YASKAWA AC Drive Option

LED Operator
Installation Manual
Type JVOP-182
To properly use the product, read this manual thoroughly and retain
for easy reference, inspection, and maintenance. Ensure the end user
receives this manual.

安川インバータ オプション

LEDオペレータ
取扱説明書
形式 JVOP-182

製品を安全にお使い頂くために,この取扱説明書を必ずお読みください。
また,本書をお手元に保管していただくとともに,最終的に本製品をご使用になる
ユーザー様のお手元に確実に届けられるよう,お取り計らい願います。

MANUAL NO. TOBP C730600 35B


Table of Contents

1 PREFACE AND SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4


2 PRODUCT OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
3 RECEIVING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
4 LED OPERATOR OPTION COMPONENTS . . . . . . . . . . . . . 11
5 INSTALLATION PROCEDURE . . . . . . . . . . . . . . . . . . . . . . . 16
6 BASIC OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
7 RELATED PARAMETERS . . . . . . . . . . . . . . . . . . . . . . . . . . 24
8 LED OPERATOR OPTION FAULT DIAGNOSTICS . . . . . . . 26
9 SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
10 REVISION HISTORY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

Copyright © 2008 YASKAWA ELECTRIC CORPORATION


All rights reserved. No part of this publication may be reproduced, stored in a
retrieval system, or transmitted, in any form or by any means, mechanical,
electronic, photocopying, recording, or otherwise, without the prior written
permission of Yaskawa. No patent liability is assumed with respect to the use of the
information contained herein. Moreover, because Yaskawa is constantly striving to
improve its high-quality products, the information contained in this manual is
subject to change without notice. Every precaution has been taken in the
preparation of this manual. Yaskawa assumes no responsibility for errors or
omissions. Neither is any liability assumed for damages resulting from the use of
the information contained in this publication.

YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual 3
1 Preface and Safety

1 Preface and Safety


Yaskawa manufactures products used as components in a wide variety of industrial systems
and equipment. The selection and application of Yaskawa products remain the responsibility
of the equipment manufacturer or end user. Yaskawa accepts no responsibility for the way its
products are incorporated into the final system design. Under no circumstances should any
Yaskawa product be incorporated into any product or design as the exclusive or sole safety
control. Without exception, all controls should be designed to detect faults dynamically and
fail safely under all circumstances. All systems or equipment designed to incorporate a
product manufactured by Yaskawa must be supplied to the end user with appropriate
warnings and instructions as to the safe use and operation of that part. Any warnings
provided by Yaskawa must be promptly provided to the end user. Yaskawa offers an express
warranty only as to the quality of its products in conforming to standards and specifications
published in the Yaskawa manual. NO OTHER WARRANTY, EXPRESSED OR IMPLIED,
IS OFFERED. Yaskawa assumes no liability for any personal injury, property damage,
losses, or claims arising from misapplication of its products.

4 YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual
1 Preface and Safety

◆ Applicable Documentation
The following manuals are available for the JVOP-182 LED Operator Option:

LED Operator
Yaskawa AC Drive Option LED Operator Installation Manual

Read this manual first.


The installation manual is packaged with the LED Operator Option and
contains a basic overview of wiring, settings, functions, and fault
diagnoses.

RS-232C Interface Option


Yaskawa AC Drive -RS-232C Interface Option Technical Manual

J1000
The Technical Manual is packaged with the RS-232C Interface Option and
contains a basic overview of wiring, settings, functions, and fault diagnoses.

For the drive setup, refer to the drive Quick Start Guide or Technical Manual.

Yaskawa Drive

Refer to the manual of the drive this option is being used with.
STOP
The manual for the drive covers basic installation, wiring, operation procedures, functions,
troubleshooting, and maintenance information.
J1000 It also includes important information on parameter settings and how to tune the drive.
To obtain instruction manuals for Yaskawa products access these sites:
Europe: http://www.yaskawa.eu.com
1 周波数指令 : 6 モニタ :
2 正転逆転選択 : 7 ベリファイ :
3 出力周波数 : 8 セットアップ :
4 出力電流 : 9 パラメータ設定 :
5 出力電圧 :

WARNING
Japan: http://www.e-mechatronics.com
Risk of electric shock.
Read manual before installing.
Wait 1 minute for capacitor discharge after
disconnecting power supply.
To conform to requirements, make sure

Other areas: contact a Yaskawa representative.


to ground the supply neutral for 400V class.

危 険 けが、感電のおそれがあります。
据え付け、運転の前には必ず取扱説明書を読むこと。
通電中および電源遮断後1分以内はフロントカバーを
外さないこと。
400V級インバータの場合は、電源の中性点が接地
されていることを確認すること。(  対応)

YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual 5
1 Preface and Safety

◆ Terms

Note: Indicates a supplement or precaution that does not cause drive damage.
Indicates a drive feature or function that is only available in drive software
≥ 1010:
version 1010 or greater.
LED: Light emitting diode.

◆ Registered Trademarks
Company names and product names listed in this manual are the registered trademarks of
those companies.

◆ Supplemental Safety Information


Read and understand this manual before installing, operating or servicing this option unit.
The option unit must be installed according to this manual and local codes.
The following conventions are used to indicate safety messages in this manual. Failure to
heed these messages could result in serious or possibly even fatal injury or damage to the
products or to related equipment and systems.

DANGER
Indicates a hazardous situation, which, if not avoided, will result in death or serious
injury.

WARNING
Indicates a hazardous situation, which, if not avoided, could result in death or
serious injury.

CAUTION
Indicates a hazardous situation, which, if not avoided, could result in minor or
moderate injury.

6 YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual
1 Preface and Safety

NOTICE
Indicates an equipment damage message.

■ General Safety

General Precautions
• The diagrams in this section may include option units and drives without covers or safety shields to
illustrate details. Be sure to reinstall covers or shields before operating any devices. The option board
should be used according to the instructions described in this manual.
• Any illustrations, photographs, or examples used in this manual are provided as examples only and
may not apply to all products to which this manual is applicable.
• The products and specifications described in this manual or the content and presentation of the
manual may be changed without notice to improve the product and/or the manual.
• When ordering a new copy of the manual due to damage or loss, contact your Yaskawa
representative or the nearest Yaskawa sales office and provide the manual number shown on the
front cover.

DANGER
Heed the safety messages in this manual.
Failure to comply will result in death or serious injury.
The operating company is responsible for any injuries or equipment damage resulting
from failure to heed the warnings in this manual.

NOTICE
Do not expose the drive to halogen group disinfectants.
Failure to comply may cause damage to the electrical components in the option unit.
Do not pack the drive in wooden materials that have been fumigated or sterilized.
Do not sterilize the entire package after the product is packed.

YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual 7
2 Product Overview

2 Product Overview
◆ About This Product
The LED Operator Option provides an enhanced drive user interface that can operate the
Yaskawa drive at a short distance up to 3 meters. The LED Operator Option is an LED
display that simplifies the task of interfacing with the drive to perform these tasks:
• Read or modify drive parameters.
• Read and copy drive parameter settings to another Yaskawa drive.
• Operate the drive.
• Monitor drive operation status.
All keys except for the STOP key on the drives built-in LED operator will not function when
the LED Operator Option is connected to V1000 and J1000. <1>
<1> If desired, to also disable the STOP key on the drives built-in LED operator, set parameter o2-02 (STOP Key
Function Selection) to 0 (Disabled).

◆ Applicable Models
The LED Operator Option can be used with the drive models in Table 1.
Table 1 Applicable Drive Models

Drive Drive Software Version <1>


A1000 ≥ 1010
J1000 ≥ 1010
V1000 ≥ 1016

<1> See “PRG” on the drive nameplate for software version number.

8 YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual
3 Receiving

3 Receiving
Perform the following tasks after receiving the LED Operator Option:
• Inspect the LED Operator Option for damage.
If the LED Operator Option appears damaged upon receipt, contact the shipper
immediately.
• Verify receipt of the correct model by checking the model number printed on the Name
plate of the LED Operator Option.
• If you have received the wrong model or the LED Operator Option does not function
properly, contact your supplier.

◆ Contents and Packaging


Table 2 Contents of Package

Description: LED Operator Option Installation Manual

MANUAL

Quantity: 1 1

■ Additional Part Required (Sold Separately)


Proper installation of the LED Operator Option requires a communication cable. A
communication cable is not provided. A connection cable can be purchased from Yaskawa
or recommended LAN cables may be used. Refer to Table 3 for more information regarding
the cable required for your application.
Depending on the LED Operator Option installation method, an installation support listed in
Table 3 may also be required. Refer to Installing the LED Operator Option on page 17 for
more information regarding installation methods.
To order a cable or an installation support, contact Yaskawa directly or your nearest Yaskawa
distributor.

YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual 9
3 Receiving

Table 3 Item Names and Part Numbers (Sold Separately)

Item Yaskawa Part Number Notes Page

J1000
SI-232/J <3> 20
RS-232C Interface Option

WV001 <2> Sold Separately 20


Communication Cable (1 m)

WV003 <2> Sold Separately 20


Communication Cable (3 m)

Sold Separately;
EZZ020642A For use with holes 18
through the panel

Installation Support Set A

Sold Separately;
EZZ020642B For use with panel 19
mounted threaded studs

Installation Support Set B <1>


<1> If weld studs are on the back of the panel, use the Installation Support Set B.
<2> Alternate cables (customer supplied), RJ45 8 pin Straight Connector UTP Cat 5e cable.
<3> To connect the LED operator to J1000, install the RS-232C Interface Option to the drive.

◆ Tool Requirements
To install the LED operator on the door of the enclosure panel, the following tools are
required:
Table 4 Required Tools

Installation Location Installation Support Required Tools


External/Face Mount – Phillips screwdriver, M3
Installation Set A Phillips screwdriver, M3, M4
Internal/Flush Mount Phillips screwdriver, M3
Installation Set B
Box end or adjustable wrench, M4

10 YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual
4 LED Operator Option Components

4 LED Operator Option Components


◆ LED Operator Option
Figure 1

B D

A S / N : J007XE273710001
E

A – Data Display Area D – Installation Mounting Holes


B – LED Indicators E – Nameplate
C – Keys F – Communication Cable Connector

Figure 1 LED Operator Option Components

YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual 11
4 LED Operator Option Components

◆ Keys
Refer to Figure 2 and Table 5 for details on key names and functions.
Figure 2

14 13 12

DIGITAL OPERATOR JVOP-182 ALM 11


REV DRV FOUT

10
LO
ESC
1 RE 8

2 RESET ENTER 7
9
RUN STOP

3 4 5 6
Figure 2 Keys
Table 5 Key Names and Functions

No. Key Name Function


• Returns to the previous display.
• Moves the cursor one space to the left.
1 ESC Key
• Pressing and holding this button will return to the Frequency
Reference display.

• Moves the cursor to the right.


2 RESET Key
• Resets the drive to clear a fault situation.

3 RUN RUN Key Starts the drive and motor.

Up Arrow Scrolls up to display the next item, selects parameter numbers


4
Key and increments setting values.

12 YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual
4 LED Operator Option Components

No. Key Name Function

Down Arrow Scrolls down to display the next item, selects parameter numbers
5
Key and increments setting values.

Stops drive operation.

6 ST
TO
TOP
TO STOP Key Note: The STOP key can be enabled or disabled when operating
from the external terminal or network communications by setting
parameter o2-02.

• Enters parameter values and settings.


7 ENTER Key
• Selects a menu item to move between displays.

Switches the drive between operator (LOCAL) control and


control circuit terminals (REMOTE).
LO/RE
8 Selection Note: The LOCAL/REMOTE key is only effective at a stop in
Key drive mode. As a safety precaution, it is possible to disable the
LO/RE Selection Key by setting parameter o2-01 (LOCAL/
REMOTE Key Function Selection) to “0” (disabled). <1>

Illuminated while the drive is operating the motor.


9 RUN Light Refer to LED Operator LED Status Indicators on page 14 for
detail.

LO Illuminated while the drive is under LED Operator control when


10 LO/RE Light
RE (LOCAL) is selected to run the drive.

ALM LED
11
Light
REV LED
12
Light
Refer to LED Screen Display on page 15
DRV LED
13
Light
FOUT LED
14
Light
<1> o2-01(LOCAL/REMOTE Key Function Selection) is not compatible with J1000. LO/RE Selection Key is always
effective.

YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual 13
4 LED Operator Option Components

◆ LED Operator LED Status Indicators


Table 6 LED Status and Meaning

Flashing
LED Illuminated Flashing <1> Quickly <1> Off

LO/RE Run command is


When the run
LED selected from a
command is selected
– – device other than the
LO from the LED
LED operator
RE operator (LOCAL).
(REMOTE).
• During
• During
deceleration to
RUN LED deceleration at a
stop.
fast-stop.
During run. • When a run During stop.
RUN • During stop by
command is input
External Fault
and the frequency
digital input.
reference is 0 Hz.
<1> For the difference between “Flashing” and “Flashing Quickly” of the RUN LED, refer to Figure 3, RUN LED
Status.
Figure 3

1s

ON ON
Flashing

ON ON ON ON
Flashing
quickly
Figure 3 RUN LED Status

14 YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual
4 LED Operator Option Components

Figure 4

Drive output frequency


During stop RUN STOP RUN STOP
RUN
/ STOP
6 Hz
0 Hz
Frequency setting
RUN LED OFF ON OFF OFF

Flashing
Figure 4 RUN LED and Drive Operation

◆ LED Screen Display

Display Lit Flashing Off


When the drive detects an alarm • When an alarm occurs
Normal state (no fault or alarm)
or error • OPE detected

Motor is rotating in reverse – Motor is rotating forward

Drive Mode – Programming Mode

Displays output frequency (Hz) – –

DIGITAL OPERATOR JVOP-182 ALM DIGITAL OPERATOR JVOP-182


ALM
ALM DIGITAL OPERATOR JVOP-182 ALM

As illustrated REV DRV


DRV FOUT REV DRV FOUT REV DRV
DRV FOUT
in this manual

YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual 15
5 Installation Procedure

5 Installation Procedure
◆ Section Safety

NOTICE
Damage to Equipment
Use only Yaskawa connection cables or recommended cables.
Failure to comply may cause the drive or LED Operator Option to function incorrectly.
Properly connect the connectors.
Failure to comply may prevent proper operation and possibly damage equipment.
Do not exceed communication cable bend radius specifications.
Failure to comply may result in broken wires or loose connections.

16 YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual
5 Installation Procedure

◆ LED Operator Option Dimensions


Figure 5

12.2 1.6 (0.06) Installation holes (2-M3 screws, depth 5 (0.2))


(0.48)

S / N : J007XE273710001
90 (3.54)

78 (3.07)
15 (0.59)
<1>

7.9 44 (1.73)
60 (2.36)
(0.31)
minimum
50 (1.97) Unit: mm (in)

<1> Use only Yaskawa cables or cables recommended by Yaskawa. Refer to Item Names and Part Numbers (Sold
Separately) on page 10

Figure 5 Dimensions

◆ Installing the LED Operator Option


There are two different installation methods for the LED Operator Option depending on the
application.
1. External/Face-mount: Mounted outside a panel.
2. Internal/Flush-mount: Mounted inside a panel.
Table 7 LED Operator Option Installation Methods

Installation Method Description Notes


Simplified installation with the LED Operator is
External/Face-mount mounted on the outside of the panel with two –
screws.

YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual 17
5 Installation Procedure

Installation Method Description Notes


Requires purchase of
Encloses the LED Operator Option in the panel. separate items. Refer to
Internal/Flush-mount The LED Operator is flush with the outside of the Item Names and Part
panel. Numbers (Sold
Separately) on page 10

NOTICE: Prevent foreign matter such as metal shavings or wire clippings from falling into the drive during
installation and project construction. Failure to comply could result in damage to the drive. Place a
temporary cover over the top of the drive during installation. Remove the temporary cover before startup, as
the cover will reduce ventilation and cause the drive to overheat.

■ External/Face-mount Installation
1. Cut an opening in the enclosure panel for the LED Operator Option according to
Figure 6.
2. Position the LED Operator Option so the LED display faces outwards, and mount
Figure 6
it to the enclosure panel as shown in Figure 6.

LED Operator Option M3 × 6 (0.24)


Phillips recessed
pan head machine screw × 2

Enclosure panel

Unit: mm (in)
Figure 6 External/Face-mount Installation
Figure 7

22 (0.87)
78 (3.07)

(1.02)
26
(0.87)
22
2 (0.08)

14 22(0.87)
(0.55) Unit : mm (in)
Figure 7 Panel Cut-out Dimensions (External/Face-mount Installation)

18 YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual
5 Installation Procedure

■ Internal/Flush-mount Installation
The internal flush-mount installation method requires an installation support that is
purchased separately. Refer to Item Names and Part Numbers (Sold Separately) on
page 10 for information regarding the installation support and mounting hardware. Figure 8
illustrates how to attach the Installation Support A.
1. Cut an opening in the enclosure panel for the LED Operator Option according to
Figure 9.
2. Mount the LED Operator Option to the installation support (sold separately).
Figure 8
3. Mount the installation support and LED Operator Option to the enclosure panel.
Enclosure panel
LED Operator
M4 × 10 (0.39)
Phillips truss head screw × 4 Installation Support A
(for panel widths between
1 (0.04) and 1.6 (0.06)) M3 × 6 (0.24)
Phillips recessed
pan head machine screw × 2

Unit: mm (in)

Figure 8 Internal/Flush Mount Installation


Note: For environments with a significant amount of dust or other airborne debris, use a gasket
between the enclosure panel and the LED Operator Option.
Figure 9
+0.02
)
120 (4.72)
0 ( 35 0
89 +0.5

45 (1.77)

59 +0.5
0 ( 2.32 0 )
+0.02
Unit : mm (in)

Figure 9 Panel Cut-out Dimensions (Internal/Flush-mount Installation)

YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual 19
5 Installation Procedure

◆ Connecting the LED Operator Option to the Drive


This section contains instructions for connecting the LED operator to V1000 and J1000. For
instructions on connecting the LED operator to the other drives, see the Technical Manual of
the drive connected to the LED operator.
■ Connecting the LED Operator Option to V1000
Plug the communication cable into the communication cable connector of the LED Operator
Option and the drive communications port as shown in Figure 11. Ensure both cable ends
are firmly connected. Refer to Item Names and Part Numbers (Sold Separately) on
page 10 for information regarding recommended cables.
Note: Use only Yaskawa recommended cables. Using a cable not specified may cause the LED
Operator or drive to malfunction.
Note: The STOP key on the drives built-in LED operator is the only functional key on the built-in LED
operator when the LED Operator Option is connected to the drive and parameter b1-02 is set to 0
(LED Operator Option). To disable the STOP key, set parameter o2-02 (STOP key Function
Selection) to 0 (Disable).
Figure 10

Drive
LED Operator Option (JVOP-182)

LED
Operator Comm Port
STOP S / N : J007XE273710001

V1000 周波数指令 : (Hz)


正転逆転選択 :
出力周波数 : (Hz)
出力電流 : (A)
出力電圧 : (V)
モニタ :
ベリファイ :
セットアップ :
パラメータ設定 :
オートチューニング :

WARNING Risk of electric shock.


Read manual before installing.
Wait 5 minutes for capacitor discharge after
disconnecting power supply.
To conform to requirements, make sure
to ground the supply neutral for 400V class.

危 険 けが、感電のおそれがあります。
据え付け、運転の前には必ず取扱説明書を読むこと。
通電中および電源遮断後5分以内はフロントカバーを
外さないこと。
400V級インバータの場合は、電源の中性点が接地
されていることを確認すること。(  対応)
Communication Cable Connector

Figure 10 Communication Cable Connection

20 YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual
5 Installation Procedure

■ Connecting the LED Operator to J1000


Note: Attach the RS-232C Interface Option (SI-232/J) to the drive before connecting the LED
Operator Option to the drive.
Plug the communication cable into the communication cable connector of the LED Operator
Option and the communications port of the RS-232C Interface Option (SI-232/J) as shown
in Figure 11. Ensure both cable ends are firmly connected. Refer to Item Names and Part
Numbers (Sold Separately) on page 10 for information regarding recommended cables.
NOTICE: Use only Yaskawa recommended cables. Using a cable not specified may cause the LED
Operator or drive to malfunction.

Note: The STOP key on the drives built-in LED operator is the only functional key on the built-in LED
operator when the LED Operator Option is connected to the drive and parameter b1-02 is set to 0
(LED Operator Option). To disable the STOP key, set parameter o2-02 (STOP key Function
Selection) to 0 (Disable).
Figure 11

Drive LED Operator Option (JVOP-182)

LED
Operator STOP

S / N : J007XE273710001

J1000
RS-232C Comm Port
Interface
Option
1 周波数指令 : 6 モニタ :
2 正転逆転選択 : 7 ベリファイ :
3 出力周波数 : 8 セットアップ :
4 出力電流 : 9 パラメータ設定 :
5 出力電圧 :

WARNING Risk of electric shock.


Read manual before installing.
Wait 1 minute for capacitor discharge after
disconnecting power supply.
To conform to requirements, make sure
to ground the supply neutral for 400V class.

危 険 けが、感電のおそれがあります。
据え付け、運転の前には必ず取扱説明書を読むこと。
通電中および電源遮断後 1分以内はフロントカバーを
外さないこと。

Communication Cable Connector


400V級インバータの場合は、電源の中性点が接地
されていることを確認すること。(  対応)

Figure 11 Communication Cable Connection

YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual 21
6 Basic Operation

6 Basic Operation
◆ Basic Operation for LED Operator
The LED Operator Option operates in the same way as the LED Operator built in the drive.
Refer to the J1000 Manuals for LED Operator Option main structure and basic Operation.

◆ Functions characteristic of the LED Operator Option


■ Read/Copy Function Procedure
Read
Reads and saves parameter settings from the drive to the LED Operator Option.
The LED Operator Option can perform the Read function an estimated 100,000 times.
Copy
Copies the parameter settings from the LED Operator Option to another Yaskawa drive.
Verify
Verifies parameter settings in the drive match parameter settings saved to the LED Operator
Option.

22 YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual
6 Basic Operation

The following procedure is used to read parameters from the drive.


Note: Set parameter o3-02 (Read Allowable) to "1" (Enable) to read the parameter settings from the
drive. Set parameter o3-02 to "0" (disable) to protect the parameter settings in the LED Operator
Option.

Step Display/Result

DIGITAL OPERATOR JVOP-182 ALM

1. Turn on the power to the drive. The initial display appears. REV DRV
DRV FOUT

2. Press ・ to select the Parameter Setting and

Press .

3. Press ・ ・ to select o3-01 (Copy Function

Selection) and press .

4. Press ・ to select 01.

5. Press and the LED Operator Option will read parameter


settings from the drive.

6. Automatically return to the Copy Function Selection display.

DIGITAL OPERATOR JVOP-182 ALM

7. Press repeatedly until the display returns to the initial REV DRV
DRV FOUT

display.

YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual 23
7 Related Parameters

7 Related Parameters
Parameters related to the use of the LED Operator Option are listed below. Set these
parameters as needed for the application.
The symbol “{” in the J1000 column indicates this parameter No. applies to the J1000
drive. The symbol “{” in the A1000, V1000 column indicates this parameter No. applies to
A1000 and V1000 drives.
Table 8 Related Parameters

Drive
No. Name A1000x Description Default
J1000
V1000
Selects the source of the frequency reference.
0: Operator -Digital preset speed d1-01 to d1-17
Frequency
1: Terminals - Analog input terminal A1 or A2
b1-01 Reference { { 2: MEMOBUS/Modbus serial communications
1
Selection 1
3: Option PCB
4: Pulse Input (Terminal RP) <1>
Selects the run command input source.
0: Operator -RUN and STOP keys on the LED
Run Command Operator Option
b1-02
Selection 1 { { 1: Digital input terminals S1 to S7
1
2: MEMOBUS/Modbus serial communications
3: Option PCB <1>
Selects the frequency reference input source.
0: Operator - Digital preset speed d1-01 to d1-17
Frequency 1: Terminals - Analog input terminal A1 or A2
b1-15
Reference 2
× { 2: MEMOBUS/Modbus serial communications
0
3: Option PCB
4: Pulse Input (Terminal RP)
Selects the Run command input source.
0: Operator - RUN and STOP keys on the LED
Run Command Operator Option
b1-16
Source 2
× { 1: Digital input terminals S1 to S7
0
2: MEMOBUS/Modbus serial communications
3: Option PCB
LOCAL/ Enables/Disables the LED Operator Option LOCAL/
REMOTE Key REMOTE key.
o2-01
Function
× { 0: Disabled
1
Selection 1: Enabled
Enables/Disables the operator panel STOP key when
STOP Key the drive is operated form external sources (not
o2-02 Function { { operator). 1
Selection 0: Disabled
1: Enabled

24 YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual
7 Related Parameters

Drive
No. Name A1000x Description Default
J1000
V1000
Selects if the ENTER key press is required when
inputting the frequency reference by the operator
Frequency
keypad.
Reference
o2-05
Setting Method { { 0: Data/Enter key must be pressed to enter a 0
frequency reference.
Selection
1: Data/Enter key is not required. The frequency
reference is adjusted by the up and down arrow keys.
Operation Sets drive action when the LED Operator Option is
Selection removed in LOCAL mode or with b1-02 = 0.
o2-06 when LED { { 0: The drive will continue operation. 0
Operator Option 1: The drive will trigger a fault (oPr) and the motor
is Disconnected will coast to stop.
This parameter controls the copying of parameters to
and from the LED Operator Option.
0: COPY SELECT (no function)
1: All parameters are copied from the drive to the
LED Operator Option.
2: All parameters are copied from the LED Operator
Copy Function
o3-01
Selection { { Option to the drive. 0
3: Parameter settings in the drive are compared to
those in the LED Operator Option.
Note: When using the copy function, the drive model
number (o2-04), software number (U1-14), and
control method (A1-02) must match or an error will
occur.
Enables or disables reading of drive parameter
settings.
o3-02 Copy Allowable { { 0: Disabled - Read not allowed
0
1: Enabled - Read allowed

<1> b1-01 = 4 and b1-02 = 3 are not compatible with the J1000 drive.

YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual 25
8 LED Operator Option Fault Diagnostics

8 LED Operator Option Fault Diagnostics


◆ Error Code and Connection Messages
Fault/Error code text will appear on the LED Operator (JVOP-182) display to indicate a
specific fault. The fault codes in Table 9 are displayed on the LED operator built in the drive
and/or the LED Operator (JVOP-182) displays. For information on the fault codes not listed
in Table 9, refer to the drive technical manual.
When an LED Operator (JVOP-182) fault occurs, ensure that the communication cable is
properly connected to the LED Operator (JVOP-182) and it is not loose.
Contact your nearest Yaskawa representative or sales department if the cable appears to be
connect properly but still no message appears to indicate the error.
Table 9 Fault/Error Code Displays

LED Operator LED Operator Description


(JVOP-182) (Drive built-in)
LED Operator (JVOP-182) Communication Error 1
<1>
Occurs when the drive cannot communicate with the
LED Operator (JVOP-182) within 5 seconds after the
power is switched on.
Cause Possible Solution
Communication cable between the LED
Remove the LED Operator (JVOP-182) and then
Operator (JVOP-182) and the drive is not
reconnect it again.
properly connected.
Problem with the LED Operator (JVOP-182). Replace the LED Operator (JVOP-182).
• Cycle power to the drive.
Problem with the control circuit in the drive.
• Replace the drive.
LED Operator LED Operator
Description
(JVOP-182) (Drive built-in)
LED Operator (JVOP-182) Communication Error 2
<1> Occurs if the drive does not respond to the LED
Operator (JVOP-182) for over 2 seconds.
Cause Possible Solution
Connector on the LED Operator (JVOP- Remove the LED Operator (JVOP-182) and then
182) cable is loose or damaged. reconnect it again.
Problem with the LED Operator (JVOP-
Replace the LED Operator (JVOP-182).
182).
• Cycle power to the drive.
Problem with the control circuit in the drive.
• Replace the drive.

26 YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual
8 LED Operator Option Fault Diagnostics

LED Operator LED Operator


Description
(JVOP-182) (Drive built-in)
LED Operator Option Connection Fault
Data should appear on the LED operator built in the
drive. By reconnecting the LED operator (JVOP-182) to
the drive, data should also appear on the LED Operator
(JVOP-182) display.
An oPr fault will occur if all of the following conditions
are true:
Output is interrupted when the LED Operator (JVOP-
182) is disconnected (o2-06 = 1).
The run command is assigned to the LED Operator
(JVOP-182) (b1-02/b1-16= 0 and LOCAL is selected).
Cause Possible Solution
• Check the connection between the LED Operator
(JVOP-182) and the drive.
LED Operator (JVOP-182) is not properly • Replace the cable if damaged.
connected to the drive. • Turn off the drive input power and disconnect the LED
Operator (JVOP-182). Reconnect the LED Operator
(JVOP-182) and reapply drive input power.
<1> Display will vary depending on operation status.

YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual 27
9 Specifications

9 Specifications
Table 10 LED Operator Option Specifications

Model JVOP-182
Connector RJ-45
Power Supply Powered from the drive (DC +5 V ±5%)
Operating
-10 to +50 °C
Temperature
Humidity up to 95% RH (no condensation)
-20 to +60 °C
Storage Temperature
(allowed for short-term transport of the product)
Area of Use Indoor (free of corrosive gas, airborne particles, etc.)
Altitude Up to 1000 m
10 to 20 Hz : 9.8 m/s2
Shock
20 to 55 Hz : 5.9 m/s2
Read Function
Estimated 100,000 times
Limitation

28 YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual
10 Revision History

10 Revision History
The revision dates and numbers of the revised manuals are given on the bottom of the back
cover.

MANUAL NO. TOBP C730600 35A


Published in Japan September 2008 08-3 1
Revision number
Date of Date of original
publication publication

Date of Rev. No. Section Revised Content


Publication
March 2008 − − First edition
September 2008 1 Back cover Revision: Address
December 2008 2 All chapters Revision: Application to the A1000 drive and V1000 drive

YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual 29
YASKAWA AC Drive Option
LED Operator
Installation Manual

IRUMA BUSINESS CENTER (SOLUTION CENTER)


480, Kamifujisawa, Iruma, Saitama 358-8555, Japan
Phone 81-4-2962-5696 Fax 81-4-2962-6138
YASKAWA ELECTRIC AMERICA, INC.
2121 Norman Drive South, Waukegan, IL 60085, U.S.A.
Phone 1-847-887-7000 Fax 1-847-887-7370
YASKAWA ELETRICO DO BRASIL LTDA.
Avenida Fagundes Filho, 620 Sao Paulo-SP CEP 04304-000, Brazil
Phone 55-11-3585-1100 Fax 55-11-5581-8795
YASKAWA ELECTRIC EUROPE GmbH
Hauptstraβe 185, 65760 Eschborn, Germany
Phone 49-6196-569-300 Fax 49-6196-569-398
YASKAWA ELECTRIC UK LTD.
1 Hunt Hill Orchardton Woods Cumbernauld, G68 9LF, United Kingdom
Phone 44-1236-735000 Fax 44-1236-458182
YASKAWA ELECTRIC KOREA CORPORATION
7F, Doore Bldg. 24, Yeoido-dong, Youngdungpo-Ku, Seoul 150-877, Korea
Phone 82-2-784-7844 Fax 82-2-784-8495
YASKAWA ELECTRIC (SINGAPORE) PTE. LTD.
151 Lorong Chuan, #04-01, New Tech Park 556741, Singapore
Phone 65-6282-3003 Fax 65-6289-3003
YASKAWA ELECTRIC (SHANGHAI) CO., LTD.
No.18 Xizang Zhong Road. Room 1702-1707, Harbour Ring Plaza Shanghai 200001, China
Phone 86-21-5385-2200 Fax 86-21-5385-3299
YASKAWA ELECTRIC (SHANGHAI) CO., LTD. BEIJING OFFICE
Room 1011A, Tower W3 Oriental Plaza, No.1 East Chang An Ave.,
Dong Cheng District, Beijing 100738, China
Phone 86-10-8518-4086 Fax 86-10-8518-4082
YASKAWA ELECTRIC TAIWAN CORPORATION
9F, 16, Nanking E. Rd., Sec. 3, Taipei, Taiwan
Phone 886-2-2502-5003 Fax 886-2-2505-1280

YASKAWA ELECTRIC CORPORATION

YASKAWA

In the event that the end user of this product is to be the military and said product is to be employed in any weapons systems or the manufacture
thereof, the export will fall under the relevant regulations as stipulated in the Foreign Exchange and Foreign Trade Regulations. Therefore, be sure
to follow all procedures and submit all relevant documentation according to any and all rules, regulations and laws that may apply.
Specifications are subject to change without notice for ongoing product modifications and improvements.
© 2008 YASKAWA ELECTRIC CORPORATION. All rights reserved.

MANUAL NO. TOBP C730600 35B


Published in Japan December 2008 08-3 2 -0