You are on page 1of 445

GE Power Power Services

4.2 Stator Visual Inspection


Inspection
As-Found
Stator
CATEGORY4.2.1
4.2.1 Stator As-Found Inspection
FORM
Part Description:
END WINDING

A visual inspection was performed on the CE end winding. Ties, blocks, axial support
system, nuts and bar exits were well examined.

Heavy dusting was found at all connection ring- bar connections and moderate dusting in a
few positions as indicated in pictures below. This is the result of mechanical abrasion of the
insulation system due to movement in the end winding.

All axial support hardware was verified to be tight and all nuts well secured with locking tabs
in place. Minor oil contamination was present on the end winding TE side and frame floor.
Cleaning was performed with alcohol and rags. Corrective actions to dusting such as red eye
and flooding resin were applied on all suitable points after TIL 1965 was performed.

CORE IRON

A visual inspection on the Core Iron revealed that there was not mechanical damage,
shorted turns, or some signs of overheating; There were no signs of critically bent punching
or shorted lamination that could result in circulating current or overheating. No signs of
discoloration, burning or overheating were observed.

It was found light red dusting on belly band positions and axial supports.

It was observed that end of Slot on TE side presented black greasing generated by bar
movement and oil dropping from leakage on seal system of the generator. Below you can
find pictures of this findings and a boroscope inspection in order to find any possible damage
on bars.

WEDGES

The stator wedges were visually inspected for dusting that would indicate movement in the
slot during operation. No sign of looseness or critical damage was observed in this area.

BUSHINGS

All six, neutral and line bushing had the porcelain inspected and no cracks were found.

270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 929 of 1653
GE Power Power Services

4.2.1 Stator As-Found Inspection


FORM
Axial _11 Axial support _11

Axial support _12 Between _11 and _12

Between axial _9 and _10 Center Core Left Halt

270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 930 of 1653
GE Power Power Services

4.2.1 Stator As-Found Inspection


FORM
Core nuts CR 2ock I

CR 2ock II CR 4ock I

CR 4ock II CR 6ock

270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 931 of 1653
GE Power Power Services

4.2.1 Stator As-Found Inspection


FORM
CR 10 ock I CR 10 ock II

CR 12ock I CR 12ock II

CR Block 5 ock CR block 6 ock

270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 932 of 1653
GE Power Power Services

4.2.1 Stator As-Found Inspection


FORM
End Winding CE EW Between Bars

EW ties 8 ock 3rd row EW ties 12 ock 1st row

FME on stator core II FME on stator core

270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 933 of 1653
GE Power Power Services

4.2.1 Stator As-Found Inspection


FORM
Gas Baffle TE II Gas baffle TE

Gas Buffle CE OW Gas Buffle CE

Greasing TE II Greasing TE III

270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 934 of 1653
GE Power Power Services

4.2.1 Stator As-Found Inspection


FORM
Gresing TE I Light dusting between Axial support and
Bind Bands

Signs of light red dust on Axial Supports Light dusting on CR blocks

Light Greasing TE CAP Light greasing TE

270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 935 of 1653
GE Power Power Services

4.2.1 Stator As-Found Inspection


FORM
OVW TE Red dusting on BB position

TE ties greasing TE ties

270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 936 of 1653
Chilca Uno - Greasing on TE side.rev2

1 Summary

This report documents findings during Visual Inpection on Stator Core (As-found and After heating
Stator Core). It was oberseved that end of Slot on TE side presented black greasing generated by bar
movement and oil droping from leakage on lubrificant /seal system of the generator.
Below you can find pictures of this findings. The moviment of the bar in the slot together with oil
contamination can generate bar abrasion on stator bar and electrical failure or insulation weakeness.
The greasing was found visually on slot Ends on TE side, but it is recommended to perform a
borescope inspectionto find any damage on lateral bar.

2 Photos

2.1 Slot End Greasing – TE side

Unit / System 290T818 Unit / System 290T818


Appendix No. 1 Appendix No. 2
Remarks Greasing on End Slot Remarks Greasing on End Slot

Page 937 of 1653


Chilca Uno - Greasing on TE side.rev2

Unit / System 290T818 Unit / System 290T818


Appendix No. 3 Appendix No. 4
Remarks Greasing on End Slot Remarks Greasing on End Slot

Unit / System 290T818 Unit / System 290T818


Appendix No. 5 Appendix No. 6
Remarks Greasing on End Slot Remarks Greasing on End Slot

Page 938 of 1653


Chilca Uno - Greasing on TE side.rev2
3 BOROSCOPE INSPECTION OF STATOR BARS

As an attempt to troubleshoot the low Insulation Resistance (IR) measured on center phase of
generator stator 290T818, a borescope inspection was done on turbine end and collector end of
generator stator on February 14 - 16. The equipment tip passed through the vent slots of iron
packages in the core, reaching top and bottom bars in slot. The area covered in the inspection was
end (step) iron, where bar abrasion occurs mainly. 4th package of iron was also inspected to observe
side ripple spring migration.
The findings include dusting and greasing contamination in slots, but no visual evidence of bar
abrasion was found. The possibility of Bar was not removed as this damage could be occurring
between Bar and Step Iron, that is not possible to visually inspect without remove the wedges.

Unit / System 290T818 Unit / System 290T818


Appendix No. 1 Appendix No. 2
Remarks Greasing on bottom bar from slot #18 Remarks Greasing on bottom bar from slot #18

Unit / System 290T818 Unit / System 290T818


Appendix No. 3 Appendix No. 4
Remarks Greasing on bottom bar from slot #18 Remarks Greasing on bottom bar from slot #18

Page 939 of 1653


Chilca Uno - Greasing on TE side.rev2

Unit / System 290T818 Unit / System 290T818


Appendix No. 5 Appendix No. 6
Remarks Greasing on bottom bar from slot #19 Remarks Greasing on bottom bar from slot #19

Unit / System 290T818 Unit / System 290T818


Appendix No. 7 Appendix No. 8
Remarks Greasing on bottom bar from slot #20 Remarks Greasing on bottom bar from slot #20

Unit / System 290T818 Unit / System 290T818


Appendix No. 9 Appendix No. 10
Remarks Greasing on bottom bar from slot #20 Remarks Greasing on bottom bar from slot #20

Page 940 of 1653


Chilca Uno - Greasing on TE side.rev2

Unit / System 290T818 Unit / System 290T818


Appendix No. 11 Appendix No. 12
Remarks Greasing on bottom bar from slot #21 Remarks Greasing on bottom bar from slot #21

Unit / System 290T818 Unit / System 290T818


Appendix No. 13 Appendix No. 14
Remarks Greasing on bottom bar from slot #21 Remarks Greasing on bottom bar from slot #21

Unit / System 290T818 Unit / System 290T818


Appendix No. 15 Appendix No. 16
Remarks Greasing on bottom bar from slot #21 Remarks Greasing on bottom bar from slot #21

Page 941 of 1653


Chilca Uno - Greasing on TE side.rev2

Unit / System 290T818 Unit / System 290T818


Appendix No. 17 Appendix No. 18
Remarks Greasing on bottom bar from slot #22 Remarks Greasing on bottom bar from slot #22a

Unit / System 290T818 Unit / System 290T818


Appendix No. 19 Appendix No. 20
Remarks Greasing on bottom bar from slot #22 Remarks Greasing on bottom bar from slot #2

Unit / System 290T818 Unit / System 290T818


Appendix No. 21 Appendix No. 22
Remarks Greasing on bottom bar from slot #23 Remarks Greasing on bottom bar from slot #23

Page 942 of 1653


Chilca Uno - Greasing on TE side.rev2

Unit / System 290T818 Unit / System 290T818


Appendix No. 23 Appendix No. 24
Remarks Greasing on bottom bar from slot #24 Remarks Greasing on bottom bar from slot #24

Unit / System 290T818 Unit / System 290T818


Appendix No. 25 Appendix No. 26
Remarks Greasing on bottom bar from slot #24 Remarks Greasing on bottom bar from slot #24

Unit / System 290T818 Unit / System 290T818


Appendix No. 27 Appendix No. 28
Remarks Greasing on bottom and top bar from slot #25 Remarks Greasing on bottom and top bar from slot #25

Page 943 of 1653


Chilca Uno - Greasing on TE side.rev2

Unit / System 290T818 Unit / System 290T818


Appendix No. 29 Appendix No. 30
Remarks Greasing on bottom and top bar from slot #25 Remarks Greasing on bottom and top bar from slot #25

Unit / System 290T818 Unit / System 290T818


Appendix No. 31 Appendix No. 32
Remarks Greasing on bottom and top bar from slot #26 Remarks Greasing on bottom and top bar from slot #26

Unit / System 290T818 Unit / System 290T818


Appendix No. 33 Appendix No. 34
Remarks Greasing on bottom and top bar from slot #26 Remarks Greasing on bottom and top bar from slot #26

Page 944 of 1653


Chilca Uno - Greasing on TE side.rev2

Unit / System 290T818 Unit / System 290T818


Appendix No. 35 Appendix No. 36
Remarks Greasing on bottom and top bar from slot #27 Remarks Greasing on bottom and top bar from slot #27

Unit / System 290T818 Unit / System 290T818


Appendix No. 37 Appendix No. 38
Remarks Greasing on bottom and top bar from slot #27 Remarks Greasing on bottom and top bar from slot #27

Unit / System 290T818 Unit / System 290T818


Appendix No. 39 Appendix No. 40
Remarks Greasing on bottom and top bar from slot #28 Remarks Greasing on bottom and top bar from slot #28

Page 945 of 1653


Chilca Uno - Greasing on TE side.rev2

Unit / System 290T818 Unit / System 290T818


Appendix No. 41 Appendix No. 42
Remarks Greasing on bottom and top bar from slot #28 Remarks Greasing on bottom and top bar from slot #28

Unit / System 290T818 Unit / System 290T818


Appendix No. 43 Appendix No. 44
Remarks Greasing on bottom and top bar from slot #28 Remarks Greasing on bottom and top bar from slot #28

Unit / System 290T818 Unit / System 290T818


Appendix No. 45 Appendix No. 46
Remarks Greasing on bottom and top bar from slot #29 Remarks Greasing on bottom and top bar from slot #29

Page 946 of 1653


Chilca Uno - Greasing on TE side.rev2

Unit / System 290T818 Unit / System 290T818


Appendix No. 47 Appendix No. 48
Remarks Greasing on bottom and top bar from slot #29 Remarks Greasing on bottom and top bar from slot #29

Unit / System 290T818 Unit / System 290T818


Appendix No. 49 Appendix No. 50
Remarks Greasing on bottom and top bar from slot #29 Remarks Greasing on bottom and top bar from slot #29

Unit / System 290T818 Unit / System 290T818


Appendix No. 51 Appendix No. 52
Remarks Greasing on top bar from slot #30 Remarks Greasing on top bar from slot #30

Page 947 of 1653


Chilca Uno - Greasing on TE side.rev2

Unit / System 290T818 Unit / System 290T818


Appendix No. 53 Appendix No. 54
Remarks Greasing on top bar from slot #31 Remarks Greasing on top bar from slot #31

Unit / System 290T818 Unit / System 290T818


Appendix No. 55 Appendix No. 56
Remarks Greasing on top bar from slot #31 Remarks Greasing on top bar from slot #31

Unit / System 290T818 Unit / System 290T818


Appendix No. 57 Appendix No. 58
Remarks Greasing on top bar from slot #31 Remarks Greasing on top bar from slot #32

Page 948 of 1653


Chilca Uno - Greasing on TE side.rev2

Unit / System 290T818 Unit / System 290T818


Appendix No. 59 Appendix No. 60
Remarks Greasing on top bar from slot #32 Remarks Greasing on top bar from slot #32

Unit / System 290T818 Unit / System 290T818


Appendix No. 61 Appendix No. 62
Remarks Greasing on top bar from slot #33 Remarks Greasing on top bar from slot #33

Unit / System 290T818 Unit / System 290T818


Appendix No. 63 Appendix No. 64
Remarks Greasing on top bar from slot #34 Remarks Greasing on top bar from slot #34

Page 949 of 1653


Chilca Uno - Greasing on TE side.rev2

Unit / System 290T818 Unit / System 290T818


Appendix No. 65 Appendix No. 66
Remarks Greasing on top bar from slot #34 Remarks Greasing on top bar from slot #34

Unit / System 290T818 Unit / System 290T818


Appendix No. 67 Appendix No. 68
Remarks Greasing on top bar from slot #35 Remarks Greasing on top bar from slot #36

Unit / System 290T818 Unit / System 290T818


Appendix No. 69 Appendix No. 70
Remarks Greasing on top bar from slot #35 Remarks Greasing on top bar from slot #36

Page 950 of 1653


Chilca Uno - Greasing on TE side.rev2

Unit / System 290T818 Unit / System 290T818


Appendix No. 71 Appendix No. 72
Remarks Greasing on top bar from slot #36 Remarks Greasing on top bar from slot #36

Unit / System 290T818 Unit / System 290T818


Appendix No. 73 Appendix No. 74
Remarks Greasing on top bar from slot #36 Remarks Greasing on top bar from slot #36

Unit / System 290T818 Unit / System 290T818


Appendix No. 75 Appendix No. 76
Remarks Greasing on top bar from slot #36 Remarks Greasing on top bar from slot #36

Page 951 of 1653


Chilca Uno - Greasing on TE side.rev2

Unit / System 290T818 Unit / System 290T818


Appendix No. 77 Appendix No. 78
Remarks Greasing on bottom bar from slot #54 Remarks Greasing on bottom bar from slot #54

Unit / System 290T818 Unit / System 290T818


Appendix No. 79 Appendix No. 80
Remarks Greasing on bottom bar from slot #54 Remarks Greasing on bottom bar from slot #55

Unit / System 290T818 Unit / System 290T818


Appendix No. 81 Appendix No. 82
Remarks Greasing on bottom bar from slot #55 Remarks Greasing on bottom bar from slot #55

Page 952 of 1653


Chilca Uno - Greasing on TE side.rev2

Unit / System 290T818 Unit / System 290T818


Appendix No. 83 Appendix No. 84
Remarks Greasing on bottom bar from slot #55 Remarks Greasing on bottom bar from slot #55

Unit / System 290T818 Unit / System 290T818


Appendix No. 85 Appendix No. 86
Remarks Greasing on bottom bar from slot #56 Remarks Greasing on bottom bar from slot #56

Unit / System 290T818 Unit / System 290T818


Appendix No. 87 Appendix No. 88
Remarks Greasing on bottom bar from slot #57 Remarks Greasing on bottom bar from slot #58

Page 953 of 1653


Chilca Uno - Greasing on TE side.rev2

Unit / System 290T818 Unit / System 290T818


Appendix No. 89 Appendix No. 90
Remarks Greasing on bottom bar from slot #58 Remarks Greasing on bottom bar from slot #58

Unit / System 290T818 Unit / System 290T818


Appendix No. 91 Appendix No. 92
Remarks Greasing on bottom bar from slot #58 Remarks Greasing on bottom bar from slot #59

Unit / System 290T818 Unit / System 290T818


Appendix No. 93 Appendix No. 94
Remarks Greasing on bottom bar from slot #59 Remarks Greasing on bottom bar from slot #59

Page 954 of 1653


Chilca Uno - Greasing on TE side.rev2

Unit / System 290T818 Unit / System 290T818


Appendix No. 95 Appendix No. 96
Remarks Greasing on bottom bar from slot #60 Remarks Greasing on bottom bar from slot #60

Unit / System 290T818 Unit / System 290T818


Appendix No. 97 Appendix No. 98
Remarks Greasing on bottom bar from slot #60 Remarks Greasing on bottom bar from slot #60

Unit / System 290T818 Unit / System 290T818


Appendix No. 99 Appendix No. 100
Remarks Greasing on top and bottom bar from slot #61 Remarks Greasing on top and bottom bar from slot #61

Page 955 of 1653


Chilca Uno - Greasing on TE side.rev2

Unit / System 290T818 Unit / System 290T818


Appendix No. 101 Appendix No. 102
Remarks Greasing on top and bottom bar from slot #61 Remarks Greasing on top and bottom bar from slot #61

Unit / System 290T818 Unit / System 290T818


Appendix No. 103 Appendix No. 104
Remarks Greasing on top and bottom bar from slot #62 Remarks Greasing on top and bottom bar from slot #62

Unit / System 290T818 Unit / System 290T818


Appendix No. 105 Appendix No. 106
Remarks Greasing on top and bottom bar from slot #62 Remarks Greasing on top and bottom bar from slot #62

Page 956 of 1653


Chilca Uno - Greasing on TE side.rev2

Unit / System 290T818 Unit / System 290T818


Appendix No. 107 Appendix No. 108
Remarks Greasing on top and bottom bar from slot #63 Remarks Greasing on top and bottom bar from slot #63

Unit / System 290T818 Unit / System 290T818


Appendix No. 109 Appendix No. 110
Remarks Greasing on top and bottom bar from slot #63 Remarks Greasing on top and bottom bar from slot #63

Unit / System 290T818 Unit / System 290T818


Appendix No. 111 Appendix No. 112
Remarks Greasing on top and bottom bar from slot #63 Remarks Greasing on top and bottom bar from slot #63

Page 957 of 1653


Chilca Uno - Greasing on TE side.rev2

Unit / System 290T818 Unit / System 290T818


Appendix No. 113 Appendix No. 114
Remarks Greasing on top and bottom bar from slot #63 Remarks Greasing on top and bottom bar from slot #63

Unit / System 290T818 Unit / System 290T818


Appendix No. 115 Appendix No. 116
Remarks Greasing on top and bottom bar from slot #63 Remarks Greasing on top and bottom bar from slot #63

Unit / System 290T818 Unit / System 290T818


Appendix No. 117 Appendix No. 118
Remarks Greasing on top and bottom bar from slot #63 Remarks Greasing on top and bottom bar from slot #63

Page 958 of 1653


Chilca Uno - Greasing on TE side.rev2

Unit / System 290T818 Unit / System 290T818


Appendix No. 119 Appendix No. 120
Remarks Greasing on top and bottom bar from slot #64 Remarks Greasing on top and bottom bar from slot #64

Unit / System 290T818 Unit / System 290T818


Appendix No. 121 Appendix No. 122
Remarks Greasing on top and bottom bar from slot #64 Remarks Greasing on top and bottom bar from slot #64

Unit / System 290T818 Unit / System 290T818


Appendix No. 123 Appendix No. 124
Remarks Greasing on top and bottom bar from slot #64 Remarks Greasing on top and bottom bar from slot #64

Page 959 of 1653


Chilca Uno - Greasing on TE side.rev2

Unit / System 290T818 Unit / System 290T818


Appendix No. 125 Appendix No. 126
Remarks Greasing on top and bottom bar from slot #64 Remarks Greasing on top and bottom bar from slot #64

Unit / System 290T818 Unit / System 290T818


Appendix No. 127 Appendix No. 128
Remarks Greasing on top and bottom bar from slot #65 Remarks Greasing on top and bottom bar from slot #65

Unit / System 290T818 Unit / System 290T818


Appendix No. 129 Appendix No. 130
Remarks Greasing on top and bottom bar from slot #65 Remarks Greasing on top and bottom bar from slot #65

Page 960 of 1653


Chilca Uno - Greasing on TE side.rev2

Unit / System 290T818 Unit / System 290T818


Appendix No. 131 Appendix No. 132
Remarks Greasing on top bar from slot #66 Remarks Greasing on top bar from slot #66

Unit / System 290T818 Unit / System 290T818


Appendix No. 133 Appendix No. 134
Remarks Greasing on top bar from slot #66 Remarks Greasing on top bar from slot #66

Unit / System 290T818 Unit / System 290T818


Appendix No. 135 Appendix No. 136
Remarks Greasing on top bar from slot #67 Remarks Greasing on top bar from slot #67

Page 961 of 1653


Chilca Uno - Greasing on TE side.rev2

Unit / System 290T818 Unit / System 290T818


Appendix No. 137 Appendix No. 138
Remarks Greasing on top bar from slot #68 Remarks Greasing on top bar from slot #68

Unit / System 290T818 Unit / System 290T818


Appendix No. 139 Appendix No. 140
Remarks Greasing on top bar from slot #68 Remarks Greasing on top bar from slot #68

Unit / System 290T818 Unit / System 290T818


Appendix No. 141 Appendix No. 142
Remarks Greasing on top bar from slot #68 Remarks Greasing on top bar from slot #68

Page 962 of 1653


Chilca Uno - Greasing on TE side.rev2

Unit / System 290T818 Unit / System 290T818


Appendix No. 143 Appendix No. 144
Remarks Greasing on top bar from slot #69 Remarks Greasing on top bar from slot #69

Unit / System 290T818 Unit / System 290T818


Appendix No. 145 Appendix No. 146
Remarks Side ripple spring on bar from slot #69 Remarks Greasing on top bar from slot #69

Unit / System 290T818 Unit / System 290T818


Appendix No. 147 Appendix No. 148
Remarks Greasing on top bar from slot #70 Remarks Greasing on top bar from slot #71

Page 963 of 1653


Chilca Uno - Greasing on TE side.rev2

Unit / System 290T818 Unit / System 290T818


Appendix No. 149 Appendix No. 150
Remarks Greasing on top bar from slot #71 Remarks Greasing on top bar from slot #71

Unit / System 290T818 Unit / System 290T818


Appendix No. 151 Appendix No. 152
Remarks Greasing on top bar from slot #72 Remarks Greasing on top bar from slot #72

Unit / System 290T818 Unit / System 290T818


Appendix No. 153 Appendix No. 154
Remarks Greasing on top bar from slot #72 Remarks Greasing on top bar from slot #72

Page 964 of 1653


Chilca Uno - Greasing on TE side.rev2

Unit / System 290T818 Unit / System 290T818


Appendix No. 155 Appendix No. 156
Remarks Greasing on top bar from slot #72 Remarks Greasing on top bar from slot #72

Page 965 of 1653


GE Power Power Services

4.3 Stator As-Found Electical Testing


Resistance
Winding
Armature
CATEGORY4.3.1
4.3.1 Armature Winding Resistance
FORM
Part Condition: Good
Part Description:
Winding resistances were taken with a Digital Low Resistance Ohm Meter (DLRO) to obtain
the desired accuracy in the low resistance ranges associated with stator windings. No
differences were observed in the copper resistance of the stator phases. The spread of
copper resistance readings between the phases should be within 1% and/ or when
comparing to factory test results, each phase should be within +/- 2% of the original factory
measurement for that phase. The winding resistance results were found to be satisfactory.

270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 966 of 1653
D3162041 Armature Winding Resista…

Armature Winding Resistance


Equip Code 324 Dual Terminal - TE
Date (m/d/y) 01/16/2021 Turbine Serial No. 270T818 Prepared by Marina Anders
Generator Serial No. 290T818 ERP Project ID 10339092

Applicable Figure FIG 6 A B C D E F


Terminal Position In Figure T3 T2 T1 T6 T5 T4

Terminal Labels Left Center Right Line or Neutral Terminals


Turbine End T6 T5 T4 Neutral Terminals
Collector End T3 T2 T1 Line Terminals
Customer Designation
Resistance 0.000918 0.000920 0.000919 Temp ºC 24.5
Resistance Corrected to 25ºC 0.000920 0.000922 0.000921 24.5
Factory Resistance at 25ºC 0.000900 0.000900 0.000900 Fact. Or Calc. Selection Factory
Prior Test Correct to 25ºC Date (mm/dd/yy)
Test Equipment Information Rule A B C
Serial No. of Equipment 101880611 1 Pass
Calibration date 8/6/2020 2
Calibration Due Date 8/7/2021 3 Pass Pass Pass
4 NA NA NA
Rules:
1. The spread of copper resistance readings between the phases should be within 1%.
2. When comparing to historical test results each phase should be within +/- 1% of the previous
reading for that phase.
3. When comparing to factory test results, each phase should be within +/- 2% of the original factory
measurement for that phase.
4. When comparing to calculated values, each phase should be within +/- 5% of the calculated
resistance for that phase.

Comments

GE Proprietary and Confidential Information. Not to be distributed or reproduced to third parties without prior GE approval
D3162041 Sheet: (a) Rev 2.2 - 03/11/2020

Page 967 of 1653


GE Power Power Services
Test
(PI)
Index
Polarization
with
Resistance
Insulation
Armature
4.3.2
4.3.2 Armature Insulation Resistance with Polarization
Index (PI) Test
FORM
Part Description:
The purpose of this test is to determine the integrity of the insulation system. Insulation
Resistance at Left and Right phases show a good insulation system if values over 1GOhm in
the 1º minute Plus, the PI was greater than 2 on those phases. Although, center phase
failed the test presenting both low Polarization Index and low MOhm absolute value.

270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 968 of 1653
D3162043 Stator Winding IR and HV Proof…
Stator Winding Insulation Resistance / HV Proof Tests
Generator Test & Inspection
Date 16/01/2021 Generator No.: 290T818 Prepared by: Renan Lopes
Equipment 324 Marina Anders
OEM GE Stator Voltage (kV): 18.0 Project ID: 10339092
DC INSULATION RESISTANCE (Megohms) per TM2030
Voltage: 5000 Volts
10 Minute Insulation Resistance
Time(Min) Left (CE) Center (CE) Right (CE)
0.5 525 360 968
1.0 1668 419 1775 12000
2.0 2820 460 2970
3.0 3970 480 3900 10000
4.0 4950 494 4870
5.0 5980 503 5650 M
E 8000
6.0 6970 510 6600
G
7.0 7950 515 7300 O
8.0 9120 518 8140 H 6000
9.0 9870 520 8560 M
S
10.0 10660 524 9220 4000
PI 6.4 1.3 5.2
Rule 1 PASS FAIL PASS
2000
Rule 2 PASS FAIL PASS
After Hipot1 min
0
Rule 3
0.0 2.0 4.0 6.0 8.0 10.0 12.0
TIME (Min.)
Conditions During Insulation Resistance
o
Winding Temperature ( C) 26 Left (CE) Center (CE) Right (CE)
Ambient Tempature (oC) 23
Relative Humidity (%) 69%
Insulation Type Thermal Setting (i.e. Micapal, Isotenax, >1960)
Corrected Resistance1 minute at 40°C IEC 60034-27 Left (CE) 1668 Center (CE) 419 Right (CE) 1775 Megohms
HIGH VOLTAGE PROOF TEST per TM2050
Test Series DC Recommended Test Voltage Actual Test Voltage
Stator Voltage 18.0 kV DC 45.9 kV DC kV
NOTES 1.) Prior to any high voltage testing, fill in D316218 and get customer agreement on test voltages.
2.) For DC, the test is performed at the end of the DC Leakage Test, use D3162044.
3.) For AC, record results below.
AC HIPOT RESULTS Left (CE) Center (CE) Right (CE) Conditions During HV Proof Test
Passed test at (kV) - 1 min. Winding Temperature (oC)
Failed test at [kV/Time(sec)] Ambient Temperature (oC)
Excitation Voltage (Volts) Relative Humidity (%)
Current (Amps)
Instrument Description ID No. CAL Exp. Date COMMENTS
Megger (MEGOhmeter) 101343997 08/07/2021

GE Proprietary and Confidential Information. Not to be distributed or reproduced to third parties without prior GE approval
D3162043 Sheet: (a) Rev 2.1 - 08/05/2020

Page 969 of 1653


GE Power Power Services
Test
RTD
4.3.3
4.3.3 RTD Test
FORM
Part Description:
All the RTD’s were tested in the generator terminal box. It was checked resistance in each
RTD and megger with 500Vdc (value tested in prior test). The results were accepted and
nothing inadmissible was detected during the test.

Below you can find the test results

270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 970 of 1653
D316403 RTD Test Dual Element

RTD Test
Dual Element - Copper, Nickel, Platinum or Special
Date 2/24/21 Generator Serial No. 290T818 Prepared By Marília Oliveira
Erica Koono
Turbine Serial No. 270T818 Project ID C-10339092
Test Article Reference: TM2010

Winding Temperature: 42 ºC

Device: Fluke 287


Type must be entered as follows: C, N, P or O. *See Note below.
RTD RTD RESISTANCE Indicated Customer
Remarks
No. Type* AB AC BC (AB+AC)/2 - BC Temp. ºC Temp ºC
1 P 117.27 117.32 1.45 115.85 41.16 SLOT 1 - TE
1' P 117.25 117.27 1.46 115.80 41.04 SLOT 1 - TE
2 P 118.24 118.27 1.50 116.76 43.52 SLOT 25 - TE
2' P 118.26 118.26 1.51 116.75 43.51 SLOT 25 - TE
3 P 116.77 116.78 1.22 115.56 40.40 SLOT 49 - TE
3' P 116.88 116.88 1.22 115.66 40.68 SLOT 49 - TE
4 P 116.47 116.44 0.96 115.50 40.25 SLOT 13 - CE
4' P 116.47 116.46 0.96 115.51 40.27 SLOT 13 - CE
5 P 116.07 116.08 0.75 115.33 39.81 SLOT 37 - CE
5' P 116.05 116.03 0.75 115.29 39.71 SLOT 37 - CE
6 P 115.50 115.46 0.74 114.74 38.29 SLOT 61 - CE
6' P 115.55 115.56 0.76 114.80 38.43 SLOT 61 - CE
7
7'
8
8'
9
9'
10
10'
11
11'
12
12'
*RTD Type must be entered as: C, N, P or O O = User Defined RTD Characteristics
Standard RTDs Material Name =
C = Copper 10 Ω @ 25 ºC Reference Resistance RREF = ohms
N = Nickel 120 Ω @ 0 ºC Reference Temperature TREF = ºC
P = Platinum 100 Ω @ 0 ºC (DIN Standard) Coefficient of resistance (α) =
Non-Standard RTDs ohms per ohm /per ºC
O = User defined as described at right RTD Information Source
Megger SN: 101343997 Calibration Date: 6/8/20 Due Date: 7/8/21
Fluke SN: 40380007 Calibration Date: 6/8/20 Due Date: 7/8/21

GE Proprietary and Confidential Information. Not to be distributed or reproduced to third parties without prior GE approval
D316403 Sheet: 1 thru 12 Rev 3.1 - 05/15/2020

Page 971 of 1653


D316403 RTD Test Dual Element

RTD Test
Dual Element - Copper, Nickel, Platinum or Special
Date 2/24/21 Generator Serial No. 290T818 Prepared By Marília Oliveira
Erica Koono
Turbine Serial No. 270T818 Project ID C-10339092

Winding Temperature: 42 ºC
Device: Fluke 287
Type must be entered as follows: C, N, P or O. *See Note below.
RTD RTD RESISTANCE Indicated Customer
Remarks
No. Type* AB AC BC (AB+AC)/2 - BC Temp. ºC Temp ºC
13
13'
14
14'
15
15'
16
16'
17
17'
18
18'
19
19'
20 P 119.13 119.13 1.94 117.19 44.65 SLOT 14 - CENTER/TE
20' P 119.20 119.20 1.99 117.21 44.70 SLOT 14 - CENTER/TE
21 P 118.78 118.75 1.69 117.08 44.35 SLOT 38 - CENTER/TE
21' P 118.68 118.70 1.70 116.99 44.13 SLOT 38 - CENTER/TE
22 P 118.00 117.99 1.72 116.28 42.27 SLOT 62 - CENTER/TE
22' P 117.99 117.97 1.75 116.23 42.16 SLOT 62 - CENTER/TE
23
23'
24
24'
*RTD Type must be entered as: C, N, P or O O = User Defined RTD Characteristics
Standard RTDs Material Name =
C = Copper 10 Ω @ 25 ºC Reference Resistance RREF = ohms
N = Nickel 120 Ω @ 0 ºC Reference Temperature TREF = ºC
P = Platinum 100 Ω @ 0 ºC (DIN Standard) Coefficient of resistance (α) =
Non-Standard RTDs ohms per ohm /per ºC
O = User defined as described at right RTD Information Source
Megger SN: 101343997 Calibration Date: 6/8/20 Due Date: 7/8/21
Fluke SN: 40380007 Calibration Date: 6/8/20 Due Date: 7/8/21

GE Proprietary and Confidential Information. Not to be distributed or reproduced to third parties without prior GE approval
D316403 Sheet: 13 thru 24 Rev 3.1 - 05/15/2020

Page 972 of 1653


D316403 RTD Test Dual Element

RTD Test
Dual Element - Copper, Nickel, Platinum or Special
Date 2/24/21 Generator Serial No. 290T818 Prepared By Marília Oliveira
Erica Koono
Turbine Serial No. 270T818 Project ID C-10339092

Winding Temperature: 42 ºC
Device: Fluke 287
Type must be entered as follows: C, N, P or O. *See Note below.
RTD RTD RESISTANCE Indicated Customer
Remarks
No. Type* AB AC BC (AB+AC)/2 - BC Temp. ºC Temp ºC
25
25'
26
26'
27
27'
28
28'
29
29'
30
30'
31 P 118.53 118.61 1.89 116.68 43.32 SLOT 2 - CENTER/TE
31' P 118.47 118.49 1.82 116.66 43.27 SLOT 2 - CENTER/TE
32 P 119.40 119.41 1.94 117.47 45.36 SLOT 26 - CENTER/TE
32' P 119.43 119.40 1.91 117.51 45.47 SLOT 26 - CENTER/TE
33 P 118.00 118.01 1.58 116.43 42.66 SLOT 50 - CENTER/TE
33' P 117.96 117.96 1.58 116.38 42.55 SLOT 50 - CENTER/TE
34 P 117.41 117.41 1.18 116.23 42.16 SLOT 3 - CENTER/CE
34' P 117.40 117.39 1.17 116.23 42.14 SLOT 3 - CENTER/CE
35 P 117.01 116.99 1.06 115.94 41.40 SLOT 27 - CENTER/CE
35' P 118.48 118.46 1.22 117.25 44.81 SLOT 27 - CENTER/CE
36 P 118.38 118.38 1.21 117.17 44.60 SLOT 51 - CENTER/CE
36' P 116.95 116.96 1.00 115.96 41.44 SLOT 51 - CENTER/CE
*RTD Type must be entered as: C, N, P or O O = User Defined RTD Characteristics
Standard RTDs Material Name =
C = Copper 10 Ω @ 25 ºC Reference Resistance RREF = ohms
N = Nickel 120 Ω @ 0 ºC Reference Temperature TREF = ºC
P = Platinum 100 Ω @ 0 ºC (DIN Standard) Coefficient of resistance (α) =
Non-Standard RTDs ohms per ohm /per ºC
O = User defined as described at right RTD Information Source
Megger SN: 101343997 Calibration Date: 6/8/20 Due Date: 7/8/21
Fluke SN: 40380007 Calibration Date: 6/8/20 Due Date: 7/8/21

GE Proprietary and Confidential Information. Not to be distributed or reproduced to third parties without prior GE approval
D316403 Sheet: 25 thru 36 Rev 3.1 - 05/15/2020

Page 973 of 1653


D316403 RTD Test Dual Element

RTD Test
Dual Element - Copper, Nickel, Platinum or Special
Date 2/24/21 Generator Serial No. 290T818 Prepared By Marília Oliveira
Erica Koono
Turbine Serial No. 270T818 Project ID C-10339092

RTD INSULATION RESISTANCE TEST RESULTS (MEGOHMS)


RTD INSULATION RESISTANCE (MEGOHMS) @ 500 Volts DC
# 1 thru # 22 = 5280.00 megohms
# 31 thru # 36 = 7830.00 megohms
# thru # = megohms
# thru # = megohms
# thru # = megohms
# thru # = megohms
# thru # = megohms
# thru # = megohms
# thru # = megohms
# thru # = megohms
# thru # = megohms
# thru # = megohms
# thru # = megohms
# thru # = megohms
# thru # = megohms
# thru # = megohms
# thru # = megohms
# thru # = megohms
# thru # = megohms
# thru # = megohms
# thru # = megohms
# thru # = megohms
# thru # = megohms
# thru # = megohms
# thru # = megohms

Megger SN: 101343997 Calibration Date: 6/8/20 Due Date: 7/8/21


Fluke SN: 40380007 Calibration Date: 6/8/20 Due Date: 7/8/21

GE Proprietary and Confidential Information. Not to be distributed or reproduced to third parties without prior GE approval
D316403 Sheet: RTD Megger Rev 3.1 - 05/15/2020

Page 974 of 1653


GE Power Power Services
test
Bump
4.3.4
4.3.4 Bump test
FORM
Part Condition: Fair
Part Description:
As part of the TIL 1965 , it was recommended to perform an Endwinding Bump test. This
test was performed by the GE LES (Life Extension Services) team using a certified
equipment. The response for phase connection number CEPCBR001, CEPCBT001,
CEPCBR003, CEPCBR013, CEPCBT013, CEPCBT025, CEPCBR037, CEPCTT050,
CEPCBT051, and CEPCBR063 exceeded the threshold listed in table 1 of Appendix A on
RR Inspection report.

270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 975 of 1653
Bump Test_As Found

GE Power Inspection & Life Extension Services


Endwinding Vibration Test Report

Engie Energia Peru Sa


Chilca Uno Power Station
ST1 (290T818)
Endwinding Vibration Test Report

Prepared for: Engie Energia Peru Sa


Site: Chilca Uno
Unit No: ST1
Location: Lima, Peru
Generator S/N: 290T818
Turbine S/N: 270T818
Test No: 1
Job No: 10339092#Main 2.1
Date of test: January 19, 2021
Test performed by: Wesley Ihlow

GE Proprietary Information. This document contains proprietary information of the General Electric Company and
may not be used or disclosed to others, except with the written permission of General Electric Company. 1

Page 976 of 1653


Bump Test_As Found

GE Power Inspection & Life Extension Services


Endwinding Vibration Test Report

EXECUTIVE SUMMARY

This report contains results from a modal impact (bump) test on the end winding series loops and
phase connections of ST1 a GE generator S/N 290T818 at the Chilca Uno site in Lima, Peru on
January 19, 2021. An instrumented hammer was used to excite the generator components while an
accelerometer measured the response. Data was analyzed with a spectrum analyzer in real time and
the frequency response functions, in g/lb were obtained on both the turbine end (TE) and collector
end (CE) series loops and phase connections.

Appendix A Table 1 contain the acceptance criteria.


Appendix B Enclosures 1 through 3 contain the data plotted as a transfer function (Amplitude versus
Frequency).

TEST RESULTS AND SUMMARY OF ANALYSIS

The turbine end series loop axial, radial, and tangential responses were acceptable and found within
limits. Plots of the data are shown in Enclosure 1 of Appendix B.

The collector end series loop axial, radial, and tangential responses were acceptable and found within
limits. Plots of the data are shown in Enclosure 2 of Appendix B.

The response for phase connection number CEPCBR001, CEPCBT001, CEPCBR003, CEPCBR013,
CEPCBT013, CEPCBT025, CEPCBR037, CEPCTT050, CEPCBT051, and CEPCBR063 exceeded the threshold
listed in table 1 of Appendix A. All other phase connection responses were acceptable and found within
limits. Plots of the data are shown in Enclosure 3 of Appendix B.

GE Proprietary Information. This document contains proprietary information of the General Electric Company and
may not be used or disclosed to others, except with the written permission of General Electric Company. 2

Page 977 of 1653


Bump Test_As Found

GE Power Inspection & Life Extension Services


Endwinding Vibration Test Report

CONCLUSIONS AND RECOMMENDATIONS


Threshold limits exceed the acceptance criteria established by GE for the unit tested. Generator
Service Engineering should be contacted for a resolution and/or disposition.

EQUIPMENT USED

PCB Model 338C04 Accelerometer, S/N 6045 and calibration due date 13AUG2021
PCB Model 086D20 Impact Hammer, S/N 20552 and calibration due date 13AUG2021
OROS OR24 4 Channel PC Based Spectrum Analyzer, S/N 008071 and calibration due date 12AUG2021

TEST OVERVIEW

An end winding vibration “bump” test is performed to determine the fundamental resonant frequency
and associated response value of the individual series loops and phase connections of a generator.
Data related to series loops and phase connections, which exceed current GE criteria, is relayed to GE
Generator Engineering where the results of these tests are analyzed to determine whether additional
support is required. Data related to series loops and phase connections, which appear around 60 and
120 Hz (or 50 and 100 Hz) will be relayed to site personnel for other OEM units.

TERMINOLOGY (SERIES LOOPS AND PHASE CONNECTIONS DATA PLOTS PER LOCATION)
(Appendix B Enclosures 1 through 3)

The left plot for each measurement location and direction is scaled with a frequency range of 0 to 200
Hz. The right plot is scaled for a range of [55 to 140] Hz and includes a horizontal amplitude line
identifying the engineering pass/fail threshold. At the upper left of each trace is a file name identifying
the measurement location and direction. The terminology used for Series Loops and Phase Connection
Data Plots per location is the following:

CEPCBT001.UFF
| | | | | --------------- Bar Number (1 to 72)
| | | | ----------------- A = Axial Direction, R = Radial Direction, T = Tangential Direction
| | | ------------------- B = Bottom Phase Connection; T = Top Phase Connection
| | ---------------------- PC = Phase Connection (No designation for Series Loops)
|-------------------------- CE = Collector End; TE = Turbine End

GE Proprietary Information. This document contains proprietary information of the General Electric Company and
may not be used or disclosed to others, except with the written permission of General Electric Company. 3

Page 978 of 1653


Bump Test_As Found

GE Power Inspection & Life Extension Services


Endwinding Vibration Test Report

APPENDIX A
Acceptance Criteria

(Test data was compared to the amplitude threshold criteria outlined in table 1)

GE Proprietary Information. This document contains proprietary information of the General Electric Company and
may not be used or disclosed to others, except with the written permission of General Electric Company. 4

Page 979 of 1653


Bump Test_As Found

GE Power Inspection & Life Extension Services


Endwinding Vibration Test Report

Table 1: Acceptance criteria for GE conventionally-cooled 324 generator resonance testing (2 pole, 60
Hz), Repair Engineering Instruction 503HA422 – 324 End Winding Blocking Upgrades

Series Loop
Measurement Phase Connection Applicable Frequency
Direction Threshold Threshold Range
Axial 0.5 g / lb 0.5 g / lb 55-70 Hz & 110-140 Hz
Radial 0.5 g / lb 0.5 g/ lb 55-70 Hz & 110-140 Hz
Tangential 0.5 g / lb 0.5 g / lb 55-70 Hz & 110-140 Hz

GE Proprietary Information. This document contains proprietary information of the General Electric Company and
may not be used or disclosed to others, except with the written permission of General Electric Company. 5

Page 980 of 1653


Bump Test_As Found

GE Power Inspection & Life Extension Services


Endwinding Vibration Test Report

APPENDIX B
Test Data Plots
(Amplitude versus Frequency)

GE Proprietary Information. This document contains proprietary information of the General Electric Company and
may not be used or disclosed to others, except with the written permission of General Electric Company. 6

Page 981 of 1653


Bump Test_As Found

GE Power Inspection & Life Extension Services


Endwinding Vibration Test Report

Enclosure 1
Turbine End Series Loop Frequency Responses
(Amplitude versus Frequency)

GE Proprietary Information. This document contains proprietary information of the General Electric Company and
may not be used or disclosed to others, except with the written permission of General Electric Company. 7

Page 982 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA001 1 - 55 Hz, 0.0018 g/lbf PASS


1 - 122.5 Hz, 0.0217 g/lbf 2 - 70 Hz, 0.0007 g/lbf
2 - 185.0 Hz, 0.0196 g/lbf 3 - 110 Hz, 0.0047 g/lbf
3 - 188.5 Hz, 0.0187 g/lbf 4 - 140 Hz, 0.0022 g/lbf
40m 500m

400m
30m

1 300m
Amplitude g/lbf

Amplitude g/lbf
23
20m
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER001 1 - 55 Hz, 0.0050 g/lbf PASS


1 - 97.5 Hz, 0.0447 g/lbf 2 - 70 Hz, 0.0029 g/lbf
2 - 65.5 Hz, 0.0388 g/lbf 3 - 110 Hz, 0.0033 g/lbf
3 - 131.5 Hz, 0.0281 g/lbf 4 - 140 Hz, 0.0053 g/lbf
50m 500m
1

40m 2 400m

30m 3 300m
Amplitude g/lbf

Amplitude g/lbf

20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET001 1 - 55 Hz, 0.0024 g/lbf PASS


1 - 186.0 Hz, 0.0577 g/lbf 2 - 70 Hz, 0.0029 g/lbf
2 - 159.5 Hz, 0.0373 g/lbf 3 - 110 Hz, 0.0131 g/lbf
3 - 155.5 Hz, 0.0356 g/lbf 4 - 140 Hz, 0.0161 g/lbf
80m 500m

400m
60m 1

300m
Amplitude g/lbf

Amplitude g/lbf

40m 32
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 983 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA002 1 - 55 Hz, 0.0019 g/lbf PASS


1 - 184.5 Hz, 0.0245 g/lbf 2 - 70 Hz, 0.0007 g/lbf
2 - 122.5 Hz, 0.0207 g/lbf 3 - 110 Hz, 0.0052 g/lbf
3 - 189.0 Hz, 0.0145 g/lbf 4 - 140 Hz, 0.0020 g/lbf
40m 500m

400m
30m
1
300m
Amplitude g/lbf

Amplitude g/lbf
2
20m
3 200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER002 1 - 55 Hz, 0.0047 g/lbf PASS


1 - 65.5 Hz, 0.0411 g/lbf 2 - 70 Hz, 0.0026 g/lbf
2 - 97.5 Hz, 0.0357 g/lbf 3 - 110 Hz, 0.0036 g/lbf
3 - 99.0 Hz, 0.0349 g/lbf 4 - 140 Hz, 0.0048 g/lbf
50m 500m
1
40m 400m
23

30m 300m
Amplitude g/lbf

Amplitude g/lbf

20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET002 1 - 55 Hz, 0.0020 g/lbf PASS


1 - 185.5 Hz, 0.0549 g/lbf 2 - 70 Hz, 0.0025 g/lbf
2 - 159.5 Hz, 0.0334 g/lbf 3 - 110 Hz, 0.0113 g/lbf
3 - 158.0 Hz, 0.0319 g/lbf 4 - 140 Hz, 0.0136 g/lbf
80m 500m

400m
60m 1

300m
Amplitude g/lbf

Amplitude g/lbf

40m
32
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 984 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA003 1 - 55 Hz, 0.0019 g/lbf PASS


1 - 184.5 Hz, 0.0333 g/lbf 2 - 70 Hz, 0.0011 g/lbf
2 - 122.5 Hz, 0.0257 g/lbf 3 - 110 Hz, 0.0057 g/lbf
3 - 188.5 Hz, 0.0151 g/lbf 4 - 140 Hz, 0.0033 g/lbf
40m 500m
1
400m
30m
2
300m
Amplitude g/lbf

Amplitude g/lbf
20m
3 200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER003 1 - 55 Hz, 0.0047 g/lbf PASS


1 - 99.0 Hz, 0.0489 g/lbf 2 - 70 Hz, 0.0029 g/lbf
2 - 65.5 Hz, 0.0449 g/lbf 3 - 110 Hz, 0.0032 g/lbf
3 - 131.5 Hz, 0.0372 g/lbf 4 - 140 Hz, 0.0046 g/lbf
1
50m 500m
2

40m 3 400m

30m 300m
Amplitude g/lbf

Amplitude g/lbf

20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET003 1 - 55 Hz, 0.0031 g/lbf PASS


1 - 185.5 Hz, 0.0614 g/lbf 2 - 70 Hz, 0.0036 g/lbf
2 - 155.0 Hz, 0.0402 g/lbf 3 - 110 Hz, 0.0160 g/lbf
3 - 159.0 Hz, 0.0390 g/lbf 4 - 140 Hz, 0.0188 g/lbf
200m 500m

400m

300m
Amplitude g/lbf

Amplitude g/lbf

100m
200m
1
23
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 985 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA004 1 - 55 Hz, 0.0017 g/lbf PASS


1 - 122.0 Hz, 0.0243 g/lbf 2 - 70 Hz, 0.0012 g/lbf
2 - 184.0 Hz, 0.0227 g/lbf 3 - 110 Hz, 0.0070 g/lbf
3 - 189.0 Hz, 0.0155 g/lbf 4 - 140 Hz, 0.0030 g/lbf
40m 500m

400m
30m
1
2 300m
Amplitude g/lbf

Amplitude g/lbf
20m
3
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER004 1 - 55 Hz, 0.0049 g/lbf PASS


1 - 99.0 Hz, 0.0633 g/lbf 2 - 70 Hz, 0.0026 g/lbf
2 - 65.5 Hz, 0.0471 g/lbf 3 - 110 Hz, 0.0031 g/lbf
3 - 131.5 Hz, 0.0369 g/lbf 4 - 140 Hz, 0.0044 g/lbf
80m 500m

1
400m
60m
2
300m
Amplitude g/lbf

Amplitude g/lbf

40m 3
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET004 1 - 55 Hz, 0.0020 g/lbf PASS


1 - 186.5 Hz, 0.0391 g/lbf 2 - 70 Hz, 0.0017 g/lbf
2 - 163.5 Hz, 0.0265 g/lbf 3 - 110 Hz, 0.0101 g/lbf
3 - 155.5 Hz, 0.0233 g/lbf 4 - 140 Hz, 0.0106 g/lbf
100m 500m

400m

300m
Amplitude g/lbf

Amplitude g/lbf

50m
1
200m
2
3
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 986 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA005 1 - 55 Hz, 0.0020 g/lbf PASS


1 - 122.5 Hz, 0.0238 g/lbf 2 - 70 Hz, 0.0011 g/lbf
2 - 184.0 Hz, 0.0215 g/lbf 3 - 110 Hz, 0.0051 g/lbf
3 - 188.5 Hz, 0.0173 g/lbf 4 - 140 Hz, 0.0028 g/lbf
40m 500m

400m
30m
1
2 300m
Amplitude g/lbf

Amplitude g/lbf
20m 3
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER005 1 - 55 Hz, 0.0044 g/lbf PASS


1 - 99.0 Hz, 0.0599 g/lbf 2 - 70 Hz, 0.0020 g/lbf
2 - 133.5 Hz, 0.0447 g/lbf 3 - 110 Hz, 0.0050 g/lbf
3 - 157.5 Hz, 0.0405 g/lbf 4 - 140 Hz, 0.0042 g/lbf
80m 500m

1 400m
60m

2 300m
Amplitude g/lbf

Amplitude g/lbf

3
40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET005 1 - 55 Hz, 0.0020 g/lbf PASS


1 - 186.0 Hz, 0.0642 g/lbf 2 - 70 Hz, 0.0017 g/lbf
2 - 159.5 Hz, 0.0319 g/lbf 3 - 110 Hz, 0.0102 g/lbf
3 - 163.5 Hz, 0.0282 g/lbf 4 - 140 Hz, 0.0125 g/lbf
200m 500m

400m

300m
Amplitude g/lbf

Amplitude g/lbf

100m
200m
1

23 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 987 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA006 1 - 55 Hz, 0.0020 g/lbf PASS


1 - 185.5 Hz, 0.0253 g/lbf 2 - 70 Hz, 0.0013 g/lbf
2 - 122.5 Hz, 0.0252 g/lbf 3 - 110 Hz, 0.0066 g/lbf
3 - 189.0 Hz, 0.0195 g/lbf 4 - 140 Hz, 0.0041 g/lbf
40m 500m

400m
30m
2 1
300m
Amplitude g/lbf

Amplitude g/lbf
20m 3

200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER006 1 - 55 Hz, 0.0047 g/lbf PASS


1 - 99.0 Hz, 0.0564 g/lbf 2 - 70 Hz, 0.0013 g/lbf
2 - 133.5 Hz, 0.0495 g/lbf 3 - 110 Hz, 0.0054 g/lbf
3 - 157.5 Hz, 0.0422 g/lbf 4 - 140 Hz, 0.0043 g/lbf
80m 500m

400m
60m 1
2
300m
Amplitude g/lbf

Amplitude g/lbf

3
40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET006 1 - 55 Hz, 0.0021 g/lbf PASS


1 - 185.5 Hz, 0.0855 g/lbf 2 - 70 Hz, 0.0025 g/lbf
2 - 159.0 Hz, 0.0420 g/lbf 3 - 110 Hz, 0.0135 g/lbf
3 - 155.0 Hz, 0.0351 g/lbf 4 - 140 Hz, 0.0163 g/lbf
200m 500m

400m

300m
Amplitude g/lbf

Amplitude g/lbf

100m 1
200m

32 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 988 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA007 1 - 55 Hz, 0.0020 g/lbf PASS


1 - 185.0 Hz, 0.0250 g/lbf 2 - 70 Hz, 0.0012 g/lbf
2 - 122.0 Hz, 0.0221 g/lbf 3 - 110 Hz, 0.0052 g/lbf
3 - 161.5 Hz, 0.0144 g/lbf 4 - 140 Hz, 0.0044 g/lbf
40m 500m

400m
30m
1
2 300m
Amplitude g/lbf

Amplitude g/lbf
20m
3 200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER007 1 - 55 Hz, 0.0045 g/lbf PASS


1 - 186.5 Hz, 0.0660 g/lbf 2 - 70 Hz, 0.0015 g/lbf
2 - 133.5 Hz, 0.0631 g/lbf 3 - 110 Hz, 0.0087 g/lbf
3 - 163.0 Hz, 0.0464 g/lbf 4 - 140 Hz, 0.0041 g/lbf
80m 500m
1
2
400m
60m
3 300m
Amplitude g/lbf

Amplitude g/lbf

40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET007 1 - 55 Hz, 0.0033 g/lbf PASS


1 - 185.0 Hz, 0.0757 g/lbf 2 - 70 Hz, 0.0034 g/lbf
2 - 193.5 Hz, 0.0577 g/lbf 3 - 110 Hz, 0.0153 g/lbf
3 - 159.5 Hz, 0.0504 g/lbf 4 - 140 Hz, 0.0213 g/lbf
200m 500m

400m

300m
Amplitude g/lbf

Amplitude g/lbf

100m
1 200m
2
3
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 989 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA008 1 - 55 Hz, 0.0018 g/lbf PASS


1 - 184.5 Hz, 0.0264 g/lbf 2 - 70 Hz, 0.0011 g/lbf
2 - 122.5 Hz, 0.0201 g/lbf 3 - 110 Hz, 0.0047 g/lbf
3 - 97.5 Hz, 0.0126 g/lbf 4 - 140 Hz, 0.0028 g/lbf
40m 500m

400m
30m
1
300m
Amplitude g/lbf

Amplitude g/lbf
2
20m
200m
3
10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER008 1 - 55 Hz, 0.0039 g/lbf PASS


1 - 186.5 Hz, 0.0669 g/lbf 2 - 70 Hz, 0.0019 g/lbf
2 - 133.5 Hz, 0.0555 g/lbf 3 - 110 Hz, 0.0075 g/lbf
3 - 163.0 Hz, 0.0553 g/lbf 4 - 140 Hz, 0.0054 g/lbf
80m 500m
1
400m
60m 2 3

300m
Amplitude g/lbf

Amplitude g/lbf

40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET008 1 - 55 Hz, 0.0018 g/lbf PASS


1 - 185.5 Hz, 0.0413 g/lbf 2 - 70 Hz, 0.0019 g/lbf
2 - 192.5 Hz, 0.0328 g/lbf 3 - 110 Hz, 0.0093 g/lbf
3 - 160.0 Hz, 0.0307 g/lbf 4 - 140 Hz, 0.0119 g/lbf
80m 500m

400m
60m

300m
Amplitude g/lbf

Amplitude g/lbf

1
40m
3 2
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 990 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA009 1 - 55 Hz, 0.0014 g/lbf PASS


1 - 185.0 Hz, 0.0262 g/lbf 2 - 70 Hz, 0.0010 g/lbf
2 - 122.0 Hz, 0.0193 g/lbf 3 - 110 Hz, 0.0052 g/lbf
3 - 97.5 Hz, 0.0103 g/lbf 4 - 140 Hz, 0.0025 g/lbf
40m 500m

400m
30m
1
300m
Amplitude g/lbf

Amplitude g/lbf
20m 2

200m
3
10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER009 1 - 55 Hz, 0.0036 g/lbf PASS


1 - 185.0 Hz, 0.0578 g/lbf 2 - 70 Hz, 0.0020 g/lbf
2 - 97.5 Hz, 0.0520 g/lbf 3 - 110 Hz, 0.0055 g/lbf
3 - 163.0 Hz, 0.0514 g/lbf 4 - 140 Hz, 0.0063 g/lbf
80m 500m

1 400m
60m
2 3
300m
Amplitude g/lbf

Amplitude g/lbf

40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET009 1 - 55 Hz, 0.0020 g/lbf PASS


1 - 189.5 Hz, 0.0408 g/lbf 2 - 70 Hz, 0.0016 g/lbf
2 - 192.5 Hz, 0.0388 g/lbf 3 - 110 Hz, 0.0084 g/lbf
3 - 186.5 Hz, 0.0385 g/lbf 4 - 140 Hz, 0.0088 g/lbf
50m 500m

1
40m 32 400m

30m 300m
Amplitude g/lbf

Amplitude g/lbf

20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 991 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA010 1 - 55 Hz, 0.0016 g/lbf PASS


1 - 184.5 Hz, 0.0221 g/lbf 2 - 70 Hz, 0.0010 g/lbf
2 - 122.5 Hz, 0.0175 g/lbf 3 - 110 Hz, 0.0037 g/lbf
3 - 97.5 Hz, 0.0116 g/lbf 4 - 140 Hz, 0.0026 g/lbf
40m 500m

400m
30m

1 300m
Amplitude g/lbf

Amplitude g/lbf
20m 2
200m
3
10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER010 1 - 55 Hz, 0.0032 g/lbf PASS


1 - 97.5 Hz, 0.0509 g/lbf 2 - 70 Hz, 0.0015 g/lbf
2 - 185.0 Hz, 0.0435 g/lbf 3 - 110 Hz, 0.0067 g/lbf
3 - 131.0 Hz, 0.0381 g/lbf 4 - 140 Hz, 0.0043 g/lbf
80m 500m

400m
60m
1
2 300m
Amplitude g/lbf

Amplitude g/lbf

40m 3

200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET010 1 - 55 Hz, 0.0024 g/lbf PASS


1 - 189.5 Hz, 0.0638 g/lbf 2 - 70 Hz, 0.0028 g/lbf
2 - 192.0 Hz, 0.0607 g/lbf 3 - 110 Hz, 0.0108 g/lbf
3 - 153.5 Hz, 0.0292 g/lbf 4 - 140 Hz, 0.0158 g/lbf
80m 500m

1
2 400m
60m

300m
Amplitude g/lbf

Amplitude g/lbf

40m
3 200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 992 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA011 1 - 55 Hz, 0.0015 g/lbf PASS


1 - 185.0 Hz, 0.0191 g/lbf 2 - 70 Hz, 0.0010 g/lbf
2 - 122.0 Hz, 0.0166 g/lbf 3 - 110 Hz, 0.0038 g/lbf
3 - 174.5 Hz, 0.0092 g/lbf 4 - 140 Hz, 0.0027 g/lbf
20m 1 500m
2
400m
15m

300m
Amplitude g/lbf

Amplitude g/lbf
10m 3
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER011 1 - 55 Hz, 0.0036 g/lbf PASS


1 - 97.5 Hz, 0.0528 g/lbf 2 - 70 Hz, 0.0014 g/lbf
2 - 131.5 Hz, 0.0436 g/lbf 3 - 110 Hz, 0.0084 g/lbf
3 - 65.0 Hz, 0.0416 g/lbf 4 - 140 Hz, 0.0019 g/lbf
80m 500m

400m
60m
1
2 300m
Amplitude g/lbf

Amplitude g/lbf

3
40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET011 1 - 55 Hz, 0.0016 g/lbf PASS


1 - 189.5 Hz, 0.0421 g/lbf 2 - 70 Hz, 0.0018 g/lbf
2 - 192.0 Hz, 0.0403 g/lbf 3 - 110 Hz, 0.0075 g/lbf
3 - 153.5 Hz, 0.0214 g/lbf 4 - 140 Hz, 0.0102 g/lbf
50m 500m
1
2
40m 400m

30m 300m
Amplitude g/lbf

Amplitude g/lbf

3
20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 993 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA012 1 - 55 Hz, 0.0015 g/lbf PASS


1 - 188.5 Hz, 0.0174 g/lbf 2 - 70 Hz, 0.0009 g/lbf
2 - 186.0 Hz, 0.0170 g/lbf 3 - 110 Hz, 0.0032 g/lbf
3 - 122.0 Hz, 0.0154 g/lbf 4 - 140 Hz, 0.0020 g/lbf
20m 500m
21
3 400m
15m

300m
Amplitude g/lbf

Amplitude g/lbf
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER012 1 - 55 Hz, 0.0029 g/lbf PASS


1 - 97.5 Hz, 0.0410 g/lbf 2 - 70 Hz, 0.0017 g/lbf
2 - 65.0 Hz, 0.0381 g/lbf 3 - 110 Hz, 0.0081 g/lbf
3 - 131.5 Hz, 0.0327 g/lbf 4 - 140 Hz, 0.0025 g/lbf
50m 500m
1
40m 2 400m
3
30m 300m
Amplitude g/lbf

Amplitude g/lbf

20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET012 1 - 55 Hz, 0.0023 g/lbf PASS


1 - 192.0 Hz, 0.0529 g/lbf 2 - 70 Hz, 0.0029 g/lbf
2 - 189.0 Hz, 0.0513 g/lbf 3 - 110 Hz, 0.0113 g/lbf
3 - 186.0 Hz, 0.0483 g/lbf 4 - 140 Hz, 0.0166 g/lbf
80m 500m

400m
60m
21
3
300m
Amplitude g/lbf

Amplitude g/lbf

40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 994 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA013 1 - 55 Hz, 0.0012 g/lbf PASS


1 - 189.0 Hz, 0.0216 g/lbf 2 - 70 Hz, 0.0010 g/lbf
2 - 122.0 Hz, 0.0170 g/lbf 3 - 110 Hz, 0.0044 g/lbf
3 - 103.0 Hz, 0.0089 g/lbf 4 - 140 Hz, 0.0018 g/lbf
40m 500m

400m
30m

1 300m
Amplitude g/lbf

Amplitude g/lbf
20m
2
200m

10m 3
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER013 1 - 55 Hz, 0.0030 g/lbf PASS


1 - 65.0 Hz, 0.0390 g/lbf 2 - 70 Hz, 0.0019 g/lbf
2 - 97.5 Hz, 0.0373 g/lbf 3 - 110 Hz, 0.0074 g/lbf
3 - 99.0 Hz, 0.0344 g/lbf 4 - 140 Hz, 0.0038 g/lbf
80m 500m

400m
60m

300m
Amplitude g/lbf

Amplitude g/lbf

1 2
40m 3
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET013 1 - 55 Hz, 0.0013 g/lbf PASS


1 - 192.0 Hz, 0.0215 g/lbf 2 - 70 Hz, 0.0010 g/lbf
2 - 187.5 Hz, 0.0210 g/lbf 3 - 110 Hz, 0.0064 g/lbf
3 - 154.0 Hz, 0.0184 g/lbf 4 - 140 Hz, 0.0066 g/lbf
40m 500m

400m
30m

21 300m
Amplitude g/lbf

Amplitude g/lbf

20m 3
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 995 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA014 1 - 55 Hz, 0.0012 g/lbf PASS


1 - 189.0 Hz, 0.0233 g/lbf 2 - 70 Hz, 0.0010 g/lbf
2 - 122.0 Hz, 0.0170 g/lbf 3 - 110 Hz, 0.0046 g/lbf
3 - 133.5 Hz, 0.0104 g/lbf 4 - 140 Hz, 0.0020 g/lbf
40m 500m

400m
30m
1 300m
Amplitude g/lbf

Amplitude g/lbf
20m
2
200m
3
10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER014 1 - 55 Hz, 0.0029 g/lbf PASS


1 - 99.0 Hz, 0.0400 g/lbf 2 - 70 Hz, 0.0018 g/lbf
2 - 65.0 Hz, 0.0360 g/lbf 3 - 110 Hz, 0.0085 g/lbf
3 - 97.5 Hz, 0.0331 g/lbf 4 - 140 Hz, 0.0034 g/lbf
50m 500m

1
40m 2 400m
3
30m 300m
Amplitude g/lbf

Amplitude g/lbf

20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET014 1 - 55 Hz, 0.0019 g/lbf PASS


1 - 186.5 Hz, 0.0335 g/lbf 2 - 70 Hz, 0.0012 g/lbf
2 - 192.0 Hz, 0.0299 g/lbf 3 - 110 Hz, 0.0092 g/lbf
3 - 154.0 Hz, 0.0272 g/lbf 4 - 140 Hz, 0.0099 g/lbf
80m 500m

400m
60m

300m
Amplitude g/lbf

Amplitude g/lbf

40m
1
2 200m
3

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 996 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA015 1 - 55 Hz, 0.0014 g/lbf PASS


1 - 188.0 Hz, 0.0251 g/lbf 2 - 70 Hz, 0.0014 g/lbf
2 - 122.0 Hz, 0.0197 g/lbf 3 - 110 Hz, 0.0057 g/lbf
3 - 153.5 Hz, 0.0099 g/lbf 4 - 140 Hz, 0.0031 g/lbf
40m 500m

400m
30m
1
300m
Amplitude g/lbf

Amplitude g/lbf
2
20m
200m
3
10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER015 1 - 55 Hz, 0.0031 g/lbf PASS


1 - 99.0 Hz, 0.0506 g/lbf 2 - 70 Hz, 0.0016 g/lbf
2 - 133.5 Hz, 0.0384 g/lbf 3 - 110 Hz, 0.0069 g/lbf
3 - 185.0 Hz, 0.0347 g/lbf 4 - 140 Hz, 0.0030 g/lbf
80m 500m

400m
60m
1
300m
Amplitude g/lbf

Amplitude g/lbf

40m 2
3
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET015 1 - 55 Hz, 0.0022 g/lbf PASS


1 - 187.0 Hz, 0.0386 g/lbf 2 - 70 Hz, 0.0017 g/lbf
2 - 192.5 Hz, 0.0290 g/lbf 3 - 110 Hz, 0.0098 g/lbf
3 - 191.5 Hz, 0.0284 g/lbf 4 - 140 Hz, 0.0107 g/lbf
50m 500m

40m 1 400m

30m 32 300m
Amplitude g/lbf

Amplitude g/lbf

20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 997 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA016 1 - 55 Hz, 0.0014 g/lbf PASS


1 - 187.0 Hz, 0.0226 g/lbf 2 - 70 Hz, 0.0013 g/lbf
2 - 188.0 Hz, 0.0225 g/lbf 3 - 110 Hz, 0.0048 g/lbf
3 - 122.0 Hz, 0.0195 g/lbf 4 - 140 Hz, 0.0026 g/lbf
40m 500m

400m
30m

12 300m
Amplitude g/lbf

Amplitude g/lbf
20m 3

200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER016 1 - 55 Hz, 0.0034 g/lbf PASS


1 - 99.0 Hz, 0.0592 g/lbf 2 - 70 Hz, 0.0013 g/lbf
2 - 133.0 Hz, 0.0428 g/lbf 3 - 110 Hz, 0.0090 g/lbf
3 - 162.5 Hz, 0.0424 g/lbf 4 - 140 Hz, 0.0025 g/lbf
80m 500m

1 400m
60m

2 3 300m
Amplitude g/lbf

Amplitude g/lbf

40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET016 1 - 55 Hz, 0.0018 g/lbf PASS


1 - 187.0 Hz, 0.0342 g/lbf 2 - 70 Hz, 0.0012 g/lbf
2 - 192.0 Hz, 0.0295 g/lbf 3 - 110 Hz, 0.0081 g/lbf
3 - 154.0 Hz, 0.0200 g/lbf 4 - 140 Hz, 0.0091 g/lbf
50m 500m

40m 400m
1
2
30m 300m
Amplitude g/lbf

Amplitude g/lbf

3
20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 998 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA017 1 - 55 Hz, 0.0014 g/lbf PASS


1 - 186.0 Hz, 0.0212 g/lbf 2 - 70 Hz, 0.0011 g/lbf
2 - 122.5 Hz, 0.0187 g/lbf 3 - 110 Hz, 0.0035 g/lbf
3 - 103.0 Hz, 0.0103 g/lbf 4 - 140 Hz, 0.0018 g/lbf
40m 500m

400m
30m

1 300m
Amplitude g/lbf

Amplitude g/lbf
20m 2
200m
3
10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER017 1 - 55 Hz, 0.0035 g/lbf PASS


1 - 99.0 Hz, 0.0580 g/lbf 2 - 70 Hz, 0.0016 g/lbf
2 - 133.0 Hz, 0.0372 g/lbf 3 - 110 Hz, 0.0078 g/lbf
3 - 163.0 Hz, 0.0331 g/lbf 4 - 140 Hz, 0.0031 g/lbf
80m 500m

1 400m
60m

300m
Amplitude g/lbf

Amplitude g/lbf

40m 2
3
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET017 1 - 55 Hz, 0.0025 g/lbf PASS


1 - 188.0 Hz, 0.0493 g/lbf 2 - 70 Hz, 0.0017 g/lbf
2 - 192.0 Hz, 0.0447 g/lbf 3 - 110 Hz, 0.0099 g/lbf
3 - 155.0 Hz, 0.0257 g/lbf 1 4 - 140 Hz, 0.0127 g/lbf
50m 500m
2

40m 400m

30m 300m
Amplitude g/lbf

Amplitude g/lbf

20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 999 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA018 1 - 55 Hz, 0.0015 g/lbf PASS


1 - 186.0 Hz, 0.0236 g/lbf 2 - 70 Hz, 0.0015 g/lbf
2 - 122.5 Hz, 0.0215 g/lbf 3 - 110 Hz, 0.0059 g/lbf
3 - 175.0 Hz, 0.0106 g/lbf 4 - 140 Hz, 0.0032 g/lbf
40m 500m

400m
30m
1
2 300m
Amplitude g/lbf

Amplitude g/lbf
20m
200m
3
10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER018 1 - 55 Hz, 0.0033 g/lbf PASS


1 - 99.0 Hz, 0.0493 g/lbf 2 - 70 Hz, 0.0016 g/lbf
2 - 131.0 Hz, 0.0354 g/lbf 3 - 110 Hz, 0.0065 g/lbf
3 - 159.5 Hz, 0.0324 g/lbf1 4 - 140 Hz, 0.0026 g/lbf
50m 500m

40m 400m
2
3
30m 300m
Amplitude g/lbf

Amplitude g/lbf

20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET018 1 - 55 Hz, 0.0022 g/lbf PASS


1 - 189.0 Hz, 0.0523 g/lbf 2 - 70 Hz, 0.0021 g/lbf
2 - 192.5 Hz, 0.0516 g/lbf 3 - 110 Hz, 0.0106 g/lbf
3 - 155.0 Hz, 0.0250 g/lbf 4 - 140 Hz, 0.0128 g/lbf
80m 500m

400m
60m
12
300m
Amplitude g/lbf

Amplitude g/lbf

40m
200m
3
20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1000 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA019 1 - 55 Hz, 0.0013 g/lbf PASS


1 - 186.0 Hz, 0.0234 g/lbf 2 - 70 Hz, 0.0011 g/lbf
2 - 122.5 Hz, 0.0206 g/lbf 3 - 110 Hz, 0.0041 g/lbf
3 - 103.0 Hz, 0.0101 g/lbf 4 - 140 Hz, 0.0021 g/lbf
40m 500m

400m
30m
1 300m
Amplitude g/lbf

Amplitude g/lbf
2
20m
200m
3
10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER019 1 - 55 Hz, 0.0034 g/lbf PASS


1 - 159.5 Hz, 0.0553 g/lbf 2 - 70 Hz, 0.0017 g/lbf
2 - 131.0 Hz, 0.0525 g/lbf 3 - 110 Hz, 0.0063 g/lbf
3 - 97.5 Hz, 0.0398 g/lbf 4 - 140 Hz, 0.0023 g/lbf
80m 500m

400m
60m 1
2
300m
Amplitude g/lbf

Amplitude g/lbf

3
40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET019 1 - 55 Hz, 0.0024 g/lbf PASS


1 - 192.5 Hz, 0.0687 g/lbf 2 - 70 Hz, 0.0021 g/lbf
2 - 189.5 Hz, 0.0660 g/lbf 3 - 110 Hz, 0.0103 g/lbf
3 - 155.0 Hz, 0.0266 g/lbf 4 - 140 Hz, 0.0130 g/lbf
80m 500m
1
2
400m
60m

300m
Amplitude g/lbf

Amplitude g/lbf

40m

3 200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1001 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA020 1 - 55 Hz, 0.0013 g/lbf PASS


1 - 122.5 Hz, 0.0227 g/lbf 2 - 70 Hz, 0.0012 g/lbf
2 - 186.0 Hz, 0.0205 g/lbf 3 - 110 Hz, 0.0050 g/lbf
3 - 103.0 Hz, 0.0092 g/lbf 4 - 140 Hz, 0.0018 g/lbf
40m 500m

400m
30m

1 300m
Amplitude g/lbf

Amplitude g/lbf
2
20m
200m

10m 3
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER020 1 - 55 Hz, 0.0034 g/lbf PASS


1 - 159.5 Hz, 0.0567 g/lbf 2 - 70 Hz, 0.0014 g/lbf
2 - 131.0 Hz, 0.0546 g/lbf 3 - 110 Hz, 0.0043 g/lbf
3 - 97.5 Hz, 0.0483 g/lbf 4 - 140 Hz, 0.0023 g/lbf
80m 500m

400m
60m 2 1
3
300m
Amplitude g/lbf

Amplitude g/lbf

40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET020 1 - 55 Hz, 0.0026 g/lbf PASS


1 - 192.0 Hz, 0.1145 g/lbf 2 - 70 Hz, 0.0024 g/lbf
2 - 159.0 Hz, 0.0381 g/lbf 3 - 110 Hz, 0.0132 g/lbf
3 - 155.0 Hz, 0.0371 g/lbf 4 - 140 Hz, 0.0165 g/lbf
200m 500m

400m

1 300m
Amplitude g/lbf

Amplitude g/lbf

100m
200m

32
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1002 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA021 1 - 55 Hz, 0.0016 g/lbf PASS


1 - 122.5 Hz, 0.0249 g/lbf 2 - 70 Hz, 0.0015 g/lbf
2 - 185.5 Hz, 0.0249 g/lbf 3 - 110 Hz, 0.0064 g/lbf
3 - 175.0 Hz, 0.0123 g/lbf 4 - 140 Hz, 0.0034 g/lbf
40m 500m

400m
30m
1 2
300m
Amplitude g/lbf

Amplitude g/lbf
20m
200m
3
10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER021 1 - 55 Hz, 0.0038 g/lbf PASS


1 - 97.5 Hz, 0.0632 g/lbf 2 - 70 Hz, 0.0016 g/lbf
2 - 131.0 Hz, 0.0560 g/lbf 3 - 110 Hz, 0.0043 g/lbf
3 - 159.5 Hz, 0.0508 g/lbf 4 - 140 Hz, 0.0026 g/lbf
80m 500m

1
400m
60m 2
3
300m
Amplitude g/lbf

Amplitude g/lbf

40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET021 1 - 55 Hz, 0.0027 g/lbf PASS


1 - 192.0 Hz, 0.1059 g/lbf 2 - 70 Hz, 0.0024 g/lbf
2 - 189.5 Hz, 0.0956 g/lbf 3 - 110 Hz, 0.0128 g/lbf
3 - 177.0 Hz, 0.0374 g/lbf 4 - 140 Hz, 0.0163 g/lbf
200m 500m

400m

1 300m
Amplitude g/lbf

Amplitude g/lbf

100m 2

200m

3
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1003 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA022 1 - 55 Hz, 0.0015 g/lbf PASS


1 - 122.5 Hz, 0.0232 g/lbf 2 - 70 Hz, 0.0016 g/lbf
2 - 185.0 Hz, 0.0195 g/lbf 3 - 110 Hz, 0.0064 g/lbf
3 - 199.5 Hz, 0.0142 g/lbf 4 - 140 Hz, 0.0037 g/lbf
40m 500m

400m
30m

1 300m
Amplitude g/lbf

Amplitude g/lbf
2
20m
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER022 1 - 55 Hz, 0.0040 g/lbf PASS


1 - 97.5 Hz, 0.0647 g/lbf 2 - 70 Hz, 0.0011 g/lbf
2 - 131.0 Hz, 0.0469 g/lbf 3 - 110 Hz, 0.0052 g/lbf
3 - 184.5 Hz, 0.0463 g/lbf 4 - 140 Hz, 0.0021 g/lbf
80m 500m

1
400m
60m
2 3 300m
Amplitude g/lbf

Amplitude g/lbf

40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET022 1 - 55 Hz, 0.0036 g/lbf PASS


1 - 192.0 Hz, 0.1364 g/lbf 2 - 70 Hz, 0.0040 g/lbf
2 - 186.0 Hz, 0.0902 g/lbf 3 - 110 Hz, 0.0179 g/lbf
3 - 155.5 Hz, 0.0488 g/lbf 4 - 140 Hz, 0.0252 g/lbf
200m 500m

400m
1

300m
Amplitude g/lbf

Amplitude g/lbf

100m 2
200m
3
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1004 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA023 1 - 55 Hz, 0.0015 g/lbf PASS


1 - 122.5 Hz, 0.0228 g/lbf 2 - 70 Hz, 0.0014 g/lbf
2 - 185.0 Hz, 0.0176 g/lbf 3 - 110 Hz, 0.0060 g/lbf
3 - 188.5 Hz, 0.0145 g/lbf 4 - 140 Hz, 0.0026 g/lbf
40m 500m

400m
30m

1 300m
Amplitude g/lbf

Amplitude g/lbf
20m 2
3 200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER023 1 - 55 Hz, 0.0042 g/lbf PASS


1 - 97.5 Hz, 0.0605 g/lbf 2 - 70 Hz, 0.0013 g/lbf
2 - 184.5 Hz, 0.0522 g/lbf 3 - 110 Hz, 0.0054 g/lbf
3 - 133.0 Hz, 0.0515 g/lbf 4 - 140 Hz, 0.0031 g/lbf
80m 500m

1 400m
60m
3 2
300m
Amplitude g/lbf

Amplitude g/lbf

40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET023 1 - 55 Hz, 0.0022 g/lbf PASS


1 - 192.0 Hz, 0.0816 g/lbf 2 - 70 Hz, 0.0022 g/lbf
2 - 185.5 Hz, 0.0521 g/lbf 3 - 110 Hz, 0.0123 g/lbf
3 - 155.5 Hz, 0.0311 g/lbf 4 - 140 Hz, 0.0151 g/lbf
100m 500m

1
400m

300m
Amplitude g/lbf

Amplitude g/lbf

2
50m
200m
3

100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1005 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA024 1 - 55 Hz, 0.0014 g/lbf PASS


1 - 122.5 Hz, 0.0229 g/lbf 2 - 70 Hz, 0.0013 g/lbf
2 - 188.5 Hz, 0.0177 g/lbf 3 - 110 Hz, 0.0061 g/lbf
3 - 185.0 Hz, 0.0166 g/lbf 4 - 140 Hz, 0.0022 g/lbf
40m 500m

400m
30m

1 300m
Amplitude g/lbf

Amplitude g/lbf
20m
32
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER024 1 - 55 Hz, 0.0041 g/lbf PASS


1 - 133.0 Hz, 0.0618 g/lbf 2 - 70 Hz, 0.0015 g/lbf
2 - 97.5 Hz, 0.0573 g/lbf 3 - 110 Hz, 0.0043 g/lbf
3 - 185.0 Hz, 0.0445 g/lbf 4 - 140 Hz, 0.0042 g/lbf
80m 500m

1 400m
60m 2

3 300m
Amplitude g/lbf

Amplitude g/lbf

40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET024 1 - 55 Hz, 0.0015 g/lbf PASS


1 - 192.0 Hz, 0.0518 g/lbf 2 - 70 Hz, 0.0011 g/lbf
2 - 185.5 Hz, 0.0347 g/lbf 3 - 110 Hz, 0.0092 g/lbf
3 - 155.5 Hz, 0.0215 g/lbf 4 - 140 Hz, 0.0093 g/lbf
80m 500m

400m
60m
1
300m
Amplitude g/lbf

Amplitude g/lbf

40m 2
200m
3
20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1006 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA025 1 - 55 Hz, 0.0013 g/lbf PASS


1 - 122.5 Hz, 0.0216 g/lbf 2 - 70 Hz, 0.0011 g/lbf
2 - 184.5 Hz, 0.0157 g/lbf 3 - 110 Hz, 0.0056 g/lbf
3 - 188.5 Hz, 0.0143 g/lbf 4 - 140 Hz, 0.0016 g/lbf
40m 500m

400m
30m

1 300m
Amplitude g/lbf

Amplitude g/lbf
20m
2
3 200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER025 1 - 55 Hz, 0.0041 g/lbf PASS


1 - 133.5 Hz, 0.0626 g/lbf 2 - 70 Hz, 0.0016 g/lbf
2 - 97.5 Hz, 0.0429 g/lbf 3 - 110 Hz, 0.0042 g/lbf
3 - 190.0 Hz, 0.0377 g/lbf 4 - 140 Hz, 0.0053 g/lbf
80m 500m

1
400m
60m

2 300m
Amplitude g/lbf

Amplitude g/lbf

40m 3
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET025 1 - 55 Hz, 0.0016 g/lbf PASS


1 - 192.0 Hz, 0.0393 g/lbf 2 - 70 Hz, 0.0009 g/lbf
2 - 185.5 Hz, 0.0380 g/lbf 3 - 110 Hz, 0.0074 g/lbf
3 - 153.5 Hz, 0.0200 g/lbf 1 4 - 140 Hz, 0.0090 g/lbf
40m 2 500m

400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf

3
20m
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1007 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA026 1 - 55 Hz, 0.0013 g/lbf PASS


1 - 122.5 Hz, 0.0197 g/lbf 2 - 70 Hz, 0.0009 g/lbf
2 - 184.5 Hz, 0.0140 g/lbf 3 - 110 Hz, 0.0053 g/lbf
3 - 188.5 Hz, 0.0131 g/lbf 1 4 - 140 Hz, 0.0013 g/lbf
20m 500m

400m
15m 2
3
300m
Amplitude g/lbf

Amplitude g/lbf
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER026 1 - 55 Hz, 0.0044 g/lbf PASS


1 - 133.5 Hz, 0.0579 g/lbf 2 - 70 Hz, 0.0015 g/lbf
2 - 99.0 Hz, 0.0483 g/lbf 3 - 110 Hz, 0.0045 g/lbf
3 - 159.5 Hz, 0.0407 g/lbf 4 - 140 Hz, 0.0052 g/lbf
80m 500m

1 400m
60m
2
300m
Amplitude g/lbf

Amplitude g/lbf

3
40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET026 1 - 55 Hz, 0.0028 g/lbf PASS


1 - 184.5 Hz, 0.0770 g/lbf 2 - 70 Hz, 0.0022 g/lbf
2 - 191.5 Hz, 0.0477 g/lbf 3 - 110 Hz, 0.0133 g/lbf
3 - 153.5 Hz, 0.0350 g/lbf 4 - 140 Hz, 0.0184 g/lbf
80m 1 500m

400m
60m
2
300m
Amplitude g/lbf

Amplitude g/lbf

40m 3
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1008 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA027 1 - 55 Hz, 0.0013 g/lbf PASS


1 - 188.5 Hz, 0.0198 g/lbf 2 - 70 Hz, 0.0010 g/lbf
2 - 122.5 Hz, 0.0191 g/lbf 3 - 110 Hz, 0.0054 g/lbf
3 - 185.0 Hz, 0.0141 g/lbf 1 4 - 140 Hz, 0.0017 g/lbf
20m 2 500m

400m
15m 3

300m
Amplitude g/lbf

Amplitude g/lbf
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER027 1 - 55 Hz, 0.0042 g/lbf PASS


1 - 99.0 Hz, 0.0567 g/lbf 2 - 70 Hz, 0.0016 g/lbf
2 - 65.0 Hz, 0.0423 g/lbf 3 - 110 Hz, 0.0036 g/lbf
3 - 159.5 Hz, 0.0387 g/lbf 4 - 140 Hz, 0.0037 g/lbf
80m 500m

400m
60m 1

2 300m
Amplitude g/lbf

Amplitude g/lbf

3
40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET027 1 - 55 Hz, 0.0041 g/lbf PASS


1 - 185.5 Hz, 0.2749 g/lbf 2 - 70 Hz, 0.0053 g/lbf
2 - 153.5 Hz, 0.0765 g/lbf 3 - 110 Hz, 0.0227 g/lbf
3 - 157.5 Hz, 0.0763 g/lbf 4 - 140 Hz, 0.0367 g/lbf
400m 500m

400m
300m 1

300m
Amplitude g/lbf

Amplitude g/lbf

200m
200m

100m 23
100m

2 3
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1009 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA028 1 - 55 Hz, 0.0015 g/lbf PASS


1 - 122.0 Hz, 0.0169 g/lbf 2 - 70 Hz, 0.0008 g/lbf
2 - 189.0 Hz, 0.0152 g/lbf 3 - 110 Hz, 0.0044 g/lbf
3 - 184.0 Hz, 0.0131 g/lbf 4 - 140 Hz, 0.0015 g/lbf
20m 500m
1
2 400m
15m
3
300m
Amplitude g/lbf

Amplitude g/lbf
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER028 1 - 55 Hz, 0.0053 g/lbf PASS


1 - 99.0 Hz, 0.0778 g/lbf 2 - 70 Hz, 0.0012 g/lbf
2 - 184.0 Hz, 0.0638 g/lbf 3 - 110 Hz, 0.0077 g/lbf
3 - 131.0 Hz, 0.0526 g/lbf 4 - 140 Hz, 0.0027 g/lbf
1
80m 500m

2
400m
60m
3
300m
Amplitude g/lbf

Amplitude g/lbf

40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET028 1 - 55 Hz, 0.0025 g/lbf PASS


1 - 185.0 Hz, 0.0739 g/lbf 2 - 70 Hz, 0.0018 g/lbf
2 - 153.5 Hz, 0.0349 g/lbf 3 - 110 Hz, 0.0124 g/lbf
3 - 192.0 Hz, 0.0323 g/lbf 4 - 140 Hz, 0.0167 g/lbf
80m 1 500m

400m
60m

300m
Amplitude g/lbf

Amplitude g/lbf

40m 2
3
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1010 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA029 1 - 55 Hz, 0.0017 g/lbf PASS


1 - 189.0 Hz, 0.0231 g/lbf 2 - 70 Hz, 0.0007 g/lbf
2 - 122.0 Hz, 0.0139 g/lbf 3 - 110 Hz, 0.0033 g/lbf
3 - 65.0 Hz, 0.0114 g/lbf 4 - 140 Hz, 0.0016 g/lbf
40m 500m

400m
30m

1 300m
Amplitude g/lbf

Amplitude g/lbf
20m
2 200m
3
10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER029 1 - 55 Hz, 0.0047 g/lbf PASS


1 - 99.0 Hz, 0.0681 g/lbf 2 - 70 Hz, 0.0015 g/lbf
2 - 184.5 Hz, 0.0576 g/lbf 3 - 110 Hz, 0.0066 g/lbf
3 - 65.0 Hz, 0.0515 g/lbf 4 - 140 Hz, 0.0025 g/lbf
80m 500m
1

2 400m
60m
3
300m
Amplitude g/lbf

Amplitude g/lbf

40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET029 1 - 55 Hz, 0.0017 g/lbf PASS


1 - 185.0 Hz, 0.0493 g/lbf 2 - 70 Hz, 0.0018 g/lbf
2 - 177.5 Hz, 0.0330 g/lbf 3 - 110 Hz, 0.0106 g/lbf
3 - 153.0 Hz, 0.0261 g/lbf 1 4 - 140 Hz, 0.0128 g/lbf
50m 500m

40m 400m
2
30m 300m
Amplitude g/lbf

Amplitude g/lbf

20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1011 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA030 1 - 55 Hz, 0.0018 g/lbf PASS


1 - 187.0 Hz, 0.0248 g/lbf 2 - 70 Hz, 0.0012 g/lbf
2 - 121.5 Hz, 0.0187 g/lbf 3 - 110 Hz, 0.0059 g/lbf
3 - 160.0 Hz, 0.0123 g/lbf 4 - 140 Hz, 0.0035 g/lbf
40m 500m

400m
30m
1
300m
Amplitude g/lbf

Amplitude g/lbf
20m 2
200m
3
10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER030 1 - 55 Hz, 0.0049 g/lbf PASS


1 - 99.0 Hz, 0.0620 g/lbf 2 - 70 Hz, 0.0016 g/lbf
2 - 65.0 Hz, 0.0539 g/lbf 3 - 110 Hz, 0.0074 g/lbf
3 - 163.0 Hz, 0.0462 g/lbf 4 - 140 Hz, 0.0029 g/lbf
80m 500m

1 400m
60m 2
3 300m
Amplitude g/lbf

Amplitude g/lbf

40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET030 1 - 55 Hz, 0.0039 g/lbf PASS


1 - 185.0 Hz, 0.1046 g/lbf 2 - 70 Hz, 0.0044 g/lbf
2 - 190.0 Hz, 0.0888 g/lbf 3 - 110 Hz, 0.0205 g/lbf
3 - 191.0 Hz, 0.0881 g/lbf 4 - 140 Hz, 0.0291 g/lbf
200m 500m

400m

300m
Amplitude g/lbf

Amplitude g/lbf

1
100m 23
200m

100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1012 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA031 1 - 55 Hz, 0.0016 g/lbf PASS


1 - 187.0 Hz, 0.0241 g/lbf 2 - 70 Hz, 0.0011 g/lbf
2 - 190.0 Hz, 0.0213 g/lbf 3 - 110 Hz, 0.0048 g/lbf
3 - 121.5 Hz, 0.0187 g/lbf 4 - 140 Hz, 0.0022 g/lbf
40m 500m

400m
30m
1
2 300m
Amplitude g/lbf

Amplitude g/lbf
20m 3
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER031 1 - 55 Hz, 0.0043 g/lbf PASS


1 - 65.0 Hz, 0.0486 g/lbf 2 - 70 Hz, 0.0022 g/lbf
2 - 97.5 Hz, 0.0396 g/lbf 3 - 110 Hz, 0.0061 g/lbf
3 - 99.0 Hz, 0.0363 g/lbf 4 - 140 Hz, 0.0046 g/lbf
80m 500m

400m
60m
1
300m
Amplitude g/lbf

Amplitude g/lbf

2
40m 3
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET031 1 - 55 Hz, 0.0020 g/lbf PASS


1 - 185.5 Hz, 0.0540 g/lbf 2 - 70 Hz, 0.0021 g/lbf
2 - 189.5 Hz, 0.0467 g/lbf 3 - 110 Hz, 0.0120 g/lbf
3 - 153.5 Hz, 0.0297 g/lbf 4 - 140 Hz, 0.0156 g/lbf
80m 500m

400m
60m 1
2 300m
Amplitude g/lbf

Amplitude g/lbf

40m
3 200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1013 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA032 1 - 55 Hz, 0.0015 g/lbf PASS


1 - 121.5 Hz, 0.0215 g/lbf 2 - 70 Hz, 0.0011 g/lbf
2 - 185.0 Hz, 0.0211 g/lbf 3 - 110 Hz, 0.0060 g/lbf
3 - 158.5 Hz, 0.0122 g/lbf 4 - 140 Hz, 0.0023 g/lbf
40m 500m

400m
30m

1 300m
Amplitude g/lbf

Amplitude g/lbf
2
20m
200m
3
10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER032 1 - 55 Hz, 0.0045 g/lbf PASS


1 - 97.5 Hz, 0.0510 g/lbf 2 - 70 Hz, 0.0025 g/lbf
2 - 65.0 Hz, 0.0485 g/lbf 3 - 110 Hz, 0.0061 g/lbf
3 - 133.5 Hz, 0.0437 g/lbf 4 - 140 Hz, 0.0064 g/lbf
80m 500m

400m
60m
2 1
3 300m
Amplitude g/lbf

Amplitude g/lbf

40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET032 1 - 55 Hz, 0.0025 g/lbf PASS


1 - 189.5 Hz, 0.0757 g/lbf 2 - 70 Hz, 0.0026 g/lbf
2 - 153.5 Hz, 0.0388 g/lbf 3 - 110 Hz, 0.0145 g/lbf
3 - 157.0 Hz, 0.0318 g/lbf 4 - 140 Hz, 0.0191 g/lbf
80m 1 500m

400m
60m

300m
Amplitude g/lbf

Amplitude g/lbf

40m 2
3
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1014 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA033 1 - 55 Hz, 0.0013 g/lbf PASS


1 - 186.0 Hz, 0.0222 g/lbf 2 - 70 Hz, 0.0011 g/lbf
2 - 121.5 Hz, 0.0188 g/lbf 3 - 110 Hz, 0.0050 g/lbf
3 - 191.0 Hz, 0.0131 g/lbf 4 - 140 Hz, 0.0026 g/lbf
40m 500m

400m
30m

1 300m
Amplitude g/lbf

Amplitude g/lbf
20m 2

3 200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER033 1 - 55 Hz, 0.0043 g/lbf PASS


1 - 97.5 Hz, 0.0584 g/lbf 2 - 70 Hz, 0.0029 g/lbf
2 - 133.5 Hz, 0.0532 g/lbf 3 - 110 Hz, 0.0052 g/lbf
3 - 65.0 Hz, 0.0440 g/lbf 4 - 140 Hz, 0.0071 g/lbf
80m 500m

1 400m
60m
2
3 300m
Amplitude g/lbf

Amplitude g/lbf

40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET033 1 - 55 Hz, 0.0030 g/lbf PASS


1 - 189.0 Hz, 0.0799 g/lbf 2 - 70 Hz, 0.0035 g/lbf
2 - 154.0 Hz, 0.0418 g/lbf 3 - 110 Hz, 0.0158 g/lbf
3 - 157.0 Hz, 0.0371 g/lbf 4 - 140 Hz, 0.0223 g/lbf
80m 500m

400m
60m

300m
Amplitude g/lbf

Amplitude g/lbf

2
40m 3
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1015 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA034 1 - 55 Hz, 0.0013 g/lbf PASS


1 - 121.5 Hz, 0.0205 g/lbf 2 - 70 Hz, 0.0006 g/lbf
2 - 185.5 Hz, 0.0170 g/lbf 3 - 110 Hz, 0.0040 g/lbf
3 - 97.5 Hz, 0.0087 g/lbf 4 - 140 Hz, 0.0010 g/lbf
40m 500m

400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf
1
20m
2
200m

10m 3
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER034 1 - 55 Hz, 0.0038 g/lbf PASS


1 - 97.5 Hz, 0.0597 g/lbf 2 - 70 Hz, 0.0030 g/lbf
2 - 133.5 Hz, 0.0543 g/lbf 3 - 110 Hz, 0.0046 g/lbf
3 - 65.0 Hz, 0.0390 g/lbf 4 - 140 Hz, 0.0071 g/lbf
80m 500m

1 400m
60m 2

300m
Amplitude g/lbf

Amplitude g/lbf

3
40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET034 1 - 55 Hz, 0.0014 g/lbf PASS


1 - 189.0 Hz, 0.0456 g/lbf 2 - 70 Hz, 0.0007 g/lbf
2 - 154.5 Hz, 0.0234 g/lbf 3 - 110 Hz, 0.0075 g/lbf
3 - 157.5 Hz, 0.0202 g/lbf 4 - 140 Hz, 0.0097 g/lbf
50m 1 500m

40m 400m

30m 300m
Amplitude g/lbf

Amplitude g/lbf

2
3
20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1016 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA035 1 - 55 Hz, 0.0012 g/lbf PASS


1 - 121.5 Hz, 0.0223 g/lbf 2 - 70 Hz, 0.0009 g/lbf
2 - 186.0 Hz, 0.0157 g/lbf 3 - 110 Hz, 0.0066 g/lbf
3 - 153.5 Hz, 0.0078 g/lbf 4 - 140 Hz, 0.0019 g/lbf
40m 500m

400m
30m

1 300m
Amplitude g/lbf

Amplitude g/lbf
20m
2
200m

10m 3
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER035 1 - 55 Hz, 0.0037 g/lbf PASS


1 - 97.5 Hz, 0.0565 g/lbf 2 - 70 Hz, 0.0029 g/lbf
2 - 133.5 Hz, 0.0479 g/lbf 3 - 110 Hz, 0.0046 g/lbf
3 - 65.0 Hz, 0.0361 g/lbf 4 - 140 Hz, 0.0063 g/lbf
80m 500m

400m
60m 1
2
300m
Amplitude g/lbf

Amplitude g/lbf

40m 3
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET035 1 - 55 Hz, 0.0022 g/lbf PASS


1 - 189.0 Hz, 0.0618 g/lbf 2 - 70 Hz, 0.0023 g/lbf
2 - 188.0 Hz, 0.0609 g/lbf 3 - 110 Hz, 0.0124 g/lbf
3 - 185.5 Hz, 0.0589 g/lbf 4 - 140 Hz, 0.0161 g/lbf
80m 500m

1
32 400m
60m

300m
Amplitude g/lbf

Amplitude g/lbf

40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1017 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA036 1 - 55 Hz, 0.0016 g/lbf PASS


1 - 121.5 Hz, 0.0198 g/lbf 2 - 70 Hz, 0.0006 g/lbf
2 - 188.5 Hz, 0.0178 g/lbf 3 - 110 Hz, 0.0046 g/lbf
3 - 65.5 Hz, 0.0107 g/lbf 1 4 - 140 Hz, 0.0021 g/lbf
20m 500m
2

400m
15m

3 300m
Amplitude g/lbf

Amplitude g/lbf
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER036 1 - 55 Hz, 0.0042 g/lbf PASS


1 - 97.5 Hz, 0.0569 g/lbf 2 - 70 Hz, 0.0025 g/lbf
2 - 65.5 Hz, 0.0432 g/lbf 3 - 110 Hz, 0.0059 g/lbf
3 - 131.0 Hz, 0.0409 g/lbf 4 - 140 Hz, 0.0038 g/lbf
80m 500m

400m
60m 1

2 300m
Amplitude g/lbf

Amplitude g/lbf

3
40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET036 1 - 55 Hz, 0.0027 g/lbf PASS


1 - 185.0 Hz, 0.0697 g/lbf 2 - 70 Hz, 0.0028 g/lbf
2 - 155.0 Hz, 0.0463 g/lbf 3 - 110 Hz, 0.0138 g/lbf
3 - 159.0 Hz, 0.0454 g/lbf 4 - 140 Hz, 0.0192 g/lbf
100m 500m

400m
1

300m
Amplitude g/lbf

Amplitude g/lbf

50m 23
200m

100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1018 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA037 1 - 55 Hz, 0.0014 g/lbf PASS


1 - 188.5 Hz, 0.0236 g/lbf 2 - 70 Hz, 0.0010 g/lbf
2 - 121.5 Hz, 0.0208 g/lbf 3 - 110 Hz, 0.0060 g/lbf
3 - 99.0 Hz, 0.0104 g/lbf 4 - 140 Hz, 0.0026 g/lbf
40m 500m

400m
30m
1
300m
Amplitude g/lbf

Amplitude g/lbf
2
20m
200m
3
10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER037 1 - 55 Hz, 0.0040 g/lbf PASS


1 - 131.0 Hz, 0.0539 g/lbf 2 - 70 Hz, 0.0024 g/lbf
2 - 65.5 Hz, 0.0478 g/lbf 3 - 110 Hz, 0.0057 g/lbf
3 - 162.5 Hz, 0.0474 g/lbf 4 - 140 Hz, 0.0027 g/lbf
80m 500m

400m
60m 1
2 3
300m
Amplitude g/lbf

Amplitude g/lbf

40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET037 1 - 55 Hz, 0.0030 g/lbf PASS


1 - 185.5 Hz, 0.0714 g/lbf 2 - 70 Hz, 0.0035 g/lbf
2 - 159.0 Hz, 0.0522 g/lbf 3 - 110 Hz, 0.0157 g/lbf
3 - 155.0 Hz, 0.0498 g/lbf 4 - 140 Hz, 0.0217 g/lbf
100m 500m

400m
1

300m
Amplitude g/lbf

Amplitude g/lbf

32
50m
200m

100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1019 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA038 1 - 55 Hz, 0.0015 g/lbf PASS


1 - 188.5 Hz, 0.0240 g/lbf 2 - 70 Hz, 0.0009 g/lbf
2 - 121.5 Hz, 0.0188 g/lbf 3 - 110 Hz, 0.0052 g/lbf
3 - 99.0 Hz, 0.0128 g/lbf 4 - 140 Hz, 0.0023 g/lbf
80m 500m

400m
60m

300m
Amplitude g/lbf

Amplitude g/lbf
40m
200m
1
20m 2
3 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER038 1 - 55 Hz, 0.0040 g/lbf PASS


1 - 131.0 Hz, 0.0730 g/lbf 2 - 70 Hz, 0.0027 g/lbf
2 - 65.5 Hz, 0.0533 g/lbf 3 - 110 Hz, 0.0057 g/lbf
3 - 163.0 Hz, 0.0515 g/lbf 4 - 140 Hz, 0.0036 g/lbf
80m 1 500m

400m
60m
2 3
300m
Amplitude g/lbf

Amplitude g/lbf

40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET038 1 - 55 Hz, 0.0019 g/lbf PASS


1 - 186.5 Hz, 0.0486 g/lbf 2 - 70 Hz, 0.0022 g/lbf
2 - 159.0 Hz, 0.0337 g/lbf 3 - 110 Hz, 0.0103 g/lbf
3 - 155.0 Hz, 0.0320 g/lbf 4 - 140 Hz, 0.0150 g/lbf
80m 500m

400m
60m
1
300m
Amplitude g/lbf

Amplitude g/lbf

40m
32
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1020 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA039 1 - 55 Hz, 0.0013 g/lbf PASS


1 - 188.5 Hz, 0.0181 g/lbf 2 - 70 Hz, 0.0005 g/lbf
2 - 122.0 Hz, 0.0153 g/lbf 3 - 110 Hz, 0.0034 g/lbf
3 - 99.0 Hz, 0.0134 g/lbf 4 - 140 Hz, 0.0010 g/lbf
20m 500m
1

2 400m
15m
3
300m
Amplitude g/lbf

Amplitude g/lbf
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER039 1 - 55 Hz, 0.0037 g/lbf PASS


1 - 131.0 Hz, 0.0642 g/lbf 2 - 70 Hz, 0.0028 g/lbf
2 - 99.0 Hz, 0.0597 g/lbf 3 - 110 Hz, 0.0058 g/lbf
3 - 65.5 Hz, 0.0517 g/lbf 4 - 140 Hz, 0.0055 g/lbf
80m 500m

1
2 400m
60m
3
300m
Amplitude g/lbf

Amplitude g/lbf

40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET039 1 - 55 Hz, 0.0017 g/lbf PASS


1 - 186.0 Hz, 0.0450 g/lbf 2 - 70 Hz, 0.0017 g/lbf
2 - 163.5 Hz, 0.0267 g/lbf 3 - 110 Hz, 0.0088 g/lbf
3 - 159.0 Hz, 0.0261 g/lbf 4 - 140 Hz, 0.0127 g/lbf
80m 500m

400m
60m

1 300m
Amplitude g/lbf

Amplitude g/lbf

40m

32 200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1021 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA040 1 - 55 Hz, 0.0015 g/lbf PASS


1 - 186.5 Hz, 0.0155 g/lbf 2 - 70 Hz, 0.0005 g/lbf
2 - 122.0 Hz, 0.0150 g/lbf 3 - 110 Hz, 0.0033 g/lbf
3 - 99.0 Hz, 0.0148 g/lbf 4 - 140 Hz, 0.0013 g/lbf
20m 500m

2 1 400m
3
15m

300m
Amplitude g/lbf

Amplitude g/lbf
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER040 1 - 55 Hz, 0.0032 g/lbf PASS


1 - 99.0 Hz, 0.0558 g/lbf 2 - 70 Hz, 0.0026 g/lbf
2 - 131.0 Hz, 0.0505 g/lbf 3 - 110 Hz, 0.0051 g/lbf
3 - 65.5 Hz, 0.0449 g/lbf 4 - 140 Hz, 0.0059 g/lbf
80m 500m

400m
60m 1
2
3 300m
Amplitude g/lbf

Amplitude g/lbf

40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET040 1 - 55 Hz, 0.0018 g/lbf PASS


1 - 186.0 Hz, 0.0509 g/lbf 2 - 70 Hz, 0.0021 g/lbf
2 - 155.5 Hz, 0.0307 g/lbf 3 - 110 Hz, 0.0105 g/lbf
3 - 163.5 Hz, 0.0302 g/lbf 4 - 140 Hz, 0.0142 g/lbf
80m 500m

400m
60m
1
300m
Amplitude g/lbf

Amplitude g/lbf

40m
2 3 200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1022 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA041 1 - 55 Hz, 0.0014 g/lbf PASS


1 - 186.0 Hz, 0.0199 g/lbf 2 - 70 Hz, 0.0006 g/lbf
2 - 122.5 Hz, 0.0148 g/lbf 3 - 110 Hz, 0.0038 g/lbf
3 - 99.0 Hz, 0.0097 g/lbf 4 - 140 Hz, 0.0016 g/lbf
20m 500m

2 400m
15m

300m
Amplitude g/lbf

Amplitude g/lbf
10m 3

200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER041 1 - 55 Hz, 0.0034 g/lbf PASS


1 - 99.0 Hz, 0.0561 g/lbf 2 - 70 Hz, 0.0029 g/lbf
2 - 133.5 Hz, 0.0508 g/lbf 3 - 110 Hz, 0.0049 g/lbf
3 - 65.5 Hz, 0.0431 g/lbf 4 - 140 Hz, 0.0066 g/lbf
80m 500m

400m
60m 1
2
3 300m
Amplitude g/lbf

Amplitude g/lbf

40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET041 1 - 55 Hz, 0.0014 g/lbf PASS


1 - 186.0 Hz, 0.0331 g/lbf 2 - 70 Hz, 0.0014 g/lbf
2 - 189.0 Hz, 0.0260 g/lbf 3 - 110 Hz, 0.0073 g/lbf
3 - 153.5 Hz, 0.0214 g/lbf 4 - 140 Hz, 0.0103 g/lbf
40m 500m
1
400m
30m
2
3 300m
Amplitude g/lbf

Amplitude g/lbf

20m
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1023 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA042 1 - 55 Hz, 0.0015 g/lbf PASS


1 - 186.0 Hz, 0.0211 g/lbf 2 - 70 Hz, 0.0005 g/lbf
2 - 122.5 Hz, 0.0151 g/lbf 3 - 110 Hz, 0.0036 g/lbf
3 - 162.5 Hz, 0.0104 g/lbf 4 - 140 Hz, 0.0012 g/lbf
50m 500m

40m 400m

30m 300m
Amplitude g/lbf

Amplitude g/lbf
1
20m 200m
2
3
10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER042 1 - 55 Hz, 0.0032 g/lbf PASS


1 - 133.5 Hz, 0.0512 g/lbf 2 - 70 Hz, 0.0028 g/lbf
2 - 99.0 Hz, 0.0474 g/lbf 3 - 110 Hz, 0.0046 g/lbf
3 - 159.5 Hz, 0.0366 g/lbf 4 - 140 Hz, 0.0063 g/lbf
80m 500m

400m
60m
1
2
300m
Amplitude g/lbf

Amplitude g/lbf

40m 3
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET042 1 - 55 Hz, 0.0015 g/lbf PASS


1 - 185.5 Hz, 0.0306 g/lbf 2 - 70 Hz, 0.0014 g/lbf
2 - 189.0 Hz, 0.0268 g/lbf 3 - 110 Hz, 0.0077 g/lbf
3 - 153.5 Hz, 0.0212 g/lbf 4 - 140 Hz, 0.0100 g/lbf
40m 500m

1 400m
30m
2

3 300m
Amplitude g/lbf

Amplitude g/lbf

20m
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1024 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA043 1 - 55 Hz, 0.0014 g/lbf PASS


1 - 186.0 Hz, 0.0214 g/lbf 2 - 70 Hz, 0.0008 g/lbf
2 - 122.5 Hz, 0.0163 g/lbf 3 - 110 Hz, 0.0051 g/lbf
3 - 162.5 Hz, 0.0105 g/lbf 4 - 140 Hz, 0.0023 g/lbf
40m 500m

400m
30m

1 300m
Amplitude g/lbf

Amplitude g/lbf
20m
2
200m
3
10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER043 1 - 55 Hz, 0.0031 g/lbf PASS


1 - 133.5 Hz, 0.0452 g/lbf 2 - 70 Hz, 0.0026 g/lbf
2 - 99.0 Hz, 0.0357 g/lbf 3 - 110 Hz, 0.0041 g/lbf
3 - 65.0 Hz, 0.0328 g/lbf 4 - 140 Hz, 0.0050 g/lbf
50m 1 500m

40m 400m
2
3
30m 300m
Amplitude g/lbf

Amplitude g/lbf

20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET043 1 - 55 Hz, 0.0024 g/lbf PASS


1 - 189.0 Hz, 0.0484 g/lbf 2 - 70 Hz, 0.0022 g/lbf
2 - 188.0 Hz, 0.0475 g/lbf 3 - 110 Hz, 0.0113 g/lbf
3 - 185.5 Hz, 0.0464 g/lbf 4 - 140 Hz, 0.0149 g/lbf
80m 500m

400m
60m
321 300m
Amplitude g/lbf

Amplitude g/lbf

40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1025 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA044 1 - 55 Hz, 0.0008 g/lbf PASS


1 - 122.0 Hz, 0.0153 g/lbf 2 - 70 Hz, 0.0012 g/lbf
2 - 125.0 Hz, 0.0127 g/lbf 3 - 110 Hz, 0.0093 g/lbf
3 - 155.5 Hz, 0.0106 g/lbf 4 - 140 Hz, 0.0032 g/lbf
20m 500m

1 400m
15m
2
3 300m
Amplitude g/lbf

Amplitude g/lbf
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER044 1 - 55 Hz, 0.0033 g/lbf PASS


1 - 97.5 Hz, 0.0394 g/lbf 2 - 70 Hz, 0.0023 g/lbf
2 - 65.0 Hz, 0.0380 g/lbf 3 - 110 Hz, 0.0040 g/lbf
3 - 163.0 Hz, 0.0375 g/lbf1 4 - 140 Hz, 0.0024 g/lbf
40m 2 3 500m

400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf

20m
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET044 1 - 55 Hz, 0.0015 g/lbf PASS


1 - 188.5 Hz, 0.0343 g/lbf 2 - 70 Hz, 0.0010 g/lbf
2 - 154.0 Hz, 0.0222 g/lbf 3 - 110 Hz, 0.0074 g/lbf
3 - 176.0 Hz, 0.0193 g/lbf 4 - 140 Hz, 0.0102 g/lbf
40m 500m
1
400m
30m

2 300m
Amplitude g/lbf

Amplitude g/lbf

20m 3

200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1026 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA045 1 - 55 Hz, 0.0011 g/lbf PASS


1 - 122.0 Hz, 0.0159 g/lbf 2 - 70 Hz, 0.0013 g/lbf
2 - 125.0 Hz, 0.0150 g/lbf 3 - 110 Hz, 0.0095 g/lbf
3 - 153.5 Hz, 0.0123 g/lbf 4 - 140 Hz, 0.0038 g/lbf
20m 500m

1
2 400m
15m
3
300m
Amplitude g/lbf

Amplitude g/lbf
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER045 1 - 55 Hz, 0.0033 g/lbf PASS


1 - 97.5 Hz, 0.0441 g/lbf 2 - 70 Hz, 0.0020 g/lbf
2 - 65.0 Hz, 0.0399 g/lbf 3 - 110 Hz, 0.0044 g/lbf
3 - 163.0 Hz, 0.0378 g/lbf 4 - 140 Hz, 0.0025 g/lbf
50m 500m
1
2
40m 3 400m

30m 300m
Amplitude g/lbf

Amplitude g/lbf

20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET045 1 - 55 Hz, 0.0024 g/lbf PASS


1 - 188.0 Hz, 0.0518 g/lbf 2 - 70 Hz, 0.0018 g/lbf
2 - 153.5 Hz, 0.0319 g/lbf 3 - 110 Hz, 0.0117 g/lbf
3 - 163.0 Hz, 0.0259 g/lbf 4 - 140 Hz, 0.0161 g/lbf
80m 500m

400m
60m
1
300m
Amplitude g/lbf

Amplitude g/lbf

40m
2
200m
3
20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1027 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA046 1 - 55 Hz, 0.0009 g/lbf PASS


1 - 122.5 Hz, 0.0148 g/lbf 2 - 70 Hz, 0.0011 g/lbf
2 - 125.0 Hz, 0.0141 g/lbf 3 - 110 Hz, 0.0083 g/lbf
3 - 185.5 Hz, 0.0115 g/lbf 4 - 140 Hz, 0.0027 g/lbf
20m 500m

12 400m
15m

3 300m
Amplitude g/lbf

Amplitude g/lbf
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER046 1 - 55 Hz, 0.0030 g/lbf PASS


1 - 97.5 Hz, 0.0437 g/lbf 2 - 70 Hz, 0.0020 g/lbf
2 - 65.0 Hz, 0.0424 g/lbf 3 - 110 Hz, 0.0036 g/lbf
3 - 131.5 Hz, 0.0333 g/lbf 4 - 140 Hz, 0.0028 g/lbf
200m 500m

400m

300m
Amplitude g/lbf

Amplitude g/lbf

100m
200m

2 1
3 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET046 1 - 55 Hz, 0.0012 g/lbf PASS


1 - 185.5 Hz, 0.0196 g/lbf 2 - 70 Hz, 0.0008 g/lbf
2 - 163.0 Hz, 0.0150 g/lbf 3 - 110 Hz, 0.0047 g/lbf
3 - 153.5 Hz, 0.0142 g/lbf 4 - 140 Hz, 0.0079 g/lbf
40m 500m

400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf

1
20m
3 2 200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1028 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA047 1 - 55 Hz, 0.0009 g/lbf PASS


1 - 125.0 Hz, 0.0163 g/lbf 2 - 70 Hz, 0.0010 g/lbf
2 - 122.5 Hz, 0.0154 g/lbf 3 - 110 Hz, 0.0084 g/lbf
3 - 185.5 Hz, 0.0109 g/lbf 4 - 140 Hz, 0.0027 g/lbf
20m 500m

1
2 400m
15m

3 300m
Amplitude g/lbf

Amplitude g/lbf
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER047 1 - 55 Hz, 0.0029 g/lbf PASS


1 - 65.0 Hz, 0.0448 g/lbf 2 - 70 Hz, 0.0021 g/lbf
2 - 97.5 Hz, 0.0428 g/lbf 3 - 110 Hz, 0.0028 g/lbf
3 - 131.5 Hz, 0.0368 g/lbf 4 - 140 Hz, 0.0036 g/lbf
50m 500m
1
2
40m 3 400m

30m 300m
Amplitude g/lbf

Amplitude g/lbf

20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET047 1 - 55 Hz, 0.0012 g/lbf PASS


1 - 185.0 Hz, 0.0215 g/lbf 2 - 70 Hz, 0.0004 g/lbf
2 - 163.5 Hz, 0.0173 g/lbf 3 - 110 Hz, 0.0048 g/lbf
3 - 153.5 Hz, 0.0151 g/lbf 4 - 140 Hz, 0.0075 g/lbf
40m 500m

400m
30m

1 300m
Amplitude g/lbf

Amplitude g/lbf

20m 2
3 200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1029 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA048 1 - 55 Hz, 0.0009 g/lbf PASS


1 - 124.5 Hz, 0.0184 g/lbf 2 - 70 Hz, 0.0010 g/lbf
2 - 123.0 Hz, 0.0170 g/lbf 3 - 110 Hz, 0.0086 g/lbf
3 - 126.0 Hz, 0.0147 g/lbf 4 - 140 Hz, 0.0030 g/lbf
20m 1 500m
2
3 400m
15m

300m
Amplitude g/lbf

Amplitude g/lbf
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER048 1 - 55 Hz, 0.0027 g/lbf PASS


1 - 65.0 Hz, 0.0437 g/lbf 2 - 70 Hz, 0.0020 g/lbf
2 - 97.5 Hz, 0.0386 g/lbf 3 - 110 Hz, 0.0024 g/lbf
3 - 159.5 Hz, 0.0385 g/lbf 4 - 140 Hz, 0.0038 g/lbf
50m 500m
1

40m 2 3 400m

30m 300m
Amplitude g/lbf

Amplitude g/lbf

20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET048 1 - 55 Hz, 0.0013 g/lbf PASS


1 - 184.5 Hz, 0.0239 g/lbf 2 - 70 Hz, 0.0007 g/lbf
2 - 163.0 Hz, 0.0179 g/lbf 3 - 110 Hz, 0.0056 g/lbf
3 - 154.0 Hz, 0.0171 g/lbf 4 - 140 Hz, 0.0081 g/lbf
40m 500m

400m
30m
1
300m
Amplitude g/lbf

Amplitude g/lbf

20m 3 2
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1030 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA049 1 - 55 Hz, 0.0011 g/lbf PASS


1 - 124.5 Hz, 0.0225 g/lbf 2 - 70 Hz, 0.0013 g/lbf
2 - 184.5 Hz, 0.0147 g/lbf 3 - 110 Hz, 0.0100 g/lbf
3 - 153.5 Hz, 0.0134 g/lbf 4 - 140 Hz, 0.0041 g/lbf
40m 500m

400m
30m

1 300m
Amplitude g/lbf

Amplitude g/lbf
20m
2 200m
3

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER049 1 - 55 Hz, 0.0027 g/lbf PASS


1 - 65.0 Hz, 0.0425 g/lbf 2 - 70 Hz, 0.0018 g/lbf
2 - 159.5 Hz, 0.0362 g/lbf 3 - 110 Hz, 0.0017 g/lbf
3 - 97.5 Hz, 0.0332 g/lbf 4 - 140 Hz, 0.0034 g/lbf
50m 500m
1
40m 2 400m
3
30m 300m
Amplitude g/lbf

Amplitude g/lbf

20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET049 1 - 55 Hz, 0.0014 g/lbf PASS


1 - 185.0 Hz, 0.0271 g/lbf 2 - 70 Hz, 0.0008 g/lbf
2 - 190.0 Hz, 0.0194 g/lbf 3 - 110 Hz, 0.0065 g/lbf
3 - 159.5 Hz, 0.0194 g/lbf 4 - 140 Hz, 0.0101 g/lbf
40m 500m

400m
30m 1
300m
Amplitude g/lbf

Amplitude g/lbf

20m 3 2

200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1031 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA050 1 - 55 Hz, 0.0010 g/lbf PASS


1 - 124.5 Hz, 0.0216 g/lbf 2 - 70 Hz, 0.0012 g/lbf
2 - 189.0 Hz, 0.0161 g/lbf 3 - 110 Hz, 0.0096 g/lbf
3 - 184.5 Hz, 0.0123 g/lbf 4 - 140 Hz, 0.0046 g/lbf
40m 500m

400m
30m

1 300m
Amplitude g/lbf

Amplitude g/lbf
20m
2
200m
3
10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER050 1 - 55 Hz, 0.0031 g/lbf PASS


1 - 65.0 Hz, 0.0414 g/lbf 2 - 70 Hz, 0.0016 g/lbf
2 - 99.0 Hz, 0.0409 g/lbf 3 - 110 Hz, 0.0020 g/lbf
3 - 133.5 Hz, 0.0324 g/lbf 4 - 140 Hz, 0.0035 g/lbf
50m 500m
1 2
40m 400m
3
30m 300m
Amplitude g/lbf

Amplitude g/lbf

20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET050 1 - 55 Hz, 0.0020 g/lbf PASS


1 - 190.5 Hz, 0.0342 g/lbf 2 - 70 Hz, 0.0013 g/lbf
2 - 185.0 Hz, 0.0336 g/lbf 3 - 110 Hz, 0.0082 g/lbf
3 - 154.5 Hz, 0.0263 g/lbf 4 - 140 Hz, 0.0135 g/lbf
50m 500m

40m 400m
21
30m 300m
Amplitude g/lbf

Amplitude g/lbf

20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1032 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA051 1 - 55 Hz, 0.0010 g/lbf PASS


1 - 124.5 Hz, 0.0227 g/lbf 2 - 70 Hz, 0.0011 g/lbf
2 - 189.0 Hz, 0.0150 g/lbf 3 - 110 Hz, 0.0095 g/lbf
3 - 153.5 Hz, 0.0116 g/lbf 4 - 140 Hz, 0.0039 g/lbf
40m 500m

400m
30m

1 300m
Amplitude g/lbf

Amplitude g/lbf
20m
2 200m
3
10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER051 1 - 55 Hz, 0.0029 g/lbf PASS


1 - 99.0 Hz, 0.0478 g/lbf 2 - 70 Hz, 0.0018 g/lbf
2 - 65.0 Hz, 0.0380 g/lbf 3 - 110 Hz, 0.0016 g/lbf
3 - 133.5 Hz, 0.0375 g/lbf 4 - 140 Hz, 0.0036 g/lbf
50m 1 500m

40m 2 3 400m

30m 300m
Amplitude g/lbf

Amplitude g/lbf

20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET051 1 - 55 Hz, 0.0021 g/lbf PASS


1 - 184.5 Hz, 0.0342 g/lbf 2 - 70 Hz, 0.0008 g/lbf
2 - 191.0 Hz, 0.0303 g/lbf 3 - 110 Hz, 0.0054 g/lbf
3 - 154.0 Hz, 0.0233 g/lbf 4 - 140 Hz, 0.0107 g/lbf
50m 500m

40m 400m
1
2
30m 300m
Amplitude g/lbf

Amplitude g/lbf

3
20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1033 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA052 1 - 55 Hz, 0.0011 g/lbf PASS


1 - 124.0 Hz, 0.0204 g/lbf 2 - 70 Hz, 0.0010 g/lbf
2 - 189.0 Hz, 0.0152 g/lbf 3 - 110 Hz, 0.0087 g/lbf
3 - 131.5 Hz, 0.0109 g/lbf 4 - 140 Hz, 0.0037 g/lbf
40m 500m

400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf
1
20m
2 200m
3
10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER052 1 - 55 Hz, 0.0028 g/lbf PASS


1 - 99.0 Hz, 0.0524 g/lbf 2 - 70 Hz, 0.0019 g/lbf
2 - 133.5 Hz, 0.0365 g/lbf 3 - 110 Hz, 0.0012 g/lbf
3 - 65.0 Hz, 0.0326 g/lbf 4 - 140 Hz, 0.0031 g/lbf
80m 500m

400m
60m
1
300m
Amplitude g/lbf

Amplitude g/lbf

40m 2
3
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET052 1 - 55 Hz, 0.0028 g/lbf PASS


1 - 184.5 Hz, 0.0527 g/lbf 2 - 70 Hz, 0.0022 g/lbf
2 - 154.5 Hz, 0.0328 g/lbf 3 - 110 Hz, 0.0084 g/lbf
3 - 157.0 Hz, 0.0294 g/lbf 4 - 140 Hz, 0.0165 g/lbf
80m 500m

400m
60m
1
300m
Amplitude g/lbf

Amplitude g/lbf

40m
2
3 200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1034 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA053 1 - 55 Hz, 0.0011 g/lbf PASS


1 - 124.5 Hz, 0.0205 g/lbf 2 - 70 Hz, 0.0012 g/lbf
2 - 123.0 Hz, 0.0186 g/lbf 3 - 110 Hz, 0.0089 g/lbf
3 - 189.0 Hz, 0.0138 g/lbf 4 - 140 Hz, 0.0042 g/lbf
40m 500m

400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf
1
20m 2
3 200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER053 1 - 55 Hz, 0.0028 g/lbf PASS


1 - 99.0 Hz, 0.0524 g/lbf 2 - 70 Hz, 0.0023 g/lbf
2 - 65.5 Hz, 0.0337 g/lbf 3 - 110 Hz, 0.0012 g/lbf
3 - 133.5 Hz, 0.0318 g/lbf 4 - 140 Hz, 0.0032 g/lbf
80m 500m

400m
60m
1
300m
Amplitude g/lbf

Amplitude g/lbf

40m 2 3
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET053 1 - 55 Hz, 0.0032 g/lbf PASS


1 - 184.0 Hz, 0.0676 g/lbf 2 - 70 Hz, 0.0032 g/lbf
2 - 154.5 Hz, 0.0421 g/lbf 3 - 110 Hz, 0.0110 g/lbf
3 - 188.5 Hz, 0.0418 g/lbf 4 - 140 Hz, 0.0212 g/lbf
80m 500m
1
400m
60m

300m
Amplitude g/lbf

Amplitude g/lbf

2 3
40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1035 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA054 1 - 55 Hz, 0.0013 g/lbf PASS


1 - 188.5 Hz, 0.0143 g/lbf 2 - 70 Hz, 0.0009 g/lbf
2 - 131.5 Hz, 0.0132 g/lbf 3 - 110 Hz, 0.0029 g/lbf
3 - 65.5 Hz, 0.0103 g/lbf 4 - 140 Hz, 0.0013 g/lbf
20m 500m

400m
15m 1
2
300m
Amplitude g/lbf

Amplitude g/lbf
3
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER054 1 - 55 Hz, 0.0031 g/lbf PASS


1 - 99.0 Hz, 0.0485 g/lbf 2 - 70 Hz, 0.0025 g/lbf
2 - 65.5 Hz, 0.0417 g/lbf 3 - 110 Hz, 0.0013 g/lbf
3 - 131.0 Hz, 0.0288 g/lbf 4 - 140 Hz, 0.0034 g/lbf
1
50m 500m
2
40m 400m

30m 3 300m
Amplitude g/lbf

Amplitude g/lbf

20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET054 1 - 55 Hz, 0.0014 g/lbf PASS


1 - 185.0 Hz, 0.0297 g/lbf 2 - 70 Hz, 0.0006 g/lbf
2 - 155.0 Hz, 0.0221 g/lbf 3 - 110 Hz, 0.0064 g/lbf
3 - 159.0 Hz, 0.0194 g/lbf 4 - 140 Hz, 0.0091 g/lbf
40m 500m

1 400m
30m

2 300m
Amplitude g/lbf

Amplitude g/lbf

20m 3

200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1036 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA055 1 - 55 Hz, 0.0014 g/lbf PASS


1 - 131.5 Hz, 0.0149 g/lbf 2 - 70 Hz, 0.0008 g/lbf
2 - 185.5 Hz, 0.0130 g/lbf 3 - 110 Hz, 0.0048 g/lbf
3 - 188.0 Hz, 0.0123 g/lbf 4 - 140 Hz, 0.0017 g/lbf
20m 500m

1 400m
15m
2
3
300m
Amplitude g/lbf

Amplitude g/lbf
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER055 1 - 55 Hz, 0.0031 g/lbf PASS


1 - 65.5 Hz, 0.0482 g/lbf 2 - 70 Hz, 0.0029 g/lbf
2 - 99.0 Hz, 0.0421 g/lbf 3 - 110 Hz, 0.0013 g/lbf
3 - 131.0 Hz, 0.0361 g/lbf 4 - 140 Hz, 0.0039 g/lbf
200m 500m

400m

300m
Amplitude g/lbf

Amplitude g/lbf

100m
200m
1 2 3
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET055 1 - 55 Hz, 0.0017 g/lbf PASS


1 - 184.0 Hz, 0.0333 g/lbf 2 - 70 Hz, 0.0007 g/lbf
2 - 155.0 Hz, 0.0283 g/lbf 3 - 110 Hz, 0.0045 g/lbf
3 - 159.0 Hz, 0.0256 g/lbf 4 - 140 Hz, 0.0102 g/lbf
50m 500m

40m 400m
1
30m 2 300m
Amplitude g/lbf

Amplitude g/lbf

20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1037 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA056 1 - 55 Hz, 0.0010 g/lbf PASS


1 - 124.0 Hz, 0.0198 g/lbf 2 - 70 Hz, 0.0013 g/lbf
2 - 185.5 Hz, 0.0189 g/lbf 3 - 110 Hz, 0.0100 g/lbf
3 - 125.0 Hz, 0.0173 g/lbf 1 4 - 140 Hz, 0.0048 g/lbf
20m 2 500m
3
400m
15m

300m
Amplitude g/lbf

Amplitude g/lbf
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER056 1 - 55 Hz, 0.0031 g/lbf PASS


1 - 65.5 Hz, 0.0514 g/lbf 2 - 70 Hz, 0.0030 g/lbf
2 - 131.5 Hz, 0.0408 g/lbf 3 - 110 Hz, 0.0012 g/lbf
3 - 97.5 Hz, 0.0406 g/lbf 4 - 140 Hz, 0.0038 g/lbf
100m 500m

400m

300m
Amplitude g/lbf

Amplitude g/lbf

1
50m
3 2
200m

100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET056 1 - 55 Hz, 0.0021 g/lbf PASS


1 - 188.5 Hz, 0.0397 g/lbf 2 - 70 Hz, 0.0012 g/lbf
2 - 155.0 Hz, 0.0333 g/lbf 3 - 110 Hz, 0.0058 g/lbf
3 - 159.0 Hz, 0.0328 g/lbf 4 - 140 Hz, 0.0128 g/lbf
80m 500m

400m
60m

300m
Amplitude g/lbf

Amplitude g/lbf

1
40m
23
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1038 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA057 1 - 55 Hz, 0.0013 g/lbf PASS


1 - 155.0 Hz, 0.0213 g/lbf 2 - 70 Hz, 0.0015 g/lbf
2 - 185.0 Hz, 0.0206 g/lbf 3 - 110 Hz, 0.0108 g/lbf
3 - 122.0 Hz, 0.0200 g/lbf 4 - 140 Hz, 0.0055 g/lbf
40m 500m

400m
30m

1 300m
Amplitude g/lbf

Amplitude g/lbf
3 2
20m
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER057 1 - 55 Hz, 0.0031 g/lbf PASS


1 - 65.5 Hz, 0.0510 g/lbf 2 - 70 Hz, 0.0031 g/lbf
2 - 97.5 Hz, 0.0466 g/lbf 3 - 110 Hz, 0.0012 g/lbf
3 - 131.5 Hz, 0.0392 g/lbf 4 - 140 Hz, 0.0038 g/lbf
80m 500m

400m
60m
1
2
300m
Amplitude g/lbf

Amplitude g/lbf

3
40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET057 1 - 55 Hz, 0.0024 g/lbf PASS


1 - 188.5 Hz, 0.0510 g/lbf 2 - 70 Hz, 0.0021 g/lbf
2 - 159.0 Hz, 0.0361 g/lbf 3 - 110 Hz, 0.0079 g/lbf
3 - 155.0 Hz, 0.0342 g/lbf 4 - 140 Hz, 0.0166 g/lbf
80m 500m

400m
60m
1
300m
Amplitude g/lbf

Amplitude g/lbf

40m 32
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1039 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA058 1 - 55 Hz, 0.0010 g/lbf PASS


1 - 122.0 Hz, 0.0157 g/lbf 2 - 70 Hz, 0.0009 g/lbf
2 - 186.0 Hz, 0.0123 g/lbf 3 - 110 Hz, 0.0083 g/lbf
3 - 124.0 Hz, 0.0120 g/lbf 4 - 140 Hz, 0.0032 g/lbf
20m 500m

1 400m
15m
3 2
300m
Amplitude g/lbf

Amplitude g/lbf
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER058 1 - 55 Hz, 0.0036 g/lbf PASS


1 - 97.5 Hz, 0.0564 g/lbf 2 - 70 Hz, 0.0031 g/lbf
2 - 65.5 Hz, 0.0533 g/lbf 3 - 110 Hz, 0.0016 g/lbf
3 - 163.0 Hz, 0.0439 g/lbf 4 - 140 Hz, 0.0036 g/lbf
80m 500m

400m
60m 1
2
3 300m
Amplitude g/lbf

Amplitude g/lbf

40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET058 1 - 55 Hz, 0.0018 g/lbf PASS


1 - 184.5 Hz, 0.0469 g/lbf 2 - 70 Hz, 0.0014 g/lbf
2 - 189.0 Hz, 0.0351 g/lbf 3 - 110 Hz, 0.0069 g/lbf
3 - 158.5 Hz, 0.0329 g/lbf 4 - 140 Hz, 0.0144 g/lbf
80m 500m

400m
60m
1
300m
Amplitude g/lbf

Amplitude g/lbf

40m 2
3
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1040 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA059 1 - 55 Hz, 0.0009 g/lbf PASS


1 - 122.0 Hz, 0.0178 g/lbf 2 - 70 Hz, 0.0009 g/lbf
2 - 155.5 Hz, 0.0148 g/lbf 3 - 110 Hz, 0.0087 g/lbf
3 - 186.5 Hz, 0.0133 g/lbf 4 - 140 Hz, 0.0034 g/lbf
20m 500m
1

2 400m
15m
3
300m
Amplitude g/lbf

Amplitude g/lbf
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER059 1 - 55 Hz, 0.0038 g/lbf PASS


1 - 97.5 Hz, 0.0597 g/lbf 2 - 70 Hz, 0.0030 g/lbf
2 - 163.0 Hz, 0.0586 g/lbf 3 - 110 Hz, 0.0021 g/lbf
3 - 65.5 Hz, 0.0518 g/lbf 4 - 140 Hz, 0.0038 g/lbf
80m 500m

1 2 400m
60m
3
300m
Amplitude g/lbf

Amplitude g/lbf

40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET059 1 - 55 Hz, 0.0020 g/lbf PASS


1 - 184.5 Hz, 0.0453 g/lbf 2 - 70 Hz, 0.0009 g/lbf
2 - 159.0 Hz, 0.0330 g/lbf 3 - 110 Hz, 0.0059 g/lbf
3 - 189.0 Hz, 0.0266 g/lbf 4 - 140 Hz, 0.0121 g/lbf
50m 1
500m

40m 400m
2
30m 3 300m
Amplitude g/lbf

Amplitude g/lbf

20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1041 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA060 1 - 55 Hz, 0.0010 g/lbf PASS


1 - 122.0 Hz, 0.0202 g/lbf 2 - 70 Hz, 0.0010 g/lbf
2 - 155.5 Hz, 0.0162 g/lbf 3 - 110 Hz, 0.0091 g/lbf
3 - 188.5 Hz, 0.0147 g/lbf 4 - 140 Hz, 0.0034 g/lbf
40m 500m

400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf
1
20m
2
3 200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER060 1 - 55 Hz, 0.0040 g/lbf PASS


1 - 163.0 Hz, 0.0569 g/lbf 2 - 70 Hz, 0.0026 g/lbf
2 - 97.5 Hz, 0.0531 g/lbf 3 - 110 Hz, 0.0029 g/lbf
3 - 65.5 Hz, 0.0444 g/lbf 4 - 140 Hz, 0.0028 g/lbf
80m 500m

400m
60m 1
2
3 300m
Amplitude g/lbf

Amplitude g/lbf

40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET060 1 - 55 Hz, 0.0019 g/lbf PASS


1 - 184.0 Hz, 0.0468 g/lbf 2 - 70 Hz, 0.0011 g/lbf
2 - 158.5 Hz, 0.0287 g/lbf 3 - 110 Hz, 0.0060 g/lbf
3 - 153.5 Hz, 0.0244 g/lbf 4 - 140 Hz, 0.0123 g/lbf
50m 1 500m

40m 400m

30m 2 300m
Amplitude g/lbf

Amplitude g/lbf

20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1042 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA061 1 - 55 Hz, 0.0010 g/lbf PASS


1 - 122.0 Hz, 0.0225 g/lbf 2 - 70 Hz, 0.0012 g/lbf
2 - 189.0 Hz, 0.0189 g/lbf 3 - 110 Hz, 0.0096 g/lbf
3 - 155.5 Hz, 0.0153 g/lbf 4 - 140 Hz, 0.0035 g/lbf
40m 500m

400m
30m

1 300m
Amplitude g/lbf

Amplitude g/lbf
20m 2
3 200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER061 1 - 55 Hz, 0.0041 g/lbf PASS


1 - 133.5 Hz, 0.0445 g/lbf 2 - 70 Hz, 0.0028 g/lbf
2 - 97.5 Hz, 0.0415 g/lbf 3 - 110 Hz, 0.0027 g/lbf
3 - 65.5 Hz, 0.0372 g/lbf 4 - 140 Hz, 0.0040 g/lbf
50m 500m
1
2
40m 3 400m

30m 300m
Amplitude g/lbf

Amplitude g/lbf

20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET061 1 - 55 Hz, 0.0021 g/lbf PASS


1 - 185.0 Hz, 0.0558 g/lbf 2 - 70 Hz, 0.0022 g/lbf
2 - 153.0 Hz, 0.0342 g/lbf 3 - 110 Hz, 0.0092 g/lbf
3 - 157.0 Hz, 0.0275 g/lbf 4 - 140 Hz, 0.0188 g/lbf
80m 500m

400m
60m 1

300m
Amplitude g/lbf

Amplitude g/lbf

40m 2
3 200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1043 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA062 1 - 55 Hz, 0.0009 g/lbf PASS


1 - 122.5 Hz, 0.0251 g/lbf 2 - 70 Hz, 0.0011 g/lbf
2 - 189.0 Hz, 0.0205 g/lbf 3 - 110 Hz, 0.0096 g/lbf
3 - 155.5 Hz, 0.0140 g/lbf 4 - 140 Hz, 0.0030 g/lbf
40m 500m

400m
30m
1
300m
Amplitude g/lbf

Amplitude g/lbf
2
20m
3 200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER062 1 - 55 Hz, 0.0040 g/lbf PASS


1 - 99.0 Hz, 0.0510 g/lbf 2 - 70 Hz, 0.0028 g/lbf
2 - 133.5 Hz, 0.0388 g/lbf 3 - 110 Hz, 0.0023 g/lbf
3 - 65.0 Hz, 0.0359 g/lbf 4 - 140 Hz, 0.0047 g/lbf
80m 500m

400m
60m
1
300m
Amplitude g/lbf

Amplitude g/lbf

2
40m 3
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET062 1 - 55 Hz, 0.0021 g/lbf PASS


1 - 185.0 Hz, 0.0519 g/lbf 2 - 70 Hz, 0.0020 g/lbf
2 - 191.5 Hz, 0.0452 g/lbf 3 - 110 Hz, 0.0083 g/lbf
3 - 153.0 Hz, 0.0358 g/lbf 4 - 140 Hz, 0.0172 g/lbf
80m 500m

400m
60m
1
2 300m
Amplitude g/lbf

Amplitude g/lbf

40m 3
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1044 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA063 1 - 55 Hz, 0.0012 g/lbf PASS


1 - 122.5 Hz, 0.0254 g/lbf 2 - 70 Hz, 0.0011 g/lbf
2 - 188.0 Hz, 0.0189 g/lbf 3 - 110 Hz, 0.0091 g/lbf
3 - 155.5 Hz, 0.0116 g/lbf 4 - 140 Hz, 0.0029 g/lbf
40m 500m

400m
30m
1
300m
Amplitude g/lbf

Amplitude g/lbf
20m 2
200m
3
10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER063 1 - 55 Hz, 0.0040 g/lbf PASS


1 - 99.0 Hz, 0.0612 g/lbf 2 - 70 Hz, 0.0027 g/lbf
2 - 65.0 Hz, 0.0374 g/lbf 3 - 110 Hz, 0.0023 g/lbf
3 - 131.0 Hz, 0.0351 g/lbf 4 - 140 Hz, 0.0052 g/lbf
80m 500m

1 400m
60m

300m
Amplitude g/lbf

Amplitude g/lbf

40m 2 3
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET063 1 - 55 Hz, 0.0022 g/lbf PASS


1 - 185.0 Hz, 0.0507 g/lbf 2 - 70 Hz, 0.0018 g/lbf
2 - 189.0 Hz, 0.0478 g/lbf 3 - 110 Hz, 0.0086 g/lbf
3 - 153.5 Hz, 0.0373 g/lbf 4 - 140 Hz, 0.0163 g/lbf
200m 500m

400m

300m
Amplitude g/lbf

Amplitude g/lbf

100m
200m
12
3
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1045 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA064 1 - 55 Hz, 0.0011 g/lbf PASS


1 - 122.5 Hz, 0.0285 g/lbf 2 - 70 Hz, 0.0012 g/lbf
2 - 186.5 Hz, 0.0170 g/lbf 3 - 110 Hz, 0.0102 g/lbf
3 - 188.5 Hz, 0.0165 g/lbf 4 - 140 Hz, 0.0028 g/lbf
40m 500m

400m
30m 1

300m
Amplitude g/lbf

Amplitude g/lbf
20m
23
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER064 1 - 55 Hz, 0.0042 g/lbf PASS


1 - 99.0 Hz, 0.0706 g/lbf 2 - 70 Hz, 0.0028 g/lbf
2 - 131.5 Hz, 0.0458 g/lbf 3 - 110 Hz, 0.0018 g/lbf
3 - 65.0 Hz, 0.0417 g/lbf 4 - 140 Hz, 0.0059 g/lbf
80m 500m
1

400m
60m

2 300m
Amplitude g/lbf

Amplitude g/lbf

3
40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET064 1 - 55 Hz, 0.0020 g/lbf PASS


1 - 184.0 Hz, 0.0440 g/lbf 2 - 70 Hz, 0.0012 g/lbf
2 - 188.5 Hz, 0.0387 g/lbf 3 - 110 Hz, 0.0071 g/lbf
3 - 153.5 Hz, 0.0353 g/lbf 4 - 140 Hz, 0.0138 g/lbf
80m 500m

400m
60m

1 300m
Amplitude g/lbf

Amplitude g/lbf

40m 2
3
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1046 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA065 1 - 55 Hz, 0.0013 g/lbf PASS


1 - 122.5 Hz, 0.0301 g/lbf 2 - 70 Hz, 0.0014 g/lbf
2 - 153.5 Hz, 0.0197 g/lbf 3 - 110 Hz, 0.0111 g/lbf
3 - 186.0 Hz, 0.0180 g/lbf 4 - 140 Hz, 0.0035 g/lbf
40m 500m

1 400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf
2
20m 3
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER065 1 - 55 Hz, 0.0045 g/lbf PASS


1 - 99.0 Hz, 0.0747 g/lbf 2 - 70 Hz, 0.0025 g/lbf
2 - 131.5 Hz, 0.0571 g/lbf 3 - 110 Hz, 0.0021 g/lbf
3 - 65.0 Hz, 0.0448 g/lbf 4 - 140 Hz, 0.0056 g/lbf
80m 1 500m

400m
60m 2

3 300m
Amplitude g/lbf

Amplitude g/lbf

40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET065 1 - 55 Hz, 0.0024 g/lbf PASS


1 - 184.0 Hz, 0.0473 g/lbf 2 - 70 Hz, 0.0015 g/lbf
2 - 188.5 Hz, 0.0394 g/lbf 3 - 110 Hz, 0.0085 g/lbf
3 - 153.5 Hz, 0.0369 g/lbf 4 - 140 Hz, 0.0149 g/lbf
80m 500m

400m
60m
1
300m
Amplitude g/lbf

Amplitude g/lbf

2
40m 3
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1047 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA066 1 - 55 Hz, 0.0010 g/lbf PASS


1 - 122.5 Hz, 0.0260 g/lbf 2 - 70 Hz, 0.0009 g/lbf
2 - 186.0 Hz, 0.0150 g/lbf 3 - 110 Hz, 0.0084 g/lbf
3 - 153.5 Hz, 0.0120 g/lbf 4 - 140 Hz, 0.0022 g/lbf
40m 500m

400m
30m
1
300m
Amplitude g/lbf

Amplitude g/lbf
20m
2 200m
3
10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER066 1 - 55 Hz, 0.0047 g/lbf PASS


1 - 99.0 Hz, 0.0662 g/lbf 2 - 70 Hz, 0.0025 g/lbf
2 - 131.0 Hz, 0.0577 g/lbf 3 - 110 Hz, 0.0024 g/lbf
3 - 65.0 Hz, 0.0464 g/lbf 4 - 140 Hz, 0.0054 g/lbf
80m 500m
1
2 400m
60m
3
300m
Amplitude g/lbf

Amplitude g/lbf

40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET066 1 - 55 Hz, 0.0020 g/lbf PASS


1 - 183.5 Hz, 0.0483 g/lbf 2 - 70 Hz, 0.0013 g/lbf
2 - 188.0 Hz, 0.0418 g/lbf 3 - 110 Hz, 0.0076 g/lbf
3 - 162.5 Hz, 0.0324 g/lbf 4 - 140 Hz, 0.0129 g/lbf
80m 500m

400m
60m
1
300m
Amplitude g/lbf

Amplitude g/lbf

2
40m
3
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1048 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA067 1 - 55 Hz, 0.0011 g/lbf PASS


1 - 122.5 Hz, 0.0276 g/lbf 2 - 70 Hz, 0.0009 g/lbf
2 - 153.5 Hz, 0.0175 g/lbf 3 - 110 Hz, 0.0094 g/lbf
3 - 185.0 Hz, 0.0142 g/lbf 4 - 140 Hz, 0.0026 g/lbf
40m 500m

400m
30m 1

300m
Amplitude g/lbf

Amplitude g/lbf
20m 2
3 200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER067 1 - 55 Hz, 0.0046 g/lbf PASS


1 - 99.0 Hz, 0.0547 g/lbf 2 - 70 Hz, 0.0025 g/lbf
2 - 131.0 Hz, 0.0504 g/lbf 3 - 110 Hz, 0.0022 g/lbf
3 - 65.0 Hz, 0.0446 g/lbf 4 - 140 Hz, 0.0053 g/lbf
80m 500m

400m
60m 1
2
3 300m
Amplitude g/lbf

Amplitude g/lbf

40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET067 1 - 55 Hz, 0.0018 g/lbf PASS


1 - 163.0 Hz, 0.0318 g/lbf 2 - 70 Hz, 0.0005 g/lbf
2 - 183.5 Hz, 0.0318 g/lbf 3 - 110 Hz, 0.0039 g/lbf
3 - 131.0 Hz, 0.0285 g/lbf 4 - 140 Hz, 0.0070 g/lbf
50m 500m

40m 400m
1 2
30m 3 300m
Amplitude g/lbf

Amplitude g/lbf

20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1049 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA068 1 - 55 Hz, 0.0011 g/lbf PASS


1 - 122.5 Hz, 0.0285 g/lbf 2 - 70 Hz, 0.0012 g/lbf
2 - 153.5 Hz, 0.0165 g/lbf 3 - 110 Hz, 0.0103 g/lbf
3 - 185.0 Hz, 0.0149 g/lbf 4 - 140 Hz, 0.0030 g/lbf
40m 500m

400m
30m 1

300m
Amplitude g/lbf

Amplitude g/lbf
20m
2
3 200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER068 1 - 55 Hz, 0.0047 g/lbf PASS


1 - 65.0 Hz, 0.0428 g/lbf 2 - 70 Hz, 0.0026 g/lbf
2 - 97.5 Hz, 0.0403 g/lbf 3 - 110 Hz, 0.0018 g/lbf
3 - 133.5 Hz, 0.0353 g/lbf 4 - 140 Hz, 0.0049 g/lbf
50m 500m
1
2
40m 400m
3

30m 300m
Amplitude g/lbf

Amplitude g/lbf

20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET068 1 - 55 Hz, 0.0011 g/lbf PASS


1 - 184.5 Hz, 0.0304 g/lbf 2 - 70 Hz, 0.0009 g/lbf
2 - 189.0 Hz, 0.0256 g/lbf 3 - 110 Hz, 0.0078 g/lbf
3 - 153.5 Hz, 0.0207 g/lbf 4 - 140 Hz, 0.0083 g/lbf
40m 500m

1 400m
30m
2
300m
Amplitude g/lbf

Amplitude g/lbf

3
20m
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1050 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA069 1 - 55 Hz, 0.0012 g/lbf PASS


1 - 122.5 Hz, 0.0273 g/lbf 2 - 70 Hz, 0.0011 g/lbf
2 - 153.5 Hz, 0.0170 g/lbf 3 - 110 Hz, 0.0103 g/lbf
3 - 184.0 Hz, 0.0138 g/lbf 4 - 140 Hz, 0.0031 g/lbf
40m 500m

400m
30m 1

300m
Amplitude g/lbf

Amplitude g/lbf
20m
2
3 200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER069 1 - 55 Hz, 0.0047 g/lbf PASS


1 - 97.5 Hz, 0.0473 g/lbf 2 - 70 Hz, 0.0023 g/lbf
2 - 133.5 Hz, 0.0448 g/lbf 3 - 110 Hz, 0.0029 g/lbf
3 - 65.0 Hz, 0.0385 g/lbf 4 - 140 Hz, 0.0048 g/lbf
50m 1 500m
2

40m 3 400m

30m 300m
Amplitude g/lbf

Amplitude g/lbf

20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET069 1 - 55 Hz, 0.0035 g/lbf PASS


1 - 184.0 Hz, 0.0913 g/lbf 2 - 70 Hz, 0.0048 g/lbf
2 - 188.5 Hz, 0.0829 g/lbf 3 - 110 Hz, 0.0203 g/lbf
3 - 162.0 Hz, 0.0636 g/lbf 4 - 140 Hz, 0.0288 g/lbf
200m 500m

400m

300m
Amplitude g/lbf

Amplitude g/lbf

100m 1
2
200m
3

100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1051 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA070 1 - 55 Hz, 0.0012 g/lbf PASS


1 - 122.5 Hz, 0.0291 g/lbf 2 - 70 Hz, 0.0017 g/lbf
2 - 185.5 Hz, 0.0217 g/lbf 3 - 110 Hz, 0.0120 g/lbf
3 - 153.5 Hz, 0.0147 g/lbf 4 - 140 Hz, 0.0044 g/lbf
100m 500m

400m

300m
Amplitude g/lbf

Amplitude g/lbf
50m
200m
1
2
3 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER070 1 - 55 Hz, 0.0055 g/lbf PASS


1 - 97.5 Hz, 0.0633 g/lbf 2 - 70 Hz, 0.0025 g/lbf
2 - 133.5 Hz, 0.0593 g/lbf 3 - 110 Hz, 0.0036 g/lbf
3 - 185.0 Hz, 0.0516 g/lbf 4 - 140 Hz, 0.0048 g/lbf
80m 500m

1
2 400m
60m
3
300m
Amplitude g/lbf

Amplitude g/lbf

40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET070 1 - 55 Hz, 0.0014 g/lbf PASS


1 - 186.5 Hz, 0.0412 g/lbf 2 - 70 Hz, 0.0018 g/lbf
2 - 191.5 Hz, 0.0326 g/lbf 3 - 110 Hz, 0.0087 g/lbf
3 - 190.5 Hz, 0.0317 g/lbf 4 - 140 Hz, 0.0116 g/lbf
80m 500m

400m
60m

300m
Amplitude g/lbf

Amplitude g/lbf

1
40m
32
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1052 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA071 1 - 55 Hz, 0.0011 g/lbf PASS


1 - 122.5 Hz, 0.0251 g/lbf 2 - 70 Hz, 0.0011 g/lbf
2 - 185.5 Hz, 0.0181 g/lbf 3 - 110 Hz, 0.0097 g/lbf
3 - 188.5 Hz, 0.0150 g/lbf 4 - 140 Hz, 0.0029 g/lbf
40m 500m

400m
30m
1
300m
Amplitude g/lbf

Amplitude g/lbf
20m 2
3 200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER071 1 - 55 Hz, 0.0053 g/lbf PASS


1 - 97.5 Hz, 0.0636 g/lbf 2 - 70 Hz, 0.0026 g/lbf
2 - 133.5 Hz, 0.0529 g/lbf 3 - 110 Hz, 0.0044 g/lbf
3 - 185.0 Hz, 0.0523 g/lbf 4 - 140 Hz, 0.0060 g/lbf
80m 500m

1
400m
60m
2 3
300m
Amplitude g/lbf

Amplitude g/lbf

40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET071 1 - 55 Hz, 0.0025 g/lbf PASS


1 - 184.0 Hz, 0.0537 g/lbf 2 - 70 Hz, 0.0019 g/lbf
2 - 159.0 Hz, 0.0388 g/lbf 3 - 110 Hz, 0.0086 g/lbf
3 - 155.0 Hz, 0.0333 g/lbf 4 - 140 Hz, 0.0139 g/lbf
80m 500m

400m
60m
1
300m
Amplitude g/lbf

Amplitude g/lbf

40m 2
3
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1053 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
TURBINE END SERIES LOOP RESPONSES

TEA072 1 - 55 Hz, 0.0011 g/lbf PASS


1 - 122.5 Hz, 0.0268 g/lbf 2 - 70 Hz, 0.0011 g/lbf
2 - 184.5 Hz, 0.0169 g/lbf 3 - 110 Hz, 0.0113 g/lbf
3 - 189.0 Hz, 0.0162 g/lbf 4 - 140 Hz, 0.0024 g/lbf
40m 500m

400m
30m
1
300m
Amplitude g/lbf

Amplitude g/lbf
20m 23
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER072 1 - 55 Hz, 0.0054 g/lbf PASS


1 - 97.5 Hz, 0.0615 g/lbf 2 - 70 Hz, 0.0028 g/lbf
2 - 133.5 Hz, 0.0457 g/lbf 3 - 110 Hz, 0.0038 g/lbf
3 - 185.0 Hz, 0.0422 g/lbf 4 - 140 Hz, 0.0062 g/lbf
80m 500m

1 400m
60m

2 300m
Amplitude g/lbf

Amplitude g/lbf

3
40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET072 1 - 55 Hz, 0.0017 g/lbf PASS


1 - 184.5 Hz, 0.0292 g/lbf 2 - 70 Hz, 0.0003 g/lbf
2 - 159.5 Hz, 0.0279 g/lbf 3 - 110 Hz, 0.0035 g/lbf
3 - 133.5 Hz, 0.0232 g/lbf 4 - 140 Hz, 0.0058 g/lbf
40m 500m

1 400m
30m 2
3 300m
Amplitude g/lbf

Amplitude g/lbf

20m
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1054 of 1653


Bump Test_As Found

GE Power Inspection & Life Extension Services


Endwinding Vibration Test Report

Enclosure 2
Collector End Series Loop Frequency Responses
(Amplitude versus Frequency)

GE Proprietary Information. This document contains proprietary information of the General Electric Company and
may not be used or disclosed to others, except with the written permission of General Electric Company. 8

Page 1055 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA004 1 - 55 Hz, 0.0015 g/lbf PASS


1 - 195.5 Hz, 0.0142 g/lbf 2 - 70 Hz, 0.0017 g/lbf
2 - 190.5 Hz, 0.0139 g/lbf 3 - 110 Hz, 0.0033 g/lbf
3 - 127.0 Hz, 0.0074 g/lbf 4 - 140 Hz, 0.0037 g/lbf
20m 500m

400m
15m 21

300m
Amplitude g/lbf

Amplitude g/lbf
10m
3 200m

5m
100m

1 2 5 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER004 1 - 55 Hz, 0.0081 g/lbf PASS


1 - 196.5 Hz, 0.0608 g/lbf 2 - 70 Hz, 0.0083 g/lbf
2 - 189.0 Hz, 0.0444 g/lbf 3 - 110 Hz, 0.0031 g/lbf
3 - 179.0 Hz, 0.0228 g/lbf 4 - 140 Hz, 0.0043 g/lbf
80m 500m

1 400m
60m

2 300m
Amplitude g/lbf

Amplitude g/lbf

40m
200m
3
20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET004 1 - 55 Hz, 0.0027 g/lbf PASS


1 - 199.0 Hz, 0.0231 g/lbf 2 - 70 Hz, 0.0022 g/lbf
2 - 188.0 Hz, 0.0227 g/lbf 3 - 110 Hz, 0.0080 g/lbf
3 - 189.5 Hz, 0.0221 g/lbf 4 - 140 Hz, 0.0095 g/lbf
40m 500m

400m
30m

23 300m
Amplitude g/lbf

Amplitude g/lbf

20m
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 50 60 80 100 120 135
Frequency - Hz Frequency - Hz

Page 1056 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA005 1 - 55 Hz, 0.0014 g/lbf PASS


1 - 195.0 Hz, 0.0146 g/lbf 2 - 70 Hz, 0.0018 g/lbf
2 - 190.5 Hz, 0.0127 g/lbf 3 - 110 Hz, 0.0027 g/lbf
3 - 169.0 Hz, 0.0059 g/lbf 4 - 140 Hz, 0.0031 g/lbf
20m 500m

1 400m
15m
2
300m
Amplitude g/lbf

Amplitude g/lbf
10m
200m
3
5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER005 1 - 55 Hz, 0.0061 g/lbf PASS


1 - 196.5 Hz, 0.0556 g/lbf 2 - 70 Hz, 0.0076 g/lbf
2 - 189.0 Hz, 0.0375 g/lbf 3 - 110 Hz, 0.0025 g/lbf
3 - 179.0 Hz, 0.0187 g/lbf 4 - 140 Hz, 0.0016 g/lbf
80m 500m

400m
60m 1

300m
Amplitude g/lbf

Amplitude g/lbf

40m 2
200m
3
20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET005 1 - 55 Hz, 0.0022 g/lbf PASS


1 - 197.5 Hz, 0.0398 g/lbf 2 - 70 Hz, 0.0039 g/lbf
2 - 195.0 Hz, 0.0383 g/lbf 3 - 110 Hz, 0.0071 g/lbf
3 - 189.0 Hz, 0.0314 g/lbf 4 - 140 Hz, 0.0123 g/lbf
40m 2 500m

3 400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf

20m
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1057 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA006 1 - 55 Hz, 0.0013 g/lbf PASS


1 - 194.5 Hz, 0.0144 g/lbf 2 - 70 Hz, 0.0018 g/lbf
2 - 190.0 Hz, 0.0125 g/lbf 3 - 110 Hz, 0.0029 g/lbf
3 - 169.0 Hz, 0.0074 g/lbf 4 - 140 Hz, 0.0037 g/lbf
20m 500m

400m
15m 1
2
300m
Amplitude g/lbf

Amplitude g/lbf
10m
3 200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER006 1 - 55 Hz, 0.0059 g/lbf PASS


1 - 197.0 Hz, 0.0374 g/lbf 2 - 70 Hz, 0.0081 g/lbf
2 - 189.0 Hz, 0.0264 g/lbf 3 - 110 Hz, 0.0035 g/lbf
3 - 129.0 Hz, 0.0169 g/lbf 4 - 140 Hz, 0.0037 g/lbf
40m 1 500m

400m
30m
2
300m
Amplitude g/lbf

Amplitude g/lbf

20m 3
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET006 1 - 55 Hz, 0.0017 g/lbf PASS


1 - 198.0 Hz, 0.0181 g/lbf 2 - 70 Hz, 0.0035 g/lbf
2 - 189.0 Hz, 0.0125 g/lbf 3 - 110 Hz, 0.0054 g/lbf
3 - 185.0 Hz, 0.0123 g/lbf 4 - 140 Hz, 0.0056 g/lbf
20m 500m

400m
15m
32
300m
Amplitude g/lbf

Amplitude g/lbf

10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1058 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA007 1 - 55 Hz, 0.0009 g/lbf PASS


1 - 194.5 Hz, 0.0140 g/lbf 2 - 70 Hz, 0.0013 g/lbf
2 - 189.5 Hz, 0.0128 g/lbf 3 - 110 Hz, 0.0033 g/lbf
3 - 184.5 Hz, 0.0098 g/lbf 4 - 140 Hz, 0.0042 g/lbf
50m 500m

40m 400m

30m 300m
Amplitude g/lbf

Amplitude g/lbf
20m 200m
21
3
10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER007 1 - 55 Hz, 0.0053 g/lbf PASS


1 - 134.5 Hz, 0.0242 g/lbf 2 - 70 Hz, 0.0092 g/lbf
2 - 129.0 Hz, 0.0189 g/lbf 3 - 110 Hz, 0.0052 g/lbf
3 - 95.5 Hz, 0.0135 g/lbf 4 - 140 Hz, 0.0097 g/lbf
40m 500m

400m
30m
1
300m
Amplitude g/lbf

Amplitude g/lbf

20m 2

3 200m

10m
100m

1 2 3
0 0
0 50 100 150 200 50 60 80 100 120 135
Frequency - Hz Frequency - Hz

CET007 1 - 55 Hz, 0.0017 g/lbf PASS


1 - 199.5 Hz, 0.0218 g/lbf 2 - 70 Hz, 0.0025 g/lbf
2 - 188.5 Hz, 0.0188 g/lbf 3 - 110 Hz, 0.0067 g/lbf
3 - 123.0 Hz, 0.0149 g/lbf 4 - 140 Hz, 0.0055 g/lbf
40m 500m

400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf

20m 2
3 200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1059 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA008 1 - 55 Hz, 0.0007 g/lbf PASS


1 - 194.5 Hz, 0.0122 g/lbf 2 - 70 Hz, 0.0012 g/lbf
2 - 189.5 Hz, 0.0109 g/lbf 3 - 110 Hz, 0.0029 g/lbf
3 - 184.0 Hz, 0.0080 g/lbf 4 - 140 Hz, 0.0031 g/lbf
20m 500m

400m
15m
1
2 300m
Amplitude g/lbf

Amplitude g/lbf
10m
3
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER008 1 - 55 Hz, 0.0053 g/lbf PASS


1 - 134.5 Hz, 0.0250 g/lbf 2 - 70 Hz, 0.0092 g/lbf
2 - 129.0 Hz, 0.0195 g/lbf 3 - 110 Hz, 0.0053 g/lbf
3 - 95.5 Hz, 0.0135 g/lbf 4 - 140 Hz, 0.0101 g/lbf
40m 500m

400m
30m
1
300m
Amplitude g/lbf

Amplitude g/lbf

2
20m
3 200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET008 1 - 55 Hz, 0.0017 g/lbf PASS


1 - 197.5 Hz, 0.0196 g/lbf 2 - 70 Hz, 0.0021 g/lbf
2 - 188.5 Hz, 0.0178 g/lbf 3 - 110 Hz, 0.0065 g/lbf
3 - 190.5 Hz, 0.0178 g/lbf 4 - 140 Hz, 0.0041 g/lbf
40m 500m

400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf

20m 23
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1060 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA009 1 - 55 Hz, 0.0008 g/lbf PASS


1 - 194.5 Hz, 0.0117 g/lbf 2 - 70 Hz, 0.0016 g/lbf
2 - 189.5 Hz, 0.0109 g/lbf 3 - 110 Hz, 0.0038 g/lbf
3 - 129.5 Hz, 0.0090 g/lbf 4 - 140 Hz, 0.0031 g/lbf
20m 500m

400m
15m
1 300m
2
Amplitude g/lbf

Amplitude g/lbf
10m 3
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER009 1 - 55 Hz, 0.0054 g/lbf PASS


1 - 134.5 Hz, 0.0288 g/lbf 2 - 70 Hz, 0.0096 g/lbf
2 - 129.0 Hz, 0.0219 g/lbf 3 - 110 Hz, 0.0067 g/lbf
3 - 95.5 Hz, 0.0148 g/lbf 4 - 140 Hz, 0.0118 g/lbf
40m 500m

1 400m
30m

2 300m
Amplitude g/lbf

Amplitude g/lbf

20m
3 200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET009 1 - 55 Hz, 0.0022 g/lbf PASS


1 - 127.5 Hz, 0.0193 g/lbf 2 - 70 Hz, 0.0020 g/lbf
2 - 123.5 Hz, 0.0191 g/lbf 3 - 110 Hz, 0.0067 g/lbf
3 - 135.5 Hz, 0.0180 g/lbf 4 - 140 Hz, 0.0055 g/lbf
20m 21 500m
3

400m
15m

300m
Amplitude g/lbf

Amplitude g/lbf

10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1061 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA010 1 - 55 Hz, 0.0012 g/lbf PASS


1 - 129.5 Hz, 0.0116 g/lbf 2 - 70 Hz, 0.0027 g/lbf
2 - 195.0 Hz, 0.0092 g/lbf 3 - 110 Hz, 0.0034 g/lbf
3 - 193.0 Hz, 0.0090 g/lbf 4 - 140 Hz, 0.0031 g/lbf
20m 500m

400m
15m
1 300m
Amplitude g/lbf

Amplitude g/lbf
10m 32
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER010 1 - 55 Hz, 0.0052 g/lbf PASS


1 - 134.5 Hz, 0.0315 g/lbf 2 - 70 Hz, 0.0095 g/lbf
2 - 129.0 Hz, 0.0247 g/lbf 3 - 110 Hz, 0.0078 g/lbf
3 - 95.5 Hz, 0.0149 g/lbf 4 - 140 Hz, 0.0127 g/lbf
40m 500m

1
400m
30m
2
300m
Amplitude g/lbf

Amplitude g/lbf

20m
3 200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET010 1 - 55 Hz, 0.0026 g/lbf PASS


1 - 135.5 Hz, 0.0275 g/lbf 2 - 70 Hz, 0.0017 g/lbf
2 - 127.5 Hz, 0.0246 g/lbf 3 - 110 Hz, 0.0065 g/lbf
3 - 124.0 Hz, 0.0222 g/lbf 4 - 140 Hz, 0.0110 g/lbf
40m 500m

400m
30m 1
2
3 300m
Amplitude g/lbf

Amplitude g/lbf

20m
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1062 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA011 1 - 55 Hz, 0.0013 g/lbf PASS


1 - 129.5 Hz, 0.0166 g/lbf 2 - 70 Hz, 0.0033 g/lbf
2 - 122.5 Hz, 0.0125 g/lbf 3 - 110 Hz, 0.0042 g/lbf
3 - 193.0 Hz, 0.0124 g/lbf 4 - 140 Hz, 0.0048 g/lbf
20m 500m
1
400m
15m
2 3
300m
Amplitude g/lbf

Amplitude g/lbf
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER011 1 - 55 Hz, 0.0058 g/lbf PASS


1 - 197.0 Hz, 0.0365 g/lbf 2 - 70 Hz, 0.0094 g/lbf
2 - 134.5 Hz, 0.0361 g/lbf 3 - 110 Hz, 0.0103 g/lbf
3 - 128.5 Hz, 0.0315 g/lbf 4 - 140 Hz, 0.0129 g/lbf
40m 1 500m
2
3
400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf

20m
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET011 1 - 55 Hz, 0.0028 g/lbf PASS


1 - 127.0 Hz, 0.0253 g/lbf 2 - 70 Hz, 0.0020 g/lbf
2 - 123.5 Hz, 0.0246 g/lbf 3 - 110 Hz, 0.0082 g/lbf
3 - 135.5 Hz, 0.0209 g/lbf 4 - 140 Hz, 0.0065 g/lbf
40m 500m

400m
30m
21
300m
Amplitude g/lbf

Amplitude g/lbf

3
20m
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1063 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA012 1 - 55 Hz, 0.0017 g/lbf PASS


1 - 129.5 Hz, 0.0239 g/lbf 2 - 70 Hz, 0.0036 g/lbf
2 - 189.5 Hz, 0.0221 g/lbf 3 - 110 Hz, 0.0065 g/lbf
3 - 197.0 Hz, 0.0217 g/lbf 4 - 140 Hz, 0.0057 g/lbf
40m 500m

400m
30m
1
23 300m
Amplitude g/lbf

Amplitude g/lbf
20m
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER012 1 - 55 Hz, 0.0058 g/lbf PASS


1 - 197.0 Hz, 0.0675 g/lbf 2 - 70 Hz, 0.0086 g/lbf
2 - 191.5 Hz, 0.0421 g/lbf 3 - 110 Hz, 0.0117 g/lbf
3 - 127.5 Hz, 0.0315 g/lbf 4 - 140 Hz, 0.0091 g/lbf
80m 500m
1
400m
60m

300m
Amplitude g/lbf

Amplitude g/lbf

2
40m
3
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET012 1 - 55 Hz, 0.0027 g/lbf PASS


1 - 198.5 Hz, 0.0272 g/lbf 2 - 70 Hz, 0.0018 g/lbf
2 - 127.5 Hz, 0.0230 g/lbf 3 - 110 Hz, 0.0072 g/lbf
3 - 126.5 Hz, 0.0230 g/lbf 4 - 140 Hz, 0.0060 g/lbf
40m 500m

400m
30m
32 300m
Amplitude g/lbf

Amplitude g/lbf

20m
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1064 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA016 1 - 55 Hz, 0.0017 g/lbf PASS


1 - 193.0 Hz, 0.0370 g/lbf 2 - 70 Hz, 0.0030 g/lbf
2 - 189.0 Hz, 0.0317 g/lbf 3 - 110 Hz, 0.0068 g/lbf
3 - 185.0 Hz, 0.0316 g/lbf 4 - 140 Hz, 0.0072 g/lbf
40m 1 500m

32
400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf
20m
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER016 1 - 55 Hz, 0.0045 g/lbf PASS


1 - 198.5 Hz, 0.0817 g/lbf 2 - 70 Hz, 0.0107 g/lbf
2 - 189.0 Hz, 0.0595 g/lbf 3 - 110 Hz, 0.0087 g/lbf
3 - 185.5 Hz, 0.0541 g/lbf 4 - 140 Hz, 0.0057 g/lbf
100m 500m

400m

2
3 300m
Amplitude g/lbf

Amplitude g/lbf

50m
200m

100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET016 1 - 55 Hz, 0.0022 g/lbf PASS


1 - 192.0 Hz, 0.0339 g/lbf 2 - 70 Hz, 0.0031 g/lbf
2 - 194.5 Hz, 0.0328 g/lbf 3 - 110 Hz, 0.0076 g/lbf
3 - 184.5 Hz, 0.0280 g/lbf 4 - 140 Hz, 0.0075 g/lbf
40m 500m
12
400m
30m 3

300m
Amplitude g/lbf

Amplitude g/lbf

20m
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1065 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA017 1 - 55 Hz, 0.0012 g/lbf PASS


1 - 194.0 Hz, 0.0203 g/lbf 2 - 70 Hz, 0.0031 g/lbf
2 - 197.5 Hz, 0.0167 g/lbf 3 - 110 Hz, 0.0038 g/lbf
3 - 186.0 Hz, 0.0158 g/lbf 4 - 140 Hz, 0.0025 g/lbf
40m 500m

400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf
1
20m
3 2
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER017 1 - 55 Hz, 0.0039 g/lbf PASS


1 - 198.5 Hz, 0.0511 g/lbf 2 - 70 Hz, 0.0099 g/lbf
2 - 189.0 Hz, 0.0391 g/lbf 3 - 110 Hz, 0.0067 g/lbf
3 - 185.5 Hz, 0.0364 g/lbf 4 - 140 Hz, 0.0052 g/lbf
80m 500m

400m
60m

300m
Amplitude g/lbf

Amplitude g/lbf

2
40m 3
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET017 1 - 55 Hz, 0.0016 g/lbf PASS


1 - 196.0 Hz, 0.0173 g/lbf 2 - 70 Hz, 0.0011 g/lbf
2 - 192.5 Hz, 0.0143 g/lbf 3 - 110 Hz, 0.0048 g/lbf
3 - 127.5 Hz, 0.0094 g/lbf 4 - 140 Hz, 0.0036 g/lbf
20m 500m
1
400m
15m 2

300m
Amplitude g/lbf

Amplitude g/lbf

10m 3
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1066 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA018 1 - 55 Hz, 0.0010 g/lbf PASS


1 - 194.5 Hz, 0.0148 g/lbf 2 - 70 Hz, 0.0026 g/lbf
2 - 186.0 Hz, 0.0113 g/lbf 3 - 110 Hz, 0.0034 g/lbf
3 - 175.0 Hz, 0.0094 g/lbf 4 - 140 Hz, 0.0017 g/lbf
20m 500m

1 400m
15m

2 300m
Amplitude g/lbf

Amplitude g/lbf
10m 3
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER018 1 - 55 Hz, 0.0039 g/lbf PASS


1 - 198.5 Hz, 0.0309 g/lbf 2 - 70 Hz, 0.0105 g/lbf
2 - 189.0 Hz, 0.0218 g/lbf 3 - 110 Hz, 0.0069 g/lbf
3 - 186.0 Hz, 0.0189 g/lbf 4 - 140 Hz, 0.0067 g/lbf
40m 500m

400m
30m

2 300m
Amplitude g/lbf

Amplitude g/lbf

20m 3

200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET018 1 - 55 Hz, 0.0015 g/lbf PASS


1 - 195.5 Hz, 0.0180 g/lbf 2 - 70 Hz, 0.0009 g/lbf
2 - 192.0 Hz, 0.0155 g/lbf 3 - 110 Hz, 0.0058 g/lbf
3 - 129.5 Hz, 0.0117 g/lbf 4 - 140 Hz, 0.0041 g/lbf
20m 500m
1
2 400m
15m
3
300m
Amplitude g/lbf

Amplitude g/lbf

10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1067 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA019 1 - 55 Hz, 0.0008 g/lbf PASS


1 - 194.5 Hz, 0.0163 g/lbf 2 - 70 Hz, 0.0012 g/lbf
2 - 193.0 Hz, 0.0162 g/lbf 3 - 110 Hz, 0.0040 g/lbf
3 - 186.0 Hz, 0.0126 g/lbf 4 - 140 Hz, 0.0029 g/lbf
20m 500m

21
400m
15m
3
300m
Amplitude g/lbf

Amplitude g/lbf
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER019 1 - 55 Hz, 0.0036 g/lbf PASS


1 - 126.0 Hz, 0.0169 g/lbf 2 - 70 Hz, 0.0101 g/lbf
2 - 69.0 Hz, 0.0146 g/lbf 3 - 110 Hz, 0.0062 g/lbf
3 - 84.0 Hz, 0.0138 g/lbf 4 - 140 Hz, 0.0076 g/lbf
20m 500m
1
2 400m
15m 3

300m
Amplitude g/lbf

Amplitude g/lbf

10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET019 1 - 55 Hz, 0.0015 g/lbf PASS


1 - 196.0 Hz, 0.0158 g/lbf 2 - 70 Hz, 0.0008 g/lbf
2 - 197.0 Hz, 0.0150 g/lbf 3 - 110 Hz, 0.0051 g/lbf
3 - 192.0 Hz, 0.0139 g/lbf 4 - 140 Hz, 0.0051 g/lbf
20m 500m

1
2 400m
15m 3

300m
Amplitude g/lbf

Amplitude g/lbf

10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1068 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA020 1 - 55 Hz, 0.0007 g/lbf PASS


1 - 193.0 Hz, 0.0136 g/lbf 2 - 70 Hz, 0.0011 g/lbf
2 - 194.5 Hz, 0.0136 g/lbf 3 - 110 Hz, 0.0038 g/lbf
3 - 196.0 Hz, 0.0134 g/lbf 4 - 140 Hz, 0.0032 g/lbf
20m 500m

400m
15m 123

300m
Amplitude g/lbf

Amplitude g/lbf
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER020 1 - 55 Hz, 0.0040 g/lbf PASS


1 - 126.0 Hz, 0.0214 g/lbf 2 - 70 Hz, 0.0105 g/lbf
2 - 69.0 Hz, 0.0155 g/lbf 3 - 110 Hz, 0.0067 g/lbf
3 - 129.5 Hz, 0.0145 g/lbf 4 - 140 Hz, 0.0090 g/lbf
40m 500m

400m
30m

1 300m
Amplitude g/lbf

Amplitude g/lbf

20m
2 3 200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET020 1 - 55 Hz, 0.0016 g/lbf PASS


1 - 129.5 Hz, 0.0133 g/lbf 2 - 70 Hz, 0.0009 g/lbf
2 - 135.5 Hz, 0.0132 g/lbf 3 - 110 Hz, 0.0051 g/lbf
3 - 195.5 Hz, 0.0125 g/lbf 4 - 140 Hz, 0.0052 g/lbf
20m 500m

400m
15m
12
3
300m
Amplitude g/lbf

Amplitude g/lbf

10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1069 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA021 1 - 55 Hz, 0.0008 g/lbf PASS


1 - 134.5 Hz, 0.0162 g/lbf 2 - 70 Hz, 0.0010 g/lbf
2 - 196.5 Hz, 0.0131 g/lbf 3 - 110 Hz, 0.0047 g/lbf
3 - 195.0 Hz, 0.0130 g/lbf 4 - 140 Hz, 0.0050 g/lbf
20m 500m

1
400m
15m
32
300m
Amplitude g/lbf

Amplitude g/lbf
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER021 1 - 55 Hz, 0.0038 g/lbf PASS


1 - 126.5 Hz, 0.0196 g/lbf 2 - 70 Hz, 0.0102 g/lbf
2 - 127.5 Hz, 0.0190 g/lbf 3 - 110 Hz, 0.0061 g/lbf
3 - 69.0 Hz, 0.0148 g/lbf 4 - 140 Hz, 0.0082 g/lbf
12
20m 500m

3 400m
15m

300m
Amplitude g/lbf

Amplitude g/lbf

10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET021 1 - 55 Hz, 0.0021 g/lbf PASS


1 - 130.0 Hz, 0.0164 g/lbf 2 - 70 Hz, 0.0032 g/lbf
2 - 127.0 Hz, 0.0157 g/lbf 3 - 110 Hz, 0.0062 g/lbf
3 - 135.5 Hz, 0.0154 g/lbf 4 - 140 Hz, 0.0065 g/lbf
20m 500m
1
2 3 400m
15m

300m
Amplitude g/lbf

Amplitude g/lbf

10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1070 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA022 1 - 55 Hz, 0.0009 g/lbf PASS


1 - 134.5 Hz, 0.0168 g/lbf 2 - 70 Hz, 0.0016 g/lbf
2 - 132.5 Hz, 0.0129 g/lbf 3 - 110 Hz, 0.0045 g/lbf
3 - 137.5 Hz, 0.0113 g/lbf 4 - 140 Hz, 0.0050 g/lbf
20m 500m
1
400m
15m
2
3 300m
Amplitude g/lbf

Amplitude g/lbf
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER022 1 - 55 Hz, 0.0039 g/lbf PASS


1 - 199.0 Hz, 0.0325 g/lbf 2 - 70 Hz, 0.0097 g/lbf
2 - 126.5 Hz, 0.0226 g/lbf 3 - 110 Hz, 0.0066 g/lbf
3 - 191.5 Hz, 0.0181 g/lbf 4 - 140 Hz, 0.0072 g/lbf
40m 500m

400m
30m

2 300m
Amplitude g/lbf

Amplitude g/lbf

20m 3
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET022 1 - 55 Hz, 0.0022 g/lbf PASS


1 - 130.0 Hz, 0.0171 g/lbf 2 - 70 Hz, 0.0036 g/lbf
2 - 127.0 Hz, 0.0160 g/lbf 3 - 110 Hz, 0.0063 g/lbf
3 - 135.5 Hz, 0.0151 g/lbf 4 - 140 Hz, 0.0062 g/lbf
20m 500m
1
2
3 400m
15m

300m
Amplitude g/lbf

Amplitude g/lbf

10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1071 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA023 1 - 55 Hz, 0.0011 g/lbf PASS


1 - 134.5 Hz, 0.0219 g/lbf 2 - 70 Hz, 0.0016 g/lbf
2 - 132.5 Hz, 0.0171 g/lbf 3 - 110 Hz, 0.0056 g/lbf
3 - 137.5 Hz, 0.0159 g/lbf 4 - 140 Hz, 0.0072 g/lbf
40m 500m

400m
30m

1 300m
Amplitude g/lbf

Amplitude g/lbf
20m 23
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER023 1 - 55 Hz, 0.0038 g/lbf PASS


1 - 199.0 Hz, 0.0664 g/lbf 2 - 70 Hz, 0.0089 g/lbf
2 - 189.5 Hz, 0.0387 g/lbf 3 - 110 Hz, 0.0076 g/lbf
3 - 191.5 Hz, 0.0385 g/lbf 4 - 140 Hz, 0.0047 g/lbf
80m 500m

400m
60m

300m
Amplitude g/lbf

Amplitude g/lbf

23
40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET023 1 - 55 Hz, 0.0037 g/lbf PASS


1 - 126.5 Hz, 0.0256 g/lbf 2 - 70 Hz, 0.0075 g/lbf
2 - 123.0 Hz, 0.0220 g/lbf 3 - 110 Hz, 0.0092 g/lbf
3 - 129.5 Hz, 0.0200 g/lbf 4 - 140 Hz, 0.0085 g/lbf
40m 500m

400m
30m
1
2 300m
Amplitude g/lbf

Amplitude g/lbf

3
20m
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1072 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA024 1 - 55 Hz, 0.0014 g/lbf PASS


1 - 134.5 Hz, 0.0280 g/lbf 2 - 70 Hz, 0.0019 g/lbf
2 - 132.5 Hz, 0.0221 g/lbf 3 - 110 Hz, 0.0076 g/lbf
3 - 129.0 Hz, 0.0193 g/lbf 4 - 140 Hz, 0.0095 g/lbf
40m 500m

400m
30m 1

2 300m
Amplitude g/lbf

Amplitude g/lbf
20m 3

200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER024 1 - 55 Hz, 0.0039 g/lbf PASS


1 - 198.5 Hz, 0.1123 g/lbf 2 - 70 Hz, 0.0084 g/lbf
2 - 189.5 Hz, 0.0681 g/lbf 3 - 110 Hz, 0.0098 g/lbf
3 - 191.0 Hz, 0.0659 g/lbf 4 - 140 Hz, 0.0028 g/lbf
200m 500m

400m

300m
Amplitude g/lbf

Amplitude g/lbf

100m
23 200m

100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET024 1 - 55 Hz, 0.0034 g/lbf PASS


1 - 126.5 Hz, 0.0249 g/lbf 2 - 70 Hz, 0.0070 g/lbf
2 - 123.0 Hz, 0.0215 g/lbf 3 - 110 Hz, 0.0087 g/lbf
3 - 130.0 Hz, 0.0190 g/lbf 4 - 140 Hz, 0.0077 g/lbf
40m 500m

400m
30m
1
2 300m
Amplitude g/lbf

Amplitude g/lbf

20m 3
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1073 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA028 1 - 55 Hz, 0.0018 g/lbf PASS


1 - 198.0 Hz, 0.0125 g/lbf 2 - 70 Hz, 0.0018 g/lbf
2 - 196.0 Hz, 0.0124 g/lbf 3 - 110 Hz, 0.0025 g/lbf
3 - 134.5 Hz, 0.0094 g/lbf 4 - 140 Hz, 0.0022 g/lbf
20m 500m

400m
15m
2
300m
Amplitude g/lbf

Amplitude g/lbf
10m 3
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER028 1 - 55 Hz, 0.0020 g/lbf PASS


1 - 189.5 Hz, 0.0355 g/lbf 2 - 70 Hz, 0.0040 g/lbf
2 - 194.5 Hz, 0.0296 g/lbf 3 - 110 Hz, 0.0070 g/lbf
3 - 171.0 Hz, 0.0212 g/lbf 4 - 140 Hz, 0.0072 g/lbf
40m 500m
1

2 400m
30m

3 300m
Amplitude g/lbf

Amplitude g/lbf

20m
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET028 1 - 55 Hz, 0.0019 g/lbf PASS


1 - 188.5 Hz, 0.0218 g/lbf 2 - 70 Hz, 0.0030 g/lbf
2 - 178.5 Hz, 0.0159 g/lbf 3 - 110 Hz, 0.0065 g/lbf
3 - 197.0 Hz, 0.0133 g/lbf 4 - 140 Hz, 0.0048 g/lbf
40m 500m

400m
30m

1 300m
Amplitude g/lbf

Amplitude g/lbf

20m
2
3 200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1074 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA029 1 - 55 Hz, 0.0015 g/lbf PASS


1 - 194.5 Hz, 0.0094 g/lbf 2 - 70 Hz, 0.0017 g/lbf
2 - 196.0 Hz, 0.0092 g/lbf 3 - 110 Hz, 0.0017 g/lbf
3 - 197.5 Hz, 0.0091 g/lbf 4 - 140 Hz, 0.0016 g/lbf
10m 123 500m

8m 400m

6m 300m
Amplitude g/lbf

Amplitude g/lbf
4m 200m

2m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER029 1 - 55 Hz, 0.0027 g/lbf PASS


1 - 190.0 Hz, 0.0261 g/lbf 2 - 70 Hz, 0.0044 g/lbf
2 - 195.0 Hz, 0.0231 g/lbf 3 - 110 Hz, 0.0067 g/lbf
3 - 171.0 Hz, 0.0164 g/lbf 4 - 140 Hz, 0.0064 g/lbf
40m 500m

400m
30m
1
2 300m
Amplitude g/lbf

Amplitude g/lbf

20m
3
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET029 1 - 55 Hz, 0.0018 g/lbf PASS


1 - 188.0 Hz, 0.0129 g/lbf 2 - 70 Hz, 0.0029 g/lbf
2 - 194.0 Hz, 0.0102 g/lbf 3 - 110 Hz, 0.0055 g/lbf
3 - 177.0 Hz, 0.0089 g/lbf 4 - 140 Hz, 0.0041 g/lbf
20m 500m

400m
15m
1
300m
Amplitude g/lbf

Amplitude g/lbf

2
10m 3
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1075 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA030 1 - 55 Hz, 0.0015 g/lbf PASS


1 - 194.5 Hz, 0.0093 g/lbf 2 - 70 Hz, 0.0017 g/lbf
2 - 197.5 Hz, 0.0077 g/lbf 3 - 110 Hz, 0.0019 g/lbf
3 - 134.5 Hz, 0.0061 g/lbf 4 - 140 Hz, 0.0015 g/lbf
10m 1 500m

8m 2 400m

3
6m 300m
Amplitude g/lbf

Amplitude g/lbf
4m 200m

2m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER030 1 - 55 Hz, 0.0029 g/lbf PASS


1 - 127.5 Hz, 0.0130 g/lbf 2 - 70 Hz, 0.0043 g/lbf
2 - 136.5 Hz, 0.0129 g/lbf 3 - 110 Hz, 0.0061 g/lbf
3 - 190.0 Hz, 0.0126 g/lbf 4 - 140 Hz, 0.0065 g/lbf
40m 500m

400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf

20m

1 2 200m
3
10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET030 1 - 55 Hz, 0.0011 g/lbf PASS


1 - 155.5 Hz, 0.0125 g/lbf 2 - 70 Hz, 0.0025 g/lbf
2 - 156.5 Hz, 0.0124 g/lbf 3 - 110 Hz, 0.0027 g/lbf
3 - 159.0 Hz, 0.0121 g/lbf 4 - 140 Hz, 0.0066 g/lbf
20m 500m

400m
15m
123
300m
Amplitude g/lbf

Amplitude g/lbf

10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1076 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA031 1 - 55 Hz, 0.0012 g/lbf PASS


1 - 194.5 Hz, 0.0095 g/lbf 2 - 70 Hz, 0.0012 g/lbf
2 - 190.0 Hz, 0.0065 g/lbf 3 - 110 Hz, 0.0022 g/lbf
3 - 197.5 Hz, 0.0065 g/lbf 4 - 140 Hz, 0.0017 g/lbf
10m 1 500m

8m 400m
2 3
6m 300m
Amplitude g/lbf

Amplitude g/lbf
4m 200m

2m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER031 1 - 55 Hz, 0.0032 g/lbf PASS


1 - 127.5 Hz, 0.0156 g/lbf 2 - 70 Hz, 0.0044 g/lbf
2 - 136.5 Hz, 0.0153 g/lbf 3 - 110 Hz, 0.0064 g/lbf
3 - 123.5 Hz, 0.0127 g/lbf 4 - 140 Hz, 0.0081 g/lbf
20m 500m

1 2 400m
15m
3
300m
Amplitude g/lbf

Amplitude g/lbf

10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET031 1 - 55 Hz, 0.0013 g/lbf PASS


1 - 129.5 Hz, 0.0076 g/lbf 2 - 70 Hz, 0.0021 g/lbf
2 - 196.5 Hz, 0.0072 g/lbf 3 - 110 Hz, 0.0054 g/lbf
3 - 187.5 Hz, 0.0070 g/lbf 4 - 140 Hz, 0.0039 g/lbf
20m 500m

400m
15m

300m
Amplitude g/lbf

Amplitude g/lbf

10m
1 3 2 200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1077 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA032 1 - 55 Hz, 0.0009 g/lbf PASS


1 - 194.5 Hz, 0.0096 g/lbf 2 - 70 Hz, 0.0009 g/lbf
2 - 190.0 Hz, 0.0068 g/lbf 3 - 110 Hz, 0.0028 g/lbf
3 - 134.0 Hz, 0.0064 g/lbf 4 - 140 Hz, 0.0025 g/lbf
10m 1 500m

8m 400m
2
3
6m 300m
Amplitude g/lbf

Amplitude g/lbf
4m 200m

2m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER032 1 - 55 Hz, 0.0034 g/lbf PASS


1 - 127.5 Hz, 0.0152 g/lbf 2 - 70 Hz, 0.0045 g/lbf
2 - 136.5 Hz, 0.0145 g/lbf 3 - 110 Hz, 0.0063 g/lbf
3 - 123.5 Hz, 0.0116 g/lbf 4 - 140 Hz, 0.0086 g/lbf
20m 500m

1 2 400m
15m
3
300m
Amplitude g/lbf

Amplitude g/lbf

10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET032 1 - 55 Hz, 0.0016 g/lbf PASS


1 - 127.5 Hz, 0.0155 g/lbf 2 - 70 Hz, 0.0034 g/lbf
2 - 157.0 Hz, 0.0115 g/lbf 3 - 110 Hz, 0.0020 g/lbf
3 - 123.5 Hz, 0.0114 g/lbf 4 - 140 Hz, 0.0048 g/lbf
20m 500m

1 400m
15m

3 2 300m
Amplitude g/lbf

Amplitude g/lbf

10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1078 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA033 1 - 55 Hz, 0.0009 g/lbf PASS


1 - 194.5 Hz, 0.0093 g/lbf 2 - 70 Hz, 0.0012 g/lbf
2 - 190.0 Hz, 0.0072 g/lbf 3 - 110 Hz, 0.0036 g/lbf
3 - 162.5 Hz, 0.0068 g/lbf 4 - 140 Hz, 0.0033 g/lbf
10m 1 500m

8m 400m
2
3

6m 300m
Amplitude g/lbf

Amplitude g/lbf
4m 200m

2m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER033 1 - 55 Hz, 0.0037 g/lbf PASS


1 - 127.5 Hz, 0.0170 g/lbf 2 - 70 Hz, 0.0047 g/lbf
2 - 136.5 Hz, 0.0151 g/lbf 3 - 110 Hz, 0.0069 g/lbf
3 - 123.5 Hz, 0.0126 g/lbf 4 - 140 Hz, 0.0092 g/lbf
20m 500m
1
2 400m
15m
3
300m
Amplitude g/lbf

Amplitude g/lbf

10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET033 1 - 55 Hz, 0.0005 g/lbf PASS


1 - 196.0 Hz, 0.0104 g/lbf 2 - 70 Hz, 0.0009 g/lbf
2 - 198.5 Hz, 0.0103 g/lbf 3 - 110 Hz, 0.0046 g/lbf
3 - 128.5 Hz, 0.0088 g/lbf 4 - 140 Hz, 0.0053 g/lbf
20m 500m

400m
15m

300m
Amplitude g/lbf

Amplitude g/lbf

1
10m 3
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1079 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA034 1 - 55 Hz, 0.0013 g/lbf PASS


1 - 129.0 Hz, 0.0082 g/lbf 2 - 70 Hz, 0.0017 g/lbf
2 - 195.0 Hz, 0.0072 g/lbf 3 - 110 Hz, 0.0043 g/lbf
3 - 162.5 Hz, 0.0071 g/lbf 4 - 140 Hz, 0.0036 g/lbf
10m 500m
1
8m 400m
3 2

6m 300m
Amplitude g/lbf

Amplitude g/lbf
4m 200m

2m 100m

1 2 3 4
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER034 1 - 55 Hz, 0.0040 g/lbf PASS


1 - 127.5 Hz, 0.0169 g/lbf 2 - 70 Hz, 0.0047 g/lbf
2 - 129.0 Hz, 0.0148 g/lbf 3 - 110 Hz, 0.0069 g/lbf
3 - 137.0 Hz, 0.0131 g/lbf 4 - 140 Hz, 0.0080 g/lbf
20m 500m
1
2 400m
15m
3
300m
Amplitude g/lbf

Amplitude g/lbf

10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET034 1 - 55 Hz, 0.0027 g/lbf PASS


1 - 190.5 Hz, 0.0198 g/lbf 2 - 70 Hz, 0.0035 g/lbf
2 - 127.5 Hz, 0.0184 g/lbf 3 - 110 Hz, 0.0030 g/lbf
3 - 123.5 Hz, 0.0138 g/lbf 1 4 - 140 Hz, 0.0045 g/lbf
20m 2 500m

400m
15m 3

300m
Amplitude g/lbf

Amplitude g/lbf

10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1080 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA035 1 - 55 Hz, 0.0015 g/lbf PASS


1 - 129.5 Hz, 0.0104 g/lbf 2 - 70 Hz, 0.0020 g/lbf
2 - 162.5 Hz, 0.0080 g/lbf 3 - 110 Hz, 0.0053 g/lbf
3 - 156.5 Hz, 0.0067 g/lbf 4 - 140 Hz, 0.0044 g/lbf
20m 500m

400m
15m

300m
Amplitude g/lbf

Amplitude g/lbf
1
10m
2
3 200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER035 1 - 55 Hz, 0.0042 g/lbf PASS


1 - 199.5 Hz, 0.0193 g/lbf 2 - 70 Hz, 0.0046 g/lbf
2 - 190.0 Hz, 0.0187 g/lbf 3 - 110 Hz, 0.0071 g/lbf
3 - 196.5 Hz, 0.0175 g/lbf 4 - 140 Hz, 0.0064 g/lbf
20m 2 500m
3

400m
15m

300m
Amplitude g/lbf

Amplitude g/lbf

10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET035 1 - 55 Hz, 0.0004 g/lbf PASS


1 - 195.5 Hz, 0.0138 g/lbf 2 - 70 Hz, 0.0010 g/lbf
2 - 197.5 Hz, 0.0123 g/lbf 3 - 110 Hz, 0.0040 g/lbf
3 - 192.5 Hz, 0.0118 g/lbf 4 - 140 Hz, 0.0063 g/lbf
20m 500m

400m
15m 1
32
300m
Amplitude g/lbf

Amplitude g/lbf

10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1081 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA036 1 - 55 Hz, 0.0016 g/lbf PASS


1 - 129.5 Hz, 0.0128 g/lbf 2 - 70 Hz, 0.0024 g/lbf
2 - 122.5 Hz, 0.0105 g/lbf 3 - 110 Hz, 0.0067 g/lbf
3 - 163.0 Hz, 0.0101 g/lbf 4 - 140 Hz, 0.0062 g/lbf
20m 500m

400m
15m
1
300m
Amplitude g/lbf

Amplitude g/lbf
2 3
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER036 1 - 55 Hz, 0.0049 g/lbf PASS


1 - 189.5 Hz, 0.0315 g/lbf 2 - 70 Hz, 0.0051 g/lbf
2 - 196.5 Hz, 0.0295 g/lbf 3 - 110 Hz, 0.0085 g/lbf
3 - 194.5 Hz, 0.0289 g/lbf 4 - 140 Hz, 0.0046 g/lbf
40m 500m

1
32 400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf

20m
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET036 1 - 55 Hz, 0.0038 g/lbf PASS


1 - 190.0 Hz, 0.0447 g/lbf 2 - 70 Hz, 0.0048 g/lbf
2 - 197.0 Hz, 0.0235 g/lbf 3 - 110 Hz, 0.0054 g/lbf
3 - 127.5 Hz, 0.0219 g/lbf 4 - 140 Hz, 0.0038 g/lbf
400m 500m

400m
300m

300m
Amplitude g/lbf

Amplitude g/lbf

200m
200m

100m
100m
1
3 2
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1082 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA040 1 - 55 Hz, 0.0014 g/lbf PASS


1 - 189.0 Hz, 0.0079 g/lbf 2 - 70 Hz, 0.0027 g/lbf
2 - 114.0 Hz, 0.0074 g/lbf 3 - 110 Hz, 0.0049 g/lbf
3 - 117.0 Hz, 0.0074 g/lbf 1 4 - 140 Hz, 0.0039 g/lbf
8m 23 500m

400m
6m

300m
Amplitude g/lbf

Amplitude g/lbf
4m
200m

2m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER040 1 - 55 Hz, 0.0045 g/lbf PASS


1 - 198.0 Hz, 0.0204 g/lbf 2 - 70 Hz, 0.0051 g/lbf
2 - 191.5 Hz, 0.0191 g/lbf 3 - 110 Hz, 0.0024 g/lbf
3 - 188.0 Hz, 0.0179 g/lbf 4 - 140 Hz, 0.0092 g/lbf
200m 500m

400m

300m
Amplitude g/lbf

Amplitude g/lbf

100m
200m

100m
32
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET040 1 - 55 Hz, 0.0009 g/lbf PASS


1 - 186.5 Hz, 0.0098 g/lbf 2 - 70 Hz, 0.0015 g/lbf
2 - 197.5 Hz, 0.0091 g/lbf 3 - 110 Hz, 0.0029 g/lbf
3 - 181.5 Hz, 0.0088 g/lbf 4 - 140 Hz, 0.0053 g/lbf
40m 500m

400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf

20m
200m

10m 31 2
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1083 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA041 1 - 55 Hz, 0.0011 g/lbf PASS


1 - 189.0 Hz, 0.0088 g/lbf 2 - 70 Hz, 0.0022 g/lbf
2 - 131.5 Hz, 0.0074 g/lbf 3 - 110 Hz, 0.0040 g/lbf
3 - 134.5 Hz, 0.0068 g/lbf 4 - 140 Hz, 0.0025 g/lbf
10m 500m
1

8m 2 400m
3

6m 300m
Amplitude g/lbf

Amplitude g/lbf
4m 200m

2m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER041 1 - 55 Hz, 0.0037 g/lbf PASS


1 - 199.0 Hz, 0.0150 g/lbf 2 - 70 Hz, 0.0054 g/lbf
2 - 178.0 Hz, 0.0132 g/lbf 3 - 110 Hz, 0.0021 g/lbf
3 - 163.0 Hz, 0.0127 g/lbf 4 - 140 Hz, 0.0104 g/lbf
20m 500m

400m
15m
3 2
300m
Amplitude g/lbf

Amplitude g/lbf

10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET041 1 - 55 Hz, 0.0009 g/lbf PASS


1 - 187.0 Hz, 0.0096 g/lbf 2 - 70 Hz, 0.0015 g/lbf
2 - 198.0 Hz, 0.0088 g/lbf 3 - 110 Hz, 0.0026 g/lbf
3 - 155.0 Hz, 0.0080 g/lbf 4 - 140 Hz, 0.0049 g/lbf
10m 1 500m
2
3
8m 400m

6m 300m
Amplitude g/lbf

Amplitude g/lbf

4m 200m

2m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1084 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA042 1 - 55 Hz, 0.0010 g/lbf PASS


1 - 189.0 Hz, 0.0089 g/lbf 2 - 70 Hz, 0.0021 g/lbf
2 - 131.5 Hz, 0.0076 g/lbf 3 - 110 Hz, 0.0033 g/lbf
3 - 191.5 Hz, 0.0073 g/lbf 4 - 140 Hz, 0.0020 g/lbf
10m 500m
1

8m 2 3 400m

6m 300m
Amplitude g/lbf

Amplitude g/lbf
4m 200m

2m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER042 1 - 55 Hz, 0.0031 g/lbf PASS


1 - 163.0 Hz, 0.0145 g/lbf 2 - 70 Hz, 0.0057 g/lbf
2 - 145.0 Hz, 0.0138 g/lbf 3 - 110 Hz, 0.0024 g/lbf
3 - 155.0 Hz, 0.0122 g/lbf 4 - 140 Hz, 0.0112 g/lbf
20m 500m

1 400m
15m 2
3
300m
Amplitude g/lbf

Amplitude g/lbf

10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET042 1 - 55 Hz, 0.0005 g/lbf PASS


1 - 155.0 Hz, 0.0081 g/lbf 2 - 70 Hz, 0.0015 g/lbf
2 - 186.5 Hz, 0.0076 g/lbf 3 - 110 Hz, 0.0019 g/lbf
3 - 152.5 Hz, 0.0075 g/lbf 4 - 140 Hz, 0.0031 g/lbf
10m 500m

1
8m 3 2 400m

6m 300m
Amplitude g/lbf

Amplitude g/lbf

4m 200m

2m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1085 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA043 1 - 55 Hz, 0.0008 g/lbf PASS


1 - 189.0 Hz, 0.0085 g/lbf 2 - 70 Hz, 0.0014 g/lbf
2 - 131.5 Hz, 0.0082 g/lbf 3 - 110 Hz, 0.0028 g/lbf
3 - 192.0 Hz, 0.0080 g/lbf 4 - 140 Hz, 0.0016 g/lbf
10m 500m
2 1
3
8m 400m

6m 300m
Amplitude g/lbf

Amplitude g/lbf
4m 200m

2m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER043 1 - 55 Hz, 0.0030 g/lbf PASS


1 - 163.0 Hz, 0.0168 g/lbf 2 - 70 Hz, 0.0065 g/lbf
2 - 145.0 Hz, 0.0152 g/lbf 3 - 110 Hz, 0.0028 g/lbf
3 - 155.5 Hz, 0.0148 g/lbf 4 - 140 Hz, 0.0120 g/lbf
20m 500m
1
2 3 400m
15m

300m
Amplitude g/lbf

Amplitude g/lbf

10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET043 1 - 55 Hz, 0.0011 g/lbf PASS


1 - 118.5 Hz, 0.0037 g/lbf 2 - 70 Hz, 0.0019 g/lbf
2 - 124.0 Hz, 0.0036 g/lbf 3 - 110 Hz, 0.0017 g/lbf
3 - 169.0 Hz, 0.0036 g/lbf 4 - 140 Hz, 0.0014 g/lbf
5m 500m

4m 12 400m
3

3m 300m
Amplitude g/lbf

Amplitude g/lbf

2m 200m

1m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1086 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA044 1 - 55 Hz, 0.0007 g/lbf PASS


1 - 131.5 Hz, 0.0085 g/lbf 2 - 70 Hz, 0.0011 g/lbf
2 - 177.5 Hz, 0.0077 g/lbf 3 - 110 Hz, 0.0026 g/lbf
3 - 192.0 Hz, 0.0075 g/lbf 4 - 140 Hz, 0.0018 g/lbf
10m 500m
1
8m 2 3 400m

6m 300m
Amplitude g/lbf

Amplitude g/lbf
4m 200m

2m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER044 1 - 55 Hz, 0.0028 g/lbf PASS


1 - 163.0 Hz, 0.0189 g/lbf 2 - 70 Hz, 0.0068 g/lbf
2 - 159.0 Hz, 0.0171 g/lbf 3 - 110 Hz, 0.0033 g/lbf
3 - 145.0 Hz, 0.0166 g/lbf 4 - 140 Hz, 0.0123 g/lbf
20m 1 500m
3 2
400m
15m

300m
Amplitude g/lbf

Amplitude g/lbf

10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET044 1 - 55 Hz, 0.0004 g/lbf PASS


1 - 199.5 Hz, 0.0066 g/lbf 2 - 70 Hz, 0.0019 g/lbf
2 - 152.5 Hz, 0.0063 g/lbf 3 - 110 Hz, 0.0014 g/lbf
3 - 154.5 Hz, 0.0060 g/lbf 4 - 140 Hz, 0.0016 g/lbf
8m 500m

2
3 400m
6m

300m
Amplitude g/lbf

Amplitude g/lbf

4m
200m

2m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1087 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA045 1 - 55 Hz, 0.0007 g/lbf PASS


1 - 132.0 Hz, 0.0090 g/lbf 2 - 70 Hz, 0.0009 g/lbf
2 - 178.0 Hz, 0.0076 g/lbf 3 - 110 Hz, 0.0024 g/lbf
3 - 134.0 Hz, 0.0068 g/lbf 4 - 140 Hz, 0.0025 g/lbf
10m 500m
1

8m 2 400m
3

6m 300m
Amplitude g/lbf

Amplitude g/lbf
4m 200m

2m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER045 1 - 55 Hz, 0.0027 g/lbf PASS


1 - 159.0 Hz, 0.0189 g/lbf 2 - 70 Hz, 0.0069 g/lbf
2 - 163.0 Hz, 0.0180 g/lbf 3 - 110 Hz, 0.0036 g/lbf
3 - 155.5 Hz, 0.0163 g/lbf 4 - 140 Hz, 0.0110 g/lbf
20m 1 500m
2
3
400m
15m

300m
Amplitude g/lbf

Amplitude g/lbf

10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET045 1 - 55 Hz, 0.0003 g/lbf PASS


1 - 199.0 Hz, 0.0065 g/lbf 2 - 70 Hz, 0.0021 g/lbf
2 - 152.5 Hz, 0.0063 g/lbf 3 - 110 Hz, 0.0012 g/lbf
3 - 164.0 Hz, 0.0062 g/lbf 4 - 140 Hz, 0.0014 g/lbf
8m 500m

2 3
400m
6m

300m
Amplitude g/lbf

Amplitude g/lbf

4m
200m

2m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1088 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA046 1 - 55 Hz, 0.0010 g/lbf PASS


1 - 132.0 Hz, 0.0100 g/lbf 2 - 70 Hz, 0.0013 g/lbf
2 - 178.5 Hz, 0.0079 g/lbf 3 - 110 Hz, 0.0027 g/lbf
3 - 134.0 Hz, 0.0075 g/lbf 4 - 140 Hz, 0.0040 g/lbf
10m 500m

2
8m 3 400m

6m 300m
Amplitude g/lbf

Amplitude g/lbf
4m 200m

2m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER046 1 - 55 Hz, 0.0025 g/lbf PASS


1 - 159.0 Hz, 0.0168 g/lbf 2 - 70 Hz, 0.0069 g/lbf
2 - 163.0 Hz, 0.0142 g/lbf 3 - 110 Hz, 0.0037 g/lbf
3 - 155.5 Hz, 0.0138 g/lbf 4 - 140 Hz, 0.0084 g/lbf
20m 500m
1
400m
15m 3 2

300m
Amplitude g/lbf

Amplitude g/lbf

10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET046 1 - 55 Hz, 0.0005 g/lbf PASS


1 - 199.5 Hz, 0.0080 g/lbf 2 - 70 Hz, 0.0017 g/lbf
2 - 164.0 Hz, 0.0076 g/lbf 3 - 110 Hz, 0.0019 g/lbf
3 - 168.0 Hz, 0.0073 g/lbf 4 - 140 Hz, 0.0024 g/lbf
10m 500m

8m 2 400m
3

6m 300m
Amplitude g/lbf

Amplitude g/lbf

4m 200m

2m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1089 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA047 1 - 55 Hz, 0.0010 g/lbf PASS


1 - 132.0 Hz, 0.0110 g/lbf 2 - 70 Hz, 0.0013 g/lbf
2 - 145.5 Hz, 0.0087 g/lbf 3 - 110 Hz, 0.0031 g/lbf
3 - 179.0 Hz, 0.0084 g/lbf 4 - 140 Hz, 0.0053 g/lbf
200m 500m

400m

300m
Amplitude g/lbf

Amplitude g/lbf
100m
200m

100m
1 2 3
1 2 3
0 0
0 50 100 150 200 50 60 80 100 120 140
Frequency - Hz Frequency - Hz

CER047 1 - 55 Hz, 0.0026 g/lbf PASS


1 - 159.0 Hz, 0.0154 g/lbf 2 - 70 Hz, 0.0073 g/lbf
2 - 155.0 Hz, 0.0121 g/lbf 3 - 110 Hz, 0.0041 g/lbf
3 - 163.0 Hz, 0.0113 g/lbf 4 - 140 Hz, 0.0065 g/lbf
20m 500m

1 400m
15m
2
3 300m
Amplitude g/lbf

Amplitude g/lbf

10m
200m

5m
100m

1 2 3 4
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET047 1 - 55 Hz, 0.0019 g/lbf PASS


1 - 146.0 Hz, 0.0132 g/lbf 2 - 70 Hz, 0.0040 g/lbf
2 - 170.5 Hz, 0.0100 g/lbf 3 - 110 Hz, 0.0050 g/lbf
3 - 123.5 Hz, 0.0096 g/lbf 4 - 140 Hz, 0.0058 g/lbf
20m 500m

400m
15m
1
300m
Amplitude g/lbf

Amplitude g/lbf

3 2
10m
200m

5m
100m

1 2 3 4
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1090 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA048 1 - 55 Hz, 0.0012 g/lbf PASS


1 - 132.0 Hz, 0.0115 g/lbf 2 - 70 Hz, 0.0016 g/lbf
2 - 145.5 Hz, 0.0112 g/lbf 3 - 110 Hz, 0.0037 g/lbf
3 - 179.0 Hz, 0.0107 g/lbf 4 - 140 Hz, 0.0068 g/lbf
20m 500m

400m
15m

1 2 300m
3
Amplitude g/lbf

Amplitude g/lbf
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER048 1 - 55 Hz, 0.0027 g/lbf PASS


1 - 128.5 Hz, 0.0128 g/lbf 2 - 70 Hz, 0.0078 g/lbf
2 - 159.0 Hz, 0.0128 g/lbf 3 - 110 Hz, 0.0054 g/lbf
3 - 198.5 Hz, 0.0110 g/lbf 4 - 140 Hz, 0.0061 g/lbf
40m 500m

400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf

20m

1 2 200m

10m
100m

1 2 3 4
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET048 1 - 55 Hz, 0.0023 g/lbf PASS


1 - 146.0 Hz, 0.0127 g/lbf 2 - 70 Hz, 0.0051 g/lbf
2 - 126.0 Hz, 0.0121 g/lbf 3 - 110 Hz, 0.0066 g/lbf
3 - 123.5 Hz, 0.0115 g/lbf 4 - 140 Hz, 0.0057 g/lbf
20m 500m

400m
15m
2 1
3 300m
Amplitude g/lbf

Amplitude g/lbf

10m
200m

5m
100m

1 2 3 4
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1091 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA052 1 - 55 Hz, 0.0013 g/lbf PASS


1 - 145.5 Hz, 0.0141 g/lbf 2 - 70 Hz, 0.0010 g/lbf
2 - 129.0 Hz, 0.0083 g/lbf 3 - 110 Hz, 0.0028 g/lbf
3 - 140.0 Hz, 0.0068 g/lbf 4 - 140 Hz, 0.0068 g/lbf
20m 500m

400m
15m 1

300m
Amplitude g/lbf

Amplitude g/lbf
10m
2
3 200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER052 1 - 55 Hz, 0.0037 g/lbf PASS


1 - 169.0 Hz, 0.0228 g/lbf 2 - 70 Hz, 0.0019 g/lbf
2 - 153.0 Hz, 0.0181 g/lbf 3 - 110 Hz, 0.0030 g/lbf
3 - 162.0 Hz, 0.0160 g/lbf 4 - 140 Hz, 0.0098 g/lbf
40m 500m

400m
30m

1 300m
Amplitude g/lbf

Amplitude g/lbf

20m 2
3
200m

10m
100m

1 2 3 4
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET052 1 - 55 Hz, 0.0017 g/lbf PASS


1 - 169.0 Hz, 0.0228 g/lbf 2 - 70 Hz, 0.0044 g/lbf
2 - 170.0 Hz, 0.0216 g/lbf 3 - 110 Hz, 0.0030 g/lbf
3 - 175.0 Hz, 0.0133 g/lbf 4 - 140 Hz, 0.0058 g/lbf
40m 500m

400m
30m

1 300m
2
Amplitude g/lbf

Amplitude g/lbf

20m

3 200m

10m
100m

1 2 3 4
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1092 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA053 1 - 55 Hz, 0.0012 g/lbf PASS


1 - 145.5 Hz, 0.0117 g/lbf 2 - 70 Hz, 0.0010 g/lbf
2 - 129.0 Hz, 0.0060 g/lbf 3 - 110 Hz, 0.0023 g/lbf
3 - 140.0 Hz, 0.0056 g/lbf 4 - 140 Hz, 0.0056 g/lbf
20m 500m

400m
15m
1 300m
Amplitude g/lbf

Amplitude g/lbf
10m
200m
2 3
5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER053 1 - 55 Hz, 0.0033 g/lbf PASS


1 - 169.0 Hz, 0.0230 g/lbf 2 - 70 Hz, 0.0017 g/lbf
2 - 153.0 Hz, 0.0173 g/lbf 3 - 110 Hz, 0.0024 g/lbf
3 - 162.5 Hz, 0.0151 g/lbf 4 - 140 Hz, 0.0083 g/lbf
50m 500m

40m 400m

30m 300m
Amplitude g/lbf

Amplitude g/lbf

1
20m 2 200m
3

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET053 1 - 55 Hz, 0.0004 g/lbf PASS


1 - 169.0 Hz, 0.0070 g/lbf 2 - 70 Hz, 0.0025 g/lbf
2 - 171.0 Hz, 0.0067 g/lbf 3 - 110 Hz, 0.0002 g/lbf
3 - 175.0 Hz, 0.0041 g/lbf 4 - 140 Hz, 0.0005 g/lbf
8m 500m
12
400m
6m

300m
Amplitude g/lbf

Amplitude g/lbf

3
4m
200m

2m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1093 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA054 1 - 55 Hz, 0.0012 g/lbf PASS


1 - 145.5 Hz, 0.0089 g/lbf 2 - 70 Hz, 0.0011 g/lbf
2 - 142.5 Hz, 0.0056 g/lbf 3 - 110 Hz, 0.0025 g/lbf
3 - 129.0 Hz, 0.0055 g/lbf 4 - 140 Hz, 0.0047 g/lbf
10m 500m
1

8m 400m

6m 3 2 300m
Amplitude g/lbf

Amplitude g/lbf
4m 200m

2m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER054 1 - 55 Hz, 0.0032 g/lbf PASS


1 - 169.0 Hz, 0.0228 g/lbf 2 - 70 Hz, 0.0018 g/lbf
2 - 153.5 Hz, 0.0170 g/lbf 3 - 110 Hz, 0.0025 g/lbf
3 - 162.5 Hz, 0.0152 g/lbf 4 - 140 Hz, 0.0071 g/lbf
40m 500m

400m
30m

1 300m
Amplitude g/lbf

Amplitude g/lbf

20m 2
3 200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET054 1 - 55 Hz, 0.0012 g/lbf PASS


1 - 146.0 Hz, 0.0074 g/lbf 2 - 70 Hz, 0.0014 g/lbf
2 - 148.5 Hz, 0.0056 g/lbf 3 - 110 Hz, 0.0013 g/lbf
3 - 66.0 Hz, 0.0056 g/lbf 4 - 140 Hz, 0.0032 g/lbf
8m 1 500m

400m
6m 3 2

300m
Amplitude g/lbf

Amplitude g/lbf

4m
200m

2m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1094 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA055 1 - 55 Hz, 0.0012 g/lbf PASS


1 - 186.5 Hz, 0.0074 g/lbf 2 - 70 Hz, 0.0014 g/lbf
2 - 194.5 Hz, 0.0062 g/lbf 3 - 110 Hz, 0.0031 g/lbf
3 - 145.5 Hz, 0.0060 g/lbf 4 - 140 Hz, 0.0039 g/lbf
8m 1 500m

3 2 400m
6m

300m
Amplitude g/lbf

Amplitude g/lbf
4m
200m

2m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER055 1 - 55 Hz, 0.0037 g/lbf PASS


1 - 169.5 Hz, 0.0222 g/lbf 2 - 70 Hz, 0.0025 g/lbf
2 - 153.5 Hz, 0.0182 g/lbf 3 - 110 Hz, 0.0035 g/lbf
3 - 162.5 Hz, 0.0165 g/lbf 4 - 140 Hz, 0.0055 g/lbf
40m 500m

400m
30m

1 300m
Amplitude g/lbf

Amplitude g/lbf

20m 2
3
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET055 1 - 55 Hz, 0.0005 g/lbf PASS


1 - 171.0 Hz, 0.0098 g/lbf 2 - 70 Hz, 0.0037 g/lbf
2 - 198.0 Hz, 0.0089 g/lbf 3 - 110 Hz, 0.0021 g/lbf
3 - 167.5 Hz, 0.0080 g/lbf 1 4 - 140 Hz, 0.0014 g/lbf
10m 500m
2
3
8m 400m

6m 300m
Amplitude g/lbf

Amplitude g/lbf

4m 200m

2m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1095 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA056 1 - 55 Hz, 0.0010 g/lbf PASS


1 - 187.0 Hz, 0.0084 g/lbf 2 - 70 Hz, 0.0016 g/lbf
2 - 195.0 Hz, 0.0083 g/lbf 3 - 110 Hz, 0.0031 g/lbf
3 - 133.5 Hz, 0.0080 g/lbf 4 - 140 Hz, 0.0028 g/lbf
10m 500m
1 2
3
8m 400m

6m 300m
Amplitude g/lbf

Amplitude g/lbf
4m 200m

2m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER056 1 - 55 Hz, 0.0038 g/lbf PASS


1 - 170.0 Hz, 0.0176 g/lbf 2 - 70 Hz, 0.0030 g/lbf
2 - 153.5 Hz, 0.0170 g/lbf 3 - 110 Hz, 0.0041 g/lbf
3 - 163.0 Hz, 0.0158 g/lbf 4 - 140 Hz, 0.0031 g/lbf
20m 500m
2 1
3
400m
15m

300m
Amplitude g/lbf

Amplitude g/lbf

10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET056 1 - 55 Hz, 0.0004 g/lbf PASS


1 - 171.0 Hz, 0.0094 g/lbf 2 - 70 Hz, 0.0039 g/lbf
2 - 167.5 Hz, 0.0081 g/lbf 3 - 110 Hz, 0.0020 g/lbf
3 - 164.5 Hz, 0.0069 g/lbf 4 - 140 Hz, 0.0030 g/lbf
20m 500m

400m
15m

300m
Amplitude g/lbf

Amplitude g/lbf

10m 1
2
3 200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1096 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA057 1 - 55 Hz, 0.0009 g/lbf PASS


1 - 196.0 Hz, 0.0113 g/lbf 2 - 70 Hz, 0.0017 g/lbf
2 - 195.0 Hz, 0.0113 g/lbf 3 - 110 Hz, 0.0036 g/lbf
3 - 133.5 Hz, 0.0103 g/lbf 4 - 140 Hz, 0.0023 g/lbf
20m 500m

400m
15m

21 300m
Amplitude g/lbf

Amplitude g/lbf
3
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER057 1 - 55 Hz, 0.0040 g/lbf PASS


1 - 157.5 Hz, 0.0147 g/lbf 2 - 70 Hz, 0.0038 g/lbf
2 - 90.5 Hz, 0.0142 g/lbf 3 - 110 Hz, 0.0055 g/lbf
3 - 153.5 Hz, 0.0138 g/lbf 4 - 140 Hz, 0.0013 g/lbf
40m 500m

400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf

20m
2 31 200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET057 1 - 55 Hz, 0.0008 g/lbf PASS


1 - 197.5 Hz, 0.0136 g/lbf 2 - 70 Hz, 0.0030 g/lbf
2 - 134.0 Hz, 0.0133 g/lbf 3 - 110 Hz, 0.0033 g/lbf
3 - 122.0 Hz, 0.0093 g/lbf 4 - 140 Hz, 0.0028 g/lbf
20m 500m

400m
15m
2
300m
Amplitude g/lbf

Amplitude g/lbf

10m 3
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1097 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA058 1 - 55 Hz, 0.0013 g/lbf PASS


1 - 196.0 Hz, 0.0120 g/lbf 2 - 70 Hz, 0.0022 g/lbf
2 - 195.0 Hz, 0.0120 g/lbf 3 - 110 Hz, 0.0043 g/lbf
3 - 134.0 Hz, 0.0103 g/lbf 4 - 140 Hz, 0.0021 g/lbf
20m 500m

400m
15m
21
300m
Amplitude g/lbf

Amplitude g/lbf
3
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER058 1 - 55 Hz, 0.0042 g/lbf PASS


1 - 126.0 Hz, 0.0161 g/lbf 2 - 70 Hz, 0.0047 g/lbf
2 - 123.5 Hz, 0.0148 g/lbf 3 - 110 Hz, 0.0076 g/lbf
3 - 90.5 Hz, 0.0141 g/lbf 4 - 140 Hz, 0.0033 g/lbf
20m 500m

1
2 400m
15m 3

300m
Amplitude g/lbf

Amplitude g/lbf

10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET058 1 - 55 Hz, 0.0015 g/lbf PASS


1 - 134.0 Hz, 0.0171 g/lbf 2 - 70 Hz, 0.0029 g/lbf
2 - 197.5 Hz, 0.0127 g/lbf 3 - 110 Hz, 0.0044 g/lbf
3 - 130.0 Hz, 0.0114 g/lbf 4 - 140 Hz, 0.0049 g/lbf
20m 500m
1
400m
15m
2
3 300m
Amplitude g/lbf

Amplitude g/lbf

10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1098 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA059 1 - 55 Hz, 0.0012 g/lbf PASS


1 - 133.5 Hz, 0.0145 g/lbf 2 - 70 Hz, 0.0024 g/lbf
2 - 196.5 Hz, 0.0133 g/lbf 3 - 110 Hz, 0.0052 g/lbf
3 - 122.0 Hz, 0.0117 g/lbf 4 - 140 Hz, 0.0035 g/lbf
20m 500m

1 400m
15m
2
3
300m
Amplitude g/lbf

Amplitude g/lbf
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER059 1 - 55 Hz, 0.0038 g/lbf PASS


1 - 126.0 Hz, 0.0206 g/lbf 2 - 70 Hz, 0.0054 g/lbf
2 - 123.5 Hz, 0.0192 g/lbf 3 - 110 Hz, 0.0088 g/lbf
3 - 111.5 Hz, 0.0138 g/lbf 4 - 140 Hz, 0.0048 g/lbf
40m 500m

400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf

1
20m 2

3 200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET059 1 - 55 Hz, 0.0002 g/lbf PASS


1 - 128.5 Hz, 0.0062 g/lbf 2 - 70 Hz, 0.0013 g/lbf
2 - 126.5 Hz, 0.0055 g/lbf 3 - 110 Hz, 0.0006 g/lbf
3 - 133.0 Hz, 0.0046 g/lbf 4 - 140 Hz, 0.0032 g/lbf
8m 500m

1 400m
6m 2
3 300m
Amplitude g/lbf

Amplitude g/lbf

4m
200m

2m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1099 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA060 1 - 55 Hz, 0.0014 g/lbf PASS


1 - 133.5 Hz, 0.0182 g/lbf 2 - 70 Hz, 0.0027 g/lbf
2 - 121.5 Hz, 0.0154 g/lbf 3 - 110 Hz, 0.0067 g/lbf
3 - 196.5 Hz, 0.0147 g/lbf 4 - 140 Hz, 0.0043 g/lbf
20m 1 500m

2 400m
3
15m

300m
Amplitude g/lbf

Amplitude g/lbf
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER060 1 - 55 Hz, 0.0038 g/lbf PASS


1 - 123.5 Hz, 0.0290 g/lbf 2 - 70 Hz, 0.0062 g/lbf
2 - 125.5 Hz, 0.0281 g/lbf 3 - 110 Hz, 0.0132 g/lbf
3 - 169.0 Hz, 0.0178 g/lbf 4 - 140 Hz, 0.0080 g/lbf
40m 500m

12 400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf

20m 3
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET060 1 - 55 Hz, 0.0027 g/lbf PASS


1 - 185.5 Hz, 0.0204 g/lbf 2 - 70 Hz, 0.0014 g/lbf
2 - 133.0 Hz, 0.0200 g/lbf 3 - 110 Hz, 0.0045 g/lbf
3 - 189.5 Hz, 0.0181 g/lbf 4 - 140 Hz, 0.0094 g/lbf
40m 500m

400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf

2 1
20m 3
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1100 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA064 1 - 55 Hz, 0.0017 g/lbf PASS


1 - 194.5 Hz, 0.0198 g/lbf 2 - 70 Hz, 0.0033 g/lbf
2 - 189.5 Hz, 0.0180 g/lbf 3 - 110 Hz, 0.0052 g/lbf
3 - 171.0 Hz, 0.0125 g/lbf 4 - 140 Hz, 0.0051 g/lbf
40m 500m

400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf
1
20m 2
200m
3
10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER064 1 - 55 Hz, 0.0050 g/lbf PASS


1 - 196.5 Hz, 0.0550 g/lbf 2 - 70 Hz, 0.0166 g/lbf
2 - 195.0 Hz, 0.0545 g/lbf 3 - 110 Hz, 0.0079 g/lbf
3 - 182.5 Hz, 0.0524 g/lbf 4 - 140 Hz, 0.0039 g/lbf
80m 500m

400m
60m 21
3
300m
Amplitude g/lbf

Amplitude g/lbf

40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET064 1 - 55 Hz, 0.0016 g/lbf PASS


1 - 189.0 Hz, 0.0191 g/lbf 2 - 70 Hz, 0.0027 g/lbf
2 - 170.5 Hz, 0.0167 g/lbf 3 - 110 Hz, 0.0039 g/lbf
3 - 193.0 Hz, 0.0167 g/lbf 4 - 140 Hz, 0.0094 g/lbf
40m 500m

400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf

20m 1
2 3
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1101 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA065 1 - 55 Hz, 0.0015 g/lbf PASS


1 - 194.5 Hz, 0.0133 g/lbf 2 - 70 Hz, 0.0034 g/lbf
2 - 196.5 Hz, 0.0125 g/lbf 3 - 110 Hz, 0.0029 g/lbf
3 - 189.5 Hz, 0.0123 g/lbf 4 - 140 Hz, 0.0028 g/lbf
20m 500m

400m
15m
1
32
300m
Amplitude g/lbf

Amplitude g/lbf
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER065 1 - 55 Hz, 0.0050 g/lbf PASS


1 - 196.5 Hz, 0.0426 g/lbf 2 - 70 Hz, 0.0182 g/lbf
2 - 195.0 Hz, 0.0422 g/lbf 3 - 110 Hz, 0.0066 g/lbf
3 - 182.5 Hz, 0.0375 g/lbf 4 - 140 Hz, 0.0055 g/lbf
50m 500m
21
40m 3 400m

30m 300m
Amplitude g/lbf

Amplitude g/lbf

20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET065 1 - 55 Hz, 0.0018 g/lbf PASS


1 - 195.0 Hz, 0.0217 g/lbf 2 - 70 Hz, 0.0015 g/lbf
2 - 189.0 Hz, 0.0181 g/lbf 3 - 110 Hz, 0.0057 g/lbf
3 - 171.0 Hz, 0.0147 g/lbf 4 - 140 Hz, 0.0051 g/lbf
40m 500m

400m
30m

1 300m
Amplitude g/lbf

Amplitude g/lbf

20m 2
3 200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1102 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA066 1 - 55 Hz, 0.0012 g/lbf PASS


1 - 194.5 Hz, 0.0130 g/lbf 2 - 70 Hz, 0.0025 g/lbf
2 - 190.0 Hz, 0.0105 g/lbf 3 - 110 Hz, 0.0023 g/lbf
3 - 129.5 Hz, 0.0073 g/lbf 4 - 140 Hz, 0.0024 g/lbf
20m 500m

400m
15m
1
300m
Amplitude g/lbf

Amplitude g/lbf
2
10m
3 200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER066 1 - 55 Hz, 0.0045 g/lbf PASS


1 - 197.0 Hz, 0.0262 g/lbf 2 - 70 Hz, 0.0189 g/lbf
2 - 69.5 Hz, 0.0220 g/lbf 3 - 110 Hz, 0.0056 g/lbf
3 - 183.0 Hz, 0.0200 g/lbf 4 - 140 Hz, 0.0081 g/lbf
40m 500m

400m
30m
1
2 300m
Amplitude g/lbf

Amplitude g/lbf

3
20m
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET066 1 - 55 Hz, 0.0001 g/lbf PASS


1 - 188.0 Hz, 0.0120 g/lbf 2 - 70 Hz, 0.0053 g/lbf
2 - 193.0 Hz, 0.0117 g/lbf 3 - 110 Hz, 0.0025 g/lbf
3 - 170.5 Hz, 0.0099 g/lbf 4 - 140 Hz, 0.0066 g/lbf
20m 500m

400m
15m
12
300m
Amplitude g/lbf

Amplitude g/lbf

3
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1103 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA067 1 - 55 Hz, 0.0010 g/lbf PASS


1 - 194.5 Hz, 0.0156 g/lbf 2 - 70 Hz, 0.0012 g/lbf
2 - 196.5 Hz, 0.0135 g/lbf 3 - 110 Hz, 0.0028 g/lbf
3 - 190.0 Hz, 0.0112 g/lbf 4 - 140 Hz, 0.0029 g/lbf
20m 500m

1 400m
15m 2
3 300m
Amplitude g/lbf

Amplitude g/lbf
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER067 1 - 55 Hz, 0.0046 g/lbf PASS


1 - 69.5 Hz, 0.0231 g/lbf 2 - 70 Hz, 0.0195 g/lbf
2 - 134.5 Hz, 0.0187 g/lbf 3 - 110 Hz, 0.0057 g/lbf
3 - 96.5 Hz, 0.0167 g/lbf 4 - 140 Hz, 0.0095 g/lbf
40m 500m

400m
30m
1 300m
Amplitude g/lbf

Amplitude g/lbf

20m 2
3
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET067 1 - 55 Hz, 0.0025 g/lbf PASS


1 - 127.5 Hz, 0.0105 g/lbf 2 - 70 Hz, 0.0079 g/lbf
2 - 185.5 Hz, 0.0091 g/lbf 3 - 110 Hz, 0.0050 g/lbf
3 - 68.5 Hz, 0.0091 g/lbf 4 - 140 Hz, 0.0027 g/lbf
20m 500m

400m
15m

300m
Amplitude g/lbf

Amplitude g/lbf

1
10m 3 2
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1104 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA068 1 - 55 Hz, 0.0010 g/lbf PASS


1 - 194.5 Hz, 0.0166 g/lbf 2 - 70 Hz, 0.0008 g/lbf
2 - 196.5 Hz, 0.0151 g/lbf 3 - 110 Hz, 0.0027 g/lbf
3 - 129.0 Hz, 0.0094 g/lbf 4 - 140 Hz, 0.0029 g/lbf
20m 500m
1
2 400m
15m

300m
Amplitude g/lbf

Amplitude g/lbf
10m 3
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER068 1 - 55 Hz, 0.0047 g/lbf PASS


1 - 69.5 Hz, 0.0228 g/lbf 2 - 70 Hz, 0.0191 g/lbf
2 - 96.5 Hz, 0.0174 g/lbf 3 - 110 Hz, 0.0055 g/lbf
3 - 134.5 Hz, 0.0159 g/lbf 4 - 140 Hz, 0.0093 g/lbf
40m 500m

400m
30m

1 300m
Amplitude g/lbf

Amplitude g/lbf

20m 2
3
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET068 1 - 55 Hz, 0.0014 g/lbf PASS


1 - 134.5 Hz, 0.0106 g/lbf 2 - 70 Hz, 0.0097 g/lbf
2 - 69.5 Hz, 0.0105 g/lbf 3 - 110 Hz, 0.0030 g/lbf
3 - 68.5 Hz, 0.0101 g/lbf 4 - 140 Hz, 0.0066 g/lbf
20m 500m

400m
15m

300m
Amplitude g/lbf

Amplitude g/lbf

32 1
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1105 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA069 1 - 55 Hz, 0.0011 g/lbf PASS


1 - 194.5 Hz, 0.0192 g/lbf 2 - 70 Hz, 0.0008 g/lbf
2 - 196.5 Hz, 0.0181 g/lbf 3 - 110 Hz, 0.0041 g/lbf
3 - 129.0 Hz, 0.0117 g/lbf 4 - 140 Hz, 0.0042 g/lbf
20m 1 500m
2

400m
15m
3
300m
Amplitude g/lbf

Amplitude g/lbf
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER069 1 - 55 Hz, 0.0049 g/lbf PASS


1 - 69.5 Hz, 0.0220 g/lbf 2 - 70 Hz, 0.0180 g/lbf
2 - 96.0 Hz, 0.0171 g/lbf 3 - 110 Hz, 0.0052 g/lbf
3 - 94.0 Hz, 0.0146 g/lbf 4 - 140 Hz, 0.0080 g/lbf
40m 500m

400m
30m

1 300m
Amplitude g/lbf

Amplitude g/lbf

20m 2
3 200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET069 1 - 55 Hz, 0.0003 g/lbf PASS


1 - 195.5 Hz, 0.0123 g/lbf 2 - 70 Hz, 0.0079 g/lbf
2 - 183.5 Hz, 0.0112 g/lbf 3 - 110 Hz, 0.0043 g/lbf
3 - 179.5 Hz, 0.0093 g/lbf 4 - 140 Hz, 0.0062 g/lbf
20m 500m

400m
15m
1
2 300m
Amplitude g/lbf

Amplitude g/lbf

10m 3
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1106 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA070 1 - 55 Hz, 0.0014 g/lbf PASS


1 - 194.5 Hz, 0.0139 g/lbf 2 - 70 Hz, 0.0009 g/lbf
2 - 129.0 Hz, 0.0101 g/lbf 3 - 110 Hz, 0.0038 g/lbf
3 - 145.0 Hz, 0.0093 g/lbf 4 - 140 Hz, 0.0040 g/lbf
20m 500m

400m
15m 1

300m
Amplitude g/lbf

Amplitude g/lbf
2
10m 3
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER070 1 - 55 Hz, 0.0048 g/lbf PASS


1 - 69.5 Hz, 0.0201 g/lbf 2 - 70 Hz, 0.0164 g/lbf
2 - 182.5 Hz, 0.0183 g/lbf 3 - 110 Hz, 0.0042 g/lbf
3 - 177.5 Hz, 0.0179 g/lbf 4 - 140 Hz, 0.0055 g/lbf
40m 500m

400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf

1
20m 32
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET070 1 - 55 Hz, 0.0001 g/lbf PASS


1 - 183.5 Hz, 0.0087 g/lbf 2 - 70 Hz, 0.0045 g/lbf
2 - 191.5 Hz, 0.0065 g/lbf 3 - 110 Hz, 0.0022 g/lbf
3 - 190.0 Hz, 0.0065 g/lbf 4 - 140 Hz, 0.0007 g/lbf
10m 500m
1
8m 400m
32
6m 300m
Amplitude g/lbf

Amplitude g/lbf

4m 200m

2m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1107 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA071 1 - 55 Hz, 0.0012 g/lbf PASS


1 - 134.5 Hz, 0.0113 g/lbf 2 - 70 Hz, 0.0008 g/lbf
2 - 129.0 Hz, 0.0104 g/lbf 3 - 110 Hz, 0.0043 g/lbf
3 - 145.0 Hz, 0.0103 g/lbf 4 - 140 Hz, 0.0035 g/lbf
20m 500m

400m
15m

1 300m
Amplitude g/lbf

Amplitude g/lbf
2 3
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER071 1 - 55 Hz, 0.0048 g/lbf PASS


1 - 182.5 Hz, 0.0267 g/lbf 2 - 70 Hz, 0.0144 g/lbf
2 - 177.5 Hz, 0.0262 g/lbf 3 - 110 Hz, 0.0045 g/lbf
3 - 197.0 Hz, 0.0250 g/lbf 4 - 140 Hz, 0.0060 g/lbf
40m 500m

400m
30m
21 3
300m
Amplitude g/lbf

Amplitude g/lbf

20m
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET071 1 - 55 Hz, 0.0006 g/lbf PASS


1 - 183.0 Hz, 0.0109 g/lbf 2 - 70 Hz, 0.0060 g/lbf
2 - 178.0 Hz, 0.0092 g/lbf 3 - 110 Hz, 0.0016 g/lbf
3 - 198.0 Hz, 0.0070 g/lbf 4 - 140 Hz, 0.0010 g/lbf
20m 500m

400m
15m

1 300m
Amplitude g/lbf

Amplitude g/lbf

10m 2
3 200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1108 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA072 1 - 55 Hz, 0.0013 g/lbf PASS


1 - 134.5 Hz, 0.0131 g/lbf 2 - 70 Hz, 0.0013 g/lbf
2 - 145.0 Hz, 0.0109 g/lbf 3 - 110 Hz, 0.0054 g/lbf
3 - 129.5 Hz, 0.0106 g/lbf 4 - 140 Hz, 0.0040 g/lbf
20m 500m

400m
15m
1
3 2 300m
Amplitude g/lbf

Amplitude g/lbf
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER072 1 - 55 Hz, 0.0047 g/lbf PASS


1 - 177.5 Hz, 0.0323 g/lbf 2 - 70 Hz, 0.0124 g/lbf
2 - 182.5 Hz, 0.0315 g/lbf 3 - 110 Hz, 0.0056 g/lbf
3 - 197.0 Hz, 0.0263 g/lbf 4 - 140 Hz, 0.0059 g/lbf
40m 500m

12
400m
30m
3
300m
Amplitude g/lbf

Amplitude g/lbf

20m
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET072 1 - 55 Hz, 0.0002 g/lbf PASS


1 - 183.0 Hz, 0.0126 g/lbf 2 - 70 Hz, 0.0017 g/lbf
2 - 178.0 Hz, 0.0103 g/lbf 3 - 110 Hz, 0.0018 g/lbf
3 - 198.0 Hz, 0.0093 g/lbf 4 - 140 Hz, 0.0011 g/lbf
20m 500m

400m
15m
1
300m
Amplitude g/lbf

Amplitude g/lbf

2
10m 3
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1109 of 1653


Bump Test_As Found

GE Power Inspection & Life Extension Services


Endwinding Vibration Test Report

Enclosure 3
Collector End Phase Connection Frequency Response
(Amplitude versus Frequency)

GE Proprietary Information. This document contains proprietary information of the General Electric Company and
may not be used or disclosed to others, except with the written permission of General Electric Company. 9

Page 1110 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCBA001 1 - 55 Hz, 0.0072 g/lbf PASS


1 - 108.0 Hz, 0.2767 g/lbf 2 - 70 Hz, 0.0166 g/lbf
2 - 110.5 Hz, 0.2765 g/lbf 3 - 110 Hz, 0.2750 g/lbf
3 - 98.0 Hz, 0.1200 g/lbf 4 - 140 Hz, 0.0524 g/lbf
400m 500m

400m
300m 12

300m 3
Amplitude g/lbf

Amplitude g/lbf
200m
200m
3
100m
100m

1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBR001 1 - 55 Hz, 0.0127 g/lbf FAIL


1 - 29.0 Hz, 0.7964 g/lbf 2 - 70 Hz, 0.1069 g/lbf
2 - 117.5 Hz, 0.5895 g/lbf 3 - 110 Hz, 0.2708 g/lbf
3 - 114.0
1 Hz, 0.4735 g/lbf 4 - 140 Hz, 0.0564 g/lbf
800m 500m

2 400m
600m
3
300m 3
Amplitude g/lbf

Amplitude g/lbf

400m
200m

200m 2
100m

1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBT001 1 - 55 Hz, 0.0774 g/lbf FAIL


1 - 62.5 Hz, 0.7212 g/lbf 2 - 70 Hz, 0.1185 g/lbf
2 - 29.0 Hz, 0.3491 g/lbf 3 - 110 Hz, 0.0233 g/lbf
3 - 83.0 Hz, 0.0659 g/lbf 4 - 140 Hz, 0.0398 g/lbf
800m 500m
1

400m
600m

300m
Amplitude g/lbf

Amplitude g/lbf

400m 2
200m
2
200m
100m 1
3
3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1111 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCTA001 1 - 55 Hz, 0.0018 g/lbf PASS


1 - 184.0 Hz, 0.1671 g/lbf 2 - 70 Hz, 0.0043 g/lbf
2 - 187.0 Hz, 0.1667 g/lbf 3 - 110 Hz, 0.0145 g/lbf
3 - 179.5 Hz, 0.1402 g/lbf 4 - 140 Hz, 0.0204 g/lbf
200m 500m
12
400m
3

300m
Amplitude g/lbf

Amplitude g/lbf
100m
200m

100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTR001 1 - 55 Hz, 0.0209 g/lbf PASS


1 - 115.5 Hz, 0.1514 g/lbf 2 - 70 Hz, 0.0622 g/lbf
2 - 78.0 Hz, 0.1294 g/lbf 3 - 110 Hz, 0.0882 g/lbf
3 - 82.0 Hz, 0.0974 g/lbf 4 - 140 Hz, 0.0759 g/lbf
200m 500m

1 400m
2
300m
Amplitude g/lbf

Amplitude g/lbf

3
100m
200m

100m 3
2
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTT001 1 - 55 Hz, 0.0079 g/lbf PASS


1 - 115.5 Hz, 0.2468 g/lbf 2 - 70 Hz, 0.0657 g/lbf
2 - 44.0 Hz, 0.2352 g/lbf 3 - 110 Hz, 0.1356 g/lbf
3 - 112.0 Hz, 0.1871 g/lbf 4 - 140 Hz, 0.0750 g/lbf
400m 500m

400m
300m
1
2
300m
Amplitude g/lbf

Amplitude g/lbf

200m 3
200m
3
100m
100m 2
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1112 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCBA002 1 - 55 Hz, 0.0019 g/lbf PASS


1 - 21.5 Hz, 0.2305 g/lbf 2 - 70 Hz, 0.0022 g/lbf
2 - 143.0 Hz, 0.1346 g/lbf 3 - 110 Hz, 0.0362 g/lbf
3 - 178.5 Hz, 0.1220 g/lbf 4 - 140 Hz, 0.1117 g/lbf
400m 500m

400m
300m

1 300m
Amplitude g/lbf

Amplitude g/lbf
200m
2 200m
3
100m
100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBR002 1 - 55 Hz, 0.1137 g/lbf PASS


1 - 42.0 Hz, 1.0169 g/lbf 2 - 70 Hz, 0.0784 g/lbf
2 - 39.5 Hz, 0.3597 g/lbf 3 - 110 Hz, 0.2105 g/lbf
3 - 114.0 Hz, 0.3073 g/lbf 4 - 140 Hz, 0.0138 g/lbf
2 500m

400m
1.5

300m
Amplitude g/lbf

Amplitude g/lbf

1
1 3
200m

500m 1
2 2
3 100m

0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBT002 1 - 55 Hz, 0.0455 g/lbf PASS


1 - 21.5 Hz, 1.5172 g/lbf 2 - 70 Hz, 0.0354 g/lbf
2 - 178.0 Hz, 0.2987 g/lbf 3 - 110 Hz, 0.1147 g/lbf
3 - 115.0 Hz, 0.2408 g/lbf 4 - 140 Hz, 0.0555 g/lbf
2 500m

1 400m
1.5

300m
Amplitude g/lbf

Amplitude g/lbf

1
200m

500m 3
3 2 100m
1 2

0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1113 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCTA002 1 - 55 Hz, 0.0025 g/lbf PASS


1 - 182.5 Hz, 0.0462 g/lbf 2 - 70 Hz, 0.0046 g/lbf
2 - 177.5 Hz, 0.0392 g/lbf 3 - 110 Hz, 0.0091 g/lbf
3 - 196.5 Hz, 0.0363 g/lbf 4 - 140 Hz, 0.0175 g/lbf
50m 1 500m

40m 2 400m
3

30m 300m
Amplitude g/lbf

Amplitude g/lbf
20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTR002 1 - 55 Hz, 0.1293 g/lbf PASS


1 - 98.0 Hz, 0.3670 g/lbf 2 - 70 Hz, 0.0096 g/lbf
2 - 106.5 Hz, 0.1477 g/lbf 3 - 110 Hz, 0.1039 g/lbf
3 - 104.0 Hz, 0.1453 g/lbf 4 - 140 Hz, 0.0406 g/lbf
400m 1 500m

400m
300m

300m
Amplitude g/lbf

Amplitude g/lbf

200m
32 200m
1
100m 3
100m

2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTT002 1 - 55 Hz, 0.3274 g/lbf PASS


1 - 162.0 Hz, 0.5726 g/lbf 2 - 70 Hz, 0.2012 g/lbf
2 - 56.0 Hz, 0.3814 g/lbf 3 - 110 Hz, 0.1084 g/lbf
3 - 66.5 Hz, 0.3371 g/lbf 4 - 140 Hz, 0.0040 g/lbf
800m 500m

400m
600m 1
1
300m
Amplitude g/lbf

Amplitude g/lbf

400m 2
3 2
200m

200m 3
100m

0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1114 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCBA003 1 - 55 Hz, 0.0074 g/lbf PASS


1 - 152.5 Hz, 0.4540 g/lbf 2 - 70 Hz, 0.0295 g/lbf
2 - 164.5 Hz, 0.2586 g/lbf 3 - 110 Hz, 0.0191 g/lbf
3 - 157.0 Hz, 0.1747 g/lbf 4 - 140 Hz, 0.0772 g/lbf
500m 500m
1

400m 400m

300m 300m
Amplitude g/lbf

Amplitude g/lbf
2

200m 3 200m

100m 100m
2 3
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBR003 1 - 55 Hz, 0.0865 g/lbf FAIL


1 - 70.0 Hz, 0.6021 g/lbf 2 - 70 Hz, 0.6021 g/lbf
2 - 68.5 Hz, 0.5879 g/lbf 3 - 110 Hz, 0.0998 g/lbf
3 - 72.0 Hz, 0.5240 g/lbf 4 - 140 Hz, 0.1425 g/lbf
800m 500m

21 400m
600m
3
300m
Amplitude g/lbf

Amplitude g/lbf

400m
200m

200m 3
100m 1

0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBT003 1 - 55 Hz, 0.1457 g/lbf PASS


1 - 44.5 Hz, 0.9477 g/lbf 2 - 70 Hz, 0.0777 g/lbf
2 - 46.0 Hz, 0.5851 g/lbf 3 - 110 Hz, 0.0525 g/lbf
3 - 41.5 Hz, 0.3904 g/lbf 4 - 140 Hz, 0.0279 g/lbf
1 1 500m

800m 400m

2
600m 300m
Amplitude g/lbf

Amplitude g/lbf

3
400m 200m
1

200m 100m 2
3

0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1115 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCTA003 1 - 55 Hz, 0.0161 g/lbf PASS


1 - 152.0 Hz, 0.5851 g/lbf 2 - 70 Hz, 0.0261 g/lbf
2 - 157.5 Hz, 0.2847 g/lbf 3 - 110 Hz, 0.0236 g/lbf
3 - 147.0 Hz, 0.2656 g/lbf 4 - 140 Hz, 0.1821 g/lbf
800m 500m

1 400m
600m

300m
Amplitude g/lbf

Amplitude g/lbf
400m
3 2 200m

200m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTR003 1 - 55 Hz, 0.0696 g/lbf PASS


1 - 73.5 Hz, 0.1148 g/lbf 2 - 70 Hz, 0.1062 g/lbf
2 - 70.0 Hz, 0.1062 g/lbf 3 - 110 Hz, 0.0466 g/lbf
3 - 66.5 Hz, 0.0781 g/lbf 4 - 140 Hz, 0.0249 g/lbf
200m 500m

400m

1 300m
2
Amplitude g/lbf

Amplitude g/lbf

100m
3
200m

2
100m 1
3

0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTT003 1 - 55 Hz, 0.0459 g/lbf PASS


1 - 105.5 Hz, 0.3752 g/lbf 2 - 70 Hz, 0.0277 g/lbf
2 - 110.5 Hz, 0.1901 g/lbf 3 - 110 Hz, 0.1872 g/lbf
3 - 113.5 Hz, 0.1657 g/lbf 4 - 140 Hz, 0.0275 g/lbf
400m 1 500m

400m
300m

300m
Amplitude g/lbf

Amplitude g/lbf

200m 2
3
200m 3

100m
100m
1
2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1116 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCBA013 1 - 55 Hz, 0.0130 g/lbf PASS


1 - 106.0 Hz, 0.2817 g/lbf 2 - 70 Hz, 0.0140 g/lbf
2 - 103.5 Hz, 0.2436 g/lbf 3 - 110 Hz, 0.1468 g/lbf
3 - 113.0 Hz, 0.1323 g/lbf 4 - 140 Hz, 0.0669 g/lbf
400m 500m

400m
300m 1
2
300m
Amplitude g/lbf

Amplitude g/lbf
200m
3 200m
3
100m
100m

1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBR013 1 - 55 Hz, 0.0246 g/lbf FAIL


1 - 29.0 Hz, 0.9555 g/lbf 2 - 70 Hz, 0.1661 g/lbf
2 - 143.5 Hz, 0.8160 g/lbf 3 - 110 Hz, 0.1293 g/lbf
3 - 139.0 Hz, 0.5450 g/lbf 4 - 140 Hz, 0.5077 g/lbf
1 1 500m
2
800m 400m

600m 3 300m
Amplitude g/lbf

Amplitude g/lbf

400m 200m 2
3
200m 100m
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBT013 1 - 55 Hz, 0.0430 g/lbf FAIL


1 - 65.5 Hz, 0.5407 g/lbf 2 - 70 Hz, 0.2902 g/lbf
2 - 29.0 Hz, 0.2959 g/lbf 3 - 110 Hz, 0.0939 g/lbf
3 - 73.5 Hz, 0.1500 g/lbf 4 - 140 Hz, 0.0661 g/lbf
800m 500m

400m
600m 1
300m 2
Amplitude g/lbf

Amplitude g/lbf

400m
2 200m

200m 3 3
100m
1

0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1117 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCTA013 1 - 55 Hz, 0.0195 g/lbf PASS


1 - 157.0 Hz, 0.2035 g/lbf 2 - 70 Hz, 0.0058 g/lbf
2 - 169.0 Hz, 0.1790 g/lbf 3 - 110 Hz, 0.0333 g/lbf
3 - 162.0 Hz, 0.1552 g/lbf 4 - 140 Hz, 0.0594 g/lbf
400m 500m

400m
300m

300m
Amplitude g/lbf

Amplitude g/lbf
1
200m 2
3
200m

100m
100m
1 3
2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTR013 1 - 55 Hz, 0.1727 g/lbf PASS


1 - 55.5 Hz, 0.1827 g/lbf 2 - 70 Hz, 0.0410 g/lbf
2 - 59.0 Hz, 0.1669 g/lbf 3 - 110 Hz, 0.0239 g/lbf
3 - 61.0 Hz, 0.0944 g/lbf 4 - 140 Hz, 0.0114 g/lbf
200m 1 500m
2
400m

300m
Amplitude g/lbf

Amplitude g/lbf

100m 3

200m 1

100m
2
3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTT013 1 - 55 Hz, 0.0685 g/lbf PASS


1 - 73.0 Hz, 0.2903 g/lbf 2 - 70 Hz, 0.1955 g/lbf
2 - 75.5 Hz, 0.2500 g/lbf 3 - 110 Hz, 0.0452 g/lbf
3 - 78.5 Hz, 0.2053 g/lbf 4 - 140 Hz, 0.0528 g/lbf
400m 500m

1 400m
300m
2
300m
Amplitude g/lbf

Amplitude g/lbf

3
200m
2
200m

100m
100m 1
3

0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1118 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCBA014 1 - 55 Hz, 0.0084 g/lbf PASS


1 - 164.5 Hz, 0.3326 g/lbf 2 - 70 Hz, 0.0052 g/lbf
2 - 157.0 Hz, 0.2526 g/lbf 3 - 110 Hz, 0.0111 g/lbf
3 - 175.5 Hz, 0.1078 g/lbf 4 - 140 Hz, 0.0621 g/lbf
400m 500m
1
400m
300m
2
300m
Amplitude g/lbf

Amplitude g/lbf
200m
200m
3
100m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBR014 1 - 55 Hz, 0.0557 g/lbf PASS


1 - 70.5 Hz, 0.3505 g/lbf 2 - 70 Hz, 0.3134 g/lbf
2 - 77.5 Hz, 0.2986 g/lbf 3 - 110 Hz, 0.0802 g/lbf
3 - 72.0 Hz, 0.2950 g/lbf 4 - 140 Hz, 0.0539 g/lbf
400m 500m
1

32 400m
300m
2
300m
Amplitude g/lbf

Amplitude g/lbf

200m
200m

100m
100m 3
1

0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBT014 1 - 55 Hz, 0.0807 g/lbf PASS


1 - 41.5 Hz, 0.6222 g/lbf 2 - 70 Hz, 0.0895 g/lbf
2 - 164.0 Hz, 0.3443 g/lbf 3 - 110 Hz, 0.0405 g/lbf
3 - 45.0 Hz, 0.3286 g/lbf 4 - 140 Hz, 0.0380 g/lbf
800m 500m

1 400m
600m

300m
Amplitude g/lbf

Amplitude g/lbf

400m 2
3
200m

200m 2
100m 1
3

0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1119 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCTA014 1 - 55 Hz, 0.0075 g/lbf PASS


1 - 196.5 Hz, 0.1021 g/lbf 2 - 70 Hz, 0.0072 g/lbf
2 - 193.5 Hz, 0.0951 g/lbf 3 - 110 Hz, 0.0228 g/lbf
3 - 156.5 Hz, 0.0530 g/lbf 4 - 140 Hz, 0.0273 g/lbf
200m 500m

400m

300m
Amplitude g/lbf

Amplitude g/lbf
1
100m 2
200m
3
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTR014 1 - 55 Hz, 0.0474 g/lbf PASS


1 - 75.5 Hz, 0.2426 g/lbf 2 - 70 Hz, 0.0686 g/lbf
2 - 77.0 Hz, 0.2421 g/lbf 3 - 110 Hz, 0.0154 g/lbf
3 - 46.5 Hz, 0.1885 g/lbf 4 - 140 Hz, 0.0741 g/lbf
400m 500m

400m
300m
12
300m
Amplitude g/lbf

Amplitude g/lbf

200m 3
200m

100m
100m 2
1
3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTT014 1 - 55 Hz, 0.1897 g/lbf PASS


1 - 119.0 Hz, 0.4204 g/lbf 2 - 70 Hz, 0.0364 g/lbf
2 - 127.0 Hz, 0.3351 g/lbf 3 - 110 Hz, 0.1782 g/lbf
3 - 134.5 Hz, 0.2870 g/lbf 4 - 140 Hz, 0.2068 g/lbf
500m 500m
1
400m 400m
2
300m 3 300m
Amplitude g/lbf

Amplitude g/lbf

200m 200m 1 3

100m 100m
2

0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1120 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCBA015 1 - 55 Hz, 0.0029 g/lbf PASS


1 - 165.5 Hz, 0.2270 g/lbf 2 - 70 Hz, 0.0096 g/lbf
2 - 160.5 Hz, 0.1811 g/lbf 3 - 110 Hz, 0.0067 g/lbf
3 - 146.0 Hz, 0.1459 g/lbf 4 - 140 Hz, 0.0589 g/lbf
400m 500m

400m
300m

1 300m
Amplitude g/lbf

Amplitude g/lbf
200m 2
3 200m

100m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBR015 1 - 55 Hz, 0.1451 g/lbf PASS


1 - 45.0 Hz, 0.9140 g/lbf 2 - 70 Hz, 0.0884 g/lbf
2 - 47.5 Hz, 0.3602 g/lbf 3 - 110 Hz, 0.0607 g/lbf
3 - 50.5 Hz, 0.2657 g/lbf 4 - 140 Hz, 0.0460 g/lbf
1 1 500m

800m 400m

600m 300m
Amplitude g/lbf

Amplitude g/lbf

400m 2 200m
3 1

200m 100m 2
3

0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBT015 1 - 55 Hz, 0.0724 g/lbf PASS


1 - 33.0 Hz, 0.7434 g/lbf 2 - 70 Hz, 0.0512 g/lbf
2 - 34.5 Hz, 0.5085 g/lbf 3 - 110 Hz, 0.0419 g/lbf
3 - 45.5 Hz, 0.0980 g/lbf 4 - 140 Hz, 0.0643 g/lbf
800m 1 500m

400m
600m
2
300m
Amplitude g/lbf

Amplitude g/lbf

400m
200m

200m
100m 1
3 2 3

0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1121 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCTA015 1 - 55 Hz, 0.0005 g/lbf PASS


1 - 146.5 Hz, 0.1094 g/lbf 2 - 70 Hz, 0.0216 g/lbf
2 - 91.5 Hz, 0.1089 g/lbf 3 - 110 Hz, 0.1056 g/lbf
3 - 108.5 Hz, 0.1082 g/lbf 4 - 140 Hz, 0.1000 g/lbf
200m 500m

400m

2 3 1 300m
Amplitude g/lbf

Amplitude g/lbf
100m
200m

3
100m
2
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTR015 1 - 55 Hz, 0.0695 g/lbf PASS


1 - 110.5 Hz, 0.2608 g/lbf 2 - 70 Hz, 0.0445 g/lbf
2 - 116.0 Hz, 0.2452 g/lbf 3 - 110 Hz, 0.2539 g/lbf
3 - 119.0 Hz, 0.2242 g/lbf 4 - 140 Hz, 0.0891 g/lbf
400m 500m

400m
300m
1
2
3 300m
Amplitude g/lbf

Amplitude g/lbf

3
200m
200m

100m
100m 1
2

0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTT015 1 - 55 Hz, 0.1175 g/lbf PASS


1 - 57.5 Hz, 0.1352 g/lbf 2 - 70 Hz, 0.0766 g/lbf
2 - 165.0 Hz, 0.0940 g/lbf 3 - 110 Hz, 0.0707 g/lbf
3 - 68.5 Hz, 0.0866 g/lbf 4 - 140 Hz, 0.0542 g/lbf
200m 500m

400m
1
300m
Amplitude g/lbf

Amplitude g/lbf

100m 2
3
200m
1
100m 2 3

0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1122 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCBA025 1 - 55 Hz, 0.0153 g/lbf PASS


1 - 103.5 Hz, 0.2325 g/lbf 2 - 70 Hz, 0.0158 g/lbf
2 - 97.0 Hz, 0.2030 g/lbf 3 - 110 Hz, 0.0983 g/lbf
3 - 86.5 Hz, 0.1206 g/lbf 4 - 140 Hz, 0.0653 g/lbf
400m 500m

400m
300m
1 300m
Amplitude g/lbf

Amplitude g/lbf
2
200m
200m
3
100m 3
100m

1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBR025 1 - 55 Hz, 0.0211 g/lbf PASS


1 - 151.0 Hz, 0.5533 g/lbf 2 - 70 Hz, 0.0991 g/lbf
2 - 28.0 Hz, 0.5405 g/lbf 3 - 110 Hz, 0.0955 g/lbf
3 - 66.0 Hz, 0.1342 g/lbf 4 - 140 Hz, 0.1188 g/lbf
800m 500m

400m
600m 2 1

300m
Amplitude g/lbf

Amplitude g/lbf

400m
200m

200m 2 3
3 100m
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBT025 1 - 55 Hz, 0.0684 g/lbf FAIL


1 - 67.0 Hz, 0.5156 g/lbf 2 - 70 Hz, 0.4775 g/lbf
2 - 70.0 Hz, 0.4775 g/lbf 3 - 110 Hz, 0.0761 g/lbf
3 - 66.0 Hz, 0.4663 g/lbf 4 - 140 Hz, 0.0330 g/lbf
800m 500m 2

400m
600m
1
32 300m
Amplitude g/lbf

Amplitude g/lbf

400m
200m

200m
100m 1 3

0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1123 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCTA025 1 - 55 Hz, 0.0099 g/lbf PASS


1 - 193.5 Hz, 0.5341 g/lbf 2 - 70 Hz, 0.0065 g/lbf
2 - 197.0 Hz, 0.5256 g/lbf 3 - 110 Hz, 0.0153 g/lbf
3 - 41.5 Hz, 0.1497 g/lbf 4 - 140 Hz, 0.0310 g/lbf
800m 500m

400m
600m
12
300m
Amplitude g/lbf

Amplitude g/lbf
400m
200m

200m 3
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTR025 1 - 55 Hz, 0.0358 g/lbf PASS


1 - 79.0 Hz, 0.1401 g/lbf 2 - 70 Hz, 0.0781 g/lbf
2 - 84.0 Hz, 0.1392 g/lbf 3 - 110 Hz, 0.0417 g/lbf
3 - 82.0 Hz, 0.1256 g/lbf 4 - 140 Hz, 0.0201 g/lbf
200m 500m

400m
12
3
300m
Amplitude g/lbf

Amplitude g/lbf

100m
200m

100m 2
1 3

0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTT025 1 - 55 Hz, 0.0025 g/lbf PASS


1 - 102.5 Hz, 0.2872 g/lbf 2 - 70 Hz, 0.0160 g/lbf
2 - 112.5 Hz, 0.2644 g/lbf 3 - 110 Hz, 0.1623 g/lbf
3 - 41.5 Hz, 0.2145 g/lbf 4 - 140 Hz, 0.0594 g/lbf
400m 500m

400m
300m 1
2
3 300m
Amplitude g/lbf

Amplitude g/lbf

200m
200m 3
100m
100m

1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1124 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCBA026 1 - 55 Hz, 0.0074 g/lbf PASS


1 - 112.5 Hz, 0.2168 g/lbf 2 - 70 Hz, 0.0174 g/lbf
2 - 102.5 Hz, 0.1026 g/lbf 3 - 110 Hz, 0.1834 g/lbf
3 - 86.5 Hz, 0.0806 g/lbf 4 - 140 Hz, 0.0344 g/lbf
400m 500m

400m
300m

1 300m
Amplitude g/lbf

Amplitude g/lbf
200m
200m 3
2
100m 3
100m

1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBR026 1 - 55 Hz, 0.2305 g/lbf PASS


1 - 23.0 Hz, 0.6161 g/lbf 2 - 70 Hz, 0.0859 g/lbf
2 - 53.0 Hz, 0.4366 g/lbf 3 - 110 Hz, 0.0612 g/lbf
3 - 54.0 Hz, 0.4031 g/lbf 4 - 140 Hz, 0.0379 g/lbf
800m 500m

1 400m
600m

2 300m
Amplitude g/lbf

Amplitude g/lbf

3
400m 1
200m

200m
100m 2
3

0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBT026 1 - 55 Hz, 0.2626 g/lbf PASS


1 - 23.0 Hz, 0.7561 g/lbf 2 - 70 Hz, 0.0971 g/lbf
2 - 53.0 Hz, 0.4696 g/lbf 3 - 110 Hz, 0.0691 g/lbf
3 - 54.0 Hz, 0.3982 g/lbf 4 - 140 Hz, 0.0530 g/lbf
800m 1 500m

400m
600m
2
300m
Amplitude g/lbf

Amplitude g/lbf

3 1
400m
200m

200m 2
100m 3

0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1125 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCTA026 1 - 55 Hz, 0.0124 g/lbf PASS


1 - 65.0 Hz, 0.0356 g/lbf 2 - 70 Hz, 0.0315 g/lbf
2 - 68.5 Hz, 0.0351 g/lbf 3 - 110 Hz, 0.0069 g/lbf
3 - 189.0 Hz, 0.0324 g/lbf 4 - 140 Hz, 0.0103 g/lbf
40m 500m
12
3
400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf
20m
200m

10m
100m
2
1 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTR026 1 - 55 Hz, 0.0557 g/lbf PASS


1 - 57.5 Hz, 0.1423 g/lbf 2 - 70 Hz, 0.0446 g/lbf
2 - 45.5 Hz, 0.1248 g/lbf 3 - 110 Hz, 0.0540 g/lbf
3 - 101.0 Hz, 0.1017 g/lbf 4 - 140 Hz, 0.0137 g/lbf
200m 500m

400m
1
2
300m
Amplitude g/lbf

Amplitude g/lbf

3
100m
200m

100m
1 2 3

0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTT026 1 - 55 Hz, 0.0798 g/lbf PASS


1 - 151.0 Hz, 0.6624 g/lbf 2 - 70 Hz, 0.1912 g/lbf
2 - 156.0 Hz, 0.4227 g/lbf 3 - 110 Hz, 0.0233 g/lbf
3 - 159.0 Hz, 0.3381 g/lbf 4 - 140 Hz, 0.2134 g/lbf
800m 500m
1
400m
600m

300m
Amplitude g/lbf

Amplitude g/lbf

2
400m 3
200m 2

200m
100m 1
3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1126 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCBA027 1 - 55 Hz, 0.0096 g/lbf PASS


1 - 106.5 Hz, 0.2284 g/lbf 2 - 70 Hz, 0.0175 g/lbf
2 - 116.0 Hz, 0.2182 g/lbf 3 - 110 Hz, 0.1027 g/lbf
3 - 101.5 Hz, 0.1509 g/lbf 4 - 140 Hz, 0.0569 g/lbf
400m 500m

400m
300m

1 2 300m
Amplitude g/lbf

Amplitude g/lbf
200m
3 200m

100m 3
100m

1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBR027 1 - 55 Hz, 0.0185 g/lbf PASS


1 - 107.0 Hz, 0.3666 g/lbf 2 - 70 Hz, 0.0339 g/lbf
2 - 86.5 Hz, 0.2813 g/lbf 3 - 110 Hz, 0.1811 g/lbf
3 - 102.0 Hz, 0.2248 g/lbf 4 - 140 Hz, 0.0853 g/lbf
400m 1 500m

400m
300m 2

3 300m
Amplitude g/lbf

Amplitude g/lbf

200m
200m 3

100m
100m
1 2

0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBT027 1 - 55 Hz, 0.0187 g/lbf PASS


1 - 82.0 Hz, 0.4120 g/lbf 2 - 70 Hz, 0.0608 g/lbf
2 - 76.0 Hz, 0.2797 g/lbf 3 - 110 Hz, 0.0649 g/lbf
3 - 86.5 Hz, 0.2410 g/lbf 4 - 140 Hz, 0.0355 g/lbf
500m 500m
1
400m 400m

300m 2 300m
Amplitude g/lbf

Amplitude g/lbf

200m 200m

100m 100m 3
2
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1127 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCTA027 1 - 55 Hz, 0.0062 g/lbf PASS


1 - 149.0 Hz, 0.0798 g/lbf 2 - 70 Hz, 0.0162 g/lbf
2 - 193.0 Hz, 0.0487 g/lbf 3 - 110 Hz, 0.0119 g/lbf
3 - 74.5 Hz, 0.0483 g/lbf 4 - 140 Hz, 0.0315 g/lbf
80m 500m

400m
60m
3 2
300m
Amplitude g/lbf

Amplitude g/lbf
40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTR027 1 - 55 Hz, 0.0049 g/lbf PASS


1 - 182.0 Hz, 0.3193 g/lbf 2 - 70 Hz, 0.0134 g/lbf
2 - 186.0 Hz, 0.2846 g/lbf 3 - 110 Hz, 0.0505 g/lbf
3 - 193.5 Hz, 0.2294 g/lbf 4 - 140 Hz, 0.1236 g/lbf
400m 500m

1
400m
300m 2

3 300m
Amplitude g/lbf

Amplitude g/lbf

200m
200m

100m
100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTT027 1 - 55 Hz, 0.0218 g/lbf PASS


1 - 86.5 Hz, 0.2232 g/lbf 2 - 70 Hz, 0.0468 g/lbf
2 - 152.0 Hz, 0.2182 g/lbf 3 - 110 Hz, 0.0904 g/lbf
3 - 84.5 Hz, 0.1933 g/lbf 4 - 140 Hz, 0.0363 g/lbf
400m 500m

400m
300m

1 2 300m
Amplitude g/lbf

Amplitude g/lbf

3
200m
200m

100m 3
100m
2
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1128 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCBA037 1 - 55 Hz, 0.0058 g/lbf PASS


1 - 154.5 Hz, 0.1357 g/lbf 2 - 70 Hz, 0.0035 g/lbf
2 - 161.5 Hz, 0.0837 g/lbf 3 - 110 Hz, 0.0197 g/lbf
3 - 166.0 Hz, 0.0749 g/lbf 4 - 140 Hz, 0.0147 g/lbf
200m 500m

400m
1

300m
Amplitude g/lbf

Amplitude g/lbf
100m 2
3 200m

100m

1 2 5 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBR037 1 - 55 Hz, 0.0258 g/lbf FAIL


1 - 34.0 Hz, 0.7500 g/lbf 2 - 70 Hz, 0.1261 g/lbf
2 - 137.5 Hz, 0.5080 g/lbf 3 - 110 Hz, 0.1006 g/lbf
3 - 140.5 Hz, 0.4285 g/lbf 4 - 140 Hz, 0.4228 g/lbf
800m 1 500m

400m
600m
2
3 300m
Amplitude g/lbf

Amplitude g/lbf

400m
200m
2
200m 3
100m
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBT037 1 - 55 Hz, 0.0254 g/lbf PASS


1 - 34.0 Hz, 0.5307 g/lbf 2 - 70 Hz, 0.1011 g/lbf
2 - 141.0 Hz, 0.1547 g/lbf 3 - 110 Hz, 0.0489 g/lbf
3 - 38.5 Hz, 0.1427 g/lbf 4 - 140 Hz, 0.1235 g/lbf
800m 500m

400m
600m
1
300m
Amplitude g/lbf

Amplitude g/lbf

400m
200m

200m 3 2 2
100m
3
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1129 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCTA037 1 - 55 Hz, 0.0030 g/lbf PASS


1 - 186.0 Hz, 0.1997 g/lbf 2 - 70 Hz, 0.0035 g/lbf
2 - 165.0 Hz, 0.1246 g/lbf 3 - 110 Hz, 0.0147 g/lbf
3 - 162.5 Hz, 0.1224 g/lbf 4 - 140 Hz, 0.0216 g/lbf
200m 500m

400m

32
300m
Amplitude g/lbf

Amplitude g/lbf
100m
200m

100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTR037 1 - 55 Hz, 0.0713 g/lbf PASS


1 - 187.5 Hz, 0.1340 g/lbf 2 - 70 Hz, 0.0845 g/lbf
2 - 193.5 Hz, 0.1331 g/lbf 3 - 110 Hz, 0.0600 g/lbf
3 - 166.0 Hz, 0.1277 g/lbf 4 - 140 Hz, 0.0065 g/lbf
200m 500m

400m
12
3
300m
Amplitude g/lbf

Amplitude g/lbf

100m
200m

100m 1 2
3

0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTT037 1 - 55 Hz, 0.0034 g/lbf PASS


1 - 36.0 Hz, 0.2307 g/lbf 2 - 70 Hz, 0.0457 g/lbf
2 - 102.0 Hz, 0.1833 g/lbf 3 - 110 Hz, 0.1221 g/lbf
3 - 109.0 Hz, 0.1257 g/lbf 4 - 140 Hz, 0.0624 g/lbf
400m 500m

400m
300m
1 300m
Amplitude g/lbf

Amplitude g/lbf

200m 2
200m
3
3
100m
100m
2
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1130 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCBA038 1 - 55 Hz, 0.0629 g/lbf PASS


1 - 72.5 Hz, 0.0983 g/lbf 2 - 70 Hz, 0.0587 g/lbf
2 - 93.5 Hz, 0.0804 g/lbf 3 - 110 Hz, 0.0446 g/lbf
3 - 61.5 Hz, 0.07721 g/lbf 4 - 140 Hz, 0.0313 g/lbf
100m 500m

3 2
400m

300m
Amplitude g/lbf

Amplitude g/lbf
50m
200m

100m 1 2 3

0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBR038 1 - 55 Hz, 0.0811 g/lbf PASS


1 - 40.5 Hz, 0.3668 g/lbf 2 - 70 Hz, 0.1028 g/lbf
2 - 18.5 Hz, 0.3226 g/lbf 3 - 110 Hz, 0.0438 g/lbf
3 - 42.5 Hz, 0.2457 g/lbf 4 - 140 Hz, 0.0259 g/lbf
400m 1 500m

2
400m
300m
3
300m
Amplitude g/lbf

Amplitude g/lbf

200m
200m

100m 2
100m 1
3

0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBT038 1 - 55 Hz, 0.0915 g/lbf PASS


1 - 18.5 Hz, 0.4262 g/lbf 2 - 70 Hz, 0.0715 g/lbf
2 - 40.5 Hz, 0.3741 g/lbf 3 - 110 Hz, 0.0750 g/lbf
3 - 42.5 Hz, 0.3095 g/lbf 4 - 140 Hz, 0.0545 g/lbf
500m 500m
1
400m 2 400m

3
300m 300m
Amplitude g/lbf

Amplitude g/lbf

200m 200m

100m 100m 1 3
2

0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1131 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCTA038 1 - 55 Hz, 0.0119 g/lbf PASS


1 - 122.5 Hz, 0.0491 g/lbf 2 - 70 Hz, 0.0087 g/lbf
2 - 152.0 Hz, 0.0446 g/lbf 3 - 110 Hz, 0.0252 g/lbf
3 - 128.5 Hz, 0.0418 g/lbf 4 - 140 Hz, 0.0163 g/lbf
200m 500m

400m

300m
Amplitude g/lbf

Amplitude g/lbf
100m
200m
1 2
3
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTR038 1 - 55 Hz, 0.1277 g/lbf PASS


1 - 109.5 Hz, 0.2529 g/lbf 2 - 70 Hz, 0.0229 g/lbf
2 - 107.5 Hz, 0.2388 g/lbf 3 - 110 Hz, 0.2505 g/lbf
3 - 56.0 Hz, 0.1514 g/lbf 4 - 140 Hz, 0.0677 g/lbf
400m 500m

400m
300m
1
2
300m
Amplitude g/lbf

Amplitude g/lbf

3
200m
3 200m
1
100m
100m
2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTT038 1 - 55 Hz, 0.0671 g/lbf PASS


1 - 111.0 Hz, 0.3912 g/lbf 2 - 70 Hz, 0.0561 g/lbf
2 - 38.5 Hz, 0.3852 g/lbf 3 - 110 Hz, 0.3683 g/lbf
3 - 93.5 Hz, 0.1821 g/lbf 1 4 - 140 Hz, 0.1117 g/lbf
400m 2 500m

400m 3
300m

300m
Amplitude g/lbf

Amplitude g/lbf

200m 3
200m

100m
100m 1 2

0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1132 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCBA039 1 - 55 Hz, 0.0087 g/lbf PASS


1 - 185.5 Hz, 0.3204 g/lbf 2 - 70 Hz, 0.0075 g/lbf
2 - 151.5 Hz, 0.1416 g/lbf 3 - 110 Hz, 0.0241 g/lbf
3 - 171.5 Hz, 0.1040 g/lbf 4 - 140 Hz, 0.0524 g/lbf
400m 500m

1
400m
300m

300m
Amplitude g/lbf

Amplitude g/lbf
200m
2 200m
3
100m
100m

1 3
2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBR039 1 - 55 Hz, 0.1817 g/lbf PASS


1 - 52.5 Hz, 0.7019 g/lbf 2 - 70 Hz, 0.0871 g/lbf
2 - 38.0 Hz, 0.3610 g/lbf 3 - 110 Hz, 0.0722 g/lbf
3 - 178.5 Hz, 0.3138 g/lbf 4 - 140 Hz, 0.0939 g/lbf
800m 500m
1

400m
600m

300m
Amplitude g/lbf

Amplitude g/lbf

400m 2
3
200m 1

200m
100m 2 3

0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBT039 1 - 55 Hz, 0.0900 g/lbf PASS


1 - 37.5 Hz, 0.5925 g/lbf 2 - 70 Hz, 0.0600 g/lbf
2 - 53.0 Hz, 0.2399 g/lbf 3 - 110 Hz, 0.0467 g/lbf
3 - 39.0 Hz, 0.1791 g/lbf 4 - 140 Hz, 0.0459 g/lbf
800m 500m

1 400m
600m

300m
Amplitude g/lbf

Amplitude g/lbf

400m
200m
2
200m 3
100m 1
2 3

0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1133 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCTA039 1 - 55 Hz, 0.0037 g/lbf PASS


1 - 107.0 Hz, 0.0928 g/lbf 2 - 70 Hz, 0.0099 g/lbf
2 - 102.0 Hz, 0.0838 g/lbf 3 - 110 Hz, 0.0442 g/lbf
3 - 96.0 Hz, 0.0514 g/lbf 4 - 140 Hz, 0.0303 g/lbf
100m 1 500m
2
400m

300m
Amplitude g/lbf

Amplitude g/lbf
3
50m
200m

100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTR039 1 - 55 Hz, 0.0382 g/lbf PASS


1 - 96.0 Hz, 0.1845 g/lbf 2 - 70 Hz, 0.0127 g/lbf
2 - 92.0 Hz, 0.1449 g/lbf 3 - 110 Hz, 0.0567 g/lbf
3 - 100.0 Hz, 0.0769 g/lbf 4 - 140 Hz, 0.0330 g/lbf
200m 1 500m

2 400m

300m
Amplitude g/lbf

Amplitude g/lbf

100m
3
200m

100m
3
1
2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTT039 1 - 55 Hz, 0.0109 g/lbf PASS


1 - 141.5 Hz, 0.2938 g/lbf 2 - 70 Hz, 0.0158 g/lbf
2 - 140.5 Hz, 0.2929 g/lbf 3 - 110 Hz, 0.0626 g/lbf
3 - 143.0 Hz, 0.2871 g/lbf 4 - 140 Hz, 0.2860 g/lbf
400m 500m

213 400m
300m

300m
Amplitude g/lbf

Amplitude g/lbf

200m
200m

100m
100m 3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1134 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCBA049 1 - 55 Hz, 0.0069 g/lbf PASS


1 - 177.5 Hz, 0.1980 g/lbf 2 - 70 Hz, 0.0259 g/lbf
2 - 187.5 Hz, 0.1558 g/lbf 3 - 110 Hz, 0.0097 g/lbf
3 - 168.5 Hz, 0.1497 g/lbf 1 4 - 140 Hz, 0.0200 g/lbf
200m 500m

2 400m
3

300m
Amplitude g/lbf

Amplitude g/lbf
100m
200m

100m
2
1 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBR049 1 - 55 Hz, 0.0319 g/lbf PASS


1 - 69.0 Hz, 0.3779 g/lbf 2 - 70 Hz, 0.2030 g/lbf
2 - 73.0 Hz, 0.2865 g/lbf 3 - 110 Hz, 0.0180 g/lbf
3 - 65.5 Hz, 0.1574 g/lbf 4 - 140 Hz, 0.0622 g/lbf
400m 1 500m

400m
300m 2

300m
Amplitude g/lbf

Amplitude g/lbf

200m
3 2
200m

100m
100m
1 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBT049 1 - 55 Hz, 0.0375 g/lbf PASS


1 - 69.0 Hz, 0.2862 g/lbf 2 - 70 Hz, 0.2062 g/lbf
2 - 126.0 Hz, 0.2614 g/lbf 3 - 110 Hz, 0.0666 g/lbf
3 - 118.5 Hz, 0.2347 g/lbf 4 - 140 Hz, 0.1159 g/lbf
400m 500m

400m
300m 1
2
3
300m
Amplitude g/lbf

Amplitude g/lbf

200m
2
200m

100m
100m 3
1

0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1135 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCTA049 1 - 55 Hz, 0.0111 g/lbf PASS


1 - 193.0 Hz, 0.0786 g/lbf 2 - 70 Hz, 0.0235 g/lbf
2 - 189.0 Hz, 0.0673 g/lbf 3 - 110 Hz, 0.0092 g/lbf
3 - 168.0 Hz, 0.0629 g/lbf 1 4 - 140 Hz, 0.0244 g/lbf
80m 500m
2
3
400m
60m

300m
Amplitude g/lbf

Amplitude g/lbf
40m
200m

20m
100m

1 2
3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTR049 1 - 55 Hz, 0.0169 g/lbf PASS


1 - 187.5 Hz, 0.0652 g/lbf 2 - 70 Hz, 0.0468 g/lbf
2 - 126.5 Hz, 0.0650 g/lbf 3 - 110 Hz, 0.0411 g/lbf
3 - 190.0 Hz, 0.0648 g/lbf 4 - 140 Hz, 0.0196 g/lbf
80m 500m
2 13
400m
60m

300m
Amplitude g/lbf

Amplitude g/lbf

40m
200m

20m
100m
2 3
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTT049 1 - 55 Hz, 0.0122 g/lbf PASS


1 - 142.0 Hz, 0.1719 g/lbf 2 - 70 Hz, 0.0153 g/lbf
2 - 163.5 Hz, 0.1465 g/lbf 3 - 110 Hz, 0.0778 g/lbf
3 - 158.0 Hz, 0.1432 g/lbf 4 - 140 Hz, 0.1076 g/lbf
200m 500m
1
400m
32

300m
Amplitude g/lbf

Amplitude g/lbf

100m
200m

100m 3

1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1136 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCBA050 1 - 55 Hz, 0.0102 g/lbf PASS


1 - 103.0 Hz, 0.2021 g/lbf 2 - 70 Hz, 0.0185 g/lbf
2 - 107.0 Hz, 0.1958 g/lbf 3 - 110 Hz, 0.1172 g/lbf
3 - 105.5 Hz, 0.1888 g/lbf 4 - 140 Hz, 0.0491 g/lbf
400m 500m

400m
300m

300m
Amplitude g/lbf

Amplitude g/lbf
12
200m 3
200m

100m 3
100m

1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBR050 1 - 55 Hz, 0.0780 g/lbf PASS


1 - 42.0 Hz, 0.9823 g/lbf 2 - 70 Hz, 0.0271 g/lbf
2 - 40.5 Hz, 0.3706 g/lbf 3 - 110 Hz, 0.0521 g/lbf
3 - 92.5 Hz, 0.1898 g/lbf 4 - 140 Hz, 0.0914 g/lbf
1
1 500m

800m 400m

600m 300m
Amplitude g/lbf

Amplitude g/lbf

400m 2 200m

3
200m 100m 1
3
2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBT050 1 - 55 Hz, 0.0126 g/lbf PASS


1 - 92.5 Hz, 0.4792 g/lbf 2 - 70 Hz, 0.1167 g/lbf
2 - 42.0 Hz, 0.3550 g/lbf 3 - 110 Hz, 0.0888 g/lbf
3 - 118.5 Hz, 0.2270 g/lbf 4 - 140 Hz, 0.1211 g/lbf
500m 1 500m

400m 400m
2

300m 300m
Amplitude g/lbf

Amplitude g/lbf

3
200m 200m
2
100m 100m 3

1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1137 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCTA050 1 - 55 Hz, 0.0021 g/lbf PASS


1 - 169.0 Hz, 0.0219 g/lbf 2 - 70 Hz, 0.0038 g/lbf
2 - 179.0 Hz, 0.0189 g/lbf 3 - 110 Hz, 0.0095 g/lbf
3 - 96.0 Hz, 0.0177 g/lbf 4 - 140 Hz, 0.0049 g/lbf
40m 500m

400m
30m

1 300m
Amplitude g/lbf

Amplitude g/lbf
20m 3 2
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTR050 1 - 55 Hz, 0.0141 g/lbf PASS


1 - 142.5 Hz, 0.1718 g/lbf 2 - 70 Hz, 0.0269 g/lbf
2 - 162.0 Hz, 0.1523 g/lbf 3 - 110 Hz, 0.0120 g/lbf
3 - 166.5 Hz, 0.1325 g/lbf 4 - 140 Hz, 0.1232 g/lbf
200m 500m
1
2 400m
3
300m
Amplitude g/lbf

Amplitude g/lbf

100m
200m

100m

1 2
3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTT050 1 - 55 Hz, 0.0256 g/lbf FAIL


1 - 110.5 Hz, 0.5462 g/lbf 2 - 70 Hz, 0.0528 g/lbf
2 - 109.5 Hz, 0.5393 g/lbf 3 - 110 Hz, 0.5282 g/lbf
3 - 95.5 Hz, 0.2609 g/lbf 4 - 140 Hz, 0.0478 g/lbf
800m 500m

400m
600m 21
300m
Amplitude g/lbf

Amplitude g/lbf

400m

3 200m

200m
100m
2
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1138 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCBA051 1 - 55 Hz, 0.0228 g/lbf PASS


1 - 189.5 Hz, 0.2023 g/lbf 2 - 70 Hz, 0.0251 g/lbf
2 - 162.0 Hz, 0.1786 g/lbf 3 - 110 Hz, 0.0135 g/lbf
3 - 185.5 Hz, 0.1606 g/lbf 4 - 140 Hz, 0.1063 g/lbf
400m 500m

400m
300m

300m
Amplitude g/lbf

Amplitude g/lbf
1
200m 2
3
200m

100m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBR051 1 - 55 Hz, 0.0478 g/lbf PASS


1 - 81.5 Hz, 0.8878 g/lbf 2 - 70 Hz, 0.1566 g/lbf
2 - 76.0 Hz, 0.3746 g/lbf 3 - 110 Hz, 0.1012 g/lbf
3 - 73.0 Hz, 0.2522 g/lbf 4 - 140 Hz, 0.0727 g/lbf
1 500m
1

800m 400m

600m 300m
Amplitude g/lbf

Amplitude g/lbf

400m 2 200m
2
3
3
200m 100m
1

0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBT051 1 - 55 Hz, 0.5988 g/lbf FAIL


1 - 54.0 Hz, 2.2031 g/lbf 2 - 70 Hz, 0.0878 g/lbf
2 - 65.5 Hz, 0.1161 g/lbf 3 - 110 Hz, 0.0510 g/lbf
3 - 72.0 Hz, 0.0858 g/lbf 4 - 140 Hz, 0.0435 g/lbf
4 500m

400m
3

1 300m
Amplitude g/lbf

Amplitude g/lbf

2
200m

1 2
100m
3
23
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1139 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCTA051 1 - 55 Hz, 0.0067 g/lbf PASS


1 - 109.0 Hz, 0.3134 g/lbf 2 - 70 Hz, 0.0146 g/lbf
2 - 113.0 Hz, 0.1225 g/lbf 3 - 110 Hz, 0.2857 g/lbf
3 - 102.0 Hz, 0.0890 g/lbf 4 - 140 Hz, 0.0328 g/lbf
400m 500m

1 400m
300m

300m 3
Amplitude g/lbf

Amplitude g/lbf
200m
200m
2
100m 3
100m

1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTR051 1 - 55 Hz, 0.0059 g/lbf PASS


1 - 111.0 Hz, 0.1245 g/lbf 2 - 70 Hz, 0.0089 g/lbf
2 - 95.0 Hz, 0.0560 g/lbf 3 - 110 Hz, 0.1143 g/lbf
3 - 88.5 Hz, 0.0356 g/lbf 4 - 140 Hz, 0.0146 g/lbf
200m 500m

400m

1
300m
Amplitude g/lbf

Amplitude g/lbf

100m
200m
2
3
3 100m

1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTT051 1 - 55 Hz, 0.0069 g/lbf PASS


1 - 161.5 Hz, 0.2716 g/lbf 2 - 70 Hz, 0.0113 g/lbf
2 - 166.0 Hz, 0.2273 g/lbf 3 - 110 Hz, 0.0604 g/lbf
3 - 172.0 Hz, 0.1836 g/lbf 4 - 140 Hz, 0.0677 g/lbf
400m 500m

400m
300m 1
2 300m
Amplitude g/lbf

Amplitude g/lbf

200m 3
200m

100m
100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1140 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCBA061 1 - 55 Hz, 0.0150 g/lbf PASS


1 - 82.0 Hz, 0.1840 g/lbf 2 - 70 Hz, 0.0419 g/lbf
2 - 83.5 Hz, 0.1805 g/lbf 3 - 110 Hz, 0.0900 g/lbf
3 - 103.0 Hz, 0.1440 g/lbf 4 - 140 Hz, 0.0448 g/lbf
200m 12 500m

400m
3

300m
Amplitude g/lbf

Amplitude g/lbf
100m
200m

100m 3
2
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBR061 1 - 55 Hz, 0.0181 g/lbf PASS


1 - 82.0 Hz, 0.2353 g/lbf 2 - 70 Hz, 0.0828 g/lbf
2 - 71.5 Hz, 0.1241 g/lbf 3 - 110 Hz, 0.0210 g/lbf
3 - 198.5 Hz, 0.1161 g/lbf 4 - 140 Hz, 0.0049 g/lbf
400m 500m

400m
300m
1
300m
Amplitude g/lbf

Amplitude g/lbf

200m
200m
2
100m
100m 2

1 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBT061 1 - 55 Hz, 0.0098 g/lbf PASS


1 - 106.5 Hz, 0.1564 g/lbf 2 - 70 Hz, 0.0296 g/lbf
2 - 102.0 Hz, 0.1328 g/lbf 3 - 110 Hz, 0.1069 g/lbf
3 - 119.0 Hz, 0.1149 g/lbf 4 - 140 Hz, 0.0434 g/lbf
200m 500m

1 400m
2
3 300m
Amplitude g/lbf

Amplitude g/lbf

100m
200m

3
100m
2
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1141 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCTA061 1 - 55 Hz, 0.0055 g/lbf PASS


1 - 155.5 Hz, 0.1146 g/lbf 2 - 70 Hz, 0.0120 g/lbf
2 - 156.5 Hz, 0.1133 g/lbf 3 - 110 Hz, 0.0272 g/lbf
3 - 147.0 Hz, 0.1025 g/lbf 4 - 140 Hz, 0.0598 g/lbf
200m 500m

400m

12 300m
Amplitude g/lbf

Amplitude g/lbf
3
100m
200m

100m

2 3
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTR061 1 - 55 Hz, 0.0137 g/lbf PASS


1 - 47.5 Hz, 0.2486 g/lbf 2 - 70 Hz, 0.0312 g/lbf
2 - 168.0 Hz, 0.1722 g/lbf 3 - 110 Hz, 0.0285 g/lbf
3 - 177.5 Hz, 0.1285 g/lbf 4 - 140 Hz, 0.0536 g/lbf
400m 500m

400m
300m
1
300m
Amplitude g/lbf

Amplitude g/lbf

200m 2
3 200m

100m
100m
2 3
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTT061 1 - 55 Hz, 0.0465 g/lbf PASS


1 - 168.5 Hz, 0.1968 g/lbf 2 - 70 Hz, 0.1035 g/lbf
2 - 156.5 Hz, 0.1599 g/lbf 3 - 110 Hz, 0.0201 g/lbf
3 - 155.5 Hz, 0.1581 g/lbf 1 4 - 140 Hz, 0.0330 g/lbf
200m 500m

32
400m

300m
Amplitude g/lbf

Amplitude g/lbf

100m
200m

2
100m
1
3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1142 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCBA062 1 - 55 Hz, 0.0059 g/lbf PASS


1 - 92.5 Hz, 0.1595 g/lbf 2 - 70 Hz, 0.0229 g/lbf
2 - 99.5 Hz, 0.1454 g/lbf 3 - 110 Hz, 0.0581 g/lbf
3 - 18.0 Hz, 0.1304 g/lbf 4 - 140 Hz, 0.0946 g/lbf
200m 500m

1
2 400m
3
300m
Amplitude g/lbf

Amplitude g/lbf
100m
200m

100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBR062 1 - 55 Hz, 0.0800 g/lbf PASS


1 - 34.5 Hz, 0.8232 g/lbf 2 - 70 Hz, 0.0803 g/lbf
2 - 18.0 Hz, 0.5605 g/lbf 3 - 110 Hz, 0.0250 g/lbf
3 - 93.0 Hz, 0.2287 g/lbf 4 - 140 Hz, 0.0629 g/lbf
1 500m
1
800m 400m

600m 2 300m
Amplitude g/lbf

Amplitude g/lbf

400m 200m
3
200m 100m 1 2
3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBT062 1 - 55 Hz, 0.0469 g/lbf PASS


1 - 18.0 Hz, 1.4714 g/lbf 2 - 70 Hz, 0.0405 g/lbf
2 - 93.5 Hz, 0.2021 g/lbf 3 - 110 Hz, 0.0562 g/lbf
3 - 36.0 Hz, 0.1770 g/lbf 4 - 140 Hz, 0.1466 g/lbf
2 500m

1 400m
1.5

300m
Amplitude g/lbf

Amplitude g/lbf

1
200m

500m
100m
3 2 1 2 3

0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1143 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCTA062 1 - 55 Hz, 0.0051 g/lbf PASS


1 - 181.5 Hz, 0.2212 g/lbf 2 - 70 Hz, 0.0099 g/lbf
2 - 184.5 Hz, 0.2058 g/lbf 3 - 110 Hz, 0.0375 g/lbf
3 - 189.5 Hz, 0.1996 g/lbf 4 - 140 Hz, 0.0611 g/lbf
400m 500m

400m
300m

1 300m
Amplitude g/lbf

Amplitude g/lbf
23
200m
200m

100m
100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTR062 1 - 55 Hz, 0.2976 g/lbf PASS


1 - 56.0 Hz, 0.3619 g/lbf 2 - 70 Hz, 0.0761 g/lbf
2 - 54.0 Hz, 0.3149 g/lbf 3 - 110 Hz, 0.0644 g/lbf
3 - 61.5 Hz, 0.1569 g/lbf 4 - 140 Hz, 0.0344 g/lbf
400m 500m
1
2
400m
300m
1
300m
Amplitude g/lbf

Amplitude g/lbf

200m
3
200m

100m
100m 2 3

0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTT062 1 - 55 Hz, 0.0056 g/lbf PASS


1 - 100.0 Hz, 0.8204 g/lbf 2 - 70 Hz, 0.0407 g/lbf
2 - 31.5 Hz, 0.5529 g/lbf 3 - 110 Hz, 0.3409 g/lbf
3 - 93.0 Hz, 0.4154 g/lbf 4 - 140 Hz, 0.1403 g/lbf
1 500m
1
800m 400m
3

600m 2 300m
Amplitude g/lbf

Amplitude g/lbf

3
400m 200m

200m 100m
2
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1144 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCBA063 1 - 55 Hz, 0.0866 g/lbf PASS


1 - 153.0 Hz, 0.3170 g/lbf 2 - 70 Hz, 0.0068 g/lbf
2 - 186.5 Hz, 0.2592 g/lbf 3 - 110 Hz, 0.0233 g/lbf
3 - 197.5 Hz, 0.2097 g/lbf 4 - 140 Hz, 0.0551 g/lbf
400m 500m

1
400m
300m
2
300m
Amplitude g/lbf

Amplitude g/lbf
3
200m
200m

100m
100m 1
3
2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBR063 1 - 55 Hz, 0.7723 g/lbf FAIL


1 - 55.5 Hz, 0.8684 g/lbf 2 - 70 Hz, 0.1230 g/lbf
2 - 54.0 Hz, 0.7411 g/lbf 3 - 110 Hz, 0.0816 g/lbf
3 - 49.0 Hz, 0.2045 g/lbf 4 - 140 Hz, 0.0907 g/lbf
1 500m
1
800m 2 400m

600m 300m
Amplitude g/lbf

Amplitude g/lbf

400m 200m
2
3
200m 100m 3

0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBT063 1 - 55 Hz, 0.0916 g/lbf PASS


1 - 40.5 Hz, 1.7839 g/lbf 2 - 70 Hz, 0.0674 g/lbf
2 - 42.0 Hz, 0.6596 g/lbf 3 - 110 Hz, 0.0536 g/lbf
3 - 185.5 Hz, 0.2491 g/lbf 4 - 140 Hz, 0.0544 g/lbf
2 500m
1

400m
1.5

300m
Amplitude g/lbf

Amplitude g/lbf

1
2 200m

500m 1
3 100m 2
3

0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1145 of 1653


Bump Test_As Found
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 01/19/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCTA063 1 - 55 Hz, 0.0022 g/lbf PASS


1 - 153.0 Hz, 0.5834 g/lbf 2 - 70 Hz, 0.0089 g/lbf
2 - 144.0 Hz, 0.2351 g/lbf 3 - 110 Hz, 0.0355 g/lbf
3 - 146.5 Hz, 0.2250 g/lbf 4 - 140 Hz, 0.1577 g/lbf
800m 500m

1 400m
600m

300m
Amplitude g/lbf

Amplitude g/lbf
400m
200m
23
200m
100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTR063 1 - 55 Hz, 0.0335 g/lbf PASS


1 - 153.0 Hz, 0.2670 g/lbf 2 - 70 Hz, 0.0099 g/lbf
2 - 148.0 Hz, 0.2448 g/lbf 3 - 110 Hz, 0.1560 g/lbf
3 - 112.5 Hz, 0.2214 g/lbf 4 - 140 Hz, 0.0638 g/lbf
400m 500m

400m
300m
1
2
3 300m
Amplitude g/lbf

Amplitude g/lbf

200m
200m
3
100m
100m
1
2
0 0
0 50 100 150 200 50 60 80 100 120 135
Frequency - Hz Frequency - Hz

CEPCTT063 1 - 55 Hz, 0.1414 g/lbf PASS


1 - 153.0 Hz, 0.2073 g/lbf 2 - 70 Hz, 0.0593 g/lbf
2 - 56.0 Hz, 0.1596 g/lbf 3 - 110 Hz, 0.0345 g/lbf
3 - 53.5 Hz, 0.1483 g/lbf 4 - 140 Hz, 0.0229 g/lbf
400m 500m

400m
300m

300m
Amplitude g/lbf

Amplitude g/lbf

1
200m
32 200m
1
100m
100m
2
3

0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1146 of 1653


GE Power Power Services
Upgrade
Winding
End
and
Inspections
324
4.4.4
4.4.4 324 Inspections and End Winding Upgrade
FORM
Part Description:
This TIL provides modifications to the 324 Leads Down (LD) 60Hz fleet for blocking
modifications on the end winding to prevent copper failure in the end windings.
Inspections
Visual
Leads
Flexible
4.4.5
4.4.5 Flexible Leads Visual Inspections
FORM
Part Condition: Good
Part Description:
As part of the TIL 1965 , an inspection into flexible leads and lower leads blocks is also
required. The following steps was completed during this inspection:

Lowers leads blocks were inspected for dusting, loose blocking, broken ties. No signs of the
dusting, loose blocking, broken ties during this inspection.

It was striped the insulation from the Flexible leads , removed putty, completed a thorough
visual inspection of the flexible leads. It was not found any sign of improper assembly , hot
stops for looseness connection or cracks in the flexible lead. Even thought , Customer
required the replacement of the flexible leads for the new flexible leads design.

Initial condition (with fusible tape) Striped fusible tape

270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 1160 of 1653
GE Power Power Services

4.4.5 Flexible Leads Visual Inspections


FORM
Putty removed for visual inspection Putty removed for visual inspection

Clean terminals New flexible leads assembled

Preparation for putty resin application Putty resin on hardware

270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 1161 of 1653
GE Power Power Services

4.4.5 Flexible Leads Visual Inspections


FORM
Flexible leads with silicon tape Flexible leads with glass tape

Flexible leads Painted Flexible leads Painted


NDT
and
4.4.6 Phase Straps Inspections and NDT
Inspections
Straps
Phase
4.4.6
FORM
Part Condition: Good
Part Description:
As part of the TIL 1965, it was advised to inspect for cracks the phase joints B40, B15, B53
and T62 using two methods: phase straps bands using dye penetrant and the stranded bar
locations visually.

It was not finding any sign of cracks visually or by dye penetrant method.

Below you can find pictures and NDT report.

270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 1162 of 1653
GE Power Power Services

4.4.6 Phase Straps Inspections and NDT


FORM
T62 phase strap insulation removed B15 phase strap insulation removed

B53 phase strap insulation removed B40 phase strap insulation removed

NDT performed on phase straps Putty resin on phase straps

270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 1163 of 1653
GE Power Power Services

4.4.6 Phase Straps Inspections and NDT


FORM
Phase strap reinsulated Phase strap reinsulated

Baking of new insulation Phase strap insulation after baking process

270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 1164 of 1653
164-01-21 -PT Estator junction phases
DENTIFICACIÓN:PC-20-01-014 Rev.1
REPORTE END INFORME
164-01-21 -PT

INFORME POR LIQUIDOS PENETRANTES FECHA 3/02/2021
Testing Service Group S.A.C.
PAGINA 01 DE 04
CLIENTE: CONTRATISTA:
PROYECTO:
PARADA DE PLANTA CENTRAL
TERMICA CHILCA UNO - ENGIE FIELDCORE a GE Company TESTING SERVICE GROUP SAC

INFORMACION GENERAL INFORMACION DEL ELEMENTO


MATERIAL: NA
EQUIPO: GENERATOR GE 324
DIAMETRO : NA
ESPESOR: NA
ELEMENTO: Estator junction phases
SERVICIO: NA
CONDICION
SECTOR TURBINA DE VAPOR ACEPTABLE
SUPERFICIAL:
INFORMACION DEL ENSAYO
TIPO DE EXAMINACION: II (visible) METODO: C – Lavable con Solvente
TEMPERATURA DE APLICACIÓN: 10° A 27.3°C PRELIMPIEZA: Manual con desengrasante
PENETRANTE: MAGNAFLUX SKL-SP2 PENETRANT APLICACION DEL PENETRANTE: Brocha
TIEMPO DE PENETRACION: 10 minutos REMOCION DEL PENETRANTE: Trapo Industrial humedecido con solvente
REVELADOR: MAGNAFLUX SKD-S2 DEVELOPER APLICACION DEL REVELADOR: Spray
TIEMPO DE REVELADO: 10 minutos REMOCION DEL REVELADOR: Removedor con trapo Industrial
TSG 601 PROCEDIMIENTO GENERAL DE
NORMA DE EVALUACION: N/A N° DE PROCEDIMIENTO: LIQUIDOS PENETRANTES REV 01

EVALUACION
DIMENSIONES
Identificacion del
Item

No Registra Indicaciones Registra Indicaciones COMENTARIOS


Elemento
ANCHO (mm) LARGO (mm)

1 B15 ---- ---- ---- ---- ----


1 1 8 ----
B40 ---- Se informo a FC para su
2 2 19 10 ----
evaluacion final
3 B53 ---- ---- ---- ---- ----
4 T62 ---- ---- ---- ---- ----
REGISTRO FOTOGRAFICO
ELEMENTO B15

OBSERVACIONES :
1.- Se realizó la Inspección por medio de liquidos penetrantes a cuatro Phase straps
2.- Los Phase straps B15, B53, T62 no presentan indicaciones relevantes
3.- El Phase Straps B40, presentan dos indicaciones, por golpes
4.- Los BEND de los cuatro Phase Straps inspeccionados se encuentran libre de indicaciones

INTERPRETADO QA/QC ENGIE

FECHA: 03/02/21 FECHA: FECHA:

Page 1165 of 1653


164-01-21 -PT Estator junction phases
DENTIFICACIÓN:PC-20-01-014 Rev.1
REPORTE END INFORME
164-01-21 -PT

INFORME POR LIQUIDOS PENETRANTES FECHA 3/02/2021
Testing Service Group S.A.C.
PAGINA 02 DE 04
CLIENTE: CONTRATISTA:
PROYECTO:
PARADA DE PLANTA CENTRAL
TERMICA CHILCA UNO - ENGIE FIELDCORE a GE Company TESTING SERVICE GROUP SAC

INFORMACION GENERAL INFORMACION DEL ELEMENTO


MATERIAL: NA
EQUIPO: GENERATOR GE 324
DIAMETRO : NA
ESPESOR: NA
ELEMENTO: Estator junction phases
SERVICIO: NA
CONDICION
SECTOR TURBINA DE VAPOR ACEPTABLE
SUPERFICIAL:
REGISTRO FOTOGRAFICO
ELEMENTO B40

INTERPRETADO QA/QC ENGIE

FECHA: 03/02/21 FECHA: FECHA:

Page 1166 of 1653


164-01-21 -PT Estator junction phases
DENTIFICACIÓN:PC-20-01-014 Rev.1
REPORTE END INFORME
164-01-21 -PT

INFORME POR LIQUIDOS PENETRANTES FECHA 3/02/2021
Testing Service Group S.A.C.
PAGINA 03 DE 04
CLIENTE: CONTRATISTA:
PROYECTO:
PARADA DE PLANTA CENTRAL
TERMICA CHILCA UNO - ENGIE FIELDCORE a GE Company TESTING SERVICE GROUP SAC

INFORMACION GENERAL INFORMACION DEL ELEMENTO


MATERIAL: NA
EQUIPO: GENERATOR GE 324
DIAMETRO : NA
ESPESOR: NA
ELEMENTO: Estator junction phases
SERVICIO: NA
CONDICION
SECTOR TURBINA DE VAPOR ACEPTABLE
SUPERFICIAL:
REGISTRO FOTOGRAFICO
ELEMENTO B40

ELEMENTO B53

INTERPRETADO QA/QC ENGIE

FECHA: 03/02/21 FECHA: FECHA:

Page 1167 of 1653


164-01-21 -PT Estator junction phases
DENTIFICACIÓN:PC-20-01-014 Rev.1
REPORTE END INFORME
164-01-21 -PT

INFORME POR LIQUIDOS PENETRANTES FECHA 3/02/2021
Testing Service Group S.A.C.
PAGINA 04 DE 04
CLIENTE: CONTRATISTA:
PROYECTO:
PARADA DE PLANTA CENTRAL
TERMICA CHILCA UNO - ENGIE FIELDCORE a GE Company TESTING SERVICE GROUP SAC

INFORMACION GENERAL INFORMACION DEL ELEMENTO


MATERIAL: NA
EQUIPO: GENERATOR GE 324
DIAMETRO : NA
ESPESOR: NA
ELEMENTO: Estator junction phases
SERVICIO: NA
CONDICION
SECTOR TURBINA DE VAPOR ACEPTABLE
SUPERFICIAL:
REGISTRO FOTOGRAFICO
ELEMENTO B62

INTERPRETADO QA/QC ENGIE

FECHA: 03/02/21 FECHA: FECHA:

Page 1168 of 1653


GE Power Power Services
Upgrade
Blocking
Winding
End
4.4.7
4.4.7 End Winding Blocking Upgrade
FORM
Part Description:
Due to recent events within the 324 fleet, GE determined that some units with MVA ratings of
greater than 325 MVA and wet ties are thermally constrained within the connection ring
structure. This lack of thermal compliance in the end winding structure can either lead to
repeated end winding dusting at the phase straps or in some extreme cases can lead to
copper failure at the phase straps or backsets.

This blocking upgrade and modifications on the connection rings and phase straps provides
thermal compliance and resonant frequency isolation to the phase straps and backset on
324 generators.

The following inspection and modifications were made in accordance with the requirements
to compliance with the TIL 1965:

• Backset blocks removal: This unit didn't have backset blocks, so it was not necessary
the removal of this blocks.
• Removal of circumferential blocks between the series loop and phase straps: it was
removed the circumferential blocks between the series loop and phase joints from the 6
phase connections locations at 12 o'clock , 2 o'clock, 4 o'clock , 6 o' clock, 8 o'clock and
10 o'clock respectively.
• Added new radial blocks: I was added new radial blocks between top and bottom
phase straps on all 6 positions.
• Inertance/ bump test was performed before tie the radial blocks. Some phase straps on
tangential or axial position during inertance test to eliminate this high values and
compliance with the TIL it was required by engineer installation of an additional diagonal
blocks. Diagonal blocks were added on the following positions: 2oclock, 4o'clock, 6
o'clock and 10 o'clock.
• Selective connection ring block removal: In compliance with the rules mentioned in the
GE procedure it was removed 2 blocks that are in the picture attached on this report.

Below you can find pictures of the job done.

270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 1169 of 1653
GE Power Power Services

4.4.7 End Winding Blocking Upgrade


FORM
Series caps/Phase Joints blocks removed New blocking - 2 o'clock position

New blocking - 4 o'clock position New blocking - 6 o'clock position

New blocking - 10 o'clock position New blocks after tying - 2 o'clock position

270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 1170 of 1653
GE Power Power Services

4.4.7 End Winding Blocking Upgrade


FORM
New blocks after tying - 4 o'clock position New blocks after tying - 6 o'clock position

New blocks after tying - 10 o'clock position Ties with red eye and floodin resin applied -
10 o'clock position

Ties with red eye and floodin resin applied - Ties with red eye and floodin resin applied -
2 o'clock position 4 o'clock position

270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 1171 of 1653
GE Power Power Services

4.4.7 End Winding Blocking Upgrade


FORM
Ties with red eye and floodin resin applied - Phase joints painted at 6 o'clock
6 o'clock position

Phase joints painted at 2 o'clock End winding Painted -CE side

End winding Painted -TE side

270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 1172 of 1653
GE Power Power Services

4.5 Stator As-Left Electrical Testing


Test
Bump
CATEGORY4.5.1
4.5.1 Bump Test
FORM
Part Condition: Good
Part Description:
As part of the TIL 1965, it was recommended to perform an Endwinding Bump test. This test
was performed by the GE LES (Life Extension Services) team using a certified equipment.
After TIL implementation all phase connections responses were acceptable and found within
limits, see details below.

270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 1173 of 1653
Bump Test_As Left

GE Power Inspection & Life Extension Services


Endwinding Vibration Test Report

Engie Energia Peru Sa


Chilca Uno Power Station
ST1 (290T818)
Endwinding Vibration Test Report

Prepared for: Engie Energia Peru SA


Site: Chilca Uno
Unit No: ST1
Location: Lima, Peru
Generator S/N: 290T818
Turbine S/N: 270T818
Test No: 2
Job No: 10339092#Main 2.1
Date of test: February 10, 2021
Test performed by: Wesley Ihlow

GE Proprietary Information. This document contains proprietary information of the General Electric Company and
may not be used or disclosed to others, except with the written permission of General Electric Company. 1

Page 1174 of 1653


Bump Test_As Left

GE Power Inspection & Life Extension Services


Endwinding Vibration Test Report

EXECUTIVE SUMMARY

This report contains results from a modal impact (bump) test on the end winding series loops and
phase connections of unit ST1 a GE generator S/N 290T818 at the Chilca Uno site in Lima, Peru, on
February 10, 2021. An instrumented hammer was used to excite the generator components while an
accelerometer measured the response. Data was analyzed with a spectrum analyzer in real time and
the frequency response functions, in g/lb were obtained on both the turbine end (TE) and collector
end (CE) series loops and phase connections.

Appendix A Table 1 contain the acceptance criteria.


Appendix B Enclosures 1 through 3 contain the data plotted as a transfer function (Amplitude versus
Frequency).

TEST RESULTS AND SUMMARY OF ANALYSIS


The turbine end series loop axial, radial, and tangential responses were acceptable and found within
limits. Plots of the data are shown in Enclosure 1 of Appendix B.

The collector end series Loop axial, radial, and tangential responses were acceptable and found within
limits. Plots of the data are shown in Enclosure 2 of Appendix B.

The collector end phase connection axial, radial, and tangential responses were acceptable and found
within limits. Plots of the data are shown in Enclosure 3 of Appendix B.

GE Proprietary Information. This document contains proprietary information of the General Electric Company and
may not be used or disclosed to others, except with the written permission of General Electric Company. 2

Page 1175 of 1653


Bump Test_As Left

GE Power Inspection & Life Extension Services


Endwinding Vibration Test Report

CONCLUSIONS AND RECOMMENDATIONS


All limits were within the acceptance criteria established by GE. A copy of this report should be sent
to GE Generator Service Engineering and archived with this unit’s service record.

EQUIPMENT USED

PCB Model 338C04 Accelerometer, S/N 6045 and calibration due date 13AUG2021
PCB Model 086D20 Impact Hammer, S/N 20552 and calibration due date 13AUG2021
OROS OR34 4 Channel PC Based Spectrum Analyzer, S/N 901793 and calibration due date 12AUG2021

TEST OVERVIEW

An end winding vibration “bump” test is performed to determine the fundamental resonant frequency
and associated response value of the individual series loops and phase connections of a generator.
Data related to series loops and phase connections, which exceed current GE criteria, is relayed to GE
Generator Engineering where the results of these tests are analyzed to determine whether additional
support is required. Data related to series loops and phase connections, which appear around 60 and
120 Hz (or 50 and 100 Hz) will be relayed to site personnel for other OEM units.

TERMINOLOGY (SERIES LOOPS AND PHASE CONNECTIONS DATA PLOTS PER LOCATION)
(Appendix B Enclosures 1 through 3)

The left plot for each measurement location and direction is scaled with a frequency range of 0 to 200
Hz. The right plot is scaled for a range of 55 to 140 Hz and includes a horizontal amplitude line
identifying the engineering pass/fail threshold. At the upper left of each trace is a file name identifying
the measurement location and direction. The terminology used for Series Loops and Phase Connection
Data Plots per location is the following:

CEPCBT001.UFF
| | | | | --------------- Bar Number (1 to 72)
| | | | ----------------- A = Axial Direction, R = Radial Direction, T = Tangential Direction
| | | ------------------- B = Bottom Phase Connection; T = Top Phase Connection
| | ---------------------- PC = Phase Connection (No designation for Series Loops)
|-------------------------- CE = Collector End; TE = Turbine End

GE Proprietary Information. This document contains proprietary information of the General Electric Company and
may not be used or disclosed to others, except with the written permission of General Electric Company. 3

Page 1176 of 1653


Bump Test_As Left

GE Power Inspection & Life Extension Services


Endwinding Vibration Test Report

APPENDIX A

Acceptance Criteria

(Test data was compared to the amplitude threshold criteria outlined in table 1)

GE Proprietary Information. This document contains proprietary information of the General Electric Company and
may not be used or disclosed to others, except with the written permission of General Electric Company. 4

Page 1177 of 1653


Bump Test_As Left

GE Power Inspection & Life Extension Services


Endwinding Vibration Test Report

Table 1: Acceptance criteria for GE conventionally-cooled 324 generator resonance testing (2 pole,
60 HZ), Repair Engineering Instruction 503HA422 – 324 End Winding Blocking Upgrades

Series Loop
Measurement Phase Connection Applicable Frequency
Direction Threshold Threshold Range
Axial 0.5 g / lb 0.5 g / lb 55-70 Hz & 110-140 Hz
Radial 0.5 g / lb 0.5 g/ lb 55-70 Hz & 110-140 Hz
Tangential 0.5 g / lb 0.5 g / lb 55-70 Hz & 110-140 Hz

GE Proprietary Information. This document contains proprietary information of the General Electric Company and
may not be used or disclosed to others, except with the written permission of General Electric Company. 5

Page 1178 of 1653


Bump Test_As Left

GE Power Inspection & Life Extension Services


Endwinding Vibration Test Report

APPENDIX B
Test Data Plots
(Amplitude versus Frequency)

GE Proprietary Information. This document contains proprietary information of the General Electric Company and
may not be used or disclosed to others, except with the written permission of General Electric Company. 6

Page 1179 of 1653


Bump Test_As Left

GE Power Inspection & Life Extension Services


Endwinding Vibration Test Report

Enclosure 1
Turbine End Series Loop Frequency Responses
(Amplitude versus Frequency)

GE Proprietary Information. This document contains proprietary information of the General Electric Company and
may not be used or disclosed to others, except with the written permission of General Electric Company. 7

Page 1180 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA001 1 - 55 Hz, 0.0011 g/lbf PASS


1 - 123.0 Hz, 0.0247 g/lbf 2 - 70 Hz, 0.0009 g/lbf
2 - 186.5 Hz, 0.0181 g/lbf 3 - 110 Hz, 0.0090 g/lbf
3 - 190.0 Hz, 0.0171 g/lbf 4 - 140 Hz, 0.0034 g/lbf
40m 500m

400m
30m
1
300m
Amplitude g/lbf

Amplitude g/lbf
20m 23
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER001 1 - 55 Hz, 0.0050 g/lbf PASS


1 - 98.0 Hz, 0.0443 g/lbf 2 - 70 Hz, 0.0034 g/lbf
2 - 66.0 Hz, 0.0419 g/lbf 3 - 110 Hz, 0.0032 g/lbf
3 - 122.0 Hz, 0.0276 g/lbf 4 - 140 Hz, 0.0059 g/lbf
50m 500m
1
2
40m 400m

30m 3 300m
Amplitude g/lbf

Amplitude g/lbf

20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET001 1 - 55 Hz, 0.0028 g/lbf PASS


1 - 187.5 Hz, 0.0518 g/lbf 2 - 70 Hz, 0.0023 g/lbf
2 - 160.0 Hz, 0.0313 g/lbf 3 - 110 Hz, 0.0113 g/lbf
3 - 156.0 Hz, 0.0281 g/lbf 4 - 140 Hz, 0.0138 g/lbf
80m 500m

400m
60m
1
300m
Amplitude g/lbf

Amplitude g/lbf

40m
2
3 200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1181 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA002 1 - 55 Hz, 0.0014 g/lbf PASS


1 - 122.5 Hz, 0.0319 g/lbf 2 - 70 Hz, 0.0014 g/lbf
2 - 186.5 Hz, 0.0226 g/lbf 3 - 110 Hz, 0.0118 g/lbf
3 - 190.0 Hz, 0.0174 g/lbf 4 - 140 Hz, 0.0042 g/lbf
40m 500m

1
400m
30m

2 300m
Amplitude g/lbf

Amplitude g/lbf
20m 3
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER002 1 - 55 Hz, 0.0052 g/lbf PASS


1 - 66.0 Hz, 0.0454 g/lbf 2 - 70 Hz, 0.0032 g/lbf
2 - 98.0 Hz, 0.0399 g/lbf 3 - 110 Hz, 0.0046 g/lbf
3 - 99.5 Hz, 0.0379 g/lbf 4 - 140 Hz, 0.0060 g/lbf
50m 1 500m

2
40m 3 400m

30m 300m
Amplitude g/lbf

Amplitude g/lbf

20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET002 1 - 55 Hz, 0.0026 g/lbf PASS


1 - 187.5 Hz, 0.0498 g/lbf 2 - 70 Hz, 0.0021 g/lbf
2 - 160.0 Hz, 0.0315 g/lbf 3 - 110 Hz, 0.0108 g/lbf
3 - 158.5 Hz, 0.0297 g/lbf 4 - 140 Hz, 0.0125 g/lbf
80m 500m

400m
60m
1
300m
Amplitude g/lbf

Amplitude g/lbf

40m
32 200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1182 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA003 1 - 55 Hz, 0.0013 g/lbf PASS


1 - 122.5 Hz, 0.0313 g/lbf 2 - 70 Hz, 0.0013 g/lbf
2 - 186.0 Hz, 0.0192 g/lbf 3 - 110 Hz, 0.0110 g/lbf
3 - 190.0 Hz, 0.0185 g/lbf 4 - 140 Hz, 0.0037 g/lbf
40m 500m

1 400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf
20m 23

200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER003 1 - 55 Hz, 0.0047 g/lbf PASS


1 - 99.5 Hz, 0.0494 g/lbf 2 - 70 Hz, 0.0034 g/lbf
2 - 66.0 Hz, 0.0489 g/lbf 3 - 110 Hz, 0.0034 g/lbf
3 - 132.0 Hz, 0.0345 g/lbf 4 - 140 Hz, 0.0056 g/lbf
2 1
50m 500m

40m 400m
3

30m 300m
Amplitude g/lbf

Amplitude g/lbf

20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET003 1 - 55 Hz, 0.0041 g/lbf PASS


1 - 187.5 Hz, 0.0682 g/lbf 2 - 70 Hz, 0.0037 g/lbf
2 - 160.0 Hz, 0.0469 g/lbf 3 - 110 Hz, 0.0170 g/lbf
3 - 155.5 Hz, 0.0420 g/lbf 4 - 140 Hz, 0.0206 g/lbf
200m 500m

400m

300m
Amplitude g/lbf

Amplitude g/lbf

100m
1 200m

32
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1183 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA004 1 - 55 Hz, 0.0014 g/lbf PASS


1 - 122.5 Hz, 0.0325 g/lbf 2 - 70 Hz, 0.0016 g/lbf
2 - 190.0 Hz, 0.0204 g/lbf 3 - 110 Hz, 0.0117 g/lbf
3 - 155.5 Hz, 0.0149 g/lbf 4 - 140 Hz, 0.0042 g/lbf
40m 500m

1
400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf
2
20m
3 200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER004 1 - 55 Hz, 0.0053 g/lbf PASS


1 - 99.5 Hz, 0.0621 g/lbf 2 - 70 Hz, 0.0032 g/lbf
2 - 66.0 Hz, 0.0499 g/lbf 3 - 110 Hz, 0.0038 g/lbf
3 - 132.0 Hz, 0.0367 g/lbf 4 - 140 Hz, 0.0053 g/lbf
80m 500m

1 400m
60m
2
300m
Amplitude g/lbf

Amplitude g/lbf

40m 3
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET004 1 - 55 Hz, 0.0025 g/lbf PASS


1 - 187.0 Hz, 0.0390 g/lbf 2 - 70 Hz, 0.0015 g/lbf
2 - 160.0 Hz, 0.0267 g/lbf 3 - 110 Hz, 0.0097 g/lbf
3 - 164.0 Hz, 0.0248 g/lbf 4 - 140 Hz, 0.0103 g/lbf
80m 500m

400m
60m

300m
Amplitude g/lbf

Amplitude g/lbf

1
40m
23 200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1184 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA005 1 - 55 Hz, 0.0013 g/lbf PASS


1 - 122.5 Hz, 0.0301 g/lbf 2 - 70 Hz, 0.0017 g/lbf
2 - 188.0 Hz, 0.0217 g/lbf 3 - 110 Hz, 0.0114 g/lbf
3 - 155.5 Hz, 0.0127 g/lbf 4 - 140 Hz, 0.0050 g/lbf
40m 500m

1 400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf
2
20m
200m
3
10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER005 1 - 55 Hz, 0.0044 g/lbf PASS


1 - 99.5 Hz, 0.0529 g/lbf 2 - 70 Hz, 0.0023 g/lbf
2 - 66.0 Hz, 0.0385 g/lbf 3 - 110 Hz, 0.0041 g/lbf
3 - 134.0 Hz, 0.0371 g/lbf 4 - 140 Hz, 0.0049 g/lbf
80m 500m

400m
60m
1
300m
Amplitude g/lbf

Amplitude g/lbf

40m 2 3
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET005 1 - 55 Hz, 0.0020 g/lbf PASS


1 - 187.0 Hz, 0.0456 g/lbf 2 - 70 Hz, 0.0012 g/lbf
2 - 160.0 Hz, 0.0271 g/lbf 3 - 110 Hz, 0.0085 g/lbf
3 - 154.5 Hz, 0.0214 g/lbf 4 - 140 Hz, 0.0093 g/lbf
80m 500m

400m
60m

1 300m
Amplitude g/lbf

Amplitude g/lbf

40m
2 200m
3
20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1185 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA006 1 - 55 Hz, 0.0014 g/lbf PASS


1 - 122.5 Hz, 0.0349 g/lbf 2 - 70 Hz, 0.0017 g/lbf
2 - 186.5 Hz, 0.0233 g/lbf 3 - 110 Hz, 0.0132 g/lbf
3 - 155.5 Hz, 0.0184 g/lbf 4 - 140 Hz, 0.0053 g/lbf
40m 500m
1
400m
30m
2 300m
Amplitude g/lbf

Amplitude g/lbf
20m 3
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER006 1 - 55 Hz, 0.0044 g/lbf PASS


1 - 99.5 Hz, 0.0515 g/lbf 2 - 70 Hz, 0.0022 g/lbf
2 - 134.0 Hz, 0.0432 g/lbf 3 - 110 Hz, 0.0047 g/lbf
3 - 66.0 Hz, 0.0372 g/lbf 4 - 140 Hz, 0.0051 g/lbf
80m 500m

400m
60m
1
300m
Amplitude g/lbf

Amplitude g/lbf

2
40m 3
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET006 1 - 55 Hz, 0.0033 g/lbf PASS


1 - 186.5 Hz, 0.0826 g/lbf 2 - 70 Hz, 0.0024 g/lbf
2 - 159.5 Hz, 0.0502 g/lbf 3 - 110 Hz, 0.0143 g/lbf
3 - 154.5 Hz, 0.0376 g/lbf 4 - 140 Hz, 0.0165 g/lbf
200m 500m

400m

300m
Amplitude g/lbf

Amplitude g/lbf

100m
1
200m
2
3
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1186 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA007 1 - 55 Hz, 0.0016 g/lbf PASS


1 - 187.0 Hz, 0.0295 g/lbf 2 - 70 Hz, 0.0019 g/lbf
2 - 122.5 Hz, 0.0288 g/lbf 3 - 110 Hz, 0.0118 g/lbf
3 - 154.5 Hz, 0.0150 g/lbf 4 - 140 Hz, 0.0069 g/lbf
40m 500m

1 400m
30m 2

300m
Amplitude g/lbf

Amplitude g/lbf
20m
3 200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER007 1 - 55 Hz, 0.0045 g/lbf PASS


1 - 187.5 Hz, 0.0602 g/lbf 2 - 70 Hz, 0.0019 g/lbf
2 - 134.0 Hz, 0.0571 g/lbf 3 - 110 Hz, 0.0067 g/lbf
3 - 163.5 Hz, 0.0428 g/lbf 4 - 140 Hz, 0.0061 g/lbf
80m 500m

1 400m
60m 2

300m
Amplitude g/lbf

Amplitude g/lbf

3
40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET007 1 - 55 Hz, 0.0042 g/lbf PASS


1 - 186.0 Hz, 0.0794 g/lbf 2 - 70 Hz, 0.0041 g/lbf
2 - 159.5 Hz, 0.0517 g/lbf 3 - 110 Hz, 0.0166 g/lbf
3 - 154.5 Hz, 0.0420 g/lbf 4 - 140 Hz, 0.0237 g/lbf
200m 500m

400m

300m
Amplitude g/lbf

Amplitude g/lbf

100m
1
200m
2
3
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1187 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA008 1 - 55 Hz, 0.0012 g/lbf PASS


1 - 122.5 Hz, 0.0285 g/lbf 2 - 70 Hz, 0.0016 g/lbf
2 - 187.0 Hz, 0.0280 g/lbf 3 - 110 Hz, 0.0116 g/lbf
3 - 154.5 Hz, 0.0141 g/lbf 4 - 140 Hz, 0.0055 g/lbf
40m 500m

400m
30m 1 2

300m
Amplitude g/lbf

Amplitude g/lbf
20m
3 200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER008 1 - 55 Hz, 0.0040 g/lbf PASS


1 - 187.5 Hz, 0.0644 g/lbf 2 - 70 Hz, 0.0022 g/lbf
2 - 134.0 Hz, 0.0524 g/lbf 3 - 110 Hz, 0.0060 g/lbf
3 - 163.5 Hz, 0.0500 g/lbf 4 - 140 Hz, 0.0073 g/lbf
80m 500m

1
400m
60m
2
3
300m
Amplitude g/lbf

Amplitude g/lbf

40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET008 1 - 55 Hz, 0.0029 g/lbf PASS


1 - 186.0 Hz, 0.0475 g/lbf 2 - 70 Hz, 0.0023 g/lbf
2 - 193.5 Hz, 0.0460 g/lbf 3 - 110 Hz, 0.0111 g/lbf
3 - 160.0 Hz, 0.0349 g/lbf 4 - 140 Hz, 0.0141 g/lbf
80m 500m

400m
60m
1 2
300m
Amplitude g/lbf

Amplitude g/lbf

40m 3
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1188 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA009 1 - 55 Hz, 0.0013 g/lbf PASS


1 - 187.0 Hz, 0.0287 g/lbf 2 - 70 Hz, 0.0017 g/lbf
2 - 122.5 Hz, 0.0282 g/lbf 3 - 110 Hz, 0.0116 g/lbf
3 - 154.5 Hz, 0.0155 g/lbf 4 - 140 Hz, 0.0056 g/lbf
40m 500m

400m
30m 2 1

300m
Amplitude g/lbf

Amplitude g/lbf
20m
3
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER009 1 - 55 Hz, 0.0037 g/lbf PASS


1 - 186.5 Hz, 0.0552 g/lbf 2 - 70 Hz, 0.0024 g/lbf
2 - 98.0 Hz, 0.0488 g/lbf 3 - 110 Hz, 0.0047 g/lbf
3 - 164.0 Hz, 0.0468 g/lbf 4 - 140 Hz, 0.0072 g/lbf
80m 500m

400m
60m 1
2 3
300m
Amplitude g/lbf

Amplitude g/lbf

40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET009 1 - 55 Hz, 0.0029 g/lbf PASS


1 - 190.5 Hz, 0.0491 g/lbf 2 - 70 Hz, 0.0020 g/lbf
2 - 192.5 Hz, 0.0480 g/lbf 3 - 110 Hz, 0.0108 g/lbf
3 - 158.5 Hz, 0.0339 g/lbf 4 - 140 Hz, 0.0125 g/lbf
80m 500m

400m
60m
12
300m
Amplitude g/lbf

Amplitude g/lbf

40m 3
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1189 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA010 1 - 55 Hz, 0.0011 g/lbf PASS


1 - 122.5 Hz, 0.0207 g/lbf 2 - 70 Hz, 0.0012 g/lbf
2 - 187.5 Hz, 0.0165 g/lbf 3 - 110 Hz, 0.0084 g/lbf
3 - 154.0 Hz, 0.0111 g/lbf 4 - 140 Hz, 0.0042 g/lbf
40m 500m

400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf
1
20m
2
200m
3
10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER010 1 - 55 Hz, 0.0034 g/lbf PASS


1 - 98.0 Hz, 0.0484 g/lbf 2 - 70 Hz, 0.0022 g/lbf
2 - 186.5 Hz, 0.0408 g/lbf 3 - 110 Hz, 0.0048 g/lbf
3 - 132.0 Hz, 0.0350 g/lbf 4 - 140 Hz, 0.0057 g/lbf
50m 1
500m
2
40m 400m
3

30m 300m
Amplitude g/lbf

Amplitude g/lbf

20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET010 1 - 55 Hz, 0.0032 g/lbf PASS


1 - 190.5 Hz, 0.0711 g/lbf 2 - 70 Hz, 0.0032 g/lbf
2 - 154.0 Hz, 0.0342 g/lbf 3 - 110 Hz, 0.0125 g/lbf
3 - 158.0 Hz, 0.0338 g/lbf 4 - 140 Hz, 0.0180 g/lbf
80m 500m
1

400m
60m

300m
Amplitude g/lbf

Amplitude g/lbf

40m 23
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1190 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA011 1 - 55 Hz, 0.0009 g/lbf PASS


1 - 122.5 Hz, 0.0199 g/lbf 2 - 70 Hz, 0.0012 g/lbf
2 - 187.0 Hz, 0.0155 g/lbf 3 - 110 Hz, 0.0084 g/lbf
3 - 154.5 Hz, 0.0111 g/lbf 1 4 - 140 Hz, 0.0040 g/lbf
20m 500m

2 400m
15m

3 300m
Amplitude g/lbf

Amplitude g/lbf
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER011 1 - 55 Hz, 0.0032 g/lbf PASS


1 - 98.0 Hz, 0.0449 g/lbf 2 - 70 Hz, 0.0021 g/lbf
2 - 65.5 Hz, 0.0360 g/lbf 3 - 110 Hz, 0.0047 g/lbf
3 - 132.0 Hz, 0.0326 g/lbf 4 - 140 Hz, 0.0027 g/lbf
50m 500m
1

40m 400m
2
3
30m 300m
Amplitude g/lbf

Amplitude g/lbf

20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET011 1 - 55 Hz, 0.0022 g/lbf PASS


1 - 191.0 Hz, 0.0449 g/lbf 2 - 70 Hz, 0.0019 g/lbf
2 - 154.5 Hz, 0.0236 g/lbf 3 - 110 Hz, 0.0084 g/lbf
3 - 158.0 Hz, 0.0232 g/lbf 4 - 140 Hz, 0.0109 g/lbf
50m 500m
1

40m 400m

30m 300m
Amplitude g/lbf

Amplitude g/lbf

23
20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1191 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA012 1 - 55 Hz, 0.0010 g/lbf PASS


1 - 122.5 Hz, 0.0201 g/lbf 2 - 70 Hz, 0.0013 g/lbf
2 - 189.5 Hz, 0.0167 g/lbf 3 - 110 Hz, 0.0089 g/lbf
3 - 154.5 Hz, 0.0140 g/lbf 4 - 140 Hz, 0.0042 g/lbf
40m 500m

400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf
1
20m
2
3 200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER012 1 - 55 Hz, 0.0031 g/lbf PASS


1 - 98.0 Hz, 0.0385 g/lbf 2 - 70 Hz, 0.0020 g/lbf
2 - 65.5 Hz, 0.0362 g/lbf 3 - 110 Hz, 0.0062 g/lbf
3 - 132.0 Hz, 0.0299 g/lbf 4 - 140 Hz, 0.0031 g/lbf
40m 1 500m
2

3 400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf

20m
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET012 1 - 55 Hz, 0.0038 g/lbf PASS


1 - 191.0 Hz, 0.0725 g/lbf 2 - 70 Hz, 0.0039 g/lbf
2 - 187.5 Hz, 0.0674 g/lbf 3 - 110 Hz, 0.0148 g/lbf
3 - 154.0 Hz, 0.0416 g/lbf 4 - 140 Hz, 0.0218 g/lbf
100m 500m

1 400m
2
300m
Amplitude g/lbf

Amplitude g/lbf

50m
3
200m

100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1192 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA013 1 - 55 Hz, 0.0009 g/lbf PASS


1 - 122.5 Hz, 0.0209 g/lbf 2 - 70 Hz, 0.0013 g/lbf
2 - 189.5 Hz, 0.0182 g/lbf 3 - 110 Hz, 0.0093 g/lbf
3 - 154.5 Hz, 0.0170 g/lbf 4 - 140 Hz, 0.0038 g/lbf
40m 500m

400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf
1
20m 2
3
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER013 1 - 55 Hz, 0.0032 g/lbf PASS


1 - 65.5 Hz, 0.0394 g/lbf 2 - 70 Hz, 0.0026 g/lbf
2 - 98.0 Hz, 0.0364 g/lbf 3 - 110 Hz, 0.0051 g/lbf
3 - 99.5 Hz, 0.0325 g/lbf 4 - 140 Hz, 0.0042 g/lbf
50m 500m

1
40m 2 400m
3
30m 300m
Amplitude g/lbf

Amplitude g/lbf

20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET013 1 - 55 Hz, 0.0015 g/lbf PASS


1 - 192.5 Hz, 0.0250 g/lbf 2 - 70 Hz, 0.0011 g/lbf
2 - 190.0 Hz, 0.0238 g/lbf 3 - 110 Hz, 0.0059 g/lbf
3 - 154.5 Hz, 0.0176 g/lbf 4 - 140 Hz, 0.0067 g/lbf
40m 500m

400m
30m
1
2
300m
Amplitude g/lbf

Amplitude g/lbf

20m 3
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1193 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA014 1 - 55 Hz, 0.0010 g/lbf PASS


1 - 122.5 Hz, 0.0206 g/lbf 2 - 70 Hz, 0.0013 g/lbf
2 - 154.5 Hz, 0.0200 g/lbf 3 - 110 Hz, 0.0097 g/lbf
3 - 189.5 Hz, 0.0192 g/lbf 4 - 140 Hz, 0.0039 g/lbf
40m 500m

400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf
1 2
20m 3

200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER014 1 - 55 Hz, 0.0031 g/lbf PASS


1 - 99.5 Hz, 0.0373 g/lbf 2 - 70 Hz, 0.0023 g/lbf
2 - 65.5 Hz, 0.0341 g/lbf 3 - 110 Hz, 0.0057 g/lbf
3 - 98.0 Hz, 0.0308 g/lbf 4 - 140 Hz, 0.0042 g/lbf
40m 1 500m
2
3 400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf

20m
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET014 1 - 55 Hz, 0.0022 g/lbf PASS


1 - 187.5 Hz, 0.0349 g/lbf 2 - 70 Hz, 0.0013 g/lbf
2 - 192.5 Hz, 0.0324 g/lbf 3 - 110 Hz, 0.0080 g/lbf
3 - 154.5 Hz, 0.0244 g/lbf 4 - 140 Hz, 0.0095 g/lbf
80m 500m

400m
60m

300m
Amplitude g/lbf

Amplitude g/lbf

40m 1
2
200m
3
20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1194 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA015 1 - 55 Hz, 0.0011 g/lbf PASS


1 - 122.5 Hz, 0.0222 g/lbf 2 - 70 Hz, 0.0016 g/lbf
2 - 154.5 Hz, 0.0215 g/lbf 3 - 110 Hz, 0.0106 g/lbf
3 - 188.0 Hz, 0.0210 g/lbf 4 - 140 Hz, 0.0047 g/lbf
40m 500m

400m
30m

1 300m
Amplitude g/lbf

Amplitude g/lbf
2 3
20m
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER015 1 - 55 Hz, 0.0033 g/lbf PASS


1 - 99.5 Hz, 0.0474 g/lbf 2 - 70 Hz, 0.0022 g/lbf
2 - 134.0 Hz, 0.0341 g/lbf 3 - 110 Hz, 0.0053 g/lbf
3 - 164.0 Hz, 0.0319 g/lbf 4 - 140 Hz, 0.0042 g/lbf
50m 1 500m

40m 400m
2
3
30m 300m
Amplitude g/lbf

Amplitude g/lbf

20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET015 1 - 55 Hz, 0.0026 g/lbf PASS


1 - 187.5 Hz, 0.0450 g/lbf 2 - 70 Hz, 0.0019 g/lbf
2 - 192.5 Hz, 0.0379 g/lbf 3 - 110 Hz, 0.0097 g/lbf
3 - 154.5 Hz, 0.0272 g/lbf 4 - 140 Hz, 0.0127 g/lbf
80m 500m

400m
60m

1 300m
Amplitude g/lbf

Amplitude g/lbf

40m 2

3 200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1195 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA016 1 - 55 Hz, 0.0012 g/lbf PASS


1 - 123.0 Hz, 0.0240 g/lbf 2 - 70 Hz, 0.0018 g/lbf
2 - 187.5 Hz, 0.0232 g/lbf 3 - 110 Hz, 0.0113 g/lbf
3 - 154.5 Hz, 0.0211 g/lbf 4 - 140 Hz, 0.0054 g/lbf
40m 500m

400m
30m
1 2 300m
Amplitude g/lbf

Amplitude g/lbf
3
20m
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER016 1 - 55 Hz, 0.0033 g/lbf PASS


1 - 99.5 Hz, 0.0520 g/lbf 2 - 70 Hz, 0.0020 g/lbf
2 - 134.0 Hz, 0.0369 g/lbf 3 - 110 Hz, 0.0054 g/lbf
3 - 163.5 Hz, 0.0349 g/lbf 4 - 140 Hz, 0.0034 g/lbf
80m 500m

400m
60m
1
300m
Amplitude g/lbf

Amplitude g/lbf

40m 2 3
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET016 1 - 55 Hz, 0.0022 g/lbf PASS


1 - 188.0 Hz, 0.0357 g/lbf 2 - 70 Hz, 0.0013 g/lbf
2 - 193.5 Hz, 0.0330 g/lbf 3 - 110 Hz, 0.0071 g/lbf
3 - 155.5 Hz, 0.0202 g/lbf 4 - 140 Hz, 0.0093 g/lbf
50m 500m

40m 400m
1
2
30m 300m
Amplitude g/lbf

Amplitude g/lbf

3
20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1196 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA017 1 - 55 Hz, 0.0010 g/lbf PASS


1 - 123.0 Hz, 0.0224 g/lbf 2 - 70 Hz, 0.0014 g/lbf
2 - 187.5 Hz, 0.0192 g/lbf 3 - 110 Hz, 0.0090 g/lbf
3 - 154.5 Hz, 0.0144 g/lbf 4 - 140 Hz, 0.0041 g/lbf
40m 500m

400m
30m

1 300m
Amplitude g/lbf

Amplitude g/lbf
20m 2

3 200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER017 1 - 55 Hz, 0.0034 g/lbf PASS


1 - 99.5 Hz, 0.0527 g/lbf 2 - 70 Hz, 0.0021 g/lbf
2 - 134.0 Hz, 0.0353 g/lbf 3 - 110 Hz, 0.0059 g/lbf
3 - 66.0 Hz, 0.0305 g/lbf 4 - 140 Hz, 0.0046 g/lbf
80m 500m

400m
60m
1
300m
Amplitude g/lbf

Amplitude g/lbf

40m 2
3
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET017 1 - 55 Hz, 0.0030 g/lbf PASS


1 - 188.5 Hz, 0.0543 g/lbf 2 - 70 Hz, 0.0017 g/lbf
2 - 155.5 Hz, 0.0278 g/lbf 3 - 110 Hz, 0.0099 g/lbf
3 - 159.5 Hz, 0.0277 g/lbf 4 - 140 Hz, 0.0133 g/lbf
80m 500m

400m
60m 1

300m
Amplitude g/lbf

Amplitude g/lbf

40m
23 200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1197 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA018 1 - 55 Hz, 0.0012 g/lbf PASS


1 - 123.0 Hz, 0.0254 g/lbf 2 - 70 Hz, 0.0018 g/lbf
2 - 187.0 Hz, 0.0214 g/lbf 3 - 110 Hz, 0.0110 g/lbf
3 - 154.5 Hz, 0.0162 g/lbf 4 - 140 Hz, 0.0053 g/lbf
40m 500m

400m
30m
1
300m
Amplitude g/lbf

Amplitude g/lbf
2
20m
3
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER018 1 - 55 Hz, 0.0034 g/lbf PASS


1 - 99.5 Hz, 0.0464 g/lbf 2 - 70 Hz, 0.0022 g/lbf
2 - 160.5 Hz, 0.0341 g/lbf 3 - 110 Hz, 0.0052 g/lbf
3 - 66.0 Hz, 0.0341 g/lbf 4 - 140 Hz, 0.0042 g/lbf
50m 1 500m

40m 400m
3 2

30m 300m
Amplitude g/lbf

Amplitude g/lbf

20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET018 1 - 55 Hz, 0.0025 g/lbf PASS


1 - 190.0 Hz, 0.0513 g/lbf 2 - 70 Hz, 0.0021 g/lbf
2 - 193.5 Hz, 0.0473 g/lbf 3 - 110 Hz, 0.0094 g/lbf
3 - 159.5 Hz, 0.0266 g/lbf 4 - 140 Hz, 0.0126 g/lbf
80m 500m

400m
60m
1
2
300m
Amplitude g/lbf

Amplitude g/lbf

40m

3 200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1198 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA019 1 - 55 Hz, 0.0011 g/lbf PASS


1 - 123.0 Hz, 0.0240 g/lbf 2 - 70 Hz, 0.0014 g/lbf
2 - 187.0 Hz, 0.0171 g/lbf 3 - 110 Hz, 0.0087 g/lbf
3 - 155.5 Hz, 0.0117 g/lbf 4 - 140 Hz, 0.0036 g/lbf
40m 500m

400m
30m
1
300m
Amplitude g/lbf

Amplitude g/lbf
20m 2
200m
3
10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER019 1 - 55 Hz, 0.0037 g/lbf PASS


1 - 160.5 Hz, 0.0591 g/lbf 2 - 70 Hz, 0.0022 g/lbf
2 - 132.0 Hz, 0.0513 g/lbf 3 - 110 Hz, 0.0056 g/lbf
3 - 98.0 Hz, 0.0409 g/lbf 4 - 140 Hz, 0.0042 g/lbf
80m 500m

1 400m
60m
2
300m
Amplitude g/lbf

Amplitude g/lbf

3
40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET019 1 - 55 Hz, 0.0031 g/lbf PASS


1 - 190.5 Hz, 0.0875 g/lbf 2 - 70 Hz, 0.0023 g/lbf
2 - 193.0 Hz, 0.0855 g/lbf 3 - 110 Hz, 0.0124 g/lbf
3 - 159.5 Hz, 0.0357 g/lbf 4 - 140 Hz, 0.0163 g/lbf
100m 500m
12
400m

300m
Amplitude g/lbf

Amplitude g/lbf

50m
3 200m

100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1199 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA020 1 - 55 Hz, 0.0011 g/lbf PASS


1 - 123.0 Hz, 0.0270 g/lbf 2 - 70 Hz, 0.0017 g/lbf
2 - 187.0 Hz, 0.0172 g/lbf 3 - 110 Hz, 0.0107 g/lbf
3 - 155.5 Hz, 0.0163 g/lbf 4 - 140 Hz, 0.0042 g/lbf
40m 500m

400m
30m 1
300m
Amplitude g/lbf

Amplitude g/lbf
20m 2
3
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER020 1 - 55 Hz, 0.0036 g/lbf PASS


1 - 160.5 Hz, 0.0589 g/lbf 2 - 70 Hz, 0.0026 g/lbf
2 - 132.0 Hz, 0.0541 g/lbf 3 - 110 Hz, 0.0038 g/lbf
3 - 98.0 Hz, 0.0490 g/lbf 4 - 140 Hz, 0.0043 g/lbf
80m 500m

1 400m
60m 2
3
300m
Amplitude g/lbf

Amplitude g/lbf

40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET020 1 - 55 Hz, 0.0040 g/lbf PASS


1 - 192.5 Hz, 0.1217 g/lbf 2 - 70 Hz, 0.0029 g/lbf
2 - 190.5 Hz, 0.1199 g/lbf 3 - 110 Hz, 0.0161 g/lbf
3 - 159.5 Hz, 0.0490 g/lbf 4 - 140 Hz, 0.0202 g/lbf
200m 500m

400m

21
300m
Amplitude g/lbf

Amplitude g/lbf

100m
200m
3
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1200 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA021 1 - 55 Hz, 0.0013 g/lbf PASS


1 - 123.0 Hz, 0.0247 g/lbf 2 - 70 Hz, 0.0015 g/lbf
2 - 187.0 Hz, 0.0194 g/lbf 3 - 110 Hz, 0.0089 g/lbf
3 - 155.5 Hz, 0.0147 g/lbf 4 - 140 Hz, 0.0042 g/lbf
40m 500m

400m
30m
1
300m
Amplitude g/lbf

Amplitude g/lbf
20m 2
3 200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER021 1 - 55 Hz, 0.0036 g/lbf PASS


1 - 98.0 Hz, 0.0555 g/lbf 2 - 70 Hz, 0.0024 g/lbf
2 - 132.0 Hz, 0.0488 g/lbf 3 - 110 Hz, 0.0039 g/lbf
3 - 160.5 Hz, 0.0476 g/lbf 4 - 140 Hz, 0.0035 g/lbf
80m 500m

400m
60m 1
2 3
300m
Amplitude g/lbf

Amplitude g/lbf

40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET021 1 - 55 Hz, 0.0037 g/lbf PASS


1 - 190.5 Hz, 0.1135 g/lbf 2 - 70 Hz, 0.0036 g/lbf
2 - 159.5 Hz, 0.0421 g/lbf 3 - 110 Hz, 0.0165 g/lbf
3 - 154.5 Hz, 0.0408 g/lbf 4 - 140 Hz, 0.0220 g/lbf
200m 500m

400m

1 300m
Amplitude g/lbf

Amplitude g/lbf

100m
200m

32
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1201 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA022 1 - 55 Hz, 0.0017 g/lbf PASS


1 - 123.0 Hz, 0.0230 g/lbf 2 - 70 Hz, 0.0017 g/lbf
2 - 187.0 Hz, 0.0208 g/lbf 3 - 110 Hz, 0.0088 g/lbf
3 - 155.5 Hz, 0.0149 g/lbf 4 - 140 Hz, 0.0055 g/lbf
40m 500m

400m
30m

1 300m
Amplitude g/lbf

Amplitude g/lbf
2
20m
3 200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER022 1 - 55 Hz, 0.0041 g/lbf PASS


1 - 98.0 Hz, 0.0620 g/lbf 2 - 70 Hz, 0.0022 g/lbf
2 - 132.0 Hz, 0.0443 g/lbf 3 - 110 Hz, 0.0042 g/lbf
3 - 66.0 Hz, 0.0426 g/lbf 4 - 140 Hz, 0.0034 g/lbf
80m 500m

1 400m
60m

2 300m
Amplitude g/lbf

Amplitude g/lbf

3
40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET022 1 - 55 Hz, 0.0046 g/lbf PASS


1 - 192.0 Hz, 0.1344 g/lbf 2 - 70 Hz, 0.0049 g/lbf
2 - 187.0 Hz, 0.1124 g/lbf 3 - 110 Hz, 0.0207 g/lbf
3 - 158.0 Hz, 0.0570 g/lbf 4 - 140 Hz, 0.0312 g/lbf
200m 500m

400m
1
2 300m
Amplitude g/lbf

Amplitude g/lbf

100m
200m
3

100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1202 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA023 1 - 55 Hz, 0.0013 g/lbf PASS


1 - 123.0 Hz, 0.0243 g/lbf 2 - 70 Hz, 0.0016 g/lbf
2 - 186.5 Hz, 0.0170 g/lbf 3 - 110 Hz, 0.0095 g/lbf
3 - 155.5 Hz, 0.0155 g/lbf 4 - 140 Hz, 0.0045 g/lbf
40m 500m

400m
30m
1
300m
Amplitude g/lbf

Amplitude g/lbf
20m
2
3
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER023 1 - 55 Hz, 0.0042 g/lbf PASS


1 - 98.0 Hz, 0.0591 g/lbf 2 - 70 Hz, 0.0022 g/lbf
2 - 186.0 Hz, 0.0489 g/lbf 3 - 110 Hz, 0.0044 g/lbf
3 - 134.0 Hz, 0.0478 g/lbf 4 - 140 Hz, 0.0048 g/lbf
80m 500m

1 400m
60m
3 2
300m
Amplitude g/lbf

Amplitude g/lbf

40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET023 1 - 55 Hz, 0.0033 g/lbf PASS


1 - 192.0 Hz, 0.0864 g/lbf 2 - 70 Hz, 0.0033 g/lbf
2 - 186.5 Hz, 0.0745 g/lbf 3 - 110 Hz, 0.0152 g/lbf
3 - 154.0 Hz, 0.0392 g/lbf 4 - 140 Hz, 0.0211 g/lbf
100m 500m
1
2 400m

300m
Amplitude g/lbf

Amplitude g/lbf

50m
3
200m

100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1203 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA024 1 - 55 Hz, 0.0014 g/lbf PASS


1 - 123.0 Hz, 0.0226 g/lbf 2 - 70 Hz, 0.0014 g/lbf
2 - 189.5 Hz, 0.0157 g/lbf 3 - 110 Hz, 0.0091 g/lbf
3 - 186.5 Hz, 0.0154 g/lbf 4 - 140 Hz, 0.0041 g/lbf
40m 500m

400m
30m

1 300m
Amplitude g/lbf

Amplitude g/lbf
20m
32 200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER024 1 - 55 Hz, 0.0041 g/lbf PASS


1 - 134.0 Hz, 0.0561 g/lbf 2 - 70 Hz, 0.0023 g/lbf
2 - 98.0 Hz, 0.0541 g/lbf 3 - 110 Hz, 0.0032 g/lbf
3 - 186.5 Hz, 0.0428 g/lbf 4 - 140 Hz, 0.0058 g/lbf
80m 500m

400m
60m 2 1

300m
Amplitude g/lbf

Amplitude g/lbf

3
40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET024 1 - 55 Hz, 0.0028 g/lbf PASS


1 - 192.5 Hz, 0.0647 g/lbf 2 - 70 Hz, 0.0019 g/lbf
2 - 186.5 Hz, 0.0594 g/lbf 3 - 110 Hz, 0.0120 g/lbf
3 - 154.0 Hz, 0.0318 g/lbf 4 - 140 Hz, 0.0153 g/lbf
80m 500m

1
2 400m
60m

300m
Amplitude g/lbf

Amplitude g/lbf

40m
3
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1204 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA025 1 - 55 Hz, 0.0011 g/lbf PASS


1 - 123.0 Hz, 0.0206 g/lbf 2 - 70 Hz, 0.0013 g/lbf
2 - 190.0 Hz, 0.0153 g/lbf 3 - 110 Hz, 0.0084 g/lbf
3 - 125.0 Hz, 0.0140 g/lbf 4 - 140 Hz, 0.0034 g/lbf
40m 500m

400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf
1
20m
2
3 200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER025 1 - 55 Hz, 0.0039 g/lbf PASS


1 - 134.0 Hz, 0.0520 g/lbf 2 - 70 Hz, 0.0025 g/lbf
2 - 98.0 Hz, 0.0385 g/lbf 3 - 110 Hz, 0.0026 g/lbf
3 - 191.0 Hz, 0.0330 g/lbf 4 - 140 Hz, 0.0064 g/lbf
80m 500m

400m
60m
1
300m
Amplitude g/lbf

Amplitude g/lbf

40m 2
3
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET025 1 - 55 Hz, 0.0026 g/lbf PASS


1 - 185.5 Hz, 0.0528 g/lbf 2 - 70 Hz, 0.0015 g/lbf
2 - 192.5 Hz, 0.0428 g/lbf 3 - 110 Hz, 0.0104 g/lbf
3 - 154.0 Hz, 0.0276 g/lbf 4 - 140 Hz, 0.0135 g/lbf
80m 500m

400m
60m
1
300m
Amplitude g/lbf

Amplitude g/lbf

2
40m
3 200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1205 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA026 1 - 55 Hz, 0.0010 g/lbf PASS


1 - 122.5 Hz, 0.0199 g/lbf 2 - 70 Hz, 0.0013 g/lbf
2 - 189.5 Hz, 0.0164 g/lbf 3 - 110 Hz, 0.0086 g/lbf
3 - 125.0 Hz, 0.0143 g/lbf 1 4 - 140 Hz, 0.0036 g/lbf
20m 500m
2
400m
15m 3

300m
Amplitude g/lbf

Amplitude g/lbf
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER026 1 - 55 Hz, 0.0045 g/lbf PASS


1 - 134.0 Hz, 0.0543 g/lbf 2 - 70 Hz, 0.0023 g/lbf
2 - 99.5 Hz, 0.0483 g/lbf 3 - 110 Hz, 0.0034 g/lbf
3 - 160.0 Hz, 0.0420 g/lbf 4 - 140 Hz, 0.0066 g/lbf
80m 500m

400m
60m 1
2
300m
Amplitude g/lbf

Amplitude g/lbf

3
40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET026 1 - 55 Hz, 0.0035 g/lbf PASS


1 - 184.5 Hz, 0.0853 g/lbf 2 - 70 Hz, 0.0024 g/lbf
2 - 192.0 Hz, 0.0467 g/lbf 3 - 110 Hz, 0.0143 g/lbf
3 - 154.0 Hz, 0.0383 g/lbf 4 - 140 Hz, 0.0198 g/lbf
100m 500m
1
400m

300m
Amplitude g/lbf

Amplitude g/lbf

50m 2
3 200m

100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1206 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA027 1 - 55 Hz, 0.0013 g/lbf PASS


1 - 183.0 Hz, 0.0262 g/lbf 2 - 70 Hz, 0.0017 g/lbf
2 - 190.0 Hz, 0.0232 g/lbf 3 - 110 Hz, 0.0099 g/lbf
3 - 122.0 Hz, 0.0225 g/lbf 4 - 140 Hz, 0.0056 g/lbf
40m 500m

400m
30m
1
3 2 300m
Amplitude g/lbf

Amplitude g/lbf
20m
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER027 1 - 55 Hz, 0.0043 g/lbf PASS


1 - 99.5 Hz, 0.0521 g/lbf 2 - 70 Hz, 0.0022 g/lbf
2 - 65.0 Hz, 0.0356 g/lbf 3 - 110 Hz, 0.0029 g/lbf
3 - 160.0 Hz, 0.0337 g/lbf 4 - 140 Hz, 0.0039 g/lbf
80m 500m

400m
60m
1
300m
Amplitude g/lbf

Amplitude g/lbf

40m 2 3
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET027 1 - 55 Hz, 0.0057 g/lbf PASS


1 - 185.0 Hz, 0.2698 g/lbf 2 - 70 Hz, 0.0067 g/lbf
2 - 158.0 Hz, 0.0953 g/lbf 3 - 110 Hz, 0.0277 g/lbf
3 - 160.0 Hz, 0.0900 g/lbf 4 - 140 Hz, 0.0422 g/lbf
400m 500m

400m
300m 1
300m
Amplitude g/lbf

Amplitude g/lbf

200m
200m
23
100m
100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1207 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA028 1 - 55 Hz, 0.0011 g/lbf PASS


1 - 122.0 Hz, 0.0222 g/lbf 2 - 70 Hz, 0.0014 g/lbf
2 - 189.5 Hz, 0.0172 g/lbf 3 - 110 Hz, 0.0092 g/lbf
3 - 125.0 Hz, 0.0142 g/lbf 4 - 140 Hz, 0.0037 g/lbf
40m 500m

400m
30m

1 300m
Amplitude g/lbf

Amplitude g/lbf
20m 2
3 200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER028 1 - 55 Hz, 0.0049 g/lbf PASS


1 - 99.5 Hz, 0.0655 g/lbf 2 - 70 Hz, 0.0022 g/lbf
2 - 185.5 Hz, 0.0551 g/lbf 3 - 110 Hz, 0.0051 g/lbf
3 - 65.5 Hz, 0.0435 g/lbf 4 - 140 Hz, 0.0031 g/lbf
80m 500m
1
400m
60m 2

300m
Amplitude g/lbf

Amplitude g/lbf

3
40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET028 1 - 55 Hz, 0.0038 g/lbf PASS


1 - 184.5 Hz, 0.0696 g/lbf 2 - 70 Hz, 0.0024 g/lbf
2 - 154.0 Hz, 0.0403 g/lbf 3 - 110 Hz, 0.0148 g/lbf
3 - 158.0 Hz, 0.0402 g/lbf 4 - 140 Hz, 0.0195 g/lbf
100m 500m

400m
1

300m
Amplitude g/lbf

Amplitude g/lbf

50m
23
200m

100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1208 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA029 1 - 55 Hz, 0.0010 g/lbf PASS


1 - 122.0 Hz, 0.0212 g/lbf 2 - 70 Hz, 0.0013 g/lbf
2 - 188.5 Hz, 0.0194 g/lbf 3 - 110 Hz, 0.0083 g/lbf
3 - 125.0 Hz, 0.0120 g/lbf 4 - 140 Hz, 0.0037 g/lbf
40m 500m

400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf
1
20m 2

200m
3
10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER029 1 - 55 Hz, 0.0047 g/lbf PASS


1 - 99.5 Hz, 0.0610 g/lbf 2 - 70 Hz, 0.0023 g/lbf
2 - 185.5 Hz, 0.0524 g/lbf 3 - 110 Hz, 0.0050 g/lbf
3 - 65.5 Hz, 0.0433 g/lbf 4 - 140 Hz, 0.0031 g/lbf
80m 500m

1 400m
60m
2
300m
Amplitude g/lbf

Amplitude g/lbf

3
40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET029 1 - 55 Hz, 0.0044 g/lbf PASS


1 - 192.0 Hz, 0.0868 g/lbf 2 - 70 Hz, 0.0022 g/lbf
2 - 185.5 Hz, 0.0793 g/lbf 3 - 110 Hz, 0.0125 g/lbf
3 - 158.0 Hz, 0.0484 g/lbf 4 - 140 Hz, 0.0199 g/lbf
100m 500m
1
2
400m

300m
Amplitude g/lbf

Amplitude g/lbf

3
50m
200m

100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1209 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA030 1 - 55 Hz, 0.0012 g/lbf PASS


1 - 122.0 Hz, 0.0233 g/lbf 2 - 70 Hz, 0.0010 g/lbf
2 - 187.5 Hz, 0.0153 g/lbf 3 - 110 Hz, 0.0081 g/lbf
3 - 125.0 Hz, 0.0123 g/lbf 4 - 140 Hz, 0.0034 g/lbf
40m 500m

400m
30m
1 300m
Amplitude g/lbf

Amplitude g/lbf
20m
2 200m
3
10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER030 1 - 55 Hz, 0.0045 g/lbf PASS


1 - 99.5 Hz, 0.0529 g/lbf 2 - 70 Hz, 0.0026 g/lbf
2 - 65.0 Hz, 0.0433 g/lbf 3 - 110 Hz, 0.0045 g/lbf
3 - 163.5 Hz, 0.0375 g/lbf 4 - 140 Hz, 0.0033 g/lbf
80m 500m

400m
60m
1
300m
Amplitude g/lbf

Amplitude g/lbf

2
40m 3
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET030 1 - 55 Hz, 0.0049 g/lbf PASS


1 - 185.0 Hz, 0.0980 g/lbf 2 - 70 Hz, 0.0047 g/lbf
2 - 191.5 Hz, 0.0902 g/lbf 3 - 110 Hz, 0.0213 g/lbf
3 - 154.0 Hz, 0.0567 g/lbf 1 4 - 140 Hz, 0.0309 g/lbf
100m 500m
2

400m

3 300m
Amplitude g/lbf

Amplitude g/lbf

50m
200m

100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1210 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA031 1 - 55 Hz, 0.0012 g/lbf PASS


1 - 122.0 Hz, 0.0222 g/lbf 2 - 70 Hz, 0.0009 g/lbf
2 - 188.0 Hz, 0.0211 g/lbf 3 - 110 Hz, 0.0072 g/lbf
3 - 154.5 Hz, 0.0101 g/lbf 4 - 140 Hz, 0.0033 g/lbf
40m 500m

400m
30m

1 300m
Amplitude g/lbf

Amplitude g/lbf
2
20m
200m
3
10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER031 1 - 55 Hz, 0.0047 g/lbf PASS


1 - 65.0 Hz, 0.0416 g/lbf 2 - 70 Hz, 0.0025 g/lbf
2 - 98.0 Hz, 0.0409 g/lbf 3 - 110 Hz, 0.0052 g/lbf
3 - 99.5 Hz, 0.0349 g/lbf 4 - 140 Hz, 0.0047 g/lbf
80m 500m

400m
60m

300m
Amplitude g/lbf

Amplitude g/lbf

1 2
40m 3
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET031 1 - 55 Hz, 0.0022 g/lbf PASS


1 - 186.5 Hz, 0.0389 g/lbf 2 - 70 Hz, 0.0017 g/lbf
2 - 190.5 Hz, 0.0322 g/lbf 3 - 110 Hz, 0.0105 g/lbf
3 - 154.5 Hz, 0.0251 g/lbf 4 - 140 Hz, 0.0127 g/lbf
1
40m 500m

2
400m
30m
3
300m
Amplitude g/lbf

Amplitude g/lbf

20m
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1211 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA032 1 - 55 Hz, 0.0014 g/lbf PASS


1 - 122.0 Hz, 0.0314 g/lbf 2 - 70 Hz, 0.0013 g/lbf
2 - 187.0 Hz, 0.0228 g/lbf 3 - 110 Hz, 0.0102 g/lbf
3 - 154.0 Hz, 0.0167 g/lbf 4 - 140 Hz, 0.0043 g/lbf
40m 500m

1 400m
30m

2 300m
Amplitude g/lbf

Amplitude g/lbf
20m
3
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER032 1 - 55 Hz, 0.0042 g/lbf PASS


1 - 98.0 Hz, 0.0477 g/lbf 2 - 70 Hz, 0.0030 g/lbf
2 - 65.5 Hz, 0.0399 g/lbf 3 - 110 Hz, 0.0034 g/lbf
3 - 134.0 Hz, 0.0351 g/lbf 4 - 140 Hz, 0.0065 g/lbf
50m 1 500m

2
40m 400m
3

30m 300m
Amplitude g/lbf

Amplitude g/lbf

20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET032 1 - 55 Hz, 0.0034 g/lbf PASS


1 - 190.0 Hz, 0.0754 g/lbf 2 - 70 Hz, 0.0026 g/lbf
2 - 154.0 Hz, 0.0386 g/lbf 3 - 110 Hz, 0.0147 g/lbf
3 - 158.0 Hz, 0.0344 g/lbf 4 - 140 Hz, 0.0201 g/lbf
80m 1 500m

400m
60m

300m
Amplitude g/lbf

Amplitude g/lbf

40m 2
3
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1212 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA033 1 - 55 Hz, 0.0012 g/lbf PASS


1 - 122.0 Hz, 0.0243 g/lbf 2 - 70 Hz, 0.0013 g/lbf
2 - 187.5 Hz, 0.0231 g/lbf 3 - 110 Hz, 0.0078 g/lbf
3 - 191.5 Hz, 0.0126 g/lbf 4 - 140 Hz, 0.0034 g/lbf
40m 500m

400m
30m
1
2 300m
Amplitude g/lbf

Amplitude g/lbf
20m
200m
3
10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER033 1 - 55 Hz, 0.0041 g/lbf PASS


1 - 98.0 Hz, 0.0566 g/lbf 2 - 70 Hz, 0.0032 g/lbf
2 - 134.0 Hz, 0.0450 g/lbf 3 - 110 Hz, 0.0032 g/lbf
3 - 65.0 Hz, 0.0380 g/lbf 4 - 140 Hz, 0.0077 g/lbf
80m 500m

400m
60m 1

2 300m
Amplitude g/lbf

Amplitude g/lbf

40m 3

200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET033 1 - 55 Hz, 0.0038 g/lbf PASS


1 - 190.0 Hz, 0.0814 g/lbf 2 - 70 Hz, 0.0036 g/lbf
2 - 154.5 Hz, 0.0422 g/lbf 3 - 110 Hz, 0.0160 g/lbf
3 - 155.5 Hz, 0.0422 g/lbf 4 - 140 Hz, 0.0234 g/lbf
100m 500m

1
400m

300m
Amplitude g/lbf

Amplitude g/lbf

50m 23
200m

100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1213 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA034 1 - 55 Hz, 0.0013 g/lbf PASS


1 - 122.0 Hz, 0.0261 g/lbf 2 - 70 Hz, 0.0010 g/lbf
2 - 189.5 Hz, 0.0187 g/lbf 3 - 110 Hz, 0.0082 g/lbf
3 - 155.5 Hz, 0.0128 g/lbf 4 - 140 Hz, 0.0034 g/lbf
40m 500m

400m
30m
1
300m
Amplitude g/lbf

Amplitude g/lbf
20m 2
200m
3
10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER034 1 - 55 Hz, 0.0038 g/lbf PASS


1 - 98.0 Hz, 0.0603 g/lbf 2 - 70 Hz, 0.0033 g/lbf
2 - 134.0 Hz, 0.0484 g/lbf 3 - 110 Hz, 0.0029 g/lbf
3 - 65.5 Hz, 0.0364 g/lbf 4 - 140 Hz, 0.0078 g/lbf
80m 500m

1 400m
60m
2
300m
Amplitude g/lbf

Amplitude g/lbf

40m 3
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET034 1 - 55 Hz, 0.0019 g/lbf PASS


1 - 190.0 Hz, 0.0390 g/lbf 2 - 70 Hz, 0.0005 g/lbf
2 - 155.5 Hz, 0.0198 g/lbf 3 - 110 Hz, 0.0069 g/lbf
3 - 159.5 Hz, 0.0172 g/lbf 1 4 - 140 Hz, 0.0080 g/lbf
40m 500m

400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf

2
20m 3
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1214 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA035 1 - 55 Hz, 0.0013 g/lbf PASS


1 - 122.0 Hz, 0.0253 g/lbf 2 - 70 Hz, 0.0007 g/lbf
2 - 188.5 Hz, 0.0142 g/lbf 3 - 110 Hz, 0.0068 g/lbf
3 - 154.5 Hz, 0.0109 g/lbf 4 - 140 Hz, 0.0028 g/lbf
40m 500m

400m
30m
1
300m
Amplitude g/lbf

Amplitude g/lbf
20m
2 200m
3
10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER035 1 - 55 Hz, 0.0038 g/lbf PASS


1 - 98.0 Hz, 0.0609 g/lbf 2 - 70 Hz, 0.0033 g/lbf
2 - 134.0 Hz, 0.0461 g/lbf 3 - 110 Hz, 0.0029 g/lbf
3 - 66.0 Hz, 0.0368 g/lbf 4 - 140 Hz, 0.0073 g/lbf
80m 500m

1 400m
60m

2 300m
Amplitude g/lbf

Amplitude g/lbf

40m 3
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET035 1 - 55 Hz, 0.0033 g/lbf PASS


1 - 189.5 Hz, 0.0646 g/lbf 2 - 70 Hz, 0.0022 g/lbf
2 - 187.0 Hz, 0.0627 g/lbf 3 - 110 Hz, 0.0129 g/lbf
3 - 155.5 Hz, 0.0421 g/lbf 4 - 140 Hz, 0.0168 g/lbf
80m 500m

21 400m
60m

300m
Amplitude g/lbf

Amplitude g/lbf

3
40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1215 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA036 1 - 55 Hz, 0.0011 g/lbf PASS


1 - 122.0 Hz, 0.0259 g/lbf 2 - 70 Hz, 0.0010 g/lbf
2 - 190.0 Hz, 0.0176 g/lbf 3 - 110 Hz, 0.0079 g/lbf
3 - 156.0 Hz, 0.0108 g/lbf 4 - 140 Hz, 0.0029 g/lbf
40m 500m

400m
30m
1
300m
Amplitude g/lbf

Amplitude g/lbf
20m 2
200m
3
10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER036 1 - 55 Hz, 0.0042 g/lbf PASS


1 - 98.0 Hz, 0.0548 g/lbf 2 - 70 Hz, 0.0029 g/lbf
2 - 66.0 Hz, 0.0428 g/lbf 3 - 110 Hz, 0.0039 g/lbf
3 - 131.5 Hz, 0.0367 g/lbf 4 - 140 Hz, 0.0045 g/lbf
400m 500m

400m
300m

300m
Amplitude g/lbf

Amplitude g/lbf

200m
200m

100m
1 100m
2 3
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET036 1 - 55 Hz, 0.0032 g/lbf PASS


1 - 186.5 Hz, 0.0618 g/lbf 2 - 70 Hz, 0.0028 g/lbf
2 - 159.5 Hz, 0.0440 g/lbf 3 - 110 Hz, 0.0133 g/lbf
3 - 155.5 Hz, 0.0424 g/lbf 4 - 140 Hz, 0.0186 g/lbf
80m 500m

1 400m
60m

32 300m
Amplitude g/lbf

Amplitude g/lbf

40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1216 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA037 1 - 55 Hz, 0.0011 g/lbf PASS


1 - 122.0 Hz, 0.0252 g/lbf 2 - 70 Hz, 0.0011 g/lbf
2 - 190.0 Hz, 0.0208 g/lbf 3 - 110 Hz, 0.0081 g/lbf
3 - 156.0 Hz, 0.0129 g/lbf 4 - 140 Hz, 0.0032 g/lbf
40m 500m

400m
30m
1
300m
Amplitude g/lbf

Amplitude g/lbf
2
20m
200m
3
10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER037 1 - 55 Hz, 0.0043 g/lbf PASS


1 - 131.5 Hz, 0.0489 g/lbf 2 - 70 Hz, 0.0025 g/lbf
2 - 66.0 Hz, 0.0472 g/lbf 3 - 110 Hz, 0.0046 g/lbf
3 - 163.0 Hz, 0.0459 g/lbf 4 - 140 Hz, 0.0029 g/lbf
1
50m 2 3 500m

40m 400m

30m 300m
Amplitude g/lbf

Amplitude g/lbf

20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET037 1 - 55 Hz, 0.0034 g/lbf PASS


1 - 186.5 Hz, 0.0652 g/lbf 2 - 70 Hz, 0.0031 g/lbf
2 - 159.5 Hz, 0.0514 g/lbf 3 - 110 Hz, 0.0146 g/lbf
3 - 155.5 Hz, 0.0458 g/lbf 4 - 140 Hz, 0.0196 g/lbf
80m 500m

1
400m
60m
2
3 300m
Amplitude g/lbf

Amplitude g/lbf

40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1217 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA038 1 - 55 Hz, 0.0010 g/lbf PASS


1 - 122.0 Hz, 0.0231 g/lbf 2 - 70 Hz, 0.0011 g/lbf
2 - 190.0 Hz, 0.0189 g/lbf 3 - 110 Hz, 0.0080 g/lbf
3 - 155.5 Hz, 0.0122 g/lbf 4 - 140 Hz, 0.0031 g/lbf
40m 500m

400m
30m

1 300m
Amplitude g/lbf

Amplitude g/lbf
20m 2
200m
3
10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER038 1 - 55 Hz, 0.0043 g/lbf PASS


1 - 131.5 Hz, 0.0662 g/lbf 2 - 70 Hz, 0.0027 g/lbf
2 - 66.0 Hz, 0.0520 g/lbf 3 - 110 Hz, 0.0044 g/lbf
3 - 163.0 Hz, 0.0492 g/lbf 4 - 140 Hz, 0.0038 g/lbf
80m 500m
1
400m
60m
2
3
300m
Amplitude g/lbf

Amplitude g/lbf

40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET038 1 - 55 Hz, 0.0023 g/lbf PASS


1 - 187.0 Hz, 0.0405 g/lbf 2 - 70 Hz, 0.0018 g/lbf
2 - 159.5 Hz, 0.0325 g/lbf 3 - 110 Hz, 0.0094 g/lbf
3 - 155.5 Hz, 0.0274 g/lbf 4 - 140 Hz, 0.0131 g/lbf
80m 500m

400m
60m

300m
Amplitude g/lbf

Amplitude g/lbf

1
40m
2
3 200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1218 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA039 1 - 55 Hz, 0.0014 g/lbf PASS


1 - 66.0 Hz, 0.0162 g/lbf 2 - 70 Hz, 0.0006 g/lbf
2 - 99.5 Hz, 0.0159 g/lbf 3 - 110 Hz, 0.0023 g/lbf
3 - 190.0 Hz, 0.0110 g/lbf 4 - 140 Hz, 0.0010 g/lbf
50m 500m

40m 400m

30m 300m
Amplitude g/lbf

Amplitude g/lbf
20m 1 200m
2
3
10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER039 1 - 55 Hz, 0.0039 g/lbf PASS


1 - 131.5 Hz, 0.0593 g/lbf 2 - 70 Hz, 0.0028 g/lbf
2 - 99.5 Hz, 0.0553 g/lbf 3 - 110 Hz, 0.0041 g/lbf
3 - 66.0 Hz, 0.0510 g/lbf 4 - 140 Hz, 0.0062 g/lbf
80m 500m

1 400m
60m 2
3
300m
Amplitude g/lbf

Amplitude g/lbf

40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET039 1 - 55 Hz, 0.0023 g/lbf PASS


1 - 188.0 Hz, 0.0440 g/lbf 2 - 70 Hz, 0.0015 g/lbf
2 - 158.5 Hz, 0.0251 g/lbf 3 - 110 Hz, 0.0078 g/lbf
3 - 159.5 Hz, 0.0246 g/lbf 4 - 140 Hz, 0.0123 g/lbf
50m 500m
1

40m 400m

30m 300m
Amplitude g/lbf

Amplitude g/lbf

23

20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1219 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA040 1 - 55 Hz, 0.0012 g/lbf PASS


1 - 122.0 Hz, 0.0121 g/lbf 2 - 70 Hz, 0.0004 g/lbf
2 - 66.0 Hz, 0.0120 g/lbf 3 - 110 Hz, 0.0034 g/lbf
3 - 99.5 Hz, 0.0113 g/lbf 4 - 140 Hz, 0.0016 g/lbf
100m 500m

400m

300m
Amplitude g/lbf

Amplitude g/lbf
50m
200m

100m
2 3 1
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER040 1 - 55 Hz, 0.0035 g/lbf PASS


1 - 99.5 Hz, 0.0525 g/lbf 2 - 70 Hz, 0.0028 g/lbf
2 - 131.5 Hz, 0.0493 g/lbf 3 - 110 Hz, 0.0039 g/lbf
3 - 66.0 Hz, 0.0458 g/lbf 4 - 140 Hz, 0.0064 g/lbf
80m 500m

400m
60m
1
2
3 300m
Amplitude g/lbf

Amplitude g/lbf

40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET040 1 - 55 Hz, 0.0026 g/lbf PASS


1 - 187.5 Hz, 0.0544 g/lbf 2 - 70 Hz, 0.0023 g/lbf
2 - 158.0 Hz, 0.0314 g/lbf 3 - 110 Hz, 0.0108 g/lbf
3 - 154.0 Hz, 0.0313 g/lbf 4 - 140 Hz, 0.0158 g/lbf
80m 500m

400m
60m 1

300m
Amplitude g/lbf

Amplitude g/lbf

40m
32
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1220 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA041 1 - 55 Hz, 0.0013 g/lbf PASS


1 - 187.5 Hz, 0.0149 g/lbf 2 - 70 Hz, 0.0003 g/lbf
2 - 122.0 Hz, 0.0129 g/lbf 3 - 110 Hz, 0.0044 g/lbf
3 - 66.0 Hz, 0.0092 g/lbf 4 - 140 Hz, 0.0019 g/lbf
20m 500m

1 400m
15m
2
300m
Amplitude g/lbf

Amplitude g/lbf
10m 3
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER041 1 - 55 Hz, 0.0036 g/lbf PASS


1 - 99.5 Hz, 0.0525 g/lbf 2 - 70 Hz, 0.0031 g/lbf
2 - 134.0 Hz, 0.0466 g/lbf 3 - 110 Hz, 0.0035 g/lbf
3 - 66.0 Hz, 0.0457 g/lbf 4 - 140 Hz, 0.0073 g/lbf
80m 500m

400m
60m
1
3 2
300m
Amplitude g/lbf

Amplitude g/lbf

40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET041 1 - 55 Hz, 0.0022 g/lbf PASS


1 - 187.0 Hz, 0.0349 g/lbf 2 - 70 Hz, 0.0015 g/lbf
2 - 190.0 Hz, 0.0301 g/lbf 3 - 110 Hz, 0.0078 g/lbf
3 - 154.0 Hz, 0.0232 g/lbf 4 - 140 Hz, 0.0113 g/lbf
40m 500m
1

2 400m
30m

3 300m
Amplitude g/lbf

Amplitude g/lbf

20m
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1221 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA042 1 - 55 Hz, 0.0012 g/lbf PASS


1 - 187.5 Hz, 0.0165 g/lbf 2 - 70 Hz, 0.0005 g/lbf
2 - 122.0 Hz, 0.0134 g/lbf 3 - 110 Hz, 0.0058 g/lbf
3 - 160.0 Hz, 0.0090 g/lbf 4 - 140 Hz, 0.0022 g/lbf
20m 500m
1
400m
15m
2
300m
Amplitude g/lbf

Amplitude g/lbf
10m 3
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER042 1 - 55 Hz, 0.0033 g/lbf PASS


1 - 133.5 Hz, 0.0452 g/lbf 2 - 70 Hz, 0.0030 g/lbf
2 - 99.5 Hz, 0.0430 g/lbf 3 - 110 Hz, 0.0031 g/lbf
3 - 66.0 Hz, 0.0386 g/lbf 4 - 140 Hz, 0.0068 g/lbf
50m 500m
1
2
40m 3 400m

30m 300m
Amplitude g/lbf

Amplitude g/lbf

20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET042 1 - 55 Hz, 0.0019 g/lbf PASS


1 - 186.5 Hz, 0.0301 g/lbf 2 - 70 Hz, 0.0013 g/lbf
2 - 190.0 Hz, 0.0289 g/lbf 3 - 110 Hz, 0.0074 g/lbf
3 - 154.0 Hz, 0.0209 g/lbf 4 - 140 Hz, 0.0097 g/lbf
80m 500m

400m
60m

300m
Amplitude g/lbf

Amplitude g/lbf

40m
12 200m
3
20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1222 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA043 1 - 55 Hz, 0.0013 g/lbf PASS


1 - 187.0 Hz, 0.0179 g/lbf 2 - 70 Hz, 0.0008 g/lbf
2 - 122.0 Hz, 0.0146 g/lbf 3 - 110 Hz, 0.0072 g/lbf
3 - 154.5 Hz, 0.0118 g/lbf 4 - 140 Hz, 0.0032 g/lbf
20m 500m
1

2 400m
15m
3
300m
Amplitude g/lbf

Amplitude g/lbf
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER043 1 - 55 Hz, 0.0034 g/lbf PASS


1 - 134.0 Hz, 0.0401 g/lbf 2 - 70 Hz, 0.0031 g/lbf
2 - 66.0 Hz, 0.0345 g/lbf 3 - 110 Hz, 0.0026 g/lbf
3 - 99.5 Hz, 0.0341 g/lbf 4 - 140 Hz, 0.0055 g/lbf
50m 500m

1
40m 400m
2 3

30m 300m
Amplitude g/lbf

Amplitude g/lbf

20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET043 1 - 55 Hz, 0.0024 g/lbf PASS


1 - 190.0 Hz, 0.0418 g/lbf 2 - 70 Hz, 0.0019 g/lbf
2 - 186.5 Hz, 0.0395 g/lbf 3 - 110 Hz, 0.0098 g/lbf
3 - 158.0 Hz, 0.0280 g/lbf 4 - 140 Hz, 0.0123 g/lbf
50m 500m
1
2
40m 400m

30m 3 300m
Amplitude g/lbf

Amplitude g/lbf

20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1223 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA044 1 - 55 Hz, 0.0012 g/lbf PASS


1 - 187.0 Hz, 0.0130 g/lbf 2 - 70 Hz, 0.0006 g/lbf
2 - 122.5 Hz, 0.0125 g/lbf 3 - 110 Hz, 0.0059 g/lbf
3 - 125.0 Hz, 0.0105 g/lbf 4 - 140 Hz, 0.0022 g/lbf
20m 500m

400m
15m
2 1
300m
Amplitude g/lbf

Amplitude g/lbf
3
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER044 1 - 55 Hz, 0.0035 g/lbf PASS


1 - 98.0 Hz, 0.0377 g/lbf 2 - 70 Hz, 0.0028 g/lbf
2 - 163.5 Hz, 0.0347 g/lbf 3 - 110 Hz, 0.0030 g/lbf
3 - 65.0 Hz, 0.0341 g/lbf 4 - 140 Hz, 0.0028 g/lbf
40m 1 500m
3 2
400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf

20m
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET044 1 - 55 Hz, 0.0015 g/lbf PASS


1 - 190.0 Hz, 0.0220 g/lbf 2 - 70 Hz, 0.0006 g/lbf
2 - 154.5 Hz, 0.0145 g/lbf 3 - 110 Hz, 0.0049 g/lbf
3 - 158.0 Hz, 0.0135 g/lbf 4 - 140 Hz, 0.0062 g/lbf
40m 500m

400m
30m

1 300m
Amplitude g/lbf

Amplitude g/lbf

20m
23 200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1224 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA045 1 - 55 Hz, 0.0013 g/lbf PASS


1 - 125.0 Hz, 0.0149 g/lbf 2 - 70 Hz, 0.0008 g/lbf
2 - 186.0 Hz, 0.0141 g/lbf 3 - 110 Hz, 0.0073 g/lbf
3 - 123.0 Hz, 0.0141 g/lbf 4 - 140 Hz, 0.0031 g/lbf
20m 500m

1 400m
15m 3 2

300m
Amplitude g/lbf

Amplitude g/lbf
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER045 1 - 55 Hz, 0.0033 g/lbf PASS


1 - 98.0 Hz, 0.0410 g/lbf 2 - 70 Hz, 0.0027 g/lbf
2 - 65.0 Hz, 0.0343 g/lbf 3 - 110 Hz, 0.0032 g/lbf
3 - 163.5 Hz, 0.0340 g/lbf 4 - 140 Hz, 0.0033 g/lbf
50m 500m
1
40m 400m
2 3

30m 300m
Amplitude g/lbf

Amplitude g/lbf

20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET045 1 - 55 Hz, 0.0030 g/lbf PASS


1 - 189.0 Hz, 0.0462 g/lbf 2 - 70 Hz, 0.0013 g/lbf
2 - 154.0 Hz, 0.0289 g/lbf 3 - 110 Hz, 0.0096 g/lbf
3 - 157.5 Hz, 0.0261 g/lbf 4 - 140 Hz, 0.0128 g/lbf
80m 500m

400m
60m

1 300m
Amplitude g/lbf

Amplitude g/lbf

40m
2 200m
3
20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1225 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA046 1 - 55 Hz, 0.0009 g/lbf PASS


1 - 125.0 Hz, 0.0148 g/lbf 2 - 70 Hz, 0.0009 g/lbf
2 - 123.0 Hz, 0.0135 g/lbf 3 - 110 Hz, 0.0074 g/lbf
3 - 127.0 Hz, 0.0134 g/lbf 4 - 140 Hz, 0.0025 g/lbf
20m 500m

1 400m
15m 23
300m
Amplitude g/lbf

Amplitude g/lbf
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER046 1 - 55 Hz, 0.0034 g/lbf PASS


1 - 98.0 Hz, 0.0435 g/lbf 2 - 70 Hz, 0.0027 g/lbf
2 - 65.5 Hz, 0.0378 g/lbf 3 - 110 Hz, 0.0030 g/lbf
3 - 159.5 Hz, 0.0327 g/lbf 4 - 140 Hz, 0.0032 g/lbf
50m 500m
1
40m 2 400m
3
30m 300m
Amplitude g/lbf

Amplitude g/lbf

20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET046 1 - 55 Hz, 0.0017 g/lbf PASS


1 - 187.5 Hz, 0.0181 g/lbf 2 - 70 Hz, 0.0005 g/lbf
2 - 154.5 Hz, 0.0121 g/lbf 3 - 110 Hz, 0.0042 g/lbf
3 - 164.0 Hz, 0.0120 g/lbf 4 - 140 Hz, 0.0061 g/lbf
20m 500m
1

400m
15m
2 3
300m
Amplitude g/lbf

Amplitude g/lbf

10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1226 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA047 1 - 55 Hz, 0.0008 g/lbf PASS


1 - 125.0 Hz, 0.0154 g/lbf 2 - 70 Hz, 0.0006 g/lbf
2 - 187.0 Hz, 0.0102 g/lbf 3 - 110 Hz, 0.0062 g/lbf
3 - 190.5 Hz, 0.0093 g/lbf 4 - 140 Hz, 0.0019 g/lbf
80m 500m

400m
60m

300m
Amplitude g/lbf

Amplitude g/lbf
40m
200m

20m 1
23 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER047 1 - 55 Hz, 0.0032 g/lbf PASS


1 - 98.0 Hz, 0.0406 g/lbf 2 - 70 Hz, 0.0030 g/lbf
2 - 65.0 Hz, 0.0385 g/lbf 3 - 110 Hz, 0.0021 g/lbf
3 - 160.0 Hz, 0.0350 g/lbf 4 - 140 Hz, 0.0040 g/lbf
50m 500m
1
40m 2 400m
3

30m 300m
Amplitude g/lbf

Amplitude g/lbf

20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET047 1 - 55 Hz, 0.0018 g/lbf PASS


1 - 187.0 Hz, 0.0195 g/lbf 2 - 70 Hz, 0.0003 g/lbf
2 - 164.5 Hz, 0.0141 g/lbf 3 - 110 Hz, 0.0041 g/lbf
3 - 154.5 Hz, 0.0135 g/lbf 4 - 140 Hz, 0.0059 g/lbf
200m 500m

400m

300m
Amplitude g/lbf

Amplitude g/lbf

100m
200m

100m
3 2 1
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1227 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA048 1 - 55 Hz, 0.0009 g/lbf PASS


1 - 125.0 Hz, 0.0188 g/lbf 2 - 70 Hz, 0.0008 g/lbf
2 - 186.5 Hz, 0.0115 g/lbf 3 - 110 Hz, 0.0074 g/lbf
3 - 190.0 Hz, 0.0107 g/lbf 4 - 140 Hz, 0.0023 g/lbf
20m 1 500m

400m
15m

2 300m
Amplitude g/lbf

Amplitude g/lbf
3
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER048 1 - 55 Hz, 0.0031 g/lbf PASS


1 - 65.5 Hz, 0.0388 g/lbf 2 - 70 Hz, 0.0028 g/lbf
2 - 98.0 Hz, 0.0368 g/lbf 3 - 110 Hz, 0.0018 g/lbf
3 - 160.0 Hz, 0.0366 g/lbf 4 - 140 Hz, 0.0043 g/lbf
40m 1
2 3 500m

400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf

20m
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET048 1 - 55 Hz, 0.0016 g/lbf PASS


1 - 186.5 Hz, 0.0226 g/lbf 2 - 70 Hz, 0.0004 g/lbf
2 - 164.0 Hz, 0.0151 g/lbf 3 - 110 Hz, 0.0050 g/lbf
3 - 154.5 Hz, 0.0151 g/lbf 4 - 140 Hz, 0.0068 g/lbf
40m 500m

400m
30m

1 300m
Amplitude g/lbf

Amplitude g/lbf

20m
3 2 200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1228 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA049 1 - 55 Hz, 0.0011 g/lbf PASS


1 - 125.0 Hz, 0.0207 g/lbf 2 - 70 Hz, 0.0009 g/lbf
2 - 186.5 Hz, 0.0144 g/lbf 3 - 110 Hz, 0.0079 g/lbf
3 - 190.0 Hz, 0.0131 g/lbf 4 - 140 Hz, 0.0028 g/lbf
40m 500m

400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf
1
20m
2 200m
3
10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER049 1 - 55 Hz, 0.0030 g/lbf PASS


1 - 65.5 Hz, 0.0370 g/lbf 2 - 70 Hz, 0.0030 g/lbf
2 - 160.0 Hz, 0.0308 g/lbf 3 - 110 Hz, 0.0013 g/lbf
3 - 98.0 Hz, 0.0307 g/lbf 4 - 140 Hz, 0.0040 g/lbf
40m 1 500m

3 2 400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf

20m
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET049 1 - 55 Hz, 0.0021 g/lbf PASS


1 - 186.0 Hz, 0.0269 g/lbf 2 - 70 Hz, 0.0008 g/lbf
2 - 160.0 Hz, 0.0201 g/lbf 3 - 110 Hz, 0.0069 g/lbf
3 - 154.5 Hz, 0.0192 g/lbf 4 - 140 Hz, 0.0090 g/lbf
50m 500m

40m 400m

30m 300m
Amplitude g/lbf

Amplitude g/lbf

20m 32 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1229 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA050 1 - 55 Hz, 0.0009 g/lbf PASS


1 - 125.0 Hz, 0.0192 g/lbf 2 - 70 Hz, 0.0008 g/lbf
2 - 190.5 Hz, 0.0144 g/lbf 3 - 110 Hz, 0.0071 g/lbf
3 - 186.5 Hz, 0.0125 g/lbf 4 - 140 Hz, 0.0025 g/lbf
80m 500m

400m
60m

300m
Amplitude g/lbf

Amplitude g/lbf
40m
200m
1
20m
32 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER050 1 - 55 Hz, 0.0031 g/lbf PASS


1 - 99.5 Hz, 0.0370 g/lbf 2 - 70 Hz, 0.0030 g/lbf
2 - 65.5 Hz, 0.0346 g/lbf 3 - 110 Hz, 0.0014 g/lbf
3 - 134.0 Hz, 0.0270 g/lbf 4 - 140 Hz, 0.0042 g/lbf
40m 1 500m
2
400m
30m 3

300m
Amplitude g/lbf

Amplitude g/lbf

20m
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET050 1 - 55 Hz, 0.0022 g/lbf PASS


1 - 192.0 Hz, 0.0237 g/lbf 2 - 70 Hz, 0.0006 g/lbf
2 - 186.0 Hz, 0.0231 g/lbf 3 - 110 Hz, 0.0064 g/lbf
3 - 160.0 Hz, 0.0223 g/lbf 4 - 140 Hz, 0.0087 g/lbf
40m 500m

400m
30m

3 21 300m
Amplitude g/lbf

Amplitude g/lbf

20m
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1230 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA051 1 - 55 Hz, 0.0012 g/lbf PASS


1 - 125.0 Hz, 0.0159 g/lbf 2 - 70 Hz, 0.0006 g/lbf
2 - 186.0 Hz, 0.0138 g/lbf 3 - 110 Hz, 0.0059 g/lbf
3 - 190.0 Hz, 0.0108 g/lbf 4 - 140 Hz, 0.0022 g/lbf
20m 500m

1
400m
15m 2

300m
Amplitude g/lbf

Amplitude g/lbf
3
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER051 1 - 55 Hz, 0.0031 g/lbf PASS


1 - 99.5 Hz, 0.0445 g/lbf 2 - 70 Hz, 0.0030 g/lbf
2 - 134.0 Hz, 0.0332 g/lbf 3 - 110 Hz, 0.0014 g/lbf
3 - 65.5 Hz, 0.0327 g/lbf 4 - 140 Hz, 0.0044 g/lbf
50m 500m
1

40m 400m
3 2
30m 300m
Amplitude g/lbf

Amplitude g/lbf

20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET051 1 - 55 Hz, 0.0024 g/lbf PASS


1 - 186.0 Hz, 0.0258 g/lbf 2 - 70 Hz, 0.0007 g/lbf
2 - 191.5 Hz, 0.0256 g/lbf 3 - 110 Hz, 0.0075 g/lbf
3 - 160.0 Hz, 0.0241 g/lbf 4 - 140 Hz, 0.0093 g/lbf
40m 500m

400m
30m
12
3
300m
Amplitude g/lbf

Amplitude g/lbf

20m
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1231 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA052 1 - 55 Hz, 0.0012 g/lbf PASS


1 - 125.0 Hz, 0.0206 g/lbf 2 - 70 Hz, 0.0009 g/lbf
2 - 190.0 Hz, 0.0155 g/lbf 3 - 110 Hz, 0.0082 g/lbf
3 - 160.5 Hz, 0.0108 g/lbf 4 - 140 Hz, 0.0033 g/lbf
40m 500m

400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf
1
20m
2
200m
3
10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER052 1 - 55 Hz, 0.0027 g/lbf PASS


1 - 99.5 Hz, 0.0465 g/lbf 2 - 70 Hz, 0.0032 g/lbf
2 - 134.0 Hz, 0.0307 g/lbf 3 - 110 Hz, 0.0013 g/lbf
3 - 65.5 Hz, 0.0285 g/lbf 4 - 140 Hz, 0.0038 g/lbf
50m 1 500m

40m 400m

2
30m 3 300m
Amplitude g/lbf

Amplitude g/lbf

20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET052 1 - 55 Hz, 0.0024 g/lbf PASS


1 - 191.5 Hz, 0.0367 g/lbf 2 - 70 Hz, 0.0019 g/lbf
2 - 187.0 Hz, 0.0349 g/lbf 3 - 110 Hz, 0.0096 g/lbf
3 - 159.5 Hz, 0.0273 g/lbf 4 - 140 Hz, 0.0133 g/lbf
50m 500m

40m 1 400m
2

30m 300m
Amplitude g/lbf

3
Amplitude g/lbf

20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1232 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA053 1 - 55 Hz, 0.0012 g/lbf PASS


1 - 125.0 Hz, 0.0190 g/lbf 2 - 70 Hz, 0.0009 g/lbf
2 - 190.0 Hz, 0.0132 g/lbf 3 - 110 Hz, 0.0077 g/lbf
3 - 154.5 Hz, 0.0100 g/lbf 4 - 140 Hz, 0.0030 g/lbf
20m 1 500m

400m
15m
2
300m
Amplitude g/lbf

Amplitude g/lbf
3
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER053 1 - 55 Hz, 0.0028 g/lbf PASS


1 - 99.5 Hz, 0.0457 g/lbf 2 - 70 Hz, 0.0037 g/lbf
2 - 66.0 Hz, 0.0337 g/lbf 3 - 110 Hz, 0.0016 g/lbf
3 - 134.0 Hz, 0.0270 g/lbf 4 - 140 Hz, 0.0040 g/lbf
50m 1 500m

40m 400m
2
30m 300m
Amplitude g/lbf

Amplitude g/lbf

20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET053 1 - 55 Hz, 0.0026 g/lbf PASS


1 - 186.0 Hz, 0.0390 g/lbf 2 - 70 Hz, 0.0020 g/lbf
2 - 192.5 Hz, 0.0348 g/lbf 3 - 110 Hz, 0.0098 g/lbf
3 - 159.5 Hz, 0.0289 g/lbf 4 - 140 Hz, 0.0143 g/lbf
50m 500m

1
40m 400m
2

30m 3 300m
Amplitude g/lbf

Amplitude g/lbf

20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1233 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA054 1 - 55 Hz, 0.0010 g/lbf PASS


1 - 125.0 Hz, 0.0180 g/lbf 2 - 70 Hz, 0.0007 g/lbf
2 - 127.0 Hz, 0.0137 g/lbf 3 - 110 Hz, 0.0073 g/lbf
3 - 187.5 Hz, 0.0123 g/lbf 4 - 140 Hz, 0.0027 g/lbf
20m 500m
1

400m
15m 2
3
300m
Amplitude g/lbf

Amplitude g/lbf
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER054 1 - 55 Hz, 0.0032 g/lbf PASS


1 - 99.5 Hz, 0.0430 g/lbf 2 - 70 Hz, 0.0039 g/lbf
2 - 66.0 Hz, 0.0420 g/lbf 3 - 110 Hz, 0.0014 g/lbf
3 - 98.0 Hz, 0.0280 g/lbf 4 - 140 Hz, 0.0042 g/lbf
50m 500m
2 1
40m 400m

30m 3 300m
Amplitude g/lbf

Amplitude g/lbf

20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET054 1 - 55 Hz, 0.0018 g/lbf PASS


1 - 186.0 Hz, 0.0241 g/lbf 2 - 70 Hz, 0.0006 g/lbf
2 - 159.5 Hz, 0.0197 g/lbf 3 - 110 Hz, 0.0055 g/lbf
3 - 155.5 Hz, 0.0194 g/lbf 4 - 140 Hz, 0.0067 g/lbf
40m 500m

400m
30m
1
300m
Amplitude g/lbf

Amplitude g/lbf

20m 32

200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1234 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA055 1 - 55 Hz, 0.0014 g/lbf PASS


1 - 66.0 Hz, 0.0129 g/lbf 2 - 70 Hz, 0.0007 g/lbf
2 - 132.0 Hz, 0.0113 g/lbf 3 - 110 Hz, 0.0049 g/lbf
3 - 186.5 Hz, 0.0110 g/lbf 4 - 140 Hz, 0.0023 g/lbf
20m 500m

400m
15m
1
2 3 300m
Amplitude g/lbf

Amplitude g/lbf
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER055 1 - 55 Hz, 0.0034 g/lbf PASS


1 - 66.0 Hz, 0.0489 g/lbf 2 - 70 Hz, 0.0044 g/lbf
2 - 99.5 Hz, 0.0387 g/lbf 3 - 110 Hz, 0.0016 g/lbf
3 - 98.0 Hz, 0.0340 g/lbf 4 - 140 Hz, 0.0048 g/lbf
1
50m 500m

40m 2 400m
3

30m 300m
Amplitude g/lbf

Amplitude g/lbf

20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET055 1 - 55 Hz, 0.0021 g/lbf PASS


1 - 186.0 Hz, 0.0335 g/lbf 2 - 70 Hz, 0.0008 g/lbf
2 - 159.5 Hz, 0.0259 g/lbf 3 - 110 Hz, 0.0067 g/lbf
3 - 155.5 Hz, 0.0248 g/lbf 4 - 140 Hz, 0.0085 g/lbf
40m 500m
1
400m
30m
32
300m
Amplitude g/lbf

Amplitude g/lbf

20m
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1235 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA056 1 - 55 Hz, 0.0016 g/lbf PASS


1 - 66.0 Hz, 0.0156 g/lbf 2 - 70 Hz, 0.0010 g/lbf
2 - 186.0 Hz, 0.0142 g/lbf 3 - 110 Hz, 0.0038 g/lbf
3 - 132.0 Hz, 0.0128 g/lbf 4 - 140 Hz, 0.0021 g/lbf
20m 500m

1 400m
15m 2
3
300m
Amplitude g/lbf

Amplitude g/lbf
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER056 1 - 55 Hz, 0.0033 g/lbf PASS


1 - 66.0 Hz, 0.0513 g/lbf 2 - 70 Hz, 0.0044 g/lbf
2 - 98.0 Hz, 0.0417 g/lbf 3 - 110 Hz, 0.0014 g/lbf
3 - 132.0 Hz, 0.0356 g/lbf 4 - 140 Hz, 0.0042 g/lbf
80m 500m

400m
60m
1
300m
Amplitude g/lbf

Amplitude g/lbf

2
40m 3
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET056 1 - 55 Hz, 0.0019 g/lbf PASS


1 - 186.5 Hz, 0.0326 g/lbf 2 - 70 Hz, 0.0011 g/lbf
2 - 159.5 Hz, 0.0239 g/lbf 3 - 110 Hz, 0.0070 g/lbf
3 - 155.5 Hz, 0.0229 g/lbf 4 - 140 Hz, 0.0088 g/lbf
40m 500m
1
400m
30m

32 300m
Amplitude g/lbf

Amplitude g/lbf

20m
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1236 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA057 1 - 55 Hz, 0.0012 g/lbf PASS


1 - 187.0 Hz, 0.0196 g/lbf 2 - 70 Hz, 0.0013 g/lbf
2 - 123.0 Hz, 0.0192 g/lbf 3 - 110 Hz, 0.0092 g/lbf
3 - 155.5 Hz, 0.0188 g/lbf 1 4 - 140 Hz, 0.0036 g/lbf
20m 2 3 500m

400m
15m

300m
Amplitude g/lbf

Amplitude g/lbf
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER057 1 - 55 Hz, 0.0032 g/lbf PASS


1 - 66.0 Hz, 0.0491 g/lbf 2 - 70 Hz, 0.0043 g/lbf
2 - 98.0 Hz, 0.0455 g/lbf 3 - 110 Hz, 0.0012 g/lbf
3 - 132.0 Hz, 0.0328 g/lbf 4 - 140 Hz, 0.0041 g/lbf
1
50m 2 500m

40m 400m
3
30m 300m
Amplitude g/lbf

Amplitude g/lbf

20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET057 1 - 55 Hz, 0.0022 g/lbf PASS


1 - 189.5 Hz, 0.0361 g/lbf 2 - 70 Hz, 0.0021 g/lbf
2 - 186.5 Hz, 0.0347 g/lbf 3 - 110 Hz, 0.0093 g/lbf
3 - 159.5 Hz, 0.0308 g/lbf 4 - 140 Hz, 0.0133 g/lbf
40m 500m
1
2
3 400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf

20m
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1237 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA058 1 - 55 Hz, 0.0011 g/lbf PASS


1 - 123.0 Hz, 0.0178 g/lbf 2 - 70 Hz, 0.0011 g/lbf
2 - 155.5 Hz, 0.0147 g/lbf 3 - 110 Hz, 0.0082 g/lbf
3 - 187.5 Hz, 0.0138 g/lbf 4 - 140 Hz, 0.0029 g/lbf
20m 500m
1

2 400m
15m 3

300m
Amplitude g/lbf

Amplitude g/lbf
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER058 1 - 55 Hz, 0.0036 g/lbf PASS


1 - 98.0 Hz, 0.0540 g/lbf 2 - 70 Hz, 0.0046 g/lbf
2 - 66.0 Hz, 0.0515 g/lbf 3 - 110 Hz, 0.0015 g/lbf
3 - 163.5 Hz, 0.0396 g/lbf 4 - 140 Hz, 0.0046 g/lbf
80m 500m

400m
60m 1
2
300m
Amplitude g/lbf

Amplitude g/lbf

3
40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET058 1 - 55 Hz, 0.0017 g/lbf PASS


1 - 190.0 Hz, 0.0249 g/lbf 2 - 70 Hz, 0.0006 g/lbf
2 - 159.5 Hz, 0.0193 g/lbf 3 - 110 Hz, 0.0048 g/lbf
3 - 154.5 Hz, 0.0147 g/lbf 4 - 140 Hz, 0.0065 g/lbf
40m 500m

400m
30m
1
300m
Amplitude g/lbf

Amplitude g/lbf

20m 2
3 200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1238 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA059 1 - 55 Hz, 0.0011 g/lbf PASS


1 - 123.0 Hz, 0.0177 g/lbf 2 - 70 Hz, 0.0008 g/lbf
2 - 155.5 Hz, 0.0134 g/lbf 3 - 110 Hz, 0.0075 g/lbf
3 - 160.0 Hz, 0.0129 g/lbf 4 - 140 Hz, 0.0026 g/lbf
20m 500m
1

400m
15m
23
300m
Amplitude g/lbf

Amplitude g/lbf
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER059 1 - 55 Hz, 0.0037 g/lbf PASS


1 - 98.0 Hz, 0.0538 g/lbf 2 - 70 Hz, 0.0043 g/lbf
2 - 163.5 Hz, 0.0495 g/lbf 3 - 110 Hz, 0.0018 g/lbf
3 - 66.0 Hz, 0.0482 g/lbf 4 - 140 Hz, 0.0045 g/lbf
80m 500m

400m
60m
1
3 2
300m
Amplitude g/lbf

Amplitude g/lbf

40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET059 1 - 55 Hz, 0.0013 g/lbf PASS


1 - 190.0 Hz, 0.0252 g/lbf 2 - 70 Hz, 0.0007 g/lbf
2 - 160.0 Hz, 0.0173 g/lbf 3 - 110 Hz, 0.0047 g/lbf
3 - 154.5 Hz, 0.0132 g/lbf 4 - 140 Hz, 0.0056 g/lbf
40m 500m

400m
30m
1
300m
Amplitude g/lbf

Amplitude g/lbf

20m 2
3 200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1239 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA060 1 - 55 Hz, 0.0011 g/lbf PASS


1 - 123.0 Hz, 0.0195 g/lbf 2 - 70 Hz, 0.0009 g/lbf
2 - 190.0 Hz, 0.0153 g/lbf 3 - 110 Hz, 0.0080 g/lbf
3 - 160.0 Hz, 0.0148 g/lbf 1 4 - 140 Hz, 0.0028 g/lbf
20m 500m

3 2 400m
15m

300m
Amplitude g/lbf

Amplitude g/lbf
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER060 1 - 55 Hz, 0.0038 g/lbf PASS


1 - 98.0 Hz, 0.0480 g/lbf 2 - 70 Hz, 0.0040 g/lbf
2 - 163.5 Hz, 0.0466 g/lbf 3 - 110 Hz, 0.0022 g/lbf
3 - 66.0 Hz, 0.0438 g/lbf 4 - 140 Hz, 0.0037 g/lbf
50m 1 500m
2
3
40m 400m

30m 300m
Amplitude g/lbf

Amplitude g/lbf

20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET060 1 - 55 Hz, 0.0019 g/lbf PASS


1 - 190.0 Hz, 0.0331 g/lbf 2 - 70 Hz, 0.0014 g/lbf
2 - 159.5 Hz, 0.0203 g/lbf 3 - 110 Hz, 0.0069 g/lbf
3 - 154.5 Hz, 0.0180 g/lbf 4 - 140 Hz, 0.0094 g/lbf
40m 500m
1
400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf

2
20m 3
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1240 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA061 1 - 55 Hz, 0.0011 g/lbf PASS


1 - 122.5 Hz, 0.0206 g/lbf 2 - 70 Hz, 0.0010 g/lbf
2 - 190.0 Hz, 0.0190 g/lbf 3 - 110 Hz, 0.0078 g/lbf
3 - 160.0 Hz, 0.0113 g/lbf 4 - 140 Hz, 0.0026 g/lbf
40m 500m

400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf
1
20m 2
200m
3
10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER061 1 - 55 Hz, 0.0038 g/lbf PASS


1 - 99.5 Hz, 0.0359 g/lbf 2 - 70 Hz, 0.0040 g/lbf
2 - 98.0 Hz, 0.0350 g/lbf 3 - 110 Hz, 0.0019 g/lbf
3 - 66.0 Hz, 0.0348 g/lbf 4 - 140 Hz, 0.0047 g/lbf
40m 500m
3 21

400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf

20m
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET061 1 - 55 Hz, 0.0022 g/lbf PASS


1 - 186.0 Hz, 0.0310 g/lbf 2 - 70 Hz, 0.0014 g/lbf
2 - 191.0 Hz, 0.0252 g/lbf 3 - 110 Hz, 0.0078 g/lbf
3 - 154.0 Hz, 0.0224 g/lbf 4 - 140 Hz, 0.0115 g/lbf
40m 500m

1 400m
30m
2
3 300m
Amplitude g/lbf

Amplitude g/lbf

20m
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1241 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA062 1 - 55 Hz, 0.0012 g/lbf PASS


1 - 123.0 Hz, 0.0230 g/lbf 2 - 70 Hz, 0.0009 g/lbf
2 - 190.5 Hz, 0.0210 g/lbf 3 - 110 Hz, 0.0081 g/lbf
3 - 154.5 Hz, 0.0118 g/lbf 4 - 140 Hz, 0.0026 g/lbf
40m 500m

400m
30m

1 300m
Amplitude g/lbf

Amplitude g/lbf
2
20m
200m
3
10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER062 1 - 55 Hz, 0.0038 g/lbf PASS


1 - 99.5 Hz, 0.0479 g/lbf 2 - 70 Hz, 0.0039 g/lbf
2 - 134.0 Hz, 0.0327 g/lbf 3 - 110 Hz, 0.0019 g/lbf
3 - 65.5 Hz, 0.0323 g/lbf 4 - 140 Hz, 0.0058 g/lbf
50m 1 500m

40m 400m
3 2
30m 300m
Amplitude g/lbf

Amplitude g/lbf

20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET062 1 - 55 Hz, 0.0024 g/lbf PASS


1 - 186.0 Hz, 0.0412 g/lbf 2 - 70 Hz, 0.0021 g/lbf
2 - 154.0 Hz, 0.0298 g/lbf 3 - 110 Hz, 0.0104 g/lbf
3 - 158.0 Hz, 0.0261 g/lbf 4 - 140 Hz, 0.0151 g/lbf
80m 500m

400m
60m

300m
Amplitude g/lbf

Amplitude g/lbf

1
40m
2 200m
3
20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1242 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA063 1 - 55 Hz, 0.0012 g/lbf PASS


1 - 122.5 Hz, 0.0237 g/lbf 2 - 70 Hz, 0.0010 g/lbf
2 - 190.0 Hz, 0.0186 g/lbf 3 - 110 Hz, 0.0086 g/lbf
3 - 154.0 Hz, 0.0125 g/lbf 4 - 140 Hz, 0.0029 g/lbf
40m 500m

400m
30m
1
300m
Amplitude g/lbf

Amplitude g/lbf
20m 2
200m
3
10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER063 1 - 55 Hz, 0.0039 g/lbf PASS


1 - 99.5 Hz, 0.0585 g/lbf 2 - 70 Hz, 0.0037 g/lbf
2 - 65.5 Hz, 0.0342 g/lbf 3 - 110 Hz, 0.0023 g/lbf
3 - 132.0 Hz, 0.0318 g/lbf 4 - 140 Hz, 0.0065 g/lbf
80m 500m

1 400m
60m

300m
Amplitude g/lbf

Amplitude g/lbf

40m 2
3
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET063 1 - 55 Hz, 0.0018 g/lbf PASS


1 - 186.5 Hz, 0.0264 g/lbf 2 - 70 Hz, 0.0014 g/lbf
2 - 154.0 Hz, 0.0201 g/lbf 3 - 110 Hz, 0.0071 g/lbf
3 - 158.0 Hz, 0.0163 g/lbf 4 - 140 Hz, 0.0101 g/lbf
50m 500m

40m 400m

30m 300m
Amplitude g/lbf

Amplitude g/lbf

2
20m 3 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1243 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA064 1 - 55 Hz, 0.0012 g/lbf PASS


1 - 122.5 Hz, 0.0260 g/lbf 2 - 70 Hz, 0.0011 g/lbf
2 - 188.5 Hz, 0.0166 g/lbf 3 - 110 Hz, 0.0092 g/lbf
3 - 154.0 Hz, 0.0148 g/lbf 4 - 140 Hz, 0.0030 g/lbf
40m 500m

400m
30m
1
300m
Amplitude g/lbf

Amplitude g/lbf
20m
2
3 200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER064 1 - 55 Hz, 0.0046 g/lbf PASS


1 - 99.5 Hz, 0.0735 g/lbf 2 - 70 Hz, 0.0036 g/lbf
2 - 132.0 Hz, 0.0472 g/lbf 3 - 110 Hz, 0.0027 g/lbf
3 - 65.5 Hz, 0.0396 g/lbf 4 - 140 Hz, 0.0074 g/lbf
80m 1 500m

400m
60m
2
300m
Amplitude g/lbf

Amplitude g/lbf

3
40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET064 1 - 55 Hz, 0.0027 g/lbf PASS


1 - 187.0 Hz, 0.0424 g/lbf 2 - 70 Hz, 0.0018 g/lbf
2 - 154.0 Hz, 0.0342 g/lbf 3 - 110 Hz, 0.0107 g/lbf
3 - 158.0 Hz, 0.0305 g/lbf 4 - 140 Hz, 0.0144 g/lbf
80m 500m

400m
60m

300m
Amplitude g/lbf

Amplitude g/lbf

1
40m 2
3 200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1244 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA065 1 - 55 Hz, 0.0012 g/lbf PASS


1 - 123.0 Hz, 0.0295 g/lbf 2 - 70 Hz, 0.0015 g/lbf
2 - 154.5 Hz, 0.0216 g/lbf 3 - 110 Hz, 0.0109 g/lbf
3 - 187.5 Hz, 0.0178 g/lbf 4 - 140 Hz, 0.0039 g/lbf
40m 500m

1 400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf
2
20m 3
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER065 1 - 55 Hz, 0.0047 g/lbf PASS


1 - 99.5 Hz, 0.0740 g/lbf 2 - 70 Hz, 0.0034 g/lbf
2 - 132.0 Hz, 0.0560 g/lbf 3 - 110 Hz, 0.0027 g/lbf
3 - 65.5 Hz, 0.0417 g/lbf 4 - 140 Hz, 0.0072 g/lbf
80m 1 500m

400m
60m 2

300m
Amplitude g/lbf

Amplitude g/lbf

3
40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET065 1 - 55 Hz, 0.0025 g/lbf PASS


1 - 186.5 Hz, 0.0393 g/lbf 2 - 70 Hz, 0.0017 g/lbf
2 - 154.0 Hz, 0.0333 g/lbf 3 - 110 Hz, 0.0107 g/lbf
3 - 158.0 Hz, 0.0297 g/lbf 4 - 140 Hz, 0.0138 g/lbf
50m 500m

1
40m 400m
2
3
30m 300m
Amplitude g/lbf

Amplitude g/lbf

20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1245 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA066 1 - 55 Hz, 0.0009 g/lbf PASS


1 - 123.0 Hz, 0.0249 g/lbf 2 - 70 Hz, 0.0011 g/lbf
2 - 187.5 Hz, 0.0148 g/lbf 3 - 110 Hz, 0.0089 g/lbf
3 - 154.0 Hz, 0.0145 g/lbf 4 - 140 Hz, 0.0028 g/lbf
40m 500m

400m
30m
1
300m
Amplitude g/lbf

Amplitude g/lbf
20m
3 2 200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER066 1 - 55 Hz, 0.0049 g/lbf PASS


1 - 99.5 Hz, 0.0663 g/lbf 2 - 70 Hz, 0.0032 g/lbf
2 - 132.0 Hz, 0.0596 g/lbf 3 - 110 Hz, 0.0030 g/lbf
3 - 65.5 Hz, 0.0439 g/lbf 4 - 140 Hz, 0.0069 g/lbf
80m 500m
1
2 400m
60m

300m
Amplitude g/lbf

3
Amplitude g/lbf

40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET066 1 - 55 Hz, 0.0017 g/lbf PASS


1 - 186.5 Hz, 0.0241 g/lbf 2 - 70 Hz, 0.0004 g/lbf
2 - 154.5 Hz, 0.0212 g/lbf 3 - 110 Hz, 0.0065 g/lbf
3 - 158.0 Hz, 0.0203 g/lbf 4 - 140 Hz, 0.0068 g/lbf
40m 500m

400m
30m
1
300m
Amplitude g/lbf

Amplitude g/lbf

23
20m
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1246 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA067 1 - 55 Hz, 0.0012 g/lbf PASS


1 - 122.5 Hz, 0.0254 g/lbf 2 - 70 Hz, 0.0011 g/lbf
2 - 154.0 Hz, 0.0187 g/lbf 3 - 110 Hz, 0.0094 g/lbf
3 - 186.5 Hz, 0.0150 g/lbf 4 - 140 Hz, 0.0032 g/lbf
40m 500m

400m
30m
1
300m
Amplitude g/lbf

Amplitude g/lbf
20m 2
3 200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER067 1 - 55 Hz, 0.0047 g/lbf PASS


1 - 99.5 Hz, 0.0535 g/lbf 2 - 70 Hz, 0.0032 g/lbf
2 - 132.0 Hz, 0.0519 g/lbf 3 - 110 Hz, 0.0026 g/lbf
3 - 65.5 Hz, 0.0427 g/lbf 4 - 140 Hz, 0.0070 g/lbf
80m 500m

400m
60m
1 2
300m
Amplitude g/lbf

Amplitude g/lbf

3
40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET067 1 - 55 Hz, 0.0027 g/lbf PASS


1 - 185.5 Hz, 0.0486 g/lbf 2 - 70 Hz, 0.0016 g/lbf
2 - 190.0 Hz, 0.0376 g/lbf 3 - 110 Hz, 0.0113 g/lbf
3 - 154.0 Hz, 0.0355 g/lbf 4 - 140 Hz, 0.0140 g/lbf
1
50m 500m

40m 2 400m
3

30m 300m
Amplitude g/lbf

Amplitude g/lbf

20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1247 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA068 1 - 55 Hz, 0.0012 g/lbf PASS


1 - 122.5 Hz, 0.0249 g/lbf 2 - 70 Hz, 0.0011 g/lbf
2 - 154.0 Hz, 0.0160 g/lbf 3 - 110 Hz, 0.0090 g/lbf
3 - 186.5 Hz, 0.0155 g/lbf 4 - 140 Hz, 0.0032 g/lbf
40m 500m

400m
30m
1
300m
Amplitude g/lbf

Amplitude g/lbf
20m
2 3
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER068 1 - 55 Hz, 0.0048 g/lbf PASS


1 - 98.0 Hz, 0.0426 g/lbf 2 - 70 Hz, 0.0030 g/lbf
2 - 65.5 Hz, 0.0408 g/lbf 3 - 110 Hz, 0.0027 g/lbf
3 - 132.0 Hz, 0.0393 g/lbf 4 - 140 Hz, 0.0064 g/lbf
80m 500m

400m
60m

300m
Amplitude g/lbf

Amplitude g/lbf

2 1
3
40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET068 1 - 55 Hz, 0.0017 g/lbf PASS


1 - 186.0 Hz, 0.0277 g/lbf 2 - 70 Hz, 0.0009 g/lbf
2 - 190.0 Hz, 0.0245 g/lbf 3 - 110 Hz, 0.0078 g/lbf
3 - 154.5 Hz, 0.0209 g/lbf 4 - 140 Hz, 0.0082 g/lbf
40m 500m

400m
30m 1
2
300m
Amplitude g/lbf

Amplitude g/lbf

3
20m
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1248 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA069 1 - 55 Hz, 0.0017 g/lbf PASS


1 - 122.5 Hz, 0.0246 g/lbf 2 - 70 Hz, 0.0010 g/lbf
2 - 154.0 Hz, 0.0174 g/lbf 3 - 110 Hz, 0.0093 g/lbf
3 - 186.5 Hz, 0.0166 g/lbf 4 - 140 Hz, 0.0038 g/lbf
40m 500m

400m
30m
1
300m
Amplitude g/lbf

Amplitude g/lbf
20m 2 3
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER069 1 - 55 Hz, 0.0051 g/lbf PASS


1 - 98.0 Hz, 0.0525 g/lbf 2 - 70 Hz, 0.0026 g/lbf
2 - 134.0 Hz, 0.0474 g/lbf 3 - 110 Hz, 0.0045 g/lbf
3 - 65.5 Hz, 0.0384 g/lbf 4 - 140 Hz, 0.0066 g/lbf
100m 500m

400m

300m
Amplitude g/lbf

Amplitude g/lbf

1
50m 2
3
200m

100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET069 1 - 55 Hz, 0.0044 g/lbf PASS


1 - 185.0 Hz, 0.0884 g/lbf 2 - 70 Hz, 0.0045 g/lbf
2 - 189.5 Hz, 0.0825 g/lbf 3 - 110 Hz, 0.0200 g/lbf
3 - 163.0 Hz, 0.0608 g/lbf 4 - 140 Hz, 0.0282 g/lbf
200m 500m

400m

300m
Amplitude g/lbf

Amplitude g/lbf

100m 12
200m
3

100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1249 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA070 1 - 55 Hz, 0.0013 g/lbf PASS


1 - 123.0 Hz, 0.0251 g/lbf 2 - 70 Hz, 0.0013 g/lbf
2 - 187.5 Hz, 0.0182 g/lbf 3 - 110 Hz, 0.0093 g/lbf
3 - 154.0 Hz, 0.0123 g/lbf 4 - 140 Hz, 0.0040 g/lbf
40m 500m

400m
30m
1
300m
Amplitude g/lbf

Amplitude g/lbf
20m 2
200m
3
10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER070 1 - 55 Hz, 0.0052 g/lbf PASS


1 - 98.0 Hz, 0.0609 g/lbf 2 - 70 Hz, 0.0029 g/lbf
2 - 134.0 Hz, 0.0533 g/lbf 3 - 110 Hz, 0.0034 g/lbf
3 - 186.0 Hz, 0.0464 g/lbf 4 - 140 Hz, 0.0062 g/lbf
80m 500m

1 400m
60m
2
3 300m
Amplitude g/lbf

Amplitude g/lbf

40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET070 1 - 55 Hz, 0.0024 g/lbf PASS


1 - 187.5 Hz, 0.0347 g/lbf 2 - 70 Hz, 0.0016 g/lbf
2 - 193.0 Hz, 0.0314 g/lbf 3 - 110 Hz, 0.0095 g/lbf
3 - 159.5 Hz, 0.0273 g/lbf 4 - 140 Hz, 0.0114 g/lbf
50m 500m

40m 400m
1
2
30m 300m
Amplitude g/lbf

3
Amplitude g/lbf

20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1250 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA071 1 - 55 Hz, 0.0011 g/lbf PASS


1 - 123.0 Hz, 0.0240 g/lbf 2 - 70 Hz, 0.0010 g/lbf
2 - 187.0 Hz, 0.0159 g/lbf 3 - 110 Hz, 0.0090 g/lbf
3 - 111.0 Hz, 0.0097 g/lbf 4 - 140 Hz, 0.0034 g/lbf
40m 500m

400m
30m
1
300m
Amplitude g/lbf

Amplitude g/lbf
20m
2
200m
3
10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER071 1 - 55 Hz, 0.0050 g/lbf PASS


1 - 98.0 Hz, 0.0611 g/lbf 2 - 70 Hz, 0.0031 g/lbf
2 - 134.0 Hz, 0.0481 g/lbf 3 - 110 Hz, 0.0040 g/lbf
3 - 186.5 Hz, 0.0471 g/lbf 4 - 140 Hz, 0.0073 g/lbf
80m 500m

1 400m
60m
2 3
300m
Amplitude g/lbf

Amplitude g/lbf

40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET071 1 - 55 Hz, 0.0023 g/lbf PASS


1 - 186.0 Hz, 0.0345 g/lbf 2 - 70 Hz, 0.0015 g/lbf
2 - 160.0 Hz, 0.0268 g/lbf 3 - 110 Hz, 0.0091 g/lbf
3 - 155.5 Hz, 0.0237 g/lbf 4 - 140 Hz, 0.0105 g/lbf
50m 500m

40m 400m
1

30m 300m
Amplitude g/lbf

Amplitude g/lbf

2
3
20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1251 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
TURBINE END SERIES LOOP RESPONSES

TEA072 1 - 55 Hz, 0.0010 g/lbf PASS


1 - 122.5 Hz, 0.0269 g/lbf 2 - 70 Hz, 0.0011 g/lbf
2 - 186.0 Hz, 0.0165 g/lbf 3 - 110 Hz, 0.0099 g/lbf
3 - 190.0 Hz, 0.0156 g/lbf 4 - 140 Hz, 0.0033 g/lbf
40m 500m

400m
30m
1
300m
Amplitude g/lbf

Amplitude g/lbf
20m
23
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TER072 1 - 55 Hz, 0.0051 g/lbf PASS


1 - 98.0 Hz, 0.0572 g/lbf 2 - 70 Hz, 0.0032 g/lbf
2 - 134.0 Hz, 0.0398 g/lbf 3 - 110 Hz, 0.0033 g/lbf
3 - 66.0 Hz, 0.0390 g/lbf 4 - 140 Hz, 0.0069 g/lbf
80m 500m

400m
60m 1

300m
Amplitude g/lbf

Amplitude g/lbf

3 2
40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

TET072 1 - 55 Hz, 0.0019 g/lbf PASS


1 - 186.0 Hz, 0.0352 g/lbf 2 - 70 Hz, 0.0012 g/lbf
2 - 160.0 Hz, 0.0257 g/lbf 3 - 110 Hz, 0.0085 g/lbf
3 - 155.5 Hz, 0.0222 g/lbf 4 - 140 Hz, 0.0085 g/lbf
40m 500m
1

400m
30m
2
3 300m
Amplitude g/lbf

Amplitude g/lbf

20m
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1252 of 1653


Bump Test_As Left

GE Power Inspection & Life Extension Services


Endwinding Vibration Test Report

Enclosure 2
Collector End Series Loop Frequency Responses
(Amplitude versus Frequency)

GE Proprietary Information. This document contains proprietary information of the General Electric Company and
may not be used or disclosed to others, except with the written permission of General Electric Company. 8

Page 1253 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA004 1 - 55 Hz, 0.0012 g/lbf PASS


1 - 184.5 Hz, 0.0178 g/lbf 2 - 70 Hz, 0.0026 g/lbf
2 - 125.0 Hz, 0.0114 g/lbf 3 - 110 Hz, 0.0051 g/lbf
3 - 123.0 Hz, 0.0103 g/lbf 4 - 140 Hz, 0.0026 g/lbf
20m 500m
1

400m
15m

2 300m
Amplitude g/lbf

Amplitude g/lbf
3
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER004 1 - 55 Hz, 0.0033 g/lbf PASS


1 - 185.5 Hz, 0.1668 g/lbf 2 - 70 Hz, 0.0077 g/lbf
2 - 177.5 Hz, 0.0704 g/lbf 3 - 110 Hz, 0.0130 g/lbf
3 - 175.0 Hz, 0.0667 g/lbf 4 - 140 Hz, 0.0166 g/lbf
200m 500m
1
400m

300m
Amplitude g/lbf

Amplitude g/lbf

100m
32 200m

100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET004 1 - 55 Hz, 0.0032 g/lbf PASS


1 - 184.0 Hz, 0.0338 g/lbf 2 - 70 Hz, 0.0036 g/lbf
2 - 180.0 Hz, 0.0285 g/lbf 3 - 110 Hz, 0.0162 g/lbf
3 - 174.5 Hz, 0.0255 g/lbf 4 - 140 Hz, 0.0121 g/lbf
40m 500m
1
400m
30m 2
3
300m
Amplitude g/lbf

Amplitude g/lbf

20m
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1254 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA005 1 - 55 Hz, 0.0009 g/lbf PASS


1 - 184.0 Hz, 0.0127 g/lbf 2 - 70 Hz, 0.0021 g/lbf
2 - 199.5 Hz, 0.0081 g/lbf 3 - 110 Hz, 0.0030 g/lbf
3 - 178.0 Hz, 0.0075 g/lbf 4 - 140 Hz, 0.0023 g/lbf
20m 500m

400m
15m
1
300m
Amplitude g/lbf

Amplitude g/lbf
10m
3 200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER005 1 - 55 Hz, 0.0029 g/lbf PASS


1 - 185.5 Hz, 0.1378 g/lbf 2 - 70 Hz, 0.0069 g/lbf
2 - 192.5 Hz, 0.0549 g/lbf 3 - 110 Hz, 0.0120 g/lbf
3 - 177.5 Hz, 0.0504 g/lbf 4 - 140 Hz, 0.0132 g/lbf
200m 500m

400m
1

300m
Amplitude g/lbf

Amplitude g/lbf

100m
200m
3 2

100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET005 1 - 55 Hz, 0.0012 g/lbf PASS


1 - 198.5 Hz, 0.0284 g/lbf 2 - 70 Hz, 0.0007 g/lbf
2 - 186.5 Hz, 0.0227 g/lbf 3 - 110 Hz, 0.0046 g/lbf
3 - 180.0 Hz, 0.0192 g/lbf 4 - 140 Hz, 0.0085 g/lbf
40m 500m

400m
30m

2 300m
Amplitude g/lbf

Amplitude g/lbf

20m 3

200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1255 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA006 1 - 55 Hz, 0.0008 g/lbf PASS


1 - 199.0 Hz, 0.0115 g/lbf 2 - 70 Hz, 0.0017 g/lbf
2 - 183.5 Hz, 0.0074 g/lbf 3 - 110 Hz, 0.0023 g/lbf
3 - 169.5 Hz, 0.0065 g/lbf 4 - 140 Hz, 0.0047 g/lbf
20m 500m

400m
15m

300m
Amplitude g/lbf

Amplitude g/lbf
10m
2 200m
3
5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER006 1 - 55 Hz, 0.0022 g/lbf PASS


1 - 186.0 Hz, 0.0614 g/lbf 2 - 70 Hz, 0.0059 g/lbf
2 - 178.0 Hz, 0.0191 g/lbf 3 - 110 Hz, 0.0089 g/lbf
3 - 175.5 Hz, 0.0173 g/lbf 4 - 140 Hz, 0.0059 g/lbf
80m 500m

1 400m
60m

300m
Amplitude g/lbf

Amplitude g/lbf

40m
200m

20m 32
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET006 1 - 55 Hz, 0.0019 g/lbf PASS


1 - 169.0 Hz, 0.0248 g/lbf 2 - 70 Hz, 0.0013 g/lbf
2 - 170.0 Hz, 0.0223 g/lbf 3 - 110 Hz, 0.0085 g/lbf
3 - 185.0 Hz, 0.0216 g/lbf 4 - 140 Hz, 0.0078 g/lbf
40m 500m

400m
30m
1
2 300m
Amplitude g/lbf

Amplitude g/lbf

3
20m
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1256 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA007 1 - 55 Hz, 0.0007 g/lbf PASS


1 - 199.0 Hz, 0.0145 g/lbf 2 - 70 Hz, 0.0013 g/lbf
2 - 198.0 Hz, 0.0144 g/lbf 3 - 110 Hz, 0.0032 g/lbf
3 - 197.0 Hz, 0.0134 g/lbf 4 - 140 Hz, 0.0085 g/lbf
20m 500m

400m
15m 2
3
300m
Amplitude g/lbf

Amplitude g/lbf
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER007 1 - 55 Hz, 0.0021 g/lbf PASS


1 - 186.0 Hz, 0.0257 g/lbf 2 - 70 Hz, 0.0060 g/lbf
2 - 99.0 Hz, 0.0191 g/lbf 3 - 110 Hz, 0.0099 g/lbf
3 - 115.5 Hz, 0.0164 g/lbf 4 - 140 Hz, 0.0051 g/lbf
40m 500m

400m
30m
1
300m
Amplitude g/lbf

Amplitude g/lbf

20m 2
3
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET007 1 - 55 Hz, 0.0018 g/lbf PASS


1 - 176.0 Hz, 0.0147 g/lbf 2 - 70 Hz, 0.0012 g/lbf
2 - 193.0 Hz, 0.0146 g/lbf 3 - 110 Hz, 0.0108 g/lbf
3 - 186.0 Hz, 0.0145 g/lbf 4 - 140 Hz, 0.0088 g/lbf
20m 500m

1 32 400m
15m

300m
Amplitude g/lbf

Amplitude g/lbf

10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1257 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA008 1 - 55 Hz, 0.0007 g/lbf PASS


1 - 198.5 Hz, 0.0126 g/lbf 2 - 70 Hz, 0.0009 g/lbf
2 - 140.5 Hz, 0.0103 g/lbf 3 - 110 Hz, 0.0027 g/lbf
3 - 169.5 Hz, 0.0098 g/lbf 4 - 140 Hz, 0.0101 g/lbf
20m 500m

400m
15m

300m
Amplitude g/lbf

Amplitude g/lbf
2 3
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER008 1 - 55 Hz, 0.0022 g/lbf PASS


1 - 99.0 Hz, 0.0213 g/lbf 2 - 70 Hz, 0.0063 g/lbf
2 - 115.5 Hz, 0.0170 g/lbf 3 - 110 Hz, 0.0114 g/lbf
3 - 104.0 Hz, 0.0167 g/lbf 4 - 140 Hz, 0.0071 g/lbf
40m 500m

400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf

1
20m
3 2
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET008 1 - 55 Hz, 0.0017 g/lbf PASS


1 - 127.0 Hz, 0.0151 g/lbf 2 - 70 Hz, 0.0013 g/lbf
2 - 125.0 Hz, 0.0125 g/lbf 3 - 110 Hz, 0.0110 g/lbf
3 - 111.5 Hz, 0.0122 g/lbf 4 - 140 Hz, 0.0087 g/lbf
20m 500m

1 400m
15m
3 2
300m
Amplitude g/lbf

Amplitude g/lbf

10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1258 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA009 1 - 55 Hz, 0.0008 g/lbf PASS


1 - 199.0 Hz, 0.0142 g/lbf 2 - 70 Hz, 0.0013 g/lbf
2 - 140.0 Hz, 0.0111 g/lbf 3 - 110 Hz, 0.0032 g/lbf
3 - 169.5 Hz, 0.0096 g/lbf 4 - 140 Hz, 0.0111 g/lbf
20m 500m

400m
15m

2 300m
Amplitude g/lbf

Amplitude g/lbf
10m 3

200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER009 1 - 55 Hz, 0.0023 g/lbf PASS


1 - 99.0 Hz, 0.0231 g/lbf 2 - 70 Hz, 0.0064 g/lbf
2 - 126.5 Hz, 0.0200 g/lbf 3 - 110 Hz, 0.0123 g/lbf
3 - 125.5 Hz, 0.0186 g/lbf 4 - 140 Hz, 0.0089 g/lbf
40m 500m

400m
30m

1 300m
Amplitude g/lbf

Amplitude g/lbf

2
20m 3
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET009 1 - 55 Hz, 0.0016 g/lbf PASS


1 - 127.5 Hz, 0.0164 g/lbf 2 - 70 Hz, 0.0015 g/lbf
2 - 112.0 Hz, 0.0134 g/lbf 3 - 110 Hz, 0.0116 g/lbf
3 - 118.0 Hz, 0.0131 g/lbf 4 - 140 Hz, 0.0082 g/lbf
40m 500m

400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf

20m
1
23 200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1259 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA010 1 - 55 Hz, 0.0010 g/lbf PASS


1 - 140.5 Hz, 0.0126 g/lbf 2 - 70 Hz, 0.0017 g/lbf
2 - 144.0 Hz, 0.0112 g/lbf 3 - 110 Hz, 0.0037 g/lbf
3 - 187.0 Hz, 0.0081 g/lbf 4 - 140 Hz, 0.0121 g/lbf
20m 500m

400m
15m
1
2 300m
Amplitude g/lbf

Amplitude g/lbf
10m
3
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER010 1 - 55 Hz, 0.0024 g/lbf PASS


1 - 99.0 Hz, 0.0237 g/lbf 2 - 70 Hz, 0.0065 g/lbf
2 - 125.5 Hz, 0.0228 g/lbf 3 - 110 Hz, 0.0120 g/lbf
3 - 127.0 Hz, 0.0228 g/lbf 4 - 140 Hz, 0.0098 g/lbf
40m 500m

400m
30m
1 23 300m
Amplitude g/lbf

Amplitude g/lbf

20m
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET010 1 - 55 Hz, 0.0012 g/lbf PASS


1 - 127.5 Hz, 0.0139 g/lbf 2 - 70 Hz, 0.0012 g/lbf
2 - 112.0 Hz, 0.0119 g/lbf 3 - 110 Hz, 0.0103 g/lbf
3 - 118.0 Hz, 0.0113 g/lbf 4 - 140 Hz, 0.0063 g/lbf
20m 500m

400m
15m 1
23
300m
Amplitude g/lbf

Amplitude g/lbf

10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1260 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA011 1 - 55 Hz, 0.0011 g/lbf PASS


1 - 140.5 Hz, 0.0161 g/lbf 2 - 70 Hz, 0.0020 g/lbf
2 - 144.0 Hz, 0.0139 g/lbf 3 - 110 Hz, 0.0053 g/lbf
3 - 187.0 Hz, 0.0135 g/lbf 4 - 140 Hz, 0.0152 g/lbf
20m 500m

1
400m
15m 2 3
300m
Amplitude g/lbf

Amplitude g/lbf
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER011 1 - 55 Hz, 0.0027 g/lbf PASS


1 - 186.0 Hz, 0.0604 g/lbf 2 - 70 Hz, 0.0068 g/lbf
2 - 125.5 Hz, 0.0291 g/lbf 3 - 110 Hz, 0.0128 g/lbf
3 - 127.0 Hz, 0.0281 g/lbf 4 - 140 Hz, 0.0099 g/lbf
80m 500m

1 400m
60m

300m
Amplitude g/lbf

Amplitude g/lbf

40m
23 200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET011 1 - 55 Hz, 0.0021 g/lbf PASS


1 - 188.5 Hz, 0.0170 g/lbf 2 - 70 Hz, 0.0026 g/lbf
2 - 127.5 Hz, 0.0161 g/lbf 3 - 110 Hz, 0.0139 g/lbf
3 - 112.0 Hz, 0.0158 g/lbf 4 - 140 Hz, 0.0067 g/lbf
20m 500m
1
3 2
400m
15m

300m
Amplitude g/lbf

Amplitude g/lbf

10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1261 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA012 1 - 55 Hz, 0.0015 g/lbf PASS


1 - 186.0 Hz, 0.0236 g/lbf 2 - 70 Hz, 0.0027 g/lbf
2 - 140.5 Hz, 0.0197 g/lbf 3 - 110 Hz, 0.0088 g/lbf
3 - 144.0 Hz, 0.0164 g/lbf 4 - 140 Hz, 0.0189 g/lbf
40m 500m

400m
30m
1
300m
Amplitude g/lbf

Amplitude g/lbf
2
20m
3
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER012 1 - 55 Hz, 0.0035 g/lbf PASS


1 - 185.5 Hz, 0.1062 g/lbf 2 - 70 Hz, 0.0085 g/lbf
2 - 192.0 Hz, 0.0389 g/lbf 3 - 110 Hz, 0.0156 g/lbf
3 - 125.5 Hz, 0.0362 g/lbf 4 - 140 Hz, 0.0096 g/lbf
200m 500m

400m

300m
Amplitude g/lbf

Amplitude g/lbf

1
100m
200m

3 2
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET012 1 - 55 Hz, 0.0027 g/lbf PASS


1 - 188.0 Hz, 0.0308 g/lbf 2 - 70 Hz, 0.0037 g/lbf
2 - 198.5 Hz, 0.0270 g/lbf 3 - 110 Hz, 0.0157 g/lbf
3 - 112.0 Hz, 0.0182 g/lbf 4 - 140 Hz, 0.0047 g/lbf
40m 500m

1 400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf

20m 3
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1262 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA016 1 - 55 Hz, 0.0018 g/lbf PASS


1 - 185.0 Hz, 0.0416 g/lbf 2 - 70 Hz, 0.0029 g/lbf
2 - 177.0 Hz, 0.0309 g/lbf 3 - 110 Hz, 0.0053 g/lbf
3 - 169.5 Hz, 0.0236 g/lbf 4 - 140 Hz, 0.0117 g/lbf
50m 500m
1
40m 400m

2
30m 300m
Amplitude g/lbf

Amplitude g/lbf
3
20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER016 1 - 55 Hz, 0.0060 g/lbf PASS


1 - 193.0 Hz, 0.1545 g/lbf 2 - 70 Hz, 0.0148 g/lbf
2 - 189.0 Hz, 0.1529 g/lbf 3 - 110 Hz, 0.0135 g/lbf
3 - 165.0 Hz, 0.0378 g/lbf 4 - 140 Hz, 0.0072 g/lbf
200m 500m

21 400m

300m
Amplitude g/lbf

Amplitude g/lbf

100m
200m

3
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET016 1 - 55 Hz, 0.0020 g/lbf PASS


1 - 189.0 Hz, 0.0517 g/lbf 2 - 70 Hz, 0.0025 g/lbf
2 - 192.5 Hz, 0.0466 g/lbf 3 - 110 Hz, 0.0079 g/lbf
3 - 177.0 Hz, 0.0286 g/lbf 4 - 140 Hz, 0.0087 g/lbf
80m 500m

400m
60m
1
2 300m
Amplitude g/lbf

Amplitude g/lbf

40m
3 200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1263 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA017 1 - 55 Hz, 0.0012 g/lbf PASS


1 - 185.5 Hz, 0.0236 g/lbf 2 - 70 Hz, 0.0022 g/lbf
2 - 177.0 Hz, 0.0155 g/lbf 3 - 110 Hz, 0.0025 g/lbf
3 - 169.5 Hz, 0.0136 g/lbf 4 - 140 Hz, 0.0073 g/lbf
40m 500m

400m
30m
1
300m
Amplitude g/lbf

Amplitude g/lbf
20m
2
3 200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER017 1 - 55 Hz, 0.0044 g/lbf PASS


1 - 193.0 Hz, 0.0787 g/lbf 2 - 70 Hz, 0.0115 g/lbf
2 - 189.5 Hz, 0.0769 g/lbf 3 - 110 Hz, 0.0087 g/lbf
3 - 130.0 Hz, 0.0191 g/lbf 4 - 140 Hz, 0.0056 g/lbf
80m 21 500m

400m
60m

300m
Amplitude g/lbf

Amplitude g/lbf

40m
200m
3
20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET017 1 - 55 Hz, 0.0013 g/lbf PASS


1 - 188.5 Hz, 0.0155 g/lbf 2 - 70 Hz, 0.0013 g/lbf
2 - 192.0 Hz, 0.0131 g/lbf 3 - 110 Hz, 0.0057 g/lbf
3 - 127.0 Hz, 0.0112 g/lbf 4 - 140 Hz, 0.0019 g/lbf
20m 500m

1 400m
15m
2
3 300m
Amplitude g/lbf

Amplitude g/lbf

10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1264 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA018 1 - 55 Hz, 0.0008 g/lbf PASS


1 - 186.0 Hz, 0.0181 g/lbf 2 - 70 Hz, 0.0012 g/lbf
2 - 169.5 Hz, 0.0116 g/lbf 3 - 110 Hz, 0.0027 g/lbf
3 - 176.5 Hz, 0.0113 g/lbf 4 - 140 Hz, 0.0068 g/lbf
20m 500m
1

400m
15m
23 300m
Amplitude g/lbf

Amplitude g/lbf
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER018 1 - 55 Hz, 0.0044 g/lbf PASS


1 - 193.0 Hz, 0.0451 g/lbf 2 - 70 Hz, 0.0117 g/lbf
2 - 189.5 Hz, 0.0424 g/lbf 3 - 110 Hz, 0.0100 g/lbf
3 - 73.0 Hz, 0.0199 g/lbf 4 - 140 Hz, 0.0066 g/lbf
50m 500m
1
2
40m 400m

30m 300m
Amplitude g/lbf

Amplitude g/lbf

3
20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET018 1 - 55 Hz, 0.0014 g/lbf PASS


1 - 126.5 Hz, 0.0152 g/lbf 2 - 70 Hz, 0.0017 g/lbf
2 - 199.5 Hz, 0.0112 g/lbf 3 - 110 Hz, 0.0072 g/lbf
3 - 114.5 Hz, 0.0109 g/lbf 4 - 140 Hz, 0.0024 g/lbf
20m 500m

1 400m
15m

300m
Amplitude g/lbf

3
Amplitude g/lbf

10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1265 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA019 1 - 55 Hz, 0.0007 g/lbf PASS


1 - 185.5 Hz, 0.0118 g/lbf 2 - 70 Hz, 0.0009 g/lbf
2 - 169.5 Hz, 0.0101 g/lbf 3 - 110 Hz, 0.0034 g/lbf
3 - 167.5 Hz, 0.0092 g/lbf 4 - 140 Hz, 0.0065 g/lbf
20m 500m

400m
15m
1
300m
Amplitude g/lbf

Amplitude g/lbf
2
10m 3
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER019 1 - 55 Hz, 0.0041 g/lbf PASS


1 - 73.0 Hz, 0.0192 g/lbf 2 - 70 Hz, 0.0109 g/lbf
2 - 118.0 Hz, 0.0181 g/lbf 3 - 110 Hz, 0.0100 g/lbf
3 - 88.0 Hz, 0.0171 g/lbf 4 - 140 Hz, 0.0072 g/lbf
20m 1 500m
2
3
400m
15m

300m
Amplitude g/lbf

Amplitude g/lbf

10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET019 1 - 55 Hz, 0.0011 g/lbf PASS


1 - 127.0 Hz, 0.0145 g/lbf 2 - 70 Hz, 0.0014 g/lbf
2 - 129.5 Hz, 0.0132 g/lbf 3 - 110 Hz, 0.0060 g/lbf
3 - 122.0 Hz, 0.0105 g/lbf 4 - 140 Hz, 0.0021 g/lbf
20m 500m

1 400m
15m
2
300m
Amplitude g/lbf

Amplitude g/lbf

3
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1266 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA020 1 - 55 Hz, 0.0006 g/lbf PASS


1 - 169.5 Hz, 0.0089 g/lbf 2 - 70 Hz, 0.0007 g/lbf
2 - 185.5 Hz, 0.0085 g/lbf 3 - 110 Hz, 0.0037 g/lbf
3 - 167.5 Hz, 0.0082 g/lbf 4 - 140 Hz, 0.0060 g/lbf
40m 500m

400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf
20m
200m

10m 31 2
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER020 1 - 55 Hz, 0.0041 g/lbf PASS


1 - 118.0 Hz, 0.0245 g/lbf 2 - 70 Hz, 0.0102 g/lbf
2 - 88.0 Hz, 0.0179 g/lbf 3 - 110 Hz, 0.0107 g/lbf
3 - 128.0 Hz, 0.0174 g/lbf 4 - 140 Hz, 0.0077 g/lbf
40m 500m

400m
30m
1
300m
Amplitude g/lbf

Amplitude g/lbf

20m 2 3
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET020 1 - 55 Hz, 0.0015 g/lbf PASS


1 - 127.0 Hz, 0.0165 g/lbf 2 - 70 Hz, 0.0022 g/lbf
2 - 129.5 Hz, 0.0155 g/lbf 3 - 110 Hz, 0.0067 g/lbf
3 - 199.5 Hz, 0.0147 g/lbf 4 - 140 Hz, 0.0024 g/lbf
20m 500m
1
2 400m
15m

300m
Amplitude g/lbf

Amplitude g/lbf

10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1267 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA021 1 - 55 Hz, 0.0007 g/lbf PASS


1 - 121.5 Hz, 0.0081 g/lbf 2 - 70 Hz, 0.0011 g/lbf
2 - 170.0 Hz, 0.0073 g/lbf 3 - 110 Hz, 0.0050 g/lbf
3 - 137.5 Hz, 0.0071 g/lbf 4 - 140 Hz, 0.0054 g/lbf
20m 500m

400m
15m

300m
Amplitude g/lbf

Amplitude g/lbf
10m
1
3 2 200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER021 1 - 55 Hz, 0.0040 g/lbf PASS


1 - 118.0 Hz, 0.0234 g/lbf 2 - 70 Hz, 0.0103 g/lbf
2 - 73.0 Hz, 0.0188 g/lbf 3 - 110 Hz, 0.0112 g/lbf
3 - 88.0 Hz, 0.0181 g/lbf 4 - 140 Hz, 0.0076 g/lbf
40m 500m

400m
30m
1
300m
Amplitude g/lbf

Amplitude g/lbf

20m 2 3
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET021 1 - 55 Hz, 0.0017 g/lbf PASS


1 - 126.5 Hz, 0.0173 g/lbf 2 - 70 Hz, 0.0029 g/lbf
2 - 129.0 Hz, 0.0169 g/lbf 3 - 110 Hz, 0.0070 g/lbf
3 - 122.0 Hz, 0.0125 g/lbf 4 - 140 Hz, 0.0027 g/lbf
20m 500m
12
400m
15m
3
300m
Amplitude g/lbf

Amplitude g/lbf

10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1268 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA022 1 - 55 Hz, 0.0008 g/lbf PASS


1 - 121.5 Hz, 0.0087 g/lbf 2 - 70 Hz, 0.0013 g/lbf
2 - 127.0 Hz, 0.0082 g/lbf 3 - 110 Hz, 0.0052 g/lbf
3 - 115.0 Hz, 0.0068 g/lbf 4 - 140 Hz, 0.0045 g/lbf
50m 500m

40m 400m

30m 300m
Amplitude g/lbf

Amplitude g/lbf
20m 200m

1
10m 3 2 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER022 1 - 55 Hz, 0.0036 g/lbf PASS


1 - 193.0 Hz, 0.0302 g/lbf 2 - 70 Hz, 0.0085 g/lbf
2 - 189.0 Hz, 0.0252 g/lbf 3 - 110 Hz, 0.0108 g/lbf
3 - 118.0 Hz, 0.0252 g/lbf 4 - 140 Hz, 0.0059 g/lbf
40m 500m

1 400m
30m
3 2
300m
Amplitude g/lbf

Amplitude g/lbf

20m
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET022 1 - 55 Hz, 0.0030 g/lbf PASS


1 - 192.5 Hz, 0.0243 g/lbf 2 - 70 Hz, 0.0055 g/lbf
2 - 189.5 Hz, 0.0229 g/lbf 3 - 110 Hz, 0.0090 g/lbf
3 - 179.0 Hz, 0.0192 g/lbf 4 - 140 Hz, 0.0031 g/lbf
40m 500m

400m
30m
1
2 300m
Amplitude g/lbf

Amplitude g/lbf

20m 3

200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1269 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA023 1 - 55 Hz, 0.0010 g/lbf PASS


1 - 127.0 Hz, 0.0121 g/lbf 2 - 70 Hz, 0.0017 g/lbf
2 - 121.5 Hz, 0.0112 g/lbf 3 - 110 Hz, 0.0069 g/lbf
3 - 115.0 Hz, 0.0091 g/lbf 4 - 140 Hz, 0.0052 g/lbf
20m 500m

400m
15m
1
2 300m
Amplitude g/lbf

Amplitude g/lbf
10m 3
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER023 1 - 55 Hz, 0.0041 g/lbf PASS


1 - 193.0 Hz, 0.0773 g/lbf 2 - 70 Hz, 0.0089 g/lbf
2 - 189.0 Hz, 0.0704 g/lbf 3 - 110 Hz, 0.0152 g/lbf
3 - 186.5 Hz, 0.0653 g/lbf 4 - 140 Hz, 0.0045 g/lbf
80m 1
500m
2
3
400m
60m

300m
Amplitude g/lbf

Amplitude g/lbf

40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET023 1 - 55 Hz, 0.0029 g/lbf PASS


1 - 129.0 Hz, 0.0241 g/lbf 2 - 70 Hz, 0.0059 g/lbf
2 - 195.0 Hz, 0.0232 g/lbf 3 - 110 Hz, 0.0095 g/lbf
3 - 122.0 Hz, 0.0151 g/lbf 4 - 140 Hz, 0.0033 g/lbf
40m 500m

400m
30m
1 2 300m
Amplitude g/lbf

Amplitude g/lbf

20m
3 200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1270 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA024 1 - 55 Hz, 0.0013 g/lbf PASS


1 - 126.5 Hz, 0.0180 g/lbf 2 - 70 Hz, 0.0025 g/lbf
2 - 121.5 Hz, 0.0162 g/lbf 3 - 110 Hz, 0.0104 g/lbf
3 - 114.5 Hz, 0.0135 g/lbf 4 - 140 Hz, 0.0061 g/lbf
20m 500m
1
2
400m
15m 3
300m
Amplitude g/lbf

Amplitude g/lbf
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER024 1 - 55 Hz, 0.0041 g/lbf PASS


1 - 192.5 Hz, 0.1283 g/lbf 2 - 70 Hz, 0.0085 g/lbf
2 - 189.0 Hz, 0.1181 g/lbf 3 - 110 Hz, 0.0181 g/lbf
3 - 118.0 Hz, 0.0327 g/lbf 4 - 140 Hz, 0.0030 g/lbf
200m 500m

400m
1
2
300m
Amplitude g/lbf

Amplitude g/lbf

100m
200m

3 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET024 1 - 55 Hz, 0.0028 g/lbf PASS


1 - 194.0 Hz, 0.0573 g/lbf 2 - 70 Hz, 0.0057 g/lbf
2 - 199.0 Hz, 0.0458 g/lbf 3 - 110 Hz, 0.0092 g/lbf
3 - 189.5 Hz, 0.0384 g/lbf 4 - 140 Hz, 0.0022 g/lbf
80m 500m

400m
60m 1

300m
Amplitude g/lbf

Amplitude g/lbf

40m 3

200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1271 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA028 1 - 55 Hz, 0.0015 g/lbf PASS


1 - 191.5 Hz, 0.0133 g/lbf 2 - 70 Hz, 0.0043 g/lbf
2 - 190.0 Hz, 0.0131 g/lbf 3 - 110 Hz, 0.0052 g/lbf
3 - 179.0 Hz, 0.0103 g/lbf 4 - 140 Hz, 0.0018 g/lbf
20m 500m

400m
15m
21
300m
Amplitude g/lbf

Amplitude g/lbf
3
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER028 1 - 55 Hz, 0.0040 g/lbf PASS


1 - 178.5 Hz, 0.0280 g/lbf 2 - 70 Hz, 0.0128 g/lbf
2 - 79.5 Hz, 0.0228 g/lbf 3 - 110 Hz, 0.0087 g/lbf
3 - 71.5 Hz, 0.0195 g/lbf 4 - 140 Hz, 0.0060 g/lbf
200m 500m

400m

300m
Amplitude g/lbf

Amplitude g/lbf

100m
200m

1 100m
3 2
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET028 1 - 55 Hz, 0.0012 g/lbf PASS


1 - 128.5 Hz, 0.0181 g/lbf 2 - 70 Hz, 0.0015 g/lbf
2 - 198.0 Hz, 0.0176 g/lbf 3 - 110 Hz, 0.0052 g/lbf
3 - 119.0 Hz, 0.0139 g/lbf 4 - 140 Hz, 0.0047 g/lbf
40m 500m

400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf

20m 1 2
3 200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1272 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA029 1 - 55 Hz, 0.0014 g/lbf PASS


1 - 192.0 Hz, 0.0087 g/lbf 2 - 70 Hz, 0.0049 g/lbf
2 - 190.0 Hz, 0.0084 g/lbf 3 - 110 Hz, 0.0038 g/lbf
3 - 199.5 Hz, 0.0080 g/lbf 4 - 140 Hz, 0.0007 g/lbf
10m 500m
1
2
8m 400m

6m 300m
Amplitude g/lbf

Amplitude g/lbf
4m 200m

2m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER029 1 - 55 Hz, 0.0035 g/lbf PASS


1 - 79.5 Hz, 0.0223 g/lbf 2 - 70 Hz, 0.0128 g/lbf
2 - 71.5 Hz, 0.0204 g/lbf 3 - 110 Hz, 0.0071 g/lbf
3 - 178.5 Hz, 0.0147 g/lbf 4 - 140 Hz, 0.0051 g/lbf
200m 500m

400m

300m
Amplitude g/lbf

Amplitude g/lbf

100m
200m

100m
2 1 3
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET029 1 - 55 Hz, 0.0013 g/lbf PASS


1 - 197.5 Hz, 0.0318 g/lbf 2 - 70 Hz, 0.0025 g/lbf
2 - 128.5 Hz, 0.0173 g/lbf 3 - 110 Hz, 0.0043 g/lbf
3 - 189.5 Hz, 0.0138 g/lbf 4 - 140 Hz, 0.0050 g/lbf
40m 500m

400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf

20m 2
3 200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1273 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA030 1 - 55 Hz, 0.0012 g/lbf PASS


1 - 191.5 Hz, 0.0085 g/lbf 2 - 70 Hz, 0.0040 g/lbf
2 - 199.5 Hz, 0.0067 g/lbf 3 - 110 Hz, 0.0036 g/lbf
3 - 71.5 Hz, 0.0063 g/lbf 4 - 140 Hz, 0.0014 g/lbf
10m 500m
1
8m 400m

3
6m 300m
Amplitude g/lbf

Amplitude g/lbf
4m 200m

2m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER030 1 - 55 Hz, 0.0033 g/lbf PASS


1 - 79.5 Hz, 0.0220 g/lbf 2 - 70 Hz, 0.0133 g/lbf
2 - 71.5 Hz, 0.0215 g/lbf 3 - 110 Hz, 0.0071 g/lbf
3 - 127.0 Hz, 0.0130 g/lbf 4 - 140 Hz, 0.0059 g/lbf
80m 500m

400m
60m

300m
Amplitude g/lbf

Amplitude g/lbf

40m
200m
2 1
20m
3 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET030 1 - 55 Hz, 0.0013 g/lbf PASS


1 - 197.5 Hz, 0.0235 g/lbf 2 - 70 Hz, 0.0032 g/lbf
2 - 128.0 Hz, 0.0146 g/lbf 3 - 110 Hz, 0.0038 g/lbf
3 - 123.5 Hz, 0.0115 g/lbf 4 - 140 Hz, 0.0048 g/lbf
40m 500m

400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf

20m
2 200m
3
10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1274 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA031 1 - 55 Hz, 0.0007 g/lbf PASS


1 - 191.5 Hz, 0.0089 g/lbf 2 - 70 Hz, 0.0020 g/lbf
2 - 195.5 Hz, 0.0078 g/lbf 3 - 110 Hz, 0.0036 g/lbf
3 - 169.5 Hz, 0.0067 g/lbf 4 - 140 Hz, 0.0035 g/lbf
10m 500m
1

8m 2 400m
3
6m 300m
Amplitude g/lbf

Amplitude g/lbf
4m 200m

2m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER031 1 - 55 Hz, 0.0034 g/lbf PASS


1 - 71.5 Hz, 0.0230 g/lbf 2 - 70 Hz, 0.0139 g/lbf
2 - 79.5 Hz, 0.0219 g/lbf 3 - 110 Hz, 0.0085 g/lbf
3 - 127.0 Hz, 0.0162 g/lbf 4 - 140 Hz, 0.0077 g/lbf
40m 500m

400m
30m

1 300m
Amplitude g/lbf

2
Amplitude g/lbf

20m
3
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET031 1 - 55 Hz, 0.0006 g/lbf PASS


1 - 192.5 Hz, 0.0083 g/lbf 2 - 70 Hz, 0.0007 g/lbf
2 - 189.0 Hz, 0.0083 g/lbf 3 - 110 Hz, 0.0035 g/lbf
3 - 118.0 Hz, 0.0078 g/lbf 4 - 140 Hz, 0.0024 g/lbf
40m 500m

400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf

20m
200m

10m 3 21
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1275 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA032 1 - 55 Hz, 0.0006 g/lbf PASS


1 - 196.0 Hz, 0.0086 g/lbf 2 - 70 Hz, 0.0012 g/lbf
2 - 192.0 Hz, 0.0085 g/lbf 3 - 110 Hz, 0.0043 g/lbf
3 - 170.0 Hz, 0.0075 g/lbf 4 - 140 Hz, 0.0044 g/lbf
20m 500m

400m
15m

300m
Amplitude g/lbf

Amplitude g/lbf
10m
21
3 200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER032 1 - 55 Hz, 0.0032 g/lbf PASS


1 - 71.5 Hz, 0.0232 g/lbf 2 - 70 Hz, 0.0138 g/lbf
2 - 79.5 Hz, 0.0202 g/lbf 3 - 110 Hz, 0.0081 g/lbf
3 - 127.0 Hz, 0.0169 g/lbf 4 - 140 Hz, 0.0080 g/lbf
40m 500m

400m
30m
1
300m
Amplitude g/lbf

Amplitude g/lbf

2
20m
3
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET032 1 - 55 Hz, 0.0020 g/lbf PASS


1 - 127.5 Hz, 0.0143 g/lbf 2 - 70 Hz, 0.0059 g/lbf
2 - 123.5 Hz, 0.0114 g/lbf 3 - 110 Hz, 0.0044 g/lbf
3 - 71.5 Hz, 0.0095 g/lbf 4 - 140 Hz, 0.0051 g/lbf
20m 500m

400m
15m 1

2 300m
Amplitude g/lbf

Amplitude g/lbf

10m 3
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1276 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA033 1 - 55 Hz, 0.0007 g/lbf PASS


1 - 170.0 Hz, 0.0082 g/lbf 2 - 70 Hz, 0.0017 g/lbf
2 - 133.5 Hz, 0.0079 g/lbf 3 - 110 Hz, 0.0049 g/lbf
3 - 142.5 Hz, 0.0071 g/lbf 4 - 140 Hz, 0.0048 g/lbf
20m 500m

400m
15m

300m
Amplitude g/lbf

Amplitude g/lbf
10m
2 1
3 200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER033 1 - 55 Hz, 0.0031 g/lbf PASS


1 - 71.5 Hz, 0.0231 g/lbf 2 - 70 Hz, 0.0139 g/lbf
2 - 127.0 Hz, 0.0196 g/lbf 3 - 110 Hz, 0.0091 g/lbf
3 - 79.5 Hz, 0.0184 g/lbf 4 - 140 Hz, 0.0084 g/lbf
40m 500m

400m
30m

1 300m
Amplitude g/lbf

Amplitude g/lbf

2
20m 3
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET033 1 - 55 Hz, 0.0005 g/lbf PASS


1 - 118.0 Hz, 0.0110 g/lbf 2 - 70 Hz, 0.0017 g/lbf
2 - 128.5 Hz, 0.0103 g/lbf 3 - 110 Hz, 0.0043 g/lbf
3 - 126.0 Hz, 0.0079 g/lbf 4 - 140 Hz, 0.0030 g/lbf
20m 500m

400m
15m

1 300m
Amplitude g/lbf

Amplitude g/lbf

2
10m
3
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1277 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA034 1 - 55 Hz, 0.0009 g/lbf PASS


1 - 133.5 Hz, 0.0070 g/lbf 2 - 70 Hz, 0.0025 g/lbf
2 - 170.0 Hz, 0.0068 g/lbf 3 - 110 Hz, 0.0051 g/lbf
3 - 143.0 Hz, 0.0067 g/lbf 4 - 140 Hz, 0.0041 g/lbf
8m 500m
1
3 2
400m
6m

300m
Amplitude g/lbf

Amplitude g/lbf
4m
200m

2m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER034 1 - 55 Hz, 0.0031 g/lbf PASS


1 - 71.5 Hz, 0.0219 g/lbf 2 - 70 Hz, 0.0132 g/lbf
2 - 127.0 Hz, 0.0205 g/lbf 3 - 110 Hz, 0.0094 g/lbf
3 - 79.5 Hz, 0.0154 g/lbf 4 - 140 Hz, 0.0071 g/lbf
40m 500m

400m
30m

300m
Amplitude g/lbf

1
Amplitude g/lbf

2
20m
3
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET034 1 - 55 Hz, 0.0023 g/lbf PASS


1 - 197.5 Hz, 0.0405 g/lbf 2 - 70 Hz, 0.0081 g/lbf
2 - 71.5 Hz, 0.0130 g/lbf 3 - 110 Hz, 0.0047 g/lbf
3 - 127.5 Hz, 0.0122 g/lbf 4 - 140 Hz, 0.0033 g/lbf
50m 500m

40m 400m

30m 300m
Amplitude g/lbf

Amplitude g/lbf

20m 200m
2 3
10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1278 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA035 1 - 55 Hz, 0.0010 g/lbf PASS


1 - 119.5 Hz, 0.0088 g/lbf 2 - 70 Hz, 0.0027 g/lbf
2 - 126.0 Hz, 0.0082 g/lbf 3 - 110 Hz, 0.0059 g/lbf
3 - 199.5 Hz, 0.0081 g/lbf 4 - 140 Hz, 0.0046 g/lbf
80m 500m

400m
60m

300m
Amplitude g/lbf

Amplitude g/lbf
40m
200m

20m
100m
12
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER035 1 - 55 Hz, 0.0028 g/lbf PASS


1 - 126.5 Hz, 0.0203 g/lbf 2 - 70 Hz, 0.0120 g/lbf
2 - 71.5 Hz, 0.0198 g/lbf 3 - 110 Hz, 0.0089 g/lbf
3 - 129.5 Hz, 0.0185 g/lbf 4 - 140 Hz, 0.0057 g/lbf
80m 500m

400m
60m

300m
Amplitude g/lbf

Amplitude g/lbf

40m
200m
2 13
20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET035 1 - 55 Hz, 0.0006 g/lbf PASS


1 - 198.0 Hz, 0.0333 g/lbf 2 - 70 Hz, 0.0019 g/lbf
2 - 117.5 Hz, 0.0098 g/lbf 3 - 110 Hz, 0.0032 g/lbf
3 - 128.5 Hz, 0.0082 g/lbf 4 - 140 Hz, 0.0027 g/lbf
50m 500m

40m 400m

30m 300m
Amplitude g/lbf

Amplitude g/lbf

20m 200m

2 3
10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1279 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA036 1 - 55 Hz, 0.0012 g/lbf PASS


1 - 119.5 Hz, 0.0129 g/lbf 2 - 70 Hz, 0.0028 g/lbf
2 - 126.0 Hz, 0.0123 g/lbf 3 - 110 Hz, 0.0082 g/lbf
3 - 123.5 Hz, 0.0102 g/lbf 4 - 140 Hz, 0.0062 g/lbf
20m 500m

400m
15m
12
300m
Amplitude g/lbf

Amplitude g/lbf
3
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER036 1 - 55 Hz, 0.0028 g/lbf PASS


1 - 197.5 Hz, 0.0869 g/lbf 2 - 70 Hz, 0.0111 g/lbf
2 - 126.5 Hz, 0.0224 g/lbf 3 - 110 Hz, 0.0094 g/lbf
3 - 129.5 Hz, 0.0203 g/lbf 4 - 140 Hz, 0.0038 g/lbf
100m 500m

400m

300m
Amplitude g/lbf

Amplitude g/lbf

50m
200m

23
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET036 1 - 55 Hz, 0.0037 g/lbf PASS


1 - 197.5 Hz, 0.1129 g/lbf 2 - 70 Hz, 0.0127 g/lbf
2 - 178.5 Hz, 0.0244 g/lbf 3 - 110 Hz, 0.0094 g/lbf
3 - 127.5 Hz, 0.0200 g/lbf 4 - 140 Hz, 0.0031 g/lbf
200m 500m

400m

300m
Amplitude g/lbf

Amplitude g/lbf

100m
200m

100m
3 2
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1280 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA040 1 - 55 Hz, 0.0015 g/lbf PASS


1 - 197.0 Hz, 0.0273 g/lbf 2 - 70 Hz, 0.0031 g/lbf
2 - 184.0 Hz, 0.0142 g/lbf 3 - 110 Hz, 0.0060 g/lbf
3 - 176.5 Hz, 0.0141 g/lbf 4 - 140 Hz, 0.0052 g/lbf
100m 500m

400m

300m
Amplitude g/lbf

Amplitude g/lbf
50m
200m
1

32 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER040 1 - 55 Hz, 0.0042 g/lbf PASS


1 - 191.0 Hz, 0.0494 g/lbf 2 - 70 Hz, 0.0118 g/lbf
2 - 183.5 Hz, 0.0344 g/lbf 3 - 110 Hz, 0.0071 g/lbf
3 - 176.0 Hz, 0.0337 g/lbf 4 - 140 Hz, 0.0029 g/lbf
200m 500m

400m

300m
Amplitude g/lbf

Amplitude g/lbf

100m
200m
1
3 2 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET040 1 - 55 Hz, 0.0012 g/lbf PASS


1 - 120.0 Hz, 0.0176 g/lbf 2 - 70 Hz, 0.0057 g/lbf
2 - 116.0 Hz, 0.0129 g/lbf 3 - 110 Hz, 0.0069 g/lbf
3 - 184.5 Hz, 0.0111 g/lbf 4 - 140 Hz, 0.0027 g/lbf
20m 500m
1

400m
15m
2
3 300m
Amplitude g/lbf

Amplitude g/lbf

10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1281 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA041 1 - 55 Hz, 0.0010 g/lbf PASS


1 - 197.0 Hz, 0.0168 g/lbf 2 - 70 Hz, 0.0020 g/lbf
2 - 190.5 Hz, 0.0113 g/lbf 3 - 110 Hz, 0.0048 g/lbf
3 - 176.5 Hz, 0.0091 g/lbf 4 - 140 Hz, 0.0033 g/lbf
20m 500m
1
400m
15m

2 300m
Amplitude g/lbf

Amplitude g/lbf
10m 3
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER041 1 - 55 Hz, 0.0038 g/lbf PASS


1 - 191.0 Hz, 0.0284 g/lbf 2 - 70 Hz, 0.0107 g/lbf
2 - 183.5 Hz, 0.0189 g/lbf 3 - 110 Hz, 0.0053 g/lbf
3 - 176.5 Hz, 0.0185 g/lbf 4 - 140 Hz, 0.0024 g/lbf
100m 500m

400m

300m
Amplitude g/lbf

Amplitude g/lbf

50m
200m
1
32
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET041 1 - 55 Hz, 0.0011 g/lbf PASS


1 - 196.5 Hz, 0.0223 g/lbf 2 - 70 Hz, 0.0011 g/lbf
2 - 187.5 Hz, 0.0170 g/lbf 3 - 110 Hz, 0.0057 g/lbf
3 - 178.5 Hz, 0.0134 g/lbf 4 - 140 Hz, 0.0052 g/lbf
40m 500m

400m
30m

1 300m
Amplitude g/lbf

Amplitude g/lbf

20m 2
3 200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1282 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA042 1 - 55 Hz, 0.0010 g/lbf PASS


1 - 197.5 Hz, 0.0131 g/lbf 2 - 70 Hz, 0.0020 g/lbf
2 - 191.5 Hz, 0.0090 g/lbf 3 - 110 Hz, 0.0039 g/lbf
3 - 190.5 Hz, 0.0088 g/lbf 4 - 140 Hz, 0.0028 g/lbf
20m 500m

400m
15m

300m
Amplitude g/lbf

Amplitude g/lbf
10m 32
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER042 1 - 55 Hz, 0.0038 g/lbf PASS


1 - 91.5 Hz, 0.0207 g/lbf 2 - 70 Hz, 0.0100 g/lbf
2 - 73.0 Hz, 0.0162 g/lbf 3 - 110 Hz, 0.0061 g/lbf
3 - 122.0 Hz, 0.0145 g/lbf 4 - 140 Hz, 0.0052 g/lbf
50m 500m

40m 400m

30m 300m
Amplitude g/lbf

Amplitude g/lbf

1
20m 200m
2
3

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET042 1 - 55 Hz, 0.0004 g/lbf PASS


1 - 196.0 Hz, 0.0125 g/lbf 2 - 70 Hz, 0.0010 g/lbf
2 - 187.5 Hz, 0.0096 g/lbf 3 - 110 Hz, 0.0040 g/lbf
3 - 184.0 Hz, 0.0088 g/lbf 4 - 140 Hz, 0.0035 g/lbf
20m 500m

400m
15m
1
300m
Amplitude g/lbf

Amplitude g/lbf

10m 2
3
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1283 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA043 1 - 55 Hz, 0.0006 g/lbf PASS


1 - 197.5 Hz, 0.0124 g/lbf 2 - 70 Hz, 0.0009 g/lbf
2 - 176.5 Hz, 0.0090 g/lbf 3 - 110 Hz, 0.0045 g/lbf
3 - 179.0 Hz, 0.0086 g/lbf 4 - 140 Hz, 0.0032 g/lbf
20m 500m

400m
15m

300m
Amplitude g/lbf

Amplitude g/lbf
10m 23
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER043 1 - 55 Hz, 0.0035 g/lbf PASS


1 - 91.5 Hz, 0.0214 g/lbf 2 - 70 Hz, 0.0090 g/lbf
2 - 73.0 Hz, 0.0145 g/lbf 3 - 110 Hz, 0.0058 g/lbf
3 - 81.5 Hz, 0.0128 g/lbf 4 - 140 Hz, 0.0068 g/lbf
40m 500m

400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf

1
20m
2 200m
3
10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET043 1 - 55 Hz, 0.0012 g/lbf PASS


1 - 120.0 Hz, 0.0154 g/lbf 2 - 70 Hz, 0.0031 g/lbf
2 - 184.5 Hz, 0.0095 g/lbf 3 - 110 Hz, 0.0068 g/lbf
3 - 183.5 Hz, 0.0094 g/lbf 4 - 140 Hz, 0.0025 g/lbf
20m 500m

1 400m
15m

300m
Amplitude g/lbf

Amplitude g/lbf

10m 32
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1284 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA044 1 - 55 Hz, 0.0006 g/lbf PASS


1 - 197.5 Hz, 0.0104 g/lbf 2 - 70 Hz, 0.0008 g/lbf
2 - 176.5 Hz, 0.0084 g/lbf 3 - 110 Hz, 0.0046 g/lbf
3 - 179.0 Hz, 0.0083 g/lbf 4 - 140 Hz, 0.0034 g/lbf
20m 500m

400m
15m

300m
Amplitude g/lbf

Amplitude g/lbf
10m
23
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER044 1 - 55 Hz, 0.0035 g/lbf PASS


1 - 91.5 Hz, 0.0221 g/lbf 2 - 70 Hz, 0.0086 g/lbf
2 - 128.0 Hz, 0.0148 g/lbf 3 - 110 Hz, 0.0064 g/lbf
3 - 126.5 Hz, 0.0147 g/lbf 4 - 140 Hz, 0.0081 g/lbf
40m 500m

400m
30m

1 300m
Amplitude g/lbf

Amplitude g/lbf

20m
32 200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET044 1 - 55 Hz, 0.0002 g/lbf PASS


1 - 199.5 Hz, 0.0110 g/lbf 2 - 70 Hz, 0.0004 g/lbf
2 - 197.5 Hz, 0.0109 g/lbf 3 - 110 Hz, 0.0045 g/lbf
3 - 183.5 Hz, 0.0084 g/lbf 4 - 140 Hz, 0.0032 g/lbf
20m 500m

400m
15m

300m
Amplitude g/lbf

2
Amplitude g/lbf

10m 3
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1285 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA045 1 - 55 Hz, 0.0007 g/lbf PASS


1 - 120.0 Hz, 0.0088 g/lbf 2 - 70 Hz, 0.0012 g/lbf
2 - 198.5 Hz, 0.0081 g/lbf 3 - 110 Hz, 0.0047 g/lbf
3 - 131.5 Hz, 0.0077 g/lbf 4 - 140 Hz, 0.0030 g/lbf
20m 500m

400m
15m

300m
Amplitude g/lbf

Amplitude g/lbf
10m 1
3 200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER045 1 - 55 Hz, 0.0034 g/lbf PASS


1 - 91.5 Hz, 0.0207 g/lbf 2 - 70 Hz, 0.0077 g/lbf
2 - 128.0 Hz, 0.0179 g/lbf 3 - 110 Hz, 0.0065 g/lbf
3 - 126.5 Hz, 0.0178 g/lbf 4 - 140 Hz, 0.0084 g/lbf
40m 500m

400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf

1
20m 32
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET045 1 - 55 Hz, 0.0002 g/lbf PASS


1 - 199.5 Hz, 0.0122 g/lbf 2 - 70 Hz, 0.0003 g/lbf
2 - 182.5 Hz, 0.0091 g/lbf 3 - 110 Hz, 0.0050 g/lbf
3 - 188.0 Hz, 0.0083 g/lbf 4 - 140 Hz, 0.0039 g/lbf
20m 500m

400m
15m

300m
Amplitude g/lbf

Amplitude g/lbf

10m 2
3
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1286 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA046 1 - 55 Hz, 0.0008 g/lbf PASS


1 - 120.0 Hz, 0.0130 g/lbf 2 - 70 Hz, 0.0016 g/lbf
2 - 132.0 Hz, 0.0094 g/lbf 3 - 110 Hz, 0.0063 g/lbf
3 - 182.5 Hz, 0.0079 g/lbf 4 - 140 Hz, 0.0034 g/lbf
20m 500m

400m
15m
1
300m
Amplitude g/lbf

Amplitude g/lbf
10m 2
3
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER046 1 - 55 Hz, 0.0034 g/lbf PASS


1 - 126.5 Hz, 0.0213 g/lbf 2 - 70 Hz, 0.0073 g/lbf
2 - 127.5 Hz, 0.0213 g/lbf 3 - 110 Hz, 0.0069 g/lbf
3 - 130.0 Hz, 0.0202 g/lbf 4 - 140 Hz, 0.0082 g/lbf
40m 500m

400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf

123
20m
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET046 1 - 55 Hz, 0.0004 g/lbf PASS


1 - 181.5 Hz, 0.0079 g/lbf 2 - 70 Hz, 0.0013 g/lbf
2 - 182.5 Hz, 0.0079 g/lbf 3 - 110 Hz, 0.0049 g/lbf
3 - 119.5 Hz, 0.0078 g/lbf 3 4 - 140 Hz, 0.0036 g/lbf
8m 500m

400m
6m

300m
Amplitude g/lbf

Amplitude g/lbf

4m
200m

2m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1287 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA047 1 - 55 Hz, 0.0011 g/lbf PASS


1 - 120.0 Hz, 0.0149 g/lbf 2 - 70 Hz, 0.0022 g/lbf
2 - 131.5 Hz, 0.0113 g/lbf 3 - 110 Hz, 0.0058 g/lbf
3 - 182.5 Hz, 0.0088 g/lbf 4 - 140 Hz, 0.0029 g/lbf
50m 500m

40m 400m

30m 300m
Amplitude g/lbf

Amplitude g/lbf
20m 200m
1
2
10m 3 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER047 1 - 55 Hz, 0.0032 g/lbf PASS


1 - 126.5 Hz, 0.0252 g/lbf 2 - 70 Hz, 0.0068 g/lbf
2 - 127.5 Hz, 0.0251 g/lbf 3 - 110 Hz, 0.0074 g/lbf
3 - 130.0 Hz, 0.0229 g/lbf 4 - 140 Hz, 0.0076 g/lbf
80m 500m

400m
60m

300m
Amplitude g/lbf

Amplitude g/lbf

40m
200m
12
3
20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET047 1 - 55 Hz, 0.0029 g/lbf PASS


1 - 120.0 Hz, 0.0238 g/lbf 2 - 70 Hz, 0.0096 g/lbf
2 - 116.0 Hz, 0.0175 g/lbf 3 - 110 Hz, 0.0094 g/lbf
3 - 71.5 Hz, 0.0148 g/lbf 4 - 140 Hz, 0.0029 g/lbf
40m 500m

400m
30m
1
300m
Amplitude g/lbf

Amplitude g/lbf

20m 2
3 200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1288 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA048 1 - 55 Hz, 0.0015 g/lbf PASS


1 - 120.0 Hz, 0.0247 g/lbf 2 - 70 Hz, 0.0028 g/lbf
2 - 131.5 Hz, 0.0153 g/lbf 3 - 110 Hz, 0.0099 g/lbf
3 - 182.5 Hz, 0.0136 g/lbf 4 - 140 Hz, 0.0045 g/lbf
40m 500m

400m
30m
1
300m
Amplitude g/lbf

Amplitude g/lbf
20m
2 200m
3

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER048 1 - 55 Hz, 0.0031 g/lbf PASS


1 - 126.0 Hz, 0.0290 g/lbf 2 - 70 Hz, 0.0062 g/lbf
2 - 130.0 Hz, 0.0237 g/lbf 3 - 110 Hz, 0.0088 g/lbf
3 - 123.5 Hz, 0.0224 g/lbf 4 - 140 Hz, 0.0061 g/lbf
200m 500m

400m

300m
Amplitude g/lbf

Amplitude g/lbf

100m
200m

1 100m
32
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET048 1 - 55 Hz, 0.0033 g/lbf PASS


1 - 190.5 Hz, 0.0175 g/lbf 2 - 70 Hz, 0.0070 g/lbf
2 - 188.5 Hz, 0.0173 g/lbf 3 - 110 Hz, 0.0044 g/lbf
3 - 91.5 Hz, 0.0138 g/lbf 4 - 140 Hz, 0.0014 g/lbf
50m 500m

40m 400m

30m 300m
Amplitude g/lbf

Amplitude g/lbf

20m 21 200m
3
10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1289 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA052 1 - 55 Hz, 0.0016 g/lbf PASS


1 - 179.5 Hz, 0.0111 g/lbf 2 - 70 Hz, 0.0042 g/lbf
2 - 174.0 Hz, 0.0110 g/lbf 3 - 110 Hz, 0.0055 g/lbf
3 - 176.5 Hz, 0.0108 g/lbf 4 - 140 Hz, 0.0046 g/lbf
40m 500m

400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf
20m
200m
231
10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER052 1 - 55 Hz, 0.0044 g/lbf PASS


1 - 188.5 Hz, 0.1034 g/lbf 2 - 70 Hz, 0.0172 g/lbf
2 - 192.0 Hz, 0.0696 g/lbf 3 - 110 Hz, 0.0071 g/lbf
3 - 195.5 Hz, 0.0590 g/lbf 4 - 140 Hz, 0.0073 g/lbf
200m 500m

400m

300m
Amplitude g/lbf

Amplitude g/lbf

1
100m
2 200m
3

100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET052 1 - 55 Hz, 0.0019 g/lbf PASS


1 - 188.0 Hz, 0.0408 g/lbf 2 - 70 Hz, 0.0066 g/lbf
2 - 184.0 Hz, 0.0346 g/lbf 3 - 110 Hz, 0.0049 g/lbf
3 - 195.5 Hz, 0.0313 g/lbf 4 - 140 Hz, 0.0075 g/lbf
50m 500m
1
40m 400m
2
3
30m 300m
Amplitude g/lbf

Amplitude g/lbf

20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1290 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA053 1 - 55 Hz, 0.0012 g/lbf PASS


1 - 199.5 Hz, 0.0205 g/lbf 2 - 70 Hz, 0.0043 g/lbf
2 - 71.5 Hz, 0.0068 g/lbf 3 - 110 Hz, 0.0027 g/lbf
3 - 179.0 Hz, 0.0060 g/lbf 4 - 140 Hz, 0.0023 g/lbf
40m 500m

400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf
20m
200m

10m
2 3 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER053 1 - 55 Hz, 0.0039 g/lbf PASS


1 - 189.0 Hz, 0.0788 g/lbf 2 - 70 Hz, 0.0177 g/lbf
2 - 192.0 Hz, 0.0560 g/lbf 3 - 110 Hz, 0.0036 g/lbf
3 - 195.0 Hz, 0.0486 g/lbf 4 - 140 Hz, 0.0043 g/lbf
1
80m 500m

400m
60m 2
3
300m
Amplitude g/lbf

Amplitude g/lbf

40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET053 1 - 55 Hz, 0.0028 g/lbf PASS


1 - 196.5 Hz, 0.0571 g/lbf 2 - 70 Hz, 0.0025 g/lbf
2 - 188.0 Hz, 0.0534 g/lbf 3 - 110 Hz, 0.0129 g/lbf
3 - 184.0 Hz, 0.0507 g/lbf 4 - 140 Hz, 0.0142 g/lbf
80m 500m

400m
60m 1
2
3
300m
Amplitude g/lbf

Amplitude g/lbf

40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1291 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA054 1 - 55 Hz, 0.0012 g/lbf PASS


1 - 199.0 Hz, 0.0171 g/lbf 2 - 70 Hz, 0.0043 g/lbf
2 - 72.0 Hz, 0.0073 g/lbf 3 - 110 Hz, 0.0022 g/lbf
3 - 175.0 Hz, 0.0045 g/lbf 4 - 140 Hz, 0.0021 g/lbf
20m 500m

400m
15m

300m
Amplitude g/lbf

Amplitude g/lbf
10m
2 200m

5m 3
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER054 1 - 55 Hz, 0.0037 g/lbf PASS


1 - 189.0 Hz, 0.0431 g/lbf 2 - 70 Hz, 0.0184 g/lbf
2 - 72.0 Hz, 0.0341 g/lbf 3 - 110 Hz, 0.0024 g/lbf
3 - 192.0 Hz, 0.0321 g/lbf 4 - 140 Hz, 0.0026 g/lbf
50m 500m
1
40m 400m
2
3
30m 300m
Amplitude g/lbf

Amplitude g/lbf

20m 200m

10m 100m

1 2
3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET054 1 - 55 Hz, 0.0025 g/lbf PASS


1 - 196.5 Hz, 0.0341 g/lbf 2 - 70 Hz, 0.0042 g/lbf
2 - 188.5 Hz, 0.0295 g/lbf 3 - 110 Hz, 0.0093 g/lbf
3 - 184.0 Hz, 0.0292 g/lbf 4 - 140 Hz, 0.0069 g/lbf
40m 500m
1
32 400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf

20m
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1292 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA055 1 - 55 Hz, 0.0010 g/lbf PASS


1 - 199.5 Hz, 0.0171 g/lbf 2 - 70 Hz, 0.0029 g/lbf
2 - 151.5 Hz, 0.0075 g/lbf 3 - 110 Hz, 0.0040 g/lbf
3 - 150.5 Hz, 0.0075 g/lbf 4 - 140 Hz, 0.0035 g/lbf
40m 500m

400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf
20m
200m

10m 32
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER055 1 - 55 Hz, 0.0038 g/lbf PASS


1 - 71.5 Hz, 0.0358 g/lbf 2 - 70 Hz, 0.0194 g/lbf
2 - 79.5 Hz, 0.0198 g/lbf 3 - 110 Hz, 0.0033 g/lbf
3 - 189.0 Hz, 0.0192 g/lbf 4 - 140 Hz, 0.0035 g/lbf
40m 500m
1

400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf

2 3
20m
200m

10m
100m

1 2
3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET055 1 - 55 Hz, 0.0020 g/lbf PASS


1 - 184.0 Hz, 0.0212 g/lbf 2 - 70 Hz, 0.0040 g/lbf
2 - 188.0 Hz, 0.0211 g/lbf 3 - 110 Hz, 0.0064 g/lbf
3 - 196.5 Hz, 0.0165 g/lbf 4 - 140 Hz, 0.0042 g/lbf
40m 500m

400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf

12
20m
3
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1293 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA056 1 - 55 Hz, 0.0010 g/lbf PASS


1 - 199.5 Hz, 0.0144 g/lbf 2 - 70 Hz, 0.0026 g/lbf
2 - 151.5 Hz, 0.0083 g/lbf 3 - 110 Hz, 0.0040 g/lbf
3 - 119.5 Hz, 0.0066 g/lbf 4 - 140 Hz, 0.0032 g/lbf
20m 500m

400m
15m

300m
Amplitude g/lbf

Amplitude g/lbf
10m
2
3 200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER056 1 - 55 Hz, 0.0038 g/lbf PASS


1 - 71.5 Hz, 0.0354 g/lbf 2 - 70 Hz, 0.0191 g/lbf
2 - 79.5 Hz, 0.0213 g/lbf 3 - 110 Hz, 0.0036 g/lbf
3 - 120.5 Hz, 0.0133 g/lbf 4 - 140 Hz, 0.0049 g/lbf
40m 500m
1

400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf

2
20m

3 200m

10m
100m

1 2
3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET056 1 - 55 Hz, 0.0026 g/lbf PASS


1 - 184.0 Hz, 0.0231 g/lbf 2 - 70 Hz, 0.0051 g/lbf
2 - 196.5 Hz, 0.0226 g/lbf 3 - 110 Hz, 0.0085 g/lbf
3 - 188.0 Hz, 0.0226 g/lbf 4 - 140 Hz, 0.0051 g/lbf
40m 500m

400m
30m

13 2 300m
Amplitude g/lbf

Amplitude g/lbf

20m
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1294 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA057 1 - 55 Hz, 0.0010 g/lbf PASS


1 - 151.5 Hz, 0.0106 g/lbf 2 - 70 Hz, 0.0023 g/lbf
2 - 119.5 Hz, 0.0103 g/lbf 3 - 110 Hz, 0.0057 g/lbf
3 - 199.5 Hz, 0.0100 g/lbf 4 - 140 Hz, 0.0031 g/lbf
20m 500m

400m
15m

300m
Amplitude g/lbf

Amplitude g/lbf
2 1
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER057 1 - 55 Hz, 0.0038 g/lbf PASS


1 - 71.5 Hz, 0.0346 g/lbf 2 - 70 Hz, 0.0187 g/lbf
2 - 79.5 Hz, 0.0223 g/lbf 3 - 110 Hz, 0.0036 g/lbf
3 - 120.5 Hz, 0.0143 g/lbf 4 - 140 Hz, 0.0060 g/lbf
40m 500m
1
400m
30m

2 300m
Amplitude g/lbf

Amplitude g/lbf

20m
3 200m

10m
100m

1 2
3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET057 1 - 55 Hz, 0.0005 g/lbf PASS


1 - 195.5 Hz, 0.0202 g/lbf 2 - 70 Hz, 0.0012 g/lbf
2 - 198.5 Hz, 0.0198 g/lbf 3 - 110 Hz, 0.0057 g/lbf
3 - 116.0 Hz, 0.0118 g/lbf 4 - 140 Hz, 0.0056 g/lbf
40m 500m

400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf

1
20m
200m
3
10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1295 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA058 1 - 55 Hz, 0.0013 g/lbf PASS


1 - 119.5 Hz, 0.0116 g/lbf 2 - 70 Hz, 0.0035 g/lbf
2 - 151.5 Hz, 0.0110 g/lbf 3 - 110 Hz, 0.0058 g/lbf
3 - 116.5 Hz, 0.0091 g/lbf 4 - 140 Hz, 0.0025 g/lbf
20m 500m

400m
15m
1 300m
Amplitude g/lbf

Amplitude g/lbf
10m 3
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER058 1 - 55 Hz, 0.0039 g/lbf PASS


1 - 71.5 Hz, 0.0334 g/lbf 2 - 70 Hz, 0.0185 g/lbf
2 - 79.5 Hz, 0.0231 g/lbf 3 - 110 Hz, 0.0041 g/lbf
3 - 120.5 Hz, 0.0193 g/lbf 4 - 140 Hz, 0.0069 g/lbf
40m 500m
1
400m
30m

2 300m
Amplitude g/lbf

Amplitude g/lbf

20m 3

200m

10m
100m

1 2
3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET058 1 - 55 Hz, 0.0019 g/lbf PASS


1 - 196.5 Hz, 0.0272 g/lbf 2 - 70 Hz, 0.0034 g/lbf
2 - 199.5 Hz, 0.0271 g/lbf 3 - 110 Hz, 0.0087 g/lbf
3 - 188.0 Hz, 0.0199 g/lbf 4 - 140 Hz, 0.0067 g/lbf
40m 500m

400m
30m 1

300m
Amplitude g/lbf

Amplitude g/lbf

3
20m
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1296 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA059 1 - 55 Hz, 0.0013 g/lbf PASS


1 - 119.5 Hz, 0.0162 g/lbf 2 - 70 Hz, 0.0030 g/lbf
2 - 151.5 Hz, 0.0136 g/lbf 3 - 110 Hz, 0.0081 g/lbf
3 - 116.5 Hz, 0.0130 g/lbf 4 - 140 Hz, 0.0031 g/lbf
20m 500m

1
400m
15m 2
3
300m
Amplitude g/lbf

Amplitude g/lbf
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER059 1 - 55 Hz, 0.0034 g/lbf PASS


1 - 198.0 Hz, 0.0283 g/lbf 2 - 70 Hz, 0.0154 g/lbf
2 - 71.5 Hz, 0.0275 g/lbf 3 - 110 Hz, 0.0047 g/lbf
3 - 188.5 Hz, 0.0271 g/lbf 4 - 140 Hz, 0.0064 g/lbf
40m 500m

400m
30m 2 3

300m
Amplitude g/lbf

Amplitude g/lbf

20m
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET059 1 - 55 Hz, 0.0048 g/lbf PASS


1 - 188.5 Hz, 0.0687 g/lbf 2 - 70 Hz, 0.0146 g/lbf
2 - 195.5 Hz, 0.0409 g/lbf 3 - 110 Hz, 0.0074 g/lbf
3 - 198.0 Hz, 0.0380 g/lbf 4 - 140 Hz, 0.0035 g/lbf
80m 500m
1
400m
60m

300m
Amplitude g/lbf

Amplitude g/lbf

2
40m 3
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1297 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA060 1 - 55 Hz, 0.0015 g/lbf PASS


1 - 119.5 Hz, 0.0225 g/lbf 2 - 70 Hz, 0.0027 g/lbf
2 - 116.5 Hz, 0.0186 g/lbf 3 - 110 Hz, 0.0120 g/lbf
3 - 151.0 Hz, 0.0172 g/lbf 4 - 140 Hz, 0.0045 g/lbf
40m 500m

400m
30m

1 300m
Amplitude g/lbf

Amplitude g/lbf
20m 2
3
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER060 1 - 55 Hz, 0.0035 g/lbf PASS


1 - 188.5 Hz, 0.0576 g/lbf 2 - 70 Hz, 0.0140 g/lbf
2 - 198.0 Hz, 0.0478 g/lbf 3 - 110 Hz, 0.0083 g/lbf
3 - 192.0 Hz, 0.0409 g/lbf 4 - 140 Hz, 0.0055 g/lbf
80m 500m

1 400m
60m
2
300m
Amplitude g/lbf

Amplitude g/lbf

3
40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET060 1 - 55 Hz, 0.0037 g/lbf PASS


1 - 196.0 Hz, 0.0358 g/lbf 2 - 70 Hz, 0.0086 g/lbf
2 - 198.5 Hz, 0.0357 g/lbf 3 - 110 Hz, 0.0143 g/lbf
3 - 119.5 Hz, 0.0253 g/lbf 4 - 140 Hz, 0.0047 g/lbf
40m 500m
1

400m
30m
3
300m
Amplitude g/lbf

Amplitude g/lbf

20m
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1298 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA064 1 - 55 Hz, 0.0016 g/lbf PASS


1 - 187.5 Hz, 0.0202 g/lbf 2 - 70 Hz, 0.0029 g/lbf
2 - 191.5 Hz, 0.0156 g/lbf 3 - 110 Hz, 0.0073 g/lbf
3 - 199.0 Hz, 0.0154 g/lbf 4 - 140 Hz, 0.0041 g/lbf
40m 500m

400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf
1
20m
2
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER064 1 - 55 Hz, 0.0042 g/lbf PASS


1 - 184.5 Hz, 0.1350 g/lbf 2 - 70 Hz, 0.0181 g/lbf
2 - 189.5 Hz, 0.0895 g/lbf 3 - 110 Hz, 0.0061 g/lbf
3 - 177.5 Hz, 0.0624 g/lbf 4 - 140 Hz, 0.0054 g/lbf
200m 500m

400m
1

300m
Amplitude g/lbf

Amplitude g/lbf

100m 2
200m
3

100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET064 1 - 55 Hz, 0.0014 g/lbf PASS


1 - 184.0 Hz, 0.0388 g/lbf 2 - 70 Hz, 0.0015 g/lbf
2 - 189.5 Hz, 0.0306 g/lbf 3 - 110 Hz, 0.0062 g/lbf
3 - 125.0 Hz, 0.0217 g/lbf 4 - 140 Hz, 0.0025 g/lbf
40m 1 500m

2 400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf

3
20m
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1299 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA065 1 - 55 Hz, 0.0013 g/lbf PASS


1 - 188.0 Hz, 0.0148 g/lbf 2 - 70 Hz, 0.0039 g/lbf
2 - 191.5 Hz, 0.0108 g/lbf 3 - 110 Hz, 0.0043 g/lbf
3 - 199.0 Hz, 0.0097 g/lbf 4 - 140 Hz, 0.0020 g/lbf
20m 500m

1 400m
15m

300m
Amplitude g/lbf

Amplitude g/lbf
2
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER065 1 - 55 Hz, 0.0039 g/lbf PASS


1 - 184.5 Hz, 0.0927 g/lbf 2 - 70 Hz, 0.0197 g/lbf
2 - 189.5 Hz, 0.0653 g/lbf 3 - 110 Hz, 0.0028 g/lbf
3 - 177.5 Hz, 0.0403 g/lbf 4 - 140 Hz, 0.0023 g/lbf
100m 1 500m

400m
2
300m
Amplitude g/lbf

Amplitude g/lbf

50m
3
200m

100m

1 2
3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET065 1 - 55 Hz, 0.0014 g/lbf PASS


1 - 186.0 Hz, 0.0181 g/lbf 2 - 70 Hz, 0.0007 g/lbf
2 - 195.5 Hz, 0.0174 g/lbf 3 - 110 Hz, 0.0053 g/lbf
3 - 189.5 Hz, 0.0144 g/lbf 4 - 140 Hz, 0.0028 g/lbf
20m 1
500m
2
400m
15m 3

300m
Amplitude g/lbf

Amplitude g/lbf

10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1300 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA066 1 - 55 Hz, 0.0013 g/lbf PASS


1 - 188.0 Hz, 0.0131 g/lbf 2 - 70 Hz, 0.0043 g/lbf
2 - 192.0 Hz, 0.0097 g/lbf 3 - 110 Hz, 0.0034 g/lbf
3 - 193.0 Hz, 0.0089 g/lbf 4 - 140 Hz, 0.0017 g/lbf
20m 500m

400m
15m
1
300m
Amplitude g/lbf

Amplitude g/lbf
10m 2
3
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER066 1 - 55 Hz, 0.0036 g/lbf PASS


1 - 184.5 Hz, 0.0460 g/lbf 2 - 70 Hz, 0.0194 g/lbf
2 - 189.5 Hz, 0.0352 g/lbf 3 - 110 Hz, 0.0024 g/lbf
3 - 68.5 Hz, 0.0246 g/lbf 4 - 140 Hz, 0.0031 g/lbf
50m 1 500m

40m 400m
2

30m 300m
Amplitude g/lbf

Amplitude g/lbf

20m 200m

10m 100m

1 2
3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET066 1 - 55 Hz, 0.0005 g/lbf PASS


1 - 187.0 Hz, 0.0116 g/lbf 2 - 70 Hz, 0.0015 g/lbf
2 - 196.5 Hz, 0.0114 g/lbf 3 - 110 Hz, 0.0025 g/lbf
3 - 125.0 Hz, 0.0114 g/lbf 4 - 140 Hz, 0.0020 g/lbf
20m 500m

400m
15m

3 1 2 300m
Amplitude g/lbf

Amplitude g/lbf

10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1301 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA067 1 - 55 Hz, 0.0009 g/lbf PASS


1 - 188.0 Hz, 0.0114 g/lbf 2 - 70 Hz, 0.0016 g/lbf
2 - 183.5 Hz, 0.0105 g/lbf 3 - 110 Hz, 0.0045 g/lbf
3 - 191.5 Hz, 0.0093 g/lbf 4 - 140 Hz, 0.0023 g/lbf
20m 500m

400m
15m

1 300m
Amplitude g/lbf

Amplitude g/lbf
2
10m 3
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER067 1 - 55 Hz, 0.0036 g/lbf PASS


1 - 68.5 Hz, 0.0258 g/lbf 2 - 70 Hz, 0.0204 g/lbf
2 - 185.0 Hz, 0.0219 g/lbf 3 - 110 Hz, 0.0035 g/lbf
3 - 189.5 Hz, 0.0186 g/lbf 4 - 140 Hz, 0.0047 g/lbf
40m 500m

400m
30m
1
300m
Amplitude g/lbf

2
Amplitude g/lbf

20m 3
200m

10m
100m

1 2
3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET067 1 - 55 Hz, 0.0006 g/lbf PASS


1 - 125.0 Hz, 0.0190 g/lbf 2 - 70 Hz, 0.0013 g/lbf
2 - 123.0 Hz, 0.0161 g/lbf 3 - 110 Hz, 0.0042 g/lbf
3 - 186.5 Hz, 0.0115 g/lbf 4 - 140 Hz, 0.0030 g/lbf
20m 1 500m

2
400m
15m

3 300m
Amplitude g/lbf

Amplitude g/lbf

10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1302 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA068 1 - 55 Hz, 0.0009 g/lbf PASS


1 - 183.5 Hz, 0.0095 g/lbf 2 - 70 Hz, 0.0017 g/lbf
2 - 128.0 Hz, 0.0083 g/lbf 3 - 110 Hz, 0.0041 g/lbf
3 - 188.0 Hz, 0.0082 g/lbf 4 - 140 Hz, 0.0019 g/lbf
20m 500m

400m
15m

300m
Amplitude g/lbf

Amplitude g/lbf
10m 1
2 3
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER068 1 - 55 Hz, 0.0033 g/lbf PASS


1 - 68.5 Hz, 0.0239 g/lbf 2 - 70 Hz, 0.0190 g/lbf
2 - 92.0 Hz, 0.0171 g/lbf 3 - 110 Hz, 0.0035 g/lbf
3 - 64.0 Hz, 0.0138 g/lbf 4 - 140 Hz, 0.0051 g/lbf
40m 500m

400m
30m
1
300m
Amplitude g/lbf

Amplitude g/lbf

20m 2
3 200m

10m
100m

1 2
3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET068 1 - 55 Hz, 0.0004 g/lbf PASS


1 - 125.0 Hz, 0.0221 g/lbf 2 - 70 Hz, 0.0021 g/lbf
2 - 123.0 Hz, 0.0178 g/lbf 3 - 110 Hz, 0.0048 g/lbf
3 - 131.0 Hz, 0.0124 g/lbf 4 - 140 Hz, 0.0034 g/lbf
40m 500m

400m
30m

1 300m
Amplitude g/lbf

Amplitude g/lbf

20m 2
200m
3
10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1303 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA069 1 - 55 Hz, 0.0010 g/lbf PASS


1 - 122.5 Hz, 0.0114 g/lbf 2 - 70 Hz, 0.0016 g/lbf
2 - 125.0 Hz, 0.0114 g/lbf 3 - 110 Hz, 0.0050 g/lbf
3 - 128.0 Hz, 0.0111 g/lbf 4 - 140 Hz, 0.0023 g/lbf
20m 500m

400m
15m

123 300m
Amplitude g/lbf

Amplitude g/lbf
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER069 1 - 55 Hz, 0.0033 g/lbf PASS


1 - 68.5 Hz, 0.0234 g/lbf 2 - 70 Hz, 0.0184 g/lbf
2 - 92.0 Hz, 0.0169 g/lbf 3 - 110 Hz, 0.0039 g/lbf
3 - 121.0 Hz, 0.0157 g/lbf 4 - 140 Hz, 0.0060 g/lbf
40m 500m

400m
30m
1
300m
Amplitude g/lbf

Amplitude g/lbf

20m
2
3
200m

10m
100m

1 2
3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET069 1 - 55 Hz, 0.0009 g/lbf PASS


1 - 125.0 Hz, 0.0233 g/lbf 2 - 70 Hz, 0.0013 g/lbf
2 - 123.0 Hz, 0.0199 g/lbf 3 - 110 Hz, 0.0056 g/lbf
3 - 126.5 Hz, 0.0178 g/lbf 4 - 140 Hz, 0.0034 g/lbf
40m 500m

400m
30m
1 300m
Amplitude g/lbf

Amplitude g/lbf

2
20m 3
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1304 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA070 1 - 55 Hz, 0.0011 g/lbf PASS


1 - 128.0 Hz, 0.0131 g/lbf 2 - 70 Hz, 0.0024 g/lbf
2 - 125.0 Hz, 0.0127 g/lbf 3 - 110 Hz, 0.0042 g/lbf
3 - 122.5 Hz, 0.0123 g/lbf 4 - 140 Hz, 0.0020 g/lbf
20m 500m

400m
15m
1
32
300m
Amplitude g/lbf

Amplitude g/lbf
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER070 1 - 55 Hz, 0.0031 g/lbf PASS


1 - 68.5 Hz, 0.0210 g/lbf 2 - 70 Hz, 0.0164 g/lbf
2 - 185.5 Hz, 0.0192 g/lbf 3 - 110 Hz, 0.0051 g/lbf
3 - 121.0 Hz, 0.0189 g/lbf 4 - 140 Hz, 0.0057 g/lbf
40m 500m

400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf

1
20m 3 2

200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET070 1 - 55 Hz, 0.0010 g/lbf PASS


1 - 125.0 Hz, 0.0220 g/lbf 2 - 70 Hz, 0.0005 g/lbf
2 - 185.5 Hz, 0.0189 g/lbf 3 - 110 Hz, 0.0050 g/lbf
3 - 123.0 Hz, 0.0184 g/lbf 4 - 140 Hz, 0.0030 g/lbf
40m 500m

400m
30m

1 300m
Amplitude g/lbf

Amplitude g/lbf

20m 3 2
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1305 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA071 1 - 55 Hz, 0.0011 g/lbf PASS


1 - 125.0 Hz, 0.0163 g/lbf 2 - 70 Hz, 0.0025 g/lbf
2 - 128.0 Hz, 0.0154 g/lbf 3 - 110 Hz, 0.0046 g/lbf
3 - 123.0 Hz, 0.0151 g/lbf 4 - 140 Hz, 0.0023 g/lbf
20m 500m

1
32 400m
15m

300m
Amplitude g/lbf

Amplitude g/lbf
10m
200m

5m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER071 1 - 55 Hz, 0.0031 g/lbf PASS


1 - 185.0 Hz, 0.0442 g/lbf 2 - 70 Hz, 0.0150 g/lbf
2 - 189.5 Hz, 0.0397 g/lbf 3 - 110 Hz, 0.0075 g/lbf
3 - 120.5 Hz, 0.0234 g/lbf 4 - 140 Hz, 0.0059 g/lbf
50m 500m
1
2
40m 400m

30m 300m
Amplitude g/lbf

Amplitude g/lbf

3
20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET071 1 - 55 Hz, 0.0016 g/lbf PASS


1 - 125.0 Hz, 0.0269 g/lbf 2 - 70 Hz, 0.0017 g/lbf
2 - 186.0 Hz, 0.0246 g/lbf 3 - 110 Hz, 0.0070 g/lbf
3 - 123.0 Hz, 0.0232 g/lbf 4 - 140 Hz, 0.0033 g/lbf
40m 500m

400m
30m 1
2
3 300m
Amplitude g/lbf

Amplitude g/lbf

20m
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1306 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END SERIES LOOP RESPONSES

CEA072 1 - 55 Hz, 0.0011 g/lbf PASS


1 - 125.0 Hz, 0.0267 g/lbf 2 - 70 Hz, 0.0018 g/lbf
2 - 122.5 Hz, 0.0253 g/lbf 3 - 110 Hz, 0.0078 g/lbf
3 - 126.5 Hz, 0.0211 g/lbf 4 - 140 Hz, 0.0046 g/lbf
40m 500m

400m
30m
1
2
300m
Amplitude g/lbf

Amplitude g/lbf
3
20m
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CER072 1 - 55 Hz, 0.0030 g/lbf PASS


1 - 185.0 Hz, 0.0439 g/lbf 2 - 70 Hz, 0.0148 g/lbf
2 - 189.5 Hz, 0.0394 g/lbf 3 - 110 Hz, 0.0073 g/lbf
3 - 120.5 Hz, 0.0230 g/lbf 4 - 140 Hz, 0.0058 g/lbf
50m 500m
1
2
40m 400m

30m 300m
Amplitude g/lbf

Amplitude g/lbf

3
20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CET072 1 - 55 Hz, 0.0050 g/lbf PASS


1 - 183.5 Hz, 0.0692 g/lbf 2 - 70 Hz, 0.0134 g/lbf
2 - 188.5 Hz, 0.0507 g/lbf 3 - 110 Hz, 0.0111 g/lbf
3 - 177.5 Hz, 0.0436 g/lbf 4 - 140 Hz, 0.0033 g/lbf
80m 500m
1
400m
60m
2
300m
Amplitude g/lbf

3
Amplitude g/lbf

40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1307 of 1653


Bump Test_As Left

GE Power Inspection & Life Extension Services


Endwinding Vibration Test Report

Enclosure 3
Collector End Phase Connection Frequency Response
(Amplitude versus Frequency)

GE Proprietary Information. This document contains proprietary information of the General Electric Company and
may not be used or disclosed to others, except with the written permission of General Electric Company. 9

Page 1308 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCBA001 1 - 55 Hz, 0.0071 g/lbf PASS


1 - 143.5 Hz, 0.1233 g/lbf 2 - 70 Hz, 0.0039 g/lbf
2 - 139.5 Hz, 0.1095 g/lbf 3 - 110 Hz, 0.0223 g/lbf
3 - 120.0 Hz, 0.0777 g/lbf 4 - 140 Hz, 0.1072 g/lbf
200m 500m

400m

1
300m
Amplitude g/lbf

Amplitude g/lbf
100m
3
200m

100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBR001 1 - 55 Hz, 0.0366 g/lbf PASS


1 - 53.0 Hz, 0.1024 g/lbf 2 - 70 Hz, 0.0057 g/lbf
2 - 76.5 Hz, 0.0824 g/lbf 3 - 110 Hz, 0.0142 g/lbf
3 - 116.0 Hz, 0.0577 g/lbf 4 - 140 Hz, 0.0152 g/lbf
200m 500m

400m

300m
Amplitude g/lbf

Amplitude g/lbf

1
100m
2
200m
3

100m
1
2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBT001 1 - 55 Hz, 0.0482 g/lbf PASS


1 - 53.0 Hz, 0.2196 g/lbf 2 - 70 Hz, 0.0427 g/lbf
2 - 65.0 Hz, 0.1247 g/lbf 3 - 110 Hz, 0.0088 g/lbf
3 - 139.5 Hz, 0.0853 g/lbf 4 - 140 Hz, 0.0816 g/lbf
400m 500m

400m
300m

300m
Amplitude g/lbf

1
Amplitude g/lbf

200m
200m
2
100m 3
100m
1 2
3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1309 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCTA001 1 - 55 Hz, 0.0093 g/lbf PASS


1 - 197.5 Hz, 0.0996 g/lbf 2 - 70 Hz, 0.0039 g/lbf
2 - 168.5 Hz, 0.0551 g/lbf 3 - 110 Hz, 0.0088 g/lbf
3 - 53.5 Hz, 0.0452 g/lbf 4 - 140 Hz, 0.0091 g/lbf
100m 500m

400m

2 300m
Amplitude g/lbf

Amplitude g/lbf
50m 3
200m

100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTR001 1 - 55 Hz, 0.0374 g/lbf PASS


1 - 53.0 Hz, 0.1112 g/lbf 2 - 70 Hz, 0.0062 g/lbf
2 - 76.5 Hz, 0.0734 g/lbf 3 - 110 Hz, 0.0186 g/lbf
3 - 116.0 Hz, 0.0614 g/lbf 4 - 140 Hz, 0.0213 g/lbf
200m 500m

400m

1 300m
Amplitude g/lbf

Amplitude g/lbf

100m
2 200m
3

100m
1
2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTT001 1 - 55 Hz, 0.0291 g/lbf PASS


1 - 53.5 Hz, 0.1192 g/lbf 2 - 70 Hz, 0.0138 g/lbf
2 - 120.0 Hz, 0.0912 g/lbf 3 - 110 Hz, 0.0117 g/lbf
3 - 170.0 Hz, 0.0801 g/lbf 4 - 140 Hz, 0.0742 g/lbf
200m 500m

400m

1
300m
Amplitude g/lbf

Amplitude g/lbf

100m 2
3
200m

100m
1
2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1310 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCBA002 1 - 55 Hz, 0.0040 g/lbf PASS


1 - 168.5 Hz, 0.0743 g/lbf 2 - 70 Hz, 0.0072 g/lbf
2 - 175.0 Hz, 0.0681 g/lbf 3 - 110 Hz, 0.0130 g/lbf
3 - 188.5 Hz, 0.0623 g/lbf 4 - 140 Hz, 0.0196 g/lbf
80m 1 500m
2
3 400m
60m

300m
Amplitude g/lbf

Amplitude g/lbf
40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBR002 1 - 55 Hz, 0.0122 g/lbf PASS


1 - 76.5 Hz, 0.1267 g/lbf 2 - 70 Hz, 0.0237 g/lbf
2 - 64.5 Hz, 0.1139 g/lbf 3 - 110 Hz, 0.0400 g/lbf
3 - 94.5 Hz, 0.0962 g/lbf 4 - 140 Hz, 0.0325 g/lbf
200m 500m

400m
1
2 300m
Amplitude g/lbf

Amplitude g/lbf

3
100m
200m

100m
2 3
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBT002 1 - 55 Hz, 0.1249 g/lbf PASS


1 - 159.5 Hz, 0.3245 g/lbf 2 - 70 Hz, 0.1141 g/lbf
2 - 53.5 Hz, 0.2828 g/lbf 3 - 110 Hz, 0.0242 g/lbf
3 - 52.5 Hz, 0.2817 g/lbf 4 - 140 Hz, 0.0166 g/lbf
400m 500m
1
400m
300m 32

300m
Amplitude g/lbf

Amplitude g/lbf

200m
200m
1 2
100m
100m
3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1311 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCTA002 1 - 55 Hz, 0.0033 g/lbf PASS


1 - 126.0 Hz, 0.1001 g/lbf 2 - 70 Hz, 0.0061 g/lbf
2 - 128.5 Hz, 0.0722 g/lbf 3 - 110 Hz, 0.0317 g/lbf
3 - 130.5 Hz, 0.0649 g/lbf 4 - 140 Hz, 0.0319 g/lbf
200m 500m

400m

300m
Amplitude g/lbf

Amplitude g/lbf
1
100m
2 200m
3

100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTR002 1 - 55 Hz, 0.0214 g/lbf PASS


1 - 183.5 Hz, 0.1962 g/lbf 2 - 70 Hz, 0.0054 g/lbf
2 - 197.0 Hz, 0.1001 g/lbf 3 - 110 Hz, 0.0130 g/lbf
3 - 129.5 Hz, 0.0954 g/lbf 4 - 140 Hz, 0.0306 g/lbf
1
200m 500m

400m

300m
Amplitude g/lbf

Amplitude g/lbf

3 2
100m
200m

100m
1 3
2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTT002 1 - 55 Hz, 0.0932 g/lbf PASS


1 - 126.0 Hz, 0.3901 g/lbf 2 - 70 Hz, 0.0472 g/lbf
2 - 159.5 Hz, 0.3683 g/lbf 3 - 110 Hz, 0.1026 g/lbf
3 - 129.5 Hz, 0.2640 g/lbf 1 4 - 140 Hz, 0.0870 g/lbf
400m 2 500m

400m
300m
3
300m
Amplitude g/lbf

Amplitude g/lbf

200m
200m

100m 1 3
100m
2

0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1312 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCBA003 1 - 55 Hz, 0.0066 g/lbf PASS


1 - 144.5 Hz, 0.1596 g/lbf 2 - 70 Hz, 0.0279 g/lbf
2 - 188.0 Hz, 0.0948 g/lbf 3 - 110 Hz, 0.0290 g/lbf
3 - 125.0 Hz, 0.0793 g/lbf 4 - 140 Hz, 0.0629 g/lbf
200m 500m

1
400m

300m
Amplitude g/lbf

Amplitude g/lbf
100m 2
3
200m

100m
2 3
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBR003 1 - 55 Hz, 0.0053 g/lbf PASS


1 - 144.0 Hz, 0.3710 g/lbf 2 - 70 Hz, 0.0241 g/lbf
2 - 184.5 Hz, 0.1756 g/lbf 3 - 110 Hz, 0.0391 g/lbf
3 - 125.0 Hz, 0.1663 g/lbf 4 - 140 Hz, 0.1391 g/lbf
400m 1 500m

400m
300m

300m
Amplitude g/lbf

Amplitude g/lbf

200m 3 2
200m

100m
100m
2 3
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBT003 1 - 55 Hz, 0.0160 g/lbf PASS


1 - 76.0 Hz, 0.3710 g/lbf 2 - 70 Hz, 0.1021 g/lbf
2 - 115.5 Hz, 0.1759 g/lbf 3 - 110 Hz, 0.0474 g/lbf
3 - 120.5 Hz, 0.1549 g/lbf 4 - 140 Hz, 0.0538 g/lbf
400m 1 500m

400m
300m

300m
Amplitude g/lbf

Amplitude g/lbf

200m 2
3
200m

100m 2
100m
3
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1313 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCTA003 1 - 55 Hz, 0.0060 g/lbf PASS


1 - 144.0 Hz, 0.7415 g/lbf 2 - 70 Hz, 0.0205 g/lbf
2 - 185.0 Hz, 0.2330 g/lbf 3 - 110 Hz, 0.0377 g/lbf
3 - 169.5 Hz, 0.2063 g/lbf 4 - 140 Hz, 0.3343 g/lbf
800m 1 500m

400m
600m

300m
Amplitude g/lbf

Amplitude g/lbf
400m
200m
2
3
200m
100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTR003 1 - 55 Hz, 0.0274 g/lbf PASS


1 - 76.0 Hz, 0.4870 g/lbf 2 - 70 Hz, 0.1023 g/lbf
2 - 126.0 Hz, 0.2856 g/lbf 3 - 110 Hz, 0.0917 g/lbf
3 - 115.0 Hz, 0.2725 g/lbf 4 - 140 Hz, 0.0764 g/lbf
1
500m 500m

400m 400m

300m 3 2 300m
Amplitude g/lbf

Amplitude g/lbf

200m 200m

2 3
100m 100m
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTT003 1 - 55 Hz, 0.0068 g/lbf PASS


1 - 184.5 Hz, 0.3317 g/lbf 2 - 70 Hz, 0.0641 g/lbf
2 - 76.0 Hz, 0.2432 g/lbf 3 - 110 Hz, 0.0082 g/lbf
3 - 164.5 Hz, 0.2226 g/lbf 4 - 140 Hz, 0.0357 g/lbf
400m 500m
1
400m
300m
2
3 300m
Amplitude g/lbf

Amplitude g/lbf

200m
200m

100m
100m 2
1 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1314 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCBA013 1 - 55 Hz, 0.0089 g/lbf PASS


1 - 140.5 Hz, 0.1858 g/lbf 2 - 70 Hz, 0.0175 g/lbf
2 - 112.5 Hz, 0.1718 g/lbf 3 - 110 Hz, 0.1124 g/lbf
3 - 144.0 Hz, 0.1269 g/lbf 4 - 140 Hz, 0.1812 g/lbf
200m 1 500m
2
400m
3
300m
Amplitude g/lbf

Amplitude g/lbf
100m
200m

3
100m

1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBR013 1 - 55 Hz, 0.0076 g/lbf PASS


1 - 112.0 Hz, 0.4612 g/lbf 2 - 70 Hz, 0.0213 g/lbf
2 - 126.0 Hz, 0.2443 g/lbf 3 - 110 Hz, 0.3658 g/lbf
3 - 138.5 Hz, 0.0992 g/lbf 4 - 140 Hz, 0.0867 g/lbf
500m 1 500m

400m 400m 3

300m 300m
Amplitude g/lbf

Amplitude g/lbf

200m 200m

3
100m 100m

1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBT013 1 - 55 Hz, 0.0253 g/lbf PASS


1 - 113.0 Hz, 0.2420 g/lbf 2 - 70 Hz, 0.0250 g/lbf
2 - 86.5 Hz, 0.1919 g/lbf 3 - 110 Hz, 0.1149 g/lbf
3 - 141.0 Hz, 0.1802 g/lbf 4 - 140 Hz, 0.1604 g/lbf
400m 500m

400m
300m
1
300m
Amplitude g/lbf

Amplitude g/lbf

200m 2
3
200m

100m 3
100m
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1315 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCTA013 1 - 55 Hz, 0.0065 g/lbf PASS


1 - 159.0 Hz, 0.2511 g/lbf 2 - 70 Hz, 0.0147 g/lbf
2 - 180.5 Hz, 0.1567 g/lbf 3 - 110 Hz, 0.0422 g/lbf
3 - 170.0 Hz, 0.1392 g/lbf 4 - 140 Hz, 0.0744 g/lbf
400m 500m

400m
300m
1
300m
Amplitude g/lbf

Amplitude g/lbf
200m
2
3 200m

100m
100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTR013 1 - 55 Hz, 0.0171 g/lbf PASS


1 - 100.0 Hz, 0.2007 g/lbf 2 - 70 Hz, 0.0665 g/lbf
2 - 113.0 Hz, 0.1899 g/lbf 3 - 110 Hz, 0.1089 g/lbf
3 - 81.0 Hz, 0.1315 g/lbf 4 - 140 Hz, 0.0801 g/lbf
400m 500m

400m
300m

300m
Amplitude g/lbf

Amplitude g/lbf

1 2
200m
3 200m

100m 3
100m 2
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTT013 1 - 55 Hz, 0.0235 g/lbf PASS


1 - 86.5 Hz, 0.1507 g/lbf 2 - 70 Hz, 0.0246 g/lbf
2 - 113.0 Hz, 0.1402 g/lbf 3 - 110 Hz, 0.0806 g/lbf
3 - 179.5 Hz, 0.0922 g/lbf 4 - 140 Hz, 0.0349 g/lbf
200m 500m

1 400m
2

300m
Amplitude g/lbf

Amplitude g/lbf

100m 3
200m

100m 3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1316 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCBA014 1 - 55 Hz, 0.0078 g/lbf PASS


1 - 139.0 Hz, 0.0955 g/lbf 2 - 70 Hz, 0.0125 g/lbf
2 - 158.5 Hz, 0.0806 g/lbf 3 - 110 Hz, 0.0248 g/lbf
3 - 145.5 Hz, 0.0480 g/lbf 4 - 140 Hz, 0.0892 g/lbf
100m 1 500m

2
400m

300m
Amplitude g/lbf

Amplitude g/lbf
3
50m
200m

100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBR014 1 - 55 Hz, 0.0072 g/lbf PASS


1 - 100.5 Hz, 0.1096 g/lbf 2 - 70 Hz, 0.0107 g/lbf
2 - 194.0 Hz, 0.0970 g/lbf 3 - 110 Hz, 0.0219 g/lbf
3 - 158.0 Hz, 0.0932 g/lbf 4 - 140 Hz, 0.0276 g/lbf
200m 500m

400m

300m
Amplitude g/lbf

1
Amplitude g/lbf

3 2
100m
200m

100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBT014 1 - 55 Hz, 0.0634 g/lbf PASS


1 - 138.5 Hz, 0.1448 g/lbf 2 - 70 Hz, 0.0306 g/lbf
2 - 60.5 Hz, 0.1386 g/lbf 3 - 110 Hz, 0.0090 g/lbf
3 - 136.0 Hz, 0.1354 g/lbf 4 - 140 Hz, 0.1265 g/lbf
200m 500m

1 400m
2 3

300m
Amplitude g/lbf

Amplitude g/lbf

100m
200m

100m 1
2
3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1317 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCTA014 1 - 55 Hz, 0.0052 g/lbf PASS


1 - 158.5 Hz, 0.0659 g/lbf 2 - 70 Hz, 0.0067 g/lbf
2 - 194.5 Hz, 0.0646 g/lbf 3 - 110 Hz, 0.0211 g/lbf
3 - 169.5 Hz, 0.0475 g/lbf 4 - 140 Hz, 0.0185 g/lbf
80m 500m
1 2
400m
60m
3
300m
Amplitude g/lbf

Amplitude g/lbf
40m
200m

20m
100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTR014 1 - 55 Hz, 0.0053 g/lbf PASS


1 - 100.5 Hz, 0.1202 g/lbf 2 - 70 Hz, 0.0106 g/lbf
2 - 158.0 Hz, 0.0962 g/lbf 3 - 110 Hz, 0.0228 g/lbf
3 - 126.0 Hz, 0.0864 g/lbf 4 - 140 Hz, 0.0212 g/lbf
200m 500m

400m

1
300m
Amplitude g/lbf

Amplitude g/lbf

2
100m 3
200m

100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTT014 1 - 55 Hz, 0.0726 g/lbf PASS


1 - 60.5 Hz, 0.1776 g/lbf 2 - 70 Hz, 0.0433 g/lbf
2 - 87.0 Hz, 0.1629 g/lbf 3 - 110 Hz, 0.0453 g/lbf
3 - 73.0 Hz, 0.0979 g/lbf 4 - 140 Hz, 0.0242 g/lbf
200m 500m
1
2
400m

300m
Amplitude g/lbf

Amplitude g/lbf

3
100m
200m

100m 1
2 3

0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1318 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCBA015 1 - 55 Hz, 0.0116 g/lbf PASS


1 - 174.5 Hz, 0.1453 g/lbf 2 - 70 Hz, 0.0085 g/lbf
2 - 176.5 Hz, 0.1382 g/lbf 3 - 110 Hz, 0.0179 g/lbf
3 - 195.0 Hz, 0.1070 g/lbf 4 - 140 Hz, 0.0221 g/lbf
200m 500m

1 400m
2

300m
Amplitude g/lbf

Amplitude g/lbf
3
100m
200m

100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBR015 1 - 55 Hz, 0.0319 g/lbf PASS


1 - 100.0 Hz, 0.4732 g/lbf 2 - 70 Hz, 0.0040 g/lbf
2 - 113.0 Hz, 0.2082 g/lbf 3 - 110 Hz, 0.1164 g/lbf
3 - 157.5 Hz, 0.1520 g/lbf 4 - 140 Hz, 0.0583 g/lbf
500m 1 500m

400m 400m

300m 300m
Amplitude g/lbf

Amplitude g/lbf

2
200m 200m
3
3
100m 100m
1
2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBT015 1 - 55 Hz, 0.0622 g/lbf PASS


1 - 59.5 Hz, 0.2069 g/lbf 2 - 70 Hz, 0.0188 g/lbf
2 - 100.5 Hz, 0.1574 g/lbf 3 - 110 Hz, 0.0430 g/lbf
3 - 81.0 Hz, 0.0704 g/lbf 4 - 140 Hz, 0.0157 g/lbf
400m 500m

400m
300m

300m
Amplitude g/lbf

Amplitude g/lbf

1
200m
2
200m

100m 3 100m 1
3
2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1319 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCTA015 1 - 55 Hz, 0.0111 g/lbf PASS


1 - 157.0 Hz, 0.4908 g/lbf 2 - 70 Hz, 0.0103 g/lbf
2 - 165.5 Hz, 0.3169 g/lbf 3 - 110 Hz, 0.0464 g/lbf
3 - 174.5 Hz, 0.2593 g/lbf 1 4 - 140 Hz, 0.1144 g/lbf
500m 500m

400m 400m
2
300m 300m
Amplitude g/lbf

Amplitude g/lbf
3

200m 200m

100m 100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTR015 1 - 55 Hz, 0.0636 g/lbf PASS


1 - 59.5 Hz, 0.2293 g/lbf 2 - 70 Hz, 0.0198 g/lbf
2 - 80.5 Hz, 0.1919 g/lbf 3 - 110 Hz, 0.0423 g/lbf
3 - 126.0 Hz, 0.1188 g/lbf 4 - 140 Hz, 0.0576 g/lbf
400m 500m

400m
300m

1 300m
Amplitude g/lbf

Amplitude g/lbf

2
200m
200m
3
100m
100m 1
3
2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTT015 1 - 55 Hz, 0.0641 g/lbf PASS


1 - 100.0 Hz, 0.2470 g/lbf 2 - 70 Hz, 0.0289 g/lbf
2 - 59.5 Hz, 0.2469 g/lbf 3 - 110 Hz, 0.0881 g/lbf
3 - 113.0 Hz, 0.1757 g/lbf 4 - 140 Hz, 0.0537 g/lbf
400m 500m

400m
300m
2 1
300m
Amplitude g/lbf

Amplitude g/lbf

200m 3
200m

100m 3
100m 1
2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1320 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCBA025 1 - 55 Hz, 0.0050 g/lbf PASS


1 - 166.5 Hz, 0.0862 g/lbf 2 - 70 Hz, 0.0029 g/lbf
2 - 160.5 Hz, 0.0791 g/lbf 3 - 110 Hz, 0.0351 g/lbf
3 - 170.0 Hz, 0.0582 g/lbf 4 - 140 Hz, 0.0065 g/lbf
100m 500m
1
2
400m

3 300m
Amplitude g/lbf

Amplitude g/lbf
50m
200m

100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBR025 1 - 55 Hz, 0.0170 g/lbf PASS


1 - 48.5 Hz, 0.0628 g/lbf 2 - 70 Hz, 0.0171 g/lbf
2 - 161.0 Hz, 0.0343 g/lbf 3 - 110 Hz, 0.0116 g/lbf
3 - 83.0 Hz, 0.0333 g/lbf 4 - 140 Hz, 0.0114 g/lbf
80m 500m

1
400m
60m

300m
Amplitude g/lbf

Amplitude g/lbf

40m 2
3
200m

20m
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBT025 1 - 55 Hz, 0.0411 g/lbf PASS


1 - 48.0 Hz, 0.2017 g/lbf 2 - 70 Hz, 0.0253 g/lbf
2 - 132.5 Hz, 0.1177 g/lbf 3 - 110 Hz, 0.0492 g/lbf
3 - 115.0 Hz, 0.1091 g/lbf 4 - 140 Hz, 0.0603 g/lbf
400m 500m

400m
300m

300m
Amplitude g/lbf

Amplitude g/lbf

1
200m
200m
3 2
100m
100m
1 3
2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1321 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCTA025 1 - 55 Hz, 0.0222 g/lbf PASS


1 - 48.0 Hz, 0.0967 g/lbf 2 - 70 Hz, 0.0185 g/lbf
2 - 117.5 Hz, 0.0634 g/lbf 3 - 110 Hz, 0.0299 g/lbf
3 - 115.0 Hz, 0.0609 g/lbf 4 - 140 Hz, 0.0098 g/lbf
100m 1 500m

400m

32
300m
Amplitude g/lbf

Amplitude g/lbf
50m
200m

100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTR025 1 - 55 Hz, 0.0245 g/lbf PASS


1 - 48.0 Hz, 0.1363 g/lbf 2 - 70 Hz, 0.0204 g/lbf
2 - 120.5 Hz, 0.0644 g/lbf 3 - 110 Hz, 0.0299 g/lbf
3 - 83.0 Hz, 0.0510 g/lbf 4 - 140 Hz, 0.0069 g/lbf
200m 500m

400m
1

300m
Amplitude g/lbf

Amplitude g/lbf

100m

2 200m
3
100m
1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTT025 1 - 55 Hz, 0.0330 g/lbf PASS


1 - 48.0 Hz, 0.1952 g/lbf 2 - 70 Hz, 0.0166 g/lbf
2 - 132.5 Hz, 0.1580 g/lbf 3 - 110 Hz, 0.0607 g/lbf
3 - 128.5 Hz,1 0.1268 g/lbf 4 - 140 Hz, 0.0650 g/lbf
200m 500m

2
400m
3
300m
Amplitude g/lbf

Amplitude g/lbf

100m
200m

100m
3
1
2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1322 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCBA026 1 - 55 Hz, 0.0047 g/lbf PASS


1 - 132.0 Hz, 0.0983 g/lbf 2 - 70 Hz, 0.0089 g/lbf
2 - 151.0 Hz, 0.0980 g/lbf 3 - 110 Hz, 0.0322 g/lbf
3 - 165.0 Hz, 0.0941 g/lbf 1 2 4 - 140 Hz, 0.0315 g/lbf
100m 3 500m

400m

300m
Amplitude g/lbf

Amplitude g/lbf
50m
200m

100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBR026 1 - 55 Hz, 0.0250 g/lbf PASS


1 - 102.5 Hz, 0.0749 g/lbf 2 - 70 Hz, 0.0334 g/lbf
2 - 104.0 Hz, 0.0745 g/lbf 3 - 110 Hz, 0.0478 g/lbf
3 - 95.0 Hz, 0.0718 g/lbf 4 - 140 Hz, 0.0076 g/lbf
80m 12 500m
3

400m
60m

300m
Amplitude g/lbf

Amplitude g/lbf

40m
200m

20m
100m
2 3
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBT026 1 - 55 Hz, 0.0555 g/lbf PASS


1 - 64.0 Hz, 0.4781 g/lbf 2 - 70 Hz, 0.2126 g/lbf
2 - 138.5 Hz, 0.2313 g/lbf 3 - 110 Hz, 0.0736 g/lbf
3 - 69.5 Hz, 0.2241 g/lbf 4 - 140 Hz, 0.1866 g/lbf
500m 1 500m

400m 400m

300m 300m
Amplitude g/lbf

Amplitude g/lbf

3 2
2
200m 200m

100m 100m 3
1

0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1323 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCTA026 1 - 55 Hz, 0.0060 g/lbf PASS


1 - 102.5 Hz, 0.0581 g/lbf 2 - 70 Hz, 0.0099 g/lbf
2 - 98.5 Hz, 0.0402 g/lbf 3 - 110 Hz, 0.0178 g/lbf
3 - 189.5 Hz, 0.0389 g/lbf 4 - 140 Hz, 0.0179 g/lbf
80m 500m

1 400m
60m

300m
Amplitude g/lbf

Amplitude g/lbf
2 3
40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTR026 1 - 55 Hz, 0.0356 g/lbf PASS


1 - 102.5 Hz, 0.1241 g/lbf 2 - 70 Hz, 0.0068 g/lbf
2 - 121.5 Hz, 0.1007 g/lbf 3 - 110 Hz, 0.0438 g/lbf
3 - 132.5 Hz, 0.0916 g/lbf 4 - 140 Hz, 0.0275 g/lbf
200m 500m

400m

1
300m
Amplitude g/lbf

Amplitude g/lbf

2
100m 3
200m

100m
1 3
2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTT026 1 - 55 Hz, 0.0523 g/lbf PASS


1 - 64.5 Hz, 0.2776 g/lbf 2 - 70 Hz, 0.0936 g/lbf
2 - 122.0 Hz, 0.2721 g/lbf 3 - 110 Hz, 0.0791 g/lbf
3 - 151.5 Hz, 0.2666 g/lbf 4 - 140 Hz, 0.2082 g/lbf
400m 500m

400m
300m 1 2 3
300m
Amplitude g/lbf

Amplitude g/lbf

200m
200m

100m 2
100m 3
1

0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1324 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCBA027 1 - 55 Hz, 0.0058 g/lbf PASS


1 - 185.0 Hz, 0.1418 g/lbf 2 - 70 Hz, 0.0124 g/lbf
2 - 179.0 Hz, 0.1206 g/lbf 3 - 110 Hz, 0.0228 g/lbf
3 - 171.5 Hz, 0.1172 g/lbf 4 - 140 Hz, 0.0416 g/lbf
200m 500m

400m
1
3 2
300m
Amplitude g/lbf

Amplitude g/lbf
100m
200m

100m

2 3
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBR027 1 - 55 Hz, 0.0061 g/lbf PASS


1 - 185.5 Hz, 0.1689 g/lbf 2 - 70 Hz, 0.0025 g/lbf
2 - 179.5 Hz, 0.1446 g/lbf 3 - 110 Hz, 0.0155 g/lbf
3 - 197.5 Hz, 0.1163 g/lbf 4 - 140 Hz, 0.0351 g/lbf
200m 500m
1
2 400m

3
300m
Amplitude g/lbf

Amplitude g/lbf

100m
200m

100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBT027 1 - 55 Hz, 0.0042 g/lbf PASS


1 - 165.5 Hz, 0.1539 g/lbf 2 - 70 Hz, 0.0119 g/lbf
2 - 162.5 Hz, 0.1481 g/lbf 3 - 110 Hz, 0.0653 g/lbf
3 - 115.0 Hz, 0.1213 g/lbf 4 - 140 Hz, 0.0304 g/lbf
200m 500m

21 400m

3
300m
Amplitude g/lbf

Amplitude g/lbf

100m
200m

100m 3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1325 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCTA027 1 - 55 Hz, 0.0251 g/lbf PASS


1 - 75.5 Hz, 0.4529 g/lbf 2 - 70 Hz, 0.0870 g/lbf
2 - 165.0 Hz, 0.1987 g/lbf 3 - 110 Hz, 0.0287 g/lbf
3 - 152.5 Hz, 0.1893 g/lbf 4 - 140 Hz, 0.0468 g/lbf
500m 500m
1

400m 400m

300m 300m
Amplitude g/lbf

Amplitude g/lbf
3 2
200m 200m

100m 100m 2

1 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTR027 1 - 55 Hz, 0.0348 g/lbf PASS


1 - 68.0 Hz, 0.3922 g/lbf 2 - 70 Hz, 0.1613 g/lbf
2 - 64.0 Hz, 0.2118 g/lbf 3 - 110 Hz, 0.0383 g/lbf
3 - 115.0 Hz, 0.1052 g/lbf 4 - 140 Hz, 0.0326 g/lbf
1
400m 500m

400m
300m

300m
Amplitude g/lbf

Amplitude g/lbf

2
200m
200m
2
3
100m
100m
1 3

0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTT027 1 - 55 Hz, 0.0159 g/lbf PASS


1 - 67.5 Hz, 0.2028 g/lbf 2 - 70 Hz, 0.0771 g/lbf
2 - 192.5 Hz, 0.1060 g/lbf 3 - 110 Hz, 0.0324 g/lbf
3 - 115.0 Hz, 0.0982 g/lbf 4 - 140 Hz, 0.0274 g/lbf
400m 500m

400m
300m

300m
Amplitude g/lbf

Amplitude g/lbf

1
200m
200m
3 2
100m
100m 2
3
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1326 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCBA037 1 - 55 Hz, 0.0047 g/lbf PASS


1 - 157.0 Hz, 0.2239 g/lbf 2 - 70 Hz, 0.0099 g/lbf
2 - 149.0 Hz, 0.1457 g/lbf 3 - 110 Hz, 0.0394 g/lbf
3 - 170.5 Hz, 0.0941 g/lbf 4 - 140 Hz, 0.0728 g/lbf
400m 500m

400m
300m

1 300m
Amplitude g/lbf

Amplitude g/lbf
200m
2 200m

100m 3
100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBR037 1 - 55 Hz, 0.0257 g/lbf PASS


1 - 133.0 Hz, 0.1970 g/lbf 2 - 70 Hz, 0.0236 g/lbf
2 - 157.5 Hz, 0.1639 g/lbf 3 - 110 Hz, 0.0572 g/lbf
3 - 137.5 Hz, 0.1632 g/lbf 4 - 140 Hz, 0.1328 g/lbf
1
200m 500m
3 2
400m

300m
Amplitude g/lbf

Amplitude g/lbf

100m
200m

100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBT037 1 - 55 Hz, 0.0113 g/lbf PASS


1 - 93.0 Hz, 0.2508 g/lbf 2 - 70 Hz, 0.0297 g/lbf
2 - 87.0 Hz, 0.1505 g/lbf 3 - 110 Hz, 0.0545 g/lbf
3 - 174.5 Hz, 0.1245 g/lbf 4 - 140 Hz, 0.0940 g/lbf
400m 500m

400m
300m
1
300m
Amplitude g/lbf

Amplitude g/lbf

200m
2 200m
3
100m
100m
3
2
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1327 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCTA037 1 - 55 Hz, 0.0929 g/lbf PASS


1 - 178.5 Hz, 0.1945 g/lbf 2 - 70 Hz, 0.0136 g/lbf
2 - 180.5 Hz, 0.1711 g/lbf 3 - 110 Hz, 0.0427 g/lbf
3 - 187.0 Hz, 0.1677 g/lbf 1 4 - 140 Hz, 0.0097 g/lbf
200m 500m
23
400m

300m
Amplitude g/lbf

Amplitude g/lbf
100m
200m

1
100m
3
2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTR037 1 - 55 Hz, 0.0123 g/lbf PASS


1 - 83.0 Hz, 0.2802 g/lbf 2 - 70 Hz, 0.0820 g/lbf
2 - 44.5 Hz, 0.1931 g/lbf 3 - 110 Hz, 0.0782 g/lbf
3 - 72.5 Hz, 0.1402 g/lbf 4 - 140 Hz, 0.0690 g/lbf
400m 500m

400m
300m 1

300m
Amplitude g/lbf

Amplitude g/lbf

2
200m
3 200m

100m
100m 2 3

1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTT037 1 - 55 Hz, 0.0880 g/lbf PASS


1 - 133.0 Hz, 0.2103 g/lbf 2 - 70 Hz, 0.0212 g/lbf
2 - 131.0 Hz, 0.1995 g/lbf 3 - 110 Hz, 0.0237 g/lbf
3 - 40.0 Hz, 0.1911 g/lbf 4 - 140 Hz, 0.1399 g/lbf
400m 500m

400m
300m

300m
Amplitude g/lbf

Amplitude g/lbf

3 21
200m
200m

100m 1
100m
2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1328 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCBA038 1 - 55 Hz, 0.0075 g/lbf PASS


1 - 139.0 Hz, 0.1085 g/lbf 2 - 70 Hz, 0.0129 g/lbf
2 - 108.5 Hz, 0.0997 g/lbf 3 - 110 Hz, 0.0852 g/lbf
3 - 112.0 Hz, 0.0795 g/lbf 4 - 140 Hz, 0.1030 g/lbf
200m 500m

400m

300m
Amplitude g/lbf

Amplitude g/lbf
1
2
100m
3
200m

100m 3

1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBR038 1 - 55 Hz, 0.0368 g/lbf PASS


1 - 44.5 Hz, 0.1099 g/lbf 2 - 70 Hz, 0.0133 g/lbf
2 - 57.0 Hz, 0.0673 g/lbf 3 - 110 Hz, 0.0407 g/lbf
3 - 83.0 Hz, 0.0523 g/lbf 4 - 140 Hz, 0.0248 g/lbf
200m 500m

400m

1 300m
Amplitude g/lbf

Amplitude g/lbf

100m
2 200m
3
100m
1 3
2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBT038 1 - 55 Hz, 0.1997 g/lbf PASS


1 - 56.5 Hz, 0.2411 g/lbf 2 - 70 Hz, 0.0243 g/lbf
2 - 54.5 Hz, 0.2170 g/lbf 3 - 110 Hz, 0.1452 g/lbf
3 - 40.0 Hz, 0.1994 g/lbf 4 - 140 Hz, 0.0755 g/lbf
400m 500m

400m
300m
1
300m
Amplitude g/lbf

Amplitude g/lbf

2
3
200m
1
200m
3
100m
100m
2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1329 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCTA038 1 - 55 Hz, 0.0080 g/lbf PASS


1 - 73.0 Hz, 0.0368 g/lbf 2 - 70 Hz, 0.0230 g/lbf
2 - 194.5 Hz, 0.0339 g/lbf 3 - 110 Hz, 0.0276 g/lbf
3 - 118.5 Hz, 0.0310 g/lbf 4 - 140 Hz, 0.0095 g/lbf
40m 1 500m
2
3 400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf
20m
200m

10m
100m
2 3
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTR038 1 - 55 Hz, 0.0130 g/lbf PASS


1 - 157.5 Hz, 0.1316 g/lbf 2 - 70 Hz, 0.0271 g/lbf
2 - 83.0 Hz, 0.1290 g/lbf 3 - 110 Hz, 0.0298 g/lbf
3 - 94.0 Hz, 0.1268 g/lbf 4 - 140 Hz, 0.0162 g/lbf
200m 500m

400m
2 3 1
300m
Amplitude g/lbf

Amplitude g/lbf

100m
200m

100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTT038 1 - 55 Hz, 0.1829 g/lbf PASS


1 - 56.5 Hz, 0.2283 g/lbf 2 - 70 Hz, 0.0522 g/lbf
2 - 54.5 Hz, 0.1934 g/lbf 3 - 110 Hz, 0.0648 g/lbf
3 - 40.5 Hz, 0.1899 g/lbf 4 - 140 Hz, 0.0494 g/lbf
400m 500m

400m
300m

1 300m
Amplitude g/lbf

Amplitude g/lbf

3 2
200m
200m 1

100m
100m 3
2

0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1330 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCBA039 1 - 55 Hz, 0.0023 g/lbf PASS


1 - 170.0 Hz, 0.0500 g/lbf 2 - 70 Hz, 0.0055 g/lbf
2 - 169.0 Hz, 0.0490 g/lbf 3 - 110 Hz, 0.0195 g/lbf
3 - 157.5 Hz, 0.0464 g/lbf 4 - 140 Hz, 0.0157 g/lbf
80m 500m

400m
60m
21
3 300m
Amplitude g/lbf

Amplitude g/lbf
40m
200m

20m
100m

2 3
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBR039 1 - 55 Hz, 0.0122 g/lbf PASS


1 - 88.5 Hz, 0.1302 g/lbf 2 - 70 Hz, 0.0123 g/lbf
2 - 149.0 Hz, 0.0546 g/lbf 3 - 110 Hz, 0.0340 g/lbf
3 - 133.5 Hz, 0.0512 g/lbf 4 - 140 Hz, 0.0275 g/lbf
200m 500m

400m
1
300m
Amplitude g/lbf

Amplitude g/lbf

100m
200m
3 2

100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBT039 1 - 55 Hz, 0.0106 g/lbf PASS


1 - 87.5 Hz, 0.2757 g/lbf 2 - 70 Hz, 0.0280 g/lbf
2 - 93.5 Hz, 0.1249 g/lbf 3 - 110 Hz, 0.0913 g/lbf
3 - 110.0 Hz, 0.0913 g/lbf 4 - 140 Hz, 0.0307 g/lbf
400m 500m

400m
300m 1

300m
Amplitude g/lbf

Amplitude g/lbf

200m
200m
2
100m 3
100m 3

2
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1331 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCTA039 1 - 55 Hz, 0.0041 g/lbf PASS


1 - 170.0 Hz, 0.1742 g/lbf 2 - 70 Hz, 0.0114 g/lbf
2 - 87.5 Hz, 0.0828 g/lbf 3 - 110 Hz, 0.0194 g/lbf
3 - 187.5 Hz, 0.0813 g/lbf 4 - 140 Hz, 0.0181 g/lbf
200m 500m
1
400m

300m
Amplitude g/lbf

Amplitude g/lbf
100m
2 3
200m

100m

2 3
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTR039 1 - 55 Hz, 0.0099 g/lbf PASS


1 - 88.0 Hz, 0.1662 g/lbf 2 - 70 Hz, 0.0182 g/lbf
2 - 148.5 Hz, 0.1013 g/lbf 3 - 110 Hz, 0.0276 g/lbf
3 - 127.5 Hz, 0.0728 g/lbf 4 - 140 Hz, 0.0320 g/lbf
200m 500m
1
400m

300m
Amplitude g/lbf

Amplitude g/lbf

2
100m
3 200m

100m
2 3
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTT039 1 - 55 Hz, 0.0103 g/lbf PASS


1 - 87.5 Hz, 0.2744 g/lbf 2 - 70 Hz, 0.0276 g/lbf
2 - 93.5 Hz, 0.1200 g/lbf 3 - 110 Hz, 0.0764 g/lbf
3 - 110.5 Hz, 0.0779 g/lbf 4 - 140 Hz, 0.0250 g/lbf
400m 500m

400m
300m 1

300m
Amplitude g/lbf

Amplitude g/lbf

200m
200m
2
100m 3
100m 3
2
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1332 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCBA049 1 - 55 Hz, 0.0068 g/lbf PASS


1 - 182.5 Hz, 0.1810 g/lbf 2 - 70 Hz, 0.0132 g/lbf
2 - 179.5 Hz, 0.1538 g/lbf 3 - 110 Hz, 0.0266 g/lbf
3 - 178.0 Hz, 0.1511 g/lbf 4 - 140 Hz, 0.0416 g/lbf
200m 500m
1

32 400m

300m
Amplitude g/lbf

Amplitude g/lbf
100m
200m

100m

2 3
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBR049 1 - 55 Hz, 0.0077 g/lbf PASS


1 - 194.5 Hz, 0.1039 g/lbf 2 - 70 Hz, 0.0222 g/lbf
2 - 189.5 Hz, 0.0928 g/lbf 3 - 110 Hz, 0.0123 g/lbf
3 - 169.0 Hz, 0.0495 g/lbf 4 - 140 Hz, 0.0152 g/lbf
200m 500m

400m

300m
Amplitude g/lbf

Amplitude g/lbf

1
100m 2
200m
3
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBT049 1 - 55 Hz, 0.0056 g/lbf PASS


1 - 168.5 Hz, 0.2993 g/lbf 2 - 70 Hz, 0.0097 g/lbf
2 - 170.0 Hz, 0.2734 g/lbf 3 - 110 Hz, 0.0256 g/lbf
3 - 184.5 Hz, 0.1737 g/lbf 4 - 140 Hz, 0.0685 g/lbf
400m 500m

1 400m
300m 2

300m
Amplitude g/lbf

Amplitude g/lbf

200m 3
200m

100m
100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1333 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCTA049 1 - 55 Hz, 0.1513 g/lbf PASS


1 - 170.0 Hz, 0.1948 g/lbf 2 - 70 Hz, 0.0756 g/lbf
2 - 111.0 Hz, 0.1919 g/lbf 3 - 110 Hz, 0.1849 g/lbf
3 - 169.0 Hz, 0.1900 g/lbf 4 - 140 Hz, 0.0610 g/lbf
200m 2 31 500m

400m

300m
Amplitude g/lbf

Amplitude g/lbf
100m
200m 3
1

100m 2

0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTR049 1 - 55 Hz, 0.0409 g/lbf PASS


1 - 108.0 Hz, 0.1968 g/lbf 2 - 70 Hz, 0.0415 g/lbf
2 - 136.5 Hz, 0.1239 g/lbf 3 - 110 Hz, 0.1535 g/lbf
3 - 134.0 Hz, 0.1211 g/lbf 4 - 140 Hz, 0.1061 g/lbf
1
200m 500m

400m

32
300m
Amplitude g/lbf

Amplitude g/lbf

100m
200m
3

100m
1 2

0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTT049 1 - 55 Hz, 0.0182 g/lbf PASS


1 - 195.0 Hz, 0.0922 g/lbf 2 - 70 Hz, 0.0042 g/lbf
2 - 154.5 Hz, 0.0886 g/lbf 3 - 110 Hz, 0.0635 g/lbf
3 - 190.0 Hz, 0.0757 g/lbf 4 - 140 Hz, 0.0462 g/lbf
100m 1 500m
2

3 400m

300m
Amplitude g/lbf

Amplitude g/lbf

50m
200m

100m 3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1334 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCBA050 1 - 55 Hz, 0.0050 g/lbf PASS


1 - 172.5 Hz, 0.1718 g/lbf 2 - 70 Hz, 0.0064 g/lbf
2 - 176.0 Hz, 0.1714 g/lbf 3 - 110 Hz, 0.0355 g/lbf
3 - 169.0 Hz, 0.1278 g/lbf 4 - 140 Hz, 0.0262 g/lbf
200m 500m
12
400m
3
300m
Amplitude g/lbf

Amplitude g/lbf
100m
200m

100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBR050 1 - 55 Hz, 0.0094 g/lbf PASS


1 - 133.0 Hz, 0.0734 g/lbf 2 - 70 Hz, 0.0284 g/lbf
2 - 73.5 Hz, 0.0665 g/lbf 3 - 110 Hz, 0.0150 g/lbf
3 - 136.5 Hz, 0.0656 g/lbf 4 - 140 Hz, 0.0424 g/lbf
80m 1 500m
2 3
400m
60m

300m
Amplitude g/lbf

Amplitude g/lbf

40m
200m

20m
100m
2
1 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBT050 1 - 55 Hz, 0.0229 g/lbf PASS


1 - 176.0 Hz, 0.6895 g/lbf 2 - 70 Hz, 0.0372 g/lbf
2 - 182.5 Hz, 0.4491 g/lbf 3 - 110 Hz, 0.0510 g/lbf
3 - 153.5 Hz, 0.3375 g/lbf 4 - 140 Hz, 0.0672 g/lbf
800m 500m
1
400m
600m

2 300m
Amplitude g/lbf

Amplitude g/lbf

400m 3
200m

200m
100m
2 3
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1335 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCTA050 1 - 55 Hz, 0.0043 g/lbf PASS


1 - 199.0 Hz, 0.0488 g/lbf 2 - 70 Hz, 0.0088 g/lbf
2 - 195.0 Hz, 0.0456 g/lbf 3 - 110 Hz, 0.0144 g/lbf
3 - 143.5 Hz, 0.0336 g/lbf 4 - 140 Hz, 0.0247 g/lbf
50m 2 500m

40m 400m
3
30m 300m
Amplitude g/lbf

Amplitude g/lbf
20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTR050 1 - 55 Hz, 0.0081 g/lbf PASS


1 - 133.0 Hz, 0.0571 g/lbf 2 - 70 Hz, 0.0213 g/lbf
2 - 73.5 Hz, 0.0536 g/lbf 3 - 110 Hz, 0.0190 g/lbf
3 - 136.0 Hz, 0.0482 g/lbf 4 - 140 Hz, 0.0349 g/lbf
80m 500m

400m
60m 1
2
3
300m
Amplitude g/lbf

Amplitude g/lbf

40m
200m

20m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTT050 1 - 55 Hz, 0.0184 g/lbf PASS


1 - 176.5 Hz, 0.3431 g/lbf 2 - 70 Hz, 0.0307 g/lbf
2 - 178.0 Hz, 0.3365 g/lbf 3 - 110 Hz, 0.0673 g/lbf
3 - 158.0 Hz, 0.2975 g/lbf 4 - 140 Hz, 0.0953 g/lbf
400m 500m
12
3 400m
300m

300m
Amplitude g/lbf

Amplitude g/lbf

200m
200m

100m
100m 3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1336 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCBA051 1 - 55 Hz, 0.0023 g/lbf PASS


1 - 191.0 Hz, 0.0411 g/lbf 2 - 70 Hz, 0.0038 g/lbf
2 - 175.5 Hz, 0.0382 g/lbf 3 - 110 Hz, 0.0106 g/lbf
3 - 196.0 Hz, 0.0350 g/lbf 4 - 140 Hz, 0.0210 g/lbf
50m 500m
1
40m 2 400m
3

30m 300m
Amplitude g/lbf

Amplitude g/lbf
20m 200m

10m 100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBR051 1 - 55 Hz, 0.0025 g/lbf PASS


1 - 197.0 Hz, 0.0338 g/lbf 2 - 70 Hz, 0.0062 g/lbf
2 - 108.5 Hz, 0.0337 g/lbf 3 - 110 Hz, 0.0275 g/lbf
3 - 136.5 Hz, 0.0303 g/lbf 4 - 140 Hz, 0.0171 g/lbf
40m 500m
2 1
3 400m
30m

300m
Amplitude g/lbf

Amplitude g/lbf

20m
200m

10m
100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBT051 1 - 55 Hz, 0.0038 g/lbf PASS


1 - 127.0 Hz, 0.1135 g/lbf 2 - 70 Hz, 0.0068 g/lbf
2 - 133.0 Hz, 0.1089 g/lbf 3 - 110 Hz, 0.0395 g/lbf
3 - 136.0 Hz, 0.0953 g/lbf 4 - 140 Hz, 0.0305 g/lbf
200m 500m

400m

12 300m
Amplitude g/lbf

Amplitude g/lbf

100m 3

200m

100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1337 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCTA051 1 - 55 Hz, 0.0052 g/lbf PASS


1 - 195.5 Hz, 0.1140 g/lbf 2 - 70 Hz, 0.0118 g/lbf
2 - 191.5 Hz, 0.1110 g/lbf 3 - 110 Hz, 0.0558 g/lbf
3 - 128.5 Hz, 0.1002 g/lbf 4 - 140 Hz, 0.0507 g/lbf
200m 500m

400m

21 300m
Amplitude g/lbf

Amplitude g/lbf
3
100m
200m

100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTR051 1 - 55 Hz, 0.0021 g/lbf PASS


1 - 154.0 Hz, 0.0537 g/lbf 2 - 70 Hz, 0.0051 g/lbf
2 - 169.0 Hz, 0.0382 g/lbf 3 - 110 Hz, 0.0257 g/lbf
3 - 170.0 Hz, 0.0369 g/lbf 4 - 140 Hz, 0.0193 g/lbf
80m 500m

400m
60m 1
300m
Amplitude g/lbf

Amplitude g/lbf

40m 23

200m

20m
100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTT051 1 - 55 Hz, 0.0035 g/lbf PASS


1 - 177.0 Hz, 0.0871 g/lbf 2 - 70 Hz, 0.0066 g/lbf
2 - 127.0 Hz, 0.0740 g/lbf 3 - 110 Hz, 0.0299 g/lbf
3 - 154.0 Hz, 0.0734 g/lbf 4 - 140 Hz, 0.0217 g/lbf
100m 500m
1

2 3 400m

300m
Amplitude g/lbf

Amplitude g/lbf

50m
200m

100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1338 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCBA061 1 - 55 Hz, 0.0065 g/lbf PASS


1 - 181.0 Hz, 0.1378 g/lbf 2 - 70 Hz, 0.0099 g/lbf
2 - 145.0 Hz, 0.1064 g/lbf 3 - 110 Hz, 0.0340 g/lbf
3 - 174.0 Hz, 0.0898 g/lbf 4 - 140 Hz, 0.0685 g/lbf
200m 500m

400m
1

300m
Amplitude g/lbf

Amplitude g/lbf
2
100m 3
200m

100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBR061 1 - 55 Hz, 0.0021 g/lbf PASS


1 - 147.0 Hz, 0.1226 g/lbf 2 - 70 Hz, 0.0065 g/lbf
2 - 137.5 Hz, 0.0698 g/lbf 3 - 110 Hz, 0.0202 g/lbf
3 - 112.0 Hz, 0.0329 g/lbf 4 - 140 Hz, 0.0276 g/lbf
200m 500m

400m

1
300m
Amplitude g/lbf

Amplitude g/lbf

100m
2 200m

3 100m

2 3
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBT061 1 - 55 Hz, 0.0028 g/lbf PASS


1 - 159.0 Hz, 0.1105 g/lbf 2 - 70 Hz, 0.0051 g/lbf
2 - 161.0 Hz, 0.1075 g/lbf 3 - 110 Hz, 0.0262 g/lbf
3 - 146.0 Hz, 0.0737 g/lbf 4 - 140 Hz, 0.0317 g/lbf
200m 500m

400m

12 300m
Amplitude g/lbf

Amplitude g/lbf

100m
3 200m

100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1339 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCTA061 1 - 55 Hz, 0.0210 g/lbf PASS


1 - 97.0 Hz, 0.3320 g/lbf 2 - 70 Hz, 0.0340 g/lbf
2 - 88.0 Hz, 0.2631 g/lbf 3 - 110 Hz, 0.1159 g/lbf
3 - 90.0 Hz, 0.2404 g/lbf 4 - 140 Hz, 0.0665 g/lbf
400m 500m
1
400m
300m
2
3
300m
Amplitude g/lbf

Amplitude g/lbf
200m
200m

100m 3
100m
1 2

0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTR061 1 - 55 Hz, 0.0724 g/lbf PASS


1 - 57.5 Hz, 0.3149 g/lbf 2 - 70 Hz, 0.0540 g/lbf
2 - 61.0 Hz, 0.0969 g/lbf 3 - 110 Hz, 0.0341 g/lbf
3 - 52.5 Hz, 0.0798 g/lbf 4 - 140 Hz, 0.0221 g/lbf
400m 500m

1
400m
300m

300m
Amplitude g/lbf

Amplitude g/lbf

200m
200m
2
100m 3
100m 1
2
3

0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTT061 1 - 55 Hz, 0.0711 g/lbf PASS


1 - 57.5 Hz, 0.2594 g/lbf 2 - 70 Hz, 0.0115 g/lbf
2 - 118.0 Hz, 0.1827 g/lbf 3 - 110 Hz, 0.1081 g/lbf
3 - 112.0 Hz, 0.1653 g/lbf 4 - 140 Hz, 0.0606 g/lbf
400m 500m

400m
300m
1
300m
Amplitude g/lbf

Amplitude g/lbf

200m 2
3
200m

100m 3
100m 1
2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1340 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCBA062 1 - 55 Hz, 0.0024 g/lbf PASS


1 - 140.0 Hz, 0.0966 g/lbf 2 - 70 Hz, 0.0080 g/lbf
2 - 151.0 Hz, 0.0841 g/lbf 3 - 110 Hz, 0.0279 g/lbf
3 - 157.0 Hz, 0.0501 g/lbf 4 - 140 Hz, 0.0966 g/lbf
100m 1 500m
2
400m

300m
Amplitude g/lbf

Amplitude g/lbf
3
50m
200m

100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBR062 1 - 55 Hz, 0.0131 g/lbf PASS


1 - 86.5 Hz, 0.1406 g/lbf 2 - 70 Hz, 0.0334 g/lbf
2 - 147.0 Hz, 0.1373 g/lbf 3 - 110 Hz, 0.0334 g/lbf
3 - 140.0 Hz, 0.1344 g/lbf 4 - 140 Hz, 0.1344 g/lbf
200m 500m

400m
1 32
300m
Amplitude g/lbf

Amplitude g/lbf

100m
200m

100m
2 3
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBT062 1 - 55 Hz, 0.0728 g/lbf PASS


1 - 47.0 Hz, 0.4785 g/lbf 2 - 70 Hz, 0.0458 g/lbf
2 - 147.0 Hz, 0.1837 g/lbf 3 - 110 Hz, 0.0213 g/lbf
3 - 39.5 Hz, 0.1534 g/lbf 4 - 140 Hz, 0.1282 g/lbf
500m 1 500m

400m 400m

300m 300m
Amplitude g/lbf

Amplitude g/lbf

200m 2 200m
3

100m 100m 1
2
3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1341 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCTA062 1 - 55 Hz, 0.0010 g/lbf PASS


1 - 140.0 Hz, 0.0329 g/lbf 2 - 70 Hz, 0.0019 g/lbf
2 - 187.5 Hz, 0.0288 g/lbf 3 - 110 Hz, 0.0131 g/lbf
3 - 180.0 Hz, 0.0249 g/lbf 4 - 140 Hz, 0.0329 g/lbf
40m 500m
1
400m
30m 2
3
300m
Amplitude g/lbf

Amplitude g/lbf
20m
200m

10m
100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTR062 1 - 55 Hz, 0.0031 g/lbf PASS


1 - 79.5 Hz, 0.0977 g/lbf 2 - 70 Hz, 0.0274 g/lbf
2 - 76.5 Hz, 0.0714 g/lbf 3 - 110 Hz, 0.0162 g/lbf
3 - 137.0 Hz, 0.0415 g/lbf 4 - 140 Hz, 0.0199 g/lbf
1
100m 500m

400m
2

300m
Amplitude g/lbf

Amplitude g/lbf

50m
3
200m

100m
2 3
1
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTT062 1 - 55 Hz, 0.0347 g/lbf PASS


1 - 47.0 Hz, 0.2535 g/lbf 2 - 70 Hz, 0.0251 g/lbf
2 - 140.0 Hz, 0.2347 g/lbf 3 - 110 Hz, 0.0385 g/lbf
3 - 180.0 Hz, 0.1524 g/lbf 4 - 140 Hz, 0.2347 g/lbf
400m 500m

400m
300m
1
2
300m
Amplitude g/lbf

Amplitude g/lbf

200m
3
200m

100m
100m
1 3
2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1342 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCBA063 1 - 55 Hz, 0.0081 g/lbf PASS


1 - 184.5 Hz, 0.1269 g/lbf 2 - 70 Hz, 0.0095 g/lbf
2 - 186.5 Hz, 0.1240 g/lbf 3 - 110 Hz, 0.0156 g/lbf
3 - 173.0 Hz, 0.0782 g/lbf 4 - 140 Hz, 0.0166 g/lbf
200m 500m

400m
12
300m
Amplitude g/lbf

Amplitude g/lbf
100m
3
200m

100m

1 2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBR063 1 - 55 Hz, 0.0109 g/lbf PASS


1 - 118.0 Hz, 0.1718 g/lbf 2 - 70 Hz, 0.0100 g/lbf
2 - 101.5 Hz, 0.1471 g/lbf 3 - 110 Hz, 0.0473 g/lbf
3 - 97.0 Hz, 0.0855 g/lbf 4 - 140 Hz, 0.0247 g/lbf
200m 500m
1
2 400m

300m
Amplitude g/lbf

Amplitude g/lbf

100m 3
200m

100m
3
1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCBT063 1 - 55 Hz, 0.0748 g/lbf PASS


1 - 86.0 Hz, 0.2362 g/lbf 2 - 70 Hz, 0.0434 g/lbf
2 - 102.0 Hz, 0.2328 g/lbf 3 - 110 Hz, 0.0872 g/lbf
3 - 57.5 Hz, 0.2211 g/lbf 4 - 140 Hz, 0.0537 g/lbf
400m 500m

400m
300m
1 2
3 300m
Amplitude g/lbf

Amplitude g/lbf

200m
200m

100m 3
100m 1
2

0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1343 of 1653


Bump Test_As Left
GENERATOR ENDWINDING RESONANCE TEST
GE Power ENGIE ENERGIA PERU SA
CHILCA UNO POWER STATION
ST 1 GENERATOR 290T818
TEST DATE 02/10/2021
COLLECTOR END PHASE CONNECTION RESPONSES

CEPCTA063 1 - 55 Hz, 0.0133 g/lbf PASS


1 - 151.0 Hz, 0.4642 g/lbf 2 - 70 Hz, 0.0103 g/lbf
2 - 157.0 Hz, 0.4211 g/lbf 3 - 110 Hz, 0.0896 g/lbf
3 - 146.5 Hz, 0.4034 g/lbf 4 - 140 Hz, 0.3490 g/lbf
500m 1 500m
2
3
400m 400m

300m 300m
Amplitude g/lbf

Amplitude g/lbf
200m 200m

100m 100m 3

1 2
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTR063 1 - 55 Hz, 0.0925 g/lbf PASS


1 - 57.5 Hz, 0.3316 g/lbf 2 - 70 Hz, 0.0228 g/lbf
2 - 86.0 Hz, 0.2630 g/lbf 3 - 110 Hz, 0.0300 g/lbf
3 - 118.0 Hz, 0.1007 g/lbf 4 - 140 Hz, 0.0634 g/lbf
400m 500m
1
400m
300m
2
300m
Amplitude g/lbf

Amplitude g/lbf

200m
200m
3
100m 1
100m
2 3
0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

CEPCTT063 1 - 55 Hz, 0.0937 g/lbf PASS


1 - 57.5 Hz, 0.2830 g/lbf 2 - 70 Hz, 0.0502 g/lbf
2 - 117.5 Hz, 0.2804 g/lbf 3 - 110 Hz, 0.0813 g/lbf
3 - 120.0 Hz, 0.2265 g/lbf 4 - 140 Hz, 0.0902 g/lbf
400m 500m

400m
300m 1 2

3 300m
Amplitude g/lbf

Amplitude g/lbf

200m
200m

100m 1
100m 3
2

0 0
0 50 100 150 200 55 80 100 120 140
Frequency - Hz Frequency - Hz

Page 1344 of 1653


GE Power Power Services
map
Wedge
4.5.2
4.5.2 Wedge map
FORM
Part Condition: Good
Part Description:
The Wedge Tightness Assessment was performed using a quantitative analysis technique
where the wedge respond to a mechanical stimulus and measurements are recorded
through the EquoTip measurement tool, that generates a wedge tightness map, with color
code descripted below:

- TIGHT = GREEN
- HOLLOW = YELLOW
- LOOSE = RED

A single wedge was found to be loose. No wedge was found to be hollow, and all other are
green. The results of this test were within the GE recommended acceptable standards for
wedge tightness.

A color-coded wedge tightness map is included with this report.

Recommendation Status: Should be planned for next Outage


Recommendation Description:
The three important elements of a thorough program are maintenance frequency , Visual
Inspection and Electrical testing.
Follow the latest revision of GEK103566 will allow the generator to retain reliability and
avoid major failure expenses.

270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 1345 of 1653
Wedge Map - 290T818

W E D G E : C E > > > T E


1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
S 1 713 803 738 786 717 725 714 710 779 784 763 770 748 765 722 790 769 793 742 784
L 2 723 748 784 769 751 750 735 777 677 769 758 735 698 714 755 734 788 755 771 781
O 3 676 800 766 773 805 694 722 765 737 759 810 769 709 721 808 739 776 775 780 724
T 4 709 806 773 770 745 742 766 724 699 753 731 772 749 744 777 744 734 735 775 683
5 720 768 768 788 758 684 735 723 767 765 754 794 705 744 742 766 779 714 702 770
6 658 784 726 725 756 750 798 789 775 781 732 704 778 676 704 741 717 790 761 734
7 722 718 727 704 718 770 739 742 772 688 716 780 769 695 745 806 763 771 776 777
8 700 764 704 709 688 800 785 766 731 738 715 687 755 720 760 763 709 788 727 818
9 681 771 699 747 752 717 787 722 666 774 720 718 757 719 755 753 722 782 794 785
10 698 730 728 711 704 790 755 719 785 720 799 785 735 732 731 726 789 733 800 748
11 749 680 765 706 802 764 759 753 740 781 722 725 781 696 756 751 786 737 748 776
12 679 803 781 718 769 808 727 756 744 758 731 716 693 722 781 770 699 806 760 784
13 686 710 769 714 801 797 708 768 738 754 724 764 799 753 712 697 727 726 762 801
14 699 744 676 776 800 769 791 802 713 748 775 752 654 773 741 773 714 786 755 768
15 697 741 781 783 766 815 752 783 736 770 762 734 736 728 753 756 752 792 753 711
16 720 758 768 771 766 779 792 779 791 745 762 709 737 778 763 718 778 763 782 777
17 733 751 743 743 772 782 726 799 759 774 778 778 753 778 782 771 725 755 723 710
18 680 773 716 736 712 790 755 793 786 762 784 778 741 750 730 809 799 774 695 766
19 695 784 670 746 806 783 783 788 742 777 735 782 804 763 779 777 777 767 762 816
20 774 701 676 785 785 787 777 747 782 782 781 778 741 762 744 750 744 764 684 742
21 676 742 790 795 801 753 748 745 769 764 729 795 747 757 753 775 781 763 769 728
22 779 733 789 763 796 783 723 759 711 747 756 734 680 678 727 659 704 756 690 704
23 737 740 799 661 767 733 799 719 728 763 756 721 765 777 742 745 714 731 745 705
24 768 661 744 767 746 763 730 751 765 677 699 697 783 717 801 743 754 791 705 730
25 782 786 679 692 757 778 749 695 707 739 681 790 703 753 723 761 749 698 775 686
26 771 716 689 748 787 741 692 752 701 776 782 792 666 749 699 702 713 727 670 771
27 771 724 757 730 787 767 704 717 748 699 697 735 762 744 788 703 779 732 721 759
28 784 786 661 669 705 700 711 715 743 710 727 663 741 781 759 782 679 736 698 720
29 702 710 711 736 716 794 739 666 733 699 753 728 729 681 729 761 784 770 687 712
30 759 713 690 728 737 689 678 762 746 803 757 762 762 763 760 667 658 728 781 714
31 654 704 682 713 683 731 703 738 739 739 702 723 721 736 708 730 739 775 694 690
32 770 787 747 744 776 744 737 791 769 683 687 743 719 699 698 728 761 729 770 763
33 767 710 666 745 719 738 781 737 765 688 746 713 735 784 765 711 706 719 678 724
34 690 720 694 751 783 732 696 778 750 711 677 715 731 713 763 761 781 774 683 665
35 704 767 779 781 677 728 710 741 789 691 691 772 780 732 746 754 789 710 720 740
36 711 704 685 775 699 699 736 743 781 715 766 701 797 758 689 682 795 716 709 740
37 694 676 760 772 764 751 720 783 770 800 753 758 721 675 680 704 739 694 792 747
38 699 654 709 729 760 737 769 684 769 766 661 726 717 757 760 709 711 731 660 671
39 726 703 761 786 732 665 780 726 747 787 767 770 705 695 687 769 790 752 738 748
40 670 673 784 778 725 756 723 799 759 745 775 766 757 753 656 735 708 673 737 751
41 691 723 722 722 715 726 804 761 779 823 787 730 800 743 756 703 695 769 726 720
42 670 774 763 796 761 697 686 756 668 761 737 744 781 743 771 786 756 714 747 753
43 682 780 711 735 788 745 750 695 717 683 734 772 729 765 771 747 747 738 749 749
44 680 779 787 747 690 756 725 776 744 721 706 768 795 811 814 786 780 769 782 729
45 662 782 774 707 727 707 803 779 768 695 790 773 780 775 744 790 738 742 800 751
46 688 742 699 746 779 716 733 763 720 709 725 765 769 732 785 759 702 779 724 756
47 698 764 782 733 787 780 799 733 749 712 746 738 760 770 710 769 708 705 705 767
48 683 687 732 713 721 783 781 775 799 744 703 734 766 784 774 716 724 677 738 777
49 688 687 748 715 688 758 713 798 788 753 757 773 800 732 729 736 743 744 768 777
50 689 761 762 739 783 787 756 678 738 777 762 762 719 765 723 676 756 759 769 737
51 704 781 711 783 686 714 725 790 745 711 740 788 763 736 776 763 694 719 738 781
52 721 697 705 752 728 781 792 777 784 747 773 728 736 783 738 712 770 783 754 734
53 738 798 711 696 747 714 713 789 757 751 780 794 724 748 715 776 758 765 788 767
54 660 759 748 704 781 731 729 746 742 772 740 758 800 749 713 693 738 720 765 726
55 659 770 705 757 742 735 724 783 674 716 758 727 705 734 768 765 761 743 765 703
56 675 788 759 755 768 734 799 730 688 744 789 786 710 792 785 771 726 780 712 762
57 697 751 722 801 733 789 715 761 790 779 794 746 732 777 709 758 749 761 715 716

Page 1346 of 1653


Wedge Map - 290T818

58 672 784 747 716 688 689 731 789 736 754 757 733 775 779 709 681 732 773 775 782
59 663 726 760 765 695 719 779 767 719 761 786 787 765 758 746 783 675 744 762 691
60 657 773 792 727 722 766 765 713 742 778 714 776 722 781 753 757 747 745 733 766
61 653 723 729 692 702 717 753 736 709 757 756 804 758 742 764 753 768 742 792 757
62 665 792 743 774 774 703 780 800 739 745 690 753 797 744 784 748 707 722 777 733
63 699 758 759 791 755 753 768 771 755 766 781 746 801 724 714 771 786 688 736 714
64 764 757 756 770 774 728 765 787 765 763 788 709 698 751 739 758 782 751 717 776
65 739 773 753 713 758 787 781 776 758 781 762 776 782 771 794 757 776 777 752 713
66 703 680 808 726 729 788 754 788 772 769 774 775 774 736 735 793 801 709 703 726
67 756 761 774 695 761 789 757 791 733 795 764 761 737 791 753 798 776 792 706 722
68 756 709 748 732 675 735 780 766 813 814 792 762 736 719 759 787 755 769 768 741
69 721 770 742 746 757 769 762 789 715 734 762 761 764 705 759 787 785 733 712 706
70 743 771 755 746 782 769 743 741 797 797 734 736 742 750 747 771 753 744 720 763
71 708 764 776 776 758 804 717 767 744 739 760 780 727 728 790 725 756 751 711 740
72 733 747 761 790 764 772 750 768 736 720 772 774 809 721 689 796 733 682 680 783

Page 1347 of 1653


Wedge Map - 290T818

21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36
757 756 726 794 756 766 767 795 726 770 778 767 745 801 778 675
775 753 750 775 710 773 804 726 766 762 799 766 732 726 793 665
767 798 776 779 788 759 794 742 812 808 771 755 782 763 788 667
778 780 764 774 767 761 743 765 779 742 770 771 728 738 757 695
719 747 757 765 775 708 740 773 794 740 695 733 741 742 791 665
783 791 694 768 763 711 781 737 731 778 774 792 739 783 747 658
766 725 727 755 804 686 806 712 787 747 761 740 728 778 742 677
807 755 720 733 758 779 733 739 746 757 686 749 750 761 753 708
766 743 522 780 763 741 706 749 763 767 748 758 768 741 769 748
792 689 782 721 691 717 742 744 775 760 708 720 776 773 765 724
777 766 734 720 709 719 763 785 710 772 695 761 767 723 754 740
766 737 776 753 702 768 755 757 788 770 713 757 759 714 739 752
753 780 800 706 727 757 787 803 707 770 737 774 753 708 729 707
755 750 753 764 760 776 720 798 798 712 714 765 775 759 729 722
754 737 758 750 769 756 776 776 678 774 780 790 745 714 719 731
757 739 773 780 716 750 769 751 758 766 720 755 768 770 719 754
761 725 733 724 777 770 752 743 796 744 769 764 731 771 754 684
753 734 777 774 759 773 774 720 779 801 775 745 722 745 722 752
778 729 757 770 755 746 724 767 801 730 775 720 741 749 796 703
767 763 751 778 717 672 742 765 808 803 767 776 764 764 774 731
768 716 663 773 756 761 730 720 697 710 786 721 773 710 807 706
732 724 754 772 745 729 761 682 698 704 727 743 719 738 721 785
756 730 672 726 695 676 724 714 761 690 685 710 719 689 742 803
728 753 700 712 735 757 704 761 750 777 691 732 687 727 697 785
743 747 752 771 772 743 733 705 692 737 776 683 718 732 699 730
664 763 704 701 777 769 729 676 732 719 731 716 686 712 700 753
743 727 715 766 699 707 722 715 759 671 734 796 678 784 746 663
736 708 709 735 692 738 778 747 691 728 731 722 734 726 720 719
669 664 663 719 739 765 746 793 712 678 731 729 744 719 747 725
724 726 749 701 765 744 720 695 743 760 707 756 720 713 732 705
779 758 753 766 721 736 715 694 730 692 711 680 703 673 768 652
757 696 728 716 713 726 697 713 731 734 686 764 675 767 763 684
700 692 736 775 719 744 735 717 707 769 711 674 763 779 796 729
700 682 765 714 739 710 693 763 700 687 704 707 736 789 704 770
700 764 768 763 693 734 751 690 701 707 699 730 758 744 780 754
723 705 742 767 729 754 751 753 735 688 731 697 719 686 716 710
740 704 722 727 712 747 715 720 769 719 766 695 711 709 742 659
743 699 666 747 725 735 775 730 802 678 706 702 771 714 728 725
738 711 681 673 758 697 695 740 738 691 707 724 708 772 777 707
726 687 745 767 731 798 731 784 757 770 730 668 714 688 795 750
697 751 729 698 741 717 739 754 701 739 731 712 691 701 718 776
784 768 725 769 751 794 751 769 758 759 732 727 704 756 747 693
684 720 788 756 753 761 741 747 717 733 732 718 735 734 763 691
680 729 768 784 693 746 754 702 708 734 702 795 738 706 775 721
716 757 773 801 767 765 749 772 737 824 701 735 698 743 774 721
695 724 726 772 726 792 773 791 756 764 712 791 740 705 764 655
711 756 805 766 787 770 761 719 807 752 741 740 680 717 797 661
762 773 749 736 744 774 688 786 770 692 718 730 727 721 779 686
699 759 742 726 695 721 750 801 753 762 729 710 755 723 711 689
739 763 779 781 754 731 756 774 730 739 712 734 711 673 735 690
738 718 796 770 724 746 784 765 749 729 734 782 749 780 769 677
709 788 793 774 705 787 795 785 757 795 756 758 751 766 766 722
792 743 760 715 788 772 769 746 757 750 774 730 744 794 771 736
753 777 711 759 765 717 711 701 753 796 786 729 780 681 765 734
774 776 773 730 715 722 775 753 763 776 749 749 742 707 717 756
785 784 751 715 718 716 740 757 727 724 776 731 736 756 786 730
766 776 735 751 768 763 733 744 752 781 758 707 787 772 702 811

Page 1348 of 1653


Wedge Map - 290T818

749 734 713 788 732 768 741 728 718 743 746 720 763 733 743 762
773 734 727 700 752 747 753 780 770 797 784 796 740 745 779 698
712 758 778 779 798 769 755 768 701 746 747 741 764 752 770 746
739 788 769 806 777 748 786 753 754 752 729 764 749 805 782 792
760 765 794 739 750 743 741 737 760 753 746 724 762 780 760 711
745 705 751 677 697 739 782 755 761 758 791 680 798 754 760 750
735 707 782 658 757 752 809 795 747 763 677 796 715 750 778 764
755 705 713 725 784 670 790 768 724 747 701 752 722 793 790 766
792 783 741 733 753 742 778 794 752 714 778 738 734 719 776 737
724 759 691 770 732 706 738 732 765 779 739 773 805 758 760 742
773 732 743 784 738 725 765 739 769 727 754 721 716 795 767 785
736 673 767 749 757 720 769 723 754 736 763 743 774 792 781 696
753 767 735 757 768 762 806 784 773 790 744 775 770 737 748 763
759 721 775 757 712 777 781 781 734 778 726 790 776 800 770 761
769 763 785 800 752 749 789 778 762 720 753 792 759 731 784 762

Page 1349 of 1653


GE Power Power Services
ELCID
4.5.3
4.5.3 ELCID
FORM
Part Description:
An ELCID test was performed establishing 4% of the normal flux density in the core in order
to search for inconsistent flux patterns caused by fault currents due to shorted core
laminations.

The ELCID compared the flux density at all locations to a reference signal. Flux density
throughout the core was consistent and it showed that there were no problems and no
deviation between the reference and the local sign was picked up by the test set. All readings
were below 100mA and the stator core was considered approved as satisfactory.

Recommendation Status: Should be planned for next Outage


Recommendation Description:
The three important elements of a thorough program are maintenance frequency , Visual
Inspection and Electrical testing.
Follow the latest revision of GEK103566 will allow the generator to retain reliability and
avoid major failure expenses.

ELCID Picture

270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 1350 of 1653
CHILCA UNO - ENGIE - ELCID_results

ELCID Test Data


Baseline ELCID
Date 02/01/2021 Turbine Serial No. 270T818 Prepared by: Renan Lopes / Erica Koono
Generator Serial No. 290T818 Customer: Engie - GE
Station: Chilca Uno

Heading

Power Generation Services

Comments:
Final EL-CID testing.

Page 1351 of 1653


CHILCA UNO - ENGIE - ELCID_results

ELCID Test Data


Baseline ELCID
Date 1/2/2021 Turbine Serial No. 270T818 Prepared by: Renan Lopes / Erica Koono
Generator Serial No. 290T818 Customer: Engie - GE
Station: Chilca Uno

Description of test

The Black trace indicates the trolley movement was from the CE (Collector
End) to TE (Turbine End).

The Blue trace indicates the trolley movement was from the TE (Turbine
End) to CE (Collector End).

Red color indicates > 100 milliamp trace.

No slot had any indications equal to or greater than 100 mA during this test.
The following page (peaks) indicates the highest readings during the
performance of the test.

Y axis indications milliamps, X axis is axial location in the core.

Power Generation Services

Comments:

Page 1352 of 1653


CHILCA UNO - ENGIE - ELCID_results

ELCID Test Data


Baseline ELCID
Date 1/2/2021 Turbine Serial No. 270T818 Prepared by: Renan Lopes / Erica Koono
Generator Serial No. 290T818 Customer: Engie - GE
Station: Chilca Uno

Highest Peaks Recorded

Power Generation Services

Comments:

Page 1353 of 1653


CHILCA UNO - ENGIE - ELCID_results

ELCID Test Data


Baseline ELCID
Date 1/2/2021 Turbine Serial No. 270T818 Prepared by: Renan Lopes / Erica Koono
Generator Serial No. 290T818 Customer: Engie - GE
Station: Chilca Uno

Slots 1-6

Page 1354 of 1653


CHILCA UNO - ENGIE - ELCID_results

ELCID Test Data


Baseline ELCID
Date 1/2/2021 Turbine Serial No. 270T818 Prepared by: Renan Lopes / Erica Koono
Generator Serial No. 290T818 Customer: Engie - GE
Station: Chilca Uno

Slots 7-12

Page 1355 of 1653


CHILCA UNO - ENGIE - ELCID_results

ELCID Test Data


Baseline ELCID
Date 1/2/2021 Turbine Serial No. 270T818 Prepared by: Renan Lopes / Erica Koono
Generator Serial No. 290T818 Customer: Engie - GE
Station: Chilca Uno

Slots 13-18

Page 1356 of 1653


CHILCA UNO - ENGIE - ELCID_results

ELCID Test Data


Baseline ELCID
Date 1/2/2021 Turbine Serial No. 270T818 Prepared by: Renan Lopes / Erica Koono
Generator Serial No. 290T818 Customer: Engie - GE
Station: Chilca Uno

Slots 19-24

Page 1357 of 1653


CHILCA UNO - ENGIE - ELCID_results

ELCID Test Data


Baseline ELCID
Date 1/2/2021 Turbine Serial No. 270T818 Prepared by: Renan Lopes / Erica Koono
Generator Serial No. 290T818 Customer: Engie - GE
Station: Chilca Uno

Slots 25-30

Page 1358 of 1653


CHILCA UNO - ENGIE - ELCID_results

ELCID Test Data


Baseline ELCID
Date 1/2/2021 Turbine Serial No. 270T818 Prepared by: Renan Lopes / Erica Koono
Generator Serial No. 290T818 Customer: Engie - GE
Station: Chilca Uno

Slots 31-36

Page 1359 of 1653


CHILCA UNO - ENGIE - ELCID_results

ELCID Test Data


Baseline ELCID
Date 1/2/2021 Turbine Serial No. 270T818 Prepared by: Renan Lopes / Erica Koono
Generator Serial No. 290T818 Customer: Engie - GE
Station: Chilca Uno

Slots 37-42

Page 1360 of 1653


CHILCA UNO - ENGIE - ELCID_results

ELCID Test Data


Baseline ELCID
Date 1/2/2021 Turbine Serial No. 270T818 Prepared by: Renan Lopes / Erica Koono
Generator Serial No. 290T818 Customer: Engie - GE
Station: Chilca Uno

Slots 43-48

Page 1361 of 1653


CHILCA UNO - ENGIE - ELCID_results

ELCID Test Data


Baseline ELCID
Date 1/2/2021 Turbine Serial No. 270T818 Prepared by: Renan Lopes / Erica Koono
Generator Serial No. 290T818 Customer: Engie - GE
Station: Chilca Uno

Slots 49-54

Page 1362 of 1653


CHILCA UNO - ENGIE - ELCID_results

ELCID Test Data


Baseline ELCID
Date 1/2/2021 Turbine Serial No. 270T818 Prepared by: Renan Lopes / Erica Koono
Generator Serial No. 290T818 Customer: Engie - GE
Station: Chilca Uno

Slots 55-60

Page 1363 of 1653


CHILCA UNO - ENGIE - ELCID_results

ELCID Test Data


Baseline ELCID
Date 1/2/2021 Turbine Serial No. 270T818 Prepared by: Renan Lopes / Erica Koono
Generator Serial No. 290T818 Customer: Engie - GE
Station: Chilca Uno

Slots 61-66

Page 1364 of 1653


CHILCA UNO - ENGIE - ELCID_results

ELCID Test Data


Baseline ELCID
Date 1/2/2021 Turbine Serial No. 270T818 Prepared by: Renan Lopes / Erica Koono
Generator Serial No. 290T818 Customer: Engie - GE
Station: Chilca Uno

Slots 67-72

Page 1365 of 1653


GE Power Power Services
Agreement
Test
Voltage
High
4.5.4
4.5.4 High Voltage Test Agreement
FORM
Part Description:
High Voltage Test Agreement between Engie and GE was made in order to advise
customer the values of the test that will be performed on the unit and that possible failures
can occur on marginal winding. Based on this, it was decided that just left and Right phases
would be tested as center phases didn't have acceptable values to be tested.

270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 1366 of 1653
d316218 - Hipotential Testing Agreem…

Hipotential Testing Agreement


Stator - Test and Inspection
Date: 10/02/2021 Generator Serial No. 290T818 Prepared by: Renan Lopes

Customer: ENGIE -Chilca 1 Turbine Serial No. 270T818 Project ID: ERP-10339092

Generator Rated Voltage (E): 18.0 KV

STATOR TESTING (Put an "X" in the box(s) of the test(s) to be performed)


X 1) DC Leakage Test [TM2040]
2) AC Hipotential Test (60 Hz) [TM2050]
NA 3) AC Hipotential Test (0.1 Hz) [TM2050] - NO LONGER OFFERED
x 4) DC Hipotential Test [TM2050]

OVER VOLTAGE PROOF TESTING

GE RECOMMENDED TEST VOLTAGES (1.5E)


Multiplier Conversion Factors
DC Leakage Test [TM2040]: 2.0 36.0 KV DC
AC Hipot Test (60 Hz) [TM2050]: 1.5 KV AC
AC Hipot Test (0.1 Hz) [TM2050]: No longer offered NA KV AC
DC Hipot Test [TM2050]: 1.5 1.7 45.9 KV DC

X I agree with the use of the above GE Recommended Test Voltages for this unit. LZA (Initials)

I disagree with the use of the above GE Recommended Test Voltages. I understand that IEEE (Initials)
95-2002 recommends 1.25E to 1.5E AC RMS for a hipot test value. I request the following:

CUSTOMER REQUESTED VALUE (Multiplier) FOR DC LEAKAGE TESTING:

CUSTOMER REQUESTED VALUE (Multiplier) FOR AC/DC HIPOT TESTING:

CUSTOMER REQUESTED TEST VOLTAGES


Multiplier Conversion Factors
DC Leakage Test [TM2040]: KV DC
AC Hipot Test (60 Hz) [TM2050]: KV AC
AC Hipot Test (0.1 Hz) [TM2050]: No longer offered NA KV AC
DC Hipot Test [TM2050]: 1.7 KV DC

X Customer Requested Test Voltage KV DC (DC Leakage) (Initials)

Customer Requested Test Voltage KV AC (60 Hz) (Initials)

NA Customer Requested Test Voltage NA KV AC (0.1 Hz) NA (Initials)

x Customer Requested Test Voltage KV DC (Initials)

Print Full Name Luis Zambrano Title Jefe de Mantenimiento CT Chilca


Signature Date 24-02-2021

Solo considerar pruebas de DC leakage test a la fases R y T mas no la fase S, la prueba


debe ser gradual hasta llegar a 36 KV y en caso de detactar fugas para la pruebas y comuicar.

GE Proprietary and Confidential Information. Not to be distributed or reproduced to third parties without prior GE approval
D316218 Sheet: Test & Inspect Rev 2.2 - 02/12/2020

Page 1367 of 1653


GE Power Power Services
Resistance
Widing
Armature
4.5.5
4.5.5 Armature Widing Resistance
FORM
Part Description:
Winding resistances were taken with a Digital Low Resistance Ohm Meter (DLRO) to obtain
the desired accuracy in the low resistance ranges associated with stator windings. No
differences were observed in the copper resistance of the stator phases. The spread of
copper resistance readings between the phases should be within 1% and/ or when
comparing to factory test results, each phase should be within +/- 2% of the original factory
measurement for that phase. The winding resistance results were found to be satisfactory.

Recommendation Status: Should be planned for next Outage


Recommendation Description:
The three important elements of a thorough program are maintenance frequency , Visual
Inspection and Electrical testing.
Follow the latest revision of GEK103566 will allow the generator to retain reliability and avoid
major failure expenses.

270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 1368 of 1653
D3162041 - Armature Winding Resist…

Armature Winding Resistance


Equip Code 324 Dual Terminal - TE
Date (m/d/y) 24/2/21 Turbine Serial No. 270T818 Prepared by Renan Lopes
Generator Serial No. 290T818 ERP Project ID 10339092

Applicable Figure FIG 6 A B C D E F


Terminal Position In Figure T3 T2 T1 T6 T5 T4

Terminal Labels Left Center Right Line or Neutral Terminals


Turbine End T6 T5 T4 Neutral Terminals
Collector End T3 T2 T1 Line Terminals
Customer Designation
Resistance 0.000954 0.000952 0.000953 Temp ºC 35
Resistance Corrected to 25ºC 0.000919 0.000917 0.000918
Factory Resistance at 25ºC 0.000900 0.000900 0.000900 Fact. Or Calc. Selection Factory
Prior Test Correct to 25ºC Date (mm/dd/yy)
Test Equipment Information Rule A B C
Serial No. of Equipment 101880611 1 Pass
Calibration date 8/6/2020 2
Calibration Due Date 8/7/2021 3 Pass Pass Pass
4 NA NA NA
Rules:
1. The spread of copper resistance readings between the phases should be within 1%.
2. When comparing to historical test results each phase should be within +/- 1% of the previous
reading for that phase.
3. When comparing to factory test results, each phase should be within +/- 2% of the original factory
measurement for that phase.
4. When comparing to calculated values, each phase should be within +/- 5% of the calculated
resistance for that phase.

Comments

GE Proprietary and Confidential Information. Not to be distributed or reproduced to third parties without prior GE approval
D3162041 Sheet: (a) Rev 2.2 - 03/11/2020

Page 1369 of 1653


GE Power Power Services
Resistance
Insulation
Armature
4.5.6
4.5.6 Armature Insulation Resistance
FORM
Part Description:
The purpose of this test is to determine the integrity of the insulation system. Insulation
Resistance at Left and Right phases show a good insulation system if values over 1GOhm in
the 1º minute Plus, the PI was greater than 2 on those phases. Although, center phase
failed the test presenting both low Polarization Index and low MOhm absolute value.

Visual inspection and troubleshooting tests were made in order to find the possible reason
for the low values on center phase. Although, we couldn't get the center phase to have
acceptable values according to GE standards

Recommendation Status: Should be done immediately


Recommendation Description:
Below recommendations from GE engineer to be done immediately after outage finish :

"Luego de varios días de tratamiento térmico en los cuales se incrementó la temperatura del
estator hasta los 60C, hemos evidenciado una mejora en la resistencia de aislamiento (IR),
sin embargo el índice de polarización (PI) no aumenta y la tendencia se ha mantenido
estática en las últimas 48 horas.

En esta condición, ENGIE, bajo su cuenta y riesgo, podría considerar las siguientes
acciones para intentar mejorar los parámetros eléctricos actuales en la fase S del estator del
generador:

1. Detener el tratamiento térmico del generador (retirar calefactores y


deshumidificadores).
2. Efectuar nuevamente la limpieza de terminales y bushings, y hacer megado para
cumplir con lo recomendado y solicitado por LABOREC
3. Completar las pruebas eléctricas en la fase R y T
4. Hacer un megger más a 5000 volts, cuando la máquina esté fría y antes de pintar.
5. Completar las pruebas eléctricas en la fase R y T.
6. Completar la pintura de acabado del generador (flooding)
7. Efectuar el rearme mecánico del generador, completar las conexiones eléctricas y
rellenarlo con hidrogeno.
8. Poner la unidad en servicio en mínimo técnico (120 MW), monitoreando
continuamente las descargas parciales, durante 48 horas. Durante este periodo de
prueba, se debe mantener bajo el aporte de reactivos.
9. Una vez completado este periodo de 48 horas, detener la unidad y efectuar pruebas
eléctricas de IR y PI.
Con los resultados de estas mediciones, evaluaremos nuevamente la condición del
generador y podríamos proporcionar una recomendación técnica respecto al regreso del

270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 1370 of 1653
GE Power Power Services

4.5.6 Armature Insulation Resistance


FORM
turbogenerador a operación comercial."

270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 1371 of 1653
d3162043 - Stator Winding Insulation …
Stator Winding Insulation Resistance / HV Proof Tests
Generator Test & Inspection
Date 02/24/2021 Generator No.: 290T818 Prepared by: Renan Lopes / Erica Koono
Equipment 324 Marina Anders / Marília Oliveira
OEM GE Stator Voltage (kV): 18.0 Project ID: 10339092
DC INSULATION RESISTANCE (Megohms) per TM2030
Voltage: 5000 Volts
Time(Min) Left (CE) Center (CE) Right (CE) 10 Minute Insulation Resistance
0.5 1083 397 1172
1.0 2050 470 2210 14000
2.0 3560 516 3690
3.0 4940 536 4950 12000
4.0 6150 544 5940
5.0 7490 550 6990 M 10000
E
6.0 8720 552 7850
G
7.0 10110 557 8860 8000
O
8.0 10810 556 9800 H
9.0 12160 557 10370 M 6000
10.0 13190 558 11080 S

PI 6.4 1.2 5.0 4000


Rule 1 PASS FAIL PASS
Rule 2 PASS FAIL PASS 2000
After Hipot1 min 2330 1993
0
Rule 3 PASS PASS
0.0 2.0 4.0 6.0 8.0 10.0 12.0

Conditions During Insulation Resistance TIME (Min.)

Winding Temperature (oC) 35 Left (CE) Center (CE) Right (CE)


Ambient Tempature (oC) 25
Relative Humidity (%) 68%
Insulation Type Thermal Setting (i.e. Micapal, Isotenax, >1960)
Corrected Resistance1 minute at 40°C IEC 60034-27 Left (CE) 2050 Center (CE) 470 Right (CE) 2210 Megohms
HIGH VOLTAGE PROOF TEST per TM2050
Test Series DC Recommended Test Voltage Actual Test Voltage
Stator Voltage 18.0 kV DC 45.9 kV DC kV
NOTES 1.) Prior to any high voltage testing, fill in D316218 and get customer agreement on test voltages.
2.) For DC, the test is performed at the end of the DC Leakage Test, use D3162044.
3.) For AC, record results below.
AC HIPOT RESULTS Left (CE) Center (CE) Right (CE) Conditions During HV Proof Test
Passed test at (kV) - 1 min. Winding Temperature (oC)
Failed test at [kV/Time(sec)] Ambient Temperature (oC)
Excitation Voltage (Volts) Relative Humidity (%)
Current (Amps)
Instrument Description ID No. CAL Exp. Date COMMENTS
Megger MIT1025 101343997 08/07/2021

GE Proprietary and Confidential Information. Not to be distributed or reproduced to third parties without prior GE approval
D3162043 Sheet: (a) Rev 2.1 - 08/05/2020

Page 1372 of 1653


GE Power Power Services
Settings
Gap
Sphere
4.5.7
4.5.7 Sphere Gap Settings
FORM
Part Description:
The sphere gap voltmeter is used for calibration checks of the metering system of the Hipot
test equipment and as over-voltage protection for the windings being tested. This equipment
should always be used when performing high voltage tests on generator windings to prevent
applying a potentially destructive voltage to the winding.

Below you can find the settings used for the test performed.

270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 1373 of 1653
d316205 - SPHERE GAP SETTINGS

Sphere Gap Settings


Date 2/24/2021 Generator Serial No. 324 Prepared by: Renan Lopes / Erica Koono
Marina Anders / Marília Oliveira

DC or 0.1 Hz AC (RMS) AC (RMS)


6.25 12.5 6.25
Test Voltage (Kv): 41.4
Temp (C): 24.4
Barometer (in Hg): 29.636
Corrected Voltage (Kv): 41.726
Gap (cm): 1.379
Gap (in): 0.543

Notes:
The DC or 0.1 Hz 6.25 cm settings are good for 10 KV to 88 KV.
The AC (RMS) 12.5 cm settings are good for 10 KV to 65 KV.
The AC (RMS) 6.25 cm settings are good for 10 KV to 62 KV.

Comments:

D316205 Sheet: (a) Rev 0.0 - 12/01/98 GE Energy Proprietary Information

Page 1374 of 1653


GE Power Power Services
Test
leakage
DC
Insulation
Armature
4.5.8
4.5.8 Armature Insulation DC leakage Test
FORM
Part Description:
The leakage current measurement as a function of a DC- high voltage serves for detecting
unusual fault currents and thereby possible weak spots in the insulation.

The leakage current measurement is done in principle phase wise. The leakage current
measurement is carried out directly after the charging current measurement up to a voltage
of 2*UN. The leakage current measurement is done between the winding and the earthed
stator iron core.

With applied DC-voltage to the winding, the currents flowing to earth and through the phases
not staying under voltage are measured. The applied DC- voltage must be gradually
increased according to a precisely defined time program. At every voltage step, after
prescribed times, the corresponding currents are to be measured.

This test was only made on right and left phases, because center phase doesn't present
permissive values for High Voltages Tests. Below you can find the test results.

Recommendation Status: Should be planned for next Outage


Recommendation Description:
The three important elements of a thorough program are maintenance frequency , Visual
Inspection and Electrical testing.
Follow the latest revision of GEK103566 will allow the generator to retain reliability and
avoid major failure expenses.

270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 1375 of 1653
d3162044 - Armature Insulation DC L…

Armature Insulation DC Leakage Test


Date(m/d/y) 2/24/2021 Generator Serial No. 290T818 Prepared by R. Lopes, M. Anders
Customer ENGIE Turbine Serial No. 270T818 M. Oliveira, E. Koono
Manufacture GE FSR No. FSP-221484

A 15 KV DC voltage was applied to each phase with the other two phases grounded for
a period of 10 minutes. Readings were recorded at specific time intervals. On the basis of these readings a
time schedule is established for reading stabilized leakage currents at successively higher voltage values up to
a maximum value, approximately twice line-to-line voltage. The current readings are plotted as a function of
voltage to determine if a nearly linear relationship exists, indicating a constant insulation resistance as a
function of voltage.

Time Left: 15 KV Center: Right: 15KV Winding


(Minutes) µΑ Megohm µΑ Megohm µΑ Megohm Temp (ºC)
0.50 12.00 1300 12.00 1300 35
1.00 9.00 1700 8.60 1700
1.50 5.00 3000 5.90 2500 Wet Bulb (ºF)
2.00 5.70 2600 4.00 3800
3.00 4.40 3400 3.10 4800
3.16 2.80 5400 4.80 3100 Dry Bulb (ºF)
4.00 4.00 3800 3.60 4200
5.00 2.70 5600 2.80 5400
6.00 1.40 11000 3.00 5000 Relative
7.00 1.40 11000 1.80 8300 Humidity
8.00 1.00 15000 1.50 10000 73.8
9.00 1.80 8300 2.00 7500
10.00 2.00 7500 1.40 11000
PI 4.50 6.14
N 61 2

% of Left: 15 KV Center: Right: 15KV


15 KV Time KV µΑ Time KV µΑ Time KV µΑ
100 10' 15 2.00 10' 15 10' 15 1.40
120 14'25" 18 2.10 13'14" 18 13'14" 18 3.30
140 18'17" 21 2.00 15'56" 21 15'56" 21 3.80
160 21'48" 24 2.40 18'17" 24 18'17" 24 4.20
180 25'3" 27 5.80 20'23" 27 20'23" 27 4.30
200 28'5" 30 6.50 22'19" 30 22'19" 30 5.20
220 30'57" 33 6.00 24'4" 33 24'4" 33 10.50
240 33'39" 36 9.80 25'41" 36 25'41" 36 9.20
260 36'13" 39 27'12" 39 27'12" 39
280 38'41" 42 28'37" 42 28'37" 42
300 41'1" 45 29'56" 45 29'56" 45
320 43'17" 48 31'11" 48 31'11" 48
340 45'27" 51 32'23" 51 32'23" 51
360 47'32" 54 33'31" 54 33'31" 54
380 49'33" 57 34'35" 57 34'35" 57
400 51'30" 60 35'36" 60 35'36" 60
420 53'24" 63 36'35" 63 36'35" 63
HIPOT HIPOT HIPOT

D3162044 Sheet: (a) Rev 1.1 - 03/28/13 GE Energy Proprietary Information

Page 1376 of 1653


GE Power Power Services
Test
RTD
4.5.9
4.5.9 RTD Test
FORM
Part Description:
All the RTD’s were tested in the generator terminal box. It was checked resistance in each
RTD and megger with 500Vdc (value tested in prior test). The results were accepted and
nothing inadmissible was detected during the test.

Below you can find the test results

Recommendation Status: Should be planned for next Outage


Recommendation Description:
The three important elements of a thorough program are maintenance frequency , Visual
Inspection and Electrical testing.
Follow the latest revision of GEK103566 will allow the generator to retain reliability and
avoid major failure expenses.

270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 1377 of 1653
d316403 - RTD Test - Dual Element

RTD Test
Dual Element - Copper, Nickel, Platinum or Special
Date 2/25/21 Generator Serial No. 290T818 Prepared By Marília Oliveira
Erica Koono
Turbine Serial No. 270T818 Project ID C-10339092
Test Article Reference: TM2010

Winding Temperature: 34 ºC

Device: Fluke 87 V
Type must be entered as follows: C, N, P or O. *See Note below.
RTD RTD RESISTANCE Indicated Customer
Remarks
No. Type* AB AC BC (AB+AC)/2 - BC Temp. ºC Temp ºC
1 P 114.30 114.30 1.60 112.70 32.99 SLOT 1 - TE
1' P 114.30 114.20 1.60 112.65 32.86 SLOT 1 - TE
2 P 114.80 114.80 1.60 113.20 34.29 SLOT 25 - TE
2' P 114.80 114.80 1.60 113.20 34.29 SLOT 25 - TE
3 P 113.80 113.80 1.40 112.40 32.21 SLOT 49 - TE
3' P 113.80 113.80 1.40 112.40 32.21 SLOT 49 - TE
4 P 113.70 113.70 1.10 112.60 32.73 SLOT 13 - CE
4' P 113.80 113.80 1.10 112.70 32.99 SLOT 13 - CE
5 P 113.60 113.60 0.90 112.70 32.99 SLOT 37 - CE
5' P 113.60 113.60 0.90 112.70 32.99 SLOT 37 - CE
6 P 112.90 112.90 0.80 112.10 31.43 SLOT 61 - CE
6' P 113.00 112.90 0.80 112.15 31.56 SLOT 61 - CE
7
7'
8
8'
9
9'
10
10'
11
11'
12
12'
*RTD Type must be entered as: C, N, P or O O = User Defined RTD Characteristics
Standard RTDs Material Name =
C = Copper 10 Ω @ 25 ºC Reference Resistance RREF = ohms
N = Nickel 120 Ω @ 0 ºC Reference Temperature TREF = ºC
P = Platinum 100 Ω @ 0 ºC (DIN Standard) Coefficient of resistance (α) =
Non-Standard RTDs ohms per ohm /per ºC
O = User defined as described at right RTD Information Source
Megger SN: 101343997 Calibration Date: 6/8/20 Due Date: 7/8/21
Fluke SN: 44840054 Calibration Date: 9/21/20 Due Date: 9/21/21

GE Proprietary and Confidential Information. Not to be distributed or reproduced to third parties without prior GE approval
D316403 Sheet: 1 thru 12 Rev 3.1 - 05/15/2020

Page 1378 of 1653


d316403 - RTD Test - Dual Element

RTD Test
Dual Element - Copper, Nickel, Platinum or Special
Date 2/25/21 Generator Serial No. 290T818 Prepared By Marília Oliveira
Erica Koono
Turbine Serial No. 270T818 Project ID C-10339092

Winding Temperature: 34 ºC
Device: Fluke 87 V
Type must be entered as follows: C, N, P or O. *See Note below.
RTD RTD RESISTANCE Indicated Customer
Remarks
No. Type* AB AC BC (AB+AC)/2 - BC Temp. ºC Temp ºC
13
13'
14
14'
15
15'
16
16'
17
17'
18
18'
19
19'
20 P 115.80 115.80 2.00 113.80 35.84 SLOT 14 - CENTER/TE
20' P 115.80 115.80 2.00 113.80 35.84 SLOT 14 - CENTER/TE
21 P 115.50 115.50 1.90 113.60 35.32 SLOT 38 - CENTER/TE
21' P 115.50 115.50 1.80 113.70 35.58 SLOT 38 - CENTER/TE
22 P 114.90 114.90 1.80 113.10 34.03 SLOT 62 - CENTER/TE
22' P 114.80 114.90 1.90 112.95 33.64 SLOT 62 - CENTER/TE
23
23'
24
24'
*RTD Type must be entered as: C, N, P or O O = User Defined RTD Characteristics
Standard RTDs Material Name =
C = Copper 10 Ω @ 25 ºC Reference Resistance RREF = ohms
N = Nickel 120 Ω @ 0 ºC Reference Temperature TREF = ºC
P = Platinum 100 Ω @ 0 ºC (DIN Standard) Coefficient of resistance (α) =
Non-Standard RTDs ohms per ohm /per ºC
O = User defined as described at right RTD Information Source
Megger SN: 101343997 Calibration Date: 6/8/20 Due Date: 7/8/21
Fluke SN: 44840054.0000 Calibration Date: 9/21/20 Due Date: 9/21/21

GE Proprietary and Confidential Information. Not to be distributed or reproduced to third parties without prior GE approval
D316403 Sheet: 13 thru 24 Rev 3.1 - 05/15/2020

Page 1379 of 1653


d316403 - RTD Test - Dual Element

RTD Test
Dual Element - Copper, Nickel, Platinum or Special
Date 2/25/21 Generator Serial No. 290T818 Prepared By Marília Oliveira
Erica Koono
Turbine Serial No. 270T818 Project ID C-10339092

Winding Temperature: 34 ºC
Device: Fluke 87 V
Type must be entered as follows: C, N, P or O. *See Note below.
RTD RTD RESISTANCE Indicated Customer
Remarks
No. Type* AB AC BC (AB+AC)/2 - BC Temp. ºC Temp ºC
25
25'
26
26'
27
27'
28
28'
29
29'
30
30'
31 P 115.20 115.40 2.10 113.20 34.29 SLOT 2 - CENTER/TE
31' P 115.20 115.20 2.00 113.20 34.29 SLOT 2 - CENTER/TE
32 P 115.90 115.90 2.00 113.90 36.10 SLOT 26 - CENTER/TE
32' P 115.90 115.90 1.90 114.00 36.36 SLOT 26 - CENTER/TE
33 P 115.00 114.90 1.70 113.25 34.42 SLOT 50 - CENTER/TE
33' P 114.80 114.90 1.70 113.15 34.16 SLOT 50 - CENTER/TE
34 P 114.30 114.40 1.30 113.05 33.90 SLOT 3 - CENTER/CE
34' P 114.30 114.30 1.40 112.90 33.51 SLOT 3 - CENTER/CE
35 P 114.10 114.10 1.00 113.10 34.03 SLOT 27 - CENTER/CE
35' P 115.00 115.00 1.30 113.70 35.58 SLOT 27 - CENTER/CE
36 P 115.00 115.00 1.30 113.70 35.58 SLOT 51 - CENTER/CE
36' P 114.10 114.00 1.10 112.95 33.64 SLOT 51 - CENTER/CE
*RTD Type must be entered as: C, N, P or O O = User Defined RTD Characteristics
Standard RTDs Material Name =
C = Copper 10 Ω @ 25 ºC Reference Resistance RREF = ohms
N = Nickel 120 Ω @ 0 ºC Reference Temperature TREF = ºC
P = Platinum 100 Ω @ 0 ºC (DIN Standard) Coefficient of resistance (α) =
Non-Standard RTDs ohms per ohm /per ºC
O = User defined as described at right RTD Information Source
Megger SN: 101343997 Calibration Date: 6/8/20 Due Date: 7/8/21
Fluke SN: 44840054.0000 Calibration Date: 9/21/20 Due Date: 9/21/21

GE Proprietary and Confidential Information. Not to be distributed or reproduced to third parties without prior GE approval
D316403 Sheet: 25 thru 36 Rev 3.1 - 05/15/2020

Page 1380 of 1653


d316403 - RTD Test - Dual Element

RTD Test
Dual Element - Copper, Nickel, Platinum or Special
Date 2/25/21 Generator Serial No. 290T818 Prepared By Marília Oliveira
Erica Koono
Turbine Serial No. 270T818 Project ID C-10339092

RTD INSULATION RESISTANCE TEST RESULTS (MEGOHMS)


RTD INSULATION RESISTANCE (MEGOHMS) @ 500 Volts DC
# 1 thru # 22 = 4920.00 megohms
# 31 thru # 36 = 7900.00 megohms
# thru # = megohms
# thru # = megohms
# thru # = megohms
# thru # = megohms
# thru # = megohms
# thru # = megohms
# thru # = megohms
# thru # = megohms
# thru # = megohms
# thru # = megohms
# thru # = megohms
# thru # = megohms
# thru # = megohms
# thru # = megohms
# thru # = megohms
# thru # = megohms
# thru # = megohms
# thru # = megohms
# thru # = megohms
# thru # = megohms
# thru # = megohms
# thru # = megohms
# thru # = megohms

Megger SN: 101343997 Calibration Date: 6/8/20 Due Date: 7/8/21


Fluke SN: 44840054.0000 Calibration Date: 9/21/20 Due Date: 9/21/21

GE Proprietary and Confidential Information. Not to be distributed or reproduced to third parties without prior GE approval
D316403 Sheet: RTD Megger Rev 3.1 - 05/15/2020

Page 1381 of 1653


GE Power Power Services

4.6 Repairs
Insulation
Damage
Ring
Connection
CATEGORY4.6.1
4.6.1 Connection Ring Damage Insulation
FORM
Part Description:
During the process of selective connection ring block removal, the connection ring (item#81
- T2-LEAD T-1) was damage. A repair using mica tape and Cogebi kit was made.

Below you can find pictures of the repair.

Section of Insulation to be removed Removal of old Insulation

Removal of old Insulation Damage on Connection Ring Bar

270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 1382 of 1653
GE Power Power Services

4.6.1 Connection Ring Damage Insulation


FORM
Damage on Connection Ring Bar Damage filled with Mica/Resin

Connection Ring Section Reinsulated Connection Ring Section Reinsulated

Connection Ring Section Reinsulated Connection Ring Section Reinsulated

270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 1383 of 1653
GE Power Power Services

4.6.1 Connection Ring Damage Insulation


FORM
Application of Teflon and Shrink Tape Application of Teflon and Shrink Tap - Dry
out

Connection Ring new Insulation Connection Ring new Insulation

4.7 Field Visual Inspection

270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 1384 of 1653
GE Power Power Services
Inspection
Visual
As-Found
CATEGORY4.7.1
4.7.1 As-Found Visual Inspection
FORM
Part Condition: Good
Part Description:
RETAINING RINGS

Retaining Rings were visually inspected in the accessible areas for discoloration caused by
arching between the inboard side of the ring and the field end wedges. The rings were also
inspected for signs of pitting, cracks, or mechanical damage; The overall condition of these
were in a satisfactory condition, nonrelevant defects were observed.

FIELD BODY

The field body was visually inspected for relevant oil contamination, rust, mechanical
damage or any sign that could led to an electrical issue. There was no indication of any of
these issues already mentioned.

FIELD WEDGES

The field wedges were inspected for signs of discoloration or burning caused by a negative
sequence/ arching from circulating current either between wedges or between the end
wedges and the retaining rings. No defects were found.

Bore Plugs locked Retaining Ring Locker

270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 1385 of 1653
GE Power Power Services

4.7.1 As-Found Visual Inspection


FORM
Vent Ducts Aligned Collector Ring with Corrosion

Collector Ring Cleaned.


Rings
Retaining
Generator
of
Testing
Current
Eddy
and
Ultrasonic
Automated
4.7.2 Automated Ultrasonic and Eddy Current Testing of
4.7.2
Generator Retaining Rings
FORM
Part Description:
Automated Ultrasonic and Eddy Current Testing of Generator Retaining Rings was made in
order to find any cracks or sings of pitting on the retaining surface.

Below you can find the test results.

Recommendation Status: Should be planned for next Outage


Recommendation Description:
Since there is no indication during retaining ring UT and ET inspection, the retaining ring can
continue service.

270T818
GEGEGE ENGIE ENERGIA PERU SA
CHILCA UNO
Page 1386 of 1653

You might also like