You are on page 1of 9

(Reaffirmed 

2016) 
Free Standard provided by BIS via BSB Edge Private Limited to Government of Telangana -
Hyderabad(rajuanthati25091973@gmail.com) 103.125.163.247 [for non-commercial use only]. 

(Reaffirmed 2015) 
IS 302-2-203 : 1994
 
( Reaffirmed 2004 )
(Reaffirmed 2014) 
(Reaffirmed 2014)
~n::~T (Reaffirmed 2019)
-:>
 

'IlT1T 2 fm aAe'f~ (Reaffirmed 2013) 

~'llllT ,)203 an;ffi~ ~Tm ~ ~ f,{~"'-m:r-~r <NT <I'\i\jf~  

(Reaffirmed 2012) 
Indian Standard
 
SAFETY OF HOUSEHOLD AND SIMILAR
ELECTRICAL APPLIANCES (Reaffirmed 2011) 

PART 2 PARTICULAR REQUIREMENTS  


Section 203 Electric Call Bells and Buzzers for Indoor Use
(Reaffirmed 2010) 

(Reaffirmed 2009) 
UDC 64J62 : 654 '923-83
 

(Reaffirmed 2008) 

(Reaffirmed 2007) 

(Reaffirmed 2006) 

(Reaffirmed 2005) 

() BIS 1994

BUREAU OF INDIAN STANDARDS


MANAK SH AVAN . 9 BAHADUR SHAH ZAFAR MARG "
N EW DELHI 110002
April 1994 Price Group 3
Free Standard provided by BIS via BSB Edge Private Limited to Government of Telangana -
Hyderabad(rajuanthati25091973@gmail.com) 103.125.163.247 [for non-commercial use only].

Electrical Appliances Sectional Committee, ETD 32

FOREWORD

This Tndian Standard was adopted by the Bureau of Indian Standards, after the draft finalized by
the Electrical Appliances Sectional Committee had been approved by the Electrical Division
Council.

This standard covers general and safety requirements of Electric Call Bells and Buzzers for indoor
use. The performance requirement including general and safety requirements are covered under a
separate Indian Standard IS 2268 : 1988 Specificatio n for electric call bells and Buzzers for indoor
use.

This standard is to be read in conjunction with IS 302-1 ( 1979), For the sake of convenience,
the clauses of this standard correspond to those of IS 302-1 ( 1979), Instead or reproducing full
text of each clause , clauses 01 IS 302-1 ( 1979 ) which are applicable (which means that relevant
provisions of the clause apply) or not applicable and the sub-clauses or portions thereof wbicb are
not applicable are indicated as under:

a) In case of clause, where it is applicable or not applicable, the wording used is 'This clause
of IS 302-1 ( 1979 ) is applicable/not applicable',

b) Tn case of a sub-clause or part thereof 'Not applicable',

Wherever a sub-clause of IS 302-1 ( 1979) is to be replaced by a new text, it has been indicated
as under:

'Replacement - followed by the new text' ,

Anv addition to the e" isting provisions of a sub-clause of IS 302-1 ( 1979) has been indicated ••
under:

'Addition - followed by the text of the additional matter',

Clausesltables which are additional to those of IS 302-1 ( 1979) are numbered starting from 101
and additional sub-clauses are numbered with the main clauses number followed by 101, 102, etc, for
example 7,101.

Should however, any deviation exists between IS 302-1 (1979) and this standard, the provisions of
the latter shall apply,

While preparing this standard assistance was derived from 1EC 335-1 ( 1976) Safety of household
and similar electrical equipment: Part I General requirement, issued by International
Electrotechnical Commission.

The I ndian Standards which are necessary adjuncts to this standard are given in Annex AA,

For the purpose of deciding whe:her a particular requirement of this standard is complied with, Ihe
final value, observed or calculated, expressing the result of a test or analysis, shall be rounded off
in accordance with IS 2: 1960 'Rules for rounding off numerical values (revised)', Tbe number
of significant places retained in the rounded ·off value should be Ihe same as that of tbe specified
value in th is standard,
Free Standard provided by BIS via BSB Edge Private Limited to Government of Telangana -
Hyderabad(rajuanthati25091973@gmail.com) 103.125.163.247 [for non-commercial use only].

IS 302·2·203 : 1994

Indian Standard
SAFETY OF HOUSEHOLD AND SIMILAR
ELECTRICAL APPLIANCES
PART 2 PARTICULAR REQUIREMENTS

Section 203 Electric Call Bells and Buzzers for Indoor Use

1 SCOPE 5 RATING

This clause of IS 302·1 (1979) is applicable except This clause of IS 302-1 (1979) is applicable except
as follows: as follows:

1.1 This standard covers the general and safety 5.1 Replacement
requirements for electrically operated call bells and
buzzers for indoor use designed for connection to Rated Voltage - The rated voltage sball not
supplies at voltages not exceeding 250 V ac single exceed 250 V and shall preferably be 240 V.
phase 50 cIs or dc.
5.2 Not applicable.
2 TERMINOLOGY
6 CLASSIFICATION
This clause of IS 302·1(1979) is applicable except
as follows: This clause. of IS 302-1 (1979) is applicable.

2.8 to 2.11, 2.18, 2.19, 2.21 to 2.25 and 2.28 not 7 MARKING
applicable. This clause of IS 302-1 (1979) is applicable except
as follows:
2.29 Replacement
Conditions of Adequate Heat Discharge - 7.1 Replacement
The conditions which apply when the electric
call bell and buzzer is operated under normal Eacb electric call bell and buzzer sball be marked
condition of use. with the following information.
a) Rated voltage;
2.30 to 2.33, 2.37 to 2.41 and 2.46 not applicable.
b) Symbol for nature of supply, if applicable;
Additional sub-clauses c) Rated frequency;
d) Rated input in watts;
2.101 Call Bell
e) Maker's or vendor's name or trade-mark;
A signalling device in wbicb a bammer is actuated
so as to strike a gong, bell, pipe, strip, etc. f) Model or type reference;
g) Symbol for Class II construction, if applicable;
2. 102 Buzzer h) Symbol for degree of protection, if applicable;
A singnalling device similar to all electric bell but and
without a hammer or gong. and serving to produce j) Country of origin.
sound by tbe vibration of an armature.
7.2 and 7.4 to 7.12 not applicable.
3 GENERAL REQUIREMENT 7.101 Additional Sub·clause
This clause of IS 302-1 (1979) is applicable except
The electric call bells or buzzers may also be marked
as follows:
witb the Standard Mark.
3.1 Para 2 not applicable.
7.102 The use of tbe Standard Mark is governed by
tbe provisions of Bureau of Indian Standards Act,
4 GENERAL NOTES ON TESTS 1986 and the Rules and Regulations made tbereunder.
The details of conditions under whicb tbe licence
This clause of IS 302-1 (1979) is applicable except for the use of Standard Mark may be granted to
as folluws: manufacturers or producers may be obtained from
4.3 Note 2 and 4.7 to 4.14 not applicable. tbe Bureau of Indian Standards.

1
Free Standard provided by BIS via BSB Edge Private Limited to Government of Telangana -
Hyderabad(rajuanthati25091973@gmail.com) 103.125.163.247 [for non-commercial use only].

IS 302-2-203 : 1994
8 PROTECTION AGAINST ELECTRIC in normal use sball not be excessive, compliance is
SHOCK cbecked by tests given in 13.2. The tests are made
when the call bell or buzzer is connected to lbe
This clause of IS 302-1 (1979) is applicable except supply.
as follows:
8.2 to 8.9 not applicable. 13.4 Not applicable.

9 STARTING OF MOTOR OPERATED 14 RADIO AND TELEVISION


APPLIANCES INTERFERENCE SUPPRESSIONS

This clause of IS 302-1 (1979) in not applicable. 14.1 Replacement

10 INPUT AND CURRENT In case the electric call bell or buzzer contains a
contact breaker, it sball include a radio interference
This clause of IS 302-1 (1979) is not applicable. suwression capacitor. This shall, however, not adversely
affect tbe safety of tbe appliance.
11 TEMPERATURE-RISE
IS MOISTURE RESISTANCE
This clause of IS 302-1 (1979) is applicable except
as follows: This clause of IS 302-1 (1979) is applicable except
as follows:
11.2 to 11.6 not applicable.
IS. 1 to 15.3 not applicable
11.7 Replacement
16 INSULATION RESISTANCE AND
The call bell or buzzer is operated on consecutive ELECTRIC STRENGTH (AFTER HUMIDITY
cycles of operation until steady conditions are TREATMENT)
establisbed under nonnal conditions of use.
This clause of IS 302-1 (1979) is applicable except
ll.s Para I and 2 Replacement as follows .

Ouring tbe test, tbe temperature-rise sball be monitored 16.1 Replacement


continuously and sball not exceed tbe values given
in Table 1 and tbe sealing compound, if any, sball The insulation and electric strength of the appliances
not flow out. sball be adequate.

The measurements specified in 13.1 are made at tbe Compliance is checked by tests given in 16.2 and
end of tbis test. 16.4 wbich are made on tbe call bell or buzzer after
the test in 15.4 in tbe humidity cabinet or in the room
ll.9 and ll.IO not applicable. in wbich the sample was brought to the prescribed
temperature after reassembly of tbose parts which
Additional Sub-clause may have been removed .

ll.101 Call bells or buzzers witb contact breakers 16.2 Replacement


sball satisfy tbis additional requirement tbat witb tbe An ac test voltage is applied as specified in items
rated voltage applied to tbe bell or buzzer and with t to 4 of tbe table of 16.4. The metal foil baving
tbe contact breaker sbort-circuited for a period of five a size not exceeding 20 x 10 cm and being moved,
minutes, tbe temperature of the winding sball not if necessary, so as to test all parts of the surface.
exceed l00'C (the reference ambient temperature being
40"C). The test voltage is J'()6 times tbe upper limit of tbe
rated voltage range for dc only, for single-phase
12 OPERATION UNDER OVERLOAD applicances and for tbree-phase appliances wbicb are
CONDITIONS OF APPLIANCES WITH also suitable for single-phase supply, if the rated
HEATING ELEMENTS voltage or the upper limit of the rated voltage does
not exceed 250 V.
This clause of IS 302-1 (1979) is not applicable. The leakage current measured after the application
of tbe test voltage sball not exceed the value given
13 ELECTRICAL INSULATION AND in 13.2.
LEAKAGE CURRENT AT OPERATING
TEMPERATURE 16.3 Not applicable.
13.1 Replacement 16A Para 1 Replacement
Tbe electrical insulation of tbe appliance at operating hrunediately after the test given in 16.2, the insulation
temperature shall be adequate and the leakage current is subjected for 1 minute to a voltge of substantially

2
Free Standard provided by BIS via BSB Edge Private Limited to Government of Telangana -
Hyderabad(rajuanthati25091973@gmail.com) 103.125.163.247 [for non-commercial use only].

IS 302-2-203 : 1994
sine wave form having a frequency of 50 or 60 Hz. 27 PROVISION FOR EARTHING
The value ofthc \Cst voltage and the points of application
are shown in the ta ble. This clause of IS 302-1 (1979) is applicable except
as follows:
17 OVERI~OAD PROTECTION
27.3 not applicable.
This clause of IS 302-1 (1979) is not applicable.
28 SCREWS AND CONNECTIONS
18 ENDURANCE (under consideration)
This clause of IS 302-1 (1979) is applicable.
19 ABNORMAL OPERATION
29 CREEPAGE DISTANCES AND
CLEARANCES
This clause of IS 302-1 (1979) is not applicable.
This clause of IS 302-1 (1979) is applicable .
20 STABllXrv AND MECHANICAL HAZARDS
30 RESISTANCE TO HEAT, FIRE AND
This clause of IS 302-1 (1979) is not applicable. TRACKING
21 MECHANICAL STRENGTH This clause of IS 302-1 (1979) is applicable.
This clause of IS 302-1 (1979) is applicable except 31 RESISTANCE TO RUSTING
os follows:
This clause of IS 302-1 (1979) is applicable.
21.2 to 21.4 not applicable.
32 RAOIATION HAZARD
22 CONSTRUCTION
This clause of IS 302-1 (1979) is applicable.
This clause of IS 302-1 (1979) is applicable except
as follows: 101 TESTS
22.4,22.7,22_9 to 22.12, 22.15, 22.16, 22.18, 22.20, 101.0 Categories of Tests
22.23 to 22.27 and 22.29 to 22.32 not applicable.
Tests are classified as type, acceptance and routine
23 INTERNAL WIRING tests.

This clause of IS 302-1 (1979) is applicable except 101.1 Type Tests


as follows:
The tests specified in Table 101 shall institute the
23.4 and 23.5 not applicable. type tests and shall be carried out on two samples
of call bell or buzzer of tbe same type and rating
24 COMPONENTS selected, preferably at raudom, from a regular
production lot. Before commencement of the tests,
This clause of IS 302-1 (1979) is applicable except tbe call bell or buzzer sball be visually examined
as follows: and inspected for obvious visual defects in respect
of components, parts and their assembly. construction,
24.2 to 24.10 not applicable. stability, markings, provision of suitable terminals
for supply connections, earthing, and tbe effectiveness
25 SUPPLY CONNECTION, AND EXTERNAL of screws and connections. The external surface finish
FJ~EXIBLECABLES AND CORDS shall be even and free from finishing defects.

This clause of IS 302-1 (1979) is applicable except 101.1.1 Criteria of Acceptance


as follows: All samples sball successfully pass all tbe type tests
25.3 to 25.7 and 25.10 to 25.14 not applicable. for proving conformity witb the requirements of the
standard. If any of tbe samples fails in any of the
type tests, the testing authority, at its discretion, may
26 TERMINAL FOR EXTERNAL call for fresb samples not exceeding twice the original
CONDUCTORS number and subject them again to all tests or to tbe
testes) in which failure(s) occurred. No failure should
This clause of IS 302-1 (1979) is applicable. be pennitted in the repeat testes).

3
Free Standard provided by BIS via BSB Edge Private Limited to Government of Telangana -
Hyderabad(rajuanthati25091973@gmail.com) 103.125.163.247 [for non-commercial use only].

IS 302-2·203 : 1994
101.2 Accepmnce Tests 101.2.1 A recommended sampling procedure for
acceptance tests is given in Appendix B of
The following shall constitute the acceptance tests: IS 302-1 (1979).

Test Clause 101.2(1).2(3) Routine Tests


Reference
The following tests shall constitute the· routine
i) Protection against electric shock 8 tests:
ii) Temperature rise 11
Test Clause
iii) Insulation resistance and Reference
leakage current at operating
temperature 13 a) Protection against electric shock 8
iv) Moisture resjstance 15
v) Insulation resistance and electric b) High voltage 13.3.2 of
strength (after humidity treatment) 16 IS 302-1 (1979)
vi) Provision for earthing 27 c) Provision for earthing 27

Table 101 Schedule of Type Tests

( Clause 101.1 )
SI Test Clause
No. RctueD.ce

;) Protection against electric shock 8


ii) Temperature-rise 11
iii) Electrical insulation and leakage current at operating temperature 13
iv) Radio and television interference suppression 14
v) Mois ture resistance 15
vi) Insulation resistance aDd eJeclric Slrenalh (a rter bumidity treatment) 16
vii) EndutJllnce (under consideration) 18
viii) Mechanical strength 21
ix) Construction 22
,) Internal wirina: 23
xi) Component 24
xii) Su·ppl,Y connection and external flexible cables and cords 25
xiii) Terminal ror external conductor 26
xiv) Earthing 27
xv) Screws and connections 28
xvi) Creepage dis tances and clearance 29
xvii) Resistance 10 heat. fire and tracking 30
xviii) Resistance 10 rusting 31
xix) Radiation hazards 32

4
Free Standard provided by BIS via BSB Edge Private Limited to Government of Telangana -
Hyderabad(rajuanthati25091973@gmail.com) 103.125.163.247 [for non-commercial use only].

IS 302·2.203 : 1994
ANNEX A
TABLES OF TYPE TESTS

Appendix A of IS 302·1 (1979) is nol applica ble.

ANNEX B
SAMPLING PROCEDURE FOR ACCEPTANCE TEST

Appendix B of IS 302-1 (1979) is applicable.

ANNEX C
ELECTRONIC CIRCUITS

Appendix C of IS 302-1 (1979) is applicable, if electronic citcuits are used .

ANNEX D
MEASUREMENT OF TEMPERATURE WITH THERMOMETER

Appendix D of IS 302-1 (1979) is applicable.

ANNEX E
ALTERNATIVE TESTS FOR PROTECTED MOTOR UNITS

Appendix E of IS 302-1 (1979) is nol applicable.

ANNEX F
IMPACT TEST APPARATUS

Appendix F of IS 302-1 (1979) is applicable.

5
Free Standard provided by BIS via BSB Edge Private Limited to Government of Telangana -
Hyderabad(rajuanthati25091973@gmail.com) 103.125.163.247 [for non-commercial use only].

IS JOZ-Z-Z03 : 1994
ANNEX G
THERMAL CENTRAL AND , OVERLOAD RELEASES

Appendix G of IS 302-1 (1979) is not applicable.

ANNEX H
MEASUREMENT OF CREEPAGE DISTANCES AND CLEARANCES

Appendix H of IS 302-1 (1979) is applicable.

ANNEX J
TEST .-OR FIRE-RESISTING PROPERTIES

Appendix J of IS 302-1 (1979) is applicable.

ANNEX K
BNF JET TEST FOR DETERMINATION OF THICKNESS OF COPPER
AND NICKEL PLATING

Appendix K of IS 302-1 (1979) is not applicable.

ANNEX L
APPROXIMATE MEASUREMf:NT ,m- THICKNESS OF CHROMIUM ON NICKEL,
. ,. . STEEL AND COPPER
Appendix L of IS 302-1 (1979) is not applicable.

ANNEX AA
IS No. Tille

302-1(1979) Safety of household and similar electrical appliances: Part I General


requirements (jifth revision)

6
Free Standard provided by BIS via BSB Edge Private Limited to Government of Telangana -
Hyderabad(rajuanthati25091973@gmail.com) 103.125.163.247 [for non-commercial use only].

Bureau of Indian Standards


B[S i. a statutory institution established under the Bu,.au of Indian Standard. Acr, 1986 to promote
barmonioul development of the activities of standardization. marking"and quality certification of good.
and attending to connected matters in the country.

Copyright
BIS has the copyright of all its publications. No par! of these publications may be reproduced in
any form without the prior permission in writing of B[S. This doel not preclude the free use, in the
course of implementing the standard, of necessary details. such as symbols and sizes, type or grade
delignations. Enquiries relating to copyright be addressed to the Director ( Publication. ), BIS.

Revision of Indian Standards


Indian Standards are reviewed periodically and revised, when necessary and amendments, if any, are
issued from time to time. Users of Indian Standards should ascertain that they are in possession 0
the latest amendments or edition.
This Indian Standard has been developed from Doc: No. ETD 32 ( 3748 )

Amendments Issued Since Publication


Amend No. Date of I.sue Text A!fected

BUREAU OF INDIAN STANDARDS

Headq uarten:
Manak Bhavan, 9 Bahadur Shah Zafar Marg, New Delhi 110002
TeleDhones: 33101 31, 331 1375 Telegraml : Manaksanlth.
( Common to .11 Office. )

Regional Officea: Telephone

Centrol : Manak Bhavan, 9 Bahadur Shah Zafar Marg 331 01 31


NEW DELHI 110002 { 331 13 B

Rastern: 1/14 C. I. T. Scheme VII M, V. I. P. Road, Maniktola 37 8499, 37 85 61


CALCUTTA 700054 { 37 86 26, 37 86 62

Northern: SCO 445-446, Sector HoC, CHANDIGARH 160036 53 38 43, 53 16 40


{ 53 23 84
Southern: C. I. T. Cami'u" IV Cross Road, MADRAS 600113 235 02 16, 2350442
{ 235 .1519, 2352315
Wostern : Manakalaya, E9 MIDC, Marol, Andheri ( East) 632 92 95, 632 78 58
BOMBAY 400093 { 6327891, 6327892
Branchel: AHMADABAD. BANGALORE. BHOPAL. BHUBANRSHWAR. COIMBATORE.
FARIDABAD. GHAZIABAD. GUWAHATL HYDERABAD. JAIPUR. KANPUR.
LUCKNOW. PATNA. THIRUVANANTHAPURAM.

PriDted at Priolradc, New Delhi. India

You might also like