Professional Documents
Culture Documents
Index
T B
FD - Fan Drive HICs
Quick Reference
GT P108 311E
T B
GT
P108 319E
OVERVIEW Off-highway mobile machinery OEMs and distributors can choose from six pre-
engineered Hydraulic Integrated Circuits (HICs) designed to provide speed control and
reversing for hydraulic modulating fan drive motors in open circuit hydraulic fan drive
systems. The program includes:
• Variable Pump fan drive circuits • Fixed Pump fan drive circuits
• HIC provides reversing control and over-pressure • HIC provides modulating and reversing control with
protection/anti-cavitation over-pressure protection/anti-cavitation
• Variable pump provides modulation (speed
control)
Features
Features (continued)
Service screen below illustrates an example reversing fan drive software setup
OPERATION
This HIC reverses flow to the fan motor to reverse fan direction. It includes
a DV15-P5-FD open transition spool valve to reduce pressure spikes during
reversals. Internal and external piloting options are available. The HIC trims
the maximum motor torque by absorbing pressure spikes at the work ports.
An anti-cavitation feature allows additional flow to the motor when the
motor over-runs the pump.
APPLICATIONS
This HIC can be used for fan reversal in circuits using a variable pump.
Use this HIC for mobile equipment such as wheel loaders for purging
(de-clogging) coolers and radiators to prevent overheating and increase
cooling system efficiency. A drain port is included for motor case drain.
SPECIFICATIONS SCHEMATICS
RFDE-40-000 & RFDE-80-000
FD - Fan Drive HICs
PERFORMANCE CURVE
ORDERING
INFORMATION
OPERATION
The RFD-120-000 reverses flow to the fan motor to reverse fan direction. It
includes open transition spools in the directional valves to reduce pressure
spikes during reversals. This HIC trims the maximum motor torque by
absorbing pressure spikes at the work ports. An anti-cavitation feature
allows additional flow to the motor when the motor over-runs the pump.
APPLICATIONS
The RFD-120-000 can be used for fan reversal in circuits using a variable
pump. Use this HIC for applications requiring up to 120 LPM (31.6
GPM) including mobile equipment such as wheel loaders for purging
(de-clogging) coolers and radiators to prevent overheating and increase
cooling system efficiency.
SPECIFICATIONS SCHEMATIC
FD - Fan Drive HICs
Up to 120 l/min
Flow
[31.7 US gal/min]
See performance chart
Weight 4.26 kg [9.40 lb]
Valves CP722-5, SV08-24-01, PVLP
Robust Coil R13 16 Watt (IP69K)
Diode (Optional) Bi-directional
PERFORMANCE CURVE
Pressure drop
33 cSt[154 SUS] hyd.oil@38° C[100° F]
psi bar
203 14
174 12
145 10
P-A-B-T, P -B-A-T
116 8
87 6
58 4
29 2
0 0
l/min 0 10 20 30 40 50 60 70 80 90 100 110 120
gal/min 0 2.6 5.3 7.9 10.6 13.2 15.9 18.4 21.1 23.7 26.4 29.1 31.7
P108 309E
FD - 8 11141721 • Rev AB • May 2014
Table of Contents/Introduction Quick Reference Index
Dimensions mm [in]
DIMENSION DRAWING
122.4
[4.82]
11.0 164.1
APPROX
[0.43] 86.0 [6.46]
[3.39] 108.0 APPROX
11.0
109.0 [4.25] [0.43] 70.0
9.0 [4.29]
[0.35] 86.0 [2.76]
[3.39]
26.7 9.0
[1.05] [0.35]
100.8
[3.97]
43.0 10.3 [.406] 161.5
73.0 82.8
[1.69] THRU 90.0 108.0 [3.26] [6.36]
[2.87] 31.0
TYPICAL APPROX
127.0 [3.54] [4.25] [1.22]
4 PLACES
[5.00]
P108 310E
EXAMPLE CIRCUITS
OPERATION
This HIC regulates fan speed by controlling pressure drop across the fan motor. It
operates in a normally closed configuration in the absence of an electrical signal. The HIC
reverses flow to the fan motor to reverse fan direction. It includes a DV15-P5-FD open
transition spool valve to reduce pressure spikes during reversals. Internal and external
piloting options are available. This HICs trims the maximum motor torque by absorbing
pressure spikes at the work ports. An anti-cavitation feature allows additional flow to the
motor when the motor over-runs the pump.
APPLICATIONS SCHEMATICS
SPECIFICATIONS
FD - Fan Drive HICs
PERFORMANCE CURVES
DIMENSION DRAWING
Dimensions mm [in]
ORDERING
INFORMATION
CAV:
PRV replaced
by cavity
plug.
OPERATION
The RFD-120-PRV regulates fan speed by controlling pressure drop across the fan
motor. It operates in a normally closed configuration in the absence of an electrical
signal. This HIC reverses flow to the fan motor to reverse fan direction. It includes open
transition spools in the directional valves to reduce pressure spikes during reversals.
The RFD-120-PRV trims the maximum motor torque by absorbing pressure spikes at
the work ports. An anti-cavitation feature allows additional flow to the motor when the
motor over-runs the pump.
APPLICATIONS SCHEMATIC
SPECIFICATIONS
RFD-120-PRV
PERFORMANCE CURVES
Pressure drop
33 cSt[154 SUS] hyd.oil@38° C[100° F] Pressure drop
psi bar
psi bar 33 cSt[154 SUS] hyd.oil@38° C[100° F]
203 14 30 0 W
4000
174 12
U
25 0
S R
3000
∆ Pressure
145 10
20 0
P-A-B-T, P -B-A-T Q O
116 8
2000 150 M
87 6
I
100 F
58 4 1000
50
29 2
0 0
0 0 04 08 01 20 160 l/mi n
0 10 20 30 40 50 60 70 80 90 100 110 120
l/min
0 4 8 12 16 2 0 gal/min
gal/min 0 2.6 5.3 7.9 10.6 13.2 15.9 18.4 21.1 23.7 26.4 29.1 31.7 Bypass flow
FD - 12 11141721 • Rev AB • May 2014
Table of Contents/Introduction Quick Reference Index
DIMENSION DRAWING
Dimensions mm [in]
129.4
176.8
11.0 [5.09]
[6.96]
103.0 APPROX
[0.43] APPROX 82.7
[4.06] 125.0
121.7 [4.92] [3.26]
9.0
[4.79] 103.0
[0.35] 11.0
[4.06]
[0.43]
113.6 26.8
[4.47] [1.05] 9.0 31.0
[0.35] [1.22]
55.7 223.6
[2.19] 10.3 [.406] [8.80]
90.0 100.0
THRU 107.0 125.0 [3.94] APPROX
[3.54]
139.7 TYPICAL [4.21] [4.92]
[5.50] 4 PLACES
P108 318E
EXAMPLE CIRCUITS