SERVICE REPORT
Pemberitahuan :
1. Pastikan seluruh data / keterangan dalam keadaan tercatat dan
didokumentasikan dalam foto. Apabila lembaran pada Laporan ini
tidak mencukupi, silahkan menambahkan data / keterangan pada
lembaran lain dan sertakan dalam laporan ini.
Notification :
1. Make sure all data / information is recorded on writing or photo
documentation. If provided shests are not adequate, please ask data /
information to other sheets and attach to this report.
PT. PANCARAN MARITIM TRANSPORTINDO
Vessel Name : TB P III - 615 Engine Model : C-18 Cert Ditta
Unit Location Engine : PORT
Application TB Arrangement : 020/MNTC
Service Meter :
REPORT CONTENT :
• COMPLETION ......................................................................................................................................................
PT. PANCARAN MARITIM TRANSPORTINDO
Vessel Name : TB P III - 615 Engine Model : C-18 Cert Ditta
Unit Location Engine : PORT
Application TB Arrangement : 020/MNTC
Service Meter :
PHOTO Inspected
No P/N Qty PARTS GROUP/LOCATION
YES NO by
Summary of Inspection
Summary of Repair/Rebuild
LEAK TEST
Date of test :
Tested by :
Supervised by :
Procedure :
1. Tutup salah satu ujung core (aftercooler atau cooler) dengan plat/plug
Close one end of core (aftercooler or cooler) tube with blanking plate.plug, etc
2. Hubungkan ujung lainnya dengan udara bertekanan
Connect the other tub with pressurized air
3. Pastikan tidak ada kebocoran dengan udara bertekanan
Make sure there`s no leak at all connectins
4. Atur tekanan udara pada regulator
15 psi untuk aftercooler ( tekanan pada cooling system )
100 psi untuk oilcooler ( tekanan pada oil pressure )
Dilarang melebihi tekanan di atas, untuk menghindari kerusakan pada core
Set the air pressure regilator at :
15 psi for aftercooler ( pressure at cooling system )
100 psi for oilcooler ( pressure at oil pressure )
To avoid damage for core, do not exceed the pressure above the limit
5. Selama pemberian udara bertekanan, core direndam dalam air selama 30 menit.
Pemeriksaan apakah ada gelembung udara yang mengindikasikan adanya kebocoran
During pressurising the core, submerge the core into the water for 30 menutes
Check for air bubbles appearance that indicate leaking
PT. PANCARAN MARITIM TRANSPORTINDO
Vessel Name : TB P III - 615 Engine Model : C-18 Cert Ditta
Unit Location : Engine : PORT
Application TB Arrangement : 020/MNTC
Service Meter :
6. Memberikan tekanan pada gauge 20 kpa (3 psi) lebih tinggi dari tekanan pada presseure cap
Get pressure reading on the gauge to 20 kpa (3 psi )more then pressure on the pressure cap
7. Cek kebocoran pada bagian luar radiator
Check the radiator for outside leakage
8. Cek semua sambungan dan hose dari kebocoran
Check all connections and hoses for the cooling system for outside leakage
9. Jika tidak terjadi kebocoran, dan tekanan pada gauge tetap sama selama 5 menit, maka Radiator dan cooling system
tidak terjadi kebocoran
If you do not see any outside leakage and the pressure reading on the gauge is still the same after 5 minutes, the
radiator and cooling system does not have leakage
10. Dokementasikan photo kebocoran
Take picture of leaking
PT. PANCARAN MARITIM TRANSPORTINDO
Vessel Name : TB P III - 615 Engine Model : C-18 Cert Ditta
Unit Location Engine : PORT
Application TB Arrangement : 020/MNTC
Service Meter :
INJECTOR INSPECTION
Injector No. 1 2 3 4 5 6
NOT GOOD Visual NOT NOT NOT NOT NOT GOOD
Inspection GOOD GOOD GOOD GOOD GOOD
Comments
Injector YES YES YES YES NO
YES
Replacement
Inspected By :
Comment:
BASE ON VISUAL INSPECTION, THE BODY INJECTORS STILL GOOD. BUT AFTER
PERFORM INJECTOR CUT OUT, FOUND THE INJECTOR NO 1-6 IS NOT GOOD
ENGINE REBUILD SERVICE
CYLINDER BLOCK INSPECTION
1
2
3
4
5
6
7
Reusability Reason / Comment Action Required
CRANKSHAFT INSPECTION FORM
6-7
DATE
By ROTATION : STANDARD-ccw cw
(VIEW FROM FLYWHEEL)
PT. PANCARAN MARITIM TRANSPORTINDO
Vessel Name : TB P III - 615 Engine Model : C-18 Cert Ditta
Unit Location Engine : PORT
Application TB Arrangement : 020/MNTC
Service Meter :
END PLAY
Actual : 0.21mm
Checked By :
PT. PANCARAN MARITIM TRANSPORTINDO
Vessel Name : TB P III - 615 Engine Model : C-18 Cert Ditta
Unit Location Engine : PORT
Application TB Arrangement : 020/MNTC
Service Meter :
PISTON INSPECTION
Reusability
If parts are reusable, put “√” in the box.
If parts are worn normally but are out of the specification, pu “X” in the box
Piston No →
1 Crown
2 Ring Grooves
3 Top ring Lands
4 Skirt
5 Pin Bore
6 Snap Ring
Reusability(Y/N)
Grooves
Note: Refer to GRPTS SEBF8059-16 for Correct Specification
Number of replaced :6
Number of reuse :0
Date of inspection :
Inspected by :
If rod/Pin is good put √ in rod reusability column and put X if rod is bad.
PT. PANCARAN MARITIM TRANSPORTINDO
Vessel Name : TB P III - 615 Engine Model : C-18 Cert Ditta
Unit Location Engine : PORT
Application TB Arrangement : 020/MNTC
Service Meter :
LINERS INSPECTION
Number of replaced :6
Number of reuse :0
Date of inspection :
Inspected by :
PT. PANCARAN MARITIM TRANSPORTINDO
Vessel Name : TB P III - 615 Engine Model : C-18 Cert Ditta
Unit Location Engine : PORT
Application TB Arrangement : 020/MNTC
Service Meter :
Table of specification :
A
B Date of inspection: ……...........
A+B
2 Inspected by:.
A-B
C
D
......................................................................................................................................................................................
.......................................................................................................................................................................................
PT. PANCARAN MARITIM TRANSPORTINDO
Vessel Name : TB P III - 615 Engine Model : C-18 Cert Ditta
Unit Location Engine : PORT
Application TB Arrangement : 020/MNTC
Service Meter :
PHOTO TAG
Turbo charger clean up New cyl liner and piston has The new ring piston and conrod
been installed bearing has been assembly
PT. PANCARAN MARITIM TRANSPORTINDO
Vessel Name : TB P III - 615 Engine Model : C-18 Cert Ditta
Unit Location Engine : PORT
Application TB Arrangement : 020/MNTC
Service Meter :
Replace Main bearing and Jet spray has been installed Conrod bolt has been torqued
thrust plate
New reman injectors ready to Valve lash adjustment Setting fuel injector
installed
View of AE after completion Install new rear crankshaft seal Re-clean up cylinder head
PT. PANCARAN MARITIM TRANSPORTINDO
Vessel Name : TB P III - 615 Engine Model : C-18 Cert Ditta
Unit Location Engine : PORT
Application TB Arrangement : 020/MNTC
Service Meter :