Cartridge Valves Technical Information


Spreader valves
Quick reference

Symbol Model No. Cavity Description Flow* Pressure Page


2FFL12 none Spreader valve package 114 l/min 138 bar 15.5
[30 US gal/min] [2000 psi]

A
P
S

T
P102 862E

Symbol Model No. Cavity Description Flow* Pressure Page


2FL12 none Spreader valve package 114 l/min 138 bar 15.6
[30 US gal/min] [2000 psi]

P T

P102 863

Symbol Model No. Cavity Description Flow* Pressure Page


2FLW86 none Spreader valve package 114 l/min 138 bar 15.7
[30 US gal/min] [2000 psi]

P T
Spreader valves
Quick reference

A
P102 867

* Flow ratings are based on a pressure drop of 7 bar [100 psi] unless otherwise noted. They are for comparison
purposes only.

BLN-10201 • 520L0588 • Rev B • April 2005 15.1


Introduction Quick reference Index

Cartridge Valves Technical Information


Spreader valves
Quick reference

Symbol Model No. Cavity Description Flow* Pressure Page


2FF12 none Spreader valve package 114 l/min 138 bar 15.8
[30 US gal/min] [2000 psi]

A
P
S

T
P102 870

Symbol Model No. Cavity Description Flow* Pressure Page


2FFC12 none Spreader valve package 57 l/min 207 bar 15.9
A [15 US gal/min] [3000 psi]

P L

P102 876

Symbol Model No. Cavity Description Flow* Pressure Page


2FFLC12 none Spreader valve package 114 l/min 207 bar 15.10
A
[30 US gal/min] [3000 psi]

T
P L

P102 884
Spreader valves
Quick reference

* Flow ratings are based on a pressure drop of 7 bar [100 psi] unless otherwise noted. They are for comparison
purposes only.

15.2 BLN-10201 • 520L0588 • Rev B • April 2005


Introduction Quick reference Index

Cartridge Valves Technical Information


Spreader valves
Quick reference

Symbol Model No. Cavity Description Flow* Pressure Page


2FFLW86 none Spreader valve package 114 l/min 138 bar 15.11
[30 US gal/min] [2000 psi]

P A
S

T
P102 887

Symbol Model No. Cavity Description Flow* Pressure Page


2FFCW12 none Spreader valve package 114 l/min 138 bar 15.12
A
[30 US gal/min] [2000 psi]

P L

T
P102 889

Spreader valves
Quick reference

* Flow ratings are based on a pressure drop of 7 bar [100 psi] unless otherwise noted. They are for comparison
purposes only.

BLN-10201 • 520L0588 • Rev B • April 2005 15.3


Introduction Quick reference Index

Cartridge Valves Technical Information


Spreader valves
Application notes

FEATURES Sauer-Danfoss has provided the spreader valve market with a wide variety of options.
The primary uses are ice and snow control for many city, county, township, and state,
sand/salt spreader vehicles. Valves have also been applied on many agricultural fertilizer
spreader systems, as well as construction paving equipment. Sauer-Danfoss spreader
valves offer the following features:
Spreader valves
• Manual or remote electrical control
• Load sensing capability
• Single or dual control
• Pressure compensation
• Gasket-mounted configurations
• Adjustable and detented hand
knob with minimum and maximum
stops and 11 positive, easy-to-adjust
positions

F102 015
Spreader valves
Application notes

15.4 BLN-10201 • 520L0588 • Rev B • April 2005


Introduction Quick reference Index

Cartridge Valves Technical Information


Spreader valves
2FFL12

OPERATION The valve maintains constant regulated flow to two actuators even with changes in load
pressure or input flow. The pressure-compensated regulating section bypasses excess
pump flow to tank. The pump operates at the highest load pressure plus control section
pressure drop. The tank or bypass port must be referenced directly to tank and not to
a working line. The direct-acting relief valve senses system pressure and protects the
pump from shock or overload pressure surges. The built-in lever-operated two-way valve
unloads system flow to tank. In the unload condition, a 8.6 bar [125 psi] check valve may
be required in either the A port, the S port or both ports to reduce motor movement
potential, allowing on/unload control of both regulated flows without changing either
flow setting.

SPECIFICATIONS Dimensions mm [in] Schematic

104.6
[4.12]
Approx.
Unload
63.5
A
[2.50] P
S
On

1L10 Relief cartridge


121.2 7.1
[4.77] [0.28]

T 131.8
[5.19]
Approx.
P 95.8
80.3 [3.77]
[3.16] S 101.6 T
A 42.9
[4.00] P102 862E
[1.69]

Theoretical performance
5.8 32.3 16.0 gpm L/min 154 SUS (33 cSt) hyd. oil @ 100° F (38° C)
[0.23] [1.27] [0.63] 16 60
63.5
A
[2.50]
88.9 13 50
127.0 [3.50]
[5.00]
11 40
P102 885E
Flow

8 30
S
Specifications 5 20
Rated pressure 138 bar [2000 psi]
Rated flow at 7 bar 114 l/min [30 US gal/min] 3 10

[100 psi] 0
Weight 3.08 kg [6.79 lb] 1 2 3 4 5 6 7 8 9 10 11
Hand knob detent positions
P102 874E

ORDERING 2FFL12 - D 6 - 5/15 SV


Spreader valves

Seals
INFORMATION Service parts SV = Viton
Knob kit = 158B8962
2FFL12

Regulated flow range


Seal kit (knob) = 158B8858 Port size S (spinner)
Seal kit (1L10) = 158G1144 6 = 3/4 in NPTF (APT), 1/2 in NPTF (S) 5 = 0-19 L/min [0-5 gpm]
Lever kit = 158B8972 G = Gasket, consult factory 7 = 0-26 L/min [0-7 gpm]
10 = 0-38 L/min [0-10 gpm]
Adjustment options A (auger)
D = Detented hand knob 15 = 0-57 L/min [0-15 gpm]
30 = 0-114 L/min [0-30 gpm]
P102 880E

BLN-10201 • 520L0588 • Rev B • April 2005 15.5


Introduction Quick reference Index

Cartridge Valves Technical Information


Spreader valves
2FL12

OPERATION The valve maintains constant regulated flow even with changes in load pressure or input
flow. The pressure-compensated regulating section bypasses excess pump flow to tank.
The tank or bypass port must be referenced directly to tank and not to a working line.
The direct acting relief valve senses system pressure and protects the pump from shock
or overload pressure surges. The built-in, lever-operated, two-way valve unloads system
flow to tank. This allows on-unload control of regulated flow without changing the flow
setting. In the unload condition a 4.5 bar [65 psi] check valve may be required in the
regulated port to reduce the potential of motor movement.

SPECIFICATIONS Dimensions mm [in] Schematic


206.2
[8.12] 1L10
108.0 Cartridge
[4.25]

104.6
[4.12]
Approx. P T
Unload 63.5
[2.50]

On
165.1 A
[6.50]
7.1 Ø
121.2
[0.28]
[4.77]

T 131.8
[5.19] P102 863
Approx.
80.3 95.8
[3.16] P [3.77]
5.8 101.6
[0.23] A [4.00]
Theoretical performance
gpm L/min 154 SUS (33 cSt) hyd. oil @ 100° F (38° C)
42.9
5.8 32 120
[1.69]
[0.23] 15.7 j.
[0.62] ad
63.5 26 100 g pm
[2.50] 30
0– .
dj
ma
88.9
[3.50] 21 80 0 gp
127.0 0–2
[5.00]
Flow

P102 864E 16 60

Specifications ad j.
gpm
11 40 0–10
Rated pressure 138 bar [2000 psi]
0–5 gpm adj.
Rated flow at 7 bar 114 l/min [30 US gal/min] 5 20

[100 psi] 0
Weight 2.90 kg [6.39 lb] A 1 2 3 4 5 6 7 8 9 10 11
Hand knob detent positions
P102 865E

ORDERING 2FL12 - D 6 - 20 SV
Spreader valves

INFORMATION Seals
Regulated flow range SV = Viton
Service parts
2FL12

10 = 0-38 L/min [0-10 gpm]


Knob kit = 158B8962 Port size 15 = 0-57 L/min [0-15 gpm]
Seal kit (knob) = 158B8858 6 = 3/4 in NPTF 20 = 0-76 L/min [0-20 gpm]
Seal kit (1L10) = 158G1144 30 = 0-114 L/min [0-30 gpm]
Lever kit = 158B8972 Adjustment options
D = Detented hand knob
P102 866E

15.6 BLN-10201 • 520L0588 • Rev B • April 2005


Introduction Quick reference Index

Cartridge Valves Technical Information


Spreader valves
2FLW86

OPERATION The valve maintains constant regulated flow even with changes in load pressure or
input flow. The pressure-compensated regulating section bypasses excess pump flow to
tank. The pump operates at load pressure plus control section pressure drop. The tank
or bypass port must be referenced directly to tank and not to a working line. The direct
acting relief valve senses system pressure and protects the pump from shock or over-
load pressure surges. The built -in, solenoid-operated, two-way valve unloads system flow
to tank. In the unload condition, a 8.6 bar [125 psi] check valve may be required in the
regulated port, T port or both to reduce the potential of motor movement. This allows
on-unload control of regulated flow without changing the flow setting.

SPECIFICATIONS Dimensions mm [in] Schematic

104.6
[4.12]
Approx. P T
63.5
[2.50]

233.4 1L10
[9.19] Cartridge
Solenoid Approx.
5.8 115.1
cartridge
[0.23] [4.53]
A
P102 867
T
101.6
[4.00] 109.5
89.7 P
[4.31]
[3.53] A Approx.

5.8 80.3 42.9


[1.69]
Theoretical performance
[0.23] [3.16] gpm L/min 154 SUS (33 cSt) hyd. oil @ 100° F (38° C)
15.7
63.5 [0.62] 32 120
7.1 Ø [2.50] j.
[0.28] 88.9 ad
26 100 g pm
[3.50] 30
0– .
127.0 dj
[5.00] ma
21 80 0 gp
P102 868E 0–2
Flow

16 60

Specifications ad j.
gpm
11 40 0–10
Rated pressure 138 bar [2000 psi]
0–5 gpm adj.
Rated flow at 7 bar 114 l/min [30 US gal/min] 5 20

[100 psi] 0
Weight 2.90 kg [6.39 lb] A 1 2 3 4 5 6 7 8 9 10 11
Hand knob detent positions
P102 865E

2FLW86 - D 6 - 20 SV
ORDERING
Spreader valves

INFORMATION Seals
Service parts Regulated flow range SV = Viton
2FLW86

Knob kit = 158B8962 10 = 0-38 L/min [0-10 gpm]


Seal kit (knob) = 158B8858 Port size 15 = 0-57 L/min [0-15 gpm]
Seal kit (1L10) = 158G1144 6 = 3/4 in NPTF 20 = 0-76 L/min [0-20 gpm]
Solenoid: 30 = 0-114 L/min [0-30 gpm]
P12VDC (12volt) Adjustment options
P24VDC (24volt) D = Detented hand knob
P102 869E

BLN-10201 • 520L0588 • Rev B • April 2005 15.7


Introduction Quick reference Index

Cartridge Valves Technical Information


Spreader valves
2FF12

OPERATION The valve maintains constant regulated flow to two actuators even with changes in load
pressure or input flow. The pressure-compensated regulating section bypasses excess
pump flow to tank. The tank or bypass port must be referenced directly to tank and not
to a working line. A 8.6 bar [125 psi] check valve may be required in either the A port, the
S port or both ports to reduce the potential of motor movement.

SPECIFICATIONS Dimensions mm [in] Schematic

104.6
[4.12]
Approx. A
P
63.5 S
[2.50]

11.2
127.0
[0.44]
149.4 [5.00]
[5.88]
Approx.
7.1 Ø T
121.2 [0.28] P102 870
[4.77]

T
95.8
[3.77]
P 109.5
80.3 [4.31]
[3.16]
S A 42.9 101.6
[1.69] [4.00] Theoretical performance
gpm L/min 154 SUS (33 cSt) hyd. oil @ 100° F (38° C)
584.2 32 120
[23.00]
15.7
38.1 26 100
[0.62]
[1.50] 63.5
[2.50] A
21 80
88.9
[3.50]
Flow

P102 871E 16 60

Specifications 11 40
S
Rated pressure 138 bar [2000 psi]
Rated flow at 7 bar 114 l/min [30 US gal/min] 5 20

[100 psi] 0
Weight 2.86 kg [6.31 lb] 1 2 3 4 5 6 7 8 9 10 11
Hand knob detent positions
P102 872E

ORDERING 2FF12 - D 6 - 5/15 SV


Spreader valves

INFORMATION Seals
Regulated flow range SV = Viton
Service parts
2FF12

S (spinner)
Knob kit = 158B8962 Port size 5 = 0-19 L/min [0-5 gpm]
Seal kit = 158B8858 S = 1/2 in NPTF 10 = 0-38 L/min [0-10 gpm]
6 = 3/4 in NPTF A (auger)
15 = 0-57 L/min [0-15 gpm]
Adjustment options 30 = 0-114 L/min [0-30 gpm]
D = Detented hand knob
P102 873E

15.8 BLN-10201 • 520L0588 • Rev B • April 2005


Introduction Quick reference Index

Cartridge Valves Technical Information


Spreader valves
2FFC12

OPERATION This valve maintains constant regulated flow to two actuators even with changes in load
pressure. The L port senses the load pressure on both actuators and signals the pump to
increase or decrease the supply flow.

SPECIFICATIONS Dimensions mm [in] Schematic


A
104.6
[4.12]
Approx.

63.5
[2.50] P L

117.3
12.7 38.1 [4.62] S
[0.50] [1.50] Approx.

P102 876
L
A
69.3
[2.73]
7.1 Ø 89.7
S
[0.28] [3.53]

108.0
P [4.25]

30.0
5.8
[0.23]
[1.18] Theoretical performance
gpm L/min 154 SUS (33 cSt) hyd. oil @ 100° F (38° C)
63.5
[2.50] 16 60
88.9
[3.50] A
115.1 13 50
[4.53] 127.0
145.0 [5.00]
11 40
[5.71]
Approx.
Flow

P102 877E 8 30
S
Specifications 5 20
Rated pressure 207 bar [3000 psi]
Rated flow at 7 bar 57 l/min [15 US gal/min] 3 10

[100 psi] 0
Weight 2.86 kg [6.31 lb] 1 2 3 4 5 6 7 8 9 10 11
Hand knob detent positions
P102 874E

ORDERING 2FFC12 - D 6 - 5/15 SV


Spreader valves

Seals
INFORMATION Regulated flow range SV = Viton
Service parts
2FFC12

Knob kit = 158B8962 S (spinner)


Port size 5 = 0-19 L/min [0-5 gpm]
Seal kit = 158B8858 6 = 3/4 in NPTF (P & A) 7 = 0-26 L/min [0-7 gpm]
= 1/2 in NPTF (S) 10 = 0-38 L/min [0-10 gpm]
= 1/4 in NPTF (T) A (auger)
Adjustment options 15 = 0-57 L/min [0-15 gpm]
D = Detented hand knob
P102 878E

BLN-10201 • 520L0588 • Rev B • April 2005 15.9


Introduction Quick reference Index

Cartridge Valves Technical Information


Spreader valves
2FFLC12

OPERATION This valve maintains constant regulated flow to two actuators even with changes in load
pressure. The L port senses the load pressure on both actuators to signal the pump to
increase or decrease the supply flow. With the lever in the unload position, no load is
sensed and the pump de-strokes.

SPECIFICATIONS Dimensions mm [in] Schematic


A

150.9 T
[5.94] P L
Approx.

76.2 S
[3.00]
P102 884

152.4
177.8 [6.00]
[7.00]
6.4 Approx.
76.2 12.7
[0.25] [3.00] [0.50]

A L 88.9
[3.50]
19.1 P S 25.4
52.3 [0.75] [1.00]
[2.06]
T Theoretical performance
7.1 Ø gpm L/min 154 SUS (33 cSt) hyd. oil @ 100° F (38° C)
22.1 [0.28] 16 60
[0.87] 49.3
[1.94] 6.4 A
81.0
[0.25] 13 50
[3.19]
111.0
[4.37] 11 40
P102 883E
Flow

8 30
S
Specifications 5 20
Rated pressure 207 bar [3000 psi]
Rated flow at 7 bar 114 l/min [30 US gal/min] 3 10

[100 psi] 0
Weight 3.08 kg [6.79 lb] 1 2 3 4 5 6 7 8 9 10 11
Hand knob detent positions
P102 874E

2FFLC12 - D 6 - 5/15 SV
ORDERING
Spreader valves

Seals
INFORMATION SV = Viton
Service parts
2FFLC12

Knob kit = 158B8962 Regulated flow range


Port size S (spinner)
Seal kit = 158B8858 6 = 3/4 in NPTF = inlet and auger (P & A)
Lever kit = 5 = 0-19 L/min [0-5 gpm]
= 1/2 in NPTF = spinner (A) 7 = 0-26 L/min [0-7 gpm]
Consult factory = 1/4 in NPTF = tank load sense (T & L) 10 = 0-38 L/min [0-10 gpm]
Adjustment options A (auger)
D = Detented hand knob 15 = 0-57 L/min [0-15 gpm]
30 = 0-114 L/min [0-30 gpm]
P102 879E

15.10 BLN-10201 • 520L0588 • Rev B • April 2005


Introduction Quick reference Index

Cartridge Valves Technical Information


Spreader valves
2FFLW86

OPERATION The valve maintains constant regulated flow to two actuators even with changes in load
pressure or input flow. The pressure-compensated regulating section bypasses excess
pump flow to tank. The pump operates at the highest load pressure plus control section
pressure drop. The tank or bypass port must be referenced directly to tank and not to a
working line. The direct acting relief valve senses system pressure and protects the pump
from shock or overload pressure surges. The built-in, solenoid-operated, two-way valve
unloads system flow to tank. In the unload condition a 8.6 bar [125 psi] check valve may
be required in either the A port, the S port or both ports to reduce the potential of motor
movement. This allows on-unload control of both regulated flows without changing
either flow setting.

SPECIFICATIONS Dimensions mm [in] Schematic

1L10 Cartridge
104.6
[4.12]
Approx.
63.5
[2.50] A
P
S
239.8
[9.44]
5.8 Approx. 115.1
11.9 [0.23] [4.53]
[0.47]

T 109.5 T
119.4 [4.31] P102 887
[4.70] 80.3 P Approx.
89.7 [3.16]
[3.53]
S A

42.9
Solenoid 38.1 [1.69] Theoretical performance
cartridge [1.50] gpm L/min 154 SUS (33 cSt) hyd. oil @ 100° F (38° C)
15.7
7.1 Ø 63.5 [0.62] 21 80
[0.28] [2.50]
A
88.9 18 70
[3.50]
127.0 16 60
[5.00]
P102 886E 13 50
S
Flow

11 40

Specifications 8 30

Rated pressure 138 bar [2000 psi] 5 20


Rated flow at 7 bar 114 l/min [30 US gal/min] 3 10
[100 psi] 0
Weight 3.08 kg [6.79 lb] 1 2 3 4 5 6 7 8 9 10 11
Hand knob detent positions
P102 875E

ORDERING 2FFLW86 - D 6 - 5/15 SV


Spreader valves

Seals
INFORMATION SV = Viton
2FFLW86

Service parts Regulated flow range


Port size S (spinner)
Knob kit = 158B8962 6 = 3/4 in NPTF inlet, tank
Seal kit (knob) = 158B8858 5 = 0-19 L/min [0-5 gpm]
and auger (P, T, and A) 7 = 0-26 L/min [0-7 gpm]
Seal kit (1L10) = 158G1144 1/2 in NPTF-spinner (S)
Solenoid: 10 = 0-38 L/min [0-10 gpm]
P12VDC (12volt) Adjustment options A (auger)
P24VDC (24volt) D = Detented hand knob 15 = 0-57 L/min [0-15 gpm]
30 = 0-114 L/min [0-30 gpm]
P102 881E

BLN-10201 • 520L0588 • Rev B • April 2005 15.11


Introduction Quick reference Index

Cartridge Valves Technical Information


Spreader valves
2FFCW12

OPERATION This valve maintains constant regulated flow to two actuators even with changes in load
pressure. The L port senses the load pressure on both actuators to signal the pump to
increase or reduce the supply flow. With the solenoid in the unload position, no load is
sensed and the pump de-strokes. In the unload condition a 4.5 bar [65 psi] check valve
may be required in either the A port, the S port or both ports to reduce the potential of
motor movement.

SPECIFICATIONS Dimensions mm [in] Schematic

161.8 A
Solenoid cartridge 63.5 [6.37]
[2.50] Approx.
Detent
adjust P L
Auger

111.0
[4.37] S
127.0
[5.00]
T
Spinner T P102 889
23.6
106.7 [0.93]
7.1 Ø
[0.28] Detent adjust [4.20]
through 2-places 197.4 Approx.
[7.77]
Approx. 139.7 9.4
[0.37]
[5.50] 108.0
38.1 [4.25]
12.7
[1.50]
[0.50]
38.6
[1.52] 63.5 103.1
A 25.4 [2.50] [4.06] Theoretical performance
[1.00] 84.1 gpm L/min 154 SUS (33 cSt) hyd. oil @ 100° F (38° C)
P L [3.31] 16 60
82.6
[3.25] A
S 13 50
7.9
[0.31] 119.1 11 40
[4.69]
P102 888E
Flow

8 30
S
Specifications 5 20
Rated pressure 138 bar [2000 psi]
Rated flow at 7 bar 114 l/min [30 US gal/min] 3 10

[100 psi] 0
Weight 3.08 kg [6.79 lb] 1 2 3 4 5 6 7 8 9 10 11
Hand knob detent positions
P102 874E

ORDERING 2FFCW12 - D 6 - 5/15 SV


Spreader valves

Seals
INFORMATION Service parts SV = Viton
2FFCW12

Knob kit = 158B8962 Regulated flow range


Seal kit = 158B8858 Port size S (spinner)
Solenoid: 6 = 3/4 in NPTF = inlet and auger (P & A) 5 = 0-19 L/min [0-5 gpm]
P12VDC (12volt) = 1/2 in NPTF = spinner (A) 7 = 0-26 L/min [0-7 gpm]
P24VDC (24volt) = 1/4 in NPTF = tank load sense (T & L) 10 = 0-38 L/min [0-10 gpm]
Adjustment options A (auger)
D = Detented hand knob 15 = 0-57 L/min [0-15 gpm]
30 = 0-114 L/min [0-30 gpm]
P102 882E

15.12 BLN-10201 • 520L0588 • Rev B • April 2005