You are on page 1of 1

QPID 227 en 4.9.

134 4099977296

Space between pressure plate and supporting column


FRAME PLATE should be kept free from fixed installations! PRESSURE PLATE
450 25 (MOVABLE)
1000 *) / 600 **) 25 A

(110)
The Proprietary Information shall remain the exclusive property of Alfa Laval and shall only be used for the purpose of evaluating Alfa Laval´s quotation. The Proprietary Information may not, without the written consent of

*)
Recommended S4 S1
free space
for opening
and closing

640

854
890
to be applied
on both sides
Data, specifications, and other information of a technological nature set out in this document and submitted by Alfa Laval to you (Proprietary Information) are the intellectual property of Alfa Laval.

**) S3 S2
Free space can
be reduced to
this distance on 140
one of the sides

12
154
8

320 162
81 70

40
S1
S4

21
S2
PRESSURE PLATE S3

21

240
280
320
FRAME PLATE

448 28
Alfa Laval, be used or copied, reproduced, transmitted or communicated or disclosed in any other way to a third party.

ASME B16.5 Class 150 NPS 2


S1, S2, S3, S4
TIGHTENING BOLTS 4 x M20, L = 330 mm
2 x M20, L = 330 mm
A-A:
100
ALLOY 316
85
APPROX. OUTER DIMENSIONS
61
LENGTH 640 mm
58 70
WIDTH 330 mm
HEIGHT 880 mm
A APPROX. WEIGHTS
NET WEIGHT, EMPTY 140 kg
WEIGHT FULL OF WATER 153 kg
121
86

PLATE MATERIAL ALLOY 316


A PLATE THICKNESS 0.5 mm
GASKET EPDMC ClipGrip™

5/8"-11 UNC (x4)


All dimensions in millimeters (mm)
NO. OF UNITS 1 DESIGN PRESSURE DESIGN TEMPERATURE TEST OPERATING
MAX. MIN. MAX. MIN. PRESSURE MAX. TEMP.
ML ML 6.70 l/s 10.0 bar 0.0 bar 150.0 °C -30.0 °C 14.3 bar 150.0 °C
MH MH 6.70 l/s 10.0 bar 0.0 bar 150.0 °C -30.0 °C 14.3 bar 150.0 °C
DRAWING Anagold Hex
GASKETED PLATE HEAT EXCHANGER

T6-PFG Do not use this drawing for foundation bolting or piping layout

PED Category II DATE 3/5/21


REVISION 0