Republic of the Philippines

PROVINCE OF LA UNION
City of San Fernando

A-1 OFFICE OF THE BUILDING OFFICIAL


PERSPECTIVE
VICINITY MAP
SITE DEVELOPMENT PLAN
LEGENDS AND SYMBOLS

A-2
BASEMENT 1ST,2ND 3RD 4TH FLOOR PLAN
DOORS AND WINDOWS SCHEDULE
SECTION

A-3
FRONT VIEW ELEVATION
LEFT SIDE VIEW ELEVATION
REAR VIEW ELEVATION
RIGHT SIDE VIEW ELEVATION

S-1 FOUNDATION PLAN


1ST,2ND,3RD,4TH AND ROOF FRAMING PLAN
COLUMN DETAILS
BEAM DETAIL AND SCHEDULE
FOOTING SECTION

S-2
GENERAL NOTES

E-1
BASEMENT,1ST FLOOR,2ND FLOOR,3RD FLOOR & 4TH FLOOR
LIGHTING AND POWER LAYOUT

1 PERSPECTIVE
NTS E-2
CIRCUIT DIAGRAM,ELECTRICAL NOTES AND LEGENS,
COMPUTATIONS

THIS SITE P-1


BASEMENT,1ST FLOOR,2ND FLOOR,3RD FLOOR & 4TH FLOOR
8.19m. WATER AND PLUMBING LAYOUT
1.08m.

1.04m.

P-2
SEPTIC TANK DETAIL
WATER LINE ISOMETRY

BUILDING PLUMBING ISOMETRY


3.88m.

3.88m.

TYPICAL REFERENCE MARK


TO DETAILS & ORIENTATIONS
3.00m.

3.00m.

3METERS FRONTAGE AS PER DETAIL NUMBER


TYPICAL REFERENCE
SHEET NUMBER WHERE KEY TO DETAIL
BUILDING CODE REQUIREMENT AND DETAIL IS SHOWN

HIGHWAY CLEARANCE
DOOR REFERENCE
DOOR NUMBER
KEY

0.87 7.99m.
WINDOW REFERENCE
WINDOW NUMBER
KEY

SECTION INDICATION
ARROW INDICATES TYPICAL REFERENCE
DIRECTION OF CUT KEY TO FULL SECTION
SHEET NUMBER

SECTION INDICATION
BEND INDICATES TYPICAL REFERENCE
DIRECTION OF CUT KEY TO WALL SECTION
SHEET NUMBER

ROOM NUMBER
TYPICAL REFERENCE
KEY TO ROOM SECTION
SHEET NUMBER

DRAWING NUMBER
TYPICAL REFERENCE
KEY TO ELEVATION
SHEET NUMBER

WALL THICKNESS TYPICAL REFERENCE


INDICATION KEY TO WALL THICKNESS

FLOOR LEVEL TYPICAL REFERENCE


INDICATION KEY TO FLOOR LEVEL

2 SITE DEVELOPMENT PLAN 3 VICINITY MAP


1:100 M NTS

NOTE: ALL DISCREPANCY MUST BE VERIFIED WITH THE ARCHITECT AND ENGINEER
ARCHITECT / ENGINEER REVISIONS OWNER / ADMINISTRATOR PROJECT TITLE: DRAWN BY: SHEET CONTENTS SHEET NO.:

DESIGNED BY:

MR. ELMER ATUD


PRC REG. NO:
SIGNATURE OVER PRINTED NAME

PTR NUMBER:
SIGNATURE OVER PRINTED NAME
PROPOSED 4-STOREY BUILDING CHECKED BY:

APPROVED BY:
AS SHOWN A-01
VALID UNTIL: DATE ISSUED:

TIN NUMBER: PLACE ISSUED: OWNER APPROVAL: LOCATION: BRGY. ILOCANOS NORTE, CITY OF SAN FERNANDO, LA UNION DATE AND PLACE:
VERIFY 1.47m. 1.93m. 3.03m.

1.70m. 2.62m. 3.63m.


2.19m.

1.23m.
BALCONY
2.67m.
2.79m.
OPEN SPACE
LIVING

2.67m.
FOYER

APEX

OPEN SPACE CR
BEDROOM UP 2.32m. 3.15m. 2.91m.
OPEN SPACE

3.30m.
3.18m.

DINING
2 GROUND FLOOR PLAN
1:100 M FINISH FLOOR LINE FOURTH FLOOR

VERIFY OPEN SPACE


4.22m. 3.07m.
3.40m. 3.03m. CR

OPEN SPACE
ROOF DECK/BALCONY
DN

1 BASEMENT FLOOR PLAN FINISH FLOOR LINE THIRD FLOOR

1.23m.
1:100 M

CR
OPEN SPACE OPEN SPACE

2.67m.
OPEN SPACE

UP
1.48m. 2.58m. 3.27m. 3.15m.
FINISH FLOOR LINE SECOND FLOOR
OR VERIFY 2.01m. 2.32m. 3.15m. 2.91m.
OPEN SPACE CR
3 SECOND FLOOR PLAN
1:100 M OPEN SPACE
2.67m.

1.49m. 2.48m. 2.97m. 3.03m.


DN FINISH FLOOR LINE GROUND FLOOR
OR VERIFY
2.30m.

ROAD
DN RESIDENTIAL CR

1.23m.
RESIDENTIAL
2.02m. 2.58m. 3.27m. 2.90m.
OPEN SPACE
FINISH FLOOR LINE BASEMENT
5 4TH FLOOR FLOOR PLAN

2.67m.
1:100 M
UP
6 SECTION THRU AA' 7 SECTION THRU BB'
1:100MTS 1:100MTS
1.43m. 3.15m. 2.91m.

4 THIRD FLOOR PLAN


1:100 M

0.70m.
0.70m.
0.70m.
0.70m.
0.70m.
0.70m.
0.70m.
0.70m. 0.60m.0.60m.0.60m. 1.60m. 1.20m. 0.60m.

1.50m. 0.60m.
0.90m. 1.20m.

0.90m. 1.20m.
0.50m. 1.60m.

2.10m.

FINISH FLOOR LINE


ANALOK WINDOW ANALOK WINDOW ANALOK WINDOW ANALOK WINDOW ANALOK WINDOW
2.00m. 1.50m. 2.30m. 0.90m. 0.70m.
2.10m.
2.10m.

2.10m.

2.10m.
2.10m.

8 DOORS AND WINDOW SCHEDULE


1:50 M

D-1 D-2 D-3 D-4 D-5


10MM SAFETY GLASS DOOR
DESCRIPTION SLIDING GLASS DOOR DESCRIPTION SLIDING GLASS DOOR DESCRIPTION ON ALUMINUM FRAMED SLIDING DESCRIPTION WOOD FLUSH DOOR DESCRIPTION PVC DOOR
PANELS.

QUANTITY QUANTITY QUANTITY QUANTITY 2 SETS QUANTITY 5 SETS


2 SETS 3 SETS 1 SET

LOCATION LOCATION 1ST &2ND FLOOR/FOYER LOCATION 3RD FLOOR LOCATION BEDROOM AND 4TH FLOOR LOCATION CR
GROUND FLOOR

REVISIONS PROJECT TITLE: OWNER / ADMINISTRATOR SHEET CONTENTS SHEET NO.:

PROPOSED 4-STOREY BUILDING MR. ELMER ATUD


AS SHOWN
SIGNATURE OVER PRINTED NAME A-02
PRC NO.: PLACE ISSUED: PRC NO.: TIN NO.: CADD BY:
LOCATION: BRGY. ILOCANOS NORTE, CITY OF SAN FERNANDO, LA UNION
PTR NO.: DATE ISSUED: PTR NO.: DATE/PLACE MOBILE NO.
APEX

2.93m.
FINISH FLOOR LINE FOURTH FLOOR

3.35m.
FINISH FLOOR LINE THIRD FLOOR

3.35m.
FINISH FLOOR LINE SECOND FLOOR

3.35m.
0.60m.
FINISH FLOOR LINE GROUND FLOOR

0.40m.
ROAD

0.40m.2.90m.
FINISH FLOOR LINE BASEMENT

1 FRONT ELEVATION 2 REAR ELEVATION


1:100MTS 1:100MTS

APEX

2.90m.
3.35m. FINISH FLOOR LINE FOURTH FLOOR

FINISH FLOOR LINE THIRD FLOOR


3.35m.

FINISH FLOOR LINE SECOND FLOOR


3.35m.

0.60m.

FINISH FLOOR LINE GROUND FLOOR


0.40m.

ROAD
2.90m.
0.40m.

FINISH FLOOR LINE BASEMENT

3 LEFT SIDE ELEVATION 4 RIGHT SIDE ELEVATION


1:100MTS 1:100MTS

REVISIONS PROJECT TITLE: OWNER / ADMINISTRATOR SHEET CONTENTS SHEET NO.:

PROPOSED 4-STOREY BUILDING MR. ELMER ATUD


AS SHOWN
SIGNATURE OVER PRINTED NAME A-03
PRC NO.: PLACE ISSUED: PRC NO.: TIN NO.: CADD BY:
LOCATION: BRGY. ILOCANOS NORTE, CITY OF SAN FERNANDO, LA UNION
PTR NO.: DATE ISSUED: PTR NO.: DATE/PLACE MOBILE NO.
DN DN

UP UP

1 BASEMENT LIGHTING LAY-OUT 2 GROUND FLOOR LIGHTING LAY-OUT 3 SECOND FLOOR LIGHTING LAY-OUT 4 THIRD FLOOR LIGHTING LAY-OUT 5 FOURTH FLOOR LIGHTING LAY-OUT

DN DN

UP UP

6 BASEMENT POWER LAY-OUT 7 GROUND FLOOR POWER LAY-OUT 8 SECOND FLOOR POWER LAY-OUT 9 THIRD FLOOR POWER LAY-OUT 10 FOURTH FLOOR POWER LAY-OUT

REVISIONS PROJECT TITLE: OWNER / ADMINISTRATOR SHEET CONTENTS SHEET NO.:

PROPOSED 4-STOREY BUILDING AS SHOWN


MR. ELMER ATUD
SIGNATURE OVER PRINTED NAME E-01
PRC NO.: PLACE ISSUED: PRC NO.: TIN NO.: CADD BY:
LOCATION: ILOCANOS NORTE SAN FERNANDO CITY, LA UNION
PTR NO.: DATE ISSUED: PTR NO.: DATE/PLACE MOBILE NO.
1. ALL ELECTRICAL INSTALLATIONS HEREIN
SHALL BE DONE IN ACCORDANCE WITH THE
LATEST EDITION OF THE PHILLIPINES
ELECTRICAL CODE AND ITS IMPLEMENTING
RULES AND REGULATIONS.

SOURCE 2. POWER SERVICE TYPE TO BE USED SHOULD


BE SINGLE PHASE, TWO WIRES, 22O VOLTS.
PANEL BOX 01
LOAD SCHEDULE
3. ALL MATERIALS TO BE USED MUST BE BRAND
CKT NO. OF TOTAL WIRE NEW AND OF APPROVED TYPE AND QUALITY.
LOAD DESCRIPTION OUTLETS
WATTS
WATTS
VOLTS AMP AT AF POLE CONDUIT
NO. SIZE
1 LIGHTING OUTLET
18 40 720
220
3.27 15 50
#14 THHN
SERVICE ENTRANCE AT 100 A
ALL ELECTRICAL WIRINGS SHALL BE IN PVC
2
2 LIGHTING OUTLET
15 40 600
220
2.73 15 50 2
#14 THHN CONDUIT WITH THE NECESSARY FITTINGS AND
3 LIGHTING OUTLET
14 40 560
220
2.55 15 50 2
#14 THHN
100 AMP ACCESSORIES.
4 LIGHTING OUTLET
16 40 640
220
2.91 15 50 2
#14 THHN
CRT LIGHTING 15 AMP 15 AMP LIGHTING CRT
5 CONVENIENCE OUTLET 6
300 1800
220
8.18 20 ## #
#12 THHN
1 2
6 CONVENIENCE OUTLET 6
300 1800
220
8.18 20 ## #
#12 THHN 4. ALL DUAL CONVENIENCE OUTLETS SHALL BE
7 CONVENIENCE OUTLET 6
300 1800
220
8.18 20 ## #
#12 THHN FLUSH TYPE, 400mm. ABOVE FINISHED FLOOR
CRT LIGHTING LIGHTING CRT
8 CONVENIENCE OUTLET 6
300 1800
220
8.18 20 ## #
#12 THHN
3
15 AMP 15 AMP
4 LINE. ALL SWITCHES SHALL BE 1400mm. ABOVE
9 CONVENIENCE OUTLET 6 220 #12 THHN

10 AIR CONDITION UNIT 1


300 1800
220
8.18 20 ## #
#12 THHN
FINISHED FLOOR LINE.
900 900 4.09 20 ## #
11 AIR CONDITION UNIT 1 220 #12 THHN
CRT Convenience Convenience CRT
900 900 4.09 20 ## # 20 AMP 20 AMP
12 AIR CONDITION UNIT 1
900 900
220
4.09 20 ## #
#12 THHN 5 Outlet Outlet 6 5. ALL ELECTRICAL WORKS HEREIN SHALL BE
13 AIR CONDITION UNIT 1 220 #12 THHN
900 900 4.09 20 ## #
DONE UNDER THE DIRECT SUPERVISION OF A
14 AIR CONDITION UNIT 1
900 900
220
4.09 20 ## #
#12 THHN
CRT Convenience 20 AMP 20 AMP Convenience CRT DULY REGISTERED MASTER ELECTRICIAN
15 AIR CONDITION UNIT 1
900 900
220
4.09 20 ## #
#12 THHN 7 Outlet Outlet 8
16 AIR CONDITION UNIT 1
900 900
220
4.09 20 ## #
#12 THHN SUBJECT HOWEVER TO THE APPROVAL OF A
17 SPARE 1
1000 1000
220
4.55 20 ## #
#12 THHN
CRT Convenience ACU CRT
PROFESSIONAL ELECTRICAL ENGINEER.
18 SPARE 1
1000 1000
220
4.55 20
#12 THHN 20 AMP 20 AMP
## # 9 10
Outlet
TOTAL 100 #8 THHN
9960 19820 3960 90.09

CRT ACU 20 AMP 20 AMP ACU CRT


11 12

COMPUTATION:
CRT ACU 20 AMP 20 AMP ACU CRT
13 14
IFL = 11600 USE: 80% Demand Factor
220V = 0.80 X 90.09 AT = 72.07 A
= 90.09 AT CRT ACU 20 AMP 20 AMP ACU CRT
15 16

CRT SPARE 20 AMP 20 AMP SPARE CRT


17 18

PANEL BOX

LIGHTING OUTLET

3 LOAD COMPUTATION 4 RISER DIAGRAM 5 ELECTRICAL NOTES & LEGEND

REVISIONS PROJECT TITLE: OWNER / ADMINISTRATOR SHEET CONTENTS SHEET NO.:

PROPOSED 4-STOREY BUILDING AS SHOWN


MR. ELMER ATUD
SIGNATURE OVER PRINTED NAME E-02
PRC NO.: PLACE ISSUED: PRC NO.: TIN NO.: CADD BY:
LOCATION: ILOCANOS NORTE SAN FERNANDO CITY, LA UNION
PTR NO.: DATE ISSUED: PTR NO.: DATE/PLACE MOBILE NO.
FD FD FD
LAV
FD DN FD
DN LAV
FD
LAV
FD

WC WC WC

FD
LAV
WC

EXISTING SEPTIC

UP UP

1 BASEMENT PLUMBING LAY-OUT 2 GROUND FLOOR PLUMBING LAY-OUT 3 SECOND FLOOR PLUMBING LAY-OUT 4 THIRD FLOOR PLUMBING LAY-OUT 5 FOURTH FLOOR PLUMBING LAY-OUT

LAV
DN DN LAV
LAV LAV

UP WC UP WC UP WC UP WC
SH
LAV

WC

UP UP

6 BASEMENT WATERLINE LAY-OUT 7 GROUND FLOOR WATERLINE LAY-OUT 8 SECOND FLOOR WATERLINE LAY-OUT 9 THIRD FLOOR WATERLINE LAY-OUT 10 FOURTH FLOOR WATERLINE LAY-OUT

PROJECT TITLE: OWNER SHEET CONTENTS SHEET NO.:

PROPOSED 4-STOREY BUILDING AS SHOWN


MR. ELMER ATUD
SIGNATURE OVER PRINTED NAME P-01
PRC NO.: TIN NO.: PRC NO.: TIN NO.: CADD BY: MCJ
LOCATION: ILOCANOS NORTE SAN FERNANDO CITY, LA UNION
PTR NO.: DATE: PTR NO.: DATE/PLACE MOBILE NO.
3.00
0.75 0.75 1.50

10mm THICK REINFORCE CONCRETE SLAB W/ 10 1. ALL PLUMBING WORKS INCLUDED HEREIN SHALL BE EXECUTED ACCORDING TO
THE LATEST PROVISIONS OF THE PHILIPPINE PLUMBING CODE, THE NATIONAL
0.60 BUILDING CODE OF THE PHILIPPINES & THE RULES AND REGULATIONS OF THE CITY/
MUNICIPALITY.

2. ALL PLUMBING SANITARY WORKS SHALL BE EXECUTED IN THE BEST AND MOST
CO THOROUGH MANNER UNDER THE SUPERVISION OF A REGISTERED SANITARY
CO "4 PVC ENGINEER AND TO THE SATISFACTION OF THE OWNER AND/ OR THE DESIGNER.
INLET PIPE

0.60
MANHOLE MANHOLE MANHOLE 3. COORDINATE THE DRAWINGS WITH OTHER RELATED DRAWINGS AND

1.50
SPECIFICATIONS; THE ARCHITECT/ ENGINEER SHALL BE NOTIFIED IMMEDIATELY OF
ANY DISCREPANCY FOUND THEREIN.
OUTLET PIPE
CO CO 4. ALL ROUGHING-INS SHALL BE INSTALLED AS INDICATED ON PLANS, ANY
RELOCATION REQUIRED FOR PROPER EXECUTION OF OTHER TRADES BE WITH
PRIOR APPROVAL OF THE ARCHITECT/ ENGINEER.
SPACED @0.60 M. O. C.
5. PROPOSED SANITARY UTILITIES SHALL CONFORM TO THE ACTUAL LOCATION,
PLAN DEPTH AND INVERT ELEVATION OF ALL EXISTING PIPES AND STRUCTURES AS
VERIFIED BY THE CONTRACTOR.

6. ALL SLOPES FOR HORIZONTAL DRAINAGE SHALL MAINTAIN ONE (1%) MINIMUM,
3.00
UNLESS OTHERWISE SPECIFIED.
0.75 0.75 1.50
7. ALL PIPE DIAMETERS ARE NOMINAL AND IN MILLIMETERS AND ALL DIMENSIONS
MANHOLE 0.60X ARE IN METERS UNLESS OTHERWISE SPECIFIED.
0.60 PROVIDE W/
LIFTING HANDLE 8. ALL PIPES SHALL BE ADEQUATELY SUPPORTED AND TERMINATION OF VTR FROM
MANHOLE MANHOLE
CO CO CO CO
0.20 ROOF SHALL NOT BE LESS THAN 300mm.

0.05 AIR SPACE INLET PIPE 9. THE CONTRACTOR SHALL VERIFY ALL EXISTING UTILITIES AT THE SITE AND
COORDINATE THE WORK WITH THE SEWER LINE EFFLUENT DISPOSAL POINT AND
OUTLET PIPE WATERLINE SERVICE CONNECTING POINT.
TO STREET DIGESTIVE
SEWER OR CHAMBER
10. SIZE OF WATER SUPPLY PIPES TO FIXTURES SHALL BE IN A ACCORDANCE W/ THE

2.00
DISPOSAL LEACHING LEACHING
FIELD WELL WELL MANUFACTURER'S INSTRUCTIONS.

11. ALL DIMENSIONAL LOCATIONS OF FIXTURES, DRAINS, RISER AND PIPE CHASE
FINE GRAVEL SPACED @0.60 M. O. C. SHALL BE VERIFIED ON THE ARCHITECTURAL DRAWINGS AND MANUFACTURER'S
0.10 0.10 CATALOGUE.

REINFORCE CONCRETE SLAB W/ 10


12. PROVIDE AS-BUILT DRAWINGS OF THE ROUGH-INS OF THE PROPOSED SYSTEM AS
REINFORCE PER APPROVAL OF THE SANITARY ENGINEER.
CONCRETE FOOTING W.
13. THE CONTRACTOR IS RESPONSIBLE FOR THE TESTING OF THE ENTIRE SYSTEM OF
BARS SPACED @0.30
M. O. C. DRAINS, WASTE AND VENT PIPING. WATER TEST AND DISINFECTION SHALL BE IN
ACCORDANCE WITH THENATIONAL PLUMBING CODE AND
SANITATION CODE OF THE PHILIPPINES.

13 SEPTIC TANK DETAIL

VTR/ VST

FIN. WALL LINE LAV


CLEANOUT
COVER wc

FD
FIN. FLOOR LINE

C.O.

CLEAN OUT THRU WALL HB

POURED
CONCRETE
CLEANOUT
COVER
GV
FIN. FLOOR LINE

CV

CLEAN OUT THRU FLOOR CB

11 ISOMETRIC PLUMBING LAY-OUT 12 ISOMETRIC WATER LINE LAY-OUT 14 PLUMBING DETAIL 15 PLUMBING NOTES & LEGEND

PROJECT TITLE: OWNER SHEET CONTENTS SHEET NO.:

PROPOSED 4-STOREY BUILDING AS SHOWN


MR. ELMER ATUD
SIGNATURE OVER PRINTED NAME P-02
PRC NO.: TIN NO.: PRC NO.: TIN NO.: CADD BY: MCJ
LOCATION: ILOCANOS NORTE SAN FERNANDO CITY, LA UNION
PTR NO.: DATE: PTR NO.: DATE/PLACE MOBILE NO.
0.125m Thk. 0.125m Thk. 0.125m Thk.
Concrete Slab with 0.125m Thk. Concrete Slab with Concrete Slab with
10mmDiameterG40 Concrete Slab with 10mmDiameterG40 10mmDiameterG40
spaced 0.15m O.C. 10mmDiameterG40 spaced 0.15m O.C.
1.60m. 1.36m. 2.09m. 2.90m. on bothways REST spaced 0.15m O.C.
spaced 0.15m O.C.
on bothways REST on bothways REST
ON 1.0mm STEEL on bothways REST ON 1.0mm STEEL ON 1.0mm STEEL
DECK ON 1.0mm STEEL DECK DECK
DECK

1.04m.

1.04m.
2.72m. 2.09m. 2.90m.
2.72m. 2.09m. 2.90m. 2.72m. 2.09m. 2.90m. 2.72m. 2.09m. 2.90m.
2.72m. 2.09m. 2.90m.
C2 C3 B3 C3 B3 C3 B3 C3 B3 B3 B3 C3

.
C3 C3 C3

1.03m

.
C1A C1A C1A C1A C3 C3 C3 C3

1.00m.

1.03m
B3 B3 B3 C4 C4 C4 C4

1.00m.
C3 C3 C3 C3 RB2 RB2 RB2 RB2

1.03m

.
.

1.00m.
.

1.03m
1.03m
B3 B1' B1' B2' B1'
1.96m

B1' B1' B1' B1' B1' B1'

1.00m.
1.00m.
RB RB

1.89m.
B3 RB1 RB1 RB1 RB1 RB
RB1
B1' B3 B2' B1' B1' B1' RB RB
B3 B3
B4 B4 B4 B4 B4 B4 B4 RB1 RB1 RB1 RB1
C1A C1A C1A C1B
C1 C1B

.
C1A C1A

2.19m
B4 B4 B4 B4 C1A

.
C1A C1A

2.13m.
C1B

2.19m
C1A C1B

2.13m.
C2

2.19m

.
.

2.13m.
C1A C1A C1A C1A

2.19m
2.19m
B1 B1

2.13m.
B1 B2 B1 B1 B2 B1

2.13m.
B3 B2 B3 B3 B2 RB1 RB1 RB1 RB1 RB1
RB RB RB
B1 B2 B3 B2 B3 B1 RB
2.64m.

2.64m.
C3 C1B C1B
C3 C1A C1A C1A RB1 RB1 RB1 RB1 C1B C1B
B4 B4 B4 B4

0.80m.

0.80m.
0.80m.

0.80m.
C1A C1A C1A
B4 B4 B4 B4

0.80m.

0.80m.
RB1 RB1

0.80m.

0.80m.
B4 B4 B4 B4 RB1 RB1 RB1
C1A B1' B1' B1' B1' B2 RB2 RB2 RB2
C1A C1A RB RB
RB RB
B3

2.64m.

2.64m.
B1' B3 B1' B1' B3 B1' B1' C3 C3 C3 C3
C3 C3 C3 C3
C3 B3 C3 B3 C3 B3 C3
C4 C4 C4 C4
C2 C2 C2 C2 B1 B2 B1 B2 B1 3.45m. 2.09m. 2.90m.
C2 B3 B3 B3 3.45m. 2.09m. 2.90m. 3.45m. 2.09m. 2.90m.
3.45m. 2.09m. 2.90m.
2.09m. 1.36m. 2.09m. 2.90m.

B3 B3 B3 B3
2.09m. 1.36m. 2.09m. 2.90m. 5 4TH FLOOR FRAMING PLAN 6 ROOF BEAM PLAN
3 SECOND FLOOR FRAMING PLAN 4 3RD FLOOR FRAMING PLAN 1:100MTS
1:100MTS
2 GROUND FLOOR FRAMING PLAN 1:100MTS
1:100MTS

1:100MTS

PLAN CODE
SECTION
B H RS MID LS REINFORCEMENT

FOUNDATION - 5-D20MM CONT. RSB 5-D20MM CONT. RSB 5-D20MM CONT. RSB 1Omm Ø STIRRUPS SPACED
BASEMENT @ 3 - 0.05M, 3-0.10M, REST
COLUMN @ 0.15M O.C.
1M WIDTH STRIP 1M WIDTH STRIP B1 300 600 2-D16MM CONT. RSB 2-D16MM CONT. RSB 2-D16MM CONT. RSB
300X300
20MM @ 50MM 20MM @ 50MM B1' ADD EXTRA TOP BAR
500X600 5-D20MM CONT. RSB 5-D20MM CONT. RSB 5-D20MM CONT. RSB
20MM

3-D20MM CONT. RSB 3-D20MM CONT. RSB 3-D20MM CONT. RSB 1Omm Ø STIRRUPS SPACED
@ 3 - 0.05M, 3-0.10M, REST
@ 0.15M O.C.
B2 300 600 2-D16MM CONT. RSB 2-D16MM CONT. RSB 2-D16MM CONT. RSB

B2' ADD EXTRA TOP BAR


3-D20MM CONT. RSB 3-D20MM CONT. RSB 3-D20MM CONT. RSB 20MM

3-D16MM CONT. RSB 2-D16MM CONT. RSB 2-D16MM CONT. RSB


1Omm Ø STIRRUPS SPACED
B3 250 400 2-D16MM CONT. RSB 2-D16MM CONT. RSB 2-D16MM CONT. RSB
@ 3 - 0.05M, 3-0.10M, REST
3-D16MM CONT. RSB 2-D16MM CONT. RSB 2-D16MM CONT. RSB @ 0.15M O.C.

4-D20MM CONT. RSB 4-D20MM CONT. RSB 4-D20MM CONT. RSB


LONGITUDINAL BOTTOM BARS TRANSVERSE BOTTOM BARS
LONGITUDINAL TOP BARS TRANSVERSE TOP BARS
20MM @ 200MM O.C 20MM @ 200MM O.C
20MM @ 200MM O.C. 20MM @ 200MM O.C. 1Omm Ø STIRRUPS SPACED
B4 300 600 2-D16MM CONT. RSB 2-D16MM CONT. RSB 2-D16MM CONT. RSB @ 3 - 0.05M, 3-0.10M, REST
PLAN 4-D20MM CONT. RSB 4-D20MM CONT. RSB 4-D20MM CONT. RSB
@ 0.15M O.C.

1 FOUNDATION PLAN 3-D20MM CONT. RSB 3-D20MM CONT. RSB 3-D20MM CONT. RSB
1:100MTS 1Omm Ø STIRRUPS SPACED
@ 3 - 0.05M, 3-0.10M, REST
RB1 300 600 2-D16MM CONT. RSB 2-D16MM CONT. RSB 2-D16MM CONT. RSB
@ 0.15M O.C.

3-D20MM CONT. RSB 3-D20MM CONT. RSB 3-D20MM CONT. RSB

2-D16MM CONT. RSB 2-D16MM CONT. RSB 2-D16MM CONT. RSB


1Omm Ø STIRRUPS SPACED
BASEMENT FLOOR LINE 250 400 2-D16MM CONT. RSB 2-D16MM CONT. RSB 2-D16MM CONT. RSB @ 3 - 0.05M, 3-0.10M, REST
NATURAL GRADE LINE RB2
@ 0.15M O.C.
2-D16MM CONT. RSB 2-D16MM CONT. RSB 2-D16MM CONT. RSB
0.50m.
0.30m.

4-D20MM CONT. RSB G60 @CORNERS 8-D16MM CONT. RSB G60 @CORNERS

0.30m.
2-D16MM CONT. RSB 2-D16MM CONT. RSB 2-D16MM CONT. RSB 1Omm Ø STIRRUPS SPACED
12-D16MM CONT. RSB G60

0.60m.
1 SET COLUMN TIES 10MM CONT.RSB G40 @ 3 - 0.05M, 3-0.10M, REST
3 SETS COLUMN TIES 10MM CONT.RSB G40 250 400
TO VERIFY

SPACED @ 2@50MM ,5 @ 100MM & REST @150MM RB @ 0.15M O.C.


SPACED @ 2@50MM ,5 @ 100MM & REST @150MM
C2 FROM FOUNDATION TO GROUND FLOOR
2-D16MM CONT. RSB 2-D16MM CONT. RSB 2-D16MM CONT. RSB
FROM FOUNDATION TO 4TH FLOOR

C1A 0.30m.
0.50m.
8-D16MM CONT. RSB G60 @CORNERS
8 BEAM SCHEDULE

0.30m.
4-D20MM CONT. RSB G60 @CORNERS 1 SET COLUMN TIES 10MM CONT.RSB G40
10-D16MM CONT. RSB G60
SPACED @ 2@50MM ,5 @ 100MM & REST @150MM 1:100MTS
0.60m.

1 SET COLUMN TIES 10MM CONT.RSB G40


C3 FROM GROUND FLOOR TO 4TH FLOOR
0.65m.

SPACED @ 2@50MM ,5 @ 100MM & REST @150MM


0.30m.
4TH FLOOR TO ROOF BEAM

FOUNDATION THICKNESS = 650MM C1B 6-D16MM CONT. RSB G60 @CORNERS

0.30m.
1 SET COLUMN TIES 10MM CONT.RSB G40
SPACED @ 2@50MM ,5 @ 100MM & REST @150MM

C4 FROM 4TH FLOOR TO ROOF BEAM

SECTION
7 FOUNDATION SECTION
1:50MTS

9 COLUMN DETAIL
1:100MTS

PROJECT TITLE: OWNER SHEET CONTENTS SHEET NO.:

PROPOSED 4-STOREY BUILDING AS SHOWN


MR. ELMER ATUD
SIGNATURE OVER PRINTED NAME S-01
PRC NO.: TIN NO.: PRC NO.: TIN NO.: CADD BY:
LOCATION: BRGY. ILOCANOS NORTE, CITY OF SAN FERNANDO, LA UNION
PTR NO.: DATE: PTR NO.: DATE/PLACE MOBILE NO.
GENERAL NOTES:
1.0 GENERAL: 3.0 MATERIALS: 4.0 FOUNDATION:
1.1 THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS 3.1 NORMAL WEIGHT CONCRETE 4.1 FOOTINGS WERE DESIGNED USING A MODULUS OF VERTICAL SUBGRADE REACTION OF
AT THE SITE AND SHALL NOTIFY THE ENGINEER OF DISCREPANCIES 12000KN/M2/m AT DEPTHS INDICATED IN THE DRAWING. SOIL INVESTIGATION
BETWEEN THE ACTUAL CONDITIONS AND INFORMATION SHOWN ON 3.1.1 COMPRESSIVE STRENGHT, f'c SHALL BE CARRIED PRIOR TO CONSTRUCTION AND THE STRUCTURAL ENGINEER
THE DRAWINGS BEFORE PROCEEDING WITH THE WORK. THIS SHALL SHALL BE FURNISHED A COPY OF THE SOIL'S REPORT.
INCLUDE THE LOCATION AND DIMENSION OF GROOVES, REGLETS, A. BEAMS, COLUMNS, FOOTINGS 28MPa (4000 psi) @ 28 days 5.5.1 BOTTOM OF FOOTINGS SHALL BE ON SOLID GROUND. ACTUAL DEPTH TO BE
SLEEVES, CURBS, OPENINGS, EMBEDED OR ATTACHED ITEMS ETC. B. SUSPENDED SLABS AND CONCRETE JOISTS 28MPa (4000 psi) @ 28 days APPROVED BY THE ENGINEER.
REFER TO ARCHITECTURAL ELECTRICAL, AND PLUMBING DRAWINGS. C. GROUND FLOOR SLAB ON FILL 11.03MPa (1600 psi) @ 28 days 5.5.2 SOIL BEARING CAPACITY SHALL BE INCREASED BY 33% WHEN IN COMBINATION
D. OTHERS NOT SPECIFIED 20.70MPa (3000 psi) @ 28 days WITH SEISMIC OR WIND LOAD.
1.2 DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALED DIMENSIONS
FROM PLANS, SECTIONS AND DETAILS. NOTES AND DETAILS ON 3.1.2 CONCRETE COVER OVER REINFORCING BARS SHALL BE AS FOLLOWS: 4.2 ALL COLUMN/WALL FOOTINGS SHALL REST ON 0.20 m. THICK WELL COMPACTED GRAVE
DRAWINGS SHALL TAKE PRECEDENCE OVER GENERAL NOTES AND BASE COURSE.
TYPICAL DETAILS. A. WALLS ABOVE GRADE 25MM
B. FORMED CONCRETE EXPOSED TO EARTH OR WEATHER 50MM 4.3 BACKFILL SHALL BE PACED IN 0.20 m. LAYERS AND EACH LAYER SHALL BE COMPACTED
1.3 THE CONTRACT STRUCTURAL DRAWINGS AND SPECIFICATIONS C. CONCRETE DIRECTLY POURED AGAINST EARTH 75MM TO 95% MAXIMUM DRY DENSITY
REPRESENT THE FINISHED STRUCTURE. THEY DO NOT INDICATE THE
METHODS OF CONSTRUCTION, UNLESS SO STATED. THE 3.1.3 BEFORE CONCRETE IS POURED, CHECK WITH ALL TRADES TO ENSURE PROPER 4.4 WHERE LOOSE/SOFT MATERIAL IS ENCOUNTERED AT DEPTH OF EMBEDMENT
CONTRACTOR SHALL PROVIDE ALL NECESSARY MEASURES TO PLACEMENT OF ALL OPENINGS, SLEEVES, CURBS, CONDUITS, ETC. RELATING TO EXCAVATE TO FIRM LAYER OR TO MAXIMUM OF 1.0 m. AND REPLACE LOOSE/SOFT
PROTECT THE STRUCTURES, ADJACENT PROPERTY, WORKMEN, AND THE WORK. MATERIALS UNDERNEATH THE FOOTING WITHIN THE FOOTING AREA PLUS 1/2 OF THE
OTHER PERSONS DURING ALL PHASES OF CONSTRUCTION. THE DEPTH OF THE EXCAVATED SOFT MATERIAL ON ALL SIDES WITH SELECTED
CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ENGINEER OF ANY 3.1.4 CONCRETE SHALL BE IN ITS FINAL POSITION W/O FLOWING. PLACING SHALL BE SAND/GRAVEL BACKFILL MATERIALS COMPACTED AS DESIRED BY ENGINEER.
CONDITION WHICH IN HIS OPINION MIGHT ENDANGER THE STABILITY DONE PREFERABLY WITH BUGGIES, BUCKETS OR WHEELBARROW, NO CHUTES
OF THE STRUCTURE OR CAUSES DISTRESS OF THE STRUCTURE. WILL BE ALLOWED EXCEPT TO TRANSFER CONCRETE FROM HOPPER TO
BUGGIES, WHEELBARROW OR BUCKETS.
1.4 CONSTRUCTION MATERIALS SHALL NOT BE STORED ON POURED
SLABS. IT IS THE GENERAL CONTRACTOR'S RESPONSIBILITY TO 3.1.5 NO DEPOSITING OF CONCRETE SHALL BE ALLOWED WITHOUT THE USE OF
ENSURE THAT THE SUB-CONTRACTOR'S ARE INFORMED AND DO NOT VIBRATORS UNLESS AUTHORIZED IN WRITING BY THE STRUCTURAL ENGINEER
VIOLATE THIS IMPORTANT REQUIREMENT. AND ONLY FOR UNUSUAL CONDITIONS WHERE VIBRATION IS EXTREMELY
DIFFICULT TO ACCOMPLISH.
1.5 THE CONTRACTOR SHALL PROVIDE TEMPORARY ERECTION BRACING
AND SHORING FOR ALL STRUCTURE MEMBERS AS REQUIRED FOR
STRUCTURE STABILITY DURING ALL PHASES OF CONSTRUCTION. 1
2
1.6 THE CONTRACTOR SHALL TAKE ALL STEPS NECESSARY TO ENSURE 3.2 REINFORCING BARS:
PROPER ALIGNMENT OF THE STRUCTURE AFTER THE INSTALLATION 3.2.1 REINFORCING BARS SHALL HAVE A MIN. YIELD STRENGTH,
OF ALL STRUCTURAL AND FINISH MATERIAL. FY = 415 MPa (Grade 60). DET. OF LIMITING SLOPE OF
ADJACENT FOOTINGS
1.7 TYPICAL DETAILS AND GENERAL NOTES APPLY TO ALL PARTS OF 3.2.2 ALL REINFORCING BARS SHALL BE CLEAN OF RUST, GREASE OR OTHER
THE JOB UNLESS OTHERWISE SHOWN ON THE DRAWINGS. MATERIALS THAT IMPAIR BOND. 5.0 CONSTRUCTION JOINTS: 6.0 MASONRY:

3.2.3 ALL REINFORCING BARS SHALL BE ACCURATELY AND SECURELY PLACED BEFORE 5.1 CONSTRUCTION JOINTS NOT INDICATED ON THE PLANS SHALL BE MADE SO AS 6.1 ALL NON BEARING TYPE CONCRETE BLOCKS SHALL HAVE A UNIT WEIGHT NOT TO
POURING CONCRETE OR APPLYING MORTAR GROUT. TO LEAST IMPAIR THE STRENGTH OF THE STRUCTURE AND SHALL BE SUBJECT EXCEED 80 PCF, MIN. COMPRESSIVE STRENGTH OF 350 PSI.
TO THE APPROVAL OF THE ENGINEER, EXCEPT SLAB ON GRADE.
2.0 STANDARDS AND REFERENCES: 3.2.4 LAPPED SPLICES SHALL BE STAGGERED WHERE POSSIBLE. 6.2 OPENING FOR DOORS, WINDOWS, AND OTHER GAPS ON CHB WALLS SHALL BE
THE FOLLOWING SHALL GOVERN THE DESIGN, FABRICATION, AND 5.2 UNLESS OTHERWISE SHOWN, SLAB ON GRADE SHALL HAVE CONTROL JOINTS AT PROVIDED WITH LINTEL BEAM OF THE SAME WIDTH AS THE CHB.
CONSTRUCTION OF THE PROJECT: 3.2.5 SHOP DRAWINGS FOR REINFORCEMENT SHALL BE SUBMITTED FOR APPROVAL OF 6.0 m. MAXIMUM CENTER TO CENTER.
THE STRUCTURAL ENGINEER PRIOR TO FABRICATION. POURING SHALL BE DONE 6.3 VERIFY ARCHITECTURAL AND OTHER RELATED PLANS FOR THE EXACT WALL
ONLY AFTER THE ENGINEER APPROVES THE REBAR WORKS. OPENING LOCATION.
3 mm.
2.1 AMERICAN CONCRETE INSTITUTE ( A C I ) PUBLICATIONS: SEWED JOINT W/ SEALANT
6.4 LINTEL BEAMS OR LINTEL BLOCKS SHALL BEAR AT LEAST 8 INCHES (200MM) ON
3.3 STRUCTURAL STEEL EACH SIDE OF MASONRY WALL OPENING.
ACI 318M - 08 BUILDING CODE REQUIREMENTS FOR STRUCTURAL T/2
CONCRETE 3.3.1 ALL STRUCTURAL STEEL SHALL HAVE A MINIMUM YIELD STRENGTH OF Fy = 248 T
MPA (36KSI) AND SHALL CONFORM TO ASTM A 36 SPECIFICATIONS T/2 6.5 BLOCK WALL REINFORCING BARS SHALL BE LAPPED A MINIMUM OF 30 BAR
2.2 AMERICAN INSTITUTE OF STEEL CONSTRUCTION ( A I S C ) DIAMETER WHERE SPLICED, HORIZONTAL / VERTICAL DOWELS FROM FOOTINGS
PUBLICATION, MANUAL OF STEEL CONSTRUCTION, 9TH EDITION. 3.3.2 ALL COLD FORMED STEEL SHALL HAVE A MINIMUM YIELD STRENGTH OF Fy = 230 COLUMN / WALLS OR SLAB SHALL EXTEND INTO THE BLOCK WALL A MINIMUM OF 30
MPA (33KSI). BAR DIAMETER OR A MINIMUM OF 400MM WHICHEVER IS LONGER AND DOWELS TO
100 mm. THK
2.3 AMERICAN IRON AND STEEL INSTITUTE ( A I S I ) PUBLICATION, COLD GRAVEL BASE MATCH VERTICAL REINFORCEMENTS OF WALL.
FORMED STEEL DESIGN MANUAL, 1983 EDITION. 3.3.3 NO STEEL SHALL BE FABRICATED OR ERECTED UNTIL SHOP DRAWINGS HAVE
BEEN APPROVED BY THE STRUCTURAL ENGINEER AND SHALL CONFORM IN WEAKENED PLANE JOINT 6.6 ALL CELLS CONTAINING REINFORCING BARS OR INSERTS SHALL BE SOLIDLY
2.4 NATIONAL STRUCTURAL CODE OF THE PHILIPPINES ( N S C P) , 2015 ACCORDANCE WITH THE AISC SPECIFICATIONS (9TH EDITION) AND CODE OF 50 FILLED WITH CONCRETE GROUT.
STANDARD PRACTICE AS AMENDED TO DATE. TOOLED EDGE

2.5 AMERICAN STANDARD FOR TESTING MATERIALS ( A S T M ) 6.7 PROVIDE STIFFENER COLUMN ON CHB WALL FOR 4M WALL HEIGHT
3.3.4 ALL SHOP AND FIELD WELDING SHALL BE IN ACCORDANCE WITH AWS D.1.1 - T/3
STANDARD SPECIFICATION. T
2000 AND PERFORMED BY QUALIFIED WELDERS. T/3

2.6 PHILIPPINE NATIONAL STANDARD ( P N S ) T/3


3.3.5 UNLESS INDICATED OTHERWISE, WELDING ELECTRODES SHALL BE E60XX.
2.7 A S E P HANDBOOK OF STRUCTURAL STEEL SHAPES & SECTIONS, MNIMUM THICKNESS OF WELD SHALL BE 4MM.
1994 100 mm. THK
3.3.6 ALL ANCHOR BOLTS/BOLTS/SCREWS SHALL CONFORM TO ASTM A307 GRAVEL BASE

2.9 A S C E 7-05 MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER SPECIFICATIONS.
STRUCTURES CONSTRUCTION JOINT
NOTES:
3.0 UNIFORM BUILDING CODE 1997 CONTROL JOINT CAN BE EITHER CONSTRUCTION JOINT
OR WEAKENED PLANE JOINT

PROJECT TITLE: OWNER SHEET CONTENTS SHEET NO.:

PROPOSED 4-STOREY BUILDING AS SHOWN


MR. ELMER ATUD
SIGNATURE OVER PRINTED NAME S-02
PRC NO.: TIN NO.: PRC NO.: TIN NO.: CADD BY:
LOCATION: BRGY. ILOCANOS NORTE, CITY OF SAN FERNANDO, LA UNION
PTR NO.: DATE: PTR NO.: DATE/PLACE MOBILE NO.

You might also like