You are on page 1of 2

Diagnosis Assistance System Copyright 1999 Daimler AG

VIN Mo d e l s e rie s /mo d e l ACTROS 930.0 - 934.3


d e s ig n atio n

Ord e r n u mb e r Lice n s e p late

Current fault codes

Control unit: ZDS

Code Text Status


1E101 Parameter checksum fault CURRENT

1E102 Control unit unlocking list faulty CURRENT

1E203 The latest data transfer has not been completed. CURRENT

1E204 One of the control units is not responding. CURRENT

1E205 One of the control units denies the unlocking command. CURRENT

1E206 One of the control units recognizes the message 'No safe condition'. CURRENT

1E207 Parameters could not be written to one of the control units. CURRENT

1E208 Parameters could not be read from one of the control units. CURRENT

1E309 The last interlock cancel date of one control unit does not match the corresponding CURRENT
date stored in control unit ZDS Central data memory.

1E30A The ID block of one of the control units is incorrect. CURRENT

1E30B The VIN of one of the control units is different from the VIN of control unit GM Base CURRENT
module.

1E30C The data of the central data memory stored in the mirror memory of control unit CURRENT
INS Instrument are not up-to-date.

1E30D The data of control unit GM Base module stored in the mirror memory of control CURRENT
unit INS Instrument are not up-to-date.

1E30E There is no information stored in the central data memory for one of the control CURRENT
units installed.

1E30F There is no information stored in the central data memory for one of the control CURRENT
units installed.

1E310 The memory area of one control unit has a checksum error. CURRENT

1E401 The central data memory data could not be written to the mirror memory. CURRENT

1E402 Unable to read data from mirror memory. CURRENT

1E403 No backup copy of data of control unit ZDS Central data memory found in mirror CURRENT
memory of control unit INS Instrument.

1E404 The data of the external control units in the mirror memory are not up to date. CURRENT

1E405 The data stored in the central data memory and their backup copy stored in the CURRENT
mirror memory of control unit INS Instrument are incompatible with one another.

1E411 The data of control unit GM Base module could not be written to the mirror CURRENT
memory.

1E412 The data of control unit GM Base module could not be read from the mirror CURRENT
memory.

1E413 No backup copy of data of control unit GM Base module found in mirror memory of CURRENT
control unit INS Instrument.

1E414 The data of the virtual control units in the mirror memory are not up to date. CURRENT

1E415 The data stored in control unit GM Base module are incompatible with the data CURRENT
stored in the mirror memory of control unit INS Instrument.

1E504 Plant mode active CURRENT

1E505 Memory in central data memory is full. CURRENT

1E416 No memory area for base module or central data memory in mirror memory CURRENT

Friday, March 23, 2012 18:53:21 Page 1/2


53);(1756);(1757);(1758);(1759);(1760);(1761);(1763);(1764);(1766);(1767);(1769);(1770);(1775);(1777);(1778);(1779);(1780);(1781);(1782);(1783);(1787);(1792);(1796);(1798);(1821);(1801);(1802);(1804);(
Diagnosis Assistance System Copyright 1999 Daimler AG

1E417 The data for the base module and (or) its virtual control units are not compatible CURRENT
with the data stored in the mirror memory.

File n ame : F:\Programme\Das\trees\Lkw\Zds\ZdsMp201\sgscreen\AfZdsMp2.s

Ce ll co-o rd in ate : 9 , 10

Friday, March 23, 2012 18:53:21 Page 2/2