LED FLASHER RELAYS Bussmann

LED FLASHERS: The new Bussmann series LED flashers should always be used with
LED turn signals because they require less current. Using traditional thermal/mechanical
flashers for LEDs will cause erratic operation by flashing too fast or too slow.

Part Number Terminals Electrical Rating Nbr. Bulbs


NO-727-LED 6.3mm (0.25") x 5 12.6A at 12.8VDC 2 to 4
NO-758-LED 6.3mm (0.25") x 3 12.6A at 12.8VDC 2 to 6
NO-759-LED 6.3mm (0.25") x 3 12.6A at 12.8VDC 2 to 6
NO-760-LED 6.3mm (0.25") x 3 12.6A at 12.8VDC 2 to 4
NO-762-LED 2.8mm x 4 12.6A at 12.8VDC 2 to 6

L (-)
E
H
NO-727-LED NO-759-LED NO-762-LED
Terminal + (-) Terminal Terminal
I B + S L
Layout L Layout Layout

NO-758-LED NO-760-LED
(-) +
Terminal + (-) Terminal
L Layout L Layout

Please refer to the following pages for detailed specifications of each relay.

RELATED PRODUCTS:

Scan this
QR Code
for more
information

QR Code: 9029

Hazard Lights Switch


Suits 3 & 4 terminal flashers

Email: info@prolecproducts.com
Datasheet: 9023 Web: www.prolecproducts.com Page: 1
LED FLASHER RELAYS (cont'd.) Bussmann

NO-727-LED
Heavy Duty Electronic LED Flasher
Number Lamps: 2 to 4 E
L
Terminal
Number Terminals: 5 H
Layout
Terminal Size: 6.35mm (1/4") I B

Specifications: FMVSS108, SAE J590B, J945 & J1690 Class A


Rated Load: Fixed load 2 lamps for turn signal /
4 lamps for hazard warning
SAE number 1156 lamps.
Lamp Ratings: No.1156, 2.1A at12.8V
No.1895, 0.27A at 14V
1-12 Amps
Power: 162W
Temperature Rating: - 32 °C to + 60 °C
Rated Voltage: 11 to 15V, 11 to 13V (53 °C )
Voltage Drop at Current: 800mV
Time to First Flash: Less than 1.5 secs
Flash Rate over Temp. Range: 60 to 120 flashes/minute
Duty Cycle: 35% to 75%
Electrical Source: 15A & 10A fused circuits

42.5

6.3

Dimensions in MM
8.7

8.7
Symbols:
B = Battery (power input)
E = Ground
Turn Signal & Hazard Light I = Ignition
H = Hazard Switch
Circuit Diagram
L = Load

30.5

Email: info@prolecproducts.com
Datasheet: 9023 Web: www.prolecproducts.com Page: 2
LED FLASHER RELAYS (cont'd.) Bussmann

NO-758-LED
Heavy Duty Electronic LED Flasher
Number Lamps: 2 to 6 Terminal
Number Terminals: 3 (-) +
Layout
Terminal Size: 6.35mm (1/4") L

Specifications: FMVSS108, SAE J590B, J945 & J1690 Class A


Rated Load: Fixed load 2 to 6 SAE number 1156 lamps.
Lamp Ratings: No.1156, 2.1A at12.8V
No.1895, 0.27A at 14V
1-12 Amps
Power: 162W
Temperature Rating: - 23 °C to + 60 °C
Rated Voltage: 11 to 15V, 11 to 13V (53 °C ),
12.8V (25 °C ), 11 to 13V (-17 °C )
Voltage Drop at Current: 800mV
Time to First Flash: Less than 1.5 secs
Flash Rate over Temp. Range: 60 to 120 flashes/minute
Duty Cycle: 35% to 75%
Electrical Source: 15A & 10A fused circuits

24.9

53.1
Hazard SW

6.3

8.7

Turn Signal & Hazard Light


Circuit Diagram Symbols: 8.7
L = Lamp Load
B = Electrical Source (+) 26.4 8.7
E = Ground (-)

Dimensions in MM

Email: info@prolecproducts.com
Datasheet: 9023 Web: www.prolecproducts.com Page: 3
LED FLASHER RELAYS (cont'd.) Bussmann

NO-759-LED
Heavy Duty Electronic LED Flasher
Number Lamps: 2 to 6 Terminal
Number Terminals: 3 + (-) Layout
Terminal Size: 6.35mm (1/4") L

Specifications: FMVSS108, SAE J590B, J945 & J1690 Class A


Rated Load: Fixed load 2 to 6 SAE number 1156 lamps.
Lamp Ratings: No.1156, 2.1A at12.8V
No.1895, 0.27A at 14V
1-12 Amps
Power: 162W
Temperature Rating: - 23 °C to + 60 °C
Rated Voltage: 11 to 15V, 11 to 13V (53 °C ),
12.8V (25 °C ), 11 to 13V (-17 °C )
Voltage Drop at Current: 800mV
Time to First Flash: Less than 1.5 secs
Flash Rate over Temp. Range: 60 to 120 flashes/minute
Duty Cycle: 35% to 75%
Electrical Source: 15A & 10A fused circuits

24.9
14.2 4.8

47.0
Hazard SW

8.7 8.7
6.3

Dimensions in MM
8.7
Turn Signal & Hazard Light
Circuit Diagram Symbols:
L49a = Lamp Load
26.4 49(+) = Electrical Source
31(-) = Ground

Email: info@prolecproducts.com
Datasheet: 9023 Web: www.prolecproducts.com Page: 4
LED FLASHER RELAYS (cont'd.) Bussmann

NO-760-LED
Heavy Duty Electronic LED Flasher
Number Lamps: 2 to 4 Terminal
Number Terminals: 3 + (-) Layout
Terminal Size: 6.35mm (1/4") L

Specifications: FMVSS108, SAE J590B, J945 & J1690 Class A


Rated Load: Fixed load 2 to 4 SAE number 1156 lamps.
Lamp Ratings: No.1156, 2.1A at12.8V
No.1895, 0.27A at 14V
1-12 Amps
Power: 162W
Temperature Rating: - 23 °C to + 60 °C
Rated Voltage: 11 to 15V, 11 to 13V (53 °C ),
12.8V (25 °C ), 11 to 13V (-17 °C )
Voltage Drop at Current: 800mV
Time to First Flash: Less than 1.5 secs
Flash Rate over Temp. Range: 60 to 120 flashes/minute
Duty Cycle: 35% to 75%
Electrical Source: 15A & 10A fused circuits

Dimensions in MM

Turn Signal & Hazard Light


Circuit Diagram Symbols:
L49a = Lamp Load
49(+) = Electrical Source
31(-) = Ground

Email: info@prolecproducts.com
Datasheet: 9023 Web: www.prolecproducts.com Page: 5
LED FLASHER RELAYS (cont'd.) Bussmann

NO-762-LED
Heavy Duty Electronic LED Flasher
Number Lamps: 3 to 6 (-)
Terminal
Number Terminals: 4 Layout
Terminal Size: 2.8mm (ISO 280) + S L

Specifications: FMVSS108, SAE J590B, J945 & J1690 Class A


Rated Load: Fixed load 3 to 6 SAE number 1156 lamps.
Lamp Ratings: No.1156, 2.1A at12.8V
No.1895, 0.27A at 14V
1-12 Amps
Power: 162W
Temperature Rating: - 23 °C to + 60 °C
Rated Voltage: 11 to 15V, 11 to 13V (53 °C ),
12.8V (25 °C ), 11 to 13V (-17 °C )
Voltage Drop at Current: 800mV
Time to First Flash: Less than 1.5 secs
Flash Rate over Temp. Range: 60 to 120 flashes/minute
Duty Cycle: 35% to 75%
Electrical Source: 15A & 10A fused circuits

24.9
7.5A FUSE
- 4.8
+ S L
14.2

47.0
Hazard SW

15A FUSE
LEFT RIGHT

8.1
26.4
12V
BATTERY

3W 3W 2.3
7.8
PILOT LED LED LED LED LED LED PILOT
Symbols:
L = Lamp Load
(+) = Electrical Source
Turn Signal & Hazard Light (-) = Ground
Circuit Diagram 16.2 S = Sense

Dimensions in MM

Email: info@prolecproducts.com
Datasheet: 9023 Web: www.prolecproducts.com Page: 6