You are on page 1of 3

San Telequip (P) Ltd.

,
4 Crystal House, 235, Navi Peth
Off LBS Road, Pune 411 030, India
Phone : 91-20- 24320023, 24334423, 65001587 Connecting. Converting. Leading!
email : info@santelequip.com .
BMS Automation Protocol Converter
BMS Converter is an external Building and Industrial Automation multi-
protocol device server for OEMs wanting to provide protocol
translation between Serial-Serial, Serial-Ethernet and Ethernet-
Ethernet devices using Lon Works®, BACnet, Metasys N2, Modbus
and more.

The Converter includes all the hardware and software to enable the
customer’s products to interface to various networks. Each Bacnet
Converter is provided with the necessary protocol drivers. Multiple drivers can be installed on a single
Converter. We can provide custom driver support when needed.

Features/Benefits
 The most flexible and versatile multi-protocol Device Server on the market.
 Supports virtual nodes allowing multiple OEM controllers to connect to a single converter and
seen as separate controllers on the various field networks.
 TRUE protocol translation and not Protocol packet Encapsulation.
 Interfaces to over 85 Building and Industrial Automation Protocols.
 Multi-Client and Multi-Server support ensures interoperability between any Industrial and or
Building Automation protocols.
 Flash upgradeable.

Specifications
SERIAL PORT :1
RS-485, 2 Wire, 2 Pin Screw type terminal.
SERIAL PORT : 2 (Optional depending on the second Protocol selected)
RS-485, 2 Wire, 2 or 3 Pin Screw type terminal.
Ethernet Port : 1. 10/100 Ethernet port
Connector : RJ45

Indications : LED’s for Tx, Rx, Power

Power : 24V DC, Range 18 to 30 VDC. 100mA @ 24V DC


Connector : 2 Pin Screw type

Environmental
Operating Temp :-40C to 85C
Relative Humidity : 5-90% RH, non-condensing

Enclosure
Dimensions : L x W x H: 10.0 x 7.0 x 4.2 cm (GW BMS01 &02)
: L x W x H: 9.7 x 8.1 x 4.2 cm (GW BMS 04).
Mounting : DIN Rail

Page 1 of 3
San Telequip (P) Ltd.,
4 Crystal House, 235, Navi Peth
Off LBS Road, Pune 411 030, India
Phone : 91-20- 24320023, 24334423, 65001587 Connecting. Converting. Leading!
email : info@santelequip.com .
Supported Host Side Protocols
RS-485 Ethernet (10/100Base-T) to the OEM’s
Modbus RTU device:
Allen Bradley DF1 Allen Bradley Ethernet/IP
BACnet MS/TP BACnet IP
Metasys N2 BACnet Ethernet
LON Modbus TCP/IP

Supported field protocols: Automation Protocols


RS-485 Ethernet (10/100BaseT)
Allen Bradley DF1 Allen Bradley CSP
DNP 3.0 GE-EGD
TL1 GE-SRTP
Telnet OPC, SNMP

Page 2 of 3
San Telequip (P) Ltd.,
4 Crystal House, 235, Navi Peth
Off LBS Road, Pune 411 030, India
Phone : 91-20- 24320023, 24334423, 65001587 Connecting. Converting. Leading!
email : info@santelequip.com .

Ordering Information:

MODEL NO PROTOCOLS
GW BMS 01 Modbus RTU BACnet IP
GW BMS 01-02 Modbus RTU BACnet IP
2 RS485 Ports
GW BMS 02 BACnet MSTP BACnet IP
GW BMS 02-02R BACnet MSTP BACnet IP
BACnet ROUTER 2 RS485 ports
GW BMS 03 Lon Works BACnet IP
GW BMS 04-A Modbus RTU Metasys N2
GW BMS 04-B Metasys N2 BACnet IP
GW BMS 04-B-02 Metasys N2 BACnet IP
2 Serial Ports
GW BMS 04-C BACnet MSTP Metasys N2
GW BMS 04-D BACnet MSTP Modbus RTU
GW BMS 05-A BACnet IP Modbus TCP
GW BMS 05-B SNMP BACnet IP
GW BMS 05-C SNMP Modbus TCP

NOTE:
1. 32 devices can be multidropped on the Modbus RTU / BACnet MSTP / N2 side
2. Depending on site conditions this figure may increase or decrease
3. 485 Repeater may have to used in between the 485 chain to meet basic 485 criteria’s
4. Max 1500 points can be mapped from Modbus RTU to BACnet IP & vice versa.
5. 750 SNVT’s can be mapped on LON Gateway

Page 3 of 3