46SV2/2AG055T
101682031
Operating data
Pumpe ty pe Single head pump Fluid Water, pure
No. of pumps / Reserv e 1 / 0 Operating temperature t A °C 4
Nominal f low US g.p.m. 200 pH-v alue at t A 7
Nominal head f t 89.99 Density at t A kg/dm³ 1
Static head ft 0 Kin. v iscosity at t A mm²/s 1.569
Inlet pressure bar 0.098 Vapor pressure at t A bar 0.00789
Env ironmental temperature °C 20 Solids 0
Av ailable sy stem NPSH ft 0 Altitude f t 3281
Pump data
Make Lowara Nominal US g.p.m. 203.5 ( 203.5 )
Speed rpm 2900 Flow Max- US g.p.m. 264.2
Number of stages 2 Min- US g.p.m.
Max. casing pressure bar Nominal f t 93.2
Max. working pressure bar 3.9 Head at Qmax f t 45.8
Head H(Q=0) f t 130 at Qmin f t 127.4
Weight kg 104 Shaf t power kW 5 ( 5 )
Max. mm 133 Max. shaf t power kW 5.2
Impeller R designed mm 133 Ef f iciency % 71.91
Min. mm 133 NPSH 3% f t 8.5
Motor data
Manuf acturer Lowara Electric v oltage 220 V Speed 2910 rpm Insulation class 155 (F)
Specif ic design IE3 Three phase surf ace motor (e-SV) Frame size 132R Colour RAL 5010
Ty pe PLM132RB5/355 E3 (220-240/380-415V)
Rated power 5.5 kW Degree of protection IP55
Electric current 18.1 A
Remarks:
Page 1 / 4
Customer Date 5/11/2022
Contact Project
Phone number
Project no.
Tender Hydraulic
Email
46SV2/2AG055T
101682031
Hydraulic data
30
20
10
0
[ft] NPSH-values
24
20
16 46SV2/2A
12
8 8.5 ft
4
[kW] Shaft power P2
6.0
5.5
46SV2/2A (P2)
5.0
4.5 4.98 kW
4.0
3.5
3.0
2.5
2.0 204 US g.p.m.
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220 230 240 250 260 270 280[US g.p.m.]
Customer Date 5/11/2022
Contact Project
Phone number Project no.
Dimensional Data
Email
46SV2/2AG055T
101682031
Drawing
Dimensions m m
D1 214 Weight
D2 300
L1 624 104 kg
L2 375
M 168
46SV2/2AG055T
101682031
Power input P1
Total costs
0.00
EUR
0.00
EUR
Disclaimer: The calculations and the results are based on user input values and general assumptions and provide only estimated