Declaration of conformity

Ozeanic Devices S.L


B055448766
C/Ramón y cajal 9, Ibi (Alicante)

declares that, in accordance with the test certificate for electrical equipment. The product
indicated below, based on its conception and construction, as well as the version marketed on
the market by our company, meets the basic mandatory requirements of the CE directive.

Brand: Ozeanic
Model: Ozone Generator Ecobottle
Certif. Ref. No.: IRTEC200101.00

The product described complies with the following European Directives:

EN 60335-1:2012 + AC:2014 + A11:2014 + A13:2017 + A1:2019


EN 62233:2008 + AC:2008
Harmonized standards under Directive 2014/35/EU – LVD
EN 55014-1:2017
EN 55014-2:2015
SAFEIRTEC200101.00; EMFIIRTEC200101.00; BE2020104.

That the product is made with BPA-free materials and is suitable for use in contact with food
or water.

Below are the results of air flow and ozone concentration generated in measurements carried
out in laboratories on two devices.
Generated air flow (ml/min)
Device A Device B
Measurement 1 975 975
Measurement 2 975 975

The ozone concentration generated by each System is indicated below:


Concentra�on in generated water (mg 0 3/min)

1 minute 0,17±0,07 Sample Nº: A/0006103/21


3 minute 0,19±0,07 Sample Nº: A/0006104/21
5 minute 0,33±0,07 Sample Nº: A/0006105/21

SANITARY PROYECTOS Y OBRAS S.L.


ESSAY REPORT
Sample Nº: A/0006103/21
Sample Nº: A/0006104/21
Sample Nº: A/0006105/21
V.03 ___ pág.1
Declaration of conformity

Study of ozone concentration in water after generating ozone.

Device A (with diffuser): 5 consecu�ve treatments. Open bo�le.


Water sampling a�er every minute of treatment.

Sample Descrip�on Concentra�on mg/l O3


1- A�er the first minute < 0,03
2- A�er second minute < 0,03
3- A�er third minute < 0,03
4- A�er fourth minute < 0,03
5- A�er fi�h minute < 0,03
Ozone concentra�on in 0.5L of water < 0,03

Device B Ozone concentra�on in water mg/l 03

Sample Descrip�on Concentra�on mg/l O3


1- A�er the first minute With diffuser < 0,03
Without diffuser < 0,03
3- A�er third minute With diffuser < 0,03
Without diffuser < 0,03

It is concluded that there is no risk of high concentration of ozone in the water and it is suitable for
drinking without ozone toxicity traces.

SANITARY PROYECTOS Y OBRAS S.L.


ESSAY REPORT

Sample Nº: A/0005589/21

V.03 ___ pág.2


Declaration of conformity
Tests carried out by
SANITARY PROYECTOS Y OBRAS S.L.

Evaluation of the bactericidal activity of ozonated water.

The standard UNE-EN 1276: 2010 and Erratum 2011: Antiseptics and chemical disinfectants
are taken as a reference. Quantitative suspension test for activity evaluation
bactericide of antiseptics and chemical disinfectants used in food products, in industry, in the
home and in the community. (Test method and requirements - phase 2, step 1)

Inocula�on of 500Mml of water with Escherichia coli ß glucoronidase posi�ve


Inactivation test verification of the E.coli strain (CECT 516) in 500 ml of water carried out after
applying a 3-minute treatment with OZONE and waiting another 5 minutes before carrying out
the microbiological test.
The water was contaminated to concentration of 1.0E2 Cfu/ml obtaining a total inactivation
after the treatment (reduction of 2 log) (total inactivation 99%)

SANITARY PROYECTOS Y OBRAS S.L.


ESSAY REPORT
Sample Nº: A/0005471/21

Inocula�on of 500Mml of water with Enterococcus faecalis (CECT 481)


Inactivation test verification of the Enterococcus faecalis (CECT 481) in 500 ml of water carried
out after applying a 3-minute treatment with OZONE and waiting another 5 minutes before
carrying out the microbiological test.
The water was contaminated to concentration of 1.0E2 Cfu/ml obtaining a total inactivation
after the treatment (reduction of 2 log) (total inactivation 99%)

SANITARY PROYECTOS Y OBRAS S.L.


ESSAY REPORT
Sample No.: A/0006117/21

V.03 ___ pág.3


Declaration of conformity
Tests carried out by
AINIA CENTRO TECNOLÓGICO

The reference strains used in the assay, has been one of the two detailed bacteria
in the norm UNE-EN 1276:
o Pseudomonas aeruginosa ATCC 15442
o Staphylococcus aureus ATCC 6538

Inocula�on of 500Mml of water with Pseudomonas aeruginosa ATCC 15442


Inactivation test verification of the Pseudomonas aeruginosa in 500 ml of water carried out after
applying a 1-minute treatment with OZONE and waiting another 1 minutes before carrying out
the microbiological test.
The water was contaminated to concentration of 10E4-10E5 ufc/ml obtaining a total
inactivation after the treatment (reduction of 2 log) (total inactivation 99%)

AINIA CENTRO TECNOLÓGICO


REPORT
Sample Nº: SIG:21-P00038 \ 22-06-2021

Inocula�on of 500Mml of water with Staphylococcus aureus ATCC 6538


Inactivation test verification of the Staphylococcus aureus in 500 ml of water carried out after
applying a 1-minute treatment with OZONE and waiting another 1 minutes before carrying out
the microbiological test.
The water was contaminated to concentration of 10E4-10E5 ufc/ml obtaining a total
inactivation after the treatment (reduction of 2 log) (total inactivation 99%)

AINIA CENTRO TECNOLÓGICO


ESSAY REPORT
Sample Nº: SIG:21-P00038 \ 22-06-2021

After the ozonation treatment in the two types of samples, the level of bacterial reduction and
the disinfectant activity of the device were calculated.

V.03 ___ pág.4


1) E.coli strain (CECT 516)
Symptoms and clinical manifestations
Escherichia coli (also known as E. coli) is an example of a bacterium that is present in large quantities
in our normal human and animal gut microbiota, where it is generally not harmful. However, in other
parts of the body, E. coli can cause nausea, vomiting, abdominal pain, and diarrhea, with severe
clinical conditions such as urinary tract infections, bacteremia, and meningitis.

Symptoms usually appear between one and eight days.

Source of contamination
Transmission of pathogenic E. coli through water has been proven in recreational waters and contami-
nated drinking water. For example, the drinking water supply may be contaminated because rainwater
containing livestock excrement has leaked out.

2) EP.aeruginosa (CECT 108)


Symptoms and clinical manifestations
Pseudomonas aeruginosa can cause many types of infections, but it rarely causes serious illness in
people without risk factors, such as cystic fibrosis or immunosuppressed patients. The bacteria predo-
minantly colonize damaged sites such as burns and surgical wounds, the respiratory tract of people
with underlying illnesses, and physically damaged eyes. From these locations, the infection can spread
throughout the body, causing destructive lesions or septicemia and meningitis. Mild manifestations
include folliculitis and water-related ear infections after exposure to hot and humid environments such
as pools and spas.

Source of contamination
P. aeruginosa is a common environmental microorganism and can be found in feces, soil, and water,
especially wastewater. Like Legionella it can multiply in aquatic environments and also on the surface
of certain organic materials in contact with water. It has been insulated from a variety of humid environ-
ments such as sinks, water baths, hot water systems, showers, and spa pools. Ingestion of drinking
water is not a major source of infection, although it can be associated with changes in taste, odor, and
cloudiness.

3) Enterococcus faecalis (CECT 481)


Enterococcus faecalis and E. faecium cause a variety of infections, including endocarditis, urinary and
intra-abdominal infections, prostatitis, cellulitis, and wound infections, as well as concurrent bactere-
mia. Enterococci are part of the normal intestinal flora.

Symptoms, fever, chills and body aches.


Weakness or dizziness. Urinating more often than usual or painful urination. Urine that smells bad, or
blood in the urine.
Pain or cramps in the abdomen.

V.03 ___ pág.5


Declaration of conformity

Bottles used in the tests.


AINIA technology Center
and
SANITARY PROYECTOS Y OBRAS S.L

Spain, 21-6-2021

Jose Ramón Campos


Manager

V.03 ___ pág.6


SANITARY PROYECTOS Y OBRAS S.L.
TEST REPORT

Sample Nº: A/0006103/21

Customer identification
Legal name OZEANIC-DEVICES S.L Addres
Trade name C/ Ramón y Cajal, nº 9 - Puerta 3
Phone 659595774
Fax ALICANTE 3440

Sample identification
Final customer
Date sample colletion 03/06/2021

Type of sample WATERS FOR HUMAN CONSUMPTION Reception date 03/06/2021


Reference sample Start analysis date 04/06/2021
Container Final analysis date 04/06/2021
Date emission analysis 04/06/2021

Conserv. laboratory mode


Information provided by the client:
1 MINUTE OZONE TREATMENT (WITH BLUE STONE)
Determinations Results Units Maximum concentration Metodology P.N.T.

Ozono 0,17±0,07 mg/l Espectrofotometria

Maximum concentration referred to Royal Decree 140/2003, of February 7, which establishes the sanitary criteria for the quality of water for human
consumption

Dirección Técnica
María Teresa Valverde Franco
Lda. en Biología

The results that are preceded by the expression "<" correspond to the limit of quantification / detection of the method.
The uncertainties of the tests are calculated and available to the client.
The results of this report correspond only to the objects under test.
The total or partial re-production of this report is prohibited without the express authorization of SANITARY PROYECTOS Y OBRAS, S.L.
SANITARY PROYECTOS Y OBRAS, S.L. It is not responsible for the information provided by the client for the description of the sample. The
results are applied to the sample as received.

SANITARY PROYECTOS Y OBRAS S.L.. - CIF: B-73082737 C/ VILLANUEVA DEL SEGURA S/N 30500 MOLINA DE SEGURA - MURCIA. Page 1 of 1
Tlno./Fax 968643579 638629387 968643579 E.Mail laboratorio@sanitary.es / calidad@sanitary.es web www.sanitary.es
PGE-13-01/07
SANITARY PROYECTOS Y OBRAS S.L.
TEST REPORT

Sample Nº: A/0006104/21

Customer identification
Legal name OZEANIC-DEVICES S.L Addres
Trade name C/ Ramón y Cajal, nº 9 - Puerta 3
Phone 659595774
Fax ALICANTE 3440

Sample identification
Final customer
Date sample colletion 03/06/2021

Type of sample WATERS FOR HUMAN CONSUMPTION Reception date 03/06/2021


Reference sample Start analysis date 04/06/2021
Container Final analysis date 04/06/2021
Date emission analysis 04/06/2021

Conserv. laboratory mode


Information provided by the client:
3 MINUTE OZONE TREATMENT (WITH BLUE STONE)
Determinations Results Units Maximum concentration Metodology P.N.T.

Ozono 0,19±0,07 mg/l Espectrofotometria

Maximum concentration referred to Royal Decree 140/2003, of February 7, which establishes the sanitary criteria for the quality of water for human
consumption

Dirección Técnica
María Teresa Valverde Franco
Lda. en Biología

The results that are preceded by the expression "<" correspond to the limit of quantification / detection of the method.
The uncertainties of the tests are calculated and available to the client.
The results of this report correspond only to the objects under test.
The total or partial re-production of this report is prohibited without the express authorization of SANITARY PROYECTOS Y OBRAS, S.L.
SANITARY PROYECTOS Y OBRAS, S.L. It is not responsible for the information provided by the client for the description of the sample. The
results are applied to the sample as received.

SANITARY PROYECTOS Y OBRAS S.L.. - CIF: B-73082737 C/ VILLANUEVA DEL SEGURA S/N 30500 MOLINA DE SEGURA - MURCIA. Page 1 of 1
Tlno./Fax 968643579 638629387 968643579 E.Mail laboratorio@sanitary.es / calidad@sanitary.es web www.sanitary.es
PGE-13-01/07
SANITARY PROYECTOS Y OBRAS S.L.
TEST REPORT

Sample Nº: A/0006105/21

Customer identification
Legal name OZEANIC-DEVICES S.L Addres
Trade name C/ Ramón y Cajal, nº 9 - Puerta 3
Phone 659595774
Fax ALICANTE 3440

Sample identification
Final customer
Date sample colletion 03/06/2021

Type of sample WATERS FOR HUMAN CONSUMPTION Reception date 03/06/2021


Reference sample Start analysis date 04/06/2021
Container Final analysis date 04/06/2021
Date emission analysis 04/06/2021

Conserv. laboratory mode


Information provided by the client:
5 MINUTE OZONE TREATMENT (WITH BLUE STONE)
Determinations Results Units Maximum concentration Metodology P.N.T.

Ozono 0,33±0,07 mg/l Espectrofotometria

Maximum concentration referred to Royal Decree 140/2003, of February 7, which establishes the sanitary criteria for the quality of water for human
consumption

Dirección Técnica
María Teresa Valverde Franco
Lda. en Biología

The results that are preceded by the expression "<" correspond to the limit of quantification / detection of the method.
The uncertainties of the tests are calculated and available to the client.
The results of this report correspond only to the objects under test.
The total or partial re-production of this report is prohibited without the express authorization of SANITARY PROYECTOS Y OBRAS, S.L.
SANITARY PROYECTOS Y OBRAS, S.L. It is not responsible for the information provided by the client for the description of the sample. The
results are applied to the sample as received.

SANITARY PROYECTOS Y OBRAS S.L.. - CIF: B-73082737 C/ VILLANUEVA DEL SEGURA S/N 30500 MOLINA DE SEGURA - MURCIA. Page 1 of 1
Tlno./Fax 968643579 638629387 968643579 E.Mail laboratorio@sanitary.es / calidad@sanitary.es web www.sanitary.es
PGE-13-01/07
SANITARY PROYECTOS Y OBRAS S.L.
TEST REPORT

Sample Nº: A/0005589/21

Customer identification
Legal name OZEANIC-DEVICES S.L Addres
Trade name C/ Ramón y Cajal, nº 9 - Puerta 3
Phone 659595774
Fax ALICANTE 3440

Sample identification
Final customer
Date sample colletion 25/05/2021

Type of sample WATERS FOR HUMAN CONSUMPTION Reception date 25/05/2021


Reference sample Start analysis date 25/05/2021
Container Final analysis date 26/05/2021
Date emission analysis 26/05/2021

Conserv. laboratory mode


Information provided by the client:
OZONE TREATMENT 1 MINUTE, (MEASURED AFTER 1 MINUTE OF TREATMENT)
Determinations Results Units Maximum concentration Metodology P.N.T.

Ozono 0,03 mg/l Espectrofotometria

Maximum concentration referred to Royal Decree 140/2003, of February 7, which establishes the sanitary criteria for the quality of water for human
consumption

Dirección Técnica
María Teresa Valverde Franco
Lda. en Biología

The results that are preceded by the expression "<" correspond to the limit of quantification / detection of the method.
The uncertainties of the tests are calculated and available to the client.
The results of this report correspond only to the objects under test.
The total or partial re-production of this report is prohibited without the express authorization of SANITARY PROYECTOS Y OBRAS, S.L.
SANITARY PROYECTOS Y OBRAS, S.L. It is not responsible for the information provided by the client for the description of the sample. The
results are applied to the sample as received.

SANITARY PROYECTOS Y OBRAS S.L.. - CIF: B-73082737 C/ VILLANUEVA DEL SEGURA S/N 30500 MOLINA DE SEGURA - MURCIA. Page 1 of 1
Tlno./Fax 968643579 638629387 968643579 E.Mail laboratorio@sanitary.es / calidad@sanitary.es web www.sanitary.es
PGE-13-01/07
SANITARY PROYECTOS Y OBRAS S.L.
SANITARY PROYECTOS Y
TEST REPORT TEST REPORT

Sample Nº: A/0006117/21 Sample Nº: A/0006117/2

Customer identification Customer identification


Legal name OZEANIC-DEVICES S.L OZEANIC-DEVICES S.L
Legal name Addres Addres
Trade name Trade name C/ Ramón y Cajal, nº 9 - Puerta 3 C/ Ram
Phone 659595774 Phone 659595774
Fax Fax ALICANTE 3440 ALICA

Sample identification Sample identification


Final customer Final customer
Date sample colletion 03/06/2021

Type of sample WATERS FOR HUMAN CONSUMPTION Type of sample Reception


WATERS date
FOR HUMAN 03/06/2021
CONSUMPTION
Reference sample Reference sample Start analysis date 03/06/2021
Container ORIGINAL CONTAINER Container ORIGINAL CONTAINER
Final analysis date 03/06/2021
Date emission analysis 04/06/2021

Conserv. laboratory mode REFRIGERATED Conserv. laboratory mode REFRIGERATED


Information provided by the client: Information provided by the client:
500 ML OF WATER PREVIOUSLY CONTAMINATED WITH ENTEROCOCUS.
500 ML3OF MINUTE
WATER PREVIOUSLY CONTAMINATED WITH ENTEROCOCUS. 3 MINUTE
TREATMENT WITH OZONE APPLIED AND WITH BLUE STONE. ANALYSIS
TREATMENTPERFORMED
WITH OZONE APPLIED AND WITH BLUE STONE. ANALYSIS PERFORME
AFTER 5 MINUTES OF REST. AFTER 5 MINUTES OF REST.
Determinations Results Units
Determinations Maximum concentration Metodology
Results P.N.T.
Units M
Enterococos totales - 2 log ufc/ml totales
Enterococos - 2 log
Count ufc/ml
Maximum concentration referred to Royal Decree 140/2003, of February 7, whichconcentration
Maximum establishes the sanitary
referred to criteria for the quality
Royal Decree of water
140/2003, for human
of February 7, which esta
consumption consumption

Discussion about the Essay/Results Discussion about the Essay/Results


The analysis carried out was an inactivation verification test of the Enterococcus
The analysisfaecalis strain
carried out (CECT
was an 481) in 500 ml
inactivation of water after
verification test ofapplying a
the Enterococcus faec
3-minute treatment with OZONE and wait another 5 minutes before carrying out treatment
3-minute the microbiological
with OZONEtest.and
Thewait
water was contaminated
another 5 minutes beforewith carrying
strain out the m
to a concentration of 1.0E2 Ufc / ml, obtaining a total inactivation after the
to atreatment of a 2oflog
concentration reduction
1.0E2 (total
Ufc / ml, inactivation
obtaining 99%)
a total inactivation after the treatment o

Dirección Técnica
María Teresa Valverde Franco
Lda. en Biología

The results that are preceded by the expression "<" correspond to the limit The of quantification
results / detectionbyofthe
that are preceded theexpression
method. "<" correspond to the limit of quantific
The uncertainties of the tests are calculated and available to the client. The uncertainties of the tests are calculated and available to the client.
The results of this report correspond only to the objects under test. The results of this report correspond only to the objects under test.
The total or partial re-production of this report is prohibited without the express
The totalauthorization of SANITARY
or partial re-production PROYECTOS
of this Y OBRAS,
report is prohibited S.L. the express author
without
SANITARY PROYECTOS Y OBRAS, S.L. It is not responsible for the information SANITARYprovided
PROYECTOS by the Yclient for the
OBRAS, description
S.L. of the sample.
It is not responsible Theinformation prov
for the
results are applied to the sample as received. results are applied to the sample as received.

SANITARY PROYECTOS Y OBRAS S.L.. - CIF: B-73082737 C/ VILLANUEVA DEL SEGURA


SANITARY S/N 30500 MOLINA
PROYECTOS Y OBRASDES.L..
SEGURA - MURCIA. C/ VILLANUEVA
- CIF: B-73082737 Page 1 ofDEL
1 SEGUR
Tlno./Fax 968643579 638629387 968643579 E.Mail laboratorio@sanitary.es / calidad@sanitary.es web638629387
Tlno./Fax 968643579 www.sanitary.es
968643579 E.Mail laboratorio@sanitary.es / calid
PGE-13-01/07
BRAS S.L.

y Cajal, nº 9 - Puerta 3

3440

Date sample colletion 03/06/2021


Reception date 03/06/2021
Start analysis date 03/06/2021
Final analysis date 03/06/2021
Date emission analysis 04/06/2021

um concentration Metodology P.N.T.


Count

es the sanitary criteria for the quality of water for human

train (CECT 481) in 500 ml of water after applying a


iological test. The water was contaminated with strain
log reduction (total inactivation 99%)

Dirección Técnica
María Teresa Valverde Franco
Lda. en Biología

/ detection of the method.

n of SANITARY PROYECTOS Y OBRAS, S.L.


by the client for the description of the sample. The

30500 MOLINA DE SEGURA - MURCIA. Page 1 of 1


anitary.es web www.sanitary.es
PGE-13-01/07
The following tables show the microbial reduction results obtained after the
exposure time of the microorganism with ozonated water:

Sample Nº: SIG:21-P00038 \ 22-06-2021


Pseudomonas aeruginosa
Recuento Recuento
Tratamiento Recuento Recuento Reducción Reducción
tras t tras t
(número de inicial inicial bacteriana bacteriana
exposición exposición
pulsaciones) (ufc/ml) (log 10 ) (log 10 ) (%)
(ufc/ml) (log 10 )
0 2,1 x 10 4
4,32
1 2,1 x 10 4
4,32 2,0 x 10 2
2,30 2,02 99,048%
5 2,1 x 10 4
4,32 1,0 x 10 2
2,00 2,32 99,524%
10 2,1 x 10 4
4,32 <1,0 x 10 0
0,00 4,32 99,995%

Staphylococcus aureus
Recuento Recuento
Tratamiento Recuento Recuento Reducción Reducción
tras t tras t
(número de inicial inicial bacteriana bacteriana
exposición exposición
pulsaciones) (ufc/ml) (log 10 ) (log 10 ) (%)
(ufc/ml) (log 10 )
0 9,0 x 10 4
4,95
1 9,0 x 10 4
4,95 <1,0 x 10 0
0,00 4,95 99,999%
5 9,0 x 10 4
4,95 <1,0 x 10 0
0,00 4,95 99,999%
10 9,0 x 10 4
4,95 <1,0 x 10 0
0,00 4,95 99,999%

Escherichia coli
Recuento Recuento
Tratamiento Recuento Recuento Reducción Reducción
tras t tras t
(número de inicial inicial bacteriana bacteriana
exposición exposición
pulsaciones) (ufc/ml) (log 10 ) (log 10 ) (%)
(ufc/ml) (log 10 )
0 1,9 x 10 5
5,28
1 1,9 x 10 5
5,28 4,8 x 10 4
4,68 0,60 74,737%
5 1,9 x 10 5
5,28 5,0 x 10 0
0,70 4,58 99,997%
10 1,9 x 10 5
5,28 3,0 x 10 0
0,48 4,80 99,998%
Nota: <1,0 x 10 0
ufc/ml= límite de detección de la técnica
Test Certificate No.:

IRTEC200101.00

Nombre y dirección del OZEANIC DEVICES, S.L.


solicitante: C/ Ramón y Cajal, 9-3
Name and address of the applicant: 03440 Ibi - Alicante
(España/Spain)
CERTIFICADO DE ENSAYOS / TEST CERTIFICATE

Producto: Generador de ozono


Product: Ozone generator

Marca: OZEANIC
Trademark:

Modelo(s) / Ref. de tipo: Ver página 2


Model(s) / Type ref.: See page 2

Valores y características Ver página 2


principales: See page 2
Ratings and principal
characteristics:

La/s muestra/s del producto EN 60335-1:2012 + AC:2014 + A11:2014 + A13:2017 +


se ha/n ensayado y se A1:2019
considera/n conforme/s con: EN 62233:2008 + AC:2008
The sample/s of the product Harmonized standards under Directive 2014/35/EU – LVD
was/were tested and found to be in
conformity with Tested according to:
EN 55014-1:2017
EN 55014-2:2015

Como se muestra en el SAFEIRTEC200101.00; EMFIIRTEC200101.00;


Informe de Ensayo Ref. No.: BE2020104.
As shown in the Test Report Ref. No.

Fecha/Date: 11/06/2021 Firma/Signature:

David Latorre
(Documento firmado mediante firma electrónica)
Página/Page: 1 de/of 2 (Document signed by means of electronic signature)

IMQ TECNOCREA S.L.


C/ Sèquia de Benàger, 23. Pol. Ind. Alquería de Moret. 46210. Picanya Valencia – España (Spain).
Test Certificate No.:

IRTEC200101.00

Detalles modelos*:
Model details*:

Valores y características principales:


CERTIFICADO DE ENSAYOS / TEST CERTIFICATE

Ratings and principal characteristics

5Vcc. 250mA. Batería 3,7V 420mAh.


5Vdc. 250mA. Battery 3,7V 420mAh.

Modelo/Ref. de tipo:
Model/Type ref:

OZONE GENRATOR N1

* Este certificado de ensayo se refiere solo a la(s) muestra(s) particular(es) sometida(s) a ensayo y a las secciones ensayadas tal
y como se recoge en los citados informes de ensayo. / * This test certificate refers only to the particular sample(s)PEG-13-01/04
submitted for
testing and sections tested as stated in the mentioned test reports.

Fecha/Date: 11/06/2021 Firma/Signature:

David Latorre
(Documento firmado mediante firma electrónica)
Página/Page: 2 de/of 2 (Document signed by means of electronic signature)