You are on page 1of 3

TABLE 1 TABLE 2 - COIL DATA

VALVE PORT CONNECTION NOMINAL VOLTAGE APPLIED VOLTAGE AMPERES VA VA COIL


"A" "B" "C" "D" WATTS
TYPE SIZE SIZE & FREQUENCY & FREQUENCY INRUSH HOLDING INSULATION 3.47
INRUSH HOLDING
200RD4P2
24/50 2.0 .96 12.0 48 23
200RD4P2M 1/4 NPTF 24/50-60 .68
24/60 1.6 .74 8.3 38 18
200RD4P2T
.25 120/50 .45 .21 12.6 53 25
200RD4P3 120/50-60
120/60 .36 .16 9.0 43 19
200RD4P3M
208/50 .19 .08 8.0 40 17
200RD4P3T CLASS F
--- --- 208-220/208-240 208/60 .15 .06 7.0 32 12 1.81
200RD5P3 50/60 240/50 .24 .10 12.0 57 24
200RD5P3M .31 3/8 NPTF 1.18 2.37
240/60 .19 .08 9.0 46 19
200RD5P3T
480/50 .11 .05 12.0 53 24
200RD6P3 480/50-60
480/60 .09 .04 9.0 43 19
200RD6P3M .37
200RD6P3T
200RD4S3
200RD4S3M 3/8 ODF .50 1.37
200RD4S3T
200RD4F3
3/8 SAE
200RD4F3M .25 --- 1.56 3.12 --- 2" REQUIRED FOR
MALE FLARE
200RD4F3T COIL REMOVAL
200RD4S4 1.77
200RD4S4M
200RD4S4T
200RD5S4
200RD5S4M .31 1/2 ODF .56 1.18 2.37 1.25 .85
200RD5S4T
200RD6S4
200RD6S4M .37
200RD6S4T 3.41
200RD5F4
200RD5F4M .31
200RD5F4T 1/2 SAE
--- 1.75 3.50 --- .87 KNOCKOUT
200RD6F4 MALE FLARE
(BOTH SIDES) .59
200RD6F4M .37
200RD6F4T 1.00
200RD4S3 SHOWN
200RD5S5 VALVE LESS COIL (VLC)
1.18
200RD5S5M .31
200RD5S5T
5/8 ODF .56 1.18 2.37 1.25 "A"
200RD6S5
200RD6S5M .37 "B"
200RD6S5T "D"
200RD5F5
"C"
200RD5F5M .31
200RD5F5T 5/8 SAE
1.87 3.75
200RD6F5 MALE FLARE
200RD6F5M .37
200RD4S3 SHOWN
SAE MALE FLARE WITH CLIP STYLE COIL
200RD6F5T --- --- CONNECTIONS
200RD2F2 .154 4.18
1/4 SAE 1.39 2.76
200RD3F2 (OVERALL HEIGHT)
.18
200RD3F3 3/8 SAE 1.56 3.12
200RD4F4T .250
1/2 SAE 1.75 3.50
200RD3F4T .18
1.37 5.00
(OVERALL HEIGHT)
07 AGENCY APPROVALS: .77 1.93
U.L./cUL FILE NO. MP604; U.L. GUIDE NO. Y10Z .52

06 MAX. FLUID TEMP.: 250°F

05 S.W.P.: 680 PSIG


MOUNTING STUD OPTION
04 M.O.P.D.: 550 PSI
MANUAL STEM OPTION
1.5:1
MATERIAL SCALE DRAWN
03 COIL LEAD WIRE: 1/32 THK INSULATION RATED FOR 600V & 125°C. DO NOT SCALE DRAWING
UNLESS OTHERWISE
SPECIFIED:
ALL DIMENSIONS
DRAWING DATE
05-04-10
DHG
02 COIL LEAD LENTH: 6" ARE IN INCHES CHECKED

D
REMOVE ALL BURRS DRAWING SIZE

MRG
BREAK SHARP EDGES .010 MAX TITLE
INSIDE RADII .015 MAX FINISH
THIS PRINT IS THE PROPERTY OF EMERSON CLIMATE
MACHINED SURFACE
FINISH 125 MAX
EWR NO.
103433
200RD
01 COILS ARE NORMALLY SUPPLIED WITH A JUNCTION BOX (AMG TYPE). TECHNOLOGIES FLOW CONTROLS. IT IS ON LOAN FOR
TOLERANCES
.X ± .1
APPROVED
VALVE SERIES
06-02-10 MRG
RELEASE DATE
CONFIDENTIAL USE, SUBJECT TO RETURN ON REQUEST .XX ± .02
.XXX ± .005
AND WITH THE MUTUAL UNDERSTANDING THAT IT WILL ANGLES ± 1 ° PRECEDING EWR NO.

NOTES: NOT BE USED IN ANY MANNER DETRIMENTAL TO THE DIAMETERS SHOWN ON A COMMON
CENTERLINE TO BE CONCENTRIC SHEETS
REVISION DRAWING NO.

INTERESTS OF EMERSON CLIMATE TECHNOLOGIES. WITHIN .010 T.I.R.


MAJOR PER SEP 200-7
CRITICAL PER SEP 200-7
SUPERSEDES
1 of 3 F200RD
TABLE 1
VALVES WITH EXTENDED ENDS
VALVE PORT CONNECTION
"A" "B" "C" "D"
TYPE SIZE SIZE
200RD5T3
200RD5T3T .31
200RD5T3M
3/8 ODF .31 2.31 4.62 4.00
200RD6T3
3.47
200RD6T3T .37
200RD6T3M .68
200RD4T4
200RD4T4T .25
200RD4T4M
200RD5T4
200RD5T4 BF 1.81
.31 1/2 ODF .38 2.50 5.00 4.24
200RD5T4T
200RD5T4M
200RD6T4
200RD6T4T .37
200RD6T4M
200RD4T5
200RD4T5T .25
200RD4T5M
200RD5T5
200RD5T5 BF
.31
200RD5T5T 5/8 ODF .50 3.25 6.50 5.50
200RD5T5M
200RD6T5
2" REQUIRED FOR
200RD6T5 BF COIL REMOVAL
.37
200RD6T5T 1.77
200RD6T5M 1.00
200RD4T4 SHOWN
1.18 VALVE LESS COIL (VLC)
.85

3.41

.87 KNOCKOUT
(BOTH SIDES)
.59

"A"
"B"
4.18
(OVERALL HEIGHT) "D"
OF CONNECTION

"C"

1.37 5.00 200RD4T4 SHOWN


(OVERALL HEIGHT) WITH CLIP STYLE COIL
.77 1.93
.52

MOUNTING STUD OPTION

1.5:1
MATERIAL SCALE DRAWN
DO NOT SCALE DRAWING
MANUAL STEM OPTION UNLESS OTHERWISE
DRAWING DATE DHG
SPECIFIED:
ALL DIMENSIONS 05-04-10
ARE IN INCHES CHECKED

D
REMOVE ALL BURRS DRAWING SIZE

MRG
BREAK SHARP EDGES .010 MAX TITLE
INSIDE RADII .015 MAX FINISH
THIS PRINT IS THE PROPERTY OF EMERSON CLIMATE
MACHINED SURFACE
FINISH 125 MAX
EWR NO.
103433 APPROVED
200RD
VALVE SERIES
TOLERANCES
TECHNOLOGIES FLOW CONTROLS. IT IS ON LOAN FOR .X ± .1

06-02-10 MRG
RELEASE DATE
CONFIDENTIAL USE, SUBJECT TO RETURN ON REQUEST .XX ± .02
.XXX ± .005
AND WITH THE MUTUAL UNDERSTANDING THAT IT WILL ANGLES ± 1 ° PRECEDING EWR NO.
DIAMETERS SHOWN ON A COMMON
NOT BE USED IN ANY MANNER DETRIMENTAL TO THE CENTERLINE TO BE CONCENTRIC SHEETS
REVISION DRAWING NO.

INTERESTS OF EMERSON CLIMATE TECHNOLOGIES. WITHIN .010 T.I.R.


MAJOR PER SEP 200-7
CRITICAL PER SEP 200-7
SUPERSEDES
2 of 3 F200RD
TABLE 1
VALVES W/EXTENDED ENDS (1/4, 3/8 & 1/2 ODF CONNECTIONS)
VALVE PORT CONNECTION
"A" "B" "C" "D" 3.47
TYPE SIZE SIZE
200RD3T3 .68
.18
200RD3T3 BF
200RD4T3
.25
200RD4T3 BF 3/8 ODF
200RD3T3T .18
200RD4T3T .32 4.03 1.81
.25
200RD4T3M 2.42 4.67
200RD2T2 1/4 ODF
200RD2T3 3/8 ODF
.154
200RD2T2T 1/4 ODF
200RD2T3T 3/8 ODF
200RD3T4 1/2 ODF .38 3.91
.18
200RD3T2 1/4 ODF .32 4.03

2" REQUIRED FOR


COIL REMOVAL
1.77

.85

3.41

.87 KNOCKOUT
(BOTH SIDES)
.59

1.00
200RD4T3 SHOWN "A"
1.18 VALVE LESS COIL (VLC)
"B"

"D"

"C"

200RD4T3 SHOWN
WITH CLIP STYLE COIL

4.18
(OVERALL HEIGHT)
OF CONNECTION

1.37 5.00
(OVERALL HEIGHT)
.77 1.93
.52

MOUNTING STUD OPTION


1.5:1
MATERIAL SCALE DRAWN
DO NOT SCALE DRAWING
UNLESS OTHERWISE
SPECIFIED: DRAWING DATE DHG
MANUAL STEM OPTION ALL DIMENSIONS
ARE IN INCHES
05-04-10
CHECKED

D
REMOVE ALL BURRS DRAWING SIZE

MRG
BREAK SHARP EDGES .010 MAX TITLE
INSIDE RADII .015 MAX FINISH
THIS PRINT IS THE PROPERTY OF EMERSON CLIMATE
MACHINED SURFACE
FINISH 125 MAX
EWR NO.
103433 APPROVED
200RD
VALVE SERIES
TOLERANCES
TECHNOLOGIES FLOW CONTROLS. IT IS ON LOAN FOR .X ± .1

06-02-10 MRG
RELEASE DATE
CONFIDENTIAL USE, SUBJECT TO RETURN ON REQUEST .XX ± .02
.XXX ± .005
AND WITH THE MUTUAL UNDERSTANDING THAT IT WILL ANGLES ± 1 ° PRECEDING EWR NO.
DIAMETERS SHOWN ON A COMMON
NOT BE USED IN ANY MANNER DETRIMENTAL TO THE CENTERLINE TO BE CONCENTRIC SHEETS
REVISION DRAWING NO.

INTERESTS OF EMERSON CLIMATE TECHNOLOGIES. WITHIN .010 T.I.R.


MAJOR PER SEP 200-7
CRITICAL PER SEP 200-7
SUPERSEDES
3 of 3 F200RD