Operation Department
Plant/Apparatus:
50LCB11AP001 CONDENSATE EXTRACTION PUMP 1 UNIT 50
Task:
Internal inspection
Status:
There is abnormal noise inside pump casing unit still on load
Particular Aspects:
Agreement from Control Person to release the plant/apparatus
Basic safety rule A3.2 when internal access required shall purged if residue content could cause
danger.
Danger : 1. asphyxiation from residue of chemical
2. falling.
3. noise ( when unit on load ).
Reference:
Powergen safety rules A3.2
Isolation List:
1. 50LCB11AP001-MM01 CEP 1 MOTOR 10 KV : SWITCHOFF,RACKEDOUT
EARTHING,LOCKED
2. 50LCA11AA003 CEP 1 DISCH. VALVES : SWICTH OFF, SHUT, LOCKED
3. 50LCA11AA004 CEP 1 DISCH. BY PASS VALVES : SHUT LOCKED
4. 50LCA11AA001 CEP 1 SUCT. VALVES : SHUT LOCKED
5. 50LCA11AA501 CEP 1 VENT VALVES : SHUT LOCKED
6. 50LCA11AA502 CEP 1 VENT VALVES : SHUT LOCKED
7. 50LCA11AA401 CEP 1 DRAIN VALVES : OPEN LOCKED
8. 50LCA11AA402 CEP 1 DRAIN VALVES : OPEN LOCKED
9. 50LCW13A001 CEP 1 SEALING CONDENSATE VALVES : SHUT LOCKED
Paiton II Power Station – Indonesia Didik Ari P/M:/Authorisation/SAP Training Isolation Exercise 1
PT PowerGen Jawa Timur
Operation Department
Candidate Remarks
Date of exercise
Assessor Remarks