Professional Documents
Culture Documents
_____________________
THESE DRAWINGS HAVE BEEN AUTOMATICALLY GENERATED FROM INFORMATION THAT IS BASED ONLY ON
CALCULATED STRENGTH REQUIREMENTS. THE DRAWING SHEETS ARE A REPRESENTATION OF THE DESIGN OUTPUT
IN A SCHEMATIC FORM AND ARE NOT FOR CONSTRUCTION. ALL DETAILS SHOULD BE REVIEWED FOR COMPLIANCE
WITH LOCAL DETAILING CODES AND OTHER REQUIREMENTS.
THE INFORMATION ON THESE DRAWINGS MUST BE CHECKED BY A QUALIFIED AND EXPERIENCED ENGINEER. THE
ENGINEER MUST INDEPENDENTLY VERIFY THE RESULTS AND TAKE PROFESSIONAL RESPONSIBILITY FOR THE
FINAL INFORMATION THAT IS PRESENTED.
CONSIDERABLE TIME, EFFORT AND EXPENSE HAVE GONE INTO THE DEVELOPMENT AND TESTING OF THIS
SOFTWARE. HOWEVER, THE USER ACCEPTS AND UNDERSTANDS THAT NO WARRANTY IS EXPRESSED OR IMPLIED BY
THE DEVELOPERS OR THE DISTRIBUTORS ON THE ACCURACY OR THE RELIABILITY OF THIS PRODUCT.
LIST OF DRAWINGS
S-04 2CB2:ELEVATION
NO DESCRIPTION DATE
DRAWING
LIST OF DRAWINGS
STRUCTURE
PROJECT
CSIDETAIL
CLIENT
CSIDETAIL USER
CONSULTANT
VV
DATE
DESIGNED BY NA
CHECKED BY AH
S-01
SCALE
TIES ZONE A TIES ZONE C
90 DEG HOOK
TYPICAL LAP
TIES ZONE B
H3
TYPICAL LAP
TIES ZONE B
H2
TYPICAL LAP
TIES ZONE B
Ln
H1
BEAM HEIGHT
L1 L2 DRAWING
B A D Width
STANDARD DETAILS
d
h
G F H
STRUCTURE
Depth
NOTES:
1. SEE BEAM SCHEDULE FOR STIRRUP TYPE AND SPACING.
DETAILING OF SLABS AND BEAMS
2. ZONE A LENGTH SHALL BE TWICE THE BEAM DEPTH, d.
3. THE FIRST STIRRUP IN ZONE A SHALL BE LOCATED 50mm MAXIMUM FROM THE FACE OF THE SUPPORT.
4. LAP SPLICES SHALL NOT BE LOCATED WITHIN THE BEAM/COLUMN JOINT, NOR WITHIN A DISTANCE OF 2H.
5. LAP SPLICE LENGTH SHALL NOT BE LESS THAN 300mm.
PROJECT
Typical Concrete Beam Elevation (Seismic) - SS Beam Section-A (Seismic) Concrete Column Typical Elevation (Seismic) Column Section-A
CSIDETAIL
CLIENT
CSIDETAIL USER
CONSULTANT
VV
DATE
DESIGNED BY NA
CHECKED BY AH
S-02
SCALE
A B A B
6000 mm 6000 mm
2CB1S1 1CB1S1
2
2
6000 mm
6000 mm
2CB2S1 1CB2S1
2CB1S1
2CB1S1
1CB1S1
1CB1S1
2CB1S1 1CB1S1
1
1
Concrete Beam Layout - Story2 (EL. 7000 mm) Concrete Beam Layout - Story1 (EL. 4000 mm) NO DESCRIPTION DATE
(Scale = 1:50) (Scale = 1:50)
0 NEW DRAWING GENERATED 3/06/2021
STRUCTURE
PROJECT
CSIDETAIL
325 mm
5950 mm
2-14A
CLIENT
2-14A
10@100 mm 10@225 mm 10@100 mm
CSIDETAIL USER
3-20F
500 mm
CONSULTANT
325 mm 325 mm
10@100 mm
S-03
SCALE
A
A
325 mm
5950 mm 5950 mm
2-14A 2-20A
2-14A
10@100 mm 10@225 mm 10@100 mm 10@100 mm 10@225 mm 10@100 mm
3-20F 3-20F
500 mm
325 mm 325 mm
10@100 mm
6000 mm 6000 mm
3-20F
250 mm
A B
6000 mm
CC1 CC1
2
NO DESCRIPTION DATE
6000 mm
A
5950 mm
2-14A
DRAWING
2-20A 2-14A
10@100 mm 10@225 mm 10@100 mm
2CB2:ELEVATION
CC1 CC1
1
3-20F
500 mm
500 mm
STRUCTURE
10@100 mm 10@100 mm
1CB1:Section A 1CB2:Elevation 1CB2:Section A Concrete Column Layout - Base (EL. 0 mm) CSIDETAIL
(Scale = 1:50)
(Scale = 1:15) (Scale = 1:25) (Scale = 1:15)
CLIENT
CSIDETAIL USER
CONSULTANT
VV
DATE
DESIGNED BY NA
CHECKED BY AH
S-04
SCALE
STORY2
(EL. 7000 MM)
10@100 mm 10@100 mm
3000 mm
10@150 mm
10@100 mm
STORY1
(EL. 4000 MM)
Concrete Column Schedule
10@100 mm 10@100 mm
CC1
REINFORCING
COLUMN SIZE
TIES ZONE-A
TIES ZONE-B
TIES ZONE-C
SECTION
12-16
4000 mm
Story2
10@150 mm
375 mm
2-16
Story1 NO DESCRIPTION DATE
16
0 NEW DRAWING GENERATED 3/06/2021
375 MMX375 MM
12-16 (1,406.45)
10@100 MM
10@150 MM
10@150 MM
A
375 mm
3-16
3-16
BILL OF MATERIALS: CONCRETE COLUMN
10@100 mm
Base REBAR QUANTITIES: CONCRETE COLUMN
SR. NO. ITEM QUANTITY UNIT
STRUCTURE
PROJECT
CSIDETAIL
CLIENT
CSIDETAIL USER
CONSULTANT
VV
DATE
DESIGNED BY NA
CHECKED BY AH
S-05
SCALE