You are on page 1of 1

Design Of Columns

Inputs
Fcu = 25 (N/mm2)
Fy = 360 (N/mm2)
Pu (kN) = 707 kN
t in Length (m) = 0.4 m
b out Weidth (m) = 0.4 m
H Height in (m) = 5.3 m Height out (m) = 5.3 m
Tbeam in (m) = 0.5 m Tbeam out (m) = 0.5 m
INPLAN OUT OF PLAN
Col Type = Unbraced Col Type = Unbraced
K Top = Case 2 K Top = Case 2
K Bot = Case 2 K Bot = Case 2

Outputs
H˳in (m) = 4.8 m H ˳out (m) = 4.8 m
λbin = 18 Long col Min RFT TO λ % 1.186
λbout = 18 Long col
Ϭ= 0.0648 m
Madd = 45.8136 KN.M
Mext = 450 KN.M
Mtot = 495.8136 KN.M
DESIGN Column is Long
e = 0.7013 m
Ac short required= 0mm2 e/t= 1.7532 Calc es
As short = 0mm2 es= 0.8513 m
Area Provided = 160000 mm2 Ms= 601.86 KN.m
C1= 1.4267
J= Err:502
As Long= Err:502 mm2
As min Long= 1897.6 mm2
As Req= Err:502 mm2
ø= 25 N= Err:502