You are on page 1of 20
FL and FLS Gate Valve T1482 @ cameron All information contained in this manual is the exclusive property of Cameron. Any repro- duction or use of calculations, drawings, photographs, procedures or instructions, either expressed or implied, is forbidden without written permission of Cameron or its authorized agent. Revision 07 December 2008 Revision 08 December 2009 Produced by Technical Publications, Houston, TX, USA. © 2009 Cameron re148-2 2 @ cameron PREFACE The procedures included in this book are to be performed in conjunction with the requirements and recommendations outlined in API Specifications. Any repairs to the equipment covered by this book should be done by an authorized Cameron service representative. Cameron will not be responsible for loss or expense resulting from any failure of equipment or any damage to any property or death or injury to any person resulting in whole or in part from repairs performed by anyone other than authorized Cameron personnel. Such unauthorized repairs shall also serve to terminate any contractual or other warranty, if any, on the equipment and may also result in equipment no longer meeting applicable requirements. File copies of this manual are maintained. Revisions and/or additions will be made as deemed necessary by Cameron. The drawings in this book are not drawn to scale, but the dimensions shown are accurate. This book covers Cameron products. Cameron P.O. Box 1212 Houston, Texas 77251-1212 713-939-2211 httpuwww.c-a-m.com re148-2 3 @ cameron 10, re148-2 GENERAL WARNING READ AND UNDERSTAND ALL INSTRUCTIONS. Failure to follow may result in serious personal injury and damage not only to equipment but also the environment. Safety is a combination of staying alert, common sense, and experience with oil field equipment and environment. Read this manual prior to operating and servicing the FL and FLS valve. Be familiar with operation terminologies of gate valves and oil field equipment. This document includes basic valve repair guidance. The field service personnel shall be fully trained in all aspects of handling pressure control equipment as well as the job they are going to perform on the FL and FLS valve models. If any procedures and policies listed in this document cannot be followed, contact a Cameron Representative for best course of action, Proper Personal Protective Equipment (PPE) shall be utilized according to Company policies. Always use proper tools when servicing equipment ‘A Job Hazard Analysis (JHA) must be performed prior to beginning service on a well location. A JHA review meeting will be held with all affected rig personnel PRIOR to commencement of work to review results of the JHA, evacuation routes, emergency contacts, etc. All meeting attendees and a Company Representative will sign off on the JHA to acknowledge meeting has taken place. Be aware of unexpected circumstances that may arise when operating or servicing valve. Utilize Step Back 5X5 process in order to assess hazards posed before, during and after servicing of ‘equipment under pressure or with potential of hazardous chemicals present. Be familiar with company’s and facility's Lockout/Tagout program in order to ensure all sources of energy (ice. electrical, pneumatic, pressure) are isolated and/or de-energized prior to beginning work. All governmental or Company safety requirements shall be met before working on valve. Requirements of fully tested pressure barriers prior to servicing valve shall be observed. ‘Cameron recommends two mechanical pressure barriers is preferred practice. Lower Master Valve (LMV)is a critical valve and additional precautions should be taken to ensure mechanical pressure barriers are functioning correctly prior to work being carried out on this particular valve. ‘Always check for trapped pressure before servicing valve. All valves downstream of pressure barriers must be cycled several times to release trapped pressure. Ensure chemical and physical properties of fluid flow product inside valve are known. Obtain applicable Material Safety Data Sheets (MSDS) for commonly encountered chemicals such as hydrogen sulfide, cements, etc. in order to identify appropriate PPE to use, emergencies, procedures, and methods or exposure control. Always use correct lifting devices and follow safety rules in handling heavy products. The weight of single cavity flanged and hub outlet valves are provided in this document for reference. Actual valve weight can vary for valve block configurations. Never attempt to lift valve by hand. Do not lift from handwheel or handwheel adapter. Valve should be lifted from valve body or end flange outlets, ‘Cameron manufactures a variety of valve models with different features and operating requirements. Be certain of valve model and refer to appropriate manual before attempting ‘operation or service on valve. This document is to assist field personnel in operation and maintenance of the FL and FLS handwheel operated gate valve for valve sizes that are listed in this document. Different documents are available for other FL/FLS valve sizes. @ cameron TABLE OF CONTENTS 1.0 20 3.0 40 5.0 6.0 7.0 SCOPE.. GENERAL INFORMATION .. 2.1 Description and Features...... 2.2 Parts List 8 2.3 Dimensional Data 9 VALVE OPERATION.. 3.1 Open Valve ... 3.2 Close Valve PERIODIC MAINTENANCE. 4.1 Valve Body Cavity Lubrication... 4.2 Stem Thrust Bearing Lubrication 4.3 Lubricant Charts..... TROUBLESHOOTING BOLT TORQUE, Recommended Makeup Torques Ft-Ibf... Recommended Makeup Torques Nem ORDERING REPLACEMENT PARTS . re148-2 @ cameron 1.0 SCOPE This manual applies to the following model FL and FLS gate valve sizes and pressure ratings. If size and pressure of particular valve is not listed in this chart, contact Cameron for appropriate maintenance manual for valve. This manual is for This manual is NOT for E i Bore Pressure Rating 113/16 10,000- 20,000 psig __| 41/16 15,000 psig 2416 5000 — 20,000 psig 638 10,000 psig 29/16 5000 - 20,000 psig 5-18 10,000 psig 3-1/8 2000 - 5000 psig 638 10,000 psig 31/16 10,000- 15,000 psig__| 7/16 5000 psig 4108 2000 - 5000 psig ane 10,000 psig 5-1/8 3000 - 5000 psig 6-18 2000 - 5000 psig 6-3/8 2000 - 5000 psig 2.0 GENERAL INFORMATION 2.1 Description and Features The FL or FLS gate valve is a full-bore through-conduit valve designed and manu- factured in accordance with API 6A and NACE MR-01-75. It is available in standard double flange, threaded-end and special block body configurations. The following are standard features of FL and FLS gate valves: 2.1.1 Sealing at gate-to-seat and seat-to-body is metal-to-metal. 2.1.2 Gate and seat assembly has minimum number of parts. One-piece seats and slab gate ensure reliable sealing and simplify field service. The modified ‘Acme gate-to-stem thread allows gate to move back and forth, or float, to seal against seat. 2.1.3 Gate and seat assembly seals in both directions, and gate and seats can be reversed for increased life. 2.1.4 Stem shoulder can be backseated against bonnet to isolate stem seal from valve internal pressure. This feature can be used to prevent leakage to environment in case of stem seal malfunction. Backseating feature can also be used to allow replacement of stem seal while valve is under pressure, a design capability required by API Spec 6A. HOWEVER, replacing stem seal h pressure in valve body is not recommended and should only be done with utmost caution and safety planning. 2.1.5 Non-tising stem prevents cavity pressure increase or displacement of cavity lubricant when valve is stroked open or closed. 2.1.6 All FL and FLS valves have metal-to-metal sealing grease fitting which contains check valve. Stem, gate and seat are lubricated through grease re1482 6 @ cameron fitting which is located on downstream side of stem backseat for safety. No sealant or lubricant ports extend directly into valve cavity. 2.1.7 Valves for 2000 through 5000 psi WP use flat compression-type metal gasket. Seal between valve body and bonnet is a pressure-energized, modified BX- style metal bonnet gasket on 10,000 through 20,000 psi WP valves. 2.1.8 Stem seal is non-elastomeric design resistant to all well fluids. Different ver- sions of these seals are available that can extend temperature rating to cover all API temperature ratings. 2.1.9 An optional add-on torque multiplier is available for larger FL and FLS valves to provide easier operation re148-2 7 @ cameron 2.2 Parts List See valve assembly bill of materials for materials and descriptions of valve compo- nents. 4 Handwheel 2 Grease Fitting 3 Bearing Cap 4 O-Ring 5 Race 6 Bearing 7 O-Ring 8 Stem Adapter 9 Stem Pin @ 10 Packing Gland, © u Stem Seal @ *12___| Backup Ring 13 | Bonnet Nut 14 | Bonnet stud 15 | Bonnet 16 | Grease injection Fitting 17___| Bonnet Gasket 18 [stem 19 | Gate 20 | seat 21___| Seal Ring, 0 22 | Seal Ring, ID (FLS only) 23 [Retainer Plate +24 | Dowel Pin 25 | Body 26 | Name Plate *Not supplied in all sizes and pressures. re148-2 8 @ cameron 2.3 Dimensional Data Table |: Dimensional Data - 2000 psi WP (Dimensions in parenthesis are in millimeters) ‘a. | End-to-End, Flanged riser | a3" | raver | az-ver | 22-18" {Ring Joint) (295.28) | (33.38) | (35878) | (434.97) | (6198) eve" | ze" | 730" | 937 | 1230" Cee re ceo (155.58) | (180.98) | (196.85) | 247.65) |_ (31433) ¢_ [Center of Port to 13" | 33-136" | 16-136" | 176" | 22-34" Top of Stem Adapter 30.20 | @s08q) | (427.04) | casean | (577.85) [Center ofPortto Bottom of Body | ssa” | 6-1 | 7a” | oa | 1342" (Max) (142.86) | (165.10) | (196.85) | (238.13) | (42.90) g_ | Center of Port to 15.37" | 16-10" | 19-116" | 20-4106" | 24° Top of Handwheel Rim 390.53) | (4oasa) | (484.19) | (525.69) | (609.60) 14" 14" 14" va | 18a" F_[Handwheel OD (355.60) | (355.60) | (355.60) | (355.60) | (469.90) Weight (Flanged) ior | 200% | 2401 | 3506 | 800 Ib re148-2 9 @ cameron Table Il: Dimensional Data - 3000 psi WP (Dimensions in parenthesis are in millimeters) ‘a. | End-to-End, tosis" | 12-38" | 135" | _ _ Threaded (269.88) | (314.33) | (346.08) ‘a. End-to-End, 1asia" | 1658" | 17-78" | 20-78" | 24-18" | 24-178" Flanged (Ring Joint) (371.47) | (422.28) | (434.97) | (511.17) | (612.78) | (612.78) aa" | 75" | 7-12" | to1n" | a | 123" B | Extreme Width of Body | (171.45) | (193.67) | (190.50) | (266.70) | (533.40) | (323.85) ¢__ [Center of Port to 13° | 33-1376" | t6-13/16" | 18-7716" | 21sni6" | 22314" Top of Stem Adapter (330.20) | (e58.84) | (427.04) | (477.84) | (541.34 | (577.85) p__ | Center of Port to saan | 61a" | 73a" | oa" | 13-12" | 13-12" Bottom of Body (Max) __| (146.05) | (165.10) | (196.85) | (238.13) | (342.90) | (342.90) g__ [Center of Port to 15-378" | 16-178" | 19-1716" | 20-1116" | 229/16" | 2a Top of Handwheel Rim | (390.53) | (409.58) | (484.19) | (525.45) | (573.09) | (609.60) 14" 14" va” | tata" | 2a" 24" Ft a | enawhesl Ob) (355.60) | (355.60) | (355.60) | (469.90) | (609.60) | (609.60) (Weight (Flanged) 1701 | 2201 | 2601 | 4501 | 7501 | 10001 Table Ill: Dimensional Data - 5000 psi WP (Dimensions parenthesis are millimeters) ia_ [End:to-End, vse | ae | se | _ _ Threaded (269.88) | (314.33) | (346.08) ‘a. | Endto-end, 14s" | 1657" | te5/" | 2157" | 285" | 29" Flanged (Ring Joint) (371.47) | (422.28) | (473.08) | (549.28) | (727.07) |_(736.60) 7 | saner | 9-var [roasne-| ara | 14-18" 8 | Extreme Width of Body | (177.80) | (207.96) | (234.95) | (27464) | (552.45) | (358.78) ¢__ [Center of Port to 15-176" | 15-15/16" | 1613/16" | 17/16" | 215/16" | 22-314" Top of Stem Adapter __| (384.17) | (4oa.ai) | (427.04) | (468.31) | (541.34) | (577.85) p_ [Center of Port to saa | 6 | 7a" | sae | waz | 13-12" Bottom of Body (Max) _| (146.05) | (165.10) | (196.85) | (238.13) | (342.90) | (342.90) [enter of Port to 17-38" | 18-8" | 19-176" | 20-1116" | 23-976" | 24" Top of Handwheel Rim _| (441.33) | (460.38) | (aga.19) | (525.46) | (598.49) | (609.60) 14° var | tet" | rete" | 2a” 2a" F | Handwheel OD (355.60) | (355.60) | (469.90) | (469.90) | (609.60) | (609.60) ‘Weight (Flanged) 17516 | 230% | 360% | 5201 | g001 | 1160Ib reaa2 10 @ cameron Table IV: Dimensional Data - 10,000 psi WP (Dimensions in parenthesis are in millimeters) item Description saaner | zane | 2967 | ane" | ase | 5-18" ‘a. | Endéto-End, Flanged 18-18" | 20-12" | 22-18" | 2438" | 26-38" | 29" (Ring Joint) (463.55) | (520.70) | (565-15) | (619.13) | (669.93) | (736.60) gine | 9-38" | 9-136" | 10-va" | i2-13/16"| 23-12" B [Extreme Width of Body | (230.19) | (238.13) | (249.24) | (260.35) | (225.44) | (596.90) ¢_ | center of Port to 15-18" | 15-8" | 1513/16" | 16-778" | 19-vi6" | 23-78" Stem Adapter (384.17) | (384.17) |_(aoi.64) | (428.63) | (500.06) | (605.43) p | Center of Port to 6-1" | 636" | 7-3" | sz" | 10-3e" | 13-12" Bottom of Body (Max)__| (155.58) | (157.16) | (187.33) | 215.90) | @73.05) | 342.90) ¢ | Center of Port to v3" | 17-3" | 1e-ver | 18-16" | 20-15/16" | 25-18" Top of Handwheel Rim _| (441.33) | (441.33) | (460.38) | (458.79) | (531.81) | (641.35) va | ie-1e" | ie1e" | 24" 24" 28" eae [ences Co (355.60) | (469.90) | (469.90) | (609.60) | (609.60) |_(609.60) Weight (Flanged) 250i | 2751 | 370% | 480% | 8801 | 17501 Table V: Dimensional Data - 15,000 psi WP (Dimensions in parenthesis are in millimeters) item Description PCa ene ee en : 18° 19" 2 | 23-916" 58 |e eeenoaene as7.20)_ | (482.60)_| (533.40) _| (598.49) 978" | 9-7" | 11-42" | 13-916" B | Extreme Width of Body (250.83) | (250.83) _| (292.10) | (344.49) 15-18" | 15-ve" | 17-316" | 205/16" C_| center of Portto Top of stem Adapter | ea, | Gaa’e | tase) | Sue 67" | 6-12" | 8a" | 10-12" D__[center of Portto Bowomof Body(MeX) | (r7a63) | (165.10) | (215.80) | (266.70) 17318" | 17-38" | 19-9/16" | 22-316" rt~—“—~™~™—™———~—~—™r”=~C~—~—C“EE' |= C=C rei" | isa" | 1842" | 24" F | Handwheel OD (469.90) | (469.90) | (469.90) | (609.60) Weight 275b | 300 | 560» | 9901b Table Vi: Dimensional Data - 20,000 psi WP (Dimensions in parenthesis are in millimeters) tem pees Perro eC er 2" 23° 26-12" A _| End-to-End, Flanged (Ring Joint) stnany | (san20) | eas) 778" | aia" | ase" D_|[esisrotithneis) 200.02) | _@98.a5s)_|_ (71.47) 16378" 7 20-38" a rrr—“—“*#RR SCCCll™rmrhlUhUe eam" | 73" | tine © | center of Port to Bottom of Body (Maw) | F955 | clones) | parse) rea | isa" | 21-578" € [center of Port to Top of HandwheelRim | 83", | 1838 | ZnSe re" | 1842" 24" gee | enone Oo (469.90) | (469.90) | (609.60) Weight 5801b | 7601 | 1235 Ib re148-2 @ cameron 3.0 VALVE OPERATION Be aware of surrounding environment and valve condition when operating valve. Be certain of gate position (open/close) before operating valve. Be aware that unexpected circumstances may arise when operating or servicing valve. Review completed JHA and perform Step Back 5X5 to prepare for unplanned situations. ‘Always use the provided handwheel and stand on stable platform when operating valve. Refer to| Tables I through VI for appropriate handwheel size. DO NOT apply more torque than specified values. Do not use cheater pipe or wrench on handwheel to operate. Excessive torque can damage stem pin or other valve parts. If valve handwheel will not rotate, it is possible that rotation is in wrong direction. if there is un- certainty about valve position, open or close, rotate handwheel in both directions before increas- ing torque. Consider possibility of hydrates (ice) in valve if itis still inoperable. When pressure is bled from valve bore, there may be trapped pressure in cavity when valve is either open or closed position. Valve should be cycled to relieve pressure. 3.1 Open Valve Valve is opened by turning handwheel counterclockwise (to left) until it stops, then turning handwheel back to right 1/4 to 1/2 turn to relieve stress on operating mechanism. 3.2 Close Valve Valve is closed by turning handwheel clockwise (to right) until it stops, and then backing off 1/4 to 1/2 turn to allow gate to float and seal. NOTICE Gate must be positioned either “full-open” or “full- closed”. Leaving valve in partially open position can cause throttling and damage to valve components. Number of turns should always be counted to verify, final gate position. Refer to Table VI! for number of turns to open and close valve, appropriate valve size and pressure. re148-2 2 @ cameron Table Vil: Operating Requirements Een 1 Pen [216+] 216°] sve Jeans] 5-16" | 6a [216°] 26°] 3-ve Jere | sve | 6-30" | 10,000 psi WP Peek Jains-2one[sine-] aver rrsneainer|osne-] sane ‘Maximum Opening Torque, Severe Serv Tc148-2 B @ cameron 0 PERIODIC MAINTENANCE DANGER: Lubricating valve involves injection into valve body. This can present a hazard While well is flowing or under pressure. Be aware of unexpected circumstances during or after lubricating valve. Review completed JHA and perform Step Back 5x5 to prepare for unplanned situations. Isolate valve pressure source and release valve pressure before lubricating valve whenever possible. if valve is lubricated under pressure, second check valve or needle valve should be manifolded onto grease fitting as second barrier. This can isolate pressure if grease fitting check fails. Reference facility's work instruction on grease gun safety in order to verify condition of greasing equipment before performing the work Besides wearing appropriate PPE, be sure to read and understand Material Safety Data Sheet (MSDS) of grease or any other chemicals being used on the job to ensure adequate control mea- sures are in place. Be aware of trapped pressure and physical and chemical properties of well fluid. Stroke valve to verify release of any trapped pressure. Use proper unseating tool to check any residual trapped pressure through grease fitting. When removing fitting cap be certain fitting does not rotate with cap. If constant pressure re- lease is heard when loosening cap, retighten cap and plan to replace fitting. During lubrication or other maintenance operations, do not place any part of one’s body in front of fitting, especially when removing fitting or fitting cap. Standard FL and FLS gate valves do not have buried check valves like earlier designs. However, some special customer designs and older valve models such as F and FC may have a buried check valve with word “CHECK” stamped next to grease fitting, During lubrication, do not exceed rated working pressure of valve. Slowdown in pumping speed shows resistance and can be indication that valve cavity is full 4.1 Valve Body Cavity Lubrication NOTICE Proper lubrication will improve performance and life of valve. It is recommended to lubricate valve cavity after ten operating cycles. One cycle equals opening and closing valve one time. Service interval can vary according to application, fluids used and well conditions. 1f pressure is equalized across valve before it is opened, service interval can be extended. If valve is removed from service, body cavity should be lubricated before it is returned to service or put in storage. If it becomes necessary to cement, acidize, frac through, or subject valve to any other unusual service, it is re148-2 14 @ cameron recommended to lubricate valve body cavity before operation. After operation, flush valve with appropriate cleaning/neutralizing fluid. Then operate valve with fresh water or appropriate neutralizing fluid in the line. Finally, lubricate valve body cavity again. Cycling valve during flushing and lubrication will greatly improve effectiveness of maintenance. Lubricant selection chart, Table IX, recommends proper grease for different valve service conditions. Table Vill shows amount of grease required for different FL and FLS valves. For well flow stimulation operations (i.e. fracturing operations) it is recommended to use Diese Resistant grease (PIN 713837-10) to lubricate valve body. Lubrication of valve cavity is performed through grease fitting as follows: 4.1.1 Isolate valve from flow line pressure; stroke valve to open position. 4.1.2 Remove grease fitting cap from grease fitting located on bonnet OD. When removing grease fitting cap, be certain fitting does not rotate with cap. Do not place any part of one’s body in front of fitting vent. 4.1.3 Connect grease gun coupler to grease fitting. 4.1.4 Pump appropriate amount and type of lubricant into body cavity. Refer to Tables VIII and IX. 4.1.5 When valve cavity has been filled, remove grease gun and reinstall grease fitting cap. Torque to 50-60 ft-lb (70-85 Nem). 4.2 Stem Thrust Bearing Lubrication Lubricate thrust bearings as often as required to ensure smooth valve operation. Depending upon ambient temperature, use either standard or low-temperature grease listed in Table IX to lubricate thrust bearings. Do not use diesel resistant or high-temperature grease to lubricate thrust bearings. 4.2.1 Connect handheld grease gun to zert fitting on bearing cap. 4.2.2 Pump lubricant into fitting until clean grease appers at vent hole in bearing cap. re148-2 15 @ cameron 4.3 Lubricant Charts Table Vill: Grease Volume Requirements ees ra Peery DC] ee ena} 1-13/16" All 15 2-116" All 15 2-9/16" To 10,000 80 3.0 29/6" 415,000 90 35. 318" To 5000 110 45 31/16" 10,000 110 45 3-1/16", 15,000. 150 6.0 a8" To 5000 250 10.0 416" 10,000 250 10.0 5-1/8" 5000 310 12.5 6-1/8" To 5000 580 23.0 6-3/8" To 5000 580 23.0 Table IX: Lubricant Selection rua ae} ey aie aa ase BCU Ee kee aed 8 gq) 3 Ale sl els|s| 2 4 a 8 g stonaara | 27507 [| Le | » | room | reossr | rosser | 00800 | ro0570 ve LekEREL [or Lo |e | veor2s | rere | rensra | ross | r08re Teme | wrroasore |g Te |e |» | risoar | rusoars | rrv02r2 | riso2ra | r110274 rel | cameteeet |e |e [| o | amar | rasazs | rene | rear | rane won LOEB | 6 |e Le |» | ror | rosie | seosen | senses | rns nd c | P| | P| zio194 | 701941 | 7101942 | 7101943 | 7101984 een re148-2 16 @ cameron EA OLY 1H Seley Bio! er er Fluid leaks past gate and seat as- | 1. Handwheel is not backed off. | 1. Back off handwheel 1/4 sembly. turn, (See 3.2) 2. Gate or seats are worn. 2. Replace gate or seats. (A,8) Fluid leaks around valve stem. _| 1. Stem seal is worn. 1. Replace stem seal. (A,B) Fluid leaks at bonnet flange. 1, Bonnet seal ring is worn. 1, Replace bonnet seal ring. (AB) 2. Bonnet or body ring groove is _| 2. Return valve to Cameron damaged. for repair. Fluid leaks from bonnet grease _| 1. Check valve inside grease 1. Replace grease fitting. (A,8) fitting. fitting is worn, 2. Leaking by thread. 2. Tighten fitting. (4.8) Handwheel is hard to turn. 1. Thrust bearings have lost 1. Lubricate thrust bearings. lubricant. (See 4.2) 2. Thrust bearings are corroded. | 2. Replace thrust bearings. (AB) 3. Gate and stem threads have _| 3. Lubricate gate and stem lost lubricant. through bonnet grease fitting. (See 4.1) Handwheel turns without open- | 1. Stem pin is sheared, 1, Replace stem pin. (A,B) ing or closing valve. A. These actions are recommended for Cameron personnel or facilities only. B. Refer to FL and FLS Gate Valve Repair Manual. re148-2 7 @ cameron 0 BOLT TORQUE Recommended Makeup Torques Ft-lbf Per API 6A: preload = 50Sy or (ete) eke ea 500-13 27 45 35 59 625-11 52 88. 68 115 750-10 90 153 8 200 875.9 143 243, 188 319 1.00-8 213 361 279 474 1.125-8, 305, 523, 401 686 1.250-8 421 726 553, 953 1375-8 563 976 739 1280 1.500-8 733 1280 962 1680 1.625-8 934 1640 1230 2150. 1.750-8 1170 2050 1530 2700 1875-8 1440 2540 1890 3330 2.000-8 1750 3090 2300 4060 2.250-8 2500 4440. 3280 5820 2.500-8 3430 6120 4500 8030 2.625-8 3970 7100 4720 8430 2.7508 4570 8180 5420 9700 3.000-8 5930 10700 7050 12700 3.2508 7550 13600 8970 16100 3500-8 9430 17000 11200 20200 3.7508 11600 21000 13800 24900 3.875-8 12800 23200 15200 27500 4,000-8 14100 25500 16700 30300 The information in this table is based on API-6A‘s rec- ‘ommended torques for given bolt size. Information is presented for convenience of user and is based on assumptions of certain coefficients of friction (cf). Coeffi- cients of friction are based on approximations of fric- tion between studs and nuts, as well as nuts and flange face. Coefficient friction of 0.13 assumes threads and nut bearing surfaces are bare metal and are well lubricated with thread compound. Coefficient of friction of 0.07 assumes thread and nuts are coated with fluoropolymer material. yc148-2 18 @ cameron Recommended Makeup Torques Nem Per API 6A: preload Meco) 500-13 36 61 48 80 625-11 70 118 92. 155 750-10 122 206 160 270 875-9 193 328 253, 429 1.00-8 288 488 376 639 1.125-8 413 706 540 925 1.250-8 569) 981 745, 1290 1375-8 761 1320 996 1730 1.500-8 991 1730 1300 2270 1.625-8, 1260) 2210 1660 2910 1.750-8 1580 2780 2080 3650 1875-8 1950 3440 2560 4500 2.000-8 2370 4190 3100 5500 2.250-8 3380 6000 4aag 7880 2500-8 4640 8290 6100 10900 2.6258 5380 9620 6390 11500 2.7508 6190 11100 7350 13200 3,000-8 8050 14400 19560 17200 3.250-8 10200 18400 12200 21900 3.500-8 12800 23000 15200 27400 3.7508 15700 28400 18700 33800 3875-8 17400 31400 20600 37300 4.000-8 19100 34600 22700 41000 NOTICE The information in this table is based on API-6A’s rec- ‘ommended torques for given bolt size. Information is presented for convenience of user and is based on assumptions of certain coefficients of friction (cf). Coeffi- cients of friction are based on approximations of fric- tion between studs and nuts, as well as nuts and flange face. Coefficient friction of 0.13 assumes threads and nut bearing surfaces are bare metal and are well lubricated with thread compound. Coefficient of friction of 0.07 assumes thread and nuts are coated with fluoropolymer material re148-2 19 @ cameron 7.0 ORDERING REPLACEMENT PARTS The only information needed for ordering replacement parts for a Cameron gate valve is original valve assembly part number and description of part. Valve assembly part number is stamped on valve body nameplate. It is recommended that description of valve assembly (size, pressure, trim) be included as a check on assembly number, but is not necessary if assembly number is clearly readable. It is not recommended to order replacement parts by using part number off old part or by referring to file copy of valve assembly bill of material. If an engineering change has been implemented to valve assembly to replace one component part number with an- other, the only way to ensure getting updated component is to reference valve assem- bly number and part by description (gate, seat, stem, etc. Part descriptions are shown in arts list, Part .D.). Cameron personnel can then check latest revision of assembly bill of material to obtain appropriate and current replacement part number. Contact Cameron representative for replacement parts for FLS and all other FL gate valves. re148-2 20

You might also like