Professional Documents
Culture Documents
Catalog No. 2004: Mitutoyo America Corporation
Catalog No. 2004: Mitutoyo America Corporation
Distributed by:
religion to all, along with the lasting wish for a peaceful world and fulfillment of
Mitutoyo Mexico
Prolongacion Industrial Electrica
No. 15
Col. Parque Industrial
Naucalpan C. P. 53370
Naucalpan de Juarez
Estado de Mexico, Mexico
Phone (525) 312-5612
Fax: (525) 312-3380
Corporate Headquarters
Metrology Centers
Factories/R&D
Calibration Lab
Detroit Regional Office & Aurora Regional Office & Los Angeles Regional Office &
45001 Five Mile Rd. 945 Corporate Blvd. 16925 Gale Ave.
Plymouth, MI 48170 Aurora, IL 60504 City of Industry, CA 91745
Ph: (734) 459-2810 Ph: (630) 978-5385 Ph: (626) 961-9661
Fax: (734) 459-0455 Fax: (630) 978-3501 Fax: (626) 333-8019 Precision is our Profession
Additional: Westford, MA • Huntersville, NC • Indianapolis, IN • Montreal, Quebec
I
INTRO IV-V Amer/Prod (2003) 12/12/03 4:22 PM Page 1
IV
INTRO IV-V Amer/Prod (2003) 12/12/03 4:22 PM Page 2
Repair Department
Our three in-house repair facilities are capable of repairing the full range of Mitutoyo
small tools and maintains an average 5-7 day turn-a-round on all repairs. Repair parts
are kept in stock to ensure timely and quality repair services.
Parts Center
Aurora, Illinois
Our Parts Department stocks over 10,000 individual parts for Mitutoyo products, with
same day and 24 hour shipping available for most. (A Parts CD-Rom is available
through your Mitutoyo distributor.)
Calibration Laboratories
Elk Grove Village, IL
Plymouth, MI
These facilities utilize state-of-the-art technology and are staffed by professional cali-
bration technicians to provide NIST-traceable accuracy certification as well as calibra-
tion/recalibration of Mitutoyo and other manufacturers’ gage blocks and gages.
(A Calibration Lab Price List and Accreditation Scopes are available upon request.)
V
INTRO VI-VII Cert (2003) 12/17/03 10:48 AM Page 1
Internet –
www.mitutoyo.com
Customer Service Support
Contact information
www.mitutoyo.com
Product Sales Information Measurlink Support Services
Ph: (630) 820-9666 x 6313
• Product & Parts Availability Fax:(630) 820-3418
• Pricing www.measurlink.com
• Quotations
Coordinate Measuring Machines
• Demonstrations
CMM Field Ph: (630) 820-9590
Michigan Ph: (734) 459-2810 Service Fax: (630) 820-9110
Fax: (734) 459-0455
CMM Software Ph: (630) 978-6470
Illinois Ph: (630) 978-5385 Support Fax: (731) 822-7400
Fax: (630) 978-3501
CMM Parts Ph: (630) 978-6468
Los Angeles Ph: (626) 961-9661 Fax: (630) 978-6472
Fax: (626) 333-8019
Calibration Services
Canada* Ph: (905) 821-1261
www.mitutoyo.ca Fax: (905) 821-4968 • Certification
CMM Sales Ph: (630) 978-6455 • Gage Blocks
Fax: (630) 978-6475 • Tools & Gages
* Please call Mitutoyo Canada Inc. for any Canadian Illinois Ph: (847) 593-7750
inquiries listed below Fax: (847) 593-7758
Michigan Ph: (734) 455-9330
Advanced Technical Support Services Fax: (734) 455-5970
• Specifications
Repair Services
• Technical Inquiries Illinois Ph: (630) 820-3334
• Application Support Fax: (630) 820-2530
Los Angeles Ph: (626) 961-9661
Fax: (626) 333-8019
Aurora Ph: (630) 978-5385 Education Services
Fax: (630) 978-5397
Indianapolis • Seminars
Boston
Charlotte
} Ph: (630) 978-5385 • Textbooks
Mitutoyo Institute of Metrology Aurora, IL
Los Angeles Ph: (626) 961-9661 Ph: (630) 978-6469
Fax: (626) 333-8019 Fax: (630) 978-6471
Detroit Ph: (734) 459-2810 Marketing Services
Fax: (734) 459-0455
Toronto Ph: (905) 821-1261 Illinois Fax: (630) 978-5394
Fax: (905) 821-4968
Montreal Ph: (514) 337-5994 Instafax
Fax: (514) 337-4498
Technical Support Services Literature Request 1-800-578-9130
Ph: (630) 820-9785
Fax: (630) 820-7413 Web
www.mitutoyo.com
VII
INTRO VIII-IX Inst Maps (2003) 12/15/03 2:30 PM Page 2
detroit
Detroit, Michigan
45001 Five Mile Rd. • Plymouth, MI 48170
Phone: (734) 459-2810 • Fax: (734) 459-0455
los angeles
Los Angeles, California
16925 Gale Ave. • City of Industry • CA 91745
Phone: (626) 961-9661 • Fax: (626) 333-8019
VIII
INTRO VIII-IX Inst Maps (2003) 12/15/03 2:30 PM Page 3
boston
Boston, Massachusetts
1 Park Dr. • Suite 11 • Westford, MA 01886
Phone: (630) 978-5385 (Aurora, IL)
indianapolis
Indianapolis, Indiana
9855 Crosspoint Blvd. • Suite 148 • Indianapolis, IN 46256
Phone: (630) 978-5385 (Aurora, IL)
I-69 North to 96th Street Exit. Turn Left on 96th Street to Hague Rd. Turn Right
on Hague Rd. to Crosspoint Blvd. Turn Right on Crosspoint Blvd. to our location.
charlotte
Charlotte, North Carolina
11515 Vanstory Drive • Suite 150 • Huntersville, NC 28078
Phone: (630) 978-5385 (Aurora, IL)
From Charlotte/Douglass Airport or Downtown Charlotte:
Airport exit to either I-85 or I-77 (north) towards Statesville.
Take exit 23 (Huntersville) off of I-77. Turn west (left) from exit onto Gilead Rd.
Turn south (left) into Huntersville Business Park onto Reese Blvd. Keep right on
Reese Blvd., (at main building) to Reese Blvd. west, turn right on Vanstory Dr.
(third street to the right). Proceed on Vanstory Dr. to far end of the Stewart
Bldg. (on left). Turn left into last driveway. Our office will be located in the end
unit.
canada
Mitutoyo Canada Inc.
www.mitutoyo.ca
2121 Meadowvale Blvd. • Mississauga • Ontario • Canada L5N 5N1
Ph: (905) 821-1261 • Fax: (905) 821-4968
Take Highway 401 West. Exit North on Mississauga Road. Continue North past
Derry Road to Meadowvale Blvd., turn left or West. Mitutoyo Canada is on North
side of street.
Montreal, Quebec
7075 Place Robert-Joncas • Suite 129
Arrond. de Saint-Laurent
Montreal, • Quebec, H4M 2Z2 Canada Precision is our Profession
Ph: (514) 337-5994 • Fax: (514) 337-4498
IX
INTRO X-XI Sugas Book (2003) 12/12/03 2:22 PM Page 1
X
INTRO X-XI Sugas Book (2003) 12/12/03 2:22 PM Page 2
Contents
XI
INTRO XII Traceability (2003) 12/16/03 10:42 AM Page 1
Traceability at Mitutoyo
LENGTH
Definition of the meter Definition
NMI
NIST (USA) NMIJ (Japan)
Realization &
Transfer
Laboratory
Mitutoyo America Laboratory Mitutoyo Factory
On-Site
(if needed)
Mitutoyo America field service
Customer
Mitutoyo products shown in this catalog
Traceability is an essential requirement for all measurements. The requirements for demonstrating traceability vary from
At Mitutoyo, we consider providing traceability to our industry to industry. In the past, some industries required
customers to be a critical part of our business. Traceability NIST test numbers, but that practice is now obsolete and
is often referred to as a “chain of comparisons”, and that has been replaced in many industries by the much more
chain always starts with a precise definition. For length demanding requirement of ISO 17025 accreditation. To meet
measurements, the meter is defined by how far light moves in these needs, Mitutoyo America offers our customers A2LA
a vacuum in a defined amount of time. The job of reducing accredited calibrations either in our labs or at your facility.
that definition into a practical measurement belongs to the None of our competitors can match the range and accuracy
world’s National Metrology Institutes (NMI). The NMI in the of accredited calibration services offered by Mitutoyo. Not
U.S. is the National Institute of Standards and Technology every quality system requires accreditation, and for the less
(NIST), where they realize and transfer the definition of demanding needs, our standard factory issued certificates
length to physical measurements of gage blocks, line can still be used to ensure the required traceability.
scales, and other primary standards. From there, traceable
measurements at other laboratories and factories are Whatever the measurement, whatever the requirements for
possible. Mitutoyo factories and calibration labs regularly traceability, Mitutoyo has the most technically advanced
send their standards to NIST; however, traceability can also metrology products and calibration services to meet your
be established through other recognized NMIs, such as the specific needs
National Metrology Institute of Japan (NMIJ). The world’s
leading NMIs, such as NIST and NMIJ, routinely participate
in intercomparisons to ensure global traceability to the same
unit of length.
XII
INTRO II-III T of C (2003) 12/15/03 2:18 PM Page 2
INTRODUCTION
IFC - XII Contact Information • Metrology Centers • Sales/Product
Support Services • Maps/Directions • Traceability
B 1 - B 18 Form Measuring
(Surface Roughness Instruments)
Form Measuring
C1-C9 (Contour Instruments)
Form Measuring
D 1 - D 10 (Roundness Instruments)
E 1 - E 14 Vision Systems
(Vision Instruments)
F 1 - F 37 Measuring Instruments
(Optical Instruments)
Measuring Instruments
G 1 - G 13 (Laser Scan Micrometers)
Measuring Instruments
H 1 - H 19 (Hardness Testing Instruments)
J 1 - J 11 ISO 9000
Data Management
K 1 - K 19 (Statistical Process Control)
Table of Contents
II
INTRO II-III T of C (2003) 12/15/03 2:19 PM Page 3
Micrometers L 1 - L 64
Micrometer Heads M 1 - M 20
Calipers O 1 - O 39
Height Gages P 1 - P 17
Depth Gages Q 1 - Q 12
Indicators R 1 - R 123
Miscellaneous S 1 - S 40
Gage Blocks T 1 - T 26
Height Masters V 1 - V 11
Alphabetical & Numerical Indexes (Located in the back of this catalog.)
Bright-Strato CNC - 707, 710, 910, 916, 1620, 1630, 1640 A-6
Bright-Strato CNC - 707, 710, 910, 916, 1620, 1630, 1640 A-6
QM-Measure
333/353
Manual CMMs
Features
• A shop floor measuring machine based on a new
concept to facilitate measurement of workpieces
with a complex form.
QM-Measure
• Measuring error is guaranteed to be
A: Fine feeding device
E=(3.0 + 4L1000)µm, equal to that of a CMM. B: Temperature compensation unit
C: Sub-plate
D: Machine stand
• Employing an easy measurement menu that
allows measurement without referring to the basic
coordinates. For measurement procedure, simply
enter values in the order indicated on the screen. QM-Data 300
A-2
A-02 (2003) full size 12/8/03 8:37 AM Page 1
QM-Measure
333/353
Manual CMMs
Features
• A shop floor measuring machine based on a new
concept to facilitate measurement of workpieces
with a complex form.
QM-Measure
• Measuring error is guaranteed to be
A: Fine feeding device
E=(3.0 + 4L1000)µm, equal to that of a CMM. B: Temperature compensation unit
C: Sub-plate
D: Machine stand
• Employing an easy measurement menu that
allows measurement without referring to the basic
coordinates. For measurement procedure, simply
enter values in the order indicated on the screen. QM-Data 300
A-2
A-03 (2003) full size 12/8/03 8:38 AM Page 1
Bright
M500/M700
Manual CMMs
Features
• Lightweight and compact machines with
an excellent cost/performance ratio.
• High measuring accuracy.
• Ultra smooth action on all three axes.
• Direct digital data exchange.
• Self adjusting high rigidity air bearings.
• Constant force spindle grip for maximum
consistency - even when in the hands of
inexperienced operators.
Specifications
Model No. BRT-M507 BRT-M707 BRT-M710
X-axis 20" (500mm) 28" (700mm)
Measuring range Y-axis 28" (700mm) 28" (700mm) 40" (1000mm)
Z-axis 16" (400mm) 24" (600mm)
Resolution .00002" (0.0005mm) .00002" (0.0005mm)
*ISO10360-2 E=4.0+5L/1000µm E=5.0+5L/1000µm
Accuracy
R=5.0µm (As using with TP-2) R=5.0µm (As using with TP-2)
Weight balance Counter balance
Clamp Air clamp
Fine feed All range continuously
Width 42.28" (1074mm) 54.33" (1380mm)
Dimensions Depth 48.74" (1238mm) 53.74" (1365mm) 65.55" (1665mm)
Height 88.11" (2238mm) 107.84" (2739mm)
Machine weight (Inc. Stand) 1195 lbs (542 kg) 2492 lbs (1130 kg) 3263 lbs (1480 kg)
Max. workpiece weight (Kg) 352 lbs (160 kg) 1102 lbs (500 kg) 1763 lbs (800 kg)
Air Pressure 0.4MPa (4kgf/cm2) on 58 psi
Air Consumption
(under normal condition) 40 L/min. on 1.44 CFM
Temperature specification 68°F ± 1.8°F (20°C ± 1°C)
*ISO10360-2: 1994
E: Indication accuracy
R: Probing error
A-3
A-04 (2003) full size 12/15/03 10:25 AM Page 1
Crysta-Apex C Series
CNC Coordinate Measuring Machines
Features
• High accuracy
• High speed
• High acceleration
• Ultra silent motion
• Various choices of probe systems:
Touch signal probe
High speed scanning probe
Vision probe
Screw depth measuring probe For further information request
Laser probe, etc. Bulletin No. 1626
Specifications
Model CRT-Apex C544 CRT-Apex C574 CRT-Apex C776 CRT-Apex C7106 CRT-Apex C9106 CRT-Apex C9166 CRT-Apex C9206
Measuring X Axis 19.88" (505mm) 27.75" (705mm) 35.62" (905mm)
Range Y Axis 15.94" (405mm) 27.75" (705mm) 27.75" (705mm) 39.56" (1005mm) 39.56" (1005mm) 63.19" (1605mm) 78.93" (2005mm)
Z Axis 15.94" (405mm) 23.81" (605mm) 23.81" (605mm)
Resolution .000004" (0.0001mm) .000004" (0.0001mm) .000004" (0.0001mm)
Drive CNC mode Max moving speed Max moving speed Max moving speed
Speed = 430mm/s (16.93"/s) (3D) = 520mm/s (20.47"s) (3D) = 20.47"/s (520 mm/s) (3D)
Max measuring speed = 8 mm/s Max measuring speed = 8 mm/s Max measuring speed = 8 mm/s
Joystick mode Moving speed = 0-80 mm/s Moving speed = 0-80 mm/s Moving speed = 0-80 mm/s
Measuring speed = 0-3 mm/s Measuring speed = 0-3 mm/s Measuring speed = 0-3 mm/s
Max Acceleration 0.17G (3D) 0.23G (3D) 0.23G (3D)
Measuring Material Granite Stone Granite Stone Granite Stone
Table Size 25.12 x 33.86" 25.12 x 45.66" 33.85 x 55.90" 33.85 x 67.71" 41.73 x 67.71" 41.73 x 91.33" 41.73 x 107.08"
(638 x 860mm) (638 x 1160mm) (860 x 1420mm) (860 x 1720mm) (1060 x 1720mm) (1060 x 2320mm) (1060 x 2720mm)
Work Max.height 21.46" (45mm) 31.49" (800mm) 31.49" (800mm)
piece Max. weight 220lbs (100 kg) 396lbs (180kg) 1760lbs (800kg) 2200lbs (1000kg) 2640lbs (1200kg) 3300lbs (1500kg) 3960lbs (1800kg)
Width 42.60" (1082mm) 57.87" (1470mm) 65.74" (1670mm)
Dimensions Depth 43.46" (1104mm) 57.48" (1460mm) 64.96" (1650mm) 76.77" (1950mm) 76.77" (1950mm) 105.90" (2690mm) 121.65" (3090mm)
Height 86.02" (2185mm) 107.48" (2730mm) 107.48" (2730mm)
Machine weight 1133lbs (515kg) 1452lbs (660kg) 3685lbs (1675kg) 4293lbs (1951kg) 4908lbs (2231kg) 6309lbs (2868kg) 8606lbs (3912kg)
Air Consumption 50L/min or 1.8CFM 60L/min or 2.16CFM 60L/min or 2.16CFM
(under nominal condition)
Air Pressure 0.4Mpa (4kgf/cm2) or 58PSI
Range 1 64.4° F - 71.6° F (18° C - 22° C)
Range 2 60.8° F - 78.8° F ( 16° C - 26° C)
Temperature
Variation / hour 3.6° F ( 2.0° C ) / hour
Variation / day Range 1 = 3.6° F ( 2.0° C ) / day Range 2 = 9.0° F ( 5.0° C) / day
Gradient 1.8° F ( 1.0° C ) / m (Vertically) 1.8° F ( 1.0° C) / m (Horizontally)
Crysta-Apex C Crysta-Apex C
Accuracy
544 / 574 / 776 / 7106 9106 / 9166 / 9206
IS010360-2: 2001
MPEE MPEp MPEE MPEp
Temperature 1 TP2 / 20 2.2 + 3L/1000µm 2.2µm 2.2 + 3L/1000µm 2.2µm
64.4° - 71.6° F TP200 1.9 + 3L/1000µm 1.9µm 1.9 + 3L/1000µm 1.9µm
(18° to 22° C) MPP100 / SP600 1.7 + 3L/1000µm 1.7µm 1.7 + 3L/1000µm 1.7µm
Temperature 2 TP2 / 20 2.2 + 4L/1000µm 2.2µm 2.2 + 4L/1000µm 2.2µm
60.8° - 78.8° F TP200 1.9 + 4L/1000µm 1.9µm 1.9 + 4L/1000µm 1.9µm
(16° - 26° C) MPP100 / SP600 1.7 + 4L/1000µm 1.7µm 1.7 + 4L/1000µm 1.7µm
MPEE is the maximum permissible error of indication of a CMM for size measurement.
MPEp is the maximum permissible probing error.
A-4
A-05 (2003) full size 12/15/03 10:25 AM Page 1
Crysta-Apex C Series
CNC Coordinate Measuring Machines.
MPP-100 PM10MQ*
Crysta-Apex C Crysta-Apex C
Accuracy
9108 / 9168 / 9208 121210 / 122010 / 123010
IS010360-2: 2001
MPEE MPEp MPEE MPEp
Temperature 1 TP2 / 20 2.2+3L/1000µm 2.2µm 2.8 + 3L/1000µm 2.6µm
64.4° - 71.6° F TP200 1.9+3L/1000µm 1.9µm 2.5 + 3L/1000µm 2.2µm
(18° to 22° C) MPP100 / SP600 1.7+3L/1000µm 1.7µm 2.3 + 3L/1000µm 2.0µm
Temperature 2 TP2 / 20 2.2+4L/1000µm 2.2µm 2.8 + 4L/1000µm 2.6µm
60.8° - 78.8° F TP200 1.9+4L/1000µm 1.9µm 2.5 + 4L/1000µm 2.2µm
(16° - 26° C) MPP100 / SP600 1.7+4L/1000µm 1.7µm 2.3 + 4L/1000µm 2.0µm
MPEE is the maximum permissible error of indication of a CMM for size measurement.
MPEp is the maximum permissible probing error.
A-5
A-06 (2003) full size 12/8/03 8:41 AM Page 1
Features
• Shop floor oriented
• Excellent cost/performance ratio
• High accuracy
• Real-time Volumetric Error Compensation performed in closed loop
• Complete wrap around covering for guideways and bridges
• Advanced structural design with low mass/high stiffness ratio
• Digital Servo Controller
Specifications
BRIGHT STRATO SERIES
MODEL BRIGHT- BRIGHT- BRIGHT- BRIGHT- BRIGHT- BRIGHT- BRIGHT-
STRATO 707 STRATO 710 STRATO 910 STRATO 916 STRATO 1620 STRATO 1630 STRATO 1640
Measuring X-axis 27.75" (705mm) 35.62" (905mm) 63.18" (1605mm)
Range Y-axis 27.75" (705mm) 39.56" (1005mm) 39.56" (1005mm) 63.18" (1605mm) 78.93" (2005mm) 118.30" (3005mm) 157.67" (4005mm)
Z-axis 23.81" (605mm) 47.44" (1205mm) / 59.25" (1505mm)
Resolution .000004" (0.0001mm)
Drive Speed CNC: Max moving speed = 430 mm/s(3D) Measuring speed = 1~3mm/s CNC: Max moving speed = 500 mm/s(3D) Measuring speed = 1~3mm/s
J/S: Max moving speed = 80 mm/s Measuring speed= 0~3mm/s J/S: Max moving speed = 80 mm/s Measuring speed= 0~3mm/s
Measuring Material Granite stone
Table Size 33.07" x 51.97" 33.07" x 63.78" 40.94" x 67.72" 40.94" x 91.34" 72.83" x 129.13" 72.83" x 168.50" 72.83" x 207.87"
(840 x 1320mm) (840 x 1620mm) (1040 x 1720mm) (1040 x 2320mm) (1850 x 3280mm) (1850 x 4280mm ) (1850 x 5280mm)
Dimensions Width 62.48" (2715mm) 70.35" (1787mm) 115.23" (2937mm)
Depth 60.67" (1541mm) 72.48" (1841mm) 76.42" (1941mm) 105.55" (2681mm) 145.08" (3685mm) 184.45" (4685mm) 223.71" (5685mm)
Height 106.89" (2715mm) 170.87" (4340mm) / 194.49" (4940mm)
Machine Weight 3097 lbs (1405kg) 3604 lbs(1635kg) 4277 lbs (1940kg) 6526 lbs (2960kg) 21054 lbs (9550kg) 30865 lbs (14000kg) 39683 lbs (18000kg)
21165 lbs (9600kg) 30975 lbs (14050kg) 39793 lbs (18050kg)
Accuracy ISO10360-2* E=1.4+3L/1000 µm E=1.7+3L/1000 µm E=3.8+4L/1000 µm / E=4.8+5L/1000 µm
R=1.8µm (As using with TP-200) R=1.9µm (As using TP-200) R=4.0µm / R=5.5µm (As using TP-200)
Temperature Range 64.4°F~71.6°F (18°C ~ 22°C)
Variation 1.8°F (1.0°C) / hour, 9.0°F (5.0°C) / 24 hours 1.8°F (1.0°C) / hour, 3.6°F (2.0°C) / 24 hours
Gradient 1.8°F (1.0°C) /m (Vertically and Horizontally)
*ISO10360-2:1994
E: Indication Accuracy
R: Probing Error
A-6
A-07 (2003) full size 12/8/03 8:43 AM Page 1
Legex Series
Ultra-high-precision CNC CMM
Features
• Extremely high axial measuring accuracy.
• Single moving-column structure for dynamic rigidity.
• Ergonomic design for efficient inspection.
• High-precision air bearings are used for all axial guideways.
• Air-suspended, auto-leveling vibration isolator is provided as
standard equipment.
• Suitable for measuring gages and high-precision parts.
Specifications
LEGEX Series
MODEL LEGEX 707 (Z-450) LEGEX 707 (Z-600) LEGEX 910
X-axis 27.75" (700mm) 35.6" (900mm)
Measuring
Y-axis 27.75" (700mm) 40" (1000mm)
Range
Z-axis 17.9" (450mm) 23.8" (600mm)
Resolution .0000004" (0.00001mm)
CNC: Max moving speed = 200mm/s (3D)
Measuring speed = 1~3mm/s
Drive Speed
J/S: Max moving speed = 80mm/s
Measuring speed = 0~3mm/s
Material Cast iron
Measuring
29.5" x 29.5" 37.4" x 41.3"
Table Size
(750 x 750mm) (950 x 1050mm)
Width 62.48" (1686mm) 74.26" (1886mm)
Dimensions Depth 92.5" (2350mm) 116.2" (2950mm)
Height 102.4" (2600mm) 111.0" (2820mm) 116.5" (2960mm)
Machine Weight 10,030 lbs (4550kg) 10,251 lbs (4650kg) 14,440 lbs (6550kg)
E=0.48+L/1000µm
Accuracy ISO10360-2*
R=0.6µm (As using with MTP2000, TP-7M, MPP300)
Range 64.4°F~71.6°F (18°C~22°C)
Temperature Variation 0.9°F (0.5°C) / 1 hour, 1.8°F (1.0°C) / 24 hours
Gradient 1.8°F (1.0°C) /m (Vertically and Horizontally)
*ISO 10360-2:1994
E: Indication Accuracy
R: Probing Error
A-7
A-08 (2003) full size 12/8/03 8:43 AM Page 1
Mach 403/806
High-Speed CNC
Coordinate Measuring Machines
Designed for In-Line Inspection
Features
• Very High Drive Speed.
• Intended for integration into manufacturing lines.
• Can perform concurrent inspection with certain machine tools.
• Pre- and Post-Machining Feedback.
• High Accuracy Measurement.
• Rugged Design for high speed operation in the shop environment.
• Real Time Temperature Compensation.
• Dedicated Windows® NT based software.
Mach 403
Specifications
MODEL MACH 403-04 MACH 806-10
Measuring range
X-axis 18" (460mm) 40" (1021mm)
Y-axis 18" (460mm) 32" (818mm)
Z-axis 12" (300mm) 24" (615mm)
Resolution .000004" (0.0001mm)
Length Standard Linear encoder
Accuracy* E=3.5 + 4.0L/1000µm
ISO 10360-2:1994 59°F~77°F (15°C to 25°C)
E: Indication Accuracy E=5.0 + 5.0L/1000µm
50°F~95°F (10°C to 35°C)
Drive Speed 70.86"/s (1800mm/s)
(available with tri-axial motion)
Acceleration 1.8G (available with tri-axial motion)
Probing Speed 1.18"/s (30mm/s)
Max. Workpiece – 3300 lbs.
Mach 806 Weight (1500kg.)
Dimensions**
Width 67.13" 112.1"
(1705mm) (2847mm)
Depth 35.4" 66.9"
(900mm) (1700mm)
Height 66.1" 93.3"
(1679mm) (2370mm)
Mass 2293 lbs. (1040kg) 6173 lbs. (2800kg)
*L: Measuring length (mm)
** MACH 403-04 (excluding machine stand), MACH 806-10 (excluding indexing table)
A-8
A-09 (2003) full size 12/8/03 8:44 AM Page 1
Features
MOTORIZED PROBE HEAD PH10T TP7M
• The new PH10T motorized probe head allows complete, rapid, • The TP7M is a high accuracy touch trigger probe designed to
and repeatable inspection of most complex components with maintain a high level of accurate and reliable performance
minimum human intervention. Full orientation of your TP2, across a wide range of conditions. When used with long styli,
TP6, TP20 or TP200 probe between any of 720 positions, or non-degreased components or at slow speeds, the probe
under manual or program control, turns your 3 axis CMM into is able to maintain this high accuracy.
a 5 axis machine. SP600M
PH10M/PH10MQ (for Crysta-Apex) • SP600M is an autojointed, multiwired analogue scanning
• The PH10M/MQ motorized probe head has been developed probe suitable for mounting on a PH10M motorized head or a
for the new generation of contact and non-contact scanning PH6M fixed probe head. It enables a CMM to gather large
probes. It has three times the torque, allowing probe exten- amounts of data very rapidly for inspection or digitizing pur-
sion bars up to 300mm long to be used. The PH10M/MQ has poses by a number of methods.
an autojoint mounting. AUTOCHANGE
TP200 • Renishaw’s “Autochange” is the world’s first integrated probe
• The sensor technology employed in the TP200 gives submi- change system. Mounted within the CMM’s working enve-
cron measurement performance and eliminates the ‘lobing’ lope, Autochange facilitates fast, automatic probe exchange
characteristics encountered when using standard probes. without redatuming.
Repeatable stylus changing can be carried out either manu- MPP-100 & MPP-300
ally or automatically under high speed DCC CMM control • The MPP-100 & 300 are continuous path contact-type scan-
with the SCR200 stylus changing rack. ning probes designed to output three-axis displacement, and
PH-50 support an autostylus changer. The MPP-100 is a high speed
• The PH-50 motorized probe head system is a compact ver- and accuracy scanning probe. The MPP-300 is an ultra high
satile probing system. accuracy scanning probe with LEGEX.
A-9
A-10 (2003) full size 12/8/03 8:36 AM Page 1
Features MIP
• Ball probe, taper probe, cylindrical probe • The MIP is indexable in two axes (A and B) with
increments clearly marked, enabling users to easily
• Centering microscope, TV monitor system return to prequalified probe tip positions.
MANUAL PROBE HEADS TP1(S) • Positioning of the probe tip is easy…simply unlock
• TP1(S) features a maintenance free, sealed construc- both axes with a single lever rotation, and move to
tion with specially formulated lubricants for a long the required position by rotating the A and B axes.
working life. It has an M3 stylus fixing, compatible with When in place, a further lever rotation locks both
Renishaw’s wide range of styli and accessories. axes, ensuring a positional repeatability of 1.5µm (2s).
TP2 MH8
• TP2’s compact dimensions (13mm diameter) are • Can be used with TP6 probe directly or TP2 probe
ideal for probing into restricted component features, with up to 50mm extension. Allows extended reach
especially when used in conjunction with Renishaw into deep features.
probe heads and extension bars (M8 screw fixing). MH20
THE MANUAL INDEXABLE HEAD (MIH) • The MH20 is manually operated probe heads that
• The MIH is adjustable in two axes, both of which articulate to provide orientation of the probing axis
can be unlocked by a single operation thumbwheel. and compatible with the TP20 stylus modules.
A probe/stylus combination can be orientated to 720 TV MONITOR SYSTEM
different positions and once the head is locked, that • TV monitor system is a unique optical video package
position will be repeatable to 1µm. that delivers zoom microscope type viewing in the
20X to 250X range.
A-10
A-11 (2003) full size 12/8/03 12:22 PM Page 1
MiCAT uses the same operating method for both manual and
CNC Coordinate Measuring Machines, and generates graph-
ic displays of the various measured elements. The on/off sta-
tus, size and layout of windows can be easily customized for
optimum usability, and allows operators to be as productive as
possible with this user-friendly suite of modular software.
A-11
B-01 (2003) full size 12/11/03 3:56 PM Page 1
Form Measuring
(Surface Roughness Instruments)
FORMPAK-SV B-15
Specifications
Model No. CS-5000 CS-5000L
Measuring Range X-axis 8" (200mm)
Z-axis .24" (6mm) / .47" (12mm)* .47" (12mm) / .94" (24mm)*
Column 10" (250mm)
Resolution X-axis .25µinch (0.00625µm)
Z-axis .08µinch (0.002µm) / .16µinch (0.004µm)* .16µinch (0.004µm) / .32µinch (0.008µm)*
Accuracy (at 20˚C) X-axis ±(7.8 + L)µinch [±(0.2+0.001L)µm]
Z-axis**** ±(7.8+15H)µinch [±(0.2+0.005H)µm] ±(12+20H)µinch [±(0.3+0.02H)µm]
Straightness X-axis**** (2+0.5L)µinch [(0.05+0.0005L)µm] (4+1.5L)µinch [(0.1+0.0015L)µm]
Detection method X- and Z-axis Laser Holoscale
Stylus tip orientation Downward
Feed direction Both backward and forward
Measuring force active control 4mN(constant) 4mN/0.75mN* (constant)
Power consumption Max. 150VA (except for PC and printer)
Dimensions Measuring unit 30.1 x 17.7 x 35" (765 x 450 x 890mm)
(W x D x H) Control unit 9.8 x 15 x 11.8" (250 x 380 x 300mm)**
Vibration isolator 44.5 x 24.8 x 30" (1130 x 630 x 760mm)
Mass Measuring unit 308 Ibs. (140kg)
Control unit 15.4 Ibs. (7kg)***
Vibration isolator 286 Ibs. (130kg)**
*When using a long stylus ** Stored inside the vibration isolator *** Including the windshield cover **** When using standard stylus
L = Traverse length (mm) H = Measuring height (mm)
B-2
B-03 (2003) full size 12/8/03 9:01 AM Page 1
Formtracer CS-3000
The CS-3000 is a high price-performance
ration model in the Mitutoyo Formtracer
series. This can provide a measurement
solution for the small size workpieces that
required hybrid form (surface/contour)
measurement with middle-class accuracy.
Features
• Hybrid surface/contour measurement and
analysis with a single trace of workpiece.
• Wide range and high resolution detector.
• Control box for remote operation.
• Analysis software “FORMTRACEPAK”.
Specifications
Model No. CS-3000S4
Measuring Range X-axis 4" (100mm)
Z-axis .2" [Resolution: 3µinch] (5mm [Resolution: 0.08µm])
.02” [Resolution: 3µinch] (0.5mm [Resolution: 0.008µm])
.002” [Resolution: .03µinch] (0.05mm [Resolution: 0.0008µm])
Column 11.8" (300mm)
Accuracy X-axis ±(1 + 2L/100)µm (L=traverse length)
Z-axis ±118µinch / .197" (±3µm / 5mm)
Straightness ± 8µinch / 4" (±0.2µm / 100mm)
Moving speed X-axis .004"/s (0.1mm/s) to .2"/s (5mm/s)
Column .004"/s (0.1mm/s) to .2"/s (5mm/s)
Measuring force 0.75mN
Power consumption Max. 150VA (except for PC and printer)
Dimensions Measuring unit 28 x 17.7 x 35.6" (710 x 450 x 905mm)
(W x D x H) Control unit 7.09 x 15 x 11.8" (180 x 380 x 300mm)
Mass Measuring unit 309 Ibs. (140kg)
Control unit 14 Ibs. (6.5kg)
B-3
B-04 (2003) full size 12/8/03 9:02 AM Page 1
Specifications
Model No. SV-C3000S4 SV-C3000H4 SV-C3000W4 SV-C3000S8 SV-C3000H8 SV-C3000W8
SV-C4000S4 SV-C4000H4 SV-C4000W4 SV-C4000S8 SV-C4000H8 SV-C4000W8
X-axis traverse/ 4" (100mm) 8" (200mm)
measuring range
Vertical traverse 10" (250mm) 18" (450mm) 18" (450mm) 10" (250mm) 18" (450mm) 18" (450mm)
of drive unit
Machine base type Granite Cast iron Granite Cast iron
(600 x 450mm) (1000 x 450mm) (600 x 450mm) (1000 x 450mm)
Power consumption 150VA (at max)
Dimensions - Main unit 38.76 x 17.7 x 35.63" 38.76 x 17.7 x 43.5" 53.6 x 17.7 x 43.5" 39.78 x 17.7 x 35.63" 39.78 x 17.7 x 43.5" 54.62 x 17.7 x 43.5"
(W x D x H) (984.4 x 450 x 905mm)(984.4 x 450 x 1105mm)(1361.4 x 450 x 1105mm)(1010.4 x 450 x 905mm)(1010.4 x 450 x 1105mm) (1387.4 x 450 x 1105mm)
Mass - Main unit 308 lbs. (140kg) 330 lbs. (150kg) 341 lbs. (155kg) 319 lbs. (145kg) 341 lbs. (155kg) 352 lbs. (160kg)
B-4
B-05 (2003) full size 12/8/03 9:11 AM Page 1
Auto-leveling tables
FORMTRACER
Traverse table SV-C3000/4000 Series
178-027 178-044(mm)
178-054(inch)
Rolling unit
178-036
178-028
For contour
For surface roughness measurement,
XY leveling table measurement, interchangeable
178-043-1 (mm) interchangeable styli and arms
178-053-1 (inch) styli and nosepieces
Precision vise
178-019 V-block
Step gage 998291
178-611(mm) Symmetry Rotary vise Center support
178-612(inch) calibration gages 172-144 Holder V-block
172-142 with clamp
Rotary table Swivel with clamp
center support 176-107 172-378
211-016 172-196 V-block
172-197
with clamp
Metric 4-step gage Rotary vise 172-234
178-610 997996 218-003 Center support rizer
172-143
B-5
B-06 (2003) full size 12/8/03 9:12 AM Page 1
Specifications
Model No. SV-2000N2 SV-2000S2 SV-3000M4 SV-3000S4 SV-3000H4 SV-3000W4
Traverse range 2" (50mm) 4" (100mm)
Linearity of traverse 12µinch/2" 12µinch/4" 2+1.5Lµinch
(0.3µm/50mm) (0.3µm/100mm) (0.05+1.5Lµm/1000µm)
Vertical travel – 11.8" (300mm) 11.8" (300mm) 11.8" (300mm) 19.7" (500mm)
Power column Manual column Power column Power column
Base size (W x D) – 24.1 x 17.7" 24 x 17.7" 28 x 17.7" 43.3 x 17.7"
(613 x 450mm) (610 x 450mm) (710 x 450mm) (1100 x 450mm)
Measuring range 32000µinch [Resolution: .4µinch] 800µm [Resolution: 0.01µm]
3200µinch [Resolution: .04µinch] 80µm [Resolution: 0.001µm]
320µinch [Resolution: .004µinch] 8µm [Resolution: 0.0001µm]
Dimensions - Main unit 10.35 x 3.2 x 5.5" 24.33 x 17.72 x 33" 29.92 x 17.72 x 27.99" 27.95 x 17.72 x 35.04" 27.95 x 17.72 x 42.91" 43.3 x 17.72 x 42.91"
(W x D x H) (263 x 82 x 140mm) (618 x 450 x 905mm) (760 x 450 x 711mm) (710 x 450 x 890mm) (710 x 450 x 1090mm) (1100x450x1090mm)
Mass - Main unit 6.16 lbs. (2.8kg) 286 lbs. (130kg) 308 lbs. (140kg) 308 lbs. (140kg) 330 lbs. (150kg) 341 lbs. (155kg)
B-6
B-07 (2003) full size 12/8/03 9:11 AM Page 1
Indicator
Easy and speedy with a touch panel of Z-axis
(stylus
position)
Touch panel-type
Measurement X and Y-axis
surface roughness- result window counter
analyzing unit
Main window
Features
• Employing a 12-inch color LCD
• Large sized and easy-to-understand
icons allow high-level analysis as well
as SURFPAK-SV with facility.
Recalculation window
Printout
B-7
B-08 (2003) full size 12/8/03 9:13 AM Page 1
Surftest SJ-401/402
Features
• High-accuracy measurements with a hand-held tester.
• Confirmation of a measurement results and an
assessed profile without printout.
SJ-402
Calculation Result screen Measured Profile screen
SJ-401
SJ-401
Specifications
Model SJ-401 SJ-402
Order No. 178-947-2A 178-945-2A
Measuring method Skidless/Skid measurement
Measuring range Z-axis 32000µin, 3200µin, 320µin (800µm, 80µm, 8µm) (Up to 2,400µm with an option stylus)
X-axis 1" (25mm) 2" (50mm)
Drive method Straightness 12µin/1" (0.3µm/25mm) 20µin/2" (0.5µm/50mm)
Height-Tilt Tilt adjustment range ±1.5˚
adjustment unit
Height adjustment amount .39" (10mm)
Assessed profile Primary profile (P), Roughness profile (R), Filtered waviness profile (W),
DIN4776, MOTIF (R, W)
Evaluation parameter Ra, Ry, Rz, Rq, Pc, R3z, mr, Rt, Rp, Rv, Sm, S, δc, Rk, Rpk, Rvk, Mr1, Mr2, A1,
A2, Lo, Ppi, R, AR, Rx, ∆a, ∆q, Ku, HSC, mrd, Sk, W, AW, Wte, Wx, Vo
Analysis graph Bearing Area Curve (BAC), Amplitude Distribution Curve (ADC)
Cut-off length 003, .01, .03, .1, .3" (0.08, 0.25, 0.8, 2.5, 8mm)
Digital filter 2CR, PC75 (phase corrected), Gauss
Number of sampling length X1, X3, X5, XL* (*=arbitrary length)
Arbitrary length SJ-401: .01" to 1" (.01" increments) [0.1 to 25mm (0.1mm increments)]
SJ-402: .01" to 2" (.01" increments) [0.1 to 50mm (0.1mm increments)]
Sampling length (L) .003, .01, .03, .1, .3" (0.08, 0.25, 0.8, 2.5, 8mm)
Detector Detection method Differential inductance method
Minimum resolution .005µin (320µin range) / 0.000125µm (8µm range)
Printer Thermal printer
Power supply Via AC adapter, built-in rechargeable battery (Ni-H)
Battery Charging time 15 hours
Number of measurement 600 maximum without printing
Power consumption 43W (max.)
Dimensions Control unit 12.09 x 6.50 x 3.7" (307 x 165 x 94mm)
Height-Tilt adjustment unit 5.16 x 2.48 x 3.90" (131 x 63 x 99mm)
Drive unit 5.04 x 1.42 x 1.85" 6.08 x 1.41 x 1.84"
(128 x 36 x 47mm) (155 x 36 x 47mm)
Roughness standard JIS (JIS B0601-1994/1982), DIN, ISO, ANSI
LCD size Touch panel
Data output RS-232C input/output, SPC output
External control Connection to the data processing system (option)
Mass Control unit 2.64lbs. (1.2kg)
Height-Tilt adjustment unit 1.88lbs. (0.4kg)
Drive unit 1.32lbs. (0.6kg) 1.41lbs. (0.64kg)
B-8
B-09 (2003) full size 12/8/03 9:14 AM Page 1
SURFTEST
Detector SPC connecting cable
936937 (1m)
965014 (2m)
Input tool
IT-005D 264-005
SJ-401/402
Cylinder attachment
12AAB358 XY Leveling Tables
Surfpak-SJ
Carrying case
(standard accessory)
B-9
B-10 (2003) full size 12/8/03 8:59 AM Page 1
Surftest SJ-301
Features
• Conforming to various standards
• Storing measurement conditions and data
• Reading profiles in the LCD window
• High-speed thermal printer
• Statistical analysis functions
• Auto calibration
• GO/NG judgement function
• Customization function
• Arbitrary evaluation length SJ-301
• One-step detector replacement 178-953
• Selectable language for display/printout
Specifications
Model SJ-301 SJ-201P
Order No. 178-954-2A 178-923A
Measuring range Z-axis 12000µin (350µm)
X-axis .5" (12.5mm)
Assessed profile Primary profile (P), Primary profile (P),
Roughness profile (R), Roughness profile (R),
DIN4776, MOTIF (R, W) DIN4776 profile
Evaluation parameter Ra, Ry, Rz, Rt, Rp, Rq, Rv, Sm, S, Ra, Ry, Rz, Rq, Sm, S, Pc, R3z,
Pc, R3z, mr, Rpk, Rvk, σc, Rk, Mr1, Mr2, mr, Rt, Rp, Rk, Rpk, Rvk, Mr1, Mr2,
Lo, Ppi, R, AR, Rx, A1, A2, Vo, A1, A2, Vo
HSC, mrd, Sk, Ku, ∆a, ∆q, Wte, Wx, W, AW
Analysis graph BAC1, BAC2, ADC
Digital filter 2CR-75% (without phase compensation), PC-75%, PC 50% (Gaussian)
Cut-off length .01, .03, .1, .3" (0.25, 0.8, 2.5, 8mm) .01, .03, .1" (0.25, 0.8, 2.5mm)
Number of sampling spans X1, X3, X5, XL (arbitrary length)
Arbitrary length 0.01 ~ 0. 49" (0.3 ~ 12.5mm)
Sampling length L: .01, .03, .1, .3" (0.25, 0.8, 2.5, 8mm) L: .01, .03, .1" (0.25, 0.8, 2.5mm)
Printer Thermal printer (Printing width: 1.89" (48mm)
Power supply Via AC adapter, built-in rechargeable battery
Rechargeable battery Charging time: 15 hours Charging time: 12 hours
(for 600 measurements without printing) (for 500 measurements)
Power consumption 43W (max.) DC6V-1.5W
Dimensions Display unit 12.09 x 6.50 x 3.7" (307 x 165 x 94mm) 6.16 x 2.44 x 2.05" (156.5 x 62 x 52mm)
Drive unit 4.53 x .91 x 1.02" (115 x 23 x 26mm)
Mass Display unit 2.64lbs. (1.2kg) .64lbs. (0.3kg)
Drive unit .42lbs. (0.2kg)
Remarks Roughness standard JIS (JIS B0601-1994/1982), DIN, ISO, ANSI
Data output Via RS-232C interface unit, SPC output
B-10
B-11 (2003) full size 12/8/03 8:58 AM Page 1
Surftest SJ-201P
Features
• Conforming to various standards • Mobility
• Auto calibration • Arbitrary evaluation length
• GO/NG judgement function • One-step detector replacement
• Customization function SJ-201P
178-930
Memory card
(for SJ-301)
12AAA841
Height gage
adapter
12AAA222 (mm)
12AAA233 (inch)
SPC connecting cable
SJ-201P SJ-301
Input tool
965014 79" (2m)
IT-005D 264-005 Magnetic
936937 39" (1m)
stand
adapter
12AAA221 (mm)
12AAA220 (inch)
DP-1VR
264-504
Setting attachments
B-11
B-12 (2003) full size 12/8/03 9:01 AM Page 1
B-12
B-12 (2003) full size 12/8/03 9:01 AM Page 1
B-12
B-13 (2003) full size 12/8/03 9:02 AM Page 1
• SURFPAK®-SV dedicated analysis software allows • The dedicated analysis software, FORMPAK®-1000,
57 types of parameters that conform to international allows easy calculation, tolerancing, and analysis
standards, including ISO, DIN, ANSI, and JIS to be of two-dimensional coordinate (contour) data
analyzed. obtained by measuring geometric elements such
• This system supports 10 types of measured profiles, as points, lines, circles, angles, and pitches.
including the roughness profile, primary profile, and • In the Formtracer, a high-accuracy linear scale is
waviness profile, and 2 types of motifs. installed on the X axis and also in the Z-axis
• The system supports 7 types of digital filters, detecting unit. Since high-resolution measurement
including a Gaussian filter. can always be performed at full stroke, the measuring
magnification does not need to be changed. The unit
• Various analysis graphs such as the bearing area can efficiently measure various workpiece sizes.
curve (BAC) and amplitude distribution graph are
easily displayed. • There are two models: the SV-C3000 series
(standard type) which has a Z-axis resolution of
• The system can delete unnecessary data such as 0.2µm, and the SV-C4000 series (high-accuracy
scratches and assess an inclination and a rounded type) which has a resolution of 0.05µm.
surface after digital compensation.
• The X-axis drive unit has excellent straightness
• The system has a wide measuring range of a which guarantees high-accuracy.
maximum of 800µm.
• The system can compare measured data with
• An auto-leveling table (option), which automatically nominal data or two pieces of measured data,
levels a workpiece measuring surface, can be mounted. and then display the deviation. Not only can the
• The system supports optional software including coordinate value and specific dimension be
the fine contour measuring program (FORMPAK®-SV). measured, but the form can also be assessed
and the wear condition can be observed for the
• Report generation function (printer is optional.)
entire workpiece.
• Report generation function (printer is optional)
B-13
B-14 (2003) full size 12/8/03 9:03 AM Page 1
FORMPAK®-SV
B-14
B-15 (2003) full size 12/8/03 9:12 AM Page 1
FORMPAK®-SV
Features
• Evaluates the fine texture of the workpiece surface that cannot
be evaluated in the surface roughness parameters.
• Performs various analysis/evaluations including the contour
evaluation of step and pitch and the calculation of areas.
Data display
window
Command
icons
Operation guide
window
Operation
procedure Measurement
window result window
B-15
B-16 (2003) full size 12/8/03 9:13 AM Page 1
B-16
B-17 (2003) full size 12/8/03 9:13 AM Page 1
B-17
B-18 (2003) full size 12/8/03 9:14 AM Page 1
Auto-leveling Table
Leveling a workpiece for skidless measurement at high magnification
requires skill and is time-consuming. Electrical correction for the
inclination may involve errors depending on the method or the material
of the workpiece, and on the radius of curvature of the stylus tip. The
Auto-leveling Table solves these problems and allows exact workpiece
leveling easily and quickly.
178-047
3-axis Adjustment Table
178-042-1 (metric)
178-052-1 (inch/metric) 998055
B-18
C-01 (2003) full size 12/11/03 3:55 PM Page 1
Form Measuring
(Contour Instruments)
FORMPAK-1000 C-4
FORM MEASURING
CV-4000
CV-3000
Specifications
Order No. CV-3000S4/4000S4 CV-3000H4/4000H4 CV-3000W4/4000W4 CV-3000S8/4000S8 CV-3000H8/4000H8 CV-3000W8/4000W8
Measuring X-axis 4" (100mm) 8" (200mm)
range Z-axis 2" (50mm) 2" (50mm)
Resolution X-axis 2µ inch (0.05µm)
Z-axis CV-3000 Models 8µ inch (0.2µm)
CV-4000 Models 2µ inch (0.05µm)
Measuring X-axis CV-3000S4/H4/W4: ±(1+2L/100)µm [±(40+20L)µinch]* CV-3000S8/H8/W8: ±(1+4L/200)µm [±(40+20L)µinch]*
CV-4000S4/H4/W4: ±(0.8+2L/100)µm [±(31+20L)µinch]* CV-4000S8/H8/W8: ±(0.8+4L/200)µm [±(31+20L)µinch]*
accuracy (20°C) Z-axis CV-3000 Models: ±(3+|2H|/25)µm [±120+|40H|)µinch]** CV-4000 Models: ±(0.8+|0.5H|/25)µm [±(31+|10H|)µinch]**
Linearity of drive unit 32µinch/4" (0.8µm/100mm) 80µinch/8" (2µm/200mm)
Drive unit vertical travel 10" (250mm) 18" (450mm) 10" (250mm) 18" (450mm)
Drive unit inclination range ±45 degrees
Stylus tip orientation Downward/upward
Traversing direction Forward/backward
Measuring force 30mN (3gf)
Moving speed .2"/s (5mm/s)
Power consumption 150VA (at maximum)
Dimensions Main unit 29.17x17.7x35.63" 29.17x17.7x43.5" 44.02x17.7x43.5" 30.2x17.7x35.63" 30.2x17.7x43.5" 45.04x17.7x43.5"
(W x D x H) (741x450x905mm) (741x450x1105mm) (1118x450x1105mm) (767x450x905mm) (767x450x1105mm) (1144x450x1105mm)
Electronic unit 7.1 x 15 x 11.8" (180 x 380 x 300mm)
Control box 9.6 x 4.6 x 3.1" (245 x 116 x 78mm)
Mass Main unit 308 lbs. (140kg) 330 lbs. (150kg) 330 lbs. (150kg) 319 lbs. (145kg) 341 lbs. (155kg) 341 lbs. (155kg)
Electronic unit 14.3 lbs. (6.5kg)
Control box 1.76 lbs. (0.8kg)
* L=Traverse length (inch [mm])
** Z=Measuring height (within ±1 inch [±25mm])
C-2
C-03 (2003) full size 12/8/03 2:58 PM Page 1
FORM MEASURING
Contracer CV-1000/2000
CV-1000N2 can be attached
to the optional stand.
CV-2000M4
Features
• Mitutoyo digitizes the X- and Z-axes
over the full range, giving you a
wider range of measurement with
higher resolution. No more reliance
on measurement magnifications!
*MP5300 (Graphtec)
Specifications
Model CV-1000N2 CV-2000M4
Measuring X-axis 2" (50mm) 4" (100mm)
range Z-axis 1" (25mm) 1.5" (40mm)
Resolution X-axis .008µinch (0.2µm)
Z-axis .016µinch (0.4µm) .02µinch (0.5µm)
Measuring X-axis (138 + 20L)µinch [(3.5 + 0.02L)µm]*
accuracy Z-axis ±(138 + 157H)µinch [±(3.5 + 4H/25)µm]**
Straightness .14µinch/2" (3.5µm/50mm) .14µinch/4" (3.5µm/100mm)
Stylus tip orientation Downward
Traversing direction Forward
Measuring force 10 to 30mN (1 to 3gf)
Moving speed X-axis .008"/s (0.2mm/s) or .04"/s (1mm/s)
Power consumption 150VA (at maximum)
Dimensions Main unit 19.30 x 7.01 x 5.43" 23.62 x 17.71 x 18.80"
(W x D x H) (490 x 178 x 138mm) (600 x 450 x 740mm)
Electronic unit 12.05 x 6.50 x 3.11" (306 x 165 x 79mm)
Mass Main unit 11 lbs. (5kg) 255 lbs. (115.8kg)
Electronic unit 11 lbs. (5kg)
* L = Traverse length (inch [mm])
** H = Measuring height from the horizontal (within ±.5 inch [±12.5mm])
C-3
C-04 (2003) full size 12/8/03 3:01 PM Page 1
FORM MEASURING
C-4
C-05 (2003) full size 12/8/03 2:58 PM Page 1
FORM MEASURING
Optional arms
Optional styli
218-007
178-023
218-024
(CV-1000 only)
211-016 997996 178-019 998291
166-215
Others (CV-1000/2000)
Electronic unit
218-341A
RAM card
12AAA841
Measuring stand
218-024
Pin gage unit
998861 (inch)
998862 (mm)
C-5
C-06 (2003) full size 12/8/03 3:02 PM Page 1
FORM MEASURING
Arms
996504 for .24" (6mm) high stylus 996509 for .24" (6mm) high stylus 996514
996505 for .47" (12mm) high stylus 9965010 for .47" (12mm) high stylus
996506* for .79" (20mm) high stylus 9965011 for .79" (20mm) high stylus
996507 for 1.18" (30mm) high stylus 9965012 for 1.18" (30mm) high stylus
996508 for 1.65" (42mm) high stylus 9965013 for 1.65" (42mm) high stylus
*Standard accessory
For CV-1000/2000
Straight Type Eccentric Type For Small Hole Stylus
3.74"
Stylus 6.10" .59" (
15) .98"
Stylus (95)
) (155) (25)
Stylus 6.10" .59" (15 1.5 5.71 "
(155) 7"
(40 (145)
)
935111 for .24" (6mm) high stylus 935116 for .24" (6mm) high stylus 935110
935112 for .47" (12mm) high stylus 935117 for .47" (12mm) high stylus
935113* for .79" (20mm) high stylus 935118 for .79" (20mm) high stylus
935114 for 1.18" (30mm) high stylus 935119 for 1.18" (30mm) high stylus
935115 for 1.65" (42mm) high stylus 935120 for 1.65" (42mm) high stylus
*Standard accessory
C-6
C-07 (2003) full size 12/8/03 3:03 PM Page 1
FORM MEASURING
Styli
Small hole
.02" (0.4)
.10" (2.5)
.04" (1)
.51" .79"
2.17" 2.17" 2.17"
(13) (55) (20)
(55) (55)
For CV-1000/2000
Small hole
.10" (2.5)
.02" (0.4)
)
(40
.04" (1)
C-7
C-08 (2003) full size 12/8/03 3:02 PM Page 1
FORM MEASURING
Styli
H H H
H H H
Diamond
C-8
C-09 (2003) full size 12/8/03 3:03 PM Page 1
FORM MEASURING
Optional Accessories
Rugged tables Rotary vises Rotary table Holder with clamp
Cross-travel table Rotary vise Rotary table Holder with clamp
• Table top: 11 x 7" (280 x 180mm) • Two-slide jaw type • Table top: ø5.7" (146mm) DIA. • Used with a cross-travel table or
• XY travel: 4 x 2" (100 x 50mm) • Max. workpiece size: ø2.4" (60mm) • Minimum reading: 2° rugged table.
• Minimum reading: 1° • Holder with clamp (176-107) • Max. workpiece height: 1.3" (35mm)
can be mounted.
218-003
Rotary vise
Center supports
Cross-travel table
• One-slide jaw type
• Table top: 11 x 6" (280 x 152mm)
• Max. workpiece size: ø2.4" (60mm)
V-blocks Swivel center support
• XY travel: 2 x 1" (50 x 25mm) • Max. workpiece diameter: 3.1" (80mm)
• Minimum reading: 5° V-block with clamp (2.5" (65mm) when swiveled 10°)
• Used with a cross-travel table or • Max. workpiece length: 5.5" (140mm)
rugged table.
• Max. workpiece diameter: 2" (50mm)
172-144
172-234
218-051 (inch)
218-041 (mm) 172-197
Center support
Rugged table
Leveling tables
• Max. workpiece diameter: 4.7" (120mm)
• Table top: 11 x 7" (280 x 180mm) XY leveling table with swivel • 2.3" (60mm) rizer is optional (172-143)
• Provided with T-grooves for • Table top: 5 x 4" (130 x 100mm)
mounting workpiece fixtures. V-block with clamp
• Leveling range: ±1.5°
• XY travel: ±.5" (12.5mm) • Used with a cross-travel table or
rugged table.
• Max. workpiece diameter: 1" (25mm)
172-378 172-142
178-019
178-023
181-901 (inch)
178-052-1 (inch/mm) 181-902 (mm)
178-042-1 (mm)
C-9
D-01 (2003) full size 12/11/03 3:54 PM Page 1
Form Measuring
(Roundness Instruments)
FORM MEASURING
Features
The Roundtest RA-H5000AS/AH has been developed
by Mitutoyo to provide the world’s greatest degree of
accuracy in roundness measurement. High precision
has been achieved without sacrificing speed through a
process involving constant redesign, prototyping and
experimentation. This development is based on Mitutoyo’s
years of experience in the industry, along with cutting-
edge technology in the field of shape measurement.
RA-H5000AS
and optional accessories
Specifications
Model RA-5000AS RAH-5000AH
Turntable Rotational accuracy* (0.8 + 0.6H)µinch [(0.02 + 6H/10000)µm]
H = Probing height (inch [mm])
Rotating speed 2rpm, 4rpm, 6rpm, 10rpm (20rpm during automatic centering)
Working diameter ø11.81" (300mm)
Centering range ±.2" (5mm)
Leveling range ±1°
Max. workpiece diameter ø26.77" (680mm)
Max. workpiece weight 176 lbs. (80kg) [143 lbs. (65kg) during automatic centering]
Vertical column Straightness** 12µinch/13.77" (0.3µm/350mm) 19µinch/21.65" (0.47µm/550mm)
(Z-axis) Parallelism w/rotating axis 8µinch/13.77" (0.2µm/350mm) 13µinch/21.65" (0.32µm/550mm)
Vertical travel 13.77" (350mm) 21.65" (550mm)
Positioning speed Up to 1.18"/s (30mm/s) with joystick operation (Manual feed available)
Measuring speed .02"/s (0.5mm/s) .04"/s (1mm/s) .08"/s (2mm/s) .2"/s (5mm/s)
Horizontal arm Straightness** 20µinch/7.87" (0.5µm/200mm)
(X-axis) Squareness against rotating axis 20µinch/7.87" (0.5µm/200mm)
Horizontal travel 8.85" (225mm)***
Positioning speed Up to .78"/s (20mm/s) with joystick operation (Manual feed available)
Measuring speed .04"/s (1mm/s) .2"/s (5mm/s)
Air supply Air pressure 4kgf/cm2 (390kPa)
Air consumption 45 liters per minute
Probe and stylus Measuring range ±.012" (±300µm)
Measuring force 0.7 to 1gf (7 to 10mN)
Measuring direction Two-directional
Stylus angle adjustment ±45° (with graduations)
Electronic unit Power consumption 200Va max. (without personal computer)
Dimensions (W x D x H)/mass 18.90 x 12.80 x 7.09" (480 x 325 x 180mm) / 33 lbs. (15kg)
Dimensions Set w/Standard stand 37.17 x 26.46 x 66.93" 37.17 x 26.46 x 74.80"
(W x D x H) (944 x 672 x1700mm) (944 x 672 x1900mm)
Set w/ Vibration damping stand 38.58 x 27.95 x 66.93" 38.58 x 27.95 x 74.80"
(980 x 710 x1700mm) (980 x 710 x1700mm)
Mass Set w/Standard stand 1650 lbs. (750kg) 1694 lbs. (770kg)
Set w/ Vibration damping stand 1804 lbs. (820kg) 1848 lbs. (840kg)
* According to JIS B7451-1997 ** Roughness component cutoff valve: 2.5mm *** Including a protrusion of 1" (25mm) over the turntable rotation center.
Note: Use an optional auxiliary workpiece stand (356038) for measuring a workpiece whose diameter is .8" (20mm) or shorter and whose height is .8" (20mm) or lower.
D-2
D-03 (2003) full size 12/8/03 3:06 PM Page 1
FORM MEASURING
Features
The Roundtest RA-2000 Series has been developed
by Mitutoyo to quest a high accuracy, high speed and high
performance in roundness measurement.The fully-auto- RA-2000AS
matic or a DAT (Digital Adjustment Table) function aided and optional accessories
manual workpiece centering and leveling turns what used
to be a difficult and finicky task into one that is simple
enough for even untrained users to perform. This facili-
tates substantial reductions in overall measurement time.
Specifications
Model RA-2000AS RA-2000DS RA-2000AH RA-2000DH
Workpiece Automatic • •
centering/leveling Manual (DAT function aided) • •
Turntable Rotational accuracy* (0.8 + 0.6H)µinch [(0.02 + 6H/10000)µm] H = Probing height (inch [mm])
Rotating speed 2rpm, 4rpm, 6rpm, 10rpm
Working diameter ø9.25" (235mm) ø7.87" (200mm) ø9.25" (235mm) ø7.87" (200mm)
Centering range ±.1" (3mm) ±.19" (5mm) ±.1" (3mm) ±.19" (5mm)
Leveling range ±1°
Max. workpiece diameter ø22.83" (580mm)
Max. workpiece weight 66 lbs. (30kg)
Vertical column Straightness** 32µinch/11.02" (0.8µm/280mm) 47µinch/18.19" (1.2µm/480mm)
(Z-axis) Parallelism w/rotating axis 39µinch/11.02" (1.0µm/280mm) 67µinch/18.19" (1.7µm/480mm)
Vertical travel 11.02" (280mm) 18.9" (480mm)
Positioning speed Up to .47"/s (12mm/s) with joystick operation (Manual feed available)
Measuring speed .02"/s (0.5mm/s) .04"/s (1mm/s) .08"/s (2mm/s) .2"/s (5mm/s)
Horizontal arm Straightness** 39µinch/5.9" (1.0µm/150mm)
(X-axis) Squareness against rotating axis 39µinch/5.9" (1.0µm/150mm)
Horizontal travel 6.9" (175mm)***
Positioning speed Up to .31"/s (8mm/s) with joystick operation (Manual feed available)
Measuring speed .04"/s (1mm/s) .2"/s (5mm/s)
Air supply Air pressure 4kgf/cm2 (390kPa)
Air consumption 30 liters per minute
Probe and stylus Measuring range ±.012" (±300µm)
Measuring force 0.7 to 1gf (7 to 10mN)
Measuring direction Two-directional
Stylus angle adjustment ±45° (with graduations)
Electronic unit Power consumption 200Va max. (without personal computer)
Dimensions (W x D x H)/mass 18.90 x 12.80 x 7.09" (480 x 325 x 180mm) / 33 lbs. (15kg)
Dimensions 26.26 x 18.7 x 35.43" 26.26 x 18.7 x 43.31"
(W x D x H) (667 x 475 x 900mm) (667 x 475 x 1100mm)
Mass 396 lbs. (180kg) 440 lbs. (200kg)
* According to JIS B7451-1997 ** Roughness component cutoff valve: 2.5mm *** Including a protrusion of 1" (25mm) over the turntable rotation center.
Note: Use an optional auxiliary workpiece stand (356038) for measuring a workpiece whose diameter is .8" (20mm) or shorter and whose height is .8" (20mm) or lower.
D-3
D-04 (2003) full size 12/8/03 3:06 PM Page 1
FORM MEASURING
Roundtest RA-1400/1500
RA-1500
Features
• Suitable for small-size workpieces measurement
• The turntable which is suspended by a high-precision
airbearing has highly accurate rotation and is free from
performance deterioration due to wear.
• Improved the measuring safety with a safety device to the
detector holder arm
Specifications
Model No. RA-1500 RA-1400
Turntable Rotating accuracy* (.8+.6H) µinch [(0.02+6H/10000)µm]
H: Probing height (inch[mm])
Rotational speed 4, 6, 10rpm
Working diameter ø5.9" (ø150mm)
Centering ±.1" (±.3mm)
Leveling ±1º
Maximum workpiece diameter ø15.75" (ø400mm)
Maximum workpiece weight 22lbs (10kg)
Vertical column Straightness** 11.8µinch/5.9" (0.3µm/150mm) –
(Z-axis) Parallelism 11.8µinch/5.9" (0.3µm/150mm) –
Vertical travel 5.9" (150mm)
Positioning speed Up to .59"/s (15mm/s) with joystick operation (Manual feed available)
Measuring speed (0.5, 1, 2, 5mm/s)
Horizontal arm Horizontal travel 2.95" (75mm)***
(X-axis) Positioning speed Up to .31"/s (8m/s) with joystick operation (Manual feed available)
Air supply Air pressure 4kgf/cm2 (390kPa)
Air consumption 30L/min
Probe and stylus Measuring range ±.016" (±400µm)
Measuring force 0.7401gf (7~10mN)
Dimensions (WxDxH) 25 x 16.9 x 24.4" (635mm x 430mm x 620mm)
Mass 209lbs (95kg)
*According to JIS B7451-1997
**Roughness component cutoff value: 2.5mm
***Including a protrusion of 25mm over the turntable rotation center.
D-4
D-05 (2003) full size 12/8/03 3:07 PM Page 1
FORM MEASURING
Roundtest RA-116
Features
• The RA-116 is provided with the innovative
DAT (Digital Adjustment Table) function for
easier centering/leveling of a workpiece.
• Many optional styli are available for a
variety of applications depending on
workpiece shape and measuring purpose.
RA-116
Specifications
Model RA-116
Turntable Rotational accuracy* (2.8 + 0.6H)µinch [(0.07 + 6H/10000)µm]
H = Probing height (inch [mm])
Rotating speed 6rpm
Working diameter ø5.9" (150mm)
Centering range ±.12" (3mm)
Leveling range ±1°
Max. workpiece diameter ø17.32" (440mm)
Max. workpiece weight 44 lbs. (20kg)
Vertical column travel 11.02" (280mm) with a digital scale unit
Horizontal arm travel 6.5" (165mm)**
Air supply Air pressure 4kgf/cm2 (390kPa)
Air consumption 45 liters per minute
Probe and stylus Measuring range ±.04" (±1000µm)
Measuring force 7 to 10gf (70 to 100mN)
Number of measurable cross-sections up to 100
Power consumption 40VA max. (without personal computer)
Dimensions Main unit 24.02 x 14.96 x 24.41" (610 x 380 x 620mm)
(W x D x H) Air filter unit 8.27 x 5.12 x 7.48" (210 x 130 x 190mm)
Mass Main unit 79.2 lbs. (36kg)
Air filter unit 4.4 lbs. (2kg)
* According to JIS B7451-1997 ** Including a protrusion of 1" (25mm) over the turntable rotation center.
D-5
D-06 (2003) full size 12/8/03 3:08 PM Page 1
FORM MEASURING
Roundtest RA-114
Features
• Integration of the measuring unit, display
unit, and printer unit allows easier system
installation and transport. This system is
perfect for use at the shop floor.
• Measurement can be performed by simply
selecting the desired analysis item icon
and pressing the [START] key.
• All analysis items including roundness,
coaxiality, concentricity, and squareness,
etc. are displayed with clear icons.
RA-114
Specifications
Model RA-114
Turntable Rotational accuracy* (2.8 + 0.6H)µinch [(0.07 + 6H/10000)µm]
H = Probing height (inch [mm])
Rotating speed 6rpm
Working diameter ø5.9" (150mm)
Centering range ±.12" (±3mm)
Leveling range ±1°
Max. workpiece diameter ø17.32" (440mm)
Max. workpiece weight 44 lbs. (20kg)
Vertical column Vertical travel 11.02" (280mm)
Max. probing depth 3.94" (100mm) when using a standard stylus
Horizontal arm travel 6.5" (165mm)**
Air supply Air pressure 4kgf/cm2 (390kPa)
Air consumption 45 liters per minute
Probe and stylus Measuring range ±.04" (±1000µm)
Measuring force 7 to 10gf (70 to 100mN)
Full scale range ±.04", ±.02", ±.008", ±.004", ±.002", ±..0008", ±.0004", ±.0002"
(±1000µm, ±500µm, ±200µm, ±100µm, ±50µm, ±20µm, ±10µm, ±5µm)
Number of measurable cross-sections up to 5
Display unit LCD (size: 120 x 90mm)
Printer unit Thermal line printer (built-in)
Power consumption 40VA max. (without personal computer)
Dimensions Main unit 24.02 x 14.96 x 24.41" (610 x 380 x 620mm)
(W x D x H) Air filter unit 8.27 x 5.12 x 7.48" (210 x 130 x 190mm)
Mass Main unit 79.2 lbs. (36kg)
Air filter unit 4.4 lbs. (2kg)
* According to JIS B7451-1997 ** Including a protrusion of 1" (25mm) over the turntable rotation center.
D-6
D-07 (2003) full size 12/8/03 3:09 PM Page 1
FORM MEASURING
ROUNDPAK® V4.0
ROUNDPAK® V4.0 is a Windows®-based software package for the analysis of roundness
and cylindricity, requiring only simple manipulation using a mouse and icons. The great variety
of items available for evaluation allows analysis along numerous geometric deviations.
D-7
D-08 (2003) full size 12/8/03 3:12 PM Page 1
FORM MEASURING
Interchangeable Styli
Order No./Description Tip Dimensions Order No./Description Tip Dimensions
12AAB681 ø1.6mm 12AAB695 ø1mm
4
66
4
2.5
5.5
Stylus for standard Carbide Crank stylus*** Carbide
6.5
66
0.5
2.8
ball (ø1mm) ball 67.5
4
5.5
Stylus for notched Carbide 2X-long type stylus* Carbide
7
146
4
Stylus for groove Sapphire 2X-long type stylus Carbide
66.7 for notched workpiece* ball
7
4
4
Stylus for corner Sapphire 2X-long type stylus Sapphire
66
for groove*
146.3
4
12AAB685 R15mm 12AAB691 RO.25mm
4
21.2 3
66
12AAB674 ø1.6mm 12AAC132 ø1.6mm
226
4
ø1.6 ball stylus Carbide 3X-long type stylus** Carbide 5.5
ball ball
5.5
66
68
12AAB696 ø0.5mm 12AAB676 Mounting 56
9.5
4
5.5
* Vertical use only. ** Vertical use only. In case of RA-2000/H5000, Detector B (996994) should be used. *** Horizontal use only.
D-8
D-09 (2003) full size 12/8/03 3:14 PM Page 1
FORM MEASURING
211-045
350850 12AAB595
12AAB596
Auxiliary workpiece table Optical flat and gage block set Reference hemisphere
• Used for measuring a workpiece whose • Used for checking the probe sensitivity. • Used for checking accuracy.
diameter is 1.6" (40mm) or shorter and • Consists of 10.00mm and 10.02mm • Roundness: 0.08µm
whose height is .8" (20mm) or lower. gage blocks and an optical flat. • Comes with the error compensation data
• Mass: 1.43 lbs. (0.65kg)
356038 997090
211-016
Chucks
Quick chuck Three jaw chuck Micro chuck
• Reversible jaws for external and internal • Reversible jaws for external and internal • Used for clamping extra-small diameter
chucking. chucking. workpieces such as pins or wires.
• Used for centering and clamping a small • Used for centering and clamping a small • External range: Up to .06" (1.5mm)
diameter workpiece. diameter workpiece such as crank shafts • Mounting flange: Ø4.65" (118mm)
• Easy clamping with a knurled clamp ring. or pins. • Height: 1.91" (48.5mm)
• External range: .04" to 2.95" (1 to 75mm) • Heavy-duty type • Mass: 1.36 lbs. (620g)
• Internal range: .55" to 2.75" (14 to 70mm) • With a clamping wrench.
• Mounting flange: Ø4.65" (118mm) • External range: .04" to 3.34" (1 to 85mm)
• Height: 1.34" (34mm) • Internal range: 1.3" to 3.34" (33 to 85mm)
• Mass: 2.64 lbs. (1.2kg) • Mounting flange: Ø6.18" (157mm)
• Height: 2.99" (76mm)
211-032 • Mass: 8.36 lbs. (3.8kg)
211-014 211-031
D-9
D-10 (2003) full size 12/8/03 3:04 PM Page 1
FORM MEASURING
4.06" (103)
2.01" (51)
7.20" (183)
6.69" (170)
5.16" (131)
10.35" (263)
9.84" (250)
.67" (17)
8.31" (211)
12AAB597
D-10
E-01 (2003) full size 12/11/03 3:54 PM Page 1
Vision Systems
Quick Scope - QS200, QS200Z, QS250, QS250Z E-2
VISION SYSTEMS
QS Excellent Performance-cost
Ratio CNC System QS200Z
Features
• Surface, contour and fiber-optic ring light illumination
options allow users to configure the QS lighting to meet a
variety of measurement needs.
• Powerful, Windows® based QSPAK software is easy to
use and offers a wide spectrum of measuring and
analysis capabilities.
• Functions include zoom, auto-focus, measurement
playback, one-click edge detection, graphic display,
48 different macros, and a pattern matching function for
several common part features.
• X,Y stage can be controlled by mouse or through the
optional multi-function control box.
Specifications
QS200Z QS250Z
Model No. QS200 QS250
Range X-axis 8" (200mm) 8" (200mm)
Y-axis 8" (200mm) 10" (250mm)
Z-axis 4" (100mm) 4" (100mm)
Resolution 0.0005mm
Length standard Reflective linear encoder
Measuring accuracy (at 20°C) (3+10L/1000)µm
Machine operation CNC/manual (motor-driven)
Maximum drive speed: 50mm/s
Maximum acceleration: 250mm/s2
Auto-focus function Provided as standard
Magnification on QS200Z/250Z: 21X - 147X (8-step zoom)
17" monitor QS200/250: 42X† / 105X†† / 210X†††
(Select either the power-zoom lens type
†
when using 1X objective (02ALA400)
or the fixed-magnification type.) ††
when using 2.5X objective (02ALA410)
†††
when using 5X objective (02ALA420)
Image detecting unit High-resolution 1/3" color CCD camera
Illuminations Surface Co-axial light, fiber-optic ring light
Contour Stage light
Table glass size 10.59" x 10.28" 10.59" x 12.24"
(269 x 261mm) (269 x 311mm)
Maximum workpiece height 4.33" (110mm)
Maximum workpiece weight 22 lbs. (10kg)
Power supply 100V - 120V AC
Power consumption 1300VA at max.
Dimensions (W x D x H)
Main unit 18.31" x 32.09" x 25.39" (465 x 815 x 645mm)
Mass Main unit 165 lbs. (75kg)
*When using 2.5X objective or the zoom lens in 2.5X magnification (Magnification on monitor: 105X), L= Measuring length (mm)
E-2
E-03 (2003) full size 12/8/03 3:39 PM Page 1
VISION SYSTEMS
Quick Scope
Features
• The most affordable Quick Scope model. QS-E1020
• 0.1µm resolution and 6" (150mm) Z-axis range.
• Magnification can be adjusted by changing objectives.
• Excellent observation/measurement for a single
workpiece.
• The quick release system in the stage allows instant
switching between a coarse movement and a fine
movement.
• An optional fiber-optic ring light is available.
• Graphic and Navigation functions allow for quick
maneuvering around the workpiece.
• Part programs are easily created in the Windows® based
QSPAK software.
Specifications
Model No. QS-E1020
Range X-axis 8" (200mm)
Y-axis 4" (100mm)
Z-axis 6" (150mm)
Resolution 0.0001mm
Length standard Reflective linear encoder
Measuring accuracy (at 20°C) (3+20L/1000)µm
Machine operation Manual
Auto-focus function Not available
Magnification on 17" monitor 42X† / 105X†† / 210X†††
†
when using 1X objective (02ALA400)
††
when using 2.5X objective (02ALA410)
†††
when using 5X objective (02ALA420)
Image detecting unit High-resolution 1/3" color CCD camera
Illuminations Surface Co-axial light
Contour Stage light
Table glass size 9.44" x 5.51" (240 x 140mm)
Maximum workpiece height 5.50" (150mm)
Maximum workpiece weight 22 lbs. (10kg)
Power supply 100V - 120V AC ±10%
Power consumption 160VA at max.
Dimensions (W x D x H) 24.33" x 29.60" x 26.85" (618 x 752 x 682mm)
Mass 126 lbs. (57kg)
E-3
E-04 (2003) full size 12/8/03 3:40 PM Page 1
VISION SYSTEMS
Quick Scope
Dimensions
25.39" (645mm)
26.60" (662mm)
25.20" (640mm)
26.85" (682mm)
(160mm)
6.30"
0.79" (20mm)
.63" (16mm) 3.70" 13.78" (350mm) 6.85" 8.82" (224mm) 13.27" (337mm) 5.35"
(94mm) (174mm) 2.17" (55mm) (136mm)
18.31" (465mm) 32.09" (815mm) 24.33" (618mm) 29.61" (752mm)
System Diagram
QS CNC Series
Quick Scope Main Unit
QSPAK
High-resolution Contour Illumination
Personal Computer Color CCD Camera (Stage Light)
(Keyboard, mouse,
17-inch display, printer)
Surface Illumination Foot Switch
QS200Z/250Z (Coaxial Light) (937179T)
Programmable
Calibration Glass Chart Power Zoom Lens
(02AKN020) (0.5X - 3.5X) Fiber-optic Ring Light Joystick Box
(960707)
QS200/250
Objectives
1X (02ALA400) 1X Tube Lens QS Controller Unit
2.5X (02ALA410) (Light Source Unit) Control Box
5X (02ALA420) (02APA900)
E-4
E-05 (2003) full size 12/8/03 3:43 PM Page 1
VISION SYSTEMS
Quick Image
Telecentric Lens Utilized 2D
Vision measuring instrument Fixed stage type
Features
• A telecentric optical system is adopted. Due to a long
depth of focus, workpieces which have thickness or
stepped faces such as sleeves and cutting tools can be
measured easily without focusing.
• Two modes are available as standard: A normal and
a high resolution mode.
• Equipped with a mega-pixel CCD camera.
• Batch measurement of a wide field of view X-Y stage type
(1.16 x 0.87" / 29.5 x 22.2mm) can be performed quickly
with a unique software, QSPAK.
• A variety of illumination systems are available.
Specifications
Model No. QI QI-RL QI-50 QI-50RL
Order No. 361-801A 361-802A 361-803A 361-804A
Type Fixed stage type X-Y stage type
Field of view 1.16 x 0.87" (29.5 x 22.2mm)
Measuring mode (selectable) Normal mode / High resolution mode
Travel range X-Y axis – 2 x 2" (50 x 50mm)
Z-axis 1" (25mm)
Depth focus Normal mode 0.87" (22mm)
High resolution mode 0.05" (1.2mm)
Repeatability Normal mode ±2s ≤118µ" (3µm)
on monitor High resolution mode ±2s ≤39.4µ" (1µm)
Camera Mega-pixel CCD camera (B&W)
Illumination Standard Transmitted illumination
unit Optional Co-axial light / 4 quadrants white LED ring light
Note: Quick Image requires a computer system (not included)
54SAA561 Laptop Computer
54SAA560 Desktop Computer
54SAA559 QIPak Software
E-5
E-06 (2003) full size 12/8/03 3:50 PM Page 1
VISION SYSTEMS
Quick Image
Dimensions
E-6
E-07 (2003) full size 12/8/03 3:51 PM Page 1
VISION SYSTEMS
Applicable Models
E-7
E-08 (2003) full size 12/8/03 3:52 PM Page 1
VISION SYSTEMS
E-8
E-09 (2003) full size 12/8/03 3:53 PM Page 1
VISION SYSTEMS
E-9
E-10 (2003) full size 12/8/03 3:25 PM Page 1
VISION SYSTEMS
Specifications: Quick Vision Accel/ Quick Vision Hybrid Accel 404 / 606 / 808
Model No. QVA404 / QVHA404 QVA606 / QVHA606 QVA808 / QVHA808
Measuring Range X-axis 16" (400mm) / 11" (276mm) 24" (600mm) / 19" (476mm)* 32" (800mm) / 27" (676mm)*
Y-axis 16" (400mm) 26" (650mm) 32" (800mm)
Z-axis 6" (150mm) 6" (150mm) 6" (150mm)
Resolution Normal 0.0001mm
Super 0.0001mm
Length standard Reflective linear encoder
Measuring accuracy Normal U1xy = (2.2 + 3L/1000)µm, U1z = (4 + 5L/1000)µm, U1z = (3.5 + 5L/1000)µm*
(at 20°C) Super U1xy = (1.5 + 3L/1000)µm, U1z = (3 + 4L/1000)µm, U1z = (2.5 + 4L/1000)µm*, U2xy = (2.5 + 4L/1000)µm
Max.drive speed Normal 400mm/s
Super 200mm/s
Tube lens PRO, PRO-III 1x / 2x / 6x (power turret)
Objectives PRO, PRO-III 1x / 2.5x / 5x
Magnification on 17" monitor Using 1x objective: 32x / 64x / 192x (power turret)
Sensor unit PRO High resolution B&W CCD camera, Laser probe with 1.5µm laser spot (Quick Vision Hybrid Accel)
PRO-III High resolution Color CCD camera, Laser probe with 1.5µm laser spot (Quick Vision Hybrid Accel)
Illumination system Surface Coaxial light and 4-quadrant PRL system (PRO: RGB LED, PRO III: halogen)
Contour Stage light (PRO: RGB LED, PRO III: halogen)
Table glass size 19.41" x 21.69" (493 x 551mm) 27.44" x 29.84" (697 x 758mm) 34.76" x 37.71" (883 x 958mm)
Workpiece load Normal 22 lbs. (10kg)
Super 22 lbs. (10kg)
Power supply 100-120VAC±10%, 50/60Hz
Power consumption 2000W max.
* Using laser sensor (Quick Vision Hybrid Accel)
E-10
E-11 (2003) full size 12/8/03 3:37 PM Page 1
VISION SYSTEMS
Optional Software:
EASYPAG CAD Option
Off-Line Part Programming with 2-D CAD Data CAD Data Transfer Program
EASYPAG allows off-line part programming for QVPak by using CAD Import allows data to be imported from the CAD
a two-dimensional CAD data (in IGES or DXF format). system. The workpiece CAD data in IGES or DXF format
can be imported into QVPak and displayed on the graphic
window. This ensures dramatic time reduction in part
programming and joystick operation.
CAD data
imported
PAGPAK FORMPAK-QV
Off-Line Part Programming with CAD/NC Data 2-D data-processing program
PAGPAK automatically generates a part program based on 2D FORMPAK-QV performs two-dimensional contour analysis
CAD data (in IGES, DXF or GERBER format) or NC processing based on measurement data collected by Quick Vision,
data, for measuring discontinuous through-holes in printed comparing that data with nominal values.
circuit boards.
Graphic indication of
measurement result
Analysis
Measurement
(automatic scanning) Tolerancing
Distribution chart of
measurement result
E-11
E-12 (2003) full size 12/8/03 3:38 PM Page 1
VISION SYSTEMS
QVPartManager
Part Program Management
QVPartManager is an optional software package that allows
multiple workpieces arranged on the stage to be measured
at once using a part program.
Measurement screen
GO/NG list
QVTraceMaker QV-GRAPH
Laser Probe Scanning Path Generation 3-D graph generation program
QVTraceMaker generates a scanning path for the laser probe QV-GRAPH uses the graphing functions of MS-Excel® as a
(Quick Vision Hybrid) by capturing a workpiece image. basis for the three-dimensional graphic representation of
coordinate data obtained by the laser probe (Quick Vision
Hybrid). In addition to providing three-dimensional represen-
tations of bar graphs, contour lines and wire frames, the
program enables the verification of numerical data on the
MS-Excel® worksheet.
MSHAPE-QV
3-D form-evaluation program
MSHAPE-QV visually expresses surface contour based on
3-D wire frame
the coordinate data acquired by the laser probe (Quick
Vision Hybrid) and analyzes curved profiles. Contour lines,
fill areas, etc. can be displayed.
E-12
E-13 (2003) full size 12/8/03 3:39 PM Page 1
VISION SYSTEMS
QSPak
Features
• QSPAK operates in a Windows® based operating system
for easy operation with on-screen dialog.
• All operations can be performed on-screen for maximum
operator efficiency: measuring, workstage drive, zoom
control, illumination, data processing, and printing.
• Macros include one-click edge detection for fast distance
and angle calculation, and circle measurement—just by
clicking on the icon and then the feature on the screen.
• Easy X,Y table navigation function provides on-screen
instructions for automatic measurement or repeat
measurements.
• Template matching and manual pattern matching functions
allow for comparison to many common part forms.
• Bit-map image storage capability.
For observation/comparison of a form For repeated measurement/auto-measurement
• Template matching function • Stage navigation function (QS)
• Manual pattern matching function • Quick navigation function (QS-E)
For simple measurement • Playback function
• One-click edge detection tool function • Graphic function
• Smart tool function • External data output function
• User macro function • Statistical calculation function
E-13
E-14 (2003) full size 12/8/03 3:40 PM Page 1
VISION SYSTEMS
System configuration
359-653A Ball Endmill measuring unit
• Digital rotary head
• Ball endmill measurement software
• EF-11PR Counter Vision Unit (6A)
Measuring microscope
(MF-A1010)
E-14
F-01 (2003) full size 12/11/03 3:53 PM Page 1
Measuring Instruments
(Optical Instruments)
MEASURING INSTRUMENTS
Tube Selection
Features
• Bright field observation, clear and flare lens erect image, wide • Focus and measure using the fine/coarse movement handle
field of view. with the large-size grips on both sides of the column.
• Long working distance objectives, up to 100x magnification • Built in X- and Y-axis Zero-set switches (Z-axis has a non-
(total: 2000x). built-in Zero set switch).
• Aperture diaphragms in the transmitted illumination and • Available with the Vision Unit for upgrading to a vision mea-
reflected illumination system are standard features. suring system.
• The quick-release stage system, which is especially useful in
long-stroke measurements.
Specifications
Binocular Unit with XY Counter MF-A505 176-531PB MF-A1010 176-532PB MF-A1720 176-533PB MF-A1730 176-534PB
Monocular Unit with XY Counter MF-A505 176-531PM MF-A1010 176-532PM MF-A1720 176-533PM MF-A1730 176-534PM
Binocular Unit with XYZ Counter MF-A505H 176-535PB MF-A1010H 176-536PB MF-A1720H 176-537PB MF-A1730H 176-538PB
Monocular Unit with XYZ Counter MF-A505H 176-535PM MF-A1010H 176-536PM MF-A1720H 176-537PM MF-A1730H 176-538PM
Optical Tube Choice between Monocular and Binocular tube (depression angle: 25°),Reticle projection method,
with TV mount, Optical path ratio (eyepiece/CCD camera: 50/50 fixed)
Image Erect image
Eyepiece lens (optional) 10x (field no.:24), 15x (field no.:16), 20x (field no.:12)
Objective 1x, 3x*, 5x, 10x, 20x, 50x, 100x, *Standard accessory
Focusing Max. workpiece height 6" (150mm) 9" (220mm)
Method Manual focusing (course focusing: 30mm/rev., fine focusing: 0.2 mm/rev.)
Illumination Reflected Telecentric illumination with adjustable aperture diaphragm, 12V/50W halogen lamp (non-stepped brightness adjustment)
Transmitted Koehler illumination with adjustable aperture diaphragm, 12V/50W halogen lamp (non-stepped brightness adjustment)
Microstage XY travel range 2"x2" (50x50mm) 4"x4" (100x100mm) 8"x7" (200x170mm) 12"x7" (300x170mm)
Table top dimensions 11.02"x11.02" (280x280mm) 11.02"x11.02" (280x280mm) 16.14"x13.46" (410x342mm) 20.07"x13.46" (510x342mm)
Effective glass size 6.69"x6.69" (170x170mm) 6.69"x6.69" (170x170mm) 10.23"x9.05" (260x230mm) 14.17"x9.05" (360x230mm)
Swiveling — — ±5° (left) ±5° (left)
Max workpiece weight 11 lbs. (5kg) 11 lbs. (5kg) 44 lbs. (20kg) 44 lbs. (20kg)
Quick release mechanism X and y Axis
Zero Switch X and Y Axis (Z Axis:MF-A505H/MF-A1010H/MF-A1720H/MF-A1730H)
Length Standard Linear encoder (Linear scale) • Patent registered (Japan)
Digital Counter Resolution .0001"/.00005"/.00001 (0.001mm/0.0005mm/0.0001mm) switchable
No. of axis 2-axis (3-axis: MF-A505H/MF-A1010H/MF-A1720H/MF-A1730H)
Functions Zero setting, Resolution switching, Counting direction switching, Data output via RS-232C
Measuring Accuracy** (at 20°C) (3+0.02L)µm conforming to JIS B 7153, L = Measuring length (mm)
Power supply 120VAC, 50/60Hz, 160W
Mass Approx. 121 lbs. (55kg) Approx. 121 lbs. (55kg) Approx. 286 lbs. (130kg) Approx. 303 lbs. (138kg)
**Not including the Z-axis measuring accuracy
F-2
F-03 (2003) full size 12/8/03 7:53 PM Page 1
MEASURING INSTRUMENTS
F-3
F-04 (2003) full size 12/8/03 7:54 PM Page 1
MEASURING INSTRUMENTS
Vision Unit
Series 359
3.94" (100) 2.05" (52)
Unit: inch (mm)
1.26" (32)
Vision Unit
3.62" (92)
CCD
8.27" (210)
Camera Unit
Adapter Unit
Ø1.77" (45)
: Optional accessory
The computer system and Vision Unit
microscope are optional. Calibration glass
chart (02AKN020) CCD QSPAK
camera unit
Features
5X objective Laser printer
• Clear and sharp images with the color CCD camera.
• Increased performance-cost ratio.
• The Navigation function and Graphic window allow easy 10X objective Suffix: A for 100V, C for 110V, D for
220V, E for 240V or non for 100V
operation and measurement.
• Single-click Edge-detection and macro icon tools enhance
measurement efficiency. Ball Endmill
Measurement Unit
• Wide field of view due to the 0.5X camera adapter. (See page E-14)
• Ability to store images.
• Data output of measurement results.
F-4
F-04 (2003) full size 12/8/03 7:54 PM Page 1
MEASURING INSTRUMENTS
Vision Unit
Series 359
3.94" (100) 2.05" (52)
Unit: inch (mm)
1.26" (32)
Vision Unit
3.62" (92)
CCD
8.27" (210)
Camera Unit
Adapter Unit
Ø1.77" (45)
: Optional accessory
The computer system and Vision Unit
microscope are optional. Calibration glass
chart (02AKN020) CCD QSPAK
camera unit
Features
5X objective Laser printer
• Clear and sharp images with the color CCD camera.
• Increased performance-cost ratio.
• The Navigation function and Graphic window allow easy 10X objective Suffix: A for 100V, C for 110V, D for
220V, E for 240V or non for 100V
operation and measurement.
• Single-click Edge-detection and macro icon tools enhance
measurement efficiency. Ball Endmill
Measurement Unit
• Wide field of view due to the 0.5X camera adapter. (See page E-14)
• Ability to store images.
• Data output of measurement results.
F-4
F-05 (2003) full size 12/8/03 7:55 PM Page 1
MEASURING INSTRUMENTS
Specifications
BRIGHT FIELD MF-UA505TH MF-UA1010TH MF-UA1720TH MF-UA1730TH
OBSERVATION TYPE 176-551A 176-552A 176-553A 176-554A
BRIGHT/DARK FIELD MF-UA505THD MF-UA1010THD MF-UA1720THD MF-UA1730THD
OBSERVATION TYPE 176-555A 176-556A 176-557A 176-558A
Optical tube Sidentopf type, Pupil distance adjustment (51 to 76mm), 1X tube lens, Binocular eyepiece (depression
• Patent pending (Japan) angle 20°), Reticle projection method, with TV mount, optical pass ratio (eyepiece/CCD camera: 50/50 fixed)
Image Erect image
Eyepiece lens 10x* (field No.: 24), 15x (field No.: 16), 20x (field No.: 12), *Standard accessory
Applicable objective Bright Field M Plan Apo, M Plan Apo SL, G Plan Apo
(optional) Bright/Dark Field BD Plan Apo, BD Plan Apo SL
Applicable revolver Bright Field Manual BF revolver 378-018, Power BF revolver 378-016A
(optional) Bright/Dark Field Manual BF/DF revolver 176-211, Power BF/DF revolver 176-210A
Focusing Max. workpiece height 6" (150mm) 9" (220mm)
Method Manual focusing (coarse focusing: 10mm/rev., fine focusing: 0.25mm/rev,)
Illumination Reflection illumination Telecentric illumination with adjustable aperture diaphragm, 12V/50W halogen lamp (non-stepped brightness adjustment)
Transmitted illumination Koehler illumination with adjustable aperture diaphragm, 12V/100W halogen lamp (non-stepped brightness adjustment)
Workstage XY travel range 2"x2" (50x50mm) 4"x4" (100x100mm) 8"x7" (200x170mm) 12"x7" (300x170mm)
Table top dimensions 11.02"x11.02" 11.02"x11.02" 16.14"x13.46" 20.07"x13.46"
(280x280mm) (280x280mm) (410x342mm) (510x342mm)
Effective glass size 6.69"x6.69" 6.69"x6.69" 10.23"x9.05" 14.17"x9.05"
(170x170mm) (170x170mm) (260x230mm) (360x230mm)
Swiveling – – ±5° (left) ±5°(left)
Max. workpiece weight 11 lbs. (5kg) 11 lbs. (5kg) 44 lbs. (20kg) 44 lbs. (20kg)
Quick release mechanism X and Y axis
Zero switch X, Y and Z axis (Z axis THD type only)
Length standard Linear encoder (Linear Scale) •Patent registered (Japan)
Digital Resolution .0001"/.00005"/.00001" (0.001mm/0.0005mm/0.0001mm) switchable
Counter No. of axis 2-axis TH type, 3-axis THD type
Functions Zero-setting, Resolution switching, Counting direction switching, Data output via RS-232C
Measuring accuracy** (at 20°C) (3+0.02L)µm conforming to JIS B 7153, L=Measuring length (mm)
Power supply 120VAC, 50/60Hz, 160W
Mass Approx. 121 lbs. (55kg) Approx. 121 lbs. (55kg) Approx. 286 lbs. (130kg) Approx. 303 lbs. (138kg)
**Not including the z-axis measuring accuracy.
F-5
F-06 (2003) full size 12/8/03 7:55 PM Page 1
MEASURING INSTRUMENTS
F-6
F-07 (2003) full size 12/8/03 7:57 PM Page 1
MEASURING INSTRUMENTS
FS-70Z-S
with optional
Features stand, stage
• Mitutoyo Infinity Corrected Optics and lenses.
• Extra Long Working Distance Plan Apochromat Objectives
• Laser Cutting Objectives
Specifications
Model No. FS70Z-S FS70Z-THS FS70L-S FS70L-THS FS70L4-S FS70L4-THS
Order No. 378-185-2 378-185-4 378-186-2 378-186-4 378-187-2 378-187-4
Focus adjustment With concentric coarse and fine focusing wheels (right and left)
(1.97" (50mm) travel range, 0.1mm/rev. for fine adjustment, .15" (3.8mm)/rev. for coarse adjustment)
Trinocular tube
Image Erect image
Pupil distance Siedentopf type, adjustment range: 2.01" - 2.99" (51 - 76mm)
Field number 24
Optical pass ratio Fixed (eyepiece/ Switchable (eyepiece/laser=100/0 or 0/100)
CCD camera=50/50)
Protective filter – Built-in laser beam filter
Main unit
Tube lens 1x - 2x zoom (visible radiation) 1x (near-infrared - visible - 1x (visible and
(correction) near-ultraviolet radiation) ultraviolet radiation)
Applicable laser – 1064/532/355nm YAG laser 532/266nm YAG laser
Camera mount Camera Mount accepts either 1x C-mount Video Adapter B or for 0.5x Camera Mount with Green Filter Switch
(Dove Tail Type: Part of magnification use both 1x AND 0.5x C-mount Video Adapters. accepts either 1x C-mount Video Adapter
Trinocular Tube) B or for 0.5x magnification use both 1x
and 0.5x C-mount Adapters
Illumination system Reflective illumination for bright field (Koehler illumination, with aperture diaphragm)
Light source 21V, 150W Fiber Optic Light Source: AC 100, 120, 220 and 240 VAC@50/60Hz
Nosepiece Revolving nosepiece, rotary type for bright field lens (with 4 mounts), detachable
Objectives (optional)
For observation M Plan Apo -3 , M Plan Apo SL, G Plan Apo
For laser-cutting – M/LCD Plan NIR -4, M/LCD Plan NUV -4 M Plan UV
Loading weight on
optical tube -5 Approx. 29.70 lbs (13.5kg)
Mass 14.5 lbs (6.6 kg) 16.5 lbs (7.5 kg) 14.1 lbs (6.4 kg) 15.8 lbs (7.2 kg) 14.7 lbs (6.7 kg) 16.5 lbs (7.5 kg)
-1: When using the FS70L or -L4 with a laser system, refer to “Cautions in using microscope with YAG laser system”.
-2: Optional -3: M Plan Apo 1x should be used together with the polarizer (378-092).
-4: Select model depending on the type of laser wavelength. -5: Weight of objective lenses and eyepieces not included.
F-7
F-08 (2003) full size 12/8/03 7:58 PM Page 1
MEASURING INSTRUMENTS
F-8
F-09 (2003) full size 12/8/03 7:59 PM Page 1
MEASURING INSTRUMENTS
F-9
F-10 (2003) full size 12/8/03 8:00 PM Page 1
MEASURING INSTRUMENTS
F-10
F-11 (2003) full size 12/8/03 8:00 PM Page 1
MEASURING INSTRUMENTS
VM Zoom 40
Series 378
Features
This advanced VIDEO MICROSCOPE Unit with large zoom
ratio optical system can be installed in Analytical Probe
Stations, YAG Laser Cutting equipment and all kinds of analy-
sis instruments.
• High Quality Image:
Combining New M Plan Apo HR10x objective for standard
attachment.
• Easy to operate:
Observation from the low magnification to the high
magnification with zoom optical system of 40:1 ratio.
Available to process the various workpiece by Laser
Cutting through the optical system which corresponds to
YAG Laser with 3 wavelength.
F-11
F-12 (2003) full size 12/8/03 8:01 PM Page 1
MEASURING INSTRUMENTS
VM Zoom 40
Series 378
System Configuration
Standard Specifications
*1: For VMZ40M-BL *2: For VMZ40R-B, VMZ40R-BL *4: For VMZ40R-BL4
*3: For VMZ40R-L, VMZ40R-BL
Option
F-12
F-13 (2003) full size 12/8/03 8:01 PM Page 1
MEASURING INSTRUMENTS
VM Zoom 40
Series 378
Dimensions
VMZ40R-BL : 378-178A
267.4 111.5 Vertical travel
25
100 42.5
22 C-mount Intermediate
Optical path image position
25
switch
17.5
Binocular
Laser mask eyepiece
position VM ZOOM
40
Eye point
WF
ZOOM
JAPAN
78
30º
459
Laser mount
Laser port
351.4
145
Nosepiece knob
(standard accessory)
10
(Parfocal length)
45
80.6
95
100 42.5
25 25
Intermediate C-mount
22 Intermediate
image position With the filter switch image position
Optical path switch
L=2000
250
109
60
VM Z M Remote Controller
142.5
ILLUMINATION
PRESET
MAGNIFICATION
PRESET 1 2 3 4 5
JOG SHUTTLE POWER
ZOOM LINE IN
362
Weight: Approx. 7kg
(Remote controller and jog-shuttle dial combined)
F-13
F-14 (2003) full size 12/8/03 8:02 PM Page 1
MEASURING INSTRUMENTS
Features
• Small, lightweight microscope unit with a high performance-cost
ratio. This unit is used as an integrated part of an inspection
system.
• For a wide range of laser applications, such as laser-cutting
fine-films of semiconductors and of liquid crystal substrates. The
optical systems of the VMU support ranges of laser wavelengths:
the VMU-L supports standard waves (1064nm: near-infrared),
Class 2 higher harmonics (532nm: visible) and Class 3 higher 378-505
harmonics (355nm: near-ultraviolet) YAG lasers; the VMU-L4
supports Class 2 and Class 4 higher-harmonics (266nm:
ultraviolet) YAG lasers. However, Mitutoyo assumes no
responsibility whatsoever for the performance and/or safety of with optional
the laser system used with Mitutoyo microscopes. A careful
examination is recommended in selecting a laser emission unit. Objective Lens.
• Various optional accessories are available for various
combinations:
Revolver for 4 objectives for bright field observation, C-mount
adapter unit (0.5x/2x), Polarizer, etc.
The Telecentric illumination unit with aperture diaphragm is ideal
for a image processing that requires a depolarized illumination.
F-14
F-15 (2003) full size 12/8/03 8:03 PM Page 1
MEASURING INSTRUMENTS
Monitor system
Stand
0.5x TV adapter unit 2x TV adapt unit (378-731)
(378-704) (378-703) P.19
Polarizer*1
(378-710)
Revolver for bright field*2
Illuminator of remote (989-103) M Plan Apo series
(378-707) For inspection
Light Guide, 7Ft. 90°Angle (50AAB310)
G Plan Apo series
Light Guide, 7Ft. (50AAB175) For inspection
M/LCD Plan NIR series (for VMU-L)
For use with 1064/532nm laser system
*1 Use Polarizer (378-710) in combination with telecentric illumination unit (378-709). M/LCD Plan NUV series (for VMU-L)
For use with 532/355nm laser system
*2 Focus unit A (378-705) can be mounted on the stand (378-731)
M Plan UV series (for VMU-L4)
Use focus unit A (378-705) when using the revolver for bright field (378-707). For use with 532/266nm laser system
*3 Use Focus unit B (378-706) when a shorter mounting distance is desired.
Intermediate Ø56
image position
C-mount
Ø45
17.5
50 47
Fiber mounting
Position
59
27
213.4
27 27
308.4
106
41.5 27
20.5
76
(parfocal length)
FS objective
(optional)
95
Ø43
F-15
F-16 (2003) full size 12/8/03 8:03 PM Page 1
MEASURING INSTRUMENTS
Eyepiece Specifications
Order No. Magni- Field Mass Individual
Series 378 fication No. No.
378-856 10X 24 85g 378-856-5
378-857 15X 16 40g 378-857-5
378-858 20X 12 55g 378-858-5
Reticles (Optional)
Order No. Description
516848 Cross-hair
516576 Broken cross-hair (90° and 60°)
516578 Concentric circle (Diametric increment: 1.2mm)
516577 20mm scale (Minimum reading: 0.1mm) with cross-hair
516849 10mm scale (minimum reading: 0.1mm)
Features 516850 5mm scale (Minimum reading: 0.05mm)
516851 10x10mm section (Minimum section: 1x1mm)
• The field of view is extra wide.
• Optional reticles are available.
Features
Objectives • The long working distance type FS ULWD Objectives pro-
vides a wide space between the lens surface and the
Series 378 workpiece surface in focus, making it possible to observe
workpieces which are hard-to-focus.
• The metallurgical plan aprochromatic (M Plan Apo) objec-
tive is an excellent optical system. This objective provides
a flat, chromatic aberration free image with little color
aberration throughout the field of view, making it suitable
for any type of microscope.
• Specially designed objectives are also available with cor-
rection for near-infrared radiation, near-ultraviolet radia-
tion, and ultra-violet radiation, or various thickness of
LCD screen glasses.
• The mounting screw threads of objectives are designed
to conform to JIS B-7141-1988.
F-16
F-17 (2003) full size 12/8/03 8:04 PM Page 1
MEASURING INSTRUMENTS
Objectives
Series 378
Near-ultraviolet Radiation Corrected M Plan NUV Series Near-infrared Radiation Corrected M Plan NIR Series for
for Bright Field Observation Bright Field Observation
Near-ultraviolet Radiation Corrected Near-Infrared Radiation Corrected
M Plan NUV Series for Bright Field Observation M Plan NIR Series for Bright Field Observation
Order No. Magni- Numerical Working Order No. Magni- Numerical Working
fication aperture distance fication aperture distance
(N.A.) (W.D.) (N.A.) (W.D.)
378-817 20X 0.40 17.0mm 378-822 5X 0.14 37.5mm
378-818 50X 0.42 15.0mm 378-823 10X 0.26 30.5mm
378-819 100X 0.50 11.0mm 378-824-1 20X 0.40 20.0mm
378-825-1 50X 0.42 17.0mm
378-826 100X 0.50 12.0mm
F-17
F-18 (2003) full size 12/8/03 8:05 PM Page 1
MEASURING INSTRUMENTS
Objectives
Series 378
BD Plan Apo Series for Bright/Dark Field Observation
Order No. Magni- Numerial Working
fication aperture distance
(N.A.) (W.D.)
378-831 2X 0.055 34.0mm
378-832 5X 0.14 34.0mm
378-833 10X 0.28 33.5mm
378-834 20X 0.42 20.0mm
378-835 50X 0.55 13.0mm
378-836 100X 0.70 6.0mm
Order No.
378-080 for 5x and 10x objectives
378-079 for 20x objectives
378-078 for 50x and SL20x objectives
378-076 for 100x, SL80x and SL50x objectives
F-18
F-19 (2003) full size 12/8/03 8:06 PM Page 1
MEASURING INSTRUMENTS
Toolmaker’s Microscope
with Camera System
with Monitor.
TM-505 64AAA961
Specifications
Optical tube • Monocular at 30° angle
• Broken-cross-hair reticle (176-126)
• Erect image
• Diopter adjustable
Eyepiece protractor • Graduation: 1°
• Protractor range: 360°
• Angle reading: 6' vernier
Eyepiece • Magnification: 15X
• Field Number: 13mm
Objective • Magnification: 2X
• Working distance: 2.638" (67mm)
• Numerical aperture: 0.07
Total magnification • 30X
Transmitted • Light source: Halogen bulb (24V, 2W)(383038)
illumination • GIF filter
• Adjustable light intensity
Reflected • Oblique single-bulb illumination (64AAA968)
illumination • Optional twin-bulb illumination (176-203)
• Light source: Halogen bulb (24V, 2W)(383038)
• Adjustable light intensity
Power supply • 100/110/120/220/240V AC, 50/60Hz
Power consumption • 100 VA
F-19
F-20 (2003) full size 12/8/03 8:07 PM Page 1
MEASURING INSTRUMENTS
F-20
F-21 (2003) full size 12/8/03 8:08 PM Page 1
MEASURING INSTRUMENTS
TM-505/510
Toolmaker’s Microscopes:
Series 176
176-109 Metric coarse thread (P=0.25 - 1.0) 176-128 NF thread (24 - 14 TPI), inch
176-110 Metric coarse thread (P=1.25 - 2.0) 176-129 NF thread (13 -10 TPI), inch
176-140 ISO metric coarse thread (P=0.075 - 0.7) 176-130 Involute gear tooth, m=0.1 - 1.0
176-141 ISO metric coarse thread (P=0.75 - 2) (Pressure angle: 14.5°, normal rack)
176-142 ISO unified thread (80 - 28 TPI) 176-112 Involute gear tooth, m=0.1 - 1.0
176-143 ISO unified thread (24 - 14 TPI) (Pressure angle: 20°, normal rack)
176-144 ISO unified thread (13 - 10 TPI) 176-111 Concentric circle
176-123 Unified screw thread (80 - 28 TPI) (Up to ø4mm, 0.05mm increment)
176-124 Unified screw thread (24 - 14 TPI) 176-135 Concentric circle
176-125 Unified screw thread (13 - 10 TPI) (Up to ø.2", .01" increment)
176-120 Whitworth thread (60 - 26 TPI) 176-113 55° angle
176-121 Whitworth thread (24 - 18 TPI) 176-114 60° angle
176-122 Whitworth thread (16 - 11 TPI) 176-126 90° broken cross-hair*
176-127 NF thread (80 - 28 TPI), inch * Standard accessory
0.25 0.075
1.25 0.75 80
0.08 24
0.3 13
0.09 72
0.8
0.1
0.35 1.5 64
0.125 20
1 12
0.15 56
0.4
0.175
0.45 1.75 0.2 1.25 48
18 11
0.225
44
0.5 0.25 1.5
0.3 40
2.0 16 10
0.6 0.35 1.75
0.4 36
0.75
0.45
2 32
0.5 14
0.9
0.6 28
1.0 0.7
64 22 64
20
40 14
12 56
56
36 48
48 18 20
11 12
32 44
44
16 40
40
30 19
10 11 36
36
28
14 32
32
18
26 28
28
13 0.25 0.3
.1 0
.1 8 0
.2
.1 7 0
0.3 0.4
.1 6 0
20
.1 5 0
0.4 0.5
.1 4 0
.1 3 0
0.5 0.6
.1 2 0
.1 1 0
12 0.8
.0 0 0
0.6
.0 9 0
1.0
.0 8 0
0.8
.0 7 0
18
.0 60 0
1.0
.0 4 0
.0 5
.0 3 0
.0 20 0
11
10
16
10
14
176-114 176-126
F-21
F-22 (2003) full size 12/8/03 8:08 PM Page 1
MEASURING INSTRUMENTS
Stereo Microscope
MSM-414L/MSM-414TL
Series 377
Features
• Continuous 1X - 4X magnification
• Image always in focus throughout zoom range
• Crisp, erect images with high resolution and excellent
stereoscopic effect
• Stereo-tube can be rotated a full 360°, for viewing at any angle
• Bilateral zoom control knob adds convenience and increases
operator efficiency
• Diopter adjustment for both eyepieces
• Binocular Tube Inclination: 45°
• Focusing Range: 1.46" (37mm) 377-972A
• Interpupillary Adjustable Range: 2.12" - 2.99" (54mm - 76mm)
• Optional zoom ranges from 2.5X - 10X to 30X - 120X
Specifications
Model MSM-414L MSM-414TL
Order No. 377-972A 377-974A
Optical Tube Binocular Trinocular
Total Magnification 10X-40X
Eyepiece 10X (377-016)
Objective 1X-4X
Working Distance 80mm
Field of view 20mm-5mm
Dimensions H=13.2" x W=6.7" x D=9.3"
Mass 13.2 lbs (6kg)
Optional Accessories
Illuminated Stand
Order No. Description
377-412 Pole Type Stand (top: 12V/10W flat filament
tungsten, bottom: 5W fluorescent)
377-413* Pole Type Stand (top: 12V/10W flat filament
tungsten, bottom: 12V/10W halogen with
intensity control)
377-414 Fixed Arm Stand (top: 12V/10W flat filament
tungsten, bottom: 5W fluorescent)
377-415 Fixed Arm Stand (top: 12V/10W flat filament
tungsten, bottom: 12V/10W halogen with
intensity control)
377-416 Fixed Arm Stand (top: 5W fluorescent,
bottom: 5W fluorescent)
* Standard Accessory
F-22
F-23 (2003) full size 12/8/03 8:09 PM Page 1
MEASURING INSTRUMENTS
Stereo Microscope
Series 377
F-23
F-24 (2003) full size 12/9/03 11:35 AM Page 1
MEASURING INSTRUMENTS
Stereo Microscope
MSM-465L/MSM-464L
Series 377
MSM-465L
Features 377-990A
• Superior quality optics provide high-resolution
• Crystal sharp, high color contrast image with excellent depth
of field
• Always in sharp focus at all magnifications
• The Parfocal Optical System allows relaxed strain-free viewing
• Long working distance
• Extreme large field of view (23mm diameter)
Specifications
Model MSM-465L MSM-464L
Order No. 377-990A 377-991A
Optical Tube Binocular Binocular
Total Magnification 6X-50X 6.4X-40X
Eyepiece 10X (377-456) 10X (377-456)
Objective .6X, 1.2X, 2.5X, 5X .64X, 1X, 1.6X, 2.5X, 4X
Working Distance 89mm 89mm
Field of View 23mm (377-456) 23mm (377-456)
Dimensions (H, W, D) H=14.6" x W=13" x D=11" H=14.3" x W=13" x D=11"
Mass 15.5 lbs. (7kgs.) 15.5 lbs. (7kgs.)
Optional Accessories
Photo System and Video System
Order No. Description
377-486 Photo system for 377-990A, (A, B, C, D, see System Diagram)
377-487 Photo system for 377-991A, (A, B, C, E, see System Diagram)
377-488 Video system for 377-990A, (F, D, see System Diagram)
377-489 Video system for 377-991A, (F, G, see System Diagram)
F-24
F-25 (2003) full size 12/8/03 8:10 PM Page 1
MEASURING INSTRUMENTS
Stereo Microscope
Series 377
377-486(A,B,C,D) 377-488(F,D)
377-487(A,B,C,E) 377-489(E,G) Eyecup (ø32.5) Eyecup (ø35)
377-450 377-451
Photo system Video system
Vertical Power
Fluorescent illuminator 377-443
ring
illuminator 377-442
377-441
Auxiliary objective
1X plan objective
Universal stand
377-423
F-25
F-26 (2003) full size 12/17/03 9:25 AM Page 1
MEASURING INSTRUMENTS
PJ-A3000
Profile Projector
Series 302
Features
• A series of midsize profile projectors featuring bright, 12.40"
(315mm) diameter screens and easy-to-operate XY measure-
ment tables.
• Easy-to-read digital counters are located near the projection
screen, thereby minimizing strain associated with excessive
movement. A digital angle display eliminates the need to per-
form complex calculations.
• A floating table makes measuring quicker and easier.
Specifications
302-711A 302-712A 302-713A 302-714A
F-26
F-27 (2003) full size 12/17/03 9:27 AM Page 1
MEASURING INSTRUMENTS
Unit: mm
Projection Capacity
Contour illumination Surface illumination
Magnification
D1: Max. workpiece diameter whose edge line can be focused 10X 20X 50X 100X 10X 20X 50X 100X
on the screen center View field diameter 31.5 15.7 6.3 3.1 31.5 15.7 6.3 3.1
W 66 32.5 12.6 5 20 2 12.6 5
D2: Max. workpiece diameter whose edge line can be focused
on the screen line H PJ-A3005D-50 123.5 123.5 123.5 123.5 123.5 123.5 123.5 123.5
PJ-A3010F-100 91 91 91 91 91 91 91 91
PJ-13005F-150 103.5 103.5 103.5 103.5 103.5 103.5 103.5 103.5
PJ-13010F-200 92.5 92.5 92.5 92.5 92.5 92.5 92.5 92.5
D1 PJ-A3005D-50 224 87 27 10 198 61 27 10
PJ-A3010F-100 182 87 27 10 182 61 27 10
PJ-13005F-150 207 87 27 10 198 61 27 10
PJ-13010F-200 185 87 27 10 185 61 27 10
D2 PJ-A3005D-50 154 69 25 10 120 23 25 10
PJ-A3010F-100 154 69 25 10 120 23 25 10
PJ-13005F-150 154 69 25 10 120 23 25 10
PJ-13010F-200 154 69 25 10 120 23 25 10
Optional Accessories
Model PJ-A3010F-200 PJ-A3005F-150 PJ-A3010F-100 PJ-A3005D-50
Order No. Description 302-711A 302-712A 302-713A 302-714A
172-202 Projection lens set 10x (Standard) ● ● ● ●
172-203 Projection lens set 20x ❍ ❍ ❍ ❍
172-204 Projection lens set 50x with half reflecting mirror ❍ ❍ ❍ ❍
172-207 Projection lens set 100x with half reflecting mirror ❍ ❍ ❍ ❍
172-229 Oblique reflecting mirror 10x ❍ ❍ ❍ ❍
172-230 Oblique reflecting mirror 20x ❍ ❍ ❍ ❍
172-116 Standard scale 50mm ❍ ❍ ❍ ❍
172-117 Standard scale 2" ❍ ❍ ❍ ❍
172-118 Reading scale 200mm ❍ ❍ ❍ ❍
172-119 Reading scale 8" ❍ ❍ ❍ ❍
172-161 Reading scale 300mm ❍ ❍ ❍ ❍
172-162 Reading scale 12" ❍ ❍ ❍ ❍
172-160-2 Color filter ❍
172-160-3 Color filter ❍ ❍ ❍
176-106 Rotary table ❍ ❍
172-196 Rotary table ❍*1 ❍ ❍
176-105 Swivel center support ❍
172-197 Swivel center support ❍*1 ❍ ❍
176-107 Holder with clamp ❍*1 ❍ ❍ ❍
172-378 V block and clamp ❍*1 ❍ ❍ ❍
999678 Adapter ❍
264-141A QM Data200 (Arm mount model) ❍*2 ❍*2 ❍*2
12AAA807 Connecting cable ❍ ❍ ❍ ❍
●: Standard Accessories ❍: Optional Accessories
*1: Need to use with 999678 Adapter *2: Need to use with 12AAA807 Connecting cable
F-27
F-28 (2003) full size 12/8/03 8:12 PM Page 1
MEASURING INSTRUMENTS
PJ-H3000F
Profile Projectors:
Series 303
Features
• Three-lens mount turret that includes a 10x lens as
standard.
• Digital readout protractor screen and built-in XY
counter for efficient measurement.
• Floating-type table for speedy measurement.
• Either manual focus or power focus (with fine adjusting
wheel) model can be selected. PJ-H3010FT4-200
Three models can be selected:
• Manual Focus Model (T1)
• Powered Focus Model (T2)
• Powered Focus Model with image edge sensor (T4)
• Provided with data output ports for connection with the
M-SPC (Mitutoyo Statistical Process Control) system.
Specifications
PJ-H3000F
F-28
F-29 (2003) full size 12/8/03 8:13 PM Page 1
MEASURING INSTRUMENTS
H Max. workpiece
height
Accessories
Model
Order No.
172-271 Projection lens set 5X ❍
172-472 Projection lens set 10X ●
172-473 Projection lens set 20X ❍
172-474 Projection lens set 50X ❍
172-275 Projection lens set 100X ❍
172-116 Standard scale 50mm ❍
172-117 Standard scale 2" ❍
172-118 Reading scale 200mm ❍
172-119 Reading scale 8" ❍
172-161 Reading scale 300mm ❍
172-162 Reading scale 12" ❍ Three-Lens mount
172-555 Oblique Surface Illumination (Bifurcated Type) ❍ PJ-H3000F
172-278 Polaroid photographic attachment ❍
172-259 Polarization unit ❍
172-201 Visor ●
172-258 Green filter ❍
932105 Overlay charts (12 sheets) ❍
172-269 Machine stand ❍
172-196 Rotary table ø146mm ❍
172-289 Rotary table ø235mm ❍
172-197 Swivel center support ø80mm ❍
176-107 Clamp holder ❍
172-378 V-block ❍
512305 Halogen lamp (24V, 150W) ●
990600 Zero Set Switch for T4-type only ❍
990744 Large Hood/Visor ❍
999678 Fixture Mount Adapter (8"x4", 12"x4" only) ❍
Image edge sensor For further information
request Catalog
015930 Optoeye E1 for Micropak 2LA ❍ No. US4139.
016311 Optoeye Mounting Plate 12" ❍
Data processor
983-355A Micropak 2LA ❍
016057 EIA-232-D (RS-232C) output unit ❍
016052 Digimatic code output unit ❍
09AAA720A Extension Cable 2m (2 pcs. required, *1) ❍
264-135A Micropak 5 ❍
999536 Micropak 5 cable for T4 type with edge sensor ❍
965014 Digimatic cable 2m (2pcs. required) ❍
983-361A Quadra-check QC-220-ML15 ❍
983-361A Quadra-check QC-220E-ML15 with edge detector ❍
●: Standard accessory ❍: Optional accessory *1: Use 2 pcs. of #09AAA720A
when extending linear scale cable to Micropak 2LA.
F-29
F-30 (2003) full size 12/8/03 8:14 PM Page 1
MEASURING INSTRUMENTS
PH-3515F
Profile Projectors
Series 172
Features
• Heavy-Duty, bench-top model with horizontal
optical system.
• Erect image on Day-bright screen.
• 14" (356mm) dia. protractor screen with PH-3515F
crosshair line for easy alignment.
with
• Digital angle measurement to 1' or 0.01°.
QM-Data 200
• Floating-type workstage incorporates linear
scales for fast, accurate measurement.
• Contour illumination with halogen bulb. Surface
illumination with halogen bulb.
• Suitable for thread pitch measurements — free
from blurred or distorted images when the
workpiece is angled.
• Wide range of accessories for
various applications.
F-30
F-31 (2003) full size 12/8/03 8:14 PM Page 1
MEASURING INSTRUMENTS
Accessories
Model No. PH-3515F
Order No. 172-848-1A
172-145 Projection Lens Set 5x ❍
172-184 Projection Lens Set 10x ●
172-173 Projection Lens 20x ❍
172-165 Projection Lens Set 50x ❍
172-116 Standard scale 50mm ❍
172-117 Standard scale 2" ❍
172-118 Reading scale 200mm ❍
172-119 Reading scale 8" ❍
172-161 Reading scale 300mm ❍
172-162 Reading scale 12" ❍
050004 Machine stand ❍
172-133 Surface illumination ❍
512305 Halogen lamp (for Contour illumination) ●
172-286 Green filter ❍
932105 Overlay charts (12 sheets) ❍
172-142 Center support ❍
172-143 Center support riser ❍
172-132 Vertical holder ❍
172-144 Rotary vise ❍
172-234 V-block with clamp ❍
64AAB003 Counter tray ❍
64AAB004 Fiber optical illumination cable ❍
64PPP277 Halogen lamp (for #64AAB004) ❍
● Standard accessory
❍ Optional accessory
* At least one display must be selected.
QM-Data200
Order No. 264-141A (Arm-mount model)
Resolution .00002"/.00005"/.0001" (0.0005mm/0.001mm)
Software Standard geometric element
Geometry combination pattern
Memory: 1000 elements (max)
Dimension 7.87" (W) x 11.02" (H) x 3.54" (D) QM Data 200
KL Counter
Order No. 174-163A
Resolution .0001"/.0005"/.001" (0.001mm/0.005mm/0.01mm)
Dimension 10.87" (W) x 6.97" (H) x 3.94" (D)
*Need Counter Tray 64AAB003
KL Counter
F-31
F-32 (2003) full size 12/17/03 9:30 AM Page 1
MEASURING INSTRUMENTS
PH-A14
Horizontal Optical Comparator
Series 172
Features
• Mitutoyo’s lens technology and workmanship combine to
provide a bright, crisp image for error free inspection.
• The PH-14’s generous x, y workstage travel (8" x 4") provides
users with ample range to cover application needs.
• New location of the Y-axis handle improves ease of operation.
• The workstage provides high accuracy and can handle a
workload of up to 100 lbs.
Specifications
Order No. 172-810A
Model No. PH-A14
Projected image Inverted image
Protractor screen
Diameter 14" (356mm)
Angle Vernier reading, Resolution: 2'
Illumination
Contour 24V, 150W (515530) halogen lamp,
Telecentric illumination
Surface 24V, 150W ( 515530) halogen lamp,
Twin fiber-optic illuminator
Magnifications 10X (Standard), 20X, 50X, 100X (Option)
Magnifications Accuracy
Contour 0.1% or less
Surface 0.15% or less
Workstage
(X-axis) Projection Lenses
Table travel 8" (203mm)
Table size 16" x 6" (407 x 153mm)
Reading unit Linear Scale 10X
Resolution .00005" (0.001mm)*1 Standard 20X
(Y-axis) accessory
Table travel 4" (102mm)
Reading unit Linear Scale
Resolution .00005" (0.001mm)*1
(Z-axis)
Focusing travel 2" (50.8mm)
XY counter Option 50X
Power supply 120VAC, 50/60Hz
Dimension (W x D x H) 25.5" x 53.3" x 43.3" (648 x 1355 x 1100mm)
Weight 308 lbs (140Kg)
Max Load 100 lbs (45Kg)
*1 set by XY counter
F-32
F-33 (2003) full size 12/17/03 9:32 AM Page 1
MEASURING INSTRUMENTS
PH-A14
Diagram Unit: mm
Magnification 10X 20X 50X 100X
L A Mounting method Screw mount
Projection capacity
Field of view 35.6 17.3 7.12 3.56
Working distance A 93 40 14.6 11
Maximum workpiece width L 235 235 80 109
D
H
Optional Accessories
Order No. Description
172-011 Projection Lens 10X (Standard)
172-012 Projection Lens 20X
172-013 Projection Lens Set 50X
172-014 Projection Lens Set 100X
172-116 Standard scale 50mm
172-117 Standard scale 2"
172-118 Reading scale 200mm
172-119 Reading scale 8"
172-161 Reading scale 300mm
172-162 Reading scale 12"
172-286 Green filter
172-142 Center support
172-143 Center support riser
172-132 Vertical holder
172-144 Rotary vise
172-234 V-block
64AAA129B Machine stand (W = 23" x D = 45" x H = 20")
Weight: 129 lbs (58.53 Kg)
58AAA407 Counter tray
Data Processor and Display Counters
264-141A QM-Data 200 (Arm mount type)
Overlay Charts
201305 Combination
201306 Grid / 15° Protractor
201307 Protractor
201308 Screw Thread
201491 Radius
201493 Radius / 10° Protractor
F-33
F-34 (2003) full size 12/8/03 8:18 PM Page 1
MEASURING INSTRUMENTS
PV-5000, PV-600A
Profile Projector
Features
• Floor model that uses a downward illumination system.
• Digital readout protractor screen (Zero-setting,
ABS/INC switchable) for easy and error-free angle
measurement. (PV5000)
• Angled screen allows projected images to be easily
traced or compared with a template.
• The oblique surface illumination system provides
clear and bright images, allowing easy inspection of
non-reflective workpieces such as plastic parts or
printed materials.
PV-600A
PV-5000
Specifications
PV-5000, PV-600A
Model PV-5000 PV-600A 319-209
Order No. 304-201-1A 305-103A
Diameter 20" (508mm) 23.6" (600mm)
Protractor
Screen ±370°, 1' or 0.01°
Angle 360°, 1' Vernier
digital reading, zero
Measure reading
setting, ABS/INC
Lens (Option) 5X, 10X, 20X, 50X, 100X 5X, 10X, 20X, 50X, 100X
Magnification Contour ±0.1% or less
Accuracy Surface ±0.15% or less
Contour Telecentric system with condenser lens 319-222-1
24V, 150W Halogen Lamp
Illumination 2 Stage brightness selector
Surface Twin oblique surface illumination
24V, 150W Halogen Lamp, 2 stage brightness
(5x, 10x, 20x only)
Weight
396 lbs (180 kg) 550 lbs (250kg)
(main unit)
Stage
Code No. 319-109 319-209 319-222-1 319-225-1
Projector PV-600 PV-5000 PV-5000 PV-5000 319-225-1
Travel 4 x 2" 4 x 2" 4 x 2" 8 x 4"
Size 11.8 x 9.4" 11.8 x 9.4" 11.8 x 9.4" 14.9 x 9.8"
Glass Size 7.4 x 6.3" 7.1 x 5.9" 7.1 x 5.9" 10.5 x 6.7"
Measuring Device Micrometer Head Micrometer Head Linear Scale Linear Scale
Others — — X-axis floating XY floating
table table
F-34
F-35 (2003) full size 12/8/03 8:19 PM Page 1
MEASURING INSTRUMENTS
PV-5000
When using Cross-travel stage (319-209,319-222-1,319-225-1) Unit: Inch
Illumination Contour Surface
Magnification 5X 10X 20X 50X 100X 5X 10X 20X 50X 100X
View field dia. 3.93 1.96 .98 .39 .19 3.93 1.96 .98 .39 .19
L 2.24 2.24 2.24 1.27 .88 1.25 2.24 2.24 1.27 .88
H 4.92 7.12 8.11 3.42 3.42 4.92 7.12 8.11 3.42 3.42
Max. work-
D 5.67 5.67 5.67 2.52 1.77 — — — — — piece height H D Max. workpiece
diameter whose edge
PV-600A L line can be focused on
When using Cross-travel stage (319-109) Unit: Inch the screen center
F-35
F-36 (2003) full size 12/8/03 8:20 PM Page 1
MEASURING INSTRUMENTS
Microstages
Series 319
These microstages are designed to be mounted
on Mitutoyo optical instruments such as profile
projectors and measuring microscopes. Models
are available for use with micrometer heads or
DRO counters via built-in linear scales
319-102 with Series 319-101 with Series 152
150 Micrometer Heads and 252 Micrometer Heads
in both X and Y axis
Specifications
Microstages
Inch/Metric
Order No. Travel Table Size Glass Size Shank DIA. Height Mounting Pitch Weight
319-101 2" x 2" 6" x 6" Ø3.15" Ø.709" 1.56" 4-M4 (110mm x 70mm) 12.5 lbs.
319-102** 2" x 2" Ø5.75" Ø3.94" Ø.709" 1.63" 4-M4 (110mm x 70mm) 13.0 lbs.
319-109* 4" x 2" 11.8" x 9.4" 7.5" x 6.3" Ø.709" 2.17" 4-M6 (210mm x 140mm) 31.9 lbs.
319-221-1 4" x 2" 10.6" x 6" 6.1" x 3.8" Linear Scale AT-112 2.24" 4-M4 (110mm x 70mm) 26.4 lbs.
319-222-1 4" x 2" 11.8" x 9.4" 7.5" x 6.3" Linear Scale AT-112 2.95" 4-M6 (210mm x 140mm) 40.7 lbs.
319-225-1*** 8" x 4" 14.96" x 9.84" 11.02" x 7.09" Linear Scale AT-112 2.95" 4-M6 (210mm x 140mm) 40.7 lbs.
319-226-1* 8" x 3" 16.9" x 11" 12.2" x 6.7" Linear Scale AT-112 4.00" 4-M6 (210mm x 140mm) 66.0 lbs.
*: with ±5° Swivel.
**: with rotary stage.
***: with ±3° Swivel.
F-36
F-37 (2003) full size 12/8/03 8:20 PM Page 1
MEASURING INSTRUMENTS
172-119
172-117
• Used for checking magnifying accuracy. • Specially designed for inspecting the magnified image
of a standard scale on the projection screen.
Specifications Specifications
Metric Metric
Range Order No. Graduation Accuracy Range Order No. Graduation Accuracy
50mm 172-116 0.1mm 3.25µm 200mm 172-118 0.5mm 18µm
80mm 172-330 0.1mm 3.4µm 300mm 172-161 0.5mm 19.5µm
Inch 600mm 172-329 0.5mm 24µm
Range Order No. Graduation Accuracy Inch
2" 172-117 .01" .00013" Range Order No. Graduation Accuracy
8" 172-119 .02" .00071"
Overlay Charts 12" 172-162 .02" .00077"
The reference drawings of the overlay charts offer a larger scope of application Specifications
and increase the efficiency of the Mitutoyo profile projectors. Line width:
The charts are delivered in a size of dia. 10"(250mm), 12"(300mm), 14" 0.05, 0.08, 0.01 and 0.12mm
(340mm) so that they are identical with the screens of the Mitutoyo projectors. Graduation lines, linear:
L
This results in a large range of fixed scales or precision reference scales which ±(0.04 + 30000 )mm
can be tested quickly and easily. Length, height, parallelism, angle, radius, 0.05mm on 300mm
taper, bore position, dia. as well as all standardized thread and tooth profiles Graduation lines angular:
can be tested. ±25 angular seconds
All charts are made of distortion-free special plastics compound and are provid- 0.036mm on 300mm
ed with a protective coating. Thermal expansion coefficient
of plastics:
2.7x10-5 K-1
0.08mm on 300mm
and 10°C difference
Overlay Inch Metric
10" Screen 12" Screen 14" Screen 250mm Screen 300mm Screen 340mm Screen
Combination 201301 511344 201305 –– –– ––
Grid/15° Protractor 201302 511345 201306 201380 201386 201392
Radius/10°Protractor 201492 511349 201493 201381 201387 201393
Radius 201490 511348 201491 201382 201388 201394
Protractor 201303 511346 201307 201383 201389 201395
Screw Thread 201304 511347 201308 201384 201390 201396
For 5X, 10X, 20X, and 50X magnifications.
F-37
G-01 (2003) full size 12/11/03 3:52 PM Page 1
Measuring Instruments
(Laser Scan Micrometers)
MEASURING INSTRUMENTS
Out of roundness
(T.I.R)
Reference
edge
Diameter Interval Interval
measurement measurement measurement
Enamel wire (Coated wire) Pins located in parallel Gap of rollers Rubber roller
Cable Roller bearing
Spring wire Motor shaft
Tungsten wire
Pressure hose
Reference Tape width
Height edge Linearity
measure- measurement measure-
ment* ment*
Reference
edge
Transparent part
measurement* Scanning
G-2
G-03 (2003) full size 12/8/03 8:26 PM Page 1
MEASURING INSTRUMENTS
G-3
G-04 (2003) full size 12/8/03 8:27 PM Page 1
MEASURING INSTRUMENTS
Features
• High-accuracy renewal model of LSM-500 Series.
• The applicable display unit is LSM-6100 only.
• The LSM-5000(s) / 6000(s) / 6900 are not available.
• The protection grade is IP64.
• An ID unit for correcting the optical error of the
measuring unit is provided. The ID unit (Correction
ROM) has the same serial No. as the measuring unit
and inserts in the ID slot of the display unit.
• The external dimensions and mounting dimensions
are the same as those of the LSM-500 Series.
Specifications
Model LSM-500H LSM-501 H LSM-503H LSM-506H LSM-512H
Order No. 544-552 544-555 544-558 544-572 544-575
Measuring range mm 0.005 to 2 0.05 to 10 0.3 to 30 1 to 60 1 to 120
Reading*1 µm 0.01 to 10 0.02 to 100 0.05 to 100 0.1 to 100
Repeatability *2 *3 µm ±0.04 ±0.05 ±0.15 ±0.5 ±1.2
Linearity *2 *4 *5 Whole range µm ±0.3 ±0.5 ±1.0 ±3.0 ±6.0
Small range µm – ±(0.3+0.1∆D) ±(0.6+0.1∆D) ±(1.5+0.5∆D) ±(4.0+0.5∆D)
Positional error *2 *6 µm ±0.4 ±0.5 ±1.5 ±4.0 ±8.0
Measuring area *7 mm 1x2 2x10 (0.05 to 0.1) 10x30 20x60 30x120
(Measuring range) 4x10 (0.1 to 10)
Number of scans /sec 1600
Laser wavelength Nm 650 (Visible LD), 1.3mW (peak)
Laser scanning speed m/sec 38 57 113 226 452
Operating Temperature °C 0 to 40
environment Humidity %RH 35 to 85 (without condensation)
Altitude m 2000 or less
Storage Temperature °C -15 to 65
environment Humidity %RH 35 to 85 (without condensation)
Protection level IP64
*1: Selectable
*2: Accuracy inspection environment/Temperature: 20°C ± 1°C, Humidity: 50% ± 10%
*3: ±2σ when measuring a gage at the measurement interval of 1.28 sec, and for 2 minutes.
*4: Specified at the center of the measurement region.
*5: ∆D: Diameter difference from the master gage.
*6: An error caused by workpiece shift either in the optical axis direction or in the scanning direction.
*7: The area given by [measuring range on the optical axis] x [measuring range in the scanning direction].
G-4
G-05 (2003) full size 12/8/03 8:27 PM Page 1
MEASURING INSTRUMENTS
LSM-500H
Ultra-Fine Wire Measuring Unit
Unit: inch (mm)
LSM-501H
Fine Wire Measuring Unit
Unit: inch (mm)
G-5
G-06 (2003) full size 12/8/03 8:28 PM Page 1
MEASURING INSTRUMENTS
LSM-506H
Wide Range
Measuring Unit
Unit: inch (mm)
G-6
G-07 (2003) full size 12/8/03 8:29 PM Page 1
MEASURING INSTRUMENTS
LSM-512H
Ultra Wide Range Measuring Unit
G-7
G-08 (2003) full size 12/8/03 8:30 PM Page 1
MEASURING INSTRUMENTS
LSM-6100
Display Unit for LSM-500H Series
Features
• The measurement functions of LSM-6000 can be used.
• The measurement unit connectable is LSM-500H
Series only.
• LSM-500 and LSM-902 cannot be connected.
Specifications
Order No. 544-070A
Display Fluorescent display 16-digit + 11-digit, Guidance LEDs
Measurement Segment designation 1 to 7 (1 to 3 for Transparent)
function* Edge designation 1 to 255
Averaging method Simple averaging 1 to 2048 Moving averaging 32 to 2048
Tolerance judgement (GO, ±NG); Multi-limit judgement (7classes); Offset/Zero-set;
Mastering; Abnormal data elimination; Automatic workpiece detection; Reference value
setting; Data output condition; Laser power deterioration; Sample measurement; Statistical
processing; Dual-program measurement; Automatic measurement using edge mode;
Workpiece position display; Transparent object measuring (Segment: 1 to 3); Key-lock
function; mm / inch changeover; Dual-gauge calibration; Selection of resolution; Display of a
comma to mark the thousandths position; Judgement in ready state; None-display
unnecessary digits; Distinction of measurement part model; Buzzer; Tolerance judgement
(GO, ±NG) in a standby state +Analog output; Group judgement; Fine wire measurement
(only LSM-500H); Dual-Measurement (Two measurement part connection) (Option)
Scanning signal monitor connector Provided as standard (with the plug)
Remote interlock connector Provided as standard (with the plug)
Power switch Key switch used
Built-in interface RS-232C, Foot switch connector; I/O analog interface
Optional interface DCU slot Digimatic code output unit (2-ch)
Expansion slot (1-slot) 2nd I/O analog l/F; BCD l/F; GP-IB l/F
Power supply AC100V to 240V±10%, 50/60Hz, 30W
Operating Temperature 0°C to 40°C
environmental Humidity 35%RH to 85 %RH (without condensation)
Altitude 2000m or less
Storage Temperature -20°C to 70°C
environmental Humidity 35%RH to 85 %RH (without condensation)
Safety Compliant with EN61010-1 (Over Voltage Category II, Pollution Degree 2)
*: The combination of functions is limited, details are described in the users manual.
G-8
G-09 (2003) full size 12/8/03 8:31 PM Page 1
MEASURING INSTRUMENTS
LSM-902 / 6900
LSM-902 (Measurement Unit) & LSM-6900 (Display Unit)
are the most accurate 25mm measurement range
Laser Scan Micrometers in the world.
LSM-902
Adjustable workstages (optional) LSM-6900
Features
• Measuring range – 0.1 to 25mm covers most precision • LSM-500 Series and LSM-5000(s) / 6000(s) cannot be
parts. connected.
• Repeatability – ±0.05µm highest repeatability for a • Be sure to use it in the measurement unit and display unit
25mm LSM in the world. of the same serial number/code number.
• Linearity – ±0.5µm over the entire range, and higher • Simultaneous connection of two measurement units
linearity in the small range. cannot be performed.
• High Resolution – Improves measurement accuracy.
• Stable edge detection by using new algorithm.
• Many functions of the multi-function type display unit
LSM-6000 are available
G-9
G-10 (2003) full size 12/8/03 8:32 PM Page 1
MEASURING INSTRUMENTS
LSM-902 / 6900
Dimensions
Unit: inch (mm)
LSM-902 LSM-6900
Specifications
LSM-902
Measuring range .004~1.0" (0.1~25mm)
Reading (Selectable) .000001~.0005" (0.01~10µm)
Repeatability*1 ±.000002" (±0.05µm)*2
Linearity*1 Whole range ±.000020" (±0.5µm)*3
Small range ±(.000012 + .0001 ∆D)" [∆D: inch]*3 *4 ±(0.3 + 0.1 ∆D)µm [∆D:mm] *3 *4
Positional error*1 *5 ±.000020" (±0.5µm)
Measuring region ±0.6 x 1.0" (±1.5 x 25mm)*6
Number of scans 800/sec
Laser wavelength 650nm [Visible LD], 1.5mW (peak)
Laser scanning speed 2240"/sec (56m/sec)
LSM-6900
Display Fluorescent display 16-digit + 11-digit, Guidance LEDs
Measuring Segment designation 1 to 7 (1 to 3 for Transparent material)
function*7 Edge designation 1 to 255
Averaging method Simple averaging: 1 to 2048 Moving averaging: 32 to 2048
Tolerance judgement (GO,±NG); Multi-limit judgement (7 classes); Offset/Zero-set;
Abnormal data elimination; Automatic workpiece detection; Reference value setting;
Data output condition; Laser power deterioration; Sample measurement;
Statistical processing; Dual-program measurement; Automatic measurement using
edge mode; Workpiece position display; Transparent object measuring; Key-lock
function; mm/inch changeover; Dual-gage calibration; Selection of resolution;
Judgement in ready state; Display of a comma to mark the thousandths position;
Mastering; None-display unnecessary digits; Group judgement
Scanning signal monitor connector Provided as standard (with the plug)
Remote interlock connector Provided as standard (with the plug)
Power switch Key switch used
Built-in interface RS-232C; Foot switch connector; I/O analog interface
Optional interface DCU slot Digimatic code output unit (2-ch)
Expansion slot (1-slot) 2nd I/O analog I/F; BCD I/F; GP-IB I/F;
Power supply AC100V~240V±10%, 50/60Hz, 40VA
*1 Accuracy inspection environment/Temperature 20°C±1°C, Humidity: 50%±10%
*2 The repeatability is determined by the value for ±2o- at the measurement interval of 1.28 sec. *3 Specified at the center of the measurement region.
*4 ∆D: Diameter difference to master gage. *5 An error due to workpiece shift either in the optical axis direction or in the scanning direction.
*6 The area given by [measuring range on the optical axis] x [measuring range in the scanning direction.]
*7 The combination of functions is limited, details are described in the user's manual.
G-10
G-11 (2003) full size 12/8/03 8:33 PM Page 1
MEASURING INSTRUMENTS
Optional Accessories
Calibration Gage Sets Air Blow Covers
• The Calibration Gage Sets are a set of standard gages • If using your LSM in an environment with smoke or dust,
used for calibrating Laser Scan Micrometers. The the Air Blow Cover helps to prevent the emission/reception
indicated dimensional value is the result of one position window from being soiled by blowing clean air out of the
in a single direction on each gage. mouth provided on the measuring unit.
• Air cleaner (957608)
also required.
G-11
G-12 (2003) full size 12/8/03 8:34 PM Page 1
MEASURING INSTRUMENTS
Optional Accessories
Adjustable Workstages
• Aids in measuring various workpiece diameters by
means of the up/down and right/left slide mechanism.
• Optimum for quality control of precision shafts, rollers,
Order No. 02AGD490 02AGD520
pin gages, etc.
H 3.84" (97.5) 4.57" (116)
L 11.81" (300) 15.67" (398)
W 3.54" (90) 3.94" (100)
h1 6.57" (167) 7.95" (202)
Dimensions h2 7.01" (178) 8.39" (213)
Unit: inch (mm) l1 18.11" (460) 25.2" (640)
w1 7.09" (180) 7.87" (200)
w2 11.81" (300) 17.32" (440)
Overall 19.88" (505) 29.33" (745)
travel
02AGD490
02AGD400 02AGD520
02AGD370
02AGD680
02AGD280
Specifications
Order No. 02AGD400 02AGD280 02AGD490 02AGD520 02AGD370/02AGD680
Application LSM-501H LSM-902 LSM-503H LSM-506H LSM-9506
Horizontal stroke 5.12" (130mm) 5.12" (130mm) 7.87" (200mm) 11.81" (300mm) 7.87" (200mm) / 11.81" (300mm)
Vertical stroke 1.26" (32mm) 18.50" (47mm) 1.38" (35mm) 1.77" (45mm) 1.77" (45mm)
Maximum 1.1 lbs. (0.5kg) 1.1 lbs. (0.5kg) 4.4 lbs. (2.0kg) 11 lbs. (5.0kg) 4.4 lbs. (2.0kg) / 11 lbs. (5.0kg)
workpiece load
Mass 2.2 lbs. (1.0kg) 1.8 lbs. (0.8kg) 10.78 lbs. (4.9kg) 21.34 lbs. (9.7kg) 8.4 lbs. (3.8kg) / 10.56 lbs. (4.8kg)
Standard • V-block (02AGD420) • V-block (02AGD420) • V-block (02AGD420) • V-block (02AGD550) • V-block (02AGD550)
accessories x 2pcs. x 2pcs. x 2pcs. x 2pcs. x 2pcs.
• Workpiece stopper • Workpiece stopper • Workpiece stopper • V-block (02AGD560) • V-block (02AGD560)
(02AGD430) (02AGD430) (02AGD430) • V-block (02AGD570) • V-block (02AGD570)
G-12
G-13 (2003) full size 12/8/03 8:35 PM Page 1
MEASURING INSTRUMENTS
Optional Accessories
V-blocks Adjustable V-blocks
Unit: inch (mm) • Optional accessories for adjustable workstages.
Specifications
Workpiece stopper
Order No. 02AGD440 02AGD580
(02AGD430) Application Adjustable workstage for Adjustable workstage for
Unit: inch (mm)
LSM-501H (02AGD400), LSM-506H (02AGD520),
Adjustable workstage for Adjustable workstage for
LSM-902 (02AGD280), LSM-9506 (02AGD680)
Adjustable workstage for
LSM-503H (02AGD490)
Point angle 60° 60°
Maximum workpiece length 4.33" (110mm) 12.4" (315mm)
on 02AGD400 / 02AGD280 on 02AGD520
• Used with 02AGD400, 02AGD280 or 9.06" (230mm) on 02AGD490 on 02AGD680
02AGD490 adjustable workstage for Horizontal stroke (A) .2" (5mm) or more .39" (10mm) or more
positioning the workpiece. Center point feeding force 1.1kgf 3.2kgf
• Mass: 0.05kg Mass .4 lbs. (0.18kg) 1.87 lbs. (0.85kg)
G-13
H-01 (2003) full size 12/11/03 3:52 PM Page 1
Measuring Instruments
(Hardness Testing Instruments)
MEASURING INSTRUMENTS
H-2
H-03 (2003) full size 12/8/03 8:43 PM Page 1
MEASURING INSTRUMENTS
Features
• Closed-loop control of testing forces
• Primary and final forces (loads) are applied with unparalleled
accuracy and repeatability
• Extended indenter arm reaches inside diameters and hard to
reach surfaces at eye level, allowing the operator to easily see
where the indenter addresses small or hard to reach parts
• Automatic setting of preliminary test force and application of
total test force
• Indenter escape function allows automatic removal of
preliminary test force at end of test cycle
• Touch screen operation with a back-lit LCD graphic display HR-521
• Hardness scale is set automatically via the touch screen
• Cylindrical and spherical surface compensation
• Auto conversion to all hardness scales or tensile strength
• Powerful processing capability with 1024 data point memory
• OK/±NG tolerance judgement
• Various data output formats, including SPC and RS-232C
Specifications
Model HR-521 HR-523
Order No. 810-202-02A 810-204-02A
Preliminary Test Force 29.42N (3kgf), 98.07N (10kgf)
Test Force Rockwell 588.4N (60kgf), 980.7N (100kgf), 1471N (150kgf)
Rockwell Superficial 147.1N (15kgf), 294.2N (30kgf), 441.3N (45kgf)
Force Control Automatic control (unloading/duration/unloading) with spring deformation feed back
Console/Display Unit Touch screen operation with back-lit LCD graphic display
Test Force Selection By touch screen
Table up/down drive Manual (w/Auto-brake mechanism) Power-Drive (for full-automatic measurement)
Load Duration 0 to 120 sec. (1 sec. step)
Maximum Specimen Height Height: 205mm Depth: 150mm from center of indenter shaft
Display Indication Hardness value, Converted hardness value, Test conditions, OK/NG tolerance judgement,
Functions statistical processing result
Rockwell/Rockwell superficial hardness testing. Continuous testing.
Cylindrical/spherical surface compensation, data offset
Hardness conversion (HV, HK, HRA/B/C/D/F/G/15T/30T/45T/15N/30N/45N, HS, HB,
HBW, tensile strength)
OK/±NG tolerance judgement, measured data editing, data memory (max 1024 data)
SPC calculation (No. of data, max/min/mean values, range, upper/lower limit values,
standard deviation, No. of passing/defective) Histogram, x̄-R chart
Data Output RS-232C, SPC, Centronics
Dimensions (W x D x H) 9.84” x 26.38” x 23.82” (250 x 670 x 605mm)
Mass Approx. 132 lbs (60kg)
H-3
H-04 (2003) full size 12/8/03 8:43 PM Page 1
MEASURING INSTRUMENTS
ARK-600 ATK-600
• Flat anvil diameter: 2.52" (64mm). • Flat anvil diameter: 2.52" (64mm).
• Hardness test block (30 to 35HRC). • Hardness test block (30 to 35HRC), •(60 to 65HRC),
• Hardness test block (60 to 65HRC). (90 to 95HRB), (64 to 96HR30N), (74 to 79HR30T).
• Hardness test block (90 to 95HRB). • Machine cover.
• Power cable.
• Machine cover.
• User’s manual.
• Power cable.
• Level
• User’s manual.
Specifications Specifications
Model ARK-600 ARK-601 Model ATK-600 ATK-601
Order No. 810-218A 810-220A Order No. 810-257A 810-258A
Preliminary test force 98.07N (10kgf) Preliminary test force 98.07N (10kgf), 29.42 (3kgf)
Test force 588.4N (60kgf), 980.7N (100kgf), Test force 588.4N (60kgf), 980.7N (100kgf), 1471N (150kgf),
1471N (150kgf) 147.1N(15kgf), 294.2N(30kgf), 588.4N(45kgf)
Table up/down drive Manual (with Loading Navigator) Table up/down drive Manual (with Loading Navigator)
Load control Automatic (loading, duration, unloading) Load control Automatic (loading, duration, unloading)
Load duration Automatic (3s to 5.5s) or manual Load duration Automatic (3s to 5.5s) or manual
Display LED (4-digit) Display LED (4-digit)
Hardness increment 0.1 (for each scale) Hardness increment 0.1 (for Rockwell each scale), 0.2 Rockwell Superficial (for each scale)
Specimen Specimen
Maximum height 5.51" (140mm) 12.60" (320mm) Maximum height 5.51" (140mm) 11.02" (280mm)
on Flat Anvil on Flat Anvil on Flat Anvil on Flat Anvil
5.91" (150mm)* 13.00" (330mm)* 5.91" (150mm)* 11.42" (290mm)*
on Round Table on Round Table on Round Table on Round Table
Maximum depth 4.8" (122mm) from center of indenter shaft Maximum depth 4.8" (122mm) from center of indenter shaft
Output RS-232C, SPC Output RS-232C, SPC
Power supply 120V AC (±10%), 60Hz Power supply 120V AC (±10%), 60Hz
Power consumption 30VA Power consumption 30VA
Dimensions (W x D x H) 8.27 x 19.13 x 26.77" 8.27 x 19.13 x 33.86" Dimensions (WxDxH) 8.27 x 19.13 x 28.35" 8.27 x 19.13 x 33.86"
(210 x 486 x 680mm) (210 x 486 x 860mm) (210 x 486 x 720mm) (210 x 486 x 860mm)
Mass 88 lbs. (40kg) 99 lbs. (45kg) Mass 93 lbs. (42kg) 99 lbs. (47kg)
* Minimum height: .39" (10mm) * Minimum height: .39" (10mm)
H-4
H-05 (2003) full size 12/8/03 8:44 PM Page 1
MEASURING INSTRUMENTS
OPTIONAL ACCESSORIES
For Rockwell/Rockwell Superficial
Type Hardness Testing machine
Flat anvil Round table
H-5
H-06 (2003) full size 12/8/03 8:45 PM Page 1
MEASURING INSTRUMENTS
Optional Accessories
For Rockwell/Rockwell Superficial Type Hardness Testing machine
H-6
H-07 (2003) full size 12/8/03 8:45 PM Page 1
MEASURING INSTRUMENTS
Vickers Hardness
In the Vickers hardness test, a diamond pyramid indenter
with a 136° angle between opposite faces is pressed into
the specimen under a test force F (kgf). The hardness num-
ber (HV) is obtained by dividing F by the area, A (mm2), of
contact between the indenter and specimen. This area is
calculated from the diagonal length, d (mm), of the inden-
tion when the indenter is removed.
The Vickers hardness test is the
most versatile hardness testing
136°
method of those that use different
load settings. The Micro-Vickers
hardness test, which accepts load
settings of 1 kgf (9.807N) or less,
is especially well suited for indus-
trial production today, where accu- Polished Surface
racy requirements are increasing
due to technology improvements.
d
H-7
H-08 (2003) full size 12/8/03 8:46 PM Page 1
MEASURING INSTRUMENTS
The HM Series
Standard Microhardness Testers
Features
• Eight testing forces from 10gf to 1,000gf.
• Convenient turret mounted indenter(s)
and high resolution objective lenses.
• Dual line filar eyepiece.
HM-101 HM-112
Digital models also include:
• LCD display panel with scale conver-
sions and statistical data processing.
• Inch/metric Digimatic Micrometer heads
on the X-Y stage
• Up to 2 indenters and 3 objectives can
be fitted to an automatic motorized turret
on some models.
Specifications
Model HM101 HM112 V HM122 K HM122 V/K
Order No. 910-124A 810-126A 810-127-03A 810-127-02A
Supplied Indenter VICKERS VICKERS KNOOP VICKERS/KNOOP
Test force* 98.07mN(10g), 245.2mN(25g), 490.3mN(50g), 980.7mN(100g),
1961mN(200g), 2942mN(300g), 4903mN(500g), 9807mN(1000g)
Test force selection Dial
Loading control Automatic (loading, duration, unloading)
Load duration 5s–30s 5s to 99s (specified in 1-second increments)
Loading speed 60µm/sec.
Objective Lens 5x, 10x 50x, 10x 50x, 20x, 10x 50x, 20x, 10x
Measuring microscope
total magnification 500x, 100x 500x, 100x 500x, 200x, 100x 500x, 200x, 100x
Filer eyepiece
Minimum reading 0.2mm 0.01µm 0.01µm
Magnification 10x
Type Micrometer Drum Digital Optical Encoder
XY stage
Dimension 100 x 100mm 100 x 100mm
Travel range 25 x 25mm 25 x 25mm
Minimum reading 0.01mm 0.001mm
Specimen
Maximum height 95mm
Maximum depth 150mm
Turret Manual Manual Motor Drive Motor Drive
Display Function Conversion;
Hard: TENS, HS, HBS, HR15N, HR30N, HR45N, HRA, HRD, HRC, HK, HV, OFF
Soft: TENS, HR15T, HR30T, HR45T, HRA, HRF, HRB, HRG, HK, HV, OFF
OK/NG Judgement
Curve correction: 0.01 to 200.00mm
Data processing;
Number to measurements 2 to 256 data
Statistical list: N, Max., Min., Average, Range, High, Low, Good, Over, Under, SD(n-1), SD(n)
Output RS-232C, SPC, Centronics
Dimensions Main unit: W=16.1 x D=23.6 x H=23.2" (410 x 600 x 590mm)
Display: W=6.5 x D=10.2 x H=4.1" (165 x 260 x 105mm)
Weight Main unit: 92.4 lbs. (42kg)
Power supply 120V AC (±10%), 60 Hz
Power consumption 20VA 60VA
H-8
H-09 (2003) full size 12/8/03 8:46 PM Page 1
MEASURING INSTRUMENTS
HM-114
MVK-H3
Specifications
Model HM114 MVK-H3
Order No. 810-128A 810-120A
Test force 9.807mN(1gf),19.61mN(2gf), 0.4903mN (0.05gf), 1.961mN(0.2gf),
29.42mN(3gf), 49.03mN(5gf), 2.942mN(0.3gf), 4.903mN(0.5gf),
98.07mN(10gf), 245.2mN(25gf), 9.807mN(1gf), 29.42mN(3gf),
490.3mN(50gf), 980.7mN(100gf), 49.03mN(5gf), 98.07mN(10gf),
1961mN(200gf), 2942mN(300gf), 245.2mN(25gf), 490.3mN(50gf),
4903mN(500gf), 9807mN(1000gf), 980.7mN(100gf), 1961mN(200gf),
19610mN(2000gf) 2942mN(300gf),4903mN(500gf),
9807mN(1000gf),19610mN(2000gf)
Test force selection Dial
Load control Automatic (loading, duration, unloading)
Load duration 5 to 99 sec (specified in 1-second increments) 5-60 sec.
Objective 100X, 50X, 10X 100X,10X
Measuring microscope
Total magnification 1000X, 500X, 100X 1000X, 100X
Measuring range 70x70µm, 175x175µm, 700x700µm 70x70µm, 700x700µm
Minimum reading 0.01µm 0.01µm
XY stage
Dimensions 100 x 100mm
Travel range 25 x 25mm
Minimum reading 0.001mm
Specimen
Maximum height 3.74" (95mm) 3.54" (90mm)
Maximum depth 5.9" (150mm) 3.94" (100mm) from center of indenter shaft
Optical path 2-way (microscope/photographic)
Display LCD 5-digit LED for D1, D2, hardness and LCD for data processing
Output RS-232C, Centronics, SPC
Power supply 120V AC (±10%) 60Hz
Power consumption 20VA
Dimensions 16.14 x 20.75 x 21.34" (410 x 527 x 542mm)
Mass 92.4 lbs. (42kg) 85.8 lbs. (39kg)
H-9
H-10 (2003) full size 12/8/03 8:47 PM Page 1
MEASURING INSTRUMENTS
Features
• Standard Vickers indenter on a manual turret (HM113) or both HM123
Vickers and Knoop on a motorized rotating turrett (HM123).
• Standard objective lenses are 10x and 50x (HM113) or 10x, 20x
and 50x (HM123).
• Eight testing forces from 10gf to 1000gf.
• Digimatic Micrometer heads are standard on the X-Y stage.
• Data processing functions:
Hardness scale conversions
Statistical calculations
High and Low limits
OK/NG setting
• Digital outputs RS-232C and Mitutoyo’s SPC are standard.
Specifications
Model HM113 HM123
Order No. 810-969A 810-990-02A
98.07mN (10g), 245.2mN (25g), 490.3mN (50g), 980.7mN (100g)
Test Force
1961mN (200g), 2942mN (300g), 4903mN (500g), 9807mN (1000g)
Test Force Selection Dial
Standard Indenter Vickers Vickers + Knoop
Loading Control Automatic (loading, duration, unloading)
Load Duration 5s to 99s (specified in 1-second increments)
Loading Speed 60µm/sec
Objective 50x, 10x 50x, 20x, 10x
Screen
Total Magnification 1250x, 250x 1250x, 500x, 250x
XY Stage
Dimension 100 x 100mm
Travel Range 25 x 25mm
Minimum Reading 0.001mm
Specimen
Maximum Height 95mm
Maximum Depth 150mm
Turret Manual Motor drive
Display Function Conversion:
Hard: TENS, HS, HBS, HR15N, HR30N, HR45N, HRA, HRD, HRC, HK, HV, OFF
Soft: TENS, HR15T, HR30T, HR45T, HRA, HRF, HRB, HRG, HK, HV, OFF
OK/NG Judgement
Curve correction: 0.01 to 200.00mm
Data processing:
Number to measurements 2 to 256 data
Statistical list: N, Max. Min. Average, Range, High, Low, Good, Over, Under,
SD(n-1), SD (n)
Output RS-232C, SPC, Centronics
Main Unit: W=16.1 x D=23.6 x H=23.2” (410 x 600 x 590mm)
Dimensions
Display: W=6.5 x D=10.2 x H=4.1” (165 x 260 x 105mm)
Weight Main Unit: 92.4 lbs (42kg)
Power Supply 120V AC (±10%), 60Hz
Power Consumption 60VA
H-10
H-11 (2003) full size 12/8/03 8:48 PM Page 1
MEASURING INSTRUMENTS
HV112/114
HV113/115 AVK-CO
Specifications
Model HV112 HV113 HV115 HV114 AVK-C0
Order No. 810-163A 810-981A 810-985A 810-165A 810-160A
Test force 49.03N (5kgf), 1.961N (0.2kgf), 9.807N (1kgf), 294.2N (30kgf) 9.807N (1kgf), 4.903N (5kgf), 9.807(1kgf)49.03N (5kgf)
98.07N (10kgf), 4.903N (0.5kgf), 19.61N (2kgf), 490.3N (50kgf) 19.61N (2kgf), 98.07N (10kgf), 98.07N (10kgf), 196.1N (20kgf)
196.1N (20kgf), 2.942N (0.3kgf), 24.51N (2.5kgf), 29.42N (3kgf), 196.1N (20kgf) 294.2N (30kgf), 490.3N (50kgf)
Test force selection Dial
Loading accuracy ±1%
Load control variable 20~200µ/s Automatic (loading, duration, unloading) Automatic
Load duration 5~99 sec. 5s to 30s (in 5-sec. increments)
Objective 10X, 20X 10X
Measuring microscope
Total magnification 200X 100X
Measuring range 350, 700µm — 350, 700mm — 800 x 800µm
Minimum reading 0.1µm — 0.1µm — 1µm by digit counter
Video monitor
Camera — CCD — CCD —
Display — 9" monochrome CRT — 9" monochrome CRT —
Total magnification — 250X, 500X — 250X, 500x —
Monitoring range — 260 x 330µm, 520 x 670µm — 520 x 670µm, 260 x 330µm —
Measuring range — 200 x 280µm, 410 x 570µm — 410 x 570µm, 200 x 280µm —
Minimum reading — 0.1µm — 0.1µm —
Display Function Conversion:
Hard: TENS, HS, HBS, HR15N, HR30N, HR45N, HRA, HRD, HRC, HK, HV, Soft: TENS, HR15T, HR30T, HR45T, HRA, HRF, HRB,
HRG, HK, HV, Statistical list; N, Max., Min., Average, Range, High, Low, Good, Over, Under, SD(n-1), SD(n-1), SD(n)
OK/NG Judgement, Curve correction; 0.01 to 200.00mm
Specimen
Maximum height 8.07" (205mm) or Flat anvil
Maximum depth 6.7" (170mm) from center of indenter shaft
Optical path 2-way switchable (microscope/photograph) 1-way
Output SPC, RS-232C
Centronics
Power supply 120V AC (±10%) 60Hz
Dimensions (WxDxH) 9.7" x 20.3" x 31.3" 12.99 x 22.83 x 27.76"
Main Unit only (245~515~770mm) (330~580~705mm)
110 lbs. 121.4 lbs. 110 lbs. 121.4 lbs. 108 lbs.
Mass (50kg) (55.2kg) (50kg) (55.2kg) (49kg)
* 7.48" (190mm) if using 50 x 50mm-travel XY stage (No. 810-012).
H-11
H-12 (2003) full size 12/8/03 8:49 PM Page 1
MEASURING INSTRUMENTS
Durotwin
Series 963
Rockwell/Rockwell Superficial
Type Hardness Testing
Machine
Sturdy and easy-to-operate.
• Economic type
• Non-motorized oil dash pot control
• Automatic zero device
• Minimum graduation:
Rockwell 0.5HR
Rockwell Superficial 1 HR
• For Rockwell Hardness Scales A-D-C-F-B-G
• For Rockwell Superficial Hardness
15N-30N-15T-30T and 45T
and others with optional accessories
• Wide range of optional accessories
963-102R
STANDARD ACCESSORIES
• Diamond indenter.
• 1/16” dia. steel ball indenter.
• 1/16” dia. spare steel ball (5 pcs.).
• Flat anvil diameter: 2.52” (64mm).
• Hardness test block (60 to 65HRC),
(90 to 95HRB), (60 to 65HR30N).
• Machine cover.
• User’s manual.
• Level.
• Accessories box.
• “V” anvil.
Specifications
Model DT10
Order No. 963-102R
Preliminary test force 98.07N (10kgf), 29.42 (3kgf)
Test force 588.4N (60kgf), 980.7N (100kgf), 1471N (150kgf),
147.1N (15kgf), 294.2N (30kgf), 588.4N (45kfg)
Table up/down drive Manual
Load duration Manual
Display Dial
Minimum graduation 0.5 (Rockwell Each)
1 (Rockwell superficial)
Maximum height 4” (105mm) with spindle cover
6.69” (170mm) without spindle cover
Maximum depth 6.10” (155mm)
Dimensions (W x D x H) 7.48” x 20.87” x 27.76”
(190mm x 530mm x 705mm)
Mass 97 lbs. (44kg)
H-12
H-13 (2003) full size 12/8/03 8:49 PM Page 1
MEASURING INSTRUMENTS
Optional Accessories
Micro-Vickers/Vickers Hardness Testing Machine
Indenters Test Blocks
Order No. Type Model Order No. Description Load
19BAA061 Knoop Indenter MVK-E3. G1, VL 64BAA173 Vickers 100HV Test Block 100gf
19BAA058 Vickers Indenter H, HM Standard Series 64BAA174 Vickers 200HV Test Block 100gf
19BAA062 Knoop Indenter MVK-G2, G3
64BAA175 Vickers 300HV Test Block 100gf
19BAA059 Vickers Indenter MVK-H2, H3, HM114
64BAA176 Vickers 400HV Test Block 100gf
19BAA060 Vickers Indenter HV, AVK-C Series
64BAA177 Vickers 500HV Test Block 100gf
Universal 64BAA178 Vickers 600HV Test Block 100gf
Bulbs
Specimen Holder 64BAA179 Vickers 700HV Test Block 100gf
Order No. Description
513667 Bulb, 12v/50w, halogen double pin type, 64BAA180 Vickers 800HV Test Block 100gf
HM series with box style illuminators. 64BAA181 Vickers 900HV Test Block 100gf
19BAA219 Bulb, 12v/50w, halogen double pin type, 64BAA182 Vickers 100HV Test Block 500gf
Later H series
64BAA183 Vickers 200HV Test Block 500gf
19BAA095 Bulb, 6v/20w, halogen bayonet type, all
E, G and early H series testers. 64BAA184 Vickers 300HV Test Block 500gf
Used to secure a specimen, 64BAA185 Vickers 400HV Test Block 500gf
that has a measuring surface 64BAA186 Vickers 500HV Test Block 500gf
that is hard to stabilize, perpen-
dicular to the indenter axis. 64BAA187 Vickers 600HV Test Block 500gf
810-020
64BAA188 Vickers 700HV Test Block 500gf
64BAA189 Vickers 800HV Test Block 500gf
Round tables 64BAA190 Vickers 900HV Test Block 500gf
50x50mm-travel
stage 64BAA191 Vickers 100HV Test Block 1000gf
64BAA192 Vickers 200HV Test Block 1000gf
64BAA193 Vickers 300HV Test Block 1000gf
64BAA194 Vickers 400HV Test Block 1000gf
Dimensions: 8"(203mm) 64BAA195 Vickers 500HV Test Block 1000gf
Dimensions: 4.92x4.92"(125x125mm) 810-037-7
Minimum reading: 0.01mm 64BAA196 Vickers 600HV Test Block 1000gf
810-012
Specimen (thin plate) 64BAA197 Vickers 700HV Test Block 1000gf
holder 64BAA198 Vickers 800HV Test Block 1000gf
Clamping devices 64BAA199 Vickers 900HV Test Block 1000gf
(Vises) 64BAA200 Knoop 200HK Test Block 100gf
64BAA201 Knoop 300HK Test Block 100gf
Secures a plate with a thickness of 64BAA202 Knoop 400HK Test Block 100gf
.197"(5mm) or less, or foil-like speci- 64BAA203 Knoop 500HK Test Block 100gf
mens.
Vise 810-013 64BAA204 Knoop 600HK Test Block 100gf
Max. opening: 1.77"(45mm)
Standard for the MH series.
64BAA205 Knoop 700HK Test Block 100gf
Specimen (wire) holder
810-016 64BAA206 Knoop 800HK Test Block 100gf
64BAA207 Knoop 250HK Test Block 500gf
64BAA208 Knoop 300HK Test Block 500gf
64BAA209 Knoop 400HK Test Block 500gf
64BAA210 Knoop 500HK Test Block 500gf
Vise Used to horizontally secure a wire or
needle specimen that has a diameter 64BAA211 Knoop 600HK Test Block 500gf
Max. opening: 3.94"(100mm)
810-017 of .126"(3.2mm) or less. 64BAA212 Knoop 700HK Test Block 500gf
810-014
64BAA213 Knoop 800HK Test Block 500gf
Specimen (wire or 64BAA214 Knoop 250HK Test Block 1000gf
Rotary table ball) holder 64BAA215 Knoop 300HK Test Block 1000gf
64BAA216 Knoop 400HK Test Block 1000gf
64BAA217 Knoop 500HK Test Block 1000gf
64BAA218 Knoop 600HK Test Block 1000gf
Used to rotate a specimen. Used to vertically secure a wire or 64BAA219 Knoop 700HK Test Block 1000gf
Graduated in 1° increments. ball specimen that has a diameter of
810-018 .126"(3.2mm) or less. 64BAA220 Knoop 800HK Test Block 1000gf
810-015
H-13
H-14 (2003) full size 12/8/03 8:50 PM Page 1
MEASURING INSTRUMENTS
Durometer Digital/Analog
Series 811
811-335 811-336
811-337 811-338
811-331 811-332
811-333 811-334
Features
• Durometers are suitable for testing natural rubber, neoprene, • The analog durometer is provided with a peak retaining hand
polyesters, P.V.C., leather, thiokol, nitril, rubber, wax, vinyl, cel- for error-free reading.
lulose acetates, glass, polystyrol, and other materials. • The digital durometer is provided with data hold function, and
• Mitutoyo's Durometers are manufactured in accordance with permits the operator to make an error-free reading on the clear
ASTM D 2240, ISO 868, ISO 7619, DIN 53 505, JIS K 6253, LCD screen. Data output function.
and JIS K 7215 specifications.
• Units are available in both Shore A and Shore D scales, and
will test a wide variety of applications.
Specifications
Order No. 811-331 811-332 811-333 811-334 811-335 811-336 811-337 811-338
Model HH-331 HH-332 HH-333 HH-334 HH-335 HH-336 HH-337 HH-338
Scale Shore A Shore D Shore A Shore D
Display Analog Digital Analog Digital Analog Digital Analog Digital
Graduation 1 0.5 1 0.5 1 0.5 1 0.5
Range 10~90 20~90 10~90 20~90
Standards JIS K 6253, JIS K 7215, ASTM D 2240 JIS K 6253, JIS K 7215, ASTM D 2240
ISO 868, ISO 7619, DIN 53 505 ISO 868, ISO 7619, DIN 53 505
Location
Area .71" DIA. (18mm DIA.) 1.73 x .71" (44 x 18mm)
Indenter Blunt Taper Sharp Point Blunt Taper Sharp Point
Tip Angle 35° ± 0.25° 30° ± 1° 35° ± 0.25° 30° ± 1°
Function Peak- On/Zero Peak- On/Zero Peak- On/Zero Peak- On/Zero
Retaining Off Retaining Off Retaining Off Retaining Off
Hand Data/Hold Hand Data/Hold Hand Data/Hold Hand Data/Hold
SPC Output SPC Output SPC Output SPC Output
Dimension
7.09 x 2.56 x 1.97" (195 x 60 x 30mm) 3.94 x 2.56 x 1.38" (150 x 60 x 30mm)
HxWxD
Mass .7 lbs. (320g) .64 lbs. (290g)
H-14
H-15 (2003) full size 12/8/03 8:51 PM Page 1
MEASURING INSTRUMENTS
Durometer Digital/Analog
Series 811
64AAA964
64AAA963
Optional Accessories
19BAA180 Holding Bar 64AAA962 "A" Scale Durometer Stand
64AAA964 Calibration Set (Shore A Scale) 64AAA794 "A" Scale Durometer Stand with Air Damper
Test Block 30* DURO (Blue) 64AAA796 Combination "D" & "A" Scale Durometer Stand
Test Block 60* DURO (Yellow) 64AAA963 O-Ring Fixture Set
Test Block 90* DURO (Gray) 1/16", 3/32", 1/8", 3/16" and 1/4"
Mahogany Box O-Ring cross sections
* Values shown are nominal only 264-503AS2 Digimatic Miniprocessor
Test Block Size 2" x 2" x 1/4" 905693 Connecting Cable 40" (1m) for
64AAA590 "D" Scale Test Block Set Durometer and Digimatic Miniprocessor
Holding Bar
The holding bar is used to mount a
Durometer on a drill press.
64AAA796
264-503AS2
H-15
H-16 (2003) full size 12/8/03 8:52 PM Page 1
MEASURING INSTRUMENTS
Hardmatic
HH-110/120/140
HH-140
ANALOG TESTER
HH-120 HH-110
OPTIONAL ACCESSORIES
Features HH-120/140
HH-120/140. Portable Digital Hardness Testers Order No. Description
64BAA221 Diamond Indenter
• Any of five hardness values 19BAA189 Cylindrical Specimen Support
Brinell Hardness (HB), Vickers Hardness (HV), Rockwell ø1.96", "V" width 1.18"/150°
Hardness (HRC, HRB), Shore Hardness (HS). 19BAA194 Step Specimen Support ø1.5",
.35" step
Tensile strength (N/mm2) 937386 SPC Cable
• 450 Measurement Memory Storage.
• RS-232 & SPC output for use with external printer or PC.
• HH-140 test head can be installed on a testing fixture for
rapid inspection of small parts.
Cylinder Step
Specimen Support Specimen Support
19BAA189 19BAA194
Specifications
Model
Order No.
Display (LCD)
HH-120
810-263A
One-unit type
HH-140
810-264A
Separate type
Hardmatic Analog
Measuring range
Vickers 20 to 999HV for hard specimen.
Tester HH-110
(Hardness increment: 1) 20 to 999HV for soft specimen. Order No. 810-502 US to SAE handbook
Brinell 81 to 767HB for hard specimen.
1949-ASTM
(Hardness increment: 1) 42 to 169HB for soft specimen.
Rockwell B 41.0 to 110.0HRB for hard specimen. Features
(Hardness increment: 0.1) 10.0 to 93.5HRB for soft specimen.
• Range of models are available.
Rockwell C
0.0 to 68.0HRC for hard specimen.
(Hardness increment: 0.1) • Easy to use and read.
Shore 14.0 to 98.0HS for hard specimen. • Rockwell C, B, & A scale testing.
(Hardness increment: 0.1) 7.6 to 30.2HS for soft specimen.
Tensile Strength • Efficient, accurate measurement.
390 to 1999N/mm2 for hard specimen.
(Hardness increment: 1) • Simple calibration and anvil changing.
Operating pressure Approx. 15kgf Model 810-502
Indenter Diamond 100° conical • Monocrystal Diamond Indenter. Rockwell A 40-85HRA
Output RS-232C, SPC Rockwell B 50-100HRB
Rockwell C 20-70HRC
Power Supply Via AC adapter or battery (9V DC)
Dimensions (WxDxH) OPTIONAL ACCESSORIES
Measuring Unit: 5.35x3.78x5.20" 5.35x3.27x2.36" HH-110
(136x96x132mm) (136x83x60mm) Order No. Description
Display Unit: –– 3.54x5.04x1.97" 60BAA001 Diamond Indenter
(90x128x50mm) 60BAA006 "V"-Base
Mass 60BAA011 Large "V"-Base ø2.48", "V" width 2.34"/165°
Measuring Unit: 2.64 lbs. (1.2kg) 1.76 lbs. (0.8kg) 60BAA012 Small "V"-Base ø2.48", "V" width .59"/120°
Display Unit: –– 1.1 lbs. (0.5kg) 60BAA013 Narrow Base Width 1.1", "V" width .59"/120°
H-16
H-17 (2003) full size 12/8/03 8:53 PM Page 1
MEASURING INSTRUMENTS
Hardmatic
HH-401
Series 810
Rebound Type Portable Hardness Tester
Features
• Digital readout from L-values to HRC - HRB - HL - HV - HB -
HS scales.
• Memory 900 data.
• High and low limits OK/NG.
• Outputs to RS-232C, SPC.
• Battery powered.
• Conforms to ASTMA956.
H-17
H-18 (2003) full size 12/8/03 8:55 PM Page 1
MEASURING INSTRUMENTS
10 mm ball
N Diamond
N Diamond
N Diamond
10mm ball
lbs/sq. in.
1/16" ball
1/16" ball
1/16" ball
1/16" ball
1/16" ball
1/16" ball
lbs/sq. in.
Diamond
1/16" ball
Diamond
Diamond
Diamond
1/8" ball
1/8" ball
1/8" ball
3000 kg
1000 kg
Vickers
3000 kg
1000 kg
500 gm
& over
500 gm
100 kg
150 kg
100 kg
150 kg
500 kg
& over
150 kg
100 kg
150 kg
60 kg
15 kg
30 kg
45 kg
60 kg
60 kg
10 kg
10 kg
60 kg
15 kg
30 kg
The conversion values are approximate values only. They have been Continued on next page.
independently developed and appear to be consistent with ASTM E-140 and A-370.
H-18
H-19 (2003) full size 12/8/03 8:55 PM Page 1
MEASURING INSTRUMENTS
10 mm ball
lbs/sq. in.
1/16" ball
1/16" ball
1/16" ball
1/16" ball
1/16" ball
1/16" ball
Diamond
1/8" ball
1/8" ball
1/8" ball
3000 kg
1000 kg
Thickness
500 gm
& over
100 kg
150 kg
100 kg
150 kg
500 kg
60 kg
15 kg
30 kg
45 kg
60 kg
60 kg
10 kg
inches (mm) 15N 30N 45N A D C
39 79.1 NA 73.3 42.3 11.6 80.0 NA 54.5 30.3 96 74 NA NA .006 (0.15) 92 • • • • •
38 78.6 NA 73.0 41.6 10.6 79.5 NA 54.0 29.9 95 73 NA NA .008 (0.20) 90 • • • • •
37 78.0 NA 72.7 41.0 9.6 79.0 NA 53.0 29.5 94 72 NA NA .010 (0.25) 88 • • • • •
36 77.4 NA 72.3 40.3 8.6 78.5 100 52.0 29.1 93 72 NA NA .012 (0.30) 83 82 77 • • •
35 76.9 NA 72.0 39.6 7.6 78.0 99.5 51.5 28.7 92 71 NA NA .014 (0.36) 76 78.5 74 • • •
34 76.3 NA 71.7 39.0 6.6 77.0 99.0 50.5 28.2 91 70 NA NA .016 (0.41) 68 74 72 86 • •
33 75.7 NA 71.4 38.3 5.6 76.5 98.8 49.5 27.8 90 69 NA NA .018 (0.46) √ 66 68 84 0 9
32 75.2 NA 71.0 37.6 4.6 76.0 98.5 48.5 27.4 89 69 NA NA .020 (0.51) √ 57 63 82 77 0
31 74.6 NA 70.7 37.0 3.6 75.5 98.0 48.0 27.0 88 68 NA NA .022 (0.56) √ 47 58 79 75 69
30 74.0 NA 70.4 36.3 2.6 75.0 97.8 47.0 26.6 87 67 NA NA .024 (0.61) √ √ 51 76 72 67
29 73.5 NA 70.0 35.6 1.0 74.0 97.5 46.0 26.0 87 66 NA NA .026 (0.66) √ √ 37 71 68 65
28 73.0 NA 69.3 34.5 NA 73.5 97.0 45.0 25.5 86 66 NA NA .028 (0.71) √ √ 20 67 63 62
27 72.5 NA 69.0 33.0 NA 73.0 96.5 44.5 25.0 85 65 NA NA .030 (0.76) √ √ √ 60 58 57
26 71.0 NA 68.8 32.5 NA 72.5 96.3 43.5 24.5 84 65 NA NA .032 (0.81) √ √ √ √ 51 52
25 71.0 NA 68.8 32.5 NA 72.0 96.0 42.5 24.3 83 64 NA NA .034 (0.86) √ √ √ √ 43 45
24 70.5 NA 68.5 32.0 NA 71.0 95.5 41.5 24.0 82 64 NA NA .036 (0.91) √ √ √ √ √ 37
23 70.0 NA 68.0 31.0 NA 70.5 95.3 41.0 23.5 82 63 NA NA .038 (0.96) √ √ √ √ √ 28
22 69.5 NA 67.8 30.5 NA 70.0 95.0 40.0 23.0 81 62 NA NA .040 (1.02) √ √ √ √ √ 20
21 69.0 NA 67.5 29.5 NA 69.5 94.5 39.0 22.5 81 62 NA NA Thicker or harder Rockwell Superficial Rockwell Regular
20 68.5 NA 67.3 29.0 NA 68.5 94.3 38.0 22.0 80 61 NA NA material can be tested. Hardness Scales Hardness Scales
19 68.0 NA 67.0 28.5 NA 68.0 94.0 37.5 21.5 79 61 NA NA Thickness
18 67.0 NA 66.5 27.5 NA 67.5 93.5 36.5 21.3 78 60 NA NA inches (mm) 15T 30T 45T F B G
17 66.5 NA 66.3 27.0 NA 67.0 93.0 35.5 21.0 78 60 NA NA
16 66.0 NA 66.0 26.0 NA 66.5 92.8 35.0 20.5 77 59 NA NA .010 (0.25) 91 • • • • •
15 65.5 NA 65.5 25.5 NA 65.5 92.5 34.0 20.0 76 59 NA NA .012 (0.30) 86 • • • • •
14 65.0 NA 65.3 25.0 NA 65.0 92.0 33.0 NA 75 59 NA NA .014 (0.36) 81 80 • • • •
13 64.5 NA 65.0 24.0 NA 64.5 91.8 32.0 NA 75 58 NA NA .016 (0.41) 75 72 71 • • •
12 64.0 NA 64.5 23.5 NA 64.0 91.5 31.5 NA 74 58 NA NA .018 (0.46) 68 64 62 • • •
11 63.5 NA 64.3 23.0 NA 63.5 91.0 30.5 NA 73 57 NA NA .020 (0.51) √ 55 53 • • •
10 63.0 NA 64.0 22.0 NA 62.5 90.5 29.5 NA 72 57 NA NA .022 (0.56) √ 45 43 • • •
9 62.0 NA 63.8 21.5 NA 62.0 90.3 29.0 NA 71 57 NA NA .024 (0.61) √ 34 31 98 94 94
8 61.5 NA 63.5 20.5 NA 61.5 90.0 28.0 NA 71 56 NA NA .026 (0.66) √ √ 18 91 87 87
7 61.0 NA 63.0 20.0 NA 61.0 89.5 27.0 NA 70 56 NA NA .028 (0.71) √ √ 4 85 80 76
6 60.5 NA 62.8 19.5 NA 60.5 89.3 26.0 NA 69 55 NA NA .030 (0.76) √ √ √ 77 71 68
5 60.0 NA 62.5 18.5 NA 60.0 89.0 25.5 NA 69 55 NA NA .032 (0.81) √ √ √ 69 62 59
4 59.5 NA 62.0 18.0 NA 59.0 88.5 24.5 NA 69 55 NA NA .034 (0.86) √ √ √ √ 52 50
3 59.0 NA 61.8 17.0 NA 58.5 88.0 23.5 NA 68 54 NA NA .036 (0.91) √ √ √ √ 40 42
2 58.0 NA 61.5 16.5 NA 58.0 87.8 23.0 NA 68 54 NA NA .038 (0.96) √ √ √ √ 28 31
1 57.5 NA 61.0 16.0 NA 57.5 87.5 22.0 NA 63 54 NA NA .040 (1.02) √ √ √ √ √ 22
0 57.0 NA 60.5 15.0 NA 57.0 87.0 21.0 NA 67 53 NA NA √ - Can be tested - no minimum hardness.
The conversion values are approximate values only. They have been
independently developed and appear to be consistent with ASTM E-140 and A-370.
H-19
I-01 (2003) full size 12/11/03 3:51 PM Page 1
ORDER NUMBER
Code No. Range (L0) L1 L2 L3 Middle Support Number Cable Length
(Mounting Pitch)
539-801 4"/100mm 4.72"/120mm 10.16"/258mm 10.94"/278mm 11.48'/3.5m
539-802 6"/150mm 6.69"/170mm 12.13"/308mm 12.91"/328mm 11.48'/3.5m
539-803 8"/200mm 8.69"/220mm 14.09"/358mm 14.88"/378mm 11.48'/3.5m
539-804 10"/250mm 10.63"/270mm 16.06"/408mm 16.85"/428mm 11.48'/3.5m
539-805 12"/300mm 12.99"/330mm 18.43"/468mm 19.21"/488mm 11.48'/3.5m
539-806 14"/350mm 14.96"/380mm 20.39"/518mm 21.18"/538mm 11.48'/3.5m
539-807 16"/400mm 16.93"/430mm 22.36"/568mm 23.15"/588mm 11.48'/3.5m
539-808 18"/450mm 18.90"/480mm 24.33"/618mm 25.12"/638mm 11.48'/3.5m
539-809 20"/500mm 21.26"/540mm 26.69"/678mm 27.48"/698mm 1 11.48'/3.5m
539-811 24"/600mm 25.20"/640mm 30.63"/778mm 31.42"/798mm 1 11.48'/3.5m
539-813 28"/700mm 29.13"/740mm 34.57"/878mm 35.35"/898mm 1 11.48'/3.5m
539-814 30"/750mm 30.71"/780mm 36.14"/918mm 36.93"/938mm 1 11.48'/3.5m
539-815 32"/800mm 33.07"/840mm 38.50"/978mm 39.29"/998mm 1 11.48'/3.5m
539-816 36"/900mm 37.07"/940mm 42.44"/1078mm 43.23"/1098mm 1 11.48'/3.5m
539-817 40"/1000mm 40.94"/1040mm 46.38"/1178mm 47.17"/1198mm 1 16.40'/5m
539-818 44"/1100mm 44.88"/1140mm 50.31"/1278mm 51.10"/1298mm 2(16.93"/430mm) 16.40'/5m
539-819 48"/1200mm 48.82"/1240mm 54.25"/1378mm 55.04"/1398mm 2(18.11"/460mm) 16.40'/5m
539-820 52"/1300mm 52.76"/1340mm 58.19"/1478mm 58.98"/1498mm 2(19.29"/490mm) 16.40'/5m
539-821 56"/1400mm 56.69"/1440mm 62.13"/1578mm 62.91"/1598mm 2(20.87"/530mm) 16.40'/5m
539-822 60"/1500mm 60.63"/1540mm 66.06"/1678mm 66.85"/1698mm 2(22.05"/560mm) 16.40'/5m
539-823 64"/1600mm 64.57"/1640mm 70.00"/1778mm 70.79"/1798mm 3(8.46"/215mm) 16.40'/5m
539-824 68"/1700mm 68.50"/1740mm 73.94"/1878mm 74.72"/1898mm 3(9.06"/230mm) 16.40'/5m
539-825 72"/1800mm 72.44"/1840mm 77.87"/1978mm 78.66"/1998mm 3(11.03"/280mm) 16.40'/5m
I-2
I-03 (2003) full size 12/8/03 9:05 PM Page 1
AT715 Schematic
I-3
I-04 (2003) full size 12/8/03 9:06 PM Page 1
Linear Scale
APPLICATIONS
Machine Tools
Semiconductor Manufacturing
Inserting Machine
I-4
I-05 (2003) full size 12/8/03 9:07 PM Page 1
I-5
I-06 (2003) full size 12/8/03 9:08 PM Page 1
AT2-N
AT2
09AAA207 All KS, KC, UDR Series Counters
09AAA207 09AAA198
AT11-N (with six pin connectors)
AT11
For all .0001"
Resolution Counters
AT102 09AAA181 With Seven Pin
Connectors
APL Counter
AT111 09AAA181V* 164-660*, 164-661*, 164-662*
MPK-2L
983-352
For all .0005"
AT112 Resolution Counters
09AAA198 With Six Pin
Connectors
APL Counter
AT181 09AAA198V* 164-660*, 164-661*, 164-662*, 164-563, 164-664, 164-665
PL & PL Zero Output Counter
164-252A, 164-254A, 164-254A, 164-295A
*NOTE! V=VERTICAL TYPE
(WHEN ONLY RE-PLACING ONE SCALE, YOU CAN USE EITHER, HORIZ.,
OR VERT. TYPE ADAPTER)
I-6
I-07 (2003) full size 12/8/03 9:23 PM Page 1
Signal cable
An armored signal cable is used to connect the scale
unit to the display unit.
AT111 Slim Spars Waterproof detecting head and flexible
Range: 4" (100mm) - 60" (1500mm) cable connection
The detecting head of the AT102 is made waterproof
by an O-ring, allowing it to withstand splashes of cut-
ting fluid, etc. The signal cable outlet can be positioned
on either side of the head so the signal cable can be
connected from either direction.
The detector of each scale unit consists of a light source (LED) and a
photoelectric device (phototransistor) which face each other with the
same scale and index scale between them. When the main scale
moves, relative to the index scale, the quantity of light that is transmit-
ted through the gratings on the index scale varies with the same peri-
od as the grating pitch. This variation of light intensity is converted
For further information request into electrical signals and output as two-phase (A and B) waves with
a phase difference of 90°. The display unit divides these signals to
Bulletin No. 1673 determine the direction of the scale movement, and digitally displays
the displacement of the scale.
I-7
I-08 (2003) full size 12/8/03 9:09 PM Page 1
Linear Scales
AT-115 AT-112 AT-111
Series 539 Series 539 Series 539
Standard Type Scale Unit Ultra Slim Type Scale Unit Standard Type Scale Unit
Specifications Specifications Specifications
Inch/Metric Inch/Metric Inch/Metric
Order No. S accuracy Order No. S accuracy H accuracy Order No. S accuracy H accuracy
Range(Lo) (5+5Lo/1000)µm Range(Lo) (5+5Lo/1000)µm (3+3Lo/1000)µm Range(Lo) (5+5Lo/1000)µm (3+3Lo/1000)µm
4”/100mm 539-271 1.5”/50mm 539-251 539-251-10 4”/100mm 539-201 539-201-10
6”/150mm 539-272 2.5“/70mm 539-252 539-252-10 6”/150mm 539-202 539-202-10
8”/200mm 539-273 4.5”/120mm 539-253 539-253-10 8”/200mm 539-203 539-203-10
10”/250mm 539-274 6.5”/170mm 539-254 539-254-10 10”/250mm 539-204 539-204-10
12”/300mm 539-275 8.5”/220mm 539-255 539-255-10 12”/300mm 539-205 539-205-10
14”/350mm 539-276 10.5”/270mm 539-256 539-256-10 14”/350mm 539-206 539-206-10
16”/400mm 539-277 12.5”/320mm 539-257 539-257-10 16”/400mm 539-207 539-207-10
18”/450mm 539-278 14.5”/370mm 539-258 539-258-10 18”/450mm 539-208 539-208-10
20”/500mm 539-279 16.5”/420mm 539-259 539-259-10 20”/500mm 539-209 539-209-10
24”/600mm 539-281 18.5”/470mm 539-260 539-260-10 24”/600mm 539-211 539-211-10
28”/700mm 539-283 20.0”/520mm 539-261 539-261-10 28”/700mm 539-213 539-213-10
30”/750mm 539-284 22.0”/570mm 539-262 539-262-10 30”/750mm 539-214 539-214-10
32”/800mm 539-285 24.0”/620mm 539-263 539-263-10 32”/800mm 539-215 539-215-10
36”/900mm 539-286 26.0”/670mm 539-264 539-264-10 36”/900mm 539-216 539-216-10
40”/1000mm 539-287 28.0”/720mm 539-265 539-265-10 40”/1000mm 539-217 539-217-10
44”/1100mm 539-288 30.0”/770mm 539-266 539-266-10 44”/1100mm 539-218 539-218-10
48”/1200mm 539-289 32.0”/820mm 539-267 539-267-10 48”/1200mm 539-219 539-219-10
52”/1300mm 539-290 36.0”/920mm 539-268 539-268-10 52”/1300mm 539-220 539-220-10
56”/1400mm 539-291 40.0”/1020mm 539-269 539-269-10 56”/1400mm 539-221 539-221-10
60”/1500mm 539-292 A 9.8 feet signal cable is provided. Signal cable for 60”/1500mm 539-222 539-222-10
Spacer set 538885K. AT102/111/112/181 09AAA030A-3(m), 09AAA030B-5(m) A signal cable is provided. The cable length depends on the
size of the Linear Scale. 9.8 feet for range 4-36”, 16.4 feet
for range 40-60”.
AT-102 Spacer set 538885K.
Series 539
Standard Type Scale Unit AT-181
Specifications Series 539
Inch/Metric Plunger Type Scale Unit
Order No. S accuracy H accuracy S accuracy
Range(Lo) (5+5Lo/1000)µm (3+3Lo/1000)µm Range(Lo) (5+8Lo/1000)µm Specifications
4”/100mm 539-111 539-111-10 88”/2200mm 539-137 Inch/Metric
6”/150mm 539-112 539-112-10 96”/2400mm 539-138 Order No. S accuracy H accuracy
8”/200mm 539-113 539-113-10 100”/2500mm 539-139 Range(Lo) (5+5Lo/1000)µm (3+3Lo/1000)µm
10”/250mm 539-114 539-114-10 104”/2600mm 539-140 4”/100mm 539-301 539-301-10
12”/300mm 539-115 539-115-10 112”/2800mm 539-141 6”/150mm 539-302 539-302-10
14”/350mm 539-116 539-116-10 120”/3000mm 539-142 8”/200mm 539-303 539-303-10
16”/400mm 539-117 539-117-10 130”/3250mm 539-143 10”/250mm 539-304 539-304-10
18”/450mm 539-118 539-118-10 140”/3500mm 539-144 12”/300mm 539-305 539-305-10
20”/500mm 539-119 539-119-10 150”/3750mm 539-145 14”/350mm 539-306 539-306-10
24”/600mm 539-121 539-121-10 160”/4000mm 539-146 16”/400mm 539-307 539-307-10
28”/700mm 539-123 539-123-10 170”/4250mm 539-147 18”/450mm 539-308 539-308-10
30”/750mm 539-124 539-124-10 180”/4500mm 539-148 20”/500mm 539-309 539-309-10
32”/800mm 539-125 539-125-10 190”/4750mm 539-149 22"/550mm 539-310 539-310-10
36”/900mm 539-126 539-126-10 200”/5000mm 539-150 24”/600mm 539-311 539-311-10
40”/1000mm 539-127 539-127-10 210”/5250mm 539-151 A 9.8 feet cable is provided.
44”/1100mm 539-128 539-128-10 220”/5500mm 539-152
48”/1200mm 539-129 539-129-10 230”/5750mm 539-153
52”/1300mm 539-130 539-130-10 240”/6000mm 539-154
56”/1400mm 539-131 539-131-10
60”/1500mm 539-132 539-132-10
64”/1600mm 539-133 539-133-10
68”/1700mm 539-134 539-134-10
72”/1800mm 539-135 539-135-10
80”/2000mm 539-136 539-136-10
A signal cable is provided. The cable length depends on the size of the Linear Scale.
9.8 feet for range 4-36”,16.4” feet for range 40-88”, 23 feet for range 96-120”,
32.8 feet for range 130-180”, 49.2 feet for range 190-240”.
Spacer set 544129K.
I-8
I-09 (2003) full size 12/15/03 10:20 AM Page 1
Mitutoyo’s new Digital Readout (DRO) System integrates the AT100 series
Linear Scale with K-Series counters, this system offers accurate detection
and display of axial displayment of machine tools and measuring equipment.
The DRO system can be configured to best meet your application, such as
turning, milling, or grinding. Choose a suitable combination of scale unit and
display unit.
KA COUNTER
Specifications
KA Counter
Order No. Axis Standard High Scale Unit
Resolution Resolution
174-173A 2 .001"/.0005"/.0002"/.0001"/.00005" .0001"/.00005"/.00002"/.00001"/.000005" AT102, AT111, AT112,
(0.010/0.005/0.002/0.001mm): (0.0010/0.0005/0.0002/0.0001mm): AT115, AT181 (AT2N,
When connecting AT715 and AT100 Series When connecting AT100 Series AT11N with Adapters)
174-173A 3 .002"/.0010"/.0005"/.0004"/.0002"/.0001" .0002"/.00010"/.00005"/.00004"/.00002"/.000010" AT715
(0.020/0.010/0.004/0.002mm): (0.0020/0.0010/0.0004/0.0002mm):
When connecting AT715 and AT100 Series (Dia.) When connecting AT100 Series (Dia.)
KC COUNTER
KC Counters
Order No. Axis Resolution* Scale Unit
inch mm
174-122A 1 .00002" .0005" 0.0005mm AT102, AT111, AT112,
174-124A 2 .00005" .0010" 0.001mm AT115, AT181 (AT2N,
174-126A 3 .0001" 0.002mm AT11N with Adapters)
.0002" 0.005mm
0.010mm
*Resolution is selectable
Not connectable to AT715 Linear Scale.
I-9
I-10 (2003) full size 12/9/03 9:39 AM Page 1
FUNCTIONS
ZERO Zero setting ● ●
Y
X
Zero-set remote controller ●
P.SET Preset ● ●
0.001
/ 0.01
Resolution setting ● +1
●+1
Touch-signal probe ● ●
SET Scale reference point setting ● +6
●+6
+ Addition/Subtraction ●
DIA Diameter display ● ●
Z1+Z2 Addition of 2-scale data ● +4
●+4
I-10
I-11 (2003) full size 12/8/03 9:12 PM Page 1
PSU-200
Pulse signal conversion interface
Features
• +5VDC external power supply.
• Applicable with Linear Scales with the sinusoidal signal output.
• Quadrature signal output (conforming to EIA standard RS422-A).
• Alarm function for detecting broken wires or short circuits in the
detector, over-speed and fluctuation errors in the input signal from
the detector.
• LED indications
Origin signal input
Alarm for power supply (voltage drop and noise)
• DIP switch functions
Direction switching
Mode switching (high impedance/alarm signal output)
Division selection (4/8/10/20/40/80/100/200)
Min. edge interval selection (1000/500/250/125/62.5ns)
TECHNICAL DATA
Code No. 539-005
Number of axes 1 axis
Number of deviation 4, 8, 10, 20, 40, 80, 100 or 200 (switchable)
Functions Division setting:
4/8/10/20/40/80/100/200
Min. edge interval setting:
1000/500/250/125/62.5ns
Direction switching
LED for alarm indication:
Broken wires and short circuits in the
scale, abnormal signal, overspeed
Alarm output mode switching:
High impedance output/alarm signal output
External alarm reset (photocoupler input)
LED for origin detection
LED for low-level power supply voltage warning
Power supply 5VDC±5% on the power terminal
Consumption 200mA (except the scale)
Operating temperature 0°C to 40°C
Mass Approx. 1.4 lbs (620g)
I-11
I-12 (2003) full size 12/8/03 9:12 PM Page 1
PSU-200
Pulse signal conversion interface
A Vpp = 2V RS422
A
B
B
øA V p-p
PB
V OH = 2.5V (min.)
td, d V OL = 0.5V (max.)
td: Edge interval
d: Resolution
øB V ref PZ
Z-phase
pulse width
GND (20±10mm) The Z-phase pulse width depends
V ref = 2.5V on the Linear Scale connected.
V p-p = 2V PZ (This is for AT100 series Linear Scale.)
I-12
I-13 (2003) full size 12/8/03 9:13 PM Page 1
Specifications
Scale Graduation 20µm
Material Glass Thermal expansion coefficient:
8x10-6/°C
Mounting method* End or Frame
Accuracy (at 20°C) (3+3L0/1000)µm or (2+2L0/1000)µm (up
to 500mm)
Output Signal A/B quadrature with resolutions specified
below Scale reference point
Alarm signal
Effective range* 100 to 500mm (50mm step), 600, 700,
750, or 800 to 1500mm (100mm step).
Resolution* 0.1µm, 0.2µm, 0.5µm, 1µm, 2.5µm, 5µm
Min. edge interval* 125ns, 250ns, 333ns, 500ns or 1000ns
Max. response speed* 120m/min (depending on the choice of
resolution and edge interval).
Cable* Head cable Choice of length, with or w/o metal cover For further information request
and signal cable connector. Bulletin No. US4189-539, 579
Operating temperature 0°C to 45°C
*Selectable for factory-setting
NOTE: When ordering, please refer to page I-18
I-13
I-14 (2003) full size 12/8/03 9:14 PM Page 1
Specifications
Scale Graduation 20µm Code No. Description Code No. Description
Materials Glass Thermal expansion coefficient: 539-501 AT332–4" 539-518 AT332–44"
(8±1)x10-6/°C
Detecting method Electrostatic capacitance/photoelectric 539-502 AT332–6" 539-519 AT332–48"
type 539-503 AT332–8" 539-520 AT332–52"
Mounting method End blocks 539-504 AT332–10" 539-521 AT332–56"
Accuracy (at 20°C) Up to 1500mm: (3+3L0/1000)µm
Over 1500mm: (5+5L0/1000)µm
539-505 AT332–12" 539-522 AT332–60"
Output interface FANUC NC controller interface 539-506 AT332–14" 539-523 AT332–64"
Output method Differential line driver 539-507 AT332–16" 539-524 AT332–68"
Main signal output pitch 2µm
539-508 AT332–18" 539-525 AT332–72"
Effective range 100 to 3000mm (20 models)
Resolution 0.5µm 539-509 AT332–20" 539-526 AT332–80"
Max. response speed 1.83m/sec (110m/min) 539-511 AT332–24" 539-527 AT332–88"
Supply current 300mA (max) 539-513 AT332–28" 539-528 AT332–96"
Power supplyDC5V (±5%)
Operation temperature 0°C to 45°C 539-514 AT332–30" 539-529 AT332–100"
Storage temperature -20°C to 70°C 539-515 AT332–32" 539-530 AT332–104"
539-516 AT332–36" 539-531 AT332–112"
539-517 AT332–40" 539-532 AT332–120"
I-14
I-15 (2003) full size 12/8/03 9:15 PM Page 1
Specifications
Scale Graduation 20µm Code No. Description Code No. Description
Materials Glass Thermal expansion coefficient:
539-541-30 AT353–4" 539-558-30 AT353–44"
(8±1)x10-6/°C
Detecting method Electrostatic capacitance/photoelectric 539-542-30 AT353–6" 539-559-30 AT353–48"
type 539-543-30 AT353–8" 539-560-30 AT353–52"
Mounting method Frame
539-544-30 AT353–10" 539-561-30 AT353–56"
Accuracy (at 20°C) Up to 1500mm: (3+3L0/1000)µm
Over 1500mm: (5+5L0/1000)µm 539-545-30 AT353–12" 539-562-30 AT353–60"
Output signal Absolute position serial data with 539-546-30 AT353–14" 539-563-30 AT353–64"
FANUC NC format 539-547-30 AT353–16" 539-564-30 AT353–68"
Effective range 100 to 3000mm (20 models)
Resolution 0.05µm 539-548-30 AT353–18" 539-565-30 AT353–72"
Max. response speed 2m/sec (120m/min) 539-549-30 AT353–20" 539-566-30 AT353–80"
Supply current 250mA (max) 539-551-30 AT353–24" 539-567-30 AT353–88"
Power supplyDC5V (-3% to ± 5%)
539-553-30 AT353–28" 539-568-30 AT353–96"
Operation temperature 0°C to 45°C
Storage temperature -20°C to 70°C 539-554-30 AT353–30" 539-569-30 AT353–100"
539-555-30 AT353–32" 539-570-30 AT353–104"
539-556-30 AT353–36" 539-571-30 AT353–112"
539-557-30 AT353–40" 539-572-30 AT353–120"
I-15
I-16 (2003) full size 12/8/03 9:15 PM Page 1
Features
• Good protection against harsh environment.
• Direct connection with a machine controller via a pulse
signal output (conforming to RS-422A).
Specifications
Scale Graduation 20µm
Material Glass Thermal expansion coefficient:
8x10-6/°C
Mounting method End
Accuracy (at 20°C) (3+3L0/1000)µm or (2+2L0/1000)µm (up to
500mm)
Output Signal A/B quadrature with resolutions specified
below Scale reference point
Effective range 100 to 500mm (50mm step), 600, 700,
750, or 800 to 1500mm (100mm step). Note: • Mounting dimensions are different to AT21 and AT21-C.
Resolution 0.5µm (for AT21) 1µm (for AT21C) • Signal and output connector are same as to AT21 and
Min. edge interval 1000ns (for AT21 and AT21-C) AT21-C when using SAM-10.
Max. response speed 27m/min (for AT21) 54m/min (for AT21-C)
Operating temperature 0°C to 45°C • Does not need SAM-10, direct connection with NC controller.
I-16
I-17 (2003) full size 12/17/03 9:33 AM Page 1
Specifications
Scale Graduation 8µm
Material Glass Thermal expansion coefficient:
8x10-6/°C
Accuracy (at 20°C) ±0.5µm (0 to 300mm), ±1µm (3350 to
500mm), ±2µm (600 to 1000mm)
Output Signal Two-phase sine wave with a phase differ-
ence of 90° (4µm pitch), Vpp: 2V
A/B quadrature with a phase difference of
90° (resolution: 0.1/0.05/0.2µm selec-
table), conforming to RS-422A
Scale reference point (up to 75mm: at the
center, over 100mm: at the center and
every 50mm from the center)
Alarm signal
Effective range 10 to 1000mm, refer to the back page.
Max. response speed* Two-phase sine wave:
1200mm/sec (at-3dB)
Pulse signal of 0.1µm resolution:
720mm/sec
Pulse signal of 0.05µm resolution: Code No. Description Code No. Description
360mm/sec
579-281 ST34C-.4" 579-288 ST34C-10"
Pulse signal of 0.02µm resolution:
150mm/sec 579-282 ST34C-1" 579-289 ST34C-12"
(*minimum edge interval: 125nsec) 579-283 ST34C-2" 579-290 ST34C-14"
Power supply5V±5%
579-284 ST34C-3" 579-291 ST34C-16"
Power consumption 250mA maximum
Operating temperature 0°C to 40°C 579-285 ST34C-4" 579-292 ST34C-18"
579-286 ST34C-6" 579-293 ST34C-20"
579-287 ST34C-8"
I-17
I-18 (2003) full size 12/8/03 9:17 PM Page 1
• Use the check sheet given below for the selection of Accuracy (at 20°C)
specification codes. Resolution/max. traversing speed
Counting direction
Head cable
Signal cable
Item Specification you need Code Item Specification you need Code
Effective range Lοο .4"/100mm 0100 Resolution/ 0.1µm (125ns*)/710mm/s A
6"/150mm 0150 max. traversing speed 0.1µm (250ns*)/360mm/s B
8"/200mm 0200 0.1µm (333ns*)/260mm/s C
10"/250mm 0250 0.1µm (500ns*)/180mm/s D
12"300mm 0300 0.1µm (1000ns*)/90mm/s E
14"/350mm 0350 0.2µm (125ns*)/1400mm/s F
16"/400mm 0400 0.2µm (250ns*)/710mm/s G
18"/450mm 0450 0.2µm (333ns*)/530mm/s H
20"/500mm 0500 0.2µm (500ns*)/360mm/s J
24"/600mm 0550 0.2µm (1000ns*)/180mm/s K
28"/700mm 0600 0.5µm (125ns*)/2000mm/s L
30"/750mm 0750 0.5µm (250ns*)/1800mm/s M
32"/800mm 0800 0.5µm (333ns*)/1300mm/s N
36"/900mm 0900 0.5µm (500ns*)/900mm/s P
40"/1000mm 1000 0.5µm (1000ns*)/450mm/s Q
44"/1100mm 1100 1.0µm (250ns*)/2000mm/s R
48"/1200mm 1200 1.0µm (333ns*)/2000mm/s S
52"/1300mm 1300 1.0µm (500ns*)/1800mm/s T
56"/1400mm 1400 1.0µm (1000ns*)/900mm/s U
60"/1500mm 1500 2.5µm (500ns*)/2000mm/s W
2.5µm (1000ns*)/2000mm/s X
5.0µm (1000ns*)/2000mm/s Y
Item Specification you need Code
*Edge separation assured within a range of - 10% to 0%.
Mounting method Multi-point fixing A
Double-end fixing B
Item Specification you need Code
Head cable Coil-covered cable*: 12"/0.3m A
Item Specification you need Code Normal cable*: 12"/0.3m B
Scale reference point At every 50mm interval 1 Normal cable*: 40"/1m C
At midpoint 2 Normal cable**: 120"/3m D
At the left end 3 Normal cable**: 16"/4m E
At the right end 4 Normal cable**: 200"/5m F
Normal cable**: 240"/6m G
Normal cable**: 280"/7m H
Item Specification you need Code Normal cable**: 320"/8m J
Accuracy (at 20°C) (3+3Lo/1000)µmm S Normal cable**: 360"/9m K
(2+2Lo/1000)µmm H *Provided with waterproof connector. **No connector provided.
I-18
I-19 (2003) full size 12/8/03 9:17 PM Page 1
• Use the check sheet given below for the selection of Resolution/max. traversing speed
specification codes. Counting direction
Output signal
Alarm output
Head cable
Item Specification you need Code Item Specification you need Code
Effective range Lοο .4"/10mm 0010 Counting direction Standard (PA goes ahead) 1
1"/25mm 0025 Reverse (PB goes ahead) 2
2"/50mm 0050
3"/75mm 0075
4"/100mm 0100 Item Specification you need Code
6"/150mm 0150 Output signal Sine wave and quadrature 1
8"/200mm 0200 Quadrature and reset signal 2
10"/250mm 0250
12"/300mm 0300
14"/350mm 0350
Item Specification you need Code
16"/400mm 0400
Alarm output Alarm signal S
18"/450mm 0450
High-impedance H
20"/500mm 0500
I-19
I-20 (2003) full size 12/8/03 9:18 PM Page 1
Digimatic
Scale Units
Series 572 572-210-10
With SPC Output
MITUTOYO Digimatic Scale Units can be installed on
almost any surface, offering the user precise linear
measurement capability with the added benefits of LCD
readout and output for recording data and SPC. 572-311-10
Features
• No rack, no pinion, no glass scale. Digimatic Scale is
safely embedded in the hardened stainless steel blade.
• All units come with two mounting brackets, each locat- 572-333
ed at either end of the scale.
• Battery life of approximately 2 years on smaller
models.
Remote Display
Counters 572-031A
Large, Bright LED for
Digimatic Gages with Output
Specifications
Remote Display Counter
Inch/Metric
Order No. 572-011A 572-031A
Type Single-function Multi-function
Display 6-digit, green LED
Resolution .0005"/0.01mm or .00005"/0.001mm .0005"/0.01mm or .0001"/0.01mm or .00005"/0.001mm
Functions • Zero-setting • Zero-setting
• Data output • Data output
• Miscount alarm • Miscount alarm
• Inch/mm conversion • Presetting
• GO/±NG judgment
• Direction changeover
• Inch/mm conversion
Dimensions 7.9" x 4.7" x 2.6" 9.3" x 4.8" x 2.6"
Weight 2.4 lbs. 2.9 lbs.
Power supply AC adapter (9VDC, 500mA)
*Optional accessories 936937 SPC connecting cable 1m (for output)
965014 SPC connecting cable 2m (for output)
907020 GO/NG judgment output cable
* Optional accessories for output from display counter.
I-20
I-21 (2003) full size 12/8/03 9:19 PM Page 1
Quill Kit
Easy Installation
Fits Most Vertical Knee Mills
Features
• Easy to read LCD with resolution of .0005"/0.01mm.
• Push button controls for inch/mm, Zero-Set and
On/Off.
• Powered by a single SR-44 Battery which lasts about
1 year with normal use.
• SPC Output for data transmission to Data Processors
or LED Remote Display Box.
Specifications
Quill Kit
Order No. Description
053906A Digimatic Quill Kit complete with brackets &
scale for Bridgeport Type machines.
The new Mitutoyo Quill Kit mounted on a vertical mill.
AB
Y
OG
With Incremental Encoder EC
H N OL
T
Inch/Metric
Single Function Type
Order No. Dimensions Function
Horizontal Vertical Range Resolution Accuracy L1 L2 t • Zero-setting
• Data hold
––– 572-330 4"/l00mm .0005"/0.01mm .001"/0.03mm 9.606" 8.661" .236" • Data output
––– 572-331 6"/150mm .0005"/0.01mm .001"/0.03mm 11.575" 10.630" .236" • Inch/mm Conversion
––– 572-332 8"/200mm .0005"/0.01mm .001"/0.03mm 13.543" 12.598" .236"
––– 572-333 12"/300mm .0005"/0.01mm .002"/0.04mm 17.480" 16.353" .236"
572-234 572-334 18"/450mm .0005"/0.01mm .002"/0.04mm 23.386" 22.441" .236"
572-235 572-335 24"/600mm .0005"/0.01mm .002"/0.04mm 30.472" 29.528" .236"
572-236 572-336 32"/800mm .0005"/0.01mm . 25"/0.06mm 38.346" 37.402" .394"
572-237 572-337 40"/1000mm .0005"/0.01mm .25"/0.06mm 46.220" 45.276" .394"
rear surface.
I-21
I-22 (2003) full size 12/8/03 9:19 PM Page 1
AB
functions which allow it to always remember its measuring position
Y
OG
even after the gage has been switched off. EC
H N OL
T
Single Function Type
Horizontal
Order No. Range Resolution Accuracy L1 L2 t Function
572-210-10 4"/100mm .0005"/0.01mm .001"/0.03mm 8.228" 7.283" .138" • ZERO/ABS changeover
• Origin-setting
572-211-10 6"/150mm .0005"/0.01mm .001"/0.03mm 10.197" 9.252" .138"
• Inch/mm conversion
572-212-10 8"/200mm .0005"/0.01mm .001"/0.03mm 12.244" 11.299" .138" • Data output
572-213-10 12"/300mm .0005"/0.01mm .002"/0.04mm 17.5" 16.5" .150" • Data hold (with optional Data Hold Switch)
Vertical
Order No. Range Resolution Accuracy L1 L2 t Function
572-310-10 4"/100mm .0005"/0.01mm .001"/0.03mm 9.606” 8.661” .150” • ZERO/ABS changeover
• Origin-setting
572-311-10 6"/150mm .0005"/0.01mm .001"/0.03mm 11.575” 10.630” .150"
• Inch/mm conversion
572-312-10 8"/200mm .0005"/0.01mm .001"/0.03mm 13.543” 12.598” .150" • Data hold (with optional Data Hold Switch)
572-313-10 12"/300mm .0005"/0.01mm .002"/0.04mm 17.480” 16.535” .150"
Multi-Function Type
Order No.
Horizontal Vertical Range Resolution Accuracy L1 L2 t Function
572-470 572-570 4"/100mm .0005"/0.01mm .001"/0.03mm 9.606" 8.661" .150" • ZERO/ABS changeover
• Origin-setting
572-471 572-571 6"/150mm 0005"/0.01mm 001"/0.03mm 11.575" 10.630" .150" • Inch/mm conversion
572-472 572-572 8"/200mm 0005"/0.01mm 001"/0.03mm 13.543" 12.598" .150" • Data output
572-473 572-573 12"/300mm 0005"/0.01mm 002"/0.04mm 17.480" 16.535" .150" • Data hold
• Presetting
572-474 572-574 18"/450mm 0005"/0.01mm 002"/0.04mm 23.386" 22.441" .236"
• Counting direction
572-475 572-575 24"/600mm 0005"/0.01mm 002"/0.04mm 30.472" 29.528" .236" Changeover
572-476 572-576 32"/800mm 0005"/0.01mm 0025"/0.06mm 38.346" 37.402" .394"
572-477 572-577 40"/1000mm 0005"/0.01mm 0025"/0.06mm 46.220" 45.276" .394"
I-22
I-23 (2003) full size 12/8/03 9:20 PM Page 1
rear surface
I-23
I-24 (2003) full size 12/8/03 9:20 PM Page 1
Attention:
When it is changed from the following goods, a dimension to the back of slider from scale unit installation standard side is different.
Be careful because spacer (optional accessories) of the bottom figure is necessary.
ø3.5 64
40
30
t=1.5mm
I-24
I-25 (2003) full size 12/8/03 9:21 PM Page 1
Proscale
Series 950
ProScale ABSTM with Fraction/Decimal
Reading
Mitutoyo’s new ProScale ABSTM Absolute Encoder.
Fractions to 1/64th of an inch are possible and decimals
can be displayed in inch or metric.
Features
• Resolution: .001", 0.01mm 1/64 inch
• Zero, increment or decrement reading with front panel
button.
• Display range: 0 to ±394.000"
DISPLAY IN FRACTION DISPLAY IN FRACTION
0 to ±9999.99mm MODE MODE
0 to ±99 63/64 inches
• Power: Two standard AA batteries/display indicate low
power. Battery Life one year with normal use.
Fraction Mode Decimal Mode
• Operating temperature: 32° to 120°F (1/32 inch) (.001 inch)
• Patent: U.S. Patent#’s 4420754, 4879508, 4878013,
4959615
Model 150 Decimal Mode
Fraction Mode
(1/16 inch) (0.01 mm)
Model 250
Specifications
Complete Sets (Display, Scale, Reading Head & Cable*)
Order No. Range Accuracy Description
950-404 0–10"/0–250mm ±.002"/±0.05mm Model 150-10
950-405 0–18"/0–450mm ±.003"/±0.08mm Model 150-18
950-406 0–52"/0–1,320mm ±.008"/±0.2mm Model 250-4
950-407 0–96"/0–2,400mm ±.008"/±0.2mm Model 250-8
Individual Components
Order No. Range Accuracy Description
950-005 –– –– Display Monitor for ProScale ABSTM
with SPC output
Display Monitor
950-006 –– –– Reading Head & Cable (Model 150, 250)
950-004 –– –– Stand for display monitor
950-433 0–10"/0–250mm ±.002"/±0.05mm Scale w/Reading Head & Cable*
950-436 0–18"/0–450mm ±.003"/±0.08mm Scale w/Reading Head & Cable*
950-441 0–52"/0–1320mm ±.008"/±0.2mm Scale w/Reading Head & Cable*
950-445 0–96"/0–2400mm ±.008"/±0.2mm Scale w/Reading Head & Cable*
*Cable 2m (80") supplied as standard.
For SPC output order connecting cable 936937 (1m) or 965014 (2m).
I-25
J-01 (2003) full size 12/11/03 3:50 PM Page 1
ISO 9000
Traceability Standards J-2
Dial Gage Tester - Series 170, Standard Scale - Series 182 J-10
Inside Micrometer & Bore Gage - Setting Rings - Series 177 J-11
J-02 (2003) full size 12/8/03 3:55 PM Page 1
ISO 9000
Once / 2 years
Utunomiya C.C.
Gage Block
(Daily use reference
Standard) Laser Length
JCSS No. 0078 Reference Scale
Measuring
(Working Standard)
Machine
(Working
Reference Standard)
Gage Block
(Working standard)
Calibration Equipment
(working Standard)
Measuring
Gage Block Scale Laser Source
Instruments
Iodine Absorption Stabilized He-Ne Laser as the Interferometer as the standard for Gage Block
standard for length measurement calibration (At Miyazaki Plant)
(At Tsukuba Calibration Center)
J-2
J-03 (2003) full size 12/8/03 3:56 PM Page 1
ISO 9000
Malaysia Singapore Taiwan USA Mexico Brazil UK The Netherlands Germany Switzerland Italy
SIRIM PSB NML NIST CENAM INMETRO NPL NMi PTB OFMET IMGC
EA <Mutual Recognition>
SAC-
DSM CNLA A2LA EMA RBC UKAS NKO DKD SAS SIT
SINGLAS
Mitutoyo Mitutoyo Mitutoyo Mitutoyo Mitutoyo Mitutoyo Mitutoyo Mitutoyo Mitutoyo Mitutoyo Mitutoyo Mitutoyo
(Malaysia) Asia Taiwan America Mexicana Sul (UK) Nederland Miyazaki Mess Schweiz Italiana
Sdn. Bhd. Pacific Corp. Americana Plant geräte
# SAMM # SL # 0336 (IL) # D-45 # 031 # 0332 # K 086 # K 107 # DKD-K # SCS # 107
152 96102-C # 750.01 14501 074
Mitutoyo America
Corp (MI)
1472.01
J-3
J-04 (2003) full size 12/8/03 3:56 PM Page 1
ISO 9000
Category Accreditation
Miyazaki Plant End-standard (Gage Block) 0.1mm up to NITE 0030 May 02, 1994
600mm
Domestic
Gage Block 0.1mm up to 100mm NKO K 107 Feb 20, 1997
Operations
Kiyohara Plant Line-standard (Standard Scale) up to NITE 0067 Aug 07, 1996
500mm
Tsukuba Wavelength (633nm range) of laserlight NITE 0031 May 02, 1994
Calibration Center source length measurement
Utsunomiya End-standard (Gage Block) 0.5mm up to NITE 0078 May 06, 1998
Calibration Center 250mm
Foreign Mitutoyo (UK) Ltd. Gage block and Measuring instrument UKAS 0332 July 30, 1991
Operations
Mitutoyo Sul Gage block and Measuring instrument RBC 031 Sep 15, 1992
Americana Ltda.
Mitutoyo Gage block 0.5mm up to 100mm DKD DKD-K-14501 Jan 10, 1995
Messegerate GmbH
Mitutoyo Italiana S.R.L. Gage block 0.5mm up to 100mm SIT 107 May 01, 1998
Mitutoyo Nederland B.V. Gage block and Measuring instrument NKO K 086 Oct 14, 1994
Mitutoyo Asia Pacific Gage block and Measuring instrument SAC-SINGLAS SL96102-C Nov 18, 1996
Pte. Ltd.
Mitutoyo (Malaysia) Measuring tools DSM SAMM 152 Oct 15, 1998
Sdn, Bhd.
Mitutoyo America Corp. Gage Block A2LA 750.01 Apr 20, 1998
Mitutoyo Roughness specimen, MIC reference hemi- CNLA 0336 Jun 15, 1998
Taiwan Co., Ltd. sphere, Toolmakers microscope, Profile pro-
jector
NITE: National Institute of Technology and Evaluation (Japan) DKD: Deutscher Kalibrierdienst (Germany) SCS: Swiss Calibration Service (Switzerland)
NKO: Nederlandse Kalibratie Organisatie (The Netherlands) SIT: Servizio di Taratura in Italia (Italy) A2LA: American Association for Laboratory Accreditation (USA)
UKAS: United Kingdom Accreditation Service (UK) SNC: Sistema Nacional de Caliracion (Mexico) CNLA: Chinese National Laboratory Accreditation (Taiwan)
RBC: Rede Brasileira de Calibracao (Brazil) PSB: Singapore Productivity and Standards Board (Singapore)
J-4
J-05 (2003) full size 12/8/03 3:57 PM Page 1
ISO 9000
Reference Gage
Rectangular Gage Block Sets Square Gage Block Sets
Series 516 Series 516
Features Features
• Mitutoyo offers a selection of rectangular gage blocks available • Mitutoyo offers a selection of square gage blocks available
in choice of metric or inch, steel or ceramic (CERA) types and in choice of metric or inch, steel or ceramic (CERA) types
ISO/JIS/DIN or Federal Specification or British Standard. and ISO/JIS/DIN or Federal Specification.
• All types are prepared by highly advanced techniques in the most • All types are prepared by highly advanced techniques in the
modern facilities to produce the fine characteristics required of most modern facilities to produce the fine characteristics
gage blocks. required of gage blocks.
• Provided with inspection certificate. • Provided with inspection certificate.
• Mitutoyo CERA Blocks are some of the finest gage blocks available
(Reference Catalog Section T for more details)
anywhere in the world. CERA Blocks are made of zirconia ceramic.
• Steel gage blocks are made of a special steel alloy.
(Reference Catalog Section T for more details)
Black Granite Surface Plates
Gage Blocks Series 517
Features Features
• Mitutoyo offers individual Gage Blocks as follows. • Provided with a reference surface for precision height and
Rectangular Gage Blocks (.004"-20"/0.1-1000mm) squareness measurements and layout.
CERA Rectangular Gage Blocks (.03125"-20"/0.5-500mm) • Sizes are available from 8" x 12" and up to 72" x 144".
Square Gage Blocks (.01"-20"/0.5-500mm) • Various granite accessories are also available.
CERA Square Gage Blocks (.05"-4") (Reference Catalog Section U for more details)
(Reference Catalog Section T for more details)
J-5
J-06 (2003) full size 12/8/03 3:57 PM Page 1
ISO 9000
Gage Block
s
ngth
Gage Block Calibration Equipment Wav
ele
Two
Automatic Gage Block
Interferometer GBI
Target preliminary measurement
range expanded sevenfold with
two wavelengths
The Two-Wavelength Automatic Gage Block Interferometer, GBI
is an easy to use gage block
interferometer capable of absolute measurement of central
length of gage blocks with the utmost accuracy.
• Two Ne-He laser light sources are adapted to ensure
extremely reliable measurements. Preliminary
measurement with up to 1µm uncertainty is satisfactory for
interferometry with the GBI.
• No human intervention in observing the interference fringes.
This eliminates human errors in measurements.
• Remote control of the system is possible in measurement.
This facilitates preventing the operator heat from affecting the
gage blocks inside the interferometer. Specifications
• Air refractive index correction and gage block thermal expan- Light source He-Ne laser (633nm and 543nm)
sion correction are automatically performed with the computer Measuring range Up to 250mm
connected to the thermometer, hydrometer and barometer. Uncertainty of measurement: 0.025µm+0.2x10-6L
• An array of 12 gage blocks set up within the interferometer (Coverage factor k=2) L=nominal length (µm)
can be continuously measured within 5 minutes for each
Number of blocks installable 12 pcs.
block.
Dual head
Differential Type Automatic
Gage Block Comparator
GBCD-100A
Differential
measurement
ISO recommended differential type
with dual gage head for automatic
high accuracy measurement
Specifications
Code No. 565-111A
Applications Rectangular gage blocks and square gage
blocks
Measuring range 0.5mm to 100mm
Display resolution 0.01µm
Measurement method Differential measurement with dual head
Upper gaging head Electric micrometer of 1N measurement force Dual head type of gage block comparator capacity of auto-
Carbide contact point of radius of 20mm matic calibration of gage block lengths between 0.5mm and
Lower gaging head Electric micrometer of 0.6N measurement force 100mm with reference to the reference gage block.
Carbide contact point of radius of 5mm • Dual head feature eliminates the error due to the warp of
thin gage block.
Accuracy (20°C)* ±(0.03+0.3L/1000µm, L=nominal length (mm)
• Automatically measures the center and four corners of a
Air requirement 400KPa gage block with reference to the center length of the refer-
Temperature 20°C±1°C ence gage block.
Dimensions (WxDxH) Measuring unit 710 x 366 x 783mm • Calibration results are automatically processed with the
Electric unit 160 x 410 x 382mm GBPAK Calibration Program.
*95% confidence coefficient. Excluding uncertainty of reference gage block length • Measurements for evaluation with ISO, JIS, DIN, ANSI, etc.
J-6
J-07 (2003) full size 12/8/03 3:58 PM Page 1
ISO 9000
Gage Block
Gage Block Calibration Equipment
Specifications
Code No. 565-131A
Applications Rectangular gage blocks and square gage blocks
Measuring range 0.1mm to 250mm
Resolution 0.01µm
Measurement method Differential measurement with dual head
Upper gaging head Laser Hologage (0.1µm, ±3mm) of 0.8N measuring force. Carbide contact point of radius of 20mm
Lower gaging head Electric micrometer of 0.6N measuring force
Carbide contact point of radius of 5mm
Accuracy (20°C)* ±(0.03+0.3L/1000µm, L=nominal length (mm) (the nominal length must be the same for both the reference gage block and
the one to be calibrated)
±(0.06+0.3L/1000)µm, L=nominal length (mm) (for grades 1 and 2: with the reference gage block of length difference with-
in ±3mm)
Temperature 20°C±1°C
Dimensions (WxDxH) Measuring unit 455 x 318 x 691mm
Electric unit 345 x 397 x 187mm
(Excluding connectors)
*95% confidence coefficient.
Excluding uncertainty of reference gage block length.
GBPAK Calibration Program and personal computer are optional.
J-7
J-08 (2003) full size 12/8/03 3:58 PM Page 1
ISO 9000
Gage Block
Gage Block Calibration Equipment
Manual
Gage Block Comparator
GBCS-250 Single head
Specifications
Code No. 565-120A
Applications Rectangular gage blocks and square gage blocks
Measuring range 0.1mm to 250mm
Resolution 0.01µm
Measurement method Single head
Gage head Laser Hologage (0.1µm, ±5mm) of 0.8N measuring force Carbide contact point of radius of 20mm. Anvil has a curvature.
Accuracy (20°C)* ±(0.03+0.3L/1000µm, L=nominal length (mm) (the nominal length must be the same for both the reference gage block and
the one to be calibrated)
±(0.06+0.3L/1000)µm, L=nominal length (mm) (for grades 1 and 2: with the reference gage block of length difference with-
in ±3mm)
±(0.1+0.3L/1000)µm, L=nominal length (mm) (for grade 2: with the reference gage block of length difference
within ±5mm)
Temperature 20°C±1°C
Dimensions (WxDxH) Measuring unit 300 x 300 x 686.5mm
Electric unit 235 x 1151 x 118mm
(Excluding connectors)
*95% confidence coefficient.
Excluding uncertainty of reference gage block length.
GBPAK Calibration Program and personal computer are optional.
J-8
J-09 (2003) full size 12/8/03 3:59 PM Page 1
ISO 9000
Ring Gage
Ring Gage Calibration Equipment
Ring Gage Measuring Machine
Ring Master
RM-120
Incorporated 120mm Laser Holoscale
eliminates the need for multiple
reference gages, permitting expertise-
free high accuracy direct ring gage Standard
measurements with reduced total cost. counter type
Incorporated with a high precision laser holoscale with a
resolution of 0.01µm, the Ring Master RM-120 directly
measures the ring gage diameter between 6mm and 120mm
without referring to otherwise required reference ring gages,
efficiently and accurately. The measurement efficiency can be
increased 100% over the conventional method where wringing
gage blocks is required.
• The laser holoscale eliminates the need for a reference gage
block set and reference ring gages.
• The line of measurement of the ring gage is on the axis of
standard, meeting the Abbeis principle and ensuring higher
measuring accuracy.
• Stylus change is not required for the entire measuring ring.
• Enhanced repeatability and lower measuring force achieved
with the air bearing on the stylus carriage guide.
• Workpiece alignment is easy to perform with specially
designed table which is capable of translation, tilting, eleva-
tion, and 90° rotation. The model with analog meter will
further facilitate workpiece translation and tilting.
J-9
J-10 (2003) full size 12/8/03 3:54 PM Page 1
ISO 9000
Features Features
• The Caliper Checker is designed to calibrate vernier, dial and • A stack of 10mm (.5”) gage blocks is fixed in a rigid cast
digimatic calipers of various types. It is composed of permanently iron frame to form a reference gage, providing a means of
wrung, high-grade gage blocks in a protective casting. calibrating coordinate measuring machines and inspecting
(Reference catalog section V for more details) the feed accuracy of machine tool tables.
(Reference catalog section V for more details)
Dial Indicator
Dial Gage Tester Length Standard
Series 170 Standard Scale
Series 182
Features
Features Code No. 182-501 182-502
• Used for checking the accuracy of dial indicators, dial test indicators Measurement Length (mm) 250 500
and Mu-Checker gage heads. Overall Length (mm) 280 530
(Reference catalog section R for more details) Width of Scale (mm) 20
Thickness of Scale (mm) 10
Working Standard Scale Material Optical Glass
Linear Expansion/K 8 x 10-8
Series 182 Line Thickness 4
Scale Pitch (µm) 1
Accuracy (µm) (at 20°C) 0.5+L/1000
L: Between arbitrary 2 line
Code No. 182-511 182-512 182-513 182-514 182-521 182-522 182-523 182-524 182-525 182-531 182-532 182-533 182-534
Measurement Length (mm) 50 100 150 200 100 200 300 400 500 250 500 750 1000
Overall Length (mm) 75 125 175 225 130 230 330 430 530 280 530 780 1030
Width of Scale (mm) 22 22 22 22 36 36 36 36 36 36 36 36 36
Thickness of Scale (mm) 2.7 2.7 2.7 2.7 4.7 4.7 4.7 4.7 4.7 4.7 4.7 4.7 4.7
Material Soda-lime glass
Linear Expansion/K 8 x 10-6
Line Thickness 20 50 100
Scale Pitch (µm) 0.1 0.5 1
Accuracy (µm) (at 20°C) 1.5+2L/1000
L: Between arbitrary 2 line
J-10
J-11 (2003) full size 12/8/03 3:54 PM Page 1
ISO 9000
Outside Micrometer
Rectangular Gage Block Sets for Micrometer Standards
Outside Micrometer Inspection Series 167
Series 516
Features
• Used for zero point adjustment of outside micrometers
• Sizes available from 25mm up to 100mm.
• Standards from screw thread micrometers and V-anvils
Features micrometers are also available.
• Gage block sets specially assorted for inspection of instrumental (Reference Catalog Section L for more details)
error of outside micrometer, flatness and parallelism of measuring
faces.
• Mitutoyo offers a selection of gage block sets available in choice
of metric or inch, steel or ceramic (CERA) types.
(Reference Catalog Section T for more details)
Depth Micrometer
Depth Micro Checker
Inside Micrometer Series 515
Inside Micro Checker
Series 515
Features
• The inside Micro Checker is designed to efficiently check the zero
point of a tubular inside micrometer. Features
• Each measuring block is made of zirconia-based ceramic and is • The Depth Micro Checker is designed to efficiently check
free from deterioration and dimensional changes over time. the zero point of a depth micrometer.
(Reference Catalog Section V for more details) (Reference Catalog Section V for more details)
J-11
K-01 (2003) full size 12/11/03 3:49 PM Page 1
Data Management
(SPC)
DATA MANAGEMENT
SPC Networkability
MEASURING SOLUTIONS with MeasurLink®
Most of Mitutoyo’s electronic instruments can output Inspection in the factory turns into analysis data, man-
data via optional connecting cables or wireless agement reports, and corrective action. As the back-
transmitters & receivers in the form of the Digimatic bone of your quality efforts, MeasurLink® is guaranteed
code. This signal is designed to go directly into Mitutoyo to reduce your production costs and increase your
data processors such as the DP-1VR. The Digimatic bottom line.
code can also be converted into RS-232C format by any
of several available interface units. In this way, digital Scalable Network
data can be sent to PCs for data acquisition and MeasurLink® is capable of linking and managing multi-
advanced SPC analysis. ple “islands” of inspection. A common database of
SPC, gage, operator, parts, processes, etc. Information
MeasurLink® is scalable to meet the demands of any
quality programs. You can increase the number of is shared across an entire manufacturing facility.
real-time data collection workstations seamlessly. As a Relational Database
client/server application, MeasurLink® gives you the MeasurLink® is an ODBC compliant application qualified
performance you need through distributed processing. for use with the following database management systems:
Combined with a multi-user relational database,
• Microsoft® SQL Server
MeasurLink® delivers a safe and organized data
warehousing system. • Sybase® SQL Anywhere
Each MeasurLink® SPC Real-Time workstation can be • Oracle®
linked to a central database, where it is available for • Sybase® Adaptive Server
viewing and analysis by any member of the production,
engineering and managerial staff throughout your company.
MeasurLink®
SPC Solution System
Gage R&R Gage Management SPC Process Analyzer SPC Process Manager
Multiplexer Multiplexer
K-2
K-03 (2003) full size 12/10/03 10:49 AM Page 1
DATA MANAGEMENT
MeasurLink ®
Easy-to-use SPC
MeasurLink® gives you the most intuitive interface with
complete SPC functionality to help you monitor and
manage your manufacturing processes. With MeasurLink®,
you can easily manage the quality levels of your parts,
identify problem areas and apply corrective action to
areas in need of attention.
K-3
K-04 (2003) full size 12/10/03 10:50 AM Page 1
DATA MANAGEMENT
MeasurLink ®
Real-Time Data
MeasurLink® performs as a data acquisition clearinghouse
by enabling you to connect and acquire data from virtually
any measuring device. It supports the full range of metrology
technology, including calipers, micrometers, indicators,
CMMs, vision systems and more.
K-4
K-05 (2003) full size 12/10/03 10:50 AM Page 1
DATA MANAGEMENT
MeasurLink ®
K-5
K-06 (2003) full size 12/10/03 10:50 AM Page 1
DATA MANAGEMENT
MeasurLink ®
K-6
K-07 (2003) full size 12/10/03 10:51 AM Page 1
DATA MANAGEMENT
MeasurLink ®
Gage R&R
Gage Repeatability and Reproduceability is a study
method used to validate the accuracy of your SPC
inspection data.
MeasurLink® Gage R&R 6.0 : 64AAS941B
MeasurLink® Gage R&R is a Microsoft® Windows®-based
Gage R&R software designed to the AIAG (Automotive
Industry Action Group) Measurement System Analysis
standard for QS9000.
MeasurLink® Gage R&R integrates with MeasurLink®
SPC Real-Time and provides the same ease of use
with hands free data entry. In fact, Gage R&R works
with virtually any gages. In addition to the standard calculations this software also
• Supports the following AIAG study methods. provides graphical tools for analysis of the measurement
system. The Xbar and R chart can show whether there
1) Range method. is adequate gage discrimination to record part to part
variation in production and if operators are self-consistent.
2) Average and range method.
The Part-by-Appraiser plot can show if there is a lack of
3) Average and range method including within part consistency between operator inspection techniques.
variation.
4) Analysis of variance method.
5) Short method for attribute gages.
6) Bias study.
7) Linearity study.
8) Stability study.
• Input methods include: keyboard entry, direct gage
input, DDE and text import.
• Builds a gage inventory and records your R&R study
efforts.
• Generates reports that your customers will respect and admire.
• Provides graphical interpretation of appraiser consistency.
This software supports up to 15 appraisers per study,
15 trials per appraiser and 15 parts per trial. Each study
supports a Gage ID, Gage type, Serial Number, Note,
etc. A full search engine is available. This product is
also integrated with MeasurLink Gage Management for
recall and reporting purposes.
K-7
K-08 (2003) full size 12/10/03 10:51 AM Page 1
DATA MANAGEMENT
MeasurLink ®
K-8
K-09 (2003) full size 12/8/03 9:32 PM Page 1
DATA MANAGEMENT
Pocket ML
New mobile solution to MeasurLink® Family
Color Display: 982-555
Black & White Display: 982-554
Features Specifications
• Pocket ML is the mobile data collector, the industry's first all-new Order No. Description
portable data collection device powered by Microsoft Windows for 982-555 Color Display USB Cable
Pocket PC platform. 982-554 Black & White display USB Cable
• MeasurLink® Pocket ML is full function SPC data collection software
designed for portable data collection and event logging.
• Pocket ML collects measurements from a single gage and supports
timed input. Inspection data can be imported into MeasurLink® SPC TRADEMARKS
Real-Time, MeasurLink® SPC Real-Time PLUS, MeasurLink® Process Compaq and the names of Compaq products referenced herein
Analyzer or a text file formatted as a simple report in Microsoft Excel are trademarks and/or service marks or registered trademarks
or Word, via standard USB cable. and/or service marks of Compaq. Microsoft Windows is a
registered trademark of Microsoft Corporation. Intel is a
• Connect to the Pocket ML using Standard Mitutoyo SPC Cable. registered trademark of the Intel Corporation.
K-9
K-10 (2003) full size 12/15/03 10:34 AM Page 1
DATA MANAGEMENT
Features Specifications
Mitutoyo's new DP-1VR is so compact, it fits right in your palm. But with Order No. 264-504A
this powerful little device you can print data from your Digimatic caliper, Printing method Thermal line printer
micrometer and more using the Data Output function, and can even Printing dot 384dot (8dot/mm)
calculate statistics, Printing speed is excellent, and with the built-in ther- Printing speed 6.5mm/s (using AC adapter)
mal line printer there's virtually no noise. What's more, the Printing paper 48mm
thermosensitive paper has outstanding durability and chemical
Printing line Approx. 6500 lines of large characters
resistance for long-term storage. The DP-1VR even lets you transmit
the data to a computer using an RS232C connecting cable Approx. 12000 lines for normal characters
(09EAA084). Processing capacity mode 1/2/3: 9999 data
mode 0: 100000 data
Printing data Measurement data, GO/±NG judgement,
Standard Accessories number of data, maximum/minimum value,
User's manual, Printer paper: 10 rolls (09EAA082), AC adapter
range, average, standard deviation, number
(09EAA088 (100V/120V), Key operation quick reference, Wrist strap
of defective, fraction defective, process
capacity index, histogram, D-chart, control
Optional Accessories chart generation for Xd-bar and control
09EAA084* RS232C changing cable (1m, 9pin) limit data, date and time
965516* GO/±NG judgement cable Output function Output the measuring data (RS232C) or
937179T Foot switch GO/±NG judgement
*It is impossible to use both RS-232C cable and GO/±NG) judgement Input timer 0.25s, 1s, 5s, 30s, 1min, 30min, 60min
cable at the same time. Power AC adapter 6V (Not interchangeable to
DP-1HS) Electric battery: LR6 (alkaline). Ni-
Alarm functions Mh (AA size)
• Line voltage Voltage abnormality Battery life 10 years (clock battery), 100000 lines
• Paper end No printer paper (1600mA 1 times/5sec. using the nickel
• Head up Paper cover open hydrofluoric battery)
Operating 0°C to 45°C (using AC adapter),
• Head Thermal abnormality of printer head
temperature temperature 10°C to 45°C (using battery)
Storage -10°C to 50°C
• Over flow Data input limit
temperature
• Battery Voltage drop of battery for clock
• Input data Communication abnormality with measuring devices
K-10
K-11 (2003) full size 12/9/03 11:41 AM Page 1
DATA MANAGEMENT
Input Tool
Series 264
Features
• Any one Mitutoyo SPC output device can be sent directly to MS Excel
(264-005, 264-012) or converted to RS-232C (264-007).
• Power is supplied from the PC automatically.
• Data can be sent by Data Button on Input Tool or instrument or by
optional footswitch (937179T).
Note:
• USB Connector (type A)
• Compatible with Windows® 98 and above (not including Windows® NT)
Sample screen (MS-Excel 97 with #264-005 or 264-012) Sample screen Measurlink® R/T Plus #64AAS802B with #264-007
Input Tool for keyboard 264-005 Input Tool for RS-232C 264-007
• Allows measurement data to be directly input to a commercial • Allows measurement data from a Mitutoyo Digimatic tool to be input
spreadsheet such as Microsoft Excel, Lotus 1-2-3, etc. to a SPC software (such as MeasurLink®, etc.) via RS-232C port.
• No special software for PC input is necessary. The user can use his (Please refer to the operation manual for connection.)
own software for data collection.
Note:
(Please refer to the operation manual for connections. Laptop
computer connection is slightly different from desk-top • D-sub 9-pin (female) connector is used. A connector for
computer connection.) conversion is required for D-sub 25-pin type connector.
Note:
• Mini DIN 6-pin connector for PS/2 is used. Adapter for conversion is Optional Accessory: 937179T Foot Switch
required for AT style keyboards.
• Cannot be connected to a computer with keyboard for USB (use
264-012).
• Runs on Windows® 95/98, MS-Windows® 3.1, and MS-DOS (PC-DOS).
• PS/2 keyboard plugs into 264-005, thus, the keyboard and 264-005 can be
used simultaneously.
Specifications
Product Input Tool for Keyboard Input Tool for RS-232C Input Tool for USB
Code No. 264-005 264-007 264-012
Measuring Tools Required*1 Mitutoyo Digimatic measuring tools with SPC output
PC Requirement PC compatible, PC Compatible, PC Compatible,
with PS/2 style keyboard interface*2 (including laptops) with RS-232C Interface (including laptops) with
(Can be also connected to a laptop computer.) Connects to RS-232C port on CPU USB 2.0 or 1.1 port
Connects to keyboard port on CPU (D-sub 9-pin connector)
Outside Dimensions HxWxD 2.8" x 1.7" x .9"
(72 x 44 x 23.5 mm)
Mass 2.5oz. (70g)(including cable and connector) 3.2oz. (91g)(including cable and connector) 2.6oz. (74g)
*1: Connecting cable (optional accessory) is required for a connection to a Digimatic measuring tool.
*2: Cannot be used for computers that use USB keyboard. When using a IBM Think Pad Series, a commercial keyboard adapter is required.
When using AT style keyboard, adapter for conversion is required.
K-11
K-12 (2003) full size 12/8/03 9:35 PM Page 1
DATA MANAGEMENT
Digi-Card 015873
MUX-200
982-532A
MIG-4 982-548
MUX-110
982-534A
MIG-2A 982-547
Add-On Unit
50AAA005
K-12
K-13 (2003) full size 12/8/03 9:35 PM Page 1
DATA MANAGEMENT
Specifications
Input tool Input tool
Functions Digi-Card UP-1 MIG-2A MIG-4 MUX-110 MUX-200
for keyboard for RS232C
Gage Capacity 3 1 8 4 2(6 Max.) 2(8 Max.) 1 1
Accepts analog input — — — — — • — —
Accepts RS-232C input — • — — — • — —
Outputs RS-232C to computer — • • • • • (Keyboard) •
Measurement buffer — — • • • • — —
Software can poll gages
for their readings • • • • • • — •
Accepts random gage input • — • • • • — —
Foot switch support 937179T — — • • — • — —
Expandable • — — — • • — —
Will output all gages
connected with one command — • • • • • — —
No cable between gage
and multiplexer — — — — — — — —
Variable transmission rate — • • • • • — —
Reset • • • • • • — —
• States multiplexer is capable of function — States multiplexer is not capable of function
K-13
K-14 (2003) full size 12/8/03 9:36 PM Page 1
DATA MANAGEMENT
Wireless Measure®
Mitutoyo's Exclusive Wireless SPC
Data Acquisition System Signals New
Flexibility in Quality Control
It’s called Wireless Measure®, and it incorporates the
use of a few simple tools to expand your measuring
envelope, eliminate restrictive cables, and step light
years ahead of conventional SPC data acquisition.
A Mitutoyo caliper, micrometer, and retrofit add-on unit
have been specially constructed to include push-button
transmitters, capable of sending signals up to 80 feet.
Receiver 02AZC480
K-14
K-15 (2003) full size 12/8/03 9:36 PM Page 1
DATA MANAGEMENT
ALL MICROMETERS
Indicators 543-11X, 543-13X, 543-14X, 543-18X, 543-17X
Holtest 468-2XX, 468-9XX
937387 965013 64AAA026 64AAA027 Micrometer Head 164-162, 164-172, 350-71X, 329-71X
Borematics 568-XXX
(6 pins) Others Mikematic, Quickmike
Bench Mike 121-XXX
K-15
K-16 (2003) full size 12/8/03 9:37 PM Page 1
DATA MANAGEMENT
Remote Display
Counters
Large, Bright LED for Digimatic Gage
with Output*
Specifications
Remote Display Counters
Inch
Order No. 572-011A 572-031A
Resolution* .0005"/0.01mm or .001"/0.01mm
.00005"/0.001mm .0005"/0.01mm or
.0001"/0.001mm or
.00005"/0.001mm
Type Single-function Multi-function
Display Green LED, 6-digit, +/– decimal point
Functions • Zero-setting • Zero-setting
• Data output • Data output
• Miscount alarm • Miscount alarm
• Presetting
• GO/±NG judgment
• Direction changeover
Dimensions
7.9" x 4.7" x 2.6" 9.3" x 4.8" x 2.6"
(W x D x H)
Weight 2.4 lbs. (1.1 kg) 2.9 lbs. (1.3 kg)
Power supply AC adapter (9VDC) 526688A
*Note: The 572-011A counter can only be used with Digimatic Gages which have
.0005"/0.01mm or .00005"/0.001mm readout.
K-16
K-17 (2003) full size 12/8/03 9:38 PM Page 1
DATA MANAGEMENT
Digimatic Multi-Unit
Series 572
6-Channel Multi-Point Measuring Unit
Features
• The Multi-Unit receives data from up to six Digimatic gages. 572-052A
• By connecting a multi-function type Display Unit (572-031A)
to the Multi-Unit, measurement from each gage can be dis-
played, and max, min, and range measurements can be
made for the connected gages. Also possible are GO/NG
judgments on the measurement data individually or
collectively.
• Tolerance judgment and zero-setting can be triggered using
a foot switch (937179T).
• The back up memory stores the tolerances entered, after the Rear Panel
power to the Multi-Unit is turned off.
• Optional accessories: 937179T Foot switch
907020 GO/±NG judgment Examples of Connections
cable (2m)
936937 Digimatic cable (1m)
965014 Digimatic cable (2m)
Specifications
Digimatic Multi-Unit Multi-Unit
Order No. 572-052A
Remote Display
Functions • MAX/MIN measurement
572-031 (SD-D2)
• Range measurement Digimatic Gages
• Zero-setting DP Series
• Tolerance setting Miniprocessor
• Presetting
• GO/±NG judgment (Buzzer and LED) Foot switch*
(optional)
• Error alarm
937179T
Power supply AC adapter (9VDC) 526688A
Dimensions (W x D x H) 9.3" x 4.8" x 2.6"
Weight 2.9 lbs. (1.3 kg)
Difference/Sum Unit
Series 572
The Digimatic Difference/Sum Unit will add or subtract the mea-
surements from two Digimatic Gages and output results to a
Remote Display Counter or SPC System. Zero-setting can be 572-041A
done at the Difference/Sum Unit (or by external switch) and direct
measurements from a single connected gage can also be
passed on without alterations.
Measuring tools
Standard accessory: 936937 Digimatic cable (1m)
526688A AC Adapter Typical setup with
output to one of
Optional accessories: 937179T Foot switch Digimatic Difference/Sum Unit
Mitutoyo’s
965014 Digimatic cable (2m) Connecting cable INPUT Connecting cable
(optional)* A B (optional)* Remote Display
Specifications EXT ZERO ADAPTER
OUTPUT
Counters. Output
Digimatic Difference/Sum Unit can also be sent
Foot switch 937179T
(optional) AC adapter to a Mitutoyo
Inch Connecting cable (supplied) Data Processor
(supplied)
Order No. 572-041A directly or indi-
Calculation mode A+B, A-B, A, B rectly through the
Function Zero-setting
Remote Display Remote Display
Power supply AC adapter (9VDC) 526688A SD-D2 572-031 Counter.
Dimensions (W x D x H) 3.0" x 4.8" x 2.6"
Weight 1.3 lbs. (0.55 kg)
K-17
K-18 (2003) full size 12/8/03 9:38 PM Page 1
DATA MANAGEMENT
Digimatic
Extension Unit
Series 572
Features
• Up to four Multi-Units (shown on previous page) can
be connected through the Extension Unit to configure
a GO/NG judgment system for up to 24 Digimatic gages.
• Max, min, and range measurements can be made for 572-061A
the connected gages.
• Tolerance judgement can be triggered using a foot
switch (937179T).
• Optional accessories
937179T Foot switch
907020 GO/±NG judgment cable (2m)
936937 Digimatic cable (1m)
965014 Digimatic cable (2m)
Specifications
Digimatic Extension Unit Rear Panel
Inch
Order No. 572-061A
Number of input channels 4 channels
Functions • MAX/MIN measurement
• Range measurement
• GO/±NG judgment (Buzzer and LED)
• Error alarm
Power Supply AC adapter (9VDC) 526688A
Dimensions (W x D x H) 9.3" x 4.8" x 2.6"
Weight 2.9 lbs. (1.3kg)
DIGIMATIC
GAGES
Digimatic cable
differs depending DIGIMATIC
on the gage to be DIFFERENCE/SUM
connected. UNIT
Up to six gages
can be connected.
DIGIMATIC
MULTI-UNITS 572-041A
DIGIMATIC
936937(1M) REMOTE
965014(2M) DISPLAY
COUNTER
572-011A
936937(1M) 937179
965014(2M)
572-061A
907020
907020 937179T
DIGIMATIC
EXTENSION UNIT
936937(1M)
965014(2M)
572-031A
K-18
K-19 (2003) full size 12/8/03 9:39 PM Page 1
DATA MANAGEMENT
VoicemanTM
Code No. 64AAC001
Innovative, Portable Voice Output
Device:
64AAC001
Calls out your readings!
Allows Workers to Hear Measurements and Tolerance
Decisions.
An Aid for the Sighted and the Sight Impaired.
Excellent for those who work in dim lighting or tight
spaces.
Speeds quality assurance and accuracy checking.
Features
• Setting of tolerance, upper and lower bound (user Language: English (default) and Spanish.
select)
Tolerance Readings:
• Vocalization of all measurement readings Upper/Lower Limit Percentage of Nominal Value Max (25%)
• Vocalization of tolerance measurement
• Supports Mitutoyo's SPC output line of products Product Specifications
• Serial output to other Mitutoyo devices Dimension: 5.75"x3.87"x1.29"
Power: AC Adapter (12VDC) or 9V Battery
(i.e., DP series printers)
Audio: 2.5 Watts Max.
• Support for a plug-in foot switch
Speaker: 8 Ohms
• Data req. function
Weight: 227g (8 0z.)
• 9 volt battery or AC adapter Battery life: 9 hours
• Speaker, ear phone port, volume control, etc.
Standard Accessories
AC Adapter (Part No. 64AAC002)
Earphone (Part No. 64AAC003)
(Not available in Canada.) Optional Accessories
Foot pedal (Part No. 937179T)
K-19
L-01 (2003) full size 12/11/03 3:49 PM Page 1
Micrometers
Accuracy Specifications L-2 Screw Thread Micrometers -
Series 326, 226, 126 L-31, 32
How to Read Inch Micrometers L-3
Pana-Mike - Series 116 L-33
Quickmike w/Absolute Encoder -
Series 293 L-4 Digimatic Bench Micrometer - Series 121 -
with Interchangeable Anvil L-34
Digimatic Micrometer - Series 293 - with or
without SPC output L-5 Caliper Type Micrometers -
Series 143, 343 L-35
Coolant Proof Micrometer IP65 Dust/Water
Protection Level L-6 Tubing Micrometers - Series 395,
295, 115 L-36
Digimatic Micrometer - Rotating
Spindle L-7, 8 Blade Micrometers - Series 422, 122 -
Non-Rotating Spindle L-37~39
Digimatic Micrometer MDC-Lite -
Series 293 L-9 Uni-Mike - Series 317, 117 - Interchangeable
Anvil Type L-40
"Micron" Outside Micrometers - Series 406,
106 - Non-Rotating Spindle For Flush Point Micrometers - Series 342,
Reading L-10, 11 142, 112 L-41, 42
Spline Micrometers - Series 331,
Outside Micrometers - Series 101 L-12
131, 111 L-43, 44
Outside Micrometers - Series 102 L-13
Disc Micrometers - Series 323, 223,
Outside Micrometers - Series 103 L-14~17 123 - Rotating Spindle Type L-45, 46
Wide Range Outside Micrometers - Series 104, Disc Micrometers - Series 369, 169 -
340 - with Interchangeable Anvils L-18, 19 Non-Rotating Spindle Type L-47, 48
Spherical Face Micrometers - Series 395, V-Anvil Micrometers - Series 314, 114 -
295, 115 L-20, 21 3 Flutes and 5 Flutes L-49
Digital Outside Micrometers - Series 193 - Crimp Height Type Micrometers -
Mechanical Dig. Counter Readout L-22, 23 Series 342 L-50
"Combimike" Digital Outside Micrometer - Hub Micrometers - Series 147 L-51
Series 159 L-24 Can Seam & Wire Micrometers -
Low Pressure Micrometers - Series 227 L-25 Series 147 L-52
Adjustable Measuring Force Digimatic Deep Throat Micrometers - Series 389,
Micrometer - Series 227 L-26 189,118 L-53, 54
Indicating Micrometer - Series 510 L-27 Micrometer Standards - Series 167 L-55, 56
Dial Snap Meters - Series 523 - High Accuracy Anvil Attachments - For Outside
Go/No-Go Gage L-28 Micrometers L-57
Gear Tooth Micrometers - Series 324, 124 Micrometer Stand - Series 156 L-58
Interch. Ball Anvil Type L-29 Groove Micrometers - Series 146 L-59
3-Wire Thread Measuring System L-30 Tool Kits - Series 950 L-60~64
L-02 (2003) full size 12/9/03 9:47 PM Page 1
MICROMETERS
Accuracy Specifications
The accuracy of a micrometer is derived from several The following comparisons clearly indicate that
fundamental factors. The most significant factors are: MITUTOYO Micrometers not only meet, but most
1) thread accuracy, 2) flatness of measuring faces, often exceed those accuracies stipulated in Federal
3) parallelism between the faces and 4) rigidity of the Specifications.
frame which holds anvil and spindle.
1)
3)
2)
Regular Thimble
4)
L-2
L-03 (2003) full size 12/9/03 9:47 PM Page 1
MICROMETERS
TO 8 TO 8
THOUSANDTHS 4
TEN-
OF AN 7 THOUSANDTHS 3 7
INCH THIMBLE OF AN INCH
6 2 6
5 1 5
SLEEVE 0
4 4
3 3
0 1 2 2
0 1 2 2
1 1
0 0
Sleeve: The Micrometer sleeve is divided into forty To read to one ten-thousandth requires an additional
equal parts. Each part or division is indicated by a verti- scale called the "Vernier" scale, named after the inven-
cal line. Each vertical line represents one-fortieth of an tor, Pierre Vernier.
inch or .025", and, each fourth line is marked by a In the case of a regular micrometer, the vernier consists
longer line and a number which designates one hun- of ten divisions, marked on the sleeve, which are
dred-thousandths. spaced within nine divisions of the thimble scale.
More simply, the line marked "1" represents .100", the Each division on the vernier, therefore, is one-tenth
line marked "2" represents .200" and so forth. shorter than that of the thimble's, thus representing
Thimble: The thimble is divided into twenty-five equal .0001".
parts, and, one complete rotation of the thimble coin- Reading Example:
cides with the smallest division on the sleeve. Thus, the
1 Read to the thousandth of an inch in the same man-
division on the thimble is one-twenty-fifth of .025"
ner as shown on the left.
or .001".
Reading Example: 2 The vernier on the sleeve reads to one-tenth of a
thousandth of an inch, or .0001".
1. Note that the thimble has stopped at a point beyond
"2" on the sleeve indicating .200" (see illustration 3 To read the vernier, find which line on the vernier
above.) scale coincides with a line on the thimble and read the
number off the vernier scale. It is important to note
2. Note that one additional line is visible between the that when finding the vernier (ten-thousandth) reading,
graduation numbered "2" and the edge of the thimble, the correct figure is ALWAYS taken from the number
indicating .025". at the vernier scale and NEVER from the thimble.
3. The line numbered "1" on the thimble coincides with 4 Note that the vernier line numbered "2" coincides
the center line of the sleeve. It means an additional exactly with a thimble line indicating .0002".
one-thousandth of an inch.
(1) Reading on the sleeve ................................. .200"
(1) Reading on the Sleeve ................................ .200"
(2) No. of lines between "2" and
(2) No. of lines between "2" and the edge of the thimble ................................ .025"
the edge of the thimble................................ .025"
(3) Thimble has passed .001" line
(3) Thimble line corresponding on the Sleeve ............................................... .001"
to the center line of the sleeve .................... .001"
(4) Vernier line coincides exactly
TOTAL READING ........................................ .226" with a Thimble Line. ..................................... .0002"
TOTAL READING ......................................... .2262"
L-3
L-04 (2003) full size 12/9/03 9:48 PM Page 1
MICROMETERS
LUT
SO E 293-676
AB
Y
OG
EC
H N OL
T
DIMENSIONS
1.26"(32) 2.74"(69.6) 1.98"(50.4)
(ø6.35)
Order No. A ø.25"
(ø24.9)
ø.98"
293-676 .98"(25mm)
293-677 1.42"(36mm)
293-678 1.85"(47mm)
A
293-679 2.36"(60mm)
ORIGIN in/mm HOLD/DATA
54 0-30mm 0-001mm
ON/OFF
Features
• Quick non-rotating 1.2" (30mm) stroke spindle... the • IP-54 protection resist water splash & shop floor
spindle advances .4" (10mm) per thimble rotation– contaminants for safe operation in harsh machine shop
no-torsion on the workpiece, reducing inspection time. environments (when not connected with data output
• Absolute Encoder... set the origin only once! The cable).
absolute linear scale tracks the origin throughout the • Large LCD readout (H=.3"/7.5mm) for easy reading.
life of battery, meaning no more zero setting or over- • SPC data output.
speed errors.
• Three year continuous operation with a single SR44
battery. (293-676)
Specifications
Quickmike
Order No. 293-676 293-677 293-678 293-679
Measuring Range 0–1.2"(0–30mm) 1–2.2"(25–55mm) 2–3.2"(50–80mm) 3–4.2"(75–105mm)
Resolution .00005"/0.001mm
Accuracy ±.0001" ±.0002"
Quantizing error ±1 count
Measuring Faces Carbide
Flatness .000012" or less
Parallelism .00008" or less .00012" or less
Measuring Force 5–10N (500–1000gf)
Battery Life 3 years 1 year under normal use (SR-44 1pc)
Display LCD (character height .3"/7.5mm)
Functions • Origin setting • Data Hold
• Inch/Metric Conversion • SPC output
Remarks Standard Accessories: Silver oxide cell (SR-44) 1 pc.
Ratchet Friction Thimble Type.
Mass .61 lbs .78 lbs. 1.16 lbs. 1.38 lbs
For SPC output order connecting cable 937387 (1m) or 965013 (2m).
Replacement Battery: 541980 (1pc.), 541980-10 (10pcs/SET).
L-4
L-05 (2003) full size 12/11/03 12:21 PM Page 1
MICROMETERS
Digimatic Micrometers
Series 293 – with or without SPC output
293-340
Ratchet Stop
293-344
New Ratchet-Friction Thimble
(Internal “clicking” ratchet
mechanism) 293-771
Larger Size Models
(12-13" and above)
feature an alternate
Digimatic Head which
rotates for use in various
angles.
These models also have
ON/OFF controls and no
293-348 auto-sleep function.
Standard Friction Thimble
Features
• Extra large LCD readout. • Carbide-tipped measuring faces.
• Lightweight design and digital display allow measure- • Battery: SR44 (541980) x 1pc. for models up to 11–12"
ments to be taken with the micrometer held in one range. SR44 x 2pcs. for models of 12–13" range and
hand. above.
• Two measuring modes—ABS (absolute) and INC (incre- • Micrometers of ranges up to 4"(100mm) are “One-touch
mental)—for efficient measurement preset type”, whereas those of ranges exceeding
(with SPC output Model). 4"(100mm) are “All-digit preset type”.
• Functions available: Origin setting, Inch/mm selection, • Origin setting function (ABS mode): The origin point
Zero-setting, Data Hold only with SPC Models, Error value can be displayed with a touch of the ORIGIN
alarm, Auto-sleep, Data output. button. (It is also possible to set any value as the
• Can be linked to the SPC system. origin.)
• Three types of constant-force devices are available: • Zero setting function (INC mode)
ratchet stop, ratchet-friction thimble, and friction thimble.
Accuracy
• Flatness:
.000012"/0.3µm
• Parallelism: .00004" for models up to 2"/1µm for models
up to 50mm, .00008" for models up to 4"/2µm for models
up to 100mm, .00008"+.00004" x ( L* 4"
)" for models over
4" (*truncated after decimal pt.)/ (2+L/100)µm for models
over 100mm.
L=Maximum measuring length.
L-5
L-06 (2003) full size 12/10/03 1:48 PM Page 1
MICROMETERS
Specifications
Coolant Proof Micrometer IP65 Dust/Water Protection Level without SPC output
Inch/Metric
LCD
Order No. Range Resolution Accuracy Remarks
293-340 0–1" .00005" ±.00005" without SPC output
0–25.4mm 0.001mm Ratchet Stop
293-341 1–2" .00005" ±.00005" without SPC output
25.4–50.8mm 0.001mm Ratchet Stop
293-342 2–3" .00005" ±.00005" without SPC output
50.8–76.2mm 0.001mm Ratchet Stop
293-343 3–4" .00005" ±.0001" without SPC output
76.2–101.6mm 0.001mm Ratchet Stop
293-344 0–1" .00005" ±.00005" without SPC output
0–25.4mm 0.001mm Friction Thimble
293-345 1–2" .00005" ±.00005" without SPC output
25.4–50.8mm 0.001mm Friction Thimble
293-346 2–3" .00005" ±.00005" without SPC output
50.8–76.2mm 0.001mm Friction Thimble
293-347 3–4" .00005" ±.0001" without SPC output
76.2–101.6mm 0.001mm Friction Thimble
293-348 0–1" .00005" ±.00005" without SPC output
0–25.4mm 0.001mm Friction Thimble
293-349 0–1" .0001" ±.0001" without SPC output
0–25.4mm 0.001mm Friction Thimble
L-6
L-07 (2003) full size 12/10/03 12:28 PM Page 1
MICROMETERS
Specifications
Digimatic Micrometers—Rotating Spindle Types
Inch/Metric
LCD
Order No. Range Resolution Accuracy Remarks
293-330 0–1" .00005" ±.00005" with SPC output
0–25.4mm 0.001mm Ratchet Stop IP65
293-331 1–2" .00005" ±.00005" with SPC output and Standard
25.4–50.8mm 0.001mm Ratchet Stop IP65
293-332 2–3" .00005" ±.00005" with SPC output and Standard
50.8–76.2mm 0.001mm Ratchet Stop IP65
293-333 3–4" .00005" ±.0001" with SPC output and Standard
76.2–101.6mm 0.001mm Ratchet Stop IP65
293-751-30 4–5" .0001" ±.0001" with SPC output and Standard
101.6–127.0mm 0.001mm Ratchet Stop
293-752-30 5–6" .0001" ±.0001" with SPC output and Standard
127.0–152.4mm 0.001mm Ratchet Stop
293-753-30 6–7" .0001" ±.00015" with SPC output and Standard
152.4–177.8mm 0.001mm Ratchet Stop
293-754-30 7–8" .0001" ±.00015" with SPC output and Standard
177.8–203.2mm 0.001mm Ratchet Stop
293-755-30 8–9" .0001" ±.00015" with SPC output and Standard
203.2–228.6mm 0.001mm Ratchet Stop
293-756-30 9–10" .0001" ±.0002" with SPC output and Standard
228.6–254.0mm 0.001mm Ratchet Stop
293-757-30 10–11" .0001" ±.0002" with SPC output and Standard
254.0–279.4mm 0.001mm Ratchet Stop
293-758-30 11–12" .0001" ±.0002" with SPC output and Standard
279.4–304.8mm 0.001mm Ratchet Stop
293-771 12–13" .0001" ±.00025" with SPC output and Standard
304.8–330.2mm 0.001mm Ratchet Stop
293-772 13–14" .0001" ±.00025" with SPC output and Standard
330.2–355.6mm 0.001mm Ratchet Stop
293-773 14–15" .0001" ±.00025" with SPC output and Standard
355.6–381.0mm 0.001mm Ratchet Stop
293-774 15–16" .0001" ±.0003" with SPC output and Standard
381.0–406.4mm 0.001mm Ratchet Stop
293-775 16–17" .0001" ±.0003" with SPC output and Standard
406.4–431.8mm 0.001mm Ratchet Stop
293-776 17–18" .0001" ±.0003" with SPC output and Standard
431.8–457.2mm 0.001mm Ratchet Stop
293-777 18–19" .0001" ±.00035" with SPC output and Standard
457.2–482.6mm 0.001mm Ratchet Stop
293-778 19–20" .0001" ±.00035" with SPC output and Standard
482.6–508.0mm 0.001mm Ratchet Stop
293-335 0–1" .00005" ±.00005" with SPC output
0–25.4mm 0.001mm Friction Thimble IP65
293-336 1–2" .00005" ±.00005" with SPC output & Standard
25.4–50.8mm 0.001mm Friction Thimble IP65
Specifications
Inch/Metric (IP65)
LCD
Order No. Range Resolution Remarks
293-960 0–3" (3 pcs set) .00005" with SPC output & Standard (3 pcs Micrometer SET)
0–76.2mm 0.001mm Ratchet Stop IP65
293-961 0–4" (4 pcs set) .00005" with SPC output & Standard (4 pcs Micrometer SET)
0–101.6mm 0.001mm Ratchet Stop IP65
SPC Cable IP65: 05CZA662 (1m), or 05CZA663 (2m).
L-7
L-08 (2003) full size 12/10/03 12:27 PM Page 1
MICROMETERS
19–20" 10.74"
A B
293-344
Available 293-349
only on 293-369
these models: 293-370
Type 3 293-371
(12"–20") 1.12" 2.22" 1.97" .67" 293-372
.83"
B
A
Specifications
Metric Only Reading (No inch/mm function, metric thimble) IP65
LCD
Order No. Range Resolution Accuracy Remarks
293-230 0–25mm 0.001mm ±0.001mm with SPC output & Standard Ratchet Stop
293-231 25–50mm 0.001mm ±0.001mm with SPC output & Standard Ratchet Stop
293-232 50–75mm 0.001mm ±0.001mm with SPC output & Standard Ratchet Stop
293-233 75–100mm 0.001mm ±0.001mm with SPC output & Standard Ratchet Stop
293-234 0–25mm 0.001mm ±0.001mm with SPC output & Standard Ratchet Stop
293-235 25–50mm 0.001mm ±0.001mm with SPC output & Standard Ratchet Stop
293-236 50–75mm 0.001mm ±0.001mm with SPC output & Standard Ratchet Stop
293-237 75–100mm 0.001mm ±0.001mm with SPC output & Standard Ratchet Stop
293-238 0–25mm 0.001mm ±0.001mm with SPC output & Standard Ratchet Stop
SPC Cable IP65: 05CZA662 (1m), or 05CZA663 (2m).
Replacement Battery: 541980 (1pc), 541980-10 (10pcs/SET).
L-8
L-09 (2003) full size 12/11/03 12:08 PM Page 1
MICROMETERS
Dimensions
293-815
Ratchet Stop
293-816
Friction Thimble
Features
• Inch/Metric Key
• The world’s lightest digital micrometer .55 lbs
(250g) in weight.
• Made slim for easy access to the stepped feature as in
the line drawing shown.
• Easily measures 0 through 1”/25.4 mm with resolution
to .00005”/0.001mm
• Measuring faces carbide tipped.
• Includes a zero-set key for easy origin setting.
• A ratchet stop or friction thimble for a constant
measuring force.
• Measurement readout with large characters on the
LCD screen.
• The display stays on for the entire battery life (approxi-
mately 1.2 years).
• Battery: SR44 (1pc.) (Part no. 541980)
• No spindle clamp, no data output.
Specifications
MDC-Lite
Inch/Metric
Order No. Measuring Range LCD Resolution Accuracy at 20° Remarks
293-815 0–1"/0–25.4mm .00005"/0.001mm ±.0001"/±2µm Zero-set, inch/mm key, Ratchet Stop
293-816 0–1"/0–25.4mm .00005"/0.001mm ±.0001"/±2µm Zero-set, inch/mm key, Friction Thimble
The above accuracy does not include quantizing error. (±1 count)
L-9
L-10 (2003) full size 12/9/03 10:17 PM Page 1
MICROMETERS
406-721-30
106-101
Series 406-
Series 106-
.25" (DIA.) Spindle
.315" (DIA.) Spindle
Features Accuracy
• Non-rotating spindle eliminates torque on workpiece. • Flatness: .000012"/0.3µm
• Carbide-tipped measuring faces. • Parallelism: within .00016"/4µm for 406 series, within
• Spindle diameter 406 series: .25" (6.35mm) .00008"/2µm for 106 series
106 series: .315" (8.0mm)
• The 406 series can be linked to
the SPC system.
• Digimatic functions same as the Digimatic Outside
Micrometers series 293 at the first pages of this sec-
tion.
Specifications
Digimatic “Micron” Outside Micrometers
Inch/Metric
Order No. Range Resolution Accuracy Remarks
406-721-30 0–1" .00005" Ratchet Stop
0–25.4mm 0.001mm ±.00015"
406-722-30 1–2" .00005" Ratchet Stop
25.4–50.8mm 0.001mm ±.00015"
406-723-30 2–3" .00005" Ratchet Stop
50.8–76.2mm 0.001mm ±.00015"
406-724-30 3–4" .00005" Ratchet Stop
76.2–101.6mm 0.001mm ±.0002"
For SPC output order connecting cable 937387 (1m) or 965013 (2m). Replacement Battery: 541980 (1pc), 541980-10 (10 pcs/SET)
L-10
L-11 (2003) full size 12/9/03 10:18 PM Page 1
MICROMETERS
Dimensions
Order No. A B C D
406-721-30 7.66" 1.28" — .37"
406-722-30 9.07" 1.85" — .46"
406-723-30 10.3" 2.36" — .50"
406-724-30 11" 3.54" 0.89" —
Specifications
Inch
Order No. Range Resolution Accuracy Remarks
106-102 0–1" .0001" ±.0001" Friction Thimble
106-104 1–2" .0001" ±.0001" Friction Thimble
Metric
Order No. Range Resolution Accuracy Remarks
106-101 0–25mm 0.001mm ±0.002mm Friction Thimble
L-11
L-12 (2003) full size 12/9/03 10:18 PM Page 1
MICROMETERS
Outside Micrometers
Series 101
101-105 101-109
Features
• Satin-finished chrome frame, tapered (on the anvil side)
for hard-to-reach places.
• Carbide-tipped measuring faces.
Accuracy
• Flatness: .000024"/0.6µm
• Parallelism:
.00005" for up to .59"/1.3µm for up to 15mm, Designed to be
.00008" for up to 3"/2µm for up to 75mm, operated efficiently
.00012" for up to 4"/3µm for up to 100mm. with one hand.
• Designed to be operated efficiently with one hand.
Specifications
Outside Micrometers
Inch
Order No. Range Resolution Accuracy Remarks
101–230 0–.5" .0001" ±.0001" Ratchet Stop
101–113 0–1" .0001" ±.0001" Ratchet Stop
101–114 1–2" .0001" ±.0001" Ratchet Stop with Standard
101–119 2–3" .0001" ±.0001" Ratchet Stop with Standard
101–120 3–4" .0001" ±.00015" Ratchet Stop with Standard
101–117 0–1" .0001" ±.0001" Friction Thimble
101–118 1–2" .0001" ±.0001" Friction Thimble with Standard
101–105 0–1" .001" ±.0001" Ratchet Stop
101–106 1–2" .001" ±.0001" Ratchet Stop with Standard
101–109 0–1" .001" ±.0001" Friction Thimble
101–110 1–2" .001" ±.0001" Friction Thimble with Standard
L-12
L-13 (2003) full size 12/9/03 10:19 PM Page 1
MICROMETERS
Outside Micrometers
Series 102
102-121 102-226
C .57" 2.44"
.71"
A
B
Dimensions
Range A B C
0–1"(0-25mm) 1.02" .25" 1.08"
1–2"(25-50mm) 1.26" 2.06"
Features Accuracy
• Heat-insulated frame, tapered (on the anvil side) • Flatness:
for hard-to-reach places. .000012" for .0001" Resolution
• Carbide-tipped measuring faces. .000024" for .001" Resolution
• Inch models have fraction to decimal tables printed • Parallelism:
on the grip plates. .00004" for models up to 1"
.00008" for models up to 2"
• Metallic-Silver Chrome Powder Coating.
Specifications
Outside Micrometers
Inch
Order No. Range Graduations Accuracy Remarks
102-321 0–1" .001" ±.0001" Ratchet Stop
102-325 0–1" .001" ±.0001" Friction Thimble
102-327 0–1" .0001" ±.0001" Ratchet Stop
102-326 1–2" .001" ±.0001" Friction Thimble with standard
102-322 1–2" .001" ±.0001" Ratchet Stop with standard
102-328 1–2" .0001" ±.0001" Ratchet Stop with standard
102-323 2–3" .001" ±.0001" Ratchet Stop with standard
102-331 2–3" .0001" ±.0001" Ratchet Stop with standard
102-324 3–4" .001" ±.00015" Ratchet Stop with standard
102-332 3–4" .0001" ±.00015" Ratchet Stop with standard
Metric
Order No. Range Graduations Accuracy Remarks
102-301 0–25mm 0.01mm ±2mm Ratchet Stop
102-305 0–25mm 0.01mm ±2µm Friction Thimble
102-307 0–25mm 0.001mm ±2mm Ratchet Stop
102-306 25–50mm 0.01mm ±2µm Friction Thimble with standard
102-302 25–50mm 0.01mm ±2mm Ratchet Stop with standard
102-308 25–50mm 0.001mm ±2mm Ratchet Stop with standard
102-303 50–75mm 0.01mm ±2mm Ratchet Stop with standard
102-304 75–100mm 0.01mm ±3mm Ratchet Stop with standard
L-13
L-14 (2003) full size 12/9/03 10:19 PM Page 1
MICROMETERS
Outside Micrometers
Series 103
103-127 103-260
103-217
103-177
Features
• Carbide faces. • Flatness: 0.6µm (.000024") for models up
• Positive locking clamp.* to 300mm (12")
• Ratchet stop or Friction Thimble for exact repetitive 1µm (.00004") for models over
readings. 300mm (12")
• Baked-enamel-finished frame. • Parallelism: (2+L/100)µm [.00008+.00004 (L/4)"]*
• Clear graduations on satin-chrome finish. * L=Maximum measuring length (mm) [(inch)], Fraction
• Complete with fitted carrying case. rounded down
*Unless otherwise noted
Specifications
Outside Micrometers
Inch
Order No. Range Resolution Accuracy Remarks
103-127 0–1" .001" ±.0001" Friction Thimble type
103-259 0–1" .001" ±.0001" Ratchet Stop type
103-135 0–1" .0001" ±.0001" Friction Thimble type
103-128 1–2" .001" ±.0001" Friction Thimble type with Standard
103-136 1–2" .0001" ±.0001" Friction Thimble type with Standard
103-132 1–2" .0001" ±.0001" Ratchet stop type with Standard
L-14
L-15 (2003) full size 12/9/03 10:20 PM Page 1
MICROMETERS
Specifications
Inch
Order No. Range Resolution Accuracy Remarks
103-177 0–1" .001" ±.0001" Ratchet Stop type
103-178 1–2" .001" ±.0001" Ratchet Stop type with Standard
103-179 2–3" .001" ±.0001" Ratchet Stop type with Standard
103-180 3–4" .001" ±.00015" Ratchet Stop type with Standard
103-181 4–5" .001" ±.00015" Ratchet Stop type with Standard
103-182 5–6" .001" ±.00015" Ratchet Stop type with Standard
103-183 6–7" .001" ±.0002" Ratchet Stop type with Standard
103-184 7–8" .001" ±.0002" Ratchet Stop type with Standard
103-185 8–9" .001" ±.0002" Ratchet Stop type with Standard
103-186 9–10" .001" ±.00025" Ratchet Stop type with Standard
103-187 10–11" .001" ±.00025" Ratchet Stop type with Standard
103-188 11–12" .001" ±.00025" Ratchet Stop type with Standard
103-189H 12–13" .001" ±.0003" Ratchet Stop type without Standard
103-190H 13–14" .001" ±.0003" Ratchet Stop type without Standard
103-191H 14–15" .001" ±.0003" Ratchet Stop type without Standard
103-192H 15–16" .001" ±.00035" Ratchet Stop type without Standard
103-193H 16–17" .001" ±.00035" Ratchet Stop type without Standard
103-194H 17–18" .001" ±.00035" Ratchet Stop type without Standard
103-195H 18–19" .001" ±.0004" Ratchet Stop type without Standard
103-196H 19–20" .001" ±.0004" Ratchet Stop type without Standard
103-197H 20–21 .001" ±.0004" Ratchet Stop type without Standard
103-198H 21–22" .001" ±.00045" Ratchet Stop type without Standard
103-199H 22–23" .001" ±.00045" Ratchet Stop type without Standard
103-200H 23–24" .001" ±.00045" Ratchet Stop type without Standard
103-201H 24–25" .001" ±.0005" Ratchet Stop type without Standard
103-202H 25–26" .001" ±.0005" Ratchet Stop type without Standard
103-203 26–27" .001" ±.0005" Ratchet Stop type without Standard
103-204 27–28" .001" ±.00055" Ratchet Stop type with Standard
103-205 28–29" .001" ±.00055" Ratchet Stop type with Standard
103-206 29–30" .001" ±.00055" Ratchet Stop type with Standard
103-207 30–31" .001" ±.0006" Ratchet Stop type with Standard
103-208 31–32" .001" ±.0006" Ratchet Stop type with Standard
103-209 32–33" .001" ±.0006" Ratchet Stop type with Standard
103-210 33–34" .001" ±.00065" Ratchet Stop type with Standard
103-211 34–35" .001" ±.00065" Ratchet Stop type with Standard
103-212 35–36" .001" ±.00065" Ratchet Stop type with Standard
103-213 36–37" .001" ±.0007" Ratchet Stop type with Standard
103-214 37–38" .001" ±.0007" Ratchet Stop type with Standard
103-215 38–39" .001" ±.0007" Ratchet Stop type with Standard
103-216 39–40" .001" ±.00075" Ratchet Stop type with Standard
Order No. 103-904 (0–6" Set) Order No. 103-905 (0–12" Set)
Order No. Range Resolution Remarks Order No. Range Resolution Remarks
101-105 0–1" .001" 101-105 0–1" .001"
101-106 1–2" .001" 101-106 1–2" .001"
103-179 2–3" .001" Ratchet Stop type 103-179 2–3" .001"
103-180 3–4" .001" with 5 Standards 103-180 3–4" .001"
103-181 4–5" .001" 103-181 4–5" .001"
103-182 5–6" .001" 103-182 5–6" .001" Ratchet Stop type
103-183 6–7" .001" with 11 Standards
103-184 7–8" .001"
103-185 8–9" .001"
103-186 9–10" .001"
103-187 10–11" .001"
103-188 11–12" .001"
L-15
L-16 (2003) full size 12/9/03 10:20 PM Page 1
MICROMETERS
Outside Micrometers
.57" 1.85" .67"
.71"
Range A B Range A B
0–1"/0–25mm 1.10" 20–21" 12.08"
B 1–2"/25–50mm 1.49" 21–22" 12.08"
A
2–3"/50–75mm 1.93" 22–23" 13.07"
3–4"/75–100mm 2.36" 23–24" 13.07"
4–5"/100–125mm 3.11" 24–25" 14.05"
5–6"/125–150mm 3.70" 25–26" 14.05"
.25" 26–27" 15.04"
6–7"/150–175mm 4.17"
7–8"/175–200mm 4.64" 27–28" 15.04"
8–9"/200–225mm 5.11" 28–29" 16.10"
9–10"/225–250mm 5.63" 29–30" 16.10"
.315"
1.97" 10–11"/250–275mm 6.14" 30–31" 17.16"
1.12" .67"
11–12"/275–300mm 6.65" 31–32" 17.16"
(Measuring Range Over 12" Model)
12–13" 7.36" 32–33" 18.15"
33–34" 18.15"
.83"
13–14" 7.83"
14–15" 8.30" 34–35" 19.17"
15–16" 8.78" 35–36" 19.17"
A B .315" 36–37" 20.15"
16–17" 9.29"
17–18" 9.80" 37–38" 20.15"
18–19" 10.31" 38–39" 21.18"
19–20" 10.82" 39–40" 21.18"
Specifications
Inch
Order No. Range Resolution Accuracy Remarks
103-260 0–1" .0001" ±.0001" Ratchet Stop type
103-262 1–2" .0001" ±.0001" Ratchet Stop type with Standard
103-217 2–3" .0001" ±.0001" Ratchet Stop type with Standard
103-218 3–4" .0001" ±.00015" Ratchet Stop type with Standard
103-219 4–5" .0001" ±.00015" Ratchet Stop type with Standard
103-220 5–6" .0001" ±.00015" Ratchet Stop type with Standard
103-221 6–7" .0001" ±.0002" Ratchet Stop type with Standard
103-222 7–8" .0001" ±.0002" Ratchet Stop type with Standard
103-223 8–9" .0001" ±.0002" Ratchet Stop type with Standard
103-224 9–10" .0001" ±.00025" Ratchet Stop type with Standard
103-225 10–11" .0001" ±.00025" Ratchet Stop type with Standard
103-226 11–12" .0001" ±.00025" Ratchet Stop type with Standard
Metric
Order No. Range Resolution Accuracy Remarks
103-125 0–25mm 0.01mm ±0.002mm Friction Thimble type
103-126 25–50mm 0.01mm ±0.002mm Friction Thimble type with Standard
103-133 0–25mm 0.001mm ±0.002mm Friction Thimble type
103-134 25–50mm 0.001mm ±0.002mm Friction Thimble type with Standard
103-137 0–25mm 0.01mm ±0.002mm Ratchet Stop type
103-138 25–50mm 0.01mm ±0.002mm Ratchet Stop type with Standard
103-139-10 50–75mm 0.01mm ±0.002mm Ratchet Stop type with Standard
103-140-10 75–100mm 0.01mm ±0.003mm Ratchet Stop type with Standard
103-141-10 100–125mm 0.01mm ±0.003mm Ratchet Stop type with Standard
103-142-10 125–150mm 0.01mm ±0.003mm Ratchet Stop type with Standard
103-143-10 150–175mm 0.01mm ±0.004mm Ratchet Stop type with Standard
103-144-10 175–200mm 0.01mm ±0.004mm Ratchet Stop type with Standard
103-145-10 200–225mm 0.01mm ±0.004mm Ratchet Stop type with Standard
103-146-10 225–250mm 0.01mm ±0.005mm Ratchet Stop type with Standard
103-147-10 250–275mm 0.01mm ±0.005mm Ratchet Stop type with Standard
103-148-10 275–300mm 0.01mm ±0.005mm Ratchet Stop type with Standard
L-16
L-17 (2003) full size 12/9/03 10:21 PM Page 1
MICROMETERS
Specifications
Order No. 103-906 (6–12" Set) Order No. 103-930 (0–4" Set)
Order No. Range Resolution Remarks Order No. Range Resolution Remarks
103-183 6–7" .001" 103-177 0–1" .001"
103-184 7–8" .001" 103-178 1–2" .001" Ratchet Stop type
103-185 8–9" .001" Ratchet Stop type 103-179 2–3" .001" with Standards
103-186 9–10" .001" with Standards 103-180 3–4" .001"
103-187 10–11" .001"
103-188 11–12" .001" Order No. 103-927 (0–75mm Set)
Order No. Range Resolution Remarks
Order No. 103-907 (0–6" Set) 103-137 0–25mm 0.01mm
Order No. Range Resolution Remarks Ratchet Stop type
103-138 25–50mm 0.01mm
with Standards
103-135 0–1" .0001"
Friction Thimble type
103-139 50–75mm 0.01mm
103-136 1–2" .0001"
103-217 2–3" .0001" Order No. 103-913-20 (0–150mm Set)
Ratchet Stop type
103-218 3–4" .0001" Order No. Range Resolution Remarks
103-219 4–5" .0001"
with Standards 103-137 0–25mm 0.01mm
103-220 5–6" .0001"
103-138 25–50mm 0.01mm
103-139 50–75mm 0.01mm Ratchet Stop type
Order No. 103-908 (0–12" Set) 103-140 75–100mm 0.01mm with Standards
Order No. Range Resolution Remarks 103-141 100–125mm 0.01mm
103-135 0–1" .0001" 103-142 125–150mm 0.01mm
Friction Thimble type
103-136 1–2" .0001"
103-217 2–3" .0001" Order No. 103-914-20 (0–300mm Set)
103-218 3–4" .0001" Order No. Range Resolution Remarks
103-219 4–5" .0001"
103-220 5–6" .0001" 103-137 0–25mm 0.01mm
103-221 6–7" .0001" Ratchet Stop type 103-138 25–50mm 0.01mm
103-222 7–8" .0001" with Standards 103-139 50–75mm 0.01mm
103-223 8–9" .0001" 103-140 75–100mm 0.01mm
103-224 9–10" .0001" 103-141 100–125mm 0.01mm
103-225 10–11" .0001" 103-142 125–150mm 0.01mm Ratchet Stop type
103-226 11–12" .0001" 103-143 150–175mm 0.01mm with Standards
103-144 175–200mm 0.01mm
103-145 200–225mm 0.01mm
Order No. 103-909 (6"–12" Set) 103-146 225–250mm 0.01mm
Order No. Range Resolution Remarks 103-147 250–275mm 0.01mm
103-221 6–7" .0001" 103-148 275–300mm 0.01mm
103-222 7–8" .0001"
103-223 8–9" .0001" Ratchet Stop type Order No. 103-915 (150–300mm Set)
103-224 9–10" .0001" with Standards Order No. Range Resolution Remarks
103-225 10–11" .0001"
103-226 11–12" .0001" 103-143 150–175mm 0.01mm
103-144 175–200mm 0.01mm
103-145 200–225mm 0.01mm Ratchet Stop type
Order No. 103-922 (0–3" Set) 103-146 225–250mm 0.01mm with Standards
Order No. Range Resolution Remarks 103-147 250–275mm 0.01mm
103-135 0–1" .0001" 103-148 275–300mm 0.01mm
Friction Thimble type
103-136 1–2" .0001"
103-217 2–3" .0001" Ratchet Stop type Order No. 103-932 (0–3" Set)
with Standards Order No. Range Resolution Remarks
103-113 0–1" .0001" without Spindle Lock,
Order No. 103-931 (0–4" Set) 103-114 1–2" .0001" without Ratchet Stop,
Order No. Range Resolution Remarks 103-115 2–3" .0001" with Standards
103-135 0–1" .0001"
Friction Thimble type
103-136 1–2" .0001" Order No. 103-933 (0–6" Set)
103-217 2–3" .0001" Ratchet Stop type Order No. Range Resolution Remarks
103-218 3–4" .0001" with Standards
103-113 0–1" .0001"
103-114 1–2" .0001"
Order No. 103-929 (0–3" Set) without Spindle Lock,
103-115 2–3" .0001"
without Ratchet Stop,
Order No. Range Resolution Remarks 103-116 3–4" .0001"
with Standards
103-177 0–1" .001" 103-117 4–5" .0001"
Ratchet Stop type 103-118 5–6" .0001"
103-178 1–2" .001"
with Standards
103-179 2–3" .001"
L-17
L-18 (2003) full size 12/9/03 10:21 PM Page 1
MICROMETERS
340-712-30
104-138
Features
Models 340-713
• Wide measuring range with interchangeable anvils. through 340-716 feature
• Carbide-tipped spindle. a larger Digimatic
• The 340 series can be linked to the SPC system. Micrometer Head with
swiveling face for easy Face
• Provided with Ratchet Stop for constant force. Rotates
reading at any angle.
Accuracy
Digimatic Functions
• Flatness: within .000024" /0.6µm for up to12"/300mm
within .00004"/1µm for up to 40"/1000mm Models 340-711-30 & 712-30
Inch/mm, Preset, Zero/ABS, Data Send/Hold
• Parallelism: .00008" + .00004" x ( L*
4" )/(2 + L/100)µm
(*truncated after decimal pt.) Models 340-713, 714, 715 & 716
Hold, Inch/mm, On/Off, Preset, Zero/ABS, Data Send
• Measuring Accuracy: ±(.0002" + .00005" x L* 3" )"/±(4 +
L/75)µm (*truncated after decimal pt.) Furnished Accessories
L = maximum measuring length
950657 1" Anvil Attachment for model 104-165
950656 25mm Anvil Attachment for model 104-171
Specifications
Digimatic Wide Range Outside Micrometers
Inch/Metric
LCD
Order No. Range Resolution Remarks
340-711-30 0–6" .00005" with 6 Anvils & 5 Standards
0–152.4mm 0.001mm with SPC output
340-712-30 6–12" .0001" with 6 Anvils & 6 Standards
152.4–304.8mm 0.001mm with SPC output
340-713 12–18" .0001" with 6 Anvils & 6 Standards
304.8–457.2mm 0.001mm with SPC output
340-714 18–24" .0001" with 6 Anvils & 6 Standards
457.2–609.6mm 0.001mm with SPC output
340-715 24–30" .0001" with 6 Anvils & 6 Standards
609.6–762.0mm 0.001mm with SPC output
340-716 30–36" .0001" with 6 Anvils & 6 Standards
762.0–914.4mm 0.001mm with SPC output
For SPC output order connecting cable 937387(1m) or 965013(2m).
Replacement Battery: 541980 (1pc), 541980-10 (10 pcs/SET).
L-18
L-19 (2003) full size 12/9/03 10:22 PM Page 1
MICROMETERS
6.12" (155.5mm)
.57" 1.85"
(14.5) (47)
1.1" 1.73" .67"
(27.5) (44) (17)
(6.35)
ø.25"
(6.35)
ø.25"
.06"(1.5)
.12"(3)
ø.71"
(18)
340-711-30
340-712-30
104-165
With the special 1" anvil attachment (Part No. 950657), regular 1–2" range
micrometers will measure 0–1", as well as 1–2". Carbide faced attachment can
be quickly mounted on the anvil, and securely locked by the clamp. Length of the
attachment is 1" exact, hence the micrometer can be self checked at 1".
Specifications
Wide Range Outside Micrometers
Inch
Order No. Range Resolution Remarks
104-137 0–6" .001" with 6 Anvils & 5 Standards
104-138 6–12" .001" with 6 Anvils & 6 Standards
104-201 12–18" .001" with 6 Anvils & 6 Standards
104-202 18–24" .001" with 6 Anvils & 6 Standards
104-203 24–30" .001" with 6 Anvils & 6 Standards
104-204 30–36" .001" with 6 Anvils & 6 Standards
104-205 36–42" .001" with 6 Anvils & 6 Standards
104-152 12–16" .001" with 4 Anvils & 4 Standards
104-153 16–20" .001" with 4 Anvils & 4 Standards
104-154 20–24" .001" with 4 Anvils & 4 Standards
104-155 24–28" .001" with 4 Anvils & 4 Standards
104-156 28–32" .001" with 4 Anvils & 4 Standards
104-157 32–36" .001" with 4 Anvils & 4 Standards
104-158 36–40" .001" with 4 Anvils & 4 Standards
104-165 0–2" .0001" with 1" Anvil Attachment & Standard
Metric
Order No. Range Resolution Remarks
104-142 300–400mm 0.01mm with 4 Anvils & 4 Standards
104-143 400–500mm 0.01mm with 4 Anvils & 4 Standards
104-144 500–600mm 0.01mm with 4 Anvils & 4 Standards
104-145 600–700mm 0.01mm with 4 Anvils & 4 Standards
104-146 700–800mm 0.01mm with 4 Anvils & 4 Standards
104-147 800–900mm 0.01mm with 4 Anvils & 4 Standards
104-148 900–1000mm 0.01mm with 4 Anvils & 4 Standards
104-135 0–150mm 0.01mm with 6 Anvils & 5 Standards
104-136 150–300mm 0.01mm with 6 Anvils & 6 Standards
104-171 0–50mm 0.01mm with 25mm Anvil Attachment & Standard
L-19
L-20 (2003) full size 12/9/03 10:22 PM Page 1
MICROMETERS
395-741-30
295-153
115-153
Features
• Spherical Anvil Micrometers are especially useful in measuring the wall
thickness of small parts such as sleeves, collars, tubings and various
cylindrical workpieces. They are also used to measure dimensions from
the inside of holes to outside edges. The spherical anvil contacts the
inside curved surface providing a single point contact and permitting
accurate gaging of the wall thickness to .0001".
• Ratchet thimble for constant force.
• Carbide-tipped measuring faces.
• The 395 series can be linked to the SPC system.
• Provided with a constant-force device.
• Digimatic functions same as the Digimatic Outside Micrometers series
293 at the first pages of this section.
Specifications
Digimatic Spherical Face Micrometers
Inch/Metric
LCD
Order No. Range Resolution Accuracy Remarks
395-711-30 0–1" .00005" ±.0001" Spherical anvil type
0–25.4mm 0.001mm
395-712-30 1–2" .00005" ±.0001" Spherical anvil type
25.4–50.8mm 0.001mm with Standard
395-713-30 2–3" .00005" ±.0001" Spherical anvil type
50.8–76.2mm 0.001mm with Standard
395-714-30 3–4" .00005" ±.00015" Spherical anvil type
76.2–101.6mm 0.001mm with Standard
For SPC output order connecting cable 937387(1m) or 965013(2m). Replacement Battery: 541980 (1 pc), 541980-10 (10 pcs/SET)
L-20
L-21 (2003) full size 12/9/03 10:23 PM Page 1
MICROMETERS
Specifications
Digimatic Spherical Face Micrometers
Inch/Metric
LCD
Order No. Range Resolution Accuracy Remarks
395-741-30 0–1" .00005" Spherical anvil &
±.0001"
0–25.4mm 0.001mm spindle type
395-742-30 1–2" .00005" Spherical anvil &
±.0001"
25.4–50.8mm 0.001mm spindle type with Standard
395-743-30 2–3" .00005" Spherical anvil &
±.0001"
50.8–76.2mm 0.001mm spindle type with Standard
395-744-30 3–4" .00005" Spherical anvil &
±.00015"
76.2–101.6mm 0.001mm spindle type with Standard
For SPC output order connecting cable 937387 (1m) or 965013 (2m).
Replacement Battery: 541980 (1pc.), 541980-10 (10pcs/SET).
Digimatic Spherical Face Micrometers
Metric (Metric only models have metric thimble and no inch/mm button.)
LCD
Order No. Range Resolution Accuracy Remarks
395-511-30 0–25mm 0.001mm ±0.002mm Spherical anvil type
395-512-30 25–50mm 0.001mm ±0.002mm Spherical anvil type with Standard
395-541-30 0–25mm 0.001mm ±0.002mm Spherical anvil & spindle type
395-542-30 25–50mm 0.001mm ±0.002mm Spherical anvil & spindle type with Standard
For SPC output order connecting cable 937387 (1m) or 965013 (2m).
Replacement Battery: 541980 (1pc.), 541980-10 (10pcs/SET).
Digital Spherical Face Micrometers
Inch
Order No. Range Resolution Accuracy Remarks
295-153 0–1" .0001" ±.00015" Spherical anvil type
295-253 0–1" .0001" ±.00015" Spherical anvil & spindle type
Metric
Order No. Range Resolution Accuracy Remarks
295-115 0–25mm 0.01mm ±0.003mm Spherical anvil type
295-215 0–25mm 0.01mm ±0.003mm Spherical anvil & spindle type
Spherical Face Micrometers
Inch
Order No. Range Resolution Accuracy Remarks
115-153 0–1" .0001" ±.00015" Spherical anvil type
115-253 0–1" .0001" ±.00015" Spherical anvil & spindle type
Metric
Order No. Range Resolution Accuracy Remarks
115-115 0–25mm 0.01mm ±0.003mm Spherical anvil type
115-215 0–25mm 0.01mm ±0.003mm Spherical anvil & spindle type
L-21
L-22 (2003) full size 12/9/03 10:23 PM Page 1
MICROMETERS
193-211 193-111
Features
• Mechanical counter for quick and error-free reading.
• Direct readout on the counter to .001"/0.01mm.
• Carbide-tipped measuring faces.
Accuracy
• Flatness:
Inch models .000024" for models up to 12".
Metric models 0.6µm for models up to 300 mm.
• Parallelism: 193-923
Inch Models .00008" + .00004" x ( L* 4" )
(*truncated after decimal pt.) Metric Models (2 + L/100) µm.
Specifications
Digital Outside Micrometers
Inch
Order No. Range Resolution Accuracy Remarks
193-201 0–1" .001" ±.0001" Friction Thimble
193-211 0–1" .0001" ±.0001" Friction Thimble
193-212 1–2" .0001" ±.0001" with standard, Friction Thimble
193-213 2–3" .0001" ±.0001" with standard, Ratchet Stop
193-214 3–4" .0001" ±.00015" with standard, Ratchet Stop
193-215 4–5" .0001" ±.00015" with standard, Ratchet Stop
193-216 5–6" .0001" ±.00015" with standard, Ratchet Stop
193-217 6–7" .0001" ±.0002" with standard, Ratchet Stop
193-218 7–8" .0001" ±.0002" with standard, Ratchet Stop
193-219 8–9" .0001" ±.0002" with standard, Ratchet Stop
193-220 9–10" .0001" ±.00025" with standard, Ratchet Stop
193-221 10–11" .0001" ±.00025" with standard, Ratchet Stop
193-222 11–12" .0001" ±.00025" with standard, Ratchet Stop
Note: 0–1" and 1–2" models have Friction Thimbles. All others have Ratchet Stop.
L-22
L-23 (2003) full size 12/9/03 10:24 PM Page 1
MICROMETERS
Dimensions
RANGE A B RANGE A B
0–1" 9–10"
1.02" 5.70"
0–25mm 225–250mm
1–2" 10–11"
1.26" 6.22" .315"
25mm–50mm 250–275mm
.25"
2–3" 11–12"
1.77" 6.73"
50–75mm 275–300mm
3–4"
A B 2.24"
75–100mm
4–5"
3.15"
100–125mm
5–6"
3.66"
125–150mm
6–7"
4.17" .315"
150-175mm
7–8"
4.68"
175–200mm
8–9
5.19"
200–225mm
Specifications
Digital Micrometer Sets
Inch
Order No. Range Resolution Accuracy Remarks
193-923 0–3" .0001" — with standard
193-925 0–6" .0001" — with standard
193-927 6–12" .0001" — with standard
Digital Outside Micrometers
Metric
Order No. Range Resolution Accuracy Remarks
193-111 0–25mm 0.001mm ±0.002mm
193-112 25–50mm 0.001mm ±0.002mm with standard
193-113 50–75mm 0.001mm ±0.002mm with standard
193-114 75–100mm 0.001mm ±0.003mm with standard
193-101 0–25mm 0.01mm ±0.002mm
193-102 25–50mm 0.01mm ±0.002mm with standard
193-103 50–75mm 0.01mm ±0.002mm with standard
193-104 75–100mm 0.01mm ±0.003mm with standard
193-105 100–125mm 0.01mm ±0.003mm with standard
193-106 125–150mm 0.01mm ±0.003mm with standard
193-107 150–175mm 0.01mm ±0.004mm with standard
193-108 175–200mm 0.01mm ±0.004mm with standard
193-109 200–225mm 0.01mm ±0.004mm with standard
193-110 225–250mm 0.01mm ±0.005mm with standard
193-131 250–275mm 0.01mm ±0.005mm with standard
193-132 275–300mm 0.01mm ±0.005mm with standard
Digital Outside Micrometer Sets
Metric
Order No. Range Resolution Accuracy Remarks
193-915 0–75mm 0.001mm — with standard
193-901 0–75mm 0.01mm — with standard
193-903 0–150mm 0.01mm — with standard
193-905 150–300mm 0.01mm — with standard
L-23
L-24 (2003) full size 12/9/03 10:24 PM Page 1
MICROMETERS
159-101 159-211
Metric thimble/
Inch counter
A B
Dimensions
RANGE A B
0–1" Inch thimble/
1.02" Metric counter
0–25mm
.25"
1–2"
1.26"
25mm–50mm
Features
• All measuring faces are carbide
tipped for long life.
Specifications
Digital Outside Micrometers
Inch Thimble/Metric Counter
Range Resolution
Order No. (Counter) (Counter) Accuracy Remarks
159-211 0–1" .0001" ±.0001" Friction Thimble
(0–25.4mm) (0.01mm)
159-212 1–2" .0001" ±.0001" Friction Thimble
(25.4–50.8mm) (0.01mm) with Standard
L-24
L-25 (2003) full size 12/9/03 10:25 PM Page 1
MICROMETERS
227-111 227-101
.71"
.25"
1.20"
Features
• Low Measuring Force Micrometers are specially designed for
elastic workpieces such as plastic parts.
• Constant measuring force of 1N is ensured by the spring-
loaded anvil.
• Non-rotating spindle.
• Carbide-tipped measuring faces. Technical Information
1st index line 2nd index line • Measuring with a low measur-
Accuracy ing force micrometer:
• Flatness: .000024"/0.6µm 3rd index Take the measurement when
(Stop line)
• Parallelism: (.00008" + .00004"x Pointer the pointer is between the 1st
and 2nd index lines. The point-
( L*
4" ) / (2+L/100) µm er must not pass the 3rd index
(*truncated after decimal point.)
line which indicates excessive
L = maximum measuring length
measuring force.
Specifications
Low Pressure Micrometers
Inch
Order No. Range Resolution Accuracy Remarks
227-111 0–1" .0001" ±.0001" Friction
Thimble
Metric
Order No. Range Resolution Accuracy Remarks
227-101 0–25mm 0.01mm ±0.002mm Friction
Thimble
L-25
L-26 (2003) full size 12/9/03 10:25 PM Page 1
MICROMETERS
ø1.02"
(ø26)
7.49" (190.2)
227-211 .35" .70"
(9) 1.26" (32) 2.74" (69.6) 2.10" (53.4) (17.7)
0-.6" (0-15)
(ø24.5)
ø.96"
Features
1" (25)
(ø6.35)
ø.25"
Dedicated digital type micrometer for measurement which
requires a constant/low measuring force such as the
thickness of wire, paper, plastic parts and rubber parts.
( ) METRIC
Specifications
Inch
Order No. Range LCD Accuracy Measuring Measuring Remarks
Resolution Force Force Graduation
227-211 0–.6"/ .00005"/ .0001"/ 0.5–2.5N 0.5, 1.0, 1.5, 2.0, 2.5 with Ratchet
0–15mm 0.001mm 0.002mm* Thimble
227-212 0–.6"/ .00005"/ .0001"/ 2–10N 2, 4, 6, 8, 10 without Ratchet
0–15mm 0.001mm 0.002mm* Thimble
L-26
L-27 (2003) full size 12/9/03 10:26 PM Page 1
MICROMETERS
Indicating Micrometer
Series 510
Model 0-1"(0-25mm)
510-131
Features
• New Indicating Micrometers which have improved
durability, accuracy and are easy to use.
• Water-proof structure conforms to IP-54.
• Scratch-resistant hard coated crystal.
• Easy-to-read large dial graduations. ØD
• Zero-adjustment screw on backside. Model 2-4"(25-100mm)
L
Specifications
Indicating Micrometer
Inch
Graduations Graduations Range of Total Mic. Head Indicator Indicator
Order No. Range of Head of Indicator Indicator Accuracy Accuracy Repeatability Accuracy
510-131 0-1" .00005" .00005" ±.0023" ±.0001" ±.00015" ±.00002" ±.00005"
510-132 1-2" .00005" .00005" ±.0023" ±.0001" ±.00015" ±.00002" ±.00005"
510-133 2-3" .00005" .00005" ±.0023" ±.0001" ±.00015" ±.00002" ±.00005"
510-134 3-4" .00005" .00005" ±.0023" ±.0001" ±.00015" ±.00002" ±.00005"
Metric
Graduations Graduations Range of Total Mic. Head Indicator Indicator
Order No. Range of Head of Indicator Indicator Accuracy Accuracy Repeatability Accuracy
510-121 0-25mm 0.001mm 0.001mm ±0.06mm ±2µm ±3µm ±0.4µm ±1µm
510-122 25-50mm 0.001mm 0.001mm ±0.06mm ±2µm ±3µm ±0.4µm ±1µm
510-123 50-75mm 0.001mm 0.001mm ±0.06mm ±2µm ±3µm ±0.4µm ±1µm
510-124 75-100mm 0.001mm 0.001mm ±0.06mm ±2µm ±3µm ±0.4µm ±1µm
L-27
L-28 (2003) full size 12/9/03 10:27 PM Page 1
MICROMETERS
Features
• New Indicating Micrometers which have improved
durability, accuracy and easy to use.
• Water-proof structure conforms to IP-54.
• Scratch-resistant hard coated crystal. 523-121
• Easy-to-read large dial graduations.
• Zero-adjustment screw on backside.
• Measuring force: 5 to 10N.
(10.8)
Ø.43"
D
Range D L
0-1" (0-25mm) .98" (25mm) 1.22" (31mm)
1-2" (25-50mm) 1.38" (35mm) 2.20" (56mm)
2-3" (50-75mm) 1.87" (47.5mm) 3.19" (81mm)
3-4" (75-100mm) 2.45" (60mm) 4.17" (106mm)
Specifications
Dial Snap Meters
Inch
Graduations Range of Indicator Indicator Weight
Order No. Range of Indicators Indicator Repeatability Accuracy lb / g
523-131 0–1" .00005" ±.0023" ±.00002" ±.00005" 1.63 / 740
523-132 1–2" .00005" ±.0023" ±.00002" ±.00005" 1.85 / 840
523-133 2–3" .00005" ±.0023" ±.00002" ±.00005" 2.09 / 950
523-134 3–4" .00005" ±.0023" ±.00002" ±.00005" 2.38 / 1080
Metric
Graduations Range of Indicator Indicator Weight
Order No. Range of Indicators Indicator Repeatability Accuracy lb / g
523-121 0–25mm 0.001mm ±0.06mm ±0.4µm ±1µm 1.63 / 740
523-122 25–50mm 0.001mm ±0.06mm ±0.4µm ±1µm 1.85 / 840
523-123 50–75mm 0.001mm ±0.06mm ±0.4µm ±1µm 2.09 / 950
523-124 75–100mm 0.001mm ±0.06mm ±0.4µm ±1µm 2.38 / 1080
L-28
L-29 (2003) full size 12/9/03 10:28 PM Page 1
MICROMETERS
324-511-30
Features
• Measures over-pin diameter of gears with precision steel
(carbide) ball-tipped measuring faces.
Interchangeable Ball Anvils (Optional)
• Interchangeable balls anvils for various gear modules
Order No. Diameters Gears to be measured
(0.5–5.25) are optional.
of ball anvils Module Diametral
• With Ratchet Stop for constant force. pitch
• Provided with a standard except for 25mm (1") model. 124-801* 0.8mm 0.5–0.55 50
124-802* 1mm 0.6–0.65 45
Specifications 124-803* 1.191mm(3/64") 0.7–.08 35–30
Digimatic Gear Tooth Micrometers 124-821* 1.5mm 0.9–1 28–26
Metric 124-804* 1.588mm(1/16") 0.9–1 28–26
Order No. Range Resolution Accuracy 124-805 2mm 1.25 22
324-511-30 0–25mm 0.001mm ±4µm 124-806 2.38mm(3/32") 1.5 17
324-512-30 25–50mm 0.001mm ±4µm 124-822 2.5mm 1.5 17
324-513-30 50–75mm 0.001mm ±4µm 124-807 3mm 1.75 15
324-514-30 75–100mm 0.001mm ±5µm 124-808 3.175mm(1/8") – 14
124-823 3.5mm 2 13
Inch/Metric 124-823 3.5mm 2 13
Order No. Range Resolution Accuracy
124-809 3.969mm(5/32") 2 13
324-711-30 0–1" .00005"/0.001mm ±.0002"
124-810 4mm 2.25 11
324-712-30 1–2" .00005"/0.001mm ±.0002"
124-824 4.5mm 2.5 10
324-713-30 2–3" .00005"/0.001mm ±.0002"
124-811 4.763mm(3/16") 2.5 10
324-714-30 3–4" .00005"/0.001mm ±.00025"
124-812 5mm 2.75 9
124-813 5.556mm(7/32") 3.0–3.25 8
Gear Tooth Micrometers 124-814 6mm 3.5 7
Metric 124-815 6.35mm(1/4") 3.75 7
Order No. Range Resolution Accuracy 124-816 7mm 4.0 6.5
124-173 0–25mm 0.001mm ±4µm 124-817 7.144mm(9/32") 4.25 6
124-174 25–50mm 0.001mm ±4µm 124-818 7.938mm(5/16") 4.5 5.5
124-175 50–75mm 0.001mm ±4µm 124-819 8mm 4.75 5.5
124-176 75–100mm 0.001mm ±5µm 124-820 8.731mm(11/32") 5.0–5.25 5
*Carbide tipped anvil
L-29
L-30 (2003) full size 12/9/03 10:30 PM Page 1
MICROMETERS
Micrometer with a
graduation of .00005
Vertically,
Adjustable
Platform
for positioning Locking clamp holds
Features and supporting micrometer accurately
• Fast and accurate method threaded parts in place
of thread measuring avail- and plug gages
between anvil
able for use with of micrometer
Micrometer
Base Assembly
L-30
L-31 (2003) full size 12/9/03 10:30 PM Page 1
MICROMETERS
326-711-30
226-125
(mounted on optional Anvils)
Specifications
Digimatic Screw Thread Micrometers
Inch/Metric (No Anvils)
LCD
Order No. Range Resolution Accuracy Remarks
326-711-30 0–1" .00005" ±.0002"
0–25.4mm 0.001mm
326-712-30 1–2" .00005" ±0002" with Standard
25.4–50.8mm 0.001mm
326-713-30 2–3" .00005" ±.0002" with Standard
50.8–76.2mm 0.001mm
326-714-30 3–4" .00005" ±.00025" with Standard
76.2–101.6mm 0.001mm
For SPC output order connecting cable 937387(1m) or 965013(2m). Replacement Battery: 541980 (1pc), 541980-10 (10 pcs/SET)
L-31
L-32 (2003) full size 12/9/03 10:31 PM Page 1
MICROMETERS
.37 " .71" .96" 1.85" .67" .37 " .71" .57" 1.85" .67"
.71"
.71"
A B A
B
Dimensions
Range A B
0–1" .98"
.25"
Specifications 1–2" 1.30"
L-32
L-33 (2003) full size 12/9/03 10:31 PM Page 1
MICROMETERS
Pana-Mike
Series 116 – Interchangeable Anvil Type
Outside Micrometer with Non-Rotating Spindle
116-105
Shown with optional screw thread anvils.
.25"
.71"
.47"
A
Dimensions
Range A
0–1" .98"
1–2" 1.30"
Specifications
Pana-Mike
Inch (Micrometer only)
Order No. Range Resolution Accuracy Remarks
116-105 0–1" .001" ±.0002"
116-106 1–2" .001" ±.0002" with Standard
L-33
L-34 (2003) full size 12/9/03 10:32 PM Page 1
MICROMETERS
121-155 Standard
accessory
Optional Accessories
for Digimatic Bench Micrometers
Features
• Digimatic micrometer face rotates for use
in horizontal or vertical position.
• Provided with Ratchet Stop for constant
force.
• The data output function allows
a link to the SPC system.
• Standard Accessories:
1" Standard bar
Flat table (except on 121-155)
Flat tips (121-355) Batteries supplied.
Digimatic Functions:
Hold Preset
Inch/mm Zero/ABS
On/Off Data send
Specifications 121-355
Digimatic Bench Micrometers
Inch/Metric
LCD
Order No. Range Resolution Accuracy Remarks
121-155 0–2" .00005" ±.0001" with SPC output
0–50.8mm 0.001mm
121-255 0–2" .00005" ±.0001" Fixed, Flat Anvil*
0–50.8mm 0.001mm with SPC output
121-355 0–2" .00005" ±.0001" With option for series 116
0–50.8mm 0.001mm interchangeable anvils*
with SPC output
For SPC output order connecting cable 937387 (1m) or 965013 (2m).
*Can accept 121-002 Low Measuring Force Unit, and comes with 1" extension anvil.
L-34
L-35 (2003) full size 12/9/03 10:32 PM Page 1
MICROMETERS
143-121 343-511-30
C
.680" .118"
.23" E F
D
.71"
.51"
Features
• Carbide-tipped measuring faces.
• Provided with Ratchet Stop for
constant force.
Accuracy
• Flatness: .000012"
Dimensions
• Parallelism: Range A B C D E F
.00012" + .00004" x ( L*
3" ) inch 143-121 2.35"
.315"
(*truncated after decimal pt.) 143-122 3.33"
L = maximum measuring length 343-511-30 2.35"
343-711-30 1.12" 2.35" .13" .49" 1.01"
343-712-30 3.33" .25"
Specifications 343-713-30 4.32"
343-714-30 5.30"
Digimatic Caliper Type Micrometers
Inch/Metric
Order No. Range Resolution Accuracy Remarks
343-711-30 0–1" (0-25mm) .00005"/0.001mm ±.00025"
343-712-30 1–2" (25-50mm) .00005"/0.001mm ±.0003" with Standard
343-713-30 2–3" (50-75mm) .00005"/0.001mm ±.00035" with Standard
343-714-30 3–4" (75-100mm) .00005"/0.001mm ±.0004" with Standard
Metric
Order No. Range Resolution Accuracy Remarks
343-511-30 0–25mm .001mm ±5µ
L-35
L-36 (2003) full size 12/9/03 10:33 PM Page 1
MICROMETERS
Tubing Micrometers
Series 395, 295, 115 – Spherical or Cylindrical
Anvil-Perpendicular
395-733-30 115-313
395-734-30 115-314
.315"/8mm
.530"
1" to Frame
Specifications
Digimatic Tubing Micrometers
Inch/Metric
LCD
Order No. Range Resolution Accuracy Remarks
395-733-30 0–1" .00005" ±.00015" Anvil type: B
0–25.4mm 0.001mm
395-734-30 0–1" .00005" ±.00015" Anvil type: A
0–25.4mm 0.001mm
For SPC output order connecting cable 937387(1m) or 965013(2m). Replacement Battery: 541980 (1pc), 541980-10 (10pcs/SET).
Digital Tubing Micrometers
Inch
Order No. Range Resolution Accuracy Remarks
295-313 0–1" .0001" ±.00015" Anvil type: B
295-314 0–1" .0001" ±.00015" Anvil type: A
Tubing Micrometers
Inch
Order No. Range Resolution Accuracy Remarks
115-313 0–1" .0001" ±.00015" Anvil type: B
115-314 0–1" .0001" ±.00015" Anvil type: A
Metric
Order No. Range Resolution Accuracy Remarks
115-308 0–25mm 0.01mm ±0.003mm Anvil type: C
L-36
L-37 (2003) full size 12/9/03 10:34 PM Page 1
MICROMETERS
Blade Micrometers
Series 422, 122 – Non-Rotating Spindle
422-312-30 422-311-30
MDC Type MDC Type
122-101
122-125
Features
422-411
• The anvil and the spindle have a blade for measuring
the groove diameter of shafts, keyways, and other hard-
to-reach portions. Accuracy
• Non-rotating spindle. • Parallelism: .00012" for models up to 2", .00012" +
• The 422 series provides digital readout to .00004" x ( L*
4" ) for over 2", 3µm models for up to
.00005"/0.001mm and can be linked to the SPC system. 50mm, (3 + L/100)µm for models over 50mm.
• MDC Digimatic functions same as the Digimatic Outside (*truncated after decimal point).
Micrometers series 293 at the first pages of this section. L = maximum measuring length
• All Digimatic models provide SPC output. See order
table for cable.
• Quickmike Digimatic types provide Absolute encoder
sensor that tracks spindle position eliminating the need
for repeated zero settings.
• Quickmike Digimatic types also have a measuring range
Quickmike
.2"/5mm wider than the conventional MDC type. Type
Specifications
Digimatic Blade Micrometers (Quickmike Type) (with SPC output)
Inch/Metric
LCD
Order No. Range Resolution Accuracy Remarks
422-421 0–1.2" .00005" ±.00015" Blade Dimension: a
0–30mm 0.001mm
422-422 1–2.2" .00005" ±.00015" Blade Dimension: a
25–55mm 0.001mm
Metric
LCD
Order No. Range Resolution Accuracy Remarks
422-411 0–30mm 0.001mm ±0.003mm Blade Dimension: a
422-412 25–55mm 0.001mm ±0.003mm Blade Dimension: a
L-37
L-38 (2003) full size 12/9/03 10:34 PM Page 1
MICROMETERS
.030"
0–1" .250"
1.26" a
0–25mm
1–2"
Digimatic 2.68" .49" .315"R
.236"
25–50mm
.016"
.25" .118"
MDC Type 2–3"
3.27
50–75mm b
3–4" .315"R
.236"
3.70" .51"
.016"
75–100mm .157"
c
Carbide
.03"
.275"
d
Carbide
Specifications
Digimatic Blade Micrometers (MDC Type) (with SPC output)
Inch/Metric
LCD
Order No. Range Resolution Accuracy Remarks
422-311-30 0–1" .00005" ±.00015" Blade Dimension: a
0–25.4mm 0.001mm
422-321-30 0–1" .00005" ±.00015" Blade Dimension: d
0–25.4mm 0.001mm
422-351-30 0–1" .00005" ±.00015" Blade Dimension: c
0–25.4mm 0.001mm
422-312-30 1–2" .00005" ±.00015" Blade Dimension: a
25.4–50.8mm 0.001mm
422-313-30 2–3" .00005" ±.00015" Blade Dimension: a
50.8–76.2mm 0.001mm
422-314-30 3–4" .00005" ±.0002" Blade Dimension: a
76.2–101.6mm 0.001mm
422-341-30 0–1" .00005" ±.00015" Blade Dimension: b
0–25.4mm 0.001mm
422-342-30 1–2" .00005" ±.00015" Blade Dimension: b
25.4–50.8mm 0.001mm
*For SPC output order connecting cable 937387 (1m) or 965013 (2m).
L-38
L-39 (2003) full size 12/9/03 10:35 PM Page 1
MICROMETERS
.71"
.47"
1.93" .59"
25–50mm
2–3" .236" .315"
2.36"
A B C 50–75mm
3–4"
3.11" .69"
75–100mm
Specifications
Blade Micrometer
Inch
Order No. Range Resolution Accuracy Remarks
122-125 0–1" .0001" ±.00015" Blade Dimension: a
122-126 1–2" .0001" ±.00015" Blade Dimension: a
122-127 2–3" .0001" ±.00015" Blade Dimension: a
122-128 3–4" .0001" ±.0002" Blade Dimension: a
122-135 0–1" .0001" ±.00015" Blade Dimension: b
122-151 0–1" .0001" ±.00015" Blade Dimension: c
(carbide)
Metric
Order No. Range Resolution Accuracy Remarks
122-101 0–25mm 0.01mm ±0.003mm Blade Dimension: a
122-102 25–50mm 0.01mm ±0.003mm Blade Dimension: a
122-103 50–75mm 0.01mm ±0.003mm Blade Dimension: a
122-104 75–100mm 0.01mm ±0.004mm Blade Dimension: a
L-39
L-40 (2003) full size 12/9/03 10:35 PM Page 1
MICROMETERS
Uni-Mike
Series 317, 117 – Interchangeable Anvil Type
317-711-30 117-101
(1.5mm)
120°
.059"
.118" (3mm) DIA.
.098" (2.5mm)
.118" (3mm)
8" 8"
.24 mm) .24 mm)
(6.3 (6.3
Features Accuracy
• Measures tube thickness, shoulder-edge • Flatness:
distance, rivet head height, etc. with inter- Measuring face of spindle: .000024"/0.6µm
changeable anvils (flat anvil, rod anvil, V- Bottom of base: .00008"/2µm
anvil).
• Parallelism: .00012"/3µm
• The 317 series provides digital readout to
With special Disc Anvil 950758 (shown in
.00005"/0.001mm and can be linked to the
photo). The Uni-Mike is used as a height
SPC system.
micrometer. The disc has a lapped, mirror
• Digimatic functions same as the Digimatic surface.
Outside Micrometer series 293 at the first
pages of this section.
Specifications
Digimatic Uni-Mike
Inch/Metric
LCD
Order No. Range Resolution Accuracy
Remarks
317-711-30 0-1"/0-25.4mm .00005"/0.001mm ±.0002"
Friction Thimble with Flat & Rod Anvils
317-712-30 1-2"/25.4-50.8mm .00005"/0.001mm ±.0002"
Friction Thimble with Flat & Rod Anvils
plus Standard
*For SPC output order connecting cable 937387 (1m) or 965013 (2m). Replacement Battery: 541980 (1 pc), 541980-10 (10 pcs/SET)
Uni-Mike
Inch
Order No. Range Resolution Accuracy Remarks
117-107* 0–1" .0001" ±.0002" with Flat and Rod Anvils
117-108* 1–2" .0001" ±.0002" with Flat and Rod Anvils plus Standard
Metric
Order No. Range Resolution Accuracy Remarks
117-101 0–25mm 0.01mm ±.0.004mm with Flat and Rod Anvils
117-102 25–50mm 0.01mm ±.0.004mm with Flat and Rod Anvils plusStandard
*117-107 and 117-108 with Friction Thimble, others with Ratchet Stop.
L-40
L-41 (2003) full size 12/9/03 10:36 PM Page 1
MICROMETERS
Point Micrometers
Series 342, 142, 112
342-741-30 142-225
15° 30°
A A
112-189 L L
Features
• Pointed spindle and anvil for measuring the web thick- • Models with carbide-tipped measuring faces are also
ness of drills, small grooves, and other hard-to-reach available. (All models in the 342 series and the models
dimensions. in the 112 series that are marked with an *.)
• Radius of curvature of measuring points: .012"(0.3mm) • Digimatic functions same as the Digimatic Outside
• The 342 series provides digital readout to Micrometers series 293 at the first pages of this section.
.00005"/0.001mm and can be linked to the SPC system. • Replacement Battery: 541980 (1pc), 541980-10
• Provided with Ratchet Stop for constant force. (10pcs/SET)
Specifications
Digimatic Point Micrometers
Inch/Metric
LCD
Order No. Range Resolution Accuracy Remarks
342-711-30 0–1" .00005" ±.0001" with SPC output & Carbide points.
0–25.4mm 0.001mm A=15°, L=.394"
342-712-30 1–2" .00005" ±.0001" with SPC output & Standard
25.4–50.8mm 0.001mm with Carbide points. A=15°, L=.394"
342-713-30 2–3" .00005" ±.0001" with SPC output & Standard
50.8–76.2mm 0.001mm with Carbide points. A=15°, L=.394"
342-714-30 3–4" .00005" ±.00015" with SPC output & Standard
76.2–101.6mm 0.001mm with Carbide points. A=15°, L=.394"
342-741-30 0–1" .00005" ±.0001" with SPC output & Carbide points.
0–25.4mm 0.001mm A=30°, L=.430"
342-742-30 1–2" .00005" ±.0001" with SPC output & Standard
25.4–50.8mm 0.001mm with Carbide points. A=30°, L=.430"
342-743-30 2–3" .00005" ±.0001" with SPC output & Standard
50.8–76.2mm 0.001mm with Carbide points. A=30°, L=.430"
342-744-30 3–4" .00005" ±.00015" with SPC output & Standard
76.2–101.6mm 0.001mm with Carbide points. A=30°, L=.430"
All above micrometers come with Ratchet Stop and SPC output. For SPC output, order Connecting Cable 937387 (1m) or 965013 (2m).
L-41
L-42 (2003) full size 12/9/03 10:36 PM Page 1
MICROMETERS
1.00" 1.85" .67"
.25"
.25"
.71"
1.28"
.57" 1.85" .67"
.25"
Digital Type
.71"
A
Digimatic Type Dimensions
Digimatic Type Mechanical Type
Range A Range A
0–1"
1.26" 0–1" 1.50"
0–25mm
1–2"
1.85" 1–2" 1.93"
25–50mm
2–3" 2.36"
Point Micrometers
Inch
Order No. Range Resolution Accuracy Remarks
112-177 0–1" .001" ±.00015" without carbide points A=15°, L=.394"
112-225 0–1" .001" ±.00015" without carbide points A=30°, L=.430"
112-178 1–2" .001" ±.00015" without carbide points A=15°, L=.394",
with Standard
112-226 1–2" .001" ±.00015" without carbide points A=30°, L=.430",
with Standard
112-189 0–1" .001" ±.00015" with carbide points A=15°, L=.394"
112-237 0–1" .001" ±.00015" with carbide points A=30°, L=.430"
112-190 1–2" .001" ±.00015" with carbide points A=15°, L=.394",
and Standard
112-238 1–2" .001" ±.00015" with carbide points A=30°, L=.430",
and Standard
Metric
Order No. Range Resolution Accuracy Remarks
112-153 0–25mm 0.01mm ±0.003mm without carbide points A=15°, L=10mm
112-201 0–25mm 0.01mm ±0.003mm without carbide points A=30°, L=11mm
L-42
L-43 (2003) full size 12/9/03 10:37 PM Page 1
MICROMETERS
Spline Micrometers
Series 331, 131, 111
331-742-30
131-166
111-166
Features
• The anvil and spindle have a small diameter for mea-
suring splined shafts, slots, and keyways. Accuracy
• The 331 series provides digital readout to • Flatness:
.00005"/0.001mm and can be linked to the SPC Inch Models within .000012" Metric Models within
system. 0.3µm
• Carbide-tipped measuring faces. • Parallelism:
• Provided with Ratchet Stop for constant force. Inch Models .00008" + .00004" x ( L*
4" ) (*truncated
• Digimatic functions same as the Digimatic Outside after decimal point.)
Micrometers series 293 at the first pages of this Metric Models (2+L/100) µm *L=Maximum measuring
section. length.
Specifications
Digimatic Spline Type
Inch/Metric
LCD
Order No. Range Resolution Accuracy Remarks
331-711-30 0–1" .00005" ±.0001" with SPC output,
0–25.4mm 0.001mm Spline (DIA) .118" (3mm)
331-712-30 1–2" .00005" ±.0001" with SPC output & Standard,
25.4–50.8mm 0.001mm Spline (DIA) .118" (3mm)
331-713-30 2–3" .00005" ±.0001" with SPC output & Standard,
50.8–76.2mm 0.001mm Spline (DIA) .118" (3mm)
331-714-30 3–4" .00005" ±.00015" with SPC output & Standard,
76.2–101.6mm 0.001mm Spline (DIA) .118" (3mm)
331-741-30 0–1" .00005" ±.0001" with SPC output,
0–25.4mm 0.001mm Spline (DIA) .079" (2mm)
331-742-30 1–2" .00005" ±.0001" with SPC output & Standard,
25.4–50.8mm 0.001mm Spline (DIA) .079" (2mm)
331-743-30 2–3" .00005" ±.0001" with SPC output & Standard,
50.8–76.2mm 0.001mm Spline (DIA) .079" (2mm)
331-744-30 3–4" .00005" ±.00015" with SPC output & Standard,
76.2–101.6mm 0.001mm Spline (DIA) .079" (2mm)
All above micrometers come with Ratchet Stop and SPC output. For SPC output, order Connecting Cable 937387 (1m) or 965013 (2m).
Replacement Battery: 541980 (1pc), 541980-10 (10pcs/SET).
L-43
L-44 (2003) full size 12/9/03 10:37 PM Page 1
MICROMETERS
1.00" 1.85" .67"
.25"
.25"
.71"
1.28"
A Dimensions
Digimatic Type Mechanical Type
Range A Range A
0–1" 0–1"
1.26" 1.50"
0–25mm 0–25mm
1–2"
1.85" 25-50 mm 1.93"
25–50mm
2–3" 2.36"
3–4" 3.54"
Specifications
Digimatic Spline Micrometer
Metric (Metric only models have metric thimble and no inch/mm button.)
Order No. Range Resolution Accuracy Remarks
331-511-30 0–25mm 0.001mm ±0.002mm with SPC Output
Spline (DIA) 3mm
331-512-30 25–50mm 0.001mm ±0.002mm with SPC Output & Standard
Spline (DIA) 3mm
For SPC output order connecting cable 937387(1m) or 965013(2m).
Spline Micrometer
Inch
Order No. Range Resolution Accuracy Remarks
111-166 0–1" .0001" ±.00015" Spline (DIA) .118"
Metric
Order No. Range Resolution Accuracy Remarks
111-115 0–25mm 0.01mm ±0.003mm Spline (DIA) 3mm
111-116 25–50mm 0.01mm ±0.003mm Spline (DIA) 3mm
L-44
L-45 (2003) full size 12/9/03 10:38 PM Page 1
MICROMETERS
Disc Micrometers
Series 323, 223, 123 – Rotating Spindle Type
323-711-30 123-125
.787"
123-126
.03"
.315"
Accuracy
Range Flatness Parallelism
0–2" .00004" .00016"
3–4" .00004" .00016" + .00004" x ( L*
2" ) (*truncated after decimal point.)
5–12" .000063" .0002" + .00004" x ( L*
3" ) (*truncated after decimal
point.)
0–50mm 1µm 4µm
75–100mm 1µm (4 + L/50)µm
125–300mm 1.6µm (5 + L/75)µm
*L = maximum measuring length
Specifications
Digimatic Disc Micrometers
Inch/Metric
LCD
Order No. Range Resolution Accuracy Remarks
323-711-30 0–1" .00005" ±.0002" Disc Diameter: .79"
0–25.4mm 0.001mm
323-712-30 1–2" .00005" ±.0002" Disc Diameter: .79"
25.4–50.8mm 0.001mm with Standard
323-713-30 2–3" .00005" ±.0003" Disc Diameter: .79"
50.8–76.2mm 0.001mm with Standard
323-714-30 3–4" .00005" ±.0003" Disc Diameter: .79"
76.2–101.6mm 0.001mm with Standard
Metric (Metric only models have metric thimble and no inch/mm button.)
LCD
Order No. Range Resolution Accuracy Remarks
323-511-30 0–25mm 0.001mm ±0.004mm Disc Diameter: 20mm
323-512-30 25–50mm 0.001mm ±0.004mm Disc Diameter: 20mm with Standard
For SPC output order connecting cable 937387(1m) or 965013(2m). Replacement Battery: 541980 (1pc), 541980-10 (10pcs/SET).
L-45
L-46 (2003) full size 12/9/03 10:38 PM Page 1
MICROMETERS
.57" 1.85" .67"
1.67" 1.85" .67"
.23"
.23"
.25"
.25"
.71"
.71"
A
A
Dimensions
Digimatic type Mechanical type
Range A Range A
0–1" 0–1"
.98" .98"
0–25mm 0–25mm
1–2" 1–2"
1.26" 1.26"
25mm–50mm 25–50mm
2–3"
2–3" 2.68" 1.93"
50–75mm
3–4"
3–4" 3.25" 2.48"
75–100mm
100–125mm 3.11"
150–175mm 4.17"
175–200mm 4.64"
Specifications
Digital Disc Micrometers
Inch
Order No. Range Graduation Accuracy Remarks
223-125 0–1" .001" ±.0002" Disc Diameter: .79"
Metric
Order No. Range Graduation Accuracy Remarks
223-101 0–25mm 0.01mm ±0.004mm Disc Diameter: 20mm
Disc Micrometers
Inch
Order No. Range Graduation Accuracy Remarks
123-125 0–1" .001" ±.0002" Disc Diameter: .79"
123-126 1–2" .001" ±.0002" Disc Diameter: .79" with Standard
123-127 2–3" .001" ±.0003" Disc Diameter: .79" with Standard
123-128 3–4" .001" ±.0003" Disc Diameter: .79" with Standard
Metric
Order No. Range Graduation Accuracy Remarks
123-101 0–25mm 0.01mm ±0.004mm Disc Diameter: 20mm
123-102 25–50mm 0.01mm ±0.004mm Disc Diameter: 20mm with Standard
123-103 50–75mm 0.01mm ±0.006mm Disc Diameter: 20mm with Standard
123-104 75–100mm 0.01mm ±0.006mm Disc Diameter: 20mm with Standard
123-105 100–125mm 0.01mm ±0.007mm Disc Diameter: 30mm with Standard
123-106 125–150mm 0.01mm ±0.007mm Disc Diameter: 30mm with Standard
123-107 150–175mm 0.01mm ±0.008mm Disc Diameter: 30mm with Standard
123-108 175–200mm 0.01mm ±0.008mm Disc Diameter: 30mm with Standard
L-46
L-47 (2003) full size 12/9/03 10:39 PM Page 1
MICROMETERS
Disc Micrometers
Series 369, 169 – Non Rotating Spindle Type
369-711-30
169-103
Features
• Non-rotating spindle
• The 369 series provides digital readout to .00005"/0.001mm
and can be linked to the SPC system.
• Provided with a Ratchet Stop for constant-force.
• Measures paper thickness. (169-103) 369-411
• MDC Type Digimatic functions same as the Digimatic
Outside Micrometers series 293 at the first pages of
this section.
Quickmike Features Accuracy
• Quick measurement with non-rotating spindle which advances .4"/10mm per • Flatness: within .00004"/1µm
thimble rotation. • Parallelism: within .00016"/4µm for
• ABS (absolute) sensor tracks the spindle position, eliminating the need for up to 2"/50mm, within
repeated zero setting. .00024"/6µm for up to 4"/100mm.
• Measuring range has become .2"/5mm wider than the conventional MDC type. (only 169-103 within .00012")
Specifications
Digimatic Disc Micrometers (MDC Type)
Inch/Metric
Order No. Range LCD Resolution Accuracy Remarks
369-711-30 0–1" .00005" ±.0002" Disc Diameter: .79"
0–25.4mm 0.001mm
369-712-30 1–2" .00005" ±.0002" Disc Diameter: .79"
25.4–50.8mm 0.001mm with Standard
369-713-30 2–3" .00005" ±.0003" Disc Diameter: .79"
50.8–76.2mm 0.001mm with Standard
369-714-30 3–4" .00005" ±.0003" Disc Diameter: .79"
76.2–101.6mm 0.001mm with Standard
For SPC output order connecting cable 937387 (1m) or 965013 (2m). Replacement Battery: 541980 (1pc), 541980-10 (10pcs/SET).
L-47
L-48 (2003) full size 12/9/03 10:40 PM Page 1
MICROMETERS
Disc Micrometers
Series 369, 169 – Non-Rotating Spindle Type
ø
.027" .027"
Dimensions .315"
RANGE A B RANGE A B
.016" Non-rotating
0–1" 1.28" 0–1" .98" .016" spindle
.250"
.315"
Specifications
Disc Micrometers
Inch
Order No. Range Resolution Accuracy Remarks
169-103 0–1" .001" ±.0002" Disc Diameter: .44"
For paper thickness measuring (Measuring force: 53.9KPa ±4.9KPa)
169-203 0–1" .001" ±.0002" Disc Diameter: .79"
169-204 1–2" .001" ±.0002" Disc Diameter: .79" with Standard
169-206 2–3" .001" ±.0003" Disc Diameter: .79" with Standard
169-208 3–4" .001" ±.0003" Disc Diameter: .79" with Standard
L-48
L-49 (2003) full size 12/9/03 10:40 PM Page 1
MICROMETERS
V-Anvil Micrometers
Series 314, 114 – 3 Flutes and 5 Flutes
314-711-30 314-713-30
114-135 114-202
Features
• Measures the outside diameter of cut- • Provided with a constant-force device.
ting heads (such as taps, reamers, • Digimatic functions same as the
end mills) with an odd number of Digimatic Outside Micrometers series
108°
60°
flutes. 293 at the first pages of this section.
• Carbide-tipped spindle. • Supplied with Standard.
• The 314 series provides digital read-
out to .00005"/0.001mm and can be Accuracy 3 FLUTES 5 FLUTES
linked to the SPC system. • Flatness: .000024"/0.6µm
Specifications
Digimatic V-Anvil Micrometers
3 FLUTES
Inch/Metric
LCD
Order No. Range Resolution Accuracy Remarks
314-711-30 .05"–.6" .00005" ±.0002"
1.27-15.24mm 0.001mm Anvil has Centerline Groove
314-712-30 .4"–1.0" .00005" ±.0002"
10.16-25.4mm 0.001mm Anvil has Centerline Groove
314-713-30 1"–1.6" .00005" ±.00025"
25.4-40.64mm 0.001mm Anvil has Centerline Groove
314-721-30 .05"–.6" .00005" ±.0002"
1.27-15.24mm 0.001mm Anvil has no Groove
314-722-30 .4"–1.0" .00005" ±.0002"
10.16-25.4mm 0.001mm Anvil has no Groove
For SPC output order connecting cable 937387 (1m) or 965013 (2m). Replacement Battery: 541980 (1pc), 541980-10 (10 pcs/SET)
V-Anvil Micrometers
Inch
Order No. Range Resolution No. of Flutes Accuracy Remarks
114-135 .093–1.0" .0001" 5 ±.0002" Carbide Tipped Anvil
114-163 .05–.6" .001" 3 ±.0002"
114-202 .093–1.0" .0001" 3 ±.0002" Carbide Tipped Anvil
L-49
L-50 (2003) full size 12/9/03 10:41 PM Page 1
MICROMETERS
342-431-30
.02 ± 7º)
.002 °(2
"(.04 60
)
Ø.02 ± .002"(.024)
Features
• Measures the height of crimp contacts. • Ratchet Stop for a constant force device.
• The 342 series provides digital readout to • Digimatic function same as the Digimatic Outside
.00005"/0.001mm and can be linked to the SPC Micrometers series 293 at the first pages of this section.
system.
Specifications
Crimp Height Type Digimatic Micrometer
Inch/Metric
LCD
Order No. Range Resolution Accuracy Remarks
342-431-30 0–1" .00005" ±.00015" with SPC output
0–25.4mm 0.001mm
For SPC output order connecting cable 937387(1m) or 965013(2m). Replacement Battery: 541980 (1 pc), 541980-10 (10 pcs/SET)
L-50
L-51 (2003) full size 12/9/03 10:42 PM Page 1
MICROMETERS
Hub Micrometers
Series 147
.25"
Features Accuracy
.71"
• Measures hub thickness and • Flatness: .000024" (B)
(C)
shoulders inside a bore. • Parallelism: .00008" + .00004" x (D)
• Carbide-tipped measuring faces. ( L*
4" )
• Provided with Ratchet Stop for (*truncated after decimal point.)
L = Maximum measuring length
Dimensions
constant force. Range A B C D
0–1" 1.18" .57" .33" 4.80"
1–2" 2.18" 5.79"
2–3" 3.18" .69" .43" 6.77"
3–4" 4.18" 7.76"
Specifications
Hub Micrometers
Inch
Order No. Range Resolution Accuracy Remarks
147-351 0–1" .001" ±.0001"
147-352 1–2" .001" ±.0001" with Standard
147-353 2–3" .001" ±.0001" with Standard
147-354 3–4" .001" ±.00015" with Standard
L-51
L-52 (2003) full size 12/9/03 10:42 PM Page 1
MICROMETERS
147-104 (Can Seam Mike) 147-106 (Can Seam Mike) 147-201 (Can Seam Mike)
Features
• Measures the width, height, and depth of can seams.
• 147-104 has .200" depth measuring feature.
147-402 (Wire Mike)
Specifications
Can Seam & Wire Micrometers
Inch
Order No. Range Resolution Accuracy Remarks
147-104 0–.5" .001" ±.00015" with Depth Rod/for Steel Cans
147-106 0–.5" .001" ±.00015" with Depth Rod/for Aluminum Cans
147-201 0–.5" .001" ±.00015" with Depth Rod/for Sprayer Cans
147-402 0–.4" .0001" ±.00015" with Depth Rod/for wire thickness
Specifications
Digimatic Can Seam Micrometer
Inch/Metric
Order No. Range LCD Resolution Accuracy Remarks
347-104 0–.5" .00005" ±.00015" comes with Depth Rod/
0.001mm for measuring Steel Cans
347-106 0–.5" .00005" ±.00015" comes with Depth Rod/
0.001mm for measuring Aluminum Cans
347-201 0–.5" .00005" ±.00015" comes with Depth Rod/
0.001mm for measuring Sprayer Cans
L-52
L-53 (2003) full size 12/9/03 10:43 PM Page 1
MICROMETERS
189-129
118-129
118-116
Spherical Anvil
w/Flat or
Spherical spin-
dle available.
Features
• Measures thickness of sheet metal, paper, plastic, and rubber parts.
• The 389 series provides digital readout to .00005"/0.001mm and can be Accuracy
linked to the SPC system.
Inch Models
• Carbide-tipped measuring faces. Throat
• Three combinations of measuring faces: flat-flat type, spherical-flat type, Depth Flatness Parallelism
and spherical-spherical type. 6" .000024" .00012"
• Provided with Ratchet Stop for constant force. 12" .00004" .00012"
• Digimatic functions same as the Digimatic Outside micrometers series 293 Metric Models
at the first pages of this section. Throat
Specifications Depth Flatness Parallelism
Digimatic Deep Throat Micrometers 150mm 0.6µm 3µm
Inch/Metric
LCD
Order No. Range Resolution Accuracy Depth of Throat Remarks
389-711-30 0–1"(0–25.4mm) .00005"/0.001mm ±.0002" 6"
389-731-30 0–1"(0–25.4mm) .00005"/0.001mm ±.0002" 6" spherical anvil & flat spindle
389-741-30 0–1"(0–25.4mm) .00005"/0.001mm ±.0002" 6" spherical anvil & spherical spindle
389-721-30 1–2"(25.4–50.8mm) .00005"/0.001mm ±.0002" 6" with Standard
389-732-30 1–2"(25.4–50.8mm) .00005"/0.001mm ±.0002" 6" spherical anvil & flat spindle
389-742-30 1–2"(25.4–50.8mm) .00005"/0.001mm ±.0002" 6" spherical anvil & spherical spindle
389-713 0–1"(0–25.4mm) .00005"/0.001mm ±.00025" 12"
For SPC output order connecting cable 937387(1m) or 965013(2m). Replacement Battery: 541980 (1pc), 541980-10 (10pcs/SET).
Digital Deep Throat Micrometers
Inch
Order No. Range Resolution Accuracy Depth of Throat Remarks
189-129 0–1" .0001" ±.0002" 6"
L-53
L-54 (2003) full size 12/9/03 10:44 PM Page 1
MICROMETERS
Dimensions
Order No. A B
B
118-102 150mm 6.35mm
118-107 12" .315"
118-112 6" .25"
118-120 6" .25"
A
118-129 6" .25"
189-129 6" .25"
389-711-30 6" .25"
389-713 12" .315"
389-721-30 6" .25"
389-731-30 6" .25"
389-732-30 6" .25"
389-741-30 6" .25"
389-742-30 6" .25"
Specifications
Inch
Order No. Range Resolution Accuracy Remarks
118-129 0–1" .0001" ±.0002" Depth of Throat: 6"
118-120 0–1" .0001" ±.0002" Depth of Throat: 6"
Spherical Anvil & Spherical Spindle
118-116 0–1" .0001" ±.0002" Spherical Anvil & Flat Spindle
Depth of Throat: 6"
118-107 0–1" .001" ±.00025" Depth of Throat: 12"
118-112 1–2" .001" ±.0002" Depth of Throat: 6"
Metric
Order No. Range Resolution Accuracy Remarks
118-102 0–25mm 0.01mm ±0.004mm Depth of Throat: 150mm
L-54
L-55 (2003) full size 12/9/03 10:44 PM Page 1
MICROMETERS
Micrometer Standards
Series 167
167-151
Standards for
Thread 167-150
Micrometers
167-149
167-148
167-294 167-146 167-147
These Standards are primarily used for the calibration of All Standards come with a handle which prevents expan-
micrometers. They are also used as spacing bars for sion due to body temperature.
stages, or checking the accuracy of Vernier and Dial • Heat insulating handle.
Calipers. Both ends of the standards are hardened,
ground and lapped flat to meet gaging requirements. • Flat and lapped measuring ends.
• Larger sizes are chrome plated.
Features Accuracy
• Used for zero adjustment of outside micrometers. • Flatness: within 0.3µm
Specifications • Parallelism: within 2µm
Micrometer Standards
Inch
Order No. Size Accuracy Order No. Size Accuracy Order No. Size Accuracy Order No. Size Accuracy
167–141 1" ±.00005" 167–161 21" ±.0003" 167-405 41" ±.0004" 167-425 61" ±.0004"
167–142 2" ±.0001" 167–162 22" ±.0003" 167-406 42" ±.0004" 167-426 62" ±.0004"
167–143 3" ±.0001" 167–163 23" ±.0003" 167-407 43" ±.0004" 167-427 63" ±.0004"
167–144 4" ±.0001" 167–164 24" ±.0003" 167-408 44" ±.0004" 167-428 64" ±.0004"
167–145 5" ±.00015" 167–165 25" ±.00035" 167-409 45" ±.0004" 167-429 65" ±.0004"
167–146 6" ±.00015" 167–166 26" ±.00035" 167-410 46" ±.0004" 167-430 66" ±.0004"
167–147 7" ±.00015" 167–167 27" ±.00035" 167-411 47" ±.0004" 167-431 67" ±.0004"
167–148 8" ±.00015" 167–168 28" ±.00035" 167-412 48" ±.0004" 167-432 68" ±.0004"
167–149 9" ±.0002" 167–169 29" ±.00035" 167-413 49" ±.0004" 167-433 69" ±.0004"
167–150 10" ±.0002" 167–170 30" ±.00035" 167-414 50" ±.0004" 167-434 70" ±.0004"
167–151 11" ±.0002" 167–171 31" ±.00035" 167-415 51" ±.0004" 167-435 71" ±.0004"
167–152 12" ±.00025" 167–172 32" ±.00035" 167-416 52" ±.0004" 167-436 72" ±.0004"
167–153 13" ±.00025" 167–173 33" ±.00035" 167-417 53" ±.0004" 167-437 73" ±.0004"
167–154 14" ±.00025" 167–174 34" ±.00035" 167-418 54" ±.0004" 167-438 74" ±.0004"
167–155 15" ±.00025" 167–175 35" ±.00035" 167-419 55" ±.0004" 167-439 75" ±.0004"
167–156 16" ±.00025" 167–176 36" ±.00035" 167-420 56" ±.0004" 167-440 76" ±.0004"
167–157 17" ±.00025" 167–177 37" ±.0004" 167-421 57" ±.0004" 167-441 77" ±.0004"
167–158 18" ±.00025" 167–178 38" ±.0004" 167-422 58" ±.0004" 167-442 78" ±.0004"
167–159 19" ±.0003" 167–179 39" ±.0004" 167-423 59" ±.0004" 167-443 79" ±.0004"
167–160 20" ±.0003" 167-180 40" ±.0004" 167-424 60" ±.0004"
L-55
L-56 (2003) full size 12/9/03 10:45 PM Page 1
MICROMETERS
Metric
Order No. Size Accuracy Order No. Size Accuracy
167–101 25mm ±0.0015mm 167–107 175mm ±0.0045mm
167–102 50mm ±0.002mm 167–108 200mm ±0.0050mm
167–103 75mm ±0.0025mm 167–109 225mm ±0.0055mm
167–104 100mm ±0.0030mm 167–110 250mm ±0.0060mm
167–105 125mm ±0.0035mm 167–111 275mm ±0.0065mm
167–106 150mm ±0.0040mm 167–112 300mm ±0.0070mm
Set of Standards: 167–912 1"–5" (Supplied in fitted carrying case).
167–913 1"–11" (Supplied in fitted carrying case).
TECHNICAL INFORMATION
• Permissible angle error of measuring jaw
Type Metric (Unified) Whitworth Angle Error (α α) Ø6.35
W1 ±30'
L-56
L-57 (2003) full size 12/9/03 10:45 PM Page 1
MICROMETERS
Anvil Attachments
For Outside Micrometers
To measure odd workpieces, several convenient anvil
attachments are prepared by MITUTOYO. Among them
the most often used one is the ball attachment.
The ball attachments are hardened steel balls with .200"
and .250" diameters which are placed on the .250" and
.315" diameter anvils, respectively, by rubber caps. With
these attachments, regular micrometers can measure
cylindrical wall thickness, but, .200" or .250" must be
subtracted from the readings.
Other attachments shown here are .500" in length. The
added amount must be subtracted from the reading.
Spline Type
208098
Disc Type
208102 Fit .250" Dia. Anvils and Spindles
Order No. Description Dimension
101468 Ball attachment .200" DIA. Ball
208098 Spline type .078" DIA.
208099 Comparator type .039" tip x 30°
208100 Blade type .029" thickness
208101 Knife Edge type .019" face x 30°
208102 Disc type .500" DIA. Ball
Fit .315" Dia. Anvils and Spindles
101469 Ball attachment .250" DIA.
ø.078"
ø.138"
ø.039"
30°
101468 Ball 208100 208099
(.200" Dia.) Blade Comparator .500"
101469
(.250" Dia.)
ø.029"
ø.019"
30°
L-57
L-58 (2003) full size 12/9/03 10:46 PM Page 1
MICROMETERS
Micrometer Stand
Series 156
Stand Only
156-101
.71"
1.18"
.98"
4.57"
3.15"
17.13"
1.52"
1.18"
1.57"
6.5"
About
1.18"
156-101 156-102
7"
1.10"
-.4
16
45°
2.25" (MAX)
35.83"
2.91"
.1.38"
4.72"
8.66"
1.57"
.12"
3.62" (MAX)
1.18"
About
156-103 156-105
Features Specifications
• These stands are designed to allow bench-top use with Micrometer Stand
hand micrometers or other gages which have frame Inch
area sufficient to grab onto. Order No. Description
156-101 For .5" thru 4" micrometers
156-102 For 5" thru 12" micrometers
156-103 For 13" thru 40" micrometers
156-105* For 1" & 2" micrometers
*Fixed Angle type
L-58
L-59 (2003) full size 12/9/03 10:47 PM Page 1
MICROMETERS
Groove Micrometers
Series 146
146-231 146-232
(GVM-25(1")R-100(4")R) (GVM-25(1")SR)
[Order No.146-122(132)~146-125(135)] [Order No.146-121(131)]
(ø12.7)
(ø12.7)
(ø15)
.5"
.5"
.59"
(ø6.35)
(ø15)
(ø6.35)
(ø10)
.59"
ø.25"
ø.25"
.39"
(ø10)
(ø5)
.20"
.39"
0-25mm 0-25mm
(ø3.5)
ø.14"
MADE IN JAPAN
MADE IN JAPAN
(ø6.35)
.25"
.025" .025"
(0.75) (0.75)
9.05" (229.8) 6.7" (170.3)
Features
• Flanged spindle for measuring width and location of • two-directional ratchet stop
grooves inside/outside bores and tubes. (measuring force: 0.7–1.2N).
Accuracy
• Instrumental error: ±.0004"/±10µm
• Parallelism: .0004"/10µm
OUTSIDE MEASUREMENT
20
21 45
0 9 8 7 22 254 20
SLEEVE 23 SLEEVE 3 21 9 8 76
24
GRADUATION 0 GRADUATION 0
1
INCH 5 2 METRIC 6 4 3 21 98
0 9 8 7 3
4 25 20 5
5
INSIDE MEASUREMENT
Specifications
Rotating Groove Micrometers Non-Rotating Groove Micrometers
Inch Inch
Order No. Inside Range Outside Range Resolution Order No. Inside Range Outside Range Resolution
146-131 .055–1.05" 0–1" .001" 146-231 .055–1.05" 0–1" .001"
146-132 .055–1.05" 0–1" .001" 146-232 .055–1.05" 0–1" .001"
146-133 1.05–2.05" 1–2" .001" 146-233 1.05–2.05" 1–2" .001"
146-134 2.05–3.05" 2–3" .001" 146-234 2.05–3.05" 2–3" .001"
146-135 3.05–4.05" 3–4" .001" 146-235 3.05–4.05" 3–4" .001"
Metric Metric
Order No. Inside Range Outside Range Resolution Order No. Inside Range Outside Range Resolution
146-121 1.6–26.5mm 0–25mm 0.01mm 146-221 1.6–26.5mm 0–25mm 0.01mm
146-122 1.6–26.5mm 0–25mm 0.01mm 146-222 1.6–26.5mm 0–25mm 0.01mm
146-123 26.5–51.5mm 25–50mm 0.01mm 146-223 26.5–51.5mm 25–50mm 0.01mm
146-124 51.5–76.5mm 50–75mm 0.01mm 146-224 51.5–76.5mm 50–75mm 0.01mm
146-125 76.5–101.5mm 75–100mm 0.01mm 146-225 76.5–101.5mm 75–100mm 0.01mm
L-59
L-60 (2003) full size 12/9/03 10:48 PM Page 1
TOOL KITS
LUT
SO E
AB
Y
OG
EC
H N OL
T
950-939-9 Inch/Metric 950-940-9 Inch/Metric
The Digimatic Tool Kits include Mitutoyo’s highly popular 0–1" Digimatic Micrometer (choose ratchet or friction type)
and 0–6" Digimatic Caliper with Absolute Encoder. The case is made of handsome, solid mahogany and has space
for gage batteries. The micrometer spanner is a supplied accessory.
Order No. 950-939-9 (Digimatic Tool Kit) Order No. 950-940-9 (Digimatic Tool Kit)
Item No. Description Item No. Description
293-761-30 Digimatic Micrometer (Ratchet Stop Type) 293-765-30 Digimatic Micrometer (Friction Thimble Type)
(Range: 0–1", LCD Resolution: .00005") (Range: 0–1", LCD Resolution: .00005")
500-196 Digimatic Caliper with Absolute Encoder 500-196 Digimatic Caliper with Absolute Encoder
(Range: 0–6", LCD Resolution: .0005") (Range: 0–6", LCD Resolution: .0005")
050515 Mahogany Case 050515 Mahogany Case
950-901
This Tool Kit is intended for machinists, machinist Order No. 950-901 (Inch Tool Kit)
apprentices and vocational students who are required Item No. Description
to master the use of basic measuring instruments. Each
103-127 Outside Micrometer (Friction Thimble Type)
tool is a high quality, precision product traceable to the (Range: 0–1", Resolution: .001")
NIST or meets applicable Federal specifications.
180-901 6" Combination Set
180-201 6" Flexible Steel Rule
950-221 4" Outside Spring Caliper
950-211 4" Spring Divider
950-231 4" Inside Spring Caliper
950-271 Angle Depth Gage (Adjustable)
950-201 Center Gage (according to 60°---US standards)
950-241 Hermaphrodite Caliper
950-261 Pocket Scriber
050112 Center Punch
050510 Mahogany Case
L-60
L-61 (2003) full size 12/9/03 10:48 PM Page 1
TOOL KITS
950-902 950-903
This Tool Kit contains the three most often used measuring instruments in a convenient case.
Order No. 950-902 (Inch Tool Kit) Order No. 950-903 (Inch Tool Kit)
Item No. Description Item No. Description
103-127 Outside Micrometer (Friction Thimble Type) 103-135 Outside Micrometer (Friction Thimble Type)
(Range: 0–1", Resolution: .001") (Range: 0–1", Resolution: .0001")
505-717 Dial Caliper 505-675 Dial Caliper
(Range: 0–6", Dial Resolution: .001") (Range: 0–6", Dial Resolution: .001")
182-201 6" Full-Flexible Rule (4R) 182-204 6" Full-Flexible Rule (3R)
050516 Mahogany Case 050516 Mahogany Case.
950-920 950-906
Order No. 950-920 (Inch Tool Kit) Order No. 950-906 (Inch Tool Kit)
Item No. Description Item No. Description
182-112 6" Black Steel Rule 103-127 Outside Micrometer (Friction Thimble Type)
103-105 0-1" Micrometer (Ratchet Thimble) (Range: 0–1", Resolution: .001")
505-717 0-6" Dial Caliper 180-901 6" Combination Set
050516 Mahogany Case 182-201 6" Full-Flexible Rule (4R)
505-717 Dial Caliper
(Range: 0–6", Dial Resolution: .001")
950-201 Center Gage
950-211 4" Spring Divider
950-221 4" Outside Spring Caliper
950-231 4" Inside Spring Caliper
950-241 4" Hermaphrodite Caliper
950-261 Pocket Scriber
950-271 Adjustable Angle Depth Gage
050112 Center Punch
050500 Mahogany Case
L-61
L-62 (2003) full size 12/9/03 10:49 PM Page 1
TOOL KITS
950-921 950-922
Order No. 950-921 (Tool Kit Lite) Order No. 950-922 (Tool Kit Lite)
Item No. Description Item No. Description
182-112 6" Black Steel Rule 182-112 6" Black Steel Rule
700-113 0-6"/0-150mm MyCal Lite 700-113 0-6"/0-150mm MyCal Lite
293-811 0-1"/0-25.4mm MDC Lite (Ratchet Thimble) 293-812 0-1"/0-25.4mm MDC Lite (Friction Thimble)
64PPP932 Mahogany Case 64PPP932 Mahogany Case
950-923 950-924
Order No. 950-923 (New Technology Tool Kit) Order No. 950-924 (Extreme Tool Kit)
Item No. Description Item No. Description
182-112 6" Black Steel Rule 182-112 6" Black Steel Rule
293-677 0-1.2"/0-30mm IP-54 rated Quickmike 500-652 0-6"/0-150mm IP-65 rated
500-464 0-6"/0-150mm Solar Caliper Coolant Proof Caliper
64PPP931 Mahogany Case 293-369 0-1"/0-25.4mm IP-54 rated
Water Resistant Micrometer
64PPP931 Mahogany Case
L-62
L-63 (2003) full size 12/9/03 10:50 PM Page 1
TOOL KITS
This kit goes one step further for the student machinist.
It augments the basic kit with a combination set and a
depth attachment for the dial caliper. The furnished,
fitted, mahogany carrying-case helps keep the high-
quality MITUTOYO Tools in good condition.
L-63
L-64 (2003) full size 12/9/03 10:50 PM Page 1
TOOL KITS
L-64
M-01 (2003) full size 12/11/03 3:48 PM Page 1
Micrometer Heads
Digimatic Micrometer Heads - Series 164 M-2
MICROMETER HEADS
164-162 164-172
(ø8mm)
ON/OFF ZERO/ABS in/mm
.32"
.96"
ø18 -0.011
+0
.71"
Spindle diameter:
(34mm)
(33mm)
1.34"
1.31"
.433" (11mm)
(25mm)
.67" .60"
Diameter: (16.8mm) (15mm)
.315" (8mm)
2.20"
(56mm)
These LCD reading micrometer heads provide the easiest and most efficient means of
obtaining precision measurement of linear travel on microstages and similar applications.
Typical application
on Toolmaker's
Specifications microscope.
Digimatic Micrometer Heads (with SPC output)
Inch/Metric
LCD
Order No. Range Resolution Accuracy
164-162 0–2" .00005"
±.00015"
0–50.8mm 0.001mm
164-172 0–1" .00005"
±.0001"
0–25.4mm 0.001mm
For SPC output order Connecting Cable 937387 (1m) or 965013 (2m).
M-2
M-03 (2003) full size 12/8/03 4:30 PM Page 1
MICROMETER HEADS
350-711-30 350-712-30
THREAD SIZE
.59" M9.5x0.5
NUT DIA. .55"
.16"
A: Inch/Metric models
.25"
ø.25"
350-712-30
350-714 350-711-30 & 350-712-30
0
is .375" -.0006
1.06" Metric only models
A
.157"R
DIA.
2.32"
.70"
350-511-30 &
0
350-512-30 is 10mm -0.009mm
350-711-30
6.16"
Features
• Reads to 50 millionths of an inch. • Each unit comes complete with a battery (offers 1 year
• Preset capability. This allows an operator to set any of life under normal use), key spanner, and operation
desired measurement on the display and recall that manual.
measurement with a simple push of a button. • Carbide-tipped measuring face.
• Instant in/mm conversion. • Locking clamp.
• Measurement hold key. • Runs off single SR44 battery. (No. 541980)
• Zero-Set key. Allows for setting zero measurement at • Automatic power-off.
any point along the spindle travel. Note: Optional bushings available for alternate shank
• SPC output provided. diameter. 64PPP034 .5" Dia. Shank, 64PPP035 .709"
• Data Send button for transmitting readings to Dia. Shank Length of bushings is .5".
SPC system.
Specifications
Digimatic Micrometer Head (with SPC output)
Inch/Metric
LCD
Order No. Range Resolution Accuracy Remarks
350-711-30 0–1" .00005"
0–25.4mm 0.001mm ±.0001"
350-712-30 0–1" .00005"
0–25.4mm 0.001mm ±.0001" with Clamp Nut
350-713-30 0–1" .00005"
0–25.4mm 0.001mm ±.0001" Spherical Face
350-714-30 0–1" .00005" Spherical Face
0–25.4mm 0.001mm ±.0001" with Clamp Nut
Metric (Metric only models have metric thimble and no inch/mm button).
LCD
Order No. Range Resolution Accuracy Remarks
350-511-30 0–25mm 0.001mm ±0.002mm
350-512-30 0–25mm 0.001mm ±0.002mm
with Clamp Nut
For SPC output order connecting cable 937387 (1m) or 965013 (2m). Replacement Battery: 541980 (1 pc), 541980-10 (10 pcs/SET)
M-3
M-04 (2003) full size 12/8/03 4:31 PM Page 1
MICROMETER HEADS
.315"
0
110-102 45
40
.157" OVERALL
LENGTH 4.25"
Note: Where metric dimensions are given they pertain .236"
ONLY to metric models. Where no metric dimension is 1" .5"
(25) (12.5)
given the inch and metric models are identical.
(mm)
Specifications
Differential Screw Translator
Inch
Accuracy
Order No. Range Resolution Overall One Revolution Remarks
110-111 0–.05" .00005" ± .0002" ± .00006" Non-Rotating Spindle
110-112 0–.05" .000005" ± .0002" ± .00006" with Clamp Nut
Metric
Accuracy
Order No. Range Resolution Overall One Revolution Remarks
110-101 0–2.5mm 0.001mm ± 0.005mm ± 0.0015mm Non-Rotating Spindle
110-102 0–2.5mm 0.0001mm ± 0.005mm ± 0.0015mm with Clamp Nut
Micrometer Heads
Series 148
Ø 9.5 -0.009
SR4
Standard micrometer head pitch is 0.5mm per
revolution. This micrometer head can be used for fine
Ø 13
Ø5
positioning.
17.5 9.5 1.5
58.5
Specifications
Metric 148-132
Order No. Range Resolution Accuracy Remarks
148-132 0–13mm 0.01mm ±0.002mm Spherical Face 0
Ø 9.5 -0.009
SR
148-133 0–13mm 0.01mm ±0.002mm Spherical Face 4
with Clamp Nut
Ø6.35
Ø 15
18.5 23.5
42
148-322
M-4
M-05 (2003) full size 12/8/03 4:33 PM Page 1
MICROMETER HEADS
Micrometer Heads
Series 148
3.5mm -0.01mm"
148-212
)
148-204
(6mm -0.008mm"
148-215 148-216
0
-.0005"
148-211 148-207
148-203
0
148-208
.25"
Clamp Nut.
.217" .07"
.2"
M6x0.5" .118"R M3.5x0.5
.079"
.079"
.138"
.24"
.32"
.37"
.06"R
.26" .2" .04" .2"
Spherical Face
.12" .16" .45" .45"
with Clamp Nut
.3" .3" 1.26"
1.46"
148-451 148-201
( 6mm -0.008mm )
148-452 148-202
.0003"
-.0005"
148-205
148-209
0
148-206
.0
148-210 0
.25"
ø.138"
.236"
10
.138"
ø.36"
0 .118"R
.37"
40
1.46"
Specifications
Micrometer Heads Note: ( ) METRIC MODEL
Inch
Order No. Range Resolution Accuracy Remarks
148-202 0–.25" .001" ±.0002"
148-452 0–.25" .001" ±.0002"
148-204 0–.25" .001" ±.0002" with Clamp Nut
148-206 0–.25" .001" ±.0002" Spherical Face type
148-208 0–.25" .001" ±.0002" Spherical Face type, with Clamp Nut
148-210 0–.25" .001" ±.0002" Reverse Reading type
148-212 0–.25" .001" ±.0002" Reverse Reading type, with Clamp Nut
Metric
Order No. Range Resolution Accuracy Remarks
148-215 0–5.0mm 0.02mm ±0.005mm Spherical Face type
148-216 0–5.0mm 0.02mm ±0.005mm Spherical Face type, with Clamp Nut
148-201 0–6.5mm 0.01mm ±0.005mm
148-451 0–6.5mm 0.01mm ±0.005mm
148-203 0–6.5mm 0.01mm ±0.005mm with Clamp Nut
148-205 0–6.5mm 0.01mm ±0.005mm Spherical Face type
148-207 0–6.5mm 0.01mm ±0.005mm Spherical Face type, with Clamp Nut
148-209 0–6.5mm 0.01mm ±0.005mm Reverse Reading type
148-211 0–6.5mm 0.01mm ±0.005mm Reverse Reading type, with Clamp Nut
M-5
M-06 (2003) full size 12/8/03 4:36 PM Page 1
MICROMETER HEADS
148-351 148-358
148-355 148-362
148-354 148-359
The Mitutoyo MHC Micrometer Head offers easy fine-feed- compact design. It is ideal as a device to feed machine
ing and easy reading due to the large thimble diameter. tables or stages. Large diameter thimble makes fine
The MHC is simple to incorporate into machines due to its adjustments easy and provides error-free readout.
Specifications
MHC Micrometer Heads
Inch
Order No. Range Resolution Accuracy Remarks
148-351 0–.25" .001" ±.0001"
148-352 0–.25" .001" ±.0001" with Clamp Nut
148-353 0–.25" .001" ±.0001"
148-354 0–.25" .001" ±.0001" with Clamp Nut
148-355 0–.25" .001" ±.0001"
148-356 0–.25" .001" ±.0001" with Clamp Nut
148-357 0–.5" .001" ±.0001"
148-358 0–.5" .001" ±.0001" with Clamp Nut
148-359 0–.5" .001" ±.0001"
148-360 0–.5" .001" ±.0001" with Clamp Nut
148-361 0–.5" .001" ±.0001"
148-362 0–.5" .001" ±.0001" with Clamp Nut
Metric
Order No. Range Resolution Accuracy Remarks
148-301 0–6.5mm 0.01mm ±0.002mm
148-302 0–6.5mm 0.01mm ±0.002mm with Clamp Nut
148-303 0–6.5mm 0.01mm ±0.002mm
148-304 0–6.5mm 0.01mm ±0.002mm with Clamp Nut
148-305 0–6.5mm 0.01mm ±0.002mm
148-306 0–6.5mm 0.01mm ±0.002mm with Clamp Nut
148-307 0–13mm 0.01mm ±0.002mm
148-308 0–13mm 0.01mm ±0.002mm with Clamp Nut
148-309 0–13mm 0.01mm ±0.002mm
148-310 0–13mm 0.01mm ±0.002mm with Clamp Nut
148-311 0–13mm 0.01mm ±0.002mm
148-312 0–13mm 0.01mm ±0.002mm with Clamp Nut, Reverse Reading type
M-6
M-07 (2003) full size 12/8/03 4:37 PM Page 1
MICROMETER HEADS
148-301 148-302
ø.51" (13)
148-351 ø.51" (13) 148-352
0 0
ø3/8" -0005" (ø9.5" -0004")
0 0
ø3/8" -0005" (ø9.5" -0004")
M9.5x0.5
ø.25" (6.35)
ø.25" (6.35)
ø.59" (15)
ø.59" (15)
4)
.16"(4)
"(1
.37"(9.5) .08" (2)
51
.37"(9.5) .08" (2)
5
ø.
.73" (18.5) .93" (23.5) .73" (18.5) .93" (23.5)
148-303 148-304
ø.51" (13)
ø.51" (13)
148-353 148-354 0
(ø9.5"
0
0 0 ø3/8" -0005" -0004")
ø3/8" -0005" (ø9.5" -0004")
ø.25" (6.35)
M9.5x0.5
ø.25" (6.35)
ø.79" (20)
ø.79" (20)
4)
.16"(4)
(1
1"
.37"(9.5)
55
.08" (2) .37"(9.5) .08" (2)
ø. .73" (18.5) .93" (23.5)
.73" (18.5) .93" (23.5)
ø.51" (13)
ø.51" (13)
148-305 148-306
148-355 ø3/8"
0
-0005" (ø9.5"
0
-0004") 148-356 ø3/8"
0
-0005" (ø9.5"
0
-0004")
ø.25" (6.35)
ø1.14" (29)
M9.5x0.5
ø.25" (6.35)
ø1.14" (29)
4)
(1
1"
55
.16"(4)
.37"(9.5) .08" (2)
ø.
148-357 148-358 0 0
0 ø3/8" -0005" (ø9.5" -0004")
ø3/8" -0005"
0
(ø9.5 -0004") M9.5x0.5
ø.25" (6.35)
ø.25" (6.35)
ø.59" (15)
ø.59" (15)
)
14
.16"(4)
(ø
1"
148-309
ø.51" (13)
148-310
ø.51" (13)
148-359 0 148-360 0 0
ø3/8" -0005" ø3/8" -0005" (ø9.5" -0004")
0
(ø9.5 -0004")
ø.25" (6.35)
M9.5x0.5
ø.25" (6.35)
ø.79" (20)
ø.79" (20)
)
14
(ø
.16"(4)
1"
.37"(9.5)
55
.08" (2)
.37"(9.5)
ø.
.08" (2)
.98" (25) 1.18" (30) .98" (25) 1.18" (30)
148-311 148-312
ø.51" (13)
ø.51" (13)
148-361 148-362 0
(ø9.5"
0
0 ø3/8" -0005" -0004")
ø3/8" -0005"
0
(ø9.5 -0004") M9.5x0.5
ø1.14" (29)
ø.25" (6.35)
ø.25" (6.35)
ø1.14" (29)
)
14
(ø
1"
.16"(4)
55
.37"(9.5)
ø.
M-7
M-08 (2003) full size 12/8/03 4:38 PM Page 1
MICROMETER HEADS
Micrometer Heads
Series 148
M-8
M-09 (2003) full size 12/8/03 4:39 PM Page 1
MICROMETER HEADS
Micrometer Heads
148-461 148-401 148-403
148-462 148-402 148-404
.0003"
ø.375" .0005"
ø.375" .0005"
.0
.0006"
.0011"
.0
.0
ø.51"
ø.138"
.236"
ø.51"
ø.197"
ø.197"
10 10 10
5 5
ø.37"
0 0 0
45 45
40 40 40
.75" .37" 1.24" .75" .37" 1.44" .67"
.63" .24" 1.13"
2.36" 3.23"
2"
148-122 148-811
148-834 148-801
0 0
148-120 M9.5x0.5 .375" -.0005" (9.5mm -0.009mm )
148-824
.197"
.55"
.197"
.51"
148-112 148-812
148-831 0
(9.5mm 0
) 148-802
.375" -.0005" -.009mm
148-104
.197"
.197"
148-821
.51"
.69" .37"
.157"R
2.30"
148-111 148-813
148-832 0 0 148-803
M9.5x0.5 .375" (9.5mm )
.197"
-.0005"
148-103 -.009mm
.55"
.197"
.51"
.16"
.16"
.69" .37" .157"R
2.30"
148-123 148-814
148-833 0 0 148-804
.375" -.0005" (9.5mm -0.009mm)
148-121
.197"
148-823
.197"
.51"
.Spindle Lock
.69" .37" .12" .157"R
2.64"
M-9
M-10 (2003) full size 12/8/03 4:26 PM Page 1
MICROMETER HEADS
Micrometer Heads
Series 148
148-501, 148-503, 148-511
148-513, 148-861, 148-863
(9.5mm -0.009mm )
-.0005"
0
0
.375"
148-501* 148-862
.197"
Clamp Nut
.51"
.61" .37"
2.44"
*The thimble freely rotates when a hex
screw is released. This resettable fea-
ture allows easy zero reposition after
(9.5mm -0.009mm )
148-502, 148-504
the mike head is installed.
-.0005"
148-862, 148-864
0
.375"
148-502*
.55"
M9.5x0.5
.197"
Spindle Lock
.51"
Note: ( ) METRIC MODEL .16"
.61" .37"
2.80"
Specifications
(9.5mm -0.009mm )
Micrometer Heads ( with Spindle Lock) 148-505
-.0005"
148-506
0
Inch
0
.375"
.197"
Order No. Range Resolution Accuracy Remarks
148-502 0–.5" .001" ±.0001" with Clamp Nut
.51"
148-505 0–.5" .001" ±.0001"
148-852 0–.5" .001" ±.0001" with Clamp Nut .61" .37"
Spherical Face type 2.80"
)
-0.009mm
148-851
-.0005"
Metric 148-853
0
(9.5mm
.375"
.197"
.51"
148-854 0–13mm 0.01mm ±0.002mm with Clamp Nut R=.157" .61" .37"
Spherical Face type 2.44"
148-864 0–13mm 0.01mm ±0.002mm with Clamp Nut
Reverse Reading type
)
-0.009mm
-.0005"
148-852
Micrometer Heads (without Spindle Lock)
0
148-854
(9.5mm
.375"
Inch
.55"
M9.5 x 0.5
.197"
148-507
-.0005"
Metric 148-508
0
M9.5 x 0.5
148-503 0–13mm 0.01mm ±0.002mm
148-508 0–13mm 0.01mm ±0.002mm with Clamp Nut
.51"
M-10
M-11 (2003) full size 12/8/03 4:27 PM Page 1
MICROMETER HEADS
Micrometer Heads
Series 149
149-131 149-812
149-801 149-148
0
.375" -.0005
0 .157" M9.5 x 0.5
(9.5mm -0.009 )
.250" .118"
Features
• Carbide-tipped measuring face
• Optional Ratchet stop (950700) is available.
Specifications
Micrometer Heads
Inch
Order No. Range Resolution Accuracy Remarks
149-147 0–.5" .001" ±.0001" with Clamp Nut
149-148 0–.5" .001" ±.0001"
149-182 0–.5" .001" ±.0001" with Spindle Lock/with Clamp Nut
149-185 0–.5" .001" ±.0001" with Spindle Lock
149-811 0–.5" .001" ±.0001" Spherical Face Type
149-812 0–.5" .001" ±.0001" Spherical Face Type with Clamp Nut
149-831 0–.5" .001" ±.0001" Reverse Reading type
149-832 0–.5" .001" ±.0001" Reverse Reading type with Clamping Nut
Metric
Order No. Range Resolution Accuracy Remarks
149-131 0–15mm 0.01mm ±0.002mm with Clamp Nut
149-132 0–15mm 0.01mm ±0.002mm
149-183 0–15mm 0.01mm ±0.002mm with Spindle Lock
149-184 0–15mm 0.01mm ±0.002mm with Spindle Lock/with Clamp Nut
149-801 0–15mm 0.01mm ±0.002mm Spherical Face type
149-802 0–15mm 0.01mm ±0.002mm Spherical Face type with Clamp Nut
149-821 0–15mm 0.01mm ±0.002mm Reverse Reading type
149-822 0–15mm 0.01mm ±0.002mm Reverse Reading type with Clamp Nut
M-11
M-12 (2003) full size 12/15/03 10:24 AM Page 1
MICROMETER HEADS
Micrometer Heads
Series 150
150-832 150-208
0
.375"
150-208 .157"R. 0 150-812 DIA. 9.5mm
-.0005"
0
.375" -.005" ( 10mm )
150-811 150-832 -0.009
.250"
0
(10mm" -0.009 ) Pitch 0.5mm
.250"
150-831 150-191 10
5
150-190 10
5
150-802 0
150-192 0 150-822 45
40
150-801 45
40
150-821 .157" Set Lock provided
1.06" .59" .236" with this
.157"R. Micrometer Head
1.06"
4.29" .59"
4.29"
ø.5" .0007"
ø.5" .0007"
150-401 150-403
.0
.0
ø.79"
150-402 150-404
ø.71"
ø.71"
ø.25"
ø.25"
4.65" 5.1"
Features
• Carbide-tipped measuring face Note: ( ) METRIC MODEL
Specifications
Micrometer Heads
Inch
Order No. Range Resolution Accuracy Remarks
150-208 0–1" .001" ±.0001"
150-402 0–1" .001" ±.0001"
150-404 0–1" .001" ±.0001" with Spindle Lock
150-811 0–1" .001" ±.0001" Spherical Face type
150-812 0–1" .001" ±.0001" Spherical Face type with Clamp Nut
150-831 0–1" .001" ±.0001" Reverse Reading
150-832 0–1" .001" ±.0001" Reverse Reading with Clamp Nut
Metric
Order No. Range Resolution Accuracy Remarks
150-190 0–25mm 0.001mm ±0.002mm
150-401 0–25mm 0.001mm ±0.002mm
150-403 0–25mm 0.001mm ±0.002mm with Spindle Lock
150-191 0–25mm 0.01mm ±0.002mm with Clamp Nut
150-192 0–25mm 0.01mm ±0.002mm
150-801 0–25mm 0.01mm ±0.002mm Spherical Face type
150-802 0–25mm 0.01mm ±0.002mm Spherical Face type with Clamp Nut
150-821 0–25mm 0.01mm ±0.002mm Reverse Reading
150-822 0–25mm 0.01mm ±0.002mm Reverse Reading with Clamp Nut
All Series 150 Micrometer Heads are supplied with carbide measuring face and ratchet stop.
M-12
M-13 (2003) full size 12/8/03 4:30 PM Page 1
MICROMETER HEADS
Micrometer Heads
Series 151
151-238 151-237
.0006"
ø.563" .0011"
ø.83"
ø.315"
0
.500 -.0005"
.315"
0
(12mm -0.011" )
10
5
45
40
1.34" 1.14"
5.24"
1.26" .75" 2.76"
4.76"
.0006"
ø.563" .0011"
Dia. 16mm/.63"
M9.5 x 0.5
ø.87"
ø.83"
ø.315"
Specifications
Micrometer Heads
Inch
Order No. Range Resolution Accuracy Remarks
151-237 0–1" .0001" ±.0001" with Clamp Nut
151-238 0–1" .0001" ±.0001"
151-239 0–1" .001" ±.0001" with Clamp Nut
151-240 0–1" .001" ±.0001"
151-402 0–1" .001" ±.0001"
151-404 0–1" .001" ±.0002" with Spindle Lock
Metric
Order No. Range Resolution Accuracy Remarks
151-221 0–25mm 0.001mm ±0.002mm with Clamp Nut
151-222 0–25mm 0.001mm ±0.002mm
151-223 0–25mm 0.01mm ±0.002mm with Clamp Nut
151-224 0–25mm 0.01mm ±0.002mm
151-401 0–25mm 0.01mm ±0.002mm
151-403 0–25mm 0.01mm ±0.002mm with Spindle Lock
M-13
M-14 (2003) full size 12/8/03 4:32 PM Page 1
MICROMETER HEADS
Micrometer Heads
Series 151
151-411, 151-412
ø.500" .0007"
.0
151-271
ø.83"
ø.315"
2.44" .75" 4.06"
7.05"
ø.500" .0007"
Clamp Nut provided with
.0
this Micrometer Head.
ø.87"
ø.83"
ø.315"
( 12mm 0 )
-0.011"
.315"
10
5
45
40
2.32" 1.14"
7.52"
Features
• Carbide-tipped measuring face.
Specifications
Micrometer Heads
Inch
Order No. Range Resolution Accuracy Remarks
151-271 0–2" .001" ±.0002" with Clamp Nut
151-272 0–2" .001" ±.0002"
151-412 0–2" .001" ±.0002"
151-414 0–2" .001" ±.0002" with Spindle Lock
Metric
Order No. Range Resolution Accuracy Remarks
151-255 0–50mm 0.01mm ±0.004mm
151-256 0–50mm 0.01mm ±0.004mm
151-411 0–50mm 0.01mm ±0.004mm
151-413 0–50mm 0.01mm ±0.004mm with Spindle Lock
All 151 Series Micrometer Heads are supplied with carbide measuring face and ratchet stop.
M-14
M-15 (2003) full size 12/8/03 4:36 PM Page 1
MICROMETER HEADS
1.93"
.315"
0 70
.709" -0004"
R
3" .551" 60
.39 .236"
.098" .264"
152-401 2.19" (max) .650" 1.63"
5.27"
Micrometer Heads
Series 152
152-372 152-391
)
-0.018mm
.709" -.0004"
-.0007"
0
0
.433"
.250"
.315"
(12mm
.500"
.315"
1.93"
1.93"
.059"
.394"
1"MODEL-2.48" 1.14" Through hole .27"
2"MODEL-3.46" 1"MODEL-5.08" for spindle .55"
1.52"
2"MODEL-7.36" Lock .216" DIA 4.68"
Features
• Carbide-tipped measuring face. • Non-rotating device is attached to the spindle tip.
• Floating thimble can be rotated with the spindle fixed, (See “Technical Information” of this section.)
allowing zero setting at any position. • Bidirectional graduation.
Specifications
Micrometer Heads Inch
Inch Order No. Range Resolution Accuracy Remarks
Order No. Range Resolution Accuracy Remarks 152-391 0–1" .0001" ±.0001" For Y axis
152-372 0–1" .0001" ±.0001" 152-392 0–1" .0001" ±.0001" For X axis
152-388 0–2" .0001" ±.0002"
Metric
Metric Order No. Range Resolution Accuracy Remarks
Order No. Range Resolution Accuracy Remarks 152-389 0–25mm 0.005mm ±0.002mm For Y axis
152-348 0–25mm 0.002mm ±0.002mm 152-390 0–25mm 0.005mm ±0.002mm For X axis
M-15
M-16 (2003) full size 12/8/03 4:37 PM Page 1
MICROMETER HEADS
153-205 0 153-208
.500" -0007"
Non-Rotating
0
Spindle (12mm -0.011 )
Features 5 NOTE:( ) METRIC MODEL
.315"
• Carbide-tipped measuring face 0
45
• .001"(0.01mm) reading type and
.394"
.0001"(0.001mm) reading type OVERALL LENGTH
1.46"
with vernier. With Ratchet - 4.90"
No Ratchet - 4.23"
Specifications
Non-Rotating Spindle Micrometer Heads
Inch
Order No. Range Resolution Accuracy Remarks
153-207 0–1" .001" ±.00015"
153-205 0–1" .001" ±.00015" with Ratchet stop
153-208 0–1" .0001" ±.00015"
153-206 0–1" .0001" ±.00015" with Ratchet stop
Metric
Order No. Range Resolution Accuracy Remarks
153-203 0–25mm 0.01mm ±0.003mm
153-201 0–25mm 0.01mm ±0.003mm with Ratchet stop
153-204 0–25mm 0.001mm ±0.003mm
153-202 0–25mm 0.001mm ±0.003mm with Ratchet stop
Micrometer Heads
Series 197
.709"(DIA)
.315"(DIA)
10 80
1.93"
0 0
90 18
197-201 .55"
2.56"
5.63"
Features
• Carbide-tipped measuring face
• Non-rotating spindle
Micrometer Heads
Inch
Order No. Range Resolution Accuracy
197-201 0–2" .0002" ±.0002"
Metric
Order No. Range Resolution Accuracy
197-101 0–50mm 0.005mm ±0.005mm
M-16
M-17 (2003) full size 12/8/03 4:38 PM Page 1
MICROMETER HEADS
250-312
ø.375" -.0012"
0
"
54
ø.25"
.3
R
ø.71"
0
1.18"
45
Features
.67" 1.06" .59" .98"
• Spindle locking clamp .94" .05" 5.32"
• Carbide-tipped measuring face
• Ratchet stop for constant force.
Specifications
Digit Micrometer Heads with Mechanical Counter Outside Thimble
Inch
Order No. Range Resolution Accuracy Remarks
250-312 0–1" .0001" ±.0001" with Spindle Lock
Metric
Order No. Range Resolution Accuracy Remarks
250-301 0–25mm 0.01mm ±0.002mm with Spindle Lock
Micro Jack
Series 7
7850
Features
• Used for accurate leveling of machines,
surface plates, and other precision
instruments.
• Easy adjustment under heavy load.
Specifications
Metric
Height adjustment Order No. Graduation Maximum load
60 - 75mm 7850 0.01mm 400kgf
M-17
M-18 (2003) full size 12/8/03 4:39 PM Page 1
MICROMETER HEADS
B
B M
K
A
A
2-L
F
J
D
D
C
G
2-1
H G
H E
C E I
M-18
M-19 (2003) full size 12/8/03 4:40 PM Page 1
MICROMETER HEADS
Micrometer head
• Standard Accessories
Fixing screw for stem without clamp nut Micrometer head fixture
(Socket head screw: M3X0.5X12mm) Option
F
A
D .138"(3.5mm) .217"(5.5mm) .217"(5.5mm)
E 1.181"(30mm) 1.575"(40mm) 1.575"(40mm)
D 2-G
F .591"(15mm) .787"(20mm) .787"(20mm)
G ø.134"(3.4mm) ø.177"(4.5mm) ø.177"(4.5mm)
J
E .945"(24mm) 1.378"(35mm) 1.378"(35mm)
D
F .197"(5mm) .276"(7mm) .276"(7mm)
F
2-K
F .335"(8.5mm) .335"(8.5mm) .335"(8.5mm)
D
J
M-19
M-20 (2003) full size 12/8/03 4:26 PM Page 1
MICROMETER HEADS
H
A
D
F .118"(3mm) .197"(5mm) .197"(5mm)
J 2-I
G 1.181"(30mm) 1.575"(40mm) 1.575"(40mm) F
A
E .157"(4mm) .236"(6mm) .236"(6mm) F
D
2-L
G .295"(7.5mm) .394"(10mm) .394"(10mm)
D
J
M-20
N-01 (2003) full size 12/11/03 3:47 PM Page 1
INSIDE MICROMETERS
Inside Micrometers
Series 345, 145
LUT
SO E
AB
Y
OG
EC
H N OL
T
345-711-30
145-187
300401 Cap
145-193
300400 Holder
145-193
A special holder is available for inside microme-
ters.The holder must be used with No.156-101
MITUTOYO Stand or any other similar stand or
vise available in the shop.
Features
• Accuracy to .0002" with graduations of .001". • Every thousandth is numbered for easy reading.
• Easy zero adjustment. • Easily adjusted for slide movement of jaw (Exclusive.)
• Clear graduations on satin-chrome finish. • Spanner wrench is supplied with every micrometer.
• Caliper type jaws are made of high-grade, tool steel. • Complete with fitted carrying case.
They are satin-chrome finished. • Digimatic type features LCD Readout, Preset,
• Locking clamp for positive locking of spindle. Zero/ABS, Data/Hold, Inch/mm and SPC Output.
• With ratchet thimble for constant force.
Specifications
Digimatic Inside Micrometers with Absolute Encoder
Inch/Metric
LCD
Order No. Range Resolution Accuracy Remarks
345-711-30 .2"–1.18" .00005" ±.0002" with SPC output
5–30mm 0.001mm
345-712-30 1.0"–2.0" .00005" ±.00025" with SPC output
25.4-50.8mm 0.001mm
Metric
Order No. Range Resolution Accuracy Remarks
345-511-30 5–30mm 0.001mm ±0.005mm with SPC output
345-512-30 25–50mm 0.001mm ±0.006mm with SPC output
Note: Metric only Digimatic models have mm thimble and no inch/mm conversion function.
For SPC output order Connecting Cable 937387 (1m) or 965013 (2m). Replacement Battery: 541980 (1pc), 541980-10 (10pcs/SET).
N-2
N-03 (2003) full size 12/8/03 7:20 PM Page 1
INSIDE MICROMETERS
Inside Micrometers
Inch
Order No. Range Resolution Accuracy Remarks
145-193 .2"–1.18" .001" ±.0002" Measuring Face: A
145-194 1.0"–2.0" .001" ±.00025" Measuring Face: B
145-195 2.0"–3.0" .001" ±.0003" Measuring Face: C
145-196 3.0"–4.0" .001" ±.00035" Measuring Face: C
Metric
Order No. Range Resolution Accuracy Remarks
145-185 5–30mm 0.01mm ±0.005mm Measuring Face: A
145-186 25–50mm 0.01mm ±0.006mm Measuring Face: B
145-187 50–75mm 0.01mm ±0.007mm Measuring Face: C
145-188 75–100mm 0.01mm ±0.008mm Measuring Face: C
Measuring Face: A
.2"
R .087"
ø.079"
ø.079"
.18"
R .087"
1.08"
R.47"
.17"
1.24"
1.08"
1.08"
.49"
.49"
(1.0" to 2.0")
.177"
(.2" to 1.18")
.177"
Carbide Inlaid
.079" .079" (Diameter) (R=.48")
(R=.087") .48"
Carbide Pins
.69"
.118" .315"
.118"
.12"
.315"
1.26"
.1.3"
.079"
N-3
N-04 (2003) full size 12/8/03 7:22 PM Page 1
INSIDE MICROMETERS
Inside Micrometers
Series 141 – Interchangeable Type
141-233 141-102
141-101
The 141 Series Inside Micrometers are probably the most To provide point contact, all contact points are made
frequently used inside measuring instruments because of spherical and hardened for extra long tool life. The overall
their wide range and simplicity in measuring operation. accuracy is .0004" up to 12" (300mm), .001" thereafter to
No. 141-233, (photo shown), consists of 5 interchangeable 40".
rods, .500" micrometer head, .500" collar 1" extension
and handle. The range covered by this unit is 2" to 12".
Features
• Each interchangeable rod is marked with its measuring is used without the rod or collar.
range. For 1.250" to 1.500" a .250" collar is added between the
• Both micrometer head and furnished rods are satin- rod and head. For 1.500" to 1.750" range, the rod is
chrome finished throughout. replaced. For 1.750" to 2", the collar is added between
• Positive locking clamp attached on No. 141-101 and the rod and head. Thus, it measures 1" to 2"–.250" at a
141-102. No lock on the larger sizes. time.
• Supplied with fitted carrying case. No. 141-233
Since this Inside Micrometer comes with a .500" range
For closer tolerance work it is recommended that the Micrometer Head, the combining of rod, collar and
micrometer with a rod inserted be calibrated with a extended thimble is made simpler. For instance: the rod
known size such as a ring gage. The setting ring for marked 4–6" measures from 4"–4.5". For 4.5–5" range,
“Holtest” would be an ideal choice. the .500 collar is added. For 5"–5.5" the extension thim-
No. 141-102 ble is used and for 5.5" to 6" the extension thimble and
As shown here, the Micrometer Head has a 0–.250" collar are used.
range, reading in thousandths. A detachable holder pro- Both measuring ends are hardened and have micro-
vides easy access when measuring inside diameters lapped finish for lasting accuracy.
within deep holes. For 1" to 1.250" range, the micrometer
N-4
N-05 (2003) full size 12/8/03 7:24 PM Page 1
INSIDE MICROMETERS
Specifications
Inside Micrometers—Interchangeable Rod Type
Inch
Spacing Diameter
Order No. Range Collar of Rods Remarks
141-102 1–2" .250" .248" Includes 141-002 and 2 pcs rods
141-208 2–8" .500" .248" Includes 141-026, 3 rods and 1" extended thimble
141-233 2–12" .500" .248" Includes 141-026, 5 rods and 1" extended thimble
141-121 8–20" 1", 2" .355" Includes 141-010 and 3 pcs rods
141-122 8–40" 1", 2" .355" Includes 141-010 and 8 pcs rods
Metric
Spacing Diameter
Order No. Range Collar of Rods Remarks
141-101 25–50mm 6.0mm 6.3mm Includes 141-001 and 2 pcs rods
141-205 50–200mm 12.0mm 6.3mm Includes 141-025, 3 rods and 25mm extended thimble
141-206 50–300mm 12.0mm 6.3mm Includes 141-025, 5 rods and 25mm extended thimble
141-117 200–500mm 25mm, 50mm 9.0mm Includes 141-009 and 3 pcs rods
141-118 200–1000mm 25mm, 50mm 9.0mm Includes 141-009 and 8 pcs rods
Micrometer Heads
Inch
Order No. Head Travel Resolution Accuracy
141-002 .25" .001" ±.0001"
141-026 .50" .001" ±.0001"
141-010 1.00" .001" ±.0001"
Metric
Order No. Head Travel Resolution Accuracy
141-001 7.0mm 0.01mm ±0.003mm
141-025 13.0mm 0.01mm ±0.003mm
141-009 25.0mm 0.01mm ±0.003mm
1.71" (43.5)
.54" .91" .2"
(13.7) (23) (5)
.05" .07"
(1.2) (1.8)
(8.8) (11.5)
.45"
(ø6.5)
(ø15)
(ø15)
ø.26"
ø.59"
(ø12)
ø.47"
ø.2"
.35"
SR .39"
ø.16" (ø4) hole .24"
(6.2)
(SR10) 141-026
(METRIC)
141-001
N-5
N-06 (2003) full size 12/8/03 7:26 PM Page 1
INSIDE MICROMETERS
337-203
137-102
Features
• Wide range of ID measurements by combining • Power Supply:
extension rods with the micrometer head. The rod One Silver oxide cell (SR-44), offers 4,500 hours of life
is accurately finished and incorporated in a pipe for • The display automatically turns off if idle after 20 minutes.
shop-floor use.
• The 337 series provides digital readout to Accuracy
.0001"/0.001mm and can be linked to the SPC System. • Series 137, 337:
• Digimatic Function Include: [±(.00015+.00005n+.00005 (L/2))"]*/±(3+n+L/50)µm
Preset *n=Number of rods, L=Maximum measuring length [(inch)] (mm),
Inch/mm conversion Fraction rounded up
Zero-Set/ABS
Hold
Data Output
Specifications
Digimatic Inside Micrometers
Inch/Metric
LCD Head Extension Rods
Order No. Range Resolution Travel (Dia .50") Remarks
337-203 8–40" .0001"/0.001mm 1.0" 1", 2", 4" (2 pcs.) Includes Micrometer
8", 12" Head with SPC output.
337-204 8–60" .0001"/0.001mm 1.0" 1", 2", 4", 8" Includes Micrometer
12" (3 pcs.) Head with SPC output
For SPC output order Connecting Cable 937387 (1m) or 965013 (2m).
Replacement Battery: 541980 (1 pc.), 541980-10 (10 pcs. SET)
N-6
N-07 (2003) full size 12/8/03 7:28 PM Page 1
INSIDE MICROMETERS
Inside Micrometers
Inch
Extension Rods
Order No. Range (Diameter .50") Remarks
137-112 2–12" .5", 1", 2"(2pcs), 4" Include 137-002
137-114 2–40" .5", 1", 2", 4"(2pcs), 6", 8", 12" Include 137-002
Metric
Extension Rods
Order No. Range (Diameter 12.5mm) Remarks
137-102 50–300mm 13, 25, 50(2pcs), 100mm Include 137-001
137-104 50–1000mm 13, 25, 50, 100(2pcs), 150, 200, 300mm Include 137-001
137-108 50–500mm 13, 25, 50(2pcs), 100, 200mm Include 137-001
Rods with Carbide-tipped Measuring Face
Micrometer Heads
Inch
Order No. Head Travel Resolution Accuracy
137-002 .50" .001" ±.0001"
Metric
Order No. Head Travel Resolution Accuracy
137-001 13.0mm 0.01mm ±0.003mm
137-002
N-7
N-08 (2003) full size 12/8/03 7:30 PM Page 1
INSIDE MICROMETERS
339-293 139-179
Features Accuracy
• Wide range of ID measurements by combining exten- • Series 139, 339:
sion pipes and anvils with the micrometer head. [±(.00015+.00005n+.00005 (L/2))"]/±(3+n+L/50)µm*
• The 339 series provides digital readout to • Series 140:
.0001"/0.001mm and can be linked to the SPC System. [±.(0003+.00005n+.00005 (L/2))"]/±(7+n+L/50)µm*
*n=Number of rods, L=Maximum measuring length [(inch)] (mm),
• Pipe diameter Fraction rounded up
139 series: .67"/17mm
140 series: 1.26"/32mm
• For higher repeatability of measurement, light weight
extension pipes made of CFRP (Carbon Fiber
Reinforced Plastic) for 139 Series.
• Digimatic Functions Include:
Preset
Inch/mm conversion
Zero set/ABS
Hold
Data output
• Power Supply: One silver oxide cell
(SR-44) offers 4,500 hours of life
• The display automatically turns off idle after 20 minutes
Specifications
Tubular Inside Micrometers
Inch
Diameter Extension
Order No. Range of Rods Rods Remarks
139-201 1.5–12" .375" .5", 1", 2", 2.5", 3", 3.5", 4", 6" Include 139-004
139-202 4–40" .375" 1", 2", 3", 6", 9", 12", 14", 16", 17", 18" Include 139-006
Specifications
Digimatic Inside Micrometers (Series 339)
Inch/Metric
LCD Head Diameter
Order No. Range Resolution Travel of Rods Remarks
339-293 8–40" .0001" 1.0" .67" Include Micrometer Head and 5 pcs rods
0.001mm with SPC output
339-294 8–80" .0001" 1.0" .67" Include Micrometer Head and 8 pcs rods
0.001mm with SPC output
For SPC output order Connecting Cable 937387 (1m) or 965013 (2m).
Replacement Battery: 541980 (1 pc.), 541980-10 (10 pcs./SET)
N-8
N-09 (2003) full size 12/8/03 7:31 PM Page 1
INSIDE MICROMETERS
139-002 139-004
1 3
Ø4
Ø4
Ø18
Ø4
Ø4
Ø33 Ø33
Ø8 Ø8
Ø32
Ø21
Ø19
SR10 SR10
16.5 175.5 699 101 15
1000 to 1050
N-9
N-10 (2003) full size 12/8/03 7:14 PM Page 1
INSIDE MICROMETERS
133-223 133-224
133-225
133-226
Features
• Accuracy up to 4" ±.00015" • 2–6" set and 2–12" set are available.
4–6" ±.0002" • Clear, crisp graduations on the satin chrome finished
6–12" ±.0003" micrometer head.
• With positive locking clamp. • Carbide tipped measuring faces.
• Zero point can be readjusted by twisting the micrometer • Supplied in a carrying case.
head sleeve. A key wrench is supplied.
Specifications
Tubular Inside Micrometers Tubular Inside Micrometers
Inch Metric
Order No. Range Resolution Accuracy Order No. Range Resolution Accuracy
133-223 2–3" .001" ±.00015" 133-143 50-75mm 0.01mm ±3 µm
133-224 3–4" .001" ±.0002" 133-144 75-100mm 0.01mm ±4 µm
133-225 4–5" .001" ±.00025" 133-145 100-125mm 0.01mm ±5 µm
133-226 5–6" .001" ±.00025" 133-146 125-150mm 0.01mm ±5 µm
133-227 6–7" .001" ±.00025" 133-147 150-175mm 0.01mm ±5 µm
133-228 7–8" .001" ±.00025" 133-148 175-200mm 0.01mm ±5 µm
133-229 8–9" .001" ±.00025" 133-149 200-225mm 0.01mm ±5 µm
133-230 9–10" .001" ±.0003" 133-150 225-250mm 0.01mm ±6 µm
133-231 10–11" .001" ±.0003" 133-151 250-275mm 0.01mm ±6 µm
133-232 11–12" .001" ±.0003" 133-152 275-300mm 0.01mm ±6 µm
Tubular Inside Micrometer Sets Tubular Inside Micrometer Sets
Inch Metric
Order No. Total Range Set Configuration Order No. Total Range Set Configuration
133-903 2–6" 133-223, 224, 225, 226 133-901 50-150mm 133-143, 144, 145, 146
(4 Mikes/set) with fitted case (4 Mikes/set) with fitted case
133-904 2–12" 133-223, 224, 225, 226, 133-902 50-300mm 133-143, 144, 145, 146,
(10 Mikes/set) 227, 228, 229, 230, 231, 232 (10 Mikes/set) 147, 148, 149, 150, 151, 152
with fitted case with fitted case
N-10
N-11 (2003) full size 12/8/03 7:17 PM Page 1
INSIDE MICROMETERS
DIMENSIONS (inch) L
Order No. L A B
133-225 4" .15" .12" A 1.85" B
133-226 5" .14" .12" (47)
ø.315"
ø.315"
133-227 6" .65" .59"
(ø8)
(ø8)
133-228 7" .61" .59"
.71" (ø18)
133-229 8" .61" .59"
133-230 9" .61" .59"
133-231 10" .61" .59"
133-232 11" .61" .59"
R=.394" R=.394"
(SR10) (SR10)
1.97"
(50)
.14" .12"
(3.5) (3)
1.45"
ø.315"
ø.315"
(37)
(ø8)
(ø8)
ø.59"
133-143
R=.394" 133-223 R=.394"
(SR10) (SR10)
DIMENSIONS (metric)
ø.315"
ø.315"
(ø8)
(ø8)
Order No. L A B
133-145 100 3.8 3
133-146 125 3.5 3
ø.59"
133-144
133-224
(mm)
N-11
N-12 (2003) full size 12/9/03 9:52 AM Page 1
BORE GAGES
Features
• .00012” (0.003mm) or less wide range accuracy
• Anvil displacement is directly detected by the ultra
compac built-in sensor (no mechanical transmitter is used)
• Maximum extension up to 78.74” (2000mm)
• Reaches deep holes easily!
• Simple to operate – can preset 3 reference (master) value
and set upper/lower tolerance limits for each!
• IP53 dust/water protection level
Specifications
Order No. 511-521
Range 1.8" - 4" (45 - 100mm)
Contact Point Stroke .048" / 1.2mm
Resolution .00005" / 0.001mm
Wide range accuracy .00012" / 0.003mm
Narrow range accuracy .00008" / 0.002mm
Repeatability ±1 count
Quantizing error ±1 count
Measuring force 5N or less
Battery (541980) Silver oxide cell (SR-44–2 pcs.)
Battery Life 9 months under normal use
Sensor/scale Electrostatic capacitance
absolute scale
Sampling frequency 50 times / sec
Protection level IP53
Data output SPC data output
Mass 1.1 lbs. / 500g
Standard Accessories
Anvils 14 pcs.
Spacer 4 pcs. .02", .04", .08", .12"
Hex Wrench 1 pc. Specifications
Optional Accessories Order No. 516-120-22
905338 SPC Cable 40"/1m Set of:
905409 SPC Cable 80"/2m Steel Rectangular gage Block
21DZA089 Extension Rod 9.84"/250mm .04", .08", .16", .2", .4", .8", 1", 2", 3"
21DZA081 Extension Rod 19.69"/500mm Flat Jaw (619970) 2 pcs.
516-120-22 Measuring Size set Holder 160mm (619004) 1 pc.
Gage Block Set Wooden Box
N-12
N-13 (2003) full size 12/8/03 7:21 PM Page 1
BORE GAGES
1.157"
rotation RESET sw 29.4
(320°)
M/W sw
inclination (90°)
"
ø2.402
ø61 For inch-readable model
ON/OFF in/mm sw
DATA/HOLD sw TOL sw
PRESET sw ø1.102" M26x1.5
START sw ø28
5.906"
150
16.5
.65"
3.937"
100
rotation
(320°)
9.843" ( 19.685")
10.571" (20.413")
9.134" (18.976")
(13.366")
268.5 (518.5)
(339.5)
250 (500)
232 (482)
ø 1.181" ø.866"
ø 30 ø22
.787"
20
5.906"
1.102"
150
1.181"
30 28
.059"
1.5
ø1.102"
28
2
SR 79"
.354"
. 0
9
R 1.339"
34
N-13
N-14 (2003) full size 12/8/03 7:23 PM Page 1
BORE GAGES
526-173
Optional Stand
526-120 (215-120M)
Probe Depth (L)
Features
• Measures diameters of small holes. • Accuracy: .00016"/4µm (Range: .037–.4"/0.95–10mm)
• Radius displacement of split-ball contact is converted to .00024"/6µm (Range: .4–.7"/10–18mm)
axial displacement of measuring pin, which is shown on • Optional stand (215-120) for Bore Gages Series 526
the dial indicator. is available for efficient measurement of multiple
• Digimatic Indicator can be installed in place of the dial small holes.
indicator.
Specifications
Dial Bore Gages
Inch
Order No.* Order No. Order No. Measuring Number of Probe
Without Dial With 2922FB With 2923FB-10 Range Anvils Depth
Gage Graduation .0005" Graduation .0001"
526-103 526-119 526-122 .3"-.4" 6 pcs. 2.2"
526-104 526-120 526-123 .4"-.7" 8 pcs. 2.4"
*Does not include dial gage cover.
Metric
Order No.* Order No. Order No. Measuring Number of Probe
Without Dial With 2046FB With 2109FB Range Anvils Depth
Gage Graduation 0.01mm Graduation .0.001mm
526-101 526-126 526-124 7-10mm 6 pcs. 56mm
526-102 526-127 526-125 10-18mm 8 pcs. 62mm
*Does not include dial gage cover.
N-14
N-15 (2003) full size 12/8/03 7:25 PM Page 1
BORE GAGES
Specifications
Dial Bore Gages
Split-Ball Type
Inch
Order No.* Order No. with Measuring Anvil Setting Ring No. of
Without 2923FB-10 Range Probe Range Length Code No. Size Needle
Dial Gage Graduation .0001" No.
1.0 .037"–.045" 177-220 .04"
1.1 .042"–.049" 177-222 .045"
526-175 526-176 .037"–.061" 1.2 .046"–.053" .45" 177-225 .05" 1
1.3 .050"–.057" 177-227 .055"
1.4 .054"–.061" 177-230 .06"
1.75 .060"–.075" 177-236 .07"
2.00 .070"–.085" .69" 177-239 .08"
2.25 .080"–.095" 177-242 .09"
2.50 .090"–.105" 177-208 .10"
526-165 526-166 .060"–.157" 2.75 .100"–.115" 177-246 .11" 2
3.00 .110"–.125" 177-248 .12"
.89"
3.25 .120"–.135" 177-250 .13"
3.50 .130"–.145" 177-252 .14"
3.75 .140"–.157" 177-255 .15"
4.0 .145"–.170" 177-204 .16"
4.5 .165"–.190" 177-257 .18"
5.0 .185"–.210" 177-205 .20"
526-155 526-156 .145"–.290" 5.5 .205"–.230" 1.26" 177-263 .22" 1
6.0 .225"–.250" 177-267 .24"
6.5 .245"–.270" 177-271 .26"
7.0 .265"–.290" 177-275 .28"
Metric
Order No.* Order No. with Order No. with Measuring Anvil Setting Ring No. of
Without 2046FB 2109FB Range Probe Range Length Code Size Needle
Dial Gage Graduation Graduation No. (mm) No. (mm)
0.01mm 0.001mm
1.0 0.95–1.15mm 177-220 1.0
1.1 1.07–1.25mm 177-222 1.1
526-170 526-173 526-172 0.95–1.55mm 1.2 1.17–1.35mm 11.5 177-225 1.2 1
1.3 1.27–1.45mm 177-227 1.3
1.4 1.37–1.55mm 177-230 1.4
1.75 1.50–1.90mm 177-236 1.75
2.00 1.80–2.20mm 17.5 177-239 2.00
2.25 2.05–2.45mm 177-242 2.25
2.50 2.25–2.75mm 177-208 2.50
526-160 526-163 526-162 1.5–4mm 2.75 2.50–3.00mm 177-246 2.75 2
3.00 2.75–3.25mm 22.5 177-248 3.00
3.25 3.00–3.50mm 177-250 3.25
3.50 3.25–3.75mm 177-252 3.50
3.75 3.50–4.00mm 177-255 3.75
4.0 3.7–4.3mm 177-204 4.0
4.5 4.2–4.8mm 177-257 4.5
5.0 4.7–5.3mm 177-205 5.0
526-150 526-153 526-152 3.7–7.3mm 5.5 5.2–5.8mm 32 177-263 5.5 1
6.0 5.7–6.3mm 177-267 6.0
6.5 6.2–6.8mm 177-271 6.5
7.0 6.7–7.3mm 177-275 7.0
Above sets include setting rings.
*Does not include Dial gage cover.
N-15
N-16 (2003) full size 12/8/03 7:27 PM Page 1
BORE GAGES
511-162
511-212
.24–.4" .4"–.74"
10–18.5mm
.7"–2.4" 2.0"–16.0"
18–60mm 50–400mm
Features
• Interchangable anvils and necessary accessories to • Optional extension rods can be attached.
perform close tolerance I.D. measurements. • A Digimatic Indicator can be attached in place of the
• Carbide ball contact point for durability. dial gage.
• Accuracy: .0002"/5µm
Dial Faces
+ 0 _
_0+
+ 0 _ 1
10 1
0 10 0
5 5 1 1 2
20 2
20 90 10
3
30 3
30
.0001" 1µm
1µm
10
.0005"
10 2 2 4
40 4
40 80
0.01"
20
5
50 NO.1011-11
5
50
NO. 2922-08 ® 2 3 ® NO. 2109FB ® Shock
15 2 3
SHOCK
MADE IN
PROOF
JAPAN
15 3 0
1 4
5
6 JEWELS
3 6
60 .8
10 0
.6 .4
.2
1.0
6J E W E ELLES D
JEW
MADE IN JAPAN
6
60 70 2
1
0 9
8
30
1 0
.2 .8 3 7
0
707
.4 .6
7
70 4 5
6
20 20 808 8 60 40
4 4 80
25 5 10 909
909 100 50
N-16
N-17 (2003) full size 12/8/03 7:29 PM Page 1
BORE GAGES
Specifications
Dial Bore Gages
Inch
Order No.* Order No. Order No. Measuring Number Number Probe
Without With 2922FB With 2923FB-10 Range of Anvils of Spacers Depth
Dial Gage Graduation .0005" Graduation .0001"
511-214 511-213 511-212 .24"-.4" 9 pcs. - 2"
511-205 511-207 511-206 .4"-.74" 9 pcs. 1 4"
511-104 511-159 511-163 .7"-1.4" 8 pcs. 3 4"
511-105 511-160 511-164 1.4"-2.5" 6 pcs. 4 6"
511-107 511-162 511-166 2"-6" 11 pcs. 4 6"
2" Sub-Anvil
511-181 511-184 511-187 4"-6.5" 13 pcs. 4 6"
511-182 511-185 511-188 6.5"-10.0" 6 pcs. 6 10"
511-183 511-186 511-189 10.0"-16.0" 5 pcs. 6 10"
511-911 (set) 511-912 (set) .7"-6.0" 25 pcs. 7 4", 6"
2" Sub-anvil
*Does not include dial gage cover.
Metric
Order No.* Order No. Order No. Measuring Number Number Probe
Without With 2046FB With 2109FB Range of Anvils of Spacers Depth
Dial Gage Graduation 0.01mm Graduation 0.001mm
511-201 511-204 511-203 10-18.5mm 9 pcs. 1 90mm
511-126 511-171 511-167 18-35mm 9 pcs. 2 100mm
511-127 511-172 511-168 35-60mm 6 pcs. 4 150mm
511-128 511-173 511-169 50-100mm 11 pcs. 4 150mm
511-132 511-174 511-170 50-150mm 11 pcs. 4 150mm
50 mm Sub-anvil
511-129 511-175 511-178 100-160mm 13 pcs. 4 150mm
511-130 511-176 511-179 160-250mm 6 pcs. 7 250mm
511-131 511-177 511-180 250-400mm 5 pcs. 7 250mm
511-901 (set) 511-902 (set) 18-150mm 26 pcs. 7 100mm
50mm Sub-anvil 150mm
*Does not include dial gage cover.
Optional Accessories
Extension Rods
Bore Gage Extension Length
Measuring 4.92" 9.84" 19.69" 29.53" 39.37" Rod Spanner
Range 125mm 250mm 500mm 750mm 1000mm Diameter
.7–1.4" 953549 953550 953551 –– –– .34" 102148A
18–35mm 8.7mm
1.4–6.5" 953552 953553 953554 953555 953556 .47" 212556
35–160mm 12mm
6.5–16" 953557 952361 953558 953559 953560 .59" 212556
160–400mm 15mm
Note: Above list is used for 511-1XX series; not available for 511-2XX Series.
N-17
N-18 (2003) full size 12/8/03 7:31 PM Page 1
BORE GAGES
511-319
Extension Rod
Features
• Interchangeable anvil is attached to a micrometer head • Optional extension rods can be attached.
for accurate dimensional setting. • A Digimatic Indicator can be attached in place of the
• Carbide ball contact point for durability. dial gage.
• Measuring range can be expanded by attaching a • Accuracy: .0002"/5µm
sub-anvil.
N-18
N-19 (2003) full size 12/8/03 7:32 PM Page 1
BORE GAGES
Specifications
Dial Bore Gages with Micrometer Heads
Inch
Order No.* Order No. Order No. Measuring Mike Head Extensions Probe
Without With 2922FB With 2923FB-10 Range Travel Mike Head Depth
Dial Gage Graduation .0005" Graduation .0001"
511-342 511-345 511-346 1.4-2.5" .2" .2", .4", .6", .8" 6"
511-332 511-335 511-336 2.4-4.0" .4" .4", .8" 6"
511-306 511-325 511-326 4.0-6.0" .5" .4", .8", .8" 6"
511-307 511-319 511-320 6.0-10.0" 1" 1", 2" 10"
511-308 511-321 511-322 10.0-16.0" 2" 2", 2" 10"
511-309 511-323 511-324 16.0-24.0" 2" 2", 4" 10"
511-310 511-329 511-330 24.0-32.0" 2" 2", 4" 10"
*Does not include dial gage cover.
Metric
Order No.* Order No. Order No. Measuring Mike Head Extensions Probe
Without With 2046FB With 2109FB Range Travel Mike Head Depth
Dial Gage Graduation 0.01mm Graduation 0.001mm
511-341 511-344 511-343 35-60mm 5mm 5mm, 10mm
15mm, 20mm 150mm
511-331 511-334 511-333 60-100mm 10mm 10mm, 20mm 150mm
511-301 511-312 511-311 100-160mm 13mm 10mm, 20mm,
20mm 150mm
511-302 511-314 511-313 150-250mm 25mm 25mm, 50mm 250mm
511-303 511-316 511-315 250-400m 50mm 50mm, 50mm 250mm
511-304 511-318 511-317 400-600mm 50mm 50mm, 100mm 250mm
511-305 511-328 511-327 600-800mm 50mm 50mm, 100mm 250mm
*Does not include dial gage cover.
Optional Accessories
Extension Rods
Bore Gage Extension Length
Measuring 4.92" 9.84" 19.69" 29.53" 39.37" Rod Spanner
Range 125mm 250mm 500mm 750mm 1000mm Diameter
1.4-2.5" 953549 953550 953551 –– –– .34" 102148A
35–60mm 8.7mm
2.4–6.4" 953552 953553 953554 953555 953556 .47" 212556
60–160mm 12mm
6.0–32.0" 953557 952361 953558 953559 953560 .59" 212556
150–800mm 15mm
Note: Above list is used for 511-3XX Series.
N-19
N-20 (2003) full size 12/8/03 7:16 PM Page 1
BORE GAGES
Features
• Can measure ID at position close to the bottom of
blind holes.
511-431 511-442 • A Digimatic Indicator can be attached in place of the
dial gage.
• Accuracy: .0002"/5µm
Probe Depth
6" (150mm)
Specifications
Dial Bore Gages
Inch
Order No.* Order No. Order No. Measuring Number of Number of
Without Dial With 2922FB With 2923FB-10 Range Anvils Spacers
Gage Graduation .0005" Graduation .0001"
511-406 511-431 511-441 .6-1.4" 11 pcs., .4" Sub-anvil 1
511-407 511-432 511-442 1.4-2.4" 6 pcs. 4
511-408 511-433 511-443 2.0-4.0" 11 pcs. 4
511-409 511-434 511-444 2.0-6.0" 11 pcs., 2" Sub-anvil 4
*Does not include dial gage cover.
Metric
Order No.* Order No. Order No. Measuring Number of Number of
Without Dial With 2046FB With 2109FB Range Anvils Spacers
Gage Graduation 0.01mm Graduation 0.001mm
511-401 511-411 511-421 15-35mm 11 pcs., 10mm Sub-anvil 1
511-402 511-412 511-422 35-60mm 6 pcs. 4
511-403 511-413 511-423 50-100mm 11 pcs. 4
511-404 511-414 511-424 50-150mm 11 pcs., 50mm Sub-anvil 4
*Does not include dial gage cover.
Extension rods are not available for 511-4XX Series.
N-20
N-21 (2003) full size 12/8/03 7:17 PM Page 1
HOLTESTS
Holtests
Series 368 – Two Point Models for Very Small Holes
368-022
368-023
368-024
368-025
Specifications
Holtests–Two Point Models
Inch
Individual Accessories
Set Order No. Range Order No. Grad. L1 L2 Included In Set
.080–.100" 368-021 .0001" .47" 4" 177-209 Setting Ring .100" Dia.
368-926
.100–.120" 368-022 .0001" .47" 4" 202863 Hex Wrench
.120–.160" 368-023 .0001" .86" 4.5" 177-206 Setting Ring .160" Dia.
.160–.200" 368-024 .0001" .86" 4.5" 177-207 Setting Ring .240" Dia.
368-927
.200–.240" 368-025 .0001" .86" 4.5" 202863 Hex Wrench
.240–.280" 368-026 .0001" .86" 4.5"
Metric
Individual Accessories
Set Order No. Range Order No. Grad. L1 L2 Included in Set
2–2.5mm 368-001 0.001mm 12mm 104mm 177-208 Setting Ring 2.5mm Dia.
368-906
2.5–3mm 368-002 0.001mm 12mm 104mm 202863 Hex Wrench
3–4mm 368-003 0.001mm 22mm 114mm 177-204 Setting Ring 4mm Dia.
368-907 4–5mm 368-004 0.001mm 22mm 114mm 177-205 Setting Ring 5mm Dia.
5–6mm 368-005 0.001mm 22mm 114mm 202863 Hex Wrench
N-21
N-22 (2003) full size 12/8/03 7:19 PM Page 1
HOLTESTS
Holtests
Series 368
368-201
368-103
Specifications
Holtest
Inch with Carbide
Set Individual Accessories
Order No. Range Order No. Graduation L1 L2 included in Set
177-179 Setting Ring .350" DIA.
.275–.350" 368-201 .0001" 2.32" 4.05"~4.13" 177-180 Setting Ring .500" DIA.
368-921 .350–.425" 368-202 .0001" 2.32" 4.05"~4.13" 952322 Extension Rod 4"
.425–.500" 368-203 .0001" 2.32" 4.05"~4.13" 205289 Spanners (pair)
202863 Hex Wrench
Metric with Carbide
Set Individual Accessories
Order No. Range Order No. Graduation L1 L2 included in Set
177-125 Setting Ring 8mm DIA.
6–8mm 368-101 0.001mm 59mm 103~105mm 177-126 Setting Ring 10mm DIA.
368-901 8–10mm 368-102 0.001mm 59mm 103~105mm 952322 Extension Rod 100mm
10–12mm 368-103 0.001mm 59mm 103~105mm 205289 Spanners (pair)
202863 Hex Wrench
N-22
N-23 (2003) full size 12/8/03 7:21 PM Page 1
HOLTESTS
Holtests
Series 368 – Interchangeable Anvil Type
368-206
368-238
Internal Construction
Holtest
a=.012" Standard Finish
0.3mm
Range .5-1.2"
12-30mm
Holtest
with Carbide
16
24
Specifications
Inch
Set Individual
Order No. Range Order No. Graduation L1 L2 Accessories included in Set
Hardened Alloy Tool Steel Anvil and Cone (Standard Finish) 177-182 Setting Ring, .650" DIA.
368-982 .500–.650" 368-804 .0002" 3.15" 4.88~5.04"
.650–.800" 368-805 .0002" 3.15" 4.88~5.04" 952621 Extension Rod, 5.9"
N-23
N-24 (2003) full size 12/8/03 7:23 PM Page 1
HOLTESTS
Holtests
Series 368
Specifications
Inch
Set Individual Accessories
Order No. Range Order No. Graduation L1 L2 included in Set
Hardened Alloy Tool Anvil and Cone (Standard Finish)
2.0–2.5" 368-840 .0002" 4.13" 5.94~6.46"
368-969 2.5–3.0" 368-841 .0002" 4.13" 5.94~6.46" 177-315 Setting Ring, 2.5" DIA.
3.0–3.5" 368-842 .0002" 4.13" 5.94~6.46"
177-319 Setting Ring, 3.5" DIA.
3.5–4.0" 368-843 .0002" 4.13" 5.94~6.46"
952623 Extension Rod, 5.9"
With Carbide
210189 Spanners (Pair)
2.0–2.5" 368-240 .0002" 4.13" 5.94~6.46"
368-959 2.5–3.0" 368-241 .0002" 4.13" 5.94~6.46" 202863 Hex. Wrench
3.0–3.5" 368-242 .0002" 4.13" 5.94~6.46"
3.5–4.0" 368-243 .0002" 4.13" 5.94~6.46"
Hardened Alloy Tool Steel Anvil and Cone (Standard Finish)
4–5" 368-817 .0002" 6.22" 8.78~9.76"
368-985 5–6" 368-818 .0002" 6.22" 8.78~9.76" 177-299 Setting Ring, 5" Dia.
6–7" 368-819 .0002" 6.22" 8.78~9.76" 177-303 Setting Ring, 7" Dia.
7–8" 368-820 .0002" 6.22" 8.78~9.76" 952623 Extension Rod, 5.9"
With Carbide 205348 Spanners (Pair)
4–5" 368-217 .0002" 6.22" 8.78~9.76" 202863 Hex. Wrench
368-925 5–6" 368-218 .0002" 6.22" 8.78~9.76"
6–7" 368-219 .0002" 6.22" 8.78~9.76"
7–8" 368-220 .0002" 6.22" 8.78~9.76"
Hardened Alloy Tool Steel Anvil and Cone (Standard Finish)
8–9" 368-821 .0002" 6.22" 8.78~9.76"
9–10" 368-822 .0002" 6.22" 8.78~9.76"
10–11" 368-823 .0002" 6.22" 8.78~9.76"
11–12" 368-824 .0002" 6.22" 8.78~9.76" Larger Holtests are sold
With Carbide individually. No set available.
8–9" 368-221 .0002" 6.22" 8.78~9.76"
9–10" 368-222 .0002" 6.22" 8.78~9.76"
10–11" 368-223 .0002" 6.22" 8.78~9.76"
11–12" 368-224 .0002" 6.22" 8.78~9.76"
NOTE: “Holtest” Sets are not available over 8" Range.
N-24
N-25 (2003) full size 12/8/03 7:25 PM Page 1
HOLTESTS
Holtests
Series 368
Specifications
Metric
Set Individual
Order No. Range Order No. Graduation L1 L2 Accessories included in Set
Hardened Alloy Tool Steel Anvil and Cone (Standard Finish)
368-972 12–16mm 368-704 0.005mm 80mm 124~128mm 177-177 Setting Ring, 16mm DIA.
16–20mm 368-705 0.005mm 80mm 124~128mm 952621 Extension Rod, 150mm
With Carbide 205312 Spanners (Pair)
368-902 12–16mm 368-104 0.005mm 80mm 124~128mm 202863 Hex. Wrench
16–20mm 368-105 0.005mm 80mm 124~128mm
Hardened Alloy Tool Steel Anvil and Cone (Standard Finish)
20–25mm 368-706 0.005mm 90mm 135~140mm
368-963 25–30mm 368-707 0.005mm 90mm 135~140mm
30–40mm 368-738 0.005mm 98mm 144~154mm 177-139 Setting Ring,
40–50mm 368-739 0.005mm 98mm 144~154mm 25mm DIA.
With Carbide 177-140 Setting Ring, 40mm DIA.
20–25mm 368-106 0.005mm 90mm 135~140mm 952622 Extension Rod, 150mm
368-953 25–30mm 368-107 0.005mm 90mm 135~140mm 210189 Spanners (Pair)
30–40mm 368-138 0.005mm 98mm 144~154mm 202863 Hex. Wrench
40–50mm 368-139 0.005mm 98mm 144~154mm
Hardened Alloy Tool Steel Anvil and Cone (Standard Finish)
50–63mm 368-740 0.005mm 105mm 151~164mm
368-964 62–75mm 368-741 0.005mm 105mm 151~164mm 177-314 Setting Ring, 62mm DIA.
75–88mm 368-742 0.005mm 105mm 151~164mm 177-318 Setting Ring, 87mm DIA.
87–100mm 368-743 0.005mm 105mm 151~164mm 952623 Extension Rod, 150mm
With Carbide 210189 Spanners (Pair)
50–63mm 368-140 0.005mm 105mm 151~164mm 202863 Hex. Wrench
368-954 62–75mm 368-141 0.005mm 105mm 151~164mm
75–88mm 368-142 0.005mm 105mm 151~164mm
87–100mm 368-143 0.005mm 105mm 151~164mm
Hardened Alloy Tool Steel Anvil and Cone (Standard Finish)
100–125mm 368-717 0.005mm 158mm 223~248mm
368-975 125–150mm 368-718 0.005mm 158mm 223~248mm 177-298 Setting Ring, 125mm Dia.
150–175mm 368-719 0.005mm 158mm 223~248mm 177-302 Setting Ring, 175mm Dia.
175–200mm 368-720 0.005mm 158mm 223~248mm
952623 Extension Rod, 150mm
With Carbide 205348 Spanners (Pair)
100–125mm 368-117 0.005mm 158mm 223~248mm
202863 Hex. Wrench
368-905 125–150mm 368-118 0.005mm 158mm 223~248mm
150–175mm 368-119 0.005mm 158mm 223~248mm
175–200mm 368-120 0.005mm 158mm 223~248mm
Hardened Alloy Tool Steel Anvil and Cone (Standard Finish)
200–225mm 368-721 0.005mm 158mm 223~248mm
225–250mm 368-722 0.005mm 158mm 223~248mm
250–275mm 368-723 0.005mm 158mm 223~248mm
275–300mm 368-724 0.005mm 158mm 223~248mm Larger Holtests are sold individually.
With Carbide No set available.
200–225mm 368-121 0.005mm 158mm 223~248mm
225–250mm 368-122 0.005mm 158mm 223~248mm
250–275mm 368-123 0.005mm 158mm 223~248mm
275–300mm 368-124 0.005mm 158mm 223~248mm
NOTE: “Holtest” Sets are not available over 200mm Range.
N-25
N-26 (2003) full size 12/8/03 7:27 PM Page 1
HOLTESTS
Digimatic Holtests
Series 468
468-234
Range A
Stand and mounting plate
.275–.5"/6–12mm .079"/2mm
.5"–4"/12-100mm .012"/0.3mm are optional
4–12"/100–300mm .512"/13mm
982693
N-26
N-27 (2003) full size 12/8/03 7:29 PM Page 1
HOLTESTS
Specifications
Digimatic Holtests Interchangeable-Head Sets
Inch/Metric
Range .275–.5"/6.985–12.7mm
Set Order No. 468-956 Thimble Graduation .0002"
Includes: LCD Readout
982332 Display & Thimble Unit Up to 4" .00005"/0.001mm
952909 Interchangeable Head Over 4" .0001"/0.001mm
.275–.35"/6.985–8.89mm
952910 Interchangeable Head
.35–.425"/8.89–10.795mm
952911 Interchangeable Head
.425–.5"/10.795–12.7mm
177-179 Setting Ring .350" DIA.
177-283 Setting Ring .425" DIA.
952322 Extension Rod 3.94" (100mm)
210187 Spanners (one pair) Range .8–2"/20.32–50.8mm
202863 Hex Wrench Set Order No. 468-958
541980 SR44 Battery Includes:
982334 Display & Thimble Unit
952672 Interchangeable Head
.8–1"/20.32–25.4mm
Range .5–.8"/12.7–20.32mm 952673 Interchangeable Head
Set Order No. 468-957 1–1.2"/25.4–30.48mm
Includes: 982149 Interchangeable Head
982333 Display & Thimble Unit 1.2–1.6"/30.48–40.64mm
952670 Interchangeable Head 982150 Interchangeable Head
.5–.65"/12.7–16.51mm 1.6–2.0"/40.64–50.8mm
952671 Interchangeable Head 177-184 Setting Ring 1.000" DIA.
.65–.8"/16.51–20.32mm 177-291 Setting Ring 1.600" DIA.
177-182 Setting Ring .650" DIA. 952622 Extension Rod 5.9" (150mm)
952621 Extension Rod 5.9" (150mm) 210189 Spanners (one pair)
210188 Spanners (one pair) 202863 Hex Wrench
202863 Hex Wrench 541980 SR44 Battery
541980 SR44 Battery
For SPC output order connecting cable 937387 (40"/1m) or 965013 (80"/2m).
N-27
N-28 (2003) full size 12/8/03 7:31 PM Page 1
HOLTESTS
Digimatic Holtest
Series 468
468-966
Complete Unit
Sets
N-28
N-29 (2003) full size 12/8/03 7:32 PM Page 1
HOLTESTS
Specifications
Digimatic Holtests Complete Unit Sets
Inch/Metric
Individual Graduation Digimatic Holtests Sets
Range Order No. Thimble LCD Readout (Complete Unit)
Set Order No. 468-968
1–1.2"/ 468-237 .0002" .00005"/0.001mm Includes:
25.4–30.48mm 468-237 Complete Gage
468-238 Complete Gage
1.2–1.6"/ 468-238 .0002" .00005"/0.001mm 468-239 Complete Gage
30.48–40.64mm 177-289 Setting Ring 1.2" DIA.
177-291 Setting Ring 1.6" DIA.
1.6–2"/ 468-239 .0002" .00005"/0.001mm 210189 Spanners
40.64–50.8mm 202863 Hex Wrench
541980 SR44 Batteries
For SPC output order connecting cable 937387 (40"/1m) or 965013 (80"/2mm)
Dimensions
Code No. L1 L2
468-231, 232, 233 1.77" 6.81"-6.89"
468-234, 235 2.99" 7.87"-8.03"
468-236, 237 3.46" 8.39"-8.58"
468-238, 239 4.02" 8.78"-9.17"
468-240, 241, 242, 243 4.13" 8.94"-9.45"
468-244, 245, 246, 247, 248
249, 250, 251 5.94" 11.5"-12.48"
N-29
N-30 (2003) full size 12/8/03 7:16 PM Page 1
BORE GAGES
901529
(A) 3.5"
Depth (A)
901531
(A)10.5"
901532
(A)12.5"
Optional
Extensions
901533
(A)15.5"
Features
Replacement Heads
• Carbide-tipped contact point for excellent durability.
2.64" 1.10"
• Easy zero adjustment because the Bore Gage can 1.65"
stand upright.
• Interchangeable anvils have a large radius of curvature
for repeatable ID measurements of roughly finished
holes. No. 901956 No. 901957
• Two guide pins ensure high repeatability of measure- No. 901955 Range: 2-3"
50-75mm
Range: 1.5-2"
35-50mm
Range: 3-6"
ments. 75-150mm
• Wide range of measurements with interchangeable
anvils (screw-in type).
• .0005"(0.01mm) or .0001"(0.001mm) reading types.
• Carbide tipped anvil (optional): 901484 Accuracy • .0002"/5mm
Specifications
Dial Bore Gages
Inch
Order No. (with Indicator) Probe Number of
.0005" .0001" Range Depth Anvil
545-124 545-134 1.5–2" 3.5" 5
545-125 545-135 2–3" 4.5" 5
545-126 545-136 3–6" 6" 7
Metric
Order No. (with Indicator) Probe Number of
0.01mm 0.001mm Range Depth Anvil
545-104 545-114 35–50mm 88mm 5
545-105 545-115 50–75mm 113mm 5
545-106 545-116 75–150mm 153mm 7
N-30
N-31 (2003) full size 12/8/03 7:17 PM Page 1
BOREMATIC
568-978 LUT
SO E
AB
Y
OG
EC
H N OL
T
Features
• LCD Readout .00005"/0.001mm. • Rotatable display unit for easy reading at any angle.
• Carbide tipped contact points ensure long life. • Functions include:
Origin setting, Origin restoration, Zero-setting,
• Efficient measurement using two measurement
Presetting, Data hold, Error alarm, Low-battery alarm,
modes—ABS (absolute) and INC (incremental) modes.
Data output.
• Can be linked to the M-SPC (Mitutoyo Statistical
• Power supply: SR44 (button-type silver oxide cell), 1 pc.
Process Control) system.
Specifications
Borematic Interchangeable-Head Sets
Inch/Metric
Set Set Display Adaptor Interchangeable Individual Setting Ring
Order No. Measuring Range Unit Supplied Contact Heads Range Supplied w/set
568-976 .275"–.5" 568-013 954595 952909 .275"–.35"/6.985–8.89mm 177-179(.35")
6.985–12.7mm 952910 .35"–.425"/8.89–10.795mm 177-283(.425")
952911 .425"–.5"/10.795–12.7mm
568-977 .5"–1.0" 568-013 216556 952670 .5"–.65"/12.7–16.51mm 177-182(.65")
12.7–25.4mm 952671 .65"–.8"/16. 51–20.32mm 177-287(.8")
216557 952672 .8"–1.0"/20.32–25.4mm
568-978 1.0"–2.0" 568-013 216557 952673 1.0"–1.2"/25.4–30.48mm 177-289(1.2")
25.4–50.8mm 982149 1.2"–1.6"/30.48–40.64mm 177-291(1.6")
982150 1.6"–2.0"/40.64–50.8mm
568-979 2.0"–4.0" 568-013 216558 982178 2.0"–2.5"/50.8–63.5mm 177-315(2.5")
50.8–101.6mm 982179 2.5"–3.0"/63.5–76.2mm
982180 3.0"–3.5"/76.2–88.9mm 177-319(3.5")
982181 3.5"–4.0"/88.9–101.6mm
568-980 2.0"–4.0" 568-013 216558 04AZA047* 2.0"–2.5"/50.8–63.5mm 177-315(2.5")
50.8–101.6mm 2.5"–3.0"/63.5–76.2mm
04AZA048* 3.0"–3.5"/76.2–88.9mm 177-319(3.5")
3.5"–4.0"/88.9–101.6mm
* Two sets of interchangeable contact points are provided.
For SPC output order connecting cable 937387(40"/1m) or 965013(80"/2m).
N-31
N-32 (2003) full size 12/8/03 7:20 PM Page 1
BOREMATIC
568-988 LUT
SO E c
AB
Y
OG
EC
H N OL
T
Unit:Inch (mm)
N-32
N-33 (2003) full size 12/8/03 7:21 PM Page 1
SETTING RINGS
Setting Rings
Series 177
Specifications
Inch Metric
Order Outside Order Outside
Size No. Accuracy Diameter Width Size No. Accuracy Diameter Width
.1" 177-209 1.75mm 177-236
.16" 177-206 2.0mm 177-239 5mm
.98" .28"
.24" 177-207 2.25mm 177-242
.275" 177-281 2.5mm 177-208
.35" 177-179 2.75mm 177-246
.425" 177-283 1.26" 3.0mm 177-248
.50" 177-180 3.25mm 177-250
.6" 177-181 1.5" .39" 3.5mm 177-252 25mm
.65" 177-182 3.75mm 177-255
.70" 177-183 1.77" 4.0mm 177-204 7mm
.8" 177-287 4.5mm 177-257
1.0" 177-184 2.09" 5.0mm 177-205
1.2" 177-289 ±.00006" 5.5mm 177-263
1.4" 177-185 2.8" .59" 6.0mm 177-267
1.6" 177-291 6.5mm 177-271
1.8" 177-186 7.0mm 177-275
3.35"
2.0" 177-187 8.0mm 177-125
2.4" 177-293 .79" 10.0mm 177-126 32mm
2.5" 177-315 4.41" 12.0mm 177-284 ±0.0015mm
2.8" 177-188 14.0mm 177-132 38mm 10mm
3.0" 177-317 16.0mm 177-177
4.92"
3.2" 177-295 17.0mm 177-133 45mm
3.5" 177-319 20.0mm 177-286
5.51" .98"
3.6" 177-189 25.0mm 177-139 53mm
4.0" 177-297 6.3" 30.0mm 177-288
5.0" 177-299 8.27" 35.0mm 177-140 71mm 15mm
6.0" 177-301 9.25" 40.0mm 177-290
7.0" 177-303 10.24" 45.0mm 177-178
85mm
8.0" 177-305 ±.00010" 12.24" 1.5" 50.0mm 177-146
9.0" 177-307 13.27" 60.0mm 177-292
20mm
10.0" 177-309 14.25" 62.0mm 177-314 112mm
11.0" 177-311 16.26" 70.0mm 177-147
12.0" 177-313 17.24" 75.0mm 177-316
125mm
80.0mm 177-294
87.0mm 177-318 25mm
140mm
Metric 90.0mm 177-148
Order Outside 100.0mm 177-296 160mm
Size No. Accuracy Diameter Width 125.0mm 177-298 210mm
1.0mm 177-220 150.0mm 177-300 235mm
1.1mm 177-222 175.0mm 177-302 260mm
1.2mm 177-225 ±0.0015mm 20mm 4mm 200.0mm 177-304 ±0.0025mm 311mm 38.1mm
1.3mm 177-227 225.0mm 177-306 337mm
1.4mm 177-230 250.0mm 177-308 362mm
275.0mm 177-310 413mm
300.0mm 177-312 438mm
N-33
N-34 (2003) full size 12/8/03 7:24 PM Page 1
MSG Models
MLS Models
Specifications
MSG Models MLS Models
Measuring Channels
Air 1 standard, (optional to 4 maximum) 1 standard
LVDT optional to 8 maximum 2 standard
Digital optional 4, 8, 16 N/A
Measuring Programs 4 standard, optional 9 or 18 4 standard
Resolution .1µm minimum .1 µm minimum
Communication Ports
RS232C 1 standard (optional to 2 maximum) 1 standard
RJ485 optional (2x) 2 standard
USB optional N/A
Opto I/O standard standard
Ethernet standard N/A
Program switch Connector standard standard
Printer Port optional optional
The MSG model column is fully configurable to any air electronic application. Unit can act as master or slave in control feed
back environment. Display graphics are also configurable to your specific requirements. Please contact Mitutoyo America
Corporation representatives for further information.
The MLS model is offered as a limited measurement purpose device using a single air and two LVDT channels. LVDT's are 5
pin, half bridge style.
Mitutoyo also offers a complete line of air gage tooling to support our columns as well as the capability to supply tooling and
masters in many configurations for most competitive brands. In addition we can ship all gages with a long form certification
from our calibration labs.
N-34
N-35 (2003) full size 12/8/03 7:26 PM Page 1
CHAMFER-CHEK
Chamfer Chek
Series 526 – I.D. Measures the top diameter of tapered holes and chamfers
O.D. measures the minor end diameter of tapered conical parts
I.D. O.D.
526-005C 526-008C
N-35
N-36 (2003) full size 12/8/03 7:28 PM Page 1
CHAMFER-CHEK
I.D. O.D.
547-480 547-482
Standard Accessories
Master Plate (64AAA012), 3"(W) x 2"(D) x .925"(H)
Black Leather Case (21BZA778) 9.7"(W) x 2"(D) x 6.1"(H)
*Wooden box (21BZA779) 12.8"(W) x 5.1"(D) x 3.63"(H)
* 547-481 (DC1-2090) only
N-36
N-37 (2003) full size 12/8/03 7:29 PM Page 1
HOLE-CHEK
Hole Chek
Series 526 – Instant Diameter Measurement of Small Holes
526-003H 526-001H
Features Specifications
• Ease of Operation: Simply insert the steel plunger into Accuracy: .001"
the hole and press firmly against the part and read the Graduation: .001" Dia.
diameter directly to three decimal places.
Gage Weight: 526-001H 1 lbs. (454g)
• Resolution: Reads directly in .001" diameter incre- 526-002H 1 lbs. (454g)
ments. 526-003H 1 lbs. (454g)
• Applications: Inspect PC boards, screw machine parts, 526-004H 1 lbs. (454g)
spray tips, injector nozzles, plastic molded parts.
Order No. Model No. Dia. Range
Standard Accessories 526-001H HC-0040 .010"–.040"
Wooden Box: 12.8"(W) x 5.1"(D) x 3.2"(H) 526-002H HC-0130 .030"–.130"
Granite Plate: 3"(W) x 2"(D) x .925"(H) (64AAAO12) 526-003H HC-0230 .130"–.230"
526-004H HC-0330 .230"–.330"
Optional Accessories
Setting Master (O.D. = .76"/H = .29")
Order No. Model No. Diameter
64AAA003 SM-040 .029"
64AAA004 SM-130 .078"
64AAA005 SM-230 .178"
64AAA006 SM-330 .278"
N-37
O-01 (2003) full size 12/12/03 3:10 PM Page 1
Calipers
Digimatic Calipers w/Absolute Encoders - Series 500 -
without SPC output O-2
Digimatic Calipers w/Absolute Encoders - Series 500 O-3, 4
Digimatic Solar Powered Caliper w/Absolute Encoder -
Series 500 O-5, 6
Coolant Proof Digimatic Caliper w/Abs. Enc. (IP-66) -
Series 500 O-7
Digimatic Plastic Calipers - Plasti-Cal Series 700, MyCal Lite -
Series 700 O-8
Dial Calipers - Series 505 O-9, 10, 11, 12
Digimatic Calipers with Absolute Encoder - Series 550 O-13, 14
Heavy Duty Dial Caliper - Series 504 O-13, 14
Digimatic Snap Calipers w/Absolute Encoders - Series 573 O-15
Digimatic Carbon Fiber Calipers - Series 552 O-16, 17
Digimatic Versa Gage - Series 552 O-18,19
Digimatic Calipers with Absolute Encoder - Series 551 O-20
Digimatic Special Face Calipers with Absolute Encoder -
Series 573 O-21, 22
Digimatic Inside Calipers with Absolute Encoder -
Series 573 O-23, 24
Offset Calipers - Series 573, 536 O-25, 26
Offset Centerline Calipers - Series 573, 536 O-27
Digimatic Point Calipers with Absolute Encoder - Series 573 O-28
Low Pressure Calipers - Series 573, 536 O-29
How to Read Vernier Calipers O-30, 31
Precision Vernier Calipers - Series 530, 531, 532 O-32~34
Diamond Master Vernier Calipers - Series 522 O-35
Vernier Calipers - Series 160, 534 O-36, 37
Center Line Gage O-38
Calipers Depth Base Attachment O-39
O-02 (2003) full size 12/8/03 9:51 PM Page 1
CALIPERS
500-196
Rear view
LUT showing step
SO E
AB
measuring
feature.
Y
OG
EC
H N OL
Introducing the new Digimatic MyCal E-Z Caliper T • A scale contamination detection function is implement-
featuring ABSOLUTE LINEAR ENCODER technology. It ed to detect contamination of surface and display the
has achieved superior cost performance and ease of use error message (ErrC) on the LCD. The correct value is
by featuring only essential functions. only displayed if the contamination is removed.
Features • The battery life has been greatly extended with the
power-conserving design permitting 3.5 years (20,000
• The Absolute MyCal E-Z allows direct measurements hours) continuous operation with a single battery.
from power on. You can forget the time consuming
origin setup which otherwise is required each time the Specifications
power is turned on.
Quantizing Error:
± 1 count
• Zero-setting of the display is also possible at any slider
Function: ORIGIN Setting
position for easy comparison measurements (incremen-
tal mode). ZERO/ABS, ON/OFF
• Large .295" high LCD digits (.365" high LCD digits for Inch/Metric
12" Model) allow measurement results to be at a Response Speed: Unlimited
glance. Battery: Silver oxide cell SR-44 (1 pc.)
Specifications Part No. 541980
Digimatic Calipers with Absolute Encoder Battery Life: Approx. 20,000 hrs. (continuous
Inch/Metric (Non-SPC Output Models) operation)
Order No. Measuring Range LCD Resolution Accuracy (20° C) Remarks
500-195 0–4” .0005” ± .001” .075 Round depth bar
0–100mm 0.01mm
500-196 0–6” .0005” ± .001”
0–150mm 0.01mm
500-159 0–6” .0005” ± .001” with OD Carbide Jaw
0–150mm 0.01mm
500-160 0–6” .0005” ± .001” with OD, ID Carbide Jaw
0–150mm 0.01mm
500-197 0–8” .0005” ± .001”
0–200mm 0.01mm
500-163 0–8” .0005” ± .001” with OD Carbide Jaw
0–200mm 0.01mm
500-164 0–8” .0005” ± .001” with OD, ID Carbide Jaw
0–200mm 0.01mm
500-193 0–12” .0005” ± .0015”
0–300mm 0.01mm
500-165 0–12” .0005” ± .0015” with OD Carbide Jaw
0–300mm 0.01mm
500-166 0–12” .0005” ± .0015” with OD, ID Carbide Jaw
0–300mm 0.01mm
Replacement Battery: 541980 ( 1 pc.), 541980-10 (10 pcs./SET)
O-2
O-03 (2003) full size 12/8/03 9:52 PM Page 1
CALIPERS
500-171
LUT
SO E
AB
Y
OG
EC
H N OL
T
Optional Accessories
SPC Connecting Cables Add-on
No.959149(1m), No.959150(2m) Hold Switch HOLD
DATA
Data Switch
OFF ON/ZERO
MITUTOYO’s new Absolute position). Once set, the Absolute mode and display of the true
Encoder Digimatic Caliper offers Encoder caliper will switch on position from the origin point.
special functions which allow it to showing its true position from the Also provided is inch/mm conver-
always remember its measuring origin point rather than 0.0000 as sion and SPC data output. Another
position even after the gage has with standard models. outstanding feature of the Absolute
been switched off. • Zero/ABS: Allows the display to Encoder Digimatic Caliper is 3.5
• Origin: Allows setting of an origin be Zero-Set at any point along the years of use under normal working
starting point to be used as refer- slider for incremental comparison conditions from just a single SR44
ence in subsequent measure- measurements. This switch will battery cell. (541980)
ments (generally set to closed jaw also allow return to the absolute
Specifications
Digimatic Calipers with Absolute Encoder
Metric (SPC output models)
LCD
Order No. Range Resolution Accuracy Remarks
500-150 0–100mm 0.01mm ±0.02mm 1.9mm Round Depth Bar.
500-151 0–150mm 0.01mm ±0.02mm
500-152 0–200mm 0.01mm ±0.02mm
500-153 0-300mm 0.01mm ±0.03mm
500-500-10 0–450mm 0.01mm ±0.05mm without Depth Bar, Absolute
Function Type
500-501-10 0–600mm 0.01mm ±0.05mm without Depth Bar, Absolute
Function Type
For SPC output order Connecting Cable 959149 (1m) or 959150 (2m).
Replacement Battery: 541980 (1pc), 541980-10 (10 pcs/SET)
O-3
O-04 (2003) full size 12/8/03 9:53 PM Page 1
CALIPERS
L
D
B C G
ABSOLUTE F
A
Battery Cover
Dimensions
Order No. A B C D E F G L
500-170, 500-195 1.57" .83" .65" 2.26" 1.42" .63" .138" 7.09"
500-171, 500-196, 1.57" .83" .65" 2.26" 1.42" .63" .138" 9.10"
500-159, 500-160,
500-175, 500-178,
500-174
500-172, 500-197, 1.97" .96" .79" 2.26" 1.42" .63" .138" 11.34"
500-163, 500-164,
500-176, 500-177
500-173, 500-193, 2.52" 1.08" .86" 2.80" 1.60" .79" .15" 15.87"
500-165, 500-166,
500-167, 500-168
500-505-10 3.54" 1.85" 1.50" 3.61" 2.44" .98" .24" 24.80"
500-506-10 3.54" 1.85" 1.50" 3.61" 2.44" .98" .24" 30.70"
500-507-10 5.11" 2.36" 1.65" 4.49" 2.87" 1.26" .31" 48.82"
500-150 1.57" .83" .65" 2.26" 1.42" .63" .138" 7.09"
500-151 1.57" .83" .65" 2.26" 1.42" .63" .138" 9.10"
500-152 1.97" .96" .79" 2.26" 1.42" .63" .138" 11.34"
500-153 2.52" 1.08" .86" 2.80" 1.60" .79" .15" 15.87"
500-500-10 3.54" 1.85" 1.50" 3.61" 2.44" .98" .24" 24.80"
500-501-10 3.54" 1.85" 1.50" 3.61" 2.44" .98" .24" 30.70"
O-4
O-05 (2003) full size 12/8/03 9:54 PM Page 1
CALIPERS
500-464
LUT
SO E
AB
Y
OG
EC
H N OL
T
500-474
Optional Accessories:
SOLAR ABSOLUTE MyCAL
(For output models only)
DIGIMATIC CALIPER
SPC Connecting Cables
The Solar Absolute MyCAL is Mitutoyo's latest
No.959149(1m), No.959150(2m)
advancement in caliper technology.
DATA
HOLD
OFF ON/ZERO
O-5
O-06 (2003) full size 12/8/03 9:54 PM Page 1
CALIPERS
E Dimensions
Order No. A B C D E F G t❈
C
500-463
7.1"
500-490
G
F
3.03" .65" 1.57"
500-464
B
500-465
11.34" 3.56" .79" 1.97"
500-492
A
❈ t : Jaw Thickness
Output Specifications
5 4 3
Pin No. Signal I/O Description
2
1 1 GND — Ground
2 *1 DATA O Measurement data
DAT
A/H
OLD
3 *1 CK O Clock for data transmission
4 RD O Ready for data transmission
5 *2 REQ 1 Request for data transmission
*1 Open drain: -0.3 ~ +7.0V, 400µA max.
*2C-MOS: Pull-up to VDD(1.55V)
Specifications
Digimatic Solar Powered Calipers with Absolute Encoder
Inch/Metric
LCD
Order No. Range Resolution Accuracy Remarks
500-463 0–4" .0005" ±.001" .075" Round Depth Bar
0–100mm 0.01mm with SPC output
500-464 0–6" .0005" ±.001" with SPC output
0–150mm 0.01mm
500-465 0–8" .0005" ±.001" with SPC output
0–200mm 0.01mm
500-473 0–4" .0005" ±.001" .075" Round Depth Bar
0–100mm 0.01mm without SPC output
500-474 0–6" .0005" ±.001" without SPC output
0–150mm 0.01mm
500-475 0–8" .0005" ±.001" without SPC output
0–200mm 0.01mm
For SPC output order Connecting Cable 959149 (1m) or 959150 (2m). Note: Solar Cells should be maintained over 60 lux.
O-6
O-07 (2003) full size 12/10/03 11:10 AM Page 1
CALIPERS
Technical Data
Quantizing Error: ± 1 Count.
Repeatability: .0005"/0.01mm
Display: LCD (Character height: .3"/7.5mm)
Functions: Origin setting, Automatic power on/off*1 IP66 Protection
Inch/mm conversion, Data output
Type Level Definition
Dust/Water Protection
Level: IP66 (IEC 60529) Operator-safe and 6: Protection Protect the equipment
Battery: SR44 (1pc.) up to 8" (2pc.) for 12" protection against against dust against dust not to
Battery Life (0-6"): Approx. 3-year under normal use foreign matter penetrate.
Battery Life (0-12"): Approx. 1-year under normal use Protect against 5: Protection Protect the equipment
Measuring System: Electromagnetic induction type absolute water against water against water jet that’s*
linear encoder*2 jet from any direction.
Response Speed: Unlimited * Condition: Using a nozzle with 12.5mm ID and water jet with 30Kpa
*1 Patent pending (Japan, U.S.A., China, UK, France) water pressure (approx. 100L/min) on the equipment from a distance
*2 Design pending (Japan, U.S.A., China, UK, France) of a meter for 3 minutes or over (1 minute per 1m2 superficial area).
Specifications
Order No. Measuring Range LCD Resolution Accuracy Remarks
500-672 0-6"/0-150mm .0005"/0.01mm ± .001"
500-682 0-6"/0-150mm .0005"/0.01mm ± .001" With SPC Output
500-673 0-8"/0-200mm .0005"/0.01mm ± .001"
500-683 0-8"/0-200mm .0005"/0.01mm ± .001" With SPC Output
500-674 0-12"/0-300mm .0005"/0.01mm ± .0015"
500-684 0-12"/0-300mm .0005"/0.01mm ± .0015" With SPC Output
O-7
O-08 (2003) full size 12/8/03 9:56 PM Page 1
CALIPERS
700-126 700-103Y
MyCal Lite
Series 700 – Economy version Digimatic Caliper
with all steel construction
700-113
O-8
O-09 (2003) full size 12/8/03 9:58 PM Page 1
CALIPERS
Dial Calipers
Series 505
505-675
505-717
Specifications
Dial Calipers
Inch
Order No. Range Dial Reading Accuracy Remarks
Resolution Range/Rev. (20•)
505-716 0–4" .001" .20" ±.001" Dial Face: A
505-674 0–4" .001" .10" ±.001" Dial Face: B
505-717 0–6" .001" .20" ±.001" Dial Face: A
505-675 0–6" .001" .10" ±.001" Dial Face: B
505-675-51 0–6" .001" .10" ±.001" Blue Dial Face, Dial Face: B
505-675-52 0–6" .001" .10" ±.001" Purple Dial Face, Dial Face: B
505-675-53 0–6" .001" .10" ±.001" Green Dial Face, Dial Face: B
505-675-54 0–6" .001" .10" ±.001" Red Dial Face, Dial Face: B
505-675-55 0–6" .001" .10" ±.001" Orange Dial Face, Dial Face: B
505-675-56 0–6" .001" .10" ±.001" Black Dial Face, Dial Face: B
505-675-66 0–6" .001" .10" ±.001" Black Dial Face, Dial Face: B
with Ratchet Stop
505-718 0–6" .001" .20" ±.001" Dial Face: A with OD Carbide Jaw
505-708 0–6" .001" .10" ±.001" Dial Face: B with OD Carbide Jaw
505-712 0–6" .001" .10" ±.001" Dial Face: B with OD, ID Carbide Jaw
505-689 0–6" .001" .10" ±.001" Dial Face: B Extra Smooth Movement
505-690 0–8" .001" .10" ±.002" Dial Face: B Extra Smooth Movement
505-719 0–8" .001" .20" ±.002" Dial Face: A
505-676 0–8" .001" .10" ±.002" Dial Face: B
505-709 0–8" .001" .10" ±.002" Dial Face: B with OD Carbide Jaw
505-713 0–8" .001" .10" ±.002" Dial Face: B with OD, ID Carbide Jaw
505-720 0–12" .001" .20" ±.002" Dial Face: A
505-721 0–12" .001" .20" ±.002" Dial Face: A with OD Carbide Jaw
505-677 0–12" .001" .10" ±.002" Dial Face: B
505-710 0–12" .001" .10" ±.002" Dial Face: B with OD Carbide Jaw
505-714 0–12" .001" .10" ±.002" Dial Face: B with OD, ID Carbide Jaw
O-9
O-10 (2003) full size 12/17/03 9:20 AM Page 1
CALIPERS
G
B
Dimensions
Order No. A B C D H E F G t❈
505-674
7.1"
505-716
505-675
505-675-51
505-675-52
505-675-53
505-675-54
505-675-55
505-675-56 9.1" 3.03" .65" 1.57" .83" 2.25" 1.5" .63" .35"
505-675-66
505-689
505-708
505-712
505-717
505-718
505-676
505-690
505-709 11.34" 3.56" .79" 1.97" .96"
505-713
505-719
505-677
505-710
505-714 15.9" 4.4" .87" 2.52" 1.08" 2.7" 1.7" .79" .15"
505-720
505-721
❈ t : Jaw Thickness
O-10
O-11 (2003) full size 12/8/03 10:02 PM Page 1
CALIPERS
Dial Calipers
Series 505
505-671
Features
• Imporoved durability, the sliding surfaces of the
main blade are coated with titanium.
• Shock proof construction 1mm revolution models. 505-681
• Supplied in fitted carrying case.
Specifications
1mm / Revolution
Metric
Dial Reading
Order No. Range Resolution Range/Rev. Accuracy Remarks
505-680 0–100mm 0.01mm 1.0mm ±0.015mm Dial Face: C
505-681 0–150mm 0.01mm 1.0mm ±0.02mm Dial Face: C
505-682 0–150mm 0.01mm 1.0mm ±0.03mm Dial Face: C
2mm / Revolution
Metric
Dial Reading
Order No. Range Resolution Range/Rev. Accuracy Remarks
505-671 0–150mm 0.02mm 2.0mm ±0.03mm Dial Face: D
505-707 0–150mm 0.02mm 2.0mm ±0.03mm Dial Face: D with OD carbide jaw
505-711 0–150mm 0.02mm 2.0mm ±0.03mm Dial Face: D with OD, ID carbide jaw
505-683 0–150mm 0.02mm 2.0mm ±0.03mm Dial Face: D with extra smooth movement
505-672 0–200mm 0.02mm 2.0mm ±0.03mm Dial Face: D
505-684 0–200mm 0.02mm 2.0mm ±0.03mm Dial Face: D with extra smooth movement
505-673 0–300mm 0.02mm 2.0mm ±0.04mm Dial Face: D
O-11
O-12 (2003) full size 12/15/03 10:13 AM Page 1
CALIPERS
G
B
Dimensions unit:mm
Order No. A B C D H E F G t❈
505-680 180
505-671
505-681
505-683 231 77 16.5 40 21 57.2 39.5 16 3.5
505-707
505-711
505-672
505-682 288 90.5 20 50 24.5
505-648
505-714 403 111.5 22 64 27.5 70.2 43.4 20 3.8
❈ t : Jaw Thickness
O-12
O-13 (2003) full size 12/8/03 10:04 PM Page 1
CALIPERS
LUT
SO E
AB
550-225-10
OG
EC
H N OL
T
504-106
Features
• Provides highly repeatable inside measurements.
• Direct reading of inside dimensions.
O-13
O-14 (2003) full size 12/8/03 10:04 PM Page 1
CALIPERS
550-225-10 30.71 2.56 3.94 .25 .71 .98 .236 ON/OFF ZERO/ABS
R=.20" D
Specifications
Heavy Duty Digimatic Calipers with Absolute Encoder
Inch/Metric (with SPC output)
Range LCD
Order No. Outside Inside Resolution Accuracy Remarks
550-221-10 0–8" .4–8" .0005" ±.001"
0–200mm 10.16–200mm 0.01mm without Depth Bar
Absolute Function Type
550-241-10 0–12" .4–12" .0005" ±.0015"
0–300mm 10.16–300mm 0.01mm without Depth Bar
550-223-10 0–18" .5–18" .0005" ±.002"
0–450mm 12.7–450mm 0.01mm without Depth Bar
Absolute Function Type
550-225-10 0–24" .5–24" .0005" ±.002"
0–600mm 12.7–600mm 0.01mm without Depth Bar
Absolute Function Type
550-227-10 0–40" 1.0–40" .0005" ±.003"
0–1000mm 25.4–1000mm 0.01mm without Depth Bar
Absolute Function Type
Absolute Function Type SPC Connecting Cable: 959149 (1m) or 959150 (2m).
O-14
O-15 (2003) full size 12/8/03 10:05 PM Page 1
CALIPERS
Locking clamp
573-281-10
Spring loaded
thumb lever
LUT
SO E
AB
Y
This special version of MITUTOYO’s This caliper also features the new
OG
EC
Digimatic Caliper features a spring- Absolute scale which always knows H N OL
T
loaded mechanism to allow quick its true position from the origin
and efficient GO/±NG inspection. point.
Set-up is a simple operation as
shown below.
1. Push the whole sliding unit 2. Use zero-set function to zero the 3. Open and close jaws with snap
against your masterpiece. Digimatic display. lever to check workpieces
(Gage Block used here) allows .079"(2mm) retraction.
Lock with clamp.
Specifications
Digimatic Snap Calipers with Absolute Encoder
Inch/Metric
LCD
Order No. Range Resolution Accuracy Remarks
573-281-10 0–4" .0005" ±.001" with SPC output
0–100mm 0.01mm Absolute Function Type
573-282-10 0–6" .0005" ±.001" with SPC output
0–150mm 0.01mm Absolute Function Type
For SPC output order Connecting Cable 959149 (1m) or 959150 (2m). Replacement Battery: 541980 (1pc), 541980-10 (10 pcs/SET)
O-15
O-16 (2003) full size 12/8/03 10:05 PM Page 1
CALIPERS
552-313
552-160
These large Digimatic Calipers have a beam constructed and inside dimensions. Optional attachments available for
of a strong carbon fiber which makes them both durable special measurements.
and easy to handle. Standard jaws will take both outside
Features
• Lightweight Digimatic caliper that employs CFRP Zero-setting, Data hold, Error alarm, Low battery alarm,
(Carbon Fiber Reinforced Plastics) in the beam and Data output. (Note: Data hold and output functions can-
jaws. not be used at the same time.)
• The range of applications can be expanded by using • Power supply: One SR44 (541980)
the optional attachments. • Battery life: Approx. two years under normal use
• Display: 6-digit LCD with a minus sign (-) (Approx. one year in continuous operation)
• Functions include: • Provided with a data output port for connection with the
Preset of desired starting point SPC system.
Inch/mm conversion
Specifications
Digimatic Carbon Fiber Calipers
Inch/Metric (with SPC output)
Range Range LCD
Order No. Outside Inside Resolution Accuracy Remarks
552-160 0–18" .5–18.5" .0005" ±.003" Jaw Depth: 7.9"
0–450mm 12.7–462mm 0.01mm
552-161 0–24" .5–24.5" .0005" ±.003" Jaw Depth: 7.9"
0–600mm 12.7–612mm 0.01mm
552-165 0–18" .5–18.5" .0005" ±.002" with Ceramic Jaws
0–450mm 12.7–462mm 0.01mm
552-166 0–24" .5–24.5" .0005" ±.002" with Ceramic Jaws
0–600mm 12.7–612mm 0.01mm
552-311 0–12" .5–12.5" .0005" ±.0015"
0–300mm 12.7–312mm 0.01mm
552-312 0–18" .5–18.5" .0005" ±.002"
0–450mm 12.7–462mm 0.01mm
552-313 0–24" .5–24.5" .0005" ±.002"
0–600mm 12.7–612mm 0.01mm
552-314 0–40" 1.0–41" .0005" ±.003"
0–1000mm 25.4–1025mm 0.01mm
552-315 0–60" 1.0–61" .0005" ±.0035"
0–1500mm 25.4–1525mm 0.01mm
For SPC output order Connecting Cable 905338 (1m) or 905409 (2m). Replacement Battery: 541980 (1 pc.), 541980-10 (10 pcs./SET)
O-16
O-17 (2003) full size 12/8/03 10:06 PM Page 1
CALIPERS
L
5 Output connector
A B
Beam
INSIDE DIGIMATIC
C
Main scale
2 Slider stopper
OFFSET value label
4 3
1
6
E
Slider
Jaw, Beam
F G
Switch function I
1 ON/OFF
2 ZERO
3 OFFSET
4 PRESET
5 DATA/HOLD
6 in/mm
Dimensions (Unit: Inch)
Order No. L A B C D E F G H I J
552-311 19.3 1.62 3.61 .98 2.56 3.94 .25 .71 .50 .31 .31
552-312
25.2 1.62 3.61 .98 2.56 3.94 .25 .71 .50 .31 .31
552-165
552-160 25.2 1.62 3.61 .98 2.56 7.9 .25 .71 .50 .31 .31
552-313
31.1 1.62 3.61 .98 2.56 3.94 .25 .71 .50 .31 .31
552-166
552-161 31.1 1.62 3.61 .98 2.56 7.9 .25 .71 .50 .31 .31
552-314 48.8
2.47 4.8 1.26 3.94 5.90 0.50 .94 1.00 .47 .31
552-315 68.5
3.7"
DIMENSIONS
914016 — 2.05"
A 914048 — 2.44"
B 880099 — .40"
C 880099 — .40"
D 914018 — 1.0"
E 914018 — 2.0"
O-17
O-18 (2003) full size 12/8/03 10:06 PM Page 1
CALIPERS
552-281
Features
• Lightweight gage employing Carbon Fiber Reinforced Plastics • Inch/Metric
in the beam. • SPC output.
• 6" and 12" Models are hardened stainless steel. • Hold button allowing operator to take accurate measurements
• An expandable variety of applications. in difficult and awkward positions.
• Easy to read 6 digit LCD display with resolutions to .0005”
increments.
Specifications
Digimatic Versa Gage
Inch/Metric
Order No. Linear Range Cone Range Depth Range Resolution Accuracy
0-18” 1.125-19.1” 14” .0005”
552-281 ±.002”
0-460mm 28.5-485mm 355mm 0.01mm
0-24” 1.125-25.5” 14” .0005”
552-282 ±.002”
0-620mm 28.5-647mm 355mm 0.01mm
0-40” 1.35-42.3” 23” .0005”
552-283 ±.003”
0-1040mm 34-1075mm 584mm 0.01mm
0-60” 1.35-62.6” 23” .0005”
552-284 ±.0035”
0-1554mm 34-1590mm 584mm 0.01mm
0-80” 1.35-86.5” .0005”
552-285 NA ±.0045”
0-2170mm 34-2197mm 0.01mm
0-6” .75-6.9” 6” .0005”
552-286* ±.0015”
0-152.4mm 19-175mm 152.4mm 0.01mm
0-12” .75-12.75” 7.5” .0005”
552-287* ±.0015”
0-322mm 19-322mm 190mm 0.01mm
*Optional accessories are not available for 6" and 12" models.
O-18
O-19 (2003) full size 12/8/03 10:07 PM Page 1
CALIPERS
Optional Accessories*
Order No. Description
64AAA520 ø2.25" Cone Center Extender (Pair)
64AAA521 ø3.62" Cone Center Extender (Pair)
64AAA522 ø5" Cone Center Extender (Pair)
64AAA523 ø.5" Cone Center Reducer (Pair)
64AAA524 ø.75" Cone Center Reducer (Pair)
64AAA525 Flange Pin Reducer Block
#34 Single Cone #4-48 Tapped for 40", 60",
64AAA526
80" Gages
#34 Dual Cone #4-48 Tapped for 40", 60",
64AAA527
80" Gages
64AAA528 #28.5 Dual Cone #4-48 for 18", 24" Gages
64AAA529 #28.5 Single Cone #4-48 for 18", 24" Gages Cone Extenders
64AAA530 Edge Guides for 40", 60" 80"
64AAA531 Edge Guides for 18", 24"
64AAA532 Wooden Box for 18"
64AAA533 Wooden Box for 24"
64AAA534 Wooden Box for 40"
64AAA535 Wooden Box for 60"
64AAA536 Wooden Box for 80"
905338 SPC output cable (1m)
905409 SPC output cable (2m)
541980 SR44 Battery
*6" and 12" models cannot use optional accessories.
Cone Reducers
O-19
O-20 (2003) full size 12/8/03 10:07 PM Page 1
CALIPERS
551-224-10
LUT
SO E
AB
Y
OG
EC
H N OL
T
L
Dimensions (Unit: inch)
A Order No. L A B C D E F G
G
ON 551-221-10 11.34 1.18 1.69 2.36 .20 .31 .63 .118
ABSOLUTE F
551-241-10 15.87 1.57 2.68 3.54 .20 .39 .79 .150
0 10 20 IN
MIN
ON/OFF ZERO/ABS
Specifications
Digimatic Caliper with Absolute Encoder
Inch/Metric (with SPC output)
Range Range LCD
Order No. Outside Inside Resolution Accuracy Remarks
551-221-10 0–8" .4–8" .0005" ±.001"
0-200mm 10.16-200mm 0.01mm without Depth Bar, Absolute Function Type
551-241-10 0–12" .4–12.4" .0005" ±.002"
0-300mm 10.16-310.16mm 0.01mm without Depth Bar
551-224-10 0–20" .5–20" .0005" ±.0025"
0-500mm 12.7-500mm 0.01mm without Depth Bar, Absolute Function Type
551-226-10 0–30" .5–30" .0005" ±.003"
0-750mm 12.7-750mm 0.01mm without Depth Bar, Absolute Function Type
551-227-10 0–40" 1.0–41" .0005" ±.003"
0-1000mm 25.4-1025mm 0.01mm without Depth Bar, Absolute Function Type
SPC Connecting Cable: 959149 (1m) or 959150 (2m). Replacement Battery: 541980 (1 pc.), 541980-10 (10 pcs./SET)
O-20
O-21 (2003) full size 12/8/03 10:08 PM Page 1
CALIPERS
573-234-10
Blade Type
Digimatic Caliper
573-251-10
Neck Type
Digimatic Caliper
573-252-10
Outside Point Type
Digimatic Caliper
LUT
SO E 573-261-10
AB
Digimatic Caliper
OG
EC
H N OL
T
These calipers offer some additional special jaw styles The Absolute scale always knows its true position from
for difficult to reach dimensions. the origin point and never needs zero-setting.
Additionally, these models incorporate Mitutoyo's exclu-
sive Absolute reading scale.
Specifications
Digimatic Special Face Calipers with Absolute Encoder
Inch/Metric (with SPC output)
LCD
Order No. Range Resolution Accuracy Remarks
573-234-10 0–6" .0005" ±.001" Blade type
0–150mm 0.01mm & OD Carbide Jaw
573-251-10 0–6" .0005" ±.0015" Neck type,
0–150mm 0.01mm without Depth Bar
573-252-10 0–6" .0005" ±.0015" Outside Point Type
0–150mm 0.01mm without Depth Bar
573-261-10 0–6" .0005" ±.002" Tube Thickness type
0–150mm 0.01mm without Depth Bar
*For SPC order Connecting Cable 959149 (1m) or 959150 (2m).
All models listed above operate on a single SR-44 battery which lasts approximately 3.5 years with normal use.
Replacement Battery: 541980 (1pc), 541980-10 (10 pcs/SET)
O-21
O-22 (2003) full size 12/8/03 10:09 PM Page 1
CALIPERS
in/mm DATA/HOLD
in/mm DATA/HOLD
OFF ON /ZERO
OFF ON /ZERO
1.57"
1.57"
1.38"
.39"
.03"
.79"
.20"
Outside Pointed Type Tube Thickness Type
1.50"
1.57"
ø.09"
ø.02"
30°
.20" ø.12"
30°
.39"
O-22
O-23 (2003) full size 12/8/03 10:09 PM Page 1
CALIPERS
573-246-10
Inside Pointed Jaw
Type Absolute
Encoder Digimatic
Caliper
573-245-10
Inside Groove Type
Absolute Encoder
Digimatic Caliper
573-242-10
Inside Knife-Edge Type
LUT
Absolute Encoder SO E
AB
Digimatic Caliper
Y
OG
EC
H N OL
T
Features
• Specially designed for inside measurements in hard to • Power Supply: Silver oxide cell (SR-44 1 pc.)
reach places. • Battery Life: 3.5 years under normal use.
• The Digimatic Caliper provides digital readout to
.0005"/0.01mm for error-free reading.
• All Digimatic models provide
SPC output. Additionally, these models incorporate
Mitutoyo's exclusive Absolute reading scale. The
Absolute scale always knows its true position from the
origin point and never needs zero-setting.
Specifications
Digimatic Inside Calipers with Absolute Encoder
Inch/Metric (with SPC output)
LCD
Order No. Range Resolution Accuracy Remarks
573-242-10 0"– 8" .0005" ±.002" Knife-edge type,
0-200mm 0.01mm Without Depth Bar
573-245-10 .4"– 6" .0005" ±.002" Inside groove type,
10.16-150mm 0.01mm Without Depth Bar
573-246-10 .8"– 6" .0005" ±.0015" Pointed jaw type,
20.32-150mm 0.01mm Without Depth Bar
Metric (with SPC output)
LCD
Order No. Range Resolution Accuracy Remarks
573-146-10 20 –150mm 0.01mm ±0.03mm Pointed jaw type,
Without Depth Bar
For SPC output order connecting cable 959149 (1m) or 959150 (2m). Replacement Battery: 541980 (1pc), 541980-10 (10 pcs/SET)
O-23
O-24 (2003) full size 12/8/03 10:10 PM Page 1
CALIPERS
Inside Point
Additional values for width of jaws imprinted on frame. Digimatic Inside Pointed Jaw
+.8 in.
IN/MM
+20.32mm DATA/HOLD
+.4 in.
1.57"
1.50"
+10.16mm
30°
ø.02"
ø.09"
.2"
.4" .4"
.8"
IN/MM IN/MM
DATA/HOLD
DATA/HOLD
0.0000 1.4800
OFF ON/ZERO
OFF ON/ZERO
1.38"
.79"
2.76"
.12"
.12"
.31"
.01"
.12"R
.14"
.2" .2"
.4"
O-24
O-25 (2003) full size 12/8/03 10:10 PM Page 1
CALIPERS
Offset Calipers
Series 573, 536
573-201-10
Offset Type
Digimatic Caliper
536-401
Offset Vernier
Caliper
LUT
SO E
AB
536-701
Offset Dial
Y
OG
Caliper EC
H N OL
T
A B
C
Features
• Main scale jaw can slide up and also incorporate Mitutoyo's exclu-
down to facilitate measurement of sive Absolute reading scale.
stepped sections. • All models feature a depth rod.
• The Digimatic Calipers provide digi- Hard-to-get-at dimensions such as
tal readout to .0005"/0.01mm for A, B, C, can be accurately mea-
error-free reading. These models sured with an offset vernier caliper.
Specifications
Offset Digimatic Calipers with Absolute Encoder
Inch/Metric (with SPC output)
LCD
Order No. Range Resolution Accuracy
573-201-10 0–6" .0005" ±.001"
0–150mm 0.01mm
573-202-10 0–8" .0005" ±.001"
0–200mm 0.01mm
573-203-10 0–12" .0005" ±.0015"
0–300mm 0.01mm
*For SPC output order Connecting Cable 959149 (1m) or 959150 (2m).
All models listed above operate on a single SR-44 battery which lasts approximately 3.5 years with normal use.
Replacement Battery: 541980 (1pc), 541980-10 (10 pcs/SET)
O-25
O-26 (2003) full size 12/8/03 10:11 PM Page 1
CALIPERS
A
B
Dimensions (Unit: inch)
Order No. A B C D E F G H
C
H 573-201-10 9.21 .295 .65 3.74 .394 1.57 .63 .138
20
2n
0 70 ABSOLUTE
DIGIMATIC G 573-202-10 11.53 .335 .79 3.74 .394 1.97 .63 .138
573-203-10 15.87 .472 .86 5.31 .60 2.52 .79 .15
D
F
T: Jaw Thickness
JAW
F
E
S
t
O-26
O-27 (2003) full size 12/8/03 10:11 PM Page 1
CALIPERS
573-206-10
Offset Centerline in/mm ORGIN
ABSOLUTE
Digimatic Type in
DIGIMATIC B
ON/OFF ZERO/ABS
E
C
LUT
SO E
AB
536-405
Y
OG
ØF
Offset Centerline EC
H N OL
T
D
Vernier Type
Dimensions (Unit: inch)
Order No. A B C D E øF *t Hole Diameter
Measures center to cen- 536-105 .394
ter on the even and off- 1.06 .118
536-405 8.86 .06–.394
set planes. Also mea- .63 2.95 .0394
573-205-10 .40
sures from edge to cen- 1.18 .138
573-206-10 11.10
ter. Direct reading (cen-
ter distances). * t: Jaw Thickness
Specially designed offset vernier and Digimatic calipers of .2" (5mm in metric) should be subtracted from the
are used for center to center distance measurements on measured dimensions in this case.
the same and offset planes. The movable jaw is approximately 3" long and adjustable
These calipers also measure from edge to center. A sum by means of the clamp provided.
Features
• Direct reading center distance measurements in Inch or • Supplied with fitted carrying case.
Metric. • The Digimatic Calipers provide digital readout to
• Hole diameter should be larger than .06" (1.5mm) but .0005"/0.01mm for error-free reading. These Models
smaller than .4" (10mm). also incorporate Mitutoyo‘s exclusive Absolute Encoder.
Specifications
Digimatic Offset Centerline Calipers with Absolute Encoder
Inch/Metric (with SPC output)
LCD
Order No. Range Resolution Accuracy Remarks
573-205-10 .4"–6" .0005" ±.0015"
10.16-150mm 0.01mm without Depth Bar
573-206-10 .4"–8" .0005" ±.0015"
10.16-200mm 0.01mm without Depth Bar
For SPC output order connecting cable 959149 (1m) or 959150 (2m). Replacement Battery: 541980 (1pc), 541980-10 (10pcs/SET).
O-27
O-28 (2003) full size 12/8/03 10:12 PM Page 1
CALIPERS
.138"
in/mm
ON
Point Type
1.57"
Absolute Encoder
Digimatic Caliper
.39"
.012"
.012" Point Type
20° 573-221-10
9.09"
30°
.138"
573-225-10 in/mm
ON
Absolute Encoder
1.57"
Digimatic Caliper
.39"
LUT .08"
SO E .08"
Extended Point Type
AB
573-225-10
Y
OG
EC
H N OL
T
Shallow planes and similar dimensions can be accurately making many previously difficult outside measurements
measured with MITUTOYO Point and Extended Point far easier to obtain.
Calipers. Digimatic models now feature Mitutoyo‘s exclusive
The narrow tip jaws fit into very small grooves and tracks, Absolute encoder.
Features
• Comes with inside jaws.
• Measures depth and step dimensions.
• Includes carrying case.
Specifications
Digimatic Point Calipers with Absolute Encoder
Inch/Metric (with SPC output)
LCD
Order No. Range Resolution Accuracy
573-221-10 0–6" .0005" ±.001"
0–150mm 0.01mm
573-225-10 0–6" .0005" ±.001"
0–150mm 0.01mm
*For SPC output order Connecting Cable 959149 (1m) or 959150 (2m). All models listed above operate on a single SR-44 (541980)
battery which lasts approximately 3.5 years with normal use.
Replacement Battery: 541980 (1pc), 541980-10 (10 pcs/SET)
O-28
O-29 (2003) full size 12/8/03 10:12 PM Page 1
CALIPERS
573-291-10
Low Pressure
Digimatic Caliper
536-252
Low Pressure
Dial Caliper
IN/MM
DATA/HOLD
AB
pointer is between the two index OFF ON/ZERO
Y
OG
lines. EC
1.57"
H N OL
T
Features
• Designed specifically to measure resilient workpieces. • The jaw on the blade travels .012"/0.3mm.
Contact pressure: .49N to .98N (50 to 100gf) • Digimatic caliper provides direct digital reading to
• Due to the low measuring force these calipers are ideal .0005"/0.01mm on an LCD screen. This model also
for elastic workpieces such as plastic parts that stan- features an Absolute Encoder.
dard calipers cannot measure. • Digimatic caliper can be linked to the SPC System.
• Easy fine feeding with the thumb roller.
Specifications
Digimatic Low Pressure Caliper with Absolute Encoder
Inch/Metric (with SPC output)
LCD
Order No. Range Resolution Accuracy Remarks
573-291-10 0–7" .0005" ±.002"
0–180mm 0.01mm without Depth Bar
Measuring Force: .49N to .98N
For SPC output order connecting cable 959149 (1m) or 959150 (2m). Replacement Battery: 541980 (1pc), 541980-10 (10 pcs/SET)
O-29
O-30 (2003) full size 12/8/03 10:13 PM Page 1
CALIPERS
Inch Fractional and Decimal Readings Inch Decimal Reading Only (for Inside and
This vernier caliper has two scales which enable read- Outside Jaws)
ings to a fraction of an inch as in the case of 1/128" The vernier reads inside and outside dimensions with
graduated vernier (upper scale), or in decimals as in the the same jaws. Inside measurements are taken by the
case of 1/1000" graduated vernier (lower scale). specially designed jaw construction. Because of the
Each division on the fractional main scale represents .300" inside jaw thickness, the vernier is placed .300" off
1/16th of an inch. The vernier further subdivides each from zero point. Taking this difference into account, the
division on the main scale to read 1/128 of an inch. final inside reading is .300" greater than the outside
reading.
Each division of the decimal main scale represents one
fortieth of an inch or .025". Each fourth line marked by 1 Like the Vernier Caliper in the preceding column, the
represents .100", the line marked 2 represents .200", vernier above also reads to 1/1000 of an inch. In this
and so forth. The vernier consists of 25 equal divisions case, however, each division on the main scale repre-
which further subdivides each division on the main sents one-twentieth of an inch or .050". This means each
scale to .001". division on the main scale is twice as wide as the previ-
ous example, and therefore, the vernier must span twice
1. 1/128" graduated vernier (upper scale) the length to read to 1/1000 of an inch.
Readings on the main scale................................16/16"
Vernier scale reading ...........................................3/128" 1. Inside vernier reading (upper scale)
Final reading...........................16/16 + 3/128 = 151/128" Reading on the main scale.................................1.200"
Vernier line coinciding with main scale line........ .018"
2. 1/1000" graduated vernier (lower scale) Final reading ....................................................1.218"
Main scale reading ............................................1.375"
Vernier scale reading......................................... .023" 2. Outside vernier reading (lower scale)
Final reading ....................................................1.398" Reading on the main scale................................. .900"
Vernier line coinciding with main scale line........ .018"
Final reading..................................................... .918"
O-30
O-31 (2003) full size 12/8/03 10:14 PM Page 1
CALIPERS
Plain and Basic vernier caliper with locking screw atop With fine-adjustment for precise measurement.
the moving slider.
The jaws move only when spring loaded thumb clamp Outside jaws are carbide faced for measurements of
is depressed. abrasive products.
O-31
O-32 (2003) full size 12/8/03 10:15 PM Page 1
CALIPERS
531-129
532-106
530-312
Features
• The finest of vernier calipers for accurate work, with • Models available with a fine-adjustment carriage to
Mitutoyo’s exclusive “Quardi” 4-way measuring feature. fine-feed the slider.
• Can measure OD, ID, depth and steps.
Specifications
Vernier Caliper (with Fine Adjustment)
Inch
Range Vernier Resolution
Order No. Lower scale Upper scale Lower scale Upper scale Accuracy
532-104 0–5" 0–5" .001" 1/128" ±.0015"
532-105 0–7" 0–7" .001" 1/128" ±.0015
532-106 0–11" 0–11" .001" 1/128" ±.0015"
Inch/Metric
Range Vernier Resolution
Order No. Lower scale Upper scale Lower scale Upper scale Accuracy
532-119 0–130mm 0–5" 0.02mm .001" ±0.03mm
532-120 0–180mm 0–7" 0.02mm .001" ±0.03mm
532-121 0–280mm 0–11" 0.02mm .001" ±0.04mm
O-32
O-33 (2003) full size 12/8/03 10:16 PM Page 1
CALIPERS
A
Dimensions (Fine Adjustment Type)
E
Order No. A B C D E F G t❈
C
532-104
9.02" 3.05" .65" 1.58"
532-119
3.0" 1.23" .63" .118"
532-105
G
F
11.34" 3.58" .81" 1.97"
532-120
B
532-106
15.87" 4.39" .87" 2.52" 3.66" 1.5" .79" .150"
532-121
D
❈ t : Jaw Thickness
Vernier Calipers
Inch
Range Vernier Resolution
Order No. Lower scale Upper scale Lower scale Upper scale Accuracy Remarks
530-105 0–6" 0–6" .001" 1/128" ±.0015"
530-314 0–6" 0–6" .001" 1/128" ±.0015" with OD
Carbide Jaw
530-116 0–8" 0–8" .001" 1/128" ±.0015"
Inch/Metric
Range Vernier Resolution
Order No. Lower scale Upper scale Lower scale Upper scale Accuracy Remarks
530-104 0–150mm 0–6" 0.05mm 1/128" ±0.05mm
530-312 0–150mm 0–6" 0.02mm .001" ±0.03mm
530-118 0–200mm 0–8" 0.02mm .001" ±0.03mm
530-115 0–300mm 0–12" 0.05mm 1/128" ±0.08mm
530-119 0–300mm 0–12" 0.02mm .001" ±0.04mm
530-101 0–150mm — 0.05mm — ±0.05mm
530-108 0–200mm — 0.05mm — ±0.05mm
530-321 0–200mm — 0.05mm — ±0.05mm with OD
Carbide Jaw
530-109 0–300mm — 0.05mm — ±0.08mm
530-322 0–300mm — 0.05mm — ±0.08mm with OD
Carbide Jaw
530-501 0–600mm — 0.05mm — ±0.10mm
O-33
O-34 (2003) full size 12/8/03 10:17 PM Page 1
CALIPERS
C
531-107 9.02" 3.05" .65" 1.58"
531-128
2.11" 1.22" .63"
531-114
G
F
531-108 11.34" 3.58" .81" 1.97"
B
531-129
D
Dimensions (Vernier Calipers)
Order No. A B C D E F G
530-105
530-314
530-104 9.02" 3.05" .65" 1.58" A
530-312
530-101 2.13" 1.18" .63" E
530-116
C
530-118
11.34" 3.58" .81" 1.97"
530-108
G
F
530-321
B
530-115
530-119
15.87" 4.39" .87" 2.52" 2.64" 1.42" .79"
D
530-109
530-322
530-501 30.71" 6.38" 1.5" 3.54" 3.54" 1.97" .98"
O-34
O-35 (2003) full size 12/15/03 10:16 AM Page 1
CALIPERS
DIAMOND MASTER
522-600
VERNIER CALIPER
A
Features
E
• The main and vernier scales are flush-fitted
C
G
F
of the main scale.
B
Vernier
Dimensions
graduation
3
t❈
30
Order No. A B C D E F G
2
Mainscale
Main scale 522-601
graduation
graduation 522-602 9.02" 3.05" .67" 1.60" 2.11" 1.18" .59" .138"
522-600
❈ t : Jaw Thickness
Diamond master(Parallel Scale Faces)
Diamond-shaped
cross section of
main scale
Specifications
Inch/Metric
Range Vernier Resolution
Order No. Lower scale Upper scale Lower scale Upper scale Accuracy Remarks
522-601 0–150mm 0–6" 0.05mm 1/128" ±0.05mm
522-602 0–150mm 0–6" 0.02mm .001" ±0.03mm
O-35
O-36 (2003) full size 12/8/03 10:19 PM Page 1
CALIPERS
Vernier Calipers
Series 160, 534
160-124
534-107
534-117
Features
• With a fine-adjustment carriage to fine-feed the slider. • The jaws have round measuring faces for accurate ID
• Long jaws for measuring hard-to-reach portions. measurement.
• No depth measuring bar.
Specifications
Long Jaw Vernier Calipers with Fine Adjustment.
Inch
Range Range Vernier Resolution
Order No. Outside Inside Outside Inside Accuracy
534-117 0–12" .3–12" .001" .001" ±.002"
534-118 0–20" .8–20" .001" .001" ±.003"
534-119 0–30" .8–30" .001" .001" ±.004"
534-120 0–40" .8–40" .001" .001" ±.004"
Inch/Metric
Range Vernier Resolution
Order No. Lower scale Upper scale Lower scale Upper scale Accuracy
534-105 0–300mm 0–12" 0.02mm .001" ±0.04mm
534-106 0–500mm 0–20" 0.02mm .001" ±0.06mm
534-107 0–750mm 0–30" 0.02mm .001" ±0.08mm
534-108 0–1000mm 0–40" 0.02mm .001" ±0.10mm
O-36
O-37 (2003) full size 12/8/03 10:19 PM Page 1
CALIPERS
Dimensions
Order No. A B D E F G H I t❈ A
534-105 .394" E
17.52" 4.33" 3.55" 4.06" 1.5" .79" .47" .150"
534-117 .3"
534-106 .787"
26.85" 8.86" 4.41" 2.01" .98" .236"
G
F
534-118 .8"
534-107 .787"
39.17" 7.87" .73"
534-119 .8"
9.14" 5.91" 2.46" 1.26" .315"
534-108 .787"
48.43"
B
534-120 .8"
D
160-124 .3"
160-125 17.52" 3.74" 2.95" 4.06" 1.5" .79" .47" .5" .150"
160-127 .394"
H
160-116 .5"
160-119 24.88" .5"
I
160-128 .787"
4.92" 3.94" 4.41" 2.01" .98" .71" .236"
160-102 .5"
160-103 30.71" .5"
160-101 .787"
160-105 1.0"
160-106 48.82" 6.77" 5.51" 5.91" .95" 1.0"
160-104 .787"
2.46" 1.26" .315"
160-111 1.0"
160-112 70.87" 8.35" 7.09" 6.7" 1.18" 1.0"
160-110 .787"
❈ t ; Jaw Thickness
O-37
O-38 (2003) full size 12/8/03 10:20 PM Page 1
CALIPERS
050001
Application for 4", 6" and 8" Vernier,
Dial and Digimatic Calipers,
050018 requiring dimensions
Application for 12" over .375".
Vernier, Dial and
Digimatic Calipers
requiring dimensions
over .5".
Pairs of conical probes are specially less than .375" when the caliper is quite durable for the required mea-
designed for Digimatic, Dial and closed with the attachment installed. surements.
Vernier calipers to quickly measure The centerline distance is read The 60° conical probe snugly fits into
centerline distances. directly off the caliper without a con- the holes, and takes guesswork away
Due to the fact that the smaller version factor. from center distance measurements.
attachment is .375" in diameter, and Each probe has two small holding
that the conical points are .375" bolts and the attachment is supplied
apart when closed, the centerline with an Allen wrench. The probes
gages do not measure distances are black oxide finished, and are
Dimensions
L A B C
050001 .375" 2.187" .141"
050018 .500" 2.75" .154"
Specifications
Center Line Gage
Order No. Description
050001 For 4, 6 and 8" Calipers
050018 For 12" Calipers
O-38
O-39 (2003) full size 12/8/03 10:20 PM Page 1
CALIPERS
050083
Features
• For 4", 6", 8" and 12" MITUTOYO Vernier, Dial and
Digimatic Calipers.
• Choice of 3" or 4" base length for 6" and 8" models.
• Finely ground base surface and secure locking clamp.
B Application
Example
All measurements in inches.
O-39
P-01 (2003) full size 12/11/03 3:45 PM Page 1
Height Gages
Selection Guide - Scriber and Clamps P-2
HEIGHT GAGES
(T)
(T)
(H)
(H)
All Scribers - Carbide-tipped.
Specifications
Clamp Scriber Scriber Dimensions
Order No. Order No. (L x H x W x T) Product No. Description
520-149 Vernier type: 300mm
901384 900167 5.6" x .9" x .35" x .35"
508-211 Vernier type: 18"/450mm
905006 900282 7.2" x 1.16" x .35" x .4" 520-150 Vernier type: 600mm
574-210A Digimatic type: 24"/600mm
905007 900258 2.4" x 1.2" x .25" x .5"
574-211A Digimatic type: 18"/450mm
192-666 Digimatic type: 12"/300mm
192-667 Digimatic type: 18"/450mm
07GZA032 905201 5.9" x 1.77" x .25" x .5" 192-668 Digimatic type: 24"/600mm
192-669 Digimatic type: 40"/1000mm
570-236 Digimatic type: 40"/1000mm
192-130 Digital type: 300mm
192-131 Digital type: 450mm
07GZA002 07GZA000 3.15" x 1.26" x .35" x .35" 192-132 Digital type: 600mm
192-133 Digital type: 1000mm
514-105 Vernier type: 18"/450mm
901385 900172 5.3" x 1.0" x .25" x .5" 508-212 Vernier type: 18”
506-202 Vernier type: 6"/150mm
506-205 Vernier type: 10"/250mm
509-313 Dial type: 6"
901338 900173 1.9" x 1.0" x .25" x .5"
509-314 Dial type: 10"
509-301 Dial type: 150mm
570-212 Digimatic type: 8"/200mm
509-302 Dial type: 250mm
192-140 Digital type: 12"
192-141 Digital type: 18"
192-142 Digital type: 24"
192-143 Digital type: 40"
192-616 Digimatic type: 12"/300mm
192-617 Digimatic type: 18"/450mm
192-618 Digimatic type: 24"/600mm
07GZA032 900258 2.4" x 1.2" x .25" x .5"
192-619 Digimatic type: 40"/1000mm
570-233 Digimatic type: 12"/300mm
570-234 Digimatic type: 18"/450mm
570-235 Digimatic type: 24"/600mm
574-212-1A Digimatic type: 12"/300mm
574-211-1A Digimatic type: 18"/450mm
574-210-1A Digimatic type: 24"/600mm
192-150 Digital type: 12"
192-151 Digital type: 18"
192-152 Digital type: 24"
192-153 Digital type: 40"
192-630 Digimatic type: 12"/300mm
901385 900258 2.4" x 1.2" x .25" x .5"
192-631 Digimatic type: 18"/450mm
192-632 Digimatic type: 24"/600mm
192-633 Digimatic type: 40"/1000mm
570-240 Digimatic type: 12"/300mm
570-241 Digimatic type: 18"/450mm
570-242 Digimatic type: 24"/600mm
192-670 Digimatic type: 12"/300mm
192-671 Digimatic type: 18"/450mm
901385 905201 5.9" x 1.77" x .25" x .5" 192-672 Digimatic type: 24"/600mm
192-673 Digimatic type: 40"/1000mm
570-243 Digimatic type: 40"/1000mm
P-2
P-03 (2003) full size 12/8/03 10:34 PM Page 1
Specifications
Order No. 518-321-20A (120V with English manual)
Measuring Range (stroke) 0-38" (34")/0-972mm(600mm)
Resolution (selectable) .000001"/.00001"/.0001"/.001"/
0.0001mm/0.001mm/0.01mm/0.1mm Dimensions
Accuracy Measuring accuracy .00008 + (.00004 x L/24)”/(2 + L**/600)µm
at 20°C Repeatability (2σ) Plane: .00002"/0.5µm Bore: .00004"/1µm
Perpendicularity .00025"/6µm
Straightness .0002"/4µm
Drive Method Manual/Motor (.2"-1.57", 7 steps)
10.31" (2.62)
Measuring Force 1N
Balancing Method Counter balance
Main Unit Floating Method Full/semi-floating with air
Air Source Built-in air compressor
LCD Graphic LCD (320 x 240 dot, with backlight)
Language for Display English/German/French/Spanish/Italian/Japanese
Number of Programs 50 (max.)
Number of Datas 60,000 (max.)
Power Supply AC Adapter/Battery (Ni-MH)
Power Consumption 43VA
Operation Time Approx. 5 hours
Standard Accessories ø5 Eccentric probe (12AAC080)
Probe diameter calibration block (12AAA715)
Battery (12AAA786)
AC adapter (357651)
Clear Cover (223587)
Conveying handle (510434)
Mass 52.8 lbs/24kg
*L=Measuring length (inch)
**L=Measuring length (mm)
P-3
P-04 (2003) full size 12/8/03 10:34 PM Page 1
SYSTEM DIAGRAM
P-4
P-05 (2003) full size 12/8/03 10:35 PM Page 1
Features
• Zero-setting
• Presetting count direction
• SPC Data output
• Data hold
• Display: LCD 7 digits, height of LCD characters .55”
• GO/NG judgement mode
• Inch/Metric
• Easy movement using optional grip
Specifications
Linear Height Lite 518-203
Inch/Metric (with SPC Output)
Order No. 518-201 518-203
Measuring Range 14” (350mm) 24” (600mm)
.00005”/.0001”/.0005”
Resolution
(0.001mm/0.005mm)
Measuring
±.0004”/±10µm
Accuracy Accuracy
At 20°C Repeatability (2σ) .00012”/3µm
Perpendicularity .0008”/±20µm
Driving Method Manual Operation
Measuring Force 1.6±0.5N
Battery (3pcs. AA Alkaline)/
Power Supply
AC Adapter (Optional)
1000 hrs (200 hrs for GO/NG
Battery Life
judgement mode
ø5 stepped probe (05H2A148)
Standard Accessories
3 pcs. AA Alkaline batteries
Mass 40 lbs 43.5 lbs
Dimensions
Order No. H
518-201 30” (761mm)
518-203 39.8” (1011mm) Optional
Grip
P-5
P-06 (2003) full size 12/8/03 10:36 PM Page 1
Specifications – Inch/Metric
Order No. 518-221 518-223
Range 0 - 14" 0 - 24"
(0 - 350mm) (0 - 600mm)
Resolution .00005", .0001", .0002",
0.001mm, 0.005mm
Accuracy ± (2.8+5L/ 1000)µm
Repeatability 2σ 1.8µm 518-223
Display LCD
Functions Zero setting, -/+ switching, Presetting,
Data hold, Probe tip diameter compensation,
inch/mm conversion (Inch/Metric model only),
Data output
Perpendicularity 0.008mm 0.013mm
Measuring force 1.6 ± 0.5N
Data output SPC, RS-232C
Power supply AC adapter (optional accessory) / Battery (LR6x4)
Battery Life Approx. 800 Hrs. (when backlight is not used)
Approx. 260 Hrs. (When backlight is used
in the power saving mode)
Approx. 6 Hrs. (When backlight is used in
the Full-Time Turn-On mode)
Standard ø5mm stepped probe (05HZA148)
Accessories 4 pcs. AA Alkaline Batteries (LR6)
Users Manual 99MAF017B
Dimensions 8.27 x 13.78 x 30.39" 8.27 x 13.78 x 40.24"
(W x D x H) (210 x 350 x 772mm) (210 x 350 x 1022mm)
Mass 22kg 27kg
P-6
P-07 (2003) full size 12/8/03 10:37 PM Page 1
Optional Accessories
Order No. Description
958261 ø2mm ball probe
957262 ø3mm ball probe
957263 ø4mm ball probe
12AAA788 ø4mm ball offset probe
12AAA789 ø6mm ball offset probe
12AAA715 Setting block for ball probe
957264 ø14mm disk probe
957265 ø20mm disk probe
226116 Test indicator (ø6mm stem) adapter
12AAA793 Probe extension holder (199mm)
12AAA792 Dial indicator (ø8mm stem) holder
12AAA837 Dial indicator (ø3/8" stem) holder
954232 Depth probe
05HZA173 Scriber
05HZA143 9 x 9mm adapter for dial test indicator
05HZA144 .25 x .5" adapter for dial test indicator
05GZA033 Clamp for 05HZA143
901385 Clamp for 05HZA144 (For .25 x .5")
936937 SPC cable for Digimatic data entry (1m)
965014 SPC cable for Digimatic data entry (2m)
526688A AC Adapter (120V)
System Diagram
P-7
P-08 (2003) full size 12/8/03 10:38 PM Page 1
HEIGHT GAGES
Heightmatic
Series 574
HIGH PRECISION DIGITAL HEIGHT GAGE
The MITUTOYO HEIGHTMATIC is a new high precision
digital height gage designed for applications needing
extremely accurate measurements. The bi-directional
touch signal probe is adopted for improved efficiency
and reliability of measurement.
574-007
Features
• .0001"/0.001mm resolution.
• ±.0002"/±0.004mm accuracy.
• Functions:
Zero-setting, Presetting, ABS/INC measurement mode
switching, Data hold, Count direction switching,
inch/mm conversion, Data output. 574-212-1A
• Supplied with the bi-directional touch signal probe. The
stylus tip ball diameter is automatically compensated
for measurement.
• Fine feed wheel for the slider is provided on the base
for easy operation.
• Provided with a data output port for connection with
the SPC system.
Order No. A B C
.39" (10)
C
574-211-1A 28.50" .5" .25" .51" (13) 1.79" (45.5 ) 3.58" (91) 1.61" (41)
574-210-1A 34.41" .5" .25"
5.12" (130)
1.36" (35.4)
1.20" (30.5)
Ø.12" (Ø3 ball)
Ø1.65"
(Ø42)
Optional Accessories
A
B
Order No. Remarks
.24" (6)
900258 Scriber
2.05" (52) .24" 1.38" (35)
905691 SPC Connecting Cable (1m) .98" (25) (6)
4.49" (114)
905692 SPC Connecting Cable (2m)
145250 ø1mm Contact Point
145251 ø2mm Contact Point
2.76" (70)
Heightmatic (mm)
Inch/Metric
Order No. 574-212-1A 574-211-1A 574-210-1A
Measuring Range 0-12"/0–300mm 0-18"/0-450mm 0-24"/0-600mm
Resolution .0001"/0.001mm
Accuracy ±.0002"
Repeatability .0001"/0.001mm
Quantizing error ±1 count
Response Speed (MAX) 19/69"/s (500mm/s)
Display LCD, 6 digit and minus sign (-)
Power Supply AC Adapter (9V 500mA)
Mass 29.92 lbs. 32.78 lbs. 35.64 lbs.
Standard Accessories AC Adapter (525694A)
Touch signal probe (574-007)
Scriber clamp (901385)
P-8
P-09 (2003) full size 12/8/03 10:38 PM Page 1
HEIGHT GAGES
A
F
Dimensions
HDS
Order No. A B C D E F G
HOME LIGHTS
B
HDS
.25
C
E G
Specifications
HDS Digimatic Height Gages
Inch/Metric
Order No. 570-244 570-248
Measuring Range 0–8"/200mm 0–40"/1000mm
Resolution .0005"/ 0.01mm
Accuracy ±.002" ±.003"
Repeatability .0005" (0.01mm)
Power Supply Silver oxide cell (SR-44) 1pc 541980
Data Output Digimatic code output (SPC output)
Mass 2.93 lbs 37.0 lbs
Standard Scriber 900173 Scriber 905201
Accessories Scriber Clamp Scriber Clamp 901385
901338
SR-44 battery 1pc. SR-44 battery 1pc.
For SPC output order connecting cable 905338 (1m) 0r 905409 (2m). Replacement Battery: 541980 (1 pc.), 541980-10 (10 pcs./SET)
P-9
P-10 (2003) full size 12/8/03 10:39 PM Page 1
HEIGHT GAGES
Dimensions
Order No. L A B C D
570-312 19.96" 6.30" 4.80" 2.32" 2.86"
570-313 26.06" 7.13" 5.59" 2.32" 2.92"
570-314 31.97" 7.13" 5.59" 2.32" 2.92"
570-302 19.96" 6.30" 4.80" 2.32" 2.86"
570-304 31.97" 7.13" 5.59" 2.32" 2.92"
Specifications
HDS Digimatic Height Gages
Inch/Metric
Order No. 570-312*1 570-313*1 570-314*1 570-302*2 570-304*2
Measuring Range 0–12"/300mm 0–18"/450mm 0–24"/600mm 0–300mm 0–600mm
Resolution .0005"/ 0.01mm 0.01mm
Accuracy ±.0015" ±.002" ±0.03mm ±0.05mm
Repeatability .0005" (0.01mm) 0.01mm
Power Supply Silver oxide cell (SR-44) 1pc 541980
Data Output Digimatic code output (SPC output)*
Mass 10.12 lbs 12.98 lbs 14.08 lbs 10.12 lbs 14.08 lbs
Standard Scriber 900258 Scriber 07GZA000
Accessories Scriber Clamp 901385 Scriber Clamp 05GZA033
SR-44 battery 1pc. SR-44 battery 1pc.
*For SPC output order connecting cable 905338 (1m) 0r 905409 (2m). Replacement Battery: 541980 (1 pc.), 541980-10 (10 pcs./SET)
*1 Dimensions for 570-312, 570-313 & 570-314
*2 Dimensions for 570-302 & 570-304
P-10
P-11 (2003) full size 12/8/03 10:41 PM Page 1
HEIGHT GAGES
Features
• Easy-to-use design.
• Double-column structure ensures high measuring
accuracy.
• Display: LCD Height .394", 6 digits and a minus
sign (-).
• Functions include: Zero/ABS setting (ABS and INC
modes), Preset Value Memory (ABS mode), Data hold,
Presetting (ABS and INC modes), ± Counting direction
changeover, Inch/mm conversion, Coarse/Fine Feed
switching, Over-speed alarm, Low battery alarm.
• Carbide-tipped scriber.
• Dust/water protection level conforms to IP-40
standards.
192-630
Specifications
Digimatic Height Gages D
Inch/Metric
Order No. 192-630 192-631 192-632 192-633 C
Measuring Range 0–12" 0–18" 0–24" 0–40"
0–300mm 0–450mm 0–600mm 0–1000mm
Resolution .0005"/0.01mm
Accuracy (20°C) ±.001" ±.002" ±.003" B
3.27"
P-11
P-12 (2003) full size 12/8/03 10:42 PM Page 1
HEIGHT GAGES
Features
• Two measuring modes, ABS (absolute) and INC
(incremental), for increased inspection efficiency.
• Rigid construction ensures repeatable measurements.
192-670
• Bi-directional touch signal probe for improved efficiency
with option
and reliability of measurement. (192-008)
Touch Probe
• Display: LCD, Height .394", 6 digits and a minus sign (-).
• Functions include: Zero/ABS setting (ABS and INC
192-008
modes), Origin restoration, Presetting (ABS and INC
modes), Preset value memory (ABS mode), Data hold,
Inch/mm conversion, Coarse/Fine Feed switching,
Counting direction, Error alarm, Low battery alarm.
• Provided with a data output port for connection with the
SPC system.
• Standard long scriber (5.90") carbide-tipped.
CONTROL PANEL FEATURES
On/Off switch Mode Switch (Switches
Inch/Metric switch between preset and touch
Zero/ABS switch probe dia. compensation).
Data/Hold switch Counting Direction switch
Touch Probe
Order No. 192-008
Measuring Direction Two-Direction Dimensions
Order No. A B C D E F G H
Over Travel .06" (1.5mm)
192-670 3.94" 20.09" 1.18" 2.76" .79" 1.50" 1.89" 5.87"
Repeatability .00008" (2µm)
192-671 4.72" 25.55" 1.18" 2.76" .79" 1.50" 2.13" 7.09"
Measuring Force 0.4N 192-672 4.72" 31.57" 1.18" 2.76" .79" 1.50" 2.13" 7.09"
Contact Point .12" (ø3mm) carbide ball 192-673 5.91" 48.35" 1.38" 8.39" .79" 1.50" 2.56" 9.84"
Specifications
Digimatic Height Gages
Inch/Metric D
P-12
P-13 (2003) full size 12/8/03 10:43 PM Page 1
HEIGHT GAGES
Features
• Easy and error-free reading with both up and down
digital counters as well as a dial.
• The counters and dial can be zeroset at any scriber
position.
• Provided with a feed wheel for easy coarse feeding.
• Carbide-tipped scriber.
192-152
192-150
192-150
12"
Specifications
Digital Counter Type Height Gage
Inch
Dial Digital Counter Mass Standard
Order No. Range Graduation Graduation Accuracy (lbs) Accessories
192-150 0–12" .001" .1" (Dual Reading) ±.0015" 9.26
192-151 0–18" .001" .1" (Dual Reading) ±.002" 20.28 Scriber (900258)
192-152 0–24" .001" .1" (Dual Reading) ±.002" 21.60 Scriber Clamp (901385)
192-153 0–40" .001" .1" (Dual Reading) ±.003" 37.5
Metric
Dial Digital Counter Mass Standard
Order No. Range Graduation Graduation Accuracy (lbs) Accessories
192-130 0–300mm 0.01mm 1.0mm (Dual Reading) ±0.03mm 9.26
192-131 0–450mm 0.01mm 1.0mm (Dual Reading) ±0.05mm 20.28 Scriber (07GZA000)
192-132 0–600mm 0.01mm 1.0mm (Dual Reading) ±0.05mm 21.60 Scriber Clamp (07GZA002)
192-133 0–1000mm 0.01mm 1.0mm (Dual Reading) ±0.07mm 37.5
P-13
P-14 (2003) full size 12/8/03 10:46 PM Page 1
HEIGHT GAGES
I A
Dimensions
Order No. A B C D E F G H I
.47"
Order No. A B C D E F G H I
192-130 1.18" .59" .35" 3.58" 1.17" 5.31" 18.50" 1.19" 2.48"
E C
192-131 1.26" .79" .35" 4.72" 1.38" 7.08" 25.51" 1.19" 2.75"
192-132 1.26" .79" .35" 4.72" 1.38" 7.08" 31.42" 1.19" 2.75"
192-133 1.57" .79" .35" 5.90" 1.38" 9.84" 48.03" 1.43" 8.39"
F D
P-14
P-15 (2003) full size 12/8/03 10:46 PM Page 1
HEIGHT GAGES
.78"
.15"
Dimensions
Range A B C
6"/150mm 1.77" 3.36" 11.06"
10"/250mm 2.39" 3.95" 15.00"
509-313
.31"
.001"
.25"
1.0"
A B
Specifications
Dial Height Gages
Inch
Dial Reading Mass Standard
Order No. Range Graduation Range/rev Accuracy (lbs) Accessories
509-313 0–6" .001" .10" ±.001" 1.76 Scriber (900173)
509-314 0–10" .001" .10" ±.0015" 2.64 Scriber Clamp (901338)
Metric Model
Dial Reading Mass Standard
Order No. Range Graduation Range/rev Accuracy (lbs) Accessories
509-301 0–150mm 0.02mm 2.0mm ±0.03mm 1.76 Scriber (900173)
509-302 0–250mm 0.02mm 2.0mm ±0.04mm 2.64 Scriber Clamp (901338)
P-15
P-16 (2003) full size 12/8/03 10:47 PM Page 1
HEIGHT GAGES
Features
• Beam and measuring slide made of stainless steel.
• Base and all measuring surfaces are hardened,
ground and microlapped for accuracy.
• Clear, crisp black graduations on a satin-chrome finish
for easy reading and each 0.1" is numbered.
• Right hand type for easy use.
• Raised sliding surfaces on main scale prevent
defacement and wear of graduations.
• Fine adjustment for easy setting.
• Scriber clamp also accepts Test Indicator Bars
(No. 900306) readily.
• Carbide tipped offset scriber, No. 900173.
.78"
.15"
C 506-202
Dimensions
Range A B C
6"/150mm 1.77" 3.36" 11.06"
10"/250mm 2.39" 3.95" 15.00"
.31"
.25"
1.0"
A B
Specifications
Vernier Height Gages
Inch/Metric
Vernier Resolution Mass Standard
Order No. Range Inch Metric Accuracy (lbs.) Accessories
506-202 0–6" (0–150mm) .001" 0.02mm ±.001" 1.76 Scriber (900173)
506-205 0–10" (0–250mm) .001" 0.02mm ±.0015" 2.64 Scriber Clamp (901338)
P-16
P-17 (2003) full size 12/8/03 10:48 PM Page 1
HEIGHT GAGES
Specifications
Depth Gage Attachment
Inch
Order No. Description Remarks
900878 For Inch Model Height Gages Shank Length: 3.94" (.25" x .50" Shank) 900878
900764 For Metric Model Height Gages Shank Length: 3.94" (.35" x .35" Shank)
Contact Sensor
900872
Features
• The Contact Sensor eliminates errors caused by
jacking-up the height gage too much while taking
measurements. When the scriber of a height gage
touches a conductive workpiece, an indicator will light
up to indicate that measurement can be taken, which 900872
will result in consistent height measurements.
• Incorporates magnets for easy attachment.
• Power supply: SR-44, 2 pcs. (541980)
• Measurements should be taken on a granite surface
plate or other non-conductive surface.
Contact Sensor
Order No. Description Remarks
900872 Contact Sensor for Power Supply: SR-44 (541980)
Conductive Workpieces
Center Master
900581
Features
• Allows quick measurement of center-to-center distance
between holes. 900581
• Measurable hole diameters: .04"–1.49"
P-17
Q-01 (2003) full size 12/11/03 3:45 PM Page 1
Depth Gages
Digimatic Depth Gages w/Absolute Encoder - Series 547 Q-2
DEPTH GAGES
547-217
LUT
SO E
AB
Y
OG
EC
H N OL
T
Optional Accessories
Base Only (3/8" Dia. Hole)
ø2.38"(ø60.5)
Inch/ mm +/-
Part No. Length Remark
902164 2.5" 547-217, 7217, 7237, 547-257
4.13"(105)
ZERO/ ABS ON/ OFF
902165 4" 547-218, 7218, 7238, 547-258 PRESET TOL..
(16.5)
.65"
ø.63"(ø16)
Features
(18.4)
.72"
(10.8)
• Digital readout for error-free reading.
.43"
• Uses IDC Type Digimatic Indicator with exclusive
Absolute Encoder. 4"(101.6)
.63"(16)
• Face rotates 330° for use at different angles.
Unit: Inch (mm)
• Provided with a data output port for connection with
SPC system.
• Power supply: Silver oxide cell (SR-44 1 pc). Standard Accessories
• Battery life: 5,000 hours • Extension rods (4 pcs.): .5", 1", 2", 4"
• Provided GO/NG judgement function and the indication • Interchangeable stylus (1 pc.)
of the judgement result. • Allen wrench (1 pc.)
• Contact point = 4-48 UNF • Battery SR-44 (1 pc. No. 541980)
Specifications
Digimatic Depth Gages with Absolute Encoder (with SPC output)
Inch/Metric
LCD Spindle Base Measuring Base
Order No. Range Resolution Stroke Length Force Accuracy Flatness Remarks
547-217 0–8" .0005" .5" 2.5" 1.5N .001" .0002" with Extension
0–200mm 0.01mm or less Rods (4 pcs)
547-218 0–8" .0005" .5" 4" 1.5N .001" .0002" with Extension
0–200mm 0.01mm or less Rods (4 pcs)
547-257 0–8" .00005" .5" 2.5" 1.2N .00012" .00008" with Extension
0–200mm 0.001mm or less Rods (4 pcs)
547-258 0–8" .00005" .5" 4" 1.2N .00012" .00008" with Extension
0–200mm 0.001mm or less Rods (4 pcs)
For SPC output order Connecting Cable 905338 (1m) or 905409 (2m).
Q-2
Q-03 (2003) full size 12/8/03 7:09 PM Page 1
DEPTH GAGES
0
10 90
20 80
30 8
9 0 1
2
70
3.88"
7 3
6 5 4
7218 40
50
60 .63"
2.54"
.71"
.63"
(2.5" or 4.0")
Features
• The Dial Indicator has a precision-ground, hard-chrome- • Spindle lifting lever for raising and lowering and spindle
plated stem with standard AGD 3/8" diameter. Contact is maintained under spring pressure.
point is hardened, ground and chrome-plated steel. • Bottom surface of the base is hardened, ground and
Spindle rack, pinions and pivots are hardened stainless lapped for highest degree of flatness.
steel to insure long wear and continuing accuracy. Bezel
is cleanly knurled and smoothly adjustable with a • Complete with fitted carrying case.
clamping screw for positive settings. Accuracy of the • The Dial Indicator is attached to the base by a clamping
Dial Indicator exceeds Federal Specifications. screw and readily interchangeable with any other stan-
• Rods are available in 1", 2" and dard AGD dial indicator.
4" lengths and may be connected for depths up to 8".
(1" on Dial Indicator + 1" rod + 2" rod + 4"
rod = 8".) 10, 20, 30 and 100mm rods for Metric model.
Specifications
Dial Depth Gages STANDARD ACCESSORIES
Inch Inch
Dial Spindle Order No. Description
Order No. Range Resolution Stroke Remarks
301655 1" Rod
7217 0–8" .001" 1.0" Measuring Force: 2.0N or less 301657 2" Rod
Base Length: 2.5" 301659 4" Rod
7218 0–8" .001" 1.0" Measuring Force: 2.0N or less 301653 Contact Point
Base Length: 4.0"
Metric
Metric Order No. Description
Dial Spindle 303611 10mm Rod
Order No. Range Resolution Stroke Remarks 303612 20mm Rod
7212 0–200mm 0.01mm 10mm Measuring Force: 1.4N or less 303613 30mm Rod
Base Length: 101.6mm 303614 100mm Rod
with Limit Hands (2 pcs) 303610 Contact Point
No. 2904F Dial Indicator is used for inch models. No. 2902FEB for metric.
Q-3
Q-04 (2003) full size 12/8/03 7:10 PM Page 1
DEPTH GAGES
7238
1.46"
7237
0
5 45
.63"
2.68"
10
7237
40
35
7238
15
.61"
20 30
25
.14"
.71"
2.5"
4.0"
These Dial Depth Gages are designed with the Back Specifications
Plunger Indicators for upward facing readings. With the • Dial Indicator No. 1168
supplied extension rods, depths of up to
8" can be measured. Select either • Dial face: 50–0 (one rev.)
a small or large base to suit your requirements. • Accuracy (forward): less than ±.001"
• Standard Accessories:
Extension rods (4 pcs.): .5, 1, 2, 4"
Exchangeable stylus (1 pc.)
Allen wrench (1 pc.)
Specifications
Back Plunger Dial Depth Gage
Inch
Dial Spindle Base
Order No. Range Resolution Stroke Length Remarks
7237 0–8" .001" .20" 2.5" Measuring Force: 1.4N or less
with Extension Rods (4 pcs)
7238 0–8" .001" .20" 4" Measuring Force: 1.4N or less
with Extension Rods (4 pcs)
Q-4
Q-05 (2003) full size 12/8/03 7:10 PM Page 1
DEPTH GAGES
ø.72"
ø.16"
329-711-30
4"
interchangeable rods (6 or 12psc).
Features Accuracy
• Preset capability. Set any desired measurement on the • Flatness of reference face
display and recall that measurement. (bottom face of base):
• Instant in/mm conversion .00008" for 4" base
• Measurement hold key • Flatness of measuring face of rod: .000012"/0.3µm
• Zero-Set key allows for setting zero measurement at any • Parallelism between reference face and measuring face:
point along spindle. Each unit comes complete with a .00016" + .00004" x ( L*
2"
)/(4 + L/50)µm
battery (offers 6 months of life under normal use), key (*truncated after decimal point.)
spanner, other adjusting wrenches, fitted carrying case, L = maximum measuring length
manual. • Zero point error of rod:
• SPC output provided. ±(.00008" + .00005" x L*3"
)/±(2 + L/75)µm
• Data Send button for transmitting readings to SPC sys- (*truncated after decimal point.)
tems. L = maximum measuring length
• Measuring force: 6–10N • Micrometer Head Accuracy: ±.00012"(±3µm)
• Locking clamp.
• Runs off single SR44 battery.
• Automatic power-off after 20 min. idle time.
Specifications
Digimatic Depth Micrometer (with SPC output)
Inch/Metric
LCD
Order No. Range Resolution Remarks
329-711-30 0–6" .00005" with Interchangeable Rods: 6 pcs
0–152.4mm 0.001mm
329-712-30 0–12" .0001" with Interchangeable Rods: 12 pcs
0–304.8mm 0.001mm
Depth Micrometer (with SPC output)
Metric
Order No. Range Resolution Remarks
329-511-30 0–150mm 0.001mm with Interchangeable Rods: 6 pcs
For SPC output order Connecting Cable 937387 (1m) or 965013 (2m).
Replacement Battery: 541980 (1pc), 541980-10 (10pcs/SET).
Q-5
Q-06 (2003) full size 12/8/03 7:11 PM Page 1
DEPTH GAGES
229-131
.157"
or 4.0")
.71"
(2.5"
.31" .04"
Specifications
Digit Depth Micrometers
Inch
Order No. Range Resolution Remarks
229-127 0–4" .001" with Interchangeable Rods: 4 pcs
Base Length: 2.5", Flatness:.00005"
229-128 0–6" .001" with Interchangeable Rods: 6 pcs
Base Length: 2.5", Flatness:.00005"
229-131 0–4" .001" with Interchangeable Rods: 4 pcs
Base Length: 4.0", Flatness:.00008"
229-132 0–6" .001" with Interchangeable Rods: 6 pcs
Base Length: 4.0", Flatness:.00008"
Q-6
Q-07 (2003) full size 12/8/03 7:11 PM Page 1
DEPTH GAGES
Depth Micrometers
Series 129 – Interchangeable Rod Type
Spindle clamp
located on the
rear side of
the base.
.04"
.157"
(2.5" or 4.0")
129-127
.71"
• Instrument accuracy
Inch ±.00015"
Metric ±0.003mm
Features Accuracy
• Ratchet stop for consistent and repetitive measure- • Flatness of reference face (bottom face of base):
ments. .00005" for 2.5" base/1.3µm for 63.5mm base
• .157" DIA. interchangeable rods, with lapped measuring .00008" for 4.0" base/2µm for 101.6mm base
end, are calibrated and tested at the factory. The rod • Flatness of reference face (bottom face of base):
length can be adjusted, to compensate wear on the .0001"/2.3µm
measuring tip, with two supplied wrenches • Zero point error of rod:
• Satin-chromed finished throughout. L❈
±(.00008"+.00004"x 3 )
• Crisp clear graduations on the thimble L=Maximum measuring length
• Complete with fitted carrying case ❈ Truncated after decimal point.
Specifications
Depth Micrometers
Inch
Order No. Range Resolution Base Length Remarks
129-127 0–4" .001" 2.5" with Interchangeable Rods: 4 pcs.
129-128 0–6" .001" 2.5" with Interchangeable Rods: 6 pcs.
129-149 0–12" .001" 2.5" with Interchangeable Rods: 12 pcs.
129-131 0–4" .001" 4.0" with Interchangeable Rods: 4 pcs.
129-132 0–6" .001" 4.0" with Interchangeable Rods: 6 pcs.
129-150 0–12" .001" 4.0" with Interchangeable Rods: 12 pcs.
Metric
Order No. Range Resolution Base Length Remarks
129-109 0–50mm 0.01mm 63.5mm with Interchangeable Rods: 2 pcs.
129-111 0–100mm 0.01mm 63.5mm with Interchangeable Rods: 4 pcs.
129-112 0–150mm 0.01mm 63.5mm with Interchangeable Rods: 6 pcs.
129-115 0–100mm 0.01mm 101.6mm with Interchangeable Rods: 4 pcs.
129-116 0–150mm 0.01mm 101.6mm with Interchangeable Rods: 6 pcs.
Q-7
Q-08 (2003) full size 12/8/03 7:12 PM Page 1
DEPTH GAGES
Locking clamp on
reverse side holds
measurements.
129-331
.04"
.4"
.71"
.157"
2.4"
2.0"
.315"
.22"
.63" .71" 2.56" .67"
Q-8
Q-09 (2003) full size 12/8/03 7:12 PM Page 1
DEPTH GAGES
AB
Y
OG
EC
H N OL
T
571-211-10
571-213-10
2.756"
.79"
.20"
.345" (diameter)
3.94"
.51"
C D
Dimensions
Range A B C D
0–6"/0–150mm 9.33"
2.88" 1.30"
0–8"/0–200mm 11.30" .63" B
0–12"/0–300mm 15.87" 3.54" 1.65"
0–18"/0–450mm 24.92" 4.45" 2.09" .79" A
Features
• No rack, no pinion, no glass scale. Linear Scale is safe- • LCD unit displays “E-o5” for movement error and “B” for
ly embedded in the hardened stainless steel blade. battery replacement. Note: sliding unit
• Sliding LCD unit offers push button control for in/mm can be moved as fast as 40" per second.
selection, absolute zero setting and turning the display • Power supply: Silver oxide cell (SR-44 1 pc.) 541980
on and off. Battery life is approximately two years with OPTIONAL
normal use. EXTENSION BASES
Order No. Base Sizes
900367 7"
Specifications 900368 10"
Digimatic Depth Gages with Absolute Encoder (with SPC output) 900369 12"
Inch/Metric
LCD
Order No. Range Resolution Accuracy Remarks
0–6" .0005" ±.001" Absolute Function Type
571-211-10
0–150mm 0.01mm
0–8" .0005" ±.001" Absolute Function Type
571-212-10
0–200mm 0.01mm
0–12" .0005" ±.0015" Absolute Function Type
571-213-10
0–300mm 0.01mm
0–18" .0005" ±.002"
571-214-10
0–450mm 0.01mm
0–24" .0005" ±.002"
571-215-10
0–600mm 0.01mm
Metric (Metric only model has metric scale and no inch/mm button) with SPC output
Order No. Range Resolution Accuracy Remarks
571-203-10 0–300mm 0.01mm ±0.03mm Absolute Function Type
SPC output order connecting cable 959149 (1m) or 959150 (2m) for Absolute Function type.
Q-9
Q-10 (2003) full size 12/8/03 7:07 PM Page 1
DEPTH GAGES
700-105
Specifications
Digimatic Depth Gage
Inch/Metric
Order No. Range LCD Resolution Accuracy Remarks
700-105 0-1" .001" ±.008" Plastic body with
0-25mm 0.1mm ±0.2mm metal depth rod
Q-10
Q-11 (2003) full size 12/8/03 7:08 PM Page 1
DEPTH GAGES
527-301-50
527-313-50
3" .433'
.15"
Thickness .157"
.39"
.276"
.197" (diameter)
1.36"
.43"
.63"
RANGE A .16"
3.94"
0–6"/0–150mm 10.24"
0–8"/0–200mm 12.20"
2.76"
0–12"/0–300mm 16.14"
.79"
2.76"
Q-11
Q-12 (2003) full size 12/8/03 7:09 PM Page 1
DEPTH GAGES
527-112
527-113
.39"
.276" .197" (diameter) .98"
1.08"
.51"
.354 (diameter)
.63"
.16"
3.94"
C D
2.56"
900367
2.76"
1.18"
.315"
OPTIONAL .79"
EXTENSION BASES
2.56"
B
Order No. Base Sizes
A
900367 7"
2.56"
900368 10" 6", 8" & 12" Models only
900369 12" Dimensions
Range A B C D
0–6"/0–150mm 10.24"
1.08"
0–8"/0–200mm 12.20" 2.76" 1.36" .43" 24" & 40"
0–12"/0–300mm 16.14" Models only
Features 0–24"/0–600mm 31.50"
4.33" 2.01" .79"
0–40"/0–1000mm 47.24"
• Made of hardened stainless steel.
• Base and measuring faces are
hardened and microlapped.
• Wider extension bases can be
attached.
Specifications
Vernier Depth Gages
Inch
Order No. Range Resolution Remarks
527-111 0–6" .001" with Fine Adjustment Feature
527-112 0–8" .001" with Fine Adjustment Feature
527-113 0–12" .001" with Fine Adjustment Feature
527-114 0–24" .001" with Fine Adjustment Feature
527-115 0–40" .001" with Fine Adjustment Feature
Metric
Order No. Range Resolution Remarks
527-101 0–150mm 0.02mm with Fine Adjustment Feature
527-102 0–200mm 0.02mm with Fine Adjustment Feature
527-103 0–300mm 0.02mm with Fine Adjustment Feature
527-201 0–150mm 0.05mm
527-202 0–200mm 0.05mm
Q-12
R-001 (2003) full size 12/12/03 4:12 PM Page 1
Indicators
Litematic - Series 318 R-2, 3 Dial Indicators/Group O - Inch/Metric R-56
All Models of Linear Gage - Display Units Dial Indicators/Group 1 - Inch/Metric R-57~60
(Counters) R-4 ~ 7 Dial Indicators/Group 2 - Inch/Metric R-61~68
Laser Hologage R-8 Dial Indicators/Group 3 - Inch/Metric R-69~72
LGB/Laser Hologage R-9 Dial Indicators/Group 4 - Inch/Metric R-73~76
LGF Series R-10 One-Revolution Dial Indicators - Group 1&2 R-77
LG/LGM Laser Hologage R-11 One-Revolution Dial Indicators - Group 2 R-78
LGF - Differential Square-wave Output R-12, 13 Back Plunger w/Perpendicular Mounting
LGB - Differential Square-wave Output R-14, 15 Stem - Group 1 R-79
LGE - Differential Square-wave Output R-16, 17 Back Plunger Type Dial Indicators -
LGD, LGD-M - Digimatic Code Output R-18, 19 Group 1 & 2 R-80
LGS - Digimatic Code Output R-20 Hicator - Series 524 R-81, 82
Special Accessories for Gage Head - Hicator II - Series 524 - Dial Comparator R-83
Air Drive Unit R-21 Accessories for Dial Indicators R-84
Mu-Checkers - Series 519 - M400 Series R-22 Backs for Dial & Digimatic Indicators R-85, 86
Special Accessories for Gage Head R-23 Contact Points for Dial & Digimatic Indicators R-87~89
Digital Mini-Checker - Series 519 R-24 Repair Tool Kit, Crystal Setter R-90
Operational Guide and Tech. Data - Dial Gage Stands 7003, Dial Gage Stands with
Installing the Gage R-25, 26 Flat or Grid Anvil R-91
Linear Gage and Counter Connections Comparator Stands - Series 215 R-92~94
& Comparisons of Counter Functions R-27 Precision Granite Stands - Series 517,
EB Counter - Display Unit w/Multiple Limits R-28 Bench Comparators R-95
ES Counter - Assembly Type Display Unit R-29 Mini-Magnetic Stands R-96, 97
EF Counter - Multi-function Type R-30 Mini-Magnetic Stands - Series 984,
EV Counter for Multi-gage System Magnetic Stands R-98
Multi-function Counter R-31 Transfer Stands (Heavy Duty Types) -
Options for ES/EF/EV Counters R-32 Series 519 R-99
IDS Digimatic Indicators w/Absolute Flexi-Stand 7012, Universal Magnetic
Encoder - Series 543 R-33, 34 Stand 7019 R-100
IDC Type Digimatic Indicator w/Absolute Dial Gage Upright Stand, Digimatic
Encoder - Series 543 R-35 Upright Gage R-101
IDC Digimatic Indicators with Absolute Multi-Stand - Multiple Indicator Stands R-102, 103
Encoder - Series 543 R-36, 37 Quick-Set Gaging System R-104
IDC Type Digimatic Indicator w/Abs. Enc. & Dial/Digimatic Indicator and Stand Sets R-105
Peak-Hold - Series 543 R-38
Quick Mini - Series 7 R-106
IDC-CG Digimatic Indicators w/Abs. Enc. for
Bore Gage - Series 543 R-39 Flat Anvil Type R-107, 108
IDU Digimatic Indicator w/Abs Enc. - Series 575 R-40 Dial Thickness Gages R-109, 110
IDF Digimatic Indicator w/Abs Enc. - Digi-Test Digimatic Caliper Gages -
Series 543 R-41, 42 Series 209 R-111, 112
Dial Gage Tester - i-checker - Series 170 R-43, 44 Dial Caliper Gages External Type -
Series 209 R-113, 114
Calibration Testers - Series 521, Dial Gage
Testers - Series 170 R-45 Dial Caliper Gages Internal Type -
Series 209 R-115~117
Dial Indicators - Group 0/1/2/3/4, Dial Indicator
Dial Faces, Order by the Numbers R-46~48 Pocket Thickness Gages - Series 7, Dial Tension
Selection Guide for Dial Indicators - Gage - Series 546 R-118
Inch/Metric Models R-49, 50 Snap Gages - Series 201 R-119, 120
Selection Guide for Dial Indicators - Truetest Test Indicators - Series 513 R-121
Inch/Metric Models R-51, 52 "Quick-Set" Test Indicators - Series 513 R-122
Numerical Index for Dial Indicators R-53~55 "Quick-Set" Indicator Dimensions R-123
R-002 (2003) full size 12/9/03 12:06 PM Page 1
LITEMATIC
Litematic
Series 318
318-213A
(Model VL-50AS*)
318-211A Separate Type
(Model VL-50A*) The measuring unit and the display unit are sepa-
rate on the VL-50AS model. This allows the user to
integrate them into his measurement system. An
optional stand is available.
Features
• Low constant measuring force
• With a measuring force of 1gf(0.01N), the Litematic is ideal for measuring work pieces that can be easily
deformed or that are high-accuracy components
• The Litematic’s motor-driven spindle stops it’s up and down travel when it touches the work piece. Then
it allows measurements of maximums, minimums and deflection volumes.
• Measurement with high-accuracy
• High-resolution with a minimum indicating value of .0000005"/0.01µm, and a wide measuring range of 2"/50mm.
• The measuring table employs ceramics, a material that is rust free, easy to maintain and has a high
wear-resistance.
• A low heat-expansion material is used for the spindle unit, in order to minimize deformation caused by
temperature variations.
R-2
R-003 (2003) full size 12/9/03 1:04 PM Page 1
LITEMATIC
Specifications
Litematic Head
Code No. 318-211A 318-213A
Model No. VL-50A VL-50AS
Measuring Range 0" – 2.0" (0-50.8mm)
Resolution (selectable) .0000005"/.000005"/.00005" (0.01µm/0.1µm/1.0µm)
Display unit Character height .6" (14mm) / 8 digits (excluding "-" sign)
Stroke* 2.06" (51.5mm)
Accuracy at 20°C (0.5+L/100)µm L=Measuring length (mm)
Repreatability* o-=2µinch (0.05µm)
Measuring force* 1gf / 0.01N
Spindle feed speed
Tracing Approx. .03"/s (0.7mm/s
Measuring Approx. .08"/s (2mm/s) or .16"/s (4mm/s)
Quick feed Approx. .3"/s (8mm/s)
Contact point Ø3mm carbide ball (M2.5 x 0.45 thread)
Worktable 100mm Ceramic —
(grooved replaceable)
Data Input Data can be triggered with the foot switch
Output Digimatic and RS-232C
Power Supply 85-264V AC
Power consumption 12W (at max)
Mass 35.2 lbs. (16kg) 11 lbs. (5kg)
Standard accessories AC adapter (357651)
Power cord (930966)
Ground wire
Allen wrench
Optional accessories Foot switch (937179T)
— Dedicated stand (957460)
Output connector (with cover) (02ADB440) (for external control)
RS-LINK/Digimatic connecting cable (1m) (936937)
RS-LINK/Digimatic connecting cable (2m) (965014)
* At normal measurement with the standard contact point.
Dimensions
318-211A 318-213A 957460
R-3
R-004 (2003) full size 12/9/03 12:24 PM Page 1
LINEAR GAGES
Laser Hologage
*: The resolution shown in inches is a calculated value. The actual resolution in inches is determined by the counter setting.
R-4
R-005 (2003) full size 12/15/03 11:33 AM Page 1
LINEAR GAGES
LGM-01100
EV-16P
EB Counter
R-5
R-006 (2003) full size 12/15/03 11:34 AM Page 1
LINEAR GAGES
LGD-M
R-6
R-007 (2003) full size 12/15/03 11:36 AM Page 1
LINEAR GAGES
SD-D2
EV-16D
SD Counter EB Counter
SD-D1
R-7
R-008 (2003) full size 12/9/03 12:28 PM Page 1
LINEAR GAGES
Laser Hologage
0.00001mm (0.01µm) Reading
Dimensions
Unit: inch (mm)
1.79" (45.4)
3.35" (85)
Display unit is
(25)
.98"
resolution of 0.00001mm (0.01µm), which is close to the Ø15h6 -0.011
0
Optional Accessories
Order No. Description Ø
mm
E
ZERO
4.21" (107)
A inch P.SET
R-8
R-009 (2003) full size 12/9/03 12:28 PM Page 1
LINEAR GAGES
LGB/Laser Hologage
0.0001mm (0.1µm) Reading Differential Square-wave Output
Dimensions
Unit: inch (mm) Connecting cable (2m)
Ø.35" (9)
.71" Ø.35" (9)
(18)
3.26" (82.7)
.25"
(6.3) L
542-246
2.95" (75)
Ø.37" 0
542-711 (9.5) -0.009
(15.9)
.63"
Ø.55" (14)
Features
(25)
.98"
0
902432 Extension cable (20m) for LGB Ø15h6 -0.011
Stem dia
238773 Rubber boot for LGB (spare)
971751 Stem fixture for Laser Hologage
0.1µm type with
971752 Stem fixture for Laser Hologage R1.5 carbide point
.71"
.39" (10)
971753 Spindle lifting cable for Laser Hologage (18)
1.57" (40) .79" (20)
971750 Laser Hologage stand
Specifications
Model No. LGB Laser Hologage*1
Order No. 542-246 542-711 542-712
Resolution .000005" (0.0001mm)
Range .20" (5mm) .39" (10mm)
Accuracy (20°C) 0.8µm 0.2µm
Measuring force Upward ( ) Approx. 0.65N or less 0.55N or less 0.1N
Horizontal ( ) Approx. 0.6N or less 0.45N or less —
Downward ( ) Approx. 0.55N or less 0.35N or less —
Dust/Water protection level IP-54 Not Specified
Contact point R1.5mm carbide (mounting threads: M2.5 (P = 0.45) X 5mm)
Stem diameter Ø.37" (9.5mm) Ø.59" (15mm)
Bearing type Linear ball bearing High-precision linear ball bearing
Position-detection sensor Transmission-type photoelectric linear encoder Laser-hologram measurement sensor
Max.Response Speed 14.96" (380mm)/sec 9.84" (250mm)/sec
Output signal 0.4µm pitch, 90° phase difference, 0.25µm pitch, 90° phase difference,
differential square wave differential square wave
(RS-422A equivalent) (RS-422A equivalent)*2
Cable length 2m
Power supply +5V ± 5% (power-supply ripple 200 mV p-p max.)
Power consumption 150mA 300mA
Operating environment 10°C to 30°C (20%RH to 80%RH, without condensation)
Mass 160g 200g (excluding cable)
Compatible counter EF counter with 0.0001mm resolution.
Standard accessories Wrench for contact point (538610) Wrench for contact point (538610)
Wrench for the nut (200168)
Remarks with a clamping nut on the stem Low force type
*1: Only one laser hologage may be connected to the EF counter. *2: The signal output uses a special pitch (intervals) of
To connect two gages, use a 542-062-1 (without AC adapter) 0.25mm. The values are converted to 0.0001mm
and an external power supply (12 to 24 VDC, 1A or greater). resolution on the counter side.
R-9
R-010 (2003) full size 12/9/03 12:29 PM Page 1
LINEAR GAGES
LGF
0.0001mm (0.1µm) Reading Differential Square-wave Output
NEW LGF SERIES with 0.1µm
resolution for high readability
Dimensions Unit: inch (mm)
.14"
(3.5)
0.023" (0.6)
2.26" (57.5) screw top
1.59" (40.5) height) .25" (6.4)
.58" (14.8)
1.44" (36.5)
(17.3)
.44" (11.2) 2.15" (54.6) 0.023" (0.6)
.68"
1.34" .22" (5.6) screw top
1.48" (37.6) height) .79" (20)
(34)+10
1.34" 1.48"
+1
(34) 0 (10.86)
.79" (20)
.90" (23)
.94"
7.96" (202.1)
4.29" (109)
LGF-0125L
(6.7)
0
Ø.31"-0.009
(8)
Optional Accessories
longer stroke
.55"
.42" (10.6) or
(21.5)
0
Ø.59"-0.015
.85"
(14)
M9.5x0.5
(15)
Order No. Description
M14x0.5
(6)
902433 Extension cable (10m) .80" 1.18"
902432 Extension cable (20m) (20.4) (30)
3.26" (82.7)
(13.8) (8.6)
962504 25mm rubber boot (spare)
02ADB680 Thrust stem set (for 10mm LGF model)
02ADB690 Thrust stem set (for 25/50mm LGF model) 2m Cable
Specifications
Order No. 542-144 542-145
Resolution 0.0001mm
Measuring range .39" (10mm) .98" (25mm)
Accuracy (20°C) (0.8 + L150)µm
Measuring force Upward ( ) 1.2N or less 4.6N or less
Horizontal ( ) 1.1N or less 4.3N or less
Downward ( ) 1.0N or less 4.0N or less
Dust/water protection*2 IP-66 equivalent
Contact point Ø.12" (3mm) carbide (mounting threads: M2.5 (P = 0.45) X 5mm) 901312
Stem diameter Ø.31" (8mm) Ø.59" (15mm)
Bearing type Stroke ball bearing
Position-detection method Transmission-type photoelectric linear encoder
Response speed*1 59.06" (1500mm)/sec
Output signal 90° phase difference, differential square wave (RS-422A equivalent);
minimum edge intervals 500 ns for 1 µm model, 250 ns for 0.5 µm model
Signal pitch 2µm
Cable length 2m
Power supply Supply voltage +5V (4.8V to 5.2V), ripple voltage 200mV p-p max.
Power consumption Max. 120mA
Operating environment 0°C to 40°C (20%RH to 80%RH, without condensation)
Mass 250g 290g
Standard accessories Wrench for contact point (538610) Wrench for contact point (210187)
*1: An alarm signal is output when the spindle’s movement speed reaches 1500mm/s. If a Mitutoyo *2: The IP value is a standard indicating the degree
counter is used, an error will be displayed. If the counter is not a Mitutoyo model, contact us regarding of protection against solid foreign matter and
the use of alarm-signal output. When the LGF-150L is used, releasing the contact point after pushing it water. Note that the standard may not apply to
in may cause an overspeed error depending on the extent to which the contact point is pushed inward. certain types of liquids.
R-10
R-011 (2003) full size 12/9/03 12:29 PM Page 1
LINEAR GAGES
RM12BPG-6P
RM12BPG-6P
HR10A-7P-6P
542-313
232
232
LGM-01100
Motor drive type
417.5
417.5
13 34 13 34
Output Cable 2m
Output cable=2m
6
6
36 7 36 7
Drive cable=2m
Motor Drive Unit – use for control of LGM-01100 spindle 50 50
73
73
ø20 0 ø20 -0.013
0
-0.013
Work specification
191.5
Spindle forward speed 1.18" (30mm)/s (low speed)
2.36" (60mm)/s (high speed)
Measuring force Set up with switch
Dimensions (W x D x H) 3.54 x 6.89 x 2.91" (90 x 175 x 74mm) 17
17
External output signal Back for spindle / Forward for spindle
External output signal Stop signal at upper end for spindle LG-01100 LGM-01100
Power supply AC100 to 200V Standard type Motor drive type
Mass 830g
Specifications
Type Standard Type Motor Drive Type
Order No. 542-312 542-313
Resolution 0.1µm
Measuring range 3.94" (100mm)
Accuracy (20°C) 2.5µm
Measuring force Upward ( ) 8N or less Set up with motor drive
Horizontal ( ) 6.5N or less Set up with motor drive
Downward ( ) 5N or less Set up with motor drive
Dust/water protection IP-54 equivalent*
Contact point Ø.12" (3mm) carbide (mounting threads: M2.5 (P = 0.45) X 5mm) 901312
Stem diameter Ø.79" (20mm)
Bearing type Ball bearing
Position-detection method Transmission-type photoelectric linear encoder
Response speed 15.75" (400mm)/sec
Output signal 90° phase difference, differential signal square wave (RS-422A equivalent);
minimum edge intervals 200 ns
Signal pitch 0.4µm
Cable length 2m
Operating environment 0°C to 40°C (20%RH to 80%RH, without condensation)
Mass 640g 780g
* The IP value is a standard indicating the degree of protection against solid foreign matter
and water. Note that the standard may not apply to certain types of liquids.
R-11
R-012 (2003) full size 12/9/03 12:30 PM Page 1
LINEAR GAGES
LGF
0.0005/0.001mm Reading
Differential Square-wave Output
Features
• Excellent structure of protection against dust and water
splash (IP-66) in harsh shop-floor environments.
• Output differential square wave signals for a wide range
of applications.
542-121/131 • Use linear stroke bearings on the spindle movement for
durability.
• Thrust Stem with a clamping nut is optional.
(20)
(50.5)
4.29" (109)
12.22" (310.4)
(6.7)
0
Ø.31"-0.009
(8)
for thrust stem
Ø.59"
Clamping nut
.55"
(21.5)
0
(14) (15) -0.015
M9.5 x 0.5
.85"
Ø.59"
(29.1)
1.15"
0
(15) -0.015
for thrust stem
.48" (12.3)
Clamping nut
(6)
PRCOS-P8M
or longer (stroke)
1.34"
(34)
Connecting .54" .34"
Ø.24" cable 2m Connecting 2.03" (51.5) (13.8) (8.6)
(6.2) LGF with cable 2m or longer (stroke)
reference mark
R-12
R-013 (2003) full size 12/9/03 12:30 PM Page 1
LINEAR GAGES
LGF
0.0005/0.001mm Reading
Differential Square-wave Output
Specifications
542-124* 542-134* 542-125* 542-135* 542-126* 542-136*
Order No. 542-121 542-131 542-122 542-132 542-123 542-133
Resolution 0.001mm 0.0005mm 0.001mm 0.0005mm 0.001mm 0.0005mm
Range .4" (10mm) .98" (25mm) 1.97" (50mm)
Accuracy (20°C) (1.5 + L/50) µm (L=mm)
Measuring force Upward ( ) 1.2N or less 4.6N or less 5.7N or less
Horizontal ( ) 1.1N or less 4.3N or less 5.3N or less
Downward ( ) 1.0N or less 4.0N or less 4.9N or less
Dust/Water protection2 IP-66 equivalent
Contact point Ø3mm carbide (mounting threads: M2.5 (P = 0.45) X 5mm) 901312
Stem diameter Ø.31" (8mm) Ø.59" (15mm)
Bearing type Stroke ball bearing
Position-detection method Transmission-type photoelectric linear encoder
Response speed1 59.06" (1500mm)/s
Output signal 90° phase difference, differential square wave (RS-422A equivalent);
minimum edge intervals 500 ns for 1 µm model, 250 ns for 0.5 µm model
Signal pitch 4µm 2µm 4µm 2µm 4µm 2µm
Cable length 2m
Power supply Supply voltage +5V (4.8V to 5.2V), ripple voltage 200mV p-p max.
Power consumption Max. 120mA
Operating environment 0°C to 40°C (20%RH to 80%RH, without condensation)
Mass 250g 290g 380g
Standard accessories Wrench for contact point (538610) Wrench for contact point (210187)
1: An alarm signal is output when the spindle’s movement speed reaches 1500mm/s. If a Mitutoyo counter is used, an error will be displayed.
If the counter is not a Mitutoyo model, contact us regarding the use of alarm-signal output. When the LGF-150L is used, releasing the contact point after pushing it in
may cause an overspeed error depending on the extent to which the contact point is pushed inward.
2: The IP value is a standard indicating the degree of protection against solid foreign matter and water. Note that the standard may not apply to certain types of liquids.
*with reference mark.
R-13
R-014 (2003) full size 12/9/03 12:31 PM Page 1
LINEAR GAGES
LGB
0.001mm Reading
Differential Square-wave Output
542-223
542-222
542-204 542-222H
542-204H 542-224
542-262 542-270
542-244 542-262H
542-264
.63" (15.9)
fl.35"
4.45" (113)
-0.009
(9) L fl.31"
fl.55" (14) 0
(8)-0.009 fl.37" (9.5) 0
fl.31" L
-0.009
0
(8)-0.009 Clamping nut fl.55" (14)
.99" 1.9" (4.9) No.200365 Clamping nut
.97" .29" (25.1) thread L = .45" (11.5) No.200365
(24.6) (7.3) to .51" (13.0) 1.37"
1.37" .29" 1.9" (4.9)
(34.9) (7.3) (34.9) thread
L = .45" (11.5)
to .51" (13.0)
.19"
(4.9)
3.26" (82.7)
RM12BPG-6P
Knurl
1.18" .80"
1.55" (39.3) 2.37" (60.1)
4.45" (113)
.63" (15.9)
fl.37"
0
(9.5) -0.009 L
fl.31"
0
(8)-0.009
1.15"
Clamping nut (29.3)
.94" (No.200365)
(23.9) Stroke
542-230
.41" (10.5mm)
Stroke
.41" (10.5mm) L = .45" (11.5) or longer
or longer to .51" (13.0)
R-14
R-015 (2003) full size 12/9/03 12:32 PM Page 1
LINEAR GAGES
LGB
0.001mm Reading
Differential Square-wave Output
Features
• Extremely compact design. Available with an outside diame- • The ball bearings used in the spindle unit ensure superb
ter as small as 8mm. durability.
• The small photoelectric linear encoder assures high preci-
sion over the entire stroke range.
Individual specifications
Order No. 542-204 542-204H 542-222 542-222H 542-224 542-230 542-223
Stem 8mm diameter, straight stem
Order No. 542-244 542-262 542-262H 542-264 542-270
Stem 9.5mm diameter, straight stem with nut
Measuring range .2” (5mm) .4” (10mm)
Accuracy (20°C) 2 µm 1 µm 2 µm 1 µm 2 µm
Measuring Upward ( ) 0.65N or less 0.8N or less 0.6N or less 0.8N or less
force Horizontal ( ) 0.6N or less 0.75N or less 0.55N or less 0.75N or less
Approx. Downward ( ) 0.55N or less 0.7N or less 0.5N or less 0.7N or less
Mass 145g 145g 150g 150g 150g 165g 165g
(542-204) (542-222) (542-222H) (542-224) (542-230)
160g 170g 170g 170g 170g
(542-244) (542-262) (542-262H) (542-264) (542-270)
Spindle becomes Spindle retreats
Air-lifter mechanism None free when air when air
is supplied is supplied
Common specifications
Resolution 0.001mm
Dust/water protection IP-54
Contact point Ø3mm in carbide (mounting threads: M2.5 (P = 0.45) X 5mm), 901312
Bearing type Stroke ball bearing
Position-detection method Transmission-type photoelectric linear encoder
Response speed 900mm/sec
Output signal/signal pitch 4µm pitch, 90° phase difference, differential square wave (RS-422A equivalent)
Cable length 2m
Power supply Supply voltage: 4.8 to 5.3V, ripple voltage 200mV p-p max.
Power consumption 80mA
Operating environment 0°C to 40°C (20%RH to 80%RH, without condensation)
Required air-pressure range 0.3 to 0.4 MPa (3 to 4kg/cm2) (Required only for models equipped with air lifters)
R-15
R-016 (2003) full size 12/9/03 12:32 PM Page 1
LINEAR GAGES
LGE
0.005mm Reading
Differential Square-wave Output
Features
542-601 542-602
• With a rubber boot for use in harsh environments.
• Optional thrust stem and tightening nut facilitate setup of
the LGE linear gage in holes of a plate or fixture.
Optional Accessories
Order No. Description
238772 10mm rubber boot (spare)
962504 25mm rubber boot (spare)
962505 50mm rubber boot (spare)
02ADC730 Ø9.5mm Thrust stem set
(for 10mm LGE model)
542-604 542-603 02ADC740 Ø18mm Thrust stem set
(for 25mm/50mm LGE model)
Dimensions
R-16
R-017 (2003) full size 12/9/03 12:33 PM Page 1
LINEAR GAGES
LGE
0.005mm Reading
Differential Square-wave Output
Specifications
Order No. 542-601 542-604 542-602 542-603
Resolution 0.005mm (5µm)
Measuring range .4” (10mm) 1” (25mm) 2” (50mm)
Accuracy (20°C) 20µm 30µm
Measuring Upward ( ) 1.2N or less 4.6N or less 5.7N or less
force Approx. Horizontal ( ) 1.1N or less 4.3N or less 5.3N or less
Downward ( ) 1.0N or less 4.0N or less 4.9N or less
Dust/water protection1 IP-66 equivalent IP-54 equivalent IP-66 equivalent
Contact point Ø3mm carbide (mounting threads: M2.5 (P = 0.45) X 5mm), 901312
Stem diameter Ø8mm Ø15mm
Bearing type Stroke ball bearing
Position-detection method Capacitance-type incremental linear encoder
Response speed2 Static: 1400mm/s Dynamic: 17.5mm/s
Output signal/signal pitch 20µm pitch, 90° phase difference, differential square wave (RS-422A equivalent)
Output cable length 2m
Power supply Supply voltage 5V (4.8V to 5.2V), ripple voltage 200mV p-p max.
Power consumption 100mA
Operating environment 0°C to 40°C (20%RH to 80%RH, without condensation)
Lifter mechanism None Built-in air lifter3 None
Mass 200g 220g 250g 300g
Accessories Wrench for contact point (538610) Wrench for contact point (210187)
1: The IP value given is for water. Note that the unit may not be able to maintain resistance to certain types of liquids.
2: Static - The maximum movement speed at which no overspeed error occurs.
Dynamic - The maximum movement speed at which measurement by scanning is possible.
3: The air-supply pressure for 524-604 is 0.3 to 0.4 MPa. The spindle moves forward (becomes free) when air is supplied.
Use an air hose with an inside diameter of 2.5mm.
R-17
R-018 (2003) full size 12/15/03 11:37 AM Page 1
LINEAR GAGES
LGD
.0005"/0.01mm Reading
Digimatic Code (SPC) Output 575-321/331
Features
• The use of an absolute scale in the sensor
575-322/332
makes it possible to maintain the origin
setting even when the power is switched off.
• Special linear ball bearings are used for the
spindle guide to ensure a long service life.
• Optional thrust stem and tightening nut
facilitate setup of the LGD linear gage in
holes of a plate or fixture. 575-323/333
Dimensions 575-324/334
The dimensions of the LGD is Unit: inch (mm) Optional Accessories
the same as that of the LGE,
Order No. Description
as indicated on the page at left. .79" (20) .34" (8.6)
The only differences are the 238772 Spare rubber boot (for 10mm LGD model)
shape and size of the connector 962504 Spare rubber boot (for 25mm LGD model)
1.46" (37)
at the end of the cable. 962505 Spare rubber boot (for 50mm LGD model)
575-321/331: Refer to 542-601 02ADC730 Ø9.5mm Thrust stem set
(for 10mm LGD model)
575-322/332: Refer to 542-602 02ADC740 Ø18mm Thrust stem set
575-323/333: Refer to 542-603 (for 25mm/50mm LGD model)
575-324/334: Refer to 542-604 ■*
965275■ Digimatic Power Supply Unit
*: ■ is left blank or an appropriate suffix (A or E) is inserted, depending on
the AC supply voltage (blank - 100V; A - 120V; E - 240V).
Specifications
Order No. 575-321 575-331 575-324 575-334 575-322 575-332 575-323 575-333
Resolution 0.01mm .0005" 0.01mm .0005" 0.01mm .0005" 0.01mm .0005"
Measuring range 10mm 0.4" 10mm 0.4" 25mm 1.0" 50mm 2.0"
Accuracy (20°C) 20µm .001" 20µm .001" 20µm .001" 30µm .0012"
Measuring Upward ( ) 1.2N or less 4.6N or less 5.7N or less
force Approx. Horizontal ( ) 1.1N or less 4.3N or less 5.3N or less
Downward ( ) 1.0N or less 4.0N or less 4.9N or less
Dust/water protection1 IP-66 equivalent IP-54 equivalent IP-66 equivalent
Contact point Ø3mm carbide (mounting threads: M2.5 (P = 0.45) X 5mm), 901312
Stem diameter Ø8mm Ø15mm
Bearing type Stroke ball bearing
Position-detection method Capacitance-type absolute linear encoder
Response speed Unlimited; measurement by scanning cannot be performed
Output signal Digimatic output
External input Origin-setting signal (absolute positional origin can be changed externally)
Output cable length 2m
Power supply Supply voltage 5V (4.5V to 5.5V), ripple voltage 200mV p-p max.
Power consumption 20mA
Operating environment 0°C to 40°C (20%RH to 80%RH, without condensation)
Lifter mechanism None Built-in air lifter2 None
Mass 200g 220g 250g 300g
Standard accessories Wrench for contact point (538610) Wrench for contact point (210187)
1: The IP value given is for water. Note: that the unit may not be able to maintain 2: The air-supply pressure for 575-324 and 575-334 is 0.3 to 0.4 MPa.
resistance to certain types of liquids. The spindle moves forward (becomes free) when air is
supplied. Use an air hose with an inside diameter of 2.5mm.
R-18
R-019 (2003) full size 12/9/03 12:34 PM Page 1
LINEAR GAGES
LGD-M
.0005"/0.01mm Reading
Digimatic Code (SPC) Output
Dimensions
575-325
Features
• The use of an absolute scale in the sensor makes it
possible to maintain the origin setting even when the
power is cut off.
• The spindle is supported at both ends, improving the
accuracy to 15mm.
Optional Accessories
Order No. Description
02ACA376 Spare rubber boot
■*
965275■ Digimatic Power Supply Unit
*: ■ is left blank or an appropriate suffix (A or E) is inserted, depending on
the AC supply voltage (blank - 100V; A - 120V; E - 240V).
Specifications
Order No. 575-325 575-335
Resolution 0.01mm .0005”
Measuring range 10mm .4”
Accuracy (20°C) 15µm .0006”
Measuring force Upward ( ) 2.0N or less
Horizontal ( ) 1.8N or less
Downward ( ) 1.6N or less
Dust/water protection* IP-66 equivalent
Contact point Ø3mm carbide (mounting threads: M2.5 (P = 0.45) X 5mm), 901312
Stem diameter Ø8mm
Bearing type Slide-bearing type
Position-detection method Capacitance-type absolute linear encoder
Response speed Unlimited; measurement by scanning cannot be performed
Output signal Digimatic output
External input Origin-setting signal (absolute positional origin can be changed externally)
Output cable length 2m
Power supply Supply voltage: 5V (4.5V to 5.5V), Ripple voltage: 200mV p-p max.
Power consumption 20mA
Operating environment 0°C to 40°C (20%RH to 80%RH, without condensation)
Mass 182g
Standard accessories Wrench for contact point (538610)
*: The IP value given is for water. Note that the unit may not be able to maintain resistance to certain types of liquids.
R-19
R-020 (2003) full size 12/9/03 12:36 PM Page 1
LINEAR GAGES
LGS
.0005"/0.01mm Reading
Digimatic Code (SPC) Output
Dimensions
Optional Accessories
Order No. Description
238774 Spare rubber boot
903594 Air drive unit (for 575-301 and 575-302)
903598 Air drive unit (for 575-311 and 575-312)
Specifications
Order No. 575-301 575-302 575-311 575-312
Resolution 0.01mm .0005”
Measuring range 12mm .5”
Direction (UP) plus minus plus minus
Accuracy (20°C) 0.02mm .001”
Measuring force Upward ( ) Approx. 1.96N or less
Horizontal ( ) Approx. 1.67N or less
Downward ( ) Approx. 1.47N or less
Dust/water protection1 IP-66
Contact point Ø3mm carbide (mounting Ø5/32” (DIA) steel (4-48UNF)
threads: M2.5 (P = 0.45) X 5mm)
Maximum response speed 1600mm/s; measurement by scanning cannot be performed
Stem diameter Ø8mm Ø9.52mm (.375”)
Bearing type Slide-bearing type
Position-detection method Capacitance-type incremental linear encoder
Output signal Digimatic output
Power supply DC5 to 10V (5mA max.)
Cable length 2m
Operating environment 0°C to 40°C (20%RH to 80%RH, without condensation)
Mass 170g (including cable)
1: The IP value given is for water. Note that the unit may not be able to maintain resistance to certain types of liquids.
R-20
R-021 (2003) full size 12/9/03 12:36 PM Page 1
LINEAR GAGES
Dimensions
903594 02ADE230
A B C D E 02ADE250/
02ADE250 1.0" 1.18" 3.06" 1.63" 4.35" 02ADE270
(25.5) (30) (77.6) (41.5) (110.5)
02ADE270 2.0" 1.97" 3.78" 2.62" 6.28"
(51) (50) (95.9) (66.5) (159.5)
Specifications
Order No. 903594 903598 02ADE230 02ADE250 02ADE270
Stroke 10mm .4” 10mm 25mm 50mm
Applicable gage model LGS LGF, LGE, LGD
Air supply 0.49MPa 0.2 to 0.4MPa
Air hose to be used Inner diameter : Ø2.5mm
Mass 60g 150g 250g 300g
R-21
R-022 (2003) full size 12/9/03 12:37 PM Page 1
MU-CHECKERS
Mu-Checkers
Series 519 – M400 Series for High Accuracy Millionths/Microns
Mitutoyo M400 Analog Mu-Checkers
Features
• Available in STANDARD and DIFFERENTIAL models.
• The operator can select either the INCH or METRIC
mode.
• “ZEROSET” features allows the operator to quickly
and accurately reset the indicator for the next applica-
tion in either measuring/inspecting modes. 519-402A 519-404A
• All controls are easy to reach including the range
selector.
• All analog units can output digital data via an optional
RS-232C interface.
• Uses Mitutoyo cartridge and lever-type indicators.
Gage Head B
Gage Head A
A+B A-B A-B
Application
• All controls, including “ZEROSET” are easy to reach. Examples
Gage Head A
• Probe linearity is set using master or optional gage Differential Gage Head A Gage Head B
Gage Head B
block. Measurements
Analog Mu-Checkers
Inch/Metric
Order No. Style Range Resolution Remarks
Standard type ±.05"/±1500µm .001"/50µm •Accuracy: ±1% Full Scale
519-402A
(One Probe type) ±.015"/±500µm .0005"/10µm • Analog output Voltage: ±1VDC/Fullscale
Differential type ±.005"/±150µm .0001"/5µm (Accuracy: ±0.1% to ±0.3% depending on the probe.)
519-404A
(Two Probe type) ±.0015"/±50µm .00005"/1µm • Power: AC Adapter (Part No. 965565A)
±.0005"/±15µm .00001"/0.5µm • Optional Accessory
±.00015"/±5µm .000005"/0.1µm • Digimatic code Output Interface: No. 965691
• RS-232C Interface: No. 965690A
• Dimensions: 5.3"W x 7.2D x 8.3H
• Weight 4 lb.
Digital Mu-Checkers
Inch/Metric
Order No. Style Range Resolution Remarks
Differential type •Accuracy: ±3 digit ±1
519-412A ±.08"/±2mm .00005"/0.001mm
(Two Probe type) • Analog output Voltage: ±1 VDC/Full Scale
Limit type (Accuracy: ±0.1% to ±0.3%—depending on the probe.‚
519-414A ±.008"/±0.2mm .000005"/0.0001mm
(Two Probe type) • Data output: Digimatic Codeout Interface.
• Measuring Mode: ABS/CMP (switchable)
• Power: AC Adapter (Part No. 965565A)
• Optional Accessory
RS-232C Interface: No. 965838B
• BCD Interface No. 965839A
*Dimensions: 5.3"W x 7.2"D x 8.3"H
*Weight: 3.74 lb.
R-22
R-023 (2003) full size 12/9/03 12:38 PM Page 1
LINEAR GAGES
■*
Digimatic external power unit: 965275■
*: ■ is left blank or an appropriate suffix (A or E) is inserted, depending on
the AC supply voltage (blank - 100V; A - 120V; E - 240V).
Sample application 1: Use it as an external power supply when Sample application 2: Use it for setting the absolute origin when
connecting to other equipment (such as MUX-10 or DP-1HS) connecting an absolute-type LGD or LGD-M to a display unit other
instead of the display unit. than the ES and EV counters.
R-23
R-024 (2003) full size 12/9/03 12:39 PM Page 1
MU-CHECKERS
Digital Mini-Checker
Series 519
519-621A
R-24
R-025 (2003) full size 12/9/03 12:39 PM Page 1
LINEAR GAGES
R-25
R-026 (2003) full size 12/9/03 12:40 PM Page 1
LINEAR GAGES
R-26
R-027 (2003) full size 12/9/03 12:40 PM Page 1
LINEAR GAGES
R-27
R-028 (2003) full size 12/9/03 12:41 PM Page 1
LINEAR GAGES
EB Counter
Display Unit with Multiple Limits
Setting Functions for Linear Gage System
Features Dimensions
• 3-/5-step x 7-bank tolerance
judgement or 7-channel x 2-bank
limit setting.
• Standard serial BCD signal
output for simple wiring with a
PC, programmable controller, etc..
• Simple analog signal output for
a dynamic measurement.
• DIN compatible 3.86" x 1.89" (96 x 48mm)
and Panel-mounting compact body design.
• Choice of three models for various gage inputs.
Optional Accessories
Order No. Description
02ADB440 Output connector plug (with cover)
02ADD930 Terminal block connection cable
■ ■ ■*
527428■ AC Adapter
02ADF180 10-Key Unit
*: ■ ■ ■ is determined by the power-supply voltage specified.
Used in combination with 02ADD930.
Specifications
Order No. 542-092 542-094 542-093
Model EB-11P EB-11Z EB-11D
Applicable input Differential square-wave Differential square-wave Digimatic code (SPC)
Applicable gage LGB, LGE, LGF*, 100mm LG LGF with scale reference point LGD, LGS
Number of gage input 1 1 1
Resolution (count display range) .0005" (±99.9995") 0.01mm (±999.99mm)
.00005" (±99.99995") 0.005mm (±999.995mm) —
.00005" (±9.99995") 0.001mm (±999.999mm)
.000005" (±.999995") 0.0005mm (±99.9995mm) —
Selection with the parameter Auto-selection with gage connected
Display 6-digit and a negative (-) sign LED (green), Tolerance judgment indication LED (orange, green, red)
Function Presetting, 3-/5-step x 7-bank or 7-channel x 2-bank limit setting, GO/±NG judgement,
GO/±NG signal output, MAX/MIN/TIR (runout) measurement, Counting direction switching,
Scale reference point, mm/inch switching, Count standby display, Key protect
Output Tolerance judgment, Serial BCD output, Simplified analog output, Digimatic output
External control Preset, Data hold, Bank switching, Peak mode switching, Analog range selection
Error display/output Power-supply voltage error, overspeed error, overflow error, gage error,
communication error, tolerance setting error
Max. input frequency/count speed** 1.25MHz (2-phase square waveform)/5MHz —
Power supply/Power consumption Via AC adapter (12V to 24V DC, 500mA (max.))/6VA
Operating environment 0°C to 40°C (20%RH to 80%RH, without condensation)
Mass .88 lbs. (400g)
Standard accessory Six washers for adjusting the mounting plate thickness
* For LGF w/ scale reference point use 542-094
** Depending on the gage connected. The input frequency of the scale reference point signal (EB-11Z) is also restricted by the gage connected
R-28
R-029 (2003) full size 12/9/03 12:41 PM Page 1
LINEAR GAGES
ES Counter
Assembly Type Display Unit
Features
• DIN compatible compact panel-mounting 3.78" x 1.89"
(96 x 48mm). It can be easily incorporated into each
system instrument.
• Two choices of data output: the BCD data output type
(542-053) and the tolerance judgment output type Dimensions -V +V OUTPUT
Serial 000001
Model ES-11 DL
Code No. ***-***
Approx. INPUT
.39" (10)
1.75" (44.4) 3.60" (91.4)
-24V
12
DC0mA
20 -V
0
AD
D40 +V
02 I
o. EV- 01
e N 0000
Cod el No.
Modial T
N
PA
OU
Ser
JA
DE
IN
K
MA LIN
RS
IN
Optional Accessories
Order No. Description
02ADB440 Output connector plug (with cover) .26" (6.6) GO/±NG judgment indicator (542-051 only)
■ ■ ■*
527428■ AC Adapter Dimensions of opening 1.77"+0.8 1.89"
(panel mounting) (45) 0 Fn P.SET
(48)
*: ■ ■ ■ is determined by the power-supply voltage specified.
Used in combination with 02ADD930.
3.78" (96)
3.62" (92) +0.8
0
Specifications
Order No. 542-051 542-053 542-055 542-057
Applicable input Differential square-wave Digimatic code (SPC)
Applicable gage LGB (excluding 0.0001mm resolution), LGD, LGD-M, LGS
LGF(0.001mm reading only), LGE, 100mm LG
No. of gage input 1
Resolution .00005”, .0005”, 0.001mm, 0.005mm, 0.01mm .0005”, .00005”*, 0.01mm, 0.001mm*
(Automatically set depending on the gage.)
Display 6-digit and a negative [-] sign LED (red)
Function • Preset • Limit setting • Preset • BCD data output • Preset • Limit setting • Preset • BCD data output
• GO/±NG judgment • inch/mm switch • GO/±NG judgment • inch/mm switch
• inch/mm switch • +/- direction switch • inch/mm switch • +/- direction switch
• +/- direction switch • +/- direction switch
Output • Limit signal (3 or 5-step) • Measurement data • Limit signal (3 or 5-step) • Measurement data
(open-collector) • Normal signal • Normal signal • Normal signal • Normal signal
External control • Preset • Preset • Preset • Preset
signal input • Data hold • Data hold • Data hold • Data hold
• Data output prohibit • Data output prohibit
Error display/output Power-supply voltage error, overflow error, gage error, system error,
overspeed error (542-051 and 542-055 only), tolerance setting error (542-051 and 542-055 only).
Maximum input frequency 750kHz (two-phase square wave) —
Power supply Terminal block (M3 screws); 12 to 24V DC, 500mA (max.) (Through an external power supply)
Operating environment 0°C to 40°C (20%RH to 80%RH, without condensation)
Mass 400g
Standard accessories Six washers for adjusting the mounting plate thickness
*: Will not be indicated when combined with an LG gage.
R-29
R-030 (2003) full size 12/9/03 12:42 PM Page 1
LINEAR GAGES
EF Counter
Multi-function Type
Features
• DIN compatible Panel-mounting type and DIN size
(144 x 72mm). It can be easily incorporated into each
system instrument.
• This counter can be used on a desktop by mounting it
on the supplied stand leg.
• The standard RS-232C interface allows easy
Dimensions communication with an external PC.
Unit: inch (mm)
6.17" (156.7)
• The RS Link function permits multiple EF counters
5.67" (144) 5.83" (148.2) (6 units maximum) to be connected with daisy chain
Showing the
5.39" (137)
AC adapter and data to be input/output from one channel of the
connection
terminal RS-232C interface.
2.83"
(72) • The maximum value, minimum value, and TIR (runout)
.20" (5.1) measurements are possible.
• The 2-gage input type can perform 2-axis display and make
10¡
.12"
Rubber foot (provided) .44" 1.06" (27) addition or subtraction calculations between 2 gages.
(3.1)
Stand (provided) (11.2) 5.39" (137)
Optional Accessories
5.43" (138) 5.43" (138) +1
+0.5
Order No. Description
Dimensions of opening 02ADB440 Output connector plug (with cover)
2.68" (panel mounting) 2.68"
(68) Panel thickness: (68) +0.7
+0.3 02ADD950 SPC data output/RS link cable (0.5m)
.04 to .13" (1 to 3.2mm)
936937 SPC data output/RS link cable (1m)
965014 SPC data output/RS link cable (2m)
Specifications
Order No. (Order number suffix denotes the AC adapter type equipped.)
120V 542-065A 542-066A 542-060A 542-062A
Applicable input Differential square-wave
Applicable gage LGF with reference mark LGB (including 0.0001mm resolution),LGF, LGE,
100mm LG, LGH with 0.0001mm resolution1
Number of gage input 1 2 1 2
(Single-display) (Double-display) (Single-display) (Double-display)
Resolution (Depending on the linear .000005”, .00005”, .0005”, .000005”, .00005”, .0005”,
gage type connected) 0.0005mm, 0.001mm, 0.005mm, 0.01mm 0.0001mm, 0.0005mm, 0.001mm, 0.005mm,0.01mm
Display 8-digit and a negative [-] sign LED (green)
Function Zeroset, preset, limit setting (3 or 5-step), GO/±NG judgment, GO/±NG signal output,
MAX/MIN/TIR (runout) measurement, counting direction switching, double reading, inch/mm
switching, sum/difference calculation of 2 gages (542-061, 542-062 only), output mode selection
Output I/O: Tolerance judgment output (3/5 stages), normal operation output
RS-232C or Digimatic code (selectable): Various measurement data
External Control I/O: Preset, Data hold and Error clear
RS-232C: Displayed value output,MAX/MIN/TIR switching,Zero set,peak value clear,
preset value input, tolerance value input and error clear
RS Link Up to six EF counters may be connected via one RS-232C port.(daisy chain)
Error display/output Power-supply voltage error, overspeed error, overflow error, gage error,
communication error, and tolerance setting error
Maximum input frequency 1.25MHz (differential square-wave): Max counting Speed : 5MHz
Power supply Via AC adapter (12 - 24V DC, 700mA (max))
Operating environment 0°C to 40°C (20%RH to 80%RH, without condensation)
Mass (main unit only) 800g 840g 760g 800g
Standard accessories Stand leg (one piece), rubber feet (four pieces), washer for adjusting the mounting plate thickness
when securing the plate (six pieces), DC plug (one piece), AC adapter (excluding model 542-06X-1)
1: Only one LGH may be connected to one AC adapter
(provided as a standard accessory). To connect two gages,
use a 542-062-1 and a separate power supply
(12 to 24V DC, 1A or greater).
R-30
R-031 (2003) full size 12/9/03 12:42 PM Page 1
LINEAR GAGES
EV Counter
for Multi-gage System Multi-function Counter
Features
• Up to six gages can be connected to one unit.
• Able to connect up to 10 EV counters to one personal
computer using the RS link function to facilitate the
configuration of a multi-point measurement system
comprising a maximum of 60 gages.
• A range of output modes to choose from; I/O output
for tolerance judgment and segment output, BCD data For the gage with For the gage with
output and RS-232 output are available. differential-square-wave output Digimatic Code output
• Peak-hold measurements are possible for maximum
value, minimum value, runout (TIR), etc. Dimensions
• Able to calculate a sum, average, maximum, minimum, Unit: inch (mm)
maximum difference, etc., between gages connected
to the same unit. .16" (4)
Optional Accessories
RS LINK
IN OUT Err. 5 4
LOAD 8 7 MODE 6 3 SEL. 2 1 DATA
2.52" (64)
2.83" (72)
INPUT
F E D C B A
.24"
(6) .20" .20"
02ADD950 SPC data output/RS link cable (0.5m) .16"
5.35" (136)
.16"
(5) 6.34" (161)
(5)
936937 SPC data output/RS link cable (1m) (4) 5.67" (144) (4)
.63" 5.47" (139)
.63"
965014 SPC data output/RS link cable (2m) (16) (16)
.26"
02ADD930 Terminal block connection cable (6.5)
■ ■ ■*
527428■ AC Adapter
.18" (4.5)
*: ■ ■ ■ is determined according to the specified power-supply voltage.
Used in combination with 02ADD930. Interconnecting Affixing an
EV counters EV counter
Specifications
Order No. 542-063 542-064 542-067
Applicable input Differential square-wave Digimatic Code (SPC) Differential square-wave
Applicable gage LGB (excluding 0.0001mm resolution), LGD, LGS LGF with reference mark
LGF, LGE, 100mm LG
Number of gage input 6
Resolution (internal) .000005”, .00005”, .0005”, .00005”*, .0005”, .000005”, .00005”, .0005”,
no display capability 0.0005mm, 0.001mm, 0.001mm*, 0.01mm 0.0005mm, 0.001mm,
0.005mm, 0.01mm 0.005mm, 0.01mm
Function GO/±NG judgment, GO/±NG signal output, MAX/MIN/TIR (runout) measurement, counting direction switching,
inch/mm switching, calculation of sum, average, maximum, minimum and maximum difference
between specified axes, and output-mode selection
Output I/O: Normal operation output and GO/±NG signal (three steps), measurement data (BCD code),
or 21-stage segment output (selectable) RS-232C: Various measurement data
External Control I/O: Axis designation, preset, data hold, and error clear RS-232: Displayed value output command,
MAX/MIN/TIR switching and peak value clear, zero set, preset value input,
tolerance value input, error clear, and command to output calculated value between specified axes
RS Link Up to 10 EV counters may be connected via a single RS-232 port. (daisy chain)
EV and EF counters can be mixed (in which case a total of six counters can be connected).
Error display/output Power-supply voltage error, overspeed error, overflow error, gage error, communication error, and tolerance setting error
Maximum input frequency 1.25MHz (differential square-wave): — 1.25MHz (differential square-wave):
Max counting Speed : 5 MHz Max counting Speed : 5 MHz
Power supply Terminal block (M3 screws), DC +12 to +24V, 700mA (max.)
Operating temperature 0°C to 40°C (20%RH to 80%RH, without condensation)
Mass (main unit only) 910g 830g 910g
Standard accessories Mounting feet (four pieces), brackets (four pieces), and mounting screws M4 x 8 (eight pieces)
R-31
R-032 (2003) full size 12/9/03 12:43 PM Page 1
LINEAR GAGES
GAGE
MAX
TIR
MIN
EV-1 Features
1.75" (44.4)
1.89" (48)
UNIT +NG
GO
• Display unit for the EV counter.
-NG
• Using this display allows various settings for the EV
DISP Fn MODE P.SET
counter without a personal computer or other equipment.
• Able to display each axis measurement value and,
3.78" (96) .26" 2.64" (67) .43" GO/NG judgment result, total GO/NG judgment result
(6.6) (11)
for all axes, setting details, and errors
• DIN compatible compact panel-mounting - cutout
Code No. 02ADD400
Model EV-1
Serial No. 000001
dimensions 1.77" + 00.31" x 3.62" + 0.31"
0 (45 + 00.8 x 92mm + 0.8
0 )
DC12-24V
200mA
MADE IN JAPAN
Specifications
Number of connectable units One display unit allows external display and setting for one EV counter.
Displayed digits It uses a single sign plus six digits (EV counter operates on eight-digit data internally
but displays only the last six digits).
Channel display (also for display of judgment result): 3 (three-color LED)
LED display Measurement mode display (current, maximum, minimum, runout):
2 Status display: 1 (two-color)
Operating switches 4
Switches and their functions Channel switching, measurement mode switching (current value, maximum value,
minimum value and runout), parameter setting, preset, and tolerance setting
Input/output RS Link connectors: 1 in and 1 out.
Error display Overspeed, gage error and others.
Power supply Terminal block (M3 screws), DC +12 to +24V, 200mA
Operating temperature (humidity) range 0°C to 40°C (20%RH to 80%RH, without condensation)
R-32
R-033 (2003) full size 12/9/03 12:43 PM Page 1
DIGIMATIC INDICATORS
Optional Accessories
540774 Release cable 02ACB630 Adjustable back for ISO/JIS type
903424 Lifting lever assy for ISO/JIS type 02ACB620 Adjustable back for AGD type
903425 Lifting lever assy for AGD type 02ACB640 Back with offset lug
02ACB420 Lug-on-center back for ISO/JIS type 02ACB650 Magnetic back
02ACB430 Lug-on-center back for AGD type 02ACB670 Back with screw mount for ISO/JIS type
02ACB440 Flat back 02ACB660 Back with screw mount for AGD type
02ACB610 Back with post 02ACB680 Back with adjustable bracket
Optional
Gage Stand
7004
R-33
R-034 (2003) full size 12/9/03 12:44 PM Page 1
DIGIMATIC INDICATORS
ISO/JIS Type (8mm Diameter Stem and M2.5 X 0.45 Contact Point)
Order No. w/lug back 543-682 543-681 543-691 543-695 543-690 543-694
Model No. ID-S1012M ID-S1012 ID-S112M ID-S112PM ID-S112 ID-S112P
Order No. w/flat back 543-682B 543-681B 543-691B 543-695B 543-690B 543-694B
Model No. ID-S1012MB ID-S1012B ID-S112MB ID-S112PMB ID-S112B ID-S112PB
Measuring Range 0–.5"/0–12.7mm 0–12.7mm 0.5"/0–12.7mm 0–12.7mm
LCD Resolution .0005"/0.01mm 0.01mm .00005"/0.001mm 0.001mm
Accuracy (20°C) .0008" 0.02mm .00012" 0.003mm
Measuring force 0.9N or less 0.9N or less 2.0N or less 2.0N or less 2.0N or less 2.0N or less
Dust-resist* Dust-resist*
* Dust-resistant models conform to IP-53 Protection Level (All others equivalent to IP-42)
Optional Connecting cables: 905338 (1m), 905409 (2m) with data send button: 959149 (1m), 959150 (2m)
R-34
R-035 (2003) full size 12/9/03 12:45 PM Page 1
DIGIMATIC INDICATORS
543-463B
R-35
R-036 (2003) full size 12/9/03 12:45 PM Page 1
DIGIMATIC INDICATORS
Specifications
.0005"/0.01mm Resolution
Order No. w/lug back 543-272 543-279 543-276
Model No. ID-C1012E ID-C1012PE ID-C1012CE
Order No. w/flat back 543-272B 543-279B 543-276B 543-456B 543-466B
Model No. ID-C1012EB ID-C1012PEB ID-C1012CEB ID-C1025EB ID-C1050EB
Measuring Range 0–.5"/0–12.7mm 0–1"/0–25mm 0–2"/0–50mm
LCD Resolution .0005"/0.01mm
Accuracy (20°C) .0008" .0012" .0016"
Measuring force 0.9N or less 2.0N or less .2, .3, .4, .5** 1.8N or less 2.3N or less
Dust-resist* Low F type**
* Dust-resistant models conform to IP-53 Protection Level (All others equivalent to IP-42)
** Selectable through a combination of included spring and weight
.00005"/0.001mm Resolution
Order No. w/lug back 543-252 543-259 543-256
Model No. ID-C112E ID-C112PE ID-C112CE
Order No. w/flat back 543-252B 543-259B 543-256B 543-452B 543-462B
Model No. ID-C112EB ID-C112PEB ID-C112CEB ID-C125EB ID-C150EB
Measuring Range 0–.5"/0–12.7mm 0–1"/0–25mm 0–2"/0–50mm
LCD Resolution .00005"/0.001mm
Accuracy (20°C) .00012" .00016"
Measuring force 1.5N or less 2.0N or less .4, .6, .7N** 1.8N or less 2.3N or less
Dust-resist* Low F type**
* Dust-resistant models conform to IP-53 Protection Level (All others equivalent to IP-42)
** Selectable through a combination of included spring and weight
.0001"/0.001mm Resolution
Order No. 543-253
Model No. ID-C112T
543-253B 543-453B 543-463B
ID-C112TB ID-C125TB ID-C150TB
Measuring Range 0–.5"/0–12.7mm 0–1"/0–25mm 0–2"/0–50mm
LCD Resolution .0001"/0.001mm
Accuracy (20°C) .00012" .00016"
Measuring force 1.5N or less 1.8N or less 2.3N or less
R-36
R-037 (2003) full size 12/9/03 12:46 PM Page 1
DIGIMATIC INDICATORS
R-37
R-038 (2003) full size 12/9/03 12:46 PM Page 1
DIGIMATIC INDICATORS
Series 543
Y
OG
EC
H N OL
T
Features
• Peak hold: Displays the max. or min. value during mea-
surement.
• Runout(TIR): Displays a runout(max.value-min.value)
during TIR measurement.
• It is possible to set the tolerance for TIR,Max,Min value.
• Absolute Encoder ensures the measurement origin is
maintained for the life of the battery.
543-262
• Resistant to overspeed error.
1.15"
Standard Accessories (Included)
Operation manual: 99MAH004B1
Batteries: SR44 (541980), 2pcs.
+/-
Optional Accessories
ZERO/ABS ON/OFF in/mm
Order No.
PRESET
SET MODE
R-38
R-039 (2003) full size 12/9/03 12:47 PM Page 1
DIGIMATIC INDICATORS
AB
• Capable of holding the minimum value.
Y
• Capable of tolerance judgment for the minimum value.
OG
EC
H N OL
T
• The analog bar shows the minimum value, upper/lower
limit values (in tolerance judgment) and the current
value.
• Capable of presetting 3 reference values (master val-
ues), and setting a corresponding tolerance value for
each.
• A data processor can be connected.
ON/OFF
Ø2.13" (Ø54)
M/W
2.38" (Ø60.5)
M1
M2
M3
DATA/HOLD START
1.83" (46.5)
2.14" (54.4)
PRESET TOL.
16.5
Thread Size
4–48 UNF
Ø3/8"
Specifications
Inch/Metric–Series 543 IDC-CG Type Digimatic Indicators with Absolute Encoder for Bore Gages
Order No. 543-266B 543-267B 543-264B
Model No. ID-C112GE ID-C112G ID-C112G
Resolution .00005"/0.001mm .0001"/0.001mm 0.001mm
Measuring range 0–.5"/0–12.7mm 0-12mm
Accuracy (20°C) .00012"/0.003mm 0.003mm
Quantizing error ± 1 count
Stem diameter ø3/8"DIA. ø8mm
Contact Point 4-48UNF M2.5x0.45
Protection level*1 IP-42
Measuring force 1.5N (150gf) or less
Battery Silver oxide cell (SR-44), 2 pcs. 541980
Battery life 9 months under normal use
Sampling frequency*2 50 times/s
Operating temperature 0°C to 40°C
Storage temperature -10°C to 60°C
Mass of main unit Approx. .35lbs/160g
For SPC output order connecting cable 905338 (1m) or 905409 (2m).
*1. Protection level (IP=International Protection) according to IEC 529/JIS D0207. C0920.
The level indicated is valid only if the output connector cap is installed.
*2. If the spindle detecting speed is over 50µm/s, the peak value may not be displayed correctly.
Accuracy is not including quantizing error.
R-39
R-040 (2003) full size 12/9/03 12:47 PM Page 1
DIGIMATIC INDICATORS
AB
Features
Y
• Compact and economical design.
OG
EC
H N OL
T
• Provided with a data output port for connection with the
SPC system.
• Power supply: One SR-44 battery (541980)
• Operating temperature: 0°C–40°C
• Membrane sealed face helps keep out contaminants.
Functions
• ON/OFF
• Origin setting
• Data output
• Inch/mm conversion (for Inch/Metric models)
• ± direction changeover
• Error alarm
575-123 • Low battery alarm
Specifications
Inch/Metric–IDU Digimatic Indicator with Absolute Encoder
575-123 575-121
Order No. (INCH/METRIC MODEL) (METRIC MODEL)
Measuring range 0–1"/0–25.4mm 0–25mm
LCD Resolution .0005"/0.01mm 0.01mm
Accuracy .0008" 0.02mm
.91" 1.50"
(23) (38) Quantizing error ± 1 count
Measuring Force (Downward) 1.8N or less
0 0
Stem Diameter .375 8.0mm
–.0012" –0.009mm
Data output Digimatic output
8.12" (207.3)
REV IN MIN
Standard Accessories
H
Silver-oxide cell SR-44 1pc (541980)
Protection Level IP-42
4.96"
ORIGIN ON/OFF
0
Optional Accessories
(Ø8 )
-0.009
Order No. Remarks
.53" (14.3)
R-40
R-041 (2003) full size 12/9/03 12:48 PM Page 1
DIGIMATIC INDICATORS
Features
• Large, backlit LCD which changes color from green to
red to indicate measurements out of set tolerance
(GO/±NG).
• Analog bar display with adjustable range and tolerance
indicators. Ideal for process monitoring such as zero/tol-
erance zone approach.
• Preset
• Max./Min. Hold mode.
• TIR Function.
• Zero-Set for comparison measurements.
• Selectable resolutions.
• ± Direction.
• Function Lock (prevents unintended changes).
543-558A • SPC Digimatic output.
• External Power Supply.
• Inch/Metric
543-552A
Specifications
Inch/Metric–Series 543 IDF Digimatic Indicators with Absolute Encoder and Color Changing LCD
Order No. 543-551A 543-557A 543-552A 543-558A
Measuring Range 0–25mm 0–50mm 0–1.0"/0–25mm 0–2.0"/0–50.8mm
LCD Resolution 0.001mm or 0.01mm .00005"/.0005"/.0001"/.001"/0.001mm/0.01mm
Accuracy (20°C) 0.003mm .00012"/0.003mm
Quantizing Error ± 1 count
Measuring Force 1.8N or less 2.3N or less 1.8N or less 2.3N or less
Stem (Dia.) 8mm 3/8" (.375")
Contact Point 3mm (Dia.) Carbide Ball (M2.5x0.45mm) 901312 .16" (Dia.) Steel Ball (4-48UNF) 900032
Power Supply AC Adapter (9V DC, 500mA) No.526688A
Data output SPC Digimatic output
ZERO/ABS, PRESET, MAX./MIN. HOLD, TIR, Selectable Resolution, Digital/Analog Display,
Functions
Key Lock, +/- Direction, GO/NG Judgment
Weight .53 lbs. .73 lbs. .53 lbs. .73 lbs.
Optional Accessories: SPC Cable No.936937 (1m), No.965014 (2m)
Lug-on-center Back No.101040 (Metric Model)
Lug-on-center Back No.101306 (Inch Model)
Accuracy is not including quantizing error
R-41
R-042 (2003) full size 12/9/03 12:48 PM Page 1
DIGIMATIC INDICATORS
2.60
1.70 1.70 .77
.77 .43
.43 2.60
3.35
∆ DATA OUT DC N
∆ DATA OUT DC N
2.22
in/mm +/-
in/mm +/-
3.28
3.30
4.32
2.67
3.74
SET ADJ
3.30
.68
3/8" (DIA)
(8mm DIA) 3/8" (DIA)
.68
Metric Model (8mm DIA)
1.66
Metric Model
1.02
2.05
2.62
Unit: Inch
6 5 4 3 2
10 11 12 13 14
R-42
R-043 (2003) full size 12/9/03 12:49 PM Page 1
R-43
R-044 (2003) full size 12/9/03 12:50 PM Page 1
Jog-dial
(DATA) button (CANCEL) button
i-Pak (Software)
Item Contents
Supporting industrial standard*1 ISO, JIS, JMAS, DIN, VDI/VDE/DGO, ANSI/ASME
Basic functions • Create an inspection standard conforming to the industrial standards.
• Create an original inspection standard, through customization industrial standard
• Inspect an indicator using a newly created inspection standard (inspection for accuracy, dispersion)
• Create and print of simplified inspection certificates.
• Display measurement results graphically.
Other functions Warning This window is displayed when the measured value exceeds the limit during the semiautomatic inspection
Re-measurement It is possible to confirm the measuring data, by re-measuring the specified position after the inspection
Display of inspection manual Display the inspection manual when starting an inspection*2
Retry Use for retry the "measurement positioning". (it removes the hysteresis of indicator automatically)
Password Restricted access through password registration
*1
refer to the reference materials (attached paper) for details about support for the industrial standards.
*2
To create an inspection manual, it is necessary to install the application software used to create the document, in the computer where i-pak is installed
Special Accessories
Code No. Description Code No. Description
1. Attachment 02ASK070 Stem Bush Dia. 15
02ASK000 Test Indicator Accessories Set (Dia. 6 Stem) 02ASK080 Stem Bush Dia. 20
02ASK180 Test Indicator Accessories Set (Dia. 8 Stem) 02ASK090 Stem Bush 3/8E
02ASK370 Test Indicator Holder (Dia. 6 Stem) 02ASK130 Case for Stem Bush
02ASK380 Test Indicator Holder (Dia. 8 Stem) 3. Others
02ASK110 Cylinder Gage Accessories Set 937179T Foot Switch
902803 Dia. 6 Stem with groove 02ASK730 Reflective Mirror
902804 Dia. 8 Stem with groove 4. Connecting Cable
2. Stem Bush 905338 SPC Cable (1m) *1 (ID-C, ID-S, ID-U, IDU)
02ASK040 Stem Bush Dia. 6 905409 SPC Cable (2m) *1 (ID-C, ID-S, ID-U, IDU)
02ASJ856 Stem Bush Dia. 8 936937 SPC Cable (1m) *1 (ID-F, IDF)
02ASK150 Stem Bush Dia. 8 (Short Size) 965014 SPC Cable (2m) *1 (ID-F, IDF)
02ASK050 Bush ø9.5 (Requires 02ASK070) 937387 SPC Cable (1m) *1 (ID-C, IDA)
02ASK060 Stem Bush Dia. 12 965013 SPC Cable (2m) *1 (ID-C, IDA)
*1
Use the cable of specification described in the manual to the digimatic indicator and counter.
R-44
R-045 (2003) full size 12/9/03 12:51 PM Page 1
Calibration Testers
Series 521
The Calibration Tester is specially designed to calibrate
continuous indicating accuracy of short range dial indi-
cators, test indicators, and other electronic comparison
gage heads. As the diagram shown on this page indi-
cates, the Calibration Tester employs a horizontal beam
which is pivoted at a 1 to 10 length ratio. Thus, a single
turn of the micrometer head creates one tenth of the
actual dimension at the anvil end. In this case, one com-
plete rotation of the head makes the beam move .025".
However, at the anvil top, this dimension will be convert-
ed to .0025".
The Calibration Tester can be used with various types
of measuring instruments. Some of the most common
applications include: Mu-Checker Cartridge Heads,
Lever Heads, Dial & Digimatic Indicators as well as Test 521-106 Shown mounted on Dial Indicator
Indicators.
Specifications
Calibration Tester
Inch
Measuring Indicating
Order No. Range Graduation Accuracy Mass Dimensions (W x D x H)
521-104 0–.05" .00001" ±.00001" 15.4 lbs. 11.6" x 4" x 8.1"
521-106 0–.2" .00001" ±.00003" 16.5 lbs. 11.6" x 4" x 10.9"
Metric
Measuring Indicating
Order No. Range Graduation Accuracy Mass Dimensions (W x D x H)
521-103 0–1mm 0.0002mm ±0.0002mm 15.4 lbs. 11.6" x 4" x 8.1"
521-105 0–5mm 0.0002mm ±0.0008mm 16.5 lbs. 11.6" x 4" x 10.9"
Stem holding capacity .157" to .394" (DIA). Dual-directional graduations on micrometer head. Supplied with fitted carrying case.
Specifications
Dial Gage Tester
Inch
Attachment 170-101E
Order No. Range Graduation Diameter Weight
170-101E 0–1" .0001" 1/4", 3/8" 15.4 lbs.
Supplied without Dial Indicator.
Metric
Attachment
Order No. Range Graduation Diameter Weight Optional Accessories
170-102M-2 0–25mm 0.001mm 6mm, 8mm 15.4 lbs. 951498 Optional stand for Dial Bore Gage inspection
With holder bar, for Dial Bore Gages and adjustable mirror.
R-45
R-046 (2003) full size 12/9/03 12:52 PM Page 1
SELECTION GUIDE
Dial Indicators
Group 0/1/2/3/4
NOMINAL BEZEL DIAMETER
.75 AD Note: Travel of spindle equals a minimum
INDICATING BEZEL
HAND CLAMP
CASE
of 2-1/2 turns if hand in all groups AD
BEZEL
BEZEL DIA.
CRYSTAL MOUNTING
LUG .25 THICK AD
MITUTOYO Series
.25 AD
AGD Series
Mil Specs.
.25AD
B (MIN POSITION) AD
Minimum
To and Position
Above including B
.31 AD 0 0 0 1" 1-3/8" 1-9/32"
MIN. DISTANCE FROM 1 1 1 1-3/8" 2" 1-5/8"
DIAL CENTER OF HOLE TO
STEM NEAREST PROJECTION
2 2 2 2" 2-3/8" 2"
FACE
SPINDLE .375 AD ON BACK 3 3 3 2-3/8" 3" 2-1/8"
4 4 4 3" 3-3/4" 2-9/16"
4.48 THREAD AD
TRAVEL .25 AD
REMOVABLE
CONTACT POINT
AD means American Gage Design Specification
Specifications
Mitutoyo offers dial indicators in four d. Hand Position – the indicating hand c. Accuracy (calibration) – a minimum
basic AGD Groups, with inch and metric shall be set at the approximate of 8 points, in equal increments over
graduations. These instruments conform 9 o'clock position when the spindle the range shall be calibrated (inward
to the three specifications governing dial is fully extended. and outward deflections without
indicators, highlights of which follow. e. Smallest graduation – inch: .00005", resetting the indicator dial).
In addition to the AGD Groups of dial .0001", .0005" and .001". Metric: d. Repeatability (check points) – shall
indicators, MITUTOYO offers “Hicators” 0.001mm, 0.002mm, 0.005mm and be checked for repetition of readings
which are ultra-sensitive, high- 0.01mm. at points approximately 25, 50 and
magnification indicators, reading in f. Dial Numbering – inch: dial numbers 75 percent of the full range.
50 millionths directly on the dial face. shall always indicate thousandths of e. Durability – the indicator shall show
American Gage Design (AGD) an inch regardless of magnification. no signs of significant wear or failure
To standardize minimum essential Metric: dial numbers shall always subsequent to 500,000 full scale
requirements for precision dial indicate hundredths of a millimeter. deflections.
indicators, AGD Specifications were Military Specifications (A-A-2348) f. Contact pressure – maximum force
introduced in 1945 as a Commercial The MIL Specifications, approved by the to deflect spindle was set forth on
Standard. Department of Defense, incorporate all types of dial and test indicators
They provide standards of performance most AGD specifications, and set forth to indicate sensitivity requirements.
and basic exterior dimensions in order test procedures for the determination of ANSI Specifications (ANSI B89.1.10)
to permit interchangeability. Following repeatability, accuracy and durability. Most recent specifications now proposed
is a digest of the specifications. Some of the highlights are: by the American National Standard
a. Repeatability – within plus or minus a. Repeatability – within plus or minus Institute for mutual understanding
one-fifth graduation at any point. one-fifth graduation and before and between manufacturers and users. The
b. Accuracy – shall be accurate to after 500,000 deflections. basic contents confirm AGD and MIL
within one graduation, plus or minus, specifications. However, it proposes the
b. Accuracy – shall be accurate to following:
at any point (2-1/3 turns). within one graduation, plus or minus,
c. Spindle Range – the range of spindle at any point (2-1/3 turns). a. Metric dial face shall be yellow.
travel should be a minimum of 2-1/2 b. Graduations Inch: .00005", .0001",
revolutions of the indicating hand. Mitutoyo Indicators meet All .0005" and .001". Metric: 0.001mm,
Specifications 0.002mm, 0.01mm and 0.02mm
(0.005mm graduation recognized by
(with the exception of 8mm stem models).
AGD was eliminated).
R-46
R-047 (2003) full size 12/9/03 12:52 PM Page 1
SELECTION GUIDE
10
20 0 10
MADE IN 20
3020 30
10
_ 0
20 +
10
MADE .001"— 250"
30 30
NO. 1411
_ 0 +
.001"— 250"
5 5
20 20
3
30 30
NO. 1411
40
2 .001"— 250"
3040
40
10
0 1
.001
10 30 .001"— 250"
NO. 1411
40
NO. 1921
40
40 40
NO. 1411
40 50 50
15
20
15
50 50
30
.0005"
10
5 Types of Dial Faces 10
.0005"
10
NO. 2670-08 ® NO. 2922-08 ®
2
1 0
SHOCK PROOF
15 1
2 3
SHOCK PROOF
15
3 0
25 15 20 20
20 25
_ 0 +
10 10
Continuous Reversed balanced
20 20
30 30
_ 0 + 0
5 5
.001"
NO. 2608-63 10 90
40 SHOCK PROOF 40
.0005"
10 10 20
.001"
80
15 1 0
NO. 2907-08
SHOCK PROOF
®
15
One revolution 30
0
NO. 2904 ®
70
SHOCK PROOF
9 1
2 8 2
3 7 3
6 4
5
20 20 40 60
25 50
R-47
R-048 (2003) full size 12/9/03 12:53 PM Page 1
SELECTION GUIDE
2044B-61
Model Number "First Suffix"
The Letter Suffix: The Two Number 2910-72 – “7” indicates ND-type with
both Waterproof and Jeweled Bearings.
Unless otherwise specified, the Dial
Indicator will be supplied with a
Suffix: 2805F-80 – “8” indicates that the
After the hyphen (-), the two numbers indicator is furnished with Spindle
Lug-on-Center Back. Otherwise, the fol-
that follow it have specific meanings. Stop feature.
lowing suffixes will appear immediately
Consequently, we have a First Suffix or Second Suffix – The last number of the
after the model number. Please specify
the features designated by the first two digit suffix.
when ordering.
numerals of this double digit figure
2044B – the “B” letter means Flat Back 2109-11 – “1” indicates that this is a
and the Second Suffix which further
instead of Lug-on-Center back. Metric indicator, ANSI specification.
specifies the indicator feature.
2047F – the “F” letter indicates an 2910-72 – “2” indicates that the
First Suffix – The First number of the
indicator supplied with Mitutoyo’s indicator has Shockproof and Dust
two digit suffix.
new-type Flat Crystal which has one Proof features.
2947-10 – “1” indicates that the
piece Bezel and Crystal. For moisture 2900-73 – “3” indicates a Metric
indicator has Jeweled Bearings.
resistance, metric models have a indicator, ANSI specs, with Shockproof
groove at the stem bottom. 2945-40 – “4” indicates that the indica- and Dust Proof features.
tor is “ND-type”, an indicator with a
2046FE – the “FE” letter indicates new 2410F-06 – “6“ indicates black dial
modified integral gear assembly.
type Flat Crystal (metric model only). face with orange hands.
2470-50 – “5” indicates an ND-type
2046-69 – “9” indicates that the
(same as above) with Jeweled Bearing.
indicator is furnished with Shockproof
2410-60 – “6” indicates with mechanism.
Waterproof feature.
Metric Model
Has Groove
at Stem Bottom
R-48
R-049 (2003) full size 12/9/03 12:53 PM Page 1
SELECTION GUIDE
R-49
R-050 (2003) full size 12/9/03 12:54 PM Page 1
SELECTION GUIDE
R-50
R-051 (2003) full size 12/9/03 12:54 PM Page 1
SELECTION GUIDE
R-51
R-052 (2003) full size 12/9/03 12:55 PM Page 1
SELECTION GUIDE
R-52
R-053,54,55 (2003) full size 12/9/03 12:56 PM Page 1
SELECTION GUIDE
1003 0.01mm 1mm 4mm 0-50-0 1923 .0005" .02" .05" 0-10-0
1010-11 0.002mm 0.2mm 0.5mm 0-20 1925-10 .0001" .01" .025" 0-5-0
1011-11 0.002mm 0.2mm 0.5mm 0-10-0 1927-10 .0001" .004" .01" 0-2-0
1013F 0.002mm 0.2mm 1mm 0-100-0 1929F 0.01mm 1mm 50-0-50
1040F 0.01mm 0.5mm 3.5mm 0-50 1929F-60 0.01mm 1mm 50-0-50
1041F 0.01mm 0.5mm 3.5mm 0-25-0 1929F-62 0.01mm 1mm 50-0-50
1044-01 0.01mm 1mm 5mm 0-100 1960 0.01mm ± 0.5mm 50-0-50
1044F 0.01mm 1mm 5mm 0-100 1961 .001 ± .02 20-0-20
1044F-10 0.01mm 1mm 5mm 0-100 2010F-11 0.002mm 0.2mm 0.5mm 0-20
1044F-60 0.01mm 1mm 5mm 0-100 2010F-61 0.002mm 0.2mm 0.5mm 0-20
1045-01 0.01mm 1mm 5mm 0-50-0 2011F-11 0.002mm 0.2mm 0.5mm 0-10-0
1045F 0.01mm 1mm 5mm 0-50-0 2011F-61 0.002mm 0.2mm 0.5mm 0-10-0
1109F 0.001mm 0.2mm 1mm 0-100-0 2032F-11 0.02mm 2mm 5mm 0-200
1124F 0.005mm 0.5mm 3.5mm 0-50 2033F-11 0.02mm 2mm 5mm 0-100-0
1156 .001" .1" .1" 0-100 2044F 0.01mm 1mm 5mm 0-100
1157 .001" .1" .1" 0-50-0 2044F-01 0.01mm 1mm 5mm 0-100
1158 0.02mm 2.6mm 2.6mm 0-260 2044F-60 0.01mm 1mm 5mm 0-100
1159 0.02mm 2.6mm 2.6mm 0-130-10 2044F-61 0.01mm 1mm 5mm 0-100
1160 0.01mm 1mm 5mm 0-100 2044FE-09 0.01mm 1mm 5mm 0-100
1166 .001" .05" .2" 0-50 2045F-01 0.01mm 1mm 5mm 0-50-0
1167 .001" .05" .2" 0-25-0 2045FE 0.01mm 1mm 5mm 0-50-0
1168 .001" .05" .2" 50-0 2045F-60 0.01mm 1mm 5mm 0-50-0
1230-01 0.01mm 1mm 2.5mm 0-100 2045F-61 0.01mm 1mm 5mm 0-50-0
1231-01 0.01mm 1mm 2.5mm 0-50-0 2046F 0.01mm 1mm 10mm 0-100
1400-10 .001" .02" .05" 0-20 2046F-01 0.01mm 1mm 10mm 0-100
1401-10 .001" .02" .05" 0-10-0 2046F-11 0.01mm 1mm 10mm 0-100
1404-10 .001" .04" .1" 0-40 2046F-60 0.01mm 1mm 10mm 0-100
1405-10 .001" .04" .1" 0-20-0 2046F-61 0.01mm 1mm 10mm 0-100
1410 .001" .1" .25" 0-100 2046F-69 0.01mm 1mm 10mm 0-100
1410-10 .001" .1" .25" 0-100 2046FE 0.01mm 1mm 10mm 0-100
1411 .001" .1" .25" 0-50-0 2046FE-09 0.01mm 1mm 10mm 0-100
1470 .00025" .02" .05" 0-20 2046FE-10 0.01mm 1mm 10mm 0-100
1470-10 .00025" .02" .05" 0-20 2047F-01 0.01mm 1mm 10mm 0-50-0
1471 .00025" .02" .05" 0-10-0 2047F-11 0.01mm 1mm 10mm 0-50-0
1476 .00025" .02" .2" 0-20 2047FE 0.01mm 1mm 10mm 0-50-0
1506 .0005" .05" .125" 0-50 2048F-01 0.01mm 1mm 10mm 0-100
1507 .0005" .05" .125" 0-25-0 2048FE-10 0.01mm 1mm 10mm 0-100
1507-10 .0005" .05" .125" 0-25-0 2048F-11 0.01mm 1mm 10mm 0-100
1570-10 .0005" .03" .075" 0-30 2050F-01 0.01mm 1mm 20mm 0-100
1571-10 .0005" .03" .075" 0-15-0 2050FE-10 0.01mm 1mm 20mm 0-100
1580-10 .001" .03" .075" 0-30 2050F-11 0.01mm 1mm 20mm 0-100
1581-10 .001" .03" .075" 0-15-0 2050F-60 0.01mm 1mm 20mm 0-100
1670 .0005" .04" .1" 0-40 2050FE 0.01mm 1mm 20mm 0-100
1671 .0005" .04" .1" 0-20-0 2052FE 0.01mm 1mm 30mm 0-100
1671-10 .0005" .04" .1" 0-20-0 2052FE-10 0.01mm 1mm 30mm 0-100
1780 .001" .05" .125" 0-50 2056F-01 0.01mm 1mm 25mm 0-100
1781 .001" .05" .125" 0-25-0 2109F 0.001mm 0.2mm 1mm 0-100-0
1781-10 .001" .05" .125" 0-25-0 2109F-11 0.001mm 0.2mm 1mm 0-100-0
1802-10 .0001" .01" .025" 0-10 2109F-60 0.001mm 0.2mm 1mm 0-100-0
1803-10 .0001" .01" .025" 0-5-0 2110F 0.001mm 0.1mm 1mm 0-100
1900F-62 0.001mm 0.1mm 50-0-50 2110F-60 0.001mm 0.1mm 1mm 0-100
1909-62 .0005" .04" 20-0-20 2113F 0.001mm 0.2mm 2mm 0-100-0
1910-72 .0001" .006" 3-0-3 2118F 0.001mm 0.2mm 5mm 0-100-100
1911 0.01mm 1mm 2.5mm 0-50-0 2119F 0.001mm 0.2mm 5mm 0-100-0
1913-10 0.002mm 0.2mm 0.5mm 0-100-0 2119-51 0.001mm 0.2mm 5mm 0-10-0
1921 .001" .04" .1" 0-20-0 2120F-11 0.005mm 0.5mm 1.25mm 0-50
R-53
R-053,54,55 (2003) full size 12/9/03 12:57 PM Page 2
SELECTION GUIDE
2120-71 0.005mm 0.5mm 1.25mm 0-50 2571F-10 .0005" .03" .075" 0-15-0
2121F-11 0.005mm 0.5mm 1.25mm 0-25-0 2571F-60 .0005" .03" .075" 0-15-0
2121-71 0.005mm 0.5mm 1.25mm 0-25-0 2576F-60 .0005" .03" .3" 0-30
2124F 0.005mm 0.5mm 5mm 0-50 2600F-10 .00025" .01" .025" 0-10
2204F .01" 1" 1" 0-1000 2601F-10 .00025" .01" .025" 0-5-0
2230F-01 0.01mm 1mm 2.5mm 0-100 2670F .0005" .04" .1" 0-40
2230F-11 0.01mm 1mm 2.5mm 0-100 2670F-10 .0005" .04" .1" 0-40
2231F-01 0.01mm 1mm 2.5mm 0-50-0 2671F .0005" .04" .1" 0-20-0
2231F-11 0.01mm 1mm 2.5mm 0-50-0 2671F-10 .0005" .04" .1" 0-20-0
2310FE 0.01mm 1mm 10mm 0-100 2675F .0005" .04" .4" 0-20-0
2320FE 0.01mm 1mm 20mm 0-100 2776F .0005" .05" 1" 0-50
2330FE 0.01mm 1mm 30mm 0-100 2776F-60 .0005" .05" 1" 0-50
2356-50 .0001" .01" .25" 0-10 2780F .001" .05" .125" 0-50
2358-50 .0001" .01" .5" 0-10 2780F-10 .001" .05" .125" 0-50
2400F-10 .001" .02" .05" 0-20 2781F .001" .05" .125" 0-25-0
2401F-10 .001" .02" .05" 0-10-0 2781F-10 .001" .05" .125" 0-25-0
2404F-10 .001" .04" .1" 0-40 2802F-10 .0001" .01" .025" 0-10
2405F-10 .001" .04" .1" 0-20-0 2802F-60 .0001" .01" .025" 0-10
2410F .001" .1" .25" 0-100 2803F-10 .0001" .01" .025" 0-5-0
2410F-06 .001" .1" .25" 0-100 2803F-60 .0001" .01" .025" 0-5-0
2410F-10 .001" .1" .25" 0-100 2804F-10 .0001" .01" .05" 0-10
2410F-60 .001" .1" .25" 0-100 2805F-10 .0001" .01" .05" 0-5-0
2411F .001" .1" .25" 0-50-0 2805F-80 .0001" .01" .05" 0-5-0
2411F-10 .001" .1" .25" 0-50-0 2806F-10 .0001" .01" .1" 0-10
2412F .001" .1" .4" 0-100 2806F-60 .0001" .01" .1" 0-10
2412F-60 .001" .1" .4" 0-100 2900-73 0.001mm 0.1mm 50-0-50
2412F-80 .001" .1" .4" 0-100 2900F 0.001mm 0.14mm 0.1mm 50-0-50
2413F .001" .1" .4" 0-50-0 2900F-62 0.001mm 0.14mm 0.1mm 50-0-50
2414F .001" .1" .5" 0-100 2901F 0.001mm 0.2mm 0.16mm 80-0-80
2414F-06 .001" .1" .5" 0-100 2902F-01 0.01mm 1mm 10mm 100-0
2414F-10 .001" .1" .5" 0-100 2902FE 0.01mm 1mm 10mm 100-0
2414F-60 .001" .1" .5" 0-100 2903F .001" .1" .4" 100-0
2415F .001" .1" .5" 0-50-0 2904F .001" .1" 1" 100-0
2415F-10 .001" .1" .5" 0-50-0 2905F-10 .0001" .01" .05" 10-0
2415F-60 .001" .1" .5" 0-50-0 2906F .0005" .05" .125" 50-0
2416F .001" .1" 1" 0-100 2908-62 .001" .08" 40-0-40
2416F-06 .001" .1" 1" 0-100 2909-62 .0005" .04" 20-0-20
2416F-10 .001" .1" 1" 0-100 2910-72 .0001" .008" 4-0-4
2416F-60 .001" .1" 1" 0-100 2915F-10 .001" .1" .5" 0-100
2417F .001" .1" 1" 0-50-0 2918F-10 .001" .1" .5" 0-50-0
2424-10 .001" .1" 2" 0-100 2919F-10 .001" .1" .25" 0-100
2470-50 .00025" .02" .05" 0-20 2920F-10 .001" .1" .25" 0-50-0
2471-50 .00025" .02" .05" 0-10-0 2922F .0005" .05" .125" 0-25-0
2476F-60 .00025" .02" .24" 0-20 2923F-10 .0001" .01" .05" 0-5-0
2500F-10 .0005" .02" .05" 0-20 2928F 0.01mm 0.4mm 4mm 2-0-2
2501F-10 .0005" .02" .05" 0-10-0 2929F 0.01mm 1mm 50-0-50
2506F .0005" .05" .125" 0-50 2929-62 0.01mm 1mm 50-0-50
2506F-10 .0005" .05" .125" 0-50 2937F-10 .0001" .008" .02" 0-4-0
2507F .0005" .05" .125" 0-25-0 2938F-10 .0001" .008" .02" 0-8
2507F-10 .0005" .05" .125" 0-25-0 2945-40 .001" .08" 40-0-40
2514F .0005" .05" .5" 0-50 2947F-10 .0001" .008" 4-0-4
2514F-60 .0005" .05" .5" 0-50 2952FE 0.01mm 1mm 30mm 100-0
2570F .0005" .03" .075" 0-30 2959F 0.01mm 1.6mm 80-0-80
2570F-10 .0005" .03" .075" 0-30 2960 0.01mm ± 0.5mm 50-0-50
2570F-60 .0005" .03" .075" 0-30 2961 .0005" .04" 20-0-20
2571F .0005" .03" .075" 0-15-0 2971 0.01mm 0.5mm 25-0-25
R-54
R-053,54,55 (2003) full size 12/9/03 12:57 PM Page 3
SELECTION GUIDE
R-55
R-056 (2003) full size 12/9/03 1:00 PM Page 1
DIAL INDICATORS/INCH
80 MADE IN JAPAN
40 40
90 100 90 50
Thickness .25" Thickness 5
1913-10 1911
1.18"
.63"
ø31
ø1.22
16
30
_ 0 + _ 0 +
0 1 0 1
.5 .5
.59"
0 0
ø.375" ø8
15
1 1
A
-.001 -0.009 3
2
3 2 2 2
1 JEWELED
1
.0001" .0001"
3 3
B
1923 1921
High Precision Type Reverse Reading Balanced Dial Continuous Dial One Revolution
Damper at Lowest Rest Point Shockproof Adjustable Hand Waterproof Double Scale Spacing
Coaxial Revolution Counter Peak Retaining Long Stem Dustproof Jeweled Low Force
R-56
R-057 (2003) full size 12/9/03 1:05 PM Page 1
DIAL INDICATORS/INCH
Dial Indicators
Specifications
Inch–ANSI Standard (Stem Diameter 3/8")
Total Range Dial Accuracy
Graduation Range Order No. Per Rev. Reading 2-1/3 Rev. Total Range Features
.0001" .025" 1802F-10 .01" 0-10 ±.0001" ±.0002"
1803F-10 .01" 0-5-0 ±.0001" ±.0002"
.00025" .05" 1470F .02" 0-20 ±.00025" ±.00025"
1470F-10 .02" 0-20 ±.00025" ±.00025"
1471F .02" 0-10-0 ±.00025" ±.00025"
.2" 1476F .02" 0-20 ±.00025" ±.0005"
.0005" .075" 1570F-10 .03" 0-30 ±.0005" ±.0005"
1571F-10 .03" 0-15-0 ±.0005" ±.0005"
.1" 1670F .04" 0-40 ±.0005" ±.0005"
1671F .04" 0-20-0 ±.0005" ±.0005"
1671F-10 .04" 0-20-0 ±.0005" ±.0005"
1411F .125" 1506F .05" 0-50 ±.0005" ±.0005"
1507F .05" 0-25-0 ±.0005" ±.0005"
1507F-10 .05" 0-25-0 ±.0005" ±.0005"
.001" .05" 1400F-10 .02" 0-20 ±.0005" ±.001"
1401F-10 .02" 0-10-0 ±.0005" ±.001"
.075" 1580F-10 .03" 0-30 ±.0005" ±.001"
1581F-10 .03" 0-15-0 ±.0005" ±.001"
.1" 1404F-10 .04" 0-40 ±.0005" ±.001"
1405F-10 .04" 0-20-0 ±.0005" ±.001"
.125" 1780F .05" 0-50 ±.001" ±.001"
1781F .05" 0-25-0 ±.001" ±.001"
1781F-10 .05" 0-25-0 ±.001" ±.001"
.25" 1410F .1" 0-100 ±.001" ±.001"
1410F-10 .1" 0-100 ±.001" ±.001"
1411F .1" 0-50-0 ±.001" ±.001"
The measuring force for all of the above indicators is 1.4N or less.
The conversion factor between Newton force and gram force is 1N=101.94gf.
Lug back is standard; for flat-back version add ‘B’ to the order number, e.g. 1802B-10.
High Precision Type Reverse Reading Balanced Dial Continuous Dial One Revolution
Damper at Lowest Rest Point Shockproof Adjustable Hand Waterproof Double Scale Spacing
Coaxial Revolution Counter Peak Retaining Long Stem Dustproof Jeweled Low Force
R-57
R-058 (2003) full size 12/9/03 1:16 PM Page 1
DIAL INDICATORS/INCH
Dimensions
Order No. A B C ø.31"
ø.26"
C
1803F-10 1.65” .31” 1.09”
1470 1.69” .36” 1.09”
ø1.61"
1470-10 1.69” .36” 1.09”
1.50"
.63"
1471 1.69” .36” 1.09”
1476 1.91” .59” 1.28” .25"
1570F-10 1.71” .38” 1.09”
.53"
0
ø.375"
1571F-10 1.71” .38” 1.09” -.001
B
1671 1.73” .40” 1.27”
1671-10 1.73” .40” 1.27” .26"
1506F 1.77” .44” 1.09”
1507F 1.77” .44” 1.09”
Unit: Inch (mm)
1507-10 1.77” .44” 1.09”
1400-10 1.65” .36” 1.09”
1401-10 1.65” .36” 1.09”
1580-10 1.71” .38” 1.09”
1581-10 1.71” .38” 1.09”
1404F-10 1.73” .40” 1.27”
1405F-10 1.73” .40” 1.27”
1780 1.77” .44” 1.09”
1781 1.77” .44” 1.09”
1781-10 1.77” .44” 1.09”
1410F 1.89” .56” 1.27”
1410-10 1.89” .56” 1.27”
1411F 1.89” .56” 1.27”
_ 0 + 19 0 1 _ 0 + _ 0 +
1 1 18 2
17 5 5
0 0 3 5
3
5
1 1 2
2 2 3 2 16 2 3 4 0 1 .0005"
.0001"
15 .00025 5 .0005"
10 10
NO.1671
3 3 14 6 3 2
1
NO.1803-10 ®
13 NO.1470 ®
7 10 NO.1571-10 ® 10 0
15 15
JEWELED JEWELED
4 4 12 8
5 11 10 9 15 20
0 _ 0 + 0 _ 0 +
45 5 5 5 90 10 10 10
R-58
R-059 (2003) full size 12/9/03 1:16 PM Page 1
DIAL INDICATORS/INCH
Specifications
Metric–ANSI Standard (Stem Diameter 3/8" with yellow dial face)
Total Range Dial Accuracy
Graduation Range Order No. Per Rev. Reading 2-1/3 Rev. Total Range Features
0.002mm 0.5mm 1010-11 0.2mm 0-20 ±0.002mm
1011-11 0.2mm 0-10-0 ±0.002mm
0.01mm 2.5mm 1230-01 1mm 0-100 ±0.01mm
1231-01 1mm 0-50-0 ±0.01mm
5mm 1044-01 1mm 0-100 ±0.01mm ±0.013mm
1045-01 1mm 0-50-0 ±0.01mm ±0.013mm
High Precision Type Reverse Reading Balanced Dial Continuous Dial One Revolution
Damper at Lowest Rest Point Shockproof Adjustable Hand Waterproof Double Scale Spacing
Coaxial Revolution Counter Peak Retaining Long Stem Dustproof Jeweled Low Force
R-59
R-060 (2003) full size 12/9/03 1:17 PM Page 1
DIAL INDICATORS/METRIC
5.3
ø.26"
ø.31" Ø6.5
32.5
Ø6.5
13
20
C
16
ø1.61"
1.50"
.63"
Ø36
Ø41
5
5
39.5
.25" 0
Ø8 -0.009
A
9.5
.53"
0
A
0
ø.375"-.001 Ø8 -0.009
13
M2.5 x 0.45
12
#4-48 Threads
B
Unit: mm
B
M2.5x0.45
.26" Unit: Inch
Unit: mm
1003
Dimensions Dimensions
ANSI Standard Metric Standard Unit: mm
Order No. A B C Order No. A B
1010-11 1.62” .29” 1.51” 1109F 49 15.5
1011-11 1.62” .29” 1.51” 1013F 49 15.5
1230-01 1.73” .40” 1.27” 1124F 46 12.5
1231-01 1.73” .40” 1.27” 1040F 46 12.5
1044-01 1.85” .52” 1.27” 1041F 46 12.5
1045-01 1.85” .52” 1.27” 1044F 47.5 14
1044F-10 47.5 14
1044F-60 57 25
1045F 47.5 14
Dial Indicator Faces
Group 1 – Metric
_ 0 _ 0 +
1 0 +1 45 0
5 5 5 0
2 2 5 45
90 10
0
3 1
3
4
2 3
4
40 0.01mm 10 10 0.01mm
10 0.01mm
10 40 80 20
5 2µm 5 15 NO. 1040F ® 35 NO. 1041F ® NO.1230 ®
6 6 35 2 3 15 15 2 3 15 70 3 2 30
1 1 1
NO.1011
7 JEWELED
7 20
0
30
0 0
8 8 30 25 20 20 20 60 40
9 10 9 25 25 50
_ 0 + 0 _ 0 +
10 10 90
10
0
10
90 10 10
0.01mm 0.01mm
20 20 80 20 20 0.01mm
20
20 80
R-60
R-061 (2003) full size 12/9/03 1:19 PM Page 1
DIAL INDICATORS/INCH
High Precision Type Reverse Reading Balanced Dial Continuous Dial One Revolution
Damper at Lowest Rest Point Shockproof Adjustable Hand Waterproof Double Scale Spacing
Coaxial Revolution Counter Peak Retaining Long Stem Dustproof Jeweled Low Force
R-61
R-062 (2003) full size 12/9/03 1:20 PM Page 1
DIAL INDICATORS/INCH
High Precision Type Reverse Reading Balanced Dial Continuous Dial One Revolution
Damper at Lowest Rest Point Shockproof Adjustable Hand Waterproof Double Scale Spacing
Coaxial Revolution Counter Peak Retaining Long Stem Dustproof Jeweled Low Force
R-62
R-063 (2003) full size 12/9/03 1:21 PM Page 1
DIAL INDICATORS/INCH
_ 0 + _ 0 + _ 0 + 0 0
1 1 9 1 1 1 9 1 9 1
.0001" .0001" .0001" .0001"
.0001"
8 2 2 2 8 2 8 2
2 2 NO. 2358 - 50
NO. 2356- 50
NO. 2937F-10 ® JEWELED
1 0
6 JEWELS 6 6 JEWELS
9 JEWELED
3 3 7 3
JEWELS
7 3
0 0
7 3 0
SHOCK PROOF
0 1 1 2 8
1 0 .25 .05
2 2 2 .5 .1 3 7
3 3 .4 .2 4 5 6 .2 .1
3
3 3
.3 .15
6 4 4 4 6 4 6 4
4 5 5 5 5
19 0 1 _ 0 + _ 0 + _ 0 + 0
18 2 45 5 5 5
17 3
.00025" .0005" .0005" 5 .0005" 5 25 .0005"
5
16 4 40 10 10 10
15 NO. 2470 -50 ®
5
1 0 ®
14
JEWELED
6 35 15 15 15
SHOCK PROOF SHOCK PROOF
2
1 0
JEWELED JEWELED
3 1 0 1 0 1 0
2
13 7
2
3
2
3 10 3 10 20
2
3
10
12 8 30 20 20 20
11 10 9 25 25 15 15
_0 +
45
0
5
+ 0 _ 0
45
0
5
5 5
35 5 5 5
.0005" .0005" .001"
.0005"
40 10 10 10 .0005" 40 10
30 10 10 10
35
®
15
SHOCK PROOF SHOCK PROOF
35 0
15 15 15 1 0
SHOCK PROOF SHOCK PROOF
2 3 SHOCK PROOF
1 0
.1 .4 1 1 0 2
2 2
0 3
3 3
15 15 15
.2 .3
30 20 20 20 25 30 20
25 25 20 20 25
_ 0 + 0 _ 0 + 0
90
0
5 5 10 10 10 90
10
10
90
® NO. 2410F
NO. 2411F
15 15 70 30 30 30
SHOCK PROOF
0
1 0 0 0 30 1 9 70
2 70 2 8 30
1 3 1 3
3 3 7
4 6
2 2 5
20 20 60 40 40 40 40
60
60
40
25 50 50 50
50
0 0 0
0
10 90 90 10 90 10
10 90
.001"
20 80 80 JEWELED
20 80 2 0
2
0 20
20 .9 .1 .1 80
.9
.8 .2 .8 .2
.7 .3 .7 .3
NO. 2904F
0 .001" .6 .4 .6
30 8
9 1
2 70 70 NO. 2919-10 30 30
70 .5
.5
.6
NO. 2424-10
.001"
.4
.5
.5
.4 70
30
7 3
3 0 .4 .7
MADE IN JAPAN
.3 .6
.8 .2
.3 .9 1 .1 .7
6
5
4 2 1 .2 .8
.1 1 .9
40 60 60 40 60
40 60
40
50 50 50
50
R-63
R-064 (2003) full size 12/9/03 1:22 PM Page 1
DIAL INDICATORS/INCH
F .75"
Dial Indicators / Group 2
ø.26"
Inch .59 " .75"
(.69")
D
ø.26"
.63"
D
G
E
2.19" (2.28")
2.05" (2.13")
.63"
.25"
A
0
C
.375"-.001
.25"
B
#4-48 Threads
A
0
C
.375" -.001
Dimensions
B
#4-48 Threads
Order No. A B C D E F G H
2937F-10 2.07” .39” .59” 1.78” 2.19” .59” 2.05” .30”
.30"
2938F-10 2.07” .39” .59” 1.78” 2.19” .59” 2.05” .30”
2802F-10 2.07” .39” .59” 1.78” 2.19” .59” 2.05” .30”
2802F-60 2.15” .75” .31” 1.55” 2.19” .59” 2.05” .30”
2803F-10 2.07” .39” .59” 1.78” 2.19” .59” 2.05” .30” Dimensions
2803F-60 2.15” .75” .31” 1.55” 2.19” .59” 2.05” .30” Order No. A B C D
2804F-10 2.07” .39” .59” 1.78” 2.19” .59” 2.05” .30” 2400F-10 2.07” .39” .59” 1.78”
2805F-10 2.07” .39” .59” 1.78” 2.19” .59” 2.05” .30” 2401F-10 2.07” .39” .59” 1.78”
2805F-80* 2.07” .39” .59” 2.32” 2.19” .61” 2.05” .30” 2404F-10 2.12” .44” .59” 1.90”
2905F-10 2.07” .39” .59” 1.78” 2.19” .59” 2.05” .30” 2405F-10 2.12” .44” .59” 1.90”
2923F-10 2.07” .39” .59” 1.78” 2.19” .59” 2.05” .30” 2780F 2.15” .47” .59” 1.78”
2806F-10 2.14” .46” .59” 1.78” 2.19” .59” 2.05” .30” 2780F-10 2.15” .47” .59” 1.78”
2806F-60 2.15” .79” .27” 1.55” 2.19” .59” 2.05” .30” 2781F 2.15” .47” .59” 1.78”
2356-50 2.28” .61” .53” 1.84” 2.28” .69” 2.13” .35” 2781F-10 2.15” .47” .59” 1.78”
2358-50 2.52” .85” .53” 2.04” 2.28” .69” 2.13” .35” 2410F 2.30” .62” .59” 1.55”
2600F-10 2.07” .39” .59” 1.78” 2.19” .59” 2.05” .30” 2410F-10 2.30” .62” .59” 1.55”
2601F-10 2.07” .39” .59” 1.78” 2.19” .59” 2.05” .30” 2410F-60 2.30” .94” .27” 1.55”
2470-50 2.07” .40” .53” 1.84” 2.28” .69” 2.13” .35” 2919F-10* 2.51” .83” .59” 1.98”
2471-50 2.07” .40” .53” 1.84” 2.28” .69” 2.13” .35” 2411F 2.30” .62” .59” 1.55”
2476F-60 2.26” .89” .27” 1.78” 2.19” .59” 2.05” .30” 2411F-10 2.30” .62” .59” 1.55”
2500F-10 2.07” .39” .59” 1.78” 2.19” .59” 2.05” .30” 2920F-10 2.51” .83” .59” 1.98”
2501F-10 2.07” .39” .59” 1.78” 2.19” .59” 2.05” .30” 2412F* 2.45” .77” .59” 1.46”
2570F 2.11” .43” .59” 1.78” 2.19” .59” 2.05” .30” 2412F-60 2.45” 1.09” .27” 1.78”
2570F-10 2.11” .43” .59” 1.78” 2.19” .59” 2.05” .30” 2412F-80* 2.45” .77” .59” 2.32”
2570F-60 2.11” .74” .27” 1.78” 2.19” .59” 2.05” .30” 2413F* 2.45” .77” .59” 1.46”
2571F 2.11” .43” .59” 1.78” 2.19” .59” 2.05” .30” 2903F* 2.45” .77” .59” 1.46”
2571F-10 2.11” .43” .59” 1.78” 2.19” .59” 2.05” .30” 2414F* 2.56” .88” .59” 1.46”
2571F-60 2.11” .74” .27” 1.78” 2.19” .59” 2.05” .30” 2414F-10* 2.56” .88” .59” 1.46”
2576F-60 2.33” .97” .27” 1.78” 2.19” .59” 2.05” .30” 2414F-60 2.56” 1.20” .27” 1.78”
2670F 2.12” .44” .59” 1.90” 2.19” .59” 2.05” .30” 2915F-10* 2.51” .83” .59” 1.98”
2670F-10 2.12” .44” .59” 1.90” 2.19” .59” 2.05” .30” 2415F* 2.56” .88” .59” 1.46”
2671F 2.12” .44” .59” 1.90” 2.19” .59” 2.05” .30” 2415F-10* 2.56” .88” .59” 1.46”
2671F-10 2.12” .44” .59” 1.90” 2.19” .59” 2.05” .30” 2415F-60 2.56” 1.20” .27” 1.78”
2675F* 2.45” .77” .59” 1.46” 2.19” .59” 2.05” .30” 2918F-10* 2.51” .83” .59” 1.98”
2506F 2.15” .47” .59” 1.78” 2.19” .59” 2.05” .30” 2416F* 3.05” 1.37” .59” 1.46”
2506F-10 2.15” .47” .59” 1.78” 2.19” .59” 2.05” .30” 2416F-06* 3.05” 1.37” .59” 1.46”
2507F 2.15” .47” .59” 1.78” 2.19” .59” 2.05” .30” 2416F-10* 3.05” 1.37” .59” 1.46”
2507F-10 2.15” .47” .59” 1.78” 2.19” .59” 2.05” .30” 2416F-60* 3.18” 1.81” .27” 2.37”
2906F 2.15” .47” .59” 1.78” 2.19” .59” 2.05” .30” 2417F* 3.05” 1.37” .59” 1.46”
2922F 2.15” .47” .59” 1.78” 2.19” .59” 2.05” .30” 2904F* 3.05” 1.37” .59” 1.46”
2514F 2.55” .87” .59” 1.46” 2.19” .59” 2.05” .30” 2424-10 5.47” 2.33” 2.04” 4.67”
2514F-60 2.56” 1.20” .27” 1.78” 2.19” .59” 2.05” .30” 2204F* 3.05” 1.37” .59” 1.46”
2776F* 3.05” 1.37” .59” 1.46” 2.19” .59” 2.05” .30” *Denotes the indicator does not feature a cap (dimension ‘D’ is taken to the
2776F-60 3.18” 1.81” .27” 2.37” 2.19” .59” 2.05” .30” screw top, which rises with the spindle).
*Denotes the indicator does not feature a cap (dimension ‘D’ is taken to the
screw top, which rises with the spindle).
R-64
R-065 (2003) full size 12/9/03 1:22 PM Page 1
DIAL INDICATORS/METRIC
Specifications
Metric–ANSI Standard (Stem Diameter 3/8" with yellow dial face)
Total Range Dial Accuracy
Graduation Range Order No. Per Rev. Reading 2-1/3 Rev. Total Rev Features
0.001mm 1mm 2109F-11 0.2mm 0-100-0 ±0.002mm ±0.003mm
5mm 2119-51 0.2mm 0-10-0 ±0.005mm ±0.008mm
0.002mm 0.5mm 2010F-11 0.2mm 0-20 ±0.002mm
2010F-61 0.2mm 0-20 ±0.002mm
2011F-11 0.2mm 0-10-0 ±0.002mm
2011F-61 0.2mm 0-10-0 ±0.002mm
0.005mm 1.25mm 2120F-11 0.5mm 0-50 ±0.005mm
2120-71 0.5mm 0-50 ±0.005mm
2121F-11 0.5mm 0-25-0 ±0.005mm
2121-71 0.5mm 0-25-0 ±0.005mm
0.01mm 2.5mm 2230F-01 1mm 0-100 ±0.010mm
2230F-11 1mm 0-100 ±0.010mm
2231F-01 1mm 0-50-0 ±0.010mm
2231F-11 1mm 0-50-0 ±0.010mm
5mm 2044F-01 1mm 0-100 ±0.010mm ±0.010mm
2044F-61 1mm 0-100 ±0.010mm ±0.010mm
2045F-01 1mm 0-50-0 ±0.010mm ±0.010mm
2045F-61 1mm 0-50-0 ±0.010mm ±0.010mm
10mm 2046F-01 1mm 0-100 ±0.010mm ±0.013mm
2046F-11 1mm 0-100 ±0.010mm ±0.013mm
2046F-61 1mm 0-100 ±0.010mm ±0.013mm
2047F-01 1mm 0-50-0 ±0.010mm ±0.013mm
2046F-01 2047F-11 1mm 0-50-0 ±0.010mm ±0.013mm
2048F-01 1mm 0-100 ±0.010mm ±0.015mm
2048F-11 1mm 0-100 ±0.010mm ±0.015mm
2902F-01 1mm 100-0 ±0.010mm ±0.013mm
20mm 2050F-01 1mm 0-100 ±0.010mm ±0.020mm
2050F-11 1mm 0-100 ±0.010mm ±0.020mm
25mm 2056F-01 1mm 0-100 ±0.010mm ±0.025mm
0.02mm 5mm 2032F-11 2mm 0-200 ±0.020mm
2033F-11 2mm 0-100-0 ±0.020mm
The measuring force for all of the above indicators is 1.5N or less except for the following:
2050F-01, 2050F-11, 2056F-01; 2.0N or less, 2045F-61, 2046F-61; 2.5N or less.
The conversion factor between Newton force and gram force is 1N=101.94gf.
Lug back is standard: for flat back version of indicator add ‘B’ to the order number, e.g. 2046FB-11.
High Precision Type Reverse Reading Balanced Dial Continuous Dial One Revolution
Damper at Lowest Rest Point Shockproof Adjustable Hand Waterproof Double Scale Spacing
Coaxial Revolution Counter Peak Retaining Long Stem Dustproof Jeweled Low Force
R-65
R-066 (2003) full size 12/9/03 1:23 PM Page 1
DIAL INDICATORS/METRIC
D
2231F-01 2.15” .47” .59” 1.78”
2.19" (2.28")
2.05" (2.13")
2231F-11 2.15” .47” .59” 1.78”
.63"
2044F-01 2.24” .56” .59” 1.78”
2044F-61 2.24” .88” .27” 1.78”
2045F-01 2.24” .56” .59” 1.78”
2045F-61 2.24” .88” .27” 1.78” .25"
A
0
C
.375" -.001
2046F-11 2.45” .77” .59” 1.90”
2046F-61 2.45” 1.09” .27” 1.79”
B
2047F-01 2.45” .77” .59” 1.90” #4-48 Threads
6 6
6
14 6 30 30
JEWELS
1 0
SHOCK PROOF SHOCK PROOF
6
SHOCK PROOF
1 0
SHOCK PROOF
.6 .4
.8 .2 1 0
2 2 2
13 7 7
1.0 0
7 3 7 3
7 3
8 8 12 8 8 8 40 40
9 10 9 11 10 9 9 10 9 50
10 0
70 2
1
0
9
8
SHOCK PROOF
30 30 2
1
0
9
8
SHOCK PROOF
30 70
9 0.01mm 1
30
3 7 3 7
8 2
4 6 4 6
7 3
5 5 6 5 4
60 40 40 40 60 40
50 50 50
R-66
R-067 (2003) full size 12/9/03 1:24 PM Page 1
DIAL INDICATORS/METRIC
High Precision Type Reverse Reading Balanced Dial Continuous Dial One Revolution
Damper at Lowest Rest Point Shockproof Adjustable Hand Waterproof Double Scale Spacing
Coaxial Revolution Counter Peak Retaining Long Stem Dustproof Jeweled Low Force
R-67
R-068 (2003) full size 12/9/03 1:24 PM Page 1
DIAL INDICATORS/METRIC
D
2124F 60 14.7 17.5 46.8 17
2044F 64.8 19.5 17.5 46.8 16.5
2044FE-09 64.8 19.5 17.5 46.8 16.5
ø55.6
ø52
16
2044F-60 64.8 25 13 46.8 16.5
2045FE 64.8 19.5 17.5 46.8 16.5
2045F-60 65.8 25 13 46.8 16.5
5
A
2046F 64.8 19.5 17.5 46.8 16.5
2046FE 64.8 19.5 17.5 46.8 16.5 ø8-0.009
0
C
2046F-60 69.5 28.7 13 46.8 16.5
2046FE-09 64.8 19.5 17.5 46.8 16.5 M2.5x0.45
B
2046F-69 69.5 28.7 13 46.8 16.5
2046FE-10 64.8 19.5 17.5 46.8 17 8 Unit: mm
2047FE 64.8 19.5 17.5 46.8 16.5
2310FE 64.8 19.5 17.5 46.8 17
2902FE 64.8 19.5 17.5 46.8 16.5
2050F-60 87 46.2 13 55.5 16.5
2050FE* 75 29.7 17.5 40 16.5
2320FE* 75 29.7 17.5 40 17
2052FE* 88.5 43 17.5 40 16.5
2330FE* 88.5 43 17.5 40 17
2952FE* 88.5 43 17.5 40 16.5
*Denotes the indicator does not feature a cap (dimension ‘D’ is taken to the
screw top, which rises with the spindle).
0 0
0 0
90 10 455 5
90 45
10
1µm 5µm
80 20 40 10 10
40
20 80
6 JEWELS
0
30 70 JEWELED
35
70 .2
.1 0
1.0 30 3515
1 4
15
.3 .9
2 3
.4 .8
.5 .6 .7
40 60 20 30
60 40 30 25
20
50
50 25
2110F 2124F
R-68
R-069 (2003) full size 12/9/03 1:25 PM Page 1
DIAL INDICATORS/INCH
Specifications
Inch–ANSI Standard (Stem Diameter 3/8")
Total Range Dial Accuracy
Graduation Range Order No. Per Rev. Reading 2-1/3 Rev. Total Range Features
3571 .0001" .025" 3802-10 .01" 0-10 ±.0001" ±.0002"
3803-10 .01" 0-5-0 ±.0001" ±.0002"
.0005" .075" 3570 .03" 0-30 ±.0005" ±.0005"
3571-10 .03" 0-15-0 ±.0005" ±.0005"
.001" .125" 3780 .05" 0-50 ±.001" ±.001"
3781 .05" 0-25-0 ±.001" ±.001"
.25" 3410 .1" 0-100 ±.001" ±.001"
3411 .1" 0-50-0 ±.001" ±.001"
.4" 3412 .1" 0-100 ±.001" ±.001"
3413 .1" 0-50-0 ±.001" ±.001"
1" 3416 .1" 0-100 ±.001" ±.002"
3417 .1" 0-50-0 ±.001" ±.002"
2" 3424-10 .1" 0-100 ±.001" ±.003"
3" 3426-10 .1" 0-100 ±.001" ±.005"
4" 3428-10 .1" 0-100 ±.001" ±.005"
The measuring force for all of the above indicators is 1.5N or less, except for the following:
3424-10; 2.1N or less: 3426-10; 3.0N or less: 3428-10; 4.0N or less.
The conversion factor between Newton force and gram force is 1N=101.94gf.
Lug back is standard; for flat-back version add ‘B’ to the order number,
e.g. 3802B-10.
High Precision Type Reverse Reading Balanced Dial Continuous Dial One Revolution
Damper at Lowest Rest Point Shockproof Adjustable Hand Waterproof Double Scale Spacing
Coaxial Revolution Counter Peak Retaining Long Stem Dustproof Jeweled Low Force
R-69
R-070 (2003) full size 12/9/03 1:25 PM Page 1
DIAL INDICATORS/INCH
Order No. A B C D
3802-10 2.28” .32” .59” 2.14”
3803-10 2.28” .32” .59” 2.14”
3570 2.32” .36” .59” 2.14”
D
ø26"
3571 2.32” .36” .59” 2.14”
3780 2.39” .42” .48” 2.14”
ø2.97"
2.76"
.63"
3781 2.39” .42” .48” 2.14”
3410 2.56” .77” .59” 2.14”
3411 2.56” .77” .59” 2.14”
3412 2.72” .75” .59” 2.14” .25"
A
3416* 3.30” 1.33” .59” 1.83” 0
ø.375"-.001
C
3417* 3.30” 1.33” .59” 1.83”
3424-10 5.79” 2.30” 2.01” 5.04”
B
#4-48 Threads
3426-10 7.32” 3.41” 2.43” 6.57”
3428-10 9.33” 4.42” 3.43” 8.03” .33"
*Denotes the indicator does not feature a cap (dimension ‘D’ is taken
to the screw top, which rises with the spindle).
0 _ 0 + 0
9 1 45 5
.0001"
5 5
8 2 .0005"
40
.001"
10
NO. 3 8 0 2 -10 ®
0 6 JE WELS
NO.3571 ® NO. 3 7 8 0
1 0 0
7 2
SHOCK PROOF
MADE IN JAPAN
3 2
1 JEWELED
MADE IN JAPAN
35 2
1
15
10
3
3
10 3
6 4 30 20
5 15 25
R-70
R-071 (2003) full size 12/9/03 1:26 PM Page 1
DIAL INDICATORS/METRIC
Specifications
Metric–ANSI Standard (Stem Diameter 3/8" with yellow dial face)
Total Range Dial Accuracy
Graduation Range Order No. Per Rev. Reading 2-1/3 Rev. Total Range Features
0.002mm 0.5mm 3010-11 0.2mm 0-20 ±0.002mm
3011-11 0.2mm 0-10-0 ±0.002mm
0.01mm 2.5mm 3230-01 1mm 0-100 ±0.010mm
3231-01 1mm 0-50-0 ±0.010mm
30mm 3052-01 1mm 0-100 ±0.010mm ±0.025mm
3052-11 1mm 0-100 ±0.010mm ±0.025mm
50mm 3058-01 1mm 0-100 ±0.015mm ±0.035mm
3058-11 1mm 0-100 ±0.015mm ±0.035mm
_ 0
1 0 +1 19 0 1 10 0 10 90
0
10
2 2 18 2 20 20 10 90
3 3 17 3 30 30
2µm 2µm 1µm 0.01mm
4 4 16 8020 80 20
4 40 40
5 NO. 3011-11 ®
5 15 5 50
NO. 3109 -10 ®
50 NO. 3046 ®
NO. 3010-11 ® 0
1 0 6
1 0
1 9
6
JEWELS 6 0 1
MADE IN JAPAN
70
6
JEWELS 9
6
6 7030 30
JEWELS
60 60 2
SHOCK PROOF 8
14
MADE IN JAPAN
2 2 SHOCK PROOF 8 2
0 1.0 3 7 3 7
3 3 .2 .8 6 4
4 5 6
7 7 13 7 70
.4 .6
70 40
5
60
8 8 12 8 80 80 60 50 40
9 10 9 11 10 9 90 100 90 50
High Precision Type Reverse Reading Balanced Dial Continuous Dial One Revolution
Damper at Lowest Rest Point Shockproof Adjustable Hand Waterproof Double Scale Spacing
Coaxial Revolution Counter Peak Retaining Long Stem Dustproof Jeweled Low Force
R-71
R-072 (2003) full size 12/9/03 1:27 PM Page 1
DIAL INDICATORS/METRIC
D
ø.26"
3230-01 2.35” .39” .48” 2.14”
3231-01 2.35” .39” .48” 2.14”
ø2.95"
2.76"
.63"
3052-01* 4.00” 1.46” 1.05” 2.85”
3052-11* 4.00” 1.46” 1.05” 2.85”
3058-01* 5.47” 2.23” 1.76” 3.20” .25"
A
3058-11* 5.47” 2.23” 1.76” 3.20”
0
ø.375"-.001
C
*Denotes the indicator does not feature a cap (dimension ‘D’ is taken
to the screw top, which rises with the spindle).
B
#4-48 Threads
Unit: mm
Ø6.5
16
ø71
Ø78
5
A
0
Ø8 -0.009
C
B
Unit: mm
M2.5x0.45
3050F* 93 29 25 49 16.5
3052F* 104 40 25 73 17
3058F* 142 60 43 82 17
D
Ø6.5
3060F* 203 91 73 112 17
16
Unit: mm
5
*Denotes the indicator does not feature a cap (dimension ‘D’ is taken
to the screw top, which rises with the spindle).
A
0
Ø8 -0.009
C
B
M2.5x0.45 Unit: mm
R-72
R-073 (2003) full size 12/9/03 1:27 PM Page 1
DIAL INDICATORS/INCH
Specifications
4802-10 Inch–ANSI Standard (Stem Diameter 3/8")
Total Range Dial Accuracy
Graduation Range Order No. Per Rev. Reading 2-1/3 Rev. Total Range Features
.0001" .025" 4802-10 .01" 0-10 ±.0001" ±.0002"
4803-10 .01" 0-5-0 ±.0001" ±.0002"
.05" 4818-10 .02" 0-20 ±.0003" ±.0003"
.0005" .075" 4570 .03" 0-30 ±.0005" ±.0005"
4571 .03" 0-15-0 ±.0005" ±.0005"
.001" .25" 4410 .1" 0-100 ±.001" ±.001"
4411 .1" 0-50-0 ±.001" ±.001"
3" 4887 .1" 0-100 ±.001" ±.005"
The measuring force for all of the above indicators is 1.5N or less, except for the following:
4887; 2.5N or less.
The conversion factor between Newton force and gram force is 1N=101.94gf.
Lug back is standard; for flat-back version add ‘B’ to the order number, e.g. 4802B-10
High Precision Type Reverse Reading Balanced Dial Continuous Dial One Revolution
Damper at Lowest Rest Point Shockproof Adjustable Hand Waterproof Double Scale Spacing
Coaxial Revolution Counter Peak Retaining Long Stem Dustproof Jeweled Low Force
R-73
R-074 (2003) full size 12/9/03 1:30 PM Page 1
DIAL INDICATORS/INCH
.71" .75"
Dimensions
Order No. A B
2.16" (6.26")
4802-10 2.64” .34”
4803-10 2.64” .34” ø26"
4818-10 2.66” .36”
4570 2.66” .36”
ø3.56"
ø2.76"
4571 2.66” .36”
.63"
4410 2.87” .57”
4411 2.87” .57”
4887 7.24” 3.74”
.25"
.52" (2.13")
A
0
ø.375"-.001
B
#4-48 Threads
_ 0 + 0 _ 0 +
1 1 9 1
3 3
JEWELED
6 JEWELS 6 JEWELS
7 3
2 2 2
SHOCK PROOF SHOCK PROOF
3 3 3
20 10
4 4 6 4
5 5 15
R-74
R-075 (2003) full size 12/9/03 1:32 PM Page 1
DIAL INDICATORS/METRIC
4230-01
Specifications
Metric–ANSI Standard (Stem Diameter 3/8" with yellow dial face)
Total Range Dial
Graduation Range Order No. Per Rev. Reading Accuracy Features
0.01mm 2.5mm 4230-01 1mm 0-100 ±0.01mm
4231-01 1mm 0-50-0 ±0.01mm
High Precision Type Reverse Reading Balanced Dial Continuous Dial One Revolution
Damper at Lowest Rest Point Shockproof Adjustable Hand Waterproof Double Scale Spacing
Coaxial Revolution Counter Peak Retaining Long Stem Dustproof Jeweled Low Force
R-75
R-076 (2003) full size 12/9/03 1:35 PM Page 1
DIAL INDICATORS/METRIC
Dimensions Dimensions
19 21
.71" .78"
58
2.13"
ø6.5
ø.26"
ø70
ø91
ø3.56"
16
ø2.76"
.63"
5
.25"
2.70"
83
0
19
ø8 -0.009
.51"
0
ø.375"-.001
18.5
M2.5x0.45 Threads
.40"
#4-48 Threads
0 0
0
90 90 10
10 10 90
0.01mm 0.01mm
80 20 8020 8020
NO. 4046
NO.4230
NO. - 01
4230-01 0
0 1 0 1
9 MADE IN JAPAN
9
1 2 8
70
70
8 2
30 7030 30
2
3 7 3 7
3 6
5
4
6
4
5
40 60
60 40 60 40
50
50 50
4230-01 4046
R-76
R-077 (2003) full size 12/9/03 1:35 PM Page 1
SPECIAL INDICATORS
High Precision Type Reverse Reading Balanced Dial Continuous Dial One Revolution
Damper at Lowest Rest Point Shockproof Adjustable Hand Waterproof Double Scale Spacing
Coaxial Revolution Counter Peak Retaining Long Stem Dustproof Jeweled Low Force
R-77
R-078 (2003) full size 12/9/03 1:36 PM Page 1
SPECIAL INDICATORS
ø.26"
ø.31" (ø6.5)
D
(ø8.5)
D
G
E
(16)
.63"
E
.25"
A
A
(5)
0
C
ø.375"-.001
C
.375"0-0012"
0 0
(ø8.0 - 0.009) (Ø8 -0.009)
(Ø4.8)
B
(M2.5 x 0.45) #4-48 THREAD
(M2.5 X 0.95)
H Unit: Inch (mm)
Unit: Inch (mm)
One Revolution
_ _ 0 +
0 +
5 5 10 10
_ 0 + _ 0 + 10 10 20 20
5 5
1 1
10 10 15 15
2 2
30 30
15 15 .0005"
.0001"
NO. 1910-72 20 NO. 2909-62 20 .001"
NO. 2908-62
3
SHOCK PROOF
3
20 .0005"
NO. 1909-62
SHOCK PROOF
20 SHOCK PROOF 40 SHOCK PROOF 40
R-78
R-079 (2003) full size 12/9/03 1:37 PM Page 1
SPECIAL INDICATORS
Accessories
A. 900933 Hole attachment with .157" DIA. point.
B. 900934 “C” Clamp, Capacity 1.33".
C. 125341 Upright rod, Length 4.52", .472" DIA.
D. 125342 Square holder .472" x .472".
E. 900935 Universal clamp.
3.86" (98)
1.63" (41.5)
ø.250"
(ø 6.35)
.87"
(22)
1.85" (47)
0
ø.375"-0.001 3.19" (81)
0
(ø9.52 -0.009 )
0 _ 0 + 0 _ 0+
10 240 20 20 20
90 10 10
220 40 40 40
. 0 01" . 0 01" 0.02mm 0.02mm
80 20 20 20
200 60 60 60
70 30 30 30 180 80 80 80
NO.1156 NO.115 7 NO.115 8 NO.115 9
High Precision Type Reverse Reading Balanced Dial Continuous Dial One Revolution
Damper at Lowest Rest Point Shockproof Adjustable Hand Waterproof Double Scale Spacing
Coaxial Revolution Counter Peak Retaining Long Stem Dustproof Jeweled Low Force
R-79
R-080 (2003) full size 12/9/03 1:37 PM Page 1
SPECIAL INDICATORS
1.00"
(25.5)
1.57"
(40)
ø1.38" ø1.38"
.98"
(25)
.98"
(25)
(ø35) 0
(ø35) ø2.28"
0
ø.375"-.001 ø.375"-.001
(ø51)
L
L
0
(26.5)
1.04"
0
(ø8 -0.009 ) (ø8 -0.009 )
0
#4-48 Threads ø.375"-.001
L
#4-48 Threads 0
(ø8 -0.009 )
(M2.5x0.45)
(M2.5x0.45) .18"
(4.5) #4-48 Threads
(M2.5x0.45)
.18"
(4.5)
_ 0 +
10 0 10
1 1
0 _ 0 10
0
10 20 20
45 5 5 + 5
2 2
20 20 30 30
40 10 10 10
30 30
.001"
N o. 1 1 6 6
3 .0001" 3 40 40
1µm
35 0 .2 15 15 .001"
15 NO. 2991
NO. 1960
40 0.01mm 40 50
NO. 2990
.1
SHOCK PROOF
6 JEWELS
SHOCK PROOF
6 JEWELS
50
4 4
NO. 1960 SHOCK PROOF
20 20 20
MADE IN JAPAN
30
SHOCK PROOF
50 50
MADE IN JAPAN
25
High Precision Type Reverse Reading Balanced Dial Continuous Dial One Revolution
Damper at Lowest Rest Point Shockproof Adjustable Hand Waterproof Double Scale Spacing
Coaxial Revolution Counter Peak Retaining Long Stem Dustproof Jeweled Low Force
R-80
R-081 (2003) full size 12/9/03 1:38 PM Page 1
SPECIAL INDICATORS
Hicator
Series 524
The Hicator is Mitutoyo’s ultra-sensitive dial indicator. These devices are
capable of providing measurements up to 50 millionths of an inch
(.00005"). The spindle is made of highly durable stainless steel, and these
indicators feature jeweled bearings for extreme sensitivity and long life.
Specifications
HICATOR–Metric (Stem Diameter 8mm)
Total Dial
Graduation Range Order No. Reading Accuracy Features
0.0005mm ±0.03mm 524-500 30-0-30 ±0.5µm
0.001mm ±0.05mm 524-501 50-0-50 ±1µm
Standard Accessory: 540774 Spindle Lifting Cable
The measuring force for all the above indicators is 1.2N or less.
The conversion factor between Newton force and gram force is 1N=101.94gf.
The spindle stroke for the hicators above is: Inch model; .118", Metric model; 3mm.
Specifications
HICATOR–Inch (Stem Diameter 3/8")
Total Dial
Graduation Range Order No. Reading Accuracy Features
.0001" ±.004" 524-606 4-0-4 ±.0001"
.0005" ±.02" 524-607 20-0-20 ±.0003"
524-607 HICATOR–Metric (Stem Diameter 8mm)
Total Dial
Graduation Range Order No. Reading Accuracy Features
0.001mm ±0.05mm 524-601 50-0-50 ±1µm
0.002mm ±0.1mm 524-602 100-0-100 ±1.5µm
0.01mm ±0.5mm 524-603 50-0-50 ±5µm
Standard Accessory: Signal Cable 139404.
The measuring force for all the above indicators is 1.2N or less.
The conversion factor between Newton force and gram force is 1N=101.94gf.
The spindle stroke for the hicators above is: Inch model; .118", Metric model; 3mm.
High Precision Type Reverse Reading Balanced Dial Continuous Dial One Revolution
Damper at Lowest Rest Point Shockproof Adjustable Hand Waterproof Double Scale Spacing
Coaxial Revolution Counter Peak Retaining Long Stem Dustproof Jeweled Low Force
R-81
R-082 (2003) full size 12/9/03 1:39 PM Page 1
SPECIAL INDICATORS
Hicator
Series 524
.75" .35"
.75" .35"
(19) (9)
(19) (9)
1.85" (47)
1.54" (39)
ø2.39" (60.7)
ø2.39" (60.7)
ø2.20" (56)
ø2.20" (56)
2.60" (66)
2.60" (66)
.79"
(20)
0
ø.375" -.001
(20)
.79"
0
0
(ø8 -0.009 )
(15.7)
(ø8 -0.009 )
.62"
524-500 524-601 524-606
524-501 524-602 524-607 Metric Model
524-603 Unit: (mm)
Dial Indicator Faces
Hicator
0 0
1 1 5_ 5
_ + +
.0001" .0005"
2 2 10 10
524-606 524-607
3 6 JEWELES
SHOCK PROOF 3 15 6 JEWELES
SHOCK PROOF 15
4 MADE IN JAPAN
4 20 MADE IN JAPAN
20
524-606 524-607
R-82
R-083 (2003) full size 12/9/03 1:39 PM Page 1
SPECIAL INDICATORS
Hicator II
Series 524 – Dial Comparator
Features
• High accuracy and durability due to a high precision ball guide.
• Simple zero adjustment by the lockable fine adjustment screw.
• Constant measuring force over the entire range is
accomplished by the built-in compression spring.
• Shockproof movement prevents transmission of impact
to the inside components.
• Adjustable tolerance markers allow easy setting of limits.
• Optional splash guard cover and rubber bellows protect
the Hicator-II from water & contaminants.
524-522
shown with Standard Accessories
optional User’s manual
splash guard Inspection certificate
cover
Optional Accessories
2.48" Front panel
.79"
Contact point (steel ball) 02AZA720
Tolerance markers
.71"
Color : mancel N2.5
Housing
Color : silver
Contact point (ruby ball) 02AZA721
Spindle lifting knob 02AZA764
10 0 10
30
20
1µm
20
30
0
0.00005"
1
LY JEWELED
Code No.
524-52
Mitutoy
Splash guard cover 02AZA765
1
40 40 Rubber bellows 02AZA766
2
50 50
2 Mounting holder 02AZA767
Hicator-ll
Spindle lifting cable 540774
3.83"
cator-ll
Release hole Zero adjustment screw Optional contact points for Hicator-II are available by
using DiaI Indicator contact points with M2.5x0.45mm
.79"
0
3/8" -.00012 ø9.53h
.59"
.31"
(8mm)
thread.
ø.157
Adapter Brush
.56"
.48"
.33"
Contact Point
Specifications
HICATOR-II Type
Code No. 524-521 524-522 524-523 524-524
Model No. HR-1 HR-1E HR-05 HR-06E
Graduation 0.001mm .00005" 0.0005mm .00002”
Measuring range ±0.05mm ±.002” ±0.025mm ±.001”
Dial face 50-0-50 2-0-2 25-0-25 1-0-1
Accuracy 1.2µm .00006” 0.6µm .000024”
Hysteresis 0.5µm .000025” 0.25µm .00001”
Repeatability 0.5µm .000025” 0.25µm .00001”
Stem Diameter 8mm 3/8" 8mm 3/8"
Spindle guide Ball guide
Contact point Steel ball Ruby ball
Measuring force 1N ±0.2N
The measuring force for all of the above Hicators is 1N ± 0.2N.
The conversion factor between Newton force and gram force is 1N=101.94gf.
R-83
R-084 (2003) full size 12/9/03 1:40 PM Page 1
ACCESSORIES/STANDS
PROTECTIVE COVERS
Clear plastic protective covers are available that
surround and protect the indicators from oils, dust and
flying particles.
LIMIT STICKER
Stuck on the dial face or crystal of a dial indicator to Limit
indicate tolerance limits. Sticker
Three colors - red, green, and yellow.
R-84
R-085 (2003) full size 12/9/03 1:40 PM Page 1
ACCESSORIES/STANDS
Adjustable Back
Adjustable Back
Dimension
Order No. t L Thread
Series 0 21BAA005 .07" (1.7) .25" (6.35) 1/4-20UNC
Series 1 129721 .09" (2.2) .25" (6.35) 1/4-20UNC
Series 1 136025 .09" (2.2) .25" (6.35) M6X1mm
Series 2 101168 .14" (3.5) .21" (5.35) 1/4-20UNC
Series 2 136026 .14" (3.5) .25" (6.35) M6X1mm
Series 3, 4 100838 .14" (3.5) .21" (5.35) 1/4-20UNC
Series 3, 4 136027 .14" (3.5) .21" (5.35) M6X1mm
Unit: (mm)
R-85
R-086 (2003) full size 12/9/03 1:41 PM Page 1
ACCESSORIES/STANDS
R-86
R-87 (2003) full size 12/9/03 8:41 PM Page 1
ACCESSORIES/STANDS
Unit : (mm)
Unit : (mm)
4-48UNF
L Carbide Sapphire Ruby Plastic 4-48UNF
.28" — — — 902018 D d Radius L Order No.
.3" 131262 131263 131264 — Ø.2" Ø.17" .2" .2" 131273
.6" 131265 131266 131267 — Ø.27" Ø.25" .16" .4" 131274
1" 131268 131269 131270 — Ø.41" Ø.37" .4" .4" 131275
Spherical Point
Shell Type Point 4-48UNF
D L Radius Order No.
Ø 1/2" 1/8" .28" 101205
Ø 3/8" 3/32" .35" 101204
4-48UNF
Order No. M2.5 x 0.45mm
900032 101122
R-87
R-088 (2003) full size 12/9/03 1:46 PM Page 1
ACCESSORIES/STANDS
Flat Point
Knife Edge Point, Carbide Tipped 4-48UNF
D L Order No.
Ø 1/2" 3/8" 101188
4-48UNF Ø 3/8" 3/8" 101189
131282
M2.5 x 0.45mm
D L Order No.
25°
M2.5 x 0.45mm
120067
M2.5 x 0.45mm
D T Order No.
90° Conical Point, Carbide Tipped
2mm 0.4mm 120061
Unit : (mm) 2mm 0.6mm 120062
4mm 1mm 120063
Unit : (mm)
Unit : (mm)
4-48UNF 4-48UNF 4-48UNF 4-48UNF
L Order No. L Order No. L Order No. L Order No.
1/2" 101190 1/4" 101191 .08" 131272 .3" 131283
R-88
R-089 (2003) full size 12/9/03 1:46 PM Page 1
ACCESSORIES/STANDS
Point Conversion
M2.5 x 0.45mm
ORDER NO.
901954
Unit : (mm)
131271 Needle Point ø.078" .04" Long 101186 Shell Type Point 3/4"
101187 Shell Type Point 1"
101188 Flat Point ø1/2"
101189 Flat Point ø3/8"
101190 60° Conical Point
101191 90° Conical Point
101204 Spherical Point ø3/8"
21AAA030 Needle Point .6"
R-89
R-090 (2003) full size 12/9/03 1:47 PM Page 1
DIAL INDICATORS
Repair Tool Kit
MITUTOYO offers a tool set designed to let you perform 8
simple repairs to your Mitutoyo dial indicator, and a device
that lets you reset the indicator crystals. 10
• To free a jammed bezel; Apply Molykote with a brush (8)
around the entire groove of the bezel.
9 7
• To oil a bearing: Use brush (9) to apply lubricating oil to 4
the pinion shaft.
• To remove the long pointer: Use hand remover (15) to lift 6 5
out without damaging the bearing.
• To remove the short pointer: Use nippers (13).
• To adjust the bearing position: Use the bearing adjuster 1 2 3
(18) to force the bearing into position.
• To remove the pin or drive it into position: Use the pin 16 17 18
remover (16) and hammer (10) on the V-groove of the 15
spindle rest (11). 19 20
• To drive the long or short pointer into position: Use the
pinion rest (19) and pin rest (12) to hold the pin and
pinion, then drive with hammer (10) and punch (17) into 14
the center position.
Crystal Setter 7
(Order No. 7000)
Used for fitting a crystal on dial indicators, dial test indica-
tors and dial calipers.
Features 6
• Use setting pads (2) and (3) for pocket-type dial test
indicator.
• Use setting pads (3) and (4) for dial test indicator,
universal dial test indicator, Series 1 dial indicators, and
dial calipers.
• Use setting pads (7) and (8) for Series 2 dial indicators
and dial height gages with counter. 1 2 3 4 5 8
R-90
R-091 (2003) full size 12/9/03 1:47 PM Page 1
ACCESSORIES/STANDS
1.57"
Hardened Steel Anvil
Order No. Capacity Adjustment Remarks Flatness 1µm or less
7003 4.0" .04" with Serrated Anvil (No. 101462) and Swivel
8.07"
Clamp Assembly (No. 990264),
.55"
2.28"
Stem Clamp: .375" (9.5mm) 7003
2.32"
7004
1.77"
7004 4.0" .04" with Flat Anvil (No. 101461) and Swivel
Clamp Assembly (No. 990264),
Stem Clamp: .375" (9.5mm) 3.93" (W) x 6.30"(D)
7102 4.0" .04" with Flat Anvil (No. 101461) and 1.18"(DIA)
Swivel Clamp Assembly (No. 58ZAA014)
STEM CLAMP
Stem Clamp: .591"(15mm) 0.004
ø 15" .0
7102
1.97"
101463 Domed Anvil (20mm radius) 58ZAA014 Swivel Clamp Assembly (7102)
302380 Screw for Anvil 168
4.33" (W) x 6.61" (D)
Specifications
Dial Gage Stands 3.15"
Max. Height Fine 1.18" (DIA)
Stem clamp: .375"
Order No. Capacity Adjustment Remarks
7008 3.54" .039" Serrated Anvil type. Stem Clamp: .375"
Hardened Steel Anvil
1.97"
3.54"
206983 Stem Collar for 8mm stem gage. 7008
2.48"
1.77"
R-91
R-092 (2003) full size 12/9/03 1:48 PM Page 1
ACCESSORIES/STANDS
Comparator Stands
Series 215
215-407
1.18"
(ø30mm) ø1.97
(50mm)
Fine Adj.
Control
215-514
215-407 4.53"
(115mm) 215-515
3.74"
(95mm)
15.75"(400mm)
Squareness
18.28"(464mm)
12.00"(305mm)
0.2/100
9.84"(250mm)
Parallelism
≤ 3 µm
3.94"(100mm)
Squareness 0.2/100
(300mm)
11.81"
(25mm)
(25mm)
Parallelism 5.91"
(50mm)
.98"
1.97"
(110mm)
(90mm)
(80mm)
6.69"max.
3.15"
(65mm)
(170mm)
(55mm)
3.5"
2.56"
2.17"
MITUTOYO Comparator Stands are basic building-blocks The Comparator Stands consist of a very stable, cast-
for the assembly of special-purpose, precision-measuring iron base and an upright column with a mounting bracket
equipment. By mounting precision-measuring instruments that features fine adjustment. Standard Stands are fur-
onto the stands, it is possible to satisfy all manners of nished with tapped holes for mounting optional anvils,
measuring assignments, including comparative measure- although the flat, accurately-ground stand surfaces are
ment. true measuring planes. The Comparator Stands are also
available without the tapped holes.
Specifications
Comparator Stands
Max. Work Anvil Stem
Order No. Height Type Size Mass Remarks
215-407 6.69" Serrated .375" 18.2 lbs Post Type: Straight
Fine Adjustment Length: .04"
215-514 11.81" Serrated .375" 37.5 lbs Post Type: Spiral
Fine Adjustment Length: 10.2"
215-515 11.81" Serrated .787" or 37.5 lbs Post Type: Spiral
.375" Fine Adjustment Length: 10.2" with Bushing
R-92
R-093 (2003) full size 12/9/03 1:49 PM Page 1
ACCESSORIES/STANDS
Comparator Stands
Series 215
215-831
Serrated Anvil
390074
Features
• Has rigid construction and fine adjustments, which • The flatness of the anvil surface is less than
makes the Comparator Stand suitable as a gaging .000008"/0.2µm, which is suitable for precision mea-
stand for detector heads of Mu-Checkers. surement with a .00005"/0.001mm-resolution Digimatic
• Can mount dial indicators and Hicators. indicator or Linear Gage.
• Interchangeable anvils. • The anvil has grooves in a grid pattern to prevent the
workpiece from sticking to it.
• Can be used for measuring roundness and straight-
ness. • One-piece bracket for high rigidity and easy parallel
adjustment.
• These Comparator Stands use a rigid cast-iron base
and a hardened steel anvil.
Specifications
Comparator Stands
Order No. Description
215-831 with Serrated Anvil (No. 390074)
Accessories and Part
Order No. Description
390070 Dovetail Attachment
390074 Furnished Standard Serrated Anvil
990014 Bracket for 1.1" (Dia.) Stem Indicators
990015 4" wide serrated anvil
990018 .375" (Dia.) Steel Ball Anvil
R-93
R-094 (2003) full size 12/9/03 1:49 PM Page 1
ACCESSORIES/STANDS
Comparator Stands
Series 215
Comparator Stands (Series 215)
Order No. Description
215-630 Fine Adjustment Length: .04"
215-640 Fine Adjustment Length: .079"
1.18" (DIA)
2.75"
2.36"
(11.81")
(4.72")
7.87"
4.49"
(6.69")
5.90"
215-630 (10.82")
(2.75")
2.48"
215-640
5.59" 7.95"
Shown with IDF Indicator (543-552A). Serrated anvil (7.87") (12.40")
(58ZAA017) and fixed bracket (58ZAA011)
215-630 (215-640)
Accessories
Order No. Description For Stand No. 990033
58AAA071 Base for 215-630 (no tapped holes) 215-630
58AAA073 Base for 215-640 (no tapped holes) 215-640
58ZAA010 Fixed Bracket (throat depth 2.36") 215-630
58ZAA011 Fixed Bracket (throat depth 4.72") 215-640 990031
990029 Serrated Anvil (W)1.5" x (D)4" x (H)1.5" 215-630
58ZAA017 Serrated Anvil (W)5.5" x (D)5.12" x (H).67" 215-640
990031 Domed Anvil (spherical radius .59") 215-630 and 215-640
990033 Dial Holder for .375" (DIA) Stems 215-630 and 215-640
58ZAA011
APPLICATION EXAMPLES
Dial Indicator clamped directly to Comparator Stand. Digimatic Indicator mounted on Comparator Stand by
NOTE: It is necessary to rotate the lug back of the indi- Dial Holder (990033). Dial Holder accommodates instru-
cator to its horizontal position. ments with .375" DIA. Stems, such as: Dial & Digimatic
Indicators without lug-on-center back, Gage Heads,
Cartridge Heads, Electronic Comparators.
R-94
R-095 (2003) full size 12/9/03 1:50 PM Page 1
ACCESSORIES/STANDS
517-895 517-898
(Stand Only) (Stand Only)
Specifications
Precision Granite Stands
Column Column Throat Table Table
Order No. Base Diameter Height Clearance Flatness Thickness Weight
517-890 6 x 8" 1.181" 6" 4.375" .0001" 2" 18 lbs
517-891 6 x 8" 1.181" 8" 4.375" .0001" 2" 19 lbs
517-892 6 x 8" 1.181" 12" 4.375" .0001" 2" 20 lbs
517-893 6 x 8" 1.181" 18" 4.375" .0001" 2" 21 lbs
517-895 8 x 12" 1.181" 6" 5.8" .0001" 2" 29 lbs
517-896 8 x 12" 1.181" 8" 5.8" .0001" 2" 30 lbs
517-897 8 x 12" 1.181" 12" 5.8" .0001" 2" 31 lbs
517-898 8 x 12" 1.181" 18" 5.8" .0001" 2" 32 lbs
517-899 8 x 12" 1.181" 24" 5.8" .0001" 2" 35 lbs
R-95
R-096 (2003) full size 12/9/03 1:51 PM Page 1
ACCESSORIES/STANDS
Mini-Magnetic Stands
2
16 3
13 13
12
7021
15
7022
7020
1
Features
No. 7022 & 7023 No. 7020 & 7021
For MITUTOYO and other test indicators. .234" Dia. For all AGD dial indicators with Standard lug on cen-
rod dimension is specially selected to allow two MITU- ter back) and MITUTOYO and other test indicators.
TOYO test indicator clamps No. 900291 and No. One end of the rod is designed to hold the Dial
900322. Supplied with 5/16" DIA., 11/2" long extra rod Indicator’s back (lug on center), and the opposite end
for other clamps, and .217" DIA., 43/8" long extensions with .234" OD. is for No. 900291 and No. 900322 test
rod No. 050066. indicator clamps. Additional rod with 5/16" and 7/32"
Dia. is also supplied.
R-96
R-097 (2003) full size 12/9/03 1:52 PM Page 1
ACCESSORIES/STANDS
Mini-Magnetic Stands
14 8
11
5 7024
7025 13
6
Features
No. 7024 & 7025 Both models come with a convenient lever to detach per-
Most complete heavy-duty for all Dial Indicators and Test manent magnet from the surface. Vee channel on the
Indicators available in the market. The installed rod has magnet allows use on round as well as flat surfaces.
.234" OD, for MITUTOYO Test Indicator’s clamp, on one No. 7020, 7021, 7024 and 7025
end, while the other end has a clamp for dial indicators. Stands take both Dial Indicators and MITUTOYO Test
An additional rod is provided for greater versatility. Indicators, plus, most other test indicators with additional
One end has 7/32" OD. (.218"), the other with 5/16" OD. rod supplied.
(.312"). The extra rod is for other clamps usually available
in the machine stop.
Specifications
Mini-Magnetic Stands
Order No. Note Rod Diameter
7022* For Test Indicators .234", 7/32", 5/16"
7023* For Test Indicators
w/Fine Adjustment .234", 7/32", 5/16"
7020* For Dial & Test Indicators .234", 7/32", 5/16" and Clamp
7021* For Dial & Test Indicators
w/Fine Adjustment .234", 7/32", 5/16" and Clamp
7024** For Dial & Test Indicators .234", 7/32", 5/16" and Clamp
7025** For Dial & Test Indicators
w/Fine Adjustment .234", 7/32", 5/16" and Clamp
*PULL: 30-35 lbs. **PULL: 60-65 lbs.
R-97
R-098 (2003) full size 12/9/03 1:53 PM Page 1
ACCESSORIES/STANDS
Mini-Magnetic Stands
Series 984
Very small magnetic stands permit use of Dial Indicators
and Test Indicators in confined areas. The stands feature
fine adjustment.
Stands No.’s 984-107 and 108, with rectangular bases,
will accept stems of 3/8" Dia. and are furnished with a
sleeve for locking on stems of 8mm Dia. These stands
also have a fixture for mounting dial indicators with lug-
on-center backs. On Stand No. 984-107 the vertical rod
is coupled to the base through a ball-and-socket joint.
Specifications
Mini-Magnetic Stands
984-108 Order No. Description Magnetic Pull
(Stand only) 984-107 Overall Height: 5.3" (Approx) 55 lbf
984-108 Overall Height: 5.5" (Approx) 55 lbf
984-107
(Stand only)
Magnetic Stands
No. 7010SN and No. 7011BN
Mitutoyo Magnetic Stands, shown on these pages,
accept all AGD-type Dial Indicators. Test Indicators and
Probes having 3/8" DIA. shank and/or Lug Back with 1/4"
DIA. mounting hole.
The ON-OFF Switch offers instant mounting and dis-
mounting without any adverse effect to
7011BN the indicators or work surface.
(Stand only) Specifications
Magnetic Stands
Order No. Description Magnetic Pull
7010S with 6" Rod and Universal Clamp 132 lbf
with 6" Adjustable Rod and
7011BN 132 lbf
Universal Clamp
R-98
R-099 (2003) full size 12/9/03 1:53 PM Page 1
ACCESSORIES/STANDS
1.18" 3.95"
.25" .375"
519-109E
16.9" 2.56"
2.28"
2.32"
6.30"
Features
• Designed for comparison measurements of height
using a dial indicator or dial test indicator.
• Highly rigid construction without anvil ensures high
repeatability.
• Rotation range of indicator holder: ±120°
390070
Dovetail attachment used with Test Indicators
Specifications
Transfer Stand
Order No. Description
519-109E Transfer Stand with Serrated Anvil (No. 101462)
Mass: 11.9 lbs.
Accessories
Order No. Description
101461 Flat Anvil
101462 Serrated Anvil
101463 Domed Anvil
302380 Anvil Screws (3 pcs)
390070 Dovetail Attachment
990264 Fine Feed Bracket Assembly.
R-99
R-100 (2003) full size 12/9/03 1:54 PM Page 1
ACCESSORIES/STANDS
One
Twist
Clamp
180°
360°
One
.375"
Twist
Clamp
"
360°
74
4.
320°
280°
360° 360°
4.
84
"
7019
3.54"
1.89"
7019 7012
(Stand Only) (Stand Only)
Universal Flexi-Stand
Magnetic Stand 7012 (Stand only)
7019 (Stand only) Features
• Accepts all AGD .375" and 8mm stems. Must order
Features Collar 206983 for 8mm stem.
• Accepts all AGD .375" and 8mm stems. • Accepts Dial and Test Indicators.
• Accepts Dial and Test Indicators. • 360° pivot, Multi-jointed arms.
• Overall Length: Approx. 15". • One clamping knob locks all flexible joints.
• Permanent magnet with on-off switch. • On-Off Switch for instant mounting and dismounting.
Specifications
Universal Magnetic Stand and Flexi-Stand
Order No. Description Magnetic Pull
Overall Height: 15" (Approx)
7019 132 lbf
with COLLAR (No. 206983)
for 8mm stem indicator
7012 Overall Height: 15" (Approx) 132 lbf
R-100
R-101 (2003) full size 12/9/03 1:55 PM Page 1
ACCESSORIES/STANDS
1.57" 1.57"
4.84"
DIA.
1.38"
7056 7056
Back View Front View 2.36 (W) x 4.33 (1)
Features Specifications
• Compact and inexpensive gaging unit that consists of Dial Upright Gage
a dial indicator and a stand. Measuring
• Suitable for inspecting small parts on the shop floor. Order No. Range Indicator Graduation Mass
7056 0–1" 2416F .001" 2.6 lbs
• Workstage diameter: 1.57"
AB
Y
with Absolute Encoder Technology
OG
EC
H N OL
T
Complete with an adjustable workstage made of
highly durable Zirconia Ceramics, a material which
needs far less care than that of traditional steel
tables. This advanced upright gage also utilizes the
new Mitutoyo IDC Indicator offering multiple functions
including ON/OFF, Preset, ZERO/ABS, Inch/Metric.
Provides SPC output for data recording and statisti-
cal functions.
.7 1.34
Features 547-033
4.53
3.74"
2.36(W)
Specifications
Digimatic Upright Gage
Measuring LCD Workstage
Order No. Range Indicator Resolution Accuracy Mass Diameter Remarks
547-033 0–.5" 543-252B .00005" ±.00015" 3.7 lbs 1.97" with SPC output
0–12.7mm 0.001mm (ceramic)
547-034 0–.5" 543-272B .0005" ±.001" 3.7 lbs 1.57" with SPC output
0–12.7mm 0.01mm (Steel)
Replacement battery: 541980 (1 pc.), 541980-10 (10 pcs.)
For SPC output order connecting cable 905338 (1m) or 905409 (2m).
R-101
R-102 (2003) full size 12/9/03 1:56 PM Page 1
MULTI-STAND
Multi-StandTM
Multiple Indicator Stands
Common Assemblies
Item Order No. Description
050588 2" Holder
Holder & Clamp Assembly 050591 050589 3" Holder
050570 Clamp
050589 3" Holder
Holder & Clamp Assembly 050592 050590 51/2" Holder
050570 Clamp
050574 Floating head
Floating Head & Clamp 050593
050570 Clamp
050571 Holding Clamps, 2pcs.
Bench Center Assembly 050595
050572 Loaded Center
050573 Dead Center
R-102
R-103 (2003) full size 12/9/03 1:57 PM Page 1
MULTI-STAND
120°
2 1/4" 050578 050581
050579 050582 3/8" 3/4"
2 3/4"
.1" .31" .25"
.2"
1/2"
1-1/16"
1 1/2"
DIAL INDICATOR CLAMP HOLDER 1 3/4"
1 1/2"
POINT ATTACHMENT 050570
CENTER HOLDING
050568
050571 1/2" 1"
050569
Individual Accessories
Item Order No. Description
Dial Indicator Point Attachment 050568 Carbide blade (t = 0.030")
LOADED CENTER
Dial Indicator Point Attachment 050569 Carbide blade (t = 0.080") 050572
Clamp Holder 050570 Complete with lock screw
Center Holding Clamp 050571 Frequently used w/Bench Centers
Loaded Center 050572 Retractable
Dead Center 050573 Stationary
Floating Head 050574 Holder can move with assembly
Main Beam 050577 12" long, self-standing 60°
Main Beam 050578 18" long, self-standing
Main Beam 050579 24" long, self-standing
3/4"
Main Beam 050580 30" long, self-standing
Main Beam 050581 36" long, self-standing DEAD CENTER
Main Beam 050582 42" long, self-standing 050573
V-Block 050583 Accepts 2" DIA.
V-Block 050584 Accepts 2" DIA., carbide V-slot
V-Block 050586 Accepts 3" DIA., carbide V-slot
Indicator Holder 050587 3/4" long
R-103
R-104 (2003) full size 12/9/03 1:57 PM Page 1
Features
• Universal and modular gaging system for
shaft-type parts.
• Set-up or reconfigure in less than 10 min.
• Can measure multiples of all the following
part attributes:
Length
Diameter
Ovality
Run-Out
Perpendicularity
Parallelism
Taper
Concentricity
• Accepts all 8mm and .375" diameter stem
indicators (Dial or Digimatic) and
Electronic gages (Mu-Checkers and Linear
Gages).
Measurement of Bearing Diameters using Absolute Measurement of Run-Out and Diameter of Valve Seat
IDC Digimatic Indicators 543-252B. with Absolute Digimatic Indicators 543-252B.
R-104
R-105 (2003) full size 12/9/03 1:58 PM Page 1
ACCESSORIES/STANDS
Set No.
950-705
Set No.
950-723
Set No.
950-728
Set No.
950-707
Specifications
Indicator/Stand Sets
Indicator IDS(543-683B) IDC(543-252B) 2804F-10 2915F-10 2416F
Stand Digimatic Indicator Digimatic Indicator Dial Indicator Dial Indicator Dial Indicator
7010SN
Magnetic Stand Set No. 950-720 Set No. 950-721 Set No. 7045 Set No. 950-700 Set No. 7046
7011BN
Magnetic Stand Set No. 950-722 Set No. 950-723 Set No. 950-702 Set No. 950-703 Set No. 950-701
7012
Magnetic Flexi-Stand Set No. 950-724 Set No. 950-725 Set No. 950-705 Set No. 950-706 Set No. 950-704
7019
Universal Stand Set No. 950-726 Set No. 950-727 Set No. 950-708 Set No. 950-709 Set No. 950-707
7003
Serrated Anvil Stand Set No. 950-728 Set No. 950-729 Set No. 950-711 Set No. 950-712 Set No. 950-710
7004
Flat Anvil Stand Set No. 950-730 Set No. 950-731 Set No. 950-714 Set No. 950-715 Set No. 950-713
R-105
R-106 (2003) full size 12/9/03 1:59 PM Page 1
THICKNESS GAGES
Quick Mini
Series 7
700-118
700-122
700-122
Specifications
Quick Mini
Inch/Metric
Order No. 700-118 700-122
Measuring Range .5"/12mm 1"/25mm
Resolution .0005"/0.01mm
Instrumental Error ±.001"/±0.02mm
Repeatability .0005"/0.01mm
Battery SR44 #541980
Battery Life: 2 years under normal use
Max. Response Speed 1,600 mm/s
Alarm Battery voltage low, overspeed
Note: SPC output is not provided on Quick Mini
R-106
R-107 (2003) full size 12/9/03 2:00 PM Page 1
THICKNESS GAGES
Features
IDS Types (Digital Reading) IDC Types (Digital Reading) Dial Indicator Types (Analog Reading)
• ON/OFF • ON/OFF • ANSI Group 2 Dial Indicator
• Inch/mm Conversion • Inch/mm Conversion
• Origin • Zero/ABS
• ±Direction Changeover • ±Direction Changeover
• SPC Output • SPC Output
• Battery Life: 20,000 hrs • Battery Life: 5,000 hrs
• Power Supply: Silver Oxide Cell • Power Supply: Silver Oxide Cell
(SR-44 1pc.) (SR-44) 1pc.)
• Indicator Used: 543-683B • Preset
or 543-693B • Provides GO/±NG Judgement
• Face Rotates 330°
• Indicator Used: 543-272B
or 543-252B
R-107
R-108 (2003) full size 12/9/03 2:01 PM Page 1
THICKNESS GAGES
Inch/Metric
Order No. Resolution Range Type Accuracy Measuring Force Indicator
547-500* .0005"/0.01mm 0–.47"/0–12mm ø.4" Flat ±.001" less than 1.5N Digimatic IDS
547-520* .0005"/0.01mm 0–.47"/0–12mm ø.4" Flat ±.001" less than 1.5N Digimatic IDS
547-526 .0001"/0.001mm 0–.47"/0–12mm ø.4" Flat ±.0002" less than 1.5N Digimatic IDS
547-300* .0005"/0.01mm 0–.4"/0–10mm ø.4" Flat ±.001" less than 1.5N Digimatic IDC
547-320* .0005"/0.01mm 0–.4"/0–10mm ø.4" Flat ±.001" less than 1.5N Digimatic IDC
547-400*1 .00005"/0.001mm 0–.47"/0–12mm ø.25" Flat ±.0015" less than 3.5N Digimatic IDC
7300 .001" 0–.4" ø.4" Flat ±.001" less than 1.5N Dial Indicator
7304 .001" 0–1.0" ø.4" Flat ±.002" less than 1.5N Dial Indicator
7322 .001" 0–1.0" ø.4" Flat ±.002" less than 1.5N Dial Indicator
7326 .0001" 0–.05" ø.4" Flat ±.0002" less than 1.5N Dial Indicator
7390FR 1/64" 0–1.0" ø.4" Flat ±.0052" less than 1.5N Dial Indicator
SPC Connecting Cables (for Digimatic models): 905338 (1m), 905409 (2m).
SPC Connecting Cables with data send button (for Digimatic models): 959149 (1m), 959150 (2m).
Metric
Order No. Resolution Range Type Accuracy Measuring Force Indicator
7301* 0.01mm 0–10mm ø.4" Flat ±0.015mm less than 1.4N Dial Indicator
7321* 0.01mm 0–10mm ø.4" Flat ±0.015mm less than 1.4N Dial Indicator
7305* 0.01mm 0–20mm ø.4" Flat ±0.025mm less than 2.0N Dial Indicator
7323* 0.01mm 0–20mm ø.4" Flat ±0.025mm less than 2.0N Dial Indicator
* Contacts are CERA (Ceramic)
*1 Contacts are Carbide
R-108
R-109 (2003) full size 12/17/03 9:17 AM Page 1
THICKNESS GAGES
547-361
7360
dimensions: in (mm)
Inch/Metric
Order No. Resolution Range Accuracy Measuring Force Indicator
547-561 .0005"/0.01mm 0–.47"/0–10mm ±.001" less than 1.5N Digimatic IDS
547-361 .0005"/0.01mm 0–.47"/0–12mm ±.001" less than 1.5N Digimatic IDC
7361 .001" 0–.4" ±.001" less than 1.5N Dial Indicator
SPC Connecting Cables (for Digimatic models): 905338 (1m), 905409 (2m).
SPC Connecting Cables with data send button (for Digimatic models): 959149 (1m), 959150 (2m).
Metric
Order No. Resolution Range Accuracy Measuring Force Indicator
547-360 .0.01mm 0–10mm ±0.020mm less than 1.5N Digimatic IDC
7360 .0.01mm 0–10mm ±0.015mm less than 1.4N Dial Indicator
R-109
R-110 (2003) full size 12/17/03 9:19 AM Page 1
THICKNESS GAGES
Recommended Combinations
Universal Type B C E B
(Interchangeable Anvils)
(23.8)
(23.8)
(23.1)
(25.4)
1.00"
.94"
.94"
.91"
A A A D
B C C E
(25.4)
(25.4)
1.00"
1.00"
(24.8)
(25.4)
1.00"
.98"
F D F D
(Points Included)
Inch/Metric
Order No. Resolution Range Accuracy Measuring Force Indicator
547-528 .0005"/0.01mm 0–.47"/0–12mm ±.001" less than 1.5N Digimatic IDS
7328 .001" 0–.4" ±.001" less than 1.5N Dial Indicator
SPC Connecting Cables (for Digimatic models): 905338 (1m), 905409 (2m).
SPC Connecting Cables with data send button (for Digimatic models): 959149 (1m), 959150 (2m).
R-110
R-111 (2003) full size 12/9/03 2:03 PM Page 1
CALIPER GAGES
209-633
Features
• Inch/mm conversion
• Sound signal when measurement result is determined
• AUTO-Power off
• 0-pre-selection
• SPC output
• Display: 7-segment-LCD, digit height .28"(7mm)
• Measuring force: 0.9–1.5N
• Battery: LITHIUM 3V (CR-123A, DL-123A) 2-point measuring contact
Part No. 64PPP477 Carbide ball diameter:
see table below
R-111
R-112 (2003) full size 12/9/03 2:03 PM Page 1
CALIPER GAGES
Features
• mm/inch conversion
• Sound signal when measurement result is determined
• Auto-Power off
• 0-pre-selection
209-837
* SPC output
* Display: 7-segment-LCD, digit height .28" (mm)
• Measuring force: 0.9 – 1.5N
• Battery: LITHIUM 3V (CR-123A, DL-123A)
Part No. 64PPP477
Specifications
Digi-Test Digimatic Caliper Gages
Inch/Metric (Not available in Canada.)
Order No. Measuring Resolution Accuracy Max. Measuring Max. Groove Min. Groove Measuring Weight
Range Depth L Depth A Width B Contacts Ib. (g)
209-868 .0078"–.492" .0002" ±.0008" 1.02" –– –– C .75
0.2–12.5mm 0.005mm ±0.015mm 26mm (340)
209-837 .012"–.984" .0005" ±.001" 3.31" .87" .06" A .79
0.3–25mm 0.01mm ±0.02mm 84mm 22mm 1.5mm (360)
209-838 .012"–.984" .0005" ±.001" 3.31" .87" .06" B .79
0.3–25mm 0.01mm ±0.02mm 84mm 22mm 1.5mm (360)
209-839* .012–.984" .0005" ±.001" 3.37" –– –– D .79
0.3–25mm 0.01mm 0.03mm 85.5mm (360)
209-640 .020"–1.969" .001" ±.002 6.69" 1.26" .08" A .97
0.5–50mm 0.02mm ±0.04mm 170mm 32mm 2.1mm (440)
209-641 .020–1.968" .001" ±.002" 6.69" 1.26" .08" B .97
0.5–50mm 0.02mm ±0.04mm 170mm 32mm 2.1mm (440)
209-642* .020–1.968" .001" ±.002" 6.69" –– –– D .97
0.5–50mm 0.02mm ±0.06mm 170mm (440)
209-643 .020–1.968" .001" ±.002" 6.69" –– –– C .97
0.5–50mm 0.02mm ±0.04mm 170mm (440)
*Mode function 2,3 does not work. For SPC output order connecting cable 011055 (2m).
R-112
R-113 (2003) full size 12/9/03 2:04 PM Page 1
CALIPER GAGES
209-794
209-783
Specifications
Dial Caliper Gages External Type
Inch
Order No. Measuring Graduation Accuracy Max. Measuring Max. Groove Min. Groove Measuring Weight
Range Depth Depth Width Contact Ib. (g)
209-791 0–.2" .0002" ±.0008" 1.07" .31" .09" K/K .26 (120)
209-792 0–.2" .0002" ±.001" 1.07" .33" .04" T .26 (120)
209-793 0–.4" .0005" ±.0008" 2.38" .32" .09" K/K .31 (140)
209-794 0–.4" .0005" ±.0008" 2.38" .35" .09" RK/K .31 (140)
209-795 0–.4" .0005" ±.0008" 2.38" .32" .05" S .31 (140)
209-796 0–.4" .0005" ±.001" 2.38" .35" .05" RS .31 (140)
209-784 0–1.0" .0005" ±.0015" 3.2" .87" .14" K/K .44 (200)
209-785 0–1.0" .0005" ±.0015" 3.2" .87" .14" RK/K .44 (200)
209-786 0–1.0" .0005" ±.0015" 3.2" .87" .14" RS .44 (200)
209-787 0–1.0" .0005" ±.0015" 3.2" .87" .14" S .44 (200)
209-782 0–2.0" .001" ±.002" 6.8" 1.26" .18" K/K .64 (290)
209-783 0–2.0" .001" ±.002" 6.8" 1.26" .18" RK/K .64 (290)
209-788 2.0–4.0" .001" ±.003" 6.8" 1.26" .18" K/K .68 (310)
209-789 0–.5" .005" ±.005" 1.38" –– –– PK .09 (40)
209-790 0–.5" .005" ±.005" 1.32" –– –– PR .09 (40)
Metric
Order No. Measuring Graduation Accuracy Max. Measuring Max. Groove Min. Groove Measuring Weight
Range Depth Depth Width Contact Ib. (g)
209-658 0–5mm 0.005mm ±0.015mm 26mm –– –– T .26 (120)
209-660 0-10mm 0.01mm ±0.02mm 59mm 5.0mm 3.0mm S .31 (140)
209-659 0–10mm 0.01mm ±0.02mm 59mm 5.0mm 3.0mm K/K .31 (140)
209-662 0–10mm 0.01mm ±0.02mm 59mm 4.8mm 2.0mm R/S .31 (140)
209-661 0–10mm 0.01mm ±0.02mm 59mm 4.8mm 2.0mm RK/K .31 (140)
209-840 0–20mm 0.01mm ±0.025mm 56mm 7mm 3.0mm S .46 (210)
209-605 0–20mm 0.01mm ±0.03mm 85.5mm 20mm 3.5mm S .44 (200)
209-601 0–20mm 0.01mm ±0.03mm 85.5mm 20mm 3.5mm K/K .44 (200)
209-606 0–20mm 0.01mm ±0.03mm 82.5mm 20mm 3.5mm RS .44 (200)
209-607 0–20mm 0.01mm ±0.03mm 82.5mm 20mm 3.5mm RK/K .44 (200)
209-843 0–10mm 0.1mm ±0.1mm 35mm –– –– PK .09 (40)
209-603 0–10mm 0.1mm ±0.1mm 33.5mm –– __ PR .09 (40)
209-602 0–50mm 0.05mm ±0.05mm 173mm 30mm 4.5mm K/K .64 (290)
209-604 0–50mm 0.05mm ±0.05mm 173mm 30mm 4.5mm R .68 (310)
R-113
R-114 (2003) full size 12/9/03 2:04 PM Page 1
CALIPER GAGES
S K/K
RS RK/K
R T
PK PR
R-114
R-115 (2003) full size 12/9/03 2:05 PM Page 1
CALIPER GAGES
209-730 209-735
Features
• Versatile I.D. measuring gage for hole diameters, inter-
nal grooves, and other hard-to-reach inside dimen- yyy
,,, yyyy
,,,,
,,,
yyy ,,,,
yyyy
sions. ,,,
yyy
,,,
yyy ,,,,
yyyy
,,,,
yyyy
209-735
3.1"
110 - 0.200
100 - 0.200
90 - 0.200
80 - 0.200
70 - 0.200
60 - 0.200
2.4"
2.9"
3.4"
3.9"
4.4"
209-715
209-894
209-715
209-894
R-115
R-116 (2003) full size 12/9/03 2:05 PM Page 1
CALIPER GAGES
A B C
Carbide ball dia. .04"(1mm) Carbide ball dia. .024"(0.6mm) Radius .004"(0.6mm)
Specifications
Dial Caliper Gages Internal Type
(Not available in Canada.)
Inch
Order No. Measuring Graduation Accuracy Max. Measuring Max. Groove Min. Groove Measuring Weight
Range Depth L Depth A Width B Contacts Ib. (g)
209-730 .10–.30" .0002" ±.0008" 1.07" .036" .016" C .26 (120)
209-731 .20–.40" .0002" ±.0008" 1.07" .087" .047" B .26 (120)
209-732 .20–.60" .0005" ±.001" 2.39" .094" .030" B .31 (140)
209-733 .40–.80" .0005" ±.001" 2.39" .210" .050" A .31 (140)
209-712 .40–1.4" .0005" ±.0015" 3.10" .200" .043" A .44 (200)
209-734 .80–1.2" .0005" ±.001" 2.38" .210" .050" A .31 (140)
209-713 1.0–2.0" .0005" ±.0015" 3.10" .200" .047" A .44 (200)
209-735 1.2–1.6" .0005" ±.001" 2.38" .210" .050" A .31 (140)
209-736 1.6–2.0 .0005" ±.001" 2.38" .210" .050" A .31 (140)
209-760 1.6–2.6" .0005" ±.0015" 3.10" .350" .047" A .44 (200)
209-761 2.2–3.2" .0005" ±.0015" 3.10" .350" .047" A .44 (200)
209-762 2.8–3.8" .0005" ±.0015" 3.10" .350" .047" A .44 (200)
209-763 3.2–4.2" .0005" ±.0015" 3.10" .350" .047" A .44 (200)
209-715* 2.4–5.4" .0005" ±.0015" 3.10" –– –– A .44 (200)
209-716* 4.7–7.7" .0005" ±.0015" 3.10" –– –– A .44 (200)
*Interchangeable contact points (additional anvil 4 pcs.) with ball point .04" dia.
Metric
Order No. Measuring Graduation Accuracy Max. Measuring Max. Groove Min. Groove Measuring Weight
Range Depth L Depth A Width B Contacts Ib. (g)
209-650 2.5–7.5mm 0.01mm ±0.015mm 10mm 0.7mm 0.6mm C .26 (120)
209-651 5–10mm 0.01mm ±0.015mm 22mm 2.2mm 1.4mm B .26 (120)
209-652 5–15mm 0.01mm ±0.02mm 30mm 1.7mm 1.1mm C .31 (140)
209-653 10–20mm 0.01mm ±0.02mm 50mm 4.0mm 2.0mm D .31 (140)
209-608 10–30mm 0.01mm ±0.03mm 80mm 4.5mm 1.2mm A .44 (200)
209-654 20–30mm 0.01mm ±0.02mm 52mm 4.0mm 2.0mm D .31 (140)
209-609 20–40mm 0.01mm ±0.03mm 80mm 6.0mm 1.2mm A .44 (200)
209-655 30–40mm 0.01mm ±0.02mm 57mm 4.5mm 2.0mm A .31 (140)
209-600 30–50mm 0.01mm ±0.03mm 80mm 6.0mm 1.2mm A .44 (200)
209-656 40–50mm 0.01mm ±0.02mm 57mm 4.5mm 2.0mm A .31 (140)
209-884 40–60mm 0.01mm ±0.03mm 80mm 9.0mm 1.3mm A .44 (200)
209-885 50–70mm 0.01mm ±0.03mm 80mm 9.0mm 1.3mm A .44 (200)
209-886 60–80mm 0.01mm ±0.03mm 80mm 9.0mm 1.3mm A .44 (200)
209-887 70–90mm 0.01mm ±0.03mm 80mm 9.0mm 1.3mm A .44 (200)
209-888 80–100mm 0.01mm ±0.03mm 80mm 9.0mm 1.3mm A .44 (200)
209-894* 60–130mm 0.01mm ±0.03mm 80mm –– –– A .44 (200)
*Interchangeable contact point (additional anvil 5pcs.) with ball point 1mm dia
R-116
R-117 (2003) full size 12/9/03 2:06 PM Page 1
THICKNESS GAGES
.04" DIA.
steel ball
209-101
209-111
209-115 .09"
209-101
Specifications
Dial Caliper Gages
Inch
Dimensions
Order No. Range Graduation Accuracy A B C D
209-111 .4"–1.4" .001" ±.002" .189" .090" .189" .090"
209-113 1.2"–2.2" .001" ±.002" .268" .169" .669" .571"
209-115 2.0"–3.0" .001" ±.002" .386" .299" .453" .386"
Metric
Dimensions
Order No. Range Graduation Accuracy A B C D
209-101 10–35mm 0.025mm ±0.04mm 4.8mm 2.3mm 4.8mm 2.3mm
209-103 30–55mm 0.025mm ±0.04mm 6.8mm 4.3mm 17.0mm 14.5mm
209-105 50–75mm 0.025mm ±0.04mm 10.0mm 7.6mm 11.5mm 9.8mm
R-117
R-118 (2003) full size 12/9/03 2:06 PM Page 1
THICKNESS GAGES
7309
Metric
Specifications
Pocket Thickness Gages
Inch
Measuring
Order No. Range Resolution Accuracy Force Range/Rev Mass
7308 0–.4" .001" ±.001" 0.2N or less .1" .19lbs
Metric
Measuring
Order No. Range Resolution Accuracy Force Range/Rev Mass
7309 0–10mm 0.01mm ±0.015mm 0.2N or less 1.0mm .19lbs
R-118
R-119 (2003) full size 12/9/03 2:07 PM Page 1
SNAP GAGES
Snap Gages
Series 201
201-806
with IDC
(543-252B)
201-803
201-807
with Dial Indicator
(2803B-10)
Features
SLIM HANDLE TYPE ANATOMIC HANDLE TYPE
These versatile, spring-loaded gages can perform a
MAX.
wide variety of precision measuring jobs with speed and
MIN.
efficiency. They can be equipped with many different dial
A
or Digimatic indicators.
A
Additionally, when Digimatic indicators are used, data
output is available for SPC analysis. C
D
C
Options B B
210-806, 201-807
• Must select measuring indicator 210-801, 201-802, 201-803
R-119
R-120 (2003) full size 12/15/03 1:17 PM Page 1
SNAP GAGES
Snap Gages
Series 201
201-151
with Indicator
2803FB-10
Features
• Designed for quick inspection of diameters of cylinders
and shafts in machining processes.
• Wide (.53"x.47"), flat carbide anvils.
• Both front edges of the anvil are chamfered for
easy insertion.
• Accepts all Dial Indicators and Electronic Gages with
.375" diameter mounting stem.
• Anvil movement .080"
• Accuracy
Parallelism .0002"
Flatness .00004"
Repeatability .0001"
Specifications
Snap Gages (Without Dial Indicator)
Inch
Measuring Dimension Dimension
Order No. Range Force A B
201-151 0–1" 15±3N .55" 1.69"
201-152 1–2" 15±3N .86" 2.63" _
1 0+1
2 2
201-153 2–3" 15±3N 1.45" 3.66" 3
3
201-154 3–4" 15±3N 2.00" 4.64" 4
1µm
4
201-155 4–5" 15±3N 2.63" 5.67" 5 5
201-156 5–6" 15±3N 3.15" 6.65" 6 .8
.6 .4
.2
6
SHOCK
JEWELS
PROOF
6
7
1.0 0
201-157 6–7" 15±3N 3.66" 7.67" 7
8 8
201-158 7–8" 15±3N 3.93" 8.66" 9 10 9
201-159 8–9" 15±3N 4.37" 9.72"
201-160 9–10" 15±3N 4.92" 10.59" 2109F-11
201-161 10–11" 15±3N 5.51" 11.53"
201-162 11–12" 15±3N 6.02" 12.63"
R-120
R-121 (2003) full size 12/9/03 2:08 PM Page 1
TEST INDICATORS
513-443
White Face 513-443-06
Black Face
Features
Mitutoyo introduces three new Series 513 dial indicators, • 20° tilted dial face for easy reading
each available in white, black or blue dial face colors. • Anti-magnetic characteristics.
Each indicator features:
• Smooth spindle movement for increased measuring
accuracy.
• Water and dust resistant one-piece black bezel and
hard coated crystal for improved durability
Dimensions
Complete
Basic
ø3/8" stem
190321
ø5/32" stem
Nut 190318 Square arm
Specifications 190322 900306
Truetest TM
Test Indicators
Inch
Range Per Dial Order No. Wide Range Dimension
Graduation Revolution Range Reading Basic Complete Accuracy L Remarks
White Dial
513-442 513-442T
Face
Blue Dial
.0005" .03" .06" 0-15-0 513-442-01 513-442T-01 ±.0005" .78"
Face
Black Dial
513-442-06 513-442T-06
Face
White Face
513-446 513-446T
Long-point
.0005" .03" .06" 0-15-0 ±.0005" 1.33"
Black Face
513-446-06 513-446T-06
Long-point
White Dial
513-443 513-443T
Face
.0001" .008" .016" 0-4-0 ±.0002" .59"
Black Dial
513-443-06 513-443T-06
Face
R-121
R-122 (2003) full size 12/9/03 2:09 PM Page 1
TEST INDICATORS
Inch/Metric
"Combitest" 513-453
513-412
Features
• Anti-magnetic* The most direct gear train design ever applied to Test
• Jeweled bearings Indicators means—higher level of sensitivity, reliability,
• No-clutch structure repeatability and accuracy throughout tool life.
• Water and dust resistant Structure
• Glare-free crystal with scratch-resistant coating
1 “O” ring incorporated in new bezel design seals
• Metric dial faces in yellow instrument from dust and oil mist.
2 Enlarged pitch of teeth on crown gear improves abili-
ty of indicator to withstand shock.
6
3 Rubber bumpers limit travel of sector gear and pre-
vent damage due to excessive travel.
4 Special alloy of sector gear provides greater resis-
tance to wear, and longer distance between pivot
1
6 points of linkage to better protect against shock.
5
2 3 6 4 5 Carbide point, .078" DIA., is standard.
6 Dovetails, integral with housing, give broad flexibility
Specifications for mounting of instruments.
“Quick-Set” Test Indicators
Inch/Metric
Dial Order No.
Graduation Range reading Basic Complete Accuracy Type Remarks
.0005" .03" 0-15-0 Combitest
513-406 513-406T ±.0005" Horizontal
0.01mm 0.7mm 0-35-0 Anti-Magnetic
Inch
Dial Order No.
Graduation Range reading Basic Complete Accuracy Type Remarks
.0001" .008" 0-4-0 513-403 513-403T ±.0001" Horizontal
.0001" .008" 0-4-0 513-453 513-453T ±.0001" Vertical
.0001" .008" 0-4-0 513-463 — ±.0001" Horizontal Mini-Dial
.0005" .03" 0-15-0 513-402 513-402T ±.0005" Horizontal
.0005" .03" 0-15-0 513-452 513-452T ±.0005" Vertical
.0005" .03" 0-15-0 513-462 — ±.0005" Horizontal Mini-Dial
.0005" .03" 0-15-0 513-282* 513-982* ±.0005" Parallel
.0005" .03" 0-15-0 513-412 513-412T ±.0005" Horizontal Long Point
*513-282 and 513-982 are not anti-magnetic.
Metric
Dial Order No. Measuring
Graduation Range Reading Basic Complete Accuracy Force Remarks
0.002mm 0.2mm 0-100-0 513-405E 513-405T 0.003mm 0.3N or Less Horizontal
0.002mm 0.2mm 0-100-0 — 513-455T 0.003mm 0.3N or Less Vertical
0.01mm 0.5mm 0-25-0 513-414E 513-414T 0.01mm 0.2N or Less Horizontal
0.01mm 0.8mm 0-40-0 513-404E 513-404T 0.008mm 0.3N or Less Horizontal
0.01mm 0.8mm 0-40-0 — 513-454T 0.008mm 0.3N or Less Vertical
0.01mm 1.0mm 0-50-0 513-415E 513-415T 0.01mm 0.2N or Less Horizontal
R-122
R-123 (2003) full size 12/9/03 2:09 PM Page 1
TEST INDICATORS
Horizontal Type
Dimensions Unit: inch
Order Number A B C D E F G H Vertical Type
Dimensions Unit: inch
513-463 .98" .67" .61" 1.10" 1.61" 1.46" .59" .32"
Order Number B C D E F H
513-462 1.00" .65" .61" 1.00" 1.96" 1.81" .78" .32"
513-453, 513-453T 2.01" .59" 1.54" .79" .2" .32"
513-403, 513-403T
.98" .67" .61" 1.54" 1.61" 1.46" .59" .32" 513-452, 513-452T 2.01" .78" 1.54" .79" .2" .32"
513-405E, 513-405T
513-402, 513-402T Dimensions Unit: inch
513-404E, 513-404T .98" .67" .61" 1.54" 1.61" 1.46" .78" .32"
513-406, 513-406T Order Number B C D E F H
513-412, 513-412T .98" .67" .61" 1.54" 1.61" 1.46" 1.33" .32" 513-454T 2.01" .82" 1.54" .79" .2" .32"
513-414E, 513-414T .98" .67" .61" 1.54" 1.61" 1.46" 1.45" .32" 513-455T 2.01" .58" 1.54" .79" .2" .32"
513-415E, 513-415T .98" .67" .61" 1.54" 1.61" 1.46" 1.75" .32"
Universal Type
Parallel Type Dimensions
Dimensions Unit: inch Order Number A B C D E F G
Order Number A B C D E F G H 513-302, 513-942 1.05" .66" 1.96" 1.41" .90" 3.55" .59"
513-282, 513-982 .70" .32" 1.45" 1.45" 2.26" .70" 2.08" .78" 513-304, 513-944 1.05" .66" 1.96" 1.41" .94" 3.59" .59"
R-123
S-01 (2003) full size 12/11/03 3:43 PM Page 1
Miscellaneous
Pocket Magnifiers - Series 183, Precision Sine Plates, Precision Magnetic
Clear Loupe - Series 183 S-2 Sine Plates - Series 986 S-22
Pocket Comparators/Magnifiers w/Reticles Precision Two and Three Dimensional
Series 183 S-2 Vises - Series 986 S-23
Digital Protractor - Series 950 S-3 Magnetic V-Block, Magnetic Adjustable
Precision Levels - Series 960, Levels - Links - Series 986 S-24
Spirit Levels - Series 980 S-4 V-Blocks and Clamps - Series 181 S-24
Digimatic Universal Protractor S-5 Magnetic Hexagonal Holder - Series 986 S-25
Universal Bevel Protractor - Series 187, Magnetic Cubic Blocks - Series 986,
Protractor - Series 187 S-6 Magnetic Holder - Series 986 S-25
Measuring Tapes - Series 980, Frame Permanent Magnetic Chucks -
Winder - Series 980 S-7 Series 986 S-26, 27
Digital Tape Measure - Series 216 S-8 Spring Div., Outside Spring Calipers,
Radius Gages - Series 186, Protractor - Inside Spring Calipers - Series 950 S-28
Series 968 S-9 Small Hole Gages - Series 154 S-28
Radius Gages - Series 186 - Decimal Telescoping Gages - Series 155 S-29
and Fractional S-10 Tap Wrench (T-Handle), Parallel Clamps S-29
Angle Gages - Series 186 S-11 Scribers, Center Punches, Drive Pin
Depth Gage, Adjustable Angle - Punches - Series 985 S-30
Series 950 S-12 Edge & Center Finders, Surface Gage -
Pitch Gages - Series 188, 950 S-12 Series 156 S-31
Thickness Gages - Series 184, 950, Magnetic Lamps - Series 986, Zero-It,
Center Gage - Series 950 S-13 Zero-Setter - Series 950 S-32
Standard Gages - Series 950, Tap & Angle Blocks - Series 981, Adjustable
Drill Gage - Series 950 S-14 Parallels - Series 985 S-33
Drill Point Gage, Thread Gage S-14 MU-Gage Plus, MU-Gage - Series 179 S-34, 35
Knife Edge Straight Edge - Series 528, Roll Calipers - Series 310, Digi-Derm -
Steel Squares - Series 916 S-15 Series 179 S-36
Combination Square Sets - Series 180 S-16 Bench Comparator - Series 162, Bench
Steel Rules - Series 182 S-17, 18 Centers - Series 967 S-37
Semi-Flexible Rules - Series 182, Hook Digital Hand Tachometers - Series 982 S-38
Rules - Series 182 S-19 Datatorq - Series 983 - Digital Torque
Pocket Steel Rule - Series 950 S-19 Wrenches w/SPC output S-39
Demagnetizers - Series 986, Precision Miscellaneous Mitutoyo Products and
Sine Vises - Series 986 S-20 Accessories S-40
Precision Vises - Series 986, Precision
Hydraulic Vise S-21
S-02 (2003) full size 12/8/03 6:48 PM Page 1
OPTICS
Pocket Magnifiers
Series 183
183-201
Features
• A handy instrument that is suitable for inspecting metal
surfaces and shear and unevenness in offset printing.
183-202
Specifications
Order No. Magnification
183-201 25X
183-202 25X
183-203 50X 183-203
Clear Loupe
Series 183
183-301
Features
• Drawtube is made of acrylic resin for clear image of 183-302
the workpiece.
• Drawtube is removable for use as a magnifying glass.
183-101
Specifications
Order No. Magnification 183-121
183-301 7X 183-131
183-302 10X 183-303
183-303 15X
Pocket Comparators/
Magnifiers with Reticles
Series 183
Features
• By replacing reticles (optional), dimensional, angle, and
other types of measurements can be performed.
Specifications
Order No. Magnification
183-101 8X
183-121 9X
183-131 10X
Illumination
950757
Attachment
S-2
S-03 (2003) full size 12/17/03 9:21 AM Page 1
DIGITAL PROTRACTOR
Digital Protractor
Series 950
Features
• Full 360° range (90° x 4).
• Machined aluminum frame.
• Alternate reference (zero).
• Reading hold.
• Simple calibration requiring no special fixtures.
• Display remains upright to view at all angles.
(950-315, Pro 360 Model). 950-315
• RS232C output. (950-316 Pro 3600 Model).
DIMENSIONS
6.015"
1.215"
ON/OFF
HOLD HOLD
ZERO
1.9"
ALT
ALT
0.0° ZERO
140°
4.125"
(Distance between two 6-32 tapped holes)
Optional Accessories
950-316
Order No. Description
64PPP794 Magnetic base
50AAA983 RS-232C Output cable w/foot switch
Specifications
Order No. 950-315 950-316 50AAA983
Model Pro 360 Pro3600 RS-232C Output Cable
Range 360° (90°x4) 360° (90°x4) with foot switch 10P-25P
Resolution 0.1° 0.01° (0° to 9.99°)
DB25, FEMALE
0.1° (10° to 90°) TO PC OR INTERFACE UNIT
Accuracy ±0.1°Level ±10°, Plumb ±10° ±0.05° (0° to 10°)
±0.2° Maximum error ±0.1° (80° to 90°)
±0.2° (10° to 80°) 2m
Repeatability ±0.1° ±0.05°
3m
Cross Axis Error Minimal
FOOT SWITCH
Battery Life 500 Hrs. Standard 9-Volt Battery
Temperature
Operation -5°C to 50°C (23° to 122°F)
Storage -20°C to 65°C (-4°F to 149°F)
Weight 289g (10.2oz.) 295g (10.4oz.)
Output N/A RS-232C Compatible TO DIGITAL PROTRACTOR
Standard Accessories Pouch Plastic Box
±Represents clockwise or counter-clockwise slope.
S-3
S-04 (2003) full size 12/8/03 6:52 PM Page 1
LEVELS
Precision Levels
Series 960
MITUTOYO’s new Series 960 Precision Levels have high
precision longitudinal and transverse vials which make it
possible to check or level surfaces to very high accura-
cies. An exclusive MITUTOYO Adjustment Screw per-
mits readjustment of the levels after long usage. Levels
are made of high quality cast iron and feature precisely
ground V (140°) surfaces. Furnished with a fitted wood-
en case.
Specifications
Precision Levels
Dimensions 960-612
Order No. Sensitivity Accuracy W D H
960-611 .0012"/12" ±.0006" 7.87" 1.73" 1.50"
960-612 .0006"/12" ±.0003" 7.87" 1.73" 1.50"
960-613 .00024"/12" ±.00017" 7.87" 1.73" 1.50"
Levels
(Not available in Canada.)
Specifications
Spirit Levels
Dimensions
Order No. W D H Remarks 980-508
One plumb tube and
980-501 11.81" .87" 1.93"
one level tube.
980-502 23.62" .87" 1.93" Aluminum housing.
980-503 35.43" .87" 1.93" Shockproof vials.
980-504 47.24" .87" 1.93"
980-506
Dimensions
Order No. W D H Remarks
Extruded aluminum
980-505 11.81" 1.10" 2.32"
housing. 980-502
Factory set plumb and
980-506 23.62" 1.10" 2.32"
horizontal vials.
980-507 35.43" 1.10" 2.32" Angle setting vial.
Dimensions
Order No. W D H Remarks
980-508 23.62" 1.06" 2.44" Aluminum housing.
Two plumb, one
980-510 47.24" 1.06" 2.44" horizontal, one
adjustable vials.
S-4
S-05 (2003) full size 12/16/03 11:03 AM Page 1
PROTRACTORS
187-552
Features
• Digimatic Universal Protractor with output function.
• Programmable presetting point.
• Interchangeable measuring face on the blade.
• Can be attached to Height gages.
• Battery life: 2000 hours.
• Product conforming to the EMC directive.
S-5
S-06 (2003) full size 12/16/03 11:05 AM Page 1
PROTRACTORS
Features
• Hardened stainless steel, rust and wear resistant for
long life.
• Flush-reading, no parallax error, gives a high degree of 187-904
accurate measurements.
• With Magnifier glass for easier and faster reading.
Specifications
Universal Bevel Protractors
Graduation
Order No. Dial Vernier Remarks
with 6" blade (187-104)
187-904 1° 5 min and Clamp box for Inch
Height Gages (950749) Accuracy
with 12" blade (187-103) Straightness (4+L/50) µm
187-906 1° 5min and Clamp box for Inch Parallelism (4+L/50) µm
Height Gages (950749)
Vernier Accuracy ±5'
Universal Bevel Protractor "L" is in mm
Accessories and Parts
Order No. Remarks
187-103 12" Blade.
187-104 6" Blade.
187-105 Acute angle attachment
950749 Clamp box for Inch Height Gages
950750 Clamp box for Metric Height Gages 187-105
Acute Angle Attachment
Protractor
Series 187
The bevel protractor consists of three sheets of stainless 187-201
steel, the middle one of which is made for angle mea-
surements.
Specifications
Bevel Protractor
Order No. Graduation Remarks
Center black knob locks the
blade position
187-201 1°/5 min
Protractor Graduation: 0°–90°,
90°–0°
S-6
S-07 (2003) full size 12/16/03 11:08 AM Page 1
MEASURING TAPES
Measuring Tapes
Series 980 980-635
(Not available in Canada.)
Features
• Hardened, tempered high phosphated to prevent rust
or corrosion.
• Nylon coating.
• Quick rewind handle.
980-131
Frame Winder
Series 980 980-160
(Not available in Canada.)
Features
• Hardened, tempered high carbon steel tape, phosphat-
ed to prevent rust or corrosion.
• Tape is sheathed in heavy duty nylon.
• Quick rewind handle.
Specifications 980-638
Measuring Tapes
Inch/Metric
Unit of Width of Blade
Order No. Length Measure Blade Color Remarks
980-131 100 ft in/ft 3/8" white Tough ABS plastic housing
980-140 50 ft in/ft 1/2" white Tough ABS plastic housing
980-631 66 ft/20m in/mm 1/2" yellow Tough ABS plastic housing
980-632 100 ft/30m in/mm 1/2" yellow Tough ABS plastic housing
980-635 100 ft/30m in/mm 1/2" white Tough ABS plastic housing
Frame Winder Tapes
Unit of Width of Blade
Order No. Length Measure Blade Color Remarks
980-160 100 ft in/ft 3/8" white Tough ABS plastic housing
980-161 150 ft in/ft 3/8" white Tough ABS plastic housing
980-630 100ft/30m in/mm 1/2" yellow Tough ABS plastic housing
Measuring Tapes
Unit of Width of Blade
Order No. Length Measure Blade Color Remarks
980-637 66 ft/20m in/mm 10mm white Tough ABS plastic housing
980-638 100 ft/30m in/mm 10mm white Tough ABS plastic housing
S-7
S-08 (2003) full size 12/16/03 11:09 AM Page 1
MEASURING TAPES
1.73"(44)
.04"(1) 1.61"(40.8) Unlock lever
in(decimal)/in(fraction)/mm select button
Battery cap
ZERO-set
button
2.95"(75)
3.31"(84)
ON/OFF
button
.75"(19)
HOLD button
belt hook 4"(101.6)
hook
Reference surfaces
Specifications
Order No. 216-380
Model TD-S551C
Measuring range(L) 216" / 18' / 5.5m
Blade width 1"
Resolution .01" / 1/32" / 0.1mm
Instrumental error ±0.06" / ±1/16" / ±1.5mm
Scale graduation Inch: 0–6" 1/32", 6–216" 1/16" / Metric: 1mm
Accuracy of the scale graduation ±1.5mm/0.6"
Battery Lithium cell CR2032 (05SAA217)
Battery life 2500 hours
Mass 0.86 lbs. (390g)
L=Measuring length. (m)
S-8
S-09 (2003) full size 12/8/03 7:04 PM Page 1
RADIUS GAGES/PROTRACTORS
Radius Gages
Series 186
Features
• Each radius gage has five measuring locations.
• Each location is identified with its particular radius.
• Decimal radius gages available up to 1".
• Fractional radius gages available up to 1".
• Accuracy: ±.0016"/0.04mm"
Order No.Range
186-101 1/32–1/4" .......................................................30 leaves 186-102
186-102 17/64–1/2" .....................................................32 leaves
186-103 1/32–17/64" ...................................................16 leaves
186-104 9/32–33/64" ...................................................18 leaves
186-105 1–7mm...........................................................34 leaves
186-106 7.5–15mm......................................................32 leaves
186-107 15.5–25mm....................................................30 leaves
Protractor 968-201
Series 968 –
with Rectangular Base
Basegular Base Protractor’s scale plate and indicator blade are
made entirely of stainless steel. (968-201) (968-202 and 986-
203 Satin chrome finish). With 6" arm.
Specifications
Rectangular Base Protractor
Order No. Graduation Remarks
968-201 1° Protractor Graduation: 0°–90°,
90°–180°, 180°–90°, 90°–0°
968-202 1° Semi-Circle: 0°-180°, 180°-0°
968-203* Rectangle: 0°-180°, 180°-0°
*6” Arm with graduation rule.
968-202
3.70"
00
00
00
00
.55"
2.36"
00
00
00
00
00
00
00
00 00
R45
00
MADE IN JAPAN 00
00
00
6.18"
8.03"
.05"
968-203
S-9
S-10 (2003) full size 12/8/03 6:44 PM Page 1
RADIUS GAGES
Radius Gages
Series 186
Decimal Radius Gages to 1"
Fractional Radius Gages to 1"
MITUTOYO Radius Gages are recommended for check-
ing or laying out concave or convex radii. An individual
gage for each dimension makes it possible to verify
radius or fillet dimensions easier, faster and more accu-
rately in machining, layout, inspection and pattern-mak-
ing work. The measuring surfaces are precisely finished
with smooth, accurate edges. The Radius Gages are 186-901
available separately or in six handy sets.
Each Radius Gage has five measuring locations, and it
is identified with its particular radius dimensions. The
gages have a satin or dull-chrome finish.
The Holding Cases, provided to protect the sets of
Radius Gages, have indexed pockets to facilitate the
selection of the proper size gage. A 4" long holder is fur-
nished with Set No. 186-901 to make it possible to
check radii in confined or hard-to-reach locations.
Specifications Accuracy: ±.0016"/0.04mm
Radius Gage
Order No. No. of Leaves Sizes
1/64"–17/64" by 64ths 1
186-901 25
and 9/32"–1/2" by 32nds
186-903 17 1/64"–17/64" by 64ths
5
186-904 8 9/32"–1/2" by 32nds 2
186-905 8 9/16"–1" by 16ths
3
.010–.030" by .005" 4
.040–.100" by .010"
186-906 26 .120–.220" by .020"
.240–.300" by .020" 5 concave and convex radii per each leaf.
.350–.500" by .050"
186-907 10 .550–1" by .050"
S-10
S-11 (2003) full size 12/8/03 6:47 PM Page 1
ANGLE GAGES
Angle Gages
Series 186
Features
• Manufactured from stainless steel, satin finished.
• 18 individual gages for easy use.
• Eight gaging surfaces per gage.
• Precision finished edges for accurate checking.
• Each gage checks primary, 1/2 primary and comple-
mentary angles.
• Sharp cornered workpieces can be checked at all
8 angles except below 50° on primary angle 2.
• Quick and accurate inspection of angles and I.D.
or O.D. chamfers—in or out of the machine.
• Positioning of lathe tools for chamfers.
• Inspecting angles on ground form tools and cutters.
• Fast set-ups and fixturing of workpieces.
• Eliminates time consuming measuring set-ups.
Specifications
Angle Gages
Set Order No. Description No. of Leaves 5
2 3
186-910 Angle Gage Set w/case 18
8
Individual Part No. 1
Inch 7 6 4
Primary 1/2 Primary Complementary
Angles 1, 2, 3, 4 are primary
Part No. Angle Angle Accuracy Angle
Angles 5, 6, are complementary
051000* 5° 2° 30' ±5' 175° Angles 7, 8 are 1/2 primary
051001* 10° 5° ±5' 170°
051002* 15° 7° 30' ±5' 165°
051003 20° 10° ±5' 160°
051004 35° 12° 30' ±5' 155°
051005 30° 15° ±5' 150°
051006 35° 17° 30' ±5' 145°
Gaging of angles of adjoining Gaging of the countersink
051007 40° 20° ±5' 140°
inside/outside diameters or angles of drilled and
051008 45° 22° 30' ±5' 135° flat surfaces. tapped holes.
051009 50° 25° ±5' 130°
051010 55° 27° 30' ±5' 125°
051011 60° 30° ±5' 120°
051012 65° 32° 30' ±5' 115°
051013 70° 35° ±5' 110° Gaging of primary and com-
051014 75° 37° 30' ±5' 105° plementary angles from a
051015 80° 40° ±5' 100° surface plate.
051016 85° 42° 30' ±5' 95° Gaging of I.D. and O.D.
051017 90° 45° ±5' 90° chamfers.
051018 Vinyl Case Included angles are easily
* Angle 2 omitted verified.
S-11
S-12 (2003) full size 12/8/03 6:49 PM Page 1
GAGES
Pitch Gages
Series 188, 950
Features
• Pitch size is stamped on each gage.
• Whitworth, Unified and Metric Pitch Gages.
Specifications
Order No. Range Composition of Gages
Whitworth Screw Pitch Gages (55°)
188-101 4 - 42 TPI 4, 41/2, 5, 51/2, 6, 7, 8, 9, 10, 11, 111/2,
(30 leaves) 12, 13, 14, 15, 16, 18, 20, 22, 24, 26,
188-102
27, 28, 30, 32, 34, 36, 38, 40, 42 TPI
188-102 4, 41/2, 5, 51/2, 6, 7, 8, 9, 10, 11, 12, 13, 14,
4 - 60 TPI
(28 leaves)
16, 18, 19, 20, 22, 24, 25, 26, 28, 30,
32, 34, 36, 40, 48, 60 TPI
Unified Screw Pitch Gages (60°)
188-111 4 - 42 TPI 4, 41/2, 5, 51/2, 6, 7, 8, 9, 10, 11, 111/2,
(30 leaves) 12, 13, 14, 15, 16, 18, 20, 22, 24, 26,
27, 28, 30, 32, 34, 36, 38, 40, 42 TPI
950-253 4 - 84 TPI 4, 41/2, 5, 51/2, 6, 7, 8, 9, 10, 11, 111/2,
(51 leaves) 12, 13, 14, 15, 16, 18, 20, 22, 24, 26,
27, 28, 30, 32, 34, 36, 38, 40, 42, 44,
46, 48, 50, 52, 54, 56, 58, 60, 62, 64,
66, 68, 70, 72, 74, 76, 78, 80, 82, 84 TPI
Metric Screw Pitch Gages (60°)
188-130 0.35 - 6mm 0.35, 0.4, 0.45, 0.5, 0.6, 0.7, 0.75, 0.8,
(22 leaves) 1, 1.25, 1.5, 1.75, 2, 2.5, 3, 3.5, 4, 4.5,
5, 5.5, 6mm and 60° angle gage
188-122 0.4 - 7mm 0.4, 0.5, 0.7, 0.75, 0.8, 0.9, 1, 1.25, 1.5,
(21 leaves) 1.75, 2, 2.5, 3, 3.5, 4, 4.5, 5, 5.5, 6, 6.5,
7mm
188-121 0.4 - 7mm 0.4, 0.5, 0.75, 1, 1.25, 1.5, 1.75, 2, 2.5,
(18 leaves) 3, 3.5, 4, 4.5, 5, 5.5, 6, 6.5, 7mm
Metric and Unified Screw Pitch Gage Set (60°)
188-151 0.4 - 7mm Set of 188-122 and 188-111
4 - 42 TPI
(51 leaves)
S-12
S-13 (2003) full size 12/9/03 10:15 AM Page 1
GAGES
Thickness Gages
Series 184, 950
950-251
Specifications
Thickness Gages – Inch
Order No. Range Type of Blade Blade Length Composition of leaves
184-101 .0015"-.015" Tapered 3" .0015, .002, .003, .004, .006, .008,.010, .012, .015"
(9 leaves)
184-102 .004" - .025" Tapered 3" .004 thru .025" by .001" step
(22 leaves)
184-405 .002" - .025" Straight 3" .002, .003, .004, .005, .006 ,.008, .010, .012, .013,
(15 leaves) .015, .018, .019, .020, .022, .025
184-406 .0015" - .025" Tapered 3" .0015 thru .0055" by .0005" step, .006 thru .010"
(18 leaves) by .001" step plus .012, .015, .020, .025"
950-251 .002" - .035" Straight 3" .002 thru .018" by .001" step
(26 leaves) 1/2" width at tip plus .022, .024, .025, .028, .030, .032, .035"
950-252 .0015" - .025" Tapered 3" .002 thru .025" by .001" step
(26 leaves) 1/4" width at tip plus .0015, .0025"
950-254 .0015" - .200" Straight 3" .0015, .002, .003, .004, .006, .008, .010, .012, .015,
(15 leaves) 1/2" width at tip .020, .030, .040, .075, .100, .200"
950-255 .0015" - .200" Straight 4 1/2" .0015, .002, .003, .004, .006, .008, .010, .020, .030,
(13 leaves) 1/2" width at tip .040, .075, .100, .200"
950-256 .0015" - .015" Straight 6" .0015, .002, .003, .004, .008, .010, .012, .015"
(8 leaves) 1/2" width at tip
Thickness Gages – Metric
184-302 0.03 - 0.5mm Straight 150mm 0.03 thru 0.1mm by 0.01mm step
(13 leaves) plus 0.15, 0.2, 0.3, 0.4, 0.5mm
184-307 0.03 - 0.5mm Straight 100mm 0.03 thru 0.1mm by 0.01mm step
(13 leaves) plus 0.15, 0.2, 0.3, 0.4, 0.5mm
184-303 0.05 - 1mm Straight 150mm 0.05 thru 0.15mm by 0.01 mm step
(28 leaves) 0.2 thru 1 mm by 0.05mm step
184-313 0.05 - 1mm Straight 100mm 0.05 thru 0.15mm by 0.01mm step
(28 leaves) 0.2 thru 1mm by 0.05mm step
184-306 0.05 - 0.8mm Straight 100mm 0.05 thru 0.2mm by 0.05mm step
(10 leaves) 0.3 thru 0.8mm by 0.1mm step
Center Gage
Series 950
Features
• Hardened with lapped edges and notches.
• Meets requirements of the American National
and US 60° Standards.
• Scales with 14ths and 20ths graduations
provided on one side, 24ths and 32nds on
reverse side. 950-201
S-13
S-14 (2003) full size 12/16/03 10:59 AM Page 1
GAGES
Standard Gages
Series 950
Specifications 950-203
Standard Gages
950-202
Inch
Order No. Description Size
950-202 Am. Standard Wire Gage Gage No. 0–36
950-203 U.S. Standard Wire Gage Gage No. 0–36
Thread Gage
Features
Used for grinding and setting tools when cutting acme threads
whose side have an inclination of 14-1/2° (29° included angle)
Specifications
Order No. Description
950-257 29° acme screw thread gage 950-257
S-14
S-15 (2003) full size 12/8/03 6:56 PM Page 1
Knife Edge
Straight Edge 528-103
Series 528 916-402
The test edge is approximately .004" in thickness, a
cross section of which has radius to provide a straight
line contact with the work surface. Straightness is
±.00005".
For ease of inspection, the blade is dyed in black, and 916-401
the upper edge is covered with a grip plate. The acute
angle is 30 degrees. 916-100
528-104
Specifications
Knife Edge Straight Edge
Inch 916-424
Length Order No. Remarks
4" 528-102 with protective cover 916-423
6" 528-103 with protective cover
8" 528-104 with protective cover
10" 528-105 with protective cover
S-15
S-16 (2003) full size 12/8/03 6:58 PM Page 1
S-16
S-17 (2003) full size 12/8/03 7:00 PM Page 1
RULES
Steel Rules
Series 182
Features 182-125
• Satin chrome finish.
• Stainless tempered.
• Black chrome rule.
182-110
Specifications
Wide Rigid Rules (Thickness 3/64")
Black Chrome
Rule
Order No. Order No. Size Graduations Width Accuracy (Length)
182-101 182-109 6"(4R) 1/8 1/16 1/32 1/64th 3/4"
S-17
S-18 (2003) full size 12/8/03 7:02 PM Page 1
RULES
Steel Rules
Series 182
Features 182-265
• Satin chrome finish.
• Stainless tempered. 182-223
Specifications
Full-Flexible Rules (Thickness 1/64")
Black Chrome
Rule
Order No. Order No. Size Graduations Width Accuracy (Length)
182-201 182-212 6"(4R) 1/8 1/16 1/32 1/64th 1/2"
S-18
S-19 (2003) full size 12/8/03 7:05 PM Page 1
RULES
Semi-Flexible Rules
Series 182
(Thickness 1/64")
Features 182-304
• Engraved on frontside only.
Specifications
Inch/Metric
Order No. Size Graduations Width Accuracy (Length)
182-301 4" x 100mm 1/2mm 1mm 1/32 1/64 1/16th 5/8"
182-302 6" x 150mm 1/2mm 1mm 1/32 1/64 1/16th 5/8"
+.004"/–.002" (+0.1mm/–0.05mm)
182-304 10" x 250mm 1/2mm 1mm 1/32 1/64 1/16th 5/8"
182-305 12" x 300mm 1/2mm 1mm 1/32 1/64 1/16th 5/8"
182-307 20" x 500mm 1/2mm 1mm 1/32 1/64 1/16th 5/8" +.006"/–.003" (+0.15mm/–0.075mm)
182-309 40" x 1000mm 1/2mm 1mm 1/32 1/64 1/16th 5/8" +.008"/–.004" (+0.2mm/–0.1mm)
Hook Rules
Series 182
(Thickness .040")
Features
• Hardened and tempered tool steel.
• Hard chrome finish.
• Furnished with adjustable hook.
Specifications 182-421
S-19
S-20 (2003) full size 12/8/03 6:45 PM Page 1
Demagnetizers
Series 986
(Not available in Canada.)
A
B
E
Elevating Knob
Specifications
Precision Sine Vises D
Inch
Clamping Maximum Dimensions
Order No. Capacity Angle A B C D E
986-121 3.54" 45° 2.75" 3.72" 1.18" 6.69" 3.13"
986-122 4.72" 45° 3.54" 4.51" 1.57" 8.27" 3.76"
986-124 3.77" 45° 2.95" 3.72" 1.18" 6.30" 3.13"
S-20
S-21 (2003) full size 12/8/03 6:47 PM Page 1
PRECISION VISES
Precision Vises
Series 986
(Not available in Canada.)
Specifications
Precision Vises
Clamping Dimensions
Order No. Capacity A B C D 986-111
986-106 3.15" 6.30" 2.75" 2.44" 1.18" A
986-107 4.72" 8.26" 3.54" 2.95" 1.57"
Clamping Dimensions B
Order No. Capacity A B C D
986-101 3.15" 6.30" 2.75" 2.44" 1.18"
986-102 4.72" 8.26" 3.54" 2.95" 1.57"
986-111 1.22" 3.54" 2.36" 1.96" .98" D
C
986-112 5.90" 11.22" 4.72" 3.54" 1.57"
Precision
Hydraulic Vise
(Not available in Canada.) 986-116
Specifications
Precision Hydraulic Vise
Clamping Dimensions D
Order No. Capacity A B C D C
S-21
S-22 (2003) full size 12/8/03 6:49 PM Page 1
SINE PLATES
Features
• Parallelism within .0001"/4".
• Squareness within .0002"/4". B
986-126
• Roller center distance within .0001".
• Rollers hardened and ground to within
.00005" of same diameter.
• Supplied with plastic case.
C
5"
Elevating Knob
Specifications
Precision Sine Plates
Plate Maximum Dimensions
Order No. Size Angle A B C Remarks
Sine Function:
986-126 5.90" x 5.90" 45° 5.90" 5.90" 2.54"
One Axis
Precision Magnetic
Sine Plates A
Series 986
(Not available in Canada.)
B
Features 986-127
• Parallelism within .0001"/4".
• Squareness within .0002"/4".
• Roller center distance within .0001". 1.3"
Specifications
Precision Magnetic Sine Plates
Plate Maximum Dimensions
Order No. Size Angle A B C Remarks
Sine Function:
986-127 5.90" x 5.90" 45° 5.90" 5.90" 3.84"
One Axis
S-22
S-23 (2003) full size 12/8/03 6:51 PM Page 1
PRECISION VISES
Series 986
(Not available in Canada.)
Features
• Precision Two Dimensional Vises, Order Nos. 986-136
and 986-137 are basic vises for precise cutting, grind-
ing and engraving operations. Precision Vise No. 986-
137 has hydraulic leverage for clamping pressure.
• All Precision Vises are made of hardened (RC-60)
alloy tool steel. Stress relieved through sub-zero
treatment, to assure dimensional stability and high
accuracy over long lasting service.
• Parallelism within: .0001"/4".
• Fine adjustment screw provided on the swiveling base.
• 5-minute vernier is attached to graduation of the
rotation and angle.
• Supplied with plastic case.
E 20 10 0 10 20
60
60
50
50
40
30 40 80 90 80 70
20 10 30 70
0 10 20 60
60 50
50
20 10 0 10 20
A B
F
50
50
60 60
70
80 90 80 70
Specifications
Precision Two and Three Dimensional Vises
Clamping Dimensions
Order No. Capacity A B C D E F
986-136 3.15" 4.33" 2.75" 6.30" 1.18" 5.39" 7.08"
986-137 10.72" 6.30" 4.72" 11.22" 1.56" 8.26" 10.63"
S-23
S-24 (2003) full size 12/8/03 6:54 PM Page 1
MAGNETIC V-BLOCKS
Magnetic V-Block
Series 986
(Not available in Canada.)
Specifications B1 A
Magnetic
Adjustable Links
Series 986
(Not available in Canada.) 986-256
Two magnetic holders, linked together, provide a means
of mounting workpieces at any angle to facilitate assem-
bly procedures or operations such as welding. Link with
V-groove holders (Order No. 986-254) will adhere to
and/or hold curved as well as flat surface.
Specifications
Magnetic Adjustable Links 986-254
Order No. Pull Mass Dimensions Remarks
986-251 22.0 lbs 1.43 lbs .98" x 2.28" x .98" x 5.0"
986-254 176.3 lbs 4.41 lbs 1.81" x 2.36" x 1.96" x 6.10" w/ON/OFF switch
986-256 77.1 lbs 5.51 lbs 5.90" x 5.90" x 1.37" 90°
Magentic V-Blocks
Accuracy Holding
Order No. (over all) Pull Capacity
181-146 .0006" 132.2 lbs 1 Piece ø2"
2.99"
S-24
S-25 (2003) full size 12/8/03 6:56 PM Page 1
MAGNETIC HOLDERS
Magnetic
Hexagonal Holder
Series 986
(Not available in Canada.)
Multiple surfaces and angles require a holder for firmly
986-261
mounting oddly shaped pieces, as well as bars and
plates, during measuring, scribing, welding and drilling
1.22"
operations. Angles of 45°, 90° and 135°. Lever turns 1.37"
"
25
4.
magnetic force on or off.
°
90
4.25"
Specifications
Magnetic Hexagonal Holder
Order No. Pull Mass 120°
.59" .59"
986-261 176.3 lbs 12.3 lbs
5.35"
Magnetic
Cubic Blocks
Series 986
(Not available in Canada.)
Blocks numbered 986-301, 302, and 307 feature mag-
netic forces in the two V grooves on the top surface, in
addition to the balance of the top surface and two side
surfaces. 986-301 986-303
Blocks numbered 986-303, 304, 305 and 306 have mag-
netic forces in the V groove on the top and the balance TRI-SURFACE ATTRACTING TYPE SINGLE SURFACE ATTRACTING TYPE
of the top surface. A B A
D D D B
Specifications 90° 90°
986-322 986-321
Magnetic Holders
Series 986
Specifications
Magnetic Holders (series 986)
Order No. Pull Mass Dimensions Remarks
986-311 1.7 lbs .02 lbs .39" (DIA) x .59"
986-312 6.6 lbs .02 lbs .59" (DIA) x .59"
986-313 11.0 lbs .09 lbs .78" (DIA) x .78"
Connect bolt hole
986-314 22.0 lbs .13 lbs .98" (DIA) x .98"
M6 (P = 1.0mm) 986-313
986-315 66.1 lbs .35 lbs 1.57" (DIA) x 1.37"
Connect bolt hole 986-311
M8 (P = 1.25mm)
986-321 11.0 lbs .26 lbs .98" x .98" x .98"
986-322 22.0 lbs .55 lbs .98" x 2.28" x .98"
S-25
S-26 (2003) full size 12/8/03 6:59 PM Page 1
MAGNETIC CHUCKS
Permanent Magnetic
Chucks
Series 986
(Not available in Canada.) 986-204
Strong Rectangular Type Chucks
Thicker workpieces will be held firmly, during grinding
operations, with this coarser pitch, more powerful mag-
netic chuck.
Regular Rectangular Type
Pitchless Chucks
Pitchless chucks are recommended for use when grind-
ing small and/or thin workpieces as small as 4mm DIA.,
as thin as 0.2mm.
ød 986-211
A
off on
C
D E
Specifications
Permanent Magnetic Chucks—Strong Rectangular Type
Inch
Order No. Mass A B C D E (DIA) d
986-201 12.1 lbs 3.93" 5.55" 2.28" 1.22" 7.28" .39"
986-202 17.6 lbs 3.93" 8.38" 2.28" 1.22" 10.23" .39"
986-203 22.0 lbs 4.92" 8.38" 2.28" 1.22" 10.23" .39"
986-204 37.4 lbs 5.90" 9.33" 2.36" 1.57" 12.36" .55"
986-205 44.1 lbs 5.90" 11.22" 2.36" 1.57" 14.33" .55"
Regular Rectangular Type Pitchless Chucks
Order No. Mass A B C D E (DIA) d
986-211 5.5 lbs 2.75" 4.29" 1.85" 1.22" 5.51" .39"
986-215 37.4 lbs 5.90" 9.37" 2.36" 1.57" 12.36" .55"
S-26
S-27 (2003) full size 12/8/03 7:01 PM Page 1
Permanent Magnetic
Chucks
Series 986
(Not available in Canada.)
Swivel Rectangular Type Chucks
Jigs, molds and tools can be located at any angle, for
forming or grinding operations, using the swiveling mag-
netic chuck. Installation is simple since no electrical 986-221
power is required, which eliminates the possibility of loss
of accuracy due to increase in temperature. E
Specifications A
D E
S-27
S-28 (2003) full size 12/8/03 7:02 PM Page 1
Spring Dividers,
Outside Spring Calipers, 950-211
950-231
Inside Spring Calipers
Series 950
Specifications
Inside, Outside Spring Calipers, Spring
Dividers
Order No. Range Remarks
950-211 4"
950-212 6"
950-213 8" Spring Dividers
950-214 10"
950-215 12"
950-221 4" 950-221
950-222 6"
950-223 8" Outside Spring Calipers
950-224 10"
950-225 12"
950-231 4"
950-232 6"
950-233 8" Inside Spring Calipers
950-234 10"
950-241
950-235 12"
950-241 4"
Hermaphrodite Caliper
950-242 6"
Specifications
Small Hole Gages
Dimensions
Order No. Range B C D Remarks
154-105 .118–.197" .88" 3.54" .21" D
S-28
S-29 (2003) full size 12/8/03 7:05 PM Page 1
Telescoping Gages
155-903
Series 155 (5/16"~6")
Specifications
Telescoping Gages
Dimensions
Order No. Range A B C D Remarks
155-121 .315–.50" .12" .16" 4.33" .20"
155-122 .50–.748" .14" .20" 4.33" .22"
155-123 .748–1.26" .14" .20" 4.33" .22"
155-124 1.26–2.126" .23" .29" 5.90" .31"
A
155-125 2.126–3.54" .23" .29" 5.90" .31"
155-126 3.54–5.90" .23" .29" 5.90" .31" D
Tap Wrench
T-Handle
(Not available in Canada.)
Specifications
Tap Wrench (T-Handle)
985-122
Order No. Clamping Capacity Remarks
985-121 .118"-.315" with Ratchet 985-121
985-122 .315"-.551" with Ratchet
Parallel Clamps
Features 985-128
• Material: hardened steel.
• Black-oxide finish.
Specifications
W L(max.)
Parallel Clamps
S
Dimensions 985-127
Order No.
H L (Max) W S
985-126 1.96" 1.18" .39" .39"
H
S-29
S-30 (2003) full size 12/16/03 10:55 AM Page 1
Scribers
Series 985 985-111
MITUTOYO provides a full line of scribers to accommodate 985-105
every shop need. All the scribers, with the exception of the
985-105, have tungsten-carbide tips. The 985-105 has a 985-104
diamond tip.
Specifications 985-103
Scribers
Order No. Length Replacement Point 985-102
985-101 6.75" No. 050561
985-102 6.12" — 985-101
985-103 8.87" —
985-104 5.75" No. 050562*
985-105 5.12" No. 050563*
985-111 5.62" No. 050564
*Retractable
Center Punches
Series 985 985-114
Specifications
Center Punches
Order No. Length Replacement Point Remarks 985-112
.68" (DIA),
985-112 5.25" No. 050565
Plastic housing
1.0" (DIA),
985-113 6.0" No. 050566
Metal housing
985-114 3.0" — .31" (DIA)
985-113
985-115 4.0" — .39" (DIA)
985-116 4.3" — .59" (DIA)
985-117 5.0" — .67" (DIA)
S-30
S-31 (2003) full size 12/8/03 6:48 PM Page 1
050102
Specifications
Edge & Center Finders
Order No. Shank (DIA) Tip (DIA) Remarks 050103
050101 3/8" (.375") .20" Edge Type
050102 1/2" (.50") .20" Edge Type
050103 3/8" (.375") .20" Center Type 050104
050104 1/2" (.50") .20" Center Type
050105 .375"/10mm 10mm Edge Type
050105
050106 10mm 10mm Edge Type
050109 1/2" (.50") .50" Edge Type
1/2"
050106
050110 (.50") .20", .50" Double Edge Finder
Surface Gage
Series 156
This Surface Gage has a coarse-adjusting clamp for upright post,
fine-adjusting knob and baked-enamel-finished, hardened-steel base.
The two gage pins provided are held tightly against the base.
The rocker runs the entire length of the base and pivots against a Stems for test indicators
heavy spring, allowing a wide range of fine adjustment, yet holding (optional)
the tip of the scriber firmly.
Stem 102036
Use of a test indicator along with this Surface Gage is recommended. .156"
In addition to the above stems for test indicators, the 156-502
156-502 Surface Gage accepts ø3/8", 5/32" (9.5mm, 4mm) stems.
Stem 190318 and Nut 190322
Features .156"
• Bottom surface, Vee and parallel side edges are ground.
• A pair of gage pins for linear work.
• Fine adjusting knob.
• Suitable as a small transfer stand with MITUTOYO test indicator.
Specifications
Surface Gage
Order Dimension
No. of Scriber Remarks
156-502 Length: 6.9" Base Dimension:
3.4"(W) x 2.4"(D) x 1.3"(H)
(DIA): .157" Post Dimension:
(4mm) Length: 10.2", .44" (DIA)
S-31
S-32 (2003) full size 12/8/03 6:50 PM Page 1
986-281
Magnetic Lamps (without bulb)
Series 986
(Not available in Canada.)
ZERO-IT 950-110
“Zero-It” is specially designed for MITUTOYO Test Indicators with 950-110
Dovetails, and functions as a quick and practical work positioning
device.
Attach “Zero-It” directly to the collet, then zero-in the work position by
reading MITUTOYO Test Indicator. The hardened clamping post con-
sists of three ODs, from top, 1/4", 3/8" and 1/2", and has hardness of
approximately 58 to 60 Rockwell C.
TEST INDICATOR
(Not supplied)
Specifications
Zero-It
Order No. Coarse Fine WORK
950-110 10" 3/8" ZERO IT
ZERO-SETTER
Series 950
Fast and sure establishment of “0” reference point with 950-112
built-in indicator.
Spring loaded setting face to safe guard against damage
from over run.
Body dia. 1.44" (36.5mm)
Wooden case included.
Specifications
Zero-It
Order No. Height Graduation
950-111 1" .0005" 950-111
950-112 25mm 0.01mm
S-32
S-33 (2003) full size 12/8/03 6:52 PM Page 1
Angle Blocks
Series 981
Specifications
Angle Blocks
Order No. Angle Accuracy Remarks
010001 1/4°
010002 1/2°
010003 1°
010004 2° 981-102
010005 3°
010006 4° Hardened steel over
010007 5° ±20 sec HRC 55
010008 10° Precision ground 010012
010009 15° throughout 010011
010010 20° 010010
010009
010011 25° 010008
010012 30° 010007
010013 45°, 45°, 90° 010006
±40 sec 010005
010014 30°, 60°, 90° 010004
010003 010013 010014
Set Order No. Remarks 010002
010001
981-101 10 pc. Set (Order No. 010003-010012)
981-102 12 pc. Set (Order No. 010001-010012)
981-103 2 pc. Set (Order No. 010013-010014)
2 pc. Set 981-103
Adjustable Parallels
Series 985
• Consists of two precision ground pieces which slide • Can be quickly inserted into openings and expanded to
smoothly on each other. exact size, then measured with a micrometer.
• Locked into position by set screws.
S-33
S-34 (2003) full size 12/8/03 6:54 PM Page 1
MU-GAGE PLUS
MU-Gage Plus
Series 179
Ultrasonic micrometer with SPC output
The MU-Gage Plus is high resolution ultrasonic micrometer with
the following features.
Features
1. Lemo quick-disconnect transducer connector.
2. PRB carat lights when unit in probe selection mode.
3. DIF carat lights when unit in differential offset measurement
mode.
4. LT carat lights when display backlight control mode is
enabled.
5. HI/LO carat lights when unit in the HI/LO tolerance
limits/alarm set-up mode.
6. Backlit display
7. Activates scrolling keys to set values in THK, VEL, DIF,
HI/LO, PRB, and LT control options.
8. Scrolling keys.
9. Selects operating mode, THK, VEL, DIF, HI/LO, PRB, and
LT across top of display window.
10. SPC output port.
11. Built-in calibration block for transducer recognition.
12. Power on/off switch. 1
13. Clears displays and erases/resets. 19 2
18 3
14. Sends data in memory to compatible computer or
printer. 4
5
15. Low Battery indicator. 17
16
16. Indicates displayed value outside tolerance limit. 6
17. Over range indicator, exceeding available digits. 15
18. THK carat lights when unit in normal thickness
measurement mode. 14 7
19. VEL carat lights when unit in material velocity mode.
8
13 9
12
Specifications 11 10
MU-Gage Plus Standard Accessories
Order No. 179-207 179-208 Order No. Description
Transducer Thin Metal Thin Plastics 64AAA510 Transducer probe for 179-207 (cable length 4 ft.)
Measuring Range .010–1.000" .005–.200" 64AAA511 Transducer probe for 179-208 (cable length 4 ft.)
0.25–25mm 0.13–5mm 64AAA504 Couplant Bottle (4 0z.)
Resolution .0001"/0.001mm .0001/0.001mm 64AAA512 Screw Driver
Accuracy ±.002" ±.0015" 64AAA513 Plastic Case
Battery 4 pcs. AA Alkaline
Dimension W=3.5" x H=6.25" x D=1.5" Optional Accessories
(89mm x 159mm x 38mm) Order No. Description
Operating Temp +10°F to 120°F (-10°C to 50°C) 64AAA514 Replacement for Probe Tip
Mass .91lbs. (410g) 64AAA515 Replacement Cable for Transducer
Material Type Thin Metal Plastic 64AAA516 Soft case w/strap
936937 SPC Output connecting cable (1m)
965014 SPC Output connecting cable (2m)
S-34
S-35 (2003) full size 12/8/03 6:57 PM Page 1
MU-GAGES
MU-Gage
Series 179
Ultrasonic micrometer with SPC output
The MU-Gage is an ultrasonic instrument for precise thickness
measurement from just one side of a workpiece.
Features
1. Lemo quick-disconnect transducer connector.
2. Battery charger connect/data port
3. Built-in auto-probe zero block
4. Coupling indicator
5. Backlit LCD indicates modes, measurements and icons
6. Lightweight aluminum case
7. Weather resistant sealed keypad
8. POWER key
9. ALRM key enables alarm LEDs
10. SEND key for transmission of readings
11. Numeric keys
12. Material calibration key
13. SCAN key enables rapid scanning and minimum thickness
capture
14. DIFF key enables display of positive or negative difference
to preset value
15. Red and green LED indicators
16. Operator selectable Metric or English units
1
2
3
Specifications
MU-Gage Plus 16 4
standard type.
S-35
S-36 (2003) full size 12/8/03 6:59 PM Page 1
Roll Calipers
Series 310
The Roll Caliper, as its name implies, is a special gage to measure
rolled or turned products, such as: metal sheets; textile; rubber or
paper rolls; large and cylindrical workpieces; extruded tubes; welded
tubes; etc.
The Roll Caliper is supplied without Gage Head. Select MITUTOYO
Dial Indicator or Mu-Checker with Cartridge Head and order together
with the Roll Caliper.
Digi-Derm
Series 179
Digi-Derm is a non-destructive, electronic coating thick-
ness gage. Readings are displayed on the clear LCD
screen and can be sent to any Mitutoyo SPC system for
179-746
data analysis. Digi-Derm is battery powered for portable
use and can also operate on AC power with an optional
adaptor.
Specifications
Digi-Derm
Inch/Metric
Measuring LCD
Order No. Range Resolution Accuracy Remarks
±.00008" ±1 digit (Range: 0–.0039")
0–.059" .00005" Non-magnetic coating on
179-746 ±2% ±1 digit (Range: .004"–.043")
(0–1.5mm) (0.001mm) magnetic material
±3% ±1 digit (Range: .043"–.06")
0–.039" .00005" ±.00008" ±1 digit (Range: 0–.0039") Non-conductive coating on
179-756
(0–1.0mm) (0.001mm) ±2% ±1 digit (Range: .0039"–.043") non-magnetic material
For SPC output order connecting cable 936937 (1m) or 965014 (2m).
Replacement Part (Calibration Film for 179 series) Replacement Part (Base metal)
Film 527599 527600 527601 527602 527603 527604 685013 527605 Can be used for
Order No. Set No. (25µm) (50µm) (100µm) (250µm) (500µm) (1000µm) (1500µm) (2000µm) Order No. coating thickness gages
179-710 937287 ● ● 179-710
179-711 937288 ● ● ● ● ● 179-711
933038
179-731-1 937288 ● ● ● ● ● 179-712
179-712 937289 ● ● ● ● ● 179-746
179-746 945014 ● ● ● ● ● ● ● 179-731-1
937305
179-756 945049 ● ● ● ● ● ● 179-756
S-36
S-37 (2003) full size 12/8/03 7:01 PM Page 1
BENCH COMPARATOR
Bench Comparator
Series162
Features
• Overall range 0–100mm, for OD measurements.
• Variable anvil pressures.
• Dial Indicator is shockproof.
• Adjustable work-table size: 1-9/16 x 2-3/4".
Vertical adjustment: 1-9/16".
• MITUTOYO Gage Blocks are furnished with the
Bench Comparator.
Inch type: 1", 2"
Metric type: 25mm, 50mm
• Supplied with case.
• Weight: 33 lbs. Mu-Checker: 519-402A
Cartridge Head: 519-332, 334
Bench Comparator: 162-102
Specifications
Inch/Metric
Overall Micrometer Micrometer Dial Indicator Accuracy Variable Attachment
Order No. Range Head Range Head Grad. Grad. Micro-Head Indicator Pressure Diameter
162-101 0–100mm 0–25mm 0.001mm 0.001mm (0-50-0) ±2µm 200, 400, 100 gf ø8mm
within 1/3
graduations 0.5, 1, 1.5, 2, ø3/8"
162-102 0–4" 0–1" .0001" .0001" (0-5-0) ±.0001"
2.5, 3 lbs.
Specifications
Workpiece Capacity Parallelism Flatness Attachment
Order No. Center-to-Center Diameter Max. Weight of Centers of Surface Diameter
967-101 13.7" 7" 88 lbs. .0002" .0003" Ø3/8"
967-203 5.9" 3.8" 17.5 lbs. .0002" .0004" Ø3/8"
967-201 11.8" 5.8" 35 lbs. .0002" .0006" Ø3/8"
967-204 17.7" 7.8" 44 lbs. .0002" .0007" Ø3/8"
967-202 23.6" 9.8" 66 lbs. .00024" .0008" Ø3/8"
Optional Accessories
069303 Special attachment for mounting 967-201 in vertical position
069304 Special attachment for mounting 967-203 in vertical position
S-37
S-38 (2003) full size 12/8/03 7:03 PM Page 1
HAND TACHOMETERS
982-551 982-552
Specifications
Order No. 982-551 982-552
Revolution per minute 1.0 – 25,000 rpm –
Rotation speed – Non-contact: 6.0 – 99,999 rpm;
Contact: 6.0 – 25,000 rpm
Measuring accuracy
Revolution 1.0 – 599.9rpm: ±1rpm, 600.0 – 25,000 rpm: 6.0 – 599.9 rpm: ±1rpm, 600.0 – 99,999 rpm
±0.006% and ±0.5 digit ±0.006% and ±0.5 digit
Surface, Speed, Length ±0.4% and 1 digit ±0.4% and ±1 digit
Detection Optical coupler, 20 pulses per revolution Laser diode
Outside dimensions 4.83" L x 2.52" W x 1.24" H 4.55" L x 2.52" W x 1.24" H
(1.22.5mm x 64mm x 31.5mm) Overall length with contact adapter: 149mm
Weight 0.37 lbs. with batteries (170 g) Main unit: 0.35 lbs. with batteries (160 g)
contact adapter: 0.11 lbs. (50 g)
Specifications
Optional Accessories
For Digital Hand Tachometers, SERIES 982
Order No. Description Dimension Drawing
010049 Cone Adapter, Standard D = 1/2"
010050 Cone Adapter, 5/8" D = 5/8"
010051 Cone Adapter, 3/4" D = 3/4"
D = 11/4"
010052 Cone Adapter, 11/4"
d = 1/2"
010053 Funnel Adapter, Standard D = 1/2"
S-38
S-39 (2003) full size 12/8/03 7:06 PM Page 1
TORQUE WRENCHES
Datatorq
Series 983 – Digital Torque Wrenches with SPC output
983-213
983-210
Features
• Programmable torque tolerance • Memory for up to 4000 torque Accuracy
(high/low limits) data ±1% from 20-100% of range
• Peak Hold mode • Batteries: ±1%, Plus 5 increments, from
• Track mode A 9V alkaline battery 10-20% of range
Battery life 60 hours of operation
• Red and Green Go/No Go lights A "Lo Bat" indication on display • A Certificate of Accuracy, trace-
• Analog auto scaling bar-graph signals for replacement. able to the NIST, is furnished with
display each Datatorq.
• All calibration data is stored in the
• Audible buzzer microprocessor.
Specifications
Datatorq
Order No. Range Increments Drive Length Mass
5-50 in.lb .01 in. lb.
5.6-56 dNm .01 dNm 1/4"
983-210 13.5" 1.5 lb
5.7-57 cmkg .01cmkg
80-800 in. oz. .1 in. oz.
25-250 in. lb .1 in. lb.
983-211 28-282 dNm .1 dNm 3/8" 14.9" 2.0 lb.
29-288 cmkg .1 cmkg
5-50 ft. lb. .01 ft. lb.
68-677 dNm .1 dNm 3/8"
983-212 14.9" 2.0 lb.
69-691 cmkg .1 cmkg
60-600 in. lb. .1 in. lb.
25-250 ft. lb. .1 ft. lb.
983-213 34-338 Nm .1 Nm 1/2" 21.5" 3.2 lb.
3.4-34 mkg .01 mkg
60-600 ft. lb. .1ft. lb.
983-214 81-813 Nm .1 Nm 3/4" 46.5" 9.5 lb.
8.3-83 mkg .01 mkg
100-1000 ft. lb. 1 ft. lb.
983-215 135-1355 Nm 1 Nm 1" 74.0" 19.0 lb.
14-138 mkg 1 mkg
Optional Accessories: SPC cable No. 50AAA620
S-39
S-40 (2003) full size 12/8/03 6:46 PM Page 1
ACCESSORIES
Ball Attachment
101468 .200" DIA. hardened steel ball
101469 .250" DIA. Micrometer Anvil to
measure concave surface or cylindrical
wall thickness.
Tie Clips
NOTE: See additional information on 101420 Micrometer (gold-color)
micrometer anvil attachments at the 10142001 Dial Caliper (silver-color)
end of the micrometer section in this 10142002 Digimatic Micrometer (silver-color)
catalog. 10142003 Dial Indicator (silver-color)
10142004 Digimatic Caliper
(silver-color)
10142005 CMM (silver-color)
10142006 Digimatic Indicator (silver-color)
PRICE LIST —
For Replacement Parts and Accessories 10
11
S-40
T-01 (2003) full size 12/12/03 4:10 PM Page 1
Gage Blocks
Gage Block - Series 516 T-2
GAGE BLOCKS
Gage Block
Series 516
Mitutoyo offers a complete selection of gage blocks
available in a choice of rectangular or square, metric or
inch and steel or CERA (ceramic) types. Mitutoyo CERA
Blocks are some of the finest gage blocks available any-
where in the world.
Features
CERA Blocks
• Corrosion-resistant: The CERA Block is made from zir-
conium-based ceramic which will not corrode unless
subjected to the most corrosive chemicals. Anti-corro-
sion treatment is not required when handled normally
(i.e. with fingers), resulting in simple maintenance and
storage.
• Abrasion resistant: CERA Blocks have 10 times the
abrasion resistance of steel gage blocks.
T-2
T-03 (2003) full size 12/11/03 11:22 AM Page 1
GAGE BLOCKS
Gage Blocks Rectangular Block
Certificate and Serial Number Gage Size Face Width (A) Face Depth (B)
Up to .2" 1.181" .355"
It is an absolute necessity that each gage block car- Over .2" up to 40" .355"1.378"
ries its own Serial Number for calibration purposes, Up to 10mm 9mm 30mm
Over 10mm up to 1000mm 9mm 35mm L=Gage Length
and, to determine the actual size to the closest mil-
lionth of an inch. Please note all MITUTOYO Blocks Square Block
are serialized regardless of the grade classification. Gage Size Face Width (C) Face Depth (D)
Inch (up to 40") .95" .95"
A Certificate of Accuracy, traceable to the NIST, is Metric (up to 1000mm) 24.1mm 24.1mm
furnished with each MITUTOYO gage block set and
individual block.
ASME (American Society of Mechanical Engineers) Deviations and Tolerance on Length for Metric and Inch Gage Blocks
Calibration Grade K Grade 00 Grade 0 Grade AS-1 Grade AS-2
Limit Limit Limit Limit Limit
Deviations Deviations Deviations Deviations Deviations
of Length of Length of Length of Length of Length
at any Tolerance at any Tolerance at any Tolerance at any Tolerance at any Tolerance
Nominal Point From for the Point From for the Point From for the Point From for the Point From for the
Length Range Nominal Variation In Nominal Variation In Nominal Variation In Nominal Variation In Nominal Variation In
Length Length Length Length Length Length Length Length Length Length
In in mm ± te µm tv µm ± te µm tv µm ± te µm tv µm ± te µm tv µm ± te µm tv µm
l n ≤ 0.5 0.30 0.05 0.10 0.05 0.14 0.10 0.30 0.16 0.60 0.30
0.5 < l n ≤ 10 0.20 0.05 0.07 0.05 0.12 0.10 0.20 0.16 0.45 0.30
10 < l n ≤ 25 0.30 0.05 0.07 0.05 0.14 0.10 0.30 0.16 0.60 0.30
25 < l n ≤ 50 0.40 0.06 0.10 0.06 0.20 0.10 0.40 0.18 0.80 0.30
50 < l n ≤ 75 0.50 0.06 0.12 0.07 0.25 0.12 0.50 0.18 1.00 0.35
75 < l n ≤ 100 0.60 0.07 0.15 0.07 0.30 0.12 0.60 0.20 1.20 0.35
100 < l n ≤ 150 0.80 0.08 0.20 0.08 0.40 0.14 0.80 0.20 1.60 0.40
150 < l n ≤ 200 1.00 0.09 0.25 0.09 0.50 0.16 1.00 0.25 2.00 0.40
200 < l n ≤ 250 1.20 0.10 0.30 0.10 0.60 0.16 1.20 0.25 2.40 0.45
250 < l n ≤ 300 1.40 0.10 0.35 0.10 0.70 0.18 1.40 0.25 2.80 0.50
300 < l n ≤ 400 1.80 0.12 0.45 0.12 0.90 0.20 1.60 0.30 3.60 0.50
400 < l n ≤ 500 2.20 0.14 0.50 0.14 1.10 0.25 2.20 0.35 4.40 0.60
500 < l n ≤ 600 2.60 0.16 0.65 0.16 1.30 0.25 2.60 0.40 5.00 0.70
600 < l n ≤ 700 3.00 0.18 0.75 0.18 1.50 0.30 3.00 0.45 6.00 0.70
700 < l n ≤ 800 3.40 0.20 0.85 0.20 1.70 0.30 3.40 0.50 6.50 0.80
800 < l n ≤ 900 3.80 0.20 0.95 0.20 1.90 0.35 3.80 0.50 7.50 0.90
900 < l n ≤ 1000 4.20 0.25 1.00 0.25 2.00 0.40 4.20 0.60 8.00 1.00
T-3
T-04 (2003) full size 12/11/03 11:21 AM Page 1
GAGE BLOCKS
516-302-26
516-902-26 81 Piece CERA/Steel Combo set with 2",
81 pcs. Grade 2 Set 3", & 4" steel blocks.
CERA Block
Steel Block
Inch
Order No.
Blocks Per Set Blocks Included in Set Grade Steel CERA
K 516-549-56 516-557-56
9 pc. .1001–.1009" Step of .0001"
00 516-901-26 516-301-26
49 pcs. .101–.149" Step of .001"
81 0 516-902-26 516-302-26
19 pcs. .05–.95" Step of .05"
AS-1 516-903-26 516-303-26
4 pcs. 1–4" Step of 1"
AS-2 516-904-26 516-304-26
1 pc. .10005" K 516-550-56 516-558-56
9 pcs. .1001–.1009" Step of .0001" 00 516-913-26 516-313-26
35 9 pcs. .101–.109" Step of .001" 0 516-914-26 516-314-26
10 pcs. .10–.19" Step of .01" AS-1 516-915-26 516-315-26
6 pcs. .20, .30, .50, 1.0, 2.0, and 4.0" AS-2 516-916-26 516-316-26
K 516-551-56 —
1 pcs. .02005"
00 516-917-26 —
9 pcs. .0201–.0209" Step of .0001"
28 0 516-918-26 —
9 pcs. .021–.029" Step of .001"
AS-1 516-919-26 —
9 pcs. .010–.090" Step of .010"
AS-2 516-920-26 —
T-4
T-05 (2003) full size 12/11/03 11:21 AM Page 1
GAGE BLOCKS
516-926-26
10 Pc.
Grade 2 Set
516-322-26
10 Pc.
Cera Type
Thin Block Set: Steel
Blocks per set Blocks included in set Grade Order No.
0 516-926-26
10 .005-.050" Step of .005"
AS-1 516-927-26
Long Block Set: Steel, Cera
Order No.
Blocks per set Blocks included in set Grade Steel CERA
1, 2, 3, 4, 5, 6, 7, 8" 0 516-126-26
8 0 516-712-26 516-742-26
5, 6, 7, 8, 10, 12, 16, 20"
AS-1 516-713-26 516-743-26
Set for Micrometer Inspection: Steel, CERA
Order No.
Blocks per set Blocks included in set Grade Steel CERA
K 516-554-56 516-561-56
.0625, .100, .125, .200,
00 516-929-26 516-333-26
.250, .300, .500, 1, 2"
9 0 516-930-26 516-334-26
1 pc. Optical parallel
AS-1 516-931-26 516-335-26
K — 516-563-26
.0625, .100, .125, .200,
00 — 516-329-26
.0625, .100, .125, .200,
9 0 516-934-26 516-330-26
.250, .300, .500, 1, 2"
AS-1 516-935-26 516-331-26
.105, .210, .315, .420, 00 516-921-26 516-321-26
10 .500, .605, .710, .815" 0 516-922-26 516-322-26
1 pc. Optical parallel AS-1 516-923-26 516-323-26
Wear Block Sets: Tungsten Carbide, CERA
Order No.
Blocks per set Size Grade Carbide CERA
0 516-809-26 516-836-26
2 pcs. .05"
AS-1 516-808-26 516-837-26
2
0 516-805-26 516-834-26
2 pcs. .10"
AS-1 516-804-26 516-835-26
T-5
T-06 (2003) full size 12/11/03 11:20 AM Page 1
GAGE BLOCKS
INDIVIDUAL
NOTE: To select the grade of Individual
Gage Blocks add the following suffixes
to the block's order no.
Grade K 00 0 AS-1 AS-2
-516 -521 -531 -541 -551
Example: 611105-516
.050" Gage Block in Grade K
Size 5"~20"
T-6
T-07 (2003) full size 12/8/03 10:58 PM Page 1
GAGE BLOCKS
5.0 611205
6.0 611206
7.0 611207
8.0 611208
10.0 611222
12.0 611223
16.0 611224
20.0 611225
Size .45"~4"
T-7
T-08 (2003) full size 12/11/03 11:20 AM Page 1
GAGE BLOCKS
516-519-26
88 pcs.
Grade 2 Set
Metric
1mm Base Sets
Order No.
Blocks per Set Blocks Included in Set Grade Steel CERA
1 pc. 1.0005mm K 516-531-56 516-541-56
9 pcs. 1.001–1.009mm Step of 0.001mm 00 516-937-26 516-337-26
112 49 pcs. 1.01–1.49mm Step of 0.01mm 0 516-938-26 516-338-26
49 pcs. 0.5–24.5mm Step of 0.5mm AS-1 516-939-26 516-339-26
4 pcs. 25–100mm Step of 25mm AS-2 516-940-26 516-340-26
K 516-533-56 516-542-56
1 pc. 1.005mm 00 516-941-26 516-341-26
103 49 pcs. 1.01–1.49mm Step of 0.01mm 0 516-942-26 516-342-26
49 pcs. 0.5–24.5mm Step of 0.5mm AS-1 516-943-26 516-343-26
4 pcs. 25–100mm Step of 25mm AS-2 516-944-26 516-344-26
K 516-535-56 516-543-56
9 pcs. 1.001–1.009mm Step of 0.001mm 00 516-945-26 516-345-26
87 49 pcs. 1.01–1.49mm Step of 0.01mm 0 516-946-26 516-346-26
19 pcs. 0.5–9.5mm Step of 0.5mm AS-1 516-947-26 516-347-26
10 pcs. 10–100mm Step of 10mm AS-2 516-948-26 516-348-26
1 pc. 0.5mm K 516-536-56 516-544-56
9 pcs. 1.001–1.009mm Step of 0.001mm 00 516-953-26 516-353-26
56 9 pcs. 1.01–1.09mm Step of 0.01mm
9 pcs. 1.1–1.9mm Step of 0.1mm 0 516-954-26 516-354-26
24 pcs. 1–24mm Step of 1mm AS-1 516-955-26 516-355-26
4 pcs. 25–100mm Step of 25mm AS-2 516-956-26 516-356-26
1 pc. 1.005mm K 516-537-56 516-545-56
9 pcs. 1.01–1.09mm Step of 0.01mm 00 516-957-26 516-357-26
47 9 pcs. 1–1.9mm Step of 0.1mm 0 516-958-26 516-358-26
24 pcs. 1–24mm Step of 1mm AS-1 516-959-26 516-359-26
4 pcs. 25–100mm Step of 25mm AS-2 516-960-26 516-360-26
T-8
T-09 (2003) full size 12/11/03 11:19 AM Page 1
GAGE BLOCKS
516-703-26
8 pcs. Long Block Set 516-831-26
Wear Block Set CERA Block
T-9
T-10 (2003) full size 12/11/03 11:19 AM Page 1
GAGE BLOCKS
Individual
Size 0.5mm~5.5mm
Size (mm) Steel CERA Size (mm) Steel CERA Size (mm) Steel CERA
0.10 611821 0.46 611888 0.82 611923
0.11 611860 0.47 611889 0.83 611924
0.12 611861 0.48 611890 0.84 611925
0.13 611862 0.49 611891 0.85 611926
0.14 611863 0.50 611506 613506 0.86 611927
0.15 611822 0.51 611892 0.87 611928
0.16 611864 0.52 611893 0.88 611929
0.17 611865 0.53 611894 0.89 611930
0.18 611866 0.54 611895 0.90 611931
0.19 611867 0.55 611896 0.91 611932
0.20 611823 0.56 611897 0.92 611933
0.21 611868 0.57 611898 0.93 611934
0.22 611869 0.58 611899 0.94 611935
0.23 611870 0.59 611900 0.95 611936
0.24 611871 0.60 611901 0.96 611937
0.25 611824 0.61 611902 0.97 611938
0.26 611872 0.62 611903 0.98 611939
0.27 611873 0.63 611904 0.99 611940
0.28 611874 0.64 611905 0.991 611551 613551
0.29 611875 0.65 611906 0.992 611552 613552
0.30 611825 0.66 611907 0.993 611553 613553
0.31 611876 0.67 611908 0.994 611554 613554
0.32 611877 0.68 611909 0.995 611555 613555
0.33 611878 0.69 611910 0.996 611556 613556
0.34 611879 0.70 611911 0.997 611557 613557
0.35 611826 0.71 611912 0.998 611558 613558
0.36 611880 0.72 611913 0.999 611559 613559
0.37 611881 0.73 611914 1.0 611611 613611
0.38 611882 0.74 611915 1.0005 611520 613520
0.39 611883 0.75 611916 1.001 611521 613521
0.40 611827 0.76 611917 1.002 611522 613522
0.41 611884 0.77 611918 1.003 611523 613523
0.42 611885 0.78 611919 1.004 611524 613524
0.43 611886 0.79 611920 1.005 611525 613525
0.44 611887 0.80 611921 1.006 611526 613526
0.45 611828 0.81 611922 1.007 611527 613527
T-10
T-11 (2003) full size 12/8/03 11:01 PM Page 1
GAGE BLOCKS
T-11
T-12 (2003) full size 12/11/03 11:18 AM Page 1
GAGE BLOCKS
Size 10.3mm~100mm
Size 125mm~1000mm
Size (mm) Steel CERA Size (mm) Steel CERA Individual Wear Gage Blocks
10.3 611852 613852 25.25 611754 613754 Size (mm) Carbide CERA
10.5 611650 613650 30 611673 613673 1 612611 613611
11.0 611621 613621 35 611755 613755 2 612612 613612
11.5 611651 613651 40 611674 613674
12.0 611622 613622 45 611756 613756
12.5 611652 613652 50 611675 613675 SPECIAL SIZE ORDER
12.9 611853 613852 60 611676 613676 Any size from
13.0 611623 613623 70 611677 613677 0.10mm Thru 1000mm.
13.5 611653 613653 75 611801 613801 (CERA Block is 0.50mm thru
14.0 611624 613624 80 611678 613678 500mm)
14.5 611654 613654 90 611679 613679 SPECIFY:
15.0 611625 613625 100 611681 613681
• Size
15.5 611655 613655 125 611802 613802
16.0 611626 613626 150 611803 613803 • Steel or CERA
16.5 611656 613656 175 611804 613804 • Grade
17.0 611627 613627 200 611682 613682
17.5 611657 613657 250 611805 613805
17.6 611854 613854 300 611683 613683
18.0 611628 613628 400 611684 613684
18.5 611658 613658 500 611685 613685
19.0 611629 613629 600 611840
19.5 611659 613659 700 611841
20.0 611672 613672 750 611842
20.2 611855 613855 800 611843
20.5 611660 613660 900 611844
21.0 611631 613631 1000 611845
21.5 611661 613661
22.0 611632 613632
22.5 611662 613662
22.8 611856 613856 NOTE: To select the grade of Individual Gage Blocks
23.0 611633 613633 add the following suffixes to the block's order no.
23.5 611663 613663 Grade K 00 0 AS-1 AS-2
24.0 611634 613634 -516 -521 -531 -541 -551
24.5 611664 613664 Example: 611635-516 0.25mm Gage Block in Grade K
25.0 611635 613635
T-12
T-13 (2003) full size 12/8/03 11:02 PM Page 1
GAGE BLOCKS
516-604
To expand the variety of Rectangular Gage Block applications, Mitutoyo offers the Gage Block Accessories Set. By
assembling the items in the set, your Gage Blocks are easily and quickly changed into a precision measuring system.
Specifications
Assortment of Accessories
Inch Set Order No. Metric Set Order No. Accessory (s)
Part No. Accessories 516-603 516-604 516-601 516-602 included in a set
619102 Holder 2.24" • 1 pc.
619103 Holder 4" • • 1 pc.
619104 Holder 6" • • 1 pc.
619105 Holder 10" • • 1 pc
619002 Holder 60mm • 1 pc
619003 Holder 100mm • • 1 pc.
619004 Holder 160mm • • 1 pc.
619005 Holder 250mm • • 1 pc.
619109 Holder Base 1.375" • • 1 pc.
619009 Holder Base 35mm • • 1 pc.
619110 Half round jaw .100" • • 2 pcs.
619010 Half round jaw 2mm • • 2 pcs.
619111 Half round jaw .200" • • 2 pcs.
619011 Half round jaw 5mm • • 2 pcs.
619112 Half round jaw .250" • • 2 pcs.
619012 Half round jaw 8mm • • 2 pcs.
619113 Half round jaw .500" • 2 pcs.
619013 Half round jaw 12mm • 2 pcs.
619114 Half round jaw .750" • 2 pcs.
619014 Half round jaw 20mm • 2 pcs.
619118 Plain jaw 6" • 2 pcs.
619018 Plain jaw 160mm • 2 pcs.
619019 Scriber point • • • • 1 pc.
619020 Center point • • • • 1 pc.
619021 Tram point • • 2 pcs.
619122 Triangular straightness edge 4" • • 1 pc.
619022 Triangular straightness edge 100mm • • 1 pc.
619123 Triangular straight edge 6" • 1 pc.
619023 Triangular straight edge 160mm • 1 pc.
Total Qty. in set 14 pcs. 22 pcs. 22 pcs. 14 pcs.
T-13
T-14 (2003) full size 12/8/03 11:04 PM Page 1
GAGE BLOCKS
Holder Type II
Type I
Specifications
Order No. L1 L2 B B1 B2 Type
619102 4.65~7.01" 4.13" .59~2.40" — — I
619002 118~178mm 105mm 15~61mm — — I
619103 6.89~10.94" 5.91" .16~4.17" — — I
619003 175~278mm 150mm 4~106mm — — I
619104 9.21~13.27" 8.27" 2.44~6.50" .39~4.45" — II
619004 234~337mm 210mm 62~165mm 10~113mm — II
619105 12.80~16.85" 11.81" 6.02~10.08" .43~4.53" 236~6.42" II
619005 325~428mm 300mm 153~256mm 11~115mm 60~163mm II
Unit: (mm)
T-14
T-15 (2003) full size 12/8/03 11:04 PM Page 1
GAGE BLOCKS
Holder base
L1
A
Order No. L L1 A
619022 100mm 160mm 16mm
Order No. A 619023 160mm 220mm 20mm
619009 35 ± 0.005mm 619122 4" 6.36" .63"
619109 1.375" ± .0002" 619123 6" 8.36" .79"
Order No. L
619018 160mm
619118 6"
T-15
T-16 (2003) full size 12/8/03 11:05 PM Page 1
GAGE BLOCKS
Holder B and C
Holder E No. 619035
• For coupling two long gage blocks together with
other gage blocks up to 1.4" (35mm) (holder C: 5.6" • For attaching to the holder base together with other
(140mm). gage blocks up to 125mm or 5"
• For attaching the jaws with two adaptors. • For attaching a jaw with one adaptor.
l = 1.77~6.10" (45~155)
Order No. l L
619032 Holder B 3.2" (80mm) max. 4.96" (126mm)
619033 Holder C 7.6" (190mm) max. 9.29" (236mm)
T-16
T-17 (2003) full size 12/11/03 11:18 AM Page 1
GAGE BLOCKS
516-424-26 516-222-26
36 pcs. Grade 3 Set 36 pcs. Grade 2 Set
Inch
Order No.
Blocks per Set Blocks Included in Set Grade Steel CERA
1 pc. .050" 00 516-401-26 516-201-26
10 pcs. .1000–.1009" Step of .0001"
0 516-402-26 516-202-26
81 49 pcs. .101–.149" Step of .001"
17 pcs. .15–.95" Step of .05" AS-1 516-403-26 516-203-26
4 pcs. 1–4" Step of 1" AS-2 516-404-26 516-204-26
1 pc. .050"
00 516-421-26 516-221-26
10 pcs. .1000–.1009" Step of .0001"
9 pcs. .101–.109" Step of .001" 0 516-422-26 516-222-26
36
9 pcs. .11–.19" Step of .01" AS-1 516-423-26 516-223-26
4 pcs. .2–.5" Step of .1"
3 pcs. 1, 2, and 4" AS-2 516-424-26 516-224-26
1 pc. .02005" 00 516-417-26 —
9 pcs. .0201–.0209" Step of .0001" 0 516-418-26 —
28
9 pcs. .021–.029" Step of .001" AS-1 516-419-26 —
9 pcs. .010–.090" Step of .01" AS-2 516-420-26 —
Long Block Set
Order No.
Blocks per Set Blocks Included in Set Grade Steel CERA
0 516-762-26 —
8 5, 6, 7, 8, 10, 12, 16, 20"
AS-1 516-763-26 —
Wear Block Set: Tungsten Carbide, Ceramic
Order No.
Blocks per Set Size Grade Carbide CERA
0 516-824-26 516-846-26
2 2 pcs. .05"
AS-1 516-825-26 516-847-26
0 516-826-26 516-844-26
2 2 pcs. .10"
AS-1 516-827-26 516-845-26
T-17
T-18 (2003) full size 12/11/03 11:17 AM Page 1
GAGE BLOCKS
T-18
T-19 (2003) full size 12/8/03 11:07 PM Page 1
GAGE BLOCKS
Size (Inch) Steel CERA Size (Inch) Steel CERA SPECIAL SIZE ORDER
.146 614186 616186 5.0 614205 Any size from .01" thru 20" (CERA
.147 614187 616187 6.0 614206 Block is .05" thru 4").
.148 614188 616188 7.0 614207 Specify:
.149 614189 616189 8.0 614208 • Size
.15 614115 616115 10 614222
• Steel or CERA
.16 614116 616116 12 614223
• Grade
.17 614117 616117 16 614224
.18 614118 616118 20 614225
.19 614119 616119
.20 614192 616192
.25 614212 616212 Individual Wear Gage Blocks
.30 614193 616193 Size (Inch) Carbide
.35 614213 616213 .050 615105
.375 (3/8) 614309 .100 615191
.40 614194 616194
.45 614214 616214
.50 614195 616195
.55 614215 616215
.60 614196 616196
.65 614216 616216
.70 614197 616197
.75 614217 616217
.80 614198 616198
.85 614218 616218
.90 614199 616199
.95 614219 616219
1.0 614201 616201
2.0 614202 616202
3.0 614203 616203 Nominal size .500"~4"
4.0 614204 616204
IN
5
T-19
T-20 (2003) full size 12/11/03 11:17 AM Page 1
GAGE BLOCKS
Specifications
Square Gage Block Sets
Metric
Order No.
Blocks per Set Blocks Included in Set Grade Steel
1 pc. 1.0005mm
00 516-437-26
9 pcs. 1.001–1.009mm Step of 0.001mm
112 49 pcs. 1.01–1.49mm Step of 0.01mm 0 516-438-26
49 pcs. 0.5–24.5mm Step of 0.5mm
4 pcs. 25–100mm Step of 25mm AS-1 516-439-26
1 pc. 1.005mm
00 516-449-26
49 pcs. 1.01–1.49mm Step of 0.01mm
76 19 pcs. 0.5–9.5mm Step of 0.5mm 0 516-450-26
4 pcs. 10–40mm Step of 10mm
3 pcs. 25–100mm Step of 25mm AS-1 516-451-26
1 pc. 1.005mm
00 516-457-26
9 pcs. 1.01–1.09mm Step of 0.01mm
47 9 pcs. 1.1–1.9mm Step of 0.1mm 0 516-458-26
24 pcs. 1–24mm Step of 1mm
4 pcs. 25–100mm Step of 25mm AS-1 516-459-26
T-20
T-21 (2003) full size 12/11/03 11:16 AM Page 1
GAGE BLOCKS
Individual
Metric
Size (mm) Steel
0.500 614506
1.000 614611 3.0
1.0005 614520
1.001 614521
1.002 614522
1.003 614523
1.004 614524
1.005 614525 Nominal size 4~12mm
1.006 614526
1.007 614527
1.008 614528
1.009 614529
1.01 614561
1.02 614562 Size (mm) Steel Size (mm) Steel
1.03 614563 1.26 614586 1.49 614609
1.04 614564 1.27 614587 1.50 614641
1.05 614565 1.28 614588 1.60 614516
1.06 614566 1.29 614589 1.7 614517
1.07 614567 1.30 614590 1.8 614518
1.08 614568 1.31 614591 1.9 614519
1.09 614569 1.32 614592 2.0 614612
1.10 614570 1.33 614593 2.5 614642
1.11 614571 1.34 614594 3.0 614613
1.12 614572 1.35 614595 3.5 614643
1.13 614573 1.36 614596 4.0 614614
1.14 614574 1.37 614597 4.5 614644
1.15 614575 1.38 613498 5.0 614615
1.16 614576 1.39 614599 5.5 614645
1.17 614577 1.40 614600 6.0 614616
1.18 614578 1.41 614601 6.5 614646
1.19 614579 1.42 614602 7.0 614617
1.20 614580 1.43 614603 7.5 614647
1.21 614581 1.44 614604 8.0 614618
1.22 614582 1.45 614605 8.5 614648
1.23 614583 1.46 614606 9.0 614619
1.24 614584 1.47 614607 9.5 614649
1.25 614585 1.48 614608 10.0 614671
T-21
T-22 (2003) full size 12/8/03 11:11 PM Page 1
GAGE BLOCKS
T-22
T-23 (2003) full size 12/8/03 11:14 PM Page 1
GAGE BLOCKS
Center point
Part No. H
619053 .100" ± .0003"
619073 2 ± 0.01mm
Scriber point
Part No. 619054
Plain jaw
Part No. H
619052 .5" ± 50µinch
619072 10 ± 0.001mm
Flat head screw L
Part No. L
619057 1.24" (31.6mm)
619058 .62" (15.8mm)
T-23
T-24 (2003) full size 12/16/03 10:44 AM Page 1
GAGE BLOCKS
Tie rod
Order No. L
619065 .75" (19)
619064 1.50" (38)
619063 2.24" (57)
619062 2.99" (76)
Unit: (mm)
T-24
T-25 (2003) full size 12/8/03 11:16 PM Page 1
GAGE BLOCKS
Ceraston 601644
Features
• Alumina-ceramic grinding stone for removing burrs
from hard materials such as ceramics that ordinary
grinding stones cannot handle.
• Can be used both for steel gage blocks and
CERA Blocks.
601645
(1) Wipe any dust and oil films from the gage block and
the Arkansas stone (Ceraston) using a solvent.
(2) Place the gage block on the Arkansas stone
(Ceraston) so that the measuring face that has burrs
is on the abrasive surface of the stone. While apply-
ing light pressure, move the gage block back and
forth about ten times (Fig. 1). Use a block rubber for
thin gage blocks to apply even pressure (Fig. 2).
(3) Check the measuring face for burrs with an optical
flat. If the burrs have not been removed, repeat step
(2). If burrs are too large, they may not be removed
with a grinding stone. If so, discard the gage block.
Note: The abrasive surface of an Arkansas stone
(Ceraston) must be made flat by lapping it from time to
time. After lapping the Arkansas stone (Ceraston), the Removing burrs
lapping powder must be completely removed from the
surface to prevent the surface of the gage block from Fig. 1 Fig. 2
being scratched.
Specifications
Order No. Dimensions
601644 6"(W) x 2"(D) x .8"(H)
601645 4"(W) x 1"(D) x .48"(H)
Maintenance Kit
for Gage Blocks
Series 516
Features
• Includes all necessary maintenance tools for daily care
and storage of gage blocks.
516-650
• Supplied in a fitted wooden case for portable use.
Specifications
Order No. 516-650
600001 Anti-corrosive oil
601645 Ceraston
600003 Optical flat
Set 600004 Tweezers
configuration 600005 Blower brush
600006 Cleaning paper
600007 Artificial leather mat
600008 Reagent bottle
600009 Gloves
T-25
T-26 (2003) full size 12/8/03 11:17 PM Page 1
GAGE BLOCKS
Optical Parallels
Series 157
Set Individual
Order No. Order No. Size
157-901 157-109 .5000"
157-110 .5062"
157-111 .5125"
157-112 .5187"
T-26
U-01 (2003) full size 12/11/03 3:42 PM Page 1
Granite Products
Black Granite Surface Plates - Series 517 U-2, U-3
Steel Stands for Black Granite Surface Plates U-4
Accessories for Black Surface Plates - Series 517 U-5
U-02 (2003) full size 12/8/03 9:23 AM Page 1
GRANITE PRODUCTS
Features
• Natural granite seasoned for thousands of years is free • All plates from 48"x108" and larger are Machine Base
from deterioration or dimensional change over time. Gray Granite. Smaller plates are Black Granite.
• Granite surface plate has many advantages over cast • Surface Plates, to size of specifications other than
iron surface plates: standard, available on special order.
Twice as hard as cast iron. • Surface Plates, with the bolt screws, available on spe-
Minimal changes in dimension due to temperature cial order.
changes.
• All MITUTOYO Surface Plates shipped F.O.B.
Free from wringing, so there is no interruption of work.
Escondido, California.
Free from burrs or protrusions because of the fine
grain structure and insignificant stickiness; this ensures
a high degree of flatness over a long service life and
causes no damage to other parts or instruments.
• Trouble-free operation for use with magnetic materials.
• Long life and rust-free, resulting in low maintenance ZE
costs. SI
U-2
U-03 (2003) full size 12/8/03 9:23 AM Page 1
GRANITE PRODUCTS
Specifications
Black Granite Surface Plates
Inch
100 lbs.-Load/sq. ft., no ledge.
AA Laboratory Grade A Inspection Grade B Shop Grade
Size H Acc. Order No. Wt. H Acc. Order No. Wt. H Acc. Order No. Wt.
8 x 12" 3" 50 517-700 30 2" 100 517-800 25 2" 200 517-900 25
9 x 12" 3" 50 517-701 40 3" 100 517-801 40 2" 200 517-901 30
12 x 12" 3" 50 517-702 50 3" 100 517-802 50 3" 200 517-902 50
12 x 18" 4" 50 517-703 100 4" 100 517-803 100 4" 200 517-903 100
18 x 18" 4" 50 517-704 150 4" 100 517-804 150 3" 200 517-904 100
18 x 24" 4" 65 517-705 200 4" 130 517-805 200 4" 260 517-905 200
24 x 24" 5" 70 517-706 310 4" 140 517-806 259 3" 280 517-906 200
24 x 30" 5" 75 517-707 400 5" 150 517-807 400 4" 300 517-907 300
24 x 36" 6" 85 517-708 600 5" 170 517-808 500 4" 340 517-908 400
24 x 48" 8" 150 517-709 1000 6" 300 517-809 800 5" 600 517-909 650
30 x 36" 6" 100 517-710 800 5" 200 517-810 600 5" 400 517-910 600
30 x 48" 8" 150 517-711 1300 6" 300 517-811 1000 6" 600 517-911 1000
30 x 60" 12" 200 517-712 1900 10" 500 517-812 1535 8" 1000 517-912 1150
36 x 36" 6" 100 517-713 900 5" 200 517-813 780 5" 400 517-913 700
36 x 48" 8" 150 517-714 1500 6" 300 517-814 1200 6" 600 517-914 1200
36 x 60" 12" 200 517-715 2850 10" 400 517-815 2350 8" 800 517-915 1900
36 x 72" 12" 250 517-716 3400 10" 500 517-816 2850 8" 1000 517-916 2300
48 x 48" 8" 200 517-717 2025 6" 400 517-817 1525 6" 800 517-917 1500
48 x 60" 12" 250 517-718 3800 10" 500 517-818 3150 8" 1000 517-918 2525
48 x 72" 12" 300 517-719 4500 10" 600 517-819 3800 8" 1200 517-919 3050
48 x 84" 14" 350 517-720 6150 12" 700 517-820 5325 10" 1400 517-920 4450
48 x 96" 14" 400 517-721 7000 12" 800 517-821 6050 10" 1600 517-921 5150
48 x 108" 14" 500 517-722 7900 12" 1000 517-822 6830 10" 2000 517-922 5700
48 x 120" 18" 700 517-723 11300 16" 1400 517-823 10160 14" 2800 517-923 8800
48 x 144" 18" 800 517-724 13500 16" 1600 517-824 12200 14" 3200 517-924 10500
60 x 60" 14" 250 517-725 5500 12" 500 517-825 4800 10" 1000 517-925 4000
60 x 72" 14" 350 517-726 6600 12" 700 517-826 5750 10" 1400 517-926 4900
60 x 96" 14" 500 517-727 8800 12" 1000 517-827 7600 10" 2000 517-927 6500
60 x 120" 16" 700 517-728 11050 14" 1400 517-828 11100 12" 2800 517-928 9800
60 x 144" 18" 900 517-729 16950 16" 1800 517-829 15100 14" 3600 517-929 14200
72 x 72" 14" 400 517-730 8000 12" 800 517-830 7000 10" 1600 517-930 5700
72 x 96" 16" 500 517-731 12025 14" 1000 517-831 10800 12" 2000 517-931 9200
72 x 120" 16" 700 517-732 15070 14" 1400 517-832 13400 12" 2800 517-932 11400
72 x 144" 18" 1000 517-733 20300 16" 2000 517-833 18100 14" 4000 517-933 15900
U-3
U-04 (2003) full size 12/8/03 9:24 AM Page 1
GRANITE PRODUCTS
Steel Stands
FOR BLACK GRANITE SURFACE PLATES
Specifications
Steel Stands
Inch
Stationary With Casters
Size Order No. Wt. Order No. Wt.
12 x 18" 517-950 42lbs 517-950-1 46lbs
18 x 18" 517-951 46lbs 517-951-1 50lbs
18 x 24" 517-952 50lbs 517-952-1 56lbs
24 x 24" 517-954 65lbs 517-954-1 69lbs
24 x 30" 517-955 70lbs 517-955-1 74lbs Note: The total height of stand and granite plate is
36". If ordering only stand, stand height will be made
24 x 36" 517-956 73lbs 517-956-1 77lbs
according to a Grade A granite plate thickness.
24 x 48" 517-957 90lbs 517-957-1 94lbs
30 x 36" 517-960 85lbs 517-960-1 89lbs
30 x 48" 517-961 95lbs 517-961-1 99lbs
30 x 60" 517-962 105lbs 517-962-1 109lbs
36 x 36" 517-963 95lbs 517-963-1 99lbs
36 x 48" 517-964 105lbs 517-964-1 109lbs
36 x 60" 517-965 160lbs 517-965-1 164lbs
36 x 72" 517-966 180lbs 517-966-1 184lbs
48 x 48" 517-967 190lbs 517-967-1 194lbs
48 x 60" 517-968 200lbs 517-968-1 204lbs
48 x 72" 517-969 205lbs 517-969-1 209lbs
48 x 84" 517-970 320lbs 517-970-1 324lbs
48 x 96" 517-971 335lbs 517-971-1 339lbs
48 x 108" 517-972 350lbs 517-972-1 354lbs
48 x 120" 517-973 365lbs 517-973-1 369lbs
48 x 144" 517-974 430lbs 547-974-1 434lbs
60 x 60" 517-975 245lbs
60 x 72" 517-976 340lbs
60 x 96" 517-977 375lbs
60 x 120" 517-978 455lbs
60 x 144" 517-979 480lbs
72 x 72" 517-980 380lbs
72 x 96" 517-981 465lbs
72 x 120" 517-982 510lbs
72 x 144" 517-983 530lbs
Wt. = Weight(lbs)
U-4
U-05 (2003) full size 12/8/03 9:24 AM Page 1
GRANITE PRODUCTS
Accessories
Series 517
FOR BLACK SURFACE PLATES
517-774 517-862
(with Inserts) (without Insert)
517-852
Parallels
(in pairs)
Specifications
Angle Blocks (With or Without Inserts)
Grade Laboratory* Master**
4 Face 4 Face
Size 2 Face no Inserts w/Inserts 2 Face no Inserts w/Inserts Case
4 x 4 x 4" 517-767 517-761 517-773 517-867 517-861 517-873 050021
6 x 6 x 6" 517-768 517-762 517-774 517-868 517-862 517-874 050022
**Laboratory overall accuracy: .000025" per 6".
**Master overall accuracy: .000050" per 6".
Parallels (Pair)
Grade Laboratory Master
Size Accuracy 2 Face 4 Face Accuracy 2 Face 4 Face Case
3/ x 1 x 6" .00003" 517-755 517-750 .00006" 517-855 517-850 050027
4
3/ x 11/ x 9" .00004" 517-756 517-751 .00008" 517-856 517-851 050028
4 2
1 x 2 x 12" .00006" 517-757 517-752 .0001" 517-857 517-852 050029
V-Blocks (Matching Pair)
V-1 type have matching accuracy on "V" from the bottom face only.
V-5 type have four face matching accuracy plus "V".
Grade Laboratory* Master**
Size V-1 V-5 V-1 V-5 Case
2 x 2 x 21/2" 517-787 517-783 517-887 517-883 050039
3 x 3 x 3" 517-788 517-784 517-888 517-884 050040
6 x 6 x 6" 517-789 517-785 517-889 517-885 050022X2
**Laboratory overall accuracy: .00005" per 6".
**Master overall accuracy: .0001" per 6".
U-5
V-01 (2003) full size 12/11/03 3:41 PM Page 1
Height Master
High Accuracy CERA Height Master - Series 515 V-2
Height Master - Series 515 V-3
Digimatic E-Type Height Master - Series 515 V-4
E-Type Height Master - Series 515 V-5
Height Master - Series 515 - Vertical, Horizontal V-6
Riser Block - Series 515 V-6
Clamping Block Set for Bore Gage V-7
Check Masters - Ceramic and Steel Blocks V-8, V-9
Caliper Checker - Series 515 V-10
Depth Micro Checker V-10
Cera Straight Master V-11
V-02 (2003) full size 12/8/03 9:16 AM Page 1
HEIGHT MASTER
Specifications
High Accuracy CERA Height Master
Inch/Metric
Order No. Range Block arrangement Block step Resolution Weight
515-342A .2"–12" Staggered. 1 inch .000005"/.0001mm 39.6 lbs
*SPC Connecting Cables No. 936937 (1m) or 965014 (2m).
V-2
V-03 (2003) full size 12/8/03 9:17 AM Page 1
HEIGHT MASTER
Height Master
Series 515
The Height Master features a stack of reference blocks
and a speed dial type micrometer head housed in a rigid,
cast iron frame.
Features
• Contains accurate reference block stack, which easily
provides a desired height.
• Models with staggered design of block stack have two 515-310
measuring faces on the same level, one facing up and
the other facing down. (515-311, 515-322)
• Speed dial type micrometer head for rapid setting of
desired heights.
• Rigid construction to ensure stable height measurement
and a long service life.
• Three carbide tipped pads lapped to serve as an accu-
rate reference on the surface plate and ensure durability.
• Each Height Master is supplied with a gage block for
zero setting.
• Fitted wooden case supplied.
Certificate of Accuracy
Each MITUTOYO Height Master is supplied with a
Certificate of Accuracy traceable to the National Institute
of Standards and Technology. It certifies the measuring
block accuracy, (which is calilbrated from surface plate to
the top land of each measuring block) and lead screw
accuracy.
Dimensions
• 5.9"(W) x 17.1"(H) x 5.3"(D)
Optional accessories
515-119 Clamping Block kit for Bore Gage (515-310)
515-121 Clamping Block kit for Bore Gage (515-311)
515-112 Clamping Block kit for Bore Gage (515-322)
Riser Blocks (See listing)
Specifications
Height Master
Inch
Block Block Block Pitch Parallelism Micrometer Head
Order No. Range Arrangement Step Graduation Accuracy of Block Accuracy Weight
515-310 .2–12.5" Straight .5" .00001" ±.00005" .00004" ±.00005" 47.1 lbs
515-311 .2–12.5" Staggered 1" .00001" ±.00005" .00004" ±.00005" 50.6 lbs
Metric
Block Block Block Pitch Parallelism Micrometer Head
Order No. Range Arrangement Step Graduation Accuracy of Block Accuracy Weight
515-322 5–310mm Staggered 20mm 0.001mm ±1.5µm ±1µm ±1µm 23 kg
V-3
V-04 (2003) full size 12/8/03 9:17 AM Page 1
HEIGHT MASTER
Digimatic E-Type
Height Master
Series 515 Application Examples
with Accessories
Calibrates
These E-Type Height Masters have a built-in LCD Dial Bore Gages
probe movements
Readout with resolution to .0001"/0.001mm. With the Two-point contact
easy to read Digimatic display, height calibration is made Dial Bore Gage with
roller guide
quick and efficient with virtually no chance of reading
error. SPC output is also provided for record keeping and
Base Block
data processing.
Features
• Standard model with a digital display, featuring all
essential specifications required for a versatile height
standard.
Calibrates
• Functions of the display include: Rod-type or
Extension-type
Zero-setting, Origin setting, Origin restoration, Inch/mm inside micrometers
Specifications
Digimatic E-Type Height Master
Inch/Metric
LCD Parallelism Micrometer Head
Order No. Range Resolution of Block Accuracy Height Weight
515-355 .5–12" .0001"/0.001mm .00005" ±.0001" 19.0" 20.9 lbs
515-357 .5–18" .0001"/0.001mm .0001" ±.0001" 24.9" 29.9 lbs
515-359 .5–24" .0001"/0.001mm .0001" ±.0001" 30.8" 35.2 lbs
E-Type Height Master
Metric
LCD Parallelism Micrometer Head
Order No. Range Resolution of Block Accuracy Height Weight
515-354 10–310mm 0.001mm 0.002mm ±0.002mm 482mm 9.5kg
515-356 10–460mm 0.001mm 0.0025mm ±0.002mm 632mm 13.6kg
515-358 10–610mm 0.001mm 0.0025mm ±0.0025mm 782mm 16.0kg
V-4
V-05 (2003) full size 12/8/03 9:17 AM Page 1
HEIGHT MASTER
Optional Accessories
050019 Fitted Mahogany Case
515-111 Clamping Block Set for Bore Gages
Riser blocks (See listing)
1"
BLOCK
Staggered blocks
make it possible
to transfer top and
bottom land heights
Specifications
E-Type Height Master
Inch
Block Pitch Parallelism Micrometer
Order No. Range Graduation Accuracy of Block Head Accuracy Weight
515-319 .5–12" .0001" ±.0001" .0001" ±.0001" 20.9 lbs.
V-5
V-06 (2003) full size 12/8/03 9:18 AM Page 1
HEIGHT MASTER
Series 515
18", 24" and 40" Models
Vertical or Horizontal Application
Riser Block
Series 515
Features
• Riser Blocks are specially designed and precisely
made to maintain the stipulated basic accuracy of
both Standard and E-type Height Masters. They are
available in two accuracy grades for each height,
and, in 6", 12", 24", 150mm and 300mm heights.
• The seasoned, cast-iron Riser Blocks sit on three car-
bide-faced and lapped pads which assure perpendicu-
larity to the surface plate. The Height Masters, in turn,
fit onto three carbide-faced seating pads on the Riser
Blocks, and, are accurately positioned by two locating
pins.
Dimensions
• 5.9"(W)x5.3"(D) for 6" and 12"
• 9.0"(W)x7.5"(D) for 24"
• Certificate of inspection is attached.
6" 12" 24"
Specifications
Riser Block
Inch
Order No. Size Accuracy Dim W x D Weight
515-116 6" ±.00002" 5.9" x 5.3" 12.5 lbs
515-117 12" ±.00004" 5.9" x 5.3" 24.9 lbs
515-118 24" ±.00008" 9.0" x 7.5" 68.0 lbs
Metric
Order No. Size Accuracy Dim W x D Weight
515-113 150mm ±0.0006mm 150mm x 135mm 5.7 kg
515-114 300mm ±0.001mm 150mm x 135mm 11.3 kg
V-6
V-07 (2003) full size 12/8/03 9:18 AM Page 1
HEIGHT MASTER
Specifications
Clamping Block Set for Bore Gage
Inch
Set Configuration
.7–1.4" 1.4–6" Clamp Ref.
Order No. Applicable Height Master Block Block Box Block
515-119 Height Master (Block Pitch .5") 900439 900440 900385 102394
515-121 Height Master (Block Pitch 1") 900439 900440 900882 102394
515-120 E-type & Digimatic Height Master 900889 900890 900882 102394
Metric
Set Configuration
18-35mm 35-150mm Clamp Ref.
Order No. Applicable Height Master Block Block Box Block
515-112 Height Master (Block Pitch 20mm) 900437 900438 900881 102355
515-111 E-type & Digimatic Height Master 900887 900888 900881 102355
V-7
V-08 (2003) full size 12/8/03 9:19 AM Page 1
HEIGHT MASTER
Check Masters
(Ceramic Block and Steel Block)
Features
• Can be used in either vertical or horizontal orientation.
• Dimensions (W x H) of the measuring face:
.35"x.39"/9 x 10mm.
• Indicating the instrumental errors on the plate at inter-
vals of 1"/20mm makes it unnecessary for the user to
515-761
consult with the certificate of inspection each time an
error compensation is performed.
Specifications for CERA Check Master:
• Each measuring block is made of zirconia-based
ceramic.
• No anti-corrosion treatment is required for measuring
faces.
• Abrasion resistance of the ceramic block is 5 - 10
times that of steel.
• Free from deterioration and dimensional changes over
time. Optional
Support
Optional Accessory
Base
Support Base (601167)
601167
• Provides enhanced stability for vertical orientation.
• Dimensions
14.2"(W) x 8.3"(H) x 8.7"(D)
Size Plate
Indicates instrumental
errors at intervals of
1"/20mm +0.5 +0.2
3 4 5
(Example)
Side
P P
(80mm)
3.2"
P
Base
Note: P
A Zero point
1.9" 300mm, 12" models
do not have hand
(50m hold openings.
m)
V-8
V-09 (2003) full size 12/8/03 9:20 AM Page 1
HEIGHT MASTER
Specifications
Check Masters
Ceramic/Inch
Accuracy of block pitch for the range shown
Order No. Range Pitch below as measured from the bottom block Length Parallelism Weight
P p up to 12" 12"-24" 24"-40" 40"-60"
515-750 12" 1" .5" ±50µin 13.0" 40µin 7.5 lbs.
515-751 18" 1" .5" ±50µin ±70µin 19.0" 40µin 11.5 lbs.
515-752 24" 1" .5" ±50µin ±70µin 25.0" 60µin 15.2 lbs.
515-753 40" 1" .5" ±50µin ±70µin ±100µin 41.0" 60µin 25.4 lbs.
515-754 60" 1" .5" ±50µin ±70µin ±100µin ±158µin 61.5" 80µin 38.1 lbs.
Ceramic/Metric
Accuracy of block pitch for the range shown
Order No. Range Pitch below as measured from the bottom block Length Parallelism Weight
P p up to 300– 600– 1000–
300mm 600mm 1000mm 1500mm
515-760 300mm 20mm 10mm ±1.2µm 331mm 1µm 3.4 kg
515-761 450mm 20mm 10mm ±1.2µm ±1.8µm 482mm 1µm 5.2 kg
515-762 600mm 20mm 10mm ±1.2µm ±1.8µm 631mm 1.5µm 6.9 kg
515-763 1000mm 20mm 10mm ±1.2µm ±1.8µm ±2.5µm 1037mm 1.5µm 11.5 kg
515-764 1500mm 20mm 10mm ±1.2µm ±1.8µm ±2.5µm ±4.0µm 1546mm 2µm 17.3 kg
Check Masters
Steel/Inch
Accuracy of block pitch for the range shown
Order No. Range Pitch below as measured from the bottom block Length Parallelism Weight
P p up to 12" 12"-24" 24"-40" 40"-60"
515-730 12" 1" .5" ±50µin 13.0" 40µin 7.9 lbs.
515-731 18" 1" .5" ±50µin ±70µin 19.0" 40µin 11.9 lbs.
515-732 24" 1" .5" ±50µin ±70µin 25.0" 60µin 15.9 lbs.
515-733 40" 1" .5" ±50µin ±70µin ±100µin 41.0" 60µin 26.5 lbs.
515-734 60" 1" .5" ±50µin ±70µin ±100µin ±158µin 61.5" 80µin 39.7 lbs.
Steel/Metric
Accuracy of block pitch for the range shown
Order No. Range Pitch below as measured from the bottom block Length Parallelism Weight
P p up to 300– 600– 1000–
300mm 600mm 1000mm 1500mm
515-740 300mm 20mm 10mm ±1.2µm 331mm 1µm 3.6 kg
515-741 450mm 20mm 10mm ±1.2µm ±1.8µm 482mm 1µm 5.4 kg
515-742 600mm 20mm 10mm ±1.2µm ±1.8µm 631mm 1.5µm 7.2 kg
515-743 1000mm 20mm 10mm ±1.2µm ±1.8µm ±2.5µm 1037mm 1.5µm 12.0 kg
515-744 1500mm 20mm 10mm ±1.2µm ±1.8µm ±2.5µm ±4.0µm 1546mm 2µm 18.0 kg
V-9
V-10 (2003) full size 12/8/03 9:15 AM Page 1
HEIGHT MASTER
Caliper Checker
Series 515
The Caliper Checker is designed to calibrate vernier, dial
and Digimatic calipers and height gages of various types. It
is comprised of permanently wrung, high-grade ceramic
(cera) gage blocks in a protective casting. The Caliper
Checker also stands perpendicular to a surface for height
gage inspection.
Dimensions
14.8"(375mm) W x 2.0(50mm) D x 2.4"(60mm)H
515-565
Length to check
515-565 1",2",4",6",8",10",12"
515-555 20mm, 50mm, 100mm, 150mm, 200mm, 250mm, 300mm
Specifications
Accuracy
Order No. Range Block pitch Parallelism Weight
515-565 12" ±.0002" 80µinch 8.8 lbs.
Checking accuracy of Dial Caliper using
515-555 300mm ±5µm 2µm 4 kg.
Caliper Checker.
Specifications
Accuracy
Order No. Range Checking Step Main Body Anvil Block
515-575 6" 1" ±(40+6.7L)µ inch ±20µ inch
L=Measuring Length
V-10
V-11 (2003) full size 12/8/03 9:16 AM Page 1
HEIGHT MASTER
Features
• The Cera Straight Master is for the inspection of straight- • This light weight, easy to carry straightness, master is
ness of each axis of a Coordinate Measuring Machine made of alumina ceramics.
(CMM), machine tools, semiconductor related equipment, • Alumina ceramics has little secular change.
and form measurement machine. • Supplied with a sturdy wooden case and 3 support legs.
Specifications
Order No. Range Overall Length Size Straightness Weight
311-322-33 16" 17.32" .000012" 3.97 lbs.
311-302-33 400mm 440mm 1.38 x 1.97" 0.0003mm 1.8 kg
311-325-33 28" 28.13" (35 x 50mm) .000020" 6.61 lbs.
311-305-33 700mm 740mm 0.0005mm 3 kg
311-327-33 40" 40.94" .000040" 17.64 lbs.
311-307-33 1000mm 1040mm 1.77 x 3.15" 0.001mm 8 kg
311-329-33 50" 52.76" (45 x 80mm) .000060" 22.05 lbs.
311-309-33 1300mm 1340mm 0.0015mm 10 kg
Remark: Over 40" (1000mm) range includes carrying handle.
V-11
W Section (2003) 12/14/03 11:13 AM Page 1
ALPHABETICAL INDEX
Accessories and System Diagram for Surftest Bench Centers ....................................967 .............S-37
SJ-401/402 .........................................................B-9 Bench Comparators............................162 .............S-37
Accessories and System Diagram for SV-C3000/ Bench Comparators - (w/Black Granite Bases) .....R-95
4000 Series.........................................................B-5 Black Granite Surface Plates .............517 .............J-5, U-2, 3
W-1
W Section (2003) 12/14/03 11:13 AM Page 2
ALPHABETICAL INDEX
W-2
W Section (2003) 12/14/03 11:13 AM Page 3
ALPHABETICAL INDEX
DEPTH GAGES Dial Gage Stands with Flat or Grid Anvil ..............R-91
Back Plunger Dial Depth Gages...........................Q-4 Dial Gage Testers...............................170 .............J-10, R-45
Depth Micrometers..........................129 .............Q-7 Dial Gage Tester - i-checker ..............170 .............R-43, 44
Dial Depth Gages - for Rapid, Direct Reading Dial Gage Upright Stand No. 7056 Complete
Meas. of Hole Depth............................................Q-3 w/Dial Indicator .....................................................R-101
Dial Depth Gages .............................527 .............Q-11 Dial Height Gages ..............................509 .............P-15
Digimatic Depth Gages with Absolute Dial Indicator - Dial Gage Tester .......170 .............J-10
Encoder ...........................................547 .............Q-2 Dial Indicator Dial Faces - Five Group Sizes -
Digimatic Depth Gages with Order by the Numbers............................................R-47-48
Absolute Encorder. ..........................571 .............Q-9 Dial Indicators - Group 0/1/2/3/4...........................R-46
Digimatic Depth Gage......................700 .............Q-10 Dial Indicators/Group O - Inch/Metric ...................R-56
Digimatic Depth Micrometers..........329 .............Q-5 Dial Indicators/Group 1 - Inch/Metric....................R-57~60
Digit Depth Micrometers - Interchangeable Dial Indicators/Group 2 - Inch/Metric....................R-61~68
Rod Type......................................... 229 ............Q-6 Dial Indicators/Group 3 - Inch/Metric....................R-69~72
Half-Base Depth Micrometers..........129 .............Q-8 Dial Indicators/Group 4 - Inch/Metric....................R-73~76
Vernier Depth Gages........................527 .............Q-12 Dial Snap - High Accuracy Go/
Depth Micro Checker .............................................V-10 No-Go Gage ........................................523 .............L-28
Depth Micrometer - Depth Micro Dial Tension Gages ............................546 .............R-117
Checker...............................................515 .............J-11 Dial Thickness Gages ............................................R-109, 110
Detectors and Styli for RA-H5000/2000/1500/ Dial/Digimatic Indicator and Stand Sets...............R-104
1400/100 Series.....................................................D-8
Diamond Master Vernier Calipers .....522 .............O-35
Detectors, Styli and Nosepieces
DIC Units for FS Objectives ...................................F-18
for SJ-400, SV-2000/3000, SV-C3000/
Differential Type Automatic - Gage Block
4000 Series.........................................................B-16, 17
Comparator - GBCD-100A......................................J-6
Dial Bore Gages .................................511 .............N-16, 17
Differential Type Manual - Gage Block
Dial Bore Gages - For Shallow Holes 511 .............N-20 Comparator - GBCD-250 ........................................J-7
Dial Bore Gages - Split-Ball Type......526 ...........N-14, 15 Differential Screw Translators...........110 .............M-4
Dial Bore Gages ................................545 .............N-30 Digi-Card................................................................K-12
Dial Bore Gages with Micrometer Digi-Derm...........................................179 .............S-36
Heads .................................................511 .............N-18, 19 Digimatic Bench Micrometer - w/Interchangeable
Dial Caliper Gages External Type .....209 .............R-113, 114 Anvil ...................................................121 .............L-34
Dial Caliper Gages Internal Type.......209 .............R-115~117 Digimatic Bore Gages ........................511 .............N-12, 13
Dial Calipers - "Quadri" (4-way) Digimatic Calipers w/Abs. Enc. - Featuring Position
Measurement .....................................505 ............O-9~12 Memory ..............................................500 .............O-3, 4
Dial Depth Gages ...............................527 .............Q-11 Digimatic Calipers w/Absolute Encoder -
Dial Depth Gages for Rapid, Direct Reading without output ....................................500 .............O-2
Meas. of Hole Depth..............................................Q-3 Digimatic Calipers with Absolute
Dial/Digimatic Indicator and Stand Sets...............R-105 Encoder...............................................550 .............O-13, 14
Dial Gage Stands 7003 - (with Serrated Anvil) and Digimatic Calipers with Absolute
7102 (with Flat Anvil) ............................................R-91 Encoder...............................................551 .............O-20
W-3
W Section (2003) 12/14/03 11:13 AM Page 4
ALPHABETICAL INDEX
Digimatic Can Seam Micrometer ......347 .............L-52 Digimatic Versa Gage ........................552 .............O-18, 19
Digimatic Carbon Fiber Calipers .......552 ............O-16, 17 Digit Depth Micrometers....................229 .............Q-6
Digimatic Chamfer Chek ....................547 .............N-36 Digit Micrometer Heads.....................250 .............M-17
Digimatic Depth Gage ........................700 .............Q-10 Digital Counter Type Height Gage .....192 .............P-13, 14
Digimatic Depth Gages w/Absolute Digital Hand Tachometers .................982 .............S-38
Encoder ..............................................547 .............Q-2
Digital Mini-Checker ..........................519 .............R-24
Digimatic Depth Gages with Absolute
Digital Outside Micrometers - Mech. Dig. Counter
Encoder...............................................571 ............Q-9
Readout ..............................................193 .............L-22, 23
Digimatic Depth Micrometers............329 .............Q-5
Digital Protractor ...............................950 .............S-3
Digimatic Difference/Sum Unit ..........572 .............K-17
Digital Tape Measure.........................216 .............S-8
Digimatic E-Type Height Master .......515 .............V-4
Digi-Test Digimatic Caliper Gages ....209 .............R-111, 112
Digimatic Extension Unit ...................572 .............K-18
Disc Micrometers - Rotating Spindle
Digimatic Height Gages
Type............................................323, 223, 123.....L-45, 46
Self-contained Electronic Inch/Metric
Disc Micrometers - Non-Rotating Spindle
Display.............................................192 .............P-11
Type................................................369, 169.........L-47, 48
Digimatic Holtests - Complete Unit
Drill Point Gage .....................................................S-14
Sets.....................................................468 ............N-26~29
Drive Pin Punches ..............................985 .............S-30
Digimatic Inside Calipers with Absolute
DRO (Integrated Scales and Sensors)
Encoder...............................................573 .............O-23, 24
Adapter Cross Reference.....................................I-6
Digimatic Micrometer - with or without
SPC output..........................................293 ............L-5 ABS-AOS Digital Readout System - AT715
Linear Scale ........................................................I-2
Digimatic Micrometer Heads (LCD readout).........F-20
Digimatic Micrometer Heads.............164 .............M-2 AT115 (Slim Spars), AT102 (Standard-size Spars)
(Extra-long Spars)...............................................I-7
Digimatic Micrometer Heads.............350 .............M-3
AT111 (Slim Spars), AT112 (Super-Slim Spars),
Digimatic Micrometer MDC-Lite........293 .............L-9
AT181 (Plunger-type Spars) ...............................I-7
Digimatic Micrometers - Rotating Spindle Type ..L-7, 8
AT-715 Schematic...............................................I-3
Digimatic Multi-Unit - 6 channel .......172 .............K-17
Check Sheet to Order AT211 ...............................I-18
Digimatic Plastic Calipers - Plasti-Cal700 ...........O-8
Check Sheet to Order ST34C...............................I-19
Digimatic Point Calipers with Absolute
Digimatic Scale Units - w/SPC Output.572 .............I-20
Encoder...............................................573 .............O-28
Digimatic Scale Units with Absolute
Digimatic Scale Units w/SPC Output .572 .............I-20
Encoder ...........................................572 .............I-22~24
Digimatic Scale Units with Absolute
DRO Optional Accessories ..................................I-6
Encoder...............................................572 .............I-22~24
Exposed Linear Encoder ST34C.......579 .............I-17
Digimatic Snap Calipers w/Absolute
Encoders.............................................573 .............O-15 Heavy Duty Digimatic Scale Units....572 .............I-21
Digimatic Solar Powered Caliper with Absolute Linear Scale - Applications..................................I-4
Encoder (Solar CD).............................500 .............O-5, 6 Linear Scale AT211 .............................................I-13
Digimatic Special Face Calipers with Absolute Linear Scale AT211 - (Substitute for
Encoder...............................................573 .............O-21, 22 AT21 and AT21-C) ...........................539 ............I-16
Digimatic Universal Protractor..............................S-5 Linear Scale AT332..........................539 .............I-14
Digimatic Upright Gage w/Absolute Encoder Tech....R-101 Linear Scale AT353..........................539 .............I-15
W-4
W Section (2003) 12/14/03 11:13 AM Page 5
ALPHABETICAL INDEX
W-5
W Section (2003) 12/14/03 11:13 AM Page 6
ALPHABETICAL INDEX
K AT211 .................................................................I-13
W-6
W Section (2003) 12/14/03 11:13 AM Page 7
ALPHABETICAL INDEX
W-7
W Section (2003) 12/14/03 11:13 AM Page 8
ALPHABETICAL INDEX
One-Revolution Dial Indicators - Group 1 & 2 ......R-77 Precision Granite Stands (w/Black Granite
One-Revolution Dial Indicators - Group 2 .............R-78 Bases).................................................517 .............R-95
Operational Guide and Tech. Data - Precision Hydraulic Vise .......................................S-21
Installing the Gage ................................................R-25, 26 Precision Levels.................................960 .............S-4
Optical Parallels ................................157 .............T-26 Precision Magnetic Sine Plates.........986 .............S-22
Optional Accessories and System Diagram for Precision Sine Plates.........................986 .............S-22
CV-1000/2000/3000/4000 Series...........................C-5 Precision Sine Vises ..........................986 .............S-20
Optional Accessories and System Diagram for
Precision Two and Three Dimensional
Surftest SJ-401/402 ...............................................B-9
Vises...................................................986 .............S-23
Optional Accessories for Contracers .....................C-9
Precision Vernier Calipers ........530, 531, 532.....O-32~34
Options for ES/EF/EV Counters - D-EV Display Unit...R-32
Precision Vises ..................................986 .............S-21
Order by the Numbers for Dial Indicators .............R-48~55
Profile Projectors - Standard Scales, Reading Scales,
Outside Micrometer - Micrometer
Overlay Charts .......................................................F-37
Standards ...........................................167 .............J-11
Projection Capacity for all types (T1, T2, T4) -
Outside Micrometer - Rectangular Gage Block
Profile Projectors...................................................F-29
Sets.....................................................516 .............J-11
Proscale .............................................950 .............I-25
Outside Micrometers..........................101 .............L-12
Protractor ...........................................187 .............S-6
Outside Micrometers..........................102 .............L-13
Outside Micrometers..........................103 .............L-14~17 Protractor - with Rectangular Base ...968 .............S-9
W-8
W Section (2003) 12/14/03 11:13 AM Page 9
ALPHABETICAL INDEX
Quick Vision Series 202- Quick Vision - Rockwell Type Diamond Indenters........................H-6
Quick Vision Hybrid 302/404/606 ..........................E-9 Rockwell Type Hardness Testing Machine AR-20...H-5
Quick Vision Hybrid Accel 404/606/808 ................E-10 Rockwell Type Hardness Testing Machine
Quick Vision Series 404 ........................................E-8 ARK-600 .................................................................H-4
Quick Vision Software - Optional Software: Rockwell/Rockwell Superficial Type Hardness
QV PartManager, QVTraceMaker ..........................E-12 Testing Machine ATK-600 .....................................H-4
Quick Vision Software - QV-Graph, MSHAPE-QV..E-12 Roll Calipers ......................................310 .............S-36
Quick Vision Software - Standard Software: QVPak, Roundpak V4.0 ......................................................D-7
Optional Software: Easypag ..................................E-11 Roundtest Optional Accessories - Gage, Chucks,
Quick Vision Software - CAD Option, Pagpak, Arm/Holder Extension............................................D-9, 10
Formpak-QV ...........................................................E-11 Roundtest RA-114..................................................D-6
Quill Kit ..................................................................I-21 Roundtest RA-116..................................................D-5
Roundtest RA-1400/1500.......................................D-4
R
Roundtest RA-2000 Series ....................................D-3
Radius Gages .....................................186 .............S-9, 10
Roundtest RA-H5000 Series..................................D-2
Reading Scales......................................................F-37
Reference Gage - Black Granite Surface S
Plates .................................................517 .............J-5 Screw Thread Micrometers .......326, 226, 126.....L-31, 32
Reference Gage - Gage Blocks..............................J-5 Scribers ..............................................985 .............S-30
Reference Gage - Rectangular & Square Gage Selection Guide - Scriber and Clamps .................P-2
Block Sets...........................................516 .............J-5 Selection Guide for Dial Indicators -
Remote Display Counters (SPC)............................K-16 Inch Models ...........................................................R-49
Remote Display Counters (DRO) ...........................I-20 Selection Guide for Dial Indicators -
Repair Tool Kit for Dial Indicators ........................R-90 Metric Models........................................................R-50
Rectangular Gage Block Accessories ..516 .............T-13~16 Selection Guide for Dial Indicators - One Revolution
Retangular Gage Block Sets - Inch ....516 .............T-4, 5 Type - Inch/Metric Back Plunger - Inch/Metric .....R-51
Retangular Gage Blocks - Selection Guide for Dial Indicators - Hicator &
Inch (Individual) .................................516 .............T-6, 7 Hicator II - Inch/Metric ..........................................R-52
Rectangular Gage Block Sets - Semi-Flexible Rules ..........................182 .............S-19
Metric .................................................516 .............T-8, 9 Setting Attachments ..............................................B-11
Rectangular Gage Blocks - Setting Rings......................................177 .............J-11, N-33
Metric (Individual) .............................516 .............T-10~12
Small Hole Gages ..............................154 .............S-28
Reticles for MF-A Models only..............................F-18
Snap Gages ........................................201 .............R-119, 120
Reticles for TM-505/510 ....................176 .............F-21
SPC (Data Management)
Ring Gage Calibration Equipment - Ring Master -
Data Collection and Processor (DP-1VR)............K-10
RM-120 ..................................................................J-9
Digimatic Difference/Sum Unit ........572 .............K-17
Riser Block .........................................515 .............V-6
Digimatic Extension Unit ................572 .............K-18
Rockwell and Rockwell Superficial Type Hardness
Tester .................................................810 .............H-3 Digimatic Multi-Unit .......................572 .............K-17
Rockwell Hardness Scales, Rockwell Superficial Input Tool .......................................264 .............K-11
Hardness Scales ....................................................H-2 MeasurLink SPC Software for Windows .............K-3~8
W-9
W Section (2003) 12/14/03 11:13 AM Page 10
ALPHABETICAL INDEX
Multiplexers for Real-Time Data Acquisition - Stands - Transfer (Heavy Duty Type) .519 .............R-99
Input Tool for keyboard & for
Stands - Universal Magnetic - 7019 (stand only) .R-100
RS-232C, Wireless Measure, MUX-200 & MUX-110,
Steel Ball Indenters ...............................................H-6
Digi-Card, MIG-2A, MIG-4, UP-1 &
Steel Rules .........................................182 .............S-17, 18
Interbox A/D....................................................K-12, 13
Steel Stands for Black Granite Surface Plates......U-4
Pocket ML - New Mobile solution to MeasurLink ..K-9
Steel Squares .....................................916 .............S-15
Remote Display Counters....................................K-16
Stereo Microscope MSM-414L/
SPC Connecting Cables.......................................K-15
MSM-414TL ........................................377 .............F-22
SPC Networkability - Measuring Solutions
Stereo Microscope MSM-465L/
w/MeasurLink .....................................................K-2
MSM-464L ..........................................377 .............F-24
Wireless Measure................................................K-14
Stereo Microscope .............................377 .............F-23
Voiceman - Portable Voice Output Device...........K-19
Stereo Microscope .............................377 .............F-25
Special Accessories for Gage Head ......................R-23 Styli for CV1000/2000/3000/4000 and
Special Accessories for Gage Head - SV-C3000/4000 ......................................................C-7, C-8
Air Drive Unit .........................................................R-21 Surface Gage......................................156 .............S-31
Spherical Face Micrometers .....395, 295, 115.....L-20, 21 Surface Roughness Detector, Styli, and Nosepieces for
Spline Micrometers ...................331, 131, 111.....L-43, 44 SJ-400, SV-2000/3000, SV-C3000/4000 Series....B-16, 17
Spring Dividers, Outside Spring Calipers, Surfpak-SJ, Surfpak-SV, Surfpak-PRO..................B-14
Inside Spring Calipers....................950 .............S-28 Surftest SJ-201P ....................................................B-11
Software (optional) CAD-Import & Export .............E-13 Surftest SJ-301 ......................................................B-10
Square Gage Block Accessories - Surftest SJ-401/402 ...............................................B-8
Inch/Metric .........................................516 .............T-23, 24 Surftest SV-2000/3000 Series ...............................B-6
Square Gage Block Sets - Inch ..........516 .............T-17 Surftest/Formtracer Optional Accessories for
Square Gage Blocks - Inch (Individual)516 ..........T-18, 19 SV-2000/3000, SV-C3000/4000.............................B-18
Square Gage Block Sets - Metric .......516 .............T-20 System Diagram for Contracer - CV-1000/2000/
Square Gage Blocks - Metric 3000/4000 Series...................................................C-5
(Individual).........................................516 .............T-21, 22 System Diagram for Formtracer - SV-C3000/
Standard Gages..................................950 .............S-14 4000 Series............................................................B-5
Standard Scales .................................172 .............F-37 System Diagram for SJ-201P/301 .........................B-11
Standard Scales .................................182 .............J-10 System Diagram for Surftest SJ-401/402..............B-9
Stands - Comparator ..........................215 .............R-92 T
Stand Sets - Dial/Digimatic Indicator ...................R-104 Tap and Drill Gage .............................950 .............S-14
Stands - Dial Gage - 7003 .....................................R-91 Tap Wrench - T-Handle..........................................S-29
Stands - Dial Gage Upright (No. 7056 Complete Telescoping Gages.............................155 .............S-29
w/Dial Indicator) ....................................................R-101
Thickness Gages ............................184, 950.........S-13
Stands - Flexi - 7012 (stand only) .........................R-100 Thread Gage ..........................................................S-14
Stands - Mini-Magnetic .........................................R-96, 97 3-Wire Thread Measuring System ........................L-30
Stands - Mini-Magnetic .....................984 .............R-98 TM-505, TM-505D, TM-510, TM-510D176............F-19
Stands - Multi Indicator.........................................R-102, 103 TM-505/510 - Reticles .......................176 .............F-21
Stands - Precision Granite .................517 .............R-95 Tool Kits .............................................950 .............L-60~64
W-10
W Section (2003) 12/14/03 11:13 AM Page 11
ALPHABETICAL INDEX
U
Uni-Mike - Interch. Anvil Type.......317, 117.........L-40
Universal Bevel Protractor.................187 .............S-6
Universal Magnetic Stand 7019 (stand only)........R-100
UP-1 & Interbox A/D ..............................................K-12
V
V-Anvil Micrometers - 3 Flutes and
5 Flutes...........................................314, 114.........L-49
V-Blocks and Clamps .........................181 .............S-24
Vernier Calipers - How to Read.............................O-30, 31
Vernier Calipers .............................160, 534.........O-36, 37
Vernier Depth Gages ..........................527 .............Q-12
Vernier Height Gages.........................506 .............P-16
Vickers Hardness - Knoop Hardness .....................H-7
Vision Unit..........................................359 .............F-4
VM Zoom 40 .......................................378 .............F-11~13
VMU Video Microscope Unit ..............378 .............F-14, 15
Voiceman - Portable Voice Output Device ............K-19
W
Wide Range Outside Micrometers -
w/Interch. Anvils ............................104, 340.........L-18, 19
Wireless Measure..................................................K-14
Working Standard Scale ....................182 .............J-10
Worldwide Accredited Calibration Laboratories...J-4
Z
Zero Adjustable Micrometer Heads ...152 .............M-15
Zero-it - 950-110....................................................S-32
Zero-Setter .........................................950 .............S-32
W-11
W Section (2003) 12/14/03 11:13 AM Page 12
NUMERICAL INDEX
121 Digimatic Bench Micrometer - w/Interchangeable 154 Small Hole Gages .....................................S-28
Anvil .........................................................L-34 155 Telescoping Gages ...................................S-29
W-12
W Section (2003) 12/14/03 11:13 AM Page 13
NUMERICAL INDEX
170 Dial Gage Tester - i-checker .....................R-43, 44 192 Digimatic Height Gages - Self-Contained
Elect. ........................................................P-11
170 Dial Indicator - Dial Gage Tester...............J-10
192 Digital Counter Type Height Gages ..........P-13, 14
172 PH-A14 -Horizontal Optical Comparator -
Profile Projectors .....................................F-32, 33 192 Heavy Duty Type Digimatic Height Gages...P-12
172 PH-3515F - Profile Projectors ..................F-30, 31 193 Digital Outside Micrometer - Mechanical
Digit Counter Readout ..............................L-22, 23
174 Linear Scale Digital Readout System
Counters ...................................................I-9, 10 197 Micrometer Heads....................................M-16
176 MF-A Measuring Microscopes - MFA500/ 201 Snap Gages ..............................................R-118, 119
1000 .........................................................F-2 209 Dial Caliper Gages External Type .............R-112, 113
176 MF-UA Measuring Microscopes ...............F-5, 6 209 Dial Caliper Gages Internal Type...............R-114~116
176 TM-505/510 - Toolmaker's Microscopes .F-21 209 Digi-Test Digimatic Caliper Gages ............R-110, 111
176 TM-505, TM-505D, TM-510, TM-510D - 215 Comparator Stands ..................................R-92~94
Toolmaker's Microscopes ........................F-19, 20 216 Digital Tape Measure................................S-8
177 Inside Micrometer & Bore Gage - Setting 223 Digital Disc Micrometers ..........................L-45, 46
Rings ........................................................J-11
226 Digital Screw Thread Micrometers ...........L-31, 32
177 Setting Rings............................................N-33
227 Adjustable Measuring Force Digimatic
179 Digi-Derm.................................................S-36 Micrometer...............................................L-26
179 Mu-Gage ..................................................S-35
227 Low Pressure Micrometers ......................L-25
179 Mu-Gage Plus...........................................S-34
229 Digit Depth Micrometers - Interchangeable
180 Combination Square Sets.........................S-16 Rod Type..................................................Q-6
181 V-Blocks and Clamps ...............................S-24 250 Digit Micrometer Heads - w/Mechanical
182 Hook Rules...............................................S-19 Counter Outside Thimble..........................M-17
182 Length Standard - Standard Scale............J-10 264 Input Tool.................................................K-11
W-13
W Section (2003) 12/14/03 11:13 AM Page 14
NUMERICAL INDEX
293 Coolant Proof Micrometer IP65................L-6 368 Holtests - Two Point Models for
293 Digimatic Micrometer MDC-Lite...............L-9 Very Small Holes ......................................N-21, 22
293 Digimatic Micrometers - with or without 368 Holtests - Interchangeable Anvil Type ......N-23~25
SPC output ...............................................L-5 369 Digimatic Disc Micrometers - Non
293 Digimatic Micrometers - Rotating Rotating Spindle Type ..............................L-47, 48
Spindle Type.............................................L-7, 8 377 Stereo Microscope MSM-414L/
MSM-414TL .............................................F-22, 23
293 Quickmike w/Absolute Encoder ................L-4
377 Stereo Microscope MSM-465L/
295 Digital Spherical Face Micrometers ..........L-20, 21
MSM-464L ...............................................F-24, 25
295 Digital Tubing Micrometers ......................L-36
378 Eyepiece ...................................................F-16
302 PJ-A3000 - Profile Projectors...................F-26, 27
378 FS70 High Power Microscopes ................F-7, 8
303 PJ-H3000F - Profile Projectors.................F-28
378 Objectives.................................................F-16~18
310 Roll Calipers .............................................S-36
378 VM Zoom 40 ............................................F-11~13
314 Digimatic V-Anvil Micrometers - 3 Flutes .L-49
378 VMU Video Microscope Unit ....................F-14, 15
317 Digimatic Uni-Mike - Interchangeable
389 Digimatic Deep Throat Micrometers -
Anvil Type.................................................L-40
For Sheet Metal and Similar Appl. ............L-53
318 Litematic ..................................................R-2, 3
395 Digimatic Spherical Face Micrometers .....L-20, 21
319 Microstages..............................................F-36
395 Digimatic Tubing Micrometers - Spherical
323 Digimatic Disc Micrometers .....................L-45 or Cylindrical ............................................L-36
324 Digimatic Gear Tooth Micrometers - 406 "Micron" Outside Micrometers - Non-Rotating
Interchang. Ball Anvil Type.......................L-29 Spindle for Flush Reading ........................L-10
326 Digimatic Screw Thread Micrometers ......L-31, 32 422 Digimatic Blade Micrometers - Non-Rotating
329 Digimatic Depth Micrometers...................Q-5 Spindle .....................................................L-37, 38
331 Digimatic Spline Micrometers ..................L-43, 44 468 Digimatic Holtests ....................................N-26, 27
337 Digimatic Tubular Inside Micrometers - 468 Digimatic Holtest - Complete Unit Sets ....N-28, 29
Extension Type .........................................N-6 500 Digimatic Calipers w/Absolute Encoders ..O-3, 4
339 Digimatic Tubular Inside Micrometers - 500 Digimatic Calipers w/Absolute Encoders -
Heavy Duty Type ......................................N-8 without SPC Output..................................O-2
340 Wide Range Outside Micrometers - 500 Digimatic Solar Powered Caliper w/Abs.
w/Interchangeable Anvils .........................L-18 Enc. (Solar CD).........................................O-5, 6
342 Crimp Height Type Micrometers - Point 500 Coolant Proof Digimatic Caliper w/Abs.
Spindle & Blade Anvil ...............................L-50 Enc. (IP-66)..............................................O-7
342 Digimatic Point Micrometers....................L-41, 42 504 Heavy Duty Dial Caliper ............................O-13, 14
343 Digimatic Caliper Type Micrometers.........L-35 505 Dial Calipers - Inch/Metric........................O-9~12
345 Digimatic Inside Micrometers ..................N-2, 3 506 Vernier Height Gages................................P-16
347 Digimatic Can Seam Micrometer..............L-52 509 Dial Height Gages.....................................P-15
350 Digimatic Micrometer Head - Compact Unit 510 Indicating Micrometer ..............................L-27
with 50 Millionths Reading.......................M-3 511 Dial Bore Gages........................................N-16, 17
359 Vision Unit................................................F-4 511 Dial Bore Gages w/Micrometer Heads ......N-18, 19
W-14
W Section (2003) 12/14/03 11:13 AM Page 15
NUMERICAL INDEX
511 Dial Bore Gages for Shallow Holes ...........N-20 517 Black Granite Surface Plates
511 Digimatic Bore Gages...............................N-12, 13 (Accessories) ...........................................U-5
513 Truetest Test Indicators............................R-120 517 Black Granite Surface Plates.....................J-5
513 Quick-Set Test Indicators .........................R-121, 122 517 Black Granite Surface Plates.....................U-2, 3
515 Caliper Checker ........................................V-10 517 Precision Granite Stands
515 Caliper & Height Gage - Caliper Checker ..J-10 (with Black Granite Bases) .......................R-95
515 Check Masters - Ceramic and Steel..........V-8, 9 518 Linear Height Lite 600 ..............................P-5
515 Clamping Block Set for Bore Gage ...........V-7 518 Linear Height LH-600B.............................P-3, 4
515 Coordinate Measuring Machine - 518 QM-Height - High Precision Digital .........P-6, 7
Check Master.............................................J-10 519 Digital Mini-Checker .................................R-24
515 Depth Micrometer - Depth Micro Checker ..J-11 519 Mu-Checkers - M400 Series for High
515 Digimatic E-Type Height Master ...............V-4 Accuracy...................................................R-22
515 E-Type Height Master...............................V-5 519 Transfer Stands (Heavy Duty Type)..........R-99
515 Inside Micrometer - Inside Micro 521 Calibration Testers ...................................R-45
Checker ....................................................J-11 522 Diamond Master Vernier Calipers.............O-35
515 Height Master...........................................V-3 523 Dial Snap Meters - High Accuracy
515 Height Master - Vertical or Horizontal Go/No-Go Gage ........................................L-28
Applications..............................................V-6 524 Hicator......................................................R-81, 82
515 High Accuracy CERA Height Master .........V-2 524 Hicator II - Dial Comparator .....................R-83
515 Riser Block ...............................................V-6 526 Chamfer Chek ..........................................N-35
516 Gage Block ...............................................T-2 526 Dial Bore Gages - Split-Ball Type..............N-14, 15
516 Maintenance Kit for Gage Blocks..............T-25 526 Hole-Chek - Instant Dia. Measurement of
516 Outside Micrometer - Rectangular Gage Small Holes ..............................................N-37
Block Sets ................................................J-11
527 Dial Depth Gages......................................Q-11
516 Rectangular Gage Block Accessories .......T-13~16
527 Vernier Depth Gages ................................Q-12
516 Rectangular Gage Blocks - Inch ...............T-6, 7
528 Knife Edge Straight Edge..........................S-15
516 Rectangular Gage Blocks - Metric ............T-10~12
530 Precision Vernier Calipers ........................O-32~34
516 Rectangular Gage Block Sets - Inch .........T-4, 5
531 Precision Vernier Calipers - with
516 Rectangular Gage Block Sets - Metric ......T-8, 9 Thumb Clamp............................................O-32~34
516 Rectangular Gage Block Sets ...................J-5 532 Precision Vernier Calipers - with Fine
516 Square Gage Block Accessories - Adjustment...............................................O-32~34
Inch & Metric ...........................................T-23, 24 534 Vernier Calipers - Long Jaw with Fine
516 Square Gage Blocks - Inch .......................T-18, 19 Adjustment...............................................O-36, 37
516 Square Gage Block Sets ...........................J-5 536 Low Pressure Dial Calipers.......................O-29
516 Square Gage Blocks - Metric ....................T-21, 22 536 Offset Dial Calipers...................................O-25, 26
516 Square Gage Block Sets - Inch .................T-17 536 Offset Vernier Calipers..............................O-25, 26
516 Square Gage Block Sets - Metric..............T-20 536 Vernier Offset Centerline Calipers.............O-27
W-15
W Section (2003) 12/14/03 11:13 AM Page 16
NUMERICAL INDEX
539 Linear Scales - AT-115, AT-112, AT-111, 572 Digimatic Difference/Sum Unit .................K-17
AT-102, AT-181........................................I-8 572 Digimatic Extension Unit ..........................K-18
539 Linear Scale - AT 211 (Substitute for AT21 & 572 Digimatic Multi-Unit - 6-Channel Multi-Point
AT21-C)....................................................I-16 Measuring Unit.........................................K-17
539 Linear Scale - AT332 - Substitute for AT31 572 Digimatic Scale Units - with SPC Output ....I-20
Real Absolute position..............................I-14
572 Digimatic Scale Units w/Absolute
539 Linear Scale - AT353 - Serial data Encoder ....................................................I-22~24
output of Abs............................................I-15
572 Heavy Duty Digimatic Scale Units -
543 IDC-CG Digimatic Indicators w/Abs. Enc. for w/Incremental Encoder.............................I-21
Bore Gage.................................................R-39
573 Digimatic Inside Calipers w/Absolute
543 IDC Type Digimatic Indicator w/Absolute Encoder........................................................O-23, 24
Encoder ....................................................R-35~37
573 Digimatic Point Calipers w/Absolute
543 IDC Type Digimatic Indicator w/Abs. Enc. & Encoder ....................................................O-28
Peak-Hold.................................................R-38
573 Digimatic Snap Calipers w/Absolute
543 IDF Digimatic Indicator w/Absolute Encoder - Encoder ....................................................O-15
Color Changing LCD.................................R-41, 42
573 Digimatic Special Face Calipers w/Absolute
543 IDS Digimatic Indicators w/Absolute Encoder ....................................................O-21, 22
Encoder ....................................................R-33, 34
573 Low Pressure Calipers - Digimatic ...........O-29
544 LSM-500H Series .....................................G-4
573 Offset Centerline Calipers - Digimatic.......O-27
544 LSM-9506 - Bench-Top Type ..................G-3
573 Offset Digimatic Calipers w/Absolute
544 LSM-6100 - Display Unit for
Encoder ....................................................O-25, 26
LSM-500H Series ......................................G-8
574 Heightmatic - High Precision Digital
544 LSM-902/6900 (Measurement Unit &
Height Gage..............................................P-8
Display Unit).............................................G-9
575 IDU Digimatic Indicator w/Abs. Enc. .......R-40
545 Dial Bore Gages - Rugged, Production-Line
Tools ........................................................N-30 579 Exposed Linear Encoder ST34C ...............I-17
547 Digimatic Chamfer Chek...........................N-36 700 MyCal Lite - Economy Digimatic Caliper ..O-8
547 Digimatic Depth Gages w/Absolute 700 Digimatic Plastic Calipers - Plasti-Cal.......O-8
Encoder ....................................................Q-2 810 Hardmatic - HH-401 - Rebound Type
550 Digimatic Calipers w/Absolute Encoders ..O-13, 14 Portable Hardness Tester .........................H-17
551 Digimatic Calipers w/Absolute Encoders ..O-20 810 Microhardness Testing System -
CCTV-Video...............................................H-10
552 Digimatic Carbon Fiber Calipers - Wide
Range Models ..........................................O-16, 17 810 New Rockwell & Rockwell Superficial Type
Hardness Tester .......................................H-3
552 Digimatic Versa Gage ...............................O-18, 19
811 Durometer - Digtal/Analog........................H-14, 15
568 Borematic w/Absolute Encoder ................N-31, 32
916 Steel Squares ...........................................S-15
570 HDS Digimatic Height Gage w/Absolute
Encoder ....................................................P-9, 10 950 Center Gage..............................................S-13
571 Digimatic Depth Gages w/Absolute 950 Depth Gage - Adjustable Angle.................S-12
Encoder ....................................................Q-9 950 Digital Protractor......................................S-3
W-16
W Section (2003) 12/14/03 11:13 AM Page 17
NUMERICAL INDEX
950 Pitch Gages ..............................................S-12 986 Precision Magnetic Sine Plates ................S-22
950 Pocket Steel Rule - with Pocket Clip.........S-19 986 Precision Hydraulic Vises.........................S-21
950 Proscale - ABS with Fraction/Decimal 986 Precision Sine Plates................................S-22
Reading ....................................................I-25 986 Precision Sine Vises.................................S-20
950 Spring Dividers, Outside Spring and Inside 986 Precision Two and Three Dimensional
Spring Calipers.........................................S-28 Vises ........................................................S-23
950 Standard Gages........................................S-14 986 Precision Vises.........................................S-21
950 Tap & Drill Gage .......................................S-14 2000 Roundtest RA-2000 Series.......................D-3
950 Thickness Gage - Inch..............................S-13 2000 Surftest SV-2000......................................B-6
950 Tool Kits ...................................................L-60~64 3000 Contracer - CV-3000 ................................C-2
950 Zero-Setter ...............................................S-32 3000 Formtracer SV-C3000...............................B-4
960 Precision Levels ......................................S-4 3000 Surftest SV-3000......................................B-6
963 Durotwin - Rockwell/Rockwell Superficial 4000 Contracer - CV-4000 ................................C-2
Type Hardness Testing.............................H-12
4000 Formtracer SV-C4000...............................B-4
967 Bench Centers ..........................................S-37
5000 Formtracer CS-5000 Series ......................B-2
968 Protractor - with Rectangular Base ..........S-9
5000 Roundtest RA-H5000 Series ....................D-2
980 Frame Winder...........................................S-7
7000 Dial Gage Stands ......................................R-91
980 Measuring Tapes......................................S-7
7000 Magnetic Stands.......................................R-84
980 Spirit Levels .............................................S-4
7000 Mini-Magnetic Stands ..............................R-96, 97
981 Angle Blocks.............................................S-33
7011 Magnetic Stands.......................................R-98
982 Digital Hand Tachometers ........................S-38
7012 Flexi-Stand ...............................................R-100
983 Datatorq - Digital Torque Wrenches w/SPC
7019 Universal Magnetic Stand.........................R-100
Output ......................................................S-39
7056 Dial Gage Upright Stand - complete with
984 Mini-Magnetic Stands ..............................R-98
Dial Indicator............................................R-101
985 Adjustable Parallels ..................................S-33
985 Center Punches ........................................S-30
985 Drive Pin Punches ....................................S-30
985 Parallel Clamps.........................................S-29
985 Scribers....................................................S-30
985 Tap Wrench (T-Handle) ............................S-29
986 Demagnetizers..........................................S-20
986 Magnetic Adjustable Links........................S-24
986 Magnetic Cubic Blocks .............................S-25
986 Magnetic Hexagonal Holder......................S-25
986 Magnetic Holders .....................................S-25
986 Magnetic Lamps.......................................S-32
986 Magnetic V-Blocks ...................................S-24
986 Permanent Magnetic Chucks....................S-26, 27
W-17
W Section (2003) 12/14/03 11:13 AM Page 18
WARRANTIES
W-18
2003 Inside Covers 12/19/03 1:29 PM Page 2
religion to all, along with the lasting wish for a peaceful world and fulfillment of
Distributed by: