Professional Documents
Culture Documents
MODEL FCV-582L
9-52, Ashihara-cho,
Nishinomiya, Japan
Te l e p h o n e : 0 7 9 8 - 6 5 - 2 111
Te l e f a x : 0798-65-4200
WARNING WARNING
ELECTRICAL SHOCK HAZARD Keep heater away from equipment.
Do not open the equipment.
A heater can melt the equipment’s power
Only qualified personnel cord, which can cause fire or electrical
should work inside the shock.
equipment.
Use the proper fuse.
Immediately turn off the power at the
switchboard if water leaks into the Use only a 3A fuse. Use of a wrong fuse
equipment. can result in equipment damage and void
the warranty.
Continued use of the equipment can cause
fire or electrical shock. Contact a FURUNO
agent for service.
i
i
OPTIONAL MODE
2.1 Displaying the Optional Mode Menu .. 15
2.2 System Menu ....................................... 15
2.3 Demonstration Display ........................ 17
2.4 Bottom Level ....................................... 17
2.5 TVG Level ........................................... 18
2.6 Echo Offset .......................................... 18
ii
Downloaded from www.Manualslib.com manuals search engine
FOREWORD
iii
DEMO ( )
iv
DISPLAY
UNIT
Ship's mains
12–24 VDC
External equipment
(GPS navigator, etc.)
Speed, temperature
sensor (option)
TRANSDUCER
vi
SHIFT
• Shift display range.
(p. 7)
• Select menu options.
(p. 10)
• Shift VRM. (p. 9)
MARKER
• Select menu items. (p. 10)
ADVANCE
Selects zoom mode. (p. 3) Removes weak echoes.
ZOOM SIG LEV (p. 9)
Selects picture advance
A-SCOPE
speed. (p. 8)
Adjusts display brilliance Sets alarms. (p. 12)
and tone. (p. 3) BRILL ALARM
Turns A-scope
4 5 display on/off. (p. 10)
3 6
2 7
1 8
RANGE Selects range. (p. 7)
4 6
PUSH
AUTO
2 8
0 10
• Rotate to adjust gain. (p. 7) GAIN
• Push to turn automatic DUAL
operation on/off. (p. 7) LF HF
ZOOM ZOOM
Removing cover NAV MENU
MODE Selects display mode.
While pressing the center
(p. 3)
of the cover with your
thumbs as illustrated, pull POWER Turns power on/off.
the cover towards you to (p. 3)
remove it.
Speed*
Noise Limiter
Transducer frequency
Alarm icon
Color
bar 0
60
All indications and
markers are displayed
Demonstration (DEMO) in white unless
mode
49.6 80
noted otherwise.
Note: Wait at least five sec. before reapply- Figure 1-5 Zoom mode selection display
ing the power.
Normal display
1.4 Adjusting Tone and Brilliance Low frequency (50 kHz) display
1. Press the BRILL key. The tone and bril- The sounder uses ultrasonic pulses to detect
liance setting display appears. bottom conditions. The lower the frequency
of the pulse, the wider the detection area.
LOW– +HIGH Therefore, the 50 kHz frequency is useful for
TONE : 5 general detection and judging bottom condi-
LOW▼ ▲HIGH
tion.
BRILL : 7
0
49.6 80 15
Normal
display
Figure 1-7 Typical 50 kHz display 10
14.7 Variable range
High frequency (200 kHz) display Fish marker (green)
school
20 This section
The higher the frequency of the ultrasonic 20
is zoomed
pulse the better the resolution. Therefore, the Zoomed fish
school
200 kHz frequency is ideal for detailed ob-
30
servation of fish schools.
25
Dual-frequency display 28.2
The 50 kHz picture appears on the left; the Zoom marker
200 kHz picture on the right. This display is Marker-zoom (yellow)
display
useful for comparing the same picture with
two different transmitting frequencies. Figure 1-9 Marker-zoom display
plus normal display
50/200
0 0.0 0
Note : The zoom marker looks like white
50 kHz 200 kHz when the background is blue.
picture picture
20 20
40 40
60
49.6 80
20
Bottom-zoom display
2
0
Bottom- 1 30
15 lock
display
10 0
20.7 40
20
20 Zoom Normal
marker display
(yellow)
30 Figure 1-11 Bottom-lock display plus
normal display
25 Note: The zoom marker is not displayed in
36.4 40 the default setting. It may be turned on in Sys-
tem menu 1. For further details see page 15.
Bottom
Normal
display Data display
Figure 1-10 Bottom-zoom display plus This display provides navigation data in digi-
normal display tal form. Date, time, position, course, speed,
depth, water temperature and waypoint data
Bottom-lock display can be shown. Requires nav data input and
appropriate sensors.
The bottom-lock display provides a com-
pressed normal picture on the right half of the POS 0
screen and a 5 or 10 meter (10 or 20 feet) wide Position 30°00. 065’N
layer in contact with the bottom is expanded
onto the left half of the screen. This mode is 130°00. 574’E 20
useful for bottom discrimination. CSE SPD
Course, speed
143° 15. 6kt
40
DEP TMP
Depth,
temperature 69. 4m 9. 3°C
Waypoint WP ABC 60
Range to waypoint RNG 12nm
Bearing to waypoint BRG 123. 4°
Cross-track error XTE 1. 23nm 80
indications as follows:
Bearing Course
BRG
W 248° E indicator
1. Press the [▲] or [▼] key to select the in- 20
Course CSE
dication you want to display. A blue cur- 323°
1nm 1nm
sor circumscribes your selection. For XTE
example, select the waypoint data win- 40 scale
Waypoint WP SPD Speed
dow.
ABC 16.8 kt
2. Press the [+] key to enlarge the data. Range to RNG TRIP
60
Trip
waypoint 12.0 nm 76.8 nm distance
WP 0 Depth DEP TMP
RNG 20 Temperature
Range shifting
1.6 Selecting Display Range The basic range may be shifted with the [+]
and [–] keys. The shift display window, which
The basic range and range shifting functions appears when the [+] or [–] key is operated,
used together give you the means to select the shows current shift amount. Note that the
depth you can see on the screen. The basic SHIFT keys and RANGE control are inop-
range can be thought of as providing a “win- erative in automatic operation.
dow” into the water column and range shift-
ing as moving the “window” to the desired
SHIFT 0m
depth. Note that the RANGE control is inop-
erative in automatic operation. (See the next
Figure 1-17 Shift display
page for details.)
Note: The maximum shift range is 2500 feet
(500 m). However, the actual range will de-
pend on underwater conditions. In the worst
case echoes will not appear.
Shift
AUTO MODE
▲ OFF
CRUISING
▼ FISHING
Weak
echoes
Signal level
adjusted
10
11
12
← Arrow points to
color currently
displayed in white.
13
15
16
DEMO MODE
OFF ON
- +: To set condition
▼: OPTIONAL MODE
17
18
Second bottom
Small Large
school echo
school
Size of
fish school
Rock base
Mud
Figure 3-2 Fish school echoes and sand
19
20
21
22
GRAY
BLACK
ROM:OK
RAM:OK
RANGE: 2
GAIN : 86 WHITE
WHITE
MODE : 4
** = Version no.
Y P
Figure 4-1 Test display B G
B E U A
W
L R R H
L L R Q
3. The ROM and RAM are checked and the A E E
U L P U
I
C D E T
results are displayed as OK or NG (No K E O L A
N E
Good). W E
4. Press and release each key (except the Figure 4-2 Test patterns
POWER key) one by one. If the key is
normal, its on-screen location lights in 3. Press the POWER key to escape.
black and the buzzer sounds while the key
is pressed.
5. Operate the controls. The control setting
indication should be the same as actual
control setting.
23
+: YES
–: NO
24
This equipment is a dual-frequency (50/200 kHz) color LCD video sounder which has a large variety of
functions, all contained in a splash-proof rugged diecasting aluminum case that is compact to fit small
boats.
1. GENERAL
(1) Transmit Frequency 50 kHz/200 kHz
(2) Output Power 600 Wrms
(3) Tx Rate 1500 pulse/min max.
(4) Pulselength 0.13 to 3.6 ms
(5) Transducer Dual-frequency one-mold type
2. DISPLAY UNIT
(1) Indication System 6.5-inch color TFT LCD
(2) Echo Colors 8 or 16 colors depending on echo intensity.
Monochrome presentation is also available.
(3) Display Mode Normal (high/low), Combination display, Marker zoom, Bottom zoom,
Bottom-lock expansion
(4) Alphanumeric Data Digital display of water depth, *Water temperature,
*Ship’s speed/position data
*: Speed/temperature sensor is required.
(5) Basic Display Range
Unit Range Range Setting
1 2 3 4 5 6 7 8
Meters 5 10 20 40 80 150 300 800 2 to 800
Feet 15 30 60 120 200 400 1000 2500 7 to 2500
Fathoms 3 5 10 20 40 80 150 400 1 to 400
Passi/Braza 3 5 10 30 50 100 200 500 1 to 500
(6) Range Shift 0 to 800 m, 0 to 2500 ft, 0 to 400 fa or 0 to 450 p/b
(7) Expansion Range Bottom lock expansion: 5/10m
Target lock expansion: 2 m to 800 m
(8) Picture Advance Speed 7 steps (Lines/Tx: freeze,1/16,1/8,1/4,1/2,1/1,2/1)
(9) User Setting Interference rejecter, Clutter, Alarm, Sensitivity, Hue level, Sensitivity
SP - 1
4. POWER SUPPLY
(1) Voltage and Current 12 - 24 VDC: 1.5 - 0.5 A
6. ENVIRONMENTAL CONDITION
(1) Temperature -15 °C to +55 °C
(2) Relative Humidity 95% or less at 40 °C
(3) Waterproofing IEC IPX5
(4) Category of Equipment Units
Display Unit: To be installed in a protected area
7. COATING COLOR
(1) Display Unit Panel: N3.0 Newtone No.5
Chassis: 2.5GY5/1.5
SP - 2
A M
A-scope display 10 Marker-zoom display 4
ALARM key 12 Menu tree iv
Alarm zone width 12 MODE control 3
Automatic operation 8
N
B
Nav data enlargement 6
Basic range setting 16 Nav display selection 16
Bearing reference 16 Noise limiter 11
Bottom alarm 12
Bottom echo 19
O
Bottom level 17 Optional mode 15
Bottom-lock display 5
Bottom-lock range 17 P
Bottom-zoom display 5 Picture advance speed 8
BRILL key 3 POWER key 3
Brilliance 3 Power on/off 3
C R
Cleaning 21 RANGE control 7
Clutter 11
Colors 11 S
Control description 1
SHIFT keys 7
D SIG LEV key 8, 9
Specifications 25
Data display 6 Speed indication offset 16
Demonstration display 17 Speed input 16
Depth unit 16 Speed unit 16
Dual-frequency display 4 Surface noise/aeration 20
E System configuration v
System menu 15
Echo offset 18
T
F
Test 23
Fish alarm 12 Test pattern 23
Fish alarm level 16 Tone 3
Fish school echoes 19 Transducer maintenance 21
Fuse replacement 21 Trip distance resetting 6
G Troubleshooting 22
TVG level 18
GAIN control 7, 8 Tx output 16
Graphic display 6
U
I
User menu 10
Indications 2
Input format 16 V
VRM 9
Index-1
Downloaded from www.Manualslib.com manuals search engine
W
Water temperature alarm 12
Temperature graph 16
Temperature indication offset 16
Temperature input 16
Water temperature unit 16
White marker 13
Z
Zero line 19
ZOOM key 3, 8
Zoom marker 16
Zoom range 17
Index-2
Downloaded from www.Manualslib.com manuals search engine