Professional Documents
Culture Documents
LED Operator
Installation Manual
Type JVOP-182
To properly use the product, read this manual thoroughly and retain
for easy reference, inspection, and maintenance. Ensure the end user
receives this manual.
安川インバータ オプション
LEDオペレータ
取扱説明書
形式 JVOP-182
製品を安全にお使い頂くために,この取扱説明書を必ずお読みください。
また,本書をお手元に保管していただくとともに,最終的に本製品をご使用になる
ユーザー様のお手元に確実に届けられるよう,お取り計らい願います。
YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual 3
1 Preface and Safety
4 YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual
1 Preface and Safety
◆ Applicable Documentation
The following manuals are available for the JVOP-182 LED Operator Option:
LED Operator
Yaskawa AC Drive Option LED Operator Installation Manual
J1000
The Technical Manual is packaged with the RS-232C Interface Option and
contains a basic overview of wiring, settings, functions, and fault diagnoses.
For the drive setup, refer to the drive Quick Start Guide or Technical Manual.
Yaskawa Drive
Refer to the manual of the drive this option is being used with.
STOP
The manual for the drive covers basic installation, wiring, operation procedures, functions,
troubleshooting, and maintenance information.
J1000 It also includes important information on parameter settings and how to tune the drive.
To obtain instruction manuals for Yaskawa products access these sites:
Europe: http://www.yaskawa.eu.com
1 周波数指令 : 6 モニタ :
2 正転逆転選択 : 7 ベリファイ :
3 出力周波数 : 8 セットアップ :
4 出力電流 : 9 パラメータ設定 :
5 出力電圧 :
WARNING
Japan: http://www.e-mechatronics.com
Risk of electric shock.
Read manual before installing.
Wait 1 minute for capacitor discharge after
disconnecting power supply.
To conform to requirements, make sure
危 険 けが、感電のおそれがあります。
据え付け、運転の前には必ず取扱説明書を読むこと。
通電中および電源遮断後1分以内はフロントカバーを
外さないこと。
400V級インバータの場合は、電源の中性点が接地
されていることを確認すること。( 対応)
YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual 5
1 Preface and Safety
◆ Terms
Note: Indicates a supplement or precaution that does not cause drive damage.
Indicates a drive feature or function that is only available in drive software
≥ 1010:
version 1010 or greater.
LED: Light emitting diode.
◆ Registered Trademarks
Company names and product names listed in this manual are the registered trademarks of
those companies.
DANGER
Indicates a hazardous situation, which, if not avoided, will result in death or serious
injury.
WARNING
Indicates a hazardous situation, which, if not avoided, could result in death or
serious injury.
CAUTION
Indicates a hazardous situation, which, if not avoided, could result in minor or
moderate injury.
6 YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual
1 Preface and Safety
NOTICE
Indicates an equipment damage message.
■ General Safety
General Precautions
• The diagrams in this section may include option units and drives without covers or safety shields to
illustrate details. Be sure to reinstall covers or shields before operating any devices. The option board
should be used according to the instructions described in this manual.
• Any illustrations, photographs, or examples used in this manual are provided as examples only and
may not apply to all products to which this manual is applicable.
• The products and specifications described in this manual or the content and presentation of the
manual may be changed without notice to improve the product and/or the manual.
• When ordering a new copy of the manual due to damage or loss, contact your Yaskawa
representative or the nearest Yaskawa sales office and provide the manual number shown on the
front cover.
DANGER
Heed the safety messages in this manual.
Failure to comply will result in death or serious injury.
The operating company is responsible for any injuries or equipment damage resulting
from failure to heed the warnings in this manual.
NOTICE
Do not expose the drive to halogen group disinfectants.
Failure to comply may cause damage to the electrical components in the option unit.
Do not pack the drive in wooden materials that have been fumigated or sterilized.
Do not sterilize the entire package after the product is packed.
YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual 7
2 Product Overview
2 Product Overview
◆ About This Product
The LED Operator Option provides an enhanced drive user interface that can operate the
Yaskawa drive at a short distance up to 3 meters. The LED Operator Option is an LED
display that simplifies the task of interfacing with the drive to perform these tasks:
• Read or modify drive parameters.
• Read and copy drive parameter settings to another Yaskawa drive.
• Operate the drive.
• Monitor drive operation status.
All keys except for the STOP key on the drives built-in LED operator will not function when
the LED Operator Option is connected to V1000 and J1000. <1>
<1> If desired, to also disable the STOP key on the drives built-in LED operator, set parameter o2-02 (STOP Key
Function Selection) to 0 (Disabled).
◆ Applicable Models
The LED Operator Option can be used with the drive models in Table 1.
Table 1 Applicable Drive Models
<1> See “PRG” on the drive nameplate for software version number.
8 YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual
3 Receiving
3 Receiving
Perform the following tasks after receiving the LED Operator Option:
• Inspect the LED Operator Option for damage.
If the LED Operator Option appears damaged upon receipt, contact the shipper
immediately.
• Verify receipt of the correct model by checking the model number printed on the Name
plate of the LED Operator Option.
• If you have received the wrong model or the LED Operator Option does not function
properly, contact your supplier.
MANUAL
Quantity: 1 1
YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual 9
3 Receiving
J1000
SI-232/J <3> 20
RS-232C Interface Option
Sold Separately;
EZZ020642A For use with holes 18
through the panel
Sold Separately;
EZZ020642B For use with panel 19
mounted threaded studs
◆ Tool Requirements
To install the LED operator on the door of the enclosure panel, the following tools are
required:
Table 4 Required Tools
10 YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual
4 LED Operator Option Components
B D
A S / N : J007XE273710001
E
YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual 11
4 LED Operator Option Components
◆ Keys
Refer to Figure 2 and Table 5 for details on key names and functions.
Figure 2
14 13 12
10
LO
ESC
1 RE 8
2 RESET ENTER 7
9
RUN STOP
3 4 5 6
Figure 2 Keys
Table 5 Key Names and Functions
12 YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual
4 LED Operator Option Components
Down Arrow Scrolls down to display the next item, selects parameter numbers
5
Key and increments setting values.
6 ST
TO
TOP
TO STOP Key Note: The STOP key can be enabled or disabled when operating
from the external terminal or network communications by setting
parameter o2-02.
ALM LED
11
Light
REV LED
12
Light
Refer to LED Screen Display on page 15
DRV LED
13
Light
FOUT LED
14
Light
<1> o2-01(LOCAL/REMOTE Key Function Selection) is not compatible with J1000. LO/RE Selection Key is always
effective.
YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual 13
4 LED Operator Option Components
Flashing
LED Illuminated Flashing <1> Quickly <1> Off
1s
ON ON
Flashing
ON ON ON ON
Flashing
quickly
Figure 3 RUN LED Status
14 YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual
4 LED Operator Option Components
Figure 4
Flashing
Figure 4 RUN LED and Drive Operation
YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual 15
5 Installation Procedure
5 Installation Procedure
◆ Section Safety
NOTICE
Damage to Equipment
Use only Yaskawa connection cables or recommended cables.
Failure to comply may cause the drive or LED Operator Option to function incorrectly.
Properly connect the connectors.
Failure to comply may prevent proper operation and possibly damage equipment.
Do not exceed communication cable bend radius specifications.
Failure to comply may result in broken wires or loose connections.
16 YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual
5 Installation Procedure
S / N : J007XE273710001
90 (3.54)
78 (3.07)
15 (0.59)
<1>
7.9 44 (1.73)
60 (2.36)
(0.31)
minimum
50 (1.97) Unit: mm (in)
<1> Use only Yaskawa cables or cables recommended by Yaskawa. Refer to Item Names and Part Numbers (Sold
Separately) on page 10
Figure 5 Dimensions
YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual 17
5 Installation Procedure
NOTICE: Prevent foreign matter such as metal shavings or wire clippings from falling into the drive during
installation and project construction. Failure to comply could result in damage to the drive. Place a
temporary cover over the top of the drive during installation. Remove the temporary cover before startup, as
the cover will reduce ventilation and cause the drive to overheat.
■ External/Face-mount Installation
1. Cut an opening in the enclosure panel for the LED Operator Option according to
Figure 6.
2. Position the LED Operator Option so the LED display faces outwards, and mount
Figure 6
it to the enclosure panel as shown in Figure 6.
Enclosure panel
Unit: mm (in)
Figure 6 External/Face-mount Installation
Figure 7
22 (0.87)
78 (3.07)
(1.02)
26
(0.87)
22
2 (0.08)
14 22(0.87)
(0.55) Unit : mm (in)
Figure 7 Panel Cut-out Dimensions (External/Face-mount Installation)
18 YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual
5 Installation Procedure
■ Internal/Flush-mount Installation
The internal flush-mount installation method requires an installation support that is
purchased separately. Refer to Item Names and Part Numbers (Sold Separately) on
page 10 for information regarding the installation support and mounting hardware. Figure 8
illustrates how to attach the Installation Support A.
1. Cut an opening in the enclosure panel for the LED Operator Option according to
Figure 9.
2. Mount the LED Operator Option to the installation support (sold separately).
Figure 8
3. Mount the installation support and LED Operator Option to the enclosure panel.
Enclosure panel
LED Operator
M4 × 10 (0.39)
Phillips truss head screw × 4 Installation Support A
(for panel widths between
1 (0.04) and 1.6 (0.06)) M3 × 6 (0.24)
Phillips recessed
pan head machine screw × 2
Unit: mm (in)
45 (1.77)
59 +0.5
0 ( 2.32 0 )
+0.02
Unit : mm (in)
YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual 19
5 Installation Procedure
Drive
LED Operator Option (JVOP-182)
LED
Operator Comm Port
STOP S / N : J007XE273710001
危 険 けが、感電のおそれがあります。
据え付け、運転の前には必ず取扱説明書を読むこと。
通電中および電源遮断後5分以内はフロントカバーを
外さないこと。
400V級インバータの場合は、電源の中性点が接地
されていることを確認すること。( 対応)
Communication Cable Connector
20 YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual
5 Installation Procedure
Note: The STOP key on the drives built-in LED operator is the only functional key on the built-in LED
operator when the LED Operator Option is connected to the drive and parameter b1-02 is set to 0
(LED Operator Option). To disable the STOP key, set parameter o2-02 (STOP key Function
Selection) to 0 (Disable).
Figure 11
LED
Operator STOP
S / N : J007XE273710001
J1000
RS-232C Comm Port
Interface
Option
1 周波数指令 : 6 モニタ :
2 正転逆転選択 : 7 ベリファイ :
3 出力周波数 : 8 セットアップ :
4 出力電流 : 9 パラメータ設定 :
5 出力電圧 :
危 険 けが、感電のおそれがあります。
据え付け、運転の前には必ず取扱説明書を読むこと。
通電中および電源遮断後 1分以内はフロントカバーを
外さないこと。
YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual 21
6 Basic Operation
6 Basic Operation
◆ Basic Operation for LED Operator
The LED Operator Option operates in the same way as the LED Operator built in the drive.
Refer to the J1000 Manuals for LED Operator Option main structure and basic Operation.
22 YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual
6 Basic Operation
Step Display/Result
1. Turn on the power to the drive. The initial display appears. REV DRV
DRV FOUT
Press .
7. Press repeatedly until the display returns to the initial REV DRV
DRV FOUT
display.
YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual 23
7 Related Parameters
7 Related Parameters
Parameters related to the use of the LED Operator Option are listed below. Set these
parameters as needed for the application.
The symbol “{” in the J1000 column indicates this parameter No. applies to the J1000
drive. The symbol “{” in the A1000, V1000 column indicates this parameter No. applies to
A1000 and V1000 drives.
Table 8 Related Parameters
Drive
No. Name A1000x Description Default
J1000
V1000
Selects the source of the frequency reference.
0: Operator -Digital preset speed d1-01 to d1-17
Frequency
1: Terminals - Analog input terminal A1 or A2
b1-01 Reference { { 2: MEMOBUS/Modbus serial communications
1
Selection 1
3: Option PCB
4: Pulse Input (Terminal RP) <1>
Selects the run command input source.
0: Operator -RUN and STOP keys on the LED
Run Command Operator Option
b1-02
Selection 1 { { 1: Digital input terminals S1 to S7
1
2: MEMOBUS/Modbus serial communications
3: Option PCB <1>
Selects the frequency reference input source.
0: Operator - Digital preset speed d1-01 to d1-17
Frequency 1: Terminals - Analog input terminal A1 or A2
b1-15
Reference 2
× { 2: MEMOBUS/Modbus serial communications
0
3: Option PCB
4: Pulse Input (Terminal RP)
Selects the Run command input source.
0: Operator - RUN and STOP keys on the LED
Run Command Operator Option
b1-16
Source 2
× { 1: Digital input terminals S1 to S7
0
2: MEMOBUS/Modbus serial communications
3: Option PCB
LOCAL/ Enables/Disables the LED Operator Option LOCAL/
REMOTE Key REMOTE key.
o2-01
Function
× { 0: Disabled
1
Selection 1: Enabled
Enables/Disables the operator panel STOP key when
STOP Key the drive is operated form external sources (not
o2-02 Function { { operator). 1
Selection 0: Disabled
1: Enabled
24 YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual
7 Related Parameters
Drive
No. Name A1000x Description Default
J1000
V1000
Selects if the ENTER key press is required when
inputting the frequency reference by the operator
Frequency
keypad.
Reference
o2-05
Setting Method { { 0: Data/Enter key must be pressed to enter a 0
frequency reference.
Selection
1: Data/Enter key is not required. The frequency
reference is adjusted by the up and down arrow keys.
Operation Sets drive action when the LED Operator Option is
Selection removed in LOCAL mode or with b1-02 = 0.
o2-06 when LED { { 0: The drive will continue operation. 0
Operator Option 1: The drive will trigger a fault (oPr) and the motor
is Disconnected will coast to stop.
This parameter controls the copying of parameters to
and from the LED Operator Option.
0: COPY SELECT (no function)
1: All parameters are copied from the drive to the
LED Operator Option.
2: All parameters are copied from the LED Operator
Copy Function
o3-01
Selection { { Option to the drive. 0
3: Parameter settings in the drive are compared to
those in the LED Operator Option.
Note: When using the copy function, the drive model
number (o2-04), software number (U1-14), and
control method (A1-02) must match or an error will
occur.
Enables or disables reading of drive parameter
settings.
o3-02 Copy Allowable { { 0: Disabled - Read not allowed
0
1: Enabled - Read allowed
<1> b1-01 = 4 and b1-02 = 3 are not compatible with the J1000 drive.
YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual 25
8 LED Operator Option Fault Diagnostics
26 YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual
8 LED Operator Option Fault Diagnostics
YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual 27
9 Specifications
9 Specifications
Table 10 LED Operator Option Specifications
Model JVOP-182
Connector RJ-45
Power Supply Powered from the drive (DC +5 V ±5%)
Operating
-10 to +50 °C
Temperature
Humidity up to 95% RH (no condensation)
-20 to +60 °C
Storage Temperature
(allowed for short-term transport of the product)
Area of Use Indoor (free of corrosive gas, airborne particles, etc.)
Altitude Up to 1000 m
10 to 20 Hz : 9.8 m/s2
Shock
20 to 55 Hz : 5.9 m/s2
Read Function
Estimated 100,000 times
Limitation
28 YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual
10 Revision History
10 Revision History
The revision dates and numbers of the revised manuals are given on the bottom of the back
cover.
YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual 29
YASKAWA AC Drive Option
LED Operator
Installation Manual
YASKAWA
In the event that the end user of this product is to be the military and said product is to be employed in any weapons systems or the manufacture
thereof, the export will fall under the relevant regulations as stipulated in the Foreign Exchange and Foreign Trade Regulations. Therefore, be sure
to follow all procedures and submit all relevant documentation according to any and all rules, regulations and laws that may apply.
Specifications are subject to change without notice for ongoing product modifications and improvements.
© 2008 YASKAWA ELECTRIC CORPORATION. All rights reserved.