You are on page 1of 6

D ATA S H E E T

Nemo Intelligent Device Interface and


Nemo Device Interface Features
• Device control solutions
for 5G NR and LTE-A QoS
Nemo Intelligent Device Interface (NIDI) and Nemo Device Interface (NDI), from and QoE measurements
Keysight Technologies Inc., are revolutionary device control platforms for 5G NR • Easily expandable from a
and LTE-A QoS and QoE measurements. NIDI and NDI can be used together with single handheld unit to a
large-scale benchmarking
our drive test and benchmarking tools Nemo Outdoor, Nemo Backpack Pro (VQ system
MOS variant), and Nemo Network Benchmarking Solution (NBM) and the tests are • Support for LTE-A and 5G
run with Nemo Active Testing Application (NATA). NR devices with internal
massive MIMO antennas
The platforms offer a future-proof solution with an easy upgrade path for new • True QoE measurements
devices. With NIDI and NDI, you can perform true QoE measurements using with on-device OTT
applications
unmodified antennas of real consumer devices. The solution is easily expandable
• POLQA VQ testing over
from a single handheld unit to a large-scale benchmarking system providing analog audio with NIDI
significant CAPEX savings as the same modules and their accessories can be and NDI
reused over years, for several phone models. • POLQA VQ testing over
Bluetooth audio with NIDI
• Highly modular with a
wide range of mounting
options for all usage
scenarios
• Uniform RF and thermal
conditions for all
smartphones ensure
comparable test results
• Unique self healing
feature ensures recovery
and maximized uptime
• Support for up to 32
devices with Nemo
Outdoor
• ETSI and P3 compatible
test scripts and report
templates included

Find us at www.keysight.com Page 1


Physical
Input power
• NIDI/NDI: +12VDC nominal (10–17 V DC range), max 2.5 A
• Rooftop box: Input voltage 10–17 V DC
• Enclosure: 165 W (max), 10–17 V DC
• Example calculation with two enclosures (six NIDI/NDI units) and one PCTEL
HBFlex scanner:
- Input power: 410 W (max) (13.5V___30.5A)
- Input voltage: 10–17 V DC

Size and weight (configuration-specific)


• NIDI/NDI: 0.2 kg
• Rooftop boxes
- Thule Force XT S roofbox short: 139 cm x 89.5 cm x 39 cm; 20 kg
- Thule Motion XT XXL roofbox long: 232 cm x 95 cm x 47 cm; 26 kg
• Enclosure: 505 mm (length) x 296 mm (height) x 301 mm (width); 10.6 kg
• Example calculation:
- Empty rooftop box: 20 kg
- 2 x enclosure without UEs and NIDI/NDI units: 21.2 kg
- PCTEL HBflex scanner: 3.3 kg
- 6 x NIDI/NDI unit with UE: 2.4 kg
- Total: 46.90 kg

Operating temperature range


• NIDI/NDI: 0°C–+55°C
• Enclosure: -40°C–+45°C
• UE: Check from the device vendor

Communications interface
• USB

Connectors
• IP65 rated quick-release connectors

Attenuation
• Independently validated free space attenuation less than +/- 1.5dB over 800-
2600MHz

Find us at www.keysight.com Page 2


Main Hardware Modules
NIDI/NDI
• NIDI/NDI unit
• Smartphone adapters with quick release

Standard Accessories
• USB data cable for host (PC)
• USB data cable for smartphone
• Quick guides

Optional Accessories and Modules


Enclosure
• Thermal enclosure for four NIDI/NDI units
• The enclosure ensures that the test phones stay in ideal temperature and connected
to 5G NR while performing long-term measurements, such as high-speed file
downloads or streaming tests

Rooftop box
• Thule Force XT S roofbox short
- Mounting plate for two enclosures
• Thule Motion XT XXL roofbox long
- Mounting plate for up to six enclosures
• Active ventilation with delayed shut-off

Window mounting kit


• For mounting NIDI/NDI units on a vehicle window
• Attached to the vehicle window with two suction cups
• Accommodates 1–4 NIDI/NDI units

Table mounting kit


• For mounting NIDI/NDI units on a flat surface
• Accommodates 1–4 NIDI/NDI units

Find us at www.keysight.com Page 3


Conformance
NIDI/NDI complies with the following applicable European Directives:

• Low Voltage Directive 2014/35/EU


• EMC Directive 2014/30/EU
• RoHS Directive 2011/65/EU

and conforms with the following product standards:

EMC

Standard Limit

IEC 61326-1:2012 / EN 61326-1:2013

CISPR 11:2009+A1:2010 / EN Group 1 Class A


55011:2009+A1:2010

IEC 61000-4-2:2008 / EN 61000-4- 4 kV CD, 8 kV AD (Optional: 6 kV CD, 15 kV AD)


2:2009

IEC 61000-4-3:2006+A1:2007 3 V/m 80 MHz – 2 GHz 1 V/m 2-2.7 GHz


+A2:2010 / EN 61000-4-3:2006
+A1:2008+A2:2010

IEC 61000-4-4:2004+A1:2010 / EN 0.5 kV signal lines, 1 kV power lines


61000-4-4:2004+A1:2010 (optional: 1 kV signal lines, 2 kV power lines)

IEC 61000-4-5:2005/ EN 61000-4- 0.5 kV line-line, 1 kV line-ground, 1 kV signal lines


5:2006 (optional: 1 kV signal lines, 2 kV power lines)

IEC 61000-4-6:2008 / EN 61000-4- 3V, 0.15 – 80 MHz


6:2009

IEC 61000-4-8:2009 / EN 61000-4- 3 A/m; 50Hz, 60Hz


8:2010

IEC 61000-4-11:2004 / EN 61000-4- 0 % for 1/0.5 (0º, 180º) cycle, 0 % for 250 / 300 cycles, 70 % for
11:2004 25 / 30 cycles

CISPR 25 30MHz-1GHz

ISO 7637-2:2011 Pulse 1, 2A, 2B, 3A, 3B and 4

EN 300 328 Radiated emissions

EN 301 489-1, EN 301 489-17 30 MHz – 6 GHz, 3 V/m

Find us at www.keysight.com Page 4


Shock and vibration

Standard Limit

Random vibration, IEC/EN 60068-2-64 Random vibration (operational)

Frequency (Hz) Slope (dB/Octave) PSD g2/Hz

5-350 0 0.0002

350-500 -6 --

500 -- 0.0001

Value of area under the integrated curve: ~0.30 grms


Duration: 10 minutes/axis

Random vibration, IEC/EN 60068-2-64 Random vibration (survival)

Frequency (Hz) Slope (dB/Octave) PSD g2/Hz

5-100 0 0.020

100-137 -6 --

137-350 0 0.0107

350-500 -6 --

500 -- 0.0052

Value of area under the integrated curve: ~2.41 grms


Duration: 10 minutes/axis

Sinusoidal, IEC/EN 60068-2-6 Swept sine (survival)


0.75 g, 5-500-5 Hz Resonant Search, 1 Octave/Minute Sweep
Rate, Resonant Dwell 10 minutes

Shock, IEC/EN 60068-2-27 Shock, End Use and Handling Environment


Powered ON
3m/s minimum velocity change
1 shock/side (6 shocks in total), half sine

Shock, IEC/EN 60068-2-27 Shock, Transportation Environment


Powered OFF
8.0 m/s minimum velocity change
30g minimum acceleration
1 shock/side (6 shocks in total), trapezoidal
In shipping container

Find us at www.keysight.com Page 5


Environmental

Standard Limit

Temperature Performance Tests, IEC/ Low Temperature (-5C), Operating, Power On, 4h
EN 60068-2-1, IEC/EN 60068-2-2 Low Temperature (-40C), Storage Survival, Power Off, 4h
Low Temperature (-5C), Operating, Start-up, Power-on, 4h
High Temperature (60C), Operating, Power On, 4h
High Temperature (70C), Storage Survival, Power Off, 4h
High Temperature (60C), Operating, Start-up, Power-on, 24h
Ambient Temperature (25C), Operating, 24h

Damp heat cyclic, IEC/EN 60068-2-30 +25…+40 °C, 50-98 %RH


(5x24 hours)

Safety

Standard Limit

IEC 61010-1:2010 / EN 61010-1:2010

ISO/PAS 11154:2006(E) Safety


requirements for roof load carriers

RoHS

Standard Limit

EN 50581:2012

Learn more at: www.keysight.com


For more information on Keysight Technologies’ products, applications or services,
please contact your local Keysight office. The complete list is available at:
www.keysight.com/find/contactus

Find us at www.keysight.com Page 6


This information is subject to change without notice. © Keysight Technologies, 2021, Published in USA, October 5, 2021, 3121-1326.EN

You might also like