You are on page 1of 4

Industrial Generator Set Accessories

Subbase Diesel Fuel Tanks

Double-Wall Subbase
Fuel Tanks (UL Listed)
Applicable to the following:
650--2250REOZDC
Secondary Containment (SC) Tank
D The above-ground rectangular secondary
containment tank mounts directly to the generator
set, below the generator set skid (subbase).
D Both the inner and outer UL-listed tanks have
emergency relief vents.
D The containment tank’s double-layer construction
protects against fuel leaks or ruptures. The inner
(primary) tank is sealed inside the outer (secondary)
tank. The outer tank contains the fuel if the inner
tank leaks or ruptures.
D The subbase fuel tanks are available in two styles.
Subbase Fuel Tank with Solid Mounting d Fuel tanks with rubber mounting for generator
for Generator Sets with Vibration Isolation sets with solid mounting to the skid.
Mounting to the Skid d Fuel tanks with solid mounting for generator set
with integrated vibration mounting to the skid.

Standard Features
D Heavy-gauge construction
D Emergency pressure-relief vent inner and outer
tanks
D Lockable fill cap and riser, 2 in. NPT
D Low fuel level switch for controller alarm
D Mechanical fuel gauge
D Normal vent with riser and mushroom cap
D Fuel supply and fuel return openings
D Basin drain
D Float fitting for pump control for fuel transfer system
model
D Overflow opening for fuel transfer system model

Subbase Fuel Tank with Rubber Mounting for


Generator Sets with Solid Mounting to the Skid

G6-85 1/07
Fuel Tank Features

GENERATOR 1 2 3
Fault 4

ALARM
Normal Silence 5 6 7

1 4 9 10

View A -- A

11
A A

ADV-7247-

1. 2 in. NPT for overflow to main tank


(bushed down to 1 in. and plugged)
2. 2 in. NPT for low level switch (set for 50% full silicone packed)
3. 2 in. NPT addition fitting for optional accessory
4. Emergency fitting per NFPA 30 with vent caps
5. 2 in. NPT for fuel inlet for supply pump
(bushed down to 1 in. and plugged)
6. 2 in. NPT fitting for removable engine supply diptube
(3/4 in. NPT female with check valve)
GM38833-/A-292887
7. 2 in. NPT fitting for removable fuel return diptube
(3/4 in. NPT female)
3 2 8. 2 in. NPT normal vent with mushroom cap
(1 1/4 in. NPT for tanks less than 2500 gal.)
9. 2 in. NPT fuel fill fitting with lockable cap
1. Inner tank leak alarm kit 10. 2 in. NPT fuel level gauge fitting with direct reading
2. Emergency pressure relief vent inner tank mechanical gauge
3. 1/2 in. NPT for leak detection switch 11. 1/2 in. NPT for fuel in basin switch

Figure 1 Inner Tank Leak Alarm Kit Figure 2 Fuel Tank Fittings

Fuel Tank Accessories


D Inner tank leak alarm kit (see Figure 1). D Above ground 19 L (5 gal.) fill/spill container for fuel overfill
spills during fill up; external mount only with weather/sound
D High fuel level alarm switch (90% full).
enclosure with internal silencer.

G6-85 1/07
Fuel Tank Weights and Dimensions
Subbase Fuel Tank with Solid Mounting
for Generator Sets with Vibration Isolation Mounting to the Skid
Est. Fuel
Supply, Hours
Capacity, Length, Width, Height, Weight, at 60 Hz with
Model Kit No. L (gal.) mm (in.) mm (in.) mm (in.) kg (lb.) Full Load
GM40830-KP1/TP1 2407 (636) 457 (18) 1476 (3255) 12
3681 (145)
GM40830-KP2/TP2 4834 (1277) 1919 (4230) 24
650/750REOZDC all 1930 (76)
alternators except GM40830-KP3/TP3 7204 (1903) 5106 (210) 2562 (5648) 36
5M4030
M 030 and d 5M4272
M 2 2 914 (36)
GM40830-KP4/TP4 9721 (2568) 6789 (267) 3331 (7343) 48
GM40830-KP5/TP5 14400 (3804) 7798 (307) 2413 (95) 4392 (9682) 72
GM40830-KP6/TP6 2407 (636) 457 (18) 1476 (3255) 12
3681 (145)
GM40830-KP7/TP7 4834 (1277) 1919 (4230) 24
650REOZDC 5M4030 1930 (76)
and 5M4272
5 alternators GM40830-KP8/TP8 7204 (1903) 5106 (201) 2562 (5648) 36
only
l 914 (36)
GM40830-KP9/TP9 9721 (2568) 6789 (267) 3331 (7343) 48
GM40830-KP10/TP10 14400 (3804) 7798 (307) 2413 (95) 4392 (9682) 72
900/1000REOZDC all GM40830-KP11/TP11 3384 (894) 457 (18) 1966 (4335) 12
4239 (167)
alternators except GM40830-KP12/TP12 6568 (1735) 2402 (5296) 24
5M4036 5M4038,
5M4036, 5M4038 and 2286 (90)
5M4168 with 40C GM40830-KP13/TP13 9747 (2575) 5690 (224) 914 (36) 3220 (7099) 36
radiator only GM40830-KP14/TP14 12973 (3427) 7468 (294) 4072 (8978) 48
GM40830-KP15/TP15 3384 (894) 457 (18) 1966 (4335) 12
900REOZDC 5M4036,
5M4036 4239 (107)
5M4038, and 5M4168 GM40830-KP16/TP16 6568 (1735) 2402 (5296) 24
2286 (90)
alternators only
y with GM40830-KP17/TP17 9747 (2575) 5690 (224) 914 (36) 3220 (7099) 36
40C radiator only
GM40830-KP18/TP18 12973 (3427) 7468 (294) 4072 (8978) 48
GM49734-KP15/TP15 5288 (1397) 4938 (194) 2285 (90) 610 (24) 2401 (5293) 12
1250REOZDC
GM49734-KP16/TP16 10288 (2718) 4938 (194) 2743 (108) 914 (36) 3251 (7167) 24
1500REOZDC all GM49734-KP13/TP13 5197 (1373) 5294 (208) 2285 (90) 610 (24) 2474 (5454) 12
alternators except
7M4050 GM49734-KP14/TP14 10130 (2676) 5294 (208) 2540 (100) 914 (36) 3232 (7125) 24

1500REOZDC GM49734-KP15/TP15 12973 (3427) 4938 (194) 2285 (90) 610 (24) 2401 (5293) 12
alternators 7M4050 only GM49734-KP16/TP16 10288 (2718) 4938 (194) 2743 (108) 914 (36) 3251 (7167) 24
GM49734-KP11/TP11 5784 (1528) 5271 (208) 2285 (90) 610 (24) 2531 (5580) 12
1750REOZDC
GM49734-KP12/TP12 11281 (2980) 5271 (208) 2845 (112) 914 (36) 3790 (8355) 24

G6-85 1/07
KOHLER CO., Kohler, Wisconsin 53044 USA Kohler Power Systems
Phone 920-565-3381, Fax 920-459-1646 Asia Pacific Headquarters
For the nearest sales and service outlet in the 7 Jurong Pier Road
US and Canada, phone 1-800-544-2444 Singapore 619159
KohlerPowerSystems.com Phone (65) 6264-6422, Fax (65) 6264-6455

Subbase Fuel Tank with Rubber Mounting for Generator Sets with Solid Mounting to Skid
Est. Fuel
Supply, Hours
Capacity, Length, Width, Height, Weight, at 60 Hz with
Model Kit No. L (gal.) mm (in.) mm (in.) mm (in.) kg (lb.) Full Load
GM40830-KP19/TP19 2407 (636) 457 (18) 1476 (3255) 12
3681 (145)
GM40830-KP20/TP20 4834 (1277) 1919 (4230) 24
650/750REOZDC all 1930 (76)
alternators except GM40830-KP21/TP21 7204 (1903) 5106 (210) 2562 (5648) 36
5M4030
M 030 and d 5M4272
M 2 2 914 (36)
GM40830-KP22/TP22 9721 (2568) 6789 (267) 3331 (7343) 48
GM40830-KP23/TP23 14400 (3804) 7798 (307) 2413 (95) 4392 (9682) 72
GM40830-KP24/TP24 2407 (636) 457 (18) 1476 (3255) 12
3681 (145)
GM40830-KP25/TP25 4834 (1277) 1919 (4230) 24
650REOZDC 5M4030 1930 (76)
and 5M4272
5 alternators GM40830-KP26/TP26 7204 (1903) 5106 (201) 2562 (5648) 36
only
l 914 (36)
GM40830-KP27/TP27 9721 (2568) 6789 (267) 3331 (7343) 48
GM40830-KP28/TP28 14400 (3804) 7798 (307) 2413 (95) 4392 (9682) 72
900/1000REOZDC all GM40830-KP29/TP29 3384 (894) 457 (18) 1966 (4335) 12
4239 (167)
alternators except GM40830-KP30/TP30 6568 (1735) 2402 (5296) 24
5M4036 5M4038,
5M4036, 5M4038 and 2286 (90)
5M4168 with 40C GM40830-KP31/TP31 9747 (2575) 5690 (224) 914 (36) 3220 (7099) 36
radiator only GM40830-KP32/TP32 12973 (3427) 7468 (294) 4072 (8978) 48
GM40830-KP33/TP33 3384 (894) 457 (18) 1966 (4335) 12
900REOZDC 5M4036,
5M4036 4239 (167)
5M4038, and 5M4168 GM40830-KP34/TP34 6568 (1735) 2402 (5296) 24
2286 (90)
alternators only
y with GM40830-KP35/TP35 9747 (2575) 5690 (224) 914 (36) 3220 (7099) 36
40C radiator only
GM40830-KP36/TP36 12973 (3427) 7468 (294) 4072 (8978) 48
GM49734-KP9/TP9 5288 (1397) 4938 (194) 2285 (90) 610 (24) 2401 (5293) 12
1250REOZDC
GM49734-KP10/TP10 10288 (2718) 4938 (194) 2743 (108) 914 (36) 3251 (7167) 24
1500REOZDC all GM49734-KP7/TP7 5197 (1373) 5294 (208) 2285 (90) 610 (24) 2474 (5454) 12
alternators except
7M4050 GM49734-KP8/TP8 10130 (2676) 5294 (208) 2540 (100) 914 (36) 3232 (7125) 24

1500REOZDC GM49734-KP9/TP9 5288 (1397) 4938 (194) 2285 (90) 610 (24) 2401 (5293) 12
alternators 7M4050 only GM49734-KP10/TP10 10288 (2718) 4938 (194) 2743 (108) 914 (36) 3251 (7167) 24
GM49734-KP5/TP5 5784 (1528) 5217 (205) 2285 (90) 610 (24) 2531 (5580) 12
1750REOZDC
GM49734-KP6/TP6 11281 (2980) 5217 (205) 2845 (112) 914 (36) 3490 (7694) 24
GM49734-KP3 6935 (1832) 5690 (224) 2815 (111) 610 (24) 3102 (6839) 12
2000REOZDC
GM49734-KP4 13552 (3580) 5690 (224) 3099 (122) 914 (36) 4077 (8988) 24
GM49734-KP1 7465 (1972) 5738 (226) 2815 (111) 610 (24) 3180 (7011) 12
2250REOZDC
GM49734-KP2 14945 (3948) 6401 (252) 3023 (119) 914 (36) 4382 (9661) 24

DISTRIBUTED BY:

Availability is subject to change without notice. Kohler Co. reserves the


right to change the design or specifications without notice and without any
obligation or liability whatsoever. Contact your local Kohlerr generator
distributor for availability. © 2007 by Kohler Co. All rights reserved.

G6-85 1/07

You might also like