Spectrophotometer (UV-VIS optional) configuration : Double Beam Optical System Is Ratio Beam System. * Wave Length Range : varies (preferred that started from not less 200nm and not more 1100nm). Spectral Band Width : ≤3nm. Display : LCD or better. Wave Length Accuracy : ±1nm or better. Light Source : Halogen (Vis), deuterium (UV). Absorbance: 0 -1,999A Photometric Modes: ABS, T% & Cons. Stability = 0.001 ABS / Hour. PHOTODETECTOR : Solid state Detector Preferred DATA PROCESSING : LIS Interface preferred PRINTER : required built in printer Supplied With Spare Lamps For Each Unit. Supplied With Complete Accessories. Standard: Mains power 220- 240V ±6% , 50 Hz Service manual Operation manual Service/ maintenance and technical documents inclusive of schematics, component diagrams, trouble shooting and voltage/ wave form checks, diagnostics/ error codes and their interpretations, spare parts ordering information etc. Recommended spare parts list with prices & validity must be provided with the offer Installation & Commissioning : 2 Years comprehensive warranty, from the date of installation and commissioning User / Nurses training, by Specialist from the Suplier. Shall comply to CE marked or FDA Certificate . 150 Lab-2 Hemoglobin Meter. Measuring method : By Cyanmethemoglobin Measuring range: 0 -30 g/dl Three digits indication Dilution ratio: 1:250 Wave lengh : 530 nm Accuracy : 1% Supplied with spare bulb and all accessories 150 Lab-3 PH Meter. Measuring range: pH: 0.00 - 14.00pH MV: -1,999 ~ +1,999mV Temperature: 0 - 100.0°C Resolution: pH: 0.0lpH, mV: ImV, temperature: 0.1 °C Accuracy: pH: ± 0.0lpH, MV: ±0.1% FS Temperature: ±0.5°C± 1 digit Temperature of the measured solution: 0 - 60°C Range of automatic temperature compensation: 0 - 100°C 150 Lab-4 Bilirubin Meter. Measure Total Bilirubin Value. Digital Display. For Management Of Hyperbilirubinemia. High Stability & Accuracy. Supplied With Complete Accessories. 60 Lab-5 A- Laboratory Microscope, Binocular Standard Laboratory Use Type. With Binocular Observation Tube, Mechanical Stage, Condenser And Filter Holder. 10X, 20X, 40X & 100/Oil Achromatic Eyepieces. 6V, 20W Halogen Bulb Illumination System. Supplied With Two Spare Bulbs For Each Unit. Supplied With Complete Accessories. Ground glass filter Spare fuses Main cable One spare lamp Bottle of Immersion oil Dust cover Instruction manual in English Power supply 220-240 V 50Hz 80 Lab-6 Water Bath Capacity About 14 liters Temperature Accuracy = 0.5c. Temperature = Up To75c. Stainless Steel Made , Electronic control. Supplied With Spare Heater For Each Unit. Supplied With Complete Accessories. 20 Lab-7 Blood Bank Refrigerator Temperature = + 3c 1c. Doors: Thermal or Multipane Glass Storage Capacity : 80 Bags (200ml) Minimum. Microprocessor Temperature Control. Complete Alarm System (Temp. low/high, power failure, unit with audiable alarms). Chart Recorder Time is required Recording thermometer, 7 days, electronic Supplied With Complete Accessories. Main UPS for system Operations 100-220V Operation Manual Service Manual NOTE All equipment needing consumables must allow the possibility to use generic and/or locally made consumables and/or disposables. Compliance to this condition must be declared here by the bidders. Service/ maintenance and technical documents inclusive of schematics, component diagrams, trouble shooting , spare parts ordering information etc. 2 Years comprehensive warranty, from the date of installation and commissioning & Compressor 5 years Warranty Installation & Commissioning must be done by manufacturer engineer The system offered shall be designed to operate normally under the conditions of the purchaser's country. The conditions include Power Supply, Climate, Temperature, Humidity, etc. Users training, by Specialist from the Supplier. Shall comply to CE marked or FDA Certificate 80 Lab-8 Bench Top Centrifuge Table Top Centrifuge. Maximum Revolution = 5,500 RPM. Full Automatic Microprocessor Control. Timer = From 0 - 60 Minute With Hold Mode . Capacity = 15ml x 16 Tubes. Supplied With Complete Accessories. Supplied With One Year Recommended Spare Parts. 1 Year comprehensive warranty, from the date of installation and commissioning User / Nurses training, by Specialist from the Suplier. Shall comply to CE marked or FDA Certificate 40 Lab-9 Hematocrit Centrifuge Micro Capillary Hematocrit Centrifuge. Revolution = 12,000 - 14,000 RPM. Digital Speed Display Indicator. Capacity = 20 CapillaryTubes. Supplied With Complete Accessories. Supplied With One Year Recommended Spare Parts. 1 Year comprehensive warranty, from the date of installation and commissioning User / Nurses training, by Specialist from the Suplier. Shall comply to CE marked or FDA Certificate Lab- 40 10 Differential Counter Digital Light Weight, Count with Totalizer. For simplifying differential blood cell counts. This counter eliminates the calculations necessary when making Leukocyte counts. The eight keys represent the eight normal Schilling groups of Leucocytes, i.e.: Basso, Eos Lab- 40 11 Water Distiller Automatic Microprocessor Control. (Optional) Capacity = 2- 5 Liter / Hour . Water purification system included. low water cut off Water supply flow rate liters/hr 60lit approx. Supplied With Complete Accessories & conection. Lab- 40 12 Timer, Interval Timing 60 Minutes. Three separate recording /display fields which can be used independent-three timers in one. Stopwatch, timer and clock function available on all three fields. Magnetic clip aids convenient handling, each uses a 24 h system displaying hours, minutes and sec. Lab- 40 13 Laboratory Stool Swivel Chrome-plated tubular framed stool with adjustable height Wooden seat Adjustable backrest, hand-controlled and foot circular rest Shall be mobile on 5 stars stand, 5 castors Lab- 40 14 a-Laboratory Medical Refrigerator Maintains internal air temperature between +2°C and +8°C Smooth, molded steel cabinet with rust-proof enamelled finish and bevelled edges Easy non-electric push-button lighting. Shall have no corners to trap dirt and bacteria. The absorption-type cooling system shall be quiet and dependable, with no compressor or other moving parts to wear out Audio/visual alarm signal on temperature deviation, with remote alarm terminals providing mains failure alarm signal Shall be easy-to-clean and all-white interior features adjustable, removable shelves and door bins for stocking flexibility Internal capacity shall be minimum 250 lit. Lockable door, 2 keys for security Main power supply 100-240V Supplied with : 5 removable shelves Operation Manual Service Manual NOTE All equipment needing consumables must allow the possibility to use generic and/or locally made consumables and/or disposables. Compliance to this condition must be declared here by the bidders. Service/ maintenance and technical documents inclusive of schematics, component diagrams, trouble shooting , spare parts ordering information etc. 2 Years comprehensive warranty, from the date of installation and commissioning Installation & Commissioning must be done by manufacturer engineer Users training, by Specialist from the Suplier. The system offered shall be designed to operate normally under the conditions of the purchaser's country. The conditions include Power Supply, Climate, Temperature, Humidity, etc. Lab- 100 15 Automated Micropipette, Fixed type (Different sizes) 1- 20 µl 2- 50 µl 3- 100 µl 4- 1000 µl Lab- 100 16 Automated Micropipette, Variable type (Different Sizes) Large, clear digital display, compatible with wide range of tips. High degree of accuracy and precision, easy maintenance and calibration. 1-Single Variable: a- 100 – 1000 µl b- 20 – 200 µl c- 10 – 50 µl d- 2 - 20 µl Lab- 40 18 Analytical Balance Has rapid tarring over full 160 gm weighing range. Digital read out to 0.01mg precision standard deviation 0.01mg complete with cord plus dust cover, cleaning brush and instruction manual. Accessories: light bulbs for one-year supply. With anti-vibration mat. Lab- 40 19 Differential Counter manual For simplifying differential blood cell counts, eliminates the calculations necessary when making Leukocyte counts. The eight keys represent the eight normal Schilling groups of Leucocytes, i.e.: Basso, Eosin, Myelo, Juven, stab seg, Lymph, Mono. Above each key is the name and picture of particular cell. When a total of one hungered cells is counted, a bell rings. The percentage of each type of cell is then read directly from the window above each key. Counter clockwise rotate handle Lab- 40 20 Stop Watch (Digital) Lab- 20 21 Elisa Machine Open system Elisa Reader: * Two basic readers for 96-well micro plates, Flexibility and reliability, Fast reading: 5s for 96well plates, Internal memory holds up to 64 assay, Data manipulation through software, Spectral range: 340-750 nm, Read-out range: 0-3.5 Abs, Measurement range: 0-2.5 at 405 nm, Reading speed: 5 s entire plate, Shaking: Linear shaking , 3 speed . Photometric Method, Optical System: measurement and reference Channels, multiple channels required, Measurement modes: Single/dual wavelength, endpoint, Singe wavelength kinetic and two point. Calculation modes: Ranged Grayscale Threshold, Floating cut-off, Point-to-point, Linear regression and Cubic spline Reading speed: 5 entire plate, linearity: {( -2 )–(+2) }% Abs. CV<0.2%. Resolution, OD: 0,01, Compatible Microplates: roun/flat bottom preferred, programmable Assays is preferred. with Display, interface. Supply with: all required accessories to put Machine in function, Cover, Adapter, fuse, bulbs and calibration Plate. Elisa Washer: Automated, Compatible plates: 96-well plates, Reliable and easy to use, Co-axial wash heads for trouble-free washing and low residual volumes 8 and 12 way interchangeable wash heads, In-line rinse capability automatic pump shutdown. Wash/waste bottle capacity: 2 L+ 2 L. Additional wash bottle capacity: 2 L. Priming consumption: 15-20 ml. Wash heads: 8-and 12 ways. Program cards: 1-4 washes. Accuracy: ˃2%, Max dispense volume (ml/well): ˂1 Power Supply / Input Power: 220 / 50 Hz Bukup suitable UPS Supplied with : Operation Manual Service Manual Shall comply with CE marked or FDA Certificate. Service/ maintenance and technical documents inclusive of schematics, component diagrams, trouble shooting , spare parts ordering information etc. 2 Years comprehensive warranty, from the date of installation and commissioning Installation & Commissioning must be done by manufacturer engineer Users training, by Specialist from the Suplier. The system offered shall be designed to operate normally under the conditions of the purchaser's country. The conditions include Power Supply, Climate, Temperature, Humidity, etc. Lab- 20 22 Automatic hematology Analyzer (cbc) complete blood counter Principle: Electrical Impedance Method- WBC / RBC / PLT, Colorimetric- HGB Open or Closed System, Diluent and reagents (3 or 5) , device must have an economic consumption of reagents mechanism. Reportable Parameters: 3 Part Differential, 23 Parameters - WBC, LYM#, MID#, GRA#, LYM MID%,GRA%, RBC,HGB, HCT,MCV, MCH, MCHC, RDW-SD, RDW-CV, PL MPV, PDW, PCT,P- LCR, WBC Histogram, RBC Histogram, PLT HistogramT Operating Platform : Windows interface with mouse control (Not Compulsory). Speed : 40-60 samples per hour Calibration : Both Automatic and Manual Calibration mode. 3 sets of Calibration co -efficient for Whole Blood, Anti-coagulant Peripheral Blood and Pre-diluted Peripheral Blood. Quality Control : 3 QC Method; and X-R QC with appropriate QC Charts, Westgard Results: Internal memory can store at liest 40,000 Test values with Histograms Printer / Display: Builtin thermal printer with optional external printer, Color LCD, 9" Interface: 2- 4 USB, 1 RS232 serial port, 1 Lan, 1 PS2 Mouse, 1 PS2 Power Supply / Input Power: 220 / 50 Hz Backup suitable UPS Supplied with : Operation Manual Service Manual Service/ maintenance and technical documents inclusive of schematics, component diagrams, trouble shooting , spare parts ordering information etc. 2 Years comprehensive warranty, from the date of installation and commissioning Installation & Commissioning must be done by manufacturer engineer Users training, by Specialist from the Suplier. Shall comply with CE marked or FDA Certificate. NOTE Machine with close Or open system, the supplier must supply free quantity of reagents with machine and must mention how many free kits and tests of reagents would be supplied. The cost of soluations & consumbles per Test for one Year should also be offered. Machine with close Or open system, should be put cost of soluations, consumbles per Test ,,should be put cost of reagents kits for at least 5 years (price / kit ) and how many tests per kit. Device must be supplied with manufacturer reference test sample for calibration and quality assurance. Depended of above we well choise the system The system offered shall be designed to operate normally under the conditions of the purchaser's country. The conditions include Power Supply, Climate, Temperature, Humidity, etc. Lab- 20 23 Semi-Automated biochemistry Analyzer CONFIGURATION Benchtop Connection to LAS track Processing modes System capacity THROUGHPUT, max tests 50-70 /hr SAMPLE TYPE Serum/plasma Urine CSF SAMPLE SIZE, 2- 30 µL TEST MENU, min Acid phosphatase ,Alanine transaminase (ALT) ,Albumin ,Aldolase,Alkaline phosphatase (ALP) ,Amylase ,Aspartate transaminase (AST) ,Bilirubin (direct/total) ,Blood urea nitrogen (BUN) ,C3 ,C4 ,Calcium ,Chloride ,Cholesterol ,Cholinesterase ,Creatine kinase (CK) ,Creatinine ,CK-MB ,CO2 ,CSF protein ,GGT ,Glucose ,IgA ,IgG ,IgM ,Inorganic phosphorus ,Iron ,Lactate dehydrogenase (LDH) ,Magnesium ,P-5-P ,Potassium Total protein Sodium Thyroxine (T4) Tyroxine uptake (TU) Triglycerides Urea Uric acid Urine protein Others HBDH, lipase, neonatal bilirubin, RF, LD-1, ammonia, TIBC, LDL etc according to the device range of tests offered. PROGRAMMED 50 TESTS USER-DEFINABLE TESTS METHOD USED End point, rate, ISE OR Kinetic Optical system (Photometric ) Light source (Tungsten-halogen ) REAGENTS, TYPE Liquid Substitution Refrigerated onboard SYSTEM FEATURES Closed-tube sampling Direct sampling Liquid-level sensing Clot detection Auto dilution Abnormal values flag Auto verification Auto quality control Auto calibration DATA MANAGEMENT Display LCD Results stored Computer interface Current LIS vendor interfaces Printer Bar-code reader LINE POWER, 220 VAC, 50Hz Backup WATER REQUIREMENTS, <15 L/hr Onboard supply Supplied with: Set of 3 sterilisation containers adapted to the equipment proposed Water distiller device Operation Manual Service Manual Shall comply with CE marked or FDA Certificate. NOTE All equipment needing consumables must allow the possibility to use generic and/or locally made consumables and/or disposables. Compliance to this condition must be declared here by the bidders. Service/ maintenance and technical documents inclusive of schematics, component diagrams, trouble shooting , spare parts ordering information etc. 2 Years comprehensive warranty, from the date of installation and commissioning Installation & Commissioning must be done by manufacturer engineer Users training, by Specialist from the Suplier. The system offered shall be designed to operate normally under the conditions of the purchaser's country. The conditions include Power Supply, Climate, Temperature, Humidity, etc. Lab- 20 26 Blood bags Shaker Microplate shaker provides reliable, regulated shaking for two or four microplates with a speed range of 150 to 1000rpm. Variable speed, horizontal microtitre plate shaker Variable speed: 150 to 1000rpm or more Orbit: 2mm Integral timer, 1 minute to 24 hours, with automatic switch-off Standard platform for two microplates, optional accessory platform for four microplates Low voltage power supply enables safe coldroom operation Operating ambient temperature range 4°C to 45°C, for use in coldroom or incubator Low energy consumption. The Specification attached with catalogue Lab- 40 27 Flame Photometer Digital, including integral dilutor, automatic digital readout, rapid measurement of Na, K and Li on a minimum sample of approx1.6ml Complete with standard reagents, solutions, Integral diluter, air compressor, hoses valve for gas cylinder Lab- 100 28 Rack Test tubes. Stainless Steel . 12 holes 13 mm 3 Tier 12 holes 20 mm 3 Tier Lab- 20 29 Donor Chair High Quality, Comfortable with storage drawers WIth adjustable back rest, adjustable dual arm rest nd not more 1100nm).
mponent diagrams, trouble
interpretations, spare c and/or locally made lared here by the bidders. mponent diagrams, trouble
ioning & Compressor 5
ons of the purchaser's
nts. This counter eight keys represent the
ee timers in one. ip aids convenient compressor or other
nals providing mains
shelves and door bins for
c and/or locally made
lared here by the bidders. mponent diagrams, trouble
ons of the purchaser's
of accuracy and precision,
th cord plus dust cover,
essary when making
ps of Leucocytes, i.e.: hen a total of one s then read directly from