRICAL
Generation Mixed flow with desiccant dryer cell and heating Generator Dimensions 37 cm (D) x 46 cm (W) x 23 cm (H)
Method element humidifier Enclosure Material Powder Coated Aluminum
PERFORMANCE Power Supply Universal 100 - 260 VAC - 50/60 Hz
Response Time RH 3 - 5 Minutes Chamber Dimensions 19 cm (Depth) x 14.5 cm (Diameter)
Temperature Cooling 1.5°C / Minute Volume 2 Liter Effective Working Volume
Heating 5°C / Minute Material Insulated Plastic
Calibration RH ± 1.0% @ 10 - 80% Weight 14 kg
Uncertainties ± 1.25% @ 80 - 95% Probe Power Supply Power Supply 12 Volt DC @ 1A
Temperature ± 0.2°C Probe Ports Port Total 4 Ports
Control Probe RH Uncertainty ± 0.5% @ 23°C Probe Port Sizes Standard 12.5 mm, 19 mm and 25 mm
Calibration Certificate Traceable to NIST Custom 6 mm to 32 mm

CONTACT US:

Sales@GeoCalibration.com 2190 Smithtown Ave,


www.GeoCalibration.com Ronkonkoma NY 11779
(631) 471 - 6157 USA
9
The Model 2000 DFB
Purpose built for rapid probe calibration, the 2000 DFB features a patented
method of reading, recording and plotting analog probe data output.
Features:
Analog Probe Reader DFB Software Integration
Automatic Ramp / Soak Technician Profiles
Live Probe Feedback Digital Log Output

CONTROL STANDARD FEATURES


Range RH 5% to 95% @ 23°C Water Reservoir
150 mL
Temperature 5 to 55°C Spill ResistantYes
Dew Point - 25°C to 45°C Water Quality Distilled
Uniformity RH ±0.2% @ 5% to 50% Est Refill Period
1 Month *Typical
±0.3% @ 50% to 90% Fill Indicator
Front Panel
±0.4% @ 90% to 95% Desiccant Type Molecular Sieve
Temperature ±0.2°C @ 50%RH External Interface USB Cable and Software Included
Stability at RH ± 0.3% @ 23°C Digital Feedback Digitally record live analog probe data with internal
Equilibrium Temperature ± 0.1°C (DFB) reference, for automatic calibrations.
Controller Type Embedded multiple input PID controller, LCD OPTIONAL FEATURES
Resolution RH 0.1% External Reference Outlet and Inlet Plastic fittings to prevent condensation
Temperature 0.1°C Size 1/4" turn quick connectors
Generation Mixed flow with desiccant dryer cell and heating Analog Outputs Temperature / RH Analog 0 - 1 Volt
Method element humidifier MECHANICAL / ELECTRICAL
PERFORMANCE Generator Dimensions 37 cm (D) x 46 cm (W) x 23 cm (H)
Response Time RH 3 - 5 Minutes Enclosure Material Powder Coated Aluminum
Temperature Cooling 1.5°C / Minute Power Supply Universal 100 - 260 VAC - 50/60 Hz
Heating 5°C / Minute Chamber Dimensions 19 cm (Depth) x 14.5 cm (Diameter)
Calibration RH ± 1.0% @ 10 - 80% Volume 2 Liter Effective Working Volume
Uncertainties ± 1.25% @ 80 - 95% Material Insulated Plastic
Temperature ± 0.2°C Weight 14 kg
Control Probe RH Uncertainty ± 0.5% @ 23°C Probe Power Supply Power Supply 12 Volt DC @ 1A
Calibration Certificate Traceable to NIST Probe Ports Port Total 4 Ports
Probe Port Sizes Standard 12.5 mm, 19 mm and 25 mm
Custom 6 mm to 32 mm
CONTACT US:

Sales@GeoCalibration.com 2190 Smithtown Ave,


www.GeoCalibration.com Ronkonkoma NY 11779
(631) 471 - 6157 USA
10
The Model 2015 TS
The Model 2015 TS Humidity Generator has a touch screen display, and comes
with our Automatic Calibration Software included.
Features
7 Inch Touch Display Graphing Software
3 Port USB Interface Automatic Ramp / Soak
Unique Technician Profiles Remote Login Capability

CONTROL STANDARD FEATURES


Range RH 5% to 95% @ 23°C Water Reservoir
150 mL
Temperature 5 to 55°C Spill ResistantYes
Dew Point - 25°C to 45°C Water Quality Distilled
Uniformity RH ±0.2% @ 5% to 50% Est Refill Period
1 Month *Typical
±0.3% @ 50% to 90% Fill Indicator
Front Panel
±0.4% @ 90% to 95% Desiccant Type Molecular Sieve
Temperature ±0.2°C @ 50%RH Touch Screen 7 inch Software Included
Stability at RH ± 0.3% @ 23°C USB Ports 3 Female Ports Allows for Keyboard and Mouse
Equilibrium Temperature ± 0.1°C OPTIONAL FEATURES
Controller Type Embedded multiple input PID controller, LCD External Reference Outlet and Inlet Plastic fittings to prevent condensation
Resolution RH 0.1% Size 1/4" turn quick connectors
Temperature 0.1°C Analog Outputs Temperature / RH Analog 0 - 1 Volt
Generation Mixed flow with desiccant dryer cell and heating MECHANICAL / ELECTRICAL
Method element humidifier Generator Dimensions 37 cm (D) x 46 cm (W) x 23 cm (H)
PERFORMANCE Enclosure Material Powder Coated Aluminum
Response Time RH 3 - 5 Minutes Power Supply Universal 100 - 260 VAC - 50/60 Hz
Temperature Cooling 1.5°C / Minute Chamber Dimensions 19 cm (Depth) x 14.5 cm (Diameter)
Heating 5°C / Minute Volume 2 Liter Effective Working Volume
Calibration RH ± 1.0% @ 10 - 80% Material Insulated Plastic
Uncertainties ± 1.25% @ 80 - 95% Weight 14 kg
Temperature ± 0.2°C Probe Power Supply Power Supply 12 Volt DC @ 1A
Control Probe RH Uncertainty ± 0.5% @ 23°C Probe Ports Port Total 4 Ports
Calibration Certificate Traceable to NIST Probe Port Sizes Standard 12.5 mm, 19 mm and 25 mm
Custom 6 mm to 32 mm
CONTACT US:

Sales@GeoCalibration.com 2190 Smithtown Ave,


www.GeoCalibration.com Ronkonkoma NY 11779
(631) 471 - 6157 USA
11
The Model 2000 SH
The Model 2015 TS Humidity Generator has a touch screen display, and comes
with our Automatic Calibration Software included.
Features
7 Inch Touch Display Graphing Software
3 Port USB Interface Automatic Ramp / Soak
Unique Technician Profiles Remote Login Capability

CONTROL STANDARD FEATURES


Range RH 5% to 95% @ 23°C Water Reservoir
150 mL
Temperature 5 to 55°C Spill ResistantYes
Dew Point - 25°C to 45°C Water Quality Distilled
Uniformity RH ±0.2% @ 5% to 50% Est Refill Period
1 Month *Typical
±0.3% @ 50% to 90% Fill Indicator
Front Panel
±0.4% @ 90% to 95% Desiccant Type Molecular Sieve
Temperature ±0.2°C @ 50%RH Touch Screen 7 inch Software Included
Stability at RH ± 0.3% @ 23°C USB Ports 3 Female Ports Allows for Keyboard and Mouse
Equilibrium Temperature ± 0.1°C OPTIONAL FEATURES
Controller Type Embedded multiple input PID controller, LCD External Reference Outlet and Inlet Plastic fittings to prevent condensation
Resolution RH 0.1% Size 1/4" turn quick connectors
Temperature 0.1°C Analog Outputs Temperature / RH Analog 0 - 1 Volt
Generation Mixed flow with desiccant dryer cell and heating MECHANICAL / ELECTRICAL
Method element humidifier Generator Dimensions 37 cm (D) x 46 cm (W) x 23 cm (H)
PERFORMANCE Enclosure Material Powder Coated Aluminum
Response Time RH 3 - 5 Minutes Power Supply Universal 100 - 260 VAC - 50/60 Hz
Temperature Cooling 1.5°C / Minute Chamber Dimensions 19 cm (Depth) x 14.5 cm (Diameter)
Heating 5°C / Minute Volume 2 Liter Effective Working Volume
Calibration RH ± 1.0% @ 10 - 80% Material Insulated Plastic
Uncertainties ± 1.25% @ 80 - 95% Weight 14 kg
Temperature ± 0.2°C Probe Power Supply Power Supply 12 Volt DC @ 1A
Control Probe RH Uncertainty ± 0.5% @ 23°C Probe Ports Port Total 4 Ports
Calibration Certificate Traceable to NIST Probe Port Sizes Standard 12.5 mm, 19 mm and 25 mm
Custom 6 mm to 32 mm
CONTACT US:

Sales@GeoCalibration.com 2190 Smithtown Ave,


www.GeoCalibration.com Ronkonkoma NY 11779
(631) 471 - 6157 USA
12
The Model 2000 SHR
The Model 2015 TS Humidity Generator has a touch screen display, and comes
with our Automatic Calibration Software included.
Features
Ruggedized Outer Shell Front and Rear Clamp Covers
Front Mounted Desiccant Automatic Ramp / Soak
Backlit Fill Indicator High Strength Handles

CONTROL STANDARD FEATURES


Range RH 5% to 95% @ 23°C Water Reservoir
150 mL
Temperature 5 to 55°C Spill ResistantYes
Dew Point - 25°C to 45°C Water Quality Distilled
Uniformity RH ±0.2% @ 5% to 50% Est Refill Period
1 Month *Typical
±0.3% @ 50% to 90% Fill Indicator
Front Panel
±0.4% @ 90% to 95% Desiccant Type Molecular Sieve
Temperature ±0.2°C @ 50%RH Touch Screen 7 inch Software Included
Stability at RH ± 0.3% @ 23°C USB Ports 3 Female Ports Allows for Keyboard and Mouse
Equilibrium Temperature ± 0.1°C OPTIONAL FEATURES
Controller Type Embedded multiple input PID controller, LCD External Reference Outlet and Inlet Plastic fittings to prevent condensation
Resolution RH 0.1% Size 1/4" turn quick connectors
Temperature 0.1°C Analog Outputs Temperature / RH Analog 0 - 1 Volt
Generation Mixed flow with desiccant dryer cell and heating MECHANICAL / ELECTRICAL
Method element humidifier Generator Dimensions 37 cm (D) x 46 cm (W) x 23 cm (H)
PERFORMANCE Enclosure Material Powder Coated Aluminum
Response Time RH 3 - 5 Minutes Power Supply Universal 100 - 260 VAC - 50/60 Hz
Temperature Cooling 1.5°C / Minute Chamber Dimensions 19 cm (Depth) x 14.5 cm (Diameter)
Heating 5°C / Minute Volume 2 Liter Effective Working Volume
Calibration RH ± 1.0% @ 10 - 80% Material Insulated Plastic
Uncertainties ± 1.25% @ 80 - 95% Weight 14 kg
Temperature ± 0.2°C Probe Power Supply Power Supply 12 Volt DC @ 1A
Control Probe RH Uncertainty ± 0.5% @ 23°C Probe Ports Port Total 4 Ports
Calibration Certificate Traceable to NIST Probe Port Sizes Standard 12.5 mm, 19 mm and 25 mm
Custom 6 mm to 32 mm
CONTACT US:

Sales@GeoCalibration.com 2190 Smithtown Ave,


www.GeoCalibration.com Ronkonkoma NY 11779
(631) 471 - 6157 USA
13
The New Model 4000

Features:
Analog Probe Reader DFB Software Integration
Automatic Ramp / Soak Technician Profiles
Live Probe Feedback Digital Log Output

CONTROL STANDARD FEATURES


Range RH 5% to 95% @ 23°C Water Reservoir
150 mL
Temperature 5 to 55°C Spill ResistantYes
Dew Point - 25°C to 45°C Water Quality Distilled
Uniformity RH ±0.2% @ 5% to 50% Est Refill Period
1 Month *Typical
±0.3% @ 50% to 90% Fill Indicator
Front Panel
±0.4% @ 90% to 95% Desiccant Type Molecular Sieve
Temperature ±0.2°C @ 50%RH External Interface USB Cable and Software Included
Stability at RH ± 0.2% @ 23°C Digital Feedback Digitally record live analog probe data with internal
Equilibrium Temperature ± 0.1°C (DFB) reference, for automatic calibrations.
Controller Type Embedded multiple input PID controller, LCD OPTIONAL FEATURES
Resolution RH 0.1% External Reference Outlet and Inlet Plastic fittings to prevent condensation
Temperature 0.1°C Size 1/4" turn quick connectors
Generation Mixed flow with desiccant dryer cell and heating Analog Outputs Temperature / RH Analog 0 - 1 Volt
Method element humidifier MECHANICAL / ELECTRICAL
PERFORMANCE Generator Dimensions 37 cm (D) x 46 cm (W) x 23 cm (H)
Response Time RH 3 - 5 Minutes Enclosure Material Powder Coated Aluminum
Temperature Cooling 1.5°C / Minute Power Supply Universal 100 - 260 VAC - 50/60 Hz
Heating 5°C / Minute Chamber Dimensions 19 cm (Depth) x 14.5 cm (Diameter)
Calibration RH ± 1.0% @10 - 80% Volume 2 Liter Effective Working Volume
Uncertainties ± 1.25% @ 80 - 95% Material Insulated Plastic
Temperature ± 0.2°C Weight 14 kg
Control Probe RH Uncertainty ± 0.5% @ 23°C Probe Power Supply Power Supply 12 Volt DC @ 1A
Calibration Certificate Traceable to NIST Probe Ports Port Total 4 Ports
Probe Port Sizes Standard 12.5 mm, 19 mm and 25 mm
Custom 6 mm to 32 mm
CONTACT US:

Sales@GeoCalibration.com 2190 Smithtown Ave,


www.GeoCalibration.com Ronkonkoma NY 11779
(631) 471 - 6157 USA
14
Remote Monitoring
System

Glove Box

Model 4000 Model 2000 SHR

Hygro Mini Model 2000 SH

Model 1000

Model 2000 DFB

Model 1500

Model 2000 SP

Model 2000
TA R G E T
INDUSTRIES
PHARMACEUTICAL
MANUFACTURING

CALIBRATION LABS

BIOMEDICAL

R&D
FACILITIES

AGRICULTURAL

AUTOMOTIVE
MANUFACTURING

AEROSPACE

HOSPITAL / MEDICAL

CONTACT US: Sales@GeoCalibration.com 2190 Smithtown Ave,


www.GeoCalibration.com Ronkonkoma NY 11779
(631) 471 - 6157 USA

© 2015 GEO Calibration Inc. All rights reserved.

You might also like