Professional Documents
Culture Documents
1
of
Revised by:
1
Project: Project desig
Checked by: LRFD
Lateral buckling (LRFD p.6-53) Plastic buckling moment (LRFD p.4-6) Local buckling flange web
(LRFD
Lp (ft) = 8 Mp (kips-ft) = 600 6.61029 47.7273
p.4-7)
Lr (ft) = 23.4518 Limiting buckling moment (LRFD p.4-6) p 10.8333 106.667
Mr (kips-ft) = 381.333 r 27.6524 161.667
Results: Max Deflection max (in) = 0.77568 at x (ft) = 18 due to live load
Load Combinations 1.4D 1.2D+1.6L 1.2D+1.0E+0.5L 1.2D+1.3W+0.5L
Moment Mu (kips-ft) = 209.676 503.713 280.968 280.968
at x (ft) = 18.000 18.000 18.000 18.000
Shear Vu (kips) = 24.112 56.668 31.918 31.918
at x (ft) = 0 0 0 0
Required Flexural Strength Mu (kips-ft) = 503.7 at x (ft) = 18
Required Shear Strength Vu (kips) = 56.67 at x (ft) = 0
Checkings:
Deflection (LRFD p.4-29) L / max = 556.9 > 240 YES
1
Revised by: Test1
of
Project: Test1
1
Checked by: Test2 LRFD
100
Moment (kips-ft)
600
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
x/L
80
60
40
Load case 1
Shear (kips)
20
Load case 2
0
Load case 3
-20 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
Load case 4
-40
-60
-80
x/L
Deflection Shape
0
0.1
0.2
0.3
Deflection (in)
0.4
0.5
0.6
0.7
0.8
0.9
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1