55 -160kW
Multi-Unit Control
Panel
Outdoor Type
Variable Speed
Control
Multi-Unit Control
Separate Installation
Pressure Boost
Pressure Boost
Motor Output
(kW) 55 75 100 110 132 160
Model
Air-Cooled ○ ○ ○
VSD
(Vtype) Water-Cooled ○
Air-Cooled ○ ○ ○ ○ ○
Fixed Water-Cooled ○ ○ ○
Speed
Type Air-Cooled ○ ○ ○ ○ ○
Water-Cooled ○ ○ ○
1 2
(55/ 75/132/160kW)
New Air End Cooling Fan (Air-cooled Type)
75kW 12.6 13.2 13.0 100% Rotation Speed 70% Rotation Speed 100% Rotation Speed 70% Rotation Speed
Max.5%up (m /min)
3
Instrumental Panel
LCD Monitor Monitor Switch Menu Switch Digital Monitor
Oil Separator
Suction Filter
Cut-In Pressure1
[0.59MPa] Cut-Out Pressure 2
[0.57MPa]
Cut-In Pressure 2
[0.47MPa]
ECOMODE
Pressure (MPa)
0.65
Pressure
Cut-in Pressure
Energy-Saving Effect
(Start Loading) Load Unload Time→
0.69
Energy-Saving Max. 3%
Pressure (MPa)
0.59
±0.01MPa
(Constant Pressure Control)
Time
PQ WIDE MODE
Pressure Increase
0.9
Air Capacity Increase
Unit:m3/min 0.7
Pressure (MPa)
55-75kW
Discharge Pressure
0.6 Conventional VSD
MPa 0.45 0.50 0.60 0.70 0.85
Model
0.5
55kW 10.5 10.5 10.5 10.0 9.0
0.45
75kW 13.9 13.9 13.9 13.2 11.9 Pressure Decline
100kW 0
Discharge Pressure
100 105(%)
MPa 0.49 0.59 0.69 0.83 0.88 Air Consumption Rate
Model
Conventional
100kW 19.0 19.0 18.1 16.7 - VSD
5 6
System
Example of Compressed Air System Energy-Saving by System Structure
1 2
Filtration /1μm
(Dew Point under
Pressure/10℃ or below)
Example of Daily Air Demand
100%
50%
Oil Concentration/
0.01wtppm 25%
0:00
1:00
2:00
3:00
4:00
5:00
6:00
7:00
8:00
9:00
10:00
11:00
12:00
13:00
14:00
15:00
16:00
17:00
18:00
19:00
20:00
21:00
22:00
23:00
0:00
Air Filter Micro-Mist
Filter
3 4 5
Oil Concentration/
0.003wtppm
1
V-M Combination
(Dew Point under
Pressure/10℃ or below)
2 Units 2-12 Units 1-4 Units
Multi-Unit
3 Control with Multi VSD unit
Multi Roller EX
2
4
2 0 100 200
Full load or automatic stop
Air Consumption Rate(%)
V
Explanation
300
3 V S
200 All-time operation, all-time capacity adjustment, responding to
V S S air consumption at all area for power reduction
100
S S S
, or
V
Full load or automatic stop
0 100 200 300 400
Air Consumption Rate(%)
7 8
Flow Charts
VSD: Fixed Speed :
55 -110kW
Exhaust Air 1 Air Intake Filter
Model OSP-55M5AN OSP-75M5AN OSP-110M5ALI OSP-110M5WLI
2 Suction Throttle Valve
10 11 Compressed 3 Air End OSP-55S5AN OSP-75S5AN OSP-110S5ALI OSP-110S5WLI
Air Discharge Item・Unit
4 Main Motor Cooling Method - Air Cooled Water Cooled
12 5 Motor Nominal Output kW 55 75 110
Oil Separator Tank
Discharge Pressure MPa 0.7 [0.85]〈1.0〉 0.75 [0.85]
6 Rated
13 Oil Separator Discharge Capacity m3/min 9.8 [8.8]〈8.1〉 13.0 [11.7]〈10.7〉 20.0 [18.0]
7 Suction Pressure - Atmospheric Pressure
Oil Temperature Control Valve
Cooling Water Temperature
8 Temperature of Discharge Air ℃ Ambient Temperature + 15 or below
1
Oil Filter + 13 or below
6 Starter Type - Star − Delta (3 Contactor)
9 9 Minimum Pressure/Check Valve
Cooling Air
Driving System - 2-Pole TEFC Motor Gear Drive
Intake 10 After-cooler
Lubricating Oil - NEW HISCREW OIL 2000
11 Oil Cooler Lubricating Oil Filling Amount L 27 38 53
2 Output of Cooling Fan kW
8
Air into Air 1.5 (Inverter Control) 2.2 (Inverter Control) 3.0 (1.5×2) 0.1 (0.05×2)
5 12 Fan Motor
End Cooling Temperature ℃ 32 or below
-
13 Cooling Fan Water Quantity L/min 180
3 4 Discharge Air Pipe Diameter - Rc 2 Rc 2・1/2 [Flange]
7 External Dimension (W×D×H) mm 2,000×1,200×1,800 2,050×1,365×1,870
Oil Weight kg 1,420 1,720 2,360 2,260
Discharge Noise Level dB [A] 65 67 75 72
Cooling Air Flow Compressed Air Flow Lubricant Flow Note:
1. Capacity is the converted value at its inlet condition. For guaranteed values, contact 6. Compressor will be running at the ambient temperature of 45 deg. C. If the ambient
TH1: Thermistor (discharge air temp. 1) P: Pressure Gauge (for displaying oil separator tank internal pressure) your nearest dealer or HITACHI local representative offices. temperature is high, the maintenance period should be shortened.
TH2: Thermistor (discharge air temp. 2) 63E: Pressure Switch 2. Pressure is indicated as the gauge pressure. (ONLY applicable for 55/75kW)
PS: Pressure Sensor (for capacity control) 63SV: Pressure Differential Sensor of Air Intake Filter 3. Motor output values are indicated as motor nominal outputs. 7. Temperature of discharge air may vary from different environments.
4. Noise level is measured value at 1.5m in front and 1m height in an anechoic room, 8. Modulation control is available as option on both M type and S type (0.7/0.85MPa).
Above flow chart is for OSP-75M5AN as an example. under full load operation. It may vary in different operation conditions or Fixed modulation control operation is not possible on M type model. Make sure to
environments. install a properly sized air receiver tank.
5. Use the air compressor at a place where ambient temperature is between 0 and However, modulation control is NOT available on either M type or S type (1.0MPa) model.
40 deg C. 9. Earth leakage circuit breaker is NOT attached. Prepare it in advance.
Specifications 10. Specifications and outside view are subject to change without notice.