Width X Depth X Height
12 0X855X19 0 2280X855X1900 2835X1000X1950 3955X1090X1950
(mm)
*conditions apply
If you need any further information about SORO UPS, please give us your message(s) by the following information given, we can reply you as quickly as possible.
GP9335C 120-800kVA
Loaded With Features
We have studled the emerging needs of our customers and have engineered what we have leared
into the new,upgraded Low frequency UPS GP9335 Series.Now it offers you more value and power
per square meter. You willfind that The Low frequency UPS GP9335 Series offers unique featuers
that address the needs of your businesstoday and is designes to handle the needs that are expected
Addressing A Variety in future.
Of Needs
The Low frequency UPS GP9335 Features To Protect Your Network
Series reliable,scalable and user- Fully Digital, twin DSP controlled. Network protocols SNMP.
friendly solution to ensure availability Handle Leading power factor loads without Overload capability of the UPS:
of networks.The Low frequency UPS KW de-rating under specified conditions - 110% full-load for 60 minutes
GP9335 Series offers protection to - 125% full-load for 10 minutes
On-Line Double Conversion - 150% full-load for 1 minute
your invesment and lower costof
IGBT-based PWM Inverter Easy Scalability (Parallel 1+N configurationup
ownership through its digital
Wide input voltage tolerance (+15 / -15%) to 6 modules paralleling) without centralised
architectureand range of options
Wide input frequency tolerance (45Hz-65Hz) Main Static Switch (MSS)
which you can customize
specifically foryour needs. High overload capability of static bypass Bypass Switch
(14 times for 10 milliseconds and 10 times Compact footprint
for 100 milliseconds)
Built In Investment Protection
Capability to handle:
Temperature-compensated battery charging
- High crest factor loads (optional)
- 100% non-linear loads Automatic battery testing
Information Technology Banking, Insurance and Financial Services
- 100% unbalanced loads
- Cem filters Field settability of end-cell voltage of the battery
Software Development Houses Built-in maintenance bypass (Single and 1+N
- Accordance with IEC EN 62040-3 Selectable timer for boost charging duration of
/ Software Technology Parks (STP) Models)
- Security and electro-medical the battery (15 steps with each step of 1 hour)
Building Automation Wrap-around maintenance bypass (optional)
Protection against deep discharge of battery
- Access Control Front access for spares replacement and
Telecommunication Battery circuit breaker instead of using AC isolator
- Security System preventive maintenance
- Mobile (2G, 2.5G, 3G) Short-circuit proof inverter
- Fire Alarm System Easy Dual bus configuration architecture
- Paging - Emergency Lighting Back-feed protection
Provision to use any type of battery: Wet cells
- Fixed (including WLL) - Other Critical Applications D-level lightning protection
(Tubular Plant ), Valve Regulated Lead Acid
Industrial Automation Medical Diagnostics (VRLA) /Maintenance Free and Nickel Cadmium With 3 auxilliary power supply to ensure
- Process (including instrumentation) - Magneto Resonant Imaging redundanc under any conditiony
Adjustable frequency synchronisation window
- Motion (digital drives and robotics) - CT Scanning Standard dry contacts
up to9% in the static bypass
Transport Automation - CathLab Provision of automatic battery circuit breaker Choice between 6 or 12-pulse rectifier
- Airport automation and flight booking Satellite instead of using conventional isolator in the Choice of array of input harmonic filter options.
- Others including railways and road - Uplinking DC path Compatible with SOROTEC AF, the active
transport automation and ticket booking - Earth Stations Field protocols ModBus / Jbus harmonc filter.
GP9335C 300-800kVA UPS PHOTO
A LCD Display
B Air Filter A
C Electronic control PCB
D N+X assistant power
supply PCB
E Battery monitor
connect terminal C
F 220V Socket B
G
Input power switch D
E
G
H
I J
Easy installation
layered freestanding
obturator-ventilation
Installated against the wall
the favourable ventilation
design
can pass in and out
the cables from the top
GP9335 can be scaled up to as high as 6 modules using any of the following - Feed one (Priority) or two (Priority
configurations to achieve eitherscalability or redundancy of desired percentage. and Normal) load banks depending
on the application need Bypass Mains
1+N Configuration with Distributed bypass System installation regardless of the UPS size,
the generation of (device or technology
- Up to six modules in parallel or philosophy of control) and the
manufacturer
- Increase the system reliability
- Increase the availability of quality power following the load demand even if it
was not forecasted or planned at the beginning of the project: ease of techno-
economic expandability
- Increase the maintainability
- The total load is less than or equal to the rating of the single UPS (depending on Bypass Mains Bypass Mains
Normal Normal
the desired redundancy level) and is shared between all modules Dual Bus System with STS Mains Mains Normal
UPS 1 UPS 6 UPS 1 Mains UPS 6
STS2 or Hiswitch2,
LOAD
GP9335C 120-800kVA
Power Communication Options
When choosing the best system to protect your mission critical applications, an important consideration DC Ground Fault Indication
would be the software and communication options. As part of our commitment to provide the best solution - This provides indication of occurrence of battery ground
for you, we offer a wide range of sophisticated software and communication options for GP9335C Series. fault problems