You are on page 1of 6

ENGINEERING REPORT R1A

08.MARET.22

ANALISA REINFORCEMENT SHEARWALL


BANGUNAN GEDUNG UMP−PURWOKERTO

UMP PURWOKERTO
BANYUMAS
STRUCTUREPOINT - spColumn v6.00 Page | 1
Licensed to: GNW-MG, -. License ID: -2C9E1 3/6/2022
H:\15.Proyek\PT.PARIKESIT PART II\GEDUNG UMP\SPCOLUMN\SHEARWALL REINFORCEMENT R0.col 11:03 AM

1. General Information
File Name H:\15.Proyek\PT...\SHEARWAL
L REINFORCEMENT R0.col
Project SHEARWALL UMP
Column SHEARWALL
Engineer GN
Code ACI 318-14
Bar Set ASTM 615M
Units Metric
Run Option Investigation
Run Axis X - axis
Slenderness Not Considered
Column Type Architectural

2. Material Properties
2.1. Concrete
Type Standard
f'c 25 MPa
Ec 23500 MPa
fc 21.25 MPa
εu 0.003 mm/mm
β1 0.85

2.2. Steel
Type Standard
fy 400 MPa
Es 200000 MPa
εyt 0.002 mm/mm

3. Section
3.1. Shape and Properties
Type Rectangular
Width 1000 mm
Depth 200 mm
Ag 200000 mm2
Ix 6.66667e+008 mm4
Iy 1.66667e+010 mm4
rx 57.735 mm
ry 288.675 mm
Xo 0 mm
Yo 0 mm

3.2. Section Figure

y
x

Rectangular 1000 x 200 mm 1.99% reinf.

Figure 1: Column section


STRUCTUREPOINT - spColumn v6.00 Page | 2
Licensed to: GNW-MG, -. License ID: -2C9E1 3/6/2022
H:\15.Proyek\PT.PARIKESIT PART II\GEDUNG UMP\SPCOLUMN\SHEARWALL REINFORCEMENT R0.col 11:03 AM

4. Reinforcement
4.1. Bar Set: ASTM 615M
Bar Diameter Area Bar Diameter Area Bar Diameter Area
mm mm2 mm mm2 mm mm2
#10 9.50 71.00 #13 12.70 129.00 #16 15.90 199.00
#19 19.10 284.00 #22 22.20 387.00 #25 25.40 510.00
#29 28.70 645.00 #32 32.30 819.00 #36 35.80 1006.00
#43 43.00 1452.00 #57 57.30 2581.00

4.2. Confinement and Factors


Confinement type Tied
For #32 bars or less #10 ties
For larger bars #10 ties

Capacity Reduction Factors


Axial compression, (a) 0.8
Tension controlled ɸ, (b) 0.9
Compression controlled ɸ, (c) 0.65

4.3. Arrangement
Pattern Sides different
Bar layout Rectangular
Cover to Transverse bars
Clear cover ---
Bars ---

Total steel area, As 3976 mm2


Rho 1.99 %
Minimum clear spacing 83 mm

4.4. Bars Provided


Bars Cover
mm
Top 7 #19 30
Bottom 7 #19 30
Left 0 #19 30
Right 0 #19 30

5. Factored Loads and Moments with Corresponding Capacities


No Pu Mux ɸMnx ɸMn/Mu NA Depth dt Depth εt ɸ
kN kNm kNm mm mm
1 2030.00 26.00 94.55 3.637 139 151 0.00027 0.650
P ( kN)
6000

y
x
(Pmax) (Pmax)
fs=0 fs=0

fs=0.5fy fs=0 fs=0 fs=0.5fy

1
1000 x 200 mm fs=0.5fy fs=0.5fy

Code: ACI 318-14


Units: Metric
Run axis: About X-axis
Run option: Investigation -180 180
Mx ( kNm)
Slenderness: Not considered
Column type: Architectural
Bars: ASTM A615M (Pmin) (Pmin)

Date: 03/06/22 -2000

Time: 11:04:40

STRUCTUREPOINT - spColumn v6.00 (TM). Licensed to: GNW-MG, -. License ID: -2C9E1

File: H:\15.Proyek\PT.PARIKESIT PART II\GEDUNG UMP\SPCOLUMN\SHEARWALL REINFORCEMENT R0.col


Project: SHEARWALL UMP
Column: SHEARWALL Engineer: GN
f'c = 25 MPa fy = 400 MPa Ag = 200000 mm^2 14 #19 bars
Ec = 23500 MPa Es = 200000 MPa As = 3976 mm^2 rho = 1.99%
fc = 21.25 MPa e_yt = 0.002 mm/mm Xo = 0 mm Ix = 6.67e+008 mm^4
e_u = 0.003 mm/mm Yo = 0 mm Iy = 1.67e+010 mm^4
Beta1 = 0.85 Min clear spacing = 83 mm Clear cover = 40 mm
Confinement: Tied
phi(a) = 0.8, phi(b) = 0.9, phi(c) = 0.65
ANALISA REINFORCEMENT & KAPASITAS SHEARWALL

Luasan Shearwal /m2


b = 0.200 m
d = 1.000 m

Sy (axial sheawrwaal) = 1018 Ton/m2 ... (Comb Max By Program)

Sy (axial sheawrwaal) = 203.6 Ton


= 2036 kN

Global Moment (Mx) = 25.5 kN/m ... (Comb Max By Program)


K.1 K.1

B1.40X80

SHEARWALL T=20

SHEARWALL T=20
4000

LIFT

B1.40X80
K.1 K.1

6800

DENAH LIFT

B1.40X80

4000
DETAIL A

VARIASI
DETAIL A

TB 40X70

PILECAP

6800

POTONGAN - A