You are on page 1of 14

GE Medical Systems – Americas: 888-202-5528

P.O. Box 414, Milwaukee, Wisconsin 53201 U.S.A.


GE Ultrasound - Europe: +49-212-28020
P.O. Box 1105 60 D-42665 Solingen
GE Ultrasound - Asia: 65-291-8528
Singapore: 298 Tiong Bahru Road, #15-01/06
Tiong Bahru Plaza, Singapore 168730
Internet: http://www.gemedicalsystems.com
Preliminary

Product Data
Rev. H
LOGIQ P5
18 July 2006 TruScan Imaging Technology

Product Description • Urology Probe Holder(Optional)


• Drawer(Optional)
• Probe Cable Hanger(Optional)
The LOGIQ P5 is an ergonomic, highly
• Urology Probe Holder(Optional)
mobile and easy to use high performance
multipurpose imaging system designed for
Obstetrics, Gynecology, Cardiology, User Interface
Musculoskeletal, Vascular, Urological, Operator Keyboard
Small Parts, Superficial, Pediatric, • Keyboard Width: 43cm
Neonatal, Transcranial, and Abdominal Keyboard Height: 84/90cm
applications. • Alphanumeric Keyboard
• Ergonomic Hard Key Operations
System Architecture • Indicator Lights Identify Activated Keys
• Integrated Recording Keys for Remote
TruScan Architecture – our exclusive,
Control of Up to 2 Peripheral Devices
software-intensive ultrasound imaging
and DICOM Devices
platform that gives you unsurpassed
• 8 TGC Pods, with Re-mapping
computational power, image-manipulation
Functionality at Any Depth
capability, workflow flexibility and
product upgrade-ability, via software or
Monitor
hardware.
• 15 inch TFT LCD
• XGA Format:
TruAccess is the new, GE-exclusive,
Electrical Power - Display size: 1024 x 768
raw-data processing technology that will
• Voltage: 100-120Vac or 220-240Vac - Recording area: 800 x 600
change the future of ultrasound imaging.
• Frequency: 50/60 Hz • Adjustable Tilt/Swivel
By accessing raw data, TruScan achieves
• Power: Max. 750 VA with Built-in and • Digital Brightness/Contrast Adjustment
excellent image quality and ensures
On-Board Peripherals
unsurpassed today’s image management System Overview
• Maximum Thermal Output: 2200
tomorrow.
BTU/hr.
Applications
SmartScan utilizes new advances in • Abdominal
Console Design
operating algorithms and system • Obstetrical
• 2 Active Probe Ports(Optional 3 Ports)
operations to improve image acquisition • Gynecological
• Integrated HDD (Capacity : 80G)
and patient throughput while increasing • Cardiac
• Integrated DVD-R/W Drive
diagnostic confidence and exam • Musculoskeletal
• On-board Storage for Peripherals(Max 3
consistency. • Vascular
peripherals)
- B/W-printer, color printer, DVD • Urological
ComfortScan, our most advanced • Small Parts and Superficial
recorder
ergonomic design ever, helps maximize • Pediatric and Neonatal
• Wheels
productivity and simplify every exam you • Transcranial
- Wheel diameter: 12.5cm
perform.
- Integrated locking mechanism that
provides rolling lock and optional caster Scanning Methods
General Specification swivel lock • Electronic Sector
• Probe Holders, Removable for Cleaning • Electronic Convex
Dimensions and Weight and Washing • Electronic Linear
• Height: 135/141 cm • Gel Holder, Removable for Cleaning and
• Width: 43cm Washing
• Depth: 64cm • Air Filters, Easily Removable
• Weight: approx. 75 kg (165 lb.) • Front Handle
• Rear Handle (Optional)

LOGIQ P5 Page 1 of 14
Transducer Types • DICOM 3.0 Connectivity - Independent Dual B/PW Display
• Sector Phased Array • InSiteTM Capability - Display Formats:
• Convex Array • ECG Top/ Bottom or Side/ Side selectable
• Microconvex Array • Coded Contrast Imaging Format Size: (able to switch after
• Linear Array • CW Doppler freeze)
• Doppler Pencil • Anatomical M-Mode - Vertical: 1/3, 1⁄2, 2/3
• LOGIQView - Horizontal: 1⁄4, 1⁄2
Operating Modes • Crossbeam - Full: Time line only
• B-Mode • SRI - Update mode: timed based on sweep
• M-Mode • B-Flow • Virtual Convex
• Optional AMM • Easy 3D (Baby Face, Vascular) • Quad Screen Display
• Color Flow Mode (CFM) • Advanced 3D, with 3D Landscape
• Power Doppler Imaging (PDI) with • 4D Display Annotation
Directional Map • 3-Pedal Foot Switch, with • Institution/Hospital Name: 25 Characters
• PW Doppler with High PRF Programmable Functionality • Date: 3 types selectable
• Optional Crossbeam YY/MM/DD, MM/DD/YY,
• Optional SRI Media & Peripheral Options DD/MM/YY
• Optional B-Flow • Integrated Mounting Kits and Remote • Time: 2 types selectable
• M-Color Flow Mode Controls Provided for 24 hours, 12 hours
• Optional Steerable CW Doppler - B/W Digital thermal printer • Operator Identification
• Optional Dedicated CW Doppler - Color A6 Digital thermal printer • Patient Name: First, Last & Middle
- Color A5 Digital thermal printer name each store 31 characters. Up to 31
System Standard Features - DVD Video Recorder total characters displayed
• Hard Disk for image storage • Patient Identification: 31 Characters
• Without compression: Display Modes • Gestational Age from
• Raw DICOM: > 14500 images • Simultaneous Capability LMP/EDC/GA/BBT
• DICOM: - B/PW • Power Output Readout
- Image Only: > 16,000 images - B/CFM or PDI - MI: Mechanical Index
• 970 Frames (60 sec) CINE Memory - B/M - TIS: Thermal Index Soft Tissue
(192MB) - B/MCFM - TIC: Thermal Index Cranial (Bone)
• Real-time Triplex Mode at any Depth - Real-time Triplex Mode - TIB: Thermal Index Bone
and PRF (B + CFM or PDI/PW) • System Status (real-time or frozen)
• Automatic Optimization - Dual B (B/B) • Probe Orientation Marker: Coincides
- Auto Tissue Optimization: ATO - Dual B + CFM or PDI with a probe orientation marking on the
- Auto Spectrum Optimization: ASO • Selectable Alternating Modes probe.
- Auto Color Optimization: ACO - B/M • Image Preview
• ACETM - B/PW • Gray/Color Bar
• Tissue Harmonics - B + CFM (PDI)/M • Cine Gauge
• Virtual Convex - B + CFM (PDI)/PW • Measurement Summary Window
• Patient Information Database - 3D – Mode (option) • Measurement Results Window: pre-
• Image Archive on Hard Drive and DVD - 3D – Color Mode (option) settable display location
• Easy Backup for Media • Multi Image Split Screen • Probe Type
• Vascular Calcs - Live and/or frozen • Application Name
• Cardiac Calcs - B + B/CFM or PDI • Imaging Parameters by Mode (current
• OB Calcs - Independent Cine playback mode highlighted)
• Fetal Trending • Zoom: Write/Read/Pan - B/M-Mode
• Multi Gestational Calcs • Colorized Image Imaging Frequency
• Hip Dysplasia Calcs - Colorized B Gain
• Gynecological Calcs - Colorized M Edge Enhance
• Urological Calcs - Colorized PW Frame Averaging
• Renal Calcs Gray Map
• Real-time Auto Doppler Calculations Image Depth
• TruAccess, Raw Data Processing Dynamic Range
• On-board Reporting Line Density
% of Power Output

System Options • Time line Display


LOGIQ P5 Page 2 of 14
- Color Flow Mode (Optional) • CUA/AUA for Hadlock - Wall Filter
Doppler Frequency • Body Pattern Copy to Active Side: - Baseline
Color Gain On/Off - Angle Steer
Line Density • Colorized B/M/D: 6 types for each - Angle Correct
Frame Averaging • Programmable Annotation Library: - Quick Angle Correct
% of Power Output 24 annotations - Auto Angle Correct
PRF • Customized Common Home Position - Doppler Frequency
Wall Filter • Color Printer Memory: 3 types - Doppler Invert
Spatial Filter Single, Quad-Frm, Quad-Frmls - Display Format
Packet Size • Menu Selection at New Patient: 2 types - Sweep Speed
- PW-Mode Patient Entry, Schedule - Full Timeline
Doppler Frequency • Sort Criteria for Schedule List: 2 types - Rejection
Doppler Gain Date&Time, Name - Time Resolution
% of Power Output • Patient Name Format: 2 types - Gray Map
PRF Full Name, Last&First - Colorize
Wall Filter • Auto Deletion of Transferred Queue: - Dynamic Range
Sample Volume Width Yes/No - CFM/PWD Ratio
Dynamic Range • Pre-settable Doppler Audio Volume - Duplex
Sample Volume Depth • Measurement Clear Operation: 2 types - Auto Calcs
Angle Correction Meas.-only, with-Comment - Trace Direction
• Focal Zone Markers • Display Unit Age: 5 types - Modify Calcs
• TGC Curve: On/Off Year, Month, Week, Day, No display - Number of Average Cycles
• Body Pattern: 106 types • System Boot Up: 180 sec - Trace Method
• B Scale Markers: 2 types • Probe Change: 5-8 sec - Trace Sensitivity
Depth/Width & Depth - Auto Optimize (ASO)
• M Scale Markers: Pre-Processing - Audio Volume
Time/Depth • Acoustic Power Output • Color Flow Mode(Optional)
• Image Management Menu: Menu, Delete, • Write Zoom up to 8x - Gain
and Image Manager • B/M-Mode - ROI Position, Size
• Image Palette - Gain - PRF
• Caps Lock: On/Off - TGC - Wall Filter
• System Messages Display - Image Reverse - Baseline
• Trackball Functionality Status: Scroll, - Depth - Angle Steer
M&A (Measurement and Analysis), - Scan Area - Color Line Density
Position, Size, Scan Area Width and Tilt - Auto Optimize (ATO) - Color Frequency
• Biopsy Guide Line and Zone - Dynamic Range - Packet Size
• Heart Rate - Focus Number - Color Invert
- Focus Position - Color Map
System Parameter - Line Density - Threshold
- Frequency - Frame Average
System Setup - Image Rotation - Focus Position
• Diagnostic Categories: 8 types, pre- - Gray Map - ACE
settable - Colorize - Spatial Filter
Abd, Obst, Gyne, Card, Vasc, Urol, - Frame Average - CFM/PWD Ratio
Smlpts, Peda - Edge Enhance - Duplex
• User Programmable Preset Capability - Rejection - Sweep Speed for Color M-Mode
• Factory Default Preset Data - Virtual Convex - Anatomical Color M-Mode
• Languages: English, French, German, - Focus Width • 3D Acquisition
Spanish, Italian, Portuguese, Russian, - Suppression - Scan Distance
Greek, Turkish, Swedish, Danish - B Softener - ROI Style
• Operation Error Beep: Off, Low, Loud - M/D Cursor - Display Format
• Body Surface Area: 2 types - Sweep Speed for M-Mode - Scan Plane
Oriental, Occidental • PW-Mode Front to Back
• OB Report Format: 4 types - Gain Side to Side
Tokyo Univ., Osaka Univ., USA, Europe - Sample Volume Depth
• EFBW: 8 types - PRF
Tokyo Univ., Osaka Univ., USA and
Europe (Shephard, Merz,
Hadlock/Shephard, Williams, Brenner)

LOGIQ P5 Page 3 of 14
- Acquisition Mode • Advanced 3D (option) • 256 Shades of Gray
Parallel - 3D Landscape • Up to 173 dB Processing Dynamic
Sweep - Colorize Range
- Threshold (Opacification) • Adjustable Field of View (FOV)
TruAccess: the new, GE-exclusive, - Re-slice • Image Reverse: Right/Left
raw-data digital processing - Type 1/2 • Image Rotation: 2 steps
• Read Zoom up to 8x - Group Planes Rotation: 0°, 180°
• B/M-Mode - Scalpel
- Gain - Define Axis CINE Memory/Image Memory
- Image Reverse - Visible Data • Typical 970 Frames (60 sec) with
- Auto Optimize (ATO) - Tile Standard CINE Memory (192 MB)
- Compression (Dynamic Range) - Active Data depend on FOV, Scanning Lines etc.
- Image Rotation - Auto Movie • CINE Gauge and CINE Image Number
- Gray Map - Rotate Display
- Colorize - Undo • CINE Review:
- Frame Average (in loop images) - Reset Frame-by-frame, Loop
- Rejection • 3D Movie • CINE Review Speed: 9 types
- Sweep Speed for M-Mode - Colorize 100%, 48%, 31%, 25%, 22%, 17%,
- Anatomical M-Mode - Pause 14%, 13%, 11%
• PW-Mode - Movie Speed • Selectable CINE Sequence for CINE
- Gain - Axis Review
- Baseline - Define Start/End • Start and End Frame Selections for Loop
- Angle Correct - Auto Movie Playback
- Quick Angle Correct - Movie 360° • Frame Protection from Overwrite for
- Doppler Invert - Manual Short Term Storage
- Display Format • Separation Marker to Indicate Time
- Sweep Speed Imaging Processing and Discontinuity
- Full Timeline • Measurements, Calculations and
- Rejection
Presentation Annotations on CINE Playback
- Gray Map TruScan: Software Intensive • Scrolling Timeline Memory
- Colorize Ultrasound Imaging Platform
- Compression (Dynamic Range) • Digital Beamformer Image Archive/Connectivity
- Auto Calcs • 2560 System Processing Channel • Clipboard: displays thumbnail images of
- Trace Direction Technology the acquired data for the current exam
- Modify Calcs • Displayed Imaging Depth: 2 – 30 cm • Previewing Clipboard Images: An
- Number of Average Cycles probe dependent enlarged preview of the image
- Trace Method • Minimum Depth of Field: 2 cm • Recalling Images from the Clipboard
- Trace Sensitivity (Zoom and probe dependent) • Image Browser: Archived images from
- Auto Optimize (ASO) • Maximum Depth of Field: 30 cm past patient exams appear as well as
• Color Flow Mode (probe dependent) images stored for the current exam
- Baseline • Transmission Focus - Previewing an Image
- Color Invert - 1 – 8 Focus Points Selectable (probe - Analyzing Images
- Color Map and application dependent) • Image Management
- Threshold - Focal Zone Position, B-Mode 16 steps, - Select All/Unselect All
- Frame Average (in loop images) CFM 64 steps - Permanent Store
- Sweep Speed for Color M-Mode • Continuous Dynamic Receive - Discard all the Temporary Images
- Anatomical Color M-Mode Focus/Aperture - Delete Selected Image
• Easy 3D (option) • Multi-Frequency/Wideband Technology - Analyze
- Colorize • Hard Drive Image Storage: 25 GB
- Threshold (Opacification) • Ethernet Network Connection
- Mix Type 1 • Configurable 2 Print (Recording) Keys
- Render (P1-P2) to Multiple Output
- Texture Devices/Workflows
- Gray Surface
- Scalpel
- Auto Movie
- Undo
- Reset

LOGIQ P5 Page 4 of 14
• Archiving Format: - Store Color Flow Mode (Option)
- DICOM with ultrasound raw data - Modality Worklist • Base Line: 0 – 100%, 10% step
- Standard DICOM - Multiframe • Invert: On/Off
- Secondary Capture - Storage Commitment • Capture: 4 steps pre-settable
• Capture Area: pre-settable for each print - Modality Performed Procedure Step • CF/PDI Focus Depth: 10 – 100%, 5 %
key (MPPS) step default pre-settable
- Video Area - Media Exchange • CF/PDI ACE: On/Off
- Application Window - Off network/mobile storage queue • CF/PDI Acoustic Output: 0 – 100%,
- Whole Screen - Query/Retrieve 10% step
• Archiving Image Frames: pre-settable - Structure Reporting • PW/CF/PDI Angle Steer: +/- 10°, 20°
for each print key (linear probe)
- Single: stores single frame only Physiological Input Panel (Option) • Packet Size: 6, 8, 10, 12, 14
- Multiple: stores cineloop • Physiological Input OB-Fetal Echo, CARD-Adult, Pediatric
- Secondary Capture: screen shot - ECG, 1 channel 5,6,7,8,10(application, probe dependent)
• Image Compression/Picture Quality: pre- • Dual R-Trigger • Line Density: 5 steps
settable for each print key • Pre-settable ECG R Delay Time • Frame Average: 8 steps
- Quality: 1 to 100% • Pre-settable ECG Position • PRF: 300 Hz – 10400 Hz (probe
• Dataflow: a set of pre-configured • Adjustable ECG Gain Control dependent)
services • Spatial Filter: 6 steps (application
- When you select a dataflow, the Scanning Parameters dependent)
ultrasound system automatically works • Gain: 0 – 40 dB, 0.5 dB step
according to the services associated B-Mode • Wall Filter: 12 – 3000 Hz
with the dataflow • B/M Acoustic Output: 0 – 100%, 2% • Virtual Convex: On/Off
• Configurable Examination List Window, step • Angle/Width (deg, mm): probe
Patient Information Window, and • Image Reverse: On/Off dependent
Search/Create Patient Window • B Color: 8 types • CFM Window Size (depends on probe)
- Free text addresses, birth date, extended • Thermal Index: TIC, TIS, TIB • Convex 10° - 133°
patient dialog in Pts Info window • Softener: 4 steps • Sector 10° - 90°
- Extended search dialog, auto search for • Focus Number: 8 steps • Linear 10 – 46mm
patient in Search/Create Pts window • Compress: 0.5 – 1.5 dB, 0.1 dB step • CF/PDI Frequency: 2 steps
- Pre-defined text directly in Exam List • Line Density: 4 steps • Color Map: 13 types (probe dependent)
window • Noise Suppression: 6 steps • Velocity: 7 types
- Examination list on Archive button • Frame Average: 6 steps • Velocity/Variance: 3 types
- Automatic generation of patient ID • Edge Enhance: 6 steps • Additional: 3 types
- Request acknowledge of End Exam • Angle/Width (deg, mm): probe • Color Threshold: 0 – 100%, 5% step
action dependent, 10 – 133°, 1° step in case of • 24 bits of color (greater than 256 shades)
- Go directly screen from search E8C probe • Auto Line Density: On/Off pre-settable
- Detect unfinished examination • Gray Scale Map: 23 types • CFM/PWD Ratio: 1, 2, 4
• Tools • Gain: 0 – 98 dB, 2 dB step • Accumulation Mode: 8 steps
- Verify DICOM directory on removable • Dynamic Range: 30 – 120 dB, 3 dB step • Symmetrical Velocity Imaging for
media • Harmonic Start: On/Off default pre- optimized 3D color images
- Format removable media (MO disk, settable
rewritable CD) • Virtual Convex: On/Off PDI-Mode (Option)
• Views: shows you an overview of the • Depth: 2 – 30 cm, 1 cm step (probe • PDI Map: 13 types
Ultrasound system’s connectivity dependent) • CF/PDI ACE: On/Off
architecture • Focus Depth: 91 steps default pre- • CF/PDI Focus Depth: 11 steps default
- The currently selected dataflow settable pre-settable
- All configured dataflows • Rejection: 6 steps • CF/PDI Acoustic Output: 0 – 100%,
- The network structure tree • Frequency: 3-4 steps( probe dependent) 10% step
- The configured buttons dataflows • Auto Line Density: On/Off pre-settable • PW/CF/PDI Angle Steer: +/- 10°,20°
• AVI and JPEG Export (linear probe)
• DICOM Support (option)
- Verify
- Print

LOGIQ P5 Page 5 of 14
• Packet Size: 6, 8, 10, 12, 14 • Rejection: 15 steps - 12L
OB-Fetal Echo, CARD-Adult, Pediatric • Gain: 0 – 32 dB, 1 dB step - ERB
5,6,7,8,10 (application, probe dependent) • Wall Filter: 19 – 3000 Hz, 21 steps
• Spatial Filter: 6 steps (probe dependent) • PW/CF/PDI Angle Steer: +/- 10°, 20° Coded Contrast Imaging(option)
• Frame Average: 7 steps • PRF: 640 – 19600 Hz • Available on 3.5C, 3.5CS, 10L, i739 and
• PRF: 300 Hz – 10400 Hz (probe • Sample Volume Depth: 29 steps default t739 probes
dependent) pre-settable • Contrast Clock Display
• Power Threshold: 0 – 100%, 5% step • Time Trigger Scan: 0.3, 0.5 – 10 sec,
• CFM Window Size (depends on probe) Coded Harmonic Imaging 0.5sec step
• Convex 10° - 133° • Available on the following probes: • Coded Harmonic Angio
• Sector 10° - 90° - 3.5C - Tissue Background Selection: 4step
• Linear 10 – 46mm - 3.5CS • TrueAgentDetection
• Gain: 0 – 40 dB, 0.5 dB step - 4C - 2 frequencies on 3.5C, 3.5CS
• Wall Filter: 12 – 3000 Hz - 8C • Coded Phase Inversion
• CF/PDI Frequency: 2 steps - E8C • Phase Inversion
• Auto Line Density: On/Off pre-settable - BE9C • Gray Scale Map: 23 types
• CFM/PWD Ratio: 1, 2, 4 - 8L • Maximum Enhance Mode
- 9L
M-Mode - 10L The LOGIQ P5 is designed for
• Sweep Speed: 8 steps - 12L compatibility with commercially
• M Color: 8 types - i739 available ultrasound contrast agents.
• M/PW Display Format: V-1/3B, V-1/2B, - t739 Because the availability of these
V-2/3B, H-1/2B, H-1/4B, Timeline only - 3S agents is subject to government
• B/M Acoustic Output: 0 – 100%, 2% - 5S regulation and approval, product
step - 7S features intended for use with these
• Rejection: 6 steps - 4D3C-L agents may not be commercially
• Dynamic Range: 30 – 120 dB, 3 dB step • Softener: 4 steps marketed nor made available before
• Edge Enhance: 6 steps • Line Density: 4 steps the contrast agent is cleared for use.
• Gray Scale Map: 23 types • Suppression: 6 steps Contrast related product features are
• M Gain: 0 – 98 dB, 2 dB step • Edge Enhance: 6 steps enabled only on systems for delivery
• Gray Scale Map: 23 types to an authorized country or region of
PW-Mode • Gain: 0 – 98 dB, 2 dB step use. GE Medical Systems makes no
• Maximum and Minimum Velocity • Dynamic Range: 30 – 120 dB, 3 dB claims concerning the safety or
Scales step effectiveness of contrast agents.
- Max: 20 m/sec (angle/probe dependent) • Rejection: 6 steps
- Min: 10 cm/sec • Auto Line Density: On/Off pre -settable LOGIQView
• Gray Scale Map: 4 types • Frequency: Up to 4 steps, depend on • Available on the following Probes:
• Dynamic Range: 24 – 48, 4 dB step probe - 3.5C
• Base Line: 0 – 100%, 10% step - 3.5CS
• SV Gate: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 12, B-Flow (option) - 4C
14, 16 mm • Available on the following probes: - E8C
• Angle Correct: +/- 90°, 1° step - 8L - 8C
• Spectral Color: 5 types - 9L - BE9C
• PW Sweep Speed: 8 steps - 10L - 3S
• Invert: On/Off - i739 - 5S
• M/PW Display Format: V-1/3B, V-1/2B, - t739 - 7S
V-2/3B, H-1/2B, H-1/4B, Timeline only • Image Reverse: left/right - ERB
• Duplex: On/Off • Sensitivity/PRI: 10 steps - 8L
• PW Acoustic Output: 0 – 100%, 10% • Background: On/Off - 9L
step • Displayed Dynamic Range: 30 – 120 dB, - 10L
• Spectral Averaging: 4 steps pre-settable 3dB steps - 12L
• Time Resolution: 4 steps • Line Density: 4 steps - i739
• CFM/PWD Ratio: 1, 2, 4 • Frame Averaging: 8 steps - t739
• Gray Scale Map: 23 selectable - 4D3C-L
• Edge Enhance: 6 steps

Coded Excitation
• Available on the following probes:
- BE9C
- E8C - 8C

LOGIQ P5 Page 6 of 14
RealTime 4D (option) • Provides 5 levels of speckle reduction Abdomen and Small Parts
• Acquisition Modes: • Live Side by Side Display Measurements/Calculations
- Realtime 4D M mode • Compatible with all Convex, Linear and • Splenic Length, Width, and Height
- 3D Static B-Mode Sector probes • Aorta Diameter
• Visualization Modes: • Compatible with all imaging modes • Renal Length
- 3D Rendering(diverse surface and • Doppler Abdomen and Renal Artery
intensity projection modes) Exam Calcs
- Sectional Planes (3 Section planes Measurements/Calculations - Acceleration
perpendicular to each other) - Acceleration Time (AT)
• Render Mode: General Measurements/Calculations - Peak Systole (PS), End Diastole (ED),
- Surface texture, Surface Smooth, Mode Measurement or Mid Diastole (MD)
max-, min- and X-ray (average intensity • B-Mode - Pulsatility Index (PI)
projection), Mix Mode of two render - Distance - S/D or D/S Ratio
Modes - Circumference/Area (Ellipse/Trace) - Resistive Index (RI)
• Curved 3 point render start • M-Mode - TAMAX
• 3D Movie - Tissue Depth (Distance) • Thyroid Length, Width, and Height
• Scalpel: 3D Cut tool - Time Interval
• Display Format: - Depth Difference with Time Interval Obstetrics
- Quad: A-/B-/C-Plane/3D and Slope Measurements/Calculations
- Dual: A-Plane/3D • Doppler Mode • Abdominal Circumference (AC)
- Single: 3D or A- or B- or C-Plane - Velocity • Amniotic Fluid Index (AFI) [Moore]
• 4D Volume Frames/sec: - TAMAX, TAMIN, and TAMEAN • Antero-PosteroTrunk Diameter and
max: 30 (Manual/Auto Trace) Transverse Trunk Diameter (APTD-
- Two Velocities with Slope and Time TTD)
Virtual Convex Interval • Antero-PosteroTrunk Diameter by
• Available on the Following Probes - Time Interval Transverse Trunk Diameter (AxT)
- 8L • Biparietal Diameter (BPD)
- 9L Generic Measurement • Crown Rump Length (CRL)
- 10L • B-Mode • Cardio-Thoracic Area Ratio (CTAR)
- 12L - % Stenosis • Estimated Fetal Weight (EFW)
- i739 - Volume • Femur Length (FL)
- t739 - Angle • Fetal Trunk Area (FTA)
- A/B Ratio • Foot Length (Ft)
CrossBeam (optional) - Heart Rate • Gestational Sac (GS)
• Provides Spatial Compounding • M-Mode • Head Circumference (HC)
• Provides 3 or 5 angles of spatial - % Stenosis • Humerus Length (HL)
compounding - A/B Ratio • Length of Vertebra (LV)
• Live Side by Side Display - Heart Rate • Occipitofrontal Diameter (OFD)
• Compatible with PHI and CHI Harmonic • Doppler Mode • Transverse Abdominal Diameter (TAD)
Imaging - PI (Pulsatility Index) • Transverse Cerebellar Diameter (TCD)
• Available on the following probes: - RI (Resistive Index) • Thorax Transverse Diameter (ThD)
- 3.5C - S/D Ratio • Tibia Length (Tibia)
- 3.5CS - D/S Ratio • Ulna Length (Ulna)
- 4C - A/B Ratio • Multi-Gestational Calculations
- 8C - Max PG (Pressure Gradient) - Up to 4 fetuses
- 8L - Mean PG (Pressure Gradient) - Comparison of multiple fetus data on a
- 9L - SV (Stroke Volume) graph and a worksheet
- 10L - CO (Cardiac Output)
- 12L - FV (Flow Volume) OB Worksheet
- i739 - FVO (Flow Volume Output) • Patient Information
- t739 - Heart Rate Fetus Number
- 4D3C-L CUA/AUA Selection

SRI (optional)
• Speckle Reduction Imaging

LOGIQ P5 Page 7 of 14
Fetus Position - Aortic Valve Area Planimetry (AVA Pl Plane, Four Chamber, Method of Disk
Placenta ani met ry) (LVI Dd, LVIDs, LVSd, LVSs)
• Measurement Information - *** ( Trans AVA) - Left Ventricle Stroke Index, Bi-Plane,
AC • Left Atrium Bullet, Method of Disk (LVAd, LVAs)
HC - Left Atrium Diameter (LA Diam) - Interventricular Septum (IVS)
OFD - LA Length (LA Major) - Left Ventricle Internal Diameter (LVI
BPD - LA Width (LA Minor) D)
FL - Left Atrium Diameter to AoRoot - Left Ventricle Posterior Wall Thickness
• Calculation Information Diameter Ratio (LA/Ao Ratio) (LVPW)
EFW - Left Atrium Area (LAA(d), LAA(s)) • Mitral Valve
EFW GP (growth percentile) - Left Atrium Volume, Single Plane, - Mitral Valve Annulus Diameter (MV
FL/BPD Method of Disk (LAEDV A2C, Ann Diam)
FL/AC LAESV A2C ) (LAEDV A4C, LAESV - E-Point-to-Septum Separation (EPSS)
HC/AC A4C) - Mitral Valve Area by Pressure Half
FL/HC • Left Ventricle Time (MVA By PHT)
CI (Cephalic Index) - Left Ventricle Mass (LVPWd, LVPWs) - Mitral Valve Area Planimetry (MVA
- Left Ventricle Volume, Planimetry)
OB Graphs Teichholz/Cubic (LVIDd, LVI Ds) • Pulmonic Valve
• Fetal Growth Curve Graphs - Left Ventricle Internal Diameter - Pulmonic Valve Area (PV Planimetry)
- Normal growth curve, positive and (LVIDd, LVI Ds) - Pulmonic Valve Annulus Diameter (PV
negative standard deviations or - Left Ventricle Length (LVLd, LVLs) Annulus Diam)
applicable percentiles, and ultrasound - Left Ventricle Outflow Tract Diameter - Pulmonic Diameter (Pulmonic Diam)
age of the fetus (LVOT Diam) • Right Atrium
- One measurement per graph - Left Ventricle Posterior Wall Thickness - Right Atrium Diameter, Length (RAD
- Single or Quad views (LVPWd, LVPWs) Ma)
• Fetal Growth Bar Graph - Left Ventricle Length (LV Major) - Right Atrium Diameter, Width (RAD Mi)
- Ultrasound age and gestational age - Left Ventricle Width (LV Minor) - Right Atrium Area (RAA)
- Plots all measurements on one graph - Left Ventricle Outflow Tract Area - Right Atrium Volume, Single Plane,
(LVOT) Method of Disk (RAAd)
Gynecology - Left Ventricle Area, Two - Right Atrium Volume, Systolic, Single
Measurements/Calculations Chamber/Four Chamber/Short Axis Plane, Method of Disk (RAAs)
• Ovary Length, Width, and Height (LVA (d), LVA (s)) • Right Ventricle
• Uterus Length, Width, and Height - Left Ventricle Endocardial Area, Width - Right Ventricle Outflow Tract Area
• Ovarian Follicle Measurements (LVA (d), LVA(s)) (RVOT Planimetry)
- 1 distance - Left Ventricle Epicardial Area, Length - Left Pulmonary Artery Area (LPA Area)
- 2 distances (LVAepi (d), LVAepi (s)) - Right Pulmonary Artery Area (RPA Area)
- 3 distances - Left Ventricle Mass Index (LVPWd, - Right Ventricle Internal Diameter
• Endometrium thickness (Endo) LVPWs) (RVIDd, RVIDs)
- Ejection Fraction, Teichholz/Cube - Right Ventricle Diameter, Length
Cardiac Measurements/Calculations (LVIDd, LVIDs) (RVD Ma)
B-Mode Measurements - Left Ventricle Posterior Wall Fractional - Right Ventricle Diameter, Width (RVD Mi)
• Aorta Shortening (LVPWd, LVPWs) - Right Ventricle Wall Thickness
- Aortic Root Diameter (Ao Root Diam) - Left Ventricle Stroke Index, (RVAWd, RVAWs)
- Aortic Arch Diameter (Ao Arch Diam) Teichholz/Cube (LVIDd, LVIDs, and - Right Ventricle Outflow Tract
- Ascending Aortic Diameter (Ao Asc) Body Surface Area) Diameter (RVOT Diam)
- Descending Aortic Diameter (Ao Desc - Left Ventricle Fractional Shortening - Left Pulmonary Artery (LPA)
Diam) (LVIDd, LVIDs) - Main Pulmonary Artery (MPA)
- Aorta Annulus Diameter (Ao Annulus - Left Ventricle Stroke Volume, - Right Pulmonary Artery (RPA)
Diam) Teichholz/Cubic (LVIDd, LVIDs) • System
- Aorta Isthmus (Ao Isthmus) - Left Ventricle Stroke Index, Single - Interventricular Septum Thickness
- Aorta *** (Ao st junct) Plane, Two Chamber, Method of Disk
• Aortic Valve (LVI Dd, LVIDs, LVSd, LVSs)
- Aortic Valve Cusp Separation (AV Cusp) - Left Ventricle Stroke Index, Single

LOGIQ P5 Page 8 of 14
(IVSd, IVSs) • Pulmonic Valve Vmax)
- Inferior Vena Cava - QRS complex to end of envelope (Q- - Aortic Valve Peak Velocity at Point E
- Pulmonary Artery Diameter (MPA) to-PV close) (AV Vmax)
- Systemic Vein Diameter (Systemic • Right Ventricle - Aorta Proximal Coarctation (Coarc Pre-
Diam) - Right Ventricle Internal Diameter Duct)
- Patent Ductus Arterosis Diameter (RVIDd, RVIDs) - Aorta Distal Coarctation (Coarc Post-
(PDA Diam) - Right Ventricle Wall Thickness Duct)
- Pericard Effusion (PEs) (RVAWd, RVAWs) - Aortic Valve Insufficiency Pressure
- Patent Foramen Ovale Diameter (PFO - Right Ventricle Outflow Tract Half Time (AR PHT)
Diam) Diameter (RVOT Diam) - Aortic Valve Flow Acceleration (AV
- Ventricular Septal Defect Diameter - Right Ventricle Ejection Time (RVET) Trace)
(VSD Diam) - Right Ventricle Pre-Ejection Period - Aortic Valve Pressure Half Time (AV
- Interventricular Septum (IVS) (RVPEP) Trace)
Fractional Shortening (IVSd, IVSs) - Velocity Circumferential Fiber - Aortic Valve Acceleration Time (AV
• Tricuspid Valve Shortening (Vcf) Acc Ti me)
- Tricuspid Valve Area (TV Panimetry) • System - Aortic Valve Deceleration TIme (AV
- Tricuspid Valve Annulus Diameter (TV - Interventricular Septum Thickness Trace)
Annulus Diam) (IVSd, IVSs) - Aortic Valve Ejection Time (AVET)
- Pericard Effusion (PE(d)) - Aortic Valve Acceleration to Ejection
M-Mode Measurements - Interventricular Septum (IVS) Time Ratio (AV Acc Time, AVET)
• Aorta Fractional Shortening (IVSd, IVSs) - Aortic Valve Area according to PHT
- Aortic Root Diameter (Ao Root Diam) • Tricuspid Valve • Left Ventricle
• Aortic Valve - QRS complex to end of envelope (Q- - Left Ventricle Outflow Tract Peak
- Aortic Valve Diameter (AV Diam) to-TV close) Pressure Gradient (VLOT Vmax)
- Aortic Valve Cusp Separation (AV - Left Ventricle Outflow Tract Peak
Cusp) Doppler Mode Measurements Velocity (LVOT Vmax)
- Aortic Valve Ejection Time (LVET) • Aortic Valve - Left Ventricle Outflow Tract Mean
• Left Atrium - Aortic Insufficiency Mean Pressure Pressure Gradient (LVOT Trace)
- Left Atrium Diameter to AoRoot Gradient (AR Trace) - Left Ventricle Outflow Tract Mean
Diameter Ratio (LA/Ao Ratio) - Aortic Insufficiency Peak Pressure Velocity (LVOT Trace)
- Left Atrium Diameter (LA Diam) Gradient (AR Vmax) - Left Ventricle Outflow Tract Mean
• Left Ventricle - Aortic Insufficiency End Diastole Square Root Velocity (LVOT Trace)
- Left Ventricle Volume, Pressure Gradient (AR Trace) - Left Ventricle Outflow Tract Velocity
Teichholz/Cubic (LVIDd, LVI Ds) - Aortic Insufficiency Mean Velocity Time Integral (LVOT Trace)
- Left Ventricle Internal Diameter (AR Trace) - Left Ventricle Ejection Time (LVET)
(LVIDd, LVI Ds) - Aortic Insufficiency Mean Square Root - Cardiac Output by Aortic Flow (AVA
- Left Ventricle Posterior Wall Thickness Velocity (AR Trace) Pl ani met ry, AV Trace)
(LVPWd, LVPWs) - Aortic Insufficiency Velocity Time - Stroke Volume Index by Aortic Flow
- Left Ventricle Ejection Time (LVET) Integral (AR Trace) (AVA Planimetry, AV Trace)
- Left Ventricle Pre-Ejection Period - Aortic Valve Mean Velocity (AV • Mitral Valve
(LVPEP) Trace) - Mitral Valve Regurgitant Flow
- Interventricular Septum (IVS) - Aortic Valve Mean Square Root Acceleration (MR Trace)
- Left Ventricle Internal Diameter (LVI Velocity (AV Trace) - Mitral Valve Regurgitant Mean
D) - Aortic Valve Velocity Time Integral Velocity (MR Trace)
- Left Ventricle Posterior Wall Thickness (AV Trace) - Mitral Regurgitant Mean Square Root
(LVPW) - Aortic Valve Mean Pressure Gradient Velocity (MR Trace)
• Mitral Valve (AV Trace) - Mitral Regurgitant Mean Pressure
- E-Point-to-Septum Separation (EPSS) - Aortic Valve Peak Pressure Gradient Gradient (MR Trace)
- Mitral Valve Leaflet Separation (D-E (AR Vmax) - Mitral Regurgitant Velocity Time
Excursion) - Aortic Insufficiency Peak Velocity (AR Integral (MR Trace)
- Mitral Valve Anterior Leaflet Vmax) - Mitral Valve Mean Velocity (MR
Excursion (D-E Excursion) - Aortic Insufficiency End-Diastolic Trace)
- Mitral Valve D-E Slope (D-E Slope) Velocity (AR Trace) - Mitral Valve Mean Square Root
- Mitral Valve E-F Slope (E-F Slope) - Aortic Valve Peak Velocity (AV Velocity (MR Trace)

LOGIQ P5 Page 9 of 14
- Mitral Valve Velocity Time Integral - Pulmonic End-Diastolic Velocity (PV • System
(MR Trace) Trace) - Pulmonary Artery Peak Velocity (PV
- Mitral Valve Mean Pressure Gradient - Pulmonary Artery Diastolic Pressure Vmax)
(MR Trace) (PV Trace) - Pulmonary Vein Velocity Peak A
- Mitral Regurgitant Peak Pressure - Pulmonic Insufficiency Mean Pressure (reverse) (P Vein A)
Gradient (MR Vmax) Gradient (PR Trace) - Pulmonary Vein Peak Velocity (P Vein
- Mitral Valve Peak Pressure Gradient - Pulmonic Valve Mean Pressure D, P Vein S)
(MR Vmax) Gradient (PV Trace) - Systemic Vein Peak Velocity (PDA
- Mitral Regurgitant Peak Velocity (MR - Pulmonic Insufficiency Mean Velocity Diastolic, PDA Systolic)
Vmax) (PR Trace) - Ventricular Septal Defect Peak
- Mitral Valve Peak Velocity (MR - Pulmonic Insufficiency Mean Square Velocity (VSD Vmax)
Vmax) Root Velocity(PR Trace) - Atrial Septal Defect (ASD Diastolic,
- Mitral Valve Velocity Peak A (MV A - Pulmonic Insufficiency Velocity Time ASD Systolic)
Velocity) Integral (PR Trace) - Pulmonary Artery Velocity Time
- Mitral Valve Velocity Peak E (MV E - Pulmonic Valve Mean Velocity (PV Integral (PV Trace)
Velocity) Trace) - Systemic Vein Velocity Time Integral
- Mitral Valve Area according to PHT - Pulmonic Valve Mean Square Root (PDA Trace)
(MV PHT) Velocity (PV Trace) - Pulmonary Vein A-Wave Duration (P
- Mitral Valve Flow Deceleration (MV - Pulmonic Valve Velocity Time Integral Vein A Dur)
Trace) (PV Trace) - IsoVolumetric Relaxation Time (IVRT)
- Mitral Valve Pressure Half Time (PV - Pulmonic Insufficiency Pressure Half - IsoVolumetric Contraction Time
PHT) Time (PR PHT) (IVCT)
- Mitral Valve Flow Acceleration (MV - Pulmonic Valve Flow Acceleration (PV - Pulmonary Vein S/D Ratio (P Vein D,
Trace) Acc Time) P Vein S)
- Mitral Valve E-Peak to A-Peak Ratio - Pulmonic Valve Acceleration Time - Ventricular Septal Defect Peak
(A-C and D-E) (MV E/ARatio) (PV Acc Time) Pressure Gradient (VSD Vmax)
- Mitral Valve Acceleration Time (MV - Pulmonic Valve Ejection Time (PVET) - Pulmonic-to-Systemic Flow Ratio
Acc Time) - Pulmonic Valve Pre-Ejection Period (Qp/Qs)
- Mitral Valve Deceleration Time (MV (PVPEP) • Tricuspid Valve
Dec Time) - QRS complex to end of envelope (Q- - Tricuspid Regurgitant Peak Pressure
- Mitral Valve Ejection Time ((MV to-PV close) Gradient (TR Vmax)
Trace) - Pulmonic Valve Acceleration to - Tricuspid Valve Peak Pressure
- Mitral Valve A-Wave Duration (MV A Ejection TIme Ratio (PV Acc Time, Gradient (TV Vmax)
Dur) PVET) - Tricuspid Regurgitant Peak Velocity
- Mitral Valve Time to Peak (MV Trace) - Pulmonic Valve Pre-Ejection to (TR Vmax)
- Mitral Valve Acceleration Ejection Time Ratio (PVPEP, PVET) - Tricuspid Valve Peak Velocity (TV
Time/Deceleration Time Ratio • Right Ventricle Vmax)
(MVAcc/Dec Time) - Right Ventricle Outflow Tract Peak - Tricuspid Valve Velocity Peak A (TV
- Stroke Volume Index by Mitral Flow Pressure Gradient (RVOT Vmax) A Velocity)
(MVA Planimetry, MVTrace) - Right Ventricle Systolic Pressure - Tricuspid Valve Velocity Peak E (TV E
- Mitral Valve Area from Continuity (RVOT Vmax) Velocity)
Equation (MVAPlanimetry, LVOT - Right Ventricle Outflow Tract Peak - Tricuspid Regurgitant Mean Pressure
Vmax, MV Vmax) Velocity (RVOT Vmax) Gradient (TR Trace)
• Pulmonic Valve - Right Ventricle Diastolic Pressure - Tricuspid Valve Mean Pressure
- Pulmonic Insufficiency Peak Pressure (RVOT Trace) Gradient (TV Trace)
Gradient (PR Vmax) - Right Ventricle Outflow Tract Velocity - Tricuspid Regurgitant Mean Velocity
- Pulmonic Insufficiency End-Diastolic Time Integral (RVOTTrace) (TR Trace)
Pressure Gradient (PRTrace) - Right Ventricle Ejection Time (RV - Tricuspid Regurgitant Mean Square
- Pulmonic Valve Peak Pressure Trace) Root Velocity (TR Trace)
Gradient (PV Vmax) - Stroke Volume by Pulmonic Flow - Tricuspid Regurgitant Velocity Time
- Pulmonic End-Diastolic Pressure (RVOT Planimetry, RVOTTrace)
Gradient (PR Trace) - Right Ventricle Stroke Volume Index
- Pulmonic Insufficiency Peak Velocity by Pulmonic Flow (RVOT Planimetry,
(PR Vmax) RVOT Trace)
- Pulmonic Insufficiency End-Diastolic
Velocity (Prend Vmax)
- Pulmonic Valve Peak Velocity
(PV Vmax)

LOGIQ P5 Page 10 of 14
Integral (TR Trace) Pl ani met ry, AV Trace) • Pulmonic Valve
- Tricuspid Valve Mean Velocity (TV - Cardiac Output by Aortic Flow (AVA - Stroke Volume by Pulmonic Flow (PV
Trace) Planimetry, AV Trace, HR) Planimetry, PV Trace)
- Tricuspid Valve Mean Square Root - Aortic Valve Area by Continuity - Cardiac Output by Pulmonic Flow (PV
Velocity (TV Trace) Equation VTI (Ao Root Diam, LVOT Planimetry, PV Trace, HR)
- Tricuspid Valve Velocity Time Integral Vmax, AV Trace) • Tricuspid Valve
(TV Trace) • Left Ventricle - Cardiac Output by Tricuspid Flow (TV
- Tricuspid Valve Time to Peak (TV - Cardiac Output, Teichholz/Cubic Planimetry, TV Trace, HR)
Acc/Dec Time) (LVIDd, LVI Ds, HR)
- Tricuspid Valve Ejection Time (TV - Cardiac Output Two Chamber, Single Cardiac Worksheet
Acc/Dec Time) Plane, Area-Length/ Method of
- Tricuspid Valve A-Wave Duration (TV Disk(Simpson) (LVAd, LVAs, HR) Vascular
A Dur) - Cardiac Output Four Chamber, Single Measurements/Calculations
- QRS complex to end of envelope (Q- Plane, Area-Length/ Method of Exam Categories
to-TV close) Disk(Simpson) (LVAd, LVAs, HR) • Generic
- Tricuspid Valve Pressure Half Time - Ejection Fraction Two Chamber, Single • Carotid Artery
(TV PHT) Plane, Area-Length/ Method of • Lower Extremity Artery
- Stroke Volume by Tricuspid Flow (TV Disk(Simpson) (LVAd, LVAs) • Lower Extremity Vein
Planimetry, TV Trace) - Ejection Fraction Four Chamber, Single • Abdomen
- Tricuspid Valve E-Peak to A-Peak Plane, Area-Length/ Method of • Renal Artery
Ratio (TV E/A Velocity) Disk(Simpson) (LVAd, LVAs) • TCD (Trans Cranial Doppler)
- Left Ventricle Stroke Volume, Single • Upper Extremity Artery
Color Flow Mode Measurements Plane, Two Chamber/Four Chamber, • Upper Extremity Vein
• Aortic Valve Area-Length (LVAd, LVAs)
- Proximal Isovelocity Surface Area: - Left Ventricle Stroke Volume, Single B-Mode Measurements
Regurgitant Orifice Area (AR Radius) Plane, Two Chamber/Four Chamber, • % Stenosis
- Proximal Isovelocity Surface Area: Method of Disk(Simpson) (LVIDd, - Diameter
Radius of Aliased Point (AR Radius) LVIDs, LVAd, LVAs) - Area
- Proximal Isovelocity Surface Area: - Left Ventricle Volume, Two • Volume
Regurgitant Flow (AR Trace) Chamber/Four Chamber, Area-Length - One distance
- Proximal Isovelocity Surface Area: (LVAd, LVAs) - Two distances
Regurgitant Volume Flow (AR Trace) - Ejection Fraction, Bi-Plane, Method of - Three distances
- Proximal Isovelocity Surface Area: Disk (LVAd, LVAs, 2CH, 4CH) - One ellipse
Aliased Velocity (AR Vmax) - Left Ventricle Stroke Volume, Bi-Plane, - One distance and one ellipse
• Mitral Valve Method of Disk (LVAd, LVAs, 2CH, • A/B Ratio
- Proximal Isovelocity Surface Area: 4CH) - Diameter
Regurgitant Orifice Area (MR Radius) - Left Ventricle Volume, Bi-Plane, - Area
- Proximal Isovelocity Surface Area: Method of Disk (LVAd, LVAs, 2CH,
Radius of Aliased Point (MR Radius) 4CH) M-Mode Measurements
- Proximal Isovelocity Surface Area: - Left Ventricle Stroke Index, Single • % Stenosis
Regurgitant Flow (MR Trace) Plane, Two Chamber/Four Chamber, - Diameter
- Proximal Isovelocity Surface Area: Area-Length (LVSd, LVSs, and BSA) • A/B Ratio
Regurgitant Volume Flow (MR Trace) - Left Ventricle Volume, Single Plane, - Diameter
- Proximal Isovelocity Surface Area: Two Chamber/Four Chamber, Method - Time
Aliased Velocity (MR Vmax) of Disk (LVAd, LVAs) - Velocity
- Left Ventricle Volume, Apical View,
Combination Mode Measurements Long Axis, Method of Disk (LVAd, LVAs) Doppler Mode Measurements
• Aortic Valve - Stroke Volume by Aortic Flow (AVA Auto Vascular Calculation
- Aortic Valve Area (Ao Root Diam, Planimetry, AV Trace) • Acceleration
LVOT Vmax, AV Vmax) • Mitral Valve • Acceleration Time (AT)
- Aortic Valve Area by Continuity - Stroke Volume by Mitral Flow (MVA • End Diastole (ED), Mid Diastole (MD)
Equation by Peak Velocity (Ao Root Planimetry, MV Trace) or Peak Systole (PS)
Diam, LVOT Vmax, AV Vmax) - Cardiac Output by Mitral Flow (MVA
- Stroke Volume by Aortic Flow (AVA Planimetry, MV Trace, HR)

LOGIQ P5 Page 11 of 14
• ED/PS or PS/ED Ratio • 4C Wide band Convex Probe • ERB Biplane Probe
• Heart Rate - Applications: Abdomen, OB Gyn, - Applications: Urology
• Pulsatility Index (PI) Urology, and Vascular - Probe Band Width:
• Resistive Index (RI) - Maximum Band Width (-20dB): 1.4 – ERB Linear: 4.7 – 9.5 MHz
• TAMAX 4.8 MHz ERB Convex: 4.5 – 8.8 MHz
• Edit Trace - Number of Elements: 128 - Number of Element:
- Convex Radius: 60 mm ERB Linear: 128 Elements
Vascular Worksheet - FOV: 55° ERB Convex: 128 Elements
• Vessel Worksheet - Foot Print: 60mm x 18 mm - Probe Radius:
• Vessel Summary - Fundamental Frequency: 2,3,4,5 MHz ERB Convex Radius: 8 mmR
• Examiner’s Comments - Harmonic Frequency: 4,5,5.2,5.5 MHz ERB Linear Radius: 0 mmR
• Generic Worksheet - Doppler Frequency: 2.5, 3.3 MHz - FOV (Max):
• Intravessel Ratio - Biopsy Guide Available: Single Angle, ERB Convex FOV (Max): 122°
Reusable ERB Linear FOV (Max): 51.2mm
Pediatrics - Physical Foot Print:
Measurements/Calculations • E8C Wide Band Microconvex Probe ERB Convex: 17 x 5.5 mm
• Hip Dysplasia - Applications: OB, Gyn, Urology, ERB Linear: 51 x 5 mm
• Alpha HIP Endocavity - B-mode Imaging Frequency: 6.0, 8.0,
• d:D Ratio - Probe Band Width: 4.0 – 11.0 MHz 10.0 MHz
- Number of Element: 128 - Harmonic Frequency: 8.0, 10.0 MHz
- Convex Radius: 11 mmR - Doppler Frequency: 5.0, 6.7 MHz
Probes - FOV (Max): 133° - Biopsy Guide Available: Brachy Grid,
- Physical Foot Print: 26 x 5 mm Bridge Biopsy Guide
• 3.5CS Thin Wide Band Convex Probe - B-mode Imaging Frequency: 6.0, 8.0,
- Applications: Abdomen, OB Gyn, 10.0 MHz • 3S Wide Band Phased Array Sector
Urology, Vascular - Doppler Frequency: 4.0, 5.0 MHz Probe
- Probe Band Width: 2.0 – 5.0 MHz - Biopsy Guide Available: Single Angle, - Applications: Cardiac, Transcranial,
- Number of Element: 128 Disposable, Reusable Abdomen
- Convex Radius: 38 mmR - Probe Band Width: 1.5 – 3.5 MHz
- FOV (Max): 68° • 8C Wide Band Microconvex Probe - Number of Element: 64
- Physical Foot Print: 48 x 11 mm - Applications: Pediatric, Neonatal - FOV (Max): 90°
- B-mode Imaging Frequency: 2.0, 3.0, - Probe Band Width: 4.0 – 11.0 MHz - Physical Foot Print: 18.5 x 18.5 mm
4.0, 5.0 MHz - Number of Element: 128 - B-mode Imaging Frequency: 2.0, 2.5,
- Harmonic Frequency: 4, 5, 5.2, 5.5 - Convex Radius: 11 mmR 3.0 MHz
MHz - FOV (Max): 133° - Harmonic Frequency: 3.2, 3.6 MHz
- Doppler Frequency: 2.5, 3.3 MHz - Physical Foot Print: 26 x 5 mm - Doppler Frequency: 1.7, 2.0 MHz
- Biopsy Guide Available: Single Angle, - B-mode Imaging Frequency: 6.0, 8.0, - St-CWD Frequency: 2.0 MHz
Reusable 10.0 MHz - Biopsy Guide Available: Multi Angle,
- Doppler Frequency: 4.0, 5.0 MHz Reusable
• 3.5C Thin Wide Band Convex Probe - Biopsy Guide Available: None
- Applications: Abdomen, OB Gyn, • 5S Wide Band Phased Array Sector
Urology, Vascular • BE9C Micro convex Bi-plan Probe Probe
- Probe Band Width: 2.0 – 5.0 MHz - Applications: Urology - Applications: Cardiac, Transcranial,
- Number of Element: 128 - Probe Band Width: 4.0 – 11.0 MHz Abdomen
- Convex Radius: 38 mmR - Number of Element: 96 - Probe Band Width: 2.2 – 5.3 MHz
- FOV (Max): 68° - Convex Radius: 9 mmR - Number of Element: 96
- Physical Foot Print: 48 x 11 mm - FOV (Max): 127° - FOV (Max): 90°
- B-mode Imaging Frequency: 2.0, 3.0, - Physical Foot Print: 20 x 5 mm - Physical Foot Print: 14.4 x 11 mm
4.0, 5.0 MHz - B-mode Imaging Frequency: 6.0, 8.0, - B-mode Imaging Frequency: 3.0, 4.0,
- Harmonic Frequency: 4, 5, 5.2, 5.5 10.0 MHz 5.0 MHz
MHz - Harmonic Frequency: 8, 10MHz - Harmonic Frequency: 4.0, 5.0 MHz
- Doppler Frequency: 2.5, 3.3 MHz - Doppler Frequency: 4.0, 5.0 MHz - Doppler Frequency: 2.5, 3.3 MHz
- Biopsy Guide Available: Single Angle, - Biopsy Guide Available: Single Angle,
Reusable Reusable

LOGIQ P5 Page 12 of 14
- St-CWD Frequency: 2.5 MHz - Physical Foot Print: 40 x 9 mm - Band Width (-20dB): 2 – 5 MHz
- Biopsy Guide Available: Multi Angle, - B-mode Imaging Frequency: 6.0, 8.0, - Number of Elements: 192
Reusable 10.0 MHz - Convex Radius: 40.5 mm
- Doppler Frequency: 5, 6.7 MHz - Volume Sweep Radius: 20,15mm
• 7S Wide Band Phased Array Sector - Steered Angle: +/- 10°, 20° -FOV: 80° (B), 85° x 80° (Volume scan)
Probe - Harmonic Frequency: 8, 10 MHz - Foot Print: 53,2 x 40,6
- Applications: Neonatal, Abdomen, - Biopsy Guide Available: Multi Angle, - Fundamental Freq: 3, 4, 5 MHz
Pediatrics Reusable - Harmonic Frequencies: 4, 4.5, 4.8, 5.0
- Probe Band Width: 3.0 – 8.0 MHz MHz
- Number of Element: 64 • 9L Wide Band Linear Probe - Color Frequencies: 2.5,3.3 MHz
- FOV (Max): 90° - Applications: Vascular, Small Parts, - Doppler Frequencies: 2.5, 3.3 MHz
- Physical Foot Print: 9.3 x 7.0 mm Neonatal, and Pediatrics - Biopsy Guide Available: Single Angle,
- B-mode Imaging Frequency: 5.0, 6.0, - Probe Band Width (-20dB): 2.7– 7.8 Reusable
7.0 MHz MHz
- Doppler Frequency: 3.3, 4.0 MHz - Number of Element: 192 • P2D Non-imaging Single CW Doppler
- St-CWD Frequency: 4.0 MHz - FOV (Max): 39 x 160 mm Pencil Probe
- Biopsy Guide Available: None - Physical Foot Print: 44 x 6 mm - Applications: Cardiac
- B-mode Imaging Frequency: 6.0, 7.0, - Frequency: 2.0 MHz
• 10L Wide Band Linear Probe 9.0 MHz
- Applications: Vascular, Small Parts, - Doppler Frequency: 4.0, 5 MHz • P6D Non-imaging Single CW Doppler
Neonatal, Pediatrics - Steered Angle: +/- 10°, 20° Pencil Probe
- Probe Band Width: 3.5 – 9.5 MHz - Harmonic Frequency: 8, 10 MHz - Applications: Cardiac, Vascular,
- Number of Element: 192 - Biopsy Guide Available: Multi Angle, Pediatric
- FOV (Max): 39 mm Reusable - Frequency: 5.0 MHz
- Physical Foot Print: 39 x 5 mm
- B-mode Imaging Frequency: 6.0, 8.0, • T739 Intraoperative Wide Band Linear Inputs and Outputs
10.0 MHz Probe
- Doppler Frequency: 5.0, 6.7 MHz - Applications: Intraoperative • Video In
- Steered Angle: +/- 10°, 20° - Probe Band Width: 3.5 – 9.5 MHz - S-Video
- Biopsy Guide Available: Multi Angle, - Number of Element: 192 • Video Out
Reusable - FOV (Max): 39 mm - S-Video
- Physical Foot Print: 39 x 5 mm • Audio Stereo In
• 12L Wide Band Linear Probe - B-mode Imaging Frequency: 6.0, 8.0, • Connectors
- Applications: Small Parts, Vascular, 10.0 MHz - Footswitch
Neonatal, Pediatrics - Harmonic Frequency: 8.0, 10.0 MHz - USB (6)
- Probe Band Width: 5.0 – 12.0 MHz - Doppler Frequency: 5.0, 6.7 MHz - Ethernet
- Number of Element: 192 - Steered Angle: +/- 10°, 20° - Power for Peripherals
- FOV (Max): 39 mm - Biopsy Guide Available: Multi Angle,
- Physical Foot Print: 45 x 10 mm Reusable Safety Conformance
- B-mode Imaging Frequency: 7.0, 10.0,
12.0 MHz • I739 Intraoperative Wide Band Linear The LOGIQ P5 is:
- Harmonic Frequency: 10.0, 12.0 MHz Probe • Listed to UL 2601-1 by a Nationally
- Doppler Frequency: 5.0, 6.7 MHz - Applications: Intraoperative Recognized Test Lab
- Steered Angle: +/- 10°, 20° - Probe Band Width: 3.5 – 9.5 MHz • Certified to CSA 22.2, 60601.1 by an
- Biopsy Guide Available: Single Angle, - Number of Element: 192 SCC accredited Test Lab
Reusable - FOV (Max): 39 mm • CE Marked to Council Directive
- Physical Foot Print: 39 x 5 mm 93/42/EEC on Medical Devices
• 8L Wide Band Linear Probe - B-mode Imaging Frequency: 6.0, 8.0, • Conforms to the following standards for
- Applications: Vascular, Small Parts, 10.0 MHz safety:
Neonatal, and Pediatrics - Harmonic Frequency: 8.0, 10.0 MHz - EN 60601-1 Electrical medical equipment
- Probe Band Width (-20dB): 3.5– 10.5 - Doppler Frequency: 5.0, 6.7 MHz - EN 60601-1-1 Electrical medical
MHz - Steered Angle: +/- 10°, 20° equipment
- Number of Element: 128 - Biopsy Guide Available: None - EN 60601-1-2 Electromagnetic
- FOV (Max): 39 x 160 mm compatibility
• 4D3C-L Convex Volume Probe
- Applications: Abdomen, OB

LOGIQ P5 Page 13 of 14
- EN 60601-1-4 Programmable medical
systems
- EN 60601-2-37 Particular requirements
for the safety of ultrasonic medical
diagnostic and monitoring equipment
- IEC 61157 Declaration of acoustic
output
- ISO 10993 Biological evaluation of
medical devices
- NEMA UD3 Acoustic output display
(MI, TIS, TIB, TIC)

Not all features or specifications


described in this document may be
available in all probes and/or modes.

General Electric Company reserves the


right to make changes in specifications
and features shown herein, or
discontinue the product at any time
without notice or obligation. Contact GE
Representative for the most current
information.

LOGIQ P5 Page 14 of 14