SEQUENTIAL CONTROLLER
Features
1 Digital Display, provides ease of operation and
clear display of operation status.
1 Microprocessor: Accurate and precise
operation.
1 Remote Control: Convenient control through
remote means.
1 Able to automatically execute the pulse jet
cycle even after the system shuts down so as
to prevent residue sticking unto cloth filter.
1 Option: Water-proof and dust-proof enclosure,
to extend lifespan of the controller.
FlneTek
PANEL AND TERMINAL DIAGRAM Programmable Sequential Controller
*AE110A *AE120A
AC06 COM
AC10
FlneTek
AC02
6 AC14 6
AC08
4 FAN.A AC17
AC18
ON
6 AC19
AC2 3
1 AC1
AC20
OFF
COM
COM
JS1
220V 110V AC05
AC04
5 R.C A
6 AC03
220V
2 AC02
110V 4 FAN.A AC01
ON
Solenoid
1
AC2
3 valve
AC1
OFF
2 220V
110V
*AE140A 6
AC28
COM
The Controller is able to select AC110V or 220V.
6 AC29
AC20
AC19
AC30
AC18 6 2 Power supply selection: (JS1)
COM
AC17 Please select the power supply AC 110V or 220V
AC16
AC31
COM 3 Power switch
AC32
AC15
6
AC33
AC14 6
AC34 4 Fan control input: (FAN.A)
AC13
AC35 FlneTek
AC12
This function is used to complete Auto-Shut-Off cleaning
COM
AC11 cycle before controller stopped. When this contact is
AC36 closed, controller running regulary. When this contact is
AC37 open, controller will run Auto-Shut-Off cleaning cycle
COM
6
AC38
AC10
(defined by "CLC" setting). This function is purposed to
AC39
AC09
prevent dust clogged on the bag.
AC40
COM AC08 6
AC07
5 Remote control input: (R.C.A)
...
AC06
5 R.C A
COM If remote control is required, please remove the short
4 FAN.A AC05 circuit, then, extend the wiring to remote site. When the
6
AC04 remote input is open circuit, the controller will stop
AC2 3 AC03
operation, when the remote input closed circuit, the
1 AC02
AC1 controller resumes normal working operation.
AC01
2
FlneTek
PROGRAM SETTING Programmable Sequential Controller
Running
Mode
Upper Display
Increase ENTER
FlneTek
XXX XXX XXX XXX XXX
SHIFT
XXX XXX XXX XXX XXX
3
FlneTek
SPECIFICATIONS / DIMENSIONS Programmable Sequential Controller
Controller
1 Dimensions
74.8 86.1
7-f4.2
78.0
73.4
107.2
106.2 48.2
140 160
82.6 240.0
106.4
137.7
108.5
38.0
70.6 70.0
10-f4.2
106.2 54.7
116.1
*CASE (Optional)
54.8 Material: ABS
Dimension: 230x300x86.5mm
10-f4.2
97.9 83.8
4
FlneTek
TROUBLESHOOTING Programmable Sequential Controller
5
FlneTek
PANEL AND TERMINAL DIAGRAM Sequential Controller
1 Connections
1. Power Supply Selection
Á is used for selection of power supply, factory
default is set at 220V. If the power supply is 110V,
just transfer the jumper connection from 220V
end to 110V end.
2. Wiring
A. Live wire of the power supply must be connected to
L1 terminal, the neutral wire must be connected to
L2 terminal.
B. Common wire of solenoid must be connected to
COM terminal whereas the others are connected
to their respective terminals 1~10.
C. Remote control à is used for long distance control
or cascading control. If neither of these controls are
required, do not remove the shorting metallic strip
at terminals P1 and P2.
2
SER NO:
20
14 48 55 165 4. Interval adjustable
Adjust À to the value required for the time delay
2
8 54 40 185
2 60 20 200
3 SECONDS MILLISECONDS
5
6 7
6
5. Spray time adjustable
7
Adjust  to the value required for how long the
8
solenoid valves remain in operation
9
10
ON
5 6. After the various settings are done, please start
2 3 4 5 6 7 8 9
STEP Switch
operation by switching on the power supply.
6
FlneTek
PANEL AND TERMINAL DIAGRAM Sequential Controller
4 Interval adjustable
1 2
Adjust À to the value required for the time delay
between each individual valve operations.(2~60 s)
3
ON
PILOT AEA-0040 2 3 4 5 6 7 8 9
VALVES
7
SPECIFICATIONS / DIMENSIONS Sequential Controller
Controller electrical
1 Specifications
1 Dimensions
* AE410A * AE520D
113 103
98 M4x4 87
M4x4
152
162
136
149
1 Optional
*CASE
Material: Cover--- PC
Box------ ABS
146
133
CASE
186
173
75
8