D100/D200 Desktop Series Fingerprint Employee Time Clock Operation Guide V1.

Product Appearance Menu List Set Time:


5
1 1. LCD
Press [OK] key about 3 seconds to turn on the device, press [M] key IN MENU
User
▼ Setup System
Dev ID 10000
▼ Time
00-00-0000
MON
00:00
Time
11-10-2010
THU
15:30
09 : 00
System
[M] [OK] [OK] [C]
to enter the system menu. Menu list: 26 [OK]
6 Setup Log Setup Time ↑ Save?
System Info Language ENG Set-C Next-OK No-C Yes-OK
2.State Key(Clock Out) 10-11-17 WED Hardware Test

Select [Setup] Select [System] Select [Time] Modify system time Press [OK] to save
2 Page Down Dev ID
7 Enroll
3.State Key(Clock In) Time
Other Setup
Fingerprint Employee Time Clock

Delete
3
8 Page Up User Language
Verify Mode
M→[User]→[OK]→[Verify Mode]→[OK]→[OK]→Input employee ID→[OK]→ M→[Setup]→[OK]→[System]→[OK]→[Language]→[OK]→
Workcode Scope
4 9 4.0-9 Num. Key Admin Setup Use [IN/ ]/[OUT/ ] to select ‘ANY/PW+FP/ID+FP’→[OK]→[OK]. Use [IN/ ]/[OUT/ ] to select ENG/FRCH/GERM/...→[OK]→[C]→[OK].
Daylight Saving
10 5.LED Admin Clear Item Explanation
Precision Item Explanation
System Language Optional 4 languages.
Volume Any Fingerprint only, Card only or ID+Password only
5 Auto Off It requires both Password and Fingerprint verification Factory default
1 PW+FP setting Related Language
Auto Update together
6
Setup Image Disp. ID+FP Enter the user ID first, then verify the fingerprint
2 7
Precision, Volume, Auto off, Auto Update, Image Disp., Log Alert, Re-Verify.
Log Alert Factory default
Fingerprint Employee Time Clock
Log Setup Any Explanation
setting Item
3 Re-Verify
8
Set terminal fingerprint matching precision.
Hardware Test Keypad, LCD, Voice, Sensor, Flash Precision
M→[Setup]→[OK]→[System]→[OK]→[Dev ID]→[OK]→ 0-[Normal],1-[Good], 2-[Exact].
4 9
Dev ID: Input the device’s ID→[OK]→[C]→[OK].
Set the terminal voice volume.
10 System Info
Item Explanation Volume 0-[mute], 5-[Max].

Device ID of the unit which is required in software Set the time duration for an idle clock to go into sleep
1-99999999 Auto off
mode.No-[Not Off], 250min-[Max Time].
Illustration for placing finger Factory default
communication
1 Auto update means the previous lower quality fingerprint
setting Auto Update template will be automatically replaced by the new higher
Correct method (Place you finger flat on the sensor to insure maximum sensor coverage ): quality one during fingerprint verification.
M→ [Setup]→[OK]→[System]→[OK]→[WorkCode Scope]→[OK]
WorkCode: →Input Max→[OK]→Input Min→[OK] →[C]→[OK]. Choose to display the fingerprint on the screen during the
Image Disp. verification process. [Yes] - show fingerprint image,
Item Explanation [No] - not show fingerprint image
The terminal will alarm when the memory capacity
Place finger in the center of the sensor. Finger must remain flat and motionless 0-999999 Valid scope for the Workcode Log Alert is less than the [Log Alert] value.[No]-Not alarm,
during enrollment and verification.
Factory default Max 999999 Max. value 5,000.
Incorrect method:
setting Min 0 The duration of time in which the terminal will ignore
Tips: WorkCode indicates the work type,easily distinguishes which Re-Verify repeated attempts for authentication.
attendance record is related to which work type. [No]: Disable the function; Max. value is 250 min.

Moving finger before the


backlight of sensor is off.
Improper finger placement
on the sensor.
Finger placed on
sensor at an angle.
Removing finger from the sensor
during enrollment or verification process.
Using the fingertip only. Moving finger during the process
of enrollment or verification.
Wiring Diagram
Operation Guide
Enroll User: Each user can register two fingerprints and one password .

IN MENU User ▼ Enroll

09 : 00
User Enroll
[M] [OK] [OK]
26 Setup Delete ID 008101
10-11-17 WED System Info Verify Mode Esc-C Set-OK (ID number range:0-999999)
Select [User] Select [Enroll] Input user ID

Enroll Fingerprint: Place the same finger on the sensor twice to enroll fingerprints.
Enroll Enroll FP Enroll FP Enroll FP
FP 1/2
[OK] [OK]
Password Place Finger #1 Place Finger #2 008101-1
Esc-C Set-OK Sav-OK

Select [FP] Enroll fingerprint Press [OK] to save


RJ11
Enroll Password: Password length: 0-999999.
PC USB Port
Enroll Enroll PWD Enroll PWD Enroll PWD
FP 1/2
[OK] [OK] [OK] PWD ID ****** [OK]
Password PWD ID ****** 008101-P
Esc-C Set-OK Esc-C Set-OK Confm ****** Cancel-C Sav-OK

Select [Password] Input password Input password again Press [OK] to save

Admin Setup: Admin(Administrator) has full access permissions to the device. It is recommended to assign a minimum of two administrators to each unit.

IN MENU User ▼ Admin Setup Admin Setup Admin Setup Admin Setup
Admin Setup ID 008101
09 : 00
User
[M] [OK] [OK] [OK] [OK] [OK]
26 Setup Admin Clear ID 000000 008101
10-11-17 WED System Info Esc-C Add-OK No-C Yes-OK Esc-C Add-OK

Select [User] Selelct [Admin Setup] Input Admin ID Setup successful

The products are subject to change without notice.