Professional Documents
Culture Documents
2016)
Free Standard provided by BIS via BSB Edge Private Limited to Government of Telangana -
Hyderabad(rajuanthati25091973@gmail.com) 103.125.163.247 [for non-commercial use only].
(Reaffirmed 2015)
IS 302-2-203 : 1994
( Reaffirmed 2004 )
(Reaffirmed 2014)
(Reaffirmed 2014)
~n::~T (Reaffirmed 2019)
-:>
(Reaffirmed 2012)
Indian Standard
SAFETY OF HOUSEHOLD AND SIMILAR
ELECTRICAL APPLIANCES (Reaffirmed 2011)
(Reaffirmed 2009)
UDC 64J62 : 654 '923-83
(Reaffirmed 2008)
(Reaffirmed 2007)
(Reaffirmed 2006)
(Reaffirmed 2005)
() BIS 1994
FOREWORD
This Tndian Standard was adopted by the Bureau of Indian Standards, after the draft finalized by
the Electrical Appliances Sectional Committee had been approved by the Electrical Division
Council.
This standard covers general and safety requirements of Electric Call Bells and Buzzers for indoor
use. The performance requirement including general and safety requirements are covered under a
separate Indian Standard IS 2268 : 1988 Specificatio n for electric call bells and Buzzers for indoor
use.
This standard is to be read in conjunction with IS 302-1 ( 1979), For the sake of convenience,
the clauses of this standard correspond to those of IS 302-1 ( 1979), Instead or reproducing full
text of each clause , clauses 01 IS 302-1 ( 1979 ) which are applicable (which means that relevant
provisions of the clause apply) or not applicable and the sub-clauses or portions thereof wbicb are
not applicable are indicated as under:
a) In case of clause, where it is applicable or not applicable, the wording used is 'This clause
of IS 302-1 ( 1979 ) is applicable/not applicable',
Wherever a sub-clause of IS 302-1 ( 1979) is to be replaced by a new text, it has been indicated
as under:
Anv addition to the e" isting provisions of a sub-clause of IS 302-1 ( 1979) has been indicated ••
under:
Clausesltables which are additional to those of IS 302-1 ( 1979) are numbered starting from 101
and additional sub-clauses are numbered with the main clauses number followed by 101, 102, etc, for
example 7,101.
Should however, any deviation exists between IS 302-1 (1979) and this standard, the provisions of
the latter shall apply,
While preparing this standard assistance was derived from 1EC 335-1 ( 1976) Safety of household
and similar electrical equipment: Part I General requirement, issued by International
Electrotechnical Commission.
The I ndian Standards which are necessary adjuncts to this standard are given in Annex AA,
For the purpose of deciding whe:her a particular requirement of this standard is complied with, Ihe
final value, observed or calculated, expressing the result of a test or analysis, shall be rounded off
in accordance with IS 2: 1960 'Rules for rounding off numerical values (revised)', Tbe number
of significant places retained in the rounded ·off value should be Ihe same as that of tbe specified
value in th is standard,
Free Standard provided by BIS via BSB Edge Private Limited to Government of Telangana -
Hyderabad(rajuanthati25091973@gmail.com) 103.125.163.247 [for non-commercial use only].
IS 302·2·203 : 1994
Indian Standard
SAFETY OF HOUSEHOLD AND SIMILAR
ELECTRICAL APPLIANCES
PART 2 PARTICULAR REQUIREMENTS
Section 203 Electric Call Bells and Buzzers for Indoor Use
1 SCOPE 5 RATING
This clause of IS 302·1 (1979) is applicable except This clause of IS 302-1 (1979) is applicable except
as follows: as follows:
1.1 This standard covers the general and safety 5.1 Replacement
requirements for electrically operated call bells and
buzzers for indoor use designed for connection to Rated Voltage - The rated voltage sball not
supplies at voltages not exceeding 250 V ac single exceed 250 V and shall preferably be 240 V.
phase 50 cIs or dc.
5.2 Not applicable.
2 TERMINOLOGY
6 CLASSIFICATION
This clause of IS 302·1(1979) is applicable except
as follows: This clause. of IS 302-1 (1979) is applicable.
2.8 to 2.11, 2.18, 2.19, 2.21 to 2.25 and 2.28 not 7 MARKING
applicable. This clause of IS 302-1 (1979) is applicable except
as follows:
2.29 Replacement
Conditions of Adequate Heat Discharge - 7.1 Replacement
The conditions which apply when the electric
call bell and buzzer is operated under normal Eacb electric call bell and buzzer sball be marked
condition of use. with the following information.
a) Rated voltage;
2.30 to 2.33, 2.37 to 2.41 and 2.46 not applicable.
b) Symbol for nature of supply, if applicable;
Additional sub-clauses c) Rated frequency;
d) Rated input in watts;
2.101 Call Bell
e) Maker's or vendor's name or trade-mark;
A signalling device in wbicb a bammer is actuated
so as to strike a gong, bell, pipe, strip, etc. f) Model or type reference;
g) Symbol for Class II construction, if applicable;
2. 102 Buzzer h) Symbol for degree of protection, if applicable;
A singnalling device similar to all electric bell but and
without a hammer or gong. and serving to produce j) Country of origin.
sound by tbe vibration of an armature.
7.2 and 7.4 to 7.12 not applicable.
3 GENERAL REQUIREMENT 7.101 Additional Sub·clause
This clause of IS 302-1 (1979) is applicable except
The electric call bells or buzzers may also be marked
as follows:
witb the Standard Mark.
3.1 Para 2 not applicable.
7.102 The use of tbe Standard Mark is governed by
tbe provisions of Bureau of Indian Standards Act,
4 GENERAL NOTES ON TESTS 1986 and the Rules and Regulations made tbereunder.
The details of conditions under whicb tbe licence
This clause of IS 302-1 (1979) is applicable except for the use of Standard Mark may be granted to
as folluws: manufacturers or producers may be obtained from
4.3 Note 2 and 4.7 to 4.14 not applicable. tbe Bureau of Indian Standards.
1
Free Standard provided by BIS via BSB Edge Private Limited to Government of Telangana -
Hyderabad(rajuanthati25091973@gmail.com) 103.125.163.247 [for non-commercial use only].
IS 302-2-203 : 1994
8 PROTECTION AGAINST ELECTRIC in normal use sball not be excessive, compliance is
SHOCK cbecked by tests given in 13.2. The tests are made
when the call bell or buzzer is connected to lbe
This clause of IS 302-1 (1979) is applicable except supply.
as follows:
8.2 to 8.9 not applicable. 13.4 Not applicable.
10 INPUT AND CURRENT In case the electric call bell or buzzer contains a
contact breaker, it sball include a radio interference
This clause of IS 302-1 (1979) is not applicable. suwression capacitor. This shall, however, not adversely
affect tbe safety of tbe appliance.
11 TEMPERATURE-RISE
IS MOISTURE RESISTANCE
This clause of IS 302-1 (1979) is applicable except
as follows: This clause of IS 302-1 (1979) is applicable except
as follows:
11.2 to 11.6 not applicable.
IS. 1 to 15.3 not applicable
11.7 Replacement
16 INSULATION RESISTANCE AND
The call bell or buzzer is operated on consecutive ELECTRIC STRENGTH (AFTER HUMIDITY
cycles of operation until steady conditions are TREATMENT)
establisbed under nonnal conditions of use.
This clause of IS 302-1 (1979) is applicable except
ll.s Para I and 2 Replacement as follows .
The measurements specified in 13.1 are made at tbe Compliance is checked by tests given in 16.2 and
end of tbis test. 16.4 wbich are made on tbe call bell or buzzer after
the test in 15.4 in tbe humidity cabinet or in the room
ll.9 and ll.IO not applicable. in wbich the sample was brought to the prescribed
temperature after reassembly of tbose parts which
Additional Sub-clause may have been removed .
2
Free Standard provided by BIS via BSB Edge Private Limited to Government of Telangana -
Hyderabad(rajuanthati25091973@gmail.com) 103.125.163.247 [for non-commercial use only].
IS 302-2-203 : 1994
sine wave form having a frequency of 50 or 60 Hz. 27 PROVISION FOR EARTHING
The value ofthc \Cst voltage and the points of application
are shown in the ta ble. This clause of IS 302-1 (1979) is applicable except
as follows:
17 OVERI~OAD PROTECTION
27.3 not applicable.
This clause of IS 302-1 (1979) is not applicable.
28 SCREWS AND CONNECTIONS
18 ENDURANCE (under consideration)
This clause of IS 302-1 (1979) is applicable.
19 ABNORMAL OPERATION
29 CREEPAGE DISTANCES AND
CLEARANCES
This clause of IS 302-1 (1979) is not applicable.
This clause of IS 302-1 (1979) is applicable .
20 STABllXrv AND MECHANICAL HAZARDS
30 RESISTANCE TO HEAT, FIRE AND
This clause of IS 302-1 (1979) is not applicable. TRACKING
21 MECHANICAL STRENGTH This clause of IS 302-1 (1979) is applicable.
This clause of IS 302-1 (1979) is applicable except 31 RESISTANCE TO RUSTING
os follows:
This clause of IS 302-1 (1979) is applicable.
21.2 to 21.4 not applicable.
32 RAOIATION HAZARD
22 CONSTRUCTION
This clause of IS 302-1 (1979) is applicable.
This clause of IS 302-1 (1979) is applicable except
as follows: 101 TESTS
22.4,22.7,22_9 to 22.12, 22.15, 22.16, 22.18, 22.20, 101.0 Categories of Tests
22.23 to 22.27 and 22.29 to 22.32 not applicable.
Tests are classified as type, acceptance and routine
23 INTERNAL WIRING tests.
3
Free Standard provided by BIS via BSB Edge Private Limited to Government of Telangana -
Hyderabad(rajuanthati25091973@gmail.com) 103.125.163.247 [for non-commercial use only].
IS 302-2·203 : 1994
101.2 Accepmnce Tests 101.2.1 A recommended sampling procedure for
acceptance tests is given in Appendix B of
The following shall constitute the acceptance tests: IS 302-1 (1979).
( Clause 101.1 )
SI Test Clause
No. RctueD.ce
4
Free Standard provided by BIS via BSB Edge Private Limited to Government of Telangana -
Hyderabad(rajuanthati25091973@gmail.com) 103.125.163.247 [for non-commercial use only].
IS 302·2.203 : 1994
ANNEX A
TABLES OF TYPE TESTS
ANNEX B
SAMPLING PROCEDURE FOR ACCEPTANCE TEST
ANNEX C
ELECTRONIC CIRCUITS
ANNEX D
MEASUREMENT OF TEMPERATURE WITH THERMOMETER
ANNEX E
ALTERNATIVE TESTS FOR PROTECTED MOTOR UNITS
ANNEX F
IMPACT TEST APPARATUS
5
Free Standard provided by BIS via BSB Edge Private Limited to Government of Telangana -
Hyderabad(rajuanthati25091973@gmail.com) 103.125.163.247 [for non-commercial use only].
IS JOZ-Z-Z03 : 1994
ANNEX G
THERMAL CENTRAL AND , OVERLOAD RELEASES
ANNEX H
MEASUREMENT OF CREEPAGE DISTANCES AND CLEARANCES
ANNEX J
TEST .-OR FIRE-RESISTING PROPERTIES
ANNEX K
BNF JET TEST FOR DETERMINATION OF THICKNESS OF COPPER
AND NICKEL PLATING
ANNEX L
APPROXIMATE MEASUREMf:NT ,m- THICKNESS OF CHROMIUM ON NICKEL,
. ,. . STEEL AND COPPER
Appendix L of IS 302-1 (1979) is not applicable.
ANNEX AA
IS No. Tille
6
Free Standard provided by BIS via BSB Edge Private Limited to Government of Telangana -
Hyderabad(rajuanthati25091973@gmail.com) 103.125.163.247 [for non-commercial use only].
Copyright
BIS has the copyright of all its publications. No par! of these publications may be reproduced in
any form without the prior permission in writing of B[S. This doel not preclude the free use, in the
course of implementing the standard, of necessary details. such as symbols and sizes, type or grade
delignations. Enquiries relating to copyright be addressed to the Director ( Publication. ), BIS.
Headq uarten:
Manak Bhavan, 9 Bahadur Shah Zafar Marg, New Delhi 110002
TeleDhones: 33101 31, 331 1375 Telegraml : Manaksanlth.
( Common to .11 Office. )