MS2108

DIGITAL CLAMP METER


OPERATION MANUAL

600V CAT.lll OFF


MAX 600A A
MS2108

SEL
OFF

B.L
Hz/%
MIN
MAX RAN HOLD

Press 2 Sec
T-RMS
AUTO-PWER OFF

AC/DC CLAMP METER INRUSH

AUTO MANU MAX MIN ZERO

°C°F%
μmVA
nμmF

MkΩ
Hz

TRMS INRUSH

COM INPUT

600V
CAT. III
MAX 600V
CONTENTS CONTENTS
1. Safety Information............................1 4.7 Auto Power Off..........................................18
1.1 Preliminary............................................1 4.8 Preparing For Measurement ......................19
. ... ...................................2
1.2 During use .....
1.3 Symbols................................................3 4.9 Measuring Ac Current ...............................20
1.4 Maintenance............ .............................4 4.10 Measuring Inrush Current ........................22
4.11 Measuring Dc Current ..............................24
2. Description....................................... 4
4.12 Measuring Ac Voltage ..............................26
2.1 Names OF Parts....................................6
4.13 Measuring Dc Voltage..............................27
2.2 Switch, Buttons And Input Jacks............7
4.14 Measuring Frequency ..............................30
2.3 Names OF Parts ..................................7
4.15 Measuring Duty .......................................34
3. Specifications..................................11 4.16 Measuring Resistance .............................38
4.17 Testing Diode ..........................................40
3.1 General Specifications ........................11
3.2 Technical Specifications ......................12 4.18 Testing Continuity....................................42
4.19 Measuring Capacitance ...........................44
4. Operation Instruction.......................15
4.1 Holding Readings .................................15 5. Maintenance.......................................46
4.2 Switching Ranges.................................15 5.1 Replacing The Batteries.............................46
4.3 Switching Frequency Or Duty ................16 5.2 Replacing Test Leads.................................46
4.4 Switching Maximum Or
6. Accessories.......................................46
Minimum Value....................................16
4.5 Switching Functions..............................17
4.6 Back Light And Clamp Lighting Bulb.......17
1. Safety Information 1.1.4 Test leads must be kept in good condition.
Before using check whether the insulation
WARNING on test leads has been damaged and any
BE EXTREMELY CAREFUL WHEN USING THIS wire has been exposed.
METER. Improper use of this device can result 1.1.5 Use the test leads supplied to ensure operation
in electric shock or destruction of the meter. safety. If required, they must be replaced with
Take all normal safety precautions and follow test leads of the same model or class.
the safeguards suggested in this manual. To 1.2 During Use
exploit full functionality of the meter and 1.2.1 Use the right input jack, function and range.
ensure safe operation, please read carefully 1.2.2 Do not take measurements that exceed the
and follow the directions in this manual. protection limit values indicated in the
specifications.
This meter has been designed according to IEC-1010 1.2.3 Do not touch the metal tips of the test leads
concerning electronic measuring instruments with an when the meter is connected to the circuit to
overvoltage category CAT 600V and pollution 2. be measured.
Follow all safety and operating instructions to ensure 1.2.4 Keep your fingers behind the probe barriers
safe use of the meter. when taking a measurement with an effective
With proper use and care, this digital multimeter will voltage above 60V DC or 30V rms AC.
1.2.5 Do not take voltage measurement if the value
give you years of satisfactory service. between the terminals and earth ground
1.1 Preliminary exceeds 600V.
1.2.6 Select the highest range if the value scale to be
1.1.1 When using the meter, the user must observe all measured in the manual range is unknown.
normal safety rules concerning: 1.2.7 Disconnect the test leads from the circuit under
- General protection against electric shock test before turning the rotary selector to change
- Protection of the meter against misuse. functions.
1.1.2 When the meter is delivered, check whether it 1.2.8 Do not measure the resistance,capacitance,
has been damaged in transit. diode or continuity of live circuits.
1.1.3 After being stored and delivered under harsh 1.2.9 Do not connect the meter to any voltage source
conditions, the meter should be checked and while the rotary selector is in the current,
confirmed whether any damages have been resistance, capacitance, diode or continuity range.
incurred. 1.2.10 Do not take capacitance measurements until
the capacitor to be measured has been fully
discharged.

01 02
1.2.11 Do not use the meter near explosive gases, opening the rear case and battery cover of the meter.
steam or dirt. 1.4.3 To avoid any electric shock caused by error
1.2.12 Stop using the meter if any abnormalities or readings, replace the batteries immediately when
faults are observed. the “ ” sign appears on the display.
1.2.13 Do not use the meter unless its rear case and 1.4.4 Use damp cloth and mild detergent to clean the
battery cover is securely fastened in its original meter; do not use abrasives or solvents.
position. 1.4.5 Turn the rotary selector to OFF position to switch
1.2.14 Do not store or use the meter in areas exposed off the power when the meter is not in use.
to direct sunlight, at high temperature or with 1.4.6 Remove the batteries to avoid damages to the
high relative humidity. meter if it will idle for a long time.
1.3 Symbols 2. Description
- This meter is a portable professional measuring instrument
Caution, risk of danger (Important safety with LCD and back light easily reading. The 'single-hand
information; refer to the operation manual.) operation' design for the range switch makes measurement
Application around and removal from HAZARDOUS simple and easy. Overload protection and low battery
LIVE conductors is permitted. indication are provided. It is an ideal multi-function
Instrument with scores of practical applications for
Double insulation(Protection class II). professional, workshop, school, hobby and home use.
CAT III Overvoltage (Installation) category III, Pollution - The meter can perform measurements of AC/DC voltage
Degree 2 per IEC1010-1 refers to the level of and current, resistance, frequency, duty, capacitance, as
Impulse Withstand Voltage protection provided. well as continuity and diode test.
- Both auto range and manual range are available.
Conforms to European Union Directive - This meter is equipped with reading hold function.
- This meter is equipped with true root mean square value
Earth (ground) terminal measuring function (at AC A and AC V range).
1.4 Maintenance - This meter is equipped with inrush current measuring
function.
1.4.1 Do not attempt to remove the rear case to adjust - This meter is equipped with auto zero function
or repair the meter. Such actions should only be (at DCA range).
performed by a technician who fully understands - This meter is equipped with maximum value measuring
the meter and the danger involved. function.
1.4.2 Before opening the case and battery cover of the - This meter is equipped with minimum value measuring
meter, always disconnect test leads from all function.
sources of electric current. Disconnect the test - This meter can measure frequency by clamp.
- This meter has function of auto power off.
leads from all sources of electric current before
03 04
2.1 Names Of Components
(1) Current Clamp
(2) Clamp Lighting Bulb
(3) Panel 1
(4) Trigger
(5) Function Switch Button (S E L) 2
(6) MAX/MIN Switch Button (MAX/MIN) 15
(7) Auto/Manual Switch Button (RAN) 3
(8) Liquid Crystal Display (LCD) 14
(9) COM Jack 4 600V CAT.lll
MAX 600A
MS2108
A
OFF

(10) Input Jack A

(11) Hz/Duty Switch Button (Hz/%) 13


5 V

(12) Reading Hold/Back Light Button (HOLD/B.L) Ω

(13) Rotary selector 6 SEL


OFF

(14) OFF - power switch MIN


Hz/%
B.L
MAX RAN HOLD
(15) “+” Symbol Press 2 Sec
12
(16) “-” Symbol
T-RMS

7 AC/DC CLAMP METER


AUTO-PWER OFF

INRUSH
16
(17) Rear Case AUTO MANU MAX MIN ZERO

°C°F%
μmVA
11
(18) Fixing Screw of Battery Cover 8 nμmF

MkΩ
Hz
17
(19) Battery Cover
TRMS INRUSH

COM INPUT 10 CAUTION


ACCORD WITH

9 600V 18
POLLUTION DEGREE 2
6000V CAT lll
IEC1010 &1 IEC1010 2 032
CAT. III
MAX 600V

19
WARNING
TO AVOID ELECTRICAL
SHOCK DO NOT
OPERATE WITH OPEN
BATTERY COVER

DC1.5VX3, SIZE AAA

PLEASE READ
MANUAL FOR SAFETY

PATENT PENDING

05 06
2.2 Switch, Buttons And Input Jacks AC Alternating current
HOLD/B.L Button DC
- For holding the reading or control backlight Direct current
S E L Button Diode test
- For switching among measuring functions
RAN Button Continuity buzzer
- For switching between auto and manual ranges. AUTO Auto range mode
Hz/% Button
- For switching between frequency and duty measuring MANU Manual range mode
functions.
MAX/MIN Button MAX The maximum value is being measured.
- For switching between maximum and minimum value MIN The minimum value is being measured.
measuring function.
Rotary Selector ZERO DCA zero
- For selecting functions and ranges. Aotu power off
OFF Position
- for turning off the power. Battery low
INPUT Jack TRMS True RMS
- For measuring voltage, resistance, frequency, duty,
capacitance, diode, and continuity. This indicates that the display data is
COM Jack H being held.
- Common input connection for current, voltage, resistance,
frequency, duty, capacitance, diode, continuity INRUSH Inrush current is being measured.
measurement.
Clamp % Percent (Duty cycle)
- For measuring current mV, V Milli-volts, Volts (Voltage)
2.3 LCD (Liquid-crystal display)
A Amperes (Current)
AUTO MANU MAX MIN ZERO
μF, mF Micro-farad, Milli-farad (Capacitance)
°C°F%
Ω, kΩ, Ohms, Kilo-ohms, Mega-ohms
μmVA
nμmF MΩ (Resistance)
MkΩ
Hz Hz, kHz Hertz, Kilo-hertz (Frequency)
TRMS INRUSH

07 08
3. Specifications 3.2.1.2 Both sinusoidal and non-sinusoidal waveforms
can be tested by True RMS Clamp Meter exactly.
Calibration is required once a year, to be carried out at At AC A & AC V ranges, even short two test probes
a temperature between 18°C and 28°C (64°F to 82°F) there are stil l 1-50 digits might be displayed on
and relative humidity below 75%. LCD. This is normal. Test result will not be affected.
3.1 General Specifications 3.2.1.3 At AC A and AC V range, True RMS value can be
3.1.1 Auto range and manual range options are available. tested only when input signal is more than 2% of
3.1.2 Over range protection is provided for all ranges. full range.
3.1.3 Maximum voltage between terminals and earth 3.2.1.4 To ensure the precision of test result, input signal
ground: 600V DC or rms AC should be:
3.1.4 Operating altitude: max. 2000 meters (7000 ft.) AC voltage: > 13 mV
3.1.5 Display: LCD AC current: > 1.3A
3.1.6 Maximum value display: 6599 digits 3.2.2 AC Current
3.1.7 Polarity indication: automatic; ‘-’ for negative
polarity. Range Resolution Accuracy
3.1.8 Over range indication: ‘0L’ or ‘-0L’
66A 0.01A ±(3.0% of rdg + 10 digits)
3.1.9 Sampling Time: approx. 0.4 second per sample
3.1.10 Unit indication: function and unit. 600A 0.1A
3.1.11 Auto power off time: 30 min.
3.1.12 Operating power : 1.5V×3 AAA batteries - Max. input current: 600A
3.1.13 Battery low indication: ‘ ’ on LCD - Frequency range: 40 to 400Hz
3.1.14 Temperature factor: < 0.1×Accuracy /°C - Response: true root mean square value
3.1.15 Operating temperature: 0°C to 40°C(32°F to 104°F) 3.2.3 Inrush Current
3.1.16 Storage temperature: -10°C to 50°C(10°F to 122°F)
3.1.17 Dimension: 208×78×35mm Range Resolution Accuracy
3.1.18 Weight: approximate 340g(including batteries) <60A take it only as referance
66A 0.01A
3.2 Electrical Specifications
Ambient temperature: 23±5°C Relative humidity: < 75% 600A 0.1A ±(10.0% of rdg + 60 digits)
3.2.1 TRUE RMS - Integration Time: 100ms
3.2.1.1 For measuring non-sinusoidal waveforms, test - Measurement range: 30 ~ 600A
error which is occurred by using True RMS - Max. input current: 600A
measurement techniques is less than by using - Frequency range: 40 to 400Hz
traditional average-reading techniques. - Response: true root mean square value

09 10
3.2.4 DC Current 3.2.6 AC Voltage
Range Resolution Accuracy Range Resolution Accuracy

66A 0.01A ±(3.0% of rdg + 10 digits) 660mV 0.1mV ±(1.5% of rdg + 10digits)

600A 0.1A 6.6V 0.001V ±(1.2% of rdg + 5digits)

- Max. input current: 600A DC 66V 0.01V


3.2.5 DC Voltage 600V 0.1V ±(1.5% of rdg + 10digits)
Range Resolution Accuracy - Input impedance: 10MΩ
- Overload protection: 660mV range: 250V DC or
660mV 0.1mV rms AC, 66V-600V ranges: 600V DC or 600V rms AC.
6.6V 0.001V ±(0.8% of rdg + 3digits) - Max. input voltage: 600V rms AC
- Frequency range: 40 to 400Hz
66V 0.01V - Response: true root mean square value
600V 0.1V ±(1.0% of rdg + 5digits) Note:
At small voltage range, unsteady readings will appear
- Input impedance: 10MΩ before the test leads contact the circuit. This is normal
- Overload protection: 660mV range: 250V DC or rms because the meter is highly sensitive. When the test
AC, 6.6V-600V ranges: 600V DC or 600V rms AC. leads contact the circuit, the true reading will be shown.
- Max. input voltage: 600V DC 3.2.7 Frequency
Note: 3.2.7.1 By A range ( from current clamp):
At small voltage range, unsteady readings will appear Range Resolution Accuracy
before the test leads contact the circuit. This is normal
because the meter is highly sensitive. When the test 660Hz 0.1Hz
leads contact the circuit, the true reading will be shown. ±(1.5% of rdg + 5 digits)
1kHz 0.0011Hz
>1kHz 0.0011Hz Take it only as referance
- Measurement range: 10 ~ 1kHz
- Input current range: >1A rms AC (higher input
current at higher frequency)
- Max. Input current: 600A rms AC

11 12
3.2.7.2 By V range: 3.2.9 Resistance
Range Resolution Accuracy Range Accuracy
Resolution
660Hz 0.1Hz 660Ω 0.1Ω
6.6kHz 0.001kHz ±(1.5% of rdg + 5 digits)
6.6kΩ 0.001kΩ
10kHz 0.01kHz 66KΩ 0.01kΩ ±(1.2% of rdg + 2digits)
>10kHz 0.01kHz Take it only as referance
660kΩ 0.1kΩ
- Measurement range: 10 ~ 10kHz 6.6MΩ 0.001MkΩ
- Input voltage range: > 0.2V rms AC (higher input
voltage at higher frequency) 66MΩ 0.1MΩ ±(2.0% of rdg + 5digits)
- Input impedance: 10M Ω
- Max. input voltage: 600V rms AC - Open circuit voltage: 0.4V
- Overload protection: 250V DC or rms AC
3.2.8 Duty Cycle 3.2.10 Diode
Range Resolution Accuracy
Range Resolution Function
10 - 95% 0.1% ±3.0%
displaying approximate
0.001V for ward voltage of diode
3.2.8.1 By A range ( from current clamp):
- Frequency response: 10 ~1kHz
- Input current range:>1A rms AC (higher input current - Forward DC current~1mA
at higher frequency) - Reversed DC voltage~3.3V
- Max. input current: 600A - Overload protection: 250V DC or rms AC
3.2.8.2 By V range: 3.2.11 Continuity
- Frequency response: 10 ~ 10 kHz
- Input voltage range:>0.2V rms AC (higher input Range Resolution Function
voltage at higher frequency) Built-in buzzer will sound,
- Input impedance: 10M Ω 0.1Ω if resistance is lower than
- Max. input voltage: 600V rms AC 30.
- Open circuit voltage~1.2V
- Overload protection: 250V DC or rms AC

13 14
3.2.12 Capacitance Note:
Range Resolution Accuracy At frequency range, meter can't be set to manual range
mode.
6.6µF 0.001µF <2µF±( 4.0% of rdg + 50digits)
4.3 Switching Frequency Or Duty
66µF 0.01µF 4.3.1 During working at the voltage or current ranges,
660µF 0.1µF ±(4.0% of rdg + 3 digits) press the “Hz/%” button one time, frequency of
the voltage or current will be measured.Press the
6.6mF 0.001mF “Hz/%” button twice, the meter will be changed
into the duty range for measuring the duty cycle
66mF 0.01mF of the voltage or current. At the same time, the
meter is changed into manual mode.
- Overload protection: 250V DC or rms AC
4.3.2 Press the “ Hz/% ” button again, meter will be
4. Operation Instruction back to the condition of the voltage or current
4.1 Holding Readings measuring.
4.1.1 Press the “HOLD/B.L” button to hold the readings Note:
while taking measurement and the value on the During working at maximum or minimum value
display will be held. measuring function, the meter can't be changed into
4.1.2 Press the “HOLD/B.L” button again to release frequency or duty cycle measuring mode.
the reading hold function.
4.2 Switching Ranges 4.4 Switching Maximum Or Minimum Value
4.2.1 When the meter is turned on, it is at the auto 4.4.1 At all ranges, press the "MAX/MIN" button one
range mode for measuring current, voltage, time, the meter can be set to maximum value
resistance, capacitance and frequency. measuring mode; press the button three times,
4.2.2 Press the"RAN" button for manual range mode. the meter will get back to normal test mode,
The range will go up one level at each press and and the maximum and minimum value will be
return to the lowest level when the highest level recorded by the chip.
is reached. 4.4.2 Press the ”MAX/MIN” button more than one
4.2.3 Press the "RAN" button for one or more seconds second or press the“RAN” button, the meter
to return to the auto range. will get back to normal test.
4.2.4 Press the “RAN” button to get back to normal
test during working in maximum or minimum
value measuring function,

15 16
Note: 4.6.2 During the back light is working, press the
1) During measuring maximum or minimum value, the “HOLD/B.L” button for two or more seconds, it
meter will be set to manual mode automatically. will be turned off.
2) During working at frequency or duty measuring 4.6.3 At the current range, when the back light is
function, the meter can't be changed into maximum switched on, the clamp lighting bulb will be turned
or minimum value measuring mode. on at the same time.
4.5 Switching Functions Note:
4.5.1 AC A range - LED, which requires a larger working current, is the
4.5.1.1 Press the “SEL” button, the meter will get main source of back light. Although the meter is
into inrush current test mode. equipped with a timer set at 60 seconds (i.e. the back
4.5.1.2 If press the “SEL” button again, the meter light will be off automatically after 60 seconds),
will get into inrush current test mode again. frequent use of the back light will shorten the life of
4.5.1.3 Press the “SEL” button more than one second the batteries. Therefore, do not use the back light
or press the “ RAN ” button, the meter will get unless necessary.
back to normal test mode. - When the battery voltage is<3.7V, the symbol “ ”
4.5.2 DC A range (battery low)will appear on the LCD. When the back
4.5.2.1 Press the “ SEL ” button, the meter will get light is on, even if the batter is>3.7V, the “ ” may
into zero. appear because of its large working current which
4.5.2.2 If press the “SEL” button again, the meter will cause the voltage to drop. (The accuracy
will get into zero again. of the measurement cannot be assured when the
4.5.2.3 Press the “ SEL” button more than one “ “ symbol appears.) In this case, you need not
second or press the “ RAN ” button, the meter replace the batteries yet. Normally, the batteries
will get back to the normal test mode. can last until the “ ” appears when the back light
4.5.3 Press the “SEL” button to switch between AC is not being used.
and DC measurement at the voltage ranges. 4.7 Auto Power Off
4.5.4 Press the ” SEL ” button to switch among 4.7.1 If there is no any operation within any thirty
resistance, diode and continuity ranges. minutes after power is on, meter will auto power
4.6 Back Light And Clamp Lighting Bulb off.
4.7.2 After auto power off, if press the “SEL” button,
4.6.1 Press the “ HOLD/B.L” button for two or more
meter will recover the working condition.
seconds to switch on the back light if the light
in the environment is too dim for taking reading,
which will last for 60 seconds.
17 18
4.7.3 Press both power on switch and one of 4.9 Measuring AC Current
”MAX/MIN” or “RAM”or “Hz/%”button at the
same time more than one second for exiting WARNING
auto power off function. Beware of Electrocution.
Ensure that the test leads are disconnected
4.8 Preparating For Measurement from the meter before making current clamp
4.8.1 Switch on the power by turning the rotary selector. measurements.
If the battery voltage is lower than 3.7V, the “ ”
symbol will appear and the batteries should be 4.9.1 Set the rotary selector to the A range position.
replaced. 4.9.2 Auto range mode or manual range mode can
4.8.2 The “ ” symbol shows that the input voltage or be selected by pressing the“RAN”button.
4.9.3 Press the trigger to open jaw. Fully enclose
current should not exceed the specified value in only one conductor.
order to protect the internal circuit from damage. 4.9.4 Take the reading on the LCD.
4.8.3 Turn the rotary selector to the required function
and range to be measured. Under the manual Note:
mode, choose the highest range when the value 1) Do not put more than one cable into
scale to be measured is unknown. the jaw during test, otherwise incorrect
4.8.4 Connect the common test lead first and then the test value might be obtained.
charged test leads when making connection. 2) For optimum results, center the conductor in the jaw.
Take away the charged test lead first when 3) At the manual range mode, when only ‘O L’ is shown
disconnecting. on the LCD, it means the measurement has
exceeded the range. A higher range should
be selected.
4) Under the manual range mode, when the scale of
the value to be measured is unknown beforehand,
set the range to the highest.
5) “ ” means the maximum input current is
600A rms AC.

19 20
4.10 Measuring Inrush Current
WARNING
Beware of Electrocution.
Ensure that the test leads are disconnected
from the meter before making current clamp
measurements.
4.10.1 Set the rotary selector to the A range position.
4.10.2 Press the trigger to open jaw. Fully enclose
only one conductor.
4.10.3 Press the “SEL” to enter the INRUSH current
measurement mode. Then LCD displays
“ - - - - ” until the motor starting up and being
detected. The detection will be done only one
A
OFF
A
OFF
time and the output reading will be hold.
A A 4.10.4 Take the reading on the LCD.
V V Note:
Ω Ω 1) Do not put more than one cable into
SEL
OFF
SEL
OFF
the jaw during test, otherwise incorrect
MIN B.L MIN B.L
test value might be obtained.
RAN Hz/% HOLD RAN Hz/% HOLD
MAX MAX
2) For optimum results, center the conductor in the jaw.
3) At the manual range mode, when only ‘O L’ is shown
INRUSH DIGITAL INRUSH DIGITAL
AUTO MANU MAX MIN
CLAMP

ZERO AUTO MANU MAX MIN


CLAMP

ZERO
on the LCD, it means the measurement has
°C°F%
μmVA
nμmF
°C°F%
μmVA
nμmF
exceeded the range. A higher range should
TRMS INRUSH
MkΩ
Hz

TRMS INRUSH
MkΩ
Hz
be selected.
COM INPUT COM INPUT
4) Under the manual range mode, when the scale of
the value to be measured is unknown beforehand,
600V
CAT. III
MAX 600V
600V
CAT. III
MAX 600V
set the range to the highest.
5) “ ” means the maximum input current is
600A rms AC.

21 22
4.11 Measuring DC Current
WARNING
Beware of Electrocution.
Ensure that the test leads are disconnected
from the meter before making current clamp
measurements.
4.11.1 Set the rotary selector to the A range position.
4.11.2 Auto range mode or manual range mode can be
selected by pressing the “RAN” button.
4.11.3 Press the “SEL” button, the meter will be set
to zero.
4.11.4 Press the trigger to open jaw. Fully enclose only
one conductor.
OFF OFF
4.11.5 Take the reading on the LCD.
A A
4.11.6 Symbol “-” will be displayed on LCD if the
A A
direction of the current is negative.
V V
Note:
Ω Ω

SEL SEL
1) Do not put more than one cable into the jaw during
OFF OFF
test, otherwise incorrect test value might be
MIN
MAX RAN Hz/% B.L
HOLD
MIN
MAX RAN Hz/% B.L
HOLD
obtained.
2) For optimum results, press the “SEL” button to
INRUSH DIGITAL CLAMP INRUSH DIGITAL CLAMP
make the meter get into zero first.
AUTO MANU MAX MIN ZERO AUTO MANU MAX MIN ZERO 3) For optimum results, center the conductor in the jaw.
°C°F%
μmVA
nμmF
°C°F%
μmVA
nμmF
4) At the manual range mode, when only 'O L' or '-O L'
TRMS INRUSH
MkΩ
Hz

TRMS INRUSH
MkΩ
Hz
is shown on the LCD, it means the measurement
has exceeded the range. A higher range should
COM INPUT COM INPUT
be selected.
600V
CAT. III
600V
CAT. III
5) Under the manual range mode, when the scale
MAX 600V MAX 600V

of the value to be measured is unknown beforehand,


set the range to the highest.
Correct Incorrect 6) “ ”means the maximum input current is 600A DC.

23 24
4.12 Measuring AC Voltage
WARNING
Beware of Electrocution.
Pay special attention to avoid electric shock
when measuring high voltage.
Do not input the voltage which more than
600V rms AC.
4.12.1 Plug the black test lead into the COM jack and
the red test lead into the INPUT jack.
4.12.2 Set the rotary selector to V position to make
the meter get into AC V range.
4.12.3 Auto range mode or manual range mode can
A
OFF
A
OFF be selected by pressing the “RAN” button.
A A
4.12.4 Connect the test leads to the voltage source or
load terminals for measurement.
V V
4.12.5 Take the reading on the LCD.
Ω Ω

SEL SEL
Note:
OFF OFF

MIN B.L MIN B.L


1) At small voltage range, unsteady readings may
MAX RAN Hz/% HOLD MAX RAN Hz/% HOLD appear before the test leads contact the circuit.
This is normal because the meter is highly sensitive.
INRUSH DIGITAL CLAMP INRUSH DIGITAL CLAMP When the test leads contact the circuit, the true
AUTO MANU MAX MIN ZERO

°C°F%
AUTO MANU MAX MIN ZERO

°C°F%
reading will be shown.
μmVA
nμmF

MkΩ
μmVA
nμmF

MkΩ
2) At the manual range mode, when only 'OL' is shown
TRMS INRUSH
Hz

TRMS INRUSH
Hz

on the LCD, it means the measurement has exceeded


COM INPUT COM INPUT
the range. A higher range should be selected.
3) At the manual range mode, when the scale of the
600V
CAT. III
MAX 600V
600V
CAT. III
MAX 600V
value to be measured is unknown beforehand, select
the highest range first and lower the range gradually.
4) “ ” means the maximum input voltage is 600V rms AC.
Correct Incorrect 5) If the test result is more than 610V rms AC, symbol
“OL” will be displayed on LCD and the build-up
buzzer will sound.

25 26
4.13.1 Plug the black test lead into the COM jack and
the red test lead into the INPUT jack.
4.13.2 Set the rotary selector to at the V range position.
4.13.3 Press the“SEL” button to turn to DC V range.
Auto range mode or manual range mode can be
selected by pressing the “RAN” button.
4.13.4 Connect the test leads to the voltage source or
load terminals for measurement.
4.13.5 Take the reading on the LCD. The polarity
symbol denotes the polarity of the end
MIN 600A
CAT III 600V
A
OFF connected by the red test lead.
A
Note:
V
1) At small voltage range, unsteady readings will

appear before the test leads contact the circuit.
SEL
OFF
This is normal because the meter is highly sensitive.
B.L
MIN
MAX RAN Hz/% HOLD When the test leads contact the circuit, the true
reading will be shown.
INRUSH DIGITAL CLAMP
AUTO MANU MAX MIN ZERO
2) Under the manual range mode, when only
°C°F%
μmVA
nμmF
‘O L ’ o r ‘- O L’ is shown on the LCD, it means the
TRMS INRUSH
MkΩ
Hz
measurement has exceeded the range. A higher
COM INPUT
range should be selected.
3) Under the manual range mode, when the scale
of the value to be measured is unknown beforehand,
select the highest range first and lower the
range gradually.
4.13 Measuring DC Voltage 4) “ ” means the maximum input voltage is 600V DC.
5) If the test result is more than 610V DC, symbol “O L”
WARNING will be displayed on LCD and the build-up buzzer
Beware of Electrocution. will sound.
Pay special attention to avoid electric shock
when measuring high voltage.
Do not input the voltage which more than
600V DC.

27 28
4.14 Measuring Frequency
4.14.1 By A range (from current clamp):
WARNING
9V
Beware of Electrocution.
Ensure that the test leads are disconnected
from the meter before making current clamp
measurements.
4.14.1.1 Set the rotary selector to the A range
(A~ or A ) position.
4.14.1.2 Press the trigger to open jaw. Fully enclose
only one conductor.
4.14.1.3 Press the “Hz/%” to switch to the frequency
measurement.
MIN 600A A
OFF 4.14.1.4 Take the reading on the LCD.
CAT III 600V

A Note:
V
1) Do not put more than one cable into the jaw during
test, otherwise incorrect test value might be obtained.
Ω 2) Frequency test range is 10Hz - 1kHz.‘00.0’ will be
SEL
displayed on LCD if the test frequency is lower than
OFF
10.0 Hz. It is possible to test the frequency which is
MIN B .L higher than 1 kHz but the tolerance of the test result
MAX RAN Hz/% HOLD
can not be ensure.
3) “ ” means the maximum input current is
INRUSH DIGITAL CLAMP 600A rms AC.
AUTO MANU MAX MIN ZERO

°C°F%
μmVA
nμmF

MkΩ
Hz

TRMS INRUSH

COM INPUT

29 30
4.14.2 By V range:
WARNING
Beware of Electrocution.
Pay special attention to avoid electric shock
when measuring high voltage.
Do not input the voltage which more than
600V rms AC.
4.14.2.1 Plug the black test lead into the COM jack
and the red test lead into the INPUT jack.
4.14.2.2 Set the rotary selector to the V range
position.
4.14.2.3 Press the "Hz/%" to switch to frequency
measurement.
OFF OFF
4.14.2.4 Connect test leads to the two ends of the
A A
source or load for measurement.
A A
4.14.2.5 Take the reading on the LCD.
V V
Note:
Ω Ω

SEL SEL
1) Frequency test range is 10Hz -10kHz. '00.0' will be
OFF OFF
displayed on LCD if the test frequency is lower than
MIN
MAX RAN Hz/% B.L
HOLD
MIN
MAX RAN Hz/% B.L
HOLD
10.0 Hz. It is possible to test the frequency which is
higher than 10kHz but the tolerance of the test result
INRUSH DIGITAL CLAMP INRUSH DIGITAL CLAMP
can not be ensure.
AUTO MANU MAX MIN ZERO AUTO MANU MAX MIN ZERO 2) “ ” means the maximum input voltage is
°C°F%
μmVA
nμmF
°C°F%
μmVA
nμmF
600V rms AC.
MkΩ MkΩ
Hz Hz

TRMS TRMS INRUSH


INRUSH

COM INPUT COM INPUT

600V 600V
CAT. III CAT. III
MAX 600V MAX 600V

31 32
4.15 Measuring Duty
4.15.1 By A range ( from current clamp):
WARNING
Beware of Electrocution.
Ensure that the test leads are disconnected
from the meter before making current clamp
measurements.
4.15.1.1 Set the rotary selector to the A range
(A or A ) position.
4.15.1.2 Press the trigger to open jaw. Fully enclose
only one conductor.
4.15.1.3 Press the "Hz/%" to switch to the DUTY
MIN 600A A
OFF measurement.
CAT III 600V
4.15.1.4 Take the reading on the LCD.
A

Note:
V
1) Do not put more than one cable into the jaw during
Ω test, otherwise incorrect test value might be obtained.
2) If the duty cycle is less than 10%, symbol 'UL' will be
SEL
OFF displayed on LCD; if the duty cycle is more than
MIN B .L
94.9%, symbol 'O L' will be displayed on LCD.
MAX RAN Hz/% HOLD 3) The input signal frequency range is 10 – 1kHz. It is
possible to test duty cycle of the higher than 1 kHz
frequency signal, but the tolerance of the test result
INRUSH DIGITAL CLAMP can not be ensure.
AUTO MANU MAX MIN ZERO

°C°F%
4) “ ” means the maximum input current is
μmVA
nμmF
600A rms AC.
MkΩ
Hz

TRMS INRUSH

COM INPUT

33 34
4.15.2 By V range:
WARNING
Beware of Electrocution.
Pay special attention to avoid electric shock
when measuring high voltage.
Do not input the voltage which more than
600V rms AC.
4.15.2.1 Plug the black test lead into the COM jack and
the red test lead into the INPUT jack.
4.15.2.2 Set the rotary selector to the V range position.
4.15.2.3 Press the "Hz/%" to switch to DUTY
measurement.
4.15.2.4 Connect test leads to the two end of the source
OFF OFF
or load for measurement.
A A
4.15.2.5 Take the reading on the LCD.
A A
Note:
V V
1) If the duty cycle is less than 10%, symbol 'UL' will be
Ω Ω
displayed on LCD; if the duty cycle is more than
SEL
OFF
SEL
OFF
94.9%, symbol 'O L' will be displayed on LCD.
MIN B.L MIN B.L 3) The input signal frequency range is 10 – 10 kHz. It is
RAN Hz/% HOLD RAN Hz/% HOLD
MAX MAX
possible to test duty cycle of the higher than 10 kHz
frequency signal, but the tolerance of the test result
INRUSH DIGITAL CLAMP INRUSH DIGITAL CLAMP
can not be ensure.
3) “ ” means the maximum input voltage is
AUTO MANU MAX MIN ZERO AUTO MANU MAX MIN ZERO

°C°F% °C°F%
μmVA μmVA
nμmF

MkΩ
Hz
nμmF

MkΩ
Hz
600V rms AC.
TRMS INRUSH TRMS INRUSH

COM INPUT COM INPUT

600V 600V
CAT. III CAT. III
MAX 600V MAX 600V

Correct Incorrect

35 36
4.16 Measuring Resistance
WARNING
Beware of Electrocution.
When measuring in-circuit resistance, make
sure that the power of the circuit under test
has been turned off and that all capacitors
have been fully discharged.
4.16.1 Plug the black test lead into the COM jack and
the red test lead into the INPUT jack.
4.16.2 Set the rotary selector to the Ω range
position to make the meter get into AC V range.
4.16.3 Auto range mode or manual range mode can be
MIN 600A
OFF selected by pressing the “RAN” button.
A
CAT III 600V 4.16.4 Connect the test leads to the ends of the resistor
A
or circuit for measurement.
4.16.5 Take the reading on the LCD.
V

Note:

1) At the manual range mode, when only 'O L' is shown
SEL
OFF on the LCD, it means the measurement has exceeded
the range. A higher range should be selected.
MIN B.L
MAX RAN Hz/% HOLD 2) When the input is open, 'O L' will appear on the LCD
to indicate that the range has been exceeded.
3) For measuring resistance above 1MΩ, it may take
INRUSH DIGITAL CLAMP a few seconds to get a steady reading. This is normal
AUTO MANU MAX MIN ZERO

°C°F%
for high resistance reading.
μmVA
nμmF

MkΩ
Hz

TRMS INRUSH

COM INPUT

37 38
4.17 Testing Diode
4.17.1 Plug the black test lead into the COM jack and
the red test lead into the INPUT jack.
4.17.2 Set the rotary selector to the Ω range
position.
4.17.3 Press the "S E L" button to switch to test.
4.17.4 Connect the red test lead to the anode and the
black test lead to the cathode of the diode for
testing.
4.17.5 Take the reading on the LCD.
Note:
1) The meter will show the approximate forward voltage
drop of the diode.
MAX600A OFF 2) When the test leads have been reversed or open,
CAT III 600V A
'O L' will appear on the LCD.
A

SEL
OFF

MIN B.L
MAX RAN Hz/% HOLD

INRUSH DIGITAL CLAMP


AUTO MANU MAX MIN ZERO

°C°F%
μmVA
nμmF

MkΩ
Hz

TRMS INRUSH

COM INPUT

39 40
4.18 Testing Continuity
WARNING
Beware of Electrocution.
Make sure that the power of the circuit has
been turned off and the capacitors have been
fully discharged before testing the
continuity of a circuit.
4.18.1 Plug the black test lead into the COM jack and
the red test lead into the INPUT jack.
4.18.2 Set the rotary selector to the Ω range
position.
4.18.3 Press the "S E L" button to switch to continuity
MAX600A OFF
test.
CAT III 600V A
4.18.4 Connect the test leads to the two ends of the
A circuit for measurement.
4.18.5 If the resistance of the circuit being tested is less
V
than 30 Ω , the built-in buzzer will sound.
4.18.6 Take the reading on the LCD.

SEL
Note:
OFF

If the test leads are open or the resistance of the circuit


MIN
MAX RAN Hz/%
B.L
HOLD
is over 660 Ω , “O L” will appear on the LCD.

INRUSH DIGITAL CLAMP

AUTO MANU MAX MIN ZERO

°C°F%
μmVA
nμmF

MkΩ
Hz

TRMS INRUSH

COM INPUT

41 42
4.19 Measuring Capacitance
WARNING
Beware of Electrocution.
To avoid electric shock, make sure that the
capacitors have been fully discharged
before measuring the capacitance of a
capacitor.
4.19.1 Plug the black test lead into the COM jack and
the red test lead into the INPUT jack.
4.19.2 Set the rotary selector to the range position.
4.19.3 After fully discharged the capacitor, connect the
test leads to the two ends of the capacitor for
MAX600A OFF measurement.
CAT III 600V A
4.19.4 Take the reading on the LCD.
A
Note:
V
It may take some time (about 10 seconds for the

66mF range) for steady readings when measuring
high capacity.
SEL
OFF

MIN B.L
MAX RAN Hz/% HOLD

INRUSH DIGITAL CLAMP


AUTO MANU MAX MIN ZERO

°C°F%
μmVA
nμmF

MkΩ
Hz

TRMS INRUSH

COM INPUT

43 44
5. Maintenance
5.1 Replacing The Batteries
WARNING
To avoid electric shock, make sure that the
test leads have been clearly move away from
the circuit under measurement before
opening the battery cover of the meter.

5.1.1 If the sign “ ” appears, it means that the


batteries should be replaced.
5.1.2 Loosen the fixing screw of the battery cover and
remove it.
MAX600A OFF 5.1.3 Replace the exhausted batteries with new ones.
CAT III 600V A
5.1.4 Put the battery cover back and fix it again to its
A origin form.
V
Note:
Do not reverse the poles of the batteries.

5.2 Replacing Test Leads
SEL
OFF

WARNING
B.L
MIN
MAX RAN Hz/% HOLD The replacement must be test leads in good
working condition with the same or
equivalent rating: 1000V 10A.
INRUSH DIGITAL CLAMP

AUTO MANU MAX MIN ZERO

°C°F%
A test lead must be replaced if the insulation layer has
μmVA
nμmF

MkΩ
been damaged, e.g. the wire inside is exposed.
Hz

TRMS INRUSH
6. Accessories
COM INPUT
1) Test Leads: Electric Ratings 1000V 10A 1 pair (set)
2) Operating Manual 1 copy
3) 1.5V AAA Battery 3 piece

45 46