You are on page 1of 1

A B C D E F G H J K L M

1 1

CL 410%CV%109

2 2

PLAN

3 1800 I/S 1100 I/S 3


= = = =
2300
= =
300

550
4 4

2000
2300

1950
HATCHED AREA INDICATES HATCHED AREA INDICATES
EXTENT OF UHMWPE LINING EXTENT OF UHMWPE LINING T
TYPICAL BOTH SIDES TYPICAL BOTH SIDES O
N
6500

CL FLANGED SPLICE /
5 G N 5
I N O
IL TI
BEND LINE T A UC
E
D S TR
R N
F O CO
4500

ISOMETRIC VIEW E D R
SU FO
IS
6 6

350 NOTES:
= =
1. THIS DRAWING SHALL BE READ IN CONJUNCTION WITH STANDARD DRAWINGS AS
M:\11963 % Copler Gold\Drawings\410\COG 410%M%303.dft % 30/04/2013 % 02:44PM % paul.pruiti

900 350
= = NOTED AND GENERAL NOTES AS PER DRAWING 000%C%001
= = 2. PLATEWORK SHALL BE 6THK UNO
1060
= = 3. STIFFENERS SHALL BE 65x10FL AT MAX 600 CRS VERTICALLY AND HORIZONTALLY UNO
END ELEVATION 4. BOLTING FLANGES SHALL BE 75x10FL UNO HOLE SPACING = 200 MAX
ELEVATION 5. DIMENSIONS ARE TO INSIDE OF PLATE UNO
6. HOLES SHALL BE DIA 18 FOR M16 BOLTS UNO
7 7. FIT 4 x TYPE 2 LIFTING LUGS (WLL = 2 TONNE) TO EACH ASSEMBLY. REFER DETAIL ON 7
DRG COG 000%M%003
8. DESIGNATED INTERNAL FACES LINED WITH 8 THK UHMWPE LINING BOLTED
TO SITE SPECIFICATION
9. UNSPECIFIED MEMBERS UPE160
10. SURFACE PREPARATION AND PROTECTION SHALL BE IN ACCORDANCE WITH GRES
TECHNICAL SPECIFICATION TS15 % SYSTEM 2 % COLOUR 'LIGHT BEIGE'

EQUIPMENT No. 410%CH%104


WHEN IN DOUBT ASK DRAWN PBP 6/03/2013 ANAGOLD MADENCILIK
8 DO NOT SCALE CHECKED 8
D 19/04/2013 ISSUED FOR DETAIL DESIGN PBP LR DOB PSc DESIGNED
COPLER GOLD PROJECT
This drawing is confidential proprietary information and
C 27/03/2013 ISSUED FOR CLIENT REVIEW PBP DOB PSc furnished for the sole use of the recipient. Acceptance
ENGINEERING CONSULTANTS AND CONTRACTORS TECH APP
AGGLOMERATION AREA
B 26/03/2013 ISSUED FOR INTERDISCIPLINARY REVIEW PBP DOB PSc of the same constitutes an agreement that it will not
be copied or reproduced in any form, or given to any 179 Great Eastern Highway, Belmont ACN 121 542 738
PROJ APP
410%CV%109 PLOUGH DISCHARGE COLLECTION CHUTE (410%CH%104)
GENERAL ARRANGEMENT % PLAN COG 410%M%001 A 13/03/2013 PRELIMINARY INTERNAL REVIEW PBP DOB other party without written permission from
Western Australia. 6104

A1 SCALE 1:20 JOB No DRG No


COG 410%M%303 REV
D
Phone: (08) 6272 6000
REFERENCE DRAWING DRAWING NUMBER REV DATE REVISION DRN CHK TECH PROJ GR ENGINEERING SERVICES. Fax: (08) 6272 6001 CLIENT APP 11963