Professional Documents
Culture Documents
040
FFL + 05.040
SSL + 05.500
FFL + 05.500
1 2 3 4 5 6 7 8
BALMOND STUDIO LONDON OFFICE
Unit 9, 190a New North Road, London N1 7BJ, UK
Tel: +44 20 7043 0651
wheel stop
BALMOND STUDIO COLOMBO OFFICE
Glennie Cottage, 78 Glennie Street Colombo-02, Sri Lanka
Tel: +94 11 2304476
CONDITIONS OF USE:
© Copyright Balmond Studio 2011.
wheel stop
The author asserts the right to be identified as such.
Documentation is to be used for the intended purpose only. Balmond
A Studio accepts no liability, however arising, for misuse of drawings
STAIRCASE SC2.08
and documents.
FFL + 03.000
2.02
CAR PARK
Drawings must be read in conjunction with all relevant Contract
057
5.02
SSL + 01.230
001
Documentation including Preliminaries, Particular Conditions,
General Conditions, Particular Specifications, General Specifications
and Drawings.
Any discrepancies between any drawings, specifications, documents,
etc., should be reported to the Engineer in accordance with the
Conditions of Contract.
The Contractor remains fully responsible for setting out the works.
Do not scale drawings. Use figured dimensions only. Dimensions
must be checked by the Contractor on site.
Core 2.7
wheel stop
CH
MS
John
wheel stop Keells
Group
ADÃO DA FONSECA
STAIRCASE SC2.09 engenheiros consultores
2.02
037
Core 2.8
Refer to building 5 package GET GESTÃO DE ENERGIA TÉRMICA, LDA.
Engenheiros Consultores
de
Alfredo Costa Pereira e Raul Vasconcelos Bessa
AZ76 Consultores
SC5.03 de Investimentos
5.02 e Engenharia, Lda
002
STAIRCASE SC2.07
2.02 wheel stop
064
KEY PLAN
6
4 5
2
3 1
STORAGE
2.02
048
KEY ELEVATION
SPECIALIST INTERIORS PACKAGE SPECIALIST INTERIORS PACKAGE
REFER TO I-210101 REFER TO I-211101
D
CORRIDOR STORAGE
2.02 2.02
049 050
FFL + 05.167
Smoke curtain
Smoke curtain
Smoke curtain
Smoke curtain
Smoke curtain
PUBLIC WC SERVICE /
FIRE FIGHTING LIFT
2.02
519 -01.17
STAIRCASE FSL2.05 FSL2.06
PLANT ROOM SC2.03 SERVICE / SERVICE /
FIRE FIGHTING LIFT FIRE FIGHTING LIFT
2.02
041
Smoke curtain
Smoke curtain
Smoke curtain
Smoke curtain
Smoke curtain
521
Core 2.11
TD HD TD
PUBLIC WC
Smoke curtain
Smoke curtain
Smoke curtain
Smoke curtain
Smoke curtain
Fire curtain with egress door Fire curtain with egress door Fire curtain with egress door
ENTERTAINMENT LOBBY
1.02 +05.150
501 +01.500
CORRIDOR
3.02
SL2.07
HOTEL LUGGAGE / LINEN 022
-2.17-5.0
PL1.01
F 07.07.2015 SPECIALIST INTERIORS VMN FSG
RETAIL
FFL + 05.167 GUEST LIFT
-4.5-20.0
E 07.02.2015 INSTALLATION DETAILS CVR FSG
LUGGAGE STORAGE SSL + 05.067
3.02 LANDSCAPE PACKAGE
025 Rev Date Issue Dwn Ckd
REFER TO L-111131
STATUS
PL1.02
RETAIL
SPECIALIST INTERIORS PACKAGE
FOR CONSTRUCTION
GUEST LIFT
-4.5-20.0
REFER TO I-217101
+04.910 +04.910 +04.910
SSL + 05.067
WATERFRONT
SSL + 04.833 SSL + 04.833 3.02
026 PL1.04
RETAIL
GUEST LIFT
COLOMBO
-4.5-20.0 +05.150 +05.100 +05.000 +04.910 +05.140 +05.140 +04.910
3.02
027
SRI LANKA
SERVICE /
FIRE FIGHTING LIFT
SERVICE /
FIRE FIGHTING LIFT
3.02
016
FFL + 04.833
G SSL + 04.783
PL1.05
RETAIL
GUEST LIFT DISCIPLINE
-4.5-20.0
LIFT SHAFT
LIFT SHAFT
3.02
018 1.02
008 ELECTRICAL WORKS
ES1.3b
3.02
INTERVIEW ROOM 3
1.02
Core 1.1 +04.910 +04.910 +04.910 DRAWING TITLE
028 002
INTERVIEW ROOM 1
+05.000 +05.000 +05.000
LEVEL 2 PLAN
FFL + 04.833
SSL + 04.783
1.02
004
STAIRCASE SC2.06
2.02
038
+05.100 +05.100 +05.100
.
+05.150 +05.150 +05.150 +05.150
Date Drawing No Revision
Scale
E-210109 L
TAXI DRIVER RELAX ROOM LIFT LOBBY
TECHNICAL AREA
50 DRIVERS FOR WATERFALL 1.02
FFL + 04.833 3.02
029
1.02
009
+05.070 +05.070 502 SPECIALIST INTERIORS PACKAGE 1:200 @ A1
SSL + 04.833
REFER TO I-115001 BS Job No
FFL + 05.167
FFL + 04.880 2.02
SSL + 05.067
SSL + 04.880
039 1090
FFL + 04.833 CAD File Name
SSL + 04.883
H E-210109-L.dwg
CORRIDOR
1.02
PLANT ROOM
1.02
PL1.08
EXHIBITION
c
GUEST LIFT
PLANT ROOM 011 012 5.0-34.5
STAIRCASE
1.02
1.02 010
LIFT SHAFT
005 +04.833 +04.833 1.02
013
Core 1.2
H1 SCALE: 1:200@A1
www.balmondstudio.com
Registered in England & Wales No. 7225351