AIRBORNE ULTRASOUND

LEAK MANAGEMENT: FIND-AND-FIX LEAKS

1 2 3 4

Pre-Survey Checks Start Survey Pinpoint and Tag Repair and Document

Pinpoint the exact location


of the leak by moving closer
to the source, if safe to do so.

Safety: Adjust headphone and instrument Safety:


Check safety policies. volume to the minimum Isolate system to be worked on.
Check working environment necessary for the job. Lock-out and tag-out system machines.
for hazards. Intrinsically safe Protect from hearing damage!
equipment required?
Reduce instrument amplification
“sensitivity” as you approach leak.

Bleed off any excess


Sweep target area from left to right and system pressure.

AK
Review compressed

LE
top to bottom.
air system layout/drawings.
Control any background noise or
sound with shielding techniques.

PSI
Repair defect to eliminate leak.
Locate any leaks.
Check gauge for
expected pressures.
Manage your reflections:
Verify that the true source of the leak
is being detected and that the signal is
AK

not being reflected off nearby objects


LE

or walls.
AK
LE

Update the status of the repaired leaks


Adjust instrument amplification in your LEAKReporter app.
Inspect the area, locate pipes,
“sensitivity” as required.
valves and fittings.
AK
LE
AK
LE

AK

Create a survey and document your Notify supervision and operations that
LE

Equipment Check: leaks in pictures with the repair task is completed.


Re-adjust headphone and instrument
K
AAK
AK

.
1 Personal Protective Equipment (PPE) LEAKReporter app.
LLEE

volume if leak is nearby.


LE

2. Ultrasound instrument
AK
LE

3. Headphones
4. Extended distance sensor
5. Flexible sensor
6. Parabolic sensor
7. Shielding cloth
AK
LE

8. Tags and marker/pen Once system is back online


AK

9. Defect log Manage repairs and evaluate costs on re-survey the area and record the new
LE

Control your measurement position. leakreporter.sdtultrasound.com


AK

10. Flashlight value (dBuV) for documentation.


LELE
AK

© Copyright 2018 by SDT INTERNATIONAL. No copying or reproduction of this information, in any form whatsoever, may be undertaken without
KA

express written permission of SDT INTERNATIONAL. WARNING: The content of this graphic is a basic guide to leak detection. In practice, more details
EL

must be taken into account. SDT INTERNATIONAL is not responsible for any damage or injury arising out of the use of this document.
This infographic is the result of a collaborative development project between SDT Ultrasound Solutions and LUDECA Inc - www.ludeca.com sdtultrasound.com

You might also like