Professional Documents
Culture Documents
Water supply: water filter and transport in waterworks, boosting of main pipeline, boosting in high rise building.
Industrial boosting: process flow water system, cleaning system, high pressure washing system, fire fighting system.
Industrial liquid conveying: Cooling and air-conditioning system, boiler water supply and condensing system,
machine-associated purpose, acids and alkali.
Water treatment: ultrafiltration system, RO system, distillation system, separator, swimming pool.
Irrigation: Farmland irrigation, dripping irrigation.
Number of stages 10
OPERATION CONDITIONS
Thin,clean,non-flammable and non-explosive liquid containing no solid granules and fibers.
Liquid temperature:
Normal temperature type:-15 +70
Hot water type:+70 +120
Ambient temperature:up to+40
Altitude:up to 1000m
PUMP
CDL/CDLF pump are vertical non-self priming multistage centrifugal pump, which is driven by a standard electric
motor.The motor output shaft directly connects with the pump shaft through a coupling. The pressure resistant cylinder
and flow passage components are fixed between pump head and in-and outlet section with tie-bar bolts. The inlet and
outlet are located at the pump bottom at the same plane. This kind of pump can be equipped with an intelligent protector
to effectively prevent it from dry-running,out-of-phase and overload.
PUMP MOTOR
Totall-enclosed fan-cooled two-pole standard motor
Protection class:IP55
Insulation class:F
Standard voltage:60Hz:3 200-230/346V 3 200-200/346-400V 3 220-255/380-440V 3 220-277V/380-480V
2.8 CDL42/CDLF42
Stage 280
60Hz
-70
First number: stage 10 2.6 260
-70-2
100 Second number: 2.4 240
CDL8 CDL32
90 Number of small impeller. 2.2 220 -60
CDLF8 CDLF32 -60-2 Pump Q-H curve,the thickened line
80 2.0 200 present recommended performance
CDL42
70 1.8 180 region.
CDL2 CDL4 CDL16 CDLF42
60 1.6 160
CDLF2 CDLF4 CDLF16
50 1.4 140
1.2 120
40
1.0 100
30 0.8 80
0.6 60
20 0.4 40
3
0.8 1 2 3 4 5 6 7 8 9 10 20 30 40 50 70 90 Q[m /h] The power curve presents the 0.2 20
input power of each stage, which Eta curve means efficiency of the
0.0 0 3
0 5 10 15 20 25 30 35 40 45 50 55 60 65 Q [m /h] pump. For the pump equipped with
is divided into integrate impeller
Product range type(1/1) and the type with small 0 2 4 6 8 10 12 14 16 18 Q[l/S] small impeller, its efficiency will
impeller(2/3) be 2% lower than that shown by the
P2 P2
Eta[%]
Description CDL2 CDL4 CDL8 CDL16 CDL32 CDL42 [Hp] [kW] curve.
Eta
8 6.0 P21/1 80
6 4.5 P22/3 60
3
Rated flow m /h 2 4 8 16 32 42 4 3.0 40
2 1.5 20
0 0.0 0
Rated flow l/s 0 5 10 15 20 25 30 35 40 45 50 55 60 65 Q [m3/h]
0.56 1.1 2.2 4.4 8.9 11.7 Q-H H
[kPa] [ m ] NPSH[m]
QH3500pm1/1
Flow range m 3/h 1-4.5 2.5-9 7-14 10-26 20-48 30-65 400 40 QH3500pm2/3 16
300 30 12
200 20 8
NPSH
Flow range l/s 0.28-1.25 0.7-2.5 1.9-3.9 2.8-7.2 5.5-13.3 8.3-18 100 10 4
0 0 3
0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 Q [m /h]
Max.pressure bar 23.5 21 20 20 25 26 NPSH curve presents the average
value of all curves of this series.
Motor power kw 0.55-4 0.75-5.5 0.75-11 2.2-18.5 3-30 5.5-45 A safety margin of 0.5m shall be
taken into consideration when
Temperature range -15 +120 making selection.
The Q-H curve of eachstage, presenting integrate impeller type(1/1)and the
type equipped with small inpeller(2/3).
Max.efficiency % 46 59 64 66 76 78
Type
CDL
CDLF
CDL,CDLF42-10-1~42-20-2 4[bar]
CDL,CDLF42-20~42-40-2 10[bar]
CDL,CDLF42-40~42-70 15[bar]
P H CDL,CDLF2 Size(mm)
[Mpa] [m] Weight
Model
B1 B2 B1+B2 D1 D2 (kg)
CDL2/CDLF2
2.6 260
-180 6 0Hz Instrallation sketch CDLF2-20 233 210 443 148 117 20
2.4 240
CDLF2-30 261 245 506 170 142 20
2.2 220
-150
2.0 CDLF2-40 279 245 524 170 142 25
200
1.8 -130 CDLF2-50 297 245 542 170 142 25
180
1.6 160 CDLF2-60 315 245 560 170 142 25
-110
1.4 140
CDLF2-70 343 290 633 190 155 30
-90
1.2 120
CDLF2-90 379 290 669 190 155 35
1.0 100 -70
-60 CDLF2-110 415 290 705 190 155 35
0.8 80
-50
-40 CDLF2-130 461 315 776 197 165 40
0.6 60
-30
0.4 40 CDLF2-150 497 315 812 197 165 40
-20
0.2 20 CDLF2-180 551 335 886 230 185 45
0.0 0 3
0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 Q [m /h] Performance table
Motor(kw) Q
0 0.2 0.4 0.6 0.8 1.0 1.2 Q [l/s] Model (m3/h) 1 1.5 2 2.5 3 3.5 4 4..5
CDLF2-20 0.55 26 24 22 21 19 16 12 9
P2 P2 CDLF2-30 0.77 39 36 34 31 27 24 19 15
[Hp] [Kw] Eta [%]
CDLF2-40 1.1 52 48 45 42 36 32 26 20
0.25 CDLF2-50 1.1 65 61 57 52 46 41 33 25
0.30 Eta
0.20 40 CDLF2-60 1.1 78 74 69 63 56 49 40 30
0.20 0.15
0.10 P2 20 CDLF2-70 1.5 92 86 81 74 66 57 47 35
0.10 CDLF2-80 1.5 105 99 93 84 76 65 54 40
0.05
0.00 0.00 0 CDLF2-90 2.2 118 111 104 95 86 76 61 45
0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0
3
4.5 Q [m /h] H
CDLF2-100 2.2 131 124 116 106 96 84 68 50
(m)
Q-H H CDLF2-110 2.2 144 137 128 117 106 91 75 55
[kPa][m] NPSH [m]
CDLF2-120 3.0 158 150 140 128 116 100 82 60
QH 3500rpm
120 12 12 CDLF2-130 3.0 171 163 152 139 126 108 90 66
80 8 8 CDLF2-140 3.0 185 176 164 150 136 116 97 71
40 4 NPSH 4 CDLF2-150 3.0 198 188 176 161 146 125 104 77
0 0 0 CDLF2-160 4.0 211 202 188 172 156 133 111 82
3
0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 Q [m /h] CDLF2-170 4.0 225 215 190 183 166 142 118 88
CDLF2-180 4.0 238 228 212 195 175 151 126 94
1.4 140
-80 CDLF8-50 457 315 772 197 165 47
1.2 120
CDLF8-60 487 335 822 230 188 52
1.0 100 -60
-50 CDLF8-80 567 430 997 260 188 77
0.8 80
-40 CDLF8-100 627 430 1057 260 208 87
0.6 60
-30
0.4 40 -20 CDLF8-120 687 430 1117 260 208 90
0.2 20
CDLF8-140 835 490 1325 330 255 132
0.0 0
3
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Q[m /h] Performance table
0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 Q[I/S] Motor(kw) Q
Model (m3/h) 7 8 9 10 11 12 13 14
P2 P2 CDLF8-20 1.5 27 26 25 24 23 22 20 18
[Hp][kW] Eta[%] CDLF8-30 2.2 41 40 38 37 35 33 31 28
0.4 40 -20
CDLF16-90 830 550 1380 330 255 192
0.2 20
CDLF16-100 875 550 1425 330 255 192
0.0 0 3
0 2 4 6 8 10 12 14 16 18 20 22 24 26 Q [m /h] Performance table
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 Q[l/S] Q
Model Motor(kw) 10 12 14 16 18 20 22 24 26
(m3/h)
P2 P2 CDLF16-20 4.0 38 37.5 37 36 34 32 30 27 24
[Hp] [kW] Eta[%]
5 4 80 CDLF16-30 5.5 57 56 55 54 51 48 45 40 36
Eta
4 3 60
3 2 P2 40 CDLF16-40 7.5 76 75 73 72 68 64 60 54 49
2
1 1 20
0 0 0 CDLF16-50 11 96 94 92 90 85 80 75 68 62
3
0 2 4 6 8 10 12 14 16 18 20 22 24 26 Q [m /h] H
CDLF16-60 11 115 113 111 108 102 96 91 82 75
Q-H H (m)
[kPa] [ m ] NPSH[m]
CDLF16-70 15 135 132 129 126 119 113 106 96 88
20 8
150 QH 3500 rpm
15 6
100 10 4 CDLF16-80 15 155 152 148 144 137 130 122 111 101
50 5 NPSH 2
0 0 0 CDLF16-90 18.5 178 172 167 162 156 148 137 125 114
3
0 2 4 6 8 10 12 14 16 18 20 22 24 26 Q [m /h]
CDLF16-100 18.5 197 192 187 181 174 165 153 141 127
400 QH3500pm1/1 CDL42-50-2 30 169 164 159 156 152 143 133 122 110
40 16
300 30 QH3500pm2/3 12 CDL42-50 30 180 175 169 166 162 154 144 134 121
200 20 8 CDL42-60-2 37 205 200 193 189 184 174 163 149 134
100 NPSH 4
10
CDL42-60 37 215 210 203 199 195 185 174 161 147
0 0 0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 Q [m3/h] CDL42-70-2 45 245 239 231 226 221 209 195 180 162
CDL42-70 45 257 250 242 237 232 220 207 191 174