You are on page 1of 2

Maintenance Checks to Carry Out

A B
B B1
A 1
2

C 4
X B1: Guiding Adjustment [34764; 01.06.2011]
3 HQ A (mm)
0 ... 60  10
5 60 ... 100  10
100 ... 250  10
Step Duct Cleaning Task Description
D 5 E BA Loosen guideway latch screw and rotate the
4
latch away from the cut-out in the duct
BB Slide the duct out of the AC GSI unit.
3
BC Open the duct base and cover, take a dry cloth
and clean the duct and the base. Measure the
1 thickness of the duct at point X. If this distance
A: Cleaning of Magnetic Band [34754; 11.05.2011] is less than 2 mm, replace the duct - ID No.
59311704.
BD  Check the position distance of the tape as
Function and Cleaning Maintenance Checks shown in B1, this is to make sure the
A Starting at the top of the hoistway, clean the magnetic part of the tape does not rub on the
magnetic tape all way down hoistway with a duct when the lift car is running.
clean dry cloth.
 If distance A is more than 10 mm outside the
B: Introduction of Magnetic Band [34759; 01.06.2011] recommended distance, adjust the position of
the AC GSI on the mounting plate to suit.
Place the duct around the magnetic tape and
1 Guideway latch with screw
slide back into position.
2 Guideway duct
3 Duct base BE When the cut-out on the duct is level with
4 Duct cover guideway latch, rotate the latch to lock the duct
5 Magnetic tape in place. Tighten the latch screw. Ensure the
magnetic tape moves freely inside the duct.

Exclusively for competent professionals. Current version of the safety manual and
any local safety requirements must be consulted and followed before initiating works.
AC GSI (SALSIS) KA 107489 EIM
Copyright © 2012 INVENTIO AG All rights reserved. INVENTIO AG, Seestrasse 55, CH-6052 Hergiswil, owns and retains all copyrights and other intellectual
02.06.2012 A4
property rights in this manual. It shall only be used by SCHINDLER personnel or authorized SCHINDLER agents for purposes which are in the interest of
SCHINDLER. Any reproduction, translation, copying or storing in data processing units in any form or by any means without prior permission of INVENTIO AG is
regarded as infringement and will be prosecuted.
Copyright © 2012 INVENTIO AG K 43401963 02 1/2
6 7 8 9 10 11

C D
4

A
B
=
= =

=
5
D: LED Indication [34779; 03.09.2010]
4 3
1 Tension weight 6 Error (ON while in emergency mode)
2 Weight fixation 7 LUET (ON when car in door zone)
3 Magnetic tape 8 UET (ON when contact is closed)
4 Tape contact activation 9 ETSL (ON when contact is open)
plate 10 KNE (ON when contact is open)
5 Contact KSSSI 11 Power (ON when 24 VDC is present)

Indicates the LED can be ON or OFF (see below)

2 2
Fault Rectification
1
LED Indication Description
AC GSI operating normally.
1

Power to AC GSI (SALSIS) is lost and no battery power is


C: Tape Checking [34772; 31.05.2011] present. Check main supply circuit breakers, check battery in
controller.
AC GSI (SALSIS) has detected an overtravel and opened the
Visual, Function and Adjustment Maintenance Checks KNE safety relay, or unit has not been commissioned. Check lift
Check the tension weight (1) is at least 200 mm from the pit floor. position, check unit.
Check the weight fixations (2) are tight and not loose. AC GSI (SALSIS) has detected overspeed condition and
 Check for damage to the magnetic tape (3). opened the ETSL safety relay.
 Check the tape distance to the guide rail at the top and bottom of the 1) Car exceeded 1 m/s in Teach In mode. Check speed setting.
hoistway is equal. 2) Car approached top or bottom floor too fast and safety relay
ETSL opened. Check rated speed setting.
C Check the tape contact activation plate (4) moves freely up and down, with
AC GSI (SALSIS) is in emergency mode due to an error. All
equal distance to the contact KSSSI (5). safety contacts are opened, possible causes/actions are:
 Activate the contact KSSSI (5) by lifting up the tape to simulate the tape 1) Magnetic band broken, damaged or worn
being caught on something in the hoistway, make sure the contact 2) Unintentional car movement detected
activates. Also make sure the switch and the activation plate are aligned to 3) Reset AC GSI (SALSIS) by power off and on again
enable activation in both directions. 4) AC GSI (SALSIS) faulty, replace unit

AC GSI (SALSIS) K 43401963 02 Copyright © 2012 INVENTIO AG 2/2