A visual inspection was performed on the CE end winding. Ties, blocks, axial support
system, nuts and bar exits were well examined.
Heavy dusting was found at all connection ring- bar connections and moderate dusting in a
few positions as indicated in pictures below. This is the result of mechanical abrasion of the
insulation system due to movement in the end winding.
All axial support hardware was verified to be tight and all nuts well secured with locking tabs
in place. Minor oil contamination was present on the end winding TE side and frame floor.
Cleaning was performed with alcohol and rags. Corrective actions to dusting such as red eye
and flooding resin were applied on all suitable points after TIL 1965 was performed.
CORE IRON
A visual inspection on the Core Iron revealed that there was not mechanical damage,
shorted turns, or some signs of overheating; There were no signs of critically bent punching
or shorted lamination that could result in circulating current or overheating. No signs of
discoloration, burning or overheating were observed.
It was found light red dusting on belly band positions and axial supports.
It was observed that end of Slot on TE side presented black greasing generated by bar
movement and oil dropping from leakage on seal system of the generator. Below you can
find pictures of this findings and a boroscope inspection in order to find any possible damage
on bars.
WEDGES
The stator wedges were visually inspected for dusting that would indicate movement in the
slot during operation. No sign of looseness or critical damage was observed in this area.
BUSHINGS
All six, neutral and line bushing had the porcelain inspected and no cracks were found.
270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 929 of 1653
GE Power Power Services
270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 930 of 1653
GE Power Power Services
CR 2ock II CR 4ock I
CR 4ock II CR 6ock
270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 931 of 1653
GE Power Power Services
CR 12ock I CR 12ock II
270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 932 of 1653
GE Power Power Services
270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 933 of 1653
GE Power Power Services
270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 934 of 1653
GE Power Power Services
270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 935 of 1653
GE Power Power Services
270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 936 of 1653
Chilca Uno - Greasing on TE side.rev2
1 Summary
This report documents findings during Visual Inpection on Stator Core (As-found and After heating
Stator Core). It was oberseved that end of Slot on TE side presented black greasing generated by bar
movement and oil droping from leakage on lubrificant /seal system of the generator.
Below you can find pictures of this findings. The moviment of the bar in the slot together with oil
contamination can generate bar abrasion on stator bar and electrical failure or insulation weakeness.
The greasing was found visually on slot Ends on TE side, but it is recommended to perform a
borescope inspectionto find any damage on lateral bar.
2 Photos
As an attempt to troubleshoot the low Insulation Resistance (IR) measured on center phase of
generator stator 290T818, a borescope inspection was done on turbine end and collector end of
generator stator on February 14 - 16. The equipment tip passed through the vent slots of iron
packages in the core, reaching top and bottom bars in slot. The area covered in the inspection was
end (step) iron, where bar abrasion occurs mainly. 4th package of iron was also inspected to observe
side ripple spring migration.
The findings include dusting and greasing contamination in slots, but no visual evidence of bar
abrasion was found. The possibility of Bar was not removed as this damage could be occurring
between Bar and Step Iron, that is not possible to visually inspect without remove the wedges.
270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 966 of 1653
D3162041 Armature Winding Resista…
Comments
GE Proprietary and Confidential Information. Not to be distributed or reproduced to third parties without prior GE approval
D3162041 Sheet: (a) Rev 2.2 - 03/11/2020
270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 968 of 1653
D3162043 Stator Winding IR and HV Proof…
Stator Winding Insulation Resistance / HV Proof Tests
Generator Test & Inspection
Date 16/01/2021 Generator No.: 290T818 Prepared by: Renan Lopes
Equipment 324 Marina Anders
OEM GE Stator Voltage (kV): 18.0 Project ID: 10339092
DC INSULATION RESISTANCE (Megohms) per TM2030
Voltage: 5000 Volts
10 Minute Insulation Resistance
Time(Min) Left (CE) Center (CE) Right (CE)
0.5 525 360 968
1.0 1668 419 1775 12000
2.0 2820 460 2970
3.0 3970 480 3900 10000
4.0 4950 494 4870
5.0 5980 503 5650 M
E 8000
6.0 6970 510 6600
G
7.0 7950 515 7300 O
8.0 9120 518 8140 H 6000
9.0 9870 520 8560 M
S
10.0 10660 524 9220 4000
PI 6.4 1.3 5.2
Rule 1 PASS FAIL PASS
2000
Rule 2 PASS FAIL PASS
After Hipot1 min
0
Rule 3
0.0 2.0 4.0 6.0 8.0 10.0 12.0
TIME (Min.)
Conditions During Insulation Resistance
o
Winding Temperature ( C) 26 Left (CE) Center (CE) Right (CE)
Ambient Tempature (oC) 23
Relative Humidity (%) 69%
Insulation Type Thermal Setting (i.e. Micapal, Isotenax, >1960)
Corrected Resistance1 minute at 40°C IEC 60034-27 Left (CE) 1668 Center (CE) 419 Right (CE) 1775 Megohms
HIGH VOLTAGE PROOF TEST per TM2050
Test Series DC Recommended Test Voltage Actual Test Voltage
Stator Voltage 18.0 kV DC 45.9 kV DC kV
NOTES 1.) Prior to any high voltage testing, fill in D316218 and get customer agreement on test voltages.
2.) For DC, the test is performed at the end of the DC Leakage Test, use D3162044.
3.) For AC, record results below.
AC HIPOT RESULTS Left (CE) Center (CE) Right (CE) Conditions During HV Proof Test
Passed test at (kV) - 1 min. Winding Temperature (oC)
Failed test at [kV/Time(sec)] Ambient Temperature (oC)
Excitation Voltage (Volts) Relative Humidity (%)
Current (Amps)
Instrument Description ID No. CAL Exp. Date COMMENTS
Megger (MEGOhmeter) 101343997 08/07/2021
GE Proprietary and Confidential Information. Not to be distributed or reproduced to third parties without prior GE approval
D3162043 Sheet: (a) Rev 2.1 - 08/05/2020
270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 970 of 1653
D316403 RTD Test Dual Element
RTD Test
Dual Element - Copper, Nickel, Platinum or Special
Date 2/24/21 Generator Serial No. 290T818 Prepared By Marília Oliveira
Erica Koono
Turbine Serial No. 270T818 Project ID C-10339092
Test Article Reference: TM2010
Winding Temperature: 42 ºC
GE Proprietary and Confidential Information. Not to be distributed or reproduced to third parties without prior GE approval
D316403 Sheet: 1 thru 12 Rev 3.1 - 05/15/2020
RTD Test
Dual Element - Copper, Nickel, Platinum or Special
Date 2/24/21 Generator Serial No. 290T818 Prepared By Marília Oliveira
Erica Koono
Turbine Serial No. 270T818 Project ID C-10339092
Winding Temperature: 42 ºC
Device: Fluke 287
Type must be entered as follows: C, N, P or O. *See Note below.
RTD RTD RESISTANCE Indicated Customer
Remarks
No. Type* AB AC BC (AB+AC)/2 - BC Temp. ºC Temp ºC
13
13'
14
14'
15
15'
16
16'
17
17'
18
18'
19
19'
20 P 119.13 119.13 1.94 117.19 44.65 SLOT 14 - CENTER/TE
20' P 119.20 119.20 1.99 117.21 44.70 SLOT 14 - CENTER/TE
21 P 118.78 118.75 1.69 117.08 44.35 SLOT 38 - CENTER/TE
21' P 118.68 118.70 1.70 116.99 44.13 SLOT 38 - CENTER/TE
22 P 118.00 117.99 1.72 116.28 42.27 SLOT 62 - CENTER/TE
22' P 117.99 117.97 1.75 116.23 42.16 SLOT 62 - CENTER/TE
23
23'
24
24'
*RTD Type must be entered as: C, N, P or O O = User Defined RTD Characteristics
Standard RTDs Material Name =
C = Copper 10 Ω @ 25 ºC Reference Resistance RREF = ohms
N = Nickel 120 Ω @ 0 ºC Reference Temperature TREF = ºC
P = Platinum 100 Ω @ 0 ºC (DIN Standard) Coefficient of resistance (α) =
Non-Standard RTDs ohms per ohm /per ºC
O = User defined as described at right RTD Information Source
Megger SN: 101343997 Calibration Date: 6/8/20 Due Date: 7/8/21
Fluke SN: 40380007 Calibration Date: 6/8/20 Due Date: 7/8/21
GE Proprietary and Confidential Information. Not to be distributed or reproduced to third parties without prior GE approval
D316403 Sheet: 13 thru 24 Rev 3.1 - 05/15/2020
RTD Test
Dual Element - Copper, Nickel, Platinum or Special
Date 2/24/21 Generator Serial No. 290T818 Prepared By Marília Oliveira
Erica Koono
Turbine Serial No. 270T818 Project ID C-10339092
Winding Temperature: 42 ºC
Device: Fluke 287
Type must be entered as follows: C, N, P or O. *See Note below.
RTD RTD RESISTANCE Indicated Customer
Remarks
No. Type* AB AC BC (AB+AC)/2 - BC Temp. ºC Temp ºC
25
25'
26
26'
27
27'
28
28'
29
29'
30
30'
31 P 118.53 118.61 1.89 116.68 43.32 SLOT 2 - CENTER/TE
31' P 118.47 118.49 1.82 116.66 43.27 SLOT 2 - CENTER/TE
32 P 119.40 119.41 1.94 117.47 45.36 SLOT 26 - CENTER/TE
32' P 119.43 119.40 1.91 117.51 45.47 SLOT 26 - CENTER/TE
33 P 118.00 118.01 1.58 116.43 42.66 SLOT 50 - CENTER/TE
33' P 117.96 117.96 1.58 116.38 42.55 SLOT 50 - CENTER/TE
34 P 117.41 117.41 1.18 116.23 42.16 SLOT 3 - CENTER/CE
34' P 117.40 117.39 1.17 116.23 42.14 SLOT 3 - CENTER/CE
35 P 117.01 116.99 1.06 115.94 41.40 SLOT 27 - CENTER/CE
35' P 118.48 118.46 1.22 117.25 44.81 SLOT 27 - CENTER/CE
36 P 118.38 118.38 1.21 117.17 44.60 SLOT 51 - CENTER/CE
36' P 116.95 116.96 1.00 115.96 41.44 SLOT 51 - CENTER/CE
*RTD Type must be entered as: C, N, P or O O = User Defined RTD Characteristics
Standard RTDs Material Name =
C = Copper 10 Ω @ 25 ºC Reference Resistance RREF = ohms
N = Nickel 120 Ω @ 0 ºC Reference Temperature TREF = ºC
P = Platinum 100 Ω @ 0 ºC (DIN Standard) Coefficient of resistance (α) =
Non-Standard RTDs ohms per ohm /per ºC
O = User defined as described at right RTD Information Source
Megger SN: 101343997 Calibration Date: 6/8/20 Due Date: 7/8/21
Fluke SN: 40380007 Calibration Date: 6/8/20 Due Date: 7/8/21
GE Proprietary and Confidential Information. Not to be distributed or reproduced to third parties without prior GE approval
D316403 Sheet: 25 thru 36 Rev 3.1 - 05/15/2020
RTD Test
Dual Element - Copper, Nickel, Platinum or Special
Date 2/24/21 Generator Serial No. 290T818 Prepared By Marília Oliveira
Erica Koono
Turbine Serial No. 270T818 Project ID C-10339092
GE Proprietary and Confidential Information. Not to be distributed or reproduced to third parties without prior GE approval
D316403 Sheet: RTD Megger Rev 3.1 - 05/15/2020
270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 975 of 1653
Bump Test_As Found
GE Proprietary Information. This document contains proprietary information of the General Electric Company and
may not be used or disclosed to others, except with the written permission of General Electric Company. 1
EXECUTIVE SUMMARY
This report contains results from a modal impact (bump) test on the end winding series loops and
phase connections of ST1 a GE generator S/N 290T818 at the Chilca Uno site in Lima, Peru on
January 19, 2021. An instrumented hammer was used to excite the generator components while an
accelerometer measured the response. Data was analyzed with a spectrum analyzer in real time and
the frequency response functions, in g/lb were obtained on both the turbine end (TE) and collector
end (CE) series loops and phase connections.
The turbine end series loop axial, radial, and tangential responses were acceptable and found within
limits. Plots of the data are shown in Enclosure 1 of Appendix B.
The collector end series loop axial, radial, and tangential responses were acceptable and found within
limits. Plots of the data are shown in Enclosure 2 of Appendix B.
The response for phase connection number CEPCBR001, CEPCBT001, CEPCBR003, CEPCBR013,
CEPCBT013, CEPCBT025, CEPCBR037, CEPCTT050, CEPCBT051, and CEPCBR063 exceeded the threshold
listed in table 1 of Appendix A. All other phase connection responses were acceptable and found within
limits. Plots of the data are shown in Enclosure 3 of Appendix B.
GE Proprietary Information. This document contains proprietary information of the General Electric Company and
may not be used or disclosed to others, except with the written permission of General Electric Company. 2
EQUIPMENT USED
PCB Model 338C04 Accelerometer, S/N 6045 and calibration due date 13AUG2021
PCB Model 086D20 Impact Hammer, S/N 20552 and calibration due date 13AUG2021
OROS OR24 4 Channel PC Based Spectrum Analyzer, S/N 008071 and calibration due date 12AUG2021
TEST OVERVIEW
An end winding vibration “bump” test is performed to determine the fundamental resonant frequency
and associated response value of the individual series loops and phase connections of a generator.
Data related to series loops and phase connections, which exceed current GE criteria, is relayed to GE
Generator Engineering where the results of these tests are analyzed to determine whether additional
support is required. Data related to series loops and phase connections, which appear around 60 and
120 Hz (or 50 and 100 Hz) will be relayed to site personnel for other OEM units.
TERMINOLOGY (SERIES LOOPS AND PHASE CONNECTIONS DATA PLOTS PER LOCATION)
(Appendix B Enclosures 1 through 3)
The left plot for each measurement location and direction is scaled with a frequency range of 0 to 200
Hz. The right plot is scaled for a range of [55 to 140] Hz and includes a horizontal amplitude line
identifying the engineering pass/fail threshold. At the upper left of each trace is a file name identifying
the measurement location and direction. The terminology used for Series Loops and Phase Connection
Data Plots per location is the following:
CEPCBT001.UFF
| | | | | --------------- Bar Number (1 to 72)
| | | | ----------------- A = Axial Direction, R = Radial Direction, T = Tangential Direction
| | | ------------------- B = Bottom Phase Connection; T = Top Phase Connection
| | ---------------------- PC = Phase Connection (No designation for Series Loops)
|-------------------------- CE = Collector End; TE = Turbine End
GE Proprietary Information. This document contains proprietary information of the General Electric Company and
may not be used or disclosed to others, except with the written permission of General Electric Company. 3
APPENDIX A
Acceptance Criteria
(Test data was compared to the amplitude threshold criteria outlined in table 1)
GE Proprietary Information. This document contains proprietary information of the General Electric Company and
may not be used or disclosed to others, except with the written permission of General Electric Company. 4
Table 1: Acceptance criteria for GE conventionally-cooled 324 generator resonance testing (2 pole, 60
Hz), Repair Engineering Instruction 503HA422 – 324 End Winding Blocking Upgrades
Series Loop
Measurement Phase Connection Applicable Frequency
Direction Threshold Threshold Range
Axial 0.5 g / lb 0.5 g / lb 55-70 Hz & 110-140 Hz
Radial 0.5 g / lb 0.5 g/ lb 55-70 Hz & 110-140 Hz
Tangential 0.5 g / lb 0.5 g / lb 55-70 Hz & 110-140 Hz
GE Proprietary Information. This document contains proprietary information of the General Electric Company and
may not be used or disclosed to others, except with the written permission of General Electric Company. 5
APPENDIX B
Test Data Plots
(Amplitude versus Frequency)
GE Proprietary Information. This document contains proprietary information of the General Electric Company and
may not be used or disclosed to others, except with the written permission of General Electric Company. 6
Enclosure 1
Turbine End Series Loop Frequency Responses
(Amplitude versus Frequency)
GE Proprietary Information. This document contains proprietary information of the General Electric Company and
may not be used or disclosed to others, except with the written permission of General Electric Company. 7
400m
30m
1 300m
Amplitude g/lbf
Amplitude g/lbf
23
20m
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
40m 2 400m
30m 3 300m
Amplitude g/lbf
Amplitude g/lbf
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m 1
300m
Amplitude g/lbf
Amplitude g/lbf
40m 32
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1
300m
Amplitude g/lbf
Amplitude g/lbf
2
20m
3 200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
30m 300m
Amplitude g/lbf
Amplitude g/lbf
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m 1
300m
Amplitude g/lbf
Amplitude g/lbf
40m
32
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
Amplitude g/lbf
20m
3 200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
40m 3 400m
30m 300m
Amplitude g/lbf
Amplitude g/lbf
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
Amplitude g/lbf
Amplitude g/lbf
100m
200m
1
23
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1
2 300m
Amplitude g/lbf
Amplitude g/lbf
20m
3
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1
400m
60m
2
300m
Amplitude g/lbf
Amplitude g/lbf
40m 3
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
Amplitude g/lbf
Amplitude g/lbf
50m
1
200m
2
3
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1
2 300m
Amplitude g/lbf
Amplitude g/lbf
20m 3
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
60m
2 300m
Amplitude g/lbf
Amplitude g/lbf
3
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
Amplitude g/lbf
Amplitude g/lbf
100m
200m
1
23 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
2 1
300m
Amplitude g/lbf
Amplitude g/lbf
20m 3
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m 1
2
300m
Amplitude g/lbf
Amplitude g/lbf
3
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
Amplitude g/lbf
Amplitude g/lbf
100m 1
200m
32 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1
2 300m
Amplitude g/lbf
Amplitude g/lbf
20m
3 200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
Amplitude g/lbf
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
Amplitude g/lbf
Amplitude g/lbf
100m
1 200m
2
3
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1
300m
Amplitude g/lbf
Amplitude g/lbf
2
20m
200m
3
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
300m
Amplitude g/lbf
Amplitude g/lbf
1
40m
3 2
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1
300m
Amplitude g/lbf
Amplitude g/lbf
20m 2
200m
3
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
60m
2 3
300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1
40m 32 400m
30m 300m
Amplitude g/lbf
Amplitude g/lbf
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1 300m
Amplitude g/lbf
Amplitude g/lbf
20m 2
200m
3
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
1
2 300m
Amplitude g/lbf
Amplitude g/lbf
40m 3
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1
2 400m
60m
300m
Amplitude g/lbf
Amplitude g/lbf
40m
3 200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m
Amplitude g/lbf
Amplitude g/lbf
10m 3
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
1
2 300m
Amplitude g/lbf
Amplitude g/lbf
3
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
30m 300m
Amplitude g/lbf
Amplitude g/lbf
3
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
Amplitude g/lbf
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
21
3
300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1 300m
Amplitude g/lbf
Amplitude g/lbf
20m
2
200m
10m 3
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
300m
Amplitude g/lbf
Amplitude g/lbf
1 2
40m 3
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
21 300m
Amplitude g/lbf
Amplitude g/lbf
20m 3
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1 300m
Amplitude g/lbf
Amplitude g/lbf
20m
2
200m
3
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1
40m 2 400m
3
30m 300m
Amplitude g/lbf
Amplitude g/lbf
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
300m
Amplitude g/lbf
Amplitude g/lbf
40m
1
2 200m
3
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1
300m
Amplitude g/lbf
Amplitude g/lbf
2
20m
200m
3
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
1
300m
Amplitude g/lbf
Amplitude g/lbf
40m 2
3
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
40m 1 400m
30m 32 300m
Amplitude g/lbf
Amplitude g/lbf
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
12 300m
Amplitude g/lbf
Amplitude g/lbf
20m 3
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
60m
2 3 300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
40m 400m
1
2
30m 300m
Amplitude g/lbf
Amplitude g/lbf
3
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1 300m
Amplitude g/lbf
Amplitude g/lbf
20m 2
200m
3
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
60m
300m
Amplitude g/lbf
Amplitude g/lbf
40m 2
3
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
40m 400m
30m 300m
Amplitude g/lbf
Amplitude g/lbf
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1
2 300m
Amplitude g/lbf
Amplitude g/lbf
20m
200m
3
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
40m 400m
2
3
30m 300m
Amplitude g/lbf
Amplitude g/lbf
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
12
300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
3
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1 300m
Amplitude g/lbf
Amplitude g/lbf
2
20m
200m
3
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m 1
2
300m
Amplitude g/lbf
Amplitude g/lbf
3
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m
Amplitude g/lbf
Amplitude g/lbf
40m
3 200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1 300m
Amplitude g/lbf
Amplitude g/lbf
2
20m
200m
10m 3
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m 2 1
3
300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
1 300m
Amplitude g/lbf
Amplitude g/lbf
100m
200m
32
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1 2
300m
Amplitude g/lbf
Amplitude g/lbf
20m
200m
3
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1
400m
60m 2
3
300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
1 300m
Amplitude g/lbf
Amplitude g/lbf
100m 2
200m
3
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1 300m
Amplitude g/lbf
Amplitude g/lbf
2
20m
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1
400m
60m
2 3 300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
1
300m
Amplitude g/lbf
Amplitude g/lbf
100m 2
200m
3
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1 300m
Amplitude g/lbf
Amplitude g/lbf
20m 2
3 200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
60m
3 2
300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1
400m
300m
Amplitude g/lbf
Amplitude g/lbf
2
50m
200m
3
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1 300m
Amplitude g/lbf
Amplitude g/lbf
20m
32
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
60m 2
3 300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
1
300m
Amplitude g/lbf
Amplitude g/lbf
40m 2
200m
3
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1 300m
Amplitude g/lbf
Amplitude g/lbf
20m
2
3 200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1
400m
60m
2 300m
Amplitude g/lbf
Amplitude g/lbf
40m 3
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
300m
Amplitude g/lbf
Amplitude g/lbf
3
20m
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m 2
3
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
60m
2
300m
Amplitude g/lbf
Amplitude g/lbf
3
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
2
300m
Amplitude g/lbf
Amplitude g/lbf
40m 3
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m 3
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m 1
2 300m
Amplitude g/lbf
Amplitude g/lbf
3
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m 1
300m
Amplitude g/lbf
Amplitude g/lbf
200m
200m
100m 23
100m
2 3
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
2
400m
60m
3
300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
300m
Amplitude g/lbf
Amplitude g/lbf
40m 2
3
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1 300m
Amplitude g/lbf
Amplitude g/lbf
20m
2 200m
3
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
2 400m
60m
3
300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
40m 400m
2
30m 300m
Amplitude g/lbf
Amplitude g/lbf
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1
300m
Amplitude g/lbf
Amplitude g/lbf
20m 2
200m
3
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
60m 2
3 300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
Amplitude g/lbf
Amplitude g/lbf
1
100m 23
200m
100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1
2 300m
Amplitude g/lbf
Amplitude g/lbf
20m 3
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
1
300m
Amplitude g/lbf
Amplitude g/lbf
2
40m 3
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m 1
2 300m
Amplitude g/lbf
Amplitude g/lbf
40m
3 200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1 300m
Amplitude g/lbf
Amplitude g/lbf
2
20m
200m
3
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
2 1
3 300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
300m
Amplitude g/lbf
Amplitude g/lbf
40m 2
3
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1 300m
Amplitude g/lbf
Amplitude g/lbf
20m 2
3 200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
60m
2
3 300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
300m
Amplitude g/lbf
Amplitude g/lbf
2
40m 3
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
300m
Amplitude g/lbf
Amplitude g/lbf
1
20m
2
200m
10m 3
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
60m 2
300m
Amplitude g/lbf
Amplitude g/lbf
3
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
40m 400m
30m 300m
Amplitude g/lbf
Amplitude g/lbf
2
3
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1 300m
Amplitude g/lbf
Amplitude g/lbf
20m
2
200m
10m 3
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m 1
2
300m
Amplitude g/lbf
Amplitude g/lbf
40m 3
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1
32 400m
60m
300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
3 300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m 1
2 300m
Amplitude g/lbf
Amplitude g/lbf
3
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
1
300m
Amplitude g/lbf
Amplitude g/lbf
50m 23
200m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1
300m
Amplitude g/lbf
Amplitude g/lbf
2
20m
200m
3
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m 1
2 3
300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
1
300m
Amplitude g/lbf
Amplitude g/lbf
32
50m
200m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
1
20m 2
3 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
2 3
300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
1
300m
Amplitude g/lbf
Amplitude g/lbf
40m
32
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
2 400m
15m
3
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1
2 400m
60m
3
300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
1 300m
Amplitude g/lbf
Amplitude g/lbf
40m
32 200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
2 1 400m
3
15m
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m 1
2
3 300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
1
300m
Amplitude g/lbf
Amplitude g/lbf
40m
2 3 200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
2 400m
15m
300m
Amplitude g/lbf
Amplitude g/lbf
10m 3
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m 1
2
3 300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
Amplitude g/lbf
20m
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
40m 400m
30m 300m
Amplitude g/lbf
Amplitude g/lbf
1
20m 200m
2
3
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
1
2
300m
Amplitude g/lbf
Amplitude g/lbf
40m 3
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
30m
2
3 300m
Amplitude g/lbf
Amplitude g/lbf
20m
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1 300m
Amplitude g/lbf
Amplitude g/lbf
20m
2
200m
3
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
40m 400m
2
3
30m 300m
Amplitude g/lbf
Amplitude g/lbf
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
321 300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
15m
2
3 300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
300m
Amplitude g/lbf
Amplitude g/lbf
20m
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
2 300m
Amplitude g/lbf
Amplitude g/lbf
20m 3
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1
2 400m
15m
3
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
30m 300m
Amplitude g/lbf
Amplitude g/lbf
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
1
300m
Amplitude g/lbf
Amplitude g/lbf
40m
2
200m
3
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
12 400m
15m
3 300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
Amplitude g/lbf
Amplitude g/lbf
100m
200m
2 1
3 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
300m
Amplitude g/lbf
Amplitude g/lbf
1
20m
3 2 200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1
2 400m
15m
3 300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
30m 300m
Amplitude g/lbf
Amplitude g/lbf
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1 300m
Amplitude g/lbf
Amplitude g/lbf
20m 2
3 200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
40m 2 3 400m
30m 300m
Amplitude g/lbf
Amplitude g/lbf
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1
300m
Amplitude g/lbf
Amplitude g/lbf
20m 3 2
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1 300m
Amplitude g/lbf
Amplitude g/lbf
20m
2 200m
3
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
Amplitude g/lbf
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m 1
300m
Amplitude g/lbf
Amplitude g/lbf
20m 3 2
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1 300m
Amplitude g/lbf
Amplitude g/lbf
20m
2
200m
3
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
Amplitude g/lbf
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
40m 400m
21
30m 300m
Amplitude g/lbf
Amplitude g/lbf
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1 300m
Amplitude g/lbf
Amplitude g/lbf
20m
2 200m
3
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
40m 2 3 400m
30m 300m
Amplitude g/lbf
Amplitude g/lbf
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
40m 400m
1
2
30m 300m
Amplitude g/lbf
Amplitude g/lbf
3
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
300m
Amplitude g/lbf
Amplitude g/lbf
1
20m
2 200m
3
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
1
300m
Amplitude g/lbf
Amplitude g/lbf
40m 2
3
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
1
300m
Amplitude g/lbf
Amplitude g/lbf
40m
2
3 200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
300m
Amplitude g/lbf
Amplitude g/lbf
1
20m 2
3 200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
1
300m
Amplitude g/lbf
Amplitude g/lbf
40m 2 3
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m
Amplitude g/lbf
Amplitude g/lbf
2 3
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m 1
2
300m
Amplitude g/lbf
Amplitude g/lbf
3
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
30m 3 300m
Amplitude g/lbf
Amplitude g/lbf
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
30m
2 300m
Amplitude g/lbf
Amplitude g/lbf
20m 3
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
15m
2
3
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
Amplitude g/lbf
Amplitude g/lbf
100m
200m
1 2 3
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
40m 400m
1
30m 2 300m
Amplitude g/lbf
Amplitude g/lbf
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
Amplitude g/lbf
Amplitude g/lbf
1
50m
3 2
200m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
300m
Amplitude g/lbf
Amplitude g/lbf
1
40m
23
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1 300m
Amplitude g/lbf
Amplitude g/lbf
3 2
20m
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
1
2
300m
Amplitude g/lbf
Amplitude g/lbf
3
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
1
300m
Amplitude g/lbf
Amplitude g/lbf
40m 32
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
15m
3 2
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m 1
2
3 300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
1
300m
Amplitude g/lbf
Amplitude g/lbf
40m 2
3
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
2 400m
15m
3
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 2 400m
60m
3
300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
40m 400m
2
30m 3 300m
Amplitude g/lbf
Amplitude g/lbf
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
300m
Amplitude g/lbf
Amplitude g/lbf
1
20m
2
3 200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m 1
2
3 300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
40m 400m
30m 2 300m
Amplitude g/lbf
Amplitude g/lbf
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1 300m
Amplitude g/lbf
Amplitude g/lbf
20m 2
3 200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
30m 300m
Amplitude g/lbf
Amplitude g/lbf
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m 1
300m
Amplitude g/lbf
Amplitude g/lbf
40m 2
3 200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1
300m
Amplitude g/lbf
Amplitude g/lbf
2
20m
3 200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
1
300m
Amplitude g/lbf
Amplitude g/lbf
2
40m 3
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
1
2 300m
Amplitude g/lbf
Amplitude g/lbf
40m 3
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1
300m
Amplitude g/lbf
Amplitude g/lbf
20m 2
200m
3
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
60m
300m
Amplitude g/lbf
Amplitude g/lbf
40m 2 3
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
Amplitude g/lbf
Amplitude g/lbf
100m
200m
12
3
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m 1
300m
Amplitude g/lbf
Amplitude g/lbf
20m
23
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
2 300m
Amplitude g/lbf
Amplitude g/lbf
3
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
1 300m
Amplitude g/lbf
Amplitude g/lbf
40m 2
3
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
30m
300m
Amplitude g/lbf
Amplitude g/lbf
2
20m 3
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m 2
3 300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
1
300m
Amplitude g/lbf
Amplitude g/lbf
2
40m 3
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1
300m
Amplitude g/lbf
Amplitude g/lbf
20m
2 200m
3
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
Amplitude g/lbf
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
1
300m
Amplitude g/lbf
Amplitude g/lbf
2
40m
3
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m 1
300m
Amplitude g/lbf
Amplitude g/lbf
20m 2
3 200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m 1
2
3 300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
40m 400m
1 2
30m 3 300m
Amplitude g/lbf
Amplitude g/lbf
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m 1
300m
Amplitude g/lbf
Amplitude g/lbf
20m
2
3 200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
30m 300m
Amplitude g/lbf
Amplitude g/lbf
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
30m
2
300m
Amplitude g/lbf
Amplitude g/lbf
3
20m
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m 1
300m
Amplitude g/lbf
Amplitude g/lbf
20m
2
3 200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
40m 3 400m
30m 300m
Amplitude g/lbf
Amplitude g/lbf
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
Amplitude g/lbf
Amplitude g/lbf
100m 1
2
200m
3
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
Amplitude g/lbf
Amplitude g/lbf
50m
200m
1
2
3 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1
2 400m
60m
3
300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
300m
Amplitude g/lbf
Amplitude g/lbf
1
40m
32
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1
300m
Amplitude g/lbf
Amplitude g/lbf
20m 2
3 200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1
400m
60m
2 3
300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
1
300m
Amplitude g/lbf
Amplitude g/lbf
40m 2
3
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1
300m
Amplitude g/lbf
Amplitude g/lbf
20m 23
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
60m
2 300m
Amplitude g/lbf
Amplitude g/lbf
3
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
30m 2
3 300m
Amplitude g/lbf
Amplitude g/lbf
20m
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
Enclosure 2
Collector End Series Loop Frequency Responses
(Amplitude versus Frequency)
GE Proprietary Information. This document contains proprietary information of the General Electric Company and
may not be used or disclosed to others, except with the written permission of General Electric Company. 8
400m
15m 21
300m
Amplitude g/lbf
Amplitude g/lbf
10m
3 200m
5m
100m
1 2 5 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
60m
2 300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
3
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
23 300m
Amplitude g/lbf
Amplitude g/lbf
20m
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 50 60 80 100 120 135
Frequency - Hz Frequency - Hz
1 400m
15m
2
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
3
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m 1
300m
Amplitude g/lbf
Amplitude g/lbf
40m 2
200m
3
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
3 400m
30m
300m
Amplitude g/lbf
Amplitude g/lbf
20m
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m 1
2
300m
Amplitude g/lbf
Amplitude g/lbf
10m
3 200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
2
300m
Amplitude g/lbf
Amplitude g/lbf
20m 3
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
32
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
40m 400m
30m 300m
Amplitude g/lbf
Amplitude g/lbf
20m 200m
21
3
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1
300m
Amplitude g/lbf
Amplitude g/lbf
20m 2
3 200m
10m
100m
1 2 3
0 0
0 50 100 150 200 50 60 80 100 120 135
Frequency - Hz Frequency - Hz
400m
30m
300m
Amplitude g/lbf
Amplitude g/lbf
20m 2
3 200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
1
2 300m
Amplitude g/lbf
Amplitude g/lbf
10m
3
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1
300m
Amplitude g/lbf
Amplitude g/lbf
2
20m
3 200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
300m
Amplitude g/lbf
Amplitude g/lbf
20m 23
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
1 300m
2
Amplitude g/lbf
Amplitude g/lbf
10m 3
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
30m
2 300m
Amplitude g/lbf
Amplitude g/lbf
20m
3 200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
1 300m
Amplitude g/lbf
Amplitude g/lbf
10m 32
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1
400m
30m
2
300m
Amplitude g/lbf
Amplitude g/lbf
20m
3 200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m 1
2
3 300m
Amplitude g/lbf
Amplitude g/lbf
20m
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m
Amplitude g/lbf
Amplitude g/lbf
20m
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
21
300m
Amplitude g/lbf
Amplitude g/lbf
3
20m
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1
23 300m
Amplitude g/lbf
Amplitude g/lbf
20m
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m
Amplitude g/lbf
Amplitude g/lbf
2
40m
3
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
32 300m
Amplitude g/lbf
Amplitude g/lbf
20m
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
32
400m
30m
300m
Amplitude g/lbf
Amplitude g/lbf
20m
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
2
3 300m
Amplitude g/lbf
Amplitude g/lbf
50m
200m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m
Amplitude g/lbf
Amplitude g/lbf
20m
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
300m
Amplitude g/lbf
Amplitude g/lbf
1
20m
3 2
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
300m
Amplitude g/lbf
Amplitude g/lbf
2
40m 3
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m
Amplitude g/lbf
Amplitude g/lbf
10m 3
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
15m
2 300m
Amplitude g/lbf
Amplitude g/lbf
10m 3
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
2 300m
Amplitude g/lbf
Amplitude g/lbf
20m 3
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
21
400m
15m
3
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1
2 400m
15m 3
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m 123
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1 300m
Amplitude g/lbf
Amplitude g/lbf
20m
2 3 200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
12
3
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1
400m
15m
32
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
3 400m
15m
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
2 300m
Amplitude g/lbf
Amplitude g/lbf
20m 3
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1 300m
Amplitude g/lbf
Amplitude g/lbf
20m 23
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
300m
Amplitude g/lbf
Amplitude g/lbf
23
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1
2 300m
Amplitude g/lbf
Amplitude g/lbf
3
20m
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m 1
2 300m
Amplitude g/lbf
Amplitude g/lbf
20m 3
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
Amplitude g/lbf
Amplitude g/lbf
100m
23 200m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1
2 300m
Amplitude g/lbf
Amplitude g/lbf
20m 3
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
2
300m
Amplitude g/lbf
Amplitude g/lbf
10m 3
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
2 400m
30m
3 300m
Amplitude g/lbf
Amplitude g/lbf
20m
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1 300m
Amplitude g/lbf
Amplitude g/lbf
20m
2
3 200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
8m 400m
6m 300m
Amplitude g/lbf
Amplitude g/lbf
4m 200m
2m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1
2 300m
Amplitude g/lbf
Amplitude g/lbf
20m
3
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
1
300m
Amplitude g/lbf
Amplitude g/lbf
2
10m 3
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
8m 2 400m
3
6m 300m
Amplitude g/lbf
Amplitude g/lbf
4m 200m
2m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
300m
Amplitude g/lbf
Amplitude g/lbf
20m
1 2 200m
3
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
123
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
8m 400m
2 3
6m 300m
Amplitude g/lbf
Amplitude g/lbf
4m 200m
2m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 2 400m
15m
3
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
300m
Amplitude g/lbf
Amplitude g/lbf
10m
1 3 2 200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
8m 400m
2
3
6m 300m
Amplitude g/lbf
Amplitude g/lbf
4m 200m
2m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 2 400m
15m
3
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
15m
3 2 300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
8m 400m
2
3
6m 300m
Amplitude g/lbf
Amplitude g/lbf
4m 200m
2m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
300m
Amplitude g/lbf
Amplitude g/lbf
1
10m 3
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
6m 300m
Amplitude g/lbf
Amplitude g/lbf
4m 200m
2m 100m
1 2 3 4
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m 3
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
300m
Amplitude g/lbf
Amplitude g/lbf
1
10m
2
3 200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m 1
32
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
1
300m
Amplitude g/lbf
Amplitude g/lbf
2 3
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1
32 400m
30m
300m
Amplitude g/lbf
Amplitude g/lbf
20m
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
300m
Amplitude g/lbf
Amplitude g/lbf
200m
200m
100m
100m
1
3 2
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
6m
300m
Amplitude g/lbf
Amplitude g/lbf
4m
200m
2m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
Amplitude g/lbf
Amplitude g/lbf
100m
200m
100m
32
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
300m
Amplitude g/lbf
Amplitude g/lbf
20m
200m
10m 31 2
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
8m 2 400m
3
6m 300m
Amplitude g/lbf
Amplitude g/lbf
4m 200m
2m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
3 2
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
6m 300m
Amplitude g/lbf
Amplitude g/lbf
4m 200m
2m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
8m 2 3 400m
6m 300m
Amplitude g/lbf
Amplitude g/lbf
4m 200m
2m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
15m 2
3
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1
8m 3 2 400m
6m 300m
Amplitude g/lbf
Amplitude g/lbf
4m 200m
2m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
6m 300m
Amplitude g/lbf
Amplitude g/lbf
4m 200m
2m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
4m 12 400m
3
3m 300m
Amplitude g/lbf
Amplitude g/lbf
2m 200m
1m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
6m 300m
Amplitude g/lbf
Amplitude g/lbf
4m 200m
2m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
2
3 400m
6m
300m
Amplitude g/lbf
Amplitude g/lbf
4m
200m
2m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
8m 2 400m
3
6m 300m
Amplitude g/lbf
Amplitude g/lbf
4m 200m
2m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
2 3
400m
6m
300m
Amplitude g/lbf
Amplitude g/lbf
4m
200m
2m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
2
8m 3 400m
6m 300m
Amplitude g/lbf
Amplitude g/lbf
4m 200m
2m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
8m 2 400m
3
6m 300m
Amplitude g/lbf
Amplitude g/lbf
4m 200m
2m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
Amplitude g/lbf
Amplitude g/lbf
100m
200m
100m
1 2 3
1 2 3
0 0
0 50 100 150 200 50 60 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
15m
2
3 300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3 4
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
1
300m
Amplitude g/lbf
Amplitude g/lbf
3 2
10m
200m
5m
100m
1 2 3 4
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
1 2 300m
3
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
300m
Amplitude g/lbf
Amplitude g/lbf
20m
1 2 200m
10m
100m
1 2 3 4
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
2 1
3 300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3 4
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m 1
300m
Amplitude g/lbf
Amplitude g/lbf
10m
2
3 200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1 300m
Amplitude g/lbf
Amplitude g/lbf
20m 2
3
200m
10m
100m
1 2 3 4
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1 300m
2
Amplitude g/lbf
Amplitude g/lbf
20m
3 200m
10m
100m
1 2 3 4
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
1 300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
2 3
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
40m 400m
30m 300m
Amplitude g/lbf
Amplitude g/lbf
1
20m 2 200m
3
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m
Amplitude g/lbf
Amplitude g/lbf
3
4m
200m
2m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
8m 400m
6m 3 2 300m
Amplitude g/lbf
Amplitude g/lbf
4m 200m
2m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1 300m
Amplitude g/lbf
Amplitude g/lbf
20m 2
3 200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
6m 3 2
300m
Amplitude g/lbf
Amplitude g/lbf
4m
200m
2m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
3 2 400m
6m
300m
Amplitude g/lbf
Amplitude g/lbf
4m
200m
2m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1 300m
Amplitude g/lbf
Amplitude g/lbf
20m 2
3
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
6m 300m
Amplitude g/lbf
Amplitude g/lbf
4m 200m
2m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
6m 300m
Amplitude g/lbf
Amplitude g/lbf
4m 200m
2m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
300m
Amplitude g/lbf
Amplitude g/lbf
10m 1
2
3 200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
21 300m
Amplitude g/lbf
Amplitude g/lbf
3
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
300m
Amplitude g/lbf
Amplitude g/lbf
20m
2 31 200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
2
300m
Amplitude g/lbf
Amplitude g/lbf
10m 3
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
21
300m
Amplitude g/lbf
Amplitude g/lbf
3
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1
2 400m
15m 3
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
15m
2
3
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
300m
Amplitude g/lbf
Amplitude g/lbf
1
20m 2
3 200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
6m 2
3 300m
Amplitude g/lbf
Amplitude g/lbf
4m
200m
2m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
2 400m
3
15m
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
12 400m
30m
300m
Amplitude g/lbf
Amplitude g/lbf
20m 3
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
300m
Amplitude g/lbf
Amplitude g/lbf
2 1
20m 3
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
300m
Amplitude g/lbf
Amplitude g/lbf
1
20m 2
200m
3
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m 21
3
300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
300m
Amplitude g/lbf
Amplitude g/lbf
20m 1
2 3
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
1
32
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
30m 300m
Amplitude g/lbf
Amplitude g/lbf
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1 300m
Amplitude g/lbf
Amplitude g/lbf
20m 2
3 200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
1
300m
Amplitude g/lbf
Amplitude g/lbf
2
10m
3 200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1
2 300m
Amplitude g/lbf
Amplitude g/lbf
3
20m
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
12
300m
Amplitude g/lbf
Amplitude g/lbf
3
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
15m 2
3 300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1 300m
Amplitude g/lbf
Amplitude g/lbf
20m 2
3
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
300m
Amplitude g/lbf
Amplitude g/lbf
1
10m 3 2
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m
Amplitude g/lbf
Amplitude g/lbf
10m 3
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1 300m
Amplitude g/lbf
Amplitude g/lbf
20m 2
3
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
300m
Amplitude g/lbf
Amplitude g/lbf
32 1
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
3
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1 300m
Amplitude g/lbf
Amplitude g/lbf
20m 2
3 200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
1
2 300m
Amplitude g/lbf
Amplitude g/lbf
10m 3
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m 1
300m
Amplitude g/lbf
Amplitude g/lbf
2
10m 3
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
300m
Amplitude g/lbf
Amplitude g/lbf
1
20m 32
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
Amplitude g/lbf
4m 200m
2m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
1 300m
Amplitude g/lbf
Amplitude g/lbf
2 3
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
21 3
300m
Amplitude g/lbf
Amplitude g/lbf
20m
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
1 300m
Amplitude g/lbf
Amplitude g/lbf
10m 2
3 200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
1
3 2 300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
12
400m
30m
3
300m
Amplitude g/lbf
Amplitude g/lbf
20m
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
1
300m
Amplitude g/lbf
Amplitude g/lbf
2
10m 3
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
Enclosure 3
Collector End Phase Connection Frequency Response
(Amplitude versus Frequency)
GE Proprietary Information. This document contains proprietary information of the General Electric Company and
may not be used or disclosed to others, except with the written permission of General Electric Company. 9
400m
300m 12
300m 3
Amplitude g/lbf
Amplitude g/lbf
200m
200m
3
100m
100m
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
2 400m
600m
3
300m 3
Amplitude g/lbf
Amplitude g/lbf
400m
200m
200m 2
100m
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
600m
300m
Amplitude g/lbf
Amplitude g/lbf
400m 2
200m
2
200m
100m 1
3
3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m
Amplitude g/lbf
Amplitude g/lbf
100m
200m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
2
300m
Amplitude g/lbf
Amplitude g/lbf
3
100m
200m
100m 3
2
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
1
2
300m
Amplitude g/lbf
Amplitude g/lbf
200m 3
200m
3
100m
100m 2
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
1 300m
Amplitude g/lbf
Amplitude g/lbf
200m
2 200m
3
100m
100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
1.5
300m
Amplitude g/lbf
Amplitude g/lbf
1
1 3
200m
500m 1
2 2
3 100m
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
1.5
300m
Amplitude g/lbf
Amplitude g/lbf
1
200m
500m 3
3 2 100m
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
40m 2 400m
3
30m 300m
Amplitude g/lbf
Amplitude g/lbf
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
300m
Amplitude g/lbf
Amplitude g/lbf
200m
32 200m
1
100m 3
100m
2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
600m 1
1
300m
Amplitude g/lbf
Amplitude g/lbf
400m 2
3 2
200m
200m 3
100m
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m 400m
300m 300m
Amplitude g/lbf
Amplitude g/lbf
2
200m 3 200m
100m 100m
2 3
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
21 400m
600m
3
300m
Amplitude g/lbf
Amplitude g/lbf
400m
200m
200m 3
100m 1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
800m 400m
2
600m 300m
Amplitude g/lbf
Amplitude g/lbf
3
400m 200m
1
200m 100m 2
3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
600m
300m
Amplitude g/lbf
Amplitude g/lbf
400m
3 2 200m
200m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
1 300m
2
Amplitude g/lbf
Amplitude g/lbf
100m
3
200m
2
100m 1
3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
300m
Amplitude g/lbf
Amplitude g/lbf
200m 2
3
200m 3
100m
100m
1
2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m 1
2
300m
Amplitude g/lbf
Amplitude g/lbf
200m
3 200m
3
100m
100m
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
600m 3 300m
Amplitude g/lbf
Amplitude g/lbf
400m 200m 2
3
200m 100m
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
600m 1
300m 2
Amplitude g/lbf
Amplitude g/lbf
400m
2 200m
200m 3 3
100m
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
300m
Amplitude g/lbf
Amplitude g/lbf
1
200m 2
3
200m
100m
100m
1 3
2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m
Amplitude g/lbf
Amplitude g/lbf
100m 3
200m 1
100m
2
3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
300m
2
300m
Amplitude g/lbf
Amplitude g/lbf
3
200m
2
200m
100m
100m 1
3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
Amplitude g/lbf
200m
200m
3
100m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
32 400m
300m
2
300m
Amplitude g/lbf
Amplitude g/lbf
200m
200m
100m
100m 3
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
600m
300m
Amplitude g/lbf
Amplitude g/lbf
400m 2
3
200m
200m 2
100m 1
3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
Amplitude g/lbf
Amplitude g/lbf
1
100m 2
200m
3
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
12
300m
Amplitude g/lbf
Amplitude g/lbf
200m 3
200m
100m
100m 2
1
3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
Amplitude g/lbf
200m 200m 1 3
100m 100m
2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
1 300m
Amplitude g/lbf
Amplitude g/lbf
200m 2
3 200m
100m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
800m 400m
600m 300m
Amplitude g/lbf
Amplitude g/lbf
400m 2 200m
3 1
200m 100m 2
3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
600m
2
300m
Amplitude g/lbf
Amplitude g/lbf
400m
200m
200m
100m 1
3 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
2 3 1 300m
Amplitude g/lbf
Amplitude g/lbf
100m
200m
3
100m
2
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
1
2
3 300m
Amplitude g/lbf
Amplitude g/lbf
3
200m
200m
100m
100m 1
2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
1
300m
Amplitude g/lbf
Amplitude g/lbf
100m 2
3
200m
1
100m 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
1 300m
Amplitude g/lbf
Amplitude g/lbf
2
200m
200m
3
100m 3
100m
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
600m 2 1
300m
Amplitude g/lbf
Amplitude g/lbf
400m
200m
200m 2 3
3 100m
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
600m
1
32 300m
Amplitude g/lbf
Amplitude g/lbf
400m
200m
200m
100m 1 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
600m
12
300m
Amplitude g/lbf
Amplitude g/lbf
400m
200m
200m 3
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
12
3
300m
Amplitude g/lbf
Amplitude g/lbf
100m
200m
100m 2
1 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m 1
2
3 300m
Amplitude g/lbf
Amplitude g/lbf
200m
200m 3
100m
100m
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
1 300m
Amplitude g/lbf
Amplitude g/lbf
200m
200m 3
2
100m 3
100m
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
600m
2 300m
Amplitude g/lbf
Amplitude g/lbf
3
400m 1
200m
200m
100m 2
3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
600m
2
300m
Amplitude g/lbf
Amplitude g/lbf
3 1
400m
200m
200m 2
100m 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m
Amplitude g/lbf
Amplitude g/lbf
20m
200m
10m
100m
2
1 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
1
2
300m
Amplitude g/lbf
Amplitude g/lbf
3
100m
200m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m
Amplitude g/lbf
Amplitude g/lbf
2
400m 3
200m 2
200m
100m 1
3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
1 2 300m
Amplitude g/lbf
Amplitude g/lbf
200m
3 200m
100m 3
100m
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m 2
3 300m
Amplitude g/lbf
Amplitude g/lbf
200m
200m 3
100m
100m
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m 2 300m
Amplitude g/lbf
Amplitude g/lbf
200m 200m
100m 100m 3
2
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
3 2
300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1
400m
300m 2
3 300m
Amplitude g/lbf
Amplitude g/lbf
200m
200m
100m
100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
1 2 300m
Amplitude g/lbf
Amplitude g/lbf
3
200m
200m
100m 3
100m
2
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
1
300m
Amplitude g/lbf
Amplitude g/lbf
100m 2
3 200m
100m
1 2 5 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
600m
2
3 300m
Amplitude g/lbf
Amplitude g/lbf
400m
200m
2
200m 3
100m
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
600m
1
300m
Amplitude g/lbf
Amplitude g/lbf
400m
200m
200m 3 2 2
100m
3
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
32
300m
Amplitude g/lbf
Amplitude g/lbf
100m
200m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
12
3
300m
Amplitude g/lbf
Amplitude g/lbf
100m
200m
100m 1 2
3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
1 300m
Amplitude g/lbf
Amplitude g/lbf
200m 2
200m
3
3
100m
100m
2
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
3 2
400m
300m
Amplitude g/lbf
Amplitude g/lbf
50m
200m
100m 1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
2
400m
300m
3
300m
Amplitude g/lbf
Amplitude g/lbf
200m
200m
100m 2
100m 1
3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
3
300m 300m
Amplitude g/lbf
Amplitude g/lbf
200m 200m
100m 100m 1 3
2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
Amplitude g/lbf
Amplitude g/lbf
100m
200m
1 2
3
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
1
2
300m
Amplitude g/lbf
Amplitude g/lbf
3
200m
3 200m
1
100m
100m
2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m 3
300m
300m
Amplitude g/lbf
Amplitude g/lbf
200m 3
200m
100m
100m 1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1
400m
300m
300m
Amplitude g/lbf
Amplitude g/lbf
200m
2 200m
3
100m
100m
1 3
2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
600m
300m
Amplitude g/lbf
Amplitude g/lbf
400m 2
3
200m 1
200m
100m 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
600m
300m
Amplitude g/lbf
Amplitude g/lbf
400m
200m
2
200m 3
100m 1
2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m
Amplitude g/lbf
Amplitude g/lbf
3
50m
200m
100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
2 400m
300m
Amplitude g/lbf
Amplitude g/lbf
100m
3
200m
100m
3
1
2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
213 400m
300m
300m
Amplitude g/lbf
Amplitude g/lbf
200m
200m
100m
100m 3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
2 400m
3
300m
Amplitude g/lbf
Amplitude g/lbf
100m
200m
100m
2
1 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m 2
300m
Amplitude g/lbf
Amplitude g/lbf
200m
3 2
200m
100m
100m
1 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m 1
2
3
300m
Amplitude g/lbf
Amplitude g/lbf
200m
2
200m
100m
100m 3
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
20m
100m
1 2
3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
20m
100m
2 3
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m
Amplitude g/lbf
Amplitude g/lbf
100m
200m
100m 3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
300m
Amplitude g/lbf
Amplitude g/lbf
12
200m 3
200m
100m 3
100m
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
800m 400m
600m 300m
Amplitude g/lbf
Amplitude g/lbf
400m 2 200m
3
200m 100m 1
3
2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m 400m
2
300m 300m
Amplitude g/lbf
Amplitude g/lbf
3
200m 200m
2
100m 100m 3
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1 300m
Amplitude g/lbf
Amplitude g/lbf
20m 3 2
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
Amplitude g/lbf
100m
200m
100m
1 2
3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
600m 21
300m
Amplitude g/lbf
Amplitude g/lbf
400m
3 200m
200m
100m
2
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
300m
Amplitude g/lbf
Amplitude g/lbf
1
200m 2
3
200m
100m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
800m 400m
600m 300m
Amplitude g/lbf
Amplitude g/lbf
400m 2 200m
2
3
3
200m 100m
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
3
1 300m
Amplitude g/lbf
Amplitude g/lbf
2
200m
1 2
100m
3
23
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
300m
300m 3
Amplitude g/lbf
Amplitude g/lbf
200m
200m
2
100m 3
100m
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
1
300m
Amplitude g/lbf
Amplitude g/lbf
100m
200m
2
3
3 100m
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m 1
2 300m
Amplitude g/lbf
Amplitude g/lbf
200m 3
200m
100m
100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
3
300m
Amplitude g/lbf
Amplitude g/lbf
100m
200m
100m 3
2
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
1
300m
Amplitude g/lbf
Amplitude g/lbf
200m
200m
2
100m
100m 2
1 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
2
3 300m
Amplitude g/lbf
Amplitude g/lbf
100m
200m
3
100m
2
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
12 300m
Amplitude g/lbf
Amplitude g/lbf
3
100m
200m
100m
2 3
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
1
300m
Amplitude g/lbf
Amplitude g/lbf
200m 2
3 200m
100m
100m
2 3
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
32
400m
300m
Amplitude g/lbf
Amplitude g/lbf
100m
200m
2
100m
1
3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1
2 400m
3
300m
Amplitude g/lbf
Amplitude g/lbf
100m
200m
100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
600m 2 300m
Amplitude g/lbf
Amplitude g/lbf
400m 200m
3
200m 100m 1 2
3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
1.5
300m
Amplitude g/lbf
Amplitude g/lbf
1
200m
500m
100m
3 2 1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
1 300m
Amplitude g/lbf
Amplitude g/lbf
23
200m
200m
100m
100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
Amplitude g/lbf
200m
3
200m
100m
100m 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
600m 2 300m
Amplitude g/lbf
Amplitude g/lbf
3
400m 200m
200m 100m
2
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1
400m
300m
2
300m
Amplitude g/lbf
Amplitude g/lbf
3
200m
200m
100m
100m 1
3
2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
600m 300m
Amplitude g/lbf
Amplitude g/lbf
400m 200m
2
3
200m 100m 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
1.5
300m
Amplitude g/lbf
Amplitude g/lbf
1
2 200m
500m 1
3 100m 2
3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
600m
300m
Amplitude g/lbf
Amplitude g/lbf
400m
200m
23
200m
100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
1
2
3 300m
Amplitude g/lbf
Amplitude g/lbf
200m
200m
3
100m
100m
1
2
0 0
0 50 100 150 200 50 60 80 100 120 135
Frequency - Hz Frequency - Hz
400m
300m
300m
Amplitude g/lbf
Amplitude g/lbf
1
200m
32 200m
1
100m
100m
2
3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
Lowers leads blocks were inspected for dusting, loose blocking, broken ties. No signs of the
dusting, loose blocking, broken ties during this inspection.
It was striped the insulation from the Flexible leads , removed putty, completed a thorough
visual inspection of the flexible leads. It was not found any sign of improper assembly , hot
stops for looseness connection or cracks in the flexible lead. Even thought , Customer
required the replacement of the flexible leads for the new flexible leads design.
270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 1160 of 1653
GE Power Power Services
270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 1161 of 1653
GE Power Power Services
It was not finding any sign of cracks visually or by dye penetrant method.
270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 1162 of 1653
GE Power Power Services
B53 phase strap insulation removed B40 phase strap insulation removed
270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 1163 of 1653
GE Power Power Services
270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 1164 of 1653
164-01-21 -PT Estator junction phases
DENTIFICACIÓN:PC-20-01-014 Rev.1
REPORTE END INFORME
164-01-21 -PT
N°
INFORME POR LIQUIDOS PENETRANTES FECHA 3/02/2021
Testing Service Group S.A.C.
PAGINA 01 DE 04
CLIENTE: CONTRATISTA:
PROYECTO:
PARADA DE PLANTA CENTRAL
TERMICA CHILCA UNO - ENGIE FIELDCORE a GE Company TESTING SERVICE GROUP SAC
EVALUACION
DIMENSIONES
Identificacion del
Item
OBSERVACIONES :
1.- Se realizó la Inspección por medio de liquidos penetrantes a cuatro Phase straps
2.- Los Phase straps B15, B53, T62 no presentan indicaciones relevantes
3.- El Phase Straps B40, presentan dos indicaciones, por golpes
4.- Los BEND de los cuatro Phase Straps inspeccionados se encuentran libre de indicaciones
ELEMENTO B53
This blocking upgrade and modifications on the connection rings and phase straps provides
thermal compliance and resonant frequency isolation to the phase straps and backset on
324 generators.
The following inspection and modifications were made in accordance with the requirements
to compliance with the TIL 1965:
• Backset blocks removal: This unit didn't have backset blocks, so it was not necessary
the removal of this blocks.
• Removal of circumferential blocks between the series loop and phase straps: it was
removed the circumferential blocks between the series loop and phase joints from the 6
phase connections locations at 12 o'clock , 2 o'clock, 4 o'clock , 6 o' clock, 8 o'clock and
10 o'clock respectively.
• Added new radial blocks: I was added new radial blocks between top and bottom
phase straps on all 6 positions.
• Inertance/ bump test was performed before tie the radial blocks. Some phase straps on
tangential or axial position during inertance test to eliminate this high values and
compliance with the TIL it was required by engineer installation of an additional diagonal
blocks. Diagonal blocks were added on the following positions: 2oclock, 4o'clock, 6
o'clock and 10 o'clock.
• Selective connection ring block removal: In compliance with the rules mentioned in the
GE procedure it was removed 2 blocks that are in the picture attached on this report.
270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 1169 of 1653
GE Power Power Services
New blocking - 10 o'clock position New blocks after tying - 2 o'clock position
270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 1170 of 1653
GE Power Power Services
New blocks after tying - 10 o'clock position Ties with red eye and floodin resin applied -
10 o'clock position
Ties with red eye and floodin resin applied - Ties with red eye and floodin resin applied -
2 o'clock position 4 o'clock position
270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 1171 of 1653
GE Power Power Services
270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 1172 of 1653
GE Power Power Services
270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 1173 of 1653
Bump Test_As Left
GE Proprietary Information. This document contains proprietary information of the General Electric Company and
may not be used or disclosed to others, except with the written permission of General Electric Company. 1
EXECUTIVE SUMMARY
This report contains results from a modal impact (bump) test on the end winding series loops and
phase connections of unit ST1 a GE generator S/N 290T818 at the Chilca Uno site in Lima, Peru, on
February 10, 2021. An instrumented hammer was used to excite the generator components while an
accelerometer measured the response. Data was analyzed with a spectrum analyzer in real time and
the frequency response functions, in g/lb were obtained on both the turbine end (TE) and collector
end (CE) series loops and phase connections.
The collector end series Loop axial, radial, and tangential responses were acceptable and found within
limits. Plots of the data are shown in Enclosure 2 of Appendix B.
The collector end phase connection axial, radial, and tangential responses were acceptable and found
within limits. Plots of the data are shown in Enclosure 3 of Appendix B.
GE Proprietary Information. This document contains proprietary information of the General Electric Company and
may not be used or disclosed to others, except with the written permission of General Electric Company. 2
EQUIPMENT USED
PCB Model 338C04 Accelerometer, S/N 6045 and calibration due date 13AUG2021
PCB Model 086D20 Impact Hammer, S/N 20552 and calibration due date 13AUG2021
OROS OR34 4 Channel PC Based Spectrum Analyzer, S/N 901793 and calibration due date 12AUG2021
TEST OVERVIEW
An end winding vibration “bump” test is performed to determine the fundamental resonant frequency
and associated response value of the individual series loops and phase connections of a generator.
Data related to series loops and phase connections, which exceed current GE criteria, is relayed to GE
Generator Engineering where the results of these tests are analyzed to determine whether additional
support is required. Data related to series loops and phase connections, which appear around 60 and
120 Hz (or 50 and 100 Hz) will be relayed to site personnel for other OEM units.
TERMINOLOGY (SERIES LOOPS AND PHASE CONNECTIONS DATA PLOTS PER LOCATION)
(Appendix B Enclosures 1 through 3)
The left plot for each measurement location and direction is scaled with a frequency range of 0 to 200
Hz. The right plot is scaled for a range of 55 to 140 Hz and includes a horizontal amplitude line
identifying the engineering pass/fail threshold. At the upper left of each trace is a file name identifying
the measurement location and direction. The terminology used for Series Loops and Phase Connection
Data Plots per location is the following:
CEPCBT001.UFF
| | | | | --------------- Bar Number (1 to 72)
| | | | ----------------- A = Axial Direction, R = Radial Direction, T = Tangential Direction
| | | ------------------- B = Bottom Phase Connection; T = Top Phase Connection
| | ---------------------- PC = Phase Connection (No designation for Series Loops)
|-------------------------- CE = Collector End; TE = Turbine End
GE Proprietary Information. This document contains proprietary information of the General Electric Company and
may not be used or disclosed to others, except with the written permission of General Electric Company. 3
APPENDIX A
Acceptance Criteria
(Test data was compared to the amplitude threshold criteria outlined in table 1)
GE Proprietary Information. This document contains proprietary information of the General Electric Company and
may not be used or disclosed to others, except with the written permission of General Electric Company. 4
Table 1: Acceptance criteria for GE conventionally-cooled 324 generator resonance testing (2 pole,
60 HZ), Repair Engineering Instruction 503HA422 – 324 End Winding Blocking Upgrades
Series Loop
Measurement Phase Connection Applicable Frequency
Direction Threshold Threshold Range
Axial 0.5 g / lb 0.5 g / lb 55-70 Hz & 110-140 Hz
Radial 0.5 g / lb 0.5 g/ lb 55-70 Hz & 110-140 Hz
Tangential 0.5 g / lb 0.5 g / lb 55-70 Hz & 110-140 Hz
GE Proprietary Information. This document contains proprietary information of the General Electric Company and
may not be used or disclosed to others, except with the written permission of General Electric Company. 5
APPENDIX B
Test Data Plots
(Amplitude versus Frequency)
GE Proprietary Information. This document contains proprietary information of the General Electric Company and
may not be used or disclosed to others, except with the written permission of General Electric Company. 6
Enclosure 1
Turbine End Series Loop Frequency Responses
(Amplitude versus Frequency)
GE Proprietary Information. This document contains proprietary information of the General Electric Company and
may not be used or disclosed to others, except with the written permission of General Electric Company. 7
400m
30m
1
300m
Amplitude g/lbf
Amplitude g/lbf
20m 23
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
30m 3 300m
Amplitude g/lbf
Amplitude g/lbf
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
1
300m
Amplitude g/lbf
Amplitude g/lbf
40m
2
3 200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1
400m
30m
2 300m
Amplitude g/lbf
Amplitude g/lbf
20m 3
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
2
40m 3 400m
30m 300m
Amplitude g/lbf
Amplitude g/lbf
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
1
300m
Amplitude g/lbf
Amplitude g/lbf
40m
32 200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
30m
300m
Amplitude g/lbf
Amplitude g/lbf
20m 23
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
40m 400m
3
30m 300m
Amplitude g/lbf
Amplitude g/lbf
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
Amplitude g/lbf
Amplitude g/lbf
100m
1 200m
32
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1
400m
30m
300m
Amplitude g/lbf
Amplitude g/lbf
2
20m
3 200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
60m
2
300m
Amplitude g/lbf
Amplitude g/lbf
40m 3
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
300m
Amplitude g/lbf
Amplitude g/lbf
1
40m
23 200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
30m
300m
Amplitude g/lbf
Amplitude g/lbf
2
20m
200m
3
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
1
300m
Amplitude g/lbf
Amplitude g/lbf
40m 2 3
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
1 300m
Amplitude g/lbf
Amplitude g/lbf
40m
2 200m
3
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
Amplitude g/lbf
20m 3
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
1
300m
Amplitude g/lbf
Amplitude g/lbf
2
40m 3
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
Amplitude g/lbf
Amplitude g/lbf
100m
1
200m
2
3
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
30m 2
300m
Amplitude g/lbf
Amplitude g/lbf
20m
3 200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
60m 2
300m
Amplitude g/lbf
Amplitude g/lbf
3
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
Amplitude g/lbf
Amplitude g/lbf
100m
1
200m
2
3
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m 1 2
300m
Amplitude g/lbf
Amplitude g/lbf
20m
3 200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1
400m
60m
2
3
300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
1 2
300m
Amplitude g/lbf
Amplitude g/lbf
40m 3
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m 2 1
300m
Amplitude g/lbf
Amplitude g/lbf
20m
3
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m 1
2 3
300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
12
300m
Amplitude g/lbf
Amplitude g/lbf
40m 3
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
300m
Amplitude g/lbf
Amplitude g/lbf
1
20m
2
200m
3
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
30m 300m
Amplitude g/lbf
Amplitude g/lbf
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
300m
Amplitude g/lbf
Amplitude g/lbf
40m 23
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
2 400m
15m
3 300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
40m 400m
2
3
30m 300m
Amplitude g/lbf
Amplitude g/lbf
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
40m 400m
30m 300m
Amplitude g/lbf
Amplitude g/lbf
23
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
300m
Amplitude g/lbf
Amplitude g/lbf
1
20m
2
3 200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
3 400m
30m
300m
Amplitude g/lbf
Amplitude g/lbf
20m
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
2
300m
Amplitude g/lbf
Amplitude g/lbf
50m
3
200m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
300m
Amplitude g/lbf
Amplitude g/lbf
1
20m 2
3
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1
40m 2 400m
3
30m 300m
Amplitude g/lbf
Amplitude g/lbf
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1
2
300m
Amplitude g/lbf
Amplitude g/lbf
20m 3
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
300m
Amplitude g/lbf
Amplitude g/lbf
1 2
20m 3
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m
Amplitude g/lbf
Amplitude g/lbf
20m
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
300m
Amplitude g/lbf
Amplitude g/lbf
40m 1
2
200m
3
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1 300m
Amplitude g/lbf
Amplitude g/lbf
2 3
20m
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
40m 400m
2
3
30m 300m
Amplitude g/lbf
Amplitude g/lbf
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
1 300m
Amplitude g/lbf
Amplitude g/lbf
40m 2
3 200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1 2 300m
Amplitude g/lbf
Amplitude g/lbf
3
20m
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
1
300m
Amplitude g/lbf
Amplitude g/lbf
40m 2 3
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
40m 400m
1
2
30m 300m
Amplitude g/lbf
Amplitude g/lbf
3
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1 300m
Amplitude g/lbf
Amplitude g/lbf
20m 2
3 200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
1
300m
Amplitude g/lbf
Amplitude g/lbf
40m 2
3
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m 1
300m
Amplitude g/lbf
Amplitude g/lbf
40m
23 200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1
300m
Amplitude g/lbf
Amplitude g/lbf
2
20m
3
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
40m 400m
3 2
30m 300m
Amplitude g/lbf
Amplitude g/lbf
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
1
2
300m
Amplitude g/lbf
Amplitude g/lbf
40m
3 200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1
300m
Amplitude g/lbf
Amplitude g/lbf
20m 2
200m
3
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
60m
2
300m
Amplitude g/lbf
Amplitude g/lbf
3
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m
Amplitude g/lbf
Amplitude g/lbf
50m
3 200m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m 1
300m
Amplitude g/lbf
Amplitude g/lbf
20m 2
3
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
60m 2
3
300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
21
300m
Amplitude g/lbf
Amplitude g/lbf
100m
200m
3
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1
300m
Amplitude g/lbf
Amplitude g/lbf
20m 2
3 200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m 1
2 3
300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
1 300m
Amplitude g/lbf
Amplitude g/lbf
100m
200m
32
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1 300m
Amplitude g/lbf
Amplitude g/lbf
2
20m
3 200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
60m
2 300m
Amplitude g/lbf
Amplitude g/lbf
3
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
1
2 300m
Amplitude g/lbf
Amplitude g/lbf
100m
200m
3
100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1
300m
Amplitude g/lbf
Amplitude g/lbf
20m
2
3
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
60m
3 2
300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m
Amplitude g/lbf
Amplitude g/lbf
50m
3
200m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1 300m
Amplitude g/lbf
Amplitude g/lbf
20m
32 200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m 2 1
300m
Amplitude g/lbf
Amplitude g/lbf
3
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1
2 400m
60m
300m
Amplitude g/lbf
Amplitude g/lbf
40m
3
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
300m
Amplitude g/lbf
Amplitude g/lbf
1
20m
2
3 200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
1
300m
Amplitude g/lbf
Amplitude g/lbf
40m 2
3
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
1
300m
Amplitude g/lbf
Amplitude g/lbf
2
40m
3 200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m 1
2
300m
Amplitude g/lbf
Amplitude g/lbf
3
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m
Amplitude g/lbf
Amplitude g/lbf
50m 2
3 200m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1
3 2 300m
Amplitude g/lbf
Amplitude g/lbf
20m
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
1
300m
Amplitude g/lbf
Amplitude g/lbf
40m 2 3
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m 1
300m
Amplitude g/lbf
Amplitude g/lbf
200m
200m
23
100m
100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1 300m
Amplitude g/lbf
Amplitude g/lbf
20m 2
3 200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m
Amplitude g/lbf
Amplitude g/lbf
3
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
1
300m
Amplitude g/lbf
Amplitude g/lbf
50m
23
200m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
300m
Amplitude g/lbf
Amplitude g/lbf
1
20m 2
200m
3
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
60m
2
300m
Amplitude g/lbf
Amplitude g/lbf
3
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m
Amplitude g/lbf
Amplitude g/lbf
3
50m
200m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1 300m
Amplitude g/lbf
Amplitude g/lbf
20m
2 200m
3
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
1
300m
Amplitude g/lbf
Amplitude g/lbf
2
40m 3
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
3 300m
Amplitude g/lbf
Amplitude g/lbf
50m
200m
100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1 300m
Amplitude g/lbf
Amplitude g/lbf
2
20m
200m
3
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
300m
Amplitude g/lbf
Amplitude g/lbf
1 2
40m 3
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
2
400m
30m
3
300m
Amplitude g/lbf
Amplitude g/lbf
20m
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
30m
2 300m
Amplitude g/lbf
Amplitude g/lbf
20m
3
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
2
40m 400m
3
30m 300m
Amplitude g/lbf
Amplitude g/lbf
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
300m
Amplitude g/lbf
Amplitude g/lbf
40m 2
3
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1
2 300m
Amplitude g/lbf
Amplitude g/lbf
20m
200m
3
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m 1
2 300m
Amplitude g/lbf
Amplitude g/lbf
40m 3
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1
400m
300m
Amplitude g/lbf
Amplitude g/lbf
50m 23
200m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1
300m
Amplitude g/lbf
Amplitude g/lbf
20m 2
200m
3
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
60m
2
300m
Amplitude g/lbf
Amplitude g/lbf
40m 3
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
300m
Amplitude g/lbf
Amplitude g/lbf
2
20m 3
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1
300m
Amplitude g/lbf
Amplitude g/lbf
20m
2 200m
3
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
60m
2 300m
Amplitude g/lbf
Amplitude g/lbf
40m 3
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
21 400m
60m
300m
Amplitude g/lbf
Amplitude g/lbf
3
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1
300m
Amplitude g/lbf
Amplitude g/lbf
20m 2
200m
3
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
300m
Amplitude g/lbf
Amplitude g/lbf
200m
200m
100m
1 100m
2 3
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
60m
32 300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1
300m
Amplitude g/lbf
Amplitude g/lbf
2
20m
200m
3
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
40m 400m
30m 300m
Amplitude g/lbf
Amplitude g/lbf
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1
400m
60m
2
3 300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1 300m
Amplitude g/lbf
Amplitude g/lbf
20m 2
200m
3
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
Amplitude g/lbf
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
300m
Amplitude g/lbf
Amplitude g/lbf
1
40m
2
3 200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
40m 400m
30m 300m
Amplitude g/lbf
Amplitude g/lbf
20m 1 200m
2
3
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
60m 2
3
300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
40m 400m
30m 300m
Amplitude g/lbf
Amplitude g/lbf
23
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
Amplitude g/lbf
Amplitude g/lbf
50m
200m
100m
2 3 1
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
1
2
3 300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m 1
300m
Amplitude g/lbf
Amplitude g/lbf
40m
32
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
15m
2
300m
Amplitude g/lbf
Amplitude g/lbf
10m 3
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
1
3 2
300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
2 400m
30m
3 300m
Amplitude g/lbf
Amplitude g/lbf
20m
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
Amplitude g/lbf
10m 3
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
30m 300m
Amplitude g/lbf
Amplitude g/lbf
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
300m
Amplitude g/lbf
Amplitude g/lbf
40m
12 200m
3
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
2 400m
15m
3
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1
40m 400m
2 3
30m 300m
Amplitude g/lbf
Amplitude g/lbf
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
30m 3 300m
Amplitude g/lbf
Amplitude g/lbf
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
2 1
300m
Amplitude g/lbf
Amplitude g/lbf
3
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m
Amplitude g/lbf
Amplitude g/lbf
20m
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1 300m
Amplitude g/lbf
Amplitude g/lbf
20m
23 200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
15m 3 2
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
30m 300m
Amplitude g/lbf
Amplitude g/lbf
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
1 300m
Amplitude g/lbf
Amplitude g/lbf
40m
2 200m
3
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
15m 23
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
Amplitude g/lbf
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
2 3
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
20m 1
23 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
30m 300m
Amplitude g/lbf
Amplitude g/lbf
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
Amplitude g/lbf
Amplitude g/lbf
100m
200m
100m
3 2 1
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
2 300m
Amplitude g/lbf
Amplitude g/lbf
3
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
300m
Amplitude g/lbf
Amplitude g/lbf
20m
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1 300m
Amplitude g/lbf
Amplitude g/lbf
20m
3 2 200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
300m
Amplitude g/lbf
Amplitude g/lbf
1
20m
2 200m
3
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
3 2 400m
30m
300m
Amplitude g/lbf
Amplitude g/lbf
20m
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
40m 400m
30m 300m
Amplitude g/lbf
Amplitude g/lbf
20m 32 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
1
20m
32 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m
Amplitude g/lbf
Amplitude g/lbf
20m
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
3 21 300m
Amplitude g/lbf
Amplitude g/lbf
20m
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1
400m
15m 2
300m
Amplitude g/lbf
Amplitude g/lbf
3
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
40m 400m
3 2
30m 300m
Amplitude g/lbf
Amplitude g/lbf
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
12
3
300m
Amplitude g/lbf
Amplitude g/lbf
20m
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
300m
Amplitude g/lbf
Amplitude g/lbf
1
20m
2
200m
3
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
40m 400m
2
30m 3 300m
Amplitude g/lbf
Amplitude g/lbf
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
40m 1 400m
2
30m 300m
Amplitude g/lbf
3
Amplitude g/lbf
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
2
300m
Amplitude g/lbf
Amplitude g/lbf
3
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
40m 400m
2
30m 300m
Amplitude g/lbf
Amplitude g/lbf
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1
40m 400m
2
30m 3 300m
Amplitude g/lbf
Amplitude g/lbf
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m 2
3
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
30m 3 300m
Amplitude g/lbf
Amplitude g/lbf
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1
300m
Amplitude g/lbf
Amplitude g/lbf
20m 32
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
1
2 3 300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
40m 2 400m
3
30m 300m
Amplitude g/lbf
Amplitude g/lbf
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
Amplitude g/lbf
20m
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
15m 2
3
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
1
300m
Amplitude g/lbf
Amplitude g/lbf
2
40m 3
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
32 300m
Amplitude g/lbf
Amplitude g/lbf
20m
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
40m 400m
3
30m 300m
Amplitude g/lbf
Amplitude g/lbf
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m
Amplitude g/lbf
Amplitude g/lbf
20m
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
2 400m
15m 3
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m 1
2
300m
Amplitude g/lbf
Amplitude g/lbf
3
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1
300m
Amplitude g/lbf
Amplitude g/lbf
20m 2
3 200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
23
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
1
3 2
300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1
300m
Amplitude g/lbf
Amplitude g/lbf
20m 2
3 200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
3 2 400m
15m
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
30m 300m
Amplitude g/lbf
Amplitude g/lbf
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m
Amplitude g/lbf
Amplitude g/lbf
2
20m 3
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
300m
Amplitude g/lbf
Amplitude g/lbf
1
20m 2
200m
3
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
300m
Amplitude g/lbf
Amplitude g/lbf
20m
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
30m
2
3 300m
Amplitude g/lbf
Amplitude g/lbf
20m
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1 300m
Amplitude g/lbf
Amplitude g/lbf
2
20m
200m
3
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
40m 400m
3 2
30m 300m
Amplitude g/lbf
Amplitude g/lbf
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
300m
Amplitude g/lbf
Amplitude g/lbf
1
40m
2 200m
3
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1
300m
Amplitude g/lbf
Amplitude g/lbf
20m 2
200m
3
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
60m
300m
Amplitude g/lbf
Amplitude g/lbf
40m 2
3
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
40m 400m
30m 300m
Amplitude g/lbf
Amplitude g/lbf
2
20m 3 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1
300m
Amplitude g/lbf
Amplitude g/lbf
20m
2
3 200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
2
300m
Amplitude g/lbf
Amplitude g/lbf
3
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
300m
Amplitude g/lbf
Amplitude g/lbf
1
40m 2
3 200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
30m
300m
Amplitude g/lbf
Amplitude g/lbf
2
20m 3
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m 2
300m
Amplitude g/lbf
Amplitude g/lbf
3
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1
40m 400m
2
3
30m 300m
Amplitude g/lbf
Amplitude g/lbf
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1
300m
Amplitude g/lbf
Amplitude g/lbf
20m
3 2 200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m
Amplitude g/lbf
3
Amplitude g/lbf
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1
300m
Amplitude g/lbf
Amplitude g/lbf
23
20m
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1
300m
Amplitude g/lbf
Amplitude g/lbf
20m 2
3 200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
1 2
300m
Amplitude g/lbf
Amplitude g/lbf
3
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
40m 2 400m
3
30m 300m
Amplitude g/lbf
Amplitude g/lbf
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1
300m
Amplitude g/lbf
Amplitude g/lbf
20m
2 3
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
300m
Amplitude g/lbf
Amplitude g/lbf
2 1
3
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m 1
2
300m
Amplitude g/lbf
Amplitude g/lbf
3
20m
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1
300m
Amplitude g/lbf
Amplitude g/lbf
20m 2 3
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
Amplitude g/lbf
Amplitude g/lbf
1
50m 2
3
200m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
Amplitude g/lbf
Amplitude g/lbf
100m 12
200m
3
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1
300m
Amplitude g/lbf
Amplitude g/lbf
20m 2
200m
3
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
60m
2
3 300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
40m 400m
1
2
30m 300m
Amplitude g/lbf
3
Amplitude g/lbf
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1
300m
Amplitude g/lbf
Amplitude g/lbf
20m
2
200m
3
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
60m
2 3
300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
40m 400m
1
30m 300m
Amplitude g/lbf
Amplitude g/lbf
2
3
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1
300m
Amplitude g/lbf
Amplitude g/lbf
20m
23
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m 1
300m
Amplitude g/lbf
Amplitude g/lbf
3 2
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
2
3 300m
Amplitude g/lbf
Amplitude g/lbf
20m
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
Enclosure 2
Collector End Series Loop Frequency Responses
(Amplitude versus Frequency)
GE Proprietary Information. This document contains proprietary information of the General Electric Company and
may not be used or disclosed to others, except with the written permission of General Electric Company. 8
400m
15m
2 300m
Amplitude g/lbf
Amplitude g/lbf
3
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m
Amplitude g/lbf
Amplitude g/lbf
100m
32 200m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
Amplitude g/lbf
20m
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
1
300m
Amplitude g/lbf
Amplitude g/lbf
10m
3 200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
1
300m
Amplitude g/lbf
Amplitude g/lbf
100m
200m
3 2
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
2 300m
Amplitude g/lbf
Amplitude g/lbf
20m 3
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
300m
Amplitude g/lbf
Amplitude g/lbf
10m
2 200m
3
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
60m
300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
20m 32
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1
2 300m
Amplitude g/lbf
Amplitude g/lbf
3
20m
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m 2
3
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1
300m
Amplitude g/lbf
Amplitude g/lbf
20m 2
3
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 32 400m
15m
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
300m
Amplitude g/lbf
Amplitude g/lbf
2 3
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
300m
Amplitude g/lbf
Amplitude g/lbf
1
20m
3 2
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
15m
3 2
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
2 300m
Amplitude g/lbf
Amplitude g/lbf
10m 3
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1 300m
Amplitude g/lbf
Amplitude g/lbf
2
20m 3
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
300m
Amplitude g/lbf
Amplitude g/lbf
20m
1
23 200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
1
2 300m
Amplitude g/lbf
Amplitude g/lbf
10m
3
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1 23 300m
Amplitude g/lbf
Amplitude g/lbf
20m
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m 1
23
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1
400m
15m 2 3
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
60m
300m
Amplitude g/lbf
Amplitude g/lbf
40m
23 200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1
300m
Amplitude g/lbf
Amplitude g/lbf
2
20m
3
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
Amplitude g/lbf
Amplitude g/lbf
1
100m
200m
3 2
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
30m
300m
Amplitude g/lbf
Amplitude g/lbf
20m 3
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
2
30m 300m
Amplitude g/lbf
Amplitude g/lbf
3
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
21 400m
300m
Amplitude g/lbf
Amplitude g/lbf
100m
200m
3
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
1
2 300m
Amplitude g/lbf
Amplitude g/lbf
40m
3 200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1
300m
Amplitude g/lbf
Amplitude g/lbf
20m
2
3 200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
3
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
15m
2
3 300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
23 300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
30m 300m
Amplitude g/lbf
Amplitude g/lbf
3
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
15m
300m
Amplitude g/lbf
3
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
1
300m
Amplitude g/lbf
Amplitude g/lbf
2
10m 3
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
15m
2
300m
Amplitude g/lbf
Amplitude g/lbf
3
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
300m
Amplitude g/lbf
Amplitude g/lbf
20m
200m
10m 31 2
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1
300m
Amplitude g/lbf
Amplitude g/lbf
20m 2 3
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
300m
Amplitude g/lbf
Amplitude g/lbf
10m
1
3 2 200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1
300m
Amplitude g/lbf
Amplitude g/lbf
20m 2 3
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
40m 400m
30m 300m
Amplitude g/lbf
Amplitude g/lbf
20m 200m
1
10m 3 2 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
30m
3 2
300m
Amplitude g/lbf
Amplitude g/lbf
20m
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1
2 300m
Amplitude g/lbf
Amplitude g/lbf
20m 3
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
1
2 300m
Amplitude g/lbf
Amplitude g/lbf
10m 3
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1 2 300m
Amplitude g/lbf
Amplitude g/lbf
20m
3 200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
1
2
300m
Amplitude g/lbf
Amplitude g/lbf
100m
200m
3 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m 1
300m
Amplitude g/lbf
Amplitude g/lbf
40m 3
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
21
300m
Amplitude g/lbf
Amplitude g/lbf
3
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
Amplitude g/lbf
Amplitude g/lbf
100m
200m
1 100m
3 2
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
300m
Amplitude g/lbf
Amplitude g/lbf
20m 1 2
3 200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
6m 300m
Amplitude g/lbf
Amplitude g/lbf
4m 200m
2m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
Amplitude g/lbf
Amplitude g/lbf
100m
200m
100m
2 1 3
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
300m
Amplitude g/lbf
Amplitude g/lbf
20m 2
3 200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
3
6m 300m
Amplitude g/lbf
Amplitude g/lbf
4m 200m
2m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
2 1
20m
3 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
300m
Amplitude g/lbf
Amplitude g/lbf
20m
2 200m
3
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
8m 2 400m
3
6m 300m
Amplitude g/lbf
Amplitude g/lbf
4m 200m
2m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1 300m
Amplitude g/lbf
2
Amplitude g/lbf
20m
3
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
300m
Amplitude g/lbf
Amplitude g/lbf
20m
200m
10m 3 21
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
300m
Amplitude g/lbf
Amplitude g/lbf
10m
21
3 200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1
300m
Amplitude g/lbf
Amplitude g/lbf
2
20m
3
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m 1
2 300m
Amplitude g/lbf
Amplitude g/lbf
10m 3
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
300m
Amplitude g/lbf
Amplitude g/lbf
10m
2 1
3 200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1 300m
Amplitude g/lbf
Amplitude g/lbf
2
20m 3
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
1 300m
Amplitude g/lbf
Amplitude g/lbf
2
10m
3
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m
Amplitude g/lbf
Amplitude g/lbf
4m
200m
2m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
300m
Amplitude g/lbf
1
Amplitude g/lbf
2
20m
3
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
40m 400m
30m 300m
Amplitude g/lbf
Amplitude g/lbf
20m 200m
2 3
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
20m
100m
12
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
2 13
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
40m 400m
30m 300m
Amplitude g/lbf
Amplitude g/lbf
20m 200m
2 3
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
12
300m
Amplitude g/lbf
Amplitude g/lbf
3
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
Amplitude g/lbf
Amplitude g/lbf
50m
200m
23
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
Amplitude g/lbf
Amplitude g/lbf
100m
200m
100m
3 2
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
Amplitude g/lbf
Amplitude g/lbf
50m
200m
1
32 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
Amplitude g/lbf
Amplitude g/lbf
100m
200m
1
3 2 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
2
3 300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
2 300m
Amplitude g/lbf
Amplitude g/lbf
10m 3
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
Amplitude g/lbf
Amplitude g/lbf
50m
200m
1
32
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1 300m
Amplitude g/lbf
Amplitude g/lbf
20m 2
3 200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
300m
Amplitude g/lbf
Amplitude g/lbf
10m 32
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
40m 400m
30m 300m
Amplitude g/lbf
Amplitude g/lbf
1
20m 200m
2
3
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
1
300m
Amplitude g/lbf
Amplitude g/lbf
10m 2
3
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
300m
Amplitude g/lbf
Amplitude g/lbf
10m 23
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
300m
Amplitude g/lbf
Amplitude g/lbf
1
20m
2 200m
3
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
15m
300m
Amplitude g/lbf
Amplitude g/lbf
10m 32
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
300m
Amplitude g/lbf
Amplitude g/lbf
10m
23
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1 300m
Amplitude g/lbf
Amplitude g/lbf
20m
32 200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
300m
Amplitude g/lbf
2
Amplitude g/lbf
10m 3
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
300m
Amplitude g/lbf
Amplitude g/lbf
10m 1
3 200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
300m
Amplitude g/lbf
Amplitude g/lbf
1
20m 32
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
300m
Amplitude g/lbf
Amplitude g/lbf
10m 2
3
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
1
300m
Amplitude g/lbf
Amplitude g/lbf
10m 2
3
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
300m
Amplitude g/lbf
Amplitude g/lbf
123
20m
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
6m
300m
Amplitude g/lbf
Amplitude g/lbf
4m
200m
2m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
40m 400m
30m 300m
Amplitude g/lbf
Amplitude g/lbf
20m 200m
1
2
10m 3 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
12
3
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1
300m
Amplitude g/lbf
Amplitude g/lbf
20m 2
3 200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1
300m
Amplitude g/lbf
Amplitude g/lbf
20m
2 200m
3
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
Amplitude g/lbf
Amplitude g/lbf
100m
200m
1 100m
32
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
40m 400m
30m 300m
Amplitude g/lbf
Amplitude g/lbf
20m 21 200m
3
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
300m
Amplitude g/lbf
Amplitude g/lbf
20m
200m
231
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
Amplitude g/lbf
Amplitude g/lbf
1
100m
2 200m
3
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
Amplitude g/lbf
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
300m
Amplitude g/lbf
Amplitude g/lbf
20m
200m
10m
2 3 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m 2
3
300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m 1
2
3
300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
300m
Amplitude g/lbf
Amplitude g/lbf
10m
2 200m
5m 3
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
Amplitude g/lbf
20m 200m
10m 100m
1 2
3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m
Amplitude g/lbf
Amplitude g/lbf
20m
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
300m
Amplitude g/lbf
Amplitude g/lbf
20m
200m
10m 32
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
300m
Amplitude g/lbf
Amplitude g/lbf
2 3
20m
200m
10m
100m
1 2
3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
300m
Amplitude g/lbf
Amplitude g/lbf
12
20m
3
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
300m
Amplitude g/lbf
Amplitude g/lbf
10m
2
3 200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
300m
Amplitude g/lbf
Amplitude g/lbf
2
20m
3 200m
10m
100m
1 2
3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
13 2 300m
Amplitude g/lbf
Amplitude g/lbf
20m
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
300m
Amplitude g/lbf
Amplitude g/lbf
2 1
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
2 300m
Amplitude g/lbf
Amplitude g/lbf
20m
3 200m
10m
100m
1 2
3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
300m
Amplitude g/lbf
Amplitude g/lbf
1
20m
200m
3
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
1 300m
Amplitude g/lbf
Amplitude g/lbf
10m 3
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
2 300m
Amplitude g/lbf
Amplitude g/lbf
20m 3
200m
10m
100m
1 2
3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m 1
300m
Amplitude g/lbf
Amplitude g/lbf
3
20m
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1
400m
15m 2
3
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m 2 3
300m
Amplitude g/lbf
Amplitude g/lbf
20m
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m
Amplitude g/lbf
Amplitude g/lbf
2
40m 3
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1 300m
Amplitude g/lbf
Amplitude g/lbf
20m 2
3
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
60m
2
300m
Amplitude g/lbf
Amplitude g/lbf
3
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
3
300m
Amplitude g/lbf
Amplitude g/lbf
20m
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
300m
Amplitude g/lbf
Amplitude g/lbf
1
20m
2
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
1
300m
Amplitude g/lbf
Amplitude g/lbf
100m 2
200m
3
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
2 400m
30m
300m
Amplitude g/lbf
Amplitude g/lbf
3
20m
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
15m
300m
Amplitude g/lbf
Amplitude g/lbf
2
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
2
300m
Amplitude g/lbf
Amplitude g/lbf
50m
3
200m
100m
1 2
3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
1
300m
Amplitude g/lbf
Amplitude g/lbf
10m 2
3
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
40m 400m
2
30m 300m
Amplitude g/lbf
Amplitude g/lbf
20m 200m
10m 100m
1 2
3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
3 1 2 300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
1 300m
Amplitude g/lbf
Amplitude g/lbf
2
10m 3
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1
300m
Amplitude g/lbf
2
Amplitude g/lbf
20m 3
200m
10m
100m
1 2
3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
2
400m
15m
3 300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
300m
Amplitude g/lbf
Amplitude g/lbf
10m 1
2 3
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1
300m
Amplitude g/lbf
Amplitude g/lbf
20m 2
3 200m
10m
100m
1 2
3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1 300m
Amplitude g/lbf
Amplitude g/lbf
20m 2
200m
3
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
123 300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1
300m
Amplitude g/lbf
Amplitude g/lbf
20m
2
3
200m
10m
100m
1 2
3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1 300m
Amplitude g/lbf
Amplitude g/lbf
2
20m 3
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
15m
1
32
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
300m
Amplitude g/lbf
Amplitude g/lbf
1
20m 3 2
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1 300m
Amplitude g/lbf
Amplitude g/lbf
20m 3 2
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1
32 400m
15m
300m
Amplitude g/lbf
Amplitude g/lbf
10m
200m
5m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
30m 300m
Amplitude g/lbf
Amplitude g/lbf
3
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m 1
2
3 300m
Amplitude g/lbf
Amplitude g/lbf
20m
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
30m
1
2
300m
Amplitude g/lbf
Amplitude g/lbf
3
20m
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
30m 300m
Amplitude g/lbf
Amplitude g/lbf
3
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
3
Amplitude g/lbf
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
Enclosure 3
Collector End Phase Connection Frequency Response
(Amplitude versus Frequency)
GE Proprietary Information. This document contains proprietary information of the General Electric Company and
may not be used or disclosed to others, except with the written permission of General Electric Company. 9
400m
1
300m
Amplitude g/lbf
Amplitude g/lbf
100m
3
200m
100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
Amplitude g/lbf
Amplitude g/lbf
1
100m
2
200m
3
100m
1
2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
300m
Amplitude g/lbf
1
Amplitude g/lbf
200m
200m
2
100m 3
100m
1 2
3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
2 300m
Amplitude g/lbf
Amplitude g/lbf
50m 3
200m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
1 300m
Amplitude g/lbf
Amplitude g/lbf
100m
2 200m
3
100m
1
2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
1
300m
Amplitude g/lbf
Amplitude g/lbf
100m 2
3
200m
100m
1
2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
1
2 300m
Amplitude g/lbf
Amplitude g/lbf
3
100m
200m
100m
2 3
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m
Amplitude g/lbf
Amplitude g/lbf
200m
200m
1 2
100m
100m
3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
Amplitude g/lbf
Amplitude g/lbf
1
100m
2 200m
3
100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
Amplitude g/lbf
Amplitude g/lbf
3 2
100m
200m
100m
1 3
2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
3
300m
Amplitude g/lbf
Amplitude g/lbf
200m
200m
100m 1 3
100m
2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1
400m
300m
Amplitude g/lbf
Amplitude g/lbf
100m 2
3
200m
100m
2 3
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
300m
Amplitude g/lbf
Amplitude g/lbf
200m 3 2
200m
100m
100m
2 3
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
300m
Amplitude g/lbf
Amplitude g/lbf
200m 2
3
200m
100m 2
100m
3
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
600m
300m
Amplitude g/lbf
Amplitude g/lbf
400m
200m
2
3
200m
100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m 400m
300m 3 2 300m
Amplitude g/lbf
Amplitude g/lbf
200m 200m
2 3
100m 100m
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
Amplitude g/lbf
200m
200m
100m
100m 2
1 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
Amplitude g/lbf
100m
200m
3
100m
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m 400m 3
300m 300m
Amplitude g/lbf
Amplitude g/lbf
200m 200m
3
100m 100m
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
1
300m
Amplitude g/lbf
Amplitude g/lbf
200m 2
3
200m
100m 3
100m
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
1
300m
Amplitude g/lbf
Amplitude g/lbf
200m
2
3 200m
100m
100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
300m
Amplitude g/lbf
Amplitude g/lbf
1 2
200m
3 200m
100m 3
100m 2
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
2
300m
Amplitude g/lbf
Amplitude g/lbf
100m 3
200m
100m 3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
2
400m
300m
Amplitude g/lbf
Amplitude g/lbf
3
50m
200m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
Amplitude g/lbf
1
Amplitude g/lbf
3 2
100m
200m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
2 3
300m
Amplitude g/lbf
Amplitude g/lbf
100m
200m
100m 1
2
3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
Amplitude g/lbf
40m
200m
20m
100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
1
300m
Amplitude g/lbf
Amplitude g/lbf
2
100m 3
200m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m
Amplitude g/lbf
Amplitude g/lbf
3
100m
200m
100m 1
2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
2
300m
Amplitude g/lbf
Amplitude g/lbf
3
100m
200m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m 400m
300m 300m
Amplitude g/lbf
Amplitude g/lbf
2
200m 200m
3
3
100m 100m
1
2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
300m
Amplitude g/lbf
Amplitude g/lbf
1
200m
2
200m
100m 3 100m 1
3
2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m 400m
2
300m 300m
Amplitude g/lbf
Amplitude g/lbf
3
200m 200m
100m 100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
1 300m
Amplitude g/lbf
Amplitude g/lbf
2
200m
200m
3
100m
100m 1
3
2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
2 1
300m
Amplitude g/lbf
Amplitude g/lbf
200m 3
200m
100m 3
100m 1
2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
3 300m
Amplitude g/lbf
Amplitude g/lbf
50m
200m
100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1
400m
60m
300m
Amplitude g/lbf
Amplitude g/lbf
40m 2
3
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
300m
Amplitude g/lbf
Amplitude g/lbf
1
200m
200m
3 2
100m
100m
1 3
2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
32
300m
Amplitude g/lbf
Amplitude g/lbf
50m
200m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
1
300m
Amplitude g/lbf
Amplitude g/lbf
100m
2 200m
3
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
2
400m
3
300m
Amplitude g/lbf
Amplitude g/lbf
100m
200m
100m
3
1
2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
Amplitude g/lbf
Amplitude g/lbf
50m
200m
100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
20m
100m
2 3
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m 400m
300m 300m
Amplitude g/lbf
Amplitude g/lbf
3 2
2
200m 200m
100m 100m 3
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
60m
300m
Amplitude g/lbf
Amplitude g/lbf
2 3
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
1
300m
Amplitude g/lbf
Amplitude g/lbf
2
100m 3
200m
100m
1 3
2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m 1 2 3
300m
Amplitude g/lbf
Amplitude g/lbf
200m
200m
100m 2
100m 3
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
1
3 2
300m
Amplitude g/lbf
Amplitude g/lbf
100m
200m
100m
2 3
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
3
300m
Amplitude g/lbf
Amplitude g/lbf
100m
200m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
21 400m
3
300m
Amplitude g/lbf
Amplitude g/lbf
100m
200m
100m 3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m 400m
300m 300m
Amplitude g/lbf
Amplitude g/lbf
3 2
200m 200m
100m 100m 2
1 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
300m
Amplitude g/lbf
Amplitude g/lbf
2
200m
200m
2
3
100m
100m
1 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
300m
Amplitude g/lbf
Amplitude g/lbf
1
200m
200m
3 2
100m
100m 2
3
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
1 300m
Amplitude g/lbf
Amplitude g/lbf
200m
2 200m
100m 3
100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m
Amplitude g/lbf
Amplitude g/lbf
100m
200m
100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
1
300m
Amplitude g/lbf
Amplitude g/lbf
200m
2 200m
3
100m
100m
3
2
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m
Amplitude g/lbf
Amplitude g/lbf
100m
200m
1
100m
3
2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m 1
300m
Amplitude g/lbf
Amplitude g/lbf
2
200m
3 200m
100m
100m 2 3
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
300m
Amplitude g/lbf
Amplitude g/lbf
3 21
200m
200m
100m 1
100m
2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
Amplitude g/lbf
Amplitude g/lbf
1
2
100m
3
200m
100m 3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
1 300m
Amplitude g/lbf
Amplitude g/lbf
100m
2 200m
3
100m
1 3
2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
1
300m
Amplitude g/lbf
Amplitude g/lbf
2
3
200m
1
200m
3
100m
100m
2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m
Amplitude g/lbf
Amplitude g/lbf
20m
200m
10m
100m
2 3
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
2 3 1
300m
Amplitude g/lbf
Amplitude g/lbf
100m
200m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
1 300m
Amplitude g/lbf
Amplitude g/lbf
3 2
200m
200m 1
100m
100m 3
2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m
21
3 300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
20m
100m
2 3
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
1
300m
Amplitude g/lbf
Amplitude g/lbf
100m
200m
3 2
100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m 1
300m
Amplitude g/lbf
Amplitude g/lbf
200m
200m
2
100m 3
100m 3
2
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m
Amplitude g/lbf
Amplitude g/lbf
100m
2 3
200m
100m
2 3
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m
Amplitude g/lbf
Amplitude g/lbf
2
100m
3 200m
100m
2 3
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m 1
300m
Amplitude g/lbf
Amplitude g/lbf
200m
200m
2
100m 3
100m 3
2
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
32 400m
300m
Amplitude g/lbf
Amplitude g/lbf
100m
200m
100m
2 3
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
Amplitude g/lbf
Amplitude g/lbf
1
100m 2
200m
3
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1 400m
300m 2
300m
Amplitude g/lbf
Amplitude g/lbf
200m 3
200m
100m
100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
Amplitude g/lbf
Amplitude g/lbf
100m
200m 3
1
100m 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
32
300m
Amplitude g/lbf
Amplitude g/lbf
100m
200m
3
100m
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
3 400m
300m
Amplitude g/lbf
Amplitude g/lbf
50m
200m
100m 3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
Amplitude g/lbf
100m
200m
100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
20m
100m
2
1 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
2 300m
Amplitude g/lbf
Amplitude g/lbf
400m 3
200m
200m
100m
2 3
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
40m 400m
3
30m 300m
Amplitude g/lbf
Amplitude g/lbf
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m 1
2
3
300m
Amplitude g/lbf
Amplitude g/lbf
40m
200m
20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m
Amplitude g/lbf
Amplitude g/lbf
200m
200m
100m
100m 3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
30m 300m
Amplitude g/lbf
Amplitude g/lbf
20m 200m
10m 100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m
Amplitude g/lbf
Amplitude g/lbf
20m
200m
10m
100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
12 300m
Amplitude g/lbf
Amplitude g/lbf
100m 3
200m
100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
21 300m
Amplitude g/lbf
Amplitude g/lbf
3
100m
200m
100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
60m 1
300m
Amplitude g/lbf
Amplitude g/lbf
40m 23
200m
20m
100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
2 3 400m
300m
Amplitude g/lbf
Amplitude g/lbf
50m
200m
100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
1
300m
Amplitude g/lbf
Amplitude g/lbf
2
100m 3
200m
100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
1
300m
Amplitude g/lbf
Amplitude g/lbf
100m
2 200m
3 100m
2 3
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
12 300m
Amplitude g/lbf
Amplitude g/lbf
100m
3 200m
100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
Amplitude g/lbf
200m
200m
100m 3
100m
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
1
400m
300m
300m
Amplitude g/lbf
Amplitude g/lbf
200m
200m
2
100m 3
100m 1
2
3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
1
300m
Amplitude g/lbf
Amplitude g/lbf
200m 2
3
200m
100m 3
100m 1
2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m
Amplitude g/lbf
Amplitude g/lbf
3
50m
200m
100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
1 32
300m
Amplitude g/lbf
Amplitude g/lbf
100m
200m
100m
2 3
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m 400m
300m 300m
Amplitude g/lbf
Amplitude g/lbf
200m 2 200m
3
100m 100m 1
2
3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
Amplitude g/lbf
20m
200m
10m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
2
300m
Amplitude g/lbf
Amplitude g/lbf
50m
3
200m
100m
2 3
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
1
2
300m
Amplitude g/lbf
Amplitude g/lbf
200m
3
200m
100m
100m
1 3
2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
12
300m
Amplitude g/lbf
Amplitude g/lbf
100m
3
200m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m
Amplitude g/lbf
Amplitude g/lbf
100m 3
200m
100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m
1 2
3 300m
Amplitude g/lbf
Amplitude g/lbf
200m
200m
100m 3
100m 1
2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
300m 300m
Amplitude g/lbf
Amplitude g/lbf
200m 200m
100m 100m 3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
Amplitude g/lbf
200m
200m
3
100m 1
100m
2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
400m
300m 1 2
3 300m
Amplitude g/lbf
Amplitude g/lbf
200m
200m
100m 1
100m 3
2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz
- TIGHT = GREEN
- HOLLOW = YELLOW
- LOOSE = RED
A single wedge was found to be loose. No wedge was found to be hollow, and all other are
green. The results of this test were within the GE recommended acceptable standards for
wedge tightness.
270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 1345 of 1653
Wedge Map - 290T818
58 672 784 747 716 688 689 731 789 736 754 757 733 775 779 709 681 732 773 775 782
59 663 726 760 765 695 719 779 767 719 761 786 787 765 758 746 783 675 744 762 691
60 657 773 792 727 722 766 765 713 742 778 714 776 722 781 753 757 747 745 733 766
61 653 723 729 692 702 717 753 736 709 757 756 804 758 742 764 753 768 742 792 757
62 665 792 743 774 774 703 780 800 739 745 690 753 797 744 784 748 707 722 777 733
63 699 758 759 791 755 753 768 771 755 766 781 746 801 724 714 771 786 688 736 714
64 764 757 756 770 774 728 765 787 765 763 788 709 698 751 739 758 782 751 717 776
65 739 773 753 713 758 787 781 776 758 781 762 776 782 771 794 757 776 777 752 713
66 703 680 808 726 729 788 754 788 772 769 774 775 774 736 735 793 801 709 703 726
67 756 761 774 695 761 789 757 791 733 795 764 761 737 791 753 798 776 792 706 722
68 756 709 748 732 675 735 780 766 813 814 792 762 736 719 759 787 755 769 768 741
69 721 770 742 746 757 769 762 789 715 734 762 761 764 705 759 787 785 733 712 706
70 743 771 755 746 782 769 743 741 797 797 734 736 742 750 747 771 753 744 720 763
71 708 764 776 776 758 804 717 767 744 739 760 780 727 728 790 725 756 751 711 740
72 733 747 761 790 764 772 750 768 736 720 772 774 809 721 689 796 733 682 680 783
21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36
757 756 726 794 756 766 767 795 726 770 778 767 745 801 778 675
775 753 750 775 710 773 804 726 766 762 799 766 732 726 793 665
767 798 776 779 788 759 794 742 812 808 771 755 782 763 788 667
778 780 764 774 767 761 743 765 779 742 770 771 728 738 757 695
719 747 757 765 775 708 740 773 794 740 695 733 741 742 791 665
783 791 694 768 763 711 781 737 731 778 774 792 739 783 747 658
766 725 727 755 804 686 806 712 787 747 761 740 728 778 742 677
807 755 720 733 758 779 733 739 746 757 686 749 750 761 753 708
766 743 522 780 763 741 706 749 763 767 748 758 768 741 769 748
792 689 782 721 691 717 742 744 775 760 708 720 776 773 765 724
777 766 734 720 709 719 763 785 710 772 695 761 767 723 754 740
766 737 776 753 702 768 755 757 788 770 713 757 759 714 739 752
753 780 800 706 727 757 787 803 707 770 737 774 753 708 729 707
755 750 753 764 760 776 720 798 798 712 714 765 775 759 729 722
754 737 758 750 769 756 776 776 678 774 780 790 745 714 719 731
757 739 773 780 716 750 769 751 758 766 720 755 768 770 719 754
761 725 733 724 777 770 752 743 796 744 769 764 731 771 754 684
753 734 777 774 759 773 774 720 779 801 775 745 722 745 722 752
778 729 757 770 755 746 724 767 801 730 775 720 741 749 796 703
767 763 751 778 717 672 742 765 808 803 767 776 764 764 774 731
768 716 663 773 756 761 730 720 697 710 786 721 773 710 807 706
732 724 754 772 745 729 761 682 698 704 727 743 719 738 721 785
756 730 672 726 695 676 724 714 761 690 685 710 719 689 742 803
728 753 700 712 735 757 704 761 750 777 691 732 687 727 697 785
743 747 752 771 772 743 733 705 692 737 776 683 718 732 699 730
664 763 704 701 777 769 729 676 732 719 731 716 686 712 700 753
743 727 715 766 699 707 722 715 759 671 734 796 678 784 746 663
736 708 709 735 692 738 778 747 691 728 731 722 734 726 720 719
669 664 663 719 739 765 746 793 712 678 731 729 744 719 747 725
724 726 749 701 765 744 720 695 743 760 707 756 720 713 732 705
779 758 753 766 721 736 715 694 730 692 711 680 703 673 768 652
757 696 728 716 713 726 697 713 731 734 686 764 675 767 763 684
700 692 736 775 719 744 735 717 707 769 711 674 763 779 796 729
700 682 765 714 739 710 693 763 700 687 704 707 736 789 704 770
700 764 768 763 693 734 751 690 701 707 699 730 758 744 780 754
723 705 742 767 729 754 751 753 735 688 731 697 719 686 716 710
740 704 722 727 712 747 715 720 769 719 766 695 711 709 742 659
743 699 666 747 725 735 775 730 802 678 706 702 771 714 728 725
738 711 681 673 758 697 695 740 738 691 707 724 708 772 777 707
726 687 745 767 731 798 731 784 757 770 730 668 714 688 795 750
697 751 729 698 741 717 739 754 701 739 731 712 691 701 718 776
784 768 725 769 751 794 751 769 758 759 732 727 704 756 747 693
684 720 788 756 753 761 741 747 717 733 732 718 735 734 763 691
680 729 768 784 693 746 754 702 708 734 702 795 738 706 775 721
716 757 773 801 767 765 749 772 737 824 701 735 698 743 774 721
695 724 726 772 726 792 773 791 756 764 712 791 740 705 764 655
711 756 805 766 787 770 761 719 807 752 741 740 680 717 797 661
762 773 749 736 744 774 688 786 770 692 718 730 727 721 779 686
699 759 742 726 695 721 750 801 753 762 729 710 755 723 711 689
739 763 779 781 754 731 756 774 730 739 712 734 711 673 735 690
738 718 796 770 724 746 784 765 749 729 734 782 749 780 769 677
709 788 793 774 705 787 795 785 757 795 756 758 751 766 766 722
792 743 760 715 788 772 769 746 757 750 774 730 744 794 771 736
753 777 711 759 765 717 711 701 753 796 786 729 780 681 765 734
774 776 773 730 715 722 775 753 763 776 749 749 742 707 717 756
785 784 751 715 718 716 740 757 727 724 776 731 736 756 786 730
766 776 735 751 768 763 733 744 752 781 758 707 787 772 702 811
749 734 713 788 732 768 741 728 718 743 746 720 763 733 743 762
773 734 727 700 752 747 753 780 770 797 784 796 740 745 779 698
712 758 778 779 798 769 755 768 701 746 747 741 764 752 770 746
739 788 769 806 777 748 786 753 754 752 729 764 749 805 782 792
760 765 794 739 750 743 741 737 760 753 746 724 762 780 760 711
745 705 751 677 697 739 782 755 761 758 791 680 798 754 760 750
735 707 782 658 757 752 809 795 747 763 677 796 715 750 778 764
755 705 713 725 784 670 790 768 724 747 701 752 722 793 790 766
792 783 741 733 753 742 778 794 752 714 778 738 734 719 776 737
724 759 691 770 732 706 738 732 765 779 739 773 805 758 760 742
773 732 743 784 738 725 765 739 769 727 754 721 716 795 767 785
736 673 767 749 757 720 769 723 754 736 763 743 774 792 781 696
753 767 735 757 768 762 806 784 773 790 744 775 770 737 748 763
759 721 775 757 712 777 781 781 734 778 726 790 776 800 770 761
769 763 785 800 752 749 789 778 762 720 753 792 759 731 784 762
The ELCID compared the flux density at all locations to a reference signal. Flux density
throughout the core was consistent and it showed that there were no problems and no
deviation between the reference and the local sign was picked up by the test set. All readings
were below 100mA and the stator core was considered approved as satisfactory.
ELCID Picture
270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 1350 of 1653
CHILCA UNO - ENGIE - ELCID_results
Heading
Comments:
Final EL-CID testing.
Description of test
The Black trace indicates the trolley movement was from the CE (Collector
End) to TE (Turbine End).
The Blue trace indicates the trolley movement was from the TE (Turbine
End) to CE (Collector End).
No slot had any indications equal to or greater than 100 mA during this test.
The following page (peaks) indicates the highest readings during the
performance of the test.
Comments:
Comments:
Slots 1-6
Slots 7-12
Slots 13-18
Slots 19-24
Slots 25-30
Slots 31-36
Slots 37-42
Slots 43-48
Slots 49-54
Slots 55-60
Slots 61-66
Slots 67-72
270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 1366 of 1653
d316218 - Hipotential Testing Agreem…
Customer: ENGIE -Chilca 1 Turbine Serial No. 270T818 Project ID: ERP-10339092
X I agree with the use of the above GE Recommended Test Voltages for this unit. LZA (Initials)
I disagree with the use of the above GE Recommended Test Voltages. I understand that IEEE (Initials)
95-2002 recommends 1.25E to 1.5E AC RMS for a hipot test value. I request the following:
GE Proprietary and Confidential Information. Not to be distributed or reproduced to third parties without prior GE approval
D316218 Sheet: Test & Inspect Rev 2.2 - 02/12/2020
270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 1368 of 1653
D3162041 - Armature Winding Resist…
Comments
GE Proprietary and Confidential Information. Not to be distributed or reproduced to third parties without prior GE approval
D3162041 Sheet: (a) Rev 2.2 - 03/11/2020
Visual inspection and troubleshooting tests were made in order to find the possible reason
for the low values on center phase. Although, we couldn't get the center phase to have
acceptable values according to GE standards
"Luego de varios días de tratamiento térmico en los cuales se incrementó la temperatura del
estator hasta los 60C, hemos evidenciado una mejora en la resistencia de aislamiento (IR),
sin embargo el índice de polarización (PI) no aumenta y la tendencia se ha mantenido
estática en las últimas 48 horas.
En esta condición, ENGIE, bajo su cuenta y riesgo, podría considerar las siguientes
acciones para intentar mejorar los parámetros eléctricos actuales en la fase S del estator del
generador:
270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 1370 of 1653
GE Power Power Services
270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 1371 of 1653
d3162043 - Stator Winding Insulation …
Stator Winding Insulation Resistance / HV Proof Tests
Generator Test & Inspection
Date 02/24/2021 Generator No.: 290T818 Prepared by: Renan Lopes / Erica Koono
Equipment 324 Marina Anders / Marília Oliveira
OEM GE Stator Voltage (kV): 18.0 Project ID: 10339092
DC INSULATION RESISTANCE (Megohms) per TM2030
Voltage: 5000 Volts
Time(Min) Left (CE) Center (CE) Right (CE) 10 Minute Insulation Resistance
0.5 1083 397 1172
1.0 2050 470 2210 14000
2.0 3560 516 3690
3.0 4940 536 4950 12000
4.0 6150 544 5940
5.0 7490 550 6990 M 10000
E
6.0 8720 552 7850
G
7.0 10110 557 8860 8000
O
8.0 10810 556 9800 H
9.0 12160 557 10370 M 6000
10.0 13190 558 11080 S
GE Proprietary and Confidential Information. Not to be distributed or reproduced to third parties without prior GE approval
D3162043 Sheet: (a) Rev 2.1 - 08/05/2020
Below you can find the settings used for the test performed.
270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 1373 of 1653
d316205 - SPHERE GAP SETTINGS
Notes:
The DC or 0.1 Hz 6.25 cm settings are good for 10 KV to 88 KV.
The AC (RMS) 12.5 cm settings are good for 10 KV to 65 KV.
The AC (RMS) 6.25 cm settings are good for 10 KV to 62 KV.
Comments:
The leakage current measurement is done in principle phase wise. The leakage current
measurement is carried out directly after the charging current measurement up to a voltage
of 2*UN. The leakage current measurement is done between the winding and the earthed
stator iron core.
With applied DC-voltage to the winding, the currents flowing to earth and through the phases
not staying under voltage are measured. The applied DC- voltage must be gradually
increased according to a precisely defined time program. At every voltage step, after
prescribed times, the corresponding currents are to be measured.
This test was only made on right and left phases, because center phase doesn't present
permissive values for High Voltages Tests. Below you can find the test results.
270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 1375 of 1653
d3162044 - Armature Insulation DC L…
A 15 KV DC voltage was applied to each phase with the other two phases grounded for
a period of 10 minutes. Readings were recorded at specific time intervals. On the basis of these readings a
time schedule is established for reading stabilized leakage currents at successively higher voltage values up to
a maximum value, approximately twice line-to-line voltage. The current readings are plotted as a function of
voltage to determine if a nearly linear relationship exists, indicating a constant insulation resistance as a
function of voltage.
270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 1377 of 1653
d316403 - RTD Test - Dual Element
RTD Test
Dual Element - Copper, Nickel, Platinum or Special
Date 2/25/21 Generator Serial No. 290T818 Prepared By Marília Oliveira
Erica Koono
Turbine Serial No. 270T818 Project ID C-10339092
Test Article Reference: TM2010
Winding Temperature: 34 ºC
Device: Fluke 87 V
Type must be entered as follows: C, N, P or O. *See Note below.
RTD RTD RESISTANCE Indicated Customer
Remarks
No. Type* AB AC BC (AB+AC)/2 - BC Temp. ºC Temp ºC
1 P 114.30 114.30 1.60 112.70 32.99 SLOT 1 - TE
1' P 114.30 114.20 1.60 112.65 32.86 SLOT 1 - TE
2 P 114.80 114.80 1.60 113.20 34.29 SLOT 25 - TE
2' P 114.80 114.80 1.60 113.20 34.29 SLOT 25 - TE
3 P 113.80 113.80 1.40 112.40 32.21 SLOT 49 - TE
3' P 113.80 113.80 1.40 112.40 32.21 SLOT 49 - TE
4 P 113.70 113.70 1.10 112.60 32.73 SLOT 13 - CE
4' P 113.80 113.80 1.10 112.70 32.99 SLOT 13 - CE
5 P 113.60 113.60 0.90 112.70 32.99 SLOT 37 - CE
5' P 113.60 113.60 0.90 112.70 32.99 SLOT 37 - CE
6 P 112.90 112.90 0.80 112.10 31.43 SLOT 61 - CE
6' P 113.00 112.90 0.80 112.15 31.56 SLOT 61 - CE
7
7'
8
8'
9
9'
10
10'
11
11'
12
12'
*RTD Type must be entered as: C, N, P or O O = User Defined RTD Characteristics
Standard RTDs Material Name =
C = Copper 10 Ω @ 25 ºC Reference Resistance RREF = ohms
N = Nickel 120 Ω @ 0 ºC Reference Temperature TREF = ºC
P = Platinum 100 Ω @ 0 ºC (DIN Standard) Coefficient of resistance (α) =
Non-Standard RTDs ohms per ohm /per ºC
O = User defined as described at right RTD Information Source
Megger SN: 101343997 Calibration Date: 6/8/20 Due Date: 7/8/21
Fluke SN: 44840054 Calibration Date: 9/21/20 Due Date: 9/21/21
GE Proprietary and Confidential Information. Not to be distributed or reproduced to third parties without prior GE approval
D316403 Sheet: 1 thru 12 Rev 3.1 - 05/15/2020
RTD Test
Dual Element - Copper, Nickel, Platinum or Special
Date 2/25/21 Generator Serial No. 290T818 Prepared By Marília Oliveira
Erica Koono
Turbine Serial No. 270T818 Project ID C-10339092
Winding Temperature: 34 ºC
Device: Fluke 87 V
Type must be entered as follows: C, N, P or O. *See Note below.
RTD RTD RESISTANCE Indicated Customer
Remarks
No. Type* AB AC BC (AB+AC)/2 - BC Temp. ºC Temp ºC
13
13'
14
14'
15
15'
16
16'
17
17'
18
18'
19
19'
20 P 115.80 115.80 2.00 113.80 35.84 SLOT 14 - CENTER/TE
20' P 115.80 115.80 2.00 113.80 35.84 SLOT 14 - CENTER/TE
21 P 115.50 115.50 1.90 113.60 35.32 SLOT 38 - CENTER/TE
21' P 115.50 115.50 1.80 113.70 35.58 SLOT 38 - CENTER/TE
22 P 114.90 114.90 1.80 113.10 34.03 SLOT 62 - CENTER/TE
22' P 114.80 114.90 1.90 112.95 33.64 SLOT 62 - CENTER/TE
23
23'
24
24'
*RTD Type must be entered as: C, N, P or O O = User Defined RTD Characteristics
Standard RTDs Material Name =
C = Copper 10 Ω @ 25 ºC Reference Resistance RREF = ohms
N = Nickel 120 Ω @ 0 ºC Reference Temperature TREF = ºC
P = Platinum 100 Ω @ 0 ºC (DIN Standard) Coefficient of resistance (α) =
Non-Standard RTDs ohms per ohm /per ºC
O = User defined as described at right RTD Information Source
Megger SN: 101343997 Calibration Date: 6/8/20 Due Date: 7/8/21
Fluke SN: 44840054.0000 Calibration Date: 9/21/20 Due Date: 9/21/21
GE Proprietary and Confidential Information. Not to be distributed or reproduced to third parties without prior GE approval
D316403 Sheet: 13 thru 24 Rev 3.1 - 05/15/2020
RTD Test
Dual Element - Copper, Nickel, Platinum or Special
Date 2/25/21 Generator Serial No. 290T818 Prepared By Marília Oliveira
Erica Koono
Turbine Serial No. 270T818 Project ID C-10339092
Winding Temperature: 34 ºC
Device: Fluke 87 V
Type must be entered as follows: C, N, P or O. *See Note below.
RTD RTD RESISTANCE Indicated Customer
Remarks
No. Type* AB AC BC (AB+AC)/2 - BC Temp. ºC Temp ºC
25
25'
26
26'
27
27'
28
28'
29
29'
30
30'
31 P 115.20 115.40 2.10 113.20 34.29 SLOT 2 - CENTER/TE
31' P 115.20 115.20 2.00 113.20 34.29 SLOT 2 - CENTER/TE
32 P 115.90 115.90 2.00 113.90 36.10 SLOT 26 - CENTER/TE
32' P 115.90 115.90 1.90 114.00 36.36 SLOT 26 - CENTER/TE
33 P 115.00 114.90 1.70 113.25 34.42 SLOT 50 - CENTER/TE
33' P 114.80 114.90 1.70 113.15 34.16 SLOT 50 - CENTER/TE
34 P 114.30 114.40 1.30 113.05 33.90 SLOT 3 - CENTER/CE
34' P 114.30 114.30 1.40 112.90 33.51 SLOT 3 - CENTER/CE
35 P 114.10 114.10 1.00 113.10 34.03 SLOT 27 - CENTER/CE
35' P 115.00 115.00 1.30 113.70 35.58 SLOT 27 - CENTER/CE
36 P 115.00 115.00 1.30 113.70 35.58 SLOT 51 - CENTER/CE
36' P 114.10 114.00 1.10 112.95 33.64 SLOT 51 - CENTER/CE
*RTD Type must be entered as: C, N, P or O O = User Defined RTD Characteristics
Standard RTDs Material Name =
C = Copper 10 Ω @ 25 ºC Reference Resistance RREF = ohms
N = Nickel 120 Ω @ 0 ºC Reference Temperature TREF = ºC
P = Platinum 100 Ω @ 0 ºC (DIN Standard) Coefficient of resistance (α) =
Non-Standard RTDs ohms per ohm /per ºC
O = User defined as described at right RTD Information Source
Megger SN: 101343997 Calibration Date: 6/8/20 Due Date: 7/8/21
Fluke SN: 44840054.0000 Calibration Date: 9/21/20 Due Date: 9/21/21
GE Proprietary and Confidential Information. Not to be distributed or reproduced to third parties without prior GE approval
D316403 Sheet: 25 thru 36 Rev 3.1 - 05/15/2020
RTD Test
Dual Element - Copper, Nickel, Platinum or Special
Date 2/25/21 Generator Serial No. 290T818 Prepared By Marília Oliveira
Erica Koono
Turbine Serial No. 270T818 Project ID C-10339092
GE Proprietary and Confidential Information. Not to be distributed or reproduced to third parties without prior GE approval
D316403 Sheet: RTD Megger Rev 3.1 - 05/15/2020
4.6 Repairs
Insulation
Damage
Ring
Connection
CATEGORY4.6.1
4.6.1 Connection Ring Damage Insulation
FORM
Part Description:
During the process of selective connection ring block removal, the connection ring (item#81
- T2-LEAD T-1) was damage. A repair using mica tape and Cogebi kit was made.
270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 1382 of 1653
GE Power Power Services
270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 1383 of 1653
GE Power Power Services
270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 1384 of 1653
GE Power Power Services
Inspection
Visual
As-Found
CATEGORY4.7.1
4.7.1 As-Found Visual Inspection
FORM
Part Condition: Good
Part Description:
RETAINING RINGS
Retaining Rings were visually inspected in the accessible areas for discoloration caused by
arching between the inboard side of the ring and the field end wedges. The rings were also
inspected for signs of pitting, cracks, or mechanical damage; The overall condition of these
were in a satisfactory condition, nonrelevant defects were observed.
FIELD BODY
The field body was visually inspected for relevant oil contamination, rust, mechanical
damage or any sign that could led to an electrical issue. There was no indication of any of
these issues already mentioned.
FIELD WEDGES
The field wedges were inspected for signs of discoloration or burning caused by a negative
sequence/ arching from circulating current either between wedges or between the end
wedges and the retaining rings. No defects were found.