Professional Documents
Culture Documents
TYPICAL PUMP
PERFORMANCE CURVES
3/2 NP P AH ISSUED
GLAND SEALED PUMP JAN 1997
Frame C CC NP P Normal Max. Metal 3100
MIN. PASSAGE SIZE
Rating [kW] 30 55 38 75 [r/min] Polymer 2495 19
mm SPHERE
CURVE SHOWS APPROXIMATE PERFORMANCE FOR CLEAR WATER. (To International Test Standard ISO2548 Class C) : For
media other than water, corrections must be made for density, viscosity and/or other effects of solids. WARMAN INTERNATIONAL
LTD. reserve the right to change pump performance and/or delete impellers without notice. Frame suitability must be checked for COPYRIGHT © 1998-2004
each duty and drive arrangement. Not all frame alternatives are necessarily available from each manufacturing centre. WARMAN INTERNATIONAL LTD.
H
(m) MATCHING VOLUTE LINER C2110HET1
40%
3100
50%
60%
r/min
80 65%
REVISION:NEW TESTED PERFORMANCE
70%
73%
LAST ISSUE:ESY8509 / JULY 1996
2900
%
74.5
70
2700
%
73
60
2500
8m
50
6m
2300
A1-131718/2
4m
NPSH
3m
2m
40 2100
REF:TEST: 154, 154A - 154D; A4-P-2642 DEC/96
1900
30
Y
1700
EFFIC
20 1500
1300
1100
10
0
0 50 100 150
Q (m³/h)