3.74 1.54
(95.0) 45º (39.1)
EXHAUST
2.13
(54.1)
6.23 INTAKE
90º (158.2)
6.5
(165.1)
Bolt Circle
3 Hole Options
Available 90º 7.44 0.87
(189.0) (22.1)
Configuring Your Blower
Please examine and check off the following steps to help you determine your requirements at a glance. Contact
your local AMETEK sales representative for a list of standard configurations. Other variations may require
additional lead time.
1
Step
Construction
o Bypass
Step
4 Motor Cooling Style
Working Inlet
Working Exhaust
Working Exhaust
5
Motor Cooling Inlet Dual Function
Step
2 Input Voltage
Generally, more flow on the “open” side of the curve reduces the
maximum pressure on the “sealed” side of the curve. Other fac-
tors (voltage, construction, stages, etc.) affect these curves so this
120 AC
o o 240 AC o Dual Voltage chart should be used for reference only. Always refer to individual
110-132 VAC 50/60 Hz 208-264 VAC 50/60 Hz 120-132 VAC 50/60 Hz | 18A data sheet for actual performance data.
208-264 VAC 50/60 Hz | 13A
240V models are optimized
100
and typically offer higher Dual Voltage offers the same
air performance than air performance when
dual voltage models supplied 120 or 240 VAC
80
Standard Flow
Step
3 Working Inlet Style 60
PRESSURE (in H₂O)
High Flow
0
0 50 100 150 200 250 300
Speed Control
PWM
o 1 Stage o 2 Stage o Non-Standard
o 3 Stage o 4 Stage
15 – 45 vdc max amplitude 30 Hz – 20 kHz frequency range
Generally, more pressure on the “sealed” side of the curve re-
duces the maximum flow on the “open” side of the curve. Always Speed control options allow the blower speed to be controlled
refer to individual datasheet for actual performance data. When via a configurable input signal. If the 0-10 vdc option is selected
operating on the left side of the chart (low flow) an increase in an input signal of 5 vdc is sent to the blower it will result in a half
the number of stages can give you substantially more pressure. speed command.
200
Pressure vs Flow
o Remote Potentiometer
180
Provides a 5 vdc output which can be connected to a remote
mounted (customer supplied) potentiometer.
160
o 4-20 mA o PWM
4 Stage
140
120
100 2 Stage
isolation from other system signals (noise).
80
ALSO SELECT: (Only applicable for 0-10VDC, 4-20mA,
60 1 Stage and PWM options)
40
20
o Pull Up o Pull Down
If speed command is lost, blower If speed command is
0
0 20 40 60 80 100 120 140 160 180
will operate at full speed. lost, blower speed will
SEALED FLOW (CFM) OPEN be reduced to zero.
Feedback Loop
Step
7 Mounting
o Open Loop o Closed Loop
o 5/16” Thru-Hole o 1/4” Thru-Hole
o 1/4-20 o M6 x 1 o #10-32
Wiring Harness (Check all required)
o M5 o M6 o No Harness (Customer supplied)
3 holes spaced 90º apart on a Power | AMP 350766-1
Ø 6.5" (165.1) bolt circle Speed | MOLEX 39-01-4051
Status | MOLEX 50-29-1662
o
Power Input Harness
Provided with flying leads
2
1
o Silicone Coating + SST Components LEAD LENGTH: (Not applicable for “No Harness” option)
120 35
Windjammer PRO Efficiency
Performance
30
100
EFFICIENCY (%)
25
80
and Efficiency 60
20
15
Data
Competor Efficiency
40
10
17% Increased
20 Flow 5
0 0
0 20 40 60 80 100 120 140
FLOW (CFM)
Windjammer PRO Performance Competor Performance Clean System Impedance
Windjammer PRO Efficiency Competor Efficiency Dirty System Impedance
Notes: Data presented represents blower performance at STANDARD AIR DENSITY, .075 l b/ f t 3 (29.92" Hg, Sea Level, 68°F).
Vacuum performance available upon request.
Technical Data
Sound Level @ Full Speed: 82dB (A) and 55 Sones
Construction
B = Bypass T = Thru-flow P = Peripheral S = Slotted shell (dual purpose)
Flow
S = Standard Flow H = High flow U = Ultra high flow
Fan System
1 = Single stage 2 = 2 Stage 3 = 3 Stage 4 = 4 Stage X = Non standard
Voltage
0 = Dual voltage 120/240 1 = 110/120 2 = 230/240
Rotor
F = Ferrite N=Neo Blend (standard) H= Neo Blend, High Energy Magnetization
Mounting Holes
A = (3X) 5/16" thru (standard) B = (3x) 1/4-20 C = (3X) M6 D = (3X) #10-32 E= (3X) M5
Protection
0 = Conformal coated PCBA (standard)
1 = Add silicone coating on PCBA
2 = Add silicone coating on PCBA with stainless steel components
Feedback Loop
0 = Open loop 1 = Closed loop
Speed Control
0 = Mechanical
1 = Remote potentiometer
2 = 0-10V pull down
3 = 0-10V pull up
4 = 4-20mA pull down
5 = 4-20mA pull up
6 = PWM pull down
7 = PWM pull up
Packaging
B = Bulk pack
S = Single pack
Printed in the U.S.A. © 2019, by AMETEK, Inc. All rights reserved. 919PDF (140125)