Measurement of Optical
Signal to Noise Ratio in
Coherent Systems using
Polarization Multiplexed
Transmission
Measuring Optical Signal-to-Noise-Ratio (OSNR) in live Dense
Wavelength Division Multiplexing (DWDM) systems using polarization
multiplexed transmission (Pol-Mux) is an unsolved challenge. In this paper
a novel method to calculate OSNR from the correlation between spectral
components in the optical spectrum of a transmission signal is proposed.
Figure 2: Effect of filtered noise in a ROADM system Up to now, there has been no commercially available method
to measure in-service, in-band OSNR in coherent systems with
Pol-Mux.
Signal correlation: Figure 4 shows the spectrum of a 100 Gb/s Pol-Mux quadrature
The measurement samples from signal (yellow samples) show phase shift keying signal (PM-QPSK). Spectral density SPL and
high coincidence whether measured at a ‘1’ or at a ‘0’ state. SPR represent the measured spectral components inside the
The correlation coefficient will therefore be Corr = 1. optical channel that include both, signal and noise.
Noise correlation:
The correlation coefficient Corr can then be expressed as a
Taking similar samples from white noise (blue samples) shows
function of SPL and SPR with a value between 0 and 1, and
that the probability to capture two identical amplitude values
is very low, resulting in a correlation coefficient of Corr = 0.
A mixture of signal and noise will therefore give a correlation
𝐶𝐶𝐶𝐶𝐶𝐶𝐶𝐶 = 𝑓𝑓 (𝑆𝑆!" , 𝑆𝑆!" )
coefficient between 0 and 1 indicating the relationship
between signal and noise which can also be expressed as The in-band OSNR (OSNRC) can be calculated from Corr:
signal-to-noise ratio.
𝑂𝑂𝑂𝑂𝑂𝑂𝑂𝑂! = 𝑓𝑓 (𝐶𝐶𝐶𝐶𝐶𝐶𝐶𝐶)
This is an example in the time domain. As mentioned above,
methods in the time domain need high speed optical receivers Low Corr values indicate low OSNR and high Corr values
which will not work at a system’s monitor points. Using the indicate high OSNR.
Fourier transformation enables performing the correlation
analysis in the frequency domain.
Conclusion
OSNR is still the key parameter to characterize the quality
Figure 5: OSCA-710 block diagram T-BERD/MTS-8000
of modulated optical transmission signals. In this paper we
with OSCA-710 have shown that commonly available methods for measuring
OSNR are not applicable for high speed coherent systems in a
ROADM network topology. The VIAVI Pol-Mux OSCA-710 is the
Measurement results first instrument to use a novel spectral correlation technique
The measurement of in-service, in-band OSNR with 100 Gb/s to enable the measurement of in-band OSNR, and per channel
and 200 Gb/s coherent signals has been performed with the chromatic dispersion of 40 Gb/s, 100 Gb/s, 200 Gb/s and 400
VIAVI Pol-Mux OSCA-710. As a reference measurement for Gb/s coherent transmission signals utilizing Pol-Mux in a live
OSNR, the out-of-service, On/Off OSNR method was used. system. The method is independent of modulation format and
Figure 6 shows the relationship of measured in-band OSNR data rate and is tolerant of large amounts of CD and PMD as
based on VIAVI SCorM (OSNRC) to the reference OSNR well as spectral filtering in ROADMs.
measured with the On/Off method (OSNROn/Off) for a 100 Gb/s The VIAVI SCorM method enables the first ever measurements
PM-QPSK signal at a symbol rate of 28 Gbaud in a 400 km link. of in-band OSNR in live, coherent systems with Pol-Mux. The
OSCA-710 will significantly simplify optical testing during
installation, commissioning and maintenance, and minimize
overall system downtime and man-hours.