Professional Documents
Culture Documents
A
P
S
T
P102 862E
P T
P102 863
P T
Spreader valves
Quick reference
A
P102 867
* Flow ratings are based on a pressure drop of 7 bar [100 psi] unless otherwise noted. They are for comparison
purposes only.
A
P
S
T
P102 870
P L
P102 876
T
P L
P102 884
Spreader valves
Quick reference
* Flow ratings are based on a pressure drop of 7 bar [100 psi] unless otherwise noted. They are for comparison
purposes only.
P A
S
T
P102 887
P L
T
P102 889
Spreader valves
Quick reference
* Flow ratings are based on a pressure drop of 7 bar [100 psi] unless otherwise noted. They are for comparison
purposes only.
FEATURES Sauer-Danfoss has provided the spreader valve market with a wide variety of options.
The primary uses are ice and snow control for many city, county, township, and state,
sand/salt spreader vehicles. Valves have also been applied on many agricultural fertilizer
spreader systems, as well as construction paving equipment. Sauer-Danfoss spreader
valves offer the following features:
Spreader valves
• Manual or remote electrical control
• Load sensing capability
• Single or dual control
• Pressure compensation
• Gasket-mounted configurations
• Adjustable and detented hand
knob with minimum and maximum
stops and 11 positive, easy-to-adjust
positions
F102 015
Spreader valves
Application notes
OPERATION The valve maintains constant regulated flow to two actuators even with changes in load
pressure or input flow. The pressure-compensated regulating section bypasses excess
pump flow to tank. The pump operates at the highest load pressure plus control section
pressure drop. The tank or bypass port must be referenced directly to tank and not to
a working line. The direct-acting relief valve senses system pressure and protects the
pump from shock or overload pressure surges. The built-in lever-operated two-way valve
unloads system flow to tank. In the unload condition, a 8.6 bar [125 psi] check valve may
be required in either the A port, the S port or both ports to reduce motor movement
potential, allowing on/unload control of both regulated flows without changing either
flow setting.
104.6
[4.12]
Approx.
Unload
63.5
A
[2.50] P
S
On
T 131.8
[5.19]
Approx.
P 95.8
80.3 [3.77]
[3.16] S 101.6 T
A 42.9
[4.00] P102 862E
[1.69]
Theoretical performance
5.8 32.3 16.0 gpm L/min 154 SUS (33 cSt) hyd. oil @ 100° F (38° C)
[0.23] [1.27] [0.63] 16 60
63.5
A
[2.50]
88.9 13 50
127.0 [3.50]
[5.00]
11 40
P102 885E
Flow
8 30
S
Specifications 5 20
Rated pressure 138 bar [2000 psi]
Rated flow at 7 bar 114 l/min [30 US gal/min] 3 10
[100 psi] 0
Weight 3.08 kg [6.79 lb] 1 2 3 4 5 6 7 8 9 10 11
Hand knob detent positions
P102 874E
Seals
INFORMATION Service parts SV = Viton
Knob kit = 158B8962
2FFL12
OPERATION The valve maintains constant regulated flow even with changes in load pressure or input
flow. The pressure-compensated regulating section bypasses excess pump flow to tank.
The tank or bypass port must be referenced directly to tank and not to a working line.
The direct acting relief valve senses system pressure and protects the pump from shock
or overload pressure surges. The built-in, lever-operated, two-way valve unloads system
flow to tank. This allows on-unload control of regulated flow without changing the flow
setting. In the unload condition a 4.5 bar [65 psi] check valve may be required in the
regulated port to reduce the potential of motor movement.
104.6
[4.12]
Approx. P T
Unload 63.5
[2.50]
On
165.1 A
[6.50]
7.1 Ø
121.2
[0.28]
[4.77]
T 131.8
[5.19] P102 863
Approx.
80.3 95.8
[3.16] P [3.77]
5.8 101.6
[0.23] A [4.00]
Theoretical performance
gpm L/min 154 SUS (33 cSt) hyd. oil @ 100° F (38° C)
42.9
5.8 32 120
[1.69]
[0.23] 15.7 j.
[0.62] ad
63.5 26 100 g pm
[2.50] 30
0– .
dj
ma
88.9
[3.50] 21 80 0 gp
127.0 0–2
[5.00]
Flow
P102 864E 16 60
Specifications ad j.
gpm
11 40 0–10
Rated pressure 138 bar [2000 psi]
0–5 gpm adj.
Rated flow at 7 bar 114 l/min [30 US gal/min] 5 20
[100 psi] 0
Weight 2.90 kg [6.39 lb] A 1 2 3 4 5 6 7 8 9 10 11
Hand knob detent positions
P102 865E
ORDERING 2FL12 - D 6 - 20 SV
Spreader valves
INFORMATION Seals
Regulated flow range SV = Viton
Service parts
2FL12
OPERATION The valve maintains constant regulated flow even with changes in load pressure or
input flow. The pressure-compensated regulating section bypasses excess pump flow to
tank. The pump operates at load pressure plus control section pressure drop. The tank
or bypass port must be referenced directly to tank and not to a working line. The direct
acting relief valve senses system pressure and protects the pump from shock or over-
load pressure surges. The built -in, solenoid-operated, two-way valve unloads system flow
to tank. In the unload condition, a 8.6 bar [125 psi] check valve may be required in the
regulated port, T port or both to reduce the potential of motor movement. This allows
on-unload control of regulated flow without changing the flow setting.
104.6
[4.12]
Approx. P T
63.5
[2.50]
233.4 1L10
[9.19] Cartridge
Solenoid Approx.
5.8 115.1
cartridge
[0.23] [4.53]
A
P102 867
T
101.6
[4.00] 109.5
89.7 P
[4.31]
[3.53] A Approx.
16 60
Specifications ad j.
gpm
11 40 0–10
Rated pressure 138 bar [2000 psi]
0–5 gpm adj.
Rated flow at 7 bar 114 l/min [30 US gal/min] 5 20
[100 psi] 0
Weight 2.90 kg [6.39 lb] A 1 2 3 4 5 6 7 8 9 10 11
Hand knob detent positions
P102 865E
2FLW86 - D 6 - 20 SV
ORDERING
Spreader valves
INFORMATION Seals
Service parts Regulated flow range SV = Viton
2FLW86
OPERATION The valve maintains constant regulated flow to two actuators even with changes in load
pressure or input flow. The pressure-compensated regulating section bypasses excess
pump flow to tank. The tank or bypass port must be referenced directly to tank and not
to a working line. A 8.6 bar [125 psi] check valve may be required in either the A port, the
S port or both ports to reduce the potential of motor movement.
104.6
[4.12]
Approx. A
P
63.5 S
[2.50]
11.2
127.0
[0.44]
149.4 [5.00]
[5.88]
Approx.
7.1 Ø T
121.2 [0.28] P102 870
[4.77]
T
95.8
[3.77]
P 109.5
80.3 [4.31]
[3.16]
S A 42.9 101.6
[1.69] [4.00] Theoretical performance
gpm L/min 154 SUS (33 cSt) hyd. oil @ 100° F (38° C)
584.2 32 120
[23.00]
15.7
38.1 26 100
[0.62]
[1.50] 63.5
[2.50] A
21 80
88.9
[3.50]
Flow
P102 871E 16 60
Specifications 11 40
S
Rated pressure 138 bar [2000 psi]
Rated flow at 7 bar 114 l/min [30 US gal/min] 5 20
[100 psi] 0
Weight 2.86 kg [6.31 lb] 1 2 3 4 5 6 7 8 9 10 11
Hand knob detent positions
P102 872E
INFORMATION Seals
Regulated flow range SV = Viton
Service parts
2FF12
S (spinner)
Knob kit = 158B8962 Port size 5 = 0-19 L/min [0-5 gpm]
Seal kit = 158B8858 S = 1/2 in NPTF 10 = 0-38 L/min [0-10 gpm]
6 = 3/4 in NPTF A (auger)
15 = 0-57 L/min [0-15 gpm]
Adjustment options 30 = 0-114 L/min [0-30 gpm]
D = Detented hand knob
P102 873E
OPERATION This valve maintains constant regulated flow to two actuators even with changes in load
pressure. The L port senses the load pressure on both actuators and signals the pump to
increase or decrease the supply flow.
63.5
[2.50] P L
117.3
12.7 38.1 [4.62] S
[0.50] [1.50] Approx.
P102 876
L
A
69.3
[2.73]
7.1 Ø 89.7
S
[0.28] [3.53]
108.0
P [4.25]
30.0
5.8
[0.23]
[1.18] Theoretical performance
gpm L/min 154 SUS (33 cSt) hyd. oil @ 100° F (38° C)
63.5
[2.50] 16 60
88.9
[3.50] A
115.1 13 50
[4.53] 127.0
145.0 [5.00]
11 40
[5.71]
Approx.
Flow
P102 877E 8 30
S
Specifications 5 20
Rated pressure 207 bar [3000 psi]
Rated flow at 7 bar 57 l/min [15 US gal/min] 3 10
[100 psi] 0
Weight 2.86 kg [6.31 lb] 1 2 3 4 5 6 7 8 9 10 11
Hand knob detent positions
P102 874E
Seals
INFORMATION Regulated flow range SV = Viton
Service parts
2FFC12
OPERATION This valve maintains constant regulated flow to two actuators even with changes in load
pressure. The L port senses the load pressure on both actuators to signal the pump to
increase or decrease the supply flow. With the lever in the unload position, no load is
sensed and the pump de-strokes.
150.9 T
[5.94] P L
Approx.
76.2 S
[3.00]
P102 884
152.4
177.8 [6.00]
[7.00]
6.4 Approx.
76.2 12.7
[0.25] [3.00] [0.50]
A L 88.9
[3.50]
19.1 P S 25.4
52.3 [0.75] [1.00]
[2.06]
T Theoretical performance
7.1 Ø gpm L/min 154 SUS (33 cSt) hyd. oil @ 100° F (38° C)
22.1 [0.28] 16 60
[0.87] 49.3
[1.94] 6.4 A
81.0
[0.25] 13 50
[3.19]
111.0
[4.37] 11 40
P102 883E
Flow
8 30
S
Specifications 5 20
Rated pressure 207 bar [3000 psi]
Rated flow at 7 bar 114 l/min [30 US gal/min] 3 10
[100 psi] 0
Weight 3.08 kg [6.79 lb] 1 2 3 4 5 6 7 8 9 10 11
Hand knob detent positions
P102 874E
2FFLC12 - D 6 - 5/15 SV
ORDERING
Spreader valves
Seals
INFORMATION SV = Viton
Service parts
2FFLC12
OPERATION The valve maintains constant regulated flow to two actuators even with changes in load
pressure or input flow. The pressure-compensated regulating section bypasses excess
pump flow to tank. The pump operates at the highest load pressure plus control section
pressure drop. The tank or bypass port must be referenced directly to tank and not to a
working line. The direct acting relief valve senses system pressure and protects the pump
from shock or overload pressure surges. The built-in, solenoid-operated, two-way valve
unloads system flow to tank. In the unload condition a 8.6 bar [125 psi] check valve may
be required in either the A port, the S port or both ports to reduce the potential of motor
movement. This allows on-unload control of both regulated flows without changing
either flow setting.
1L10 Cartridge
104.6
[4.12]
Approx.
63.5
[2.50] A
P
S
239.8
[9.44]
5.8 Approx. 115.1
11.9 [0.23] [4.53]
[0.47]
T 109.5 T
119.4 [4.31] P102 887
[4.70] 80.3 P Approx.
89.7 [3.16]
[3.53]
S A
42.9
Solenoid 38.1 [1.69] Theoretical performance
cartridge [1.50] gpm L/min 154 SUS (33 cSt) hyd. oil @ 100° F (38° C)
15.7
7.1 Ø 63.5 [0.62] 21 80
[0.28] [2.50]
A
88.9 18 70
[3.50]
127.0 16 60
[5.00]
P102 886E 13 50
S
Flow
11 40
Specifications 8 30
Seals
INFORMATION SV = Viton
2FFLW86
OPERATION This valve maintains constant regulated flow to two actuators even with changes in load
pressure. The L port senses the load pressure on both actuators to signal the pump to
increase or reduce the supply flow. With the solenoid in the unload position, no load is
sensed and the pump de-strokes. In the unload condition a 4.5 bar [65 psi] check valve
may be required in either the A port, the S port or both ports to reduce the potential of
motor movement.
161.8 A
Solenoid cartridge 63.5 [6.37]
[2.50] Approx.
Detent
adjust P L
Auger
111.0
[4.37] S
127.0
[5.00]
T
Spinner T P102 889
23.6
106.7 [0.93]
7.1 Ø
[0.28] Detent adjust [4.20]
through 2-places 197.4 Approx.
[7.77]
Approx. 139.7 9.4
[0.37]
[5.50] 108.0
38.1 [4.25]
12.7
[1.50]
[0.50]
38.6
[1.52] 63.5 103.1
A 25.4 [2.50] [4.06] Theoretical performance
[1.00] 84.1 gpm L/min 154 SUS (33 cSt) hyd. oil @ 100° F (38° C)
P L [3.31] 16 60
82.6
[3.25] A
S 13 50
7.9
[0.31] 119.1 11 40
[4.69]
P102 888E
Flow
8 30
S
Specifications 5 20
Rated pressure 138 bar [2000 psi]
Rated flow at 7 bar 114 l/min [30 US gal/min] 3 10
[100 psi] 0
Weight 3.08 kg [6.79 lb] 1 2 3 4 5 6 7 8 9 10 11
Hand knob detent positions
P102 874E
Seals
INFORMATION Service parts SV = Viton
2FFCW12