You are on page 1of 15

SENSETE°CH® CWC HEAT-EDGE® RAINBOW DOTECH SHIMADEN PR ELECTRONICS KIMO OHKURA SEKONIC HUBA KAISE CORDEX FRIED ELECTRIC

SENSING & CONTROL


DOTECH
Product Index

SENSETE°CH®
SECTION V. DOTECH SENSING & CONTROL CATALOGUE

CWC
A. FX Series

HEAT-EDGE®
Digital Temperature Controller ................................................................................................................................................................................................................................................................................ V-A1
Digital Humidity Controller ............................................................................................................................................................................................................................................................................................ V-A2
Refrigeration Controller .................................................................................................................................................................................................................................................................................................... V-A3
Multi-function Digital Controller .............................................................................................................................................................................................................................................................................. V-A5

B. DX Series

RAINBOW
HVAC Controller ...................................................................................................................................................................................................................................................................................................................... V-B6
Screw Compressor Controller ................................................................................................................................................................................................................................................................................... V-B7
Multi Compressor Controller ....................................................................................................................................................................................................................................................................................... V-B9
Geothermy Heat Pump Controller ........................................................................................................................................................................................................................................................................ V-B10
Air-Source Heat Pump Controller .......................................................................................................................................................................................................................................................................... V-B11

DOTECH
HTX Series
Economical Module Type Temperature And Humidity Sensor ............................................................................................................................................................................................ V-C12
OEM Temperature and Humidity Sensor ...................................................................................................................................................................................................................................................... V-C12
Ultra-recise Indoor Type Temperature And Humidity Transmitter ....................................................................................................................................................................................... V-C13
Analog Voltage Relative Humidity Module .............................................................................................................................................................................................................................................. V-C13

SHIMADEN
PR ELECTRONICS
KIMO
OHKURA
SEKONIC
HUBA
KAISE
CORDEX
FRIED ELECTRIC

Sensing Technology Corporation 457-B Boni Avenue New Zaniga Mandaluyong City www.heatsenze.com sales@heatsenze.com Tel No. 532-0088 Fax No. 531-7387
SENSETE°CH®
FX Series

CWC
DIGITAL TEMPERATURE CONTROLLER
FX3S Digital Temperature Controller
FX3D Digital Temperature Controller NTC Heating Cooling Defrost 4~20mA RS485 Retrans

HEAT-EDGE®
NTC Heating Cooling Thermostat Defrost

RAINBOW
OUT1 Heating/cooling
: output 4~20mA 4~20mA
OUT2 Heating/cooling
: ouput signal input wiring method
for loop power sensor
out1 : heating/cooling output - Timer output

DOTECH
- Sensor error detection
alarm output
- Heater defrost output
- Hot gas defrost output

Heating/cooling output, precise temperature control, sensor Heating/cooling output, independent timer output, high/low alarm
Main- correction, sensor detection, data backup, min. on/off maintaining Main- output, defrost output, precise temperature control, sensor correction,
Function time setup, auto-output operation cycle settable in case of sensor Function sensor error detection, data backup, min. on/off maintaining time setup,

SHIMADEN
error RS485 communication (MODBUS), auto-output operation cycle
settable in case of error, transmission output
Power Supply AC100~240V, 50/60Hz, Max. 4VA, screw bolt terminals
Power Supply AC100~240V, 50/60Hz, Max. 4VA, screw bolt terminals
Input/output Relay output : 1point (16A), Temp. sensor input : 1 point (NTC)
Relay output : 1point (16A), Temp. sensor input : 1 point (NTC)

PR ELECTRONICS
DPR-TH1 : NTC 5k, ±0.3°C at 25°C(-55~105°C) Input/output 4~20mA Input : 1 point (including power supply)
Sensor Spec DPR-TH2 : NTC 10k, ±0.3°C at 25°C (-50~150°C)
DPR-TH1 : NTC 5k, ±0.3°C at 25°C(-55~105°C)
Models FX3S-00 : Basic model (with DPR-TH1-ET temperature sensor) Sensor Spec DPR-TH2 : NTC 10k, ±0.3°C at 25°C (-50~150°C)

FX3S - 00 : Basic model (with DPR-TH1-ET temperature sensor)


FX3D-R4 : Add on Rs485 communication (MODBUS)
FX3D - A4 : Add on 4~20mA transmission output

KIMO
Models FX3D - R2 : Add on RS232 communication
FX3D - A1R4 : Add on 4~20mA transmission output,
RS485 communication (MODBUS)

FX3FS Digital Temperature Controller NTC Heating Cooling Retrans


FX3T Digital Temperature Controller CA(K) Heating Cooling RS485 Retrans

OHKURA
FX3FS-00
16A, 250Vac
n1 n2 n3
POWER

SEKONIC
L1 L2 COM B1 B2
c

1 2 4 5 6 8 9 10
AC100-240V ~ OUT NTC
50/60Hz
T1 T2

n1 : HEAT/COOL #1 ON/OFF output,


OUT1 : hea ng/cooling on/off output alarm output
Save : T1 - temperature sensor#1
HUBA

T2 - temperature sensor#2 n2 : HEAT/COOL #2 ON/OFF output,


alarm output

n3 : HEAT/COOL #3 ON/OFF output,


alarm output
KAISE

Main- Heating/cooling output, precise temperature control, sensor correction, Main- Heating/cooling output, high/low alarm output, precise temperature
sensor error detection, data back up, min. on/off maintaining time control, sensor correction, sensor error detection, data backup
Function setup, defrost output, virtual input function, function to prevent Function min. on/off maintaining time setup, transmission output, RS485
incorrect operation caused by sensor error communication (MODBUS)

Power Supply AC100~240V, 50/60Hz, Max. 4VA, screw bolt terminals Power Supply AC100~240V, 50/60Hz, Max. 4VA, screw bolt terminals
CORDEX

Input/output Relay output : 1point (16A), Temp. sensor input : 1 point (NTC) Input/output Relay output : 3point (10A), Temp. sensor input : 1 point (thermo-couple)
DPR-TH1 : NTC 5k, ±0.3°C at 25°C(-55~105°C) Sensor Spec Thermo-couple K type : Measuring range : 0~1000°C
Sensor Spec DPR-TH2 : NTC 10k, ±0.3°C at 25°C (-50~150°C)
Models FX3S - 00 : Basic model (with 2 pcs ofDPR-TH1-ET temperature sensor)
Models FX3S - 00 : Basic model (with 2 pcs ofDPR-TH1-ET temperature sensor)
FRIED ELECTRIC

Sensing Technology Corporation 457-B Boni Avenue New Zaniga Mandaluyong City www.heatsenze.com sales@heatsenze.com Tel No. 532-0088 Fax No. 531-7387

V-A1
SENSETE°CH®

FX Series
CWC

DIGITAL TEMPERATURE CONTROLLER


FX3QR / FX3SR Digital Temperature Controller PT100 Heating Cooling RS485 Retrans
HEAT-EDGE®

Heating/cooling output, precise temperature control, data backup,


Main- min. on/off maintaining time setup, relay output manually controllable,
Function transmission output, sensor correction, sensor error detection, RS485
RAINBOW

communication (MODBUS)

Power Supply AC100~240V, 50/60Hz, Max. 4VA, screw bolt terminals


FX3QR : Relay output : 4 point, Temp. sensor input : 1 point (Pt100)
Input/output FX3SR : Relay output : 1 point (16A), temp. sensor input : 1 point (Pt100)
DOTECH

Sensor Spec Pt100 3(2) Wire, Measuring range : -200~800°C, ±0.3°C


FX3QR / FX3SR-00 : Basic model
FX3QR / FX3SR-R4 : Add on RS485 communication (MODBUS)
Models FX3QR /FX3SR-A1 : Add on 4~20mA transmission output
FX3QR /FX3SR-A1 : Add on RS232 communication
SHIMADEN

N1,2 : 10A, 250V


N3,4 : 5A, 250V
PR ELECTRONICS

n1 n2 n3 n4

n1 : HEAT/COOL #1 output, event output n1 : Hea ng/cooling #1 ON/OFF output,


n2 : HEAT/COOL #2 output, event output event output
n3 : HEAT/COOL #3 output, event output
n4 : HEAT/COOL #4 output, event output
KIMO

DIGITAL HUMIDITY CONTROLLER

FX3H Digital Humidity Controller Humidity


FX3DH Digital Temp. & Humidity Controller NTC Heating Cooling Thermostat Humidity 4~20mA Retrans
OHKURA

FX3H 16A, 250Vac FX3DH 8(2)A, 250Vac

MODULE
OPTION
OUT1 OUT1 OUT2

POWER POWER
SEKONIC

L1 L2 COM Vin +5V L1 L2 NTC COM Vin +5V


c c

1 2 4 5 6 9 10 11 1 2 3 4 5 6 7 8 9 10 11
R R
AC100 - 240V ~ W(Y) AC100 - 240V ~ W(Y)
% Humidity 50/60Hz TEMP % Humidity
50/60Hz
B B
OUT1 : Humidifica on/dehumidifica on
OUT1: Dehumidifica on/Humidifica on #1 ON/OFF output
#1 ON/OFF output OUT2 : Humidifica on/dehumidifica on
COM : Signal input common terminal #2 ON/OFF output
HUBA

Vin : Humidity sensor input COM : Signal input common terminal


+5V : Power Supply for humidity Vin : Humidity sensor input
sensor (5Vdc) NTC : Temp. sensor input
+5V : Power for humidity sensor(5Vdc)

Humidication (heating), dehumidication (cooling) ouput, high/low


Humidication/dehumidication input, high/low alarm output, alarm output, min. on/off maintaining time setup, selection on/off
Main- min. on/off maintaining time setup, selection on/off output when Main-
output when sensor error occurs, sensor correction, sensor error
KAISE

Function sensor error occurs, sensor correction, sensor error detection, Function
detection, relay output manual control, transmission output, RS485
selection of displaying decimal point communication (MODBUS)

Power Supply AC100~240V, 50/60Hz, Max. 4VA Power Supply AC100~240V, 50/60Hz, Max. 4VA
Input/output Relay output : 1 point (out1 : 250Vac/16A), Input/output Relay output : 1 point (out1 : 250Vac/8(2)A),
CORDEX

Humidity 1~4V, input : 1 point Humidity 1~4V, input : 1 point

Sensor Spec HTX20-FTS-502 (Voltage output type humidity sensor), HTX3515 Sensor Spec HTX20-FTS-502 (Voltage output type humidity sensor), HTX3515
Models FX3H - 00 Models FX3H - 00 : Basic model
FX3DH - R4 : Add on RS485 communication (MODBUS)
FRIED ELECTRIC

FX3DH - A1 : Add on 4~20mA transmisson output


FX3DH - R2 : Add on RS232 communication

Sensing Technology Corporation 457-B Boni Avenue New Zaniga Mandaluyong City www.heatsenze.com sales@heatsenze.com Tel No. 532-0088 Fax No. 531-7387

V-A2
SENSETE°CH®
FX Series

CWC
REFRIGERATION CONTROLLER
FX32J FX32R NTC RS485

HEAT-EDGE®
Showcase & Coldroom Controller NTC RS485 4~20mA Retrans Showcase & Coldroom Controller

COMP, DEF : 10A, 250Vac FAN, AUX : 5A, 250Vac

COMP FAN DEF AUX

RAINBOW
comp: compressor(SOL) control output ID1-D.SYC: defros ng syncroniza on signal input
fan: fan control outout ID2-I.LOCK: interlock signal input
def: defros ng control output ID3-FAN.AL: fan alarm signal input

DOTECH
al/aux: alarm/defros ng synchroniza on/ ID4-EMG.C: emergency(locking) switch signal input
hea ng control output ID5-NIGHT: NIGHT SETBACK signal input
ID6-DOOR: door open switch signal input
AMB.T : inside temperature sensor ID7-REMOTE remote
: opera on stop signal input
DEF.T : sensor for return temperature a er comp: compressor(SOL) control output
B1-AMB : inside temperature sensor
sensor for defrost recovery fan: fan control outout
B2-DEF :sensor for return temperature a er
def: defros ng control output
sensor for defrost recovery
al/aux: alarm/defros ng synchroniza on/

SHIMADEN
B3-EXT : outlet temperature sensor
hea ng control output

Defrosting (auto/manual), fan control, efcient delay Defrosting (auto/manual), defrosting stop delay, evaporation fan
Main- Room temperature sensor : 1EA, defrost recovery sensor : 1EA. Main- control, air inlet/outlet sensor : 2EA, defrost recovery sensor : 1EA,
Function High (low) temp. alarm output, room temp. transmission output Function virtual temp. sensor computing, door open alarm, emergency call,
(4~20mA), RS85 communication (MODBUS) interlock, defrost activation, night operation, high (low) temp. alarm

PR ELECTRONICS
output, RS85 communication (MODBUS)
Power Supply AC100~240V, 50/60Hz, Max. 4VA, screw bolt terminals
Input/output Relay output : 4point, Temp. sensor input : 2 point Power Supply AC100~240V, 50/60Hz, Max. 8VA, connector (Molex)
Sensor Spec DPR-TH1 : NTC 5k, ±0.3°C at 25°C(-50~105°C) Relay output : 4point, Digital input : 7 point,
Input/output Temp. sensor input : 3 point
FX32J – 00 : Basic model
FX32J– R4 : Add on RS485 communication (MODBUS) FX32R– 00 : Basic model
Models FX32J– A1 : Add on 4~20mA transmission output Models

KIMO
FX32R– R4 : Add on RS485 communication (MODBUS)
FX32J– L1 : adopted printer for recoder
FX32J– L2 : added data logger function
FXP-60 recording
: printer for FX32J-L1

FX32K Defrost factor Controller Defrost 4~20mA RS485


FX32C Comptector NTC RS485

OHKURA
Defrost factor Controller Defrost 4~20mA RS485

SEKONIC
B1 : Ambient humidity 4~20mA input
ID1 : OCR comp : COMP RUN/STOP
B2 : Ambient temperature sensor input
ID2 : INT sol : SOL V/V ON/STOP
B3 :Refrigerant suc on temperature
ID3 : HPS inj : INJECTION SOL
HUBA

sensor input
ID4 : OPS / PMR al/aux : Alarm
ID1 : Interlock signal
ID5 : LPS
def : Defrost ON/OFF output ID6 : INTERLOCK B1 : AMBIENT TEMP
al/aux : Alarm output ID7 : RUN/STOP B2 : SPARE
B3 : DISCHARGE GAS TEMP

Efcient defrosting in geothermy heat pump system Total control and detection (protection) for freezers, function of start,
KAISE

Main- Defrosting execution by measuring of ambient humidity Main- restart, pump down, alarm delay timer, discharge gas detection
Function and temperature Function (high & low temp.), individual alarm message (OC, HP, LP, OP, INT, etc),
liquid injection (discharge gas detection), communication (RS485 MODBUS)

Power Supply AC100~240V, 50/60Hz, Max. 4VA, screw bolt terminals Power Supply AC100~240V, 50/60Hz, Max. 8VA, connector (Molex)
Input/output Relay output : 4point, Temp. sensor input : 2 point Input/output Relay output : 4point, Temp. sensor input : 2 point
CORDEX

Relay output : 2 point, Digital input : 1 point, Relay output : 4 point, Digital input : 7 point,
Sensor Spec Temp. sensor input : 2(3) point, humidity sensor input : 1 point Sensor Spec Temp. sensor input : 3 point
FX32K–00 : Basic model FX32C–00 : Basic model
Models FX32K–30 : Add on humidity sensor Models FX32C–30-R4 : Add on RS485 communication (MODBUS)
FRIED ELECTRIC

FX32K–30-R4 : Add on RS485 communication (MODBUS) FX32C–30 : add on gas discharge protection and control
FX32C–40 :add on added gas discharge temperature and inside
temperature control function

Sensing Technology Corporation 457-B Boni Avenue New Zaniga Mandaluyong City www.heatsenze.com sales@heatsenze.com Tel No. 532-0088 Fax No. 531-7387

V-A3
SENSETE°CH®

FX Series
CWC

REFRIGERATION CONTROLLER
FX32PR FX32EV Electronic Expansion Valve control system
HEAT-EDGE®

Digital Low/High Pressure Controller 4~20mA RS485 Retrans Pt1000 4~20mA RS485 Retrans

FX32EV

MODULE
OPTION
Alarm

EVout
RAINBOW

ID1 Pt1k COM 4~20mA +V

1 2 3 4 5 6 7 8 9 10 11

AC100 - 240V ~
50/60Hz
EV

start temp pressure

RS-485CO MM. RS-232COMM. 4~20mA Output


DOTECH

OPTION MODULE OPTION MODULE OPTIONMODULE

1 1 1
2 TRX 2 RXD 2 4~20mA
3 TRX 3 TXD 3 4~20mA
4 SG 4 GND 4 SG
SHIMADEN

Uniform step control, operation with intelligent shift PID degree of superheat control through defense and safety
Main- high/low alarm output, sensor correction, sensor error detection, Main- compensation, degree of superheat control for various refrigerant,
Function transmission output, communication (RS485 MODBUS) Function PMW (opening ratios control), remote operation, transmission output,
RS485 communication (MODBUS)

Power Supply AC100~240V, 50/60Hz, Max. 4VA Power Supply AC100~240V, 50/60Hz, Max. 4VA, screw bolt terminals
PR ELECTRONICS

Input/output One sensor input of 4~20 mA (embedded sensor loop power), Input/output SSR output 1-point (expansion valve on/off), relay output 1-point
Four relays (three relays for step control, one relay for alarm output) (alarm point), temperature sensor 1-point, 4~20mA pressure sensor
input 1-point (embedded sensor loop power)
FX32PR–00 : Basic model Sensor Spec Temp. sensor (DPR-PT1K-P6D5OL, -100~100°C
Models FX32PR–R4 : Add on RS485 communication (MODBUS) Pressure sensor (-1~9 bar or 0~30 bar)
FX32PR–A1 : Add on 4~20mA transmission output
FX32EV– 00 : Basic model
Models
FX32EV– R4 : Add on RS485 communication (MODBUS)
KIMO

FX32EV– A1use: for 4~20mA type Electronic Expansion Valve or


pressure transmission output function
FX32EV– R2 : Add on RS232 communication

FX32S series Showcase & Coldroom Controller NTC RS485


OHKURA

Defrosting (auto/manual), defrosting stop delay, two air inlet and


Main- outlet sensors, one sensor for defrost recovery, high(low) alarm
Function output, RS485 communication (MODBUS), indicator (FxiView)
SEKONIC

connection

Power Supply AC100~240V, 50/60Hz, Max. 8VA, connector (Molex)


Input/output relay output max 4-point, temperature sensor input max 3 point

Sensor Spec DPR-TH1 : NTC 5k, ±0.3°C at 25°C (-50~105°C)


HUBA

Models FX32S FX32SD FX32SA FX32SF FX32SB FX32SR


POWER POWER
FX32S CMP FX32SD CMP
1 6 1 6
Compressor 16A 16A 16A 16A 16A 8A
B1-AMB

B3-EXT

B2-DEF

B1-AMB

14 8 14 8
7 12 7 12 Defrost - 8A - - 8A 8A
G G J1 G G J1
DEF
G + G - G + G -
Eva Fans - - - 8A 8A 8A
KAISE

7 1 RS485, MODBUS 7 1 RS485, MODBUS


FX iview FX iview
J2 J2
POWER POWER Aux.output - - 8A - - 8A
FX32SF CMP FX32SB CMP
1 6 1 6
B3-EXT

B2-DEF

B1-AMB

B3-EXT

B2-DEF

B1-AMB

Room Temp. ● ● ● ● ● ●
14 8 14 8
7 12 7 12
G G G G
FAN
J1 FAN DEF
J1 Defrost Temp. - ● ● ● ● ●
G + G - G + G -
CORDEX

7 1 RS485, MODBUS 7 1 RS485, MODBUS


J2
FX iview
J2
FX iview
Digital Input
- ● ● ● ● ●
FX32SA
POWER
CMP FX32SR
POWER
CMP
(Probe3)
1 6 1 6
B3-EXT

B2-DEF

B1-AMB

B3-EXT

B2-DEF

B1-AMB

RTC - - - - - -
14 8 14 8
ALARM ALARM
G G
7
J1
12
G G
7
J1
12
RS485 ◎ ◎ ◎ ◎ ◎ ◎
FRIED ELECTRIC

FAN DEF
G + G - G + G -
7 1 RS485, MODBUS FX iview
7 1 RS485, MODBUS FX iview ● : Basic
J2 J2 ◎ : Option

Sensing Technology Corporation 457-B Boni Avenue New Zaniga Mandaluyong City www.heatsenze.com sales@heatsenze.com Tel No. 532-0088 Fax No. 531-7387

V-A4
SENSETE°CH®
FX Series

CWC
MULTI-FUNCTION DIGITAL CONTROLLER

FX32P FX32F

HEAT-EDGE®
Pressure Switch Controller 4~20mA RS485 Retrans Fan Coil Unit Controller NTC Heating Cooling RS485

FX32P N1,2 : 10A, 250V FX32F

MODULE
OPTION
N3,4 : 5A, 250V 2A 250Vac

AMB. TEMP
3wire

COIL TEMP

MODULE
OPTION
SENSOR

SENSOR
2wire
POWER

RAINBOW
L1 L2 COM mA +12V
c L1 L2 B2 G B1 G

1 2 3 4 5 6 7 8 9 10 11 1 2 3 4 5 6 7 8 9 10 11 12 13
LO MD HI COM
+ AMB
AC100 - 240V~ B/T
SENSOR TEMP
50/60Hz AC100-240V~
N1 N2 N3 N4 50/60Hz FAN

L1
L2 LO : low wind speed on/off output
N1 :decrease pressure / increase pressure MD : midium wind speed on/off output
HI : high wind speed on/off output

DOTECH
#1 ON/OFF output, event output
N2 :decrease pressure / increase pressure
#2 ON/OFF output, event output G : signal input common terminal
N3 :decrease pressure / increase pressure B1 : Ambient temperature sensor input
#3 ON/OFF output, event output B2 : coil temerature sensor input
N4 :decrease pressure / increase pressure
#4 ON/OFF output, event output

SHIMADEN
Output controllable based on measured pressure value (increase and decrease), 3 stage fan speed controllable, 4 kind (stop/high/middle/low) airow choosable,
Main- Main- unication of temp. control function, data backup, self diagnostic, RS485
alternative operation available between freezing exclusive model and booster,
Function pump unit control exclusive model, RS485 communication (MODBUS) Function communication (MODBUS)

PR ELECTRONICS
Power Supply AC100~240V, 50/60Hz, Max. 4VA, screw bolt terminals Power Supply AC100~240V, 50/60Hz, Max. 4VA, connector
Input/output relay output : 4 point, Input sensor : 1 point (including power supply) Input/output relay output : 3 point (airow control),
Temp. sensor input : 2 point (room & water)
Sensor Spec 4~20mA (2 wire or 3 wire)
FX32P– 00 : Basic model Sensor Spec DPR-TH1 : NTC 5k, ±0.3°C at 25°C (-50°C~105°C)
Models FX32P– R4 : Add on RS485 communication (MODBUS) FX32F– 00 : Basic model
FX32P– A1 : Add on 4~20mA transmission output

KIMO
Models FX32F– R4 : Add on RS485 communication (MODBUS)

FX32A Air Compressor Controller NTC 4~20mA RS485 Retrans


FX32A-351 Air Compressor Controller NTC 4~20mA RS485 Retrans

OHKURA
FX32A-351
MODULE
OPTION
3A 250Vac

SEKONIC
L1 L2 ID1 B3 B2 COM B1 +VDC
C1 C2 C

1 2 3 4 5 6 7 8 9 10 11
AC100 - 24 0V ~
50/60Hz

L1
comp : main motor on/off output L2
sol : LOAD SOL ON/OFF output B1 : pressure sensor input signal ID1 : remote run/stop signal
ID1 : control output interlock signal(OCR, EMSW) B1 : pressure sensor input signal B2 : COMP1 temp. sensor input signal C1 : COMP1 motor ON/OFF output
HUBA

ID2 : remote run / stop control signal B2 : temperature sensor input signal B3 : COMP2 temp. sensor input signal C2 : COMP2 motor ON/OFF output

Embedded run/stop switch, motor on/off, load run, auto-stop, manual Embedded run/stop switch, motor on/off, load run, auto-stop, manual
Main- stop, operation delay, load delay, embedded timer, Main- stop, operation delay, load delay, embedded timer,
Function pressure/temerature high level, temperature low level (standby for Function pressure/temerature high level, temperature low level (standby for
starting), interlock input signal (emergency switch, OCR reverse phase), starting), interlock input signal (emergency switch, OCR reverse phase),
KAISE

Usable thermometer and manometer, RS485 communication Usable thermometer and manometer, RS485 communication(MODBUS)
(MODBUS)
Power Supply AC100~240V, 50/60Hz, Max. 4VA, screw bolt terminals
Power Supply AC100~240V, 50/60Hz, Max. 4VA, screw bolt terminals
Input/output Relay output : 2 point (motor, SOL)
Input/output Relay output : 2 point (motor, SOL) Digital input : 2 point (interlock, remote control)
Temp. sensor input : 1 point (discharge air temperature)
CORDEX

Digital input : 2 point (interlock, remote control)


Temp. sensor input : 1 point (discharge air temperature) Pressure sensor input : 1 point (discharge air pressure)
Pressure sensor input : 1 point (discharge air pressure) Sensor Spec Pressure Sensor : 0~16 bar (4~200mA)
Sensor Spec DPR-TH2 : NTC 10k, ±0.3°C at 25°C (-50°C~150°C) DPR-TH2 : NTC 10k, ±0.3°C at 25°C (-50°C~150°C)
FX32A– 00 : Basic model FX32A-351-00 : Basic model
FRIED ELECTRIC

Models FX32A– R4 : Add on RS485 communication (MODBUS) Models FX32A-351-R4 : Add on RS485 communication (MODBUS)
FX32A– A1 : Add on 4~20mA transmission output FX32A-351-A1 : Add on 4~20mA transmission output
FX32A– R2 : Add on RS232 communication FX32A-351-R2 : Add on RS232 communication

Sensing Technology Corporation 457-B Boni Avenue New Zaniga Mandaluyong City www.heatsenze.com sales@heatsenze.com Tel No. 532-0088 Fax No. 531-7387

V-A5
SENSETE°CH®

DX Series
CWC

DX100 / DX120 / DX140 HVAC Controller


HEAT-EDGE®

DX100 series based on microprocessor has realized the best control and stability with efcient
control for HVAC units (AHU, constant temperature & humidity unit and control (dehumidier) and
perfect interface with safety devices. Its elegant graphic LCD display and LED helps users to check
RAINBOW

the current state of the units.

- Temperature & humidity control function, Max. 6 loop of independent step


operating function
- Alternative operation by max. 4 compressors and 8 heaters
- Backup operating function
DOTECH

- Prevention from frequent starting failure occurred by low pressure hunting using
low pressure switch in compressor
- Successive starting function, pump down function and prevention from restarting
function
- Control function for cold water, hot water, steam valve, SCR, damper designed for
HVAC (4~20mA PID control)
SHIMADEN

- Detection of error in temperature and humidity sensor, Alarm function, Output of


of equipment state (Cooling and Dehumidication, Heating and Humidication)

- DX100 : HVAC Controller (2Comp) - DX120 : HVAC Controller (4Comp) - DX140 : Exclusive controller for constant temp. and humidity unit
PR ELECTRONICS

Models Models
DX120 DX140 DX100 DX120 DX140
Main Specication Main Specication
Digital Input Port 10 10 Trip / Alarm Recording Function OK -
Digital Output Port 12 12 Schedule Run/Stop Function OK -
KIMO

Temperature Sensor Input 2 1 Cool / Dehumidify Analog Control OK (PID control) OK(P control)
Humidity Sensor Input 1 1 Cooling Analog Control OK (PID control) OK(P control)
Diff. Pressure Sensor Input 1 - Heating Analog Control OK (PID control) OK(P control)
Refrigerator Compressor Control Step 2 4 2 Humidify Analog Control OK (PID control) OK(P control)
OHKURA

Heater Control Step 7 5 Diff. Pressure Analog Control OK (PID control) OK(P control)
Humidify Control Step 4 2 Temperature Retransmission Output OK -
Dehumidify Control Step 4 - Humidify Retransmission Output OK -
Main Brower Fan on/off Control 1 1 Diff. Press. Retransmission Output OK -
- React Heater SCR on/off Control OK -
SEKONIC

Dehumidier Control Function OK


React Heater Temp. Sensor Input OK - Heater SCR on/off Control OK -
React Heater Control Function OK - Humidify Heater SCR on/off Control OK -
React Heater Control Step 4 - 4 -
Cooling State on/off Control OK -
React Fan on/off Control 1 - 1 -
HUBA

Temperature + Humidity Control Display OPERATION


▶ SET TEMPERATURE : 25.0°C
%
25.0 50.0
PV C PV SET HUMIDITY : 50.0 %
Current Temperature Current Humidity COOL DIFFERENCE : 200 Pa
MENU SELECT HEAT DIFFERENCE : 120℃
Set Temperature SP SP Set Humidity DEHUMIDITY DIFF : 1.0 ℃
25.0 50.0
KAISE

RUN INFO
OPERATION
Digital Output State CM1SL1 CM2SL2 H1 H2 H3 H4 H5 HUD ALR BRO 08:20 Current Time SCHEDULE
TRIP LOG
Opera on State LOC STP DPS. ALARM Alarm Message TRIP LOG
00 080102 15:55 FIRST POWER ON
01 080102 16:10 FAN FAULT
Digital Input State C1A LP1LP2C2A RHAAFS HUA BRA RET
08 Equipment State Code
02 080102 16:30 COMP#1 FAULT
03 080102 16:30 COMP#2 FAULT
Lock Signal 04 080102 16:45 X HEATER FAULT
CORDEX

Temperature Single Control Display Humidity Single Control Display


PV SP PV % SP % TRIP LOG STATE
25.0 50.0
C C
Current
Temperature
25.0 Set
Temp.
Current
Humidity
50.0 Set Humidity
COMP#1 FAULT ON 080102 16:30

TEMO : -20.0°C HUM : 15.0%


CM1SL1 CM2SL2 H1 H2 H3 H4 H5 ALR BRO 08:20 CM1SL1 CM2SL2 HUD ALR BRO 08:20
ID (10~1):
FRIED ELECTRIC

LOC STP STAND BY LOC STP STAND BY N (12~1):


C1A LP1LP2C2A RHAAFS BRA RET
08 C1A LP1LP2C2A AFS HUA BRA RET 08

Sensing Technology Corporation 457-B Boni Avenue New Zaniga Mandaluyong City www.heatsenze.com sales@heatsenze.com Tel No. 532-0088 Fax No. 531-7387

V-B6
SENSETE°CH®
DX Series

CWC
DX200 / DX240 / DX270 Screw Compressor Controller

HEAT-EDGE®
DX200 series based on microprocessor has realized the best control and stability with deciding
and controlling capacity adjustment timing for screw compressor and perfect interface with safety
devices.

RAINBOW
- Efcient step/stepless control, convenience for operation and inspection
- One-touch setup function (Choosing the maker -> Automatic setup according to
their basic spec.) (Bitzer, Hitachi, Refcomp, Fusheng, Hanbell, Mitsubishi, Roltec, Kobe)
- Strong timer function (Step delay, Start delay, Auto-stop delay, Restart delay,
Pump down delay)

DOTECH
-Temperature control, Pressure control (input temperature, output temperature,
Intake pressure control, Discharge gas temperature control and observation)

- DX200 : 1 Cycle Screw Compressor Controller


- DX220 : 1~2 Cycle Screw Compressor Controller
- DX240 : 1~4 Cycle Screw Compressor Controller

SHIMADEN
- DX270 : 1 Cycle Screw Compressor Controller (Step Control)
- DX200H : 1 Cycle Screw Heat Pump Compressor Controller
- DX220H : 1~2 Cycle Screw Heat Pump Compressor Controller
ㅇDX200 (Stepless)

PR ELECTRONICS
PV C SP C
OPERATION
7.0
25.5
Current Temperature
Set Temperature ▶Set Point : 10.0 ℃
1 Step Start Devia on : +3.0 ℃
D.C GAS : 14 C Discharge Gas Temperature 2 Step Start Devia on : +4.0 ℃
MENU SELECT 1 Step Stop Devia on : - 2.0 ℃
Digital Output State INCDECSTSSOL CM CY CD LIS ALR PM 08:20 Current Time
RUN INFO 2 Step Stop Devia on : - 1.0 ℃
Opera on State LOC STP STAND BY Alarm Message OPERATION
Digital Input State OCC REV LPS HPS 51 Equipment State Code TRIP LOG
TRIP LOG
TRIP & ALARM
23 000101 00:00 Low Temp Alarm

KIMO
Lock Signal 24 000101 00:00 Outlet T-Sense Fault
ㅇDX270 (Step) 25 000101 00:00 DC Gas#1 T sensor
26 000101 00:00 DC Gas#2 T sensor
PV SP 7 000101 00:00 X Low Temp Alarm
C C
7.0
25.5
Current Temperature
Set Temperature
TRIP & ALARM
D.C GAS : 14 C Discharge Gas Temperature

OHKURA
Pump(Fan) Interlock Delay : 0 sec
Digital Output State S1% S2% S3% SOL CM CY CD LIS ALR PM 08:20 Current Time Pump(Fan) Interlock Hold : 2 sec
Discharge Gas Over Temp : 105 ℃
Opera on State LOC STP GOOD START READY Alarm Message Freezing Protec on Temp : 2.0 ℃
Low Temp Alarm : 5.0 ℃
Digital Input State OCC REV LPS HPS OLS OVH FSPILRET 51 Equipment State Code

Lock Signal

SEKONIC
Wiring Diagram (DX200 : Stepless)
UIC DX200 Series 100 200

TERMINAL DESC. LEGEND LEGEND DESC. TERMINAL NO


NO
NOISE AC TRANSFORMER
FILTER AC 220V / 24V, 30VA J1 - 1 FG LOAD CONTROL J21 - 1 R1 FUSE
INCREASE SOL N1
100 G0 (NEUTRAL) 24VAC 50/60Hz LOAD CONTROL
J1 - 2 G0 CONTROLLER N2 J21 - 2 R2
DECREASE SOL
POWER INPUT
FUSE LOAD CONTROL
HUBA

J1 - 3 G N3 J21 - 3 R3
START SOL
200 G (HOT) SOL V/V J21 - 4
FOR LIQUID N4 R4
J11 - 1 +24V
B4 SPARE
AC 220V FUSE J11 - 2
50/60Hz 250VAC 5A OUTPUT COMMON 1 C1 J21 - 5
External Capcity Control J11 - 3 B5 External Capcity
4~20mAdc / 0~100% J11 - 4 AVSS Control Signal

MC for Main / PW1 N5 J22 - 1 R5


J12 - 1 B1 Inlet Temp Sensor
J12 - 2 AVSS (-40~70℃)
MC for Star(Y) / PW2 N6 J22 - 2 R6
J12 - 3 B2 Outlet Temp Sensor
J12 - 4 AVSS (-40~70℃)
MC for Delta(D) N3 J22 - 3 R7
J12 - 5 B3 DIS-GAS(-20~200℃)
SOL for Liquid Injection N8 J22 - 4 R8
Overload Main Motor
J13 - 1 ID1 Overload Main Motor
KAISE

OUTPUT COMMON 2 C2 J22 - 5


Reverse Phase Main Motor
J13 - 2 ID2 Rev-Phase Main Motor
LPS
J13 - 3 ID3 Low Press. Switch SPARE N9 J23 - 1
HPS
J13 - 4 ID4 High Press. Switch RUNNING STATE N10 J23 - 2 R10
Oil Level Switch
J13 - 5 ID5 Oil Level Switch ALARM(TOTAL) N11 J23 - 3 R11
G (HOT) PUMP
J13 - 6 IDCM1 ID COMMON 1 N12 J23 - 4 R12
ON/OFF CONTROL

Over-Temp Main Motor OUTPUT COMMON 3 C3 J23 - 5


J14 - 1 ID6 Over-Temp(INT TC)
CORDEX

Analog Option (Only DX200-X1 Model)


Overload Condensor-Fan Motor Y1 J6 - 1 +
J14 - 2 ID7 Overload Fan Motor Inlet Temp retrans.
YG1 J6 - 2 -
Interlock Pump(Fan), Flow Switch Y2 J6 - 3 +
J14 - 3 ID8 Flow Switch Outlet Temp retrans. YG2 J6 - 4 -
Overload Pump(Fan) Motor Alarm Y3 J6 - 5 +
J14 - 4 ID9 Interlock Pump DC Gas Temp retrans. YG3 J6 - 6 -
Remote Run/Stop ※ Shield Wire Use
J14 - 5 ID10 Remote On/Off Signal Connection Frame and Building
G (HOT) Ground
J14 - 6 IDCM2 ID COMMON 2

* OPTION
MMI CONNECTION TB1 - 1 GND
FRIED ELECTRIC

(Only DX200-X1 MODEL) TB1 - 2 B SYSTEM BUS RS485


TB1 - 3 A
* OPTION
EXTENTION BOARD TB2 - 1 GND
(to Slave Unit #2~#4) TB2 - 2 B LOCAL BUS RS485
TB2 - 3 A

Sensing Technology Corporation 457-B Boni Avenue New Zaniga Mandaluyong City www.heatsenze.com sales@heatsenze.com Tel No. 532-0088 Fax No. 531-7387

V-B7
SENSETE°CH®

DX Series
CWC

DX220 Screw Compressor Controller


HEAT-EDGE®

DX200 series based on microprocessor performs best operation (control) automatically according
to set condition and unit ’s operation status which conducting efcient operation of 1~2 cycle
compressor.
RAINBOW

- Stepless Capacity Control Type / built in equal control function


- Adapted wide graphic LCD, displaying Korean / English / Chinese
- Easy to analyze the cause of troubles because of storing 160 histories of trip message
- Embeded day-timer to enable energy-saving operation
- Various analog output function
DOTECH

(Outlet temperature / Discharge gas temperature transmission)


- Various applications (Chiller, CDU, Start control panel)
- User can use this model regardless of compressor’s maker
(can set up Capacity Control Type)
- User have only to input maker and setting of capacity Control valve is nished)
- DX220(H)-00 : Basic model
SHIMADEN

- DX220(H)-11 : Temperature transmission output function + RS485 communication


(Modbus RTU)
*H : Exclusive model for heat pump
PR ELECTRONICS

Screen Composition MENU Composition

OPERATION
▶ SET VALUE : 7.0 ℃
RUN DIFFERENTIAL : +1.0 ℃
STOP DIFFERENTIAL : -0.5 ℃
PV C SP : 10.0 C MENU SELECT 50% CAP. DIFFERENTIAL : +0.2 ℃
Current

25.5 RUN INFO 75% CAP. DIFFERENTIAL : -0.2 ℃


Temperature IN : 0.8 C
Set Temperature OPERATION
GAS#1 : 25 C
KIMO

TRIP LOG
GAS#1 : 45 C TRIP & ALARM
TRIP & ALARM
Digital FLOW SENSING DELAY : 60 ℃
Output State
ALR 08:20 Current Time FLOW SENSING HOLD : 5℃
DISCHARGE TEMP OVER : 115℃
Opera on State LOC STP STAND BY Alarm Message OUTLET TEMP FREEZE : 2.0℃
LOW TEMP PROTECT : 5.0℃
Equipment
51 State Code
OHKURA

TRIP LOG
Lock Signal
05 000101 00:00 COND-FAN FAULT
06 000101 00:00 COMP INT FAULT
07 000101 00:00 OUTLET SENS. FLT
08 000101 00:00 DS GAS SENS. FLT
09 000101 00:00 INLET SENS FLT

Wiring Diagram (DX220)


SEKONIC
HUBA
KAISE
CORDEX
FRIED ELECTRIC

Sensing Technology Corporation 457-B Boni Avenue New Zaniga Mandaluyong City www.heatsenze.com sales@heatsenze.com Tel No. 532-0088 Fax No. 531-7387

V-B8
SENSETE°CH®
DX Series

CWC
DX260 Multi Compressor Controller

HEAT-EDGE®
DX260 series has realized the best control and stability with ideal control of the number of
equipment, such as equal & backup operation and perfect interface with safety devices. Its elegant
graphic LCD display and LED helps users to check the current state of the units.

RAINBOW
Also, it provides users with the information about PM & trip alarm history for quick and easy treatment.

- Suitability for rack control of multi condensing unit


- Control for max. 8 compressors and 8 condensing fans
(Basic : 4 compressors + 4 condensers)
- Efcient control for the number of equipment

DOTECH
(Setting On/Off value per individuals and/or per between steps)
- Perfect equal control (Within 1 hour difference of the total accumulated operation time)
- Pressure/temperature control (Individual and/or interlocking control for intake
pressure, discharge pressure)
- Strong storing and/or monitoring function for trip alarm history/state (Max. 200 cases)

SHIMADEN
- Optimal function for condensing fan speed control (4~20mA PID control)
- Transmission output function (Pressure / Temperature transmission)
- PC monitoring system using RS485 communication based on MODBUS protocol

Applications

PR ELECTRONICS
- Multi Condensing Unit
- Multi Compressor Control

Screen Composition MENU Composition


OPERATION
▶ COMP SET VALUE : 1.8 bar
COMP STEP DIFF : +0.40 bar

KIMO
RUN/STOP DIFF : +1.00 bar
MENU SELECT FAN SET VALUE : 13.0 bar
FAN STOP DIFF : + 0.7 bar
PV SP bar RUN INFO

2.0
bar Set Low
Current
Low Pressure 2.0 Pressure
OPERATION
SCHEDULE
TRIP LOG
TRIP LOG
bar High Pressure 00 080102 15:55 POWER ON FIRST
HPrs 12.3 01 080102 16:10 COMP#1 FAULT

OHKURA
02 080102 16:30 COMP#2 FAULT
Digital Output State C1 C2 C3 C4 F1 F2 F3 F4 N9 N10 N11 N12 08 :20 Currrent Time 03 080102 16:30 COMP#3 FAULT
04 080102 16:45 X COMP#4 FAULT
Opera on State LOC STP STAND BY Alarm Message

CA1 CA2 CA3 CA4 FA1 FA2 FA3 FA4 ILC RET Equipment
Digital Input State 06 State Code TRIP LOG STATE
Lock Signal COMP#1 FAULT 080102 16:30

SEKONIC
LP : -1.00bar HP : 0.0bar
ID (10~1):
N (12~1):

Wiring Diagram (DX230)


AC 24V, 50/60Hz
UIC DX260 Series Controller
G G0
TERMINAL DESC. LEGEND LEGEND DESC. TERMINAL NO
NO
NOISE AC TRANSFORMER
HUBA

AC 220V / 24V, 50 VA COMPRESSOR #1 J21 - 1


FILTER J1 - 1 FG ON/OFF CONTROL N1 R1
SURGE
ABSORBER 100 G0 (NEUTRAL) 24VAC 50/60Hz COMPRESSOR #2 FUSE
J1 - 2 G0 CONTROLLER ON/OFF CONTROL N2 J21 - 2 R2 3A
POWER INPUT
J1 - 3 G COMPRESSOR #3 N3 J21 - 3 R3
ON/OFF CONTROL
200 LOW PRESSURE COMPRESSOR #4 N4
G (HOT) J21 - 4 R4
-1.0 ~ 9.0 bar J11 - 1 +24V LOW PRESSURE ON/OFF CONTROL
AC 220V FUSE J11 - 2 B4 (4~20mA)
50/60Hz 250VAC 5A 3A OUTPUTCOMMON 1 C1 J21 - 5
HIGH PRESSURE J11 - 3 B5 HIGH PRESSURE
J11 - 4 GND (4~20mA)
0.0 ~ 30.0 bar
CONDENSER #1 R5
J12 - 1 B1 TEMP INPUT ON/OFF CONTROL N5 J22 - 1
J12 - 2 GND -40 ~ 70℃ CONDENSER #2 R6
J12 - 3 B2 SPARE TEMP ON/OFF CONTROL N6 J22 - 2
J12 - 4 GND CONDENSER #3
SPARE TEMP N7 J22 - 3 R7
ON/OFF CONTROL
KAISE

J12 - 5 B3
CONDENSER #4 N8 J22 - 4 R8
Compressor #1 Alarm ON/OFF CONTROL
J13 - 1 ID1 COMP#1 ALARM
OUTPUT COMMON 2 C2 J22 - 5
Compressor #2 Alarm
J13 - 2 ID2 COMP#2 ALARM
Compressor #3 Alarm TOTAL ALARM
J13 - 3 ID3 COMP#3 ALARM N9 J23 - 1 R9
STATE SIGNAL
Compressor #4 Alarm COMP RUN/STOP
J13 - 4 ID4 COMP#4 ALARM N10 J23 - 2 R10
STATE SIGNAL
Condenser #1 Alarm COMP ALL ALARM
J13 - 5 ID5 FAN#1 ALARM N11 J23 - 3 R11
STATE SIGNAL
G (HOT) SYSTEM RUN/STOP N12
J13 - 6 IDC1 ID COMMON J23 - 4 R12
STATE SIGNAL

OUTPUT COMMON 3C3 J23 - 5


CORDEX

Condenser #2 Alarm
J14 - 1 ID6 FAN#2 ALARM
* Optional Spec.
Condenser #3 Alarm MULTI FUNCTION Y1 J6 - 1
J14 - 2 ID7 FAN#3 ALARM ANALOG#1(4~20mA) YG1 J6 - 2
Condenser #4 Alarm MULTI FUNCTION Y2 J6 - 3
J14 - 3 ID8 FAN#4 ALARM ANALOG#2(4~20mA) YG2 J6 - 4
Interlock Alarm MULTI FUNCTION Y3 J6 - 5
J14 - 4 ID9 INTERLOCK ALARM ANALOG#3(4~20mA) YG3
J6 - 6
Remote Signal * MULTI - FUNCTION CONTROL (Selctable User)
J14 - 5 ID10 REMOTE ON/OFF
MULTI FUNCTION (N9~N12)
G (HOT)
J14 - 6 IDC2 ID COMMON * OFF
* RUN STATE
* Optional Spec. * RUN WAIT STATE
MMI CONNECTION TB1 - 1 SG * COMP RUN
FRIED ELECTRIC

RS-485 (MODBUS) TB1 - 2 B SYSTEM BUS RS485 * FAN RUN


TB1 - 3 A * TOTAL ALARM
* Optional Spec. * COMP ALARM
* FAN ALARM
TB2 - 1 SG * COMP ALL ALARM
EXTENTION BOARD TB2 - 2 B LOCAL BUS RS485 * FAN ALL ALARM
TB2 - 3 A

Sensing Technology Corporation 457-B Boni Avenue New Zaniga Mandaluyong City www.heatsenze.com sales@heatsenze.com Tel No. 532-0088 Fax No. 531-7387

V-B9
SENSETE°CH®

DX Series
CWC

DX230H Geothermy Heat Pump Controller


HEAT-EDGE®

DX230H which is an optimal control algorism designed for heat pump system has realized the best
control and stability with ideal control and perfect interface with safety devices. Its elegant graphic
LCD display and LED helps users to check the current state of the units. Also, it provides user with the
RAINBOW

information about PM & trip alarm history for quick and easy treatment.

- Basic built-in control function for 1 cycle, 1~2 cycle


- Embedding the best control algorism for heat pump system
- Observation for input temperature of heat source & output temperature
(Generating alarm & trip against high & low temperature)
DOTECH

- Observation for input control temperature & output temperature


(Generating alarm & trip against high & low temperature)
- Observation & control for discharge gas temperature (Liquid injection function embedded)
- 4-way valve control and/or selected operation for cooling and heating
- Sequential and alternative operation in case of 2 cycle control
SHIMADEN

- Strong storing and/or monitoring function for trip alarm history/state (Max. 160 cases)
- Transmission output (Temperature transmission)
- PC monitoring system using RS485 communication based on MODBUS protocol

Applications
PR ELECTRONICS

- Geothermy & Water-cooled Heat Pump


- Air-cooled Heat Pump
- Waste Heat Recovery Pump

Screen Composition MENU Composition


OPERATION
▶ COOL SET VALUE : 7.0 ℃
KIMO

COOL SET VALUE NIGHT : 7.0 ℃


COOL RUN DIFFERENTIAL : +1.0 ℃
MENU SELECT HEAT SET VALUE 30.0
: ℃
PV SP HEAT RUN DIFFERENTIAL :-1.0 ℃

7.5
C C

45
RUN INFO
Current Set Temperature
Temperature OPERATION
Geothermy SCHEDULE
Output TRIP LOG
GEO TEMP. : 24.8 C TRIP LOG
Temperature 00 080102 15:55 POWER ON FIRST
OHKURA

01 080102 16:10 POWER ON


Digital Output State SOLCM CY CD LIS ALR 4W PM 08: 20 Current Time 02 080102 16:30 COMP OCR
03 080102 16:30 POWER OFF
Opera on Mode LOC STP HEAT DAY GOOD STAND BY Alarm Message 04 080102 16:45 X COMP OCR

Equipment
Digital Input State OCCOPSINT HPSLPS HCS FSPILRET 02 State Code
TRIP LOG STATE
Run/Stop Hea ng, Day/Night Equipment State Lock Signal
SEKONIC

State Cooling opera on State (Failure, Alarm, Maintain) COMP OCR 080102 16:30
OPERATING(Y/D) GEO TEMP. : 24.8℃
State OUT : 15.0℃ HP : 12.1℃
ID (10~1):
N (12~1):

Wiring Diagram (DX230)


AC 110V, 50/60Hz
UIC DX230H Series Controller after Noise filter Output Terminal
T1 N1
TERMINAL DESC. LEGEND LEGEND DESC. TERMINAL NO
NO
AC TRANSFORMER
HUBA

NOISE MAIN SOL #1


AC 220V / 24V, 30VA J1 - 1 FG J21 - 1 SOL1
SURGE
FILTER ON/OFF CONTROL N1
ABSORBER T1 G0 (NEUTRAL) 24VAC 50/60Hz
T J1 - 2 G0 CONTROLLER COMP #1 MAIN/PW1 J21 - 2 FUSE
POWER INPUT ON/OFF CONTROL N2 CM1 3A
COMP #1 STAR/PW2 J21 - 3
J1 - 3 G ON/OFF CONTROL N3 CY1

N N1 G (HOT) COMP #1 DELTA N4 J21 - 4 CD1


J11 - 1 +VDC ON/OFF CONTROL
Inlet Temp Sensor
AC 220V FUSE J11 - 2 B4
50/60Hz 250VAC 5A 3A OUTPUT COMMON 1C1 J21 - 5
J11 - 3 B5 Geo-Inlet Temp Sensor
J11 - 4 GND
N5 J22 - 1
J12 - 1 B1 Outlet Temp Sensor
J12 - 2 GND
N6 J22 - 2
J12 - 3 B2 Geo-outlet Temp Sensor
J12 - 4 GND L.INJECTIN SOL
DC GAS TEMP N3 J22 - 3 X7
KAISE

J12 - 5 B3 ON/OFF SIGNAL


N8 J22 - 4
OCR OVERLOAD
J13 - 1 ID1
MAIN MOTOR
OUTPUT COMMON 2C2 J22 - 5
OPS
J13 - 2 ID2 OIL PRESS ALARM
INT NIGHT MODE
J13 - 3 ID3 INT. THERMO ALARM N9 J23 - 1 X9
ON/OFF SIGNAL
LPS COMPRESSOR
J13 - 4 ID4 LOW PRESS SWITCH ALARM SIGNAL N10 J23 - 2 X10
HPS
J13 - 5 ID5 HIGH PRESS SWITCH 4 WAY SOL N11 J23 - 3 X11
ON/OFF CONTROL
G (HOT) BROWER (Pump) N12
J13 - 6 IDC1 ID COMMON 1 J23 - 4 X12
ON/OFF CONTROL
CORDEX

OUTPUT COMMON 3C3 J23 - 5


J14 - 1 ID6 Spare
* Optional Spec.
COOL / HEAT SWITCH COOL / HEAT-ON Inlet Temp reTrans. Y1 J6 - 1 +
J14 - 2 ID7 SWITCH ANALOG#1(4~20mA)YG1 J6 - 2 -
Interlock Pump(Fan), Flow Switch Outlet Temp reTrans. Y2 J6 - 3 +
J14 - 3 ID8 FLOW SWITCH ANALOG#2(4~20mA)YG2 J6 - 4 -
Overload Pump(Fan) Motor Alarm Geo-Outlet Temp Y3 J6 - 5 +
J14 - 4 ID9 PUMP(FAN) ALARM
ANALOG#2(4~20mA)YG3 J6 - 6 -
Remote Run / Stop
J14 - 5 ID10 REMOTE ON/OFF
G (HOT)
J14 - 6 IDC2 ID COMMON 2 ※ Shield Wire Use
Connection Frame and Building
* Optional Spec. Ground
FRIED ELECTRIC

MMI CONNECTION TB1 - 1 SG


RS-485 (MODBUS) TB1 - 2 B SYSTEM BUS RS485
TB1 - 3 A
* Optional Spec.
TB2 - 1 SG
EXTENTION BOARD TB2 - 2 B LOCAL BUS RS485
TB2 - 3 A

Sensing Technology Corporation 457-B Boni Avenue New Zaniga Mandaluyong City www.heatsenze.com sales@heatsenze.com Tel No. 532-0088 Fax No. 531-7387

V-B10
SENSETE°CH®
DX Series

CWC
DX540H Air-Source Heat Pump Controller

HEAT-EDGE®
UIC DX540H is a ideal controller for air source heat pump. It is based on microprocessor and
designed with algorithm optimised for air source heat pump. UIC DX540H operates efciently and
manages intensively refrigerant compressor of heat pump. It promotes energy-saving through judge

RAINBOW
and control timing of capacity regulation. UIC DX540H is a system to prevent occurrence of
problem by alarming and inform of necessary maintenance.

- Adoption RISC MICOM with high reliability


- Large graphic LCD which can display in Korean, English and Chinese
- Easy to maintain and analyse troubles of equipment by storing 160 trip alarms log

DOTECH
- The best calculation function of defrosting timing by various combination of 8 sources
- Embedded day-timer to enable energy-saving operation
- Easy expansion due to various analog transmission output function
- Alarm function to inform of time to maintain and change expendables through
automatic calculation
- Additional state output 4 relays for suction temperature, water temperature,

SHIMADEN
evaporation temperature, etc.

Applications
- Air source heat pump

PR ELECTRONICS
Screen Composition MENU Composition

OPERATION
▶HEAT SET VALUE : 7.0°C
HEAT SET VALUE : -50.0°C
STEP1 OP DEV. : -2.0°C
STEP2 OP DEV. : -3.0°C
MENU SELECT STEP2 STOP DEV : 0.0°C

KIMO
Temperature,
C TSUC 50.0℃ RUN INFO
Current Temperature Operation
OPERATION

24.5
(Inlet/Outlet)
TIN 24.5℃ Time Info
SCHEDULE
TOUT 26.0℃ TRIP LOG
TRIP LOG
TAMB 7.7℃ 00 080102 15:55 INLET FAULT
01 080102 16:10 OUTLET FAULT
02 080102 16:30 OUT AIR FAULT
Digital Output State C1 C2 SOL DEF 4W PM 0820
: Current Time
03 080102 16:30 DISCHARGE FAULT

OHKURA
04 080102 16:45 X EVAPO. FAULT
Operation State LOC STP Discharge Fault Alarm Message

Digital Input State OC1 LPS HPSOC2 ID5 FSL HCS RET 02 Equipment State Code
TRIP LOG STATE
Heating/Cooling State Lock Signal EVAPO.FAULT 0909102 16:30
STATE : STAND BY
Tsuc. - 40.0 bar Tsp 0.0°C
ID (10~1) :
N (12~1) :

SEKONIC
Wiring Diagram (DX540H)
HUBA
KAISE
CORDEX
FRIED ELECTRIC

※ Recommended commnunication cables


BELDEN 8761 or 9842

Sensing Technology Corporation 457-B Boni Avenue New Zaniga Mandaluyong City www.heatsenze.com sales@heatsenze.com Tel No. 532-0088 Fax No. 531-7387

V-B11
SENSETE°CH®

HTX Series
CWC

Economical Module Type Temperature


HTX20 Series
HEAT-EDGE®

and HumiditySensor

HUMITRON® HTX20 series,OEM type product line, are modules for sensing temperature and humidity with reasonable price, high precision and high quality. They are ideal for various
application because of excellent stability. Their design reminds shuttle spacecraft. They are intended to minimize spatial constraints through compact-slip design when installed on HVAC or
control equipment. HUMITRON® HTX20 series are plug connection type. They can detect relative humidity, temperature and dew point by measuring.
RAINBOW

Features
Integration of temperature and humidity measurement function
Easy to be applied to the system
Compatibility plug-In design
DOTECH

Easy to install, Compact design, Slim size


3m cable for free

Applications
Thermo-hygrostat, Humidier / Dehumidiers
SHIMADEN

Automation equipment / Equipment appliance / Medical appliances


Air supply and exhaust equipment
Equipment to collect temperature and humidity data
Technical data & Model
PR ELECTRONICS

- Range : 0~100%RH / -10~60°C - Accuracy : ±3.0%RH / ±0.5°C


- Output : 4~20mA (2 wire) - Power input : 9~32Vdc / 12~24Vac

HTX20-FTS-502 : Humidity(1~3.6V), NTC5Kohm Passive


HTX20-FTS-103 : Humidity(1~3.6V), NTC10Kohm Passive
HTX20-FTS-1K : Humidity(1~3.6V), NTC1Kohm Passive
HTX20-FTS-PT100 : Humidity(1~3.6V), Pt100ohm Passive
KIMO

HTX20-FTS-PT100 : Humidity(1~3.6V), Pt1000ohm Passive


“Direct Connection with a Thermal Element” means all of PT100, PT1000, NI1000, NTC5K and NTC10K are available.

HTX23 Series OEM Temperature and Humidity Sensor


OHKURA

HUMITRON® HTX23 series is a module for detection of temperature and humidity which is especially for OEM and satisfactory in aspects of price and quality. It provides users with 4~20mA
standard interface and it is designed with compact and slim shape, so users don’t need to consider any spatial restriction or exposure when it is installed inside or outside of various types of
climate control units or control facilities. Also, it can help users to reduce unnecessary cost and to minimize works efciency through to reduce unnecessary cost and to maximize works efciency
SEKONIC

through combination of 4~20mA standard humidity output and various temperature outputs (including passive) according to users’ needs.

Features
Unied function for measuring temperature & humidity.
Easy installation
Compact & slim size – 63(L) x 63(W) x 16(H) (mm)
HUBA

Free 2m standard cable

Applications
Constant temperature & humidity control
Temperature & humidity data collection
KAISE

Humidier & dehumidier


Ventilation facility
Technical data & Model
- Range : 10~90%RH / -10~60°C - Accuracy : ±3.0%RH / ±0.5°C
- Output : 4~20mA (2 wire) - Power input : 12Vdc(6~30Vdc)
CORDEX

HTX23 – FHC : Humidity (4~20mA)


HTX23 – FBC : Temperature (4~20mA)
HTX23 – FPC – PT100 Humidity
: (4~20mA), Direct connection with a thermal element (Passive)
FRIED ELECTRIC

HTX20 – FBS – PT100 : Direct connection with a thermal element (Passive)


HTX20 – FTS – 1K : Humidity (1~4V), Temperature (Direct connection with NTC1K (Passive)
“Direct Connection with a Thermal Element” means all of PT100, PT1000, NI1000, NTC5K and NTC10K are available.

Sensing Technology Corporation 457-B Boni Avenue New Zaniga Mandaluyong City www.heatsenze.com sales@heatsenze.com Tel No. 532-0088 Fax No. 531-7387

V-C12
SENSETE°CH®
HTX Series

CWC
Ultra-precise Indoor Type Temperature
HTX500 Series

HEAT-EDGE®
and Humidity Transmitter

HUMITRON® HTD500 series is an ultra-precise temperature & humidity transmitter for environmental measuring which integrates micro processor with a digital sensor based on MEMS
technology. It makes precise control and efcient observation possible by transmitting measured temperature and humidity information to analogue output , control and obser vation system
through RS485 communication function in real-time. Also, it supplies users excellent attention even at wide place by applying for a bog sized FND.

RAINBOW
Features
Digital sensor applied for MEMS technology
Embedded RS485 communication port based on MODBUS RTU/ASCII
Excellent long-term stability and self-digital correction

DOTECH
Quick counteraction speed (within 4 sec.)
Slim size – 310(L) x 280(H) x 45(D) (mm)

Applications
Clean room / Measuring center / Inspection room

SHIMADEN
Food company / Pharmaceutical company R&D center, Process control
Wall-Unit Computer room / Storage monitoring system
Storage for foods, medicines, cereals, woods and electronic devices
Technical data & Model

PR ELECTRONICS
Range : 5~95%RH / -10~60°C
Accuracy – HTD520 : ±1.8%RH / ±0.3°C – HTD520 : ±3.0%RH / ±0.5°C
Output : 4~20mA, RS485 communication (MODBUS RTU/ASCII)
Power input : 24VDC (Free adaptor supplied)

HTD530 – 00 : Display only Remote Probe-Unit


HTX530 – 11 : Humidity (4~20mA), Temperature (4~20mA), RS485 communication

KIMO
HTD520 – 00 : Display only
HTX520 – 11 : Humidity (4~20mA), Temperature (4~20mA), RS485 communication

Analog Voltage Relative


HTX3515

OHKURA
Humidity Module (1.0~3.6V output)

HTX3515 is a dedicated humidity and play transducer designed for OEM applications where a reliable and accurate measurement is needed. Direct interface with a micro-controller is made
possible with the module’s humidity linear voltage. HTX3515 is designed for high volume and demanding applications.

SEKONIC
Applications
Reliability not affected by repeated condensations
Demonstrated reliability and long term stability
Typical 1 to 3.6 Volt DC output for 0 to 100% RH at 5VDC supply
HUBA

Humidity calibrated within +/-3%RH @ 55%RH


Operation Temperature : -40°C to 110°C
1.5mm Pitch Side Connector(JST)
Size : 27 x 12 x 7 mm
Product free from Lead, Cr(6+), Cd and Hg. Compliant with RoHS
KAISE

Cable
1 : Black - humidity sensor power 0V
2 : Red - himidity power+5V
4 : White - Signal output for humidity measurement
CORDEX
FRIED ELECTRIC

Sensing Technology Corporation 457-B Boni Avenue New Zaniga Mandaluyong City www.heatsenze.com sales@heatsenze.com Tel No. 532-0088 Fax No. 531-7387

V-C13

You might also like