M120TurboGen™
Retro-fit turbogenerator solution for
Mitsubishi S12 prime movers
• 6% Fuel Savings* • 120kW Power*

Standard Features Fuel savings (7500 hrs)


140000

• 50Hz (60 Hz Option) 120000


100000

380/410 VAC 3ph


Litres p.a.

• 80000
60000

• 2 x Turbogenerator 40000
20000
• 2 x Turbocharger 0
400 600 800 1000

2 x Power Electronics
kWm

cabinet
• CMM (condition
monitoring module) Options
• Alarm & Signal integration • Brackets and
• Full data access & logging connections
• CANbus • Modular system
• Cooling system • Remote access
• Lubrication system
• Cables
*Estimated subject to optimisation testing

The Bowman system facilitates full integration with engine electronics


for seamless and simultaneous startup and shutdown.

Turbogenerator Output Standard Features Power Electronics

Engine Output COP • 2 x Turbogenerator • Turbogenerator speed


kWm 981 • 2 x Turbocharger control (Patented)
Turbogenerator kWe (x2) 60 • 1 x CMM • 50 Hz / 60 Hz Option

DS 004 Issue 02
www.bowmanpower.com

M120TurboGen™
Retro-fit turbogenerator solution for Mitsubishi S12R-PTA-S prime movers

Turbochargers Power Electronics Kit Contents

• Turbochargers type - • Turbogenerator • 2 x TC81


optimised with speed control Turbocharger including
turbogenerators • 50 hz Grid Connected joints and fittings
• (60hz option) • 2 x G108-60-WTG
Turbogenerator Turbocharger • 3 phase Turbogenerator
• 400 VAC • 2 x Turbogenerator
• Up to 60kW (x2) support module
503 355
• Up to 100 amps • 2 x Power electronics
28 • Water cooled module
6
• Condition monitored
• 1 x Condition
494 333
monitoring module
Cooling System Electronics • 1 x Exhaust system
Turbogenerators connection kit
• 5m x Power Cable
• High speed
• 25m x Signal Cable
• Compact
455 • Arrangement drgs
1900
• Oil cooled
• Installation diagrams
• Speed control (Patented)
• Wiring diagrams
• Condition monitoring 400
• Set up instructions
560

400
480

Weights and Dimensions kg & mm Rating Definitions


Turbocharger Turbogenerator Power Cooling
Electronics System
• Maximum ambient
Length 286 528 400 400
55 deg C
Width 333 494 480 560 • Ingress protection
Height 355 503 1900 455 IP44 (PE IP20)
Weight kg 40kg 60kg 160kg 45kg
Quantity 2 2 2 2
Total kgs 80kg 120kg 320kg 90kg

Bowman Power Group Ltd Ocean Quay Belvidere Road Telephone. +44 (0)23 8023 6700
Southampton Hants UK SO14 5QY
www.bowmanpower.com