Professional Documents
Culture Documents
63000
DD
OWNER
STATE OF KUWAIT - MINISTRY OF PUBLIC WORKS
8625
KEY PLAN CA
MEC
H
C0
RT
NO
CUP
DD"
30 10
40 HSP 20
CRP
D
A
50
03
ANX
15150
B 60
SUPERVISION
PACE | ARCHITECTURE ENGINEERING + PLANNING
715
CA
1930
1930
1930
1930
1930
1930
1510 3600 3600 3720 3480 3600 3600 3600 3600 3600 3600 3600 3600 3600 3600 3600 3600 3600 750
T.O FOOTING
Ø25 Ø32 FFL +17.100 Ø25 Ø25 Ø25 Ø25
(C.L.P + 25.550)
(C.L.P + 25.550)
(C.L.P + 25.550)
Ø25
GUTTER GUTTER GUTTER FIRE SECTOR
GUTTER Z-01 GUTTER
(C.L.P + 25.550)
(C.L.P + 25.550)
(C.L.P + 25.550)
(C.L.P + 25.550)
(C.L.P + 25.550)
(C.L.P + 25.550)
(C.L.P + 25.550)
(C.L.P + 25.550)
(C.L.P + 25.550)
(C.L.P + 25.550)
(C.L.P + 25.550)
(C.L.P + 25.550)
1169 SM
Ø40
3300
3300
3300
3300
3300
3300
Ø25
Ø25
Ø25
Ø25
Ø25
Ø25
Ø25
Ø25
Ø25
Ø25
Ø25
Ø25
F.F.L
+22.300 m
T.O.C
Ø25 Ø25 Ø25 Ø25 Ø25 Ø25
F.F.L
AS BUILT
R.C
10500
(C.L.P + 25.550)
Ø25
T.O.C
ZONE -01
Ø25
Ø25
Ø25
Ø25
Ø25
Ø25
Ø25
Ø25
Ø32
Ø25
+22.200 m
Ø40
3300
3300
3300
3300
3300
3300
Ø40
Ø32
Ø25
IMPRESA PIZZAROTTI & C. S.P.A
1510 3600 3600 3600 3600 3600 3600 3000 2900 3400 3000 3000 3800 3000 3700 3000 3600 3600 3600 750
DV
(C.L.P + 25.250)
Ø40 Ø50
(C.L.P + 25.250)
Ø65
(C.L.P + 25.250)
Ø65 Ø65 Ø25 Ø25 Ø25 Ø25 Ø25 Ø25
ZONE -01
(C.L.P + 25.550)
Ø32 Ø25
(C.L.P + 25.550)
Ø25
(C.L.P + 25.550)
(C.L.P + 25.550)
1850
(C.L.P + 25.550)
(C.L.P + 25.550)
(C.L.P + 25.550)
(C.L.P + 25.550)
Ø50
(C.L.P + 25.550)
(C.L.P + 25.550)
Ø32
Ø25
Ø40
Ø32
3000
Ø32
Ø25
Ø40
(C.L.P + 25.550)
Ø32
3300
3300
3300
3300
Ø40
Ø25 CONN. TO FHC
Ø32
Ø50
Ø65
CA'
180
AL-AHLIA INTEGRATED
L.V GENERAL TRADING & CONTRACTING CO. W.L.L
SPS A
I N T EG R AL-AHLIA MEP DIVISION
PV Room Ø100 FIRE PIPE F/B-T/H/L
AT
Thermal plant
I
AH L
ED
C02-MEP-08[M_0900] C02-MEP-01[M_0900] INTEGRATED P.O Box: 22240 Safat, P.C 13083 Kuwait
(C.L.P + 25.400)
Ø100 FP @ H/L
13.55 m²
ES
197
7
Ø40
1024.45 m²
T
Ø25
Ø25
Ø25
Ø25
Ø25
EMAIL: alahlia.ing@falghanim.com
Ø50
Ø40
Ø50
Ø50
170
Ø40
Ø40
Ø40
Ø40
2500
FF
3000
Ø25
3300
3000
3400
Stairs S01
C02-GEN-01[A_0002] DV
Ø25
27.41 m² Ø100 Ø100 Ø100 Ø100 Ø100 Ø100 Ø100 Ø100 Ø100 Ø80 Ø80 Ø80 Ø65 Ø65 Ø50
1400 6Kg DRY
01 (C.L.P + 25.250) (C.L.P + 25.250) (C.L.P + 25.250) (C.L.P + 25.250) (C.L.P + 25.250) (C.L.P + 25.250)
Ø32
POWDER
500
830
Ø32
Ø32
Ø50
Ø25
Ø25
Ø25
Ø25
Ø25
Ø25
Ø25
Ø25
Ø25
500
ICT RISER
76275
200
Ø100
(C.L.P + 25.550)
(C.L.P + 25.550)
(C.L.P + 25.550)
3600 3600 3600 3600 3600 3600 3600 3000 650
Ø25
(C.L.P + 25.550)
(C.L.P + 25.550)
Ø25 Ø25 Ø25 Ø25 1480 3000 3600 3600
1780
LEVEL 2
10500
R.C
Thermal plant
Ø32
(C.L.P + 25.550)
Ø25
Ø25
Ø25
3000
3000
FFL +16.900 Control Room
Ø40
C02-MEP-09[M_0900]
Ø25 (C.L.P + 25.250) Ø40 Ø100 8.00 m²
200
3600
Ø25
Ø25
C02-MEP-04[M_0900]
C02-GEN-02[A_0000]
(C.L.P + 25.400)
R.C
R.C
Corridor
(C.L.P + 25.550)
Ø25
2500
75.21 m²
Ø40
Ø150mm WALL SLEEVE FOR F.P LV-N Room
2800
C02-MEP-02[M_0900]
Ø25
Ø25
Ø25
290
6Kg DRY
76.22 m²
I.L. 25.20 LEVEL 2
T.O.C C02-MEP-07[E_2000]
13.40 m²
Ø65mm FP F/H/L TO L.V FP FIRE MAIN PIPE
1920
POWDER Ø50 DRAIN PIPE NEAREST
FFL +16.900 +22.200 m
200 Ø32 HRP F/H/L-T/L/L & Ø25 Ø100 FIRE PIPE F/B-T/A HOSE REEL PIPE F/A FROM ABOVE
CONN. TO FHC FOR DRAIN POINT SP SPRINKLER MAIN PIPE
500
1600
880
170
Ø32
CB (C.L.P + 25.250) 02 DRAIN PIPE T/A TO ABOVE
L.V HYDRANT PIPE
200
1860
MEP Shaft
EP-CT-06 EP-CT-05 EP-CT-04 EP-CT-03 EP-CT-02 EP-CT-01 L.V
3500
Ø25
C02-MEP-05[M_0900]
12.75 m² LEVEL 2 F/H/L FROM HIGH LEVEL
DUTY DUTY DUTY DUTY DUTY DUTY FAN DECK LADDER & FIRE HOSE CABINET WITH 1no. Ø25X30M HOSE
(C.L.P + 25.250)
REEL, 6 kg MULTIPURPOSE DRY POWER FIRE F/L/L
FHC EXTINGUISHER, 9Liter WATER FIRE EXTINGUISHER FROM LOW LEVEL
1310
10500
TO LOW LEVEL
R.C
ICT RISER
2850x3300
UPRIGHT SPRINKLER
B.O.OP+1250@ LVL +16.900
COOLING TOWER 432 432 432 C.L.P CENTER LEVEL PIPE
5 1 5 1 5 1 PENDENT SPRINKLER
200
FOR
FORFUTURE
FUTURE
Ø DIAMETER
1 234
5 1 234
5 1 234
5 PENDENT & UPRIGHT SPRINKLER
QUICK RESPONSE SPRINKLER F.F.L FINISH FLOOR LEVEL
PRV PRESSURE REDUCING VALVE.
FINISH FLOOR
LEVEL CHANGING
FHC
DV DRAIN VALVE FF - DISCIPLINE
430
X - RISER NUMBER
1251
GV GATE VALVE
CB' CHV CHECK VALVE
BFV NRV NON-RETURN VALVE
CONC. FOUNDATION Ø32 HRP F/H/L-T/L/L & Ø25
CONN. TO FHC
R.C
R.C
CC
GENERAL NOTES:
Ø150mm WALL SLEEVE FOR F.P
I.L. 25.20 1. ALL DIMENSIONS ARE IN MILLIMETERS & LEVELS IN METERS.
FF Ø100 FIRE PIPE F/B-T/A
5
432
1 5
432
1 03 5
432
1
160
190
1 5 1 5 1 5
234 234 234
Stairs S03
180
C02-GEN-03[A_0002]
27.89 m² FHC PLUMBING & FIRE FIGHTING 22-05-2022
10500
T.O.C
R.C
R.C
+21.700 m Ø32 HRP F/H/L-T/L/L & Ø25 T.O.C
CONN. TO FHC +21.700 m
Ø65 HRP @ H/L
(C.L.P + 25.250)
715 200
CC' T.O.UP STAND +17.990 CUP - LEVEL 2 - ZONE C0 - FIRE PROTECTION PLAN
R.C R.C
715 600 5800 600 600 5800 1200 5800 600 600 6800 6200 6800 600 600 5800 1200 5800 600 600 5800 600 715
AHL_SH_ME_FF_CUP_L02_C0_PL_0001_02 TR-21799 21 (15)
290